2082-14X-47 Redundant Unit Controller, 47 Volts Switch Drive

The Model 2082-14X-47 Redundant Unit Controller is used to power, monitor and control LNA or LNB amplifiers configured in 1:1

(2082-141-47) or 1:2 (2082-142-47) redundancy. Front panel LEDs indicate power, status (online, standby, alarm), and mode (auto, manual, local, remote). Up to 600 ma is available to power each amplifier and +47 VDC is provided for 1:1 (3A) or 1:2 (3A) waveguide switch drive. The Model 2082-14X-47 has +47 volts common and the 2082-14X-47P has ground common. LNA or LNB

current is measured and a fault is signaled if the current deviates from user selected thresholds. Multi-function switches select

Auto, Local, or Remote operation, priorities for 1:2, and the signal path in the Manual mode. Remote operation via the RS232/RS485

M&C interface allows selection of priorities (1:2) and the signal path. Ethernet is available as option, -W8, -W18, or -W28. Contact closure to ground inputs allow selection of Local/Remote, and Auto/Manual Modes. An LCD display shows each amplifier ʼ s current, and signal path. Form C relay contact closures indicate amplifier and power supply status, waveguide switch position, Auto, Remote, and Manual operation. Connectors are DB37 for contact closure I/Os, MS3112E16-23S for the amplifier plate signals, and DB9s for monitor and control and auxiliary external contact closure alarm inputs. The 2082-14X-47 is housed in a 1RU chassis and is powered by redundant power supplies fed by separate, fused 100-240 ±10% VAC AC input connectors.

MODE

POWER

ALARM

STDBY

ONLINE

STATUS

AUTO

MANUAL

LOCAL

REMOTE

STATUS

PATH

UNIT 1 UNIT 2 UNIT 3

450

1>1

470

2>2

380

MENU

EXECUTE

MODEL 2082

CONTROLLER

C

ROSS

T

ECHNOLOGIES INC.

1 2 1 2 3

AC1 AC2 PLATE ASSY

GND

I/O

19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2

37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20

1

J1 J2

5 4

9

3

8 7

2

6

1

5 4

9 8

3 2

7 6

1

MONITOR

AND

CONTROL

J3A

FUSE

UNIT 1

EXT

ALARM

J3B

VDC

FUSE

UNIT 2

VDC

FUSE

UNIT 3

VDC

F1 DS1 F2 DS2 F3 DS3 J4

GND

Front and Rear Panels (2082-142-47 shown with optional Ethernet)

EQUIPMENT SPECIFICATIONS*

LNA/LNB Power

Output Voltage/current +15 ± 1 Volts/ 0.6 amps max, each unit

Number powered

Switch Drive Characteristics

2 ( for -141), 3 (for -142)

Fault detection time

Total Switchover time

Drive Voltage

Alarm and Control, M&C

Alarm output signal

M & C Interface

50 ms max

100 ms max, based on switch specifications

3A ( for either -141-47 or -142-47)

Form C relay: 100 VDC, 0.5A, 3W max

RS232C or RS485, selectable, Ethernet Optional

9600 baud rate, no parity, 8 data bits, 1 start bit M & C Signal

Controls, Indicators

Mode Select

Power On Status

Remote Select Status

Manual Select Status

Remote M&C Ethernet Options

W8 - Ethernet w/web browser Interface

W18 - Ethernet w/SNMP (and MIB) Interface

W28 - Ethernet w/direct TCP/IP Interface

Other Options

Input Closure alarm option - Call Cross

Local/Remote, Auto/Manual - push-button switches, contact closures, or remote selection

Green LEDs, (PS1, PS2), External Form C contact closure, M&C serial

Yellow LED, External Form C contact closure, M&C serial

Yellow LED, External Form C contact closure, M&C serial

Red LEDs , External Form C contact closure, M&C serial (for amplifiers, Ext. and Summary alarm) Alarm Status

Connectors, Other

Parallel I/O Connector

Ext. Alarm

M&C Connector

Amp Plate Connector

DB37, female

DB9 (female)

DB9 (female)

MS3112E16-23S

Size

Power

1 RU, 19 inch standard chassis 1.75” high X 16.0” deep

Redundant 100 - 240 ±10% VAC, 47 - 63 Hz, 150 W max. power supplies

Models

2082-141-47

2082-142-47

2082-141-47P

1:1 Redundant Unit Controller, +47 VDC common

1:2 Redundant Unit Controller, +47 VDC common

1:1 Redundant Unit Controller, ground common

2082-142-47P 1:2 Redundant Unit Controller, ground common

*10˚C to 40˚C; Specifications subject to change without notice

Cross Technologies, Inc. • www.crosstechnologies.com

6170 Shiloh Road • Alpharetta, GA 30005 • 770.886.8005 • FAX 770.886.7964

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Frequently Answers and Questions

What is the purpose of the Cross Technologies 2082-141-47?
It is a 1:1 Redundant Unit Controller used to power, monitor, and control amplifiers configured in redundancy.
What are the input power requirements?
Redundant 100 - 240 ±10% VAC, 47 - 63 Hz, 150 W max. power supplies.
What type of connectors does it have?
DB37 for contact closure I/Os, MS3112E16-23S for amplifier plate signals, and DB9s for monitor and control and auxiliary external contact closure alarm inputs.
How many amplifiers can it power?
It can power up to 2 amplifiers.
What is the output voltage and current?
It provides +15 ± 1 Volts/ 0.6 amps max, for each unit.
What are the available options for this device?
Ethernet with a web browser interface (W8), Ethernet with SNMP (and MIB) interface (W18), Ethernet with direct TCP/IP interface (W28), and Input Closure alarm option.