inStallation and oPEration Manual
EngliSH
Jandy Pro Series Stealth
™
Pumps
Models SHPF and SHPM
Warning
For Your SaFEtY - this product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist. the maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product.
Failure to follow warning notices and instructions may result in property damage, personal injury, or death. improper installation and/or operation will void the warranty.
improper installation and/or operation can create unwanted electrical hazard which can cause serious injury, property damage, or death. attEntion inStallEr - this manual contains important information about the installation, operation and safe use of this product. this information should be given to the owner/operator of this equipment.
Page 2
ENGLISH Jandy ® Pro Series Stealth ™ Pumps | Operation Manual
Jandy ® Pro Series Stealth ™ Pumps | Operation Manual ENGLISH
Page 3
table of Contents
Section 1. iMPortant SaFEtY inStruCtionS .................................................4
1.1 Safety Instructions ................................................ 4
1.2 Pool Pump Suction Entrapment
Prevention Guidelines .......................................... 6
Section 2. general description .........................7
2.1 Introduction ........................................................... 7
2.2 Description ........................................................... 7
Section 7. Product Specifications and technical data ................................19
7.1 Replacement Parts List ...................................... 19
7.2 Exploded View .................................................... 20
7.3 SHPF and SHPM Pump Curves ......................... 21
7.4 Physical and Operational Specifications ............ 22
7.5 SHP Replacement Motor Guide ......................... 23
Section 3. installation .........................................8
3.1 Plumbing .............................................................. 8
3.2 Electrical Installation ............................................. 9
3.3 Pressure Testing ................................................. 10
Section 4. operation .........................................12
4.1 Start-up ............................................................... 12
Section 5. Service and Maintenance ...............13
5.1 Routine Maintenance ......................................... 13
5.2 Winterizing the Pump ......................................... 13
Section 6. troubleshooting and repair ..........14
6.1 Troubleshooting .................................................. 14
6.2 Service Technician Maintenance ........................ 15
EquiPMEnt inForMation rECord
datE oF inStallation inStallEr inForMation initial PrESSurE gaugE rEading (WitH ClEan FiltEr)
PuMP ModEl HorSEPoWEr notES:
Page 4
ENGLISH Jandy ® Pro Series Stealth ™ Pumps | Operation Manual
Section 1. iMPortant SaFEtY inStruCtionS rEad and FolloW all inStruCtionS
1.1 Safety instructions
All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
Warning riSK oF SuCtion EntraPMEnt HaZard, WHiCH, iF not aVoidEd, Can rESult in SEriouS inJurY
or dEatH. Do not block pump suction as this can cause severe injury or death. Do not use this pump for wading pools, shallow pools or spas containing bottom drains, unless the pump is connected to at least two functioning suction outlets. Suction outlet (drain) covers must be certified to the latest published version of ANSI/
ASME A112.19.8.
Warning
To reduce the risk of injury, do not permit children to use this product.
Warning
To reduce the risk of property damage or injury, do not attempt to change the backwash (multiport, slide, or full flow) valve position with the pump running.
Warning
Zodiac ® pumps are powered by a high voltage electric motor and must be installed by a licensed or certified electrician or a qualified swimming pool service technician.
Warning
riSK oF ElECtriC SHoCK, FirE, PErSonal inJurY, or dEatH. Connect only to a branch circuit that is protected by a ground-fault circuit-interrupter (GFCI). Contact a qualified electrician if you cannot verify that the circuit is protected by a GFCI. Make sure such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the pump without the test button being pushed, a ground current is flowing, indicating the possibility of electrical shock. Do not use the pump. Disconnect the pump and have the problem corrected by a qualified service representative before using.
Due to the potential risk of fire, electric shock, or injuries to persons, Zodiac Pumps must be installed in accordance with the National Electric Code (NEC), all local electrical and safety codes, and the Occupational
Safety and Health Act (OSHA). Copies of the NEC may be ordered from the National Fire Protection Association online at www.nfpa.org or call 617-770-3000, or contact your local government inspection agency.
Warning
Incorrectly installed equipment may fail, causing severe injury or property damage.
Jandy ® Pro Series Stealth ™ Pumps | Operation Manual ENGLISH
Page 5
Warning
• Do not connect the system to an unregulated city water system or other external source of pressurized water producing pressures greater than 35 PSI.
• Trapped air in system can cause the filter lid to be blown off, which can result in death, serious personal injury, or property damage. Be sure all air is out of the system before operating.
Warning
To minimize the risk of severe injury or death the filter and/or pump should not be subjected to the piping system pressurization test.
Local codes may require the pool piping system to be subjected to a pressure test. These requirements are generally not intended to apply to the pool equipment such as filters or pumps.
Zodiac ® pool equipment is pressure tested at the factory.
However, if the WARNING cannot be followed and pressure testing of the piping system must include the filter and/or pump, BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS:
• Check all clamps, bolts, lids, lock rings and system accessories to ensure they are properly installed and secured before testing.
• RELEASE ALL AIR in the system before testing.
• Water pressure for test must NOT EXCEED 35 PSI.
• Water temperature for test must NOT EXCEED 100°F (38°C).
• Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.
notice: These parameters apply to Zodiac equipment only. For non-Zodiac equipment, consult equipment manufacturer.
Warning
Chemical spills and fumes can weaken pool/spa equipment. Corrosion can cause filters and other equipment to fail, resulting in severe injury or property damage. Do not store pool chemicals near your equipment.
Caution
do not start pump dry! Running the pump dry for any length of time will cause severe damage and will void the warranty.
Caution
This pump is for use with permanently installed pools and may also be used with hot tubs and spas if so marked.
Do not use with storable pools. A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it may be readily disassembled for storage and reassembled to its original integrity.
Caution
Do not install within an outdoor enclosure or beneath the skirt of a hot tub or portable spa. The pump requires adequate ventilation to maintain air temperature at less than the maximum ambient temperature rating listed on the motor rating plate.
Page 6
ENGLISH Jandy ® Pro Series Stealth ™ Pumps | Operation Manual
1.2 Pool Pump Suction Entrapment Prevention guidelines
Caution
The 3-phase SHPF series pumps utilize non-thermally protected motor assemblies. NRTL Listed Motor Controller with internal motor running overload protection or external motor running overload are required during the final installation of the pump assembly. Overloads shall be set at a maximum of 125% of the full-load current rating of the pump motor assembly.
Warning
SuCtion HaZard. Can cause serious injury or death. do not use this pump for wading pools, shallow pools or spas containing bottom drains, unless the pump is connected to at least two (2) functioning suction outlets.
Warning
Pump suction is hazardous and can trap and drown or disembowel bathers. do not use or operate
swimming pools, spa, or hot tubs if a suction outlet cover is missing, broken, or loose. The following guidelines provide information for pump installation that minimizes the risk of injury to users of pools, spas, and hot tubs:
Entrapment Protection - The pump suction system must provide protection against the hazards of suction entrapment.
Suction outlet Covers - All suction outlets must have correctly installed, screw-fastened covers in place. All suction outlet (drain) covers must be maintained. Drain covers must be listed/certified to the latest version of
ANSI/ASME A112.19.8. They must be replaced if cracked, broken, or missing.
number of Suction outlets Per Pump - Provide at least two (2) hydraulically-balanced main drains, with covers, as suction outlets for each circulating pump suction line. The centers of the main drains (suction outlets) on any one (1) suction line must be at least three (3) feet apart, center to center. See Figure 1 on page 7.
The system must be built to include at least two (2) suction outlets (drains) connected to the pump whenever the pump is running. However, if two (2) main drains run into a single suction line, the single suction line may be equipped with a valve that will shut off both main drains from the pump. The system shall be constructed such that it shall not allow for separate or independent shutoff or isolation of each drain. See Figure 1 on page 7.
More than one (1) pump can be connected to a single suction line as long as the requirements above are met.
Water Velocity - The maximum water velocity through the suction fitting or cover for any suction outlet must be
1.5 feet per second unless the outlet complies with the latest version of ANSI/ASME A112.19.8, the standard for
Suction Fittings For Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs. In any case, do not exceed the suction fitting’s maximum designed flow rate.
If 100% of the pump’s flow comes from the main drain system, the maximum water velocity in the pump suction hydraulic system must be 6 feet per second or less, even if one (1) main drain (suction outlet) is completely blocked. The flow through the remaining main drain(s) must comply with the latest version of ANSI/ASME
A112.19.8, the standard for Suction Fittings For Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs.
testing and Certification - Suction outlet covers must have been tested by a nationally recognized testing laboratory and found to comply with the latest version of ANSI/ASME A112.19.8, the standard for Suction Fittings
For Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs.
Fittings - Fittings restrict flow; for best efficiency use fewest possible fittings (but at least two (2) suction outlets).
Avoid fittings which could cause an air trap.
Pool cleaner suction fittings must conform to applicable International Association of Plumbing and Mechanical
Officials (IAPMO) standards.
SaVE tHESE inStruCtionS
Jandy ® Pro Series Stealth ™ Pumps | Operation Manual ENGLISH
At least three (3) feet
Listed/certified to latest published version of
ANSI/ASME
A112.19.8 - 2007
Anti-entrapment
Cover/Grate or Suction
Fitting, screw-fastened
to Main Drain Sump
Suction Outlet
(Main Drain)
No valves between
Tee and Main Drains
Valves OK between pump and Tee
Listed/certified to latest published version of
ANSI/ASME
A112.19.8 - 2007
Anti-entrapment
Cover/Grate or Suction
Fitting, screw-fastened
to Main Drain Sump
Suction Outlet
(Main Drain)
Pump
Page 7
Figure 1. number of Suction outlets Per Pump
Section 2. general description
2.1 introduction
This manual contains information for the proper installation, operation and maintenance of Jandy Pro
Series Stealth (SHP) Pumps. Procedures in this manual must be followed exactly. To obtain additional copies of this manual contact Zodiac Pool Systems, Inc. ("Zodiac") at 800.822.7933. For address information, see the back cover of this manual.
2.2 description
SHP Pumps are designed to meet the needs of today’s more hydraulically demanding pool equipment. The pump housing, backplate, diffuser, hair and lint pot
(pump debris filter basket), and impeller are all made from high quality thermoplastic materials. These materials were chosen for their strength and corrosion resistance.
The pump is driven by an electric motor directly attached to the pump impeller. As the electric motor turns, it causes the impeller to turn, which forces water to flow through the pump. The water flows through the pump inlet and then into the filter basket. The basket assembly pre-strains and traps large particles. The water then enters the center of the pump housing, flows through the impeller into the diffuser, and then flows out the pump discharge port.
Page 8
ENGLISH
Section 3. installation
3.1 Plumbing
3.1.1 Preparation
1. Upon receipt of the pump, check the carton for damage. Open the carton and check the pump for concealed damage, such as cracks, dents or a bent base. If damage is found, contact the shipper or distributor where you purchased the pump.
2. Inspect the contents of the carton and verify that all the parts are included. See Section 7.1,
Replacement Parts List.
Jandy ® Pro Series Stealth ™ Pumps | Operation Manual
5. The pump foundation must have adequate drainage to prevent the motor from getting wet.
The pump needs to be protected from the rain and sun.
6. Proper ventilation is required for the pump to operate normally. All motors generate heat that must be removed by providing proper ventilation.
7. Provide access for future service by leaving a clear area around the pump. Allow plenty of space above the pump to remove the lid and basket for cleaning.
8. If the equipment is under cover, provide adequate lighting.
3.1.2 Pump location
1. Zodiac Pool Systems, Inc. recommends installing the pump within one (1) foot above the water level. The pump should not be elevated more than a few feet above the water level of the pool.
A check valve is recommended on the suction line to the pump.
notE Better self-priming will be achieved if the pump is installed as close as possible to the water level of the pool.
2. If the pump is located below water level, isolation valves must be installed on both the suction and return lines to prevent back flow of pool water during any routine or required servicing.
Warning
Some Safety Vacuum Release System (SVRS) devices are not compatible with installation of check valves. If the pool has an SVRS device, be sure to confirm that it will continue to safely operate when any check valves are installed.
3. The pump and other circulation equipment must be located more than five (5) feet from the water.
Choose a location that will minimize turns in the piping. notE In Canada, the pump must be located a minimum of three (3) meters [approximately ten (10) feet] from the water (CSA C22.1).
4. The pump must be placed on a solid foundation that will not vibrate. To further reduce the possibility of vibration noise, bolt the pump to the foundation.
notE Zodiac Pool Systems, Inc. recommends bolting the pump directly to the foundation.
3.1.3 Pipe Sizing notE All HP ratings given in this section apply to full-rated pumps. For help with max-rated pumps, contact
Zodiac Technical Support at 800.822.7933.
3.1.3.1 Suction Pipe
When the pump is located up to 50 feet from the pool, the recommended minimum pipe size for the suction side of the pump is:
• 2" for .75 to 1.5 HP*
• 2½" for 2.0 HP*
• 3" for 3.0 HP*
• 4" for 5.0 HP*
* HP refers to full-rated pumps
3.1.3.2 discharge Pipe
When the pump is located up to 50 feet from the pool, the recommended minimum pipe size for the discharge side of the pump is:
• 2" for .75 to 1.5 HP*
• 2½" for 2.0 HP*
• 3" for 3.0 HP*
• 4" for 5.0 HP*
* HP refers to full-rated pumps
notE All pipe sizes are able to withstand the pressures the pump will deliver, but not necessarily the flow. If the pipe is too small for the pump, or it is elevated above water, the maximum gallons per minute (GPM) may not be delivered. If this happens, the pump will develop an air pocket (cavitation) that will make noise and the pump life will be shortened.
3.1.3.3
1. If the pump is located below water level, isolation valves must be installed on both sides
2. To help prevent difficulty in priming, install the suction pipe without high points (above inlet of pump - inverted “U”s in plumbing), which can trap air. For installations of equipment up to 100 feet from the water, refer to the pipe sizing chart,
Table 1. For installations of equipment more than
100 feet from the water, the recommended pipe must be increased to the next size.
table 1. Pipe Sizing Chart for Schedule 40 PVC
Pipe
Size
1½"
2"
Maximum Flow
Suction
(8 feet per second)
Maximum Flow discharge
(10 feet per second)
50 GPM (189 LPM) 65 GPM (246 LPM)
85 GPM (322 LPM) 105 GPM (397 LPM)
2½" 120 GPM (454 LPM) 149 GPM (564 LPM)
3" 184 GPM (697 LPM) 230 GPM (871 LPM)
4" 317 GPM (1203 LPM) 397 GPM (1502 LPM)
3.
Jandy ® Pro Series Stealth ™ Pumps | Operation Manual installation recommendations of the pump to prevent back flow of pool water during any routine or required servicing.
SHP Pumps come equipped with unions on both the suction and discharge ports. This feature simplifies installation and service, and eliminates the possibility of leaks at threaded adapters.
4. The SHP Pump must be connected to at least two
(2) hydraulically balanced main drains (suction outlets) for each pool pump suction line. Each drain must be provided with covers that are listed or certified to the latest version of ANSI/ASME
A112.19.8. The suction outlets of the main drains must be at least three (3) feet apart or at different planes. The suction outlets can be a drain and skimmer, two (2) drains, two (2) skimmers, or a skimmer with an equalizer line installed. Check the local codes for proper installation requirements.
notE To prevent entrapment, the system must be built so that it cannot operate with the pump drawing water from only one (1) main drain. At least two (2) main drains must be connected to the pump when it is in operation. However, if two (2) main drains run into a single suction line, the single suction line may be equipped with a valve which will shut off both main drains from the pump.
5. The piping must be well supported and not forced together where constant stress will be experienced.
6. Always use properly sized valves. Jandy Pro
Series Diverter Valves and Ball Valves typically have the best flow capabilities.
7. Use the fewest fittings possible. Every additional fitting has the effect of moving the equipment farther away from the water. notE If more than 10 suction fittings are needed, the pipe size must be increased.
8. If this is a new installation, pressure test according to local codes. See Section 3.3,
Pressure Testing.
3.2 Electrical installation
3.2.1 Voltage Checks
The correct voltage, as specified on the pump data plate, is necessary for proper performance and long motor life.
Incorrect voltage will decrease the pump’s ability to perform and could cause overheating, reduce the motor life, and result in higher electric bills.
It is the responsibility of the electrical installer to provide data plate operating voltage to the pump by ensuring proper circuit sizes and wire sizes for this specific application.
ENGLISH
The National Electrical Code (NEC, NFPA-70) requires all pool pump circuits be protected with a Ground Fault
Interrupter (GFCI). Therefore, it is also the responsibility of the electrical installer to ensure that the pump circuit is in compliance with this and all other applicable requirements of the National Electrical Code (NEC) and any other applicable installation codes.
Caution
Page 9
Failure to provide data plate voltage (within 10%) during operation will cause the motor to overheat and void the warranty.
3.2.2 Bonding and grounding
1. The motor frame must be grounded to a reliable grounding point using a solid copper conductor,
No. 8 AWG or larger. In Canada, No. 6 AWG or larger must be used. If the pump is installed within five (5) feet of the inside walls of the swimming pool, spa, or hot tub, the motor frame must be bonded to all metal parts of the swimming pool, spa, or hot tub structure and to all electrical equipment, metal conduit, and metal piping within five (5) feet of the inside walls of the swimming pool, spa, or hot tub.
2. Bond the motor using the provided external lug.
Page 10
ENGLISH
Warning
To avoid the risk of property damage, severe personal injury, and/or death, always disconnect the power source before working on a motor or its connected load.
Warning
To avoid the risk of property damage, severe personal injury, and/or death, make sure that the control switch or time clock is installed in an accessible location so that in the event of an equipment failure or a loose plumbing fitting the equipment can be turned off. This location must not be in the same area as the pool pump, filter, and other equipment.
Warning
The pump must be permanently connected to a dedicated electrical circuit. No other equipment, lights, appliances or outlets may be connected to the pump circuit, with the exception of devices that may be required to operate simultaneously with the pump, such as a chlorinating device or heater.
Jandy ® Pro Series Stealth ™ Pumps | Operation Manual
2. Wire size must be adequate to minimize voltage drop during the start-up and operation of the pump. See Table 2 for recommended wire sizes.
3. Insulate all connections carefully to prevent grounding or short-circuits. Sharp edges on terminals require extra protection. To prevent wire nuts from loosening, tape them using a suitable, listed (UL, ETL, CSA) electrical insulating tape.
For safety, and to prevent entry of contaminants, reinstall all conduit and terminal box covers. Do not force connections into the conduit box.
4. To configure the internal wiring of the pump motor for the correct voltage, refer to the diagram on the motor data plate.
3.3 Pressure testing
All model SHP pumps come with an additional disposable o-ring for pressure testing. This is the blue pressure test o-ring. See Figures 2 and 3.
3.2.3 Electrical Wiring
1. The pump motor must be securely and adequately grounded using the green screw provided. Ground before attempting to connect to an electrical power supply. Do not ground to a gas supply line.
Caution
Do not open the pump lid before pressure testing, because the blue pressure test o-ring may fall out. If this happens, you will need to replace it.
If you have not opened the pump lid, skip to Section
3.3.2, Conduct Pressure Test.
table 2. recommended Minimum Wire Size
rECoMMEndEd MiniMuM WirE SiZE For SHP PuMPS*
distance from Sub-Panel 0-50 Feet 50-100 Feet 100-150 Feet
Pump Model
Branch Fuse aMPs
Class: CC, g, H, J, K, rK, or t
Voltage Voltage Voltage
150-200 Feet
Voltage
SHPF .50HP/SHPM .75HP
SHPF .75HP/SHPM 1.0HP
SHPF 1.0HP/SHPM 1.5HP
SHPF 1.0-3PH
SHPF 1.5HP/SHPM 2.0HP
SHPF 1.5-3PH
SHPF 2.0HP/SHPM 2.5HP
SHPF 2.0-3PH
SHPF 3.0HP
SHPF 3.0-3PH
230VaC 115VaC
15A
15A
15A
15A
15A
15A
15A
15A
20A
15A
15A
15A
20A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
208-230 VaC 115 VaC 208-230 VaC 115 VaC 208-230 VaC 115 VaC 208-230 VaC 115 VaC
14
14
12
12
12
12
8
8
10
10
6
6
8
8
6
6
12
14
12
12
10
N/A
N/A
N/A
10
12
10
10
8
N/A
N/A
N/A
8
10
8
8
6
N/A
N/A
N/A
6
8
6
6
4
N/A
N/A
N/A
12
12
10
12
N/A
N/A
N/A
N/A
8
10
8
8
N/A
N/A
N/A
N/A
6
8
6
6
N/A
N/A
N/A
N/A
6
6
4
6
N/A
N/A
N/A
N/A
SHPF 5.0
SHPF 1.0HP-2-SPD (1)
SHPF 1.5HP-2-SPD (1)
SHPF 2.0HP-2-SPD (1)
25A
15A
15A
15A
N/A
N/A
N/A
N/A
10
12
12
12
N/A
N/A
N/A
N/A
8
10
10
8
N/A
N/A
N/A
N/A
6
8
8
6
N/A
N/A
N/A
N/A
6
6
6
6
N/A
N/A
N/A
N/A
SHPM 1.5HP-2-SPD (1)
SHPM 2.0HP-2-SPD (1)
SHPM 2.5HP-2-SPD (1)
15A
15A
15A
N/A
N/A
N/A
12
12
12
N/A
N/A
N/A
10
10
8
N/A
N/A
N/A
8
8
6
N/A
N/A
N/A
6
6
6
N/A
N/A
N/A
*Assumes three (3) copper conductors in a buried conduit and 3% maximum voltage loss in branch circuit. All National Electrical Code (NEC) and local codes must be followed. Table shows minimum wire size and branch fuse recommendations for a typical installation per NEC.
(1) Two-speed pumps are not rated for use with 208 VAC.
Lid with
Locking
Ring and
Seal
Blue
Pressure
Test
O-ring
Pump
Debris
Trap
Basket
(Inside
Pump)
Figure 2. Exploded View of Pump
Lid with
Locking
Ring
Jandy ® Pro Series Stealth ™ Pumps | Operation Manual ENGLISH
Page 11
3.3.1.1 remove Pump lid
1. Make sure that the pump is turned off.
2. Make sure that the switch to the circuit breaker that powers the pump motor is turned off.
Warning
Turn off the pump and the main breaker in the pump electrical circuit before starting the procedure. Failure to comply may cause a shock hazard, resulting in severe personal injury or death.
Warning
Due to the potential risk of fire, electric shock, or injuries to persons, Jandy Pro Series Pumps must be installed in accordance with the National Electrical
Code ® (NEC), in the USA, or the Canadian Electrical
Code (CEC) in Canada. All applicable local codes must also be followed.
The NEC may be obtained by contacting the
National Fire Protection Association (NFPA) at
1-800-344-3555 or 1-617-770-3000.
Seal
3. Make sure all necessary isolation valves are closed to prevent pool water from reaching the pump.
4. Following the markings on the locking ring, turn the ring counter-clockwise until the ‘START’ markings align with the ports.
5. Carefully remove the lid with locking ring.
Blue Pressure Test O-ring
Figure 3. Blue Pressure test o-ring in lid assembly
3.3.1 replace Blue Pressure test o-ring if necessary
If you open the pump lid before conducting the pressure test, the blue o-ring will probably fall out. If this happens, you will need to install it on the lid again before conducting pressure testing.
3.3.1.2 replace Blue o-ring
1. Turn the lid with locking ring upside down and place it on a stable surface.
2. Place the blue o-ring on the step located ¼" from the bottom of the lid. See Figure 4.
3. Make sure that the o-ring is properly seated. It helps to “place” the o-ring on the step rather than to “roll” it on. That prevents it from rolling off.
There is a risk of damage to the blue o-ring during reinstallation. If you damage it when trying to re-install it, you will need to order a new blue pressure test o-ring
(R0479000) before you begin conducting the pressure test.
These instructions describe the proper procedures for replacing, using, and disposing of the blue o-ring.
These instructions must be followed exactly. Read through the instructions completely before starting the procedure.
notE The blue o-ring sits approximately ¼" away from the seal. See Figure 4.
4. Carefully install the lid, making sure that the blue pressure test o-ring sits in the housing without
“binding” or “rolling” off.
5. Following the markings on the locking ring, align ‘START’ markings with the ports and turn clockwise until ‘LOCKED’ markings align with the ports. Do not tighten past the ‘LOCKED’ marking.
Page 12
ENGLISH
Upside Down View of
Bottom of Lid
Groove where
Seal is Seated
Step where
O-ring is Seated
Figure 4. Placement of Blue Pressure test o-ring
3.3.2 Conduct Pressure test
Warning
When pressure testing a system with water, air is often trapped in the system during the filling process.
This air will compress when the system is pressurized. Should the system fail, this trapped air can propel debris at a high speed and cause injury. Every effort to remove trapped air must be taken, including opening the bleed valve on the filter and loosening the pump basket lid while filling the pump.
Warning
Trapped air in system can cause filter lid to be blown off, which can result in death, serious personal injury, or property damage. Be sure all air is properly out of system before operating. DO NOT USE COM-
PRESSED AIR TO PRESSURE TEST OR CHECK
FOR LEAKS.
Warning
When pressure testing the system with water, it is very important to make sure that the pump basket lid is completely secure.
Warning
Do not pressure test above 35 PSI. Pressure testing must be done by a trained pool professional.
Circulation equipment that is not tested properly can fail, which could result in severe injury or property damage.
1. Fill the system with water, using care to eliminate trapped air.
2. Pressurize the system with water to no more than 35 PSI.
3. Close the valve to trap pressurized water in the system.
Jandy ® Pro Series Stealth ™ Pumps | Operation Manual
4. Observe the system for leaks and/or pressure decay.
5. If there are lid leaks, repeat steps 1-3. For technical support, call 800.822.7933.
6. Discard the blue pressure test o-ring after successfully completing the test.
Section 4. operation
4.1 Start-up
Caution
Never run the pump without water. Running the pump
“dry” for any length of time can cause severe damage to both the pump and motor and will void the warranty.
If this is a new pool installation, make sure all piping is clear of construction debris and has been properly pressure tested. The filter should be checked for proper installation, verifying all connections and clamps are secure according to the manufacturer's recommendations.
Warning
To avoid risk of damage or injury, verify that all power is turned off before starting this procedure.
1. Release all pressure from the system and open the filter pressure release valve.
2. If the pump is located below the water level of the pool, opening the filter pressure release valve will prime the pump with water.
3. If the pump is located above the water level of the pool, remove the lid and fill the basket with water before starting the pump.
4. Prior to replacing the lid, check for debris around the lid o-ring seat. Debris around the lid o-ring seat will cause air to leak into the system, and make it difficult to prime the pump.
5. Hand-tighten the lid to make an air tight seal. Do not use any tools to tighten the lid, hand-tighten only. Make sure all valves are open and the unions are tight.
6. Turn on the power to the pump. Then turn on the pump.
7. Once all the air has left the filter, close the pressure release valve.
8. The pump should prime. The time it takes to prime will depend on the elevation and length of pipe used on the suction supply pipe. See Section
3.1.3.3 for proper elevation and pipe size.
9.
Jandy ® Pro Series Stealth ™ Pumps | Operation Manual
If the pump does not prime and all the instructions to this point have been followed, check for a suction leak and then repeat Steps 2 through 7.
ENGLISH
Page 13
10. Turn on the power to the pump. Once all the air has been evacuated from the filter, close the pressure release valve.
Section 5. Service and
Maintenance
5.1 routine Maintenance
Inspect the pump basket for debris by looking through the clear pump lid. Remove any debris, because as debris accumulates, it will begin to block the flow of water through the pump. Keep the basket clean to improve the performance of the pump.
5.2 Winterizing the Pump
Caution
The pump must be protected when freezing temperatures are expected. Allowing the pump to freeze will cause severe damage and void the warranty.
Caution
Do not use antifreeze solutions in the pool, spa,
or hot tub systems! Antifreeze is highly toxic and may damage the circulation system. The only exception to this is Propylene Glycol. For more information see your local pool/spa supply store or contact a qualified swimming pool service company.
1. Turn off the power to the pump. If the pump is located below the water level, close the isolation valves on the suction and discharge sides of the pump to prevent a backflow of water.
2. Turn the lid's locking ring counter-clockwise until 'START' aligns with the ports. (You may use a tool for leverage to open the lid, but never
to tighten the lid when closing it.) Carefully remove the lid.
Caution
A misaligned basket will cause the lid to be improperly seated, allowing an air leak which could result in pump damage.
1. Drain all water from the pump, system equipment, and piping.
2. Remove the two drain plugs. Store the drain plugs in a safe location and reinstall them when the cold weather season is over. Do not lose the
o-rings. (Drain Plug with O-ring Set, R0446000)
3. Keep the motor covered and dry.
3. Lift the basket out of the pump.
4. Dispose of the debris and thoroughly clean the basket, making sure all the holes are open. Using a garden hose, spray the basket from the outside to help clear the holes. Use your hands to remove any remaining debris.
5. Replace the basket in the pump by aligning the opening with the suction pipe. If aligned properly, the basket will drop easily into place.
Do not force into place.
6. Prior to replacing the lid, check for debris around the lid o-ring seat, as this will cause air to leak into the system. Clean the lid o-ring and place it on the lid.
7. Hand-tighten the lid to make an air tight seal. Do not use any tools to tighten the lid: hand-tighten only.
8. Verify that all valves have been returned to the proper position for normal operation.
9. Open the pressure release valve on the filter, and make sure it is clean and ready for operation. notE Covering the pump with plastic will create condensation, and this moisture will damage the pump. The best way to protect your pump is to have a qualified service technician or electrician properly disconnect the electrical wiring at the switch or junction box. Once the power is removed, the two unions can be loosened and the pump stored indoors. For safety, and to prevent entry of contaminants, reinstall all conduit and terminal box covers.
4. When the system is reopened for operation, make sure all piping, valves, wiring, and equipment are in accordance with the manufacturer's recommendations. Pay close attention to the filter and electrical connections.
5. The pump must be primed prior to starting; refer to Section 4.1, Start-up.
Page 14
ENGLISH Jandy ® Pro Series Stealth ™ Pumps | Operation Manual
Section 6. troubleshooting and repair
Zodiac Pool Systems, Inc. strongly recommends that you call a qualified service technician to perform any repairs on the filter/pump system. To locate an independent service company, check your local yellow pages or visit www.jandy.
com and click on "Product Support."
6.1 troubleshooting
Symptom Possible Problem/Solution
The cleaning/circulating system is not operating correctly.
Bubbles present in the pump basket.
Air leaks are still present.
There is no air in the system, but the pressure is still low.
There is no debris blocking the impeller and the pressure is still low.
The pump is leaking water between the motor and pump body.
The pump gets hot and shuts off periodically.
Verify that skimmer baskets, pump basket and other screens are clean. Clean as necessary.
Check filter and clean as necessary.
Check valve positions. Adjust as necessary.
notE Multiple pieces of equipment operating at one time (for example, waterfalls, spa jets, and surface returns) may prevent the cleaning system from working properly.
Check the cleaning system manually to ensure that the system is adjusted according to the manufacturer's recommendations.
Air in system. Check the pool or spa water level to ensure it is at the proper level and that air is not being drawn into the suction piping. If the water is at normal level, turn off the pump. Remove the lid and check for debris around the lid o-ring seat or improper installation of the lid seal, as this either of these conditions will cause air to leak into the system. Clean the lid o-ring and place on the lid. Hand-tighten the lid to make an air tight seal. Do not use any tools to tighten the lid. Turn the pump back on.
Check the suction side piping union. While the pump is running, try to tighten the union. If this does not stop the air leak, turn off the pump. Loosen both unions and slide the pump out of the way. Remove, clean and re-install both union o-rings.
Reposition the pump next to the piping and secure the union nuts to the pump. With clean union o-rings, hand-tightening of the unions should create a seal. If the unions still do not seal, gently tighten with a large pair of tongue-and-groove pliers.
Do not over-tighten.
It is possible that debris is caught in the pump impeller. The pump impeller moves the water, and the vanes in the impeller can become blocked with debris. See
Section 6.2, Service Technician Maintenance, 6.2.1, Blocked Impeller, for more information.
The pump impeller and diffuser are showing signs of normal wear. Have a qualified service technician check the impeller and diffuser and replace as necessary.
If the pump is part of a relatively new installation, it could be an electrical problem.
Contact a qualified service technician. Have the technician check for loose electrical connections and check the voltage at the pump motor while it is in operation. The voltage must be within 10% of the motor's data plate rating. If the voltage is not within 10%, contact a qualified electrician and/or the local power service provider.
Pump seal is leaking air. Have a qualified service technician replace the seal.
This is caused by a damaged or failed mechanical seal. Replace the seal. See
Section 6.2, Service Technician Maintenance, 6.2.4, Mechanical Seal Replacement.
Ensure that there is adequate room around the motor to circulate air and keep the motor cool. Have a qualified electrician check for loose connections and check the voltage at the pump motor while it is in operation. The voltage must be within 10% of the motor's data plate rating. If the voltage is not within 10%, contact a qualified electrician and/or the local power service provider.
Jandy ® Pro Series Stealth ™ Pumps | Operation Manual
6.2 Service technician Maintenance
Warning
This pump must be serviced by a professional service technician, qualified in pool/spa installation. The following procedures must be followed exactly. Improper installation and/or operation can create dangerous electrical hazards, which can cause high voltages to run through the electrical system, possibly causing property damage, serious injury, or death. Improper installation and/or operation will void the warranty.
ENGLISH
Page 15
2. Turn off any valves to prevent pool water from
Reaching the pump. Drain the water from the pump by loosening the unions or removing the drain plugs.
3. Using a 9/16" wrench, loosen the bolts connecting the pump body to the motor backplate. See Figure 5.
Bolts (8)
6.2.1 Blocked impeller
Warning
While servicing the pump, switch off the circuit breakers at the power source. Severe personal injury or death may occur if the pump starts while your hand is inside the pump.
Pump
Body
Motor Backplate
1. Turn off the pump. Switch off the circuit breaker to the pump motor.
2. Remove the lid and basket.
3. Look inside the pump for any debris. Remove any debris found inside.
4. Replace the basket and lid.
5. Switch on the circuit breaker to the pump motor.
6. Turn on the pump, and see if the problem is solved.
7. If the impeller is still blocked with debris and it is not possible to remove the debris using steps 2 through 4, the pump will need to be disassembled in order to access the inlet and outlet of the impeller.
Motor Shaft Cover
Figure 5. remove the Pump Housing
4. Pull the motor and backplate out of the pump body. Remove the pump body o-ring. The impeller is connected to the motor shaft.
5. Using a No. 1 Phillips screwdriver, remove the two (2) screws holding the diffuser. (The diffuser is the cover over the impeller.) Then remove the diffuser, see Figure 6. The SHPF 5.0 uses a different diffuser than other models. See Figure 8.
notE At this point you have access to the inlet and outlet of the impeller to remove any debris.
Backplate
6.2.2 impeller removal
Warning
While servicing the pump, switch off the circuit breakers at the power source. Severe personal injury or death may occur if the pump starts while your hand is inside the pump.
1. Turn off the pump. Switch off the circuit breaker to the pump motor. If you are not replacing the motor, do not disconnect the electrical wiring.
Motor diffuser
Screws with Washers
(2) notE If you are replacing the motor, Zodiac Pool Systems,
Inc., strongly recommends that a qualified service technician or electrician properly disconnect the electrical wiring at the pump motor.
Motor diffuser o-ring
Figure 6. remove the diffuser
Page 16
ENGLISH Jandy ® Pro Series Stealth ™ Pumps | Operation Manual
Pump Body diffuser o-ring diffuser diffuser o-ring diffuser Screws with Washers (2)
Self Sealing left
Handed Screw
Backplate o-ring diffuser impeller o-ring location for SHP only o-ring location for PHP/MHP only
Figure 7. location of the diffuser o-ring diffuser
Pump Body diffuser o-ring
Mechanical
Seal
Backplate
Figure 10. diffuser and impeller Exploded View
6. Remove the motor shaft cover on the back of the motor by twisting the hex-head screw with a 90° crescent wrench, see Figure 5. The motor shaft will be exposed.
7. Hold the exposed motor shaft with a ½" wrench while removing the impeller center screw using a
No. 3 Phillips screwdriver. See Figure 9. notE The impeller center screw is a left-hand threaded screw. Therefore, turn the screw clockwise to loosen.
8. Hold the motor shaft with a ½" wrench while unscrewing the impeller from the motor shaft with your hand. notE The impeller is a right-handed thread, therefore turn the impeller counter-clockwise to unscrew.
9. Inspect the impeller and diffuser for signs of rubbing and/or damage.
Figure 8. location of the diffuser o-ring on a SHPF
5.0 HP only
Self Sealing left
Handed Screw
6.2.3 impeller replacement
1. Press the new carbon face seal half, see Figure
11 on the motor shaft using a twisting motion.
Make sure the carbon surface is facing toward the ceramic ring in the backplate.
Caution
VErY iMPortant! Grasp the lower portion of the seal (opposite the carbon face) when installing the seal, or it will be damaged.
Backplate impeller
Mechanical Seal
Figure 9. remove the impeller notE To assist assembly, only use water and soap solution as a lubricant. Any other lubricant will destroy the seal after a short period of time. notE Exercise great care to keep the seal and mating parts clean.
2.
Jandy ® Pro Series Stealth ™ Pumps | Operation Manual
While holding the motor shaft with a ½" wrench, thread the impeller onto the motor shaft. Handtighten the impeller until it is secure. Install the impeller center screw into the center of the impeller and tighten, using a No. 3 Phillips screwdriver. Do not overtighten. notE The impeller center screw is a left-hand threaded screw. Therefore, turn the screw counter-clockwise to tighten.
3. Replace the motor shaft cover by inserting the cover tabs into the slots and rotating the cover
90º clockwise.
4. Replace the diffuser over the impeller, using care to insert alignment pins into the correct holes.
The molded-in arrow must point toward the handle of the backplate.
5. Replace the two (2) small Phillips head screws.
Tighten the screws to draw the diffuser against the motor backplate. For 5.0HP, SWF models only, use additional lock washers. See Figure 12.
6. Make sure the diffuser o-ring, o-ring groove, and o-ring seal area are clean and free of debris, which could cause a leak. If you removed the diffuser o-ring, install it into the groove you removed it from, see Figures 7 and 8. If grease is used to retain the o-ring, it must be silicone based. Do not use petroleum-based grease. It will destroy the o-ring.
7. Slide the diffuser into the mating hole in the pump body. While supporting the motor, start two (2)screws on opposite sides. This will hold the motor in position while you start the other six
(6) screws.
8. Tighten the screws lightly in a crossing “X” pattern using a 9/16" wrench, starting with the inner (middle) four (4) then the outer (top and bottom) four (4) to draw the backplate to the body in an even manner. Once all the screws are snug, torque in the same order to 18 foot-pounds.
Carbon Seal Surface
ENGLISH
9. If the pump is located above water level of the pool, remove the lid and fill the basket with water before starting the pump.
notE Prior to replacing the lid, check for debris around the lid o-ring seat, as this will cause air leaks into the system.
10. Hand-tighten the lid to make an air tight seal. Do not use any tools to tighten the lid.
11. Open the pressure release valve on the filter, and make sure it is clean and ready for operation.
12. Switch on the circuit breaker to the pump motor.
13. Turn on the pump and check the system for normal operation.
14. Once all the air has left the filter, close the pressure release valve.
6.2.4 Mechanical Seal replacement notE This is a two part replacement process. The mechanical seal must be replaced as a set.
notE Refer to Figure 12 for an illustration of the location of the mechanical seal and impeller.
Warning
Page 17
Do not damage the ceramic or carbon surfaces of the seals. If surfaces are damaged, leaks will occur.
1.
3.
To access the mechanical seal, follow steps 1 through 8 of Section 6.2.2, Impeller Removal.
2. Remove the carbon face seal half, see Figure
11 from the motor shaft. This is a spring-loaded seal. Grasp the portion of the seal closest to the impeller body and pull the seal off using a twisting motion.
Remove the motor from the backplate following the steps in Section 6.2.5, Motor Replacement.
Backplate Self Sealing Left
Handed Screw
Impeller
Diffuser
Screws and
Washers (2)
• Ceramic Face Seal
• Backplate Seal
• Carbon Face/ Spring
Side of Seal
• Impeller Side of the
Mechanical Seal
Figure 11. replace the Mechanical Seal
Mechanical Seal
Lock Washers (2)
For 5.0HP SHP &
SWF Models Only
Diffuser O-ring
Figure 12. Backplate, impeller, diffuser, and
Mechanical Seal Exploded View
Page 18
ENGLISH Jandy ® Pro Series Stealth ™ Pumps | Operation Manual
4. Place the backplate o-ring side down and force the ceramic seal out using a screwdriver or drift.
5. Turn the backplate o-ring side up and insert the new ceramic seal side into the backplate. Use great care to press the seal in squarely with your fingers. The ceramic is easily damaged and must be pressed in using only your fingers or soft tools. Do not use any lubricant other than water and soap solution.
6. Install the motor following the steps in
Section 6.2.5, Motor Replacement.
7. Install the backplate following the steps in
Section 6.2.3, Impeller Replacement.
6.2.5 Motor replacement
Caution
To ensure continued safety and reliable operation,
Zodiac Pool Systems, Inc. requires that you replace the motor with a motor that has the identical HP rating and service factor (Zodiac Pool Systems, Inc. approved only).
Warning
To avoid the risk of property damage, severe personal injury, or death, turn off the pump and switch off the circuit breaker to the pump motor before beginning this procedure.
3. Place the backplate motor assembly o-ring side down and unscrew the four (4) 9/16" screws and remove the motor. notE Before removing the backplate, note the alignment of the backplate to the motor. See Figure 13.
4. If installing a new motor, remove the protective plastic cap from the motor shaft. Place the motor on the backplate so that the opening in the motor faces the bottom of the backplate. The starting capacitor on the motor should be at the
12 o'clock position.
5. Replace the four (4) bolts and washers holding the backplate to the motor.
6. To reassemble the pump after replacing the motor, follow steps 1 through 14 of Section 6.2.3,
Impeller Replacement.
7. Have a qualified service technician or electrician properly connect the electrical wiring at the pump motor.
notE Zodiac Pool Systems, Inc. recommends that the mechanical seals be replaced at the same time the motor is replaced. See Section 6.2.4, Mechanical Seal
Replacement, for details.
1. Have a qualified service technician or electrician properly disconnect the electrical wiring at the pump motor.
2. To disassemble the pump housing from the motor, follow steps 1 through 8 in Section 6.2.2,
Impeller Removal.
Backplate
Bolts and
Washers (4)
Starting
Capacitor
Motor
Figure 13. Backplate assembly
Jandy ® Pro Series Stealth ™ Pumps | Operation Manual ENGLISH
Section 7. Product Specifications and Technical Data
Page 19
7.1 replacement Parts list
To order or purchase parts for Zodiac
® pumps, contact your nearest Zodiac dealer. If they cannot supply you with what you need, contact Zodiac technical support at 800.822.7933 or send an e-mail message to:
Key no.
1
3
3
3
3
3
3
3
3
3
3
3
3
3
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1 description
Single-speed Motor & Hardware, SHPF
Single-speed Motor & Hardware, SHPF
Single-speed Motor & Hardware, SHPF
Single-speed Motor & Hardware, SHPF
Single-speed Motor & Hardware, SHPF
Single-speed Motor & Hardware, SHPF
Single-speed Motor & Hardware, SHPF
Single-speed Motor & Hardware, SHPM
Single-speed Motor & Hardware, SHPM
Single-speed Motor & Hardware, SHPM
Single-speed Motor & Hardware, SHPM
Single-speed Motor & Hardware, SHPM
Two-speed Motor & Hardware, SHPM
Two-speed Motor & Hardware, SHPM
Two-speed Motor & Hardware, SHPM
Single-speed Motor & Hardware, SHPF, 3 Phase
Single-speed Motor & Hardware, SHPF, 3 Phase
Single-speed Motor & Hardware, SHPF, 3 Phase
Single-speed Motor & Hardware, SHPF, 3 Phase
Two-speed Motor & Hardware, SHPF
Two-speed Motor & Hardware, SHPF
Two-speed Motor & Hardware, SHPF
Backplate Kit w/Hardware, O-ring & Mech Seals, SHPF/SHPM
Backplate Kit w/Hardware, O-ring & Mech Seals, SHPF
Impeller & Diffuser w/Screw & O-ring, SHPF
Impeller & Diffuser w/Screw & O-ring, SHPF
Impeller & Diffuser w/Screw & O-ring, SHPF
Impeller & Diffuser w/Screw & O-ring, SHPF
Impeller & Diffuser w/Screw & O-ring, SHPF
Impeller & Diffuser w/Screw & O-ring, SHPF
Impeller & Diffuser w/Screw & O-ring, SHPF
Impeller & Diffuser w/Screw & O-ring, SHPM
Impeller & Diffuser w/Screw & O-ring, SHPM
Impeller & Diffuser w/Screw & O-ring, SHPM
Impeller & Diffuser w/Screw & O-ring, SHPM
Impeller & Diffuser w/Screw & O-ring, SHPM
Screw w/O-ring, Self-sealing order Part no.
R0445114
R0445101
R0445102
R0445103
R0445104
R0445105
R0490200
R0479301
R0479302
R0479303
R0479304
R0479305
R0479307
R0479308
R0479309
R0479101
R0479102
R0479103
R0479104
R0445113
R0445106
R0445107
R0445200
R0445201
R0445301
R0445302
R0445303
R0445304
R0445305
R0445306
R0445307
R0445301
R0445302
R0445303
R0445304
R0445305
R0445302-06
Model no.
(HP)
.50
.50
.75
1.0, 1.0-2
1.5, 1.5-2
2.0, 2.0-2
3.0
5.0
0.75
1.0
1.5
2.0, 2.0-2
2.5, 2.5-2
All
2.5
1.0
1.5
2.0
3.0
1.0
1.5
2.0
.50-3.0
5.0
3.0
5.0
.75
1.0
.75
1.0
1.5
2.0
1.5
2.0
2.5
1.5
2.0
Page 20
ENGLISH Jandy ® Pro Series Stealth ™ Pumps | Operation Manual
15
16
16
17
10
11
12
12
13
14
18
19
7
8
9
5
6
Key no.
4
4 description
Diffuser w/O-ring & Hardware
Diffuser w/O-ring & Hardware
Mechanical Shaft Seal (1 Set) (Carbon and Ceramic)
Body, Pump, SHPF/SHPM
Motor Mounting Foot Assembly w/Screws, SHPF/SHPM
Lid w/ Locking Ring & Seal
Blue Pressure Test O-ring
Pump Debris Filter Basket
Drain Plug w/O-ring (Set of 2)
Tail Piece (2" by 2½"), O-ring & Coupling Nut (Set of 2)
Tail Piece (2½" by 3") with O-ring and Coupling Nut (Set of 2)
Lid Seal and Lid O-ring (Lid O-ring Not Shown)
O-ring, Backplate
O-ring, Tail Piece (Set of 2)
Hardware, Diffuser/Impeller
Hardware, Diffuser/Impeller
Backplate Bolts and Washers (Set of 8)
Motor Bolts and Washers (Set of 4)
Screws, Motor Mounting Foot
Model no.
(HP)
.50-3.0
5.0
All
All
.50-2.5
3.0-5.0
All
All
All
.50-3.0
5.0
All
All
All
All
All
All
All
All order Part no.
R0445400
R0445401
R0479400
R0445601
R0445700
R0445800
R0479000
R0445900
R0446000
R0446101
R0446102
R0446200
R0446300
R0446400
R0446500
R0446501
R0446600
R0446700
R0446800
8
13
9
10
7.2 Exploded View
11 (qty 2)
15
12
4 (qty 2),
16 (qty 2)
4 (qty 2),
16 (qty 2)
3, 16
15
12
6
4 (qty 2),
16 (qty 2)
3, 4
3
2, 5
2
2 (qty 8),
17 (qty 8)
1 (qty 4),
18 (qty 4)
1
2, 14
7 (qty 2),
19 (qty 2)
7
Figure 14. SHPF and SHPM Exploded View
Jandy ® Pro Series Stealth ™ Pumps | Operation Manual
7.3 SHPF and SHPM Pump Curves
ENGLISH
Page 21
Jandy Stealth ™ Series High Head Pumps
Full-Rated (SHPF) and Max-Rated (SHPM)
120
110
50
45
100
90
40
80
SHPF 5.0
35
70
30
60
50
40 SHPF 2.0/
SHPM 2.5
Low Speed
SHPF .50/
SHPM .75
SHPF 2.0/
SHPF 2.0-3PH/
SHPM 2.5
SHPF 3.0/
SHPF 3.0-3PH
25
20
15
30
20
10
0
SHPF 1.0/
SHPF 1.0-3PH/
SHPM 1.5
SHPF 1.5/
SHPF 1.5-3PH/
SHPM 2.0
10
SHPF 1.5/
SHPM 2.0
Low Speed
SHPF .75/
SHPM 1.0
5
SHPF 1.0/
Low Speed
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250
0
Flow Rate, Gallons Per Minute (GPM)
Page 22
ENGLISH Jandy ® Pro Series Stealth ™ Pumps | Operation Manual
7.4 Physical and Operational Specifications
7.4.1 SHPF Pump Specifications
Model no.
SHPF .50
SHPF .75
SHPF 1.0
SHPF 1.5
SHPF 2.0
SHPF 3.0
SHPF 1.0-2SPD
SHPF 1.5-2SPD
SHPF 2.0-2SPD
SHPF 1.0-3PH
SHPF 1.5-3PH
SHPF 2.0-3PH
SHPF 3.0-3PH
SHPF 5.0
2.0
2.5
1.0
1.5
2.0
3.0
5.0
1.5
2.0
3.0
1.0
HP
.50
.75
1.0
Voltage amps
208-230/115 4.4-4.5/8.8
208-230/115 6.0-5.6/11.2
208-230/115 7.8-7.4/14.8
208-230
208-230
208-230
230
9.6-8.8
11.0-10.0
15.0-13.6
7.2/3.0
230
230
10.0/3.5
11.0/4.0
208-230/460 5.0-4.6/2.3
208-230/460 6.4-5.8/2.9
208-230/460 7.1-6.8/3.4
208-230/460 9.0-8.6/4.3
230 19.4
Pipe Size
2-2½"
2-2½"
2-2½"
2-2½"
2-2½"
2½-3"
2-2½"
2-2½"
2-2½"
2-2½"
2-2½"
2-2½"
2½-3"
4"
Carton Weight overall length 'a'
30 lbs.
43 lbs.
31 1 /
8
31 7 /
8
"
"
45 lbs.
32¼"
50 lbs.
57 lbs.
63 lbs.
52 lbs.
57 lbs.
64 lbs.
55 lbs.
57 lbs.
64 lbs.
62 lbs.
68 lbs.
32 5 /
8
"
33 1 /
8
"
33 1 /
8
"
33 1 /
8
"
33 5 /
8
"
33 1 /
8
"
31 7 /
8
"
32 1 /
8
"
32 5 /
8
"
32 5 /
8
"
33¾"
7.4.2 SHPM Pump Specifications
Model no.
SHPM .75
SHPM 1.0
SHPM 1.5
SHPM 2.0
SHPM 2.5
SHPM 1.5-2SPD
SHPM 2.0-2SPD
SHPM 2.5-2SPD
HP
.75
1.0
1.5
2.0
2.5
1.5
2.0
2.5
Voltage amps
208-230/115 4.4-4.5/8.8
208-230/115 6.0-5.6/11.2
208-230/115 7.8-7.4/14.8
208-230
208-230
9.6-8.8
11.0-10.0
230
230
230
7.2/3.0
10.0/3.5
11.0/4.0
Pipe Size Carton Weight overall length 'a'
2-2½" 30 lbs.
31 1 /
8
"
2-2½"
2-2½"
43 lbs.
45 lbs.
31 7 /
8
32¼"
"
2-2½"
2-2½"
2-2½"
2-2½"
2-2½"
50 lbs.
57 lbs.
52 lbs.
57 lbs.
64 lbs.
32 5 /
8
"
33 1 /
8
"
32 1 /
8
"
32 5 /
8
"
33 1 /
8
"
7.4.3 Pump dimensions
Jandy ® Pro Series Stealth ™ Pumps | Operation Manual
'a'
11 3 /
8
" 16 1 /
8
"
ENGLISH
Page 23
10 3 /
8
"
15¼"
10 3 /
8
"
9"
Bolt Holes,
Center to Center
14¾"
Front Edge of union to Center of Bolt Holes notE When installing pump, leave a minimum of two feet (2 ft) of clearance above the pump for removal of strainer basket.
7.5 SHP replacement Motor guide
SHPF Pumps
Pump Model
SHPF .50
SHPF .75
SHPF 1.0
SHPF 1.5
SHPF 2.0
SHPF 3.0
a.o Smith /
Century
B845
B661, B2661
B841, B2841
B842, B2842
B843, B2843
B844, B2844
SHPF 1.0-3PH H635
SHPF 1.5-3PH H636
SHPF 2.0-3PH H637
SHPF 3.0-3PH H755
SHPF 1.0-2SPD B982, B2982
SHPF 1.5-2SPD B983, B2983
SHPF 2.0-2SPD B984, B2984
SHPF 5.0
B1000
SHPM Pumps
Pump Model
SHPM 1.0
SHPM 1.5
SHPM 2.0
SHPM 2.5
a.o Smith/
Century
B863SE
B864SE
B865SE
B866SE
SHPM 1.5 2SPD B982, B2982
SHPM 2.0 2SPD B983, B2983
SHPM 2.5 2SPD B984, B2984
CONFORMS TO UL 1081
CERTIFIED TO CSA C22.2 NO 108
Zodiac Pool Systems, Inc.
2620 Commerce Way, Vista, CA 92081
1.800.822.7933 | www.ZodiacPoolSystems.com
ZODIAC ® is a registered trademark of Zodiac International, S.A.S.U., used under license.
All trademarks referenced herein are the property of their respective owners.
©2012 Zodiac Pool Systems, Inc. H0573800 Rev J 1204
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement