Cissell DMP Operating instructions


Add to my manuals
33 Pages

advertisement

Cissell DMP Operating instructions | Manualzz

Drying Tumblers

50 Pound Capacity

75 Pound Capacity

Refer to Page 3 for Model Identification

Keep These Instructions for Future Reference.

(If this machine changes ownership, this manual must accompany machine.) www.comlaundry.com

Part No. 70400301R5

January 2009

Installation must conform with local codes or in the absence of local codes with:

In the U.S.A., installation must conform to the latest edition of the American National Standard Z223.1/

NFPA 54 “National Fuel Gas Code” and Standard ANSI/NFPA 70 “National Electric Code.”

In Canada, installation must comply with Standards CAN/CSA-B149.1 or Natural Gas and Propane Code

CSA C22.1, latest edition, Canadian Electric Code, Part I.

In Australia, installation must comply with the Australian Gas Association Installation Code for Gas

Burning Appliances and Equipment.

WARNING

FOR YOUR SAFETY, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death.

W033

• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

• WHAT TO DO IF YOU SMELL GAS:

– Do not try to light any appliance.

– Do not touch any electrical switch; do not use any phone in your building.

– Clear the room, building or area of all occupants.

– Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

– If you cannot reach your gas supplier, call the fire department.

• Installation and service must be performed by a qualified installer, service agency or the gas supplier.

W052

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

W053

MISE EN GARDE

POUR VOTRE SÉCURITÉ, les informations de ce guide doivent être respectées afin de réduire les risques d’incendie, d’explosion ou d’éviter les dommages matériels, personnels ou blessures mortelles.

W033R3QU

• Ne pas entreposer ou utiliser d’essence ou toutes autres vapeurs et liquides inflammables à proximité de cette machine ou de tout autre appareil.

• QUE FAIRE EN CAS D’ODEUR DE GAZ :

– Ne pas mettre d’appareil en marche.

– Ne pas toucher aux interrupteurs

électriques ; ne pas utiliser le téléphone des lieux.

– Évacuer la pièce, le bâtiment ou la zone de tous les occupants.

– Appeler immédiatement le fournisseur de gaz de la maison d’un voisin.

Respecter les instructions communiquées par le fournisseur.

– Si vous ne pouvez pas joindre le fournisseur de gaz, appeler le service d’incendie.

• L’installation et l’entretien doivent être effectués par un installateur, service d’entretien qualifiés ou par le fournisseur de gaz.

W052R5QU

POUR VOTRE SÉCURITÉ

Ne pas entreposer ou utiliser d’essence ou toutes autres vapeurs et liquides inflammables à proximité de cette unité ou de tout autre appareil.

W053R2QU

IMPORTANT: Information must be obtained from a local gas supplier on instructions to be followed if the user smells gas. These instructions must be posted in a prominent location. Step-by-step instructions of the above safety information must be posted in a prominent location near the tumbler for customer use.

70400301 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 1

Table of

Contents

Introduction.........................................................................................

3

Model Identification .............................................................................

3

Customer Service..................................................................................

4

Serial Plate Location.............................................................................

4

Wiring Diagram ....................................................................................

4

Safety Information..............................................................................

5

Explanation of Safety Messages ...........................................................

5

Important Safety Instructions ...............................................................

6

Operating Instructions .......................................................................

8

Emergency Stop Button on CE Models................................................

8

Operating Instructions ..........................................................................

8

Control Instructions ..............................................................................

9

Electromechanical Coin Control......................................................

9

Manual Timer Control ..................................................................... 10

Dual Digital Timer Control.............................................................. 11

Single Drop Control ......................................................................... 13

DX4 Coin Control............................................................................ 15

DX4 OPL Control ............................................................................ 16

Diagnostic Microprocessor Control ................................................. 17

DMP OPL Models ........................................................................... 18

DMP Coin ........................................................................................ 20

Ignition Control Operation ................................................................... 24

Maintenance ........................................................................................ 26

Daily ..................................................................................................... 26

Monthly................................................................................................. 27

Quarterly ............................................................................................... 27

Bi-Annually .......................................................................................... 27

Annually ............................................................................................... 27

Before You Call for Service ............................................................... 31

Customer Service.................................................................................. 31

© Copyright 2009, Alliance Laundry Systems LLC

All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher.

2 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70400301

Introduction

Model Identification

Information in this manual is applicable to these models:

50 Pound

75 Pound

Gas

CHD50G2-CA050L

CHD50G2-CA050N

CHD50G2-CT050L

CHD50G2-CT050N

CHD50G2-CU050L

CHD50G2-CU050N

DR55G2-BA050L

DR55G2-BA050N

DR55G2-BT050D

DR55G2-BT050L

DR55G2-BT050N

DR55G2-BU050L

DR55G2-BU050N

IPD50G2-IT050L

IPD50G2-IT050N

CHD75G2-CA075L

CHD75G2-CA075N

CHD75G2-CT075L

CHD75G2-CT075N

CHD75G2-CU075L

CHD75G2-CU075N

DR80G2-BA075L

DR80G2-BA075N

DR80G2-BT075D

DR80G2-BT075L

DR80G2-BT075N

DR80G2-BU075L

DR80G2-BU075N

IPD75G2-IT075L

IPD75G2-IT075N

Includes models with control suffixes:

3O – DX4 OPL

3V – DX4 vended

3X – DX4 prep for coin

CD – rotary coin drop

CX – prep for coin

DO – DMP OPL

Steam/Thermal Oil

CHD50S2-CT050S

CHD50S2-CU050S

CT050T

CU050T

DR55S2-BT050S

DR55S2-BT050T

DR55S2-BU050S

DR55S2-BU050T

IPD50S2-IT050S

IPD50S2-IT050T

CHD75S2-CT075S

CHD75S2-CU075S

CT075T

CU075T

DR80S2-BT075S

DR80S2-BT075T

DR80S2-BU075S

DR80S2-BU075T

IPD75S2-IT075S

IPD75S2-IT075T

DV – DMP vended

DX – DMP prep for coin

MT – manual timer

QT – dual digital timer

R3 – reversing DX4 OPL

RD – reversing DMP OPL

Electric

CHD50E2-CT050E

CHD50E2-CU050E

DR55E2-BT050E

DR55E2-BU050E

IPD50E2-IT050E

CHD75E2-CT075E

CHD75E2-CU075E

DR80E2-BT075E

DR80E2-BU075E

IPD75E2-IT075E

RQ – reversing dual digital timer

RT – reversing manual timer

SD – single drop

SX – single drop, prep for coin

70400301 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 3

Introduction

Customer Service

If literature or replacement parts are required, contact the source from which the machine was purchased or contact Alliance Laundry Systems at (920) 748-3950 for the name and address of the nearest authorized parts distributor.

For technical assistance, call (920) 748-3121.

Serial Plate Location

When calling or writing for information about your product, be sure to mention model and serial numbers.

Model and serial numbers are found on serial plate on rear of machine, and inside door hinge. Refer to

Figure 1.

Wiring Diagram

The wiring diagram is located in the junction or contactor box.

Models starting Serial No. 0309___ or later will have the wiring diagram part number in the lower portion of the electrical data on the serial plate.

60

50

40

30

10

20 HE

AT

15

CO

DO

OL

10

TE

PE

HI GH

RA

RE W

LO

PU SH

ST TO

1

1

Serial Plate

Figure 1

TMB803N

TMB803N

4 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70400301

Safety Information

Explanation of Safety Messages

Precautionary statements (“DANGER,” “WARNING,” and “CAUTION”), followed by specific instructions, are found in this manual and on machine decals. These precautions are intended for the personal safety of the operator, user, servicer, and those maintaining the machine.

DANGER

Indicates an imminently hazardous situation that, if not avoided, will cause severe personal injury or death.

IMPORTANT: Warranty is void unless tumbler is installed according to instructions in the

Installation Manual. Compliance with minimum specifications and requirements detailed herein, and with applicable local gas fitting regulations, municipal building codes, water supply regulations, electrical wiring regulations, and any other relevant statutory regulations. Because of varied requirements, applicable local codes should be thoroughly understood and all pre-installation work arranged for accordingly.

WARNING

Indicates a hazardous situation that, if not avoided, could cause severe personal injury or death.

WARNING

Failure to install, maintain, and/or operate this machine according to manufacturer’s instructions may result in conditions which can produce serious injury, death and/or property damage.

W051R1

CAUTION

Indicates a hazardous situation that, if not avoided, may cause minor or moderate personal injury or property damage.

Additional precautionary statements (“IMPORTANT” and “NOTE”) are followed by specific instructions.

IMPORTANT: The word “IMPORTANT” is used to inform the reader of specific procedures where minor machine damage will occur if the procedure is not followed.

NOTE: The word “NOTE” is used to communicate installation, operation, maintenance or servicing information that is important but not hazard related.

NOTE: The WARNING and IMPORTANT instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution and carefulness are factors which CANNOT be built into this tumbler.

These factors MUST BE supplied by the person(s) installing, maintaining or operating the tumbler.

Always contact your dealer, distributor, service agent or the manufacturer on any problems or conditions you do not understand.

70400301 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 5

6

Safety Information

Important Safety Instructions

Save These Instructions

WARNING

Hazardous Voltage. Can cause shock, burn or cause death. Allow machine power to remain off for two minutes prior to working in and around AC inverter drive.

W359

1. Read all instructions before using the tumbler.

2. Refer to the GROUNDING INSTRUCTIONS for the proper grounding of the tumbler.

3. Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry cleaning solvents, other flammable or explosive substances as they give off vapors that could ignite or explode.

4. Do not allow children on or in the tumbler. This appliance is not intended for use by young children or infirm persons without supervision.

Young children should be supervised to ensure that they do not play with the appliance.

5. Before the tumbler is removed from service or discarded, remove the door to the drying compartment and the door to the lint compartment.

6. Do not reach into the tumbler if the cylinder is revolving.

7. Do not install or store the tumbler where it will be exposed to water and/or weather.

8. Do not tamper with the controls.

9. Do not repair or replace any part of the tumbler, or attempt any servicing unless specifically recommended in the user-maintenance instructions or in published user-repair instructions that you understand and have the skills to carry out.

10. Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.

11. To reduce the risk of fire, DO NOT DRY plastics or articles containing foam rubber or similarly textured rubberlike materials.

12. Always clean the lint filter daily.

13. Keep area around the exhaust opening and adjacent surrounding area free from the accumulation of lint, dust and dirt.

14. The interior of the tumbler and the exhaust duct should be cleaned periodically by qualified service personnel.

15. If not installed, operated and maintained in accordance with the manufacturer’s instructions or if there is damage to or mishandling of this product’s components, use of this product could expose you to substances in the fuel or from fuel combustion which can cause death or serious illness and which are known to the State of

California to cause cancer, birth defects or other reproductive harm.

16. Tumbler will not operate with the loading door open. DO NOT bypass the door safety switch to permit the tumbler to operate with the door open.

The tumbler will stop tumbling when the door is opened. Do not use the tumbler if it does not stop tumbling when the door is opened or starts tumbling without pressing or turning the START mechanism. Remove the tumbler from use and call for service.

17. Tumbler will not operate with lint panel open.

DO NOT bypass lint panel safety switch to permit the tumbler to operate with the lint panel open.

18. Do not put articles soiled with vegetable or cooking oil in the tumbler, as these oils may not be removed during washing. Due to the remaining oil, the fabric may catch on fire by itself.

19. To reduce the risk of fire, DO NOT put clothes which have traces of any flammable substances such as machine oil, flammable chemicals, thinner, etc. or anything containing wax or chemicals such as in mops and cleaning cloths, or anything dry-cleaned at home with dry-cleaning solvent in the tumbler.

20. Use the tumbler only for its intended purpose, drying fabrics.

21. ALWAYS disconnect and lockout the electrical power to the tumbler before servicing. Disconnect power by shutting off appropriate breaker or fuse.

22. Install this tumbler according to the

INSTALLATION INSTRUCTIONS. All connections for electrical power, grounding, and gas supply must comply with local codes and be made by licensed personnel when required.

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70400301

23. Remove laundry immediately after tumbler stops.

24. Always read and follow manufacturer’s instructions on packages of laundry and cleaning aids. Heed all warnings or precautions. To reduce the risk of poisoning or chemical burns, keep them out of reach of children at all times

(preferably in a locked cabinet).

25. Do not tumble fiberglass curtains and draperies unless the label says it can be done. If they are dried, wipe out the cylinder with a damp cloth to remove particles of fiberglass.

26. Always follow the fabric care instructions supplied by the garment manufacturer.

27. Never operate the tumbler with any guards and/or panels removed.

28. DO NOT operate the tumbler if it is smoking, grinding, has missing or broken parts.

Safety Information

29. DO NOT bypass any safety devices.

30. Solvent vapors from dry-cleaning machines create acids when drawn through the heater of the drying unit. These acids are corrosive to the tumbler as well as to the laundry load being dried. Be sure make-up air is free of solvent vapors.

31. Failure to install, maintain, and/or operate this machine according to the manufacturer’s instructions may result in conditions which can produce bodily injury and/or property damage.

WARNING

To reduce the risk of serious injury, install lockable door(s) to prevent public access to rear of tumblers.

W055

70400301 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 7

8

Operating Instructions

WARNING

To reduce the risk of fire:

• DO NOT DRY articles containing foam rubber or similarly textured rubberlike materials.

• DO NOT DRY plastics, anything containing wax or chemicals such as mops and cleaning cloths, or anything dry-cleaned at home with a dry-cleaning solvent.

• DO NOT TUMBLE fiberglass curtains and draperies unless the label says it can be done. If they are dried, wipe out the cylinder with a damp cloth to remove particles of fiberglass.

W076

To reduce the risk of serious injury, allow cylinder to stop before cleaning lint screen.

W412

Emergency Stop Button on CE

Models

All CE approved OPL tumblers are factory equipped with an emergency stop button located on the front

panel. Refer to Figure 2.

1

Emergency Stop Button

1

TMB1664N

Figure 2

To operate emergency stop button: a. Press red emergency stop button to stop all action.

b. To restart machine, pull red emergency stop button out and press START pad or button.

NOTE: Activation of the emergency stop button stops all machine control circuit functions, but

DOES NOT remove all electrical power from machine.

Operating Instructions

Step 1: Clean Lint Screen/Compartment

Remove any accumulated lint from the lint screen and compartment. Close panel tightly against tumbler frame and lock panel securely, if applicable.

IMPORTANT: Clean lint screen and lint compartment daily. Failure to clean the lint screen daily will result in higher than normal temperatures that may damage laundry.

Step 2: Load Laundry

Open loading door and load cylinder with laundry. DO

NOT OVERLOAD.

NOTE: Overloading causes slow drying and wrinkling.

Close loading door. Tumbler will not operate with the door open.

Step 3: Determine Control Type and

Temperature Setting

Refer to the various controls, pages 9-23, follow

instructions for the appropriate control type.

The type of fabric being dried will determine the temperature setting. Consult the fabric care label or fabric manufacturer to determine proper temperature setting.

IMPORTANT: Always follow the fabric care instructions supplied by the garment manufacturer.

Step 4: Remove Laundry

When the cycle is complete, open door and remove the laundry.

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70400301

Operating Instructions

Control Instructions

1

SELECT

TEMP

2

INSERT

COIN

3

PUSH

START TEMPERATURE

HIGH LOW

PUSH

TO

START

INSERT QUARTER

TURN KNOB

QU

AR

T

25

ERMAST

E

R

TMB807N

TMB807N

Figure 3

Electromechanical Coin Control

CD and CX Control Suffixes

1. Set the TEMPERATURE selector at HIGH or

LOW, or anywhere between these settings.

2. Coin Drop Models: Insert the coin(s) in the coin slot, turn the knob to the right and release it.

3. Press the PUSH TO START button and hold it for approximately three (3) seconds.

IMPORTANT: If the loading door or lint panel door is opened during the cycle, the heating system will shut off and the motor will stop. However, the timer will continue to run. To restart the cycle, both doors must be closed and the PUSH TO START button must be pressed in.

4. When the cycle is complete, open door and remove the laundry.

70400301 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 9

Operating Instructions

REVERSING MODELS

50

60

40

0

30

10

20

HEAT

15

10

0

TMB804N

5

COOL

DOWN

TEMPERATURE

HIGH

LOW

PUSH

TO

START

NONREVERSING MODELS TMB805N

TMB805N

Manual Timer Control

MT and RT Control Suffixes

1. Set the HEAT/DRYING timer for the number of minutes (from 0-60) desired.

2. Set the COOL DOWN/COOLING timer for the number of minutes (from 0-15) desired.

3. Set the TEMPERATURE selector at HIGH,

LOW or anywhere between these settings.

4. Select reversing or nonreversing cylinder rotation setting, if applicable.

5. Press the PUSH TO START button in and hold it in for approximately three seconds. This starts the tumbler cycle.

Figure 4

IMPORTANT: If the loading door or lint panel door is opened during the cycle, the heating system will shut off and the motor will stop. To restart the cycle, both doors must be closed and the PUSH TO

START button must be pressed in.

6. When the cycle is complete, open door and remove the laundry.

10 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70400301

Operating Instructions

REVERSING MODELS TMB2136N

TMB2136N

NONREVERSING MODELS TMB2133N

Dual Digital Timer Control

QT and RQ Control Suffixes

1. Select HIGH, MED, LOW or NO HEAT by turning the temperature knob.

HIGH temperature 190°F (87°C)

MED temperature 170°F (77°C)

LOW temperature 120°F (49°C)

2. Set the HEAT TIME for the number of minutes

(from 0-60) desired.

3. Set the COOL DOWN TIME for the number of minutes (from 0-15) desired.

4. Select reversing or nonreversing cylinder rotation setting, if applicable.

5. Press and release START button to start tumbler.

Display will show minutes remaining before end of cycle.

NOTE: One touch drying is available for repetitive loads. If the START button is pressed while the machine is in Idle Mode, when the display is dark, the tumbler will repeat the last drying cycle. If the cycle time is adjusted before the cycle is started, the time displayed when the start button was pressed will be used for future cycles.

Figure 5

IMPORTANT: To stop the tumbler at any time during the cycle, OPEN DOOR. If the loading door or lint panel door is opened during the cycle, the heating system will shut off and the motor will stop.

To restart the cycle, both doors must be closed and the START button must be pressed in.

If the load cools to 90°F before cool down time expires, the control will flash “Lr” (load ready) in the heat time display. If the door is not opened, the tumbler completes the selected cool down time. If the door is opened after reaching “Lr” temperature, the cycle will be terminated.

NOTE: If display shows an error code, refer to

Error Codes section.

6. When the cycle is complete, open door and remove the laundry. Anti-wrinkle feature will tumble the load without heat for 30 seconds every 2 minutes for 1 hour OR until the loading door is opened.

NOTE: This machine includes an anti-wrinkle extended tumble feature. After the drying cycle is complete, the cylinder will tumble without heat every few minutes. The intermittent tumbling will continue for one hour or until the door is opened.

70400301 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 11

Operating Instructions

Error Codes

WARNING

To reduce the risk of electric shock, fire, explosion, serious injury or death:

• Disconnect electric power to the tumbler before servicing.

• Close gas shut-off valve to gas tumbler before servicing.

• Close steam valve to steam tumbler before servicing.

• Never start the tumbler with any guards/panels removed.

• Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded.

W002

Display

OP

SH

AF - 1

AF - 2

Definition

Open thermistor error

Shorted thermistor error

Airflow switch closed when cycle started

Airflow switch failed to close after cycle started

Corrective Action

Check thermistor. Replace if inoperative.

Check wiring diagram between control and thermistor. Refer to wiring diagram for proper wiring.

Check control. Replace if inoperative.

Check thermistor. Replace if inoperative.

Check wiring between control and thermistor.

Refer to wiring diagram for proper wiring.

Check control. Replace if inoperative.

Check airflow switch. Replace if inoperative.

● Check airflow switch. Replace if inoperative.

12 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70400301

Operating Instructions

TMB2123N

Single Drop Control

SD and SX Control Suffixes

1. Select HIGH, MED, LOW or NO HEAT by turning the temperature knob.

HIGH temperature 190°F (87°C)

MED temperature 160°F (71°C)

LOW temperature 130°F (54°C)

2. Insert the coin(s) in the coin slot.

3. Press START button to start tumbler.

IMPORTANT: To stop the tumbler at any time during the cycle, OPEN DOOR. To restart the tumbler, CLOSE door and press START button.

NOTE: If display shows an error code, refer to

Error Codes section.

4. When the cycle is complete, open door and remove the laundry.

NOTE: This machine includes an extended tumble feature. Starting 20 minutes after a cycle ends, the cylinder will tumble for two minutes every hour without heat, up to 18 hours or until door is opened.

Figure 6

Preliminary Control Information

Power-Up Mode

When power is applied to the tumbler the control will enter Ready Mode, unless a cycle was in process prior to a disruption of power. If a power disruption is less than 5 seconds, with a cycle in process, the control will enter Run Mode once power is restored and continue the cycle. If a power disruption is more than 5 seconds, with a cycle in process, the control will enter Start

Mode once power is restored.

If the dry time dipswitch settings have not changed from the factory default, the IN USE LED will flash two to five times, depending on model.

Ready Mode

In Ready Mode, the control waits for the vend to be satisfied before entering Start Mode.

Start Mode

In Start Mode, the vend has been satisfied, but the

Start button has not been pressed. The IN USE LED will be lit. The timer will not count down until the

Start button is pressed.

70400301 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 13

Operating Instructions

Run Mode

In Run Mode, the control is running a cycle. The IN

USE LED is lit.

Door Open Mode

In Door Open Mode, the control turns off the heater and motor when the door is opened during a run cycle. The timer will continue to count down time and the IN USE LED is lit.

End of Cycle Mode

In End of Cycle Mode, a cycle is complete and the

IN USE LED is off. The control remains in this mode until the door is opened or additional vend has been satisfied.

Topoffs

Any time the control receives a coin drop pulse during a cycle it will add the programmed dry time to the time currently remaining in the cycle. The maximum cycle time is 99 minutes, the control will not add time beyond 99 minutes. The cool down time will not change.

If the control receives a coin drop pulse during cool down the IN USE LED will flash briefly to indicate the coin input, the machine will exit cool down and it will start heating. The cycle time will be equal to the programmed dry time

Temperature Selector Switch

For five minutes after the control is powered up, there is a diagnostic feature that allows the temperature selector switches to be tested.

When the temperature selector is changed, the new setting is displayed by flashing the IN USE LED as follows:

High/Normal: 4 flashes

Medium/PP: 3 flashes

Low/Delicate: 2 flashes

No Heat: 1 flash

NOTE: To change dipswitch settings refer to

Installation Manual.

To Program a Short Test Cycle:

1. Unplug machine power cord.

2. Write down machine control dip switch settings, then set them all to the off position. Refer to

Figure 7.

3. Plug machine in and start a cycle.

NOTE: With all control dip switches off, the total cycle time will be 1 minute long.

4. Once all testing is complete, unplug machine and re-set dip switches to their original settings.

5. Plug machine in.

O

N

1 2 3 4 5 6 7 8

Figure 7

Error Codes

WARNING

To reduce the risk of electric shock, fire, explosion, serious injury or death:

• Disconnect electric power to the tumbler before servicing.

• Close gas shut-off valve to gas tumbler before servicing.

• Close steam valve to steam tumbler before servicing.

• Never start the tumbler with any guards/panels removed.

• Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded.

TMB2216N

W002

Display

AF (flashing)

Definition

Airflow switch opened/closed 5 or more times in a running cycle.

Corrective Action

Check airflow switch. Replace if inoperative.

14 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70400301

Operating Instructions

25 C

TMB2261N

DX4 Coin Control

3V and 3X Control Suffixes

1. Open door and fill drum with clothes

2. Close door.

3. Insert the coin(s) in the coin slot.

4. Press and release one of the cycle buttons to select a cycle and start the tumbler. Refer to

Table 1.

To use a custom cycle, refer to the Programming

Manual.

Figure 8

NOTE: Drying times will be dependent on the number of coins that are inserted in the coin slot.

IMPORTANT: To stop the tumbler at any time during the cycle, OPEN DOOR. To restart the tumbler, CLOSE door and press START button.

5. When the cycle is complete, open door and remove the laundry.

Left Button

Middle Button

Right Button

Temperature

104°F (40°C)

140°F (60°C)

176°F (80°C)

Drying Time

Varies

Varies

Varies

Table 1

Cool Down Time

2 min.

2 min.

2 min.

70400301 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 15

Operating Instructions

TMB2260N

Figure 9

DX4 OPL Control

3O Control Suffix

1. Open door and fill drum with clothes.

2. Press and release one of the cycle buttons to select a cycle and start the tumbler. Refer to

Table 2.

To use a custom cycle, refer to the Programming

Manual.

IMPORTANT: To stop the tumbler at any time during the cycle, OPEN DOOR. To restart the tumbler, CLOSE door and press START button.

3. When the cycle is complete, open door and remove the laundry.

Left Button

Middle Button

Right Button

Temperature

104°F (40°C)

140°F (60°C)

176°F (80°C)

Drying Time

30 min.

30 min.

35 min.

Table 2

Cool Down Time

2 min.

2 min.

2 min.

16 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70400301

Operating Instructions

Diagnostic Microprocessor Control

General Operation

The Diagnostic Microprocessor Control (DMP) is designed to manage the drying and cooling cycles of the tumbler. The controller is also programmed from the factory with five different default programs as described below. The operator has the flexibility to select the time for the drying and the cool down cycles and the drying temperature. The operator may also select either reversing or nonreversing basket action only if the tumbler is equipped for reversing. The operator may also reprogram the default programs.

See Programming.

Default Programs

Programs

1 – Towels

2 – Sheets

3 – Misc-1

4 – Misc-2

5 – Extra Dry

Dry Time (Min.)

40

30

30

25

5

Cool Time (Min.)

5

5

5

5

2

Temp. Set Point

185º/195ºF

(85º/91ºC)

165ºF (74ºC)

150ºF (66ºC)

135ºF (57ºC)

150ºF (66ºC)

Reversing

NOTE: If an altered program is determined to be corrupted, the default program settings will be used.

No

Yes

No

Yes

No

Table 3

Features

Drying time: 0-60 minutes

Cooling time: 2-60 minutes

LED display of cycle time, set temperature, and actual temperature

Thermistor controlled temperature

Safety tumble cycle

Buzzer for end of cycle, audible alarm

Reversing/Nonreversing selection

Five user programmable programs

RPM display – when equipped with rotational

sensor only

Monitors the lint door switch operation

Monitors the thermistor for operation

The minimum drying time is 0 minutes, and the minimum cooling time is 2 minutes. The maximum drying or cooling time is 60 minutes. The drying temperature may be set from 100ºF (38ºC) to

185º/195ºF (85º/91ºC). The drying time, cooling time, or temperature may be modified during an operating cycle.

If it is necessary to reset the drying and cooling times for the current cycle, press STOP once to stop the tumbler. Press STOP again to cancel the cycle.

If it is necessary to change programs during a current cycle, press STOP once to stop the tumbler and press

STOP again to cancel the current cycle.

70400301 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 17

Operating Instructions

DMP OPL Models

DO Control Suffix

Description of the OPL Control Panel

Refer to Figure 10.

6

5

3

4

1

2

5

6

7

8

9

10

11

12

8

4

1

4

5

2

3

DRYING

COOLING

TEMPERATURE

REV START STOP

(CANCEL)

7

9

10

11

12

8

3 1 2

TMB1956N

TMB1956N

START. Starts or resumes the current program or cycle.

STOP. Temporarily halts the current cycle or cancels the current program.

Reversing/Nonreversing (REV). Changes the selection between reversing and nonreversing cylinder action.

Reversing LED. Illuminated when set for reversing.

Up/Down Arrows. Increases or decreases the value in the display. In conjunction with the DISPLAY button, these buttons are used to adjust the drying time, cooling time, temperature, clockwise time, dwell time, counter-clockwise time, and minutes per coin (Coin only).

Display. Displays the drying time, cooling time, drying temperature and diagnostic codes.

Program Select. This button toggles through the five user programmable programs. Holding this button will save a program, as indicated in Programming.

User Program LEDs. Illumination shows which user program is currently being displayed.

Display Select. Toggles the display between the drying time, cooling time, and temperature settings. Pressing the

Display button for 3 seconds allows the user to display the drying cycle temperature.

DRYING LED. Illuminated when in the drying cycle.

COOLING LED. Illuminated when in the cooling cycle, or when the display is currently showing the time for the cooling cycle.

TEMPERATURE LED. Illuminated when the display is showing the temperature setting.

Figure 10

18 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70400301

Operating Instructions

DMP OPL Features

DIP Switch Settings

The DMP has an 8 position DIP switch bank that is accessible from the back of the control board. By switching these DIP switches, it is possible for the operator to customize the display and some of the operating features of the tumbler.

Function

1

2

3

4

5

6

7

8

OPL

Tumbler Type

Temperature Units

Local/Remote

Reversing

Empty

Empty

Buzzer Timer

Safety Tumble (OPL) or Coin Count/Pay

(Coin)

Programming

OFF

OFF

ON

ON

ON

ON

ON

OFF

Coin

ON

OFF

ON

ON

ON

ON

OFF

OFF

#1

OFF

OFF

ON

ON

OPL=Off; Coin=On

ºF=Off; ºC=On

Local=On; Remote=Off

Always ON

Always ON

5 Sec=Off; Continuous=On

#7 DIP SWITCH

ON

OFF

ON

OFF

SAFETY TUMBLE

NO SAFETY TUMBLE

COIN COUNT

PAY

Disable=Off; Enable=On

DIP Switch Functions Explained

1. Tumbler Type: This DIP switch selects the type of tumbler, i.e., OPL or Coin.

2. Temperature Units: Selects ºF or ºC for the temperature display. Factory setting is for ºF.

3. Local/Remote Reversing: Preset at the factory; usually for local reversing. Remote reversing for use with Reversing Timer Board only.

4. Empty: Preset at the factory; always ON.

5. Empty: Preset at the factory; always ON.

6. Buzzer Timer: This DIP switch determines the length of time that the end of cycle buzzer will remain on. “OFF” indicates that the buzzer will sound for 5 seconds when the drying cycle is completed. “ON” indicates that the buzzer will sound continuously until the STOP button is pressed or the loading door is opened.

Table 4

7. Safety Tumble (OPL) or Coin count/Pay (Coin):

If DIP switch #1 is set for OPL, then DIP switch

#7 in the ON position enables the safety tumble.

If DIP switch #1 is set for Coin, then DIP switch

#7 in the ON position enables the display of the coin count. DIP switch #7 in the OFF position enables the display of “PAy,” to indicate that coins are needed to run the tumbler.

8. Programming: This switch enables or disables the programming feature and should normally be in the OFF position.

70400301 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 19

Operating Instructions

DMP Coin

DV and DX Control Suffixes

Description of The Coin Control Panel

Refer to Figure 11.

1

2

3

6

7

4

5

8

9

1

2

3

4

5

6

MINUTES

HIGH

MEDIUM

PERM. PRESS

LOW

DRYING

COOLING

TEMP

START

INSTRUCTIONS

1

2

3

INSERT COIN (S)

SELECT TEMP.

PUSH START

9

8

TMB1955N

7

TMB1955N

Clock Symbol. This symbol of a clock indicates that the time in the display is counting down to zero.

Display. Displays the drying time, cooling time, drying temperature, and diagnostics.

Hidden Keys. Used for programming in the coin mode – increases or decreases the value in the display. In conjunction with the START button, these buttons are used to adjust the drying time, cooling time, temperature, clockwise time, dwell time, counterclockwise time, and minutes per coin.

Temperature LEDs. Indicate temperature setting.

DRYING LED. Illuminated when in the drying cycle.

INSTRUCTIONS. Instructions to start a drying cycle.

COOLING LED. Illuminated when in the cooling cycle or when the display is currently showing the time for the cooling cycle.

START. Starts or resumes the current program or cycle

Temperature Select. This button toggles through the three temperature selections.

Figure 11

20 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70400301

DMP Coin Features

Coin Keypad Interface

- START button to start or resume a cycle.

- TEMP button to select HIGH, MEDIUM, or LOW temperature.

- Two hidden buttons to increment or decrement the programmable time and temperature options.

Power-Up

Upon applying power to the tumbler, the display will show “PAy” and the DRYING and COOLING LEDs will be off until coins are deposited to increase the tumbler run time. When time is displayed, the default

(LOW) temperature setting LED will be on until a different temperature setting is selected.

Power Failure

If a power loss occurs during operation, a cycle will not resume until the START button is pressed. To cancel the remaining cycle, press the internal CLEAR button.

Coin Operation

The tumbler run time is determined by the preprogrammed run time per coin and the number of coins deposited into the tumbler. The maximum time that can be accumulated and displayed is 99 minutes.

The drying time is the difference between the run time and the cooling time. The cooling time is preprogrammed to be 2 to 5 minutes. The drying temperature can be selected from LOW, MEDIUM, or

HIGH temperature settings by pressing the TEMP button.

Coin Programming

The Coin board programming mode can only be entered when “PAy” is displayed. DIP switch #7 must be in the OFF position.

Programming is enabled by setting DIP switch #8 to the ON position.

The programming mode is entered by pressing and holding the CLEAR button for three seconds.

The programming follows the following parameter order:

1. Tumbler run time per coin (DRYING),

COOLING time, HIGH temperature setpoint,

MEDIUM temperature setpoint, LOW temperature setpoint.

2. An LED will be on to indicate which parameter is flashing on the display.

Operating Instructions

3. The hidden front panel increment and decrement keys are used to change the value.

4. The CLEAR button is used to recall the default value.

5. The START button is used to step to the next parameter.

6. After the last parameter, “End” will be flashing.

7. Press the START button one last time to store the settings and exit the program mode.

8. “PAy” will be displayed.

9. If it is determined that the data did not program correctly, the error message “E2F” will flash for

4 seconds, and then the default coin parameters will be used.

The tumbler run time per coin is programmable for 1 to 20 minutes with the default preset to 10 minutes.

The cooling run time is programmable from 2 to

5 minutes with the default preset to 2 minutes.

The three temperatures setpoints are programmable for

100ºF (38ºC) to 185º/195ºF (85º/90ºC) with the following default settings:

- HIGH equal to 185ºF (85ºC)

- MEDIUM equal to 150ºF (66ºC)

- LOW equal to 135ºF (57ºC)

Stop

When in the Coin mode, the tumbler will stop if the tumbler door is opened while the tumbler is running. If the CLEAR button, located behind the board, is pressed, the tumbler will stop, the tumbler time will be zeroed and the display will show “PAy.”

Coin Count

The unit will count the number of coins deposited.

Setting DIP switch #7 to the ON position will display the coin count since it was the last reset.

To reset the count, press the CLEAR button and “00” will be displayed.

If the coin count is greater than “999,” the display will flash “999.”

Setting DIP switch #7 to the OFF position will return the display to “PAy.”

70400301 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 21

Operating Instructions

Programming

1. Set DIP switch #8 to the ON position.

2. Select the desired program number to change.

The LED should be flashing.

3. Select DRY TIME. Set the time with the Up/

Down arrows.

4. Select COOL TIME. Set the time with the Up/

Down arrows.

5. Select TEMPERATURE. Set the temperature with the Up/Down arrows.

6. Select reversing REV (illuminated) or nonreversing REV (not illuminated). To change basket direction and dwell time, see Reversing

Operation.

7. Press and hold the Program Select button about

3 seconds until the LED stops flashing. The selected program number is now programmed. If the Program button is pressed for less than

3 seconds, the controller will cancel the program and display the next program’s settings. If not programmed correctly, the display will flash

“E2F” for 4 seconds, and the default settings will be used. Follow steps 4 through 7 to reprogram any program number. When finished, set DIP switch #8 to OFF. The programs are now stored.

8. During the Program Mode, if the Up/Down arrows, REV, or Display button is not pressed within 10 seconds, the default program settings will be used.

9. Temporary Reprogramming of Current Programs

(OPL ONLY)

10. The Drying Time, Cooling Time, Temperature, and Reversing Mode of a program currently in use may be modified simply by adjusting any or all of the program parameters for that program, as needed. Once a modification has been made, the current program LED will flash indicating that it has been modified.

11. Use the Up/Down arrows to adjust program time.

12. Use the Display Select button to choose between

Drying Time, Cooling Time, and Temperature.

Then use the Up/Down arrows to adjust the times and temperature.

13. Toggle between reversing REV (illuminated) or nonreversing REV (not illuminated). (Only for tumblers with the reversing option.)

14. To cancel this temporary programming mode push the STOP button once to stop the current cycle and once more to cancel the modified program settings. The program will revert back to its original settings.

Reversing Operation

1. When the LOCAL reversing operation is selected, the reversing times are stored in the

EEPROM which is located on the controller board. If the values stored are determined to be invalid, the clockwise and counterclockwise times will default to 60 seconds, and the dwell time will default to 4 seconds.

2. The reversing time program has the following sequence: (1) clockwise time, (2) dwell time, and

(3) counterclockwise time.

3. To program new reversing times DIP switches #3 and #8 must be on.

4. Press and hold the reverse button (REV) for

3 seconds to display the clockwise time.

5. Use the Up/Down arrows to set the clockwise time within the range of 30-120 seconds.

6. Press REV to display the dwell time.

7. Use the Up/Down arrows to change the dwell time within the range of 3-10 seconds.

8. Press the REV button to display the counterclockwise time.

9. Use the Up/Down arrows to change the counterclockwise time within the range of

30-120 seconds.

10. Press the REV button to save these settings and leave DIP switch #3 in the ON position and flip

DIP switch #8 to the OFF position.

When the DMP controller is retrofitted to an existing tumbler with the reversing feature, off board reversing will be required and DIP switch #3 on the DMP must be in the OFF position and the DMP must be connected to the Reversing Timer Board for proper operation. The DMP settings for clockwise, dwell, and counterclockwise times are no longer valid when used with the Reversing Board. Instead these settings are made on the Reversing Timer Board.

22 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70400301

Rotation Sensor

The rotation sensor must “read” the key on the basket shaft or pulley. The sensor must be set approximately

1/4 inch from the key or pulley. Look for the light on the sensor to come on as the key passes the sensor; this is a correctly operating sensor. If no light appears, either the sensor is out of range or the key/pulley or the sensor is bad. In addition, if the light stays on continuously, then the sensor is too close to the component or the sensor is bad.

Safety Tumble/Anti-Wrinkle

At the end of the cool down cycle, the tumbler will stop and display “END.” The DMP control will automatically rotate the basket for 5 seconds every

2 minutes for a total of 20 minutes, until some function of the tumbler is activated/deactivated by the user.

Operating Instructions

Operational Check for the Board Diagnostics

1. “dor” indicates that the loading or lint door is open.

2. Cycle the tumbler to check if the buzzer activates.

3. “P-F” indicates that the thermistor is short circuited or open circuited.

4. “bbt” indicates a broken belt condition or a faulty rotation sensor. (Only available on tumblers with the rotation sensor.)

5. Hold the START button to display the drum

RPM’s; the display will read “r##” where ## are the RPM’s. (Only available on tumblers with the rotation sensor.)

70400301 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 23

Operating Instructions

Ignition Control Operation

Power Up

After 24 VAC is applied to the ignition control pins

24V and GND, the Diagnostic LED on the ignition control will turn orange/yellow. If a fault is detected the ignition control will enter Lockout Mode. If no faults are detected, the Diagnostic LED will turn

Green and the ignition control will enter Standby

Mode.

Standby Mode

While in Standby Mode, the ignition control will continually monitor the system for faults. Once

24VAC is applied to terminals TH and GND on the control, the ignition control will enter Start Up Mode.

Start Up Mode

During Start Up Mode, the ignition control will monitor the system for faults and begin the ignition sequence. If no faults are present, the ignition control will begin the ignition sequence by entering an 18 second waiting period. During this time the Green

LED on the ignition control will switch between Red and Green, before maintaining a Green color.

After the waiting period, the ignition control will turn on the igniter and gas valve. The igniter will remain on until a flame is sensed, or up to 10 seconds.

Once a flame has been sensed the ignition control will stop sparking, the gas valve will remain on and ignition control will enter Run Mode.

If a flame is not sensed, the ignition control will then begin two additional retrials for ignition. The ignition control will re-enter the 18 seconds waiting period before the ignition control makes another attempt at ignition. If the three attempts at ignition fail, the ignition control will enter Lockout Mode.

Run Mode

While in Run Mode the ignition control leaves the gas valve on, monitors the flame signal, and leaves the igniter off.

If a flame signal is lost during Run Mode, one additional retrial for ignition will take place within one second. The ignition control will restore the spark for approximately 10 seconds. If the ignition re-attempt fails, the ignition control will enter Lockout Mode.

The ignition control will remain in Run Mode until

24VAC is removed from terminals TH and GND on the control.

Termination of Flame

The flame will go out when power is removed from ignition control. The ignition control will turn off the gas valve and enter Standby Mode.

Lockout Mode

When Lockout Mode is entered, the ignition control will remove power to the gas valve, the igniter will turn off, the Lockout/Reset Light will turn on, and the

Diagnostic LED will display the appropriate Error

Code.

Lockout Manual Reset

Lockout Mode is cleared by pressing an external reset switch for three seconds. The ignition control will clear all error codes and enter Standby Mode. During

Lockout Manual Reset, the Diagnostic LED on the ignition control flashes red and orange, and the Reset

Light remains on until the ignition control is reset.

After the Reset Light turns off, stop pressing the switch. Holding the reset for three seconds after lockout has been cleared will cause a fault and result in entering Lockout Mode again.

System Tests

The following system tests are performed during normal operation. System tests are performed at a minimum of every 24 hours.

Low Voltage Detection

If the voltage between terminals TH and GND on the control is below 18.75VAC +/- 0.75VAC for more than

3 seconds the ignition control will turn off the gas valve and will not attempt to spark. The Diagnostic

LED will display Error Code 5. The ignition control will not enter Lockout Mode if a low voltage condition is detected, but will enter Standby Mode and wait for the low voltage condition to be cleared.

If the voltage between terminals TH and GND on the control rises above 19.75VAC +/- 0.1VAC for at least 3 seconds, the ignition control will then enter Start Up

Mode.

Low Voltage Detection test is disabled during Run

Mode.

24 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70400301

Gas Valve

The ignition control verifies that the gas valve is connected. Failure of this test results in the ignition control entering Lockout Mode with the Diagnostic

LED displaying Error Code 2.

Flame Probe Tests

Unexpected Presence of Flame

The Unexpected Presence of Flame test is performed when no flame is expected. Failure of this test results in the ignition control entering Lockout Mode with the

Diagnostic LED displaying Error Code 3.

Flame Monitoring

During the Flame Monitoring test, the flame is checked to ensure the gas is being burned when the gas valve is on. Failure of this test will result in the ignition control entering Lockout Mode with the

Diagnostic LED displaying Error Code 3.

Error

Code

1

2

3

4

5

6

DGN LED status

Red

2 Red Flashes

3 Red Flashes

4 Red Flashes

Slow Red and Green Flashes

Fast Red and Orange Flashes

Operating Instructions

Diagnostic LED (DGN LED) / Error Codes

The Diagnostic LED or DGN LED is located by the power connector on the ignition control. Refer to

Figure 12. The Diagnostic LED will indicate the status of the ignition control. Refer to Table 5.

LED Color

Orange-Yellow

Green

Red

Description

Initialization

Standby / Normal Operation

Fault Indication Code

Table 5

The Diagnostic LED will flash error codes one half second on and one half second off. Error codes are separated by a one second pause before the code is repeated.

Fault Type

Ignition Control Internal Failure

Gas Valve Not Connected

Ignition/Flame Sense Failure

Reset Switch is Shorted

Low Voltage Detection

Ignition Control is in Reset Delay

1

1 Diagnostic (DGN) LED

Figure 12

TMB2176N

70400301 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 25

26

Maintenance

WARNING

To reduce the risk of electric shock, fire, explosion, serious injury or death:

• Disconnect electric power to the tumbler before servicing.

• Close gas shut-off valve to gas tumbler before servicing.

• Close steam valve to steam tumbler before servicing.

• Never start the tumbler with any guards/panels removed.

• Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded.

Daily

1. Inspect the area surrounding tumblers, remove all combustible materials, including lint, before operating the machines.

2. Check cylinder for foreign objects to avoid damage to clothing and equipment.

3. Clean lint from lint compartment and screen to maintain proper airflow and avoid overheating.

W002 e. Carefully wipe any accumulated lint off of the cabinet high limit thermostat and thermistor.

Failure to do so will allow a buildup of lint in this area to act as an insulator, causing the

tumbler to overheat. Refer to Figure 13.

f. Replace the lint compartment panel on the tumbler ensuring a tight fit, and lock if applicable.

1

WARNING

To reduce the risk of serious injury, do not open the lint panel while the tumbler is in operation. Before cleaning the lint screen, open tumbler door and allow cylinder to completely stop.

W410 a. Open the lint panel.

b. Remove all accumulated lint in the lint compartment area. Lightly brush any lint that may be left on the lint screen. Lint left in the lint compartment is drawn back onto the lint screen and will restrict airflow.

c. Be sure the lint screen is not torn. If it is, replace immediately. A torn lint screen allows lint to pass from the tumbler to the ductwork system and may restrict airflow.

d. The lint screen is designed to completely cover the entire opening in the lint screen panel. Be sure that it does so. Excessive gaps between the lint screen and the lint screen panel allow lint to pass into the ductwork system and may restrict airflow.

1

2

Thermostat and Thermistor

Lint Screen

Figure 13

2

TMB808N

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70400301

Maintenance

WARNING

To reduce the risk of electric shock, fire, explosion, serious injury or death:

• Disconnect electric power to the tumbler before servicing.

• Close gas shut-off valve to gas tumbler before servicing.

• Close steam valve to steam tumbler before servicing.

• Never start the tumbler with any guards/panels removed.

• Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded.

Monthly

1. Remove lint and debris from inside exhaust duct to maintain proper airflow and avoid overheating.

a. Remove external duct and duct access covers, if present.

b. Clean inside of duct with a vacuum.

c. Clean dampers and make sure they operate freely.

d. Replace duct and all access covers before returning to operation.

2. Ensure even lint distribution over lint screen, replace if distribution of lint is uneven to maintain proper airflow and avoid overheating.

3. Carefully wipe any accumulated lint off the cabinet high limit thermostat and thermistor, including perforated cover. Lint buildup will act as an insulator, causing machine to overheat.

4. Clean lint and debris buildup from blower to maintain proper airflow, to avoid overheating and prevent possible vibration.

W002

Bi-Annually

1. Check mounting hardware for any loose nuts, bolts or screws.

2. Check gas connections for leakage.

3. Check for loose electrical connections.

4. Check steam connections for looseness and leakage.

5. Remove all front panels and vacuum, including coin drop mechanisms.

6. Check cylinder and front panel seals.

7. Inspect cabinet and inner panels for any damage, replace or repair as needed.

8. Clean burner tubes of any lint buildup.

Annually

1. Remove burner tubes and clean using water and a brush.

Quarterly

1. Use a vacuum to clean air vents on drive motors.

2. Use a vacuum to clean lint from rear limit thermostat cover.

3. Check and clean steam coils, if applicable.

4. Check flow of combustion and ventilation air.

5. Check belt tension and condition. Replace worn or cracked belts.

70400301 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 27

Maintenance

WARNING

To reduce the risk of electric shock, fire, explosion, serious injury or death:

• Disconnect electric power to the tumbler before servicing.

• Close gas shut-off valve to gas tumbler before servicing.

• Close steam valve to steam tumbler before servicing.

• Never start the tumbler with any guards/panels removed.

• Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded.

Daily Maintenance

Inspect the area surrounding tumblers, remove all combustible materials, including lint, before operating the machine.

Check cylinder for foreign objects to avoid damage to clothing and equipment.

Clean lint from lint compartment and screen to maintain proper airflow and avoid overheating.

Monthly Maintenance

Remove lint and debris from inside exhaust duct to maintain proper airflow and avoid overheating.

Ensure even lint distribution over lint screen, replace if distribution of lint is uneven to maintain proper airflow and avoid overheating.

Carefully wipe any accumulated lint off the cabinet high limit thermostat and thermistor, including perforated cover.

Lint buildup will act as an insulator, causing machine to overheat.

Clean lint and debris buildup from blower to maintain proper airflow, to avoid overheating and prevent possible vibration.

W002

28 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70400301

Maintenance

WARNING

To reduce the risk of electric shock, fire, explosion, serious injury or death:

• Disconnect electric power to the tumbler before servicing.

• Close gas shut-off valve to gas tumbler before servicing.

• Close steam valve to steam tumbler before servicing.

• Never start the tumbler with any guards/panels removed.

• Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded.

Quarterly Maintenance

Use a vacuum to clean air vents on drive motors.

Use a vacuum to clean lint from rear limit thermostat cover.

W002

Check and clean steam coils.

Check flow of combustion and ventilation air.

Check belt tension and condition.

Replace worn or cracked belts.

Bi-Annually Maintenance

Check mounting hardware for any loose nuts, bolts or screws.

Check gas connections for leakage.

Check for loose electrical connections.

Check steam connections for looseness and leakage.

Remove all front panels and vacuum, including coin drop mechanisms.

Check cylinder and front panel seals.

Inspect cabinet and inner panels for any damage, replace or repair as needed.

Clean burner tubes of any lint buildup.

70400301 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 29

Maintenance

Annual Maintenance

Remove burner tubes and clean using water and a brush.

30 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70400301

Before You Call for Service

Won’t

Start

Won’t

Heat

Clothes

Not Dry

Customer Service

If literature or replacement parts are required, contact the source from which the machine was purchased or contact Alliance Laundry Systems at (920) 748-3950 for the name and address of the nearest authorized parts distributor.

For technical assistance, call (920) 748-3121.

Possible Reason – Corrective Actions

Insert correct coin(s) or valid card if applicable.

Close the loading door tightly.

Close lint panel tightly.

Press the PUSH-TO-START or START pad/button.

Be sure power cord is plugged all the way into the electrical outlet.

Drying timer is in OFF position.

Check the main fuse and circuit breaker.

Check fuses located in the machine.

Insufficient airflow.

Gas shut-off valve in OFF position.

Are controls properly set?

Broken drive belt. Call the service person.

Tumbler is in Cool Down Mode.

Lint screen clogged. Clean lint screen.

Exhaust duct to outside is blocked. Clean out.

70400301 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 31

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals