advertisement
▼
Scroll to page 2
GB Wolf ATEX LED Torch Range Operation and Maintenance Instructions – please retain TR-40 EN IEC 60079:– EC Declaration of Conformity The Wolf ATEX LED Torch Range meets all relevant provisions of the 94/9/EC (ATEX Equipment) Directive by virtue of the issued EC type examination certificate, demonstrating compliance with all relevant harmonised standards and essential health and safety requirements. Wolf ATEX LED Torches are self contained primary cell powered torches with high power LED light sources, moulded in high impact strength plastic. The TR-40 and TR-40+ are approved as Group l, M2 equipment for mining applications and Group II, Category 2 equipment for use in Zone 1 & 2 potentially explosive gases, vapours, mists and dusts where approval code temperature class of specific cells apply. The TR-45 is approved as Group l, M1 equipment for mining applications and Group ll, Category 1 equipment for use in Zone 0, 1 & 2 potentially explosive gases, vapours and mists, where approval code temperature class of specific cells apply. Do not open torch in Ex Area. If replacing TP-288 the switch must be in the off position to prevent damage to the switch contact. Do not mix cells, immediately remove used cells to avoid leakage. Do not use rechargeable cells. Damaged equipment should be repaired before further use. When in use ensure lens ring and end cap are screwed up tightly at all times. TR-40/TR-40+ Zone 1 LED: I M2/II 2 GD Ex ib I/IIC T4/T3 tD A21 IP67 T85°C (Temperature ambient -20°C to +40°C) TR-45 Zone 0 LED: I M1/II 1 G Ex ia I/IIC T4/T3 IP67 (Temperature ambient -20°C to +40°C) TP-343 R-393 TP-317 TP-288 Wolf Safety Lamp Company TP-448 TP-284 Zone 1 0% TP-260 TP-282 R-291 TR-40+ ATEX approved for explosive gas and dust atmospheres TP-343 R-393 TP-317 TR-40/TR-45 TP-288 T TP-448 TP-284 Zone 1 100% Ingress protection level: IP67 to EN60529:1992 Alex Jackson – Technical Director Wolf Safety Lamp Company Ltd Use only genuine Wolf replacement parts The Wolf Safety Lamp Co. Ltd has a policy of continuous product improvement. Changes in design details may be made without prior notice. ~ 40% ~ 30% 100% ~ 20% CAUTION R-337 Zone 0 R-393 TP-318 TP-288 ~ 8hrs 0hrs TP-286 Zone 0 TP-448 ~ 72hrs ~ 40hrs HOT TP-260 TP-282 R-291 TR-40+ EC Type Examination Certificate: Baseefa07ATEX0091 The product is CE marked showing compliance with all relevant EC directives. 100% TP-260 TP-280 R-291 TR-45 Notified Body: Baseefa Ltd., Rockhead Business Park, Staden Lane, Buxton, SK17 9RZ, UK. Notified Body No. 1180 Harmonised standards applied: EN60079-0:2006(+EN60079-0:2004), EN60079-11:2007(+EN50020:2002), EN61241-0:2006, EN61241-1:2004 WOLF ATEX LED SAFETY TORCH 100% Wolf ATEX LED Torch – Spare Parts List IECEx Scheme Approval Wolf Part No. Cert Number: IECEx BAS 06.0089 Models: TR-40/TR-40+ o Code: Ex ib I/IIC T4/T3 tD A21 IP67 T85 C R-393 TP-317 TP-318 TP-288 TP-284 TP-286 TP-343 R-337 TP-448 R-291 TP-282 TP-280 TP-260 4x AA Wolf part no. TP-295 Models TR-45 Code: Ex ia l/llC T4/T3 IP67 T Class T4 IEC Standards Applied: IEC 60079-0:2004, IEC 60079-11:1999, IEC 61241-0:2004, IEC 61241-1:2004, LR6/AA Alkaline cells Duracell Procell, Duracell Plus, Energizer Industrial, Energizer Ultra + Ingress protection level: IP67 to IEC 60529:2001 Use only cell types as specified in instructions. R6 Zinc Cells T3 TP-295 TR-40 – – – – TR-40+ – – – – TR45 – – – – 100% ~ 40% ~ 30% ~ 20% Description Lens ring Lens Glass lens Heatsink LED Assembly TR-40 Torch body Assembly Zone 1 TR-45 Torch body Assembly Zone 0 Clip moulding Clip moulding Zone 0 Base ‘o’ seal End cap assembly Primary cell cassette Primary cell cassette with indicator Wrist strap & ring LR6/AA Primary Cell - pack of 4 0hrs ~ 8hrs ~ 40hrs ~ 72hrs OPERATION AND MAINTENANCE INSTRUCTIONS NL Wolf ATEX LED Serie Zaklampen Bediening en Onderhoudsvoorschriften – goed bewaren a.u.b. F Gamme de lampes torches ATEX à LED Wolf Instructions de fonctionnement et d’entretien – A conserver D Wolf ATEX LED Taschenlampen Gebrauchs- und Wartungshinweise – bitte aufbewahren – vor Gebrauch lesen GR I Gamma torce Wolf ATEX LED Istruzioni per l’uso e la manutenzione – da conservare PL P Gama de Lanternas Wolf ATEX LED Instruções de Funcionamento e Manutenção – por favor guarde este folheto E Línea de lámparas LED Wolf ATEX Instrucciones de funcionamiento y mantenimiento – Consérvelas DK Wolf ATEX LED-lygteserie Betjeningsog vedligeholdelsesinstruktioner – skal opbevares NO Wolf ATEX LED-lykt Drifts- og vedlikeholdsveileding – vennligst oppbevar EG Verklaring van Overeenstemming Déclaration de conformité CE EG Konformitätserklärung Dichiarazione di conformità CE Declaração de Conformidade CE Declaración de conformidad de la CE EU-overholdelseserklæring EU-samsvarseklæring De Wolf ATEX LED Serie Zaklampen voldoet aan alle relevante voorwaarden van de 94/9/EG (ATEXapparatuur) Richtlijn ingevolge de afgegeven EG-typeverklaring, waarmee aan alle relevante geharmoniseerde normen en essentiële gezondheidsen veiligheidseisen tegemoet gekomen wordt. Les lampes torches à LED ATEX satisfont toutes les dispositions de la directive 94/9/CE (équipement ATEX) en vertu du certificat de contrôle type CE publié, démontrant la conformité avec toutes les normes harmonisées et toutes les exigences essentielles d’hygiène et de sécurité. Die Wolf ATEX LED Taschenlampen erfüllen alle relevanten Anforderungen der 94/9/EG (ATEX Geräte) Richtlinie, belegt durch die ausgestellte EGBaumusterprüfbescheinigung, und dadurch auch die relevanten harmonisierten Normen und grundlegenden Sicherheits- und Gesundheitsanforderungen. La gamma di torce Wolf ATEX LED è conforme a tutti i requisiti indicati nella direttiva 94/9/EC (Dispositivi ATEX) secondo il certificato d’esame di tipo CE emesso a dimostrazione della conformità del prodotto con tutte le norme armonizzate relative e i requisiti fondamentali relativi alla salute e alla sicurezza. A Gama de Lanternas Wolf ATEX LED está em conformidade com todas as disposições relevantes da Directiva 94/9/CE (Equipamento ATEX) em virtude da emissão do certificado de exame CE de tipo, demonstrando cumprimento com todas as normas harmonizadas relevantes e requisitos essenciais de saúde e segurança. La línea de lámparas LED ATEX de Wolf cumple con todas las disposiciones pertinentes de la Directiva 94/9/EC (equipos ATEX) en virtud del certificado de examen del tipo CE emitido, que demuestra el cumplimiento con todas las normativas armonizadas y los requisitos esenciales sobre seguridad e higiene. Wolf ATEX LED-lygteserien overholder alle relevante bestemmelser i 94/9/EC (ATEX-udstyr) direktivet med hensyn til den udgivne EC-undersøgelsescertifikat, der angiver overholdelse af alle relevante harmoniserede standarder og essentielle sundheds- og sikkerhedskrav. Wolf ATEX LED-oppladbar lykt tilfredsstiller alle gjeldende retningslinjer i 94/9/EC-direktivet for eksplosive atmosfærer (ATEX-utstyr), i kraft av det utstedte EU-typegodkjenningssertifikat, og er i overensstemmelse med alle gjeldende harmoniserte standarder og essensielle helse- og sikkerhetskrav. Wolf ATEX LED Zaklampen zijn onafhankelijke, door primaire elementen gevoede zaklampen met sterke LEDlichtbronnen, gevormd in sterk schokbestendig plastic. De TR-40 en de TR-40+ zijn goedgekeurd als Groep l, M2 materiaal voor gebruik in mijnen en Groep II, Categorie 2 materiaal voor gebruik in Zone 1 & 2 potentieel explosief gas, damp, nevel en stof, waarvoor de goedgekeurde temperatuurklasse voor specifieke batterijen geldt. De TR45 is goedgekeurd als Groep l, M1 materiaal voor gebruik in mijnen en Groep II, Categorie 1 materiaal voor gebruik in Zone 0, 1 & 2 potentieel explosief gas, damp en nevel, waarvoor de goedgekeurde temperatuurklasse voor specifieke batterijen geldt. Les lampes torches à LED ATEX Wolf sont des lampes torches autonomes à piles, moulées en plastique à résistance élevée aux chocs, avec LED de forte puissance. Les modèles TR-40 et TR-40+ sont certifiés comme équipement de groupe l, comme équipement de catégorie M2 dans les mines et comme équipement de groupe II, Catégorie 2 pour l’utilisation en zones 1 & 2 pouvant contenir des gaz, des vapeurs, de la buée et des poussières explosifs, et où la classe de température des piles spécifiques l’autorise. Le modèle TR-45 est certifié comme équipement de groupe l, comme équipement de catégorie M1 dans les mines et comme équipement de groupe ll, Catégorie 1 pour l’utilisation en zones 0, 1 & 2 pouvant contenir des gaz, des vapeurs et de la buée explosifs, et où la classe de température des piles spécifiques l’autorise Die Wolf ATEX Taschenlampen sind autarke, in hochschlagzähem Kunststoff gekapselte Taschenlampen, die mit Einwegbatterien als starke LED-Lichtquellen betrieben werden. Die TR-40 und TR40+ sind gemäß Apparategruppe I, Kategorie M2 für den Einsatz im Bergbau zugelassen, wo Grubengas oder brennbare Stäube auftreten können, und gemäß Apparategruppe II, Kategorie 2 für den Einsatz in potentiell explosionsgefährdeten Atmosphären (Zone 1 und Zone 2), wo für Batterien Temperaturklassen festgeschrieben sind. Die TR-45 ist gemäß Apparategruppe I, Kategorie M1 für den Einsatz im Bergbau zugelassen, wo Grubengas oder brennbare Stäube auftreten können, und gemäß Apparategruppe II, Kategorie 1 für den Einsatz in potentiell explosionsgefährdeten Atmosphären (Zone 0, 1 und 2), wo für Batterien Temperaturklassen festgeschrieben sind. Le torce Wolf ATEX LED sono torce autonome dotate di sorgenti luminose a LED ad elevata potenza, con corpo in plastica ad alta resistenza. I modelli TR-40 e TR-40+ sono approvati quali dispositivi appartenenti al Gruppo l, dispositivi M2 per uso minerario e Gruppo II, Categoria 2 per l’uso in Zone 1 e 2 per gas, vapori, nebbie e polveri potenzialmente esplosivi laddove lo permetta la temperatura di classe delle pile specifiche. Il modello TR-45 è approvato quale dispositivo appartenente al Gruppo l, dispositivi M1 per uso minerario e Gruppo II, Categoria 1 per l’uso in Zone 0, 1 e 2 per gas, vapori, e nebbie potenzialmente esplosivi laddove lo permetta la temperatura di classe delle pile specifiche. As Lanternas Wolf ATEX LED são lanternas que funcionam com uma pilha primária incorporada, com fontes de luz LED de alta potência, sendo o corpo das lanternas moldadas em plástico resistente a fortes impactos. As lanternas TR-40 e TR-40+ foram aprovadas como equipamento do Grupo l, M2 para utilização em minas, e equipamento do Grupo II, Categoria 2 para utilização em Zonas 1 & 2 de gases, vapores, neblinas ou poeiras potencialmente explosivas, sendo aplicável a aprovação do código para uma temperatura de classe para pilhas específicas. A lanterna TR-45 foi aprovada como equipamento do Grupo l, M1 para utilização em minas e equipamento do Grupo ll, Categoria 1 para utilização em Zonas 0, 1 & 2 de gases, vapores e neblinas potencialmente explosivas, sendo aplicável a aplicação do código para uma temperatura de classe para pilhas específicas. Las Lámparas LED ATEX de Wolf son dispositivos autónomos con alimentación principal por pilas, con fuentes de iluminación LED de alta potencia moldeadas en plástico de alta resistencia. Los modelos TR-40 y TR-40+ están aprobados como equipos del Grupo l, M2 equipos para aplicaciones en minería y Grupo II, categoría 2 para su uso en Zonas 1 y 2 con gases, vapores, niebla y polvos potencialmente explosivos en las que se aplican un código de homologación de temperatura específico de las baterías. El modelo TR-45 están aprobados como equipos del Grupo l, M2 equipos para aplicaciones en minería y Grupo II, categoría 1 para su uso en Zonas 0, 1 y 2 con gases, vapores y niebla potencialmente explosivos en las que se aplican un código de homologación de temperatura específico de las baterías. De zaklamp niet in een explosieve omgeving openen. Geen gemengde batterijen gebruiken; verwijder oude batterijen om lekkage te voorkomen. Geen herlaadbare batterijen gebruiken. Repareer beschadigde apparatuur alvorens deze verder te gebruiken. Zorg dat tijdens het gebruik de lensring en de achtersluiting steeds goed vastgedraaid zijn. TR-40/TR-40+ Zone 1 LED: I M2/II 2 GD Ex ib I/IIC T4/T3 tD A21 IP67 T85°C (Omgevingstemperatuur -20°C tot +40°C) TR-45 Zone 0 LED: I M1/II 1 G Ex ia I/IIC T4/T3 IP67 (Omgevingstemperatuur -20°C tot +40°C) Aangemelde instantie: Baseefa Ltd., Rockhead Business Park, Staden Lane, Buxton, SK17 9RZ, UK. Aangemelde instantie nr.: 1180 EC-type Inspectiecertificaat: Baseefa07ATEX0091 Toegepaste harmonisatienormen: EN60079-0:2006(+EN60079-0:2004), EN60079-11:2007(+EN50020:2002), EN61241-0:2006, EN61241-1:2004 Stof- en waterdichtheidsgraad: IP67 volgens EN60529:1992 Dit product is voorzien van het CE-symbool om aan te geven dat aan alle relevante EC-richtlijnen wordt voldaan. Alex Jackson – Technisch Directeur Wolf Safety Lamp Company Ltd Gebruik uitsluitend originele Wolf-onderdelen De Wolf Safety Lamp Co. Ltd werkt voortdurend aan de verbetering van haar producten. Ontwerpwijzigingen kunnen zonder voorafgaande kennisgeving worden aangebracht. Ne pas ouvrir les lampes torches dans les zones Ex. Ne pas mélanger les piles ; retirer les piles afin d’éviter toute fuite. Ne pas utiliser de piles rechargeables. Tout équipement endommagé doit être réparé avant toute utilisation. Lors de l’utilisation, s’assurer que la bague du verre et le capuchon d’embout sont toujours vissé complètement. TR-40/TR-40+ Zone 1 LED: I M2/II 2 GD Ex ib I/IIC T4/T3 tD A21 IP67 T85°C (Température ambiante -20°C à +40°C) TR-45 Zone 0 LED: I M1/II 1 G Ex ia I/IIC T4/T3 IP67 (Température ambiante -20°C à +40°C) Organisme notifié : Baseefa Ltd., Rockhead Business Park, Staden Lane, Buxton, SK17 9RZ, UK. Organisme notifié nº 1180 Certificat de contrôle type CE: Baseefa07ATEX0091 Normes harmonisées appliquées: EN60079-0:2006(+EN60079-0:2004), EN60079-11:2007(+EN50020:2002), EN61241-0:2006, EN61241-1:2004 Niveau de protection (captage) : IP67 à EN60529:1992 Le produit porte la marque CE, prouvant qu’il est conforme à toutes les directives CE applicables. Alex Jackson – Directeur technique Wolf Safety Lamp Company Ltd Utiliser uniquement des pièces de rechange Wolf originales La société Wolf Safety Lamp Co. Ltd possède une politique d’amélioration constante de ses produits. Les détails de conception peuvent être modifiés sans préavis. Die Taschenlampe darf in explosionsgefährdeten Bereichen nicht geöffnet werden. Es dürfen keine unterschiedlichen Marken oder alte und neue Batterien miteinander vermischt werden. Alte, verbrauchte Batterien sind zu entfernen, um ein Auslaufen zu vermeiden. Wiederaufladbare Batterien dürfen nicht benutzt werden. Ein beschädigtes Gerät muss repariert werden, bevor es weiter benutzt wird. Während des Gebrauchs sicherstellen, dass sämtliche Verschlüsse fest zugedreht sind. TR-40/TR-40+ Zone 1 LED: TR-45 Zone 0 LED: I M2/II 2 GD Ex ib I/IIC T4/T3 tD A21 IP67 T85°C (Temperatur Umgebungsbereich -20°C bis +40°C) I M1/II 1 G Ex ia I/IIC T4/T3 IP67 (Temperatur Umgebungsbereich -20°C bis +40°C) Benannte Stelle: Baseefa Ltd., Rockhead Business Park, Staden Lane, Buxton, SK17 9RZ, UK. Benannte Stelle Nr. 1180 EG-Baumusterprüfbescheinigung Baseefa07ATEX0091 Geltende harmonisierte Normen: EN60079-0:2006(+EN60079-0:2004), EN60079-11:2007(+EN50020:2002), EN61241-0:2006, EN61241-1:2004 Schutzklasse: IP67 nach 529:1992 Das Produkt ist mit der CE-Marke versehen und erfüllt demzufolge alle relevanten EG-Richtlinien. Alex Jackson – Technical Director Wolf Safety Lamp Company Ltd Verwenden Sie nur Wolf-Originalersatzteile. Die Wolf Safety Lamp Co. Ltd. führt kontinuierlich Produktverbesserungen durch. Konstruktionsänderungen sind ohne vorherige Ankündigung möglich. Non aprire la torcia in aree pericolose. Non mischiare batterie, rimuovere le batterie usate per evitare perdita di elettrolito. Non servirsi di batterie ricaricabili. Dispositivi danneggiati devono essere riparati prima di un ulteriore utilizzo. Quando in uso, assicurarsi che l’anello della lente e il cappuccio siano sempre avvitati a fondo. TR-40/TR-40+ LED zona 1: I M2/II 2 GD Ex ib I/IIC T4/T3 tD A21 IP67 T85°C (Temperatura ambiente da -20°C a +40°C) TR-45 LED zona 0: I M1/II 1 G Ex ia I/IIC T4/T3 IP67 (Temperatura ambiente da -20°C a +40°C) Ente a cui è stata effettuata la comunicazione: Baseefa Ltd., Rockhead Business Park, Staden Lane, Buxton, SK17 9RZ, UK. Numero ente cui è stata effettuata la comunicazione: 1180 Certificato d’esame tipo CE: Baseefa07ATEX0091 Norme armonizzate applicate: EN60079-0:2006(+EN60079-0:2004), EN60079-11:2007(+EN50020:2002), EN61241-0:2006, EN61241-1:2004 Livello di protezione d’ingresso: IP67 a EN60529:1992 Il prodotto riporta il marchio CE che dimostra la sua conformità con tutte le direttive CE del caso. Alex Jackson – Direttore Tecnico Wolf Safety Lamp Company Ltd Servirsi unicamente di parti di ricambio originali Wolf. La Wolf Safety Lamp Co. Ltd osserva una politica volta al miglioramento continuo dei propri prodotti. È possibile che vengano apportate modifiche a dettagli del design senza preavviso. Não abra a lanterna numa Área Ex. Não misture pilhas; retire as pilhas usadas de modo a evitar derrames. Não utilize pilhas recarregáveis. Qualquer equipamento danificado deverá ser reparado antes de voltar a ser usado. Quando utilizar o equipamento, certifique-se de que o anel da lente e a tampa da extremidade se encontram bem enroscados. TR-40/TR-40+ Zona 1 LED: I M2/II 2 GD Ex ib I/IIC T4/T3 tD A21 IP67 T85°C (Temperatura ambiente -20°C a +40°C) TR-45 Zona 0 LED: I M1/II 1 G Ex ia I/IIC T4/T3 IP67 (Temperatura ambiente -20°C a +40°C) Entidade Notificada: Baseefa Ltd., Rockhead Business Park, Staden Lane, Buxton, SK17 9RZ, UK. Entidade Notificada No. 1180 Certificado de Exame CE de Tipo: Baseefa07ATEX0091 Normas harmonizadas aplicadas: EN60079-0:2006(+EN60079-0:2004), EN60079-11:2007(+EN50020:2002), EN61241-0:2006, EN61241-1:2004 Nível de protecção Ingress: IP67 a EN60529:1992 Este produto tem a marca CE mostrando estar em conformidade com todas as directivas relevantes. Alex Jackson –Director Técnico Wolf Safety Lamp Company Ltd Wolf ATEX LED-lygter er lygter med et primærbatteri, der forsyner stærkstrøms-LED-lyskilder, der er indstøbt i kraftig slagfast plastik. TR-40 og TR-40+ er godkendt som Gruppe I, M2-ustyr til anvendelse i miner og Gruppe II, kategori 2- udstyr til anvendelse i Zone 1 og 2 under tilstedeværelse af potentielt eksplosive gasser, dampe, tåger, og støv, hvor temperatur klassen for de specifikke batterier er gældende. TR-45 er godkendt som Gruppe I, M1-ustyr til anvendelse i miner og Gruppe II, kategori 1udstyr til anvendelse i Zone 0, 1 og 2 under tilstedeværelse af potentielt eksplosive gasser, dampe, tåger, og støv, hvor temperatur klassen for de specifikke batterier er gældende. Lygten må ikke åbnes på eksplosive områder. Wolf ATEX LED-lykter er støpt i plast som tåler kraftige slag. Lyktene er selvstendig drevne av to primærelementer og benytter høyeffekts LED lyskilde. TR-40 og TR-40+ er godkjent for gruppe I, M2-utstyr som brukes ved gruvedrift, og for gruppe II, kategori 2-utstyr som brukes i sone 1 og 2, der det er potensiell fare for eksplosive gasser, damp, tåke og støv hvor godkjenningskoden vedrørende temperaturklassen til bestemte elementer gjelder. TR-45 er godkjent for gruppe I, M1-utstyr som brukes ved gruvedrift, og for gruppe II, kategori 1-utstyr som brukes i sone 0, 1 og 2 der det er potensiell fare for eksplosive gasser, damp og tåke hvor godkjenningskoden vedrørende temperaturklassen til bestemte elementer gjelder. Batterierne må ikke blandes, fjern brugte batterier for at undgå lækage. Ikke åpne lykten i et eksplosjonsfarlig område. No abrir la linterna en áreas de deflagración. Benyt ikke genopladelige batterier. Ikke bland batterityper, og fjern brukte elementer for å unngå lekkasje. No mezcle las baterías, retire las baterías usadas para evitar fugas. Beskadiget udstyr skal repareres før det anvendes. Ikke bruk oppladbare batterier. No utilice baterías recargables. Under anvendelse skal det kontrolleres, at linsering og endehætte til hver en tid er fastspændt. Los equipos dañados deben repararse antes de volver a usarlos. Mientras se esté usando asegúrese de que en todo momento están colocados los anillos para las lentes y los tapones. TR-40/TR-40+ Zone 1 LED: I M2/II 2 GD Ex ib I/IIC T4/T3 tD A21 IP67 T85°C (Omgivelsestemperatur -20°C til +40°C) TR-40/TR-40+ Zona 1 LED: I M2/II 2 GD Ex ib I/IIC T4/T3 tD A21 IP67 T85°C (Temperatura ambiente -20°C a +40°C) TR-45 Zone 0 LED: I M1/II 1 G Ex ia I/IIC T4/T3 IP67 (Omgivelsestemperatur -20°C til +40°C) TR-45 Zona 0 LED: I M1/II 1 G Ex ia I/IIC T4/T3 IP67 (Temperatura ambiente -20°C a +40°C) Organismo notificador: Baseefa Ltd., Rockhead Business Park, Staden Lane, Buxton, SK17 9RZ, Reino Unido. Número del organismo notificador. 1180 Certificado de examen tipo CE: Baseefa07ATEX0091 Notificeret instans: Baseefa Ltd., Rockhead Business Park, Staden Lane, Buxton, SK17 9RZ, UK. Notificeret instans nr: 1180 EU-undersøgelsescertifikattype Baseefa07ATEX0091 Anvendte harmoniserede standarder: EN60079-0:2006(+EN60079-0:2004), EN60079-11:2007(+EN50020:2002), EN61241-0:2006, EN61241-1:2004 Skadet utstyr skal repareres før det brukes videre. TR-45 Sone 0 LED: I M1/II 1 G Ex ia I/IIC T4/T3 IP67 (Omgivelsestemperatur -20 °C til +40 °C) Instans som er underrettet: Baseefa Ltd., Rockhead Business Park, Staden Lane, Buxton, SK17 9RZ, Storbritannia. Underretningsnr: 1180 Utilice sólo piezas de repuesto Wolf genuinas. A Wolf Safety Lamp Co. Ltd tem uma política de melhoramento contínuo do produto. Poderão efectuar-se alterações ao design dos produtos sem aviso prévio. Wolf Safety Lamp Co. Ltd tiene como política la mejora continua de sus productos. Los cambios en los detalles de diseño pueden realizarse sin previo aviso. IP67 water and dust tight enclosure Zone 0 version available Group I Mining Approval EU-typegodkjenningssertifikat: Baseefa07ATEX0091 Inntregningsbeskyttelsesnivå: IP67 i hh til EN60529:1992 Use apenas peças de substituição da marca Wolf Over 7.5 hours high power output from 4 x AA primary cells Low battery indicator fitted on TR-40+ model Produktet er CE-mærket hvilket angive overholdelse af alle relevante EU-direktiver. Wolf Safety Lamp Co. Ltd. har som politik løbende produktforbedring. Ændringer i design detaljer kan udføres uden forudgående varsel. High output focussed spot beam I M2/II 2 GD Ex ib I/IIC T4/T3 tD A21 IP67 T85 °C (Omgivelsestemperatur -20 °C til +40 °C) Nivel de protección de penetración: IP67 según EN60529:1992 Alex Jackson – Technical Director Wolf Safety Lamp Company Ltd LED light source ‘fitted for life’ TR-40/TR-40+ Sone 1 LED: Beskyttelsesniveau imod indtrængning: IP67 til EN60529:1992 Benyt kun originale Wolf-reservedele ATEX Approved for explosive gas and dust atmospheres Compact and lightweight torch design Harmoniserte standarder som anvendes: EN60079-0:2006(+EN60079-0:2004), EN60079-11:2007(+EN50020:2002), EN61241-0:2006, EN61241-1:2004 Alex Jackson – Teknisk direktør Wolf Safety Lamp Company Ltd WOLF ATEX LED SAFETY TORCH Når lykten er i bruk skal man påse at linseringen og endedekslet alltid er strammet godt til. Normativas armonizadas aplicadas: EN60079-0:2006(+EN60079-0:2004), EN60079-11:2007(+EN50020:2002), EN61241-0:2006, EN61241-1:2004 El producto dispone de la marca CE para indicar que cumple con todas las directivas de la Comunidad Europea pertinentes. Wolf Safety Lamp Company Produktet er CE-merket, som viser samsvar med alle gjeldende EU-direktiver. Alex Jackson - teknisk direktør Safety Lamp Company Ltd Bruk bare originale Wolf-reservedeler The Wolf Safety Lamp Co. Ltd's bedriftspolitikk er å stadig forbedre sine produkter. Endringer i utformingen kan gjøres uten forvarsel. 1180 WOLF SAFETY LAMP COMPANY Saxon Road Works, Sheffield S8 0YA, England Tel: +44 114 255 1051 Fax: +44 114 255 7988 E-mail: [email protected] Website: www.wolf-safety.co.uk TP-560 Issue 3 MMD/???/12.09/?K Printed in England
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project