advertisement
▼
Scroll to page 2
of 19
EverPlex 8 C Q USER'S MANUAL EverPlex 8 C Q A B + NEXT. Real Time Color Quad Processor High Resolution, Broadcast Quality Playback Zoom Function RS232 Remote Control Connect Up To 8 Cameras Set Seq DEFAULT Table of Content Notice................................................................................................................. 1 Safety Warning................................................................................................... 2 Introduction ....................................................................................................... 3 Specification....................................................................................................... 4 Chapter I Functional Description............................................................... 5 1. Front Panel Kepads ..........................................................................................5 1.1 Full Screen ...................................................................................................5 1.2 Page A/B Switch..........................................................................................5 1.3 Sequential Switch ........................................................................................5 1.4 VCR Play Back............................................................................................5 1.5 Set ........................................................................................................6 1.5.1 Date, Time setting, and OSD display on/off setting ...............................7 1.5.2 Alarm Records .......................................................................................7 1.5.3 Set the Brightness, Contrast, Color, Tinit for each channel in Page A....8 1.5.4 Set the Brightness, Contrast, Color, Tinit for each channel in Page B....8 1.5.5 Set the camera titles for Page A .............................................................8 1.5.6 Set the camera titles for Page B .............................................................9 1.5.7 Set sequential switching parameters.......................................................9 1.5.8 Set alarm parameters ............................................................................10 Chapter II Back Panel Connection............................................................11 1. BNC Connectors ............................................................................................ 11 1.1 Monitor ...................................................................................................... 11 1.2 REC. out .................................................................................................... 11 1.3 Play back.................................................................................................... 11 1.4 Video in...................................................................................................... 11 2. Alarm Connectors (DB-15) ............................................................................ 11 2.1 Alarm out ...................................................................................................12 2.1.1 Normally open connection ...................................................................12 2.1.2 Normally closed connection.................................................................12 2.2 Alarm in and alrm reset..............................................................................13 2.2.1 Alarm in ...............................................................................................13 2.2.2 Alarm reset...........................................................................................14 3. RS232 Connector............................................................................................14 3.1 The pin assignment of the 9 pin D-SUB connector....................................15 3.2 Transmission setting...................................................................................15 3.3 Remote control protocol.............................................................................15 3.4 Alarm message sent via RS232..................................................................16 4. Record output selection....................................................................................16 1 Notice This manual is presented to the users of EverPlex 8CQ by EverFocus Electronics Corp. With years of engineering researches, EverFocus has spared no effort to provide the high quality products to the worldwide users. For the policy of continual product improvement, EverFocus reserves the right to make changes to the product specifications and documentation without notice. All the components of the products, including accessories, components, and outlook, are based on the agreements if each deals to satisfy all kinds of users. Meanwhile, please be advised that every step of operation must follow the instruction of this manual to keep EverPlex 8CQ working under the best condition. Please notice that EverFocus will not be charged any claims or renewing cases resulted from inappropriate operation. EverFocus Electronics Corp. 2 Important Messages: 1. To prevent fire or shock hazard, do not expose this equipment to the environment of high humidity and dust. So, do not use it in an unprotected outdoor installation or any area classified as a wet area. 2. Installation environment: The temperature should be kept between -10oC ~ +50oC, humidity under 90%. 3. For safety sake, do not disseminate the unit or put it on an unstable base. 4. Ventilation: Openings in the enclosure are provided for ventilation and to ensure reliable operation of the unit and to protect it from overheating. These openings must not be blocked or covered. This unit should not be placed in a built-in installation unless proper ventilation is provided. 5. Cleanse: Unplug the unit from the outlet before cleansing. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth to clean it. 6. Overload: Do not overload outlets and extension cords as this may result in a fire or electric shock. 7. Power-cord Protection: Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the appliance. 8. Object and Liquid Entry: Never push objects of any kind into this unit through openings as they may touch dangerous voltage points or short-out parts that could result in a fire or electric shock. Never spill liquid of any kind on the unit. 9. Service: Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous voltage of other hazards. Refer all servicing to qualified service personnel. EverFocus Electronics Corp. 3 Introduction Everplex 8CQ, a two page real time color Quad and 8 channel auto switcher, is the best choice for multiple monitoring and recording. The superior video quality is achieved by adopting the advance multi-media technology. The picture of Quad display is sharp and clear because Everplex 8CQ is featured with CCIR601 full resolution and 16 million colors. Main Features: Real-time Quad display. High Resolution 720 x 576 (PAL), 720 x 480 (NTSC). 16 million colors. Up to 8 camera inputs, two-page quad display. Video loss detection. Different border colors indicate page selection. Independent brightness, contrast, color and tint adjustments for every channel. Built-in timer and and title generator. Alarm input with built-in buzzer. Programmable Quad and 8 channel auto switcher output at the same time. Playback Zoom and Freeze function. RS232 Remote Control. User-friendly front panel design. EverFocus Electronics Corp. 4 Specification Video input: 8 cameras + one VCR inputs Video output: Video output x 2, 1V p-p/75 ohm Title: Up to 6 characters Timer: Built-in real time clock Alarm input: 8 alarm inputs and 1 alarm reset input Alarm output: 2 Alarm Out (1 Normally Open, 1 Normally Closed) Dimension: 239 x 166 x 55 mm Power source: AC 10~24V or DC 12V Power consumption: 17W max. EverFocus Electronics Corp. 5 Chapter I Functional Description 1. Front Panel Keypads EverPlex 8 C Q A B + Set Seq NEXT. DEFAULT 1.1 Full Screen Press any key of FULL SCREEN, the picture of the corresponding quadrant will fill the whole screen of the monitor display. Press the same key again, the quad display will come out. 1.2 Page A/B Switch Press A(B), the live pictures from Page A(B) will be displayed on the main monitor and VCR output for recording. 1.3 Sequential Switching Press SEQ key will enter the auto sequential switching mode, the switching sequence is programmed in SET function, it will display live quad & full screen sequentially on the main monitor according to the programmed switching sequence. Press the SEQ key again, To exit the auto sequential mode and stay the last screen display. 1.4 VCR Play Back Press PLAY BACK key, To play back the recorded video from VCR. There are two special functions implemented in the play back mode. A. ZOOM function Press any FULL SCREEN key during playback, will zoom the picture of the corresponding quadrant to the whole screen of the monitor display. Press the same key again, To stop the zoom function and back to the normal playback video. B FREEZE function Press the SEQ key during zoom mode, To freeze the current frame, press any key again will de-freeze the video and perform the corresponding function for that key. EverFocus Electronics Corp. 6 1.5 Set Press the SET key to set time/date, title on/off, picture, camera titles, switching sequence, switching time period, alarm sensor type, alarm hold time, and display the alarm/video loss records. There are 8 pages in the setting mode : Page 1 : Page Page Page Page Page Page Set Time and Date. Turn ON/OFF the time, date, title display for Quad or Full screen display. Display the alarm records. Set the brightness, contrast, color, and tint for cameras in page A Set the brightness, contrast, color, and tint for cameras in page B Change camera titles of Page A. Change camera titles of Page B. Program the sequential switching sequence and switching hold time. Set the screen refresh mode. Set the alarm sensor type, alarm hold time, buzzer on/off and Security. 2: 3: 4: 5: 6: 7: Page 8: The follow keys are re-defined in setting mode (Definition under the keypad) Press next page to select the page to set. NEXT P. DEFAULT Press the default to set the default setting if they are available. Press the +/- keys to set the value. + Press the cursor key to select the item to set. EverFocus Electronics Corp. 7 1.5.1 Date, Time setting, and OSD display on/off setting DATE: TIME: 1997-01-01 01:01:01 QUAD SCREEN DATE: QUAD SCREEN TIME: QUAD SCREEN TITLE: ON ON ON FULL SCREEN DATE: FULL SCREEN TIME: FULL SCREEN TITLE: ON ON ON VERSION N.NN DATE data format is CCYY-MM-DD, where CC : Century code from 19 to 20 YY : Year data from 00 to 99 MM : Month data from 01 to 12 DD : Day data from 01 to 31 TIME data format is HH-MM-SS, where HH : Hour data from 00 to 23 MM : Minute data from 00 to 59 SS : Second data from 00 to 59 VERSION shows current firmware version 1.5.2 Alarm Records ALARM C A DATE RECORDS TIME 3 S 1997-03-24 10:00:00 The Alarm Record format is : (C A DATE TIME) C : the channel number from 1 to 8 which invokes the alarm A : Alarm type, 'S' - alarm from sensor input, 'V' - alarm from video loss detection DATE, TIME - the date and time when the alarm happens EverFocus Electronics Corp. 8 1.5.3 Set the Brightness, Contrast, Color, Tint for each channel in Page A PAGE A 1.5.4 BRIGHT: 32 CONTRAST:27 COLOR: 31 TINT: 32 BRIGHT: 32 CONTRAST:27 COLOR: 31 TINT: 32 BRIGHT: 32 CONTRAST:27 COLOR: 31 TINT: 32 BRIGHT: 32 CONTRAST:27 COLOR: 31 TINT: 32 Set the Brightness, Contrast, Color, Tint for each channel in Page B PAGE B 1.5.5 BRIGHT: 32 CONTRAST:27 COLOR: 31 TINT: 32 BRIGHT: 32 CONTRAST:27 COLOR: 31 TINT: 32 BRIGHT: 32 CONTRAST:27 COLOR: 31 TINT: 32 BRIGHT: 32 CONTRAST:27 COLOR: 31 TINT: 32 Set the camera titles for Page A CH1: CH1 CH2: CH3: CH4: EverFocus Electronics Corp. CH2 CH3 CH4 9 1.5.6 Set the camera titles for Page B CH5: CH5 CH6: CH7: CH6 CH7 CH8: 1.5.7 CH8 Set sequential switching parameters SEQUENTIAL CH1: CH2: CH3: CH4: QUAD A: OFF OFF OFF OFF ON SWITCH TIME SWITCH CH5: CH6: CH7: CH8: QUAD B: : REFRESH MODE : MENU OFF OFF OFF OFF ON 03 SEC FIELD CH1 - CH8 to turn each channel ON or OFF in the sequential switching QUAD A, B to turn each QUAD ON or OFF in the sequential switching SWITCH TIME : The time period to switch for each switching item REFRESH MODE : to set the screen refresh by 'FRAME' or by 'FIELD' EverFocus Electronics Corp. 10 1.5.8 Set alarm parameters ALARM SETTING MENU CH 1 2 3 4 SENSOR N.O. N.O. N.O. N.O. CH 5 6 7 8 SENSOR N.O. N.O. N.O. N.O. ALARM RESET IN : BUZZER : KEY LOCK : ALARM HOLD TIME: N.O. ON OFF 05 SEC CH1 - CH8 to set the sensor input type as 'N.O.' : normally open, closed will invoke alarm 'N.C.' : normally closed, open will invoke alarm 'closed' means to short the alarm signal line to the ground ALARM RESET IN : to set alarm reset input type as 'N.O.' or 'N.C.' BUZZER : turn the buzzer ON/OFF KEY LOCK : turn the KEY LOCK function ON or OFF, when key lock is turned on 1. all keys except SET key are locked 2. KEY LOCK stays ON until we turn it OFF by pressing the SET key ALARM HOLD TIME : the time period to buzz (if buzzer is on) and send alarm out signal when an alarm in EverFocus Electronics Corp. 11 Chapter II Back Panel Connection VIDEO INPUT PAGE A 10~24 VAC PAGE B PLAY BACK REC. OUT MONITOR ALARM I/O DC12V 1. BNC Connectors 1.1 MONITOR Connect this output port to the main monitor. 1.2 REC. OUT Connect this output port to the VIDEO IN of VCR. The quad video output of current active page is obtained from this connector. 1.3 PLAY BACK Connect this input port to the VIDEO OUT of VCR. 1.4 VIDEO IN Connect camera video out to this connector by a 75 ohm coaxial cable. 8 1 2. Alarm Connectors (DB-15) 15 PIN # 1 2 3 4 5 6 7 8 NAME Alarm Out Common contact Alarm Out Normally Closed Alarm Reset GROUND ALARM IN 4 ALARM IN 3 ALARM IN 2 ALARM IN 1 EverFocus Electronics Corp. PIN # 9 10 11 12 13 14 15 9 NAME Alarm Out Normally Open TXD * RXD * ALARM IN 8 ALARM IN 7 ALARM IN 6 ALARM IN 5 12 2.1 Alarm out There are two ways to do the alarm out connection: 2.1.1 Normally Open Connection (use pin # 1 and # 9) 2 8 1 RELAY 15 COIL Alarm out 9 EverPlex 8CQ 2.1.2 Normally Closed Connection (use pin # 1 and # 2) 2 8 1 15 9 EverPlex 8CQ EverFocus Electronics Corp. COIL Alarm out RELAY 13 2.2 Alarm in and Alarm reset There are 8 alarm sensors in for 8 channels and 1 alarm reset in, all these 9 alarm input can be set to Normally Open or Normally Closed by user and the setting menu. ALARM CIRCUIT SENSOR 1 SENSOR 2 SENSOR 3 SENSOR 4 2 8 SENSOR 5 SENSOR 6 SENSOR 7 SENSOR 8 15 ALARM RESET 1 9 EverPlex 8CQ 2.2.1 ALARM IN There are eight alarm inputs, one for each camera of page A & B. Please connect the alarm input in the same sequence as the cameras input BNC of page A & B. When any alarm signal is input, machine will do the following: 1. switch to the full screen display of this channel. 2. blink the channel ID with alarm message. 3. turn on the buzzer if the buzzer setting is on. When more alarms come up in the alarming status, the monitor screen will switch to quad display to show all the channels which have alarms in. EverFocus Electronics Corp. 14 The ALARM IN can be selected as normally open input or normally closed input: Normally Open : if the alarm input is selected as Normally Open input, then the (N.O.) input is opened normally, and shorted to the ground means an alarm happens Normally Closed : if the alarm input is selected as Normally Closed input, then the (N.C.) input is shorted to the ground normally, and opened means an alarm happens 2.2.2 ALARM RESET External alarm reset signal used to reset the alarm and turn the buzzer off. if it is selected as Normally Closed input, then the input is shorted to the ground normally, and opened when an alarm reset signal comes in. if it is selected as Normally Open input, then the input is opened normally, and shorted to the ground means an alarm reset signal comes in. 3. RS232 Connection EverPlex 8CQ may be controlled by a computer or a terminal via the standard 9 pin D- sub/RS232 connector, which is connected to the alarm I/O by a cable with 15 pin and 9 pin connectors. EverPlex 8CQ will send the alarm message to the host via RS232 when any alarm occurs. VIDEO INPUT PAGE A 10~24 VAC PAGE B PLAY BACK REC. OUT MONITOR ALARM I/O 15-PIN MALE CONNECTOR 5 1 9-PIN D-SUB CONNECTOR 9 EverFocus Electronics Corp. 6 DC12V 15 3.1. The pin assignment of the 9 pin D-SUB connector EverPlex 8CQ PIN # 1 2 3 4 5 6 7 8 9 NAME NOT CONNECTED TXD RXD NOT CONNECTED GROUND NOT CONNECTED NOT CONNECTED NOT CONNECTED NOT CONNECTED HOST PIN # 1 2 3 4 5 6 7 8 9 NAME NOT CONNECTED RXD TXD DTR GROUND DSR RTS CTS NOT CONNECTED 3.2. Transmission Setting The transmission setting in EverPlex 8CQ is 9600 baud rate, 1 start bit, 1 stop bit and no parity 3.3. Remote control protocol A computer or a terminal can be used to control the EverPlex 8CQ by sending two-character ASCII command through RS232 connector, these ASCII commands are started with 'K' or 'k'. there are 9 ASCII commands mapped to the 9 keypads in the front panel and 1 additional commands to reset the EverPlex 8CQ to the QUAD A display state. these 10 ASCII commands are: EverPlex 8CQ Remote Control Command Table ASCII CODE FUNCTION Keypad in front panel K1 Full Screen 1 K2 Full Screen 2 K3 Full Screen 3 K4 Full Screen 4 K5 PAGE A A K6 K7 PAGE B Sequential Switching K8 K9 K0 VCR Play Back SET SET Reset EverPlex 8CQ to Quad display none EverFocus Electronics Corp. B SEQ 16 3.4. Alarm message sent via RS232 EverPlex 8CQ will send out alarm message thru RS232 when any alarm occurs, the alarm message format are three ASCII characters followed carriage return and line feed, they are first charater is the leading code , '!' second character is the alarm type, 'S' indicates a sensor alarm, 'V' indicates a video loss third character is the channel number having the alarm, '1' ~ '8' fouth byte is the carriage return code, 0DH fifth byte is the line feed code, 0AH 4. Record output selection The record out will output quad display according to the page selection. The relation between the outputs of record out and monitor out are: Monitor out Channel 1 Full Screen Channel 2 Full Screen Channel 3 Full Screen Channel 4 Full Screen Page A Quad Screen Channel 5 Full Screen Channel 6 Full Screen Channel 7 Full Screen Channel 8 Full Screen Page B Quad Screen Record out Page A Quad Screen Page A Quad Screen Page A Quad Screen Page A Quad Screen Page A Quad Screen Page B Quad Screen Page B Quad Screen Page B Quad Screen Page B Quad Screen Page B Quad Screen NOTE: To record all 8 cameras into VCR thru record out, turn on Quad A and Quad B simultaneously in sequential switching mode. EverFocus Electronics Corp. EverFocus Electronics Corp. 8F-4, No.79 Sec. 1 Shin-Tai Wu Road, Hsi-Chi, Taipei Hsien, Taiwan TEL : 886-2-26982334 FAX : 886-2-26982380 Suite 102, 2975 Huntington Drive San Marino, CA. 91108 U.S.A. TEL : (626) 844-8888 FAX : (626) 844-8838 Toll free : 1-(888) 383-6287 or 1-(888) EV-FOCUS P/N : MMEPG0010B
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement