Generator_Instruction_Manual • December 5, 2013

Contents

INTRODUCTION ............................................................ 3

SAFETY RULES .............................................................. 3

ADDING OR DRAINING FUEL ....................................... 4

SECTION 2 - GENERAL INFORMATION ...................... 5

2.1 - UNPACKING .......................................................... 5

2.1.1 PACKING CONTENTS ........................................... 5

2.2 - ASSEMBLY ............................................................ 5

2.2.1 - ASSEMBLING THE ACCESSORY KIT ................. 5

SECTION 3 - FEATURES AND CONTROLS .................. 6

Parts of Generators ...................................................... 6

SECTION 4 - PREPARATION BEFORE

OPERATION ................................................................................ 6

4.1 - ADDING ENGINE OIL .......................................... 6

4.2 - ADDING FUEL ....................................................... 7

4.3 - GROUNDING THE GENERATOR ........................... 7

WATTAGE REFERENCE GUIDE ..................................... 8

SECTION 5 — OPERATION ........................................... 8

5.1 STARTING THE ENGINE .......................................... 8

5.2 - CONNECTING ELECTRICAL LOADS ................... 10

5.3 - STOPPING THE ENGINE .................................... 10

5.4 - LOW OIL LEVEL SHUTDOWN SYSTEM ............. 10

5.5 - HIGH ALTITUDE .................................................. 10

SECTION 6 - MAINTENANCE ...................................... 11

6.1 - MAINTENANCE SCHEDULE ............................... 11

6.2 - GENERAL RECOMMENDATIONS ....................... 11

6.2.1 - GENERATOR MAINTENANCE .......................... 11

6.2.2 - TO CLEAN THE GENERATOR .......................... 11

6.2.3 ENGINE MAINTENANCE ................................... 12

6.2.4 CHANGE OIL ..................................................... 12

6.2.5 REPLACE THE SPARK PLUG ............................... 12

6.2.6 SPARK ARRESTOR ............................................. 12

6.3 SERVICE AIR FILTER ............................................. 12

6.4 - VALVE CLEARANCE ............................................. 13

6.5 - GENERAL ............................................................ 13

SECTION 7 - STORAGE .............................................. 13

SECTION 8 - WARRANTY ............................................ 14

SECTION 9 - TROUBLESHOOTING ............................ 15

Page | 2

INTRODUCTION

Thank you for purchasing products by our company, we appreciate your business. The generator is a compact, high performance, air-cooled, engine driven generator designed to supply electrical power to operate electrical loads on job sites, or remote locations where utility power is available or in place of a utility due to a power outage.

This manual contains safety information to make you aware of hazards and risks associated with our generator products and how to avoid them. It is important that you read and understand these instructions thoroughly before attempting to start or operate this equipment.

Save this original instruction manual for future reference.

If any portion of this manual is not understood, contact the nearest authorized dealer for starting, operating and servicing procedures. We also strongly recommend instructing other users to properly start and operate the unit. This prepares them if they need to operate the equipment in an emergency.

The Emission Control System for this generator is warranted for standards set by the Environmental Protection Agency and also the California Air Resources Board.

Every effort has been made to ensure that information in this manual is both accurate and current. However our company reserves the right to change, alter or otherwise improve the generator and this documentation at any time.

DANGER - indicates a hazard which, if not avoided, will result in death or serious injury.

WARNING - indicates a hazard which, if not avoided, could result in death or serious injury.

CAUTION - indicates a hazard which, if not avoided, could result in minor or moderate injury.

NOTICE - address practices not related to personal injury.

WARNING - Running gasoline engines gives off carbon monoxide, an odorless, colorless, poisonous gas.

Breathing carbon monoxide could result in death, serious injury, headache, fatigue, dizziness, vomiting, confusion, seizures, nausea or fainting.

• Operate this product ONLY outdoors.

• Install a battery operated carbon monoxide alarm near any closeto any nearby bedrooms.

• Keep exhaust gas away from entering a confined area through windows, doors, ventilation intakes, or other openings.

• NEVER operate this product inside any building, carport, porch, mobile equipment, marine applications, or enclosure, even if windows and doors are open.

SAFETY RULES

Read this manual carefully and become familiar with your generator. Know its applications, its limitations and any hazards involved.

Throughout this publication, and on tags and decals affixed to the generator, DANGER, WARNING, CAUTION and NOTICE blocks are used to alert personnel to special instructions about a particular operation that may be hazardous if performed incorrectly or carelessly. Observe them carefully. Their definitions are as follows:

WARNING - The engine exhaust from this product, certain components in this product and related accessories, contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. Wash hands after handling.

Page | 3

WARNING - This generator does not meet U.S. Coast

Guard Regulation 33CFR-183 and should not be used in marine applications. Failure to use the appropriate U.S.

Coast Guard approved generator could result in death or serious injury and/or property damage.

• DO NOT stop engine by moving choke control to

“OFF” position.

WHEN TRANSPORTING, OR REPAIRING EQUIPMENT

WARNING - Starter cord kickback (a rapid retraction) will pull hand and arm toward engine faster than you can let go which could cause broken bones, fractures, bruises, or sprains resulting in serious injury.

• Transport/move/repair with fuel tank EMPTY and with the fuel valve OFF.

• DO NOT tip engine or equipment at angle which cause fuel to spill.

• Disconnect spark plug wire.

• When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.

• NEVER start or stop engine with electrical devices plugged in and turned on.

WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN

TANK

WARNING - Fuel and its vapors are extremely flammable and explosive which could cause burns, fire or explosion resulting in death, serious injury and/or property damage.

• Store away from furnaces, stoves, water heaters, clothes dryers, or other appliances that have light or other ignition source because they could ignite fuel vapors.

WARNING - Generator voltage could cause electrical shock or burn resulting in death or serious injury.

ADDING OR DRAINING FUEL

• Turn generator engine OFF and let it cool at least

2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

• Fill or drain fuel tank outdoors only.

• DO NOT overfill tank. Allow space for fuel expansion.

• If fuel spills, wait until it evaporates before starting engine.

• Keep fuel away from sparks, open flames, pilot lights, heat, and any other ignition sources.

• Check fuel lines, tank, cap and fittings frequently for cracks or leaks. Replace if necessary.

• DO NOT light a cigarette or smoke.

WHEN STARTING EQUIPMENT

• Ensure spark plug, muffler, fuel cap, and air cleaner are in place.

• DO NOT crank engine with spark plug removed.

WHEN OPERATING EQUIPMENT

• DO NOT operate this product inside any building, carport, porch, mobile equipment, marine applications, or enclosure.

• DO NOT tip engine or equipment at an angle which could cause fuel to spill.

Page | 4

• Use approved transfer equipment to prevent back feed by isolating generator from electric utility workers.

• When using generator for backup power, notify utility company.

• Use a ground fault circuit interrupter in any damp or highly conductive area, such as metal decking or steel work.

• DO NOT touch bare wires or receptacles.

• DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

• DO NOT operate generator in the rain or wet weather.

• DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

• DO NOT allow unqualified persons or children to operate or service generator.

WARNING - Exhaust heat/gases could ignite combustibles, structures or damage fuel tank causing a fire, resulting in death, serious injury and/or property damage.

Contact with muffler area could cause burns resulting in serious injury.

• DO NOT touch hot parts and AVOID hot exhaust gases.

• Allow equipment to cool before touching.

• Keep at least 5 feet (1.5 m) of clearance on all sides of generator including overhead.

• Replacement parts must be the same and installed in the same position as the original parts.

CAUTION - Excessively high operating speeds could result in minor injury and/or generator damage. Excessively low speeds impose a heavy load.

• DO NOT tamper with governor spring, links or other parts to increase engine speeds. Generator supplies correct rated frequency and voltage when running at governed speed.

• DO NOT modify generator in any way.

NOTICE - Exceeding generators wattage/ amperage capacity could damage generator and/or electrical devices connected to it.

• DO NOT exceed the generator’s wattage/ amperage capacity. See Don’t Overload Generator in the

Operation section.

• Start generator and let engine stabilize before connecting electrical loads.

• Turn electrical loads OFF and disconnect from generator before stopping generator.

NOTICE - Improper treatment of generator could damage it and shorten its life.

• Use generator only for intended uses.

• If you have questions about intended use, ask dealer or contact local service center.

• Operate generator only on level surfaces.

• DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapor.

• DO NOT insert any object through cooling slots.

• If connected devices overheat turn them off and disconnect them from generator.

• Turn off generator if:

- electrical output is lost.

- equipment sparks, smokes, or emits flames.

- or unit vibrates excessively.

SECTION 2 - GENERAL INFORMATION

2.1 - UNPACKING

• Set the carton on a rigid flat surface.

• Remove everything from carton except generator.

• Open carton completely by cutting each corner from top to bottom.

• Leave generator on carton to install wheel kit.

2.1.1 PACKING CONTENTS

• Owner’s Manual

• Wheels

• Wheel Axle

• Plugs

• Hardware Bag - (including 1-Spark Plug Socket;

1-Extension handle )

2.2 - ASSEMBLY

The generator requires some assembly prior to using it.

2.2.1 - ASSEMBLING THE ACCESSORY KIT

The wheels are designed to fit on the unit to greatly improve the portability of the generator.

NOTE - The wheels are Not intended for over-the-road use.

Page | 5

• Refer to Figures to install wheels as shown.

• Slide the axle through the frame brackets.

• Slide on the wheel and flat washer, then assemble flange nuts.

• Refer to Figure to install the bracket as shown.

• Insert an M8 bolt through the bracket. Secure the bolt with an M8 flange nut.

• Insert an M8 bolt through the bracket. Secure the bolt with an M8 flange nut.

SECTION 3 - FEATURES AND CONTROLS

Read this Operator’s Manual and safety rules before operating your generator. Compare the illustrations with your generator to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference.

7 - BATTERY

8 - 120/240 VOLT AC,

30 Amp TWIST LOCK

RECEPTACLE

9 - GROUND TERMI-

NAL

16 - CARBON CANISTER

17 - FUEL TANK CAP

18 - FUEL GAUGE

Parts of Generators

1- CHOKE LEVER 10 - 120 VOLT AC, 30

Amp TWIST LOCK

RECEPTACLE

2 - AIR CLEANER 11 - VOLTMETER

3 - RECOIL STARTER 12 - AC CIRCUIT

BREAKER

4 - ENGINE SWITCH 13 - 120V, 20Amp GFCI

DUPLEX RECEPTACLE

5 - OIL DRAIN BOLT 14 - ROLL OVER VALVE

6 - OIL DIPSTICK 15 - WHEEL

NOTICE - Pictures and drawings used in this manual are for reference only and do not represent any specific model.

SECTION 4 - PREPARATION BEFORE

OPERATION

4.1 - ADDING ENGINE OIL

All oil should meet minimum American Petroleum Institute (API) Service Class SJ, SL or better. Use no special additives. Select the oil’s Viscosity grade according to the expected operating temperature.

• Above 40°F, use SAE 30

• Below 40°F and down to 10°F, use 10W-30

• Below 1°F, use synthetic 5W-30

NOTICE - Improper treatment of generator could damage it and shorten its life. DO NOT attempt to crank or start the engine before it has been properly serviced with the recommended oil. This could result in an engine failure.

Page | 6

• Place generator on a flat, level surface.

• Clean area around oil fill and remove oil fill cap and dipstick. Wipe dipstick clean.

• Slowly fill engine with oil through the oil fill opening until it reaches the full mark on the dipstick.

• Stop filling occasionally to check oil level. Be careful do not over fill. Do not fill to the top of the tank.

• Install oil fill cap and finger tighten securely.

• Check engine oil level before starting each time thereafter.

SION. If fuel spills, wait until it evaporates before starting engine. Check fuel lines, tank, cap and fittings frequently for cracks or leaks. Replace if necessary.

IMPORTANT - It is important to prevent gum deposits from forming in fuel system parts such as the carburetor, fuel hose or tank during storage. Alcohol-blended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic gas can damage the fuel system and should be emptied before storage of 30 days or longer. See the “Storage” section. Never use engine or carburetor cleaner products in the fuel tank as permanent damage may occur.

4.2 - ADDING FUEL

DANGER - Never fill tank indoors. Never fill fuel tank when engine is running or hot. Turn generator engine

OFF and allow engine to cool entirely before filling fuel tank. Avoid spilling gasoline on HOT engine. Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources. DO NOT light a cigarette or smoke when filling the fuel tank. Fuel is highly FLAM-

MABLE and its vapors are EXPLOSIVE.

• Use regular UNLEADED gasoline with the generator engine. Do not use any fuel with more than 10% added ethanol, and never use E85 fuel.

• Do not mix oil with gasoline.

• Install fuel cap and wipe up any spilled gasoline.

4.3 - GROUNDING THE GENERATOR

The national Electrical Code requires that the frame and external electrically conductive part of this generator be properly connected to an approved earth ground.

Local electrical codes may also require proper grounding of the unit. For that purpose, connecting a No. 10

AWG (American Wire Gauge) stranded copper wire to the grounding lug and to an earth-driven copper or brass grounding rod (electrode) provides adequate protection against electrical shock. However, local codes may vary widely. Consult with a local electrician for grounding requirement in the area.

Proper grounding of the generator will help prevent electrical shock in the event of ground fault condition in the generator or in connected electrical devices. Proper grounding also helps dissipate static electricity, which often builds up in ungrounded devices.

CAUTION - Do not overfill the fuel tank. Allow space for fuel expansion. IF the fuel tank is overfilled, fuel can overflow onto a HOT engine and cause FIRE or EXPLO-

Page | 7

WATTAGE REFERENCE GUIDE

Tool or Appliance Running*

(Rated)

Watts

Essentials

75 Light Bulb - 75 watt

Furnace Fan

Blower - 1/2 HP

Sump Pump -1/3

HP

Refrigerator/

Freezer

Water Well Pump -

1/2 HP

800

800

700

1000

Heating/Cooling

Window AC

-10,000 BTU

Humidifier - 13 Ga

Central AC -

24,000 BTU

1200

175

3800

Kitchen

1000 Microwave Oven -

1000 Watt

Coffee Maker

Electric Stove - 8”

Element

Toaster

Family Room

DVD/CD Player

VCR

Stereo Receiver

Color Television -

27 in

Personal Computer w/17 in monitor

1000

2100

850

800

100

100

450

500

Other

Security System

AM/FM Clock

Radio

500

100

Additional Starting (Surge) Watts

2350

1300

2200

2100

3600

11400

Page | 8

Garage Door

Opener - 1/2 HP

Electric Water

Heater

Job Site

Quartz Halogen

Work Light

Airless Sprayer -

1/3 HP

Reciprocating Saw

Electric Drill - 1/2

HP, 5.4

Circular Saw -

7-1/4 in

Miter Saw - 10 in

Table Planer - 6 in

Table Saw/Radial

Arm Saw

Air Compressor -1

HP

875

4700

1000

600

960

600

1400

1800

1800

2000

1600

2350

11700

SECTION 5 — OPERATION

5.1 STARTING THE ENGINE

WARNING - Never start or stop engine with electrical devices plugged into the receptacles and devices turned on.

1200

900

2300

1800

1800

2000

4500

Unplug all electrical loads from the unit’s receptacles before starting the engine. Make sure the unit is in a level position. then fully into ON position.

NOTICE - If battery is discharged, use manual starting instructions.

Turn the Fuel Shut-off level Valve to the “On” position.

Move engine choke lever to the ON position.

For Recoil start, firmly grasp the recoil handle and pull slowly until increased resistance is felt. Pull rapidly up and away.

For electric start, turn and hold key in start switch to

“start” position until generator starts. To prolong the life of starter components, DO NOT hold key in “start” position for more than 15 seconds, and pause for at least 1 minute between starting attempts.

When engine starts, move choke lever to 1/2 - CHOKE position until engine runs smoothly then and fully into

ON position. If engine falters, move choke back out to

1/2- CHOKE position until engine runs smoothly and

NOTICE - If engine fires, but does not continue to run, move choke lever to the OFF position and repeat starting instructions.

WARNING - Starter cord kickback (rapid retraction) will pull hand and arm toward engine faster than you can let go which could cause broken bones, fractures, bruises, or sprains resulting in serious injury.

When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.

Never start or stop engine with electrical devices plugged in and turned on.

NOTICE - If engine starts after 3 pulls but fails to run, or if unit shuts down during operation, make sure unit is on a level surface and check for proper oil level in crankcase. This unit may be equipped with a low oil protection device. If so, oil must be at proper level for engine to start.

WARNING - Exhaust heat/ gases could ignite combustible, structures or damage fuel tank causing a fire, resulting in death, serious injury and/or property damage.

Contact with muffler area could cause burn resulting in serious injury.

Page | 9

DO NOT touch hot muffler and AVOID hot exhaust gases. Allow equipment to cool before touching. Keep at least 5 feet (152 cm) of clearance on all sides of generator including overhead. Contact the original equipment manufacturer, retailer, or dealer to obtain a spark arrester designed for the exhaust system installed on this engine. Replacement parts must be the same and installed in the same position as the original parts.

IMPORTANT - Do not overload the generator. Also, do not overload individual panel receptacles. These outlets are protected against overload with push-to-reset-type circuit breakers. If amperage rating of any circuit breaker is exceeded, that breaker opens and electrical output to that receptacle is lost.

5.2 - CONNECTING ELECTRICAL LOADS

• Let engine stablize and warm up for a few minutes after starting.

• Plug in and turn on the desired 120 and/or 240 Volt

AC, single phase, 60 Hz electrical loads.

• Add up the rated watts (or amps) of all loads to be connected at one time. This total should not be greater than, (a) the rated wattage/amperage capacity of the generator or, (b) circuit breaker rating of the receptacle supplying the power.

NOTICE - DO NOT connect 240 Volt loads to the

120 Volt duplex receptacles.

DO NOT connect 3 phase loads to the generator.

DO NOT connect 50 Hz loads to the generator.

NOTICE - Start generator and let engine stabilize before connecting electrical loads. Connect electrical loads such as tools then turn them ON for operation.

Turn electrical loads OFF and disconnect from generator before stopping generator.

NOTICE - Exceeding generators wattage/ amperage capacity could damage generator and/or electrical devices connected to it. DO NOT exceed the generator’s wattage/amperage capacity.

Overloading a generator in excess of its rated wattage capacity can result in damage to the damage to the generator and to connected electrical devices. Observe the following to prevent overloading the unit:

Add up the total wattage of all electrical devices to be connected at one time. This total should NOT be greater than the generator’s wattage capacity.

The rated wattage of lights can be taken from light bulbs. The rated wattage of tools, appliances and motors can usually be found on a data label or decal affixed to the device.

If the appliance, tool or motor does not give wattage, multiply volts times ampere rating to determine watts

(volts × amps = watts).

Some electric motors, such as induction types, require about three times more watts of power for starting than for running. This surge of power lasts only a few seconds when starting such motors. Make sure to allow for high starting wattage when selecting electrical devices to connect to the generator:

Figure the watts needed to start the largest motor.

Add to that figure the running watts of all other connected loads.

The wattage reference guide is provided to assist in determining how many items the generator can operate at one time.

5.3 - STOPPING THE ENGINE

Shut off all loads then unplug the electrical loads from generator panel receptacles. Never start or stop the engine with electrical devices plugged in and turned on.

Let engine run at no-load for several minutes to stabilize the internal temperatures of engine and generator.

Move ON/OFF switch to OFF position. Close fuel valve.

5.4 - LOW OIL LEVEL SHUTDOWN SYSTEM

The engine is equipped with a low oil level sensor that shuts down the engine automatically when the oil level drops below a specified level. If the engine shuts down by itself and the fuel tank has enough gasoline, check engine oil level.

5.5 - HIGH ALTITUDE

At altitudes over 5,000 feet (1524 meters), a minimum

85 octane / 85 (89 RON) gasoline is acceptable. To re-

Page | 10

main emissions compliant, high altitude adjustment is required. Operation without this adjustment will cause decreased performance, increased fuel consumption, and increased emissions. See an authorized dealer for high altitude adjustment information. Operation of the engine at altitudes below 2,500 feet (762 meters) with the high altitude kit is not recommended.

SECTION 6 - MAINTENANCE

6.1 - MAINTENANCE SCHEDULE

Follow the calendar intervals. More frequent service is required when operating in adverse conditions noted below.

Some adjustments will need to be made periodically to properly maintain the generator.

All adjustments in the Maintenance section of this manual should be made at least once each season. Follow the requirements in the “Maintenance Schedule.”

NOTE - Once a year replace the spark plug and replace the air filter. A new spark plug and clean air filter assure proper fuel-air mixture and help the engine run better and last longer.

First 8 Hours

• Change engine oil

Every 8 Hours or Daily

• Clean debris

• Check engine oil level

Every 25 Hours or Every Season

• Clean engine air filter

Every 20 Hours or Every Season

• Change engine oi1

Yearly

• Replace engine air filter

• Service fuel valve

• Service spark plug

• Inspect muffler and spark arrester

• Clean cooling system

Note - Change the oil more often when operating under heavy loads or in high temperatures. Clean the air filter more often under dirty or dusty operating conditions

6.2.1 - GENERATOR MAINTENANCE

Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves, or any other foreign material.

Check the cleanliness of the generator frequently and clean when dust, dirt, oil, moisture or other foreign substances are visible on its exterior surface.

CAUTION - Never insert any object or tool through the air cooling slots, even if the engine is not running.

NOTE - DO NOT use a garden hose to clean generator.

Water can enter the engine fuel system and cause problem. In addition, if water enters the generator though cooling air slots, some water will be retained in voids and crevices of the rotor and stator winding insulation.

Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.

6.2.2 - TO CLEAN THE GENERATOR

6.2 - GENERAL RECOMMENDATIONS

The warranty of the generator does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the generator as instructed in this manual.

• Use a damp cloth to wipe exterior surfaces clean.

• A soft bristle brush may be used to loosen cakedon dirt, oil etc.

• A vacuum cleaner may be used to pick up loose dirt and debris.

• Low pressure air (not to exceed 25 psi) may be used to blow away dirt. Inspect cooling air slots and openings on the generator. These openings must be kept clean and unobstructed.

Page | 11

6.2.3 ENGINE MAINTENANCE

DANGER - When working on the generator, always disconnect spark plug wire from spark plug and keep wire away from spark plug.

6.2.4 CHANGE OIL

Change the oil after the first eight hours of operation, then every 20 hours thereafter. If running this unit under dirty or dusty conditions, or in extremely hot weather, change the oil more often.

• Stop the engine and pull the spark plug wire off of the spark plug.

• Clean the area around the spark plug and remove it from the cylinder head.

• Set the spark plug’s gap to 0.70-0.80 mm (0.028-

0.031 in.). Install the correctly gapped spark plug into

.

the cylinder head and torque to 15 ft/lbs.

CAUTION Hot oil may cause burns. Allow engine to cool before draining oil. Avoid prolonged or repeated skin exposure with used oil. Thoroughly wash exposed areas with soap.

Use the following instructions to change the oil while the engine is still warm:

• Clean area around oil drain plug.

• Remove oil drain plug from engine and oil fill plug to drain oil completely into a suitable container.

• When oil has completely drained, install oil drain plug and tighten securely.

• Fill engine with recommended oil. (See “ADDING

ENGINE OIL” for oil recommendations).

• Wipe up any spilled oil.

• Dispose of used oil at a proper collection center.

6.2.5 REPLACE THE SPARK PLUG

Use spark plug F6RTC. Replace the plug once each year.

This will help the engine start easier and run better.

6.2.6 SPARK ARRESTOR

• Shut off generator and allow the engine and muffler to cool down completely before servicing spark arrestor (located on the back of the muffler).

• Remove the clamp and spark arrestor screen.

• Clean the spark arrestor screen with a small

• wire brush.

• Replace the spark arrestor if it is damaged.

• Installation of the spark arrestor screen is the reverse of the removal.

6.3 SERVICE AIR FILTER

The engine will not run properly and may be damaged if using a dirty air filter. Replace the air filter once a year.

Clean or replace more often if operating under dusty conditions.

• Remove air filter cover.

• Wash in soapy water. Squeeze filter dry in clean cloth (DO NOT TWIST).

• Clean air filter cover before re-installing it.

Page | 12

DANGER - Drain fuel into approved container outdoors, away from open flame. Be sure engine is cool.

Do not smoke.

DANGER - NEVER cover the generator while engine and exhaust area are warm.

SECTION 7 - STORAGE

It is important to prevent gum deposits from forming in essential fuel system parts such as the carburetor, fuel hose or tank during storage. Also, experience indicates that alcohol-blended fuels (called gasohol, ethanol or methanol) can attract moisture, which leads to separation and formation of acids during storage. Acidic gas can damage the fuel system of an engine while in storage.

To avoid engine problems, the fuel system should be emptied before storage of 30 days or longer, as follows:

Remove all gasoline from the fuel tank.

6.4 - VALVE CLEARANCE

After the first 50 hours of operation, check the valve clearance in the engine and adjust if necessary.

Important: If you are not comfortable with this procedure or the proper tools are not available, please take the generator to the nearest service center to have the valve clearance adjusted. This is a very important step to ensure longest life for the engine.

6.5 - GENERAL

The generator should be started at least once every seven days and be allowed to run at least 30 minutes.

If this cannot be done and the unit must be stored for more than 30 days, use the following information as a guide to prepare it for storage.

DANGER - NEVER store engine with fuel in tank indoors or in enclosed, poorly ventilated areas where fumes may reach an open flame, spark or pilot light as on a furnace, water heater, clothes dryer or other gas appliance.

CAUTION - Avoid spray from spark plug holes when cranking engine.

• Start and run engine until engine stops from lack of fuel.

• While engine is still warm, drain oil from crankcase. Refill with recommended grade.

• Remove spark plugs and pour about 1/2 ounce (15 ml) of engine oil in the cylinders. Cover spark plug hole with rag. Pull the recoil starter a couple times to lubricate the piston rings and cylinder bore.

Install and tighten spark plugs. Do not connect spark plug wires.

• Clean the generator outer surfaces. Check that cooling air slots and openings on generator are open and unobstructed.

• Store the unit in clean, dry place.

• Do not store gasoline from one season to another.

Page | 13

• Replace the gasoline can if it has started to rust.

Rust and/or dirt in the gasoline will cause problems with the carburetor and fuel system.

• If possible, store the unit indoors and cover it to give protection from dust and dirt. BE SURE TO

EMPTY THE FUEL TANK.

If it is not practical to empty the fuel tank and the unit is to be stored for some time, use a commercially available fuel stabilizer added to the gasoline to increase the life of the gasoline.

• Cover the unit with a suitable protective cover that does not retain moisture.

SECTION 8 - WARRANTY

We welcome warranty repair and apologize to you for being inconvenienced. Any Authorized Service Dealer may perform warranty repairs. Consumer sales are warranted for one (1) year. Most warranty repairs are handled routinely, but sometimes requests for warranty service may not be appropriate. For example, warranty service would not apply if equipment damage occurred because of misuse, lack of routine maintenance, shipping, handling, warehousing or improper installation.

Similarly, the warranty is void if the manufacturing date or the serial number on the portable generator has been removed or the equipment has been altered or modified. During the warranty period, the Authorized

Service Dealer, at its option, will repair or replace any part that, upon examination, is found to be defective under normal use and service. This warranty will not cover the following repairs and equipment:

• REGULAR WEAR: Outdoor Power Equipment, as with all mechanical devices, need periodic part(s) service and replacement to perform as designed. This warranty will not cover repair when normal use has exhausted the lifetime of a part(s) or engine.

• INSTALLATION AND MAINTENANCE: This warranty does not cover the generator or parts when they have been subjected to improper or unauthorized use, assembly, altered, modified, or damage due to misuse, negligence, accident, overloading, over-speeding, improper maintenance, repair or storage so as, in our judgment, to adversely affect its performance and reliability. This warranty also does not cover regular maintenance and parts such as air filters, adjustments, fuel system cleaning and obstruction (due to chemical, dirt, carbon, lime, and so forth).

• OTHER EXCLUSIONS: This warranty excludes wearing parts such as o-rings, filters, etc., or malfunctions resulting from accidents, abuse, modifications, alterations, or improper servicing or freezing or chemical deterioration; Damaged related to rodent and/or insect infestation. Accessory parts such as starting batteries, generator adapter cord sets and storage covers are excluded from the product warranty. This warranty excludes used, reconditioned, and demonstration equipment, equipment used for prime power in place of utility power, equipment used in life support applications, and failures due to acts of God and other force majeure events beyond the manufacturers control, such as collision, theft, vandalism, riot or wars, nuclear holocaust, fire, freezing, lightning, earthquake, windstorm, hail, volcanic eruption, water or flood, tornado or hurricane.

Page | 14

SECTION 9 - TROUBLESHOOTING

Problem

Engine is running but no AC output is available

Cause

1.One of the circuit breakers is off.

2.Fault in generator.

3.Poor connection or defective cord set.

4.Connected device is bad.

Correction

1.Turn circuit breaker to ON.

2.Contact Authorized Service facility.

3.Check and repair.

4.Connect another device that is in good condition.

Engine runs good but bogs down when loads are connected.

Engine will not starts or runs rough or shuts down when running.

1.Short circuit in a connected load.

2.Engine speed is too slow.

3.Generator is overloaded.

4.Shorted generator circuit.

5.Clogged or dirty fuel filter.

1.Start switch in “Off“ position.

2.Fuel valve is in “Off ” position.

3.Failed battery.

4.Low oil level.

5.Dirty air cleaner.

6.Clogged or dirty fuel filter.

7.Out of fuel.

8.Stale fuel.

9.Spark plug wire not connected to spark plug.

10.Bad spark plug.

11.Water in fuel.

12.Flooded.

13.Excessively rich fuel mixture.

14.Intake valve stuck open or closed.

15.Engine has lost compression.

1.Disconnect shorted electrical load.

2.Contact Authorized Service facility.

3.See Don’t Overload Generator.

4.Contact Authorized Service facility.

5.Clean or replace fuel filter.

1.Turn key in start switch to on.

2.Turn fuel valve to “On” position.

3.Replace battery.

4.Fill crankcase to proper level or place generator on level surface.

5.Clean or replace air cleaner.

6.Clean or replace fuel filter.

7.Fill fuel tank.

8.Drain fuel tank and carburetor;fill with fresh fuel.

9.Connect wire to spark plug.

10.Replace spark plug.

11.Drain fuel tank and carburetor;fill with fresh fuel.

12.Wait 5 minutes and re-crank engine.

13.Contact Authorized Service facility.

14.Contact Authorized Service facility.

15.Contact Authorized Service facility.

Engine lacks power.

Engine”hunts” or falters

1.Load is too high.

2.Dirty air filter.

3.Clogged or dirty fuel filter.

1.See Don’t Overload Generator.

2.Replace air filter.

3.Clean or replace fuel filter.

1.Carburetor is running too rich or too lean.

2.Clogged or dirty fuel filter.

3. Choke is opened too soon.

1.Contact Authorized Service facility.

2.Clean or replace fuel filter.

3.Move choke to halfway position until engine runs smoothly.