ROOM AIR CONDITIONER

INDOOR UNIT

AS070VE/DOK

AS071VE/DOK

AS074VE/DOK

AS075VE/DOK

AS090VE/DOK

AS091VE/DOK

AS094VE/DOK

AS095VE/DOK

AS120VE/DOK

AS121VE/DOK

AS124VE/DOK

AS125VE/DOK

OUTDOOR UNIT

AX070VE/DOK

AX071VE/DOK

AX074VE/DOK

AX075VE/DOK

AX090VE/DOK

AX091VE/DOK

AX094VE/DOK

AX095VE/DOK

AX120VE/DOK

AX121VE/DOK

AX124VE/DOK

AX125VE/DOK

SERVICE Manual

AIR CONDITIONER

1. Pre c a u t i o n s

CONTENTS

2. Product Specifications

3. Operating Instructions and

I n s t a l l a t i o n

4. Disassembly and Reassembly

5. Tro u b l e s h o o t i n g

6. Exploded Views and Parts List

7. Block Diagrams

8. PCB Diagrams

9. Wiring Diagrams

10. Schematic Diagrams

© Samsung Electronics Co., Ltd. JAN. 1998.

Printed in Korea.

Code No. DB81-10123A(1)

1. Precautions

1 . Warning: Prior to re p a i r, disconnect the power cord from the circuit bre a k e r.

2 . Use proper parts: Use only exact re p l a c ement parts. (Also, we recommend re p l a c i n g parts rather than repairing them.)

3 . Use the proper tools: Use the proper tools and test equipment, and know how to use them. Using defective tools or test equipment may cause problems later- i n t e r m i t t e n t contact, for example.

4 . Power Cord: Prior to re p a i r, check the power cord and replace it if necessary.

5 . Avoid using an extension cord, and avoid tapping into a power cord. This practice may result in malfunction or fire .

6 . After completing repairs and re a s s e m b l y, check the insulation resistance. Pro c e d u re :

Prior to applying power, measure the re s i stance between the power cord and the g round terminal. The resistance must be g reater than 30 megohms.

7 . Make sure that the grounds are adequate.

8 . Make sure that the installation conditions a re satisfactory. Relocate the unit if necess a r y.

9 . Keep children away from the unit while it is being re p a i re d .

1 0 . Be sure to clean the unit and its surro u n ding are a .

Fig. 1-1 Avoid Dangerous Contact

Fig. 1-2 No Tapping and No Extension Cords

Fig. 1-3 No Kids Nearby!

Samsung Electronics

Fig. 1-4 Clean the Unit

1-1

M E M O

1-2

Samsung Electronics

2. Product Specifications

2-1 Table

Model

Item

Type

Performance

Power

Size

Cooling

Dehumiditying

Air volume

Noise

Cooling

Cooling

Energy efficiency ratio Cooling

Power

Power Consumption Cooling

Operating Current Cooling

Cooling Power factor

Starting current

Power cord Length

Number of core wire

-

BTU/h

I/h m3/min dB

BTU/h.W

V-Hz

W

A

%

A m

Fuse capacity

Outer dimension

Weight

Refrigerant pipe

Width x Height x Depth

Liquid

GAS

Drain hose

Compressor Type

Motor Type

Rated output

A mm inch kg

OD(mm)x L(m)

ID(mm)x L(m)

W

Blower Type

Motor Type

Rated output

Heat exchanger

Refrigerant control unit

Freezer oil capacity

Refrigerant to change(R-22)

Protection device

W

A S 0 7 0 V E / A S 0 7 1 V E / A S 0 7 4 V E / A S 0 7 5 V E

Indoor unit Outdoor unit

Wall-mounting

7500

1.2

6.0

35 45

11.2

1-220 / 240-50

670

2.8

99.7

17.0

2 -

250V 10/16A

3.15

-

815x298x182 720x525x245

32.08x11.73x7.17

28.35x20.67x9.65

9.6

27

ø6.35 x 5

ø9.52 x 5

ø17 x 2000

-

-

Rotary

-

675

Cross-fan

Resin

Propeller

Die casting

35 15

2Row 12Step 1Row 20Step

-

CAPILLARY TUBE

280

670

MST24AMN

-12008

Cooling test Condition

Maximum operation Condition

A S 0 7 0 V D / A S 0 7 1 V D / A S 0 7 4 V D / A S 0 7 5 V D

Indoor unit Outdoor unit

Wall-mounting

7500

1.2

6.0

35 45

11.2

1-200 / 220-50

670

3.2

95.2

17.0

2 -

250V 10/16A

3.15

-

815x298x182 720x525x245

32.08x11.73x7.17

28.35x20.67x9.65

9.6

27

ø6.35 x 5

ø9.52 x 5

ø17 x 2000

-

-

Rotary

-

685

Cross-fan

Resin

Propeller

Die casting

35 15

2Row 12Step 1Row 20Step

-

CAPILLARY TUBE

280

690

MST24AMM

-12008

INDOOR UNIT : DB27°C WB19°C

INDOOR UNIT : DB32°C WB23°C

A S 0 9 0 V E / A S 0 9 1 V E / A S 0 9 4 V E / A S 0 9 5 V E

Indoor unit Outdoor unit

Wall-mounting

9000

1.6

6.1

35 45

10.2

1-220 / 240-50

880

4.0

91.7

22.0

2 -

250V 10/16A

3.15

-

815x298x182 720x525x245

32.08x11.73x7.17

28.35x20.67x9.65

9.6

28

ø6.35 x 5

ø9.52 x 5

ø17 x 2000

-

-

Rotary

-

895

Cross-fan

Resin

Propeller

Steel

35 15

2Row 12Step 1Row 20Step

-

CAPILLARY TUBE

360

800

MRA12037

-12007

A S 0 9 0 V D / A S 0 9 1 V D / A S 0 9 4 V D / A S 0 9 5 V D

Indoor unit Outdoor unit

Wall-mounting

9000

1.6

6.1

35 45

10.2

1-220 / 220-50

880

4.2

95.2

22.0

2 -

250V 10/16A

3.15

-

815x298x182 720x525x245

32.08x11.73x7.17

28.35x20.67x9.65

9.6

28

ø6.35 x 5

ø9.52 x 5

ø17 x 2000

-

-

Rotary

-

890

Cross-fan

Resin

Propeller

Steel

35 15

2Row 12Step 1Row 20Step

-

CAPILLARY TUBE

360

740

MRA12056

-12007

OUTDOOR UNIT : DB35°C WB24°C

OUTDOOR UNIT : DB43°C WB26°C

A S 1 2 0 V E / A S 1 2 1 V E / A S 1 2 4 V E / A S 1 2 5 V E

Indoor unit Outdoor unit

Wall-mounting

12000

1.9

7.8

38 49

10.2

1-220 / 240-50

1180

5.0

98.3

30.0

2 -

250V 10/16A

3.15

-

815x298x182 720x525x245

32.08x11.73x7.17

28.35x20.67x9.65

9.6

31

ø6.35 x 5

ø12.7 x 5

ø17 x 2000

-

-

Rotary

-

1210

Cross-fan

Resin

Propeller

Die casting

35 20

2Row 12Step 1Row 20Step

-

CAPILLARY TUBE

410

930

MRA12030

-12008

A S 1 2 0 V D / A S 1 2 1 V D / A S 1 2 4 V D / A S 1 2 5 V D

Indoor unit Outdoor unit

Wall-mounting

12000

1.9

7.8

38 49

10.2

1-200 / 220-50

1180

5.9

90.9

36.0

2 -

250V 10/16A

3.15

-

815x298x182 720x525x245

32.08x11.73x7.17

28.35x20.67x9.65

9.6

31

ø6.35 x 5

ø12.7 x 5

ø17 x 2000

-

-

Rotary

-

1215

Cross-fan

Resin

Propeller

Steel

35 20

2Row 12Step 1Row 20Step

-

CAPILLARY TUBE

410

780

MRA98706

-12008

Samsung Electronics

2-1

2-2 Dimensions

2-2-1 Indoor Unit

Air out

Air in

(Front view)

(Rear view)

2-2-1 Outdoor Unit

(Front view)

2-2

(Remote control)

Installation plate

(Rear view)

Samsung Electronics

2-3 Low pressure & Current Data

Indoor Unit : A S 0 7 0 V E / A S 0 7 1 V E

A S 0 7 4 V E / A S 0 7 5 V E

Outdoor Unit : A X 0 7 0 V E / A X 0 7 1 V E

A X 0 7 4 V E / A X 0 7 5 V E

11

10

9

8

5

4

7

6

3

25 30 35 40 45

Outdoor Inlet air D. B. temp.(°C)

50

11

10

9

8

7

6

5

4

3

14

13

12

25 30 35 40 45

Outdoor Inlet air D. B. temp.(°C)

50

Samsung Electronics

2-3

Product Specifications

Indoor Unit : A S 0 7 0 V D / A S 0 7 1 V D

A S 0 7 4 V D / A S 0 7 5 V D

Outdoor : Unit A X 0 7 0 V D / A X 0 7 1 V D

A X 0 7 4 V D / A X 0 7 5 V D

11

10

9

8

5

4

7

6

3

25 30 35 40 45

Outdoor Inlet air D. B. temp.(°C)

50

11

10

9

8

7

6

5

4

3

14

13

12

25 30 35 40 45

Outdoor Inlet air D. B. temp.(°C)

50

2-4

Samsung Electronics

Product Specifications

Indoor Unit : A S 0 9 0 V E / A S 0 9 1 V E

A S 0 9 4 V E / A S 0 9 5 V E

Outdoor : Unit A X 0 9 0 V D / A X 0 9 1 V E

A X 0 9 4 V D / A X 0 9 5 V E

11

10

9

8

5

4

7

6

3

25 30 35 40 45

Outdoor Inlet air D. B. temp.(°C)

50

11

10

9

8

7

6

5

4

3

14

13

12

25 30 35 40 45

Outdoor Inlet air D. B. temp.(°C)

50

Samsung Electronics

2-5

Product Specifications

Indoor Unit : A S 0 9 0 V D / A S 0 9 1 V D

A S 0 9 4 V D / A S 0 9 5 V D

Outdoor Unit : A X 0 9 0 V D / A X 0 9 1 V D

A X 0 9 4 V D / A X 0 9 5 V D

11

10

9

8

5

4

7

6

3

25 30 35 40 45

Outdoor Inlet air D. B. temp.(°C)

50

11

10

9

8

7

6

5

4

3

14

13

12

25 30 35 40 45

Outdoor Inlet air D. B. temp.(°C)

50

2-6

Samsung Electronics

Product Specifications

Indoor Unit : A S 1 2 0 V E / A S 1 2 1 V E

A S 1 2 4 V E / A S 1 2 5 V E

Outdoor Unit : A X 1 2 0 V E / A X 1 2 1 V E

A X 1 2 4 V E / A X 1 2 5 V E

11

10

9

8

5

4

7

6

3

25 30 35 40 45

Outdoor Inlet air D. B. temp.(°C)

50

11

10

9

8

7

6

5

4

3

14

13

12

25 30 35 40 45

Outdoor Inlet air D. B. temp.(°C)

50

Samsung Electronics

2-7

Product Specifications

Indoor Unit : A S 1 2 0 V D / A S 1 2 1 V D

A S 1 2 4 V D / A S 1 2 5 V D

Outdoor Unit : A X 1 2 0 V D / A X 1 2 1 V D

A X 1 2 4 V D / A X 1 2 5 V D

11

10

9

8

5

4

7

6

3

25 30 35 40 45

Outdoor Inlet air D. B. temp.(°C)

50

11

10

9

8

7

6

5

4

3

14

13

12

25 30 35 40 45

Outdoor Inlet air D. B. temp.(°C)

50

2-8

Samsung Electronics

2-4 Refrigerating Cycle Block Diagram

INDOOR UNIT

T

2-way valve

Capillary tube

Liquid side

OUTDOOR UNIT

Heat exchanger

(Evaporator)

Heat exchanger

(Condenser)

T

Gas side

3-way valve

Compressor

Cooling

Gas leak check point

Samsung Electronics

2-9

M E M O

2-10

Samsung Electronics

4

5

6

7

3. Operating Instructions and Installation

3-1 Operating Instructions

NO

1

2

3-1-1 Name & Function of Key in remote controller

3

NAMED OF KEY FUNCTION OF KEY

On/Off Button. Use this button to start and stop air conditioner.

Temp. up button. If the button is pressed once, the setting temperature is increased by 1°C

Temp. up button. If the button is pressed once, the setting temperature is decreased by 1°C

Each time you press this button,

MODE is changed in the following order.

MODE

(UP)

(DOWN)

8

TURBO

OFF

Use this button to provide heavy duty cooling & Heating for 30 minutes.

Set up the reserve or cancel the timer on and timer off quickly

Use this button for sleep operation.

(The SLEEP mode can be selected at COOL and HEAT mode.)

Adjusts air flow vertically.

Each time you press this button,

BLADE-H rotates by 10.58° (Changable range 42.3°)

Each time you press this button,

FAN SPEED is changed in the following order.

11

12

13

9

10 V

E

C

O

R

ON TIMER

I

T

M

E

R

OFF TIMER

SET

CANCEL

(UP)

14

(DOWN)

15

TIME

Set up the time that operation start.

Set up the time that operation stop.

Use this button to reserve the timer on.

Use this button to reserve or cancel the timer on and timer off.

If the button is pressed once, the time increase by one minute during the time set mode, and ten minutes during the timer set mode.

If the button is pressed once, the time decrease by one minute during the time set mode, and ten minutes during the timer set mode.

Without regard to ON/OFF condition in remote controller, use this button to set current time.

Adjust the current time using button.

(Data can be transmitted after setting up the time)

Samsung Electronics

3-1

Operating Instructions and Installation

3-1-1 Name & Function of Key in remote controller

1. A U TO MODE : In this mode, operation

C O O L mode is selected automatically by the room temperature of initial operation.

Operation Type

Cool Operation

Room Temp

Tr

24.5°C+

T

Tr

24°C+

T

Compressor ON

Compressor OFF

∆ T= -1°, -2°C, 0°C+1°C+2°C

∆ T is controlled by setting temperature up/down key of remote contro l l e r

* FAN SPEED : A U TO

2. C O O L MODE : The unit operates accord i n g to the diff e rence between the setting and room temperature. (18°C~30°C)

3. D RY MODE : Has 3 states, each determined by room temperature .

The unit operates in DRY m o d e .

*Co m p ressor ON/OFF Time is contro l l e d compulsorily(can not set up the fan speed, always bre e z e ) .

* P rotective function : Low temperature release. (Prevention against fre e z e )

4. TURBO MODE : This mode is available in

A U TO, COOL, DRY, FAN MODE.

When this button is pressed at first, the air conditioner is operated “powerful” state for

30 minutes re g a rdless of the set temperat u re, room temperature .

When this button is pressed again, or when the operating time is 30 minutes, turbo operation mode is canceled and returned to the previous mode.

*But, if you press the TURBO button in DRY or FAN mode that is changed with A U TO mode automatically.

5 . S L E E P MODE : Sleep mode is available only in COOL m o d e .

The operation will stop after 6 hours.

*In COOL mode : The setting temperature is automatically raised by 1°C each 1hour

When the temperature has been raised by total of 2°C, that temperature is maint a i n e d .

6. FAN SPEED : Manual (3 step), Auto (4 step)

Fan speed automatically varies depending on both the diff e rence between setting and the room temperature .

3-2

Samsung Electronics

Operating Instructions and Installation

8 . C O M P U L S O RY O P E R ATION :

For operating the air conditioner without the remote contro l l e r.

* A U TO : The operating is the same function that A U TO MODE in the remote cont ro l l e r.

9 .

SWING : BLADE-H is rotated vertically by the stepping motor.

*Memory louver : When ON/OFF button is p ressed at stop state, the BLADE-H re t u r n s to its original location which is operating state before stop

*Swing auto : The BLADE-H can ro t a t e within about 10,500 in the original position set by the SWING SET button.

*Swing Set : Press the button under the remote control is displayed on LCD the , and the blades move up and down, about 43°.

If the one more time press the button, blatles location is stop.

1 0 . Quick OFF TIMER: OFF timer (quick timer) allows reservation or cancel the timer on and timer off quickly

When OFF timer button is pressed at operating state, LCD displays the polling state s e q u e n t i a l l y.

The LCD also displays the time re m a i n i n g .

11 . 24-Hour ON/OFF Real Setting Ti m e r. : The air conditioner is turned ON at a specified

OFF TIMER : The air Conditioner is turned

*ON TIMER : Only timer LED lights on.

*OFF TIMER : Both timer and operation

LED lights on.

*3 minutes delay timer.

1 4 . SELF Diagnosis

LED DISPLAY o p e ra t i o n T I M E R FA N

Tu r b o

Check Point

I n t e r ruption of electric power and Power on.

Abnormal condition of the room sensor.

Abnormal condition of the indoor unit's heat exchanger sensor.

Indoor unit fan motor lock.

:

L E D b l i n k i n g

: LED off

1 5 . TIME SHORTENING : If the "Time short" connector pin is shorted on the main P. C. B, the compressor's three minutes delay function is cancelled, and each operation time is shortened to one fiftieth of its original time.

1 6 . BUZZER SOUND : Whenever the ON/OFF button is pressed or whenever change occurs to the condition which is set up or select, the compulsory operation mode, buzzer is sounded "beep"

Samsung Electronics

3-3

3-2 Installation

3-2-1 Selecting Area for Installation

Select an area for installation that is suitable to the customer's needs.

3-2-1(a) Indoor Unit

1 . Make sure that you install the indoor unit in an area providing good ventilation. It must not be blocked by an obstacle affecting the airflow near the air inlet and the air outlet.

2 . Make sure that you install the indoor unit in an area allowing good air handling and endurance of vibration of the indoor unit.

3. Make sure that you install the indoor unit in an area where there is no source of heat or vapor nearby.

4 . Make sure that you install the indoor unit in an area from which hot or cool air is spre a d evenly in a ro o m .

5 . Make sure that you install the indoor unit in an area away from TVs, audio units, cordless phones, fluorescent lighting fixture s and other electrical appliances (at least 1 m e t e r ) .

6 . Make sure that you install the indoor unit in an area which provides easy pipe connection with the outdoor unit, and easy drainage for condensed water.

7. Make sure that you install the indoor unit in an area which is large enough to accomodate the measurements shown in figure on the next page.

(Fix the unit firmly if it is mounted in a high place.)

3 . Make sure that you install the outdoor unit in area providing good ventilation and which is not dusty. It must not be blocked by any obstacle affecting the airflow near the air inlet and the air outlet.

4 . Make sure that you install the outdoor unit in area free from animals or plants.

5 . Make sure that you install the outdoor unit in area not blocking the traff i c .

6. Make sure that you install the outdoor unit in area easy to drain condensed water fro m the indoor unit.

7. Make sure that you install the outdoor unit in area which provides easy connection within the maximum allowable length of a coolant pipe(15 meters).

Note

1. Add 10 grams of refrigerant (R-22) for every 1 meter if the pipe length exceeds the standard pipe length of 5 meters.

2. Maintain a height between the indoor and outdoor units of less than 3 meters.

8 . Make sure that you install the outdoor unit in an area which is large enough to accommodate the measurements shown in figure on the next page.

3-2-1(b) Outdoor Unit

1 . Make sure that you install the outdoor unit in area not exposed to the rain or direct sun l i g h t .

(Install a separate sunblind if exposed to d i rect sun light.)

2 . Make sure that you install the outdoor unit in area allowing good air moment, not amplifying noise or vibration, especially to avoid disturbing neighbours.

3-2-1(c) Remote Control Unit

1 .

Make sure that you install the remote cont rol unit in an area free from obstacles such as curtains etc, which may block signals f rom the remote control unit.

2. Make sure that you install the remote cont rol unit in an area not exposed to d i rect sunlight, and where there is no sourc e of heat.

3. Make sure that you install the remote cont rol unit in an area away from TVs, audio units, cordless phones, fluorescent lighting f i x t u res and other electrical appliances (at least 1 meter).

Caution :

It is harmful to the air conditioner if it is used in the following environments: greasy areas (including areas near machines), salty areas such as coast areas, areas where sulfuric gas is present such as hot spring areas. Contact your dealer for advice.

3-4

Samsung Electronics

Operating Instructions and Installation

3-2-2 Installation diagram of indoor unit and outdoor unit

A Indoor unit gas leak test check point

Indoor unit

Piping

1

3

2

Tape vinyl

B Drain hose installation

Cut the piping hole sloped slightly

250mm or more

Piping may be laid to the rear, left, right or down .

Right

Rear

Down Rear

200mm or more

Left

5 6

Remote control

Remote control holder

4

10

1

4

5

2

3

Piping (Liquid) 1/4"

7K/9K BTU Piping(Gas)3/8”

12K BTU Piping(Gas)1/2”

Installation tube

Vinyl tape

Putty

Samsung Electronics

8

9

6

7

10

Clamper tube

Installation plate

Pipe-connection

Screw

Drain hose

3-5

Operating Instructions and Installation

3-2-2(a) Fixing the Installation Plate

Installation plate

(Unit : mm)

Pipe hole

(ø65mm)

1. Determine the position of the pipe and drain hose hole using the right figure and drill the hole with an inner diameter of 65mm so that it slants slightly downwards.

2. If you are fixing the indoor unit to a… Then follow Steps…

Wall 3.

Window frame 4 to 6.

3. Fix the installation plate to the wall in a manner appropriate to the weight of the indoor unit.

If you are mounting the plate on a concrete wall with anchor bolts, the anchor bolts must not project by more than 20mm.

280 340

(Unit : mm)

4. Determine the positions of the wooden uprights to be attached to the window frame.

5. Attach the wooden uprights to the window frame in a manner appropriate to the weight of the indoor unit.

6. Using tapped screws, attach the installation plate to the wooden uprights, as illustrated in the last figure opposite.

3-2-2(b) Purging the Unit

On delivery, the indoor unit is loaded with an inert gas.

All this gas must therefore be purged before connecting the assembly piping. To purge the inert gas, proceed as fol lows.

Unscrew the caps at the end of each pipe.

Result : All inert gas escapes from the indoor unit.

• To prevent dirt or foreign objects from getting into the pipes during installation, do NOT remove the caps completely until you are ready to connect the piping.

3-6

Samsung Electronics

Operating Instructions and Installation

3-2-2(c) Connecting the Assembly Cable.

Indoor unit

Outdoor unit

The outdoor unit is powered from the indoor unit via the assembly cable. If the outdoor unit is more than five metres away from the indoor unit, the cable must first be extended to a maximum of ten metre s .

1 . Extend the assembly cable if necessary.

2 . Open the front grille by pulling on the tabs on the lower right and left sides of the indoor unit.

3 . Remove the screw securing the connector cover.

4 . Pass the assembly cable through the rear of the indoor unit and connect the assembly cable to terminals 1, 3, 5.

• Each wire is labelled with the corresponding terminal number.

5 . Pass the other end of the cable through the 65mm hole in the wall.

6 . Replace the connector cover, carefully tightening the scre w.

7 . Close the front grille.

8 . For further details on how to plug the other end of the assembly cable into the outdoor unit, refer to page 3-8.

3-2-2(d) Installing and Connecting the Indoor Unit Drain Hose

C a re must be taken when installing the drain hose for the indoor unit to ensure that any condensa tion water is correctly drained outside.l When passing the drain hose through the 65mm hole drilled in the wall, check that none of the following situations occur.

The hose must

NOT slope upw ards.

The end of the drain hose must NOT be placed in water.

Do NOT bend the hose in different directions.

Keep a clearance of at least 5cm between the end of the hose and the ground.

Do NOT place the end of the drain hose in a hollow.

To install the drain hose, proceed as follows.

1. If necessary, connect the 2-metre extension to the drain hose.

2 . If you are using the extension, insulate the inside part of the extension drain hose with a shield.

3. Pass the drain hose under the refrigerant piping, taking care to keep the drain hose tight.

4. Pass the drain hose through the hole in the wall, making sure that it is sloping downwards, as shown in the illustrations above.

Shield

The hose will be fixed permanently into position once the whole installation has been tested for gas leaks; refer to page 16 for further details.

Drain hose Extension drain hose

Samsung Electronics

3-7

Operating Instructions and Installation

3-2-2(e) Outdoor unit installation

Wiring connection

1. Remove the cover-E parts.

2. Firmly connect the cable connector in the terminal block.

3. Fasten the M4 ring terminal to the hole marked

4. Firmly fix the ass'y cable with clamp wire holder.

5. Assemble the cover-E parts.

6. To prevent the entry of water, form a trap of the ass'y cable as illustrated in the installation diagram of indoor and outdoor unit.

Cover-E parts

Screw

3-8

Samsung Electronics

Operating Instructions and Installation

3-2-2(f) Flare Modification

• Tools used

Flare modification procedure

1 ) Cut the pipe using a pipe cutter.

Oblique Raughness Burr

2 ) Remove burrs at the tip of the pipe cut.

Caution : Burrs not removed may result in leakage of gas.

Pipe

Reamer

3 ) Insert a flare nut into the pipe and modifty flare .

D

A

* Unproper flaring

Outer diameter

ø6.35mm

ø9.52mm

ø12.7mm

A(mm)

1.3

1.8

2.0

Samsung Electronics

Inclined Surface damaged

Cracked Uneven thickness

3-9

Operating Instructions and Installation

3-2-2(g) Air-Purge Procedure

• Use the refrigerant of the outdoor unit to purge air inside indoor unit and pipe.

1. Remove the caps from the 2-way valve(B) and the 3-way valve(A).

2 Turn the 2-way valve cock approx. 45° counterclockwise to open it. Close it about 10 seconds later.

Valve stem

Valve stem

Stopper

3 Check refrigerant leakage of each joint parts

(A, B, C & D in right figure) not leaking

Leaking

If leaking, tighten the flare nut one more time.

If continues to leak, although the pipe fixing area has been tightened again, repair the leaking area.

4. Open the 2-way valve again.

5. Open the service valve cap of the 3-way valve and press the needle valve to discharge gas for 3 seconds and leave it for about 1 minute.

Repeat the above procedure for 3 times to purge air.

Liquid pipe side

Indoor Unit

Gas pipe side

6. Open the 2-way valve and 3-way valve completely

7. Close the cap of each valve.

8. Check each valve for leakage.

3-10

2-way valve

Outdoor Unit

3-way valve

Samsung Electronics

Operating Instructions and Installation

3-2-2(h) Refrigerant Refill

• Refill an air-conditioner with refrigerant when refrigerant has been leaked at installing or using

1. Purge air(for new installation only).

2. Turn the 3-way valve clockwise to close, connect the pressure gauge(low pressure side) to the service valve, and open the 3-way valve again.

3. Connect the tank to refill with Refrigerant

Compound gauge

4. Set the unit to cool operation mode.

5. Check the pressure indicated by the pressure gauge(low pressure side).

* Standard pressure is should be

4.5~5.5kg/cm 2 in a reqular, high operation mode.

For mounting other and of hose when not in use

Suspension hook

High pressure gauge

Hand wheel

Finger tight fittings

Connected to high pressure side

Charging line

6. Open the refrigerant tank and fill with refrigerant until the rated pressure is reached.

* It is recommended not to pour the refrigerant in too quickly, but gradually while operating a pressure valve.

7. Stop operation of the air conditioner.

8. Close the 3-way valve, disconnect the pressure gauge, and open the 3-way valve again.

9. Close the cap of each valve.

Samsung Electronics

3-11

Operating Instructions and Installation

3-2-2(i) Refrigerant Adjustment

Class

Connection

Pipe Length

5m Max.

5~10m

Air-Purge

Method

Refer to the detailed Air-Purge

Procedure

At installation

Refrigerant

Adjustment

Unnecessary

Add 10g of refrigerant

(R-22) for every 1m.

Air-Purge

Method

Purge air using a vaccum pump or an additional refrigerant cylinder.

At service

Refrigerant

Quantity refer to specification sheet

Add 10g of refrigerant

(R-22) for every 1m.

3-2-2(j) Flare unt fixing torque

Outter diameter

ø 6.35 (9000Btu, 12000Btu)

(Liquid Side)

ø 9.52 (9000Btu)

(Gas Side)

ø 12.7 (12000Btu)

(Gas Side)

Torque (kg-cm)

Fixing Torque Final Torque

160 200

300

500

350

550

3-12

Samsung Electronics

Operating Instructions and Installation

3-2-2(k) "Pump down" Procedure

• Pump down' shall be carried out when an evaporator is replaced or when the unit is relocated in another are a .

1. Remove the caps from the 2-way valve and the 3-way valve.

2 Turn the 3-way valve clockwise to close and connect a pressure gauge(low pressure side) to the service valve, and open the 3-way valve again.

3. Set the unit to cool operation mode.

(Check if the compressor is operating.)

2-Way Valve

4. Turn the 2-way valve clockwise to close.

5 When the pressure gauge indicates "0" turn the 3-way valve clockwise to close.

6. Stop operation of the air conditioner.

3-Way Valve

7. Close the cap of each valve.

Relocation of the air conditioner

• Refer to this pro c e d u re when the unit is re l o c a t e d .

1. Carry out the pump down pro c e d u re (r e f e r to the details of 'pump down').

2. Remove the power cord .

3. Disconnect the assembly cable from the indoor and outdoor units.

4. Remove the flare nut connecting the indoor unit and the pipe.

At this time, cover the pipe of the indoor unit and the other pipe using a cap or vinyl plug to avoid foreign material entering.

5. Disconnect the pipe connected to the outdoor u n i t .

At this time, cover the valve of the outdoor unit and the other pipe using a cap or vinyl plug to avoid foreign material entering.

6. Make sure you do not bend the connection pipes in the middle and store together with the cables.

7. Move the indoor and outdoor units to a new l o c a t i o o n .

8. Remove the mounting plate for the indoor unit and move it to a new location.

Samsung Electronics

3-13

M E M O

3-14

Samsung Electronics

4. Disassembly and Reassembly

Stop operation of the air conditioner and remove the power cord before repairing the unit.

4-1 Indoor Unit

No

1

Parts

Front Grille

Procedure

1) Stop the air conditioner operation and block the main power.

2) Seperate tape of front panel upper.

Remark

3) Contract the second finger to the left, and right handle and pull to open the inlet grille.

4) Take the left and right filter out.

* Take the Deadorizing and Electrostatic filter out.

(ONLY “1” and “5” Series models)

5) Loosen one of the right fixing screw and seperate the terminal cover.

6) Loosen two fixing screws of front grille.

Samsung Electronics

7) Pull the upper left and right of discharge softly for the outside cover to be pulled out.

8) Pull softly the lower part of discharge and push it up.

Caution;

Assemble the front panel and fix the hooks of left and right.

4-1

Disassembly and Reassembly

No

2

Parts

Ass’y Tray Drain.

Procedure

1) Do “1”, above.

Separate the drain hose from the extension drain hose.

2) Take the display PCB out.

(Center of indoor unit)

3) Loosen three fixing screws of left and right

4)Pull tray drain out from the back body.

Remark

4-2

3 Electrical Parts

(Main PCB)

1) Do “1”, “2”, above

2) Take all the connector of PCB upper side out.

(Inclusion Power cord)

3) Separate the outdoor unit connection wire from the terminal block.

4) If pulling the Main PCB up. it will be taken out.

(Separate the TRANS hook. it before).

4 Heat Exchanger 1) Do “1” and “2”, “3”, above

2) Loosen two fixing earth screws of right side.

3) Separate the connection pipe.

4) Separate the bush body at the upper side and holder at the rearside.

5) Loosen the two fixing screws of left side.

6) Lifting the heat exchanger up a little to push the up side for separation from the indoor unit.

Samsung Electronics

No

3

Parts

Fan Motor and

Cross Fan

Procedure

1) Do “1” “2” ”3” “4”, above.

2) Loosen the fixing three screws and separate the motor holder.

3) Loosen the fixing screw of fan motor.

(By use of M3 wrench)

4) Separate the fan motor from the fan.

5)Separate the fan from the left holder bearing.

Disassembly and Reassembly

Remark

Samsung Electronics

4-3

Disassembly and Reassembly

4-1 Outdoor Unit

No

1

Parts

Common Work

Procedure

1) Loosen the fixing screw and separate the cover E-parts.

2) Separate the connection wire from the terminal block.

3) Loosen three fixing screws and separate the upper cabinet.

Remark

4) Loosen the two fixing screws of Ass'y E-part.

5) Loosen seven fixing screws and separate the side cabinet.

4-4

2 Fan and Motor

1) Do “1”, above.

2) Loosen two fixing screw, of the front cabinet.

3) Push the brackets of the outer cover to separate the protection mesh from the rear side of front cabinet.

Samsung Electronics

No Parts Procedure

4) Remove the nut flange (Turn to the right to remove, as it is a left hand screw)

5) Separate the fan.

6) Loosen four fixing screws to separate the motor.

Disassembly and Reassembly

Remark

3 Heat Exchanger 1) Do “1”, above.

2) Loosen three fixing screws of left and right side.

3) Disassemble the inlet and outlet pipe by welding.

4) Separate the heat exchanger.

4 Compressor 1) Do “1”, above.

2) Open the terminal cover of compressor and unscrew the connection terminal.

3) Disassemble the inlet and outlet pipe of compressor by welding.

4) Disassemble the inlet and outlet pipe of condenser by welding

5) Loosen the three bolts of the lower part.

6) separate the compressor.

Samsung Electronics

4-5

M E M O

4-6

Samsung Electronics

5. Troubleshooting

5-1 Items to be checked first

1 ) Is the voltage of the power corre c t ?

The input voltage shall be 198-264VAC.

The airconditioner may not operate properly if the voltage is out of this range.

2 ) Is the link cable linking the indoor unit and the outdoor unit linked pro p e r l y ?

The indoor unit and the outdoor unit shall be linked by 5 cables.

Check the terminals if the indoor unit and outdoor unit are properly linked by the same number of cables.

Otherwise the airconditioner may not operate pro p e r l y.

3 ) When a problem occurs due to the contents illustrated in the table below it is a symptom not related to the malfunction of the airc o n d i t i o n e r.

NO Operation of air conditioner

1 The COOL operation indication LED (Green) blinks when a power plug of the indoor unit is plugged in for the first time.

Explanation

It indicates power is on. The LED stops blinking if the operation

ON/OFF button on the remote control unit is pushed.

2 In a COOL operation mode, the compressor does not operate at a room temperature higher than the setting temperature that the IN DOOR FAN should operate.

In a HEAT operation mode, the compressor does not operate at a room temperature lower than the setting temperature that indoor fan should operate.

3 Fan speed setting is not allowed in AUTO or DRY mode.

In happens after a delay of 3 minutes when the compressor is reoperated. The same phenomenon occurs when a power is on.

As a phenomenon that the compressor is reoperated after a delay of

3 minutes, the indoor fan is adjusted automatically with reference to a temperature of the air blew

4 Compressor stops operation intermittently in DRY mode.

The speed of the indoor fan is set to LL in DRY mode.

Fan speed is 5 steps is selected automatically in AUTO mode.

Compressor operation is controlled automatically in DRY mode depending on the room temperature and humidity.

Timer is being activated and the unit is in ready mode.

The unit operates normally if the timer operation is cancelled.

5 Timer LED only of the indoor unit lights up and the air conditioner does not operate.

6 The compressor stops intermittently in a COOL mode or DRY mode, and fan speed of the indoor unit decreases.

The compressor stops intermittently or the fan speed of the indoor unit decreases to prevent inside/outside air frozen depending on the inside/outside air temperature.

4 ) Indoor unit observes operation condition of the air conditioner, and displays self diagnosis details on the display panel.

NO Display

1 Operating LED blinking (1Hz)

2 TIMER LED blinking (1Hz)

3 O P E R ATING and TIMER LED blinking (1Hz)

4 FAN LEA blinking (1Hz)

Self Diagnosis

Restore from power failure (input initial power)

Indoor unit Room sensor Error (open or short)

Indoor unit heat exchanger temperature sensor Error (open or short)

Indoor fan malfunctioning (for spead is Below 38Orpm)

Samsung Electronics

5-1

5-2 Fault Diagnosis by Symptom

5-2-1 No Power (completely dead)-Initial diagnosis

1) Checklist :

(1) Is input voltage normal? (198-264V~)

(2) Is AC power linked corre c t l y ?

(3) Are connections between primary side, secondary side of the power transformer and PCB good.

(4) Is output voltage of DC regulator IC KA7812 (IC01) normal? (11 V D C - 1 2 . 5 V D C )

(5) Is output voltage of DC regulator IC KA7805 (IC02) normal? (4.5VDC-5.5VDC)

2 ) Troubleshooting pro c e d u re

Remove power cord and plug in again in approx. 5 seconds

YES

Replace

PCB display

Is DC voltage of PCB display normal?

NO

Is 198~264VAC applied to the primary side of the power transformer?

NO

•Check linkage between power cord and terminal tap

•Check fuse

NO

Replace power t r a n s f o rm e r

YES

NO

Is 14~18VAC appear in the secondary side of the power transformer?

NO

NO

Is o peration lamp blinking ?

YES

Does operation start when run/stop button on the remote controller unit pushed?

NO

Is transmission display of the remote controller unit blinking?

YES

Is "beep"sound heard from the main unit?

YES

Is DC voltage of the PCB module normal?

YES

Are voltages of #62 (compressor),

#60(4 way valve) and #61 (outdoor fan) of the micom normal? 5VDC

Is voltage of #63 (indoor fan) of the micom normal?

DC5V

YES

NO

NO

YES

10ms

NO

Is voltage at #32 terminal of the Micom normal? 0VDC

Is voltage at #64 terminal of the Micom normal? 5VDC

YES NO

Normal

Refer to remote control unit fault diagnosis

Replace PCB module.

Are voltages at RY71

(Compressor) RY73(4-way valve) and SY72(outdoor fan) normal?

DC12V Is voltage at SS71(indoor fan)

YES

Check connections compressor 4-way valve, outdoor fan and indoor fan.

NO

Replace

RY71,

RY73,

RY72 and

SS71

Is voltage at #25 terminal of the micom normal?

Is output voltage of ICO2 normal?

YES NO

10ms

YES NO

Check PCB pattern .

Replace main PCB.

Replace

ICO2

Is voltage output termina of D101~D105(IN4007) normal?

Are voltage at #30 and #31 of the micom normal?

YES NO

Replace resonator (X501)

100ns

OK

Replace IN4007

Is operation normal?

OK

YES

NO

YES

Replace micom

5-2

Samsung Electronics

Troubleshooting

5-2-2 When the Indoor Unit Fan Does Not Operate. (Initial Diagnosis)

1) Checklist :

(1) Is the indoor unit fan motor properly connected with the connector (CN73)?

(2) Is the AC voltage corre c t ?

(3) Is HALL IC in indoor fan motor properly connected with the connector (CN43)?

(4) Is the running capacitor properly connected with the terminal?

2 ) Troubleshooting pro c e d u re

After unplugging out the power cord should be reconnected within five seconds.

YES

NO

Does the operating lamp(Green) blink?

YES

Does the Solid State Relay(SS71) work properly?

Test rod location

Normal

Voltage

+ -

SS7112V SS71-

YES

NO

Is the supply voltage of the fan motor sufficient?

Test rod location

Normal voltage

PCB CN73 Condition

Fan operate

YES

AC 180V

NO

Samsung Electronics

Check as in the procedur “NO power parts”

PCB is out of order.

Refer tp page 5-2.

Microcomputer is out of order.

MF-C is out of order

Fan motor is out of order.

PCB should be replaced.

Replace MFC

Fan motor should be replaced.

5-3

Troubleshooting

5-2-3 When the Outdoor Unit Does Not Operate. (Initial Diagnosis)

1 ) Checklist :

(1) Is input voltage normal?(198~264VA C )

(2) Is the set temperature of the remote control higher than room temperature in COOL m o d e ?

(3) Is the set temperature of the remote control lower than room temperature in HEAT mode?

(4) Is the POWER IN connector (terminal-tab) linked corre c t l y ?

(5) Is the outdoor unit properly connected with the TERMINAL BLOCK connector(5P)?

2 ) Troubleshooting pro c e d u re

After unplugging out the power cord should be reconnected within five seconds.

NO

Does the operating lamp blink

YES

Does the timer lamp blink during operation ?

NO

YES

Check as in the procedure "No Power parts"

Refer to page 5-2.

Room temperature sensor is out of order

2

PCB should be checked.

Is the power relay RY71 operated by adjusting the room temperature?

NO 1

Test rod location

+ -

IC1 Pin No.63

GND

Condition

RY73 ON

NO

Normal

Voltage

DC 4.8V

YES 3

Microcomputer is out of order.

PCB should be checked.

Is AC 198 - 264V applied relay between Terminal

Tap(TB71) and RY 71 terminal No. 3

YES

Power relay is out of order

1 NO

2 NO

Is the room sensor normal register?

10°C

17.96k

20°C

12.09k

YES 3

30°C

8.3k

Outdoor unit is out of order.

Power relay should be replaced.

5-4

Samsung Electronics

Troubleshooting

5-2-4 When the UP/DOWN Louver Moter Does Not Operate. (Initial Diagnosis)

1) Checklist :

(1) Is input voltage normal? (198-264VA C )

(2) Is the UP/DOWN louver motor properly connected with the connector (CN61)?

2 ) Troubleshooting pro c e d u re

Remove power cord and plug in again in approx. 5 seconds.

Y

Is operating lamp blinking?

Y

Does operation start when swing button of the remote control unit pushed?

N

Voltage at pin #33-#36 of micom (ICO4) change?(Squarewave)

Y

Volatge at pin #10, #11, #12, #13 of IC05 (KID65003) change?(Squarewave)

Y

UP/DOWN louver motor is faulty.

Y

N

N

Check as in the procedure "No

Power parts". Refer to page 5-2.

Normal

Micom (IC04) is faulty.

Driver IC05 (KID65003) is faulty .

5-2-5 In the mode, When there is no warm air current. Check this first;

(1) Is the set temperature of Remote Control lower than room temperature in Heat mode?

(2) Is the Indoor PCB properly connected with the CN71 connector?

After training on, the heating operation should start in five minutes.

NO

Is the munber #60 of Micom (IC04) DC 4.8 V?

YES

Is the munber #15 of IC07 (KID65003) LOW?

YES

Is the voltage between CN71 #3 and RY71 NO 3 AC198~264?

YES

Abnormal 4way valve of Outdoor Unit.

or connecting Cable

4 way valve should be replaced or connecting Cable Check.

YES

NO

NO

NO

Normal

Abnormal Micom

Abnormal IC07

Abnormal RY73

PCB should be replaced.

Samsung Electronics

5-5

Troubleshooting

5-2-6 If Operation By Remote Control Unit Is Impossible. (Initial Diagnosis)

1) Troubleshooting pro c e d u re

Remove power cord and plug in again approx. 5 Seconds

Is operation lamp blinking?

Y

“ “ sound heard from the indoor unit when

ON/OFF button on the remote control unit pushed?

N

Voltage of battery less than 2.5V (Remote Control Unit)?

N

LCD display status of REMOCON normal?

Y

Transmission display lamp ( ) blinking when

ON/OFF button on the remote control unit pushed?

Y

Voltage at PIN #30 of Remocon Micom change?

Y

Voltage at collecter of Q601 or Q602 change?

Y

Y

Y

N

N

N

N

N

Check as in the procedure “NO Power parts”. Refer to page 5-2.

Normal

Replace battery.

LCD is faulty.

Replace button.

Micom is faulty.

Q601(C4375Y) or Q602(C1623Y) is faulty.

IR LED(CL-1L5EU) is faulty.

Voltage at pin #26 of micom (IC04) change (INDOOR UNIT)?

N

Y

Micom (IC04) is faulty.

Receiver module is faulty.

5-6

Samsung Electronics

5-3 PCB Inspection

5-3-1 Cautions for Part Replacement

1 . The human body carries much static e l e c t r i c i t y. Before touching a part for re p a i r, replacement or the similar purpose, be sure to touch a grounded metallic portion by hand to let the static electricity go thro u g h the matallic portion to the earth.

Espectially when handling any micro computer or IC, carefully remove such static electricity before touching them.

2 . When repairing any part on a work bench, be sure to place an insulative sheet on the bench and always keep the sheet surface neat without any metal fragments. If any such fragment touches a part, a secondary t rouble will possibly be caused in the part.

3. B e f o re replacing any parts, be sure to turn o ff the power supply. If such replacement is done with the power supply kept on, an electric shock, short circuit or destruction of a part may re s u l t .

4. During replacement or repair of a part, c a refully handle it : The printed circ u i t b o a rd has fine lead wires (jumper wires) and glass-made parts (diode) on its substrate.

So if a circuit board is roughly handled, such lead wires and parts will be easily broken or damaged by bending or shock.

5 . When soldering the lead wires of any new part, be sure to polish them using an emery paper or the like before solding them.

Since the lead wires of any new part are c o v e red with an oxide film, solder cannot a d h e re to the lead wires if not polished.

6 . When soldering any part, care should be e x e rcised not to apply any high-wattage soldering iron to the part for a long time.

Some parts are of so low a heat re s i s t a n c e that they may be broken or have the p roperties changed if a soldering iron is so applied (Otherwise, the pattern may possibly be separated and raised).

7. The heat of the soldering iron should be t r a n s f e red to the entire object to be soldere d .

If the solder pieces are not well fused due to i n s u fficient transfer of the heat from the soldering iron, no satisfactory electrical continuity can be assured even if the s o l d e red objects appear well connected to each other.

8 . The solder used should be limited to a minimum. If excessive solder is used, it will cause inter-pattern contact, which may cause malfunction of the circ u i t .

5-3-2 Procedure

The parts should be replaced in the following pro c e d u re .

Check for any faulty part.

Detach the faulty part.

Replace it with a new part.

Check the operation of the new part.

The repair is completed.

Samsung Electronics

5-7

Troubleshooting

5-3-3 Detailed Procedure

No.

Malfunction

1 Pull out the power plug from the

AC terminal and confirm the fuse on the PCB assembly

Checking point (symptoms)

1. Is the broken?

2

3

4

5

Causes

1. Voltage over

2. Indoor unit fan motor short-circuit.

Turn the power on.

If lamp blinks trouble is not related to the items 1 through 4 on the right.

Set operating mode when RMC switch pushed.

Except for [FAN]mode and

[TIMER] mode.

Voltage check

1. AC voltage at both end of transformer Primary?

198 - 264V~

2. AC voltage at both end of transformer secondary?

14- 18Vac

2. Transformer is faulty.

3. DC voltage at OUT and GND of IC01

(KA7812)? 12VDC

3. Power circuit is faulty.

4. DC voltage at OUT and GND of IC02? 5VDC

5. DC voltage at Q201 Base and GND change?

squarewave

Voltage check

1. Voltage of relay (RY71) coil Voltage at pin#10, pin#7 of IC07 : 12VDC

1. Irregular power code or power fuse, or poor wiring.

4. Power circuit is faulty.

5. Q201 is faulty.

D101~D104 (IN4007)

1. Relay(RY 71) coil is open.

IC6(ULN2003) is faulty.

2. Relay(RY 71) contactor is faulty.

2. Voltage at Terminal Tap (TB71 or 72) and

RY71 Terminal N0 4 . 198- 264V~

1. Compressor does not operate.

Set operating mode when RMC switch pushed.

1. COOL mode

2. Fan speed [AUTO]

3. Set temperature lower than room temperature

4. Continuously operation.

1. Temperature of Heat exchange is lower.

2. PCB is faulty.

3. Room sensor or Heat exchanger temperature sensor is faulty

Set operating mode when

RMC switch pushed.

1. [FAN] mode

2. Fan speed [Hi]

3. Continuously operation

1. Voltage at 3 5 both ends of CN73 : above 180V~

2. Indoor unit fan motor does not operate.

1. Indoor unit fan motor is faulty.

2. Poor connection of indoor fan motor and connector of RPM sensing (CN43)

5-8

Samsung Electronics

5-4 Fault Diagnosis of Major Parts

Parts

Temp.Sensor

Heat ex. Sensor

Indoor Fan Motor

Diagnosis

Measure resistance with a tester.

Normal 8 K

~27 K

at ambient temperature (+0°C ~ +30°C)

Abnormal

, O

… open or short

Measure resistance between terminals (CN72) with a tester

Normal At ambient temperature (10°C ~ 30°C) between

Red, Yellow

Red, Blue

Resistance

190±10

170±10

Outdoor Fan Motor

Abnormal

Measure the voltage between ground and signal wire of the fan motor

Normal between Voltage

Gray, Orange

Yellow, Orange

05V~4.5V

5V

Abnormal

Normal

Abnormal if voltage does not change from 0V to 5V.

At ambient temperature (10°C ~ 30°C) between

Black, White

Black, Red

Resistance

350±10

270±10

Stepping Motor

(UP/DOWN swing motor)

Abnormal

, O

… open or short

Measure resistance between red wire and each terminal.

Normal Approx. 380

at ambient temperature (20°C ~30°C)

Abnormal

, O

… open or short

Samsung Electronics

5-9

6. Exploded Views and Parts List

6-1 Indoor Unit

6-1

Samsung Electronics

■ Parts List

19

20

21

22

15

16

17

18

No.

6

6-1

6-2

8-1

8-2

9

10

7

7-1

7-2

8

11

12

13

14

1

1-1

4

5

2

3

CODE NO

DB95-20138A

DB66-30153A

DB75-40072A

DB75-40074A

DB75-40076A

DB67-30058C

DB61-40250A

DB31-10078F

DB94-30141A

DB94-40017A

DB93-10472A

DB93-10486A

DB93-10484A

DB32-10008D

DB39-10062V

DB65-40053A

DB61-10136A

DB61-60093A

DB94-20030B

DB61-40219A

DB70-10618A

DB64-10140A

DB64-10143A

DB64-70073A

DB64-70075A

DB63-30131A

DB74-10091A

DB63-10472B

DB92-70075C

DB92-70081A

DB93-10470A

DB93-10475A

DB61-10137A

DB61-10143A

DB41-10199A

DB41-10200A

DB94-10074B

Description

GRILLE AIR INLET

PANEL CENTER DISPLAY

GUARD AIR FILTER

ASS´Y FILTER

COVER TERMINAL

ASS´Y FRONT PANEL

ASS´Y PCB DISPLAY

CASE CENTER PCB

PCB DISPLAY

ASS´Y TRAY DRAIN

ASS´Y STEP MOTOR U/D

BLADE-H

ASS´Y EVAP

SPACER EVAP

ASS´Y HOLDER MOTOR

MOTOR FAN IN

ASS´Y-C-F-FAN

ASS´Y BEARING

ASS´Y MAIN PCB

ASS´Y-THERMISTOR

ASS´Y POWER CORD

ASS´Y TERMINAL BLOCK

CASE CONTROL

BODY-BUSH

ASS´Y BACK BODY

HOLDER PIPE

PLATE HANGER

Exploded Views and Parts List

Specification

ABS

ABS

PC

PC

PP

CLEANER/CARBON

HIPS

ASS´Y

ASS´Y

ASS´Y

ASS´Y

PC

PC

ASS´Y

ASS´Y

ASS´Y

DC12V.600GR

HIPS

ASS´Y

ASS´Y

ASS´Y

PVC

ASS´Y

AMPFS040WTVB

Ø95 619.4mm

ASS´Y

ASS´Y

ASS´Y

ASS´Y

ASS´Y

UCP2

ASS´Y

ABS

HIPS

ASS´Y

HIPS

SGCC-M

AS071VE

AS071VD

1

1

1

1

-

-

1

1

1

1

1

1

1

1

1

1

1

-

-

1

1

-

1

-

1

-

1

-

1

1

1

2

1

-

1

-

1

AS070VE

AS070VD

1

1

1

1

-

-

1

1

1

1

1

1

1

1

1

1

1

-

-

1

1

-

1

-

1

-

1

-

1

1

1

-

2

-

1

-

1

AS075VE

AS075VD

1

1

1

1

-

-

1

1

1

1

1

1

1

1

1

1

1

-

-

1

1

1

1

-

1

-

1

1

-

1

-

2

1

-

1

-

1

AS074VE

AS074VD

1

1

1

1

-

-

1

1

1

1

1

1

1

1

1

1

1

-

-

1

1

1

1

-

1

1

-

1

-

1

-

-

2

1

-

-

1

AS091VE

AS091VD

1

1

-

1

1

-

1

1

1

1

1

1

1

1

1

1

1

-

-

1

1

-

1

-

1

-

1

-

1

1

1

2

1

1

-

-

1

Q’TY

AS094VE

AS094VD

1

1

-

1

-

1

1

1

1

1

1

1

1

1

1

1

1

-

-

1

1

1

1

-

1

-

1

-

1

-

1

-

2

1

-

-

1

AS090VE

AS090VD

1

1

-

1

1

-

1

1

1

1

1

1

1

1

1

1

1

-

-

1

1

-

1

-

1

1

-

1

-

1

1

2

-

-

1

-

1

AS120VE

AS120VD

1

1

1

-

1

-

1

1

1

1

1

1

1

1

1

1

-

1

-

1

1

1

-

1

-

1

-

1

-

1

1

2

-

1

-

-

1

AS095VE

AS095VD

1

1

-

1

-

1

1

1

1

1

1

1

1

1

1

1

1

-

-

1

1

1

1

-

1

-

1

-

1

-

1

2

1

-

1

-

1

AS124VE

AS124VD

1

1

-

1

-

1

1

1

1

1

1

1

1

1

1

-

1

-

1

1

1

1

1

-

1

-

1

-

1

-

1

-

2

-

1

-

1

AS121VE

AS121VD

1

1

1

-

1

-

1

1

1

1

1

1

1

1

1

1

-

1

-

1

1

1

-

1

-

1

-

1

-

1

1

2

1

1

-

1

-

AS125VE

AS125VD

1

1

1

-

-

1

1

1

1

1

1

1

1

1

1

1

-

1

-

1

1

1

1

1

-

1

-

1

-

1

-

2

1

1

-

1

-

Remark

!

!

!

!

!

!

!

!

!

Samsung Electronics

6-2

6-2 Outdoor Unit

6-3

25

25-1

26-1 26-2

Samsung Electronics

■ Parts List

8-5

9

10

11

12

No.

5

6

7

7-1

8

3

4

1

2

13

14

15

16

17

18

19

20

21

22

23

24

25

26-1

26-2

8-1

8-2

8-3

8-4

CODE NO

DB95-10065K

DB95-10065N

DB95-10063B

DB95-10065Q

DB95-10061F

DB73-10004A

DB60-30029A

DB63-20002A

DB63-10165B

DB60-30018A

DB96-10573A

DB62-31668A

DB62-31669A

DB62-31641A

DB96-10579A

DB96-10540A

DB96-10532D

?

?

DB96-10571B

DB96-30181E

?

?

DB72-50563A

DB90-10024D

DB63-10443A

DB39-20388A

DB39-20387A

DB99-90033A

DB99-90033B

DB60-30010A

DB60-30010B

DB60-30010C

2501-001122

2501-001099

2501-001145

2501-001147

2501-001146

DB65-40050A

DB93-50128A

DB47-20001Z

DB47-20002B

DB47-20001Y

DB47-20001V

DB47-20002U

DB47-20001X

DB67-60020A

DB72-50566A

DB72-50558A

DB72-50571A

DB72-50559A

DB72-50557A

DB95-10062Y

DB63-30004A

DB60-30004A

DB67-50063A

DB31-10058C

DB31-10140B

DB90-50009H

DB90-50009J

DB67-30077A

DB94-50032B

DB64-60138A

DB72-50560B

DB91-20076A

DB91-20076B

DB91-20076C

DB91-20076D

DB91-20076E

DB91-20076F

2501-001100

Samsung Electronics

Description

GUARD FAN

NUT FLANGE

PROPELLER-FAN

MOTOR FAN OUT

ASS´Y FRAME

ASS´Y PARTITION

CABINET UPPER

INSU CABI UPPER

ASS´Y-E PARTS.

CAPACITOR

TERMINAL BLOCK

COMP & MOTOR WIRE

O.L.P.

O.L.P SPRING

CLOTH COMP BOTTOM

CLOTH COMP SIDE

CLOTH COMP UPPER

COMPRESSOR

GROMMET-ISOLATOR

NUT-WASHER

GASKET

COVER TERMINAL

NUT-FLANGE

TUBE-DISCHARGE

TUBE-SUCTION

ASSY-CAPI TUBE

ASSY-COND

INSUL CABI-SIDE

ASSY-CABI SIDE

ASSY-COVER E, PARTS

ASSY-CABLE BAG

ASSY-FLARE NUT

FLARE-NUT

Specification

44A070JW1E1

44B092JW1E6

48A124MW1E5

44B092MW1E6

44A070MW1E1

EPDM

HEX 2C MB ZPC

EPDM

NOTYL

M5. SM20C

ASS´Y

ASS´Y

ASS´Y

ASS’Y

ASS´Y

ASS´Y

ASS´Y

ASS’Y

ASS’Y

ASS’Y

ASS’Y

ASS’Y

ASS’Y

FOAMPE+FOAM PU

SECC-P

ASS´Y

RUBBER

VINYL

1/4” + 1/2”

1/4” + 3/8”

1/4”

3/8”

1/2”

ABS

2C SM20C M6 NTR

AS+G/F Ø405

AMASS020WTVA

AMASS015WTVA

ASS´Y

ASS´Y

ASS´Y

ASS´Y

SECC-P

FOAM-PE+FOAM-PU

ASS´Y

ASS´Y

ASS´Y

ASS´Y

ASS´Y

ASS´Y

0.9/30µF 450VAC

1.5/30µF 450VAC

1.5/25µF 450VAC

1.2/30µF 450VAC

1.7/30µF 450VAC

1.7/20µF 450VAC

4P

ASS´Y

MRA12030-12008

MST24AMN-12008

MRA12037-12007

MRA98706-12008

MRA12056-12007

MST24AMM-12008

STS304

FELT

RUB+FELT

FELT

EVA+FO-PU

FELT

48A124JV1E5 and Parts List

AX070VE/AX071VE

AX074VE/AX075VE

1

-

1

1

1

1

1

-

-

1

1

1

-

-

-

1

-

1

1

-

-

-

-

1

1

3

3

1

-

-

1

-

-

1

1

1

-

-

-

1

-

-

-

-

1

1

1

-

-

-

-

1

-

1

-

-

-

-

1

-

1

1

-

-

1

-

1

-

1

1

1

AX070VD/AX071VD

AX074VD/AX075VD

1

-

1

1

1

1

1

-

-

1

1

1

-

-

-

1

-

1

1

-

-

-

-

1

1

3

3

1

-

-

-

-

1

1

1

1

-

-

1

1

-

-

-

-

-

1

1

-

-

-

-

-

1

-

1

-

-

-

1

-

1

1

-

-

1

-

1

-

1

1

1

Q’TY

AX090VD/AX091VD

AX094VD/AX095VD

1

-

1

1

1

-

1

-

1

1

1

1

-

-

1

-

-

-

-

-

-

1

1

1

1

3

3

1

-

-

1

-

-

1

1

1

-

-

-

1

-

1

-

-

-

1

1

-

-

-

1

-

-

-

-

-

-

1

-

-

1

1

1

-

-

1

-

1

1

1

1

AX090VE/AX091VE

AX094VE/AX095VE

1

-

1

1

1

-

1

-

1

1

1

1

-

-

1

-

-

-

-

-

1

-

1

1

1

3

3

1

-

-

-

1

-

1

1

1

-

-

-

1

-

-

-

-

-

1

1

1

-

-

1

-

-

-

-

1

-

-

1

-

1

1

-

-

1

-

1

-

1

1

1

AX120VE/AX121VE

AX124VE/AX125VE

1

1

1

1

-

-

1

1

-

1

1

-

1

-

-

-

-

1

-

1

1

-

-

1

1

3

3

1

-

-

-

-

-

-

1

-

1

-

-

1

-

-

1

-

-

1

1

1

-

-

-

-

-

-

-

-

-

1

1

1

-

1

-

1

-

-

1

1

1

1

1

AX120VD/AX121VD

AX124VD/AX125VD

-

1

1

1

1

-

1

-

1

1

1

-

1

-

1

-

-

-

-

1

1

-

-

1

1

3

3

1

-

-

1

-

-

-

1

-

1

1

-

1

-

1

1

-

-

1

1

-

-

1

-

-

-

-

-

-

-

-

-

1

-

1

1

1

-

-

1

1

1

1

1

Remark

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

!

6-4

6-3 Remote Control & PCB Box

6-3-1 Remote Control

Parts List

No

1

14

15

16

10

11

12

13

8

9

6

7

4

5

2

3

17

6-5

CODE NO

DB93-30052B

DB61-10144A

DB61-10145A

DB64-20054A

DB63-10477A

DB74-10084A

DB73-20110B

DB64-40166B

DB68-10775A

DB68-10777A

PH-M2

DB67-60061A

DB67-60062A

DB67-60063A

90 x 250

DB93-40179B

DB61-40243A

Description

ASS’Y REMOCON

CASE UP

CASE LOW

DOOR REMOCON

COVER BATTERY

FILTER REMOCON

RUBBER REMOCON

INLAY LCD

INLAY REMOCON

LABEL REMOCON

LABEL DOOR

SCREW TAP

SPRING BATTERY

SPRING BATTERY

SPRING BATTERY

PE BAG

ASS’Y PCB REMOCON

HOLDER REMOCON

Specification

ABS

ABS

ABS

ABS

PC

SILICON

PC

PC

ART 90

ART 90

PH-M2

SUS 304

SUS 304

SUS 304

90 x 250

ABS

Q’TY

1

1

1

1

1

1

1

6

1

1

1

1

1

1

1

1

1

Remark

Samsung Electronics

Exploded Views and Parts List

6-3-2 PCB Box

2-3

2-4

2-5

2-6

2-2

2-1

3-1

3

2

1

Parts List

No CODE NO

1

2

2-1

2-2

2-3

2-4

2-5

2-6

3

3-1

DB61-10136A

DB93-10484A

DB93-10486A

DB93-10472A

DB09-10149A

DB32-10008D

DE26-20154A

2306-000294

3501-001058

DE32-10037A

DB93-10470A

DB93-10475A

DB32-50021A

Description Specification

CASE-CONTROL

Ass'y main PCB

Ass'y main PCB

Ass'y main PCB

Micom

Thermistor-EVAP

Trans-power

C-film

Power-relay

Fuse

Ass'y-display and Remocon Module

Ass'y-display and Remocon Module

Module-remocon

-

-

-

MB89635R-466

103AT 240/240

AC230V DC17V 300mA

CFS 99N 450VAC 155K

DI1U DC12V

250V 3.15A

-

TSOP1238UU1

1

1

1

1

1

1

1

Q’TY

7000 9000 12000

1 1 1

1 -

-

-

1

1

-

1

1

1

-

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

Remark

AS070,071 VE/D

090,091 VE/D

120,121 VE/D

AS074,075,094,095

124,125 VE/D

Samsung Electronics

6-6

M E M O

6-7

Samsung Electronics

REMOTE CONTROLLER

POWER ON/OFF

MODE

(AUTO, COOL, DRY,

FAN

TURBO

FAN SPEED SELECT

BLADE-H

MOVING SELECT

ON, OFF TIMER SELECT

TEMPERATURE SELECT

SLEEP SELECT

TIME SETTING

7. Block Diagrams

7-1 Micro Computer Block Diagram

HEAT EXCHANGER SENSOR

ROOM TEMPERATURE SENSOR

INFRARED SIGNAL

RESET

INDOOR CONTROL PANEL

CIRCUIT

OSCILLATION

CIRCUIT

•BLADE-H CONTROL

•INDOOR FAN MOTOR

CONTROL

•COMPRESSOR

CONTROL

• TEMPERATURE

CONTROL

• TIMER

•BUZZER CONTROL

MODE SELECT

SWITCH

TRIGER

SIGNAL

COMPRESSOR CONTROL

SIGNAL

STEPPING MOTOR

CONTROL SIGNAL

BUZZER CONTROL

SIGNAL

SSR

COMPRESSOR DRIVE

STEPPING MOTOR

DRIVE

BUZZER DRIVE

DC 5V DC 12V

VOLTAGE REGULATOR

AC INPUT

DR : 200-220V/50Hz

ER : 220-240V/50HZ

POWER TRANSFORMER

Samsung Electronics

INDOOR FAN MOTOR

SPEED DETECT

ZERO CROSSING

* INDICATOR PANNEL

OPERATION LED

TIMER LED

FAN ONLY LED

INDOOR FAN MOTOR

COMPRESSOR

STEPPING MOTOR

BUZZER

7-1

8. PCB Diagrams

8-1(a) Main PCB-7000Btu(DB93-10484A)

8-1

Samsung Electronics

PCB Diagrams

• PART LIST

No DESIGN LOCATION

HR02

HR03

HR04

LR01

LR02

LR03

LR04

SW02

SW01

OP01

OP02

OP03

OP04

CN41

CN61

CN62

CN71

CN92

TB71,72

RY71

RY72,RY72

J1~J35

HR01

F701

F701

IC01

IC01

IC01

IC02

CR71

FT71

R903,904,905,906

R203

R202,301,409,501~509,513,518~521,601,604,606,902

R522

R523

R405,407

R201,204,405,401,402,404,603,606

R607

R602

R403

R910,912,913

R406,408

D101~105

SS71

BZ61

TN71

TN71

C202,402

C301,401

C102,104,201,203,403,404,501,502,902

C103

C105

C101

C601

IC04

IC03

X501

IC05,IC06,IC07

Q201,401,601,602

Q603

Q902, Q901

SW91

CN73

CN43

35

36

37

38

39

30

31

32

33

34

25

26

27

28

29

20

21

22

23

24

15

16

17

18

19

10

11

12

13

14

5

6

7

8

9

3

4

1

2

55

56

57

58

59

50

51

52

53

54

63

64

65

60

61

62

45

46

47

48

49

40

41

42

43

44

Samsung Electronics

CODE NO Description

DE30-20016A

DE26-20154A

DE60-60012A

2202-000783

2202-000796

2202-000780

2401-000710

2401-001397

2401-000180

2401-001573

DE09-10149A

DE13-20009A

2802-000103

DE13-20024A

A4050-0168

0501-000292

0504-000144

3404-001013

3711-000262

3711-000879

3711-002662

3711-000999

3711-000997

DE32-10037A

DE47-40024A

DE13-20008A

DE62-30032A

DE60-10100A

DE13-10016A

2306-000294

DE29-90004A

2001-000776

2001-000588

2001-000065

DE39-60001A

2001-000065

2001-000036

2001-000042

2001-000855

2001-001088

2001-000890

A1000-0244

2004-001137

0402-000137

B4190-0016

3711-001154

DE59-30001A

3501-001058

B3068-0092

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

R-METAL FILM

DIODE-RECT

THYRISTOR

BUZZER

TRANS L.V

PIN EYELET

C-CERAMIC

C-CERAMIC

C-CERAMIC

C-ELEC

C-ELEC

C-ELEC

C-ELEC

IC-MCU

IC

RSONATOR-CERAMIC

IC-DRIVE

TR-GENERAL

TRANSISTOR

TRANSISTOR

FUSE

HOLDER-FUSE

IC-VOLT REGU

HEAT-SINK

SCREW-PH

IC-VOLT REGU

C-FILM

FILTER NOISE

R-CARBON

R-CARBON

R-CARBON

WIRE SO COPER

R-CARBON

R-CARBON

R-CARBON

R-CARBON

R-CARBON

R-CARBON

R-CARBON

SWITCH-TACT

CONNECTOR WAFER

CONNECTOR WAFER

CONNECTOR WAFER

CONNECTOR WAFER

CONNECTOR WAFER

CONNECTOR WAFER

CONNECTOR WAFER

CONNECTOR-TERMINAL

RELAY

RELAY

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

Specification

RD 1/4 TP 682-F

1N4007

G3MB-202PL

CBE 2220BA STICK

230V DC17V 300mA

OD2.5 L3.0

CA OA 50V 103Z

CA OA 50V 102Z

CA OA 50V 104Z

CE04 25V 222-M

CE 04 25V 471-M

CE 04 35V 102-M

47/50V

MB89635R-466

KA7533Z

10MHz

KID65003AP

KSC945Y

A708Y

R2002

FST 250V 3.15A

FH-51H 7.5A

KA7812A

AL H25

M3*6 FeFzY

KA7805A

CQS 450V 1.5

MD250V 1.6A 6mH

RD 1/2 T(S) 821-J

RD 1/4 TP 332-J

RD 1/4 TP 103-J

P10.6 SN T 52MM

RD 1/4 TP 103-J

RD 1/4 TP 331-J

RD 1/4 TP 102-J

RD 1/4 TP 560-J

RD 1/2 TP 102-J

RD 1/4 TP 682-J

RD 1/8 TP 332-J

KPT-1115V

YW396-05AV WHT

SMW250-03 BLU

JSW250-02WHT

SMW250-05 WHT

SMW250-05BLU

YW396-03AV BLK

SMW250-09 WHT

250TAP, 1PIN

DI1U DC12V

JQ1a-12V

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

AS070VE/D

AS071VE/D

AS074VE/D

AS075VE/D

B

1

1

1

1

1

1

1

1

3

4

9

1

1

1

1

1

1

5

2

2

1

3

2

5

1

1

2

8

1

1

21

1

1

4

1

1

1

1

1

1

1

1

0

1

0

1

0

1

0

0

1

1

1

0

1

35

1

2

1

0

1

1

1

0

1

ASH070VE/D

ASH071VE/D

ASH074VE/D

ASH075VE/D

C

1

2

1

1

1

1

1

1

3

4

9

1

1

1

1

1

1

5

2

2

1

3

2

5

1

1

2

8

1

1

21

1

1

4

1

1

1

1

1

1

1

1

0

1

1

0

0

0

1

0

1

1

1

0

1

2

1

2

35

1

1

1

1

1

1

AS070VB

AS071VB

AS074VB

AS075VB

A

1

1

1

1

1

1

1

1

3

4

9

1

1

1

1

1

1

5

2

2

1

3

2

5

1

1

2

8

1

1

1

4

1

21

1

1

1

1

1

1

1

1

1

0

0

1

1

0

0

0

0

1

1

1

1

2

1

0

35

0

1

1

1

0

1

8-2

8-1(b) Main PCB-9000Btu(DB93-10486A)

12000Btu(DB93-10482A)

8-3

Samsung Electronics

PCB Diagrams

• PART LIST

No DESIGN LOCATION

HR02

HR03

HR04

LR01

LR02

LR03

LR04

SW02

SW01

OP01

OP02

OP03

OP04

CN41

CN61

CN62

CN71

CN92

TB71,72

RY71

RY72,RY72

J1~J35

HR01

F701

F701

IC01

IC01

IC01

IC02

CR71

FT71

R903,904,905,906

R203

R202,301,409,501~509,513,518~521,601,604,606,902

R522

R523

R405,407

R201,204,405,401,402,404,603,606

R607

R602

R403

R910,912,913

R406,408

D101~105

SS71

BZ61

TN71

TN71

C202,402

C301,401

C102,104,201,203,403,404,501,502,902

C103

C105

C101

C601

IC04

IC03

X501

IC05,IC06,IC07

Q201,401,601,602

Q603

Q902, Q901

SW91

CN73

CN43

38

39

40

41

42

33

34

35

36

37

28

29

30

31

32

23

24

25

26

27

18

19

20

21

22

13

14

15

16

17

8

9

10

11

12

3

4

5

1

2

6

7

58

59

60

61

62

63

64

65

53

54

55

56

57

48

49

50

51

52

43

44

45

46

47

Samsung Electronics

Description

R-METAL FILM

DIODE-RECT

THYRISTOR

BUZZER

TRANS L.V

PIN EYELET

C-CERAMIC

C-CERAMIC

C-CERAMIC

C-ELEC

C-ELEC

C-ELEC

C-ELEC

IC-MCU

IC

RSONATOR-CERAMIC

IC-DRIVE

TR-GENERAL

TRANSISTOR

TRANSISTOR

FUSE

HOLDER-FUSE

IC-VOLT REGU

HEAT-SINK

SCREW-PH

IC-VOLT REGU

C-FILM

FILTER NOISE

R-CARBON

R-CARBON

R-CARBON

R-CARBON

R-CARBON

R-CARBON

R-CARBON

R-CARBON

R-CARBON

R-CARBON

R-CARBON

SWITCH-TACT

CONNECTOR WAFER

CONNECTOR WAFER

CONNECTOR WAFER

CONNECTOR WAFER

CONNECTOR WAFER

CONNECTOR WAFER

CONNECTOR WAFER

CONNECTOR-TERMINAL

RELAY

RELAY

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

WIRE SO COPER

CODE NO

DE30-20016A

DE26-20154A

DE60-60012A

2202-000783

2202-000796

2202-000780

2401-000710

2401-001397

2401-000180

2401-001573

DE09-10149A

DE13-20009A

2802-000103

DE13-20024A

A4050-0168

0501-000292

0504-000144

3404-001013

3711-000262

3711-000879

3711-002662

3711-000999

3711-000997

DE32-10037A

DE47-40024A

DE13-20008A

DE62-30032A

DE60-10100A

DE13-10016A

2306-000294

DE29-90004A

2001-000776

2001-000588

2001-000065

2001-000065

2001-000065

2001-000036

2001-000042

2001-000855

2001-001088

2001-000890

A1000-0224

2004-001137

0402-000137

B4190-0016

3711-001154

DE59-30001A

3501-001058

B3068-0092

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

DE39-60001A

Specification

CBE 2220BA STICK

230V DC17V 300mA

OD2.5 L3.0

CA OA 50V 103Z

CA OA 50V 102Z

CA OA 50V 104Z

CE04 25V 222-M

CE 04 25V 471-M

CE 04 35V 102-M

47/50V

MB89635R-466

KA7533Z

10MHz

KID65003AP

KSC945Y

A708Y

R2002

KPT-1115V

YW396-05AV WHT

SMW250-03 BLU

FST 250V 3.15A

FH-51H 7.5A

KA7812A

AL H25

M3*6 FeFzY

KA7805A

CQS 450V 1.5

MD250V 1.6A 6mH

RD 1/2 T(S) 821-J

RD 1/4 TP 332-J

RD 1/4 TP 103-J

RD 1/4 TP 103-J

RD 1/4 TP 103-J

RD 1/4 TP 331-J

RD 1/4 TP 102-J

RD 1/4 TP 560-J

RD 1/2 TP 102-J

RD 1/4 TP 682-J

RD 1/8 TP 332-J

RD 1/4 TP 682-F

1N4007

G3MB-202PL

JSW250-02WHT

SMW250-05 WHT

SMW250-05BLU

YW396-03AV BLK

SMW250-09 WHT

250TAP, 1PIN

DI1U DB12V

JQ1a-12V

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

PI0.6 SN T 52MM

A/S

1

1

1

1

1

1

1

1

3

4

9

1

1

1

1

1

1

5

2

2

1

3

2

5

1

0

2

8

1

1

21

0

1

4

1

1

1

1

1

1

1

1

0

0

1

0

0

1

0

1

0

1

1

0

35

0

2

1

0

1

1

1

0

1

A S 0 9 0 V E / D

A S 0 9 1 V E / D

A S 0 9 4 V E / D

A S 0 9 5 V E / D

A

1

1

1

1

1

1

1

1

1

3

4

9

1

1

1

1

1

1

5

2

2

1

3

2

5

1

0

2

8

1

1

21

0

1

4

1

1

1

1

1

1

1

1

0

0

1

0

0

0

1

0

0

1

0

0

35

1

2

1

0

1

1

1

0

1

A S 1 2 0 V E / D

A S 1 2 1 V E / D

A S 1 2 4 V E / D

A S 1 2 5 V E / D

B

1

A S H 1 2 0 V E / D

A S H 1 2 1 V E / D

A S H 1 2 4 V E / D

A S H 1 2 5 V E / D

D

1

1

2

1

1

1

1

1

1

3

4

9

1

1

1

1

1

1

5

2

2

1

3

2

5

1

1

2

8

1

1

1

4

1

1

1

21

1

1

1

1

1

1

0

1

0

0

1

0

0

0

0

1

0

0

2

1

2

35

1

1

1

1

1

1

A S H 0 9 0 V E / D

A S H 0 9 1 V E / D

A S H 0 9 4 V E / D

A S H 0 9 5 V E / D

C

1

1

2

1

1

1

1

1

1

3

4

9

1

1

1

1

1

1

5

2

2

1

3

2

5

1

1

2

8

1

1

21

1

1

4

1

1

1

1

1

1

1

1

0

1

0

1

0

0

0

1

0

1

1

0

35

0

2

1

2

1

1

1

1

1

8-4

8-2 ASS’Y DISPLAY & Module

•DB93-10470A : AS070,071,090,091,120,121VE/D

•DB93-10475A : AS074,075,094,095,124,125VE/D

• PCB-DISPLAY (AS070,071,090,091,120,121VE/D) : DB41-10199A

• PCB-DISPLAY (AS074,075,094,095,124,125VE/D) : DB41-10200A

L

M

J

K

N

G

H

I

• PART UST

No

C

D

E

F

A

B

Description

LED - LAMP

LED - LAMP

LED - LAMP

LED - LAMP

CONNECTOR WAFER

PCB-DISPLAY

MODULE REMOCON

C/W DIS & MODULE

CASE-CENTER PCB

PAINT

C-CERAMIC

C-CERAMIC

DIOD-SWITCHING

R-CARBON

8-5

CODE-NO

DB07-10022A

0601-001059

0601-001060

0601-001196

DB41-10200A

DB41-10199A

DB32-50021A

DB39-20346A

DB61-10143A

DB61-10137A

2202-000780

2201-000283

0401-000005

2001-000034

Specification

LTL-52EG-002(ORG/GRN)

SY5511 (YEL)

SM5511 (GRN)

SO5511 (ORG)

YWLA200-09P

FR-1T1.6 W20L170

FR-1T1.6 W20L170

TSOP-1238UU1

-

AS074,075,094,095,124,125VE/D

AS070,071,090,091,120,121VE/D

DCR200H(BROWN)

CA OA 50V 104Z

CA OA 50V 102Z

1N4148

RD 1/4TP 221-J

Q’TY

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

Samsung Electronics

9. Wiring Diagrams

9-1 Indoor Unit

Samsung Electronics

9-1

9-2 Outdoor Unit

• AX120/121/124/125VE • AX120/121/124/125VD

CAPACITOR AX120/121/124/125VE: 0.9/30µF X 450VAC

• AX070/071/074/075VE

CAPACITOR AX120/121/124/125VD: 1.2/30µF X 450VAC

• AX070/071/074/075VD

CAPACITOR AX070/071/074/075VE: 1.5/25µF X 450VAC

• AX090/091/094/095VE

CAPACITOR AX070/071/074/075VD: 1.7/20µF X 450VAC

• AX090/091/094/095VD

9-2

CAPACITOR AX090/091/094/095VE: 1.5/30µF X 450VAC CAPACITOR AX090/091/094/095VD: 1.7/30µF X 450VAC

Samsung Electronics

M E M O

Samsung Electronics

9-3

M E M O

9-4

Samsung Electronics

10. Schematic Diagrams

10-1 Indoor Unit

Samsung Electronics

10-1

10-2 Remote Control

Samsung Electronics

10-2

Application date Page

U P D A TE LOG SHEET

Part# Note(Cause & Solution) S/Bulletin#

Use this page to keep any special servicing information. (Service Bulletin, etc.)

If only parts number changes, Just change parts number directly on parts list.

And if you need more information, please see the service bulletin

Copyright

®œ 1995 by Samsung Electronics Co., Ltd.

All rights reserved.

This manual may not, in whole or in part, be copied, photocopied, reproduced, translated, or converted to any electronic or machine readable from without prior written permission of

Samsung Electronics Co., Ltd.

SyncMaster 17GLi/CMG7387L Service Manual

First edition June 1995.

Printed in Korea.

Tr a d e m a r k s

Samsung is a registered trademark and

SyncMaster 17GLi/CMG7387L and

MacMaster

Cable Adapter are trademark of Samsung

Electronics Co., Ltd.

Macintosh, Centris, Quadra, Duo Dock, and

Power Macintosh are trademark of Apple computer, Inc.

All other trademarks are the property of their respective owners.

advertisement

Related manuals

advertisement