C ROSS T ECHNOLOGIES, INC.
DATA SHEET
REV_B 07/14/14
2082-14X-47 Redundant Unit Controller, 47 Volts Switch Drive
The Model 2082-14X-47 Redundant Unit Controller is used to power, monitor and control LNA or LNB amplifiers configured in 1:1
(2082-141-47) or 1:2 (2082-142-47) redundancy. Front panel LEDs indicate power, status (online, standby, alarm), and mode (auto, manual, local, remote). Up to 600 ma is available to power each amplifier and +47 VDC is provided for 1:1 (3A) or 1:2 (3A) waveguide switch drive. The Model 2082-14X-47 has +47 volts common and the 2082-14X-47P has ground common. LNA or LNB
current is measured and a fault is signaled if the current deviates from user selected thresholds. Multi-function switches select
Auto, Local, or Remote operation, priorities for 1:2, and the signal path in the Manual mode. Remote operation via the RS232/RS485
M&C interface allows selection of priorities (1:2) and the signal path. Ethernet is available as option, -W8, -W18, or -W28. Contact closure to ground inputs allow selection of Local/Remote, and Auto/Manual Modes. An LCD display shows each amplifier ʼ s current, and signal path. Form C relay contact closures indicate amplifier and power supply status, waveguide switch position, Auto, Remote, and Manual operation. Connectors are DB37 for contact closure I/Os, MS3112E16-23S for the amplifier plate signals, and DB9s for monitor and control and auxiliary external contact closure alarm inputs. The 2082-14X-47 is housed in a 1RU chassis and is powered by redundant power supplies fed by separate, fused 100-240 ±10% VAC AC input connectors.
MODE
POWER
ALARM
STDBY
ONLINE
STATUS
AUTO
MANUAL
LOCAL
REMOTE
STATUS
PATH
UNIT 1 UNIT 2 UNIT 3
450
1>1
470
2>2
380
MENU
EXECUTE
MODEL 2082
CONTROLLER
C
ROSS
T
ECHNOLOGIES INC.
1 2 1 2 3
AC1 AC2 PLATE ASSY
GND
I/O
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2
37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20
1
J1 J2
5 4
9
3
8 7
2
6
1
5 4
9 8
3 2
7 6
1
MONITOR
AND
CONTROL
J3A
FUSE
UNIT 1
EXT
ALARM
J3B
VDC
FUSE
UNIT 2
VDC
FUSE
UNIT 3
VDC
F1 DS1 F2 DS2 F3 DS3 J4
GND
Front and Rear Panels (2082-142-47 shown with optional Ethernet)
EQUIPMENT SPECIFICATIONS*
LNA/LNB Power
Output Voltage/current +15 ± 1 Volts/ 0.6 amps max, each unit
Number powered
Switch Drive Characteristics
2 ( for -141), 3 (for -142)
Fault detection time
Total Switchover time
Drive Voltage
Alarm and Control, M&C
Alarm output signal
M & C Interface
50 ms max
100 ms max, based on switch specifications
3A ( for either -141-47 or -142-47)
Form C relay: 100 VDC, 0.5A, 3W max
RS232C or RS485, selectable, Ethernet Optional
9600 baud rate, no parity, 8 data bits, 1 start bit M & C Signal
Controls, Indicators
Mode Select
Power On Status
Remote Select Status
Manual Select Status
Remote M&C Ethernet Options
W8 - Ethernet w/web browser Interface
W18 - Ethernet w/SNMP (and MIB) Interface
W28 - Ethernet w/direct TCP/IP Interface
Other Options
Input Closure alarm option - Call Cross
Local/Remote, Auto/Manual - push-button switches, contact closures, or remote selection
Green LEDs, (PS1, PS2), External Form C contact closure, M&C serial
Yellow LED, External Form C contact closure, M&C serial
Yellow LED, External Form C contact closure, M&C serial
Red LEDs , External Form C contact closure, M&C serial (for amplifiers, Ext. and Summary alarm) Alarm Status
Connectors, Other
Parallel I/O Connector
Ext. Alarm
M&C Connector
Amp Plate Connector
DB37, female
DB9 (female)
DB9 (female)
MS3112E16-23S
Size
Power
1 RU, 19 inch standard chassis 1.75” high X 16.0” deep
Redundant 100 - 240 ±10% VAC, 47 - 63 Hz, 150 W max. power supplies
Models
2082-141-47
2082-142-47
2082-141-47P
1:1 Redundant Unit Controller, +47 VDC common
1:2 Redundant Unit Controller, +47 VDC common
1:1 Redundant Unit Controller, ground common
2082-142-47P 1:2 Redundant Unit Controller, ground common
*10˚C to 40˚C; Specifications subject to change without notice
Cross Technologies, Inc. • www.crosstechnologies.com
6170 Shiloh Road • Alpharetta, GA 30005 • 770.886.8005 • FAX 770.886.7964