Product information | Zodiac Jandy Pro Series Product specifications


Add to my manuals
24 Pages

advertisement

Product information | Zodiac Jandy Pro Series Product specifications | Manualzz

inStallation and oPEration Manual

EngliSH

Jandy Pro Series Stealth

Pumps

Models SHPF and SHPM

Warning

For Your SaFEtY - this product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist. the maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product.

Failure to follow warning notices and instructions may result in property damage, personal injury, or death. improper installation and/or operation will void the warranty.

improper installation and/or operation can create unwanted electrical hazard which can cause serious injury, property damage, or death. attEntion inStallEr - this manual contains important information about the installation, operation and safe use of this product. this information should be given to the owner/operator of this equipment.

Page 2

ENGLISH Jandy ® Pro Series Stealth ™ Pumps | Operation Manual

Jandy ® Pro Series Stealth ™ Pumps | Operation Manual ENGLISH

Page 3

table of Contents

Section 1. iMPortant SaFEtY inStruCtionS .................................................4

1.1 Safety Instructions ................................................ 4

1.2 Pool Pump Suction Entrapment

Prevention Guidelines .......................................... 6

Section 2. general description .........................7

2.1 Introduction ........................................................... 7

2.2 Description ........................................................... 7

Section 7. Product Specifications and technical data ................................19

7.1 Replacement Parts List ...................................... 19

7.2 Exploded View .................................................... 20

7.3 SHPF and SHPM Pump Curves ......................... 21

7.4 Physical and Operational Specifications ............ 22

7.5 SHP Replacement Motor Guide ......................... 23

Section 3. installation .........................................8

3.1 Plumbing .............................................................. 8

3.2 Electrical Installation ............................................. 9

3.3 Pressure Testing ................................................. 10

Section 4. operation .........................................12

4.1 Start-up ............................................................... 12

Section 5. Service and Maintenance ...............13

5.1 Routine Maintenance ......................................... 13

5.2 Winterizing the Pump ......................................... 13

Section 6. troubleshooting and repair ..........14

6.1 Troubleshooting .................................................. 14

6.2 Service Technician Maintenance ........................ 15

EquiPMEnt inForMation rECord

datE oF inStallation inStallEr inForMation initial PrESSurE gaugE rEading (WitH ClEan FiltEr)

PuMP ModEl HorSEPoWEr notES:

Page 4

ENGLISH Jandy ® Pro Series Stealth ™ Pumps | Operation Manual

Section 1. iMPortant SaFEtY inStruCtionS rEad and FolloW all inStruCtionS

1.1 Safety instructions

All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes.

When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:

Warning riSK oF SuCtion EntraPMEnt HaZard, WHiCH, iF not aVoidEd, Can rESult in SEriouS inJurY

or dEatH. Do not block pump suction as this can cause severe injury or death. Do not use this pump for wading pools, shallow pools or spas containing bottom drains, unless the pump is connected to at least two functioning suction outlets. Suction outlet (drain) covers must be certified to the latest published version of ANSI/

ASME A112.19.8.

Warning

To reduce the risk of injury, do not permit children to use this product.

Warning

To reduce the risk of property damage or injury, do not attempt to change the backwash (multiport, slide, or full flow) valve position with the pump running.

Warning

Zodiac ® pumps are powered by a high voltage electric motor and must be installed by a licensed or certified electrician or a qualified swimming pool service technician.

Warning

riSK oF ElECtriC SHoCK, FirE, PErSonal inJurY, or dEatH. Connect only to a branch circuit that is protected by a ground-fault circuit-interrupter (GFCI). Contact a qualified electrician if you cannot verify that the circuit is protected by a GFCI. Make sure such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the pump without the test button being pushed, a ground current is flowing, indicating the possibility of electrical shock. Do not use the pump. Disconnect the pump and have the problem corrected by a qualified service representative before using.

Due to the potential risk of fire, electric shock, or injuries to persons, Zodiac Pumps must be installed in accordance with the National Electric Code (NEC), all local electrical and safety codes, and the Occupational

Safety and Health Act (OSHA). Copies of the NEC may be ordered from the National Fire Protection Association online at www.nfpa.org or call 617-770-3000, or contact your local government inspection agency.

Warning

Incorrectly installed equipment may fail, causing severe injury or property damage.

Jandy ® Pro Series Stealth ™ Pumps | Operation Manual ENGLISH

Page 5

Warning

• Do not connect the system to an unregulated city water system or other external source of pressurized water producing pressures greater than 35 PSI.

• Trapped air in system can cause the filter lid to be blown off, which can result in death, serious personal injury, or property damage. Be sure all air is out of the system before operating.

Warning

To minimize the risk of severe injury or death the filter and/or pump should not be subjected to the piping system pressurization test.

Local codes may require the pool piping system to be subjected to a pressure test. These requirements are generally not intended to apply to the pool equipment such as filters or pumps.

Zodiac ® pool equipment is pressure tested at the factory.

However, if the WARNING cannot be followed and pressure testing of the piping system must include the filter and/or pump, BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS:

• Check all clamps, bolts, lids, lock rings and system accessories to ensure they are properly installed and secured before testing.

• RELEASE ALL AIR in the system before testing.

• Water pressure for test must NOT EXCEED 35 PSI.

• Water temperature for test must NOT EXCEED 100°F (38°C).

• Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.

notice: These parameters apply to Zodiac equipment only. For non-Zodiac equipment, consult equipment manufacturer.

Warning

Chemical spills and fumes can weaken pool/spa equipment. Corrosion can cause filters and other equipment to fail, resulting in severe injury or property damage. Do not store pool chemicals near your equipment.

Caution

do not start pump dry! Running the pump dry for any length of time will cause severe damage and will void the warranty.

Caution

This pump is for use with permanently installed pools and may also be used with hot tubs and spas if so marked.

Do not use with storable pools. A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage. A storable pool is constructed so that it may be readily disassembled for storage and reassembled to its original integrity.

Caution

Do not install within an outdoor enclosure or beneath the skirt of a hot tub or portable spa. The pump requires adequate ventilation to maintain air temperature at less than the maximum ambient temperature rating listed on the motor rating plate.

Page 6

ENGLISH Jandy ® Pro Series Stealth ™ Pumps | Operation Manual

1.2 Pool Pump Suction Entrapment Prevention guidelines

Caution

The 3-phase SHPF series pumps utilize non-thermally protected motor assemblies. NRTL Listed Motor Controller with internal motor running overload protection or external motor running overload are required during the final installation of the pump assembly. Overloads shall be set at a maximum of 125% of the full-load current rating of the pump motor assembly.

Warning

SuCtion HaZard. Can cause serious injury or death. do not use this pump for wading pools, shallow pools or spas containing bottom drains, unless the pump is connected to at least two (2) functioning suction outlets.

Warning

Pump suction is hazardous and can trap and drown or disembowel bathers. do not use or operate

swimming pools, spa, or hot tubs if a suction outlet cover is missing, broken, or loose. The following guidelines provide information for pump installation that minimizes the risk of injury to users of pools, spas, and hot tubs:

Entrapment Protection - The pump suction system must provide protection against the hazards of suction entrapment.

Suction outlet Covers - All suction outlets must have correctly installed, screw-fastened covers in place. All suction outlet (drain) covers must be maintained. Drain covers must be listed/certified to the latest version of

ANSI/ASME A112.19.8. They must be replaced if cracked, broken, or missing.

number of Suction outlets Per Pump - Provide at least two (2) hydraulically-balanced main drains, with covers, as suction outlets for each circulating pump suction line. The centers of the main drains (suction outlets) on any one (1) suction line must be at least three (3) feet apart, center to center. See Figure 1 on page 7.

The system must be built to include at least two (2) suction outlets (drains) connected to the pump whenever the pump is running. However, if two (2) main drains run into a single suction line, the single suction line may be equipped with a valve that will shut off both main drains from the pump. The system shall be constructed such that it shall not allow for separate or independent shutoff or isolation of each drain. See Figure 1 on page 7.

More than one (1) pump can be connected to a single suction line as long as the requirements above are met.

Water Velocity - The maximum water velocity through the suction fitting or cover for any suction outlet must be

1.5 feet per second unless the outlet complies with the latest version of ANSI/ASME A112.19.8, the standard for

Suction Fittings For Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs. In any case, do not exceed the suction fitting’s maximum designed flow rate.

If 100% of the pump’s flow comes from the main drain system, the maximum water velocity in the pump suction hydraulic system must be 6 feet per second or less, even if one (1) main drain (suction outlet) is completely blocked. The flow through the remaining main drain(s) must comply with the latest version of ANSI/ASME

A112.19.8, the standard for Suction Fittings For Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs.

testing and Certification - Suction outlet covers must have been tested by a nationally recognized testing laboratory and found to comply with the latest version of ANSI/ASME A112.19.8, the standard for Suction Fittings

For Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs.

Fittings - Fittings restrict flow; for best efficiency use fewest possible fittings (but at least two (2) suction outlets).

Avoid fittings which could cause an air trap.

Pool cleaner suction fittings must conform to applicable International Association of Plumbing and Mechanical

Officials (IAPMO) standards.

SaVE tHESE inStruCtionS

Jandy ® Pro Series Stealth ™ Pumps | Operation Manual ENGLISH

At least three (3) feet

Listed/certified to latest published version of

ANSI/ASME

A112.19.8 - 2007

Anti-entrapment

Cover/Grate or Suction

Fitting, screw-fastened

to Main Drain Sump

Suction Outlet

(Main Drain)

No valves between

Tee and Main Drains

Valves OK between pump and Tee

Listed/certified to latest published version of

ANSI/ASME

A112.19.8 - 2007

Anti-entrapment

Cover/Grate or Suction

Fitting, screw-fastened

to Main Drain Sump

Suction Outlet

(Main Drain)

Pump

Page 7

Figure 1. number of Suction outlets Per Pump

Section 2. general description

2.1 introduction

This manual contains information for the proper installation, operation and maintenance of Jandy Pro

Series Stealth (SHP) Pumps. Procedures in this manual must be followed exactly. To obtain additional copies of this manual contact Zodiac Pool Systems, Inc. ("Zodiac") at 800.822.7933. For address information, see the back cover of this manual.

2.2 description

SHP Pumps are designed to meet the needs of today’s more hydraulically demanding pool equipment. The pump housing, backplate, diffuser, hair and lint pot

(pump debris filter basket), and impeller are all made from high quality thermoplastic materials. These materials were chosen for their strength and corrosion resistance.

The pump is driven by an electric motor directly attached to the pump impeller. As the electric motor turns, it causes the impeller to turn, which forces water to flow through the pump. The water flows through the pump inlet and then into the filter basket. The basket assembly pre-strains and traps large particles. The water then enters the center of the pump housing, flows through the impeller into the diffuser, and then flows out the pump discharge port.

Page 8

ENGLISH

Section 3. installation

3.1 Plumbing

3.1.1 Preparation

1. Upon receipt of the pump, check the carton for damage. Open the carton and check the pump for concealed damage, such as cracks, dents or a bent base. If damage is found, contact the shipper or distributor where you purchased the pump.

2. Inspect the contents of the carton and verify that all the parts are included. See Section 7.1,

Replacement Parts List.

Jandy ® Pro Series Stealth ™ Pumps | Operation Manual

5. The pump foundation must have adequate drainage to prevent the motor from getting wet.

The pump needs to be protected from the rain and sun.

6. Proper ventilation is required for the pump to operate normally. All motors generate heat that must be removed by providing proper ventilation.

7. Provide access for future service by leaving a clear area around the pump. Allow plenty of space above the pump to remove the lid and basket for cleaning.

8. If the equipment is under cover, provide adequate lighting.

3.1.2 Pump location

1. Zodiac Pool Systems, Inc. recommends installing the pump within one (1) foot above the water level. The pump should not be elevated more than a few feet above the water level of the pool.

A check valve is recommended on the suction line to the pump.

notE Better self-priming will be achieved if the pump is installed as close as possible to the water level of the pool.

2. If the pump is located below water level, isolation valves must be installed on both the suction and return lines to prevent back flow of pool water during any routine or required servicing.

Warning

Some Safety Vacuum Release System (SVRS) devices are not compatible with installation of check valves. If the pool has an SVRS device, be sure to confirm that it will continue to safely operate when any check valves are installed.

3. The pump and other circulation equipment must be located more than five (5) feet from the water.

Choose a location that will minimize turns in the piping. notE In Canada, the pump must be located a minimum of three (3) meters [approximately ten (10) feet] from the water (CSA C22.1).

4. The pump must be placed on a solid foundation that will not vibrate. To further reduce the possibility of vibration noise, bolt the pump to the foundation.

notE Zodiac Pool Systems, Inc. recommends bolting the pump directly to the foundation.

3.1.3 Pipe Sizing notE All HP ratings given in this section apply to full-rated pumps. For help with max-rated pumps, contact

Zodiac Technical Support at 800.822.7933.

3.1.3.1 Suction Pipe

When the pump is located up to 50 feet from the pool, the recommended minimum pipe size for the suction side of the pump is:

• 2" for .75 to 1.5 HP*

• 2½" for 2.0 HP*

• 3" for 3.0 HP*

• 4" for 5.0 HP*

* HP refers to full-rated pumps

3.1.3.2 discharge Pipe

When the pump is located up to 50 feet from the pool, the recommended minimum pipe size for the discharge side of the pump is:

• 2" for .75 to 1.5 HP*

• 2½" for 2.0 HP*

• 3" for 3.0 HP*

• 4" for 5.0 HP*

* HP refers to full-rated pumps

notE All pipe sizes are able to withstand the pressures the pump will deliver, but not necessarily the flow. If the pipe is too small for the pump, or it is elevated above water, the maximum gallons per minute (GPM) may not be delivered. If this happens, the pump will develop an air pocket (cavitation) that will make noise and the pump life will be shortened.

3.1.3.3

1. If the pump is located below water level, isolation valves must be installed on both sides

2. To help prevent difficulty in priming, install the suction pipe without high points (above inlet of pump - inverted “U”s in plumbing), which can trap air. For installations of equipment up to 100 feet from the water, refer to the pipe sizing chart,

Table 1. For installations of equipment more than

100 feet from the water, the recommended pipe must be increased to the next size.

table 1. Pipe Sizing Chart for Schedule 40 PVC

Pipe

Size

1½"

2"

Maximum Flow

Suction

(8 feet per second)

Maximum Flow discharge

(10 feet per second)

50 GPM (189 LPM) 65 GPM (246 LPM)

85 GPM (322 LPM) 105 GPM (397 LPM)

2½" 120 GPM (454 LPM) 149 GPM (564 LPM)

3" 184 GPM (697 LPM) 230 GPM (871 LPM)

4" 317 GPM (1203 LPM) 397 GPM (1502 LPM)

3.

Jandy ® Pro Series Stealth ™ Pumps | Operation Manual installation recommendations of the pump to prevent back flow of pool water during any routine or required servicing.

SHP Pumps come equipped with unions on both the suction and discharge ports. This feature simplifies installation and service, and eliminates the possibility of leaks at threaded adapters.

4. The SHP Pump must be connected to at least two

(2) hydraulically balanced main drains (suction outlets) for each pool pump suction line. Each drain must be provided with covers that are listed or certified to the latest version of ANSI/ASME

A112.19.8. The suction outlets of the main drains must be at least three (3) feet apart or at different planes. The suction outlets can be a drain and skimmer, two (2) drains, two (2) skimmers, or a skimmer with an equalizer line installed. Check the local codes for proper installation requirements.

notE To prevent entrapment, the system must be built so that it cannot operate with the pump drawing water from only one (1) main drain. At least two (2) main drains must be connected to the pump when it is in operation. However, if two (2) main drains run into a single suction line, the single suction line may be equipped with a valve which will shut off both main drains from the pump.

5. The piping must be well supported and not forced together where constant stress will be experienced.

6. Always use properly sized valves. Jandy Pro

Series Diverter Valves and Ball Valves typically have the best flow capabilities.

7. Use the fewest fittings possible. Every additional fitting has the effect of moving the equipment farther away from the water. notE If more than 10 suction fittings are needed, the pipe size must be increased.

8. If this is a new installation, pressure test according to local codes. See Section 3.3,

Pressure Testing.

3.2 Electrical installation

3.2.1 Voltage Checks

The correct voltage, as specified on the pump data plate, is necessary for proper performance and long motor life.

Incorrect voltage will decrease the pump’s ability to perform and could cause overheating, reduce the motor life, and result in higher electric bills.

It is the responsibility of the electrical installer to provide data plate operating voltage to the pump by ensuring proper circuit sizes and wire sizes for this specific application.

ENGLISH

The National Electrical Code (NEC, NFPA-70) requires all pool pump circuits be protected with a Ground Fault

Interrupter (GFCI). Therefore, it is also the responsibility of the electrical installer to ensure that the pump circuit is in compliance with this and all other applicable requirements of the National Electrical Code (NEC) and any other applicable installation codes.

Caution

Page 9

Failure to provide data plate voltage (within 10%) during operation will cause the motor to overheat and void the warranty.

3.2.2 Bonding and grounding

1. The motor frame must be grounded to a reliable grounding point using a solid copper conductor,

No. 8 AWG or larger. In Canada, No. 6 AWG or larger must be used. If the pump is installed within five (5) feet of the inside walls of the swimming pool, spa, or hot tub, the motor frame must be bonded to all metal parts of the swimming pool, spa, or hot tub structure and to all electrical equipment, metal conduit, and metal piping within five (5) feet of the inside walls of the swimming pool, spa, or hot tub.

2. Bond the motor using the provided external lug.

Page 10

ENGLISH

Warning

To avoid the risk of property damage, severe personal injury, and/or death, always disconnect the power source before working on a motor or its connected load.

Warning

To avoid the risk of property damage, severe personal injury, and/or death, make sure that the control switch or time clock is installed in an accessible location so that in the event of an equipment failure or a loose plumbing fitting the equipment can be turned off. This location must not be in the same area as the pool pump, filter, and other equipment.

Warning

The pump must be permanently connected to a dedicated electrical circuit. No other equipment, lights, appliances or outlets may be connected to the pump circuit, with the exception of devices that may be required to operate simultaneously with the pump, such as a chlorinating device or heater.

Jandy ® Pro Series Stealth ™ Pumps | Operation Manual

2. Wire size must be adequate to minimize voltage drop during the start-up and operation of the pump. See Table 2 for recommended wire sizes.

3. Insulate all connections carefully to prevent grounding or short-circuits. Sharp edges on terminals require extra protection. To prevent wire nuts from loosening, tape them using a suitable, listed (UL, ETL, CSA) electrical insulating tape.

For safety, and to prevent entry of contaminants, reinstall all conduit and terminal box covers. Do not force connections into the conduit box.

4. To configure the internal wiring of the pump motor for the correct voltage, refer to the diagram on the motor data plate.

3.3 Pressure testing

All model SHP pumps come with an additional disposable o-ring for pressure testing. This is the blue pressure test o-ring. See Figures 2 and 3.

3.2.3 Electrical Wiring

1. The pump motor must be securely and adequately grounded using the green screw provided. Ground before attempting to connect to an electrical power supply. Do not ground to a gas supply line.

Caution

Do not open the pump lid before pressure testing, because the blue pressure test o-ring may fall out. If this happens, you will need to replace it.

If you have not opened the pump lid, skip to Section

3.3.2, Conduct Pressure Test.

table 2. recommended Minimum Wire Size

rECoMMEndEd MiniMuM WirE SiZE For SHP PuMPS*

distance from Sub-Panel 0-50 Feet 50-100 Feet 100-150 Feet

Pump Model

Branch Fuse aMPs

Class: CC, g, H, J, K, rK, or t

Voltage Voltage Voltage

150-200 Feet

Voltage

SHPF .50HP/SHPM .75HP

SHPF .75HP/SHPM 1.0HP

SHPF 1.0HP/SHPM 1.5HP

SHPF 1.0-3PH

SHPF 1.5HP/SHPM 2.0HP

SHPF 1.5-3PH

SHPF 2.0HP/SHPM 2.5HP

SHPF 2.0-3PH

SHPF 3.0HP

SHPF 3.0-3PH

230VaC 115VaC

15A

15A

15A

15A

15A

15A

15A

15A

20A

15A

15A

15A

20A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

208-230 VaC 115 VaC 208-230 VaC 115 VaC 208-230 VaC 115 VaC 208-230 VaC 115 VaC

14

14

12

12

12

12

8

8

10

10

6

6

8

8

6

6

12

14

12

12

10

N/A

N/A

N/A

10

12

10

10

8

N/A

N/A

N/A

8

10

8

8

6

N/A

N/A

N/A

6

8

6

6

4

N/A

N/A

N/A

12

12

10

12

N/A

N/A

N/A

N/A

8

10

8

8

N/A

N/A

N/A

N/A

6

8

6

6

N/A

N/A

N/A

N/A

6

6

4

6

N/A

N/A

N/A

N/A

SHPF 5.0

SHPF 1.0HP-2-SPD (1)

SHPF 1.5HP-2-SPD (1)

SHPF 2.0HP-2-SPD (1)

25A

15A

15A

15A

N/A

N/A

N/A

N/A

10

12

12

12

N/A

N/A

N/A

N/A

8

10

10

8

N/A

N/A

N/A

N/A

6

8

8

6

N/A

N/A

N/A

N/A

6

6

6

6

N/A

N/A

N/A

N/A

SHPM 1.5HP-2-SPD (1)

SHPM 2.0HP-2-SPD (1)

SHPM 2.5HP-2-SPD (1)

15A

15A

15A

N/A

N/A

N/A

12

12

12

N/A

N/A

N/A

10

10

8

N/A

N/A

N/A

8

8

6

N/A

N/A

N/A

6

6

6

N/A

N/A

N/A

*Assumes three (3) copper conductors in a buried conduit and 3% maximum voltage loss in branch circuit. All National Electrical Code (NEC) and local codes must be followed. Table shows minimum wire size and branch fuse recommendations for a typical installation per NEC.

(1) Two-speed pumps are not rated for use with 208 VAC.

Lid with

Locking

Ring and

Seal

Blue

Pressure

Test

O-ring

Pump

Debris

Trap

Basket

(Inside

Pump)

Figure 2. Exploded View of Pump

Lid with

Locking

Ring

Jandy ® Pro Series Stealth ™ Pumps | Operation Manual ENGLISH

Page 11

3.3.1.1 remove Pump lid

1. Make sure that the pump is turned off.

2. Make sure that the switch to the circuit breaker that powers the pump motor is turned off.

Warning

Turn off the pump and the main breaker in the pump electrical circuit before starting the procedure. Failure to comply may cause a shock hazard, resulting in severe personal injury or death.

Warning

Due to the potential risk of fire, electric shock, or injuries to persons, Jandy Pro Series Pumps must be installed in accordance with the National Electrical

Code ® (NEC), in the USA, or the Canadian Electrical

Code (CEC) in Canada. All applicable local codes must also be followed.

The NEC may be obtained by contacting the

National Fire Protection Association (NFPA) at

1-800-344-3555 or 1-617-770-3000.

Seal

3. Make sure all necessary isolation valves are closed to prevent pool water from reaching the pump.

4. Following the markings on the locking ring, turn the ring counter-clockwise until the ‘START’ markings align with the ports.

5. Carefully remove the lid with locking ring.

Blue Pressure Test O-ring

Figure 3. Blue Pressure test o-ring in lid assembly

3.3.1 replace Blue Pressure test o-ring if necessary

If you open the pump lid before conducting the pressure test, the blue o-ring will probably fall out. If this happens, you will need to install it on the lid again before conducting pressure testing.

3.3.1.2 replace Blue o-ring

1. Turn the lid with locking ring upside down and place it on a stable surface.

2. Place the blue o-ring on the step located ¼" from the bottom of the lid. See Figure 4.

3. Make sure that the o-ring is properly seated. It helps to “place” the o-ring on the step rather than to “roll” it on. That prevents it from rolling off.

There is a risk of damage to the blue o-ring during reinstallation. If you damage it when trying to re-install it, you will need to order a new blue pressure test o-ring

(R0479000) before you begin conducting the pressure test.

These instructions describe the proper procedures for replacing, using, and disposing of the blue o-ring.

These instructions must be followed exactly. Read through the instructions completely before starting the procedure.

notE The blue o-ring sits approximately ¼" away from the seal. See Figure 4.

4. Carefully install the lid, making sure that the blue pressure test o-ring sits in the housing without

“binding” or “rolling” off.

5. Following the markings on the locking ring, align ‘START’ markings with the ports and turn clockwise until ‘LOCKED’ markings align with the ports. Do not tighten past the ‘LOCKED’ marking.

Page 12

ENGLISH

Upside Down View of

Bottom of Lid

Groove where

Seal is Seated

Step where

O-ring is Seated

Figure 4. Placement of Blue Pressure test o-ring

3.3.2 Conduct Pressure test

Warning

When pressure testing a system with water, air is often trapped in the system during the filling process.

This air will compress when the system is pressurized. Should the system fail, this trapped air can propel debris at a high speed and cause injury. Every effort to remove trapped air must be taken, including opening the bleed valve on the filter and loosening the pump basket lid while filling the pump.

Warning

Trapped air in system can cause filter lid to be blown off, which can result in death, serious personal injury, or property damage. Be sure all air is properly out of system before operating. DO NOT USE COM-

PRESSED AIR TO PRESSURE TEST OR CHECK

FOR LEAKS.

Warning

When pressure testing the system with water, it is very important to make sure that the pump basket lid is completely secure.

Warning

Do not pressure test above 35 PSI. Pressure testing must be done by a trained pool professional.

Circulation equipment that is not tested properly can fail, which could result in severe injury or property damage.

1. Fill the system with water, using care to eliminate trapped air.

2. Pressurize the system with water to no more than 35 PSI.

3. Close the valve to trap pressurized water in the system.

Jandy ® Pro Series Stealth ™ Pumps | Operation Manual

4. Observe the system for leaks and/or pressure decay.

5. If there are lid leaks, repeat steps 1-3. For technical support, call 800.822.7933.

6. Discard the blue pressure test o-ring after successfully completing the test.

Section 4. operation

4.1 Start-up

Caution

Never run the pump without water. Running the pump

“dry” for any length of time can cause severe damage to both the pump and motor and will void the warranty.

If this is a new pool installation, make sure all piping is clear of construction debris and has been properly pressure tested. The filter should be checked for proper installation, verifying all connections and clamps are secure according to the manufacturer's recommendations.

Warning

To avoid risk of damage or injury, verify that all power is turned off before starting this procedure.

1. Release all pressure from the system and open the filter pressure release valve.

2. If the pump is located below the water level of the pool, opening the filter pressure release valve will prime the pump with water.

3. If the pump is located above the water level of the pool, remove the lid and fill the basket with water before starting the pump.

4. Prior to replacing the lid, check for debris around the lid o-ring seat. Debris around the lid o-ring seat will cause air to leak into the system, and make it difficult to prime the pump.

5. Hand-tighten the lid to make an air tight seal. Do not use any tools to tighten the lid, hand-tighten only. Make sure all valves are open and the unions are tight.

6. Turn on the power to the pump. Then turn on the pump.

7. Once all the air has left the filter, close the pressure release valve.

8. The pump should prime. The time it takes to prime will depend on the elevation and length of pipe used on the suction supply pipe. See Section

3.1.3.3 for proper elevation and pipe size.

9.

Jandy ® Pro Series Stealth ™ Pumps | Operation Manual

If the pump does not prime and all the instructions to this point have been followed, check for a suction leak and then repeat Steps 2 through 7.

ENGLISH

Page 13

10. Turn on the power to the pump. Once all the air has been evacuated from the filter, close the pressure release valve.

Section 5. Service and

Maintenance

5.1 routine Maintenance

Inspect the pump basket for debris by looking through the clear pump lid. Remove any debris, because as debris accumulates, it will begin to block the flow of water through the pump. Keep the basket clean to improve the performance of the pump.

5.2 Winterizing the Pump

Caution

The pump must be protected when freezing temperatures are expected. Allowing the pump to freeze will cause severe damage and void the warranty.

Caution

Do not use antifreeze solutions in the pool, spa,

or hot tub systems! Antifreeze is highly toxic and may damage the circulation system. The only exception to this is Propylene Glycol. For more information see your local pool/spa supply store or contact a qualified swimming pool service company.

1. Turn off the power to the pump. If the pump is located below the water level, close the isolation valves on the suction and discharge sides of the pump to prevent a backflow of water.

2. Turn the lid's locking ring counter-clockwise until 'START' aligns with the ports. (You may use a tool for leverage to open the lid, but never

to tighten the lid when closing it.) Carefully remove the lid.

Caution

A misaligned basket will cause the lid to be improperly seated, allowing an air leak which could result in pump damage.

1. Drain all water from the pump, system equipment, and piping.

2. Remove the two drain plugs. Store the drain plugs in a safe location and reinstall them when the cold weather season is over. Do not lose the

o-rings. (Drain Plug with O-ring Set, R0446000)

3. Keep the motor covered and dry.

3. Lift the basket out of the pump.

4. Dispose of the debris and thoroughly clean the basket, making sure all the holes are open. Using a garden hose, spray the basket from the outside to help clear the holes. Use your hands to remove any remaining debris.

5. Replace the basket in the pump by aligning the opening with the suction pipe. If aligned properly, the basket will drop easily into place.

Do not force into place.

6. Prior to replacing the lid, check for debris around the lid o-ring seat, as this will cause air to leak into the system. Clean the lid o-ring and place it on the lid.

7. Hand-tighten the lid to make an air tight seal. Do not use any tools to tighten the lid: hand-tighten only.

8. Verify that all valves have been returned to the proper position for normal operation.

9. Open the pressure release valve on the filter, and make sure it is clean and ready for operation. notE Covering the pump with plastic will create condensation, and this moisture will damage the pump. The best way to protect your pump is to have a qualified service technician or electrician properly disconnect the electrical wiring at the switch or junction box. Once the power is removed, the two unions can be loosened and the pump stored indoors. For safety, and to prevent entry of contaminants, reinstall all conduit and terminal box covers.

4. When the system is reopened for operation, make sure all piping, valves, wiring, and equipment are in accordance with the manufacturer's recommendations. Pay close attention to the filter and electrical connections.

5. The pump must be primed prior to starting; refer to Section 4.1, Start-up.

Page 14

ENGLISH Jandy ® Pro Series Stealth ™ Pumps | Operation Manual

Section 6. troubleshooting and repair

Zodiac Pool Systems, Inc. strongly recommends that you call a qualified service technician to perform any repairs on the filter/pump system. To locate an independent service company, check your local yellow pages or visit www.jandy.

com and click on "Product Support."

6.1 troubleshooting

Symptom Possible Problem/Solution

The cleaning/circulating system is not operating correctly.

Bubbles present in the pump basket.

Air leaks are still present.

There is no air in the system, but the pressure is still low.

There is no debris blocking the impeller and the pressure is still low.

The pump is leaking water between the motor and pump body.

The pump gets hot and shuts off periodically.

Verify that skimmer baskets, pump basket and other screens are clean. Clean as necessary.

Check filter and clean as necessary.

Check valve positions. Adjust as necessary.

notE Multiple pieces of equipment operating at one time (for example, waterfalls, spa jets, and surface returns) may prevent the cleaning system from working properly.

Check the cleaning system manually to ensure that the system is adjusted according to the manufacturer's recommendations.

Air in system. Check the pool or spa water level to ensure it is at the proper level and that air is not being drawn into the suction piping. If the water is at normal level, turn off the pump. Remove the lid and check for debris around the lid o-ring seat or improper installation of the lid seal, as this either of these conditions will cause air to leak into the system. Clean the lid o-ring and place on the lid. Hand-tighten the lid to make an air tight seal. Do not use any tools to tighten the lid. Turn the pump back on.

Check the suction side piping union. While the pump is running, try to tighten the union. If this does not stop the air leak, turn off the pump. Loosen both unions and slide the pump out of the way. Remove, clean and re-install both union o-rings.

Reposition the pump next to the piping and secure the union nuts to the pump. With clean union o-rings, hand-tightening of the unions should create a seal. If the unions still do not seal, gently tighten with a large pair of tongue-and-groove pliers.

Do not over-tighten.

It is possible that debris is caught in the pump impeller. The pump impeller moves the water, and the vanes in the impeller can become blocked with debris. See

Section 6.2, Service Technician Maintenance, 6.2.1, Blocked Impeller, for more information.

The pump impeller and diffuser are showing signs of normal wear. Have a qualified service technician check the impeller and diffuser and replace as necessary.

If the pump is part of a relatively new installation, it could be an electrical problem.

Contact a qualified service technician. Have the technician check for loose electrical connections and check the voltage at the pump motor while it is in operation. The voltage must be within 10% of the motor's data plate rating. If the voltage is not within 10%, contact a qualified electrician and/or the local power service provider.

Pump seal is leaking air. Have a qualified service technician replace the seal.

This is caused by a damaged or failed mechanical seal. Replace the seal. See

Section 6.2, Service Technician Maintenance, 6.2.4, Mechanical Seal Replacement.

Ensure that there is adequate room around the motor to circulate air and keep the motor cool. Have a qualified electrician check for loose connections and check the voltage at the pump motor while it is in operation. The voltage must be within 10% of the motor's data plate rating. If the voltage is not within 10%, contact a qualified electrician and/or the local power service provider.

Jandy ® Pro Series Stealth ™ Pumps | Operation Manual

6.2 Service technician Maintenance

Warning

This pump must be serviced by a professional service technician, qualified in pool/spa installation. The following procedures must be followed exactly. Improper installation and/or operation can create dangerous electrical hazards, which can cause high voltages to run through the electrical system, possibly causing property damage, serious injury, or death. Improper installation and/or operation will void the warranty.

ENGLISH

Page 15

2. Turn off any valves to prevent pool water from

Reaching the pump. Drain the water from the pump by loosening the unions or removing the drain plugs.

3. Using a 9/16" wrench, loosen the bolts connecting the pump body to the motor backplate. See Figure 5.

Bolts (8)

6.2.1 Blocked impeller

Warning

While servicing the pump, switch off the circuit breakers at the power source. Severe personal injury or death may occur if the pump starts while your hand is inside the pump.

Pump

Body

Motor Backplate

1. Turn off the pump. Switch off the circuit breaker to the pump motor.

2. Remove the lid and basket.

3. Look inside the pump for any debris. Remove any debris found inside.

4. Replace the basket and lid.

5. Switch on the circuit breaker to the pump motor.

6. Turn on the pump, and see if the problem is solved.

7. If the impeller is still blocked with debris and it is not possible to remove the debris using steps 2 through 4, the pump will need to be disassembled in order to access the inlet and outlet of the impeller.

Motor Shaft Cover

Figure 5. remove the Pump Housing

4. Pull the motor and backplate out of the pump body. Remove the pump body o-ring. The impeller is connected to the motor shaft.

5. Using a No. 1 Phillips screwdriver, remove the two (2) screws holding the diffuser. (The diffuser is the cover over the impeller.) Then remove the diffuser, see Figure 6. The SHPF 5.0 uses a different diffuser than other models. See Figure 8.

notE At this point you have access to the inlet and outlet of the impeller to remove any debris.

Backplate

6.2.2 impeller removal

Warning

While servicing the pump, switch off the circuit breakers at the power source. Severe personal injury or death may occur if the pump starts while your hand is inside the pump.

1. Turn off the pump. Switch off the circuit breaker to the pump motor. If you are not replacing the motor, do not disconnect the electrical wiring.

Motor diffuser

Screws with Washers

(2) notE If you are replacing the motor, Zodiac Pool Systems,

Inc., strongly recommends that a qualified service technician or electrician properly disconnect the electrical wiring at the pump motor.

Motor diffuser o-ring

Figure 6. remove the diffuser

Page 16

ENGLISH Jandy ® Pro Series Stealth ™ Pumps | Operation Manual

Pump Body diffuser o-ring diffuser diffuser o-ring diffuser Screws with Washers (2)

Self Sealing left

Handed Screw

Backplate o-ring diffuser impeller o-ring location for SHP only o-ring location for PHP/MHP only

Figure 7. location of the diffuser o-ring diffuser

Pump Body diffuser o-ring

Mechanical

Seal

Backplate

Figure 10. diffuser and impeller Exploded View

6. Remove the motor shaft cover on the back of the motor by twisting the hex-head screw with a 90° crescent wrench, see Figure 5. The motor shaft will be exposed.

7. Hold the exposed motor shaft with a ½" wrench while removing the impeller center screw using a

No. 3 Phillips screwdriver. See Figure 9. notE The impeller center screw is a left-hand threaded screw. Therefore, turn the screw clockwise to loosen.

8. Hold the motor shaft with a ½" wrench while unscrewing the impeller from the motor shaft with your hand. notE The impeller is a right-handed thread, therefore turn the impeller counter-clockwise to unscrew.

9. Inspect the impeller and diffuser for signs of rubbing and/or damage.

Figure 8. location of the diffuser o-ring on a SHPF

5.0 HP only

Self Sealing left

Handed Screw

6.2.3 impeller replacement

1. Press the new carbon face seal half, see Figure

11 on the motor shaft using a twisting motion.

Make sure the carbon surface is facing toward the ceramic ring in the backplate.

Caution

VErY iMPortant! Grasp the lower portion of the seal (opposite the carbon face) when installing the seal, or it will be damaged.

Backplate impeller

Mechanical Seal

Figure 9. remove the impeller notE To assist assembly, only use water and soap solution as a lubricant. Any other lubricant will destroy the seal after a short period of time. notE Exercise great care to keep the seal and mating parts clean.

2.

Jandy ® Pro Series Stealth ™ Pumps | Operation Manual

While holding the motor shaft with a ½" wrench, thread the impeller onto the motor shaft. Handtighten the impeller until it is secure. Install the impeller center screw into the center of the impeller and tighten, using a No. 3 Phillips screwdriver. Do not overtighten. notE The impeller center screw is a left-hand threaded screw. Therefore, turn the screw counter-clockwise to tighten.

3. Replace the motor shaft cover by inserting the cover tabs into the slots and rotating the cover

90º clockwise.

4. Replace the diffuser over the impeller, using care to insert alignment pins into the correct holes.

The molded-in arrow must point toward the handle of the backplate.

5. Replace the two (2) small Phillips head screws.

Tighten the screws to draw the diffuser against the motor backplate. For 5.0HP, SWF models only, use additional lock washers. See Figure 12.

6. Make sure the diffuser o-ring, o-ring groove, and o-ring seal area are clean and free of debris, which could cause a leak. If you removed the diffuser o-ring, install it into the groove you removed it from, see Figures 7 and 8. If grease is used to retain the o-ring, it must be silicone based. Do not use petroleum-based grease. It will destroy the o-ring.

7. Slide the diffuser into the mating hole in the pump body. While supporting the motor, start two (2)screws on opposite sides. This will hold the motor in position while you start the other six

(6) screws.

8. Tighten the screws lightly in a crossing “X” pattern using a 9/16" wrench, starting with the inner (middle) four (4) then the outer (top and bottom) four (4) to draw the backplate to the body in an even manner. Once all the screws are snug, torque in the same order to 18 foot-pounds.

Carbon Seal Surface

ENGLISH

9. If the pump is located above water level of the pool, remove the lid and fill the basket with water before starting the pump.

notE Prior to replacing the lid, check for debris around the lid o-ring seat, as this will cause air leaks into the system.

10. Hand-tighten the lid to make an air tight seal. Do not use any tools to tighten the lid.

11. Open the pressure release valve on the filter, and make sure it is clean and ready for operation.

12. Switch on the circuit breaker to the pump motor.

13. Turn on the pump and check the system for normal operation.

14. Once all the air has left the filter, close the pressure release valve.

6.2.4 Mechanical Seal replacement notE This is a two part replacement process. The mechanical seal must be replaced as a set.

notE Refer to Figure 12 for an illustration of the location of the mechanical seal and impeller.

Warning

Page 17

Do not damage the ceramic or carbon surfaces of the seals. If surfaces are damaged, leaks will occur.

1.

3.

To access the mechanical seal, follow steps 1 through 8 of Section 6.2.2, Impeller Removal.

2. Remove the carbon face seal half, see Figure

11 from the motor shaft. This is a spring-loaded seal. Grasp the portion of the seal closest to the impeller body and pull the seal off using a twisting motion.

Remove the motor from the backplate following the steps in Section 6.2.5, Motor Replacement.

Backplate Self Sealing Left

Handed Screw

Impeller

Diffuser

Screws and

Washers (2)

• Ceramic Face Seal

• Backplate Seal

• Carbon Face/ Spring

Side of Seal

• Impeller Side of the

Mechanical Seal

Figure 11. replace the Mechanical Seal

Mechanical Seal

Lock Washers (2)

For 5.0HP SHP &

SWF Models Only

Diffuser O-ring

Figure 12. Backplate, impeller, diffuser, and

Mechanical Seal Exploded View

Page 18

ENGLISH Jandy ® Pro Series Stealth ™ Pumps | Operation Manual

4. Place the backplate o-ring side down and force the ceramic seal out using a screwdriver or drift.

5. Turn the backplate o-ring side up and insert the new ceramic seal side into the backplate. Use great care to press the seal in squarely with your fingers. The ceramic is easily damaged and must be pressed in using only your fingers or soft tools. Do not use any lubricant other than water and soap solution.

6. Install the motor following the steps in

Section 6.2.5, Motor Replacement.

7. Install the backplate following the steps in

Section 6.2.3, Impeller Replacement.

6.2.5 Motor replacement

Caution

To ensure continued safety and reliable operation,

Zodiac Pool Systems, Inc. requires that you replace the motor with a motor that has the identical HP rating and service factor (Zodiac Pool Systems, Inc. approved only).

Warning

To avoid the risk of property damage, severe personal injury, or death, turn off the pump and switch off the circuit breaker to the pump motor before beginning this procedure.

3. Place the backplate motor assembly o-ring side down and unscrew the four (4) 9/16" screws and remove the motor. notE Before removing the backplate, note the alignment of the backplate to the motor. See Figure 13.

4. If installing a new motor, remove the protective plastic cap from the motor shaft. Place the motor on the backplate so that the opening in the motor faces the bottom of the backplate. The starting capacitor on the motor should be at the

12 o'clock position.

5. Replace the four (4) bolts and washers holding the backplate to the motor.

6. To reassemble the pump after replacing the motor, follow steps 1 through 14 of Section 6.2.3,

Impeller Replacement.

7. Have a qualified service technician or electrician properly connect the electrical wiring at the pump motor.

notE Zodiac Pool Systems, Inc. recommends that the mechanical seals be replaced at the same time the motor is replaced. See Section 6.2.4, Mechanical Seal

Replacement, for details.

1. Have a qualified service technician or electrician properly disconnect the electrical wiring at the pump motor.

2. To disassemble the pump housing from the motor, follow steps 1 through 8 in Section 6.2.2,

Impeller Removal.

Backplate

Bolts and

Washers (4)

Starting

Capacitor

Motor

Figure 13. Backplate assembly

Jandy ® Pro Series Stealth ™ Pumps | Operation Manual ENGLISH

Section 7. Product Specifications and Technical Data

Page 19

7.1 replacement Parts list

To order or purchase parts for Zodiac

[email protected].

® pumps, contact your nearest Zodiac dealer. If they cannot supply you with what you need, contact Zodiac technical support at 800.822.7933 or send an e-mail message to:

Key no.

1

3

3

3

3

3

3

3

3

3

3

3

3

3

1

1

2

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1 description

Single-speed Motor & Hardware, SHPF

Single-speed Motor & Hardware, SHPF

Single-speed Motor & Hardware, SHPF

Single-speed Motor & Hardware, SHPF

Single-speed Motor & Hardware, SHPF

Single-speed Motor & Hardware, SHPF

Single-speed Motor & Hardware, SHPF

Single-speed Motor & Hardware, SHPM

Single-speed Motor & Hardware, SHPM

Single-speed Motor & Hardware, SHPM

Single-speed Motor & Hardware, SHPM

Single-speed Motor & Hardware, SHPM

Two-speed Motor & Hardware, SHPM

Two-speed Motor & Hardware, SHPM

Two-speed Motor & Hardware, SHPM

Single-speed Motor & Hardware, SHPF, 3 Phase

Single-speed Motor & Hardware, SHPF, 3 Phase

Single-speed Motor & Hardware, SHPF, 3 Phase

Single-speed Motor & Hardware, SHPF, 3 Phase

Two-speed Motor & Hardware, SHPF

Two-speed Motor & Hardware, SHPF

Two-speed Motor & Hardware, SHPF

Backplate Kit w/Hardware, O-ring & Mech Seals, SHPF/SHPM

Backplate Kit w/Hardware, O-ring & Mech Seals, SHPF

Impeller & Diffuser w/Screw & O-ring, SHPF

Impeller & Diffuser w/Screw & O-ring, SHPF

Impeller & Diffuser w/Screw & O-ring, SHPF

Impeller & Diffuser w/Screw & O-ring, SHPF

Impeller & Diffuser w/Screw & O-ring, SHPF

Impeller & Diffuser w/Screw & O-ring, SHPF

Impeller & Diffuser w/Screw & O-ring, SHPF

Impeller & Diffuser w/Screw & O-ring, SHPM

Impeller & Diffuser w/Screw & O-ring, SHPM

Impeller & Diffuser w/Screw & O-ring, SHPM

Impeller & Diffuser w/Screw & O-ring, SHPM

Impeller & Diffuser w/Screw & O-ring, SHPM

Screw w/O-ring, Self-sealing order Part no.

R0445114

R0445101

R0445102

R0445103

R0445104

R0445105

R0490200

R0479301

R0479302

R0479303

R0479304

R0479305

R0479307

R0479308

R0479309

R0479101

R0479102

R0479103

R0479104

R0445113

R0445106

R0445107

R0445200

R0445201

R0445301

R0445302

R0445303

R0445304

R0445305

R0445306

R0445307

R0445301

R0445302

R0445303

R0445304

R0445305

R0445302-06

Model no.

(HP)

.50

.50

.75

1.0, 1.0-2

1.5, 1.5-2

2.0, 2.0-2

3.0

5.0

0.75

1.0

1.5

2.0, 2.0-2

2.5, 2.5-2

All

2.5

1.0

1.5

2.0

3.0

1.0

1.5

2.0

.50-3.0

5.0

3.0

5.0

.75

1.0

.75

1.0

1.5

2.0

1.5

2.0

2.5

1.5

2.0

Page 20

ENGLISH Jandy ® Pro Series Stealth ™ Pumps | Operation Manual

15

16

16

17

10

11

12

12

13

14

18

19

7

8

9

5

6

Key no.

4

4 description

Diffuser w/O-ring & Hardware

Diffuser w/O-ring & Hardware

Mechanical Shaft Seal (1 Set) (Carbon and Ceramic)

Body, Pump, SHPF/SHPM

Motor Mounting Foot Assembly w/Screws, SHPF/SHPM

Lid w/ Locking Ring & Seal

Blue Pressure Test O-ring

Pump Debris Filter Basket

Drain Plug w/O-ring (Set of 2)

Tail Piece (2" by 2½"), O-ring & Coupling Nut (Set of 2)

Tail Piece (2½" by 3") with O-ring and Coupling Nut (Set of 2)

Lid Seal and Lid O-ring (Lid O-ring Not Shown)

O-ring, Backplate

O-ring, Tail Piece (Set of 2)

Hardware, Diffuser/Impeller

Hardware, Diffuser/Impeller

Backplate Bolts and Washers (Set of 8)

Motor Bolts and Washers (Set of 4)

Screws, Motor Mounting Foot

Model no.

(HP)

.50-3.0

5.0

All

All

.50-2.5

3.0-5.0

All

All

All

.50-3.0

5.0

All

All

All

All

All

All

All

All order Part no.

R0445400

R0445401

R0479400

R0445601

R0445700

R0445800

R0479000

R0445900

R0446000

R0446101

R0446102

R0446200

R0446300

R0446400

R0446500

R0446501

R0446600

R0446700

R0446800

8

13

9

10

7.2 Exploded View

11 (qty 2)

15

12

4 (qty 2),

16 (qty 2)

4 (qty 2),

16 (qty 2)

3, 16

15

12

6

4 (qty 2),

16 (qty 2)

3, 4

3

2, 5

2

2 (qty 8),

17 (qty 8)

1 (qty 4),

18 (qty 4)

1

2, 14

7 (qty 2),

19 (qty 2)

7

Figure 14. SHPF and SHPM Exploded View

Jandy ® Pro Series Stealth ™ Pumps | Operation Manual

7.3 SHPF and SHPM Pump Curves

ENGLISH

Page 21

Jandy Stealth ™ Series High Head Pumps

Full-Rated (SHPF) and Max-Rated (SHPM)

120

110

50

45

100

90

40

80

SHPF 5.0

35

70

30

60

50

40 SHPF 2.0/

SHPM 2.5

Low Speed

SHPF .50/

SHPM .75

SHPF 2.0/

SHPF 2.0-3PH/

SHPM 2.5

SHPF 3.0/

SHPF 3.0-3PH

25

20

15

30

20

10

0

SHPF 1.0/

SHPF 1.0-3PH/

SHPM 1.5

SHPF 1.5/

SHPF 1.5-3PH/

SHPM 2.0

10

SHPF 1.5/

SHPM 2.0

Low Speed

SHPF .75/

SHPM 1.0

5

SHPF 1.0/

Low Speed

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250

0

Flow Rate, Gallons Per Minute (GPM)

Page 22

ENGLISH Jandy ® Pro Series Stealth ™ Pumps | Operation Manual

7.4 Physical and Operational Specifications

7.4.1 SHPF Pump Specifications

Model no.

SHPF .50

SHPF .75

SHPF 1.0

SHPF 1.5

SHPF 2.0

SHPF 3.0

SHPF 1.0-2SPD

SHPF 1.5-2SPD

SHPF 2.0-2SPD

SHPF 1.0-3PH

SHPF 1.5-3PH

SHPF 2.0-3PH

SHPF 3.0-3PH

SHPF 5.0

2.0

2.5

1.0

1.5

2.0

3.0

5.0

1.5

2.0

3.0

1.0

HP

.50

.75

1.0

Voltage amps

208-230/115 4.4-4.5/8.8

208-230/115 6.0-5.6/11.2

208-230/115 7.8-7.4/14.8

208-230

208-230

208-230

230

9.6-8.8

11.0-10.0

15.0-13.6

7.2/3.0

230

230

10.0/3.5

11.0/4.0

208-230/460 5.0-4.6/2.3

208-230/460 6.4-5.8/2.9

208-230/460 7.1-6.8/3.4

208-230/460 9.0-8.6/4.3

230 19.4

Pipe Size

2-2½"

2-2½"

2-2½"

2-2½"

2-2½"

2½-3"

2-2½"

2-2½"

2-2½"

2-2½"

2-2½"

2-2½"

2½-3"

4"

Carton Weight overall length 'a'

30 lbs.

43 lbs.

31 1 /

8

31 7 /

8

"

"

45 lbs.

32¼"

50 lbs.

57 lbs.

63 lbs.

52 lbs.

57 lbs.

64 lbs.

55 lbs.

57 lbs.

64 lbs.

62 lbs.

68 lbs.

32 5 /

8

"

33 1 /

8

"

33 1 /

8

"

33 1 /

8

"

33 5 /

8

"

33 1 /

8

"

31 7 /

8

"

32 1 /

8

"

32 5 /

8

"

32 5 /

8

"

33¾"

7.4.2 SHPM Pump Specifications

Model no.

SHPM .75

SHPM 1.0

SHPM 1.5

SHPM 2.0

SHPM 2.5

SHPM 1.5-2SPD

SHPM 2.0-2SPD

SHPM 2.5-2SPD

HP

.75

1.0

1.5

2.0

2.5

1.5

2.0

2.5

Voltage amps

208-230/115 4.4-4.5/8.8

208-230/115 6.0-5.6/11.2

208-230/115 7.8-7.4/14.8

208-230

208-230

9.6-8.8

11.0-10.0

230

230

230

7.2/3.0

10.0/3.5

11.0/4.0

Pipe Size Carton Weight overall length 'a'

2-2½" 30 lbs.

31 1 /

8

"

2-2½"

2-2½"

43 lbs.

45 lbs.

31 7 /

8

32¼"

"

2-2½"

2-2½"

2-2½"

2-2½"

2-2½"

50 lbs.

57 lbs.

52 lbs.

57 lbs.

64 lbs.

32 5 /

8

"

33 1 /

8

"

32 1 /

8

"

32 5 /

8

"

33 1 /

8

"

7.4.3 Pump dimensions

Jandy ® Pro Series Stealth ™ Pumps | Operation Manual

'a'

11 3 /

8

" 16 1 /

8

"

ENGLISH

Page 23

10 3 /

8

"

15¼"

10 3 /

8

"

9"

Bolt Holes,

Center to Center

14¾"

Front Edge of union to Center of Bolt Holes notE When installing pump, leave a minimum of two feet (2 ft) of clearance above the pump for removal of strainer basket.

7.5 SHP replacement Motor guide

SHPF Pumps

Pump Model

SHPF .50

SHPF .75

SHPF 1.0

SHPF 1.5

SHPF 2.0

SHPF 3.0

a.o Smith /

Century

B845

B661, B2661

B841, B2841

B842, B2842

B843, B2843

B844, B2844

SHPF 1.0-3PH H635

SHPF 1.5-3PH H636

SHPF 2.0-3PH H637

SHPF 3.0-3PH H755

SHPF 1.0-2SPD B982, B2982

SHPF 1.5-2SPD B983, B2983

SHPF 2.0-2SPD B984, B2984

SHPF 5.0

B1000

SHPM Pumps

Pump Model

SHPM 1.0

SHPM 1.5

SHPM 2.0

SHPM 2.5

a.o Smith/

Century

B863SE

B864SE

B865SE

B866SE

SHPM 1.5 2SPD B982, B2982

SHPM 2.0 2SPD B983, B2983

SHPM 2.5 2SPD B984, B2984

CONFORMS TO UL 1081

CERTIFIED TO CSA C22.2 NO 108

Zodiac Pool Systems, Inc.

2620 Commerce Way, Vista, CA 92081

1.800.822.7933 | www.ZodiacPoolSystems.com

ZODIAC ® is a registered trademark of Zodiac International, S.A.S.U., used under license.

All trademarks referenced herein are the property of their respective owners.

©2012 Zodiac Pool Systems, Inc. H0573800 Rev J 1204

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement