Interalia XMU + announcement and call processing system Installation and Maintenance Guide
The XMU+ is a modular voice announcement and call processing system designed for a variety of applications, including ACD/UCD, Interactive Auto Attendant, DTMF Call Processing, and Music On Hold. The XMU+ can be remotely managed through a modem or Ethernet connection using the XMUCOM+ software. The XMU+ comes in two sizes, a large chassis with up to 64 analog channels, 48 T1 channels, and 6 hours of recording time, and a small chassis with up to 8 analog channels, 24 T1 channels, and 6 hours of recording time.
Advertisement
Advertisement
Installation & Maintenance Guide
Copyrights
This manual and the software accompanying it are copyrighted © 2009-2011 by Interalia Inc. ®
XMU+ Installation and Maintenance Guide
MA18500R07E7.5
All rights reserved. No part of this book, including interior design, cover design, and icons, may be reproduced or transmitted in any form, by any means (electronic, photocopying, recording, or otherwise) without the prior written permission of Interalia Inc.
Interalia Inc.
Marketing Department
4110 - 79th Street N.W.
Calgary, Alberta, Canada T3B 5C2
Phone: (403) 288-2706
Fax: (403) 288-5935
Interalia and the publisher have used their best efforts in preparing this book as accurately and completely as possible, however we do not make any guarantees or warranties regarding its content.
Trademarks
Interalia is a registered trademark of Interalia Inc.
XMU+ is a registered trademark of Interalia Inc.
All other product names and services identified throughout this book are used in an editorial fashion only, and for the benefit of such companies. No such use, or the use of any trade name, is intended to convey endorsement or other affiliation with the book.
XMU+ Installation and Maintenance Guide rev.07
i
Note: For the latest revision of this guide please go to http://www.interalia.com/Support/Manuals
Table of Contents
Chapter 1: Introducing XMU+
About the XMU+ Announcement and Call Processing System.......................................3
Chapter 2: Before You Start
Chapter 3: Delivery Checklist
Chapter 4: Applying Hardware Settings to XMU+ Line Cards
ii Table of Contents
Chapter 5: Installing the XMU+
Chapter 6: Cabling the XMU+
PBX Interface Table Conventions and Abbreviations ............................................... 42
Connecting the XMU+ to a PC with XMUCOM+ Software ...................................... 48
To connect to the PC with an analog line to modem ........................................ 49
To connect to the PC through an Ethernet (LAN) Network ............................. 50
To connect to the PC directly with the Network port ........................................ 50
To connect an analog line to provide Remote Telephone Access ................ 51
XMU+ Installation and Maintenance Guide rev.07
iii
GPT iSDX and Realitis; Siemens 9005-9006, HiPath 3000,
HiPath 4000; Intecom; ITT 3100; HICOM 300 Series;
Mitel SX50, SX200, SX2000, 3300; Toshiba Perception Rolm 9751,
Nortel SL-1®or Meridian-1® (option 1), DMS-100,
Northern Telecom SL-1®or Meridian-1® (option 2) ............................................. 64
Level Start/Pulse Return - Multiple Play (LS/PR-MP) ........................................... 69
Chapter 7: Understanding XMU+ Navigation
iv Table of Contents
Message Menu Hierarchy - Single Partition Mode .............................................. 77
Node Menu Hierarchy - Single Partition Mode ..................................................... 78
System Menu Hierarchy - Single Partition Mode ................................................. 78
Card Menu Hierarchy - Multiple Partition Mode .................................................. 79
System Menu Hierarchy - Multiple Partition Mode ............................................. 80
Partition Menu Hierarchy - Multiple Partition Mode .......................................... 80
When XMU+ is operating in Single Partition mode: ........................................... 85
When XMU+ is operating in Multiple Partition mode: ....................................... 85
Setting Up XMU+ Remote Telephone Access (optional) ......................................... 86
To set XMU+ Remote Telephone Access mode .................................................... 86
To change the default Remote Telephone Access code ................................... 87
Working with Remote Telephone Access Messages ................................................. 90
To change default language of operation (optional) ......................................... 92
Chapter 8: Testing XMU+ Installation
XMU+ Installation and Maintenance Guide rev.07
v
To assign messages to a line (from the Front Panel) ........................................100
Chapter 9: XMU+ Hardware Upgrades
To remove a secondary Power Supply card .........................................................115
Chapter 10: Troubleshooting XMU+ Installation
vi Table of Contents
To check for XMU+ power supply failures - Small Chassis .............................128
To check for XMU+ power supply failures - Large Chassis .............................128
To select a previous firmware (APP Image) version ..........................................131
To reset unit to default factory settings (including flash memory) .............132
Chapter 11: XMU+ Technical Specifications and Approvals
Glossary
Index
End User License Agreement
Introducing XMU
+
Read this chapter to gain an understanding of the XMU+ product and of how this installation guide can help you install the XMU+ unit quickly and safely.
In this chapter....
About the XMU+ Announcement and Call Processing System on page 3.
About XMUCOM+ Software on page 3.
1
2 Chapter 1
Introducing XMU+
ACD
Automatic Call
Distribution
UCD
Uniform Call
Distribution
XMU+ Installation and Maintenance Guide rev.07
About the XMU+ Announcement and Call Processing System
3
About the XMU
+
Announcement and Call
Processing System
The XMU+ Digital Call Processor is a voice announcement and call processing system.
Modular in design and field upgradable, the XMU+ offers major advantages in processing customer calls for a broad range of customer needs. The XMU+ delivers:
High quality ACD/UCD announcements.
Interactive auto-attendant functionality.
Pre-recorded messages that play to assigned lines when the unit is activated by an incoming call.
Ability for users to navigate through different levels of messages by entering commands with a touch-tone telephone.
Flash memory that ensures configurations, statistics and messages are not lost in the event of power failures.
High-speed Ethernet connection for fast downloading of system configuration and message files.
Internal modem.
Who Uses XMU
+
XMU+ is used by a broad range of industries for a variety of functions such as:
Passive announcements.
Interactive announcements.
Music on hold.
Public announcements.
Interactive auto attendants.
Call processing and transferring.
See Typical Uses for XMU+ on page 7 for more information about each of the above
functions.
About XMUCOM
+
Software
The XMUCOM+ software is a Windows-based application that lets you program, download, update, and back up configurations and messages to the XMU+ from a PC.
The intuitive XMUCOM+ interface displays configuration outlines and detailed node information. See XMU+ QuickStart Guide for more information.
Configurations designed with XMUCOM+ are transmitted to the XMU+ unit through a modem connection, or an Ethernet (LAN-based network or direct) connection. See
Connecting the XMU+ to a PC with XMUCOM+ Software on page 48 for more
information.
4 Chapter 1
Introducing XMU+
Product Overview
XMU+ units are compatible with all major telephone systems and can be remotely managed through a modem or Ethernet connection that uses XMUCOM+ (see
XMUCOM+ Software on page 3 for more information).
XMU+ is available in two sizes:
Large Chassis.
Small Chassis.
XMU+ Large Chassis
The XMU+ large chassis provides state-of-the-art design, flexible configuration options for users requiring up to:
64 analog channels.
48 T1 channels.
6 hours of recording time for music and messages.
The XMU+ large chassis handles up to 8 line cards for call processing, audiotext, ACD announcements, and auto attendant. With a Music-On-
Hold card installed, it can also act as a music/messaging on-hold system with two music inputs and four different outputs.
XMU+ Small Chassis
The XMU+ small chassis provides an effective solution for users requiring only one line card.
The XMU+ small chassis provides up to:
8 analog channels.
24 T1 channels.
XMU+ Installation and Maintenance Guide rev.07
Product Overview
5
Line Cards Supported by XMU
+
Depending on the chassis size, the XMU+ can support several different line cards. As well, each line card may have several variants, depending on the number of ports required and the country of
use. See XMU+ Approvals on page 143 for more
information about XMU+ approving bodies for the countries in which XMU+ is used.
Visit the Interalia website at www.interalia.com for more information about each line card.
This Line
Card...
Lets the XMU+...
Part Numbers
Number of ports
Low
Impedance
MWR (Mini
Weather
Radio)
Provide ACD/UCD messages just like a
Hybrid Analog line card, however it can connect one (1) passive line to up to twenty-four (24) PBX trunks.
For use with a
Nortel PBX:
47220
47260
Broadcast weather information for
Environment Canada (available only in
Canada).
47366 8
47363
47365
4
8
4
8
Hybrid Analog Provide Auto Attendant/Audiotex announcements,
1-800 ACD call routing, and ACD/UCD intercept messages.
Hybrid Analog line cards replace the
Passive and Interactive Line Cards by combining their features.
For use with a
Siemens PBX:
47672
47670
T1
4
8
24 Connect to a T1 communication link to provide 24 T1 user channels.
47367
The T1 card provides support for industry standard digital communication interfaces.
6 Chapter 1
Introducing XMU+
This Line
Card...
MOH (Music
On Hold)
Lets the XMU+...
Part Numbers
Combine music (from an existing source) and messages to create an “On
Hold” environment.
47804
Number of ports
4 output,
2 input
XMU+ Installation and Maintenance Guide rev.07
Product Overview
7
Typical Uses for XMU
+
The XMU+ can be used for several different purposes, depending on the chassis size and selected combination of line cards. See
Product Overview on page 4 and
Cards Supported by XMU+ on page 5 for more information.
XMU+ is used as a...
Passive Announcer
In this manner...
An XMU+ equipped with a Hybrid Analog or Low
Impedance line card can be used as a Passive
Announcement System. Typical uses include:
ACD/UCD customized announcements.
Day of week announcement.
Time of day announcements.
Date specific announcements.
Interactive Auto Attendant An XMU+ equipped with a Hybrid Analog or T1 line card can be used as an Interactive Auto Attendant
System.
Typical uses include:
Audiotex/Information lines providing automated messages to callers. An extremely flexible system, the XMU+ can be configured to play different messages depending on:
Time of day.
Day of week.
Date and selections made by a caller.
Interactive Auto attendants such as:
Press 1 for Sales, Press 2 for Technical
Support.
Please enter the extension of the person you wish to speak to.
8 Chapter 1
Introducing XMU+
DTMF
Dual Tone
Multi Frequency
XMU+ is used as a...
DTMF Call Processing
Music On Hold Player
In this manner...
An XMU+ equipped with a Hybrid Analog or T1 line card can be used as a DTMF Call Processing system.
Typical uses include Call Center routing with either front ending or back ending ACD queues:
In front-ending ACD queues, XMU+ answers all incoming calls, presents a menu, and transfers the call to the appropriate queue.
In back-ending ACD queues, the client’s telephone system answers the call and places the user in the queue. XMU+ plays the appropriate holding messages, and transfers the caller to the requested person when the line becomes available.
An XMU+ equipped with a Music On Hold (MOH) line card can be set up to combine music and messages to create an “On Hold” environment for your callers.
The music source (such as a radio or CD) can be:
Stored in and played from a solid state medium on the Control card’s flash memory.
Played directly to the MOH from an external audio feed.
Routed through the MOH audio directly to the PBX.
Each MOH system provides up to six hours of recording time. Messages can be recorded from four sources:
Telephone handset.
Tape unit.
Remote access using a touch tone telephone.
WAV files that are downloaded using a PC.
XMU+ Installation and Maintenance Guide rev.07
In this book
9
In this book
This guide helps you to install the XMU+ unit and perform basic maintenance and upgrade procedures.
Read this chapter...
To understand...
The XMU+ product and how it can be used to address the needs of your organization.
The prerequisites for installing the
XMU+ unit and the installation procedure you must follow.
The information you need to provide to others once you have completed the XMU+ installation.
How to apply settings to the line cards that accompany your XMU+.
How to install the XMU+ unit and connect it to its power supply.
How to connect and wire the XMU+.
How to configure the XMU+ from the
Front Panel or through remote telephone access.
How to test XMU+ communication with the PBX and with XMUCOM+ software.
How to perform basic XMU+ maintenance procedures, as well as specific upgrades.
Typical errors that users encounter during installation and maintenance, and how to resolve these errors.
XMU+
Installation
Process Flow
Understand XMU+
Features
Before
You Start
Delivery
Checklist
Apply Line
Card Settings
Install
XMU+
Connect and
Wire XMU+
Understand XMU+
Navigation
Test XMU+
Setup
Upgrade
XMU+
Troubleshoot
XMU+
XMU+ Technical
Specifications
10 Chapter 1
Introducing XMU+
Read this chapter...
To understand...
Technical Specifications and Approvals
Additional technical information about the XMU+ unit and accessories.
Industry standard terminology used in XMU+ documentation.
An alphabetic list of all the activities and concepts documented in this guide.
Before You Start
Because of its ability to adapt to a variety of situations, the technical features of the XMU+ unit ordered by your company are unique. Before you start to install the XMU+ unit, you should:
Unpack the XMU+ unit, using the checklists provided, to ensure that all required components are available.
Identify the features of your particular XMU+ unit.
Understand the general requirements of the XMU+ unit, including environmental, power connection, and PBX requirements.
In this chapter...
Before You Start Activities on page 13.
Line Card Checklist on page 14.
Meeting System Requirements on page 16.
Environmental Requirements on page 16.
Power Requirements on page 17.
2
12 Chapter 2
Before You Start
XMU+ Installation and Maintenance Guide rev.07
13
Before You Start Activities
1.
2.
3.
Before You Start Activities
Complete the following activities before you start to install the XMU+:
Before You Start
Unpack
XMU+
Understand
XMU+ Features
Meet System
Requirements
Environmental
Power
PBX
Unpack the XMU+ and its hardware accessories.
Identify the features unique to your XMU+. See XMU+ Features on page 15 for
more information.
Ensure all requirements are met for XMU+ installation. These requirements include:
Environmental requirements. See
Environmental Requirements on page 16
for more information.
Power requirements. See
Power Requirements on page 17 for more
information.
PBX requirements. See
PBX Requirements on page 17 for more
information.
14 Chapter 2
Before You Start
Hybrid Analog
Line Card Checklist
The call processing features of the XMU+ can be made even more flexible and userspecific with the addition of one or more line cards.
Use the following checklist to ensure that all line cards ordered for the XMU+ have been pre-installed in the XMU+, and to record the slot numbers in which they are installed. Record this information in the Delivery Checklist, as well.
MOH
MWR
There can be more than one of a particular type of line card installed, depending on the planned functionality of this XMU+.
Hybrid Analog
MOH
MWR
T1
Part #: __________________ Slot #: ______________
Part #: __________________ Slot #: ______________
Part #: __________________ Slot #: ______________
Part #: __________________ Slot #: ______________
Low Impedance.
Part #: __________________ Slot #: ______________
T1
Low Impedance
See Line Cards Supported by XMU+ on page 5 and
Cabling XMU+ Line Cards on page
54 for more information about individual line cards and part numbers.
XMU+ Installation and Maintenance Guide rev.07
15
XMU+ Features
XMU+ Features
The XMU+ is a microprocessor-based voice announcement and call processing system. It is modular in design, field upgradeable, and available in two sizes. Systems interface with XMU+ through the ports and cards installed on the rear panel, while users interface with XMU+:
Through its Front Panel (see
Understanding the XMU+ Front Panel on page 81).
Remotely via telephone (see
Using Remote Telephone Access on page 88).
With XMUCOM+ software (see About XMUCOM+ Software on page 3).
See XMU+ Technical Specifications and Approvals on page 135 for more detailed
information about XMU+’s technical specifications.
Front Panel
Both the small and large XMU+ chassis provide the same Front Panel features:
Small Chassis
Large Chassis
Feature...
Function...
2 x 16 Character
Display
Function (Arrow)
Keys
The LCD shows function information and line status to the operator/programmer.
Four buttons for selecting and configuring XMU+ functions.
Handset Input/Output A port to connect a handset to record or play back messages.
Recording Source
Input/Output
A port to connect a recording source (such as a tape deck) to record messages.
16 Chapter 2
Before You Start
Meeting System Requirements
Before you begin to install the XMU+ unit, you need to ensure that XMU+ system requirements are met. These requirements include:
Environmental Requirements on page 16.
Power Requirements on page 17.
Environmental Requirements
HVAC
Heating, Venting, and Air Conditioning.
For optimum operation of the XMU+ unit, ensure that the XMU+ is placed in an environment that meets the following requirements:
Rack, wall, or shelf space is available for proper mounting.
If mounting on a rack, it must be 19”. A 23” rack can be used if a 23” rack mounting bracket is ordered with the XMU+ unit. Record the rack size and mounting method in
The XMU+ Delivery Checklist on page 21.
The XMU+ is designed to operate within a 0 - 40 degrees o C (32 - 104 o F) temperature range. Adequate cooling or heating must be provided to guarantee this range.
HVAC requirements must also be met:
The large chassis XMU+ produces a maximum of 750 BTU/hour of waste heat, while the small chassis XMU+ produces a maximum of 160 BTU/hour of waste heat.
Note: The actual amount of waste heat generated by the XMU+ depends on the number and type of line cards and Power Supply cards installed.
See Chapter 11: XMU+ Technical Specifications and Approvals for more detailed thermal
information.
UPS
Uninterruptible
Power Supply
XMU+ Installation and Maintenance Guide rev.07
17
Meeting System Requirements
Power Requirements
Depending on the number and types of line cards installed, the large chassis XMU+ can consume as much as 220 Watts, while the small chassis XMU+ can consume as much as
50 Watts. See
Chapter 11: XMU+ Technical Specifications and Approvals for more power
consumption information.
To meet XMU+ power requirements, ensure that the necessary power sockets (AC or DC) are available, unoccupied, and have a protective earth/ground connection.
Note: Since the AC power cord is the disconnect for the XMU+, ensure that the AC receptacle is
near the unit. See XMU+ Approvals on page 143 for more information.
Bitte beachten Sie die wichtien Sicherheits informationen auf Seite 135, XMU+ Technical
Specifications and Approvals .
If the operation on a UPS is required, ensure that the appropriate UPS requirements
(power and runtime) are determined.
The power rating must be at least that of the XMU+ system. (See
Technical Specifications and Approvals
for specific XMU+ system ratings).
The amount of runtime is up to the user.
For a large chassis XMU+, the dual Power Supply cards can be used to provide a degree of power supply diversity. For example, two AC supplies could be used, each connected to a different branch circuit.
PBX Requirements
The functionality of the XMU+ is dependent on the type of PBX (switch) with which it is used. See
Cabling XMU+ Line Cards on page 54 for more information. Before you begin to
install the XMU+ unit, you should identify your PBX and ensure that the information is
readily available by recording it below, as well as in The XMU+ Delivery Checklist on page
Your PBX Information
Switch manufacturer:
Model name:
Model number:
18 Chapter 2
Before You Start
Delivery Checklist
The installer must collect initial XMU+ installation and configuration
information, and record it in The XMU+ Delivery Checklist on page 21 for
those who may:
Use XMUCOM+ software to configure the XMU+. See the XMU+
QuickStart Guide for more information about configuring XMU+.
Perform standard maintenance or upgrades on the XMU+. See
Troubleshoot the XMU+ at a later date. See Chapter 10: Troubleshooting
In this chapter...
Preparing the XMU+ Delivery Checklist on page 19.
The XMU+ Delivery Checklist on page 21.
Preparing the XMU+ Delivery Checklist
The XMU+ Delivery Checklist on page 21 should be prepared by installers as
they are installing the XMU+, and should be updated whenever the XMU+ or its configurations are upgraded. The Delivery Checklist provides cross-references to the appropriate sections in this manual for easy location of required information at a later date.
3
20 Chapter 3
Delivery Checklist
XMU+ Installation and Maintenance Guide rev.07
21
The XMU+ Delivery Checklist
The XMU+ Delivery Checklist
Initial XMU+ installation information should be collected by the installer and recorded in the Delivery Checklist for later use. This information can include:
Physical Specifications on page 21.
Configuration Specifications on page 23.
Communication Specifications on page 25.
This list should be updated whenever the XMU+ or its configurations are upgraded.
Physical Specifications
Installation Specifications
Serial number of this XMU+. The serial number is found on the top edge of the XMU+ unit.
_________________________
Large or small chassis? Large Small
Physical location of XMU+ unit.
Is the XMU+ mounted on a wall or shelf?
Is the XMU+ mounted on a rack?
If yes, what is the size of the rack (19” or 23”)?
See Environmental Requirements on page 16.
_________________________
Yes No
Yes No
19” 23”
Power Supply Specifications
Power Supply card part #.
What is the XMU+ primary power supply?
Is there a secondary power supply?
If yes, what is the secondary power supply?
_________________________
AC DC
Yes No
AC DC
22 Chapter 3
Delivery Checklist
Control Card Specifications
Control card part #?
See Cabling the XMU+ Control Card on page 47.
_________________________
Is Telephone Remote Access set up?
Yes No
If yes, what is the:
Remote Access mode? See
Remote Telephone Access mode on page 86.
Remote Access code? See
Remote Telephone Access code on page 87.
Remote Access telephone number. See
Connecting Remote Telephone Access (optional) on page 51.
_________________________
_________________________
_________________________
Are alarms connected?
Yes No
If an alarm connector was used, where do the signals go? _________________________
Line Cards
Installed
Line Card
Name
Line Card
Part #
Total # of Lines
Operating
Mode
See Line Card Checklist on page
particular type of line card can be installed.
XMU+ Cables and Connectors on page 43.
See To set line card operating modes on page
Slot# 1 ________________ ____________ ______________ _______________
Slot# 2 ________________ ____________ ______________ _______________
Slot# 3 ________________ ____________ ______________ _______________
Slot# 4 ________________ ____________ ______________ ______________
Slot# 5 ________________ ____________ ______________ ______________
Slot# 6 ________________ ____________ ______________ ______________
Slot# 7 ________________ ____________ ______________ ______________
Slot# 8 ________________ ____________ ______________ ______________
XMU+ Installation and Maintenance Guide rev.07
23
The XMU+ Delivery Checklist
Configuration Specifications
Firmware Specifications
Current firmware version installed.
See To check system startup on page 38.
_________________________
Message Specifications
Available Memory (recording time).
_________________________
Has partitioning been enabled?
If yes, how many partitions have been configured?
Yes No
_________________________
Messages available per partition.
_________________________
Hybrid Analog
Hardware Settings
Slot #
# of cards installed
(up to 8):
Card #1
Card #2
Card #3
Card #4
Card #5
Card #6
Card #7
Card #8
See
Physical Specifications on page 21
_________________________
_________________________
_________________________
_________________________
_________________________
_________________________
_________________________
_________________________
24 Chapter 3
Delivery Checklist
MOH Hardware Settings Slot #
# of MOH cards installed
(up to 4).
___________________
MOH Card #1
MOH Card #2
MOH Card #3
MOH Card #4
Jumper Settings
See
______________ _________________________
______________ _________________________
______________ _________________________
______________ _________________________
T1 Hardware
Settings
Slot # Primary Settings Secondary
Settings
# of T1 cards installed
(up to 2):
___________________
T1 Card #1
T1 Card #2
See
See the RJ45 pinout diagram in
Chapter 3 of the
XMU+ Installation
Handbook.
See Chapter 3 of the
XMU+ Installation
Handbook.
__1____________ __________________ _________________
__5____________ __________________ _________________
XMU+ Installation and Maintenance Guide rev.07
25
The XMU+ Delivery Checklist
Communication Specifications
Contact the appropriate department (usually the IT department) if the following information is not readily available.
Telephone and Extension Specifications
# of available telephone numbers.
What are the telephone numbers (or range of numbers)?
# of available extensions.
What are the extension numbers (or range of extension numbers)?
# of extensions required (must be less than or equal to the number of extensions available).
_________________________
_________________________
_________________________
_________________________
_________________________
PBX Specifications
Who is the PBX (switch) manufacturer?
What is the PBX model name?
What is the PBX model number?
What year was the PBX manufactured
(approximately)?
_________________________
_________________________
_________________________
_________________________
26 Chapter 3
Delivery Checklist
XMU+ to XMUCOM+ Communication Specifications
Which communication option was chosen for communication between XMU+ and XMUCOM+:
Modem.
Ethernet (LAN).
Ethernet (direct).
See Connecting the XMU+ to a PC with XMUCOM+
_________________________
If a modem connection was set up, what is the telephone number?
If an Ethernet connection was set up, what is the:
IP address?
IP netmask?
IP gateway subnet?
_________________________
_________________________
_________________________
_________________________
Applying Hardware Settings to XMU
+
Line Cards
Each XMU+ line card is unique, in both its design and its effect on the functional capabilities of the XMU+. Some XMU+ line cards require specific settings to be applied so they can perform appropriately with your PBX. These line cards include:
MOH. See
Applying MOH Line Card Settings on page 31.
4
ESD
Electrostatic
Discharge
Caution: The application and modification of settings for
XMU+ line cards should only be completed by a qualified telecommunications / electronics technician. Standard static discharge precautions must be followed when handling any internal components. ESD precautions should also be observed.
Interalia cannot be held responsible for damage to parts or equipment caused by improper handling or installation.
In this chapter...
Applying Hardware Settings Activities on page 29.
Understanding Line Card Population Rules on page 30.
Applying MOH Line Card Settings on page 31.
28 Chapter 4
Applying Hardware Settings to XMU+ Line Cards
XMU+ Installation and Maintenance Guide rev.07
29
Applying Hardware Settings Activities
Applying Hardware Settings Activities
Complete the following activities to apply the appropriate settings to XMU+ line cards:
Apply Hardware Settings
Gather Required
Information
Understand
Population Rules
Apply Line Card
Settings
MOH
T1 Hybrid
2.
3.
1.
Ensure that the following information has been gathered, and is close at hand:
PBX information. See PBX Requirements on page 17 for more information.
Identify the slots into which the Hybrid Analog, T1 or MOH line cards were pre-installed in your XMU+. See
Line Card Checklist on page 14 for more
information.
Understand population rules for line card placement. See Understanding Line
Card Population Rules on page 30 for more information.
Apply hardware settings to the appropriate line cards. See the following for more information:
MOH. See
Applying MOH Line Card Settings on page 31.
30 Chapter 4
Applying Hardware Settings to XMU+ Line Cards
Understanding Line Card Population Rules
The XMU+ small chassis has one slot for placement of a line card, while the XMU+ large chassis has eight slots for line card placement.
Small Chassis
Slot 1
Large Chassis
Line cards have associated population rules that determine the slots in which they can be placed in the XMU+ unit. Installing more than the advised number of line cards, or installing a line card in an invalid slot, could cause the XMU+ system to fail.
Small Chassis: Maximum of one (1) card of any type.
Large Chassis:
Maximum of four (4) MOH cards @ 8ohm or eight (8) @ 600 ohm.
Maximum of two (2) T1 cards in an XMU+ large chassis.
T1 cards can only be placed in the 1st and 5th slots, since they control not only the slot they are placed in, but also the following 3 slots.
For example, when a T1 card is plugged into slot 5, it controls slots 5 to 8, but slots 1 to 4 are still available for other line cards. If T1 line cards are placed in both slot 1 and slot 5, no other cards can be added.
Maximum of eight (8) Hybrid Analog line cards.
Usually, unusable slots display a faceplate with the following warning sticker:
XMU+ Installation and Maintenance Guide rev.07
31
Applying MOH Line Card Settings
Applying MOH Line Card Settings
The MOH line card combines music and messages to create an ‘On Hold’ environment for callers that are on hold. Music and messages can be recorded within the XMU+, or the music can be provided from an external source. You can install one MOH line card in an XMU+ small chassis, and up to four MOH line cards in an XMU+ large chassis.
Each MOH card has two input slots for use when music is provided by an existing external source, such as Muzak.
The MOH card also has four output slots that connect to the MOH inputs on a PBX. These audio outputs are used in one of two ways:
To output messages in combination with an existing music source.
To output music and messages that reside in the XMU+.
These inputs and outputs are located on the MOH line card’s face plate, as shown below:
To set MOH Jumper Settings
By default, the MOH line card is set to 600Ω output impedance. If 8Ω output impedance is required for any of the four MOH outputs, you will need to apply the following jumper settings to the appropriate jumper on the MOH line card.
The four sets of 8Ω/600Ω jumpers are located on the side of the MOH line card. Each set of jumpers corresponds to an MOH output:
This MOH output...
OUT4
OUT3
OUT2
OUT1
Corresponds to this set of jumpers...
J2
J4
J18
J11
32 Chapter 4
Applying Hardware Settings to XMU+ Line Cards
1.
2.
3.
4.
Locate the MOH line card in the back of the XMU+ unit.
See Line Card Checklist on page 14 for more information.
Loosen the two thumbscrews on either end of the line card’s faceplate.
Pull the line card straight out.
Locate the four sets of 8Ω/600Ω jumpers on the side of the line card, as shown below.
Jumper 2
Jumper 4
Jumper18
Jumper 11
Caution...
Forcing the line card into place could bend the pins on the connector.
5.
Set one set of jumpers by applying clips to the following pins:
Jumper Set
Pins 1-2 for 8Ω.
Pins 2-3 for 600Ω.
Pin 3
6.
Repeat step 5 until the correct jumper settings have been applied to each of the four sets of jumpers.
Pin 2
Pin 1
7.
8.
Line up the line card’s circuit board on the plastic rails in the chassis.
Slide the line card into place.
When seating the line card, there should be slight resistance. Do not force the line card into place.
9.
Tighten the thumbscrews.
10.
Repeat Steps 1 to 8 until the appropriate jumper settings have been applied to all MOH line cards in the XMU+.
ESD
Electrostatic
Discharge
Installing the XMU
+
The XMU+ unit must be installed in a location that meets all the requirements detailed in
Meeting System Requirements on page 16. The
installation process consists of physical installation at the appropriate location, connecting the XMU+ to its designated power supply, and checking system startup.
Before beginning the installation process, line card settings must be applied
to the appropriate line cards. See Chapter 4: Applying Hardware Settings to
Caution: The installation of an XMU+ unit should only be completed by a qualified telecommunications / electronics technician. Standard static discharge precautions must be followed when handling any internal components. ESD precautions should also be observed.
Interalia cannot be held responsible for damage to parts or equipment caused by improper handling or installation.
In this chapter...
Installation Activities on page 35.
Installing the XMU+ Unit on page 36.
Checking System Startup on page 38.
5
34 Chapter 5
Installing the XMU+
XMU+ Installation and Maintenance Guide rev.07
35
Installation Activities
Installation Activities
Complete the following activities to install the XMU+:
Install
XMU+
Install XMU+
Connect XMU+ to
Power Supply
Check
System Startup
1.
2.
3.
If required, install the XMU+ in a rack or on a wall.
See To install an XMU+ in a rack on page 36 or
To mount an XMU+ to a wall on page 37 for more information.
Connect the XMU+ to its power supply. For the large chassis, could be to one or both of the following power supplies:
AC power.
DC power.
See “Connecting the XMU+ to its Power Supply” in Chapter 2 of the XMU+
Installation Handbook for more information.
Check to ensure proper system startup. See
Checking System Startup on page 38
for more information.
36 Chapter 5
Installing the XMU+
Installing the XMU
+
Unit
Before installing the XMU+ unit, you should ensure that all system requirements have been met (see
Meeting System Requirements on page 16) and that all of the
appropriate line cards settings have been applied (see
As well, you should ensure that the following tools, hardware, and accessories are near:
The XMU+ unit.
Mounting brackets and screws.
Philips screwdriver.
To install an XMU
+
in a rack
1.
Ensure you have the mounting brackets.
2.
Attach the rack mounting bracket to the XMU+ with the screws provided, as shown below: screws
(4 per side) flange
Small Chassis screws
(4 per side)
3.
flange
Large Chassis
Install the XMU+ in the rack using the flanges of the mounting brackets.
XMU+ Installation and Maintenance Guide rev.07
37
Installing the XMU+ Unit
To mount an XMU
+
to a wall
19” rack mounting brackets can be turned 90 o and used to mount a large chassis
XMU+ on a wall. Small chassis XMU+ units must be ordered with specific wall mounting brackets.
1.
Attach the mounting brackets to the XMU+ with the screws provided, as shown below: flange screws
(4 per side)
2.
Use appropriate screws to mount the XMU+ to a plywood backboard.
Note: Do not mount the XMU+ directly to standard wall board material.
38 Chapter 5
Installing the XMU+
Checking System Startup
At system startup, the XMU+ identifies the current system configuration. You should watch the information displayed on the LCD to ensure that the XMU+ is working correctly.
Since the system configuration information may be required at a later date for maintenance and upgrades, you should record it in the Delivery Checklist. See the
section of The XMU+ Delivery Checklist on page 21.
To check system startup
1.
2.
3.
Attach the XMU+ to the appropriate power supply.
Verify that the LCD illuminates.
Verify that the XMU+ identifies the current system configuration in the following order:
The current firmware version installed.
Proper loading of messages and prompts.
The total amount of recording time currently installed.
The amount of recording time that is currently available.
The date and time.
The date and time may have to be reset to show the correct values. See
(from the Front Panel) on page 96.
ESD
Electrostatic
Discharge
Cabling the XMU
+
Cabling the XMU+ involves connecting and/or wiring each line card to the appropriate PBX, transmitter, or amplifier. In addition, it involves cabling the Control card to the appropriate connections, which could include:
Alarm connection.
Telephone lines for Remote Access and modem connections.
Ethernet (network or direct) connection.
Caution: The cabling of the XMU+ to the PBX should only be completed by a qualified telecommunications / electronics technician. Standard static discharge precautions must be followed when handling any internal components. ESD precautions should also be observed.
Interalia cannot be held responsible for damage to parts or equipment caused by improper handling or installation.
In this chapter...
Cabling Activities on page 41.
Preparing to Cable the XMU+ on page 42.
Cabling the XMU+ Control Card on page 47.
Cabling XMU+ Line Cards on page 54.
Common Interface Tables (By Application) on page 56.
About XMU+ Operating Modes on page 68.
6
40 Chapter 6
Cabling the XMU+
XMU+ Installation and Maintenance Guide rev.07
41
Cabling Activities
Cabling Activities
Complete the following activities to connect and wire the XMU+:
Cable XMU+
Prepare to
Cable XMU+
Cable XMU+
Control Card
Remote Access
XMUCOM+
Alarm
Connect and Wire
Line Cards
Hybrid MOH
T1 MWR
Low Impedance
Understand PBX
Operating Modes
1.
2.
3.
4.
Ensure that the appropriate preparations are taken before cabling the XMU+.
See Preparing to Cable the XMU+ on page 42.
Cable the Control card to the appropriate connections.
See Cabling the XMU+ Control Card on page 47.
Connect and wire the appropriate XMU+ line cards using the
Interface Tables (By Application) on page 56. See the following for more
information:
To cable Hybrid Analog line cards on page 54.
To cable Low Impedance cards on page 54.
To cable T1 line cards on page 54.
To cable MOH line cards on page 55.
To cable MWR line cards on page 55.
Understand PBX operating modes.
See About XMU+ Operating Modes on page 68.
42 Chapter 6
Cabling the XMU+
Preparing to Cable the XMU+
To properly cable the various Control card connections, as well as to wire and connect
XMU+ line cards to the PBX, you should ensure that the following prerequisites have been met:
Ensure that all system requirements have been met.
See Meeting System Requirements on page 16.
Ensure that the appropriate cables are available for connecting and wiring the XMU+.
See Matching XMU+ Cables and Connectors on page 43.
As always, cables should be properly managed during XMU+ connecting and wiring, and properly stored after installation.
Match the connector pinouts to specific line cards.
See Matching Connector Pinouts to XMU+ Line Cards on page 45.
Understand the PBX table conventions used in this chapter.
See PBX Interface Table Conventions and Abbreviations on page 42.
PBX Interface Table Conventions and Abbreviations
The following color abbreviations are used in the PBX interface tables (see Common
Interface Tables (By Application) on page 56):
Abbreviation...
Cable Color...
Blk
Brn
Red
Org
Yel
Black
Brown
Red
Orange
Yellow
Abbreviation...
Grn
Blu
Vlt
Slt
Wht
Cable Color...
Green
Blue
Violet
Slate
White
In addition, the following conventions are used in the PBX interface tables (see
Interface Tables (By Application) on page 56):
This Convention...
Identifies...
Pin
Color
*
The pin number on the 50 position connector.
The wire color/stripe color for the wire corresponding to the pin on the 50 position connector.
The signal from PBX power supply or system ground.
ACD
Automatic Call
Distribution
MWR
Mini Weather
Radio
MOH
Music On Hold
CAT5
Standard
Category 5
XMU+ Installation and Maintenance Guide rev.07
43
Preparing to Cable the XMU+
Matching XMU
+
Cables and Connectors
Use the following table to match Control card and line card connectors to the appropriate cables and mating connectors. While Control card connectors are the same on every XMU+ unit, the number and type of line cards can vary. See
Checklist on page 14 for a list of the line cards pre-installed in the XMU+.
Some cables are shipped with the XMU+, but others may need to be purchased separately. See “Cable Checklist” in Chapter 1 of the XMU+ Installation Handbook for a list of cables shipped with this XMU+.
XMU+
Card...
Control
Card
Connector on card...
MODEM -
RJ-11 connector
REMOTE -
RJ-11 connector
Used to...
Requires connector and cable...
Communicate with
XMUCOM+.
Program messages from a remote location using a touch tone telephone.
RJ-11 Mating Connector
(telephone jack) and telephone cable.
RJ-11 Mating Connector
(telephone jack) and telephone cable.
Low
Impedance
Line Card
MWR Line
Card
ALARM -
Alarm
Connector
SERIAL-1
SERIAL-2
NETWORK -
RJ-45
J5 - RJ-21
Female
Connector
J5 - RJ-21
Female
Connector
Connect alarm circuitry.
Alarm Mating Connector and ribbon cable.
Perform future applications.
Perform future applications.
Set up connections to
XMUCOM+ software via an Ethernet network.
Perform ACD/UCD applications only.
Perform MWR applications only.
RJ-45 to RJ-45 (6ft.)
Category 5 UTP network connector and cable for
LAN connection.
Amphenol RJ-21
50-pin male connector and cable.
Amphenol RJ-21
50-pin male connector and cable.
44 Chapter 6
Cabling the XMU+
XMU+
Card...
MOH Line
Card
Hybrid
Analog
Line Card
T1 Line
Card
Connector on card...
2 RCA /Phono
Inputs
4 RCA/ Phono
Outputs
J5 - RJ-21
Female
Connector
RJ-45 Female
Connector
Used to...
Perform MOH applications only.
Perform ACD, Call
Processing, and Auto
Attendant applications.
Perform ACD, Call
Processing, and Auto
Attendant applications.
Requires connector and cable...
Standard RCA/Phono connector and suitable coaxial cable.
Amphenol RJ-21
50-pin male connector and cable.
RJ-45 mating connector and Standard Category 5
(CAT5) UTP cable.
XMU+ Installation and Maintenance Guide rev.07
45
Preparing to Cable the XMU+
Matching Connector Pinouts to XMU+ Line Cards
Most XMU+ line cards are cabled using the
RJ-21 50-pin Connector on page 45.
Exceptions include:
The MOH line card, which uses the
RCA/Phono Connectors on page 46.
T1 line cards, which use a digital signal to connect to the XMU+.
All connectors are used to connect and wire the line cards to a PBX, as described in
the various PBX interface tables found in Cabling XMU+ Line Cards on page 54.
RJ-21 50-pin Connector
Use the Amphenol RJ-21 50-pin Connector to connect the following line cards to telephone lines or PBX trunks:
Hybrid Analog line card. See To cable
Hybrid Analog line cards on page 54 for
more information.
Low Impedance line card. See
Low Impedance cards on page 54 for
more information.
MWR line card. See To cable MWR line cards on page 55 for more information.
Each line on the Amphenol 50-pin connector has a tip (-)/ring (+) pair. The tip/ring pair performs like a regular telephone extension operating in the Ring
Start Mode (see
Modes on page 68 for more information).
For lines operating in other modes, the tip/ring pair provides the message audio path.
46 Chapter 6
Cabling the XMU+
RCA/Phono Connectors
Use RCA/Phono connectors to connect MOH line cards to a PBX and/or an external music source. The two MOH input slots are used when music is provided by an existing external source, such as Muzak. The four MOH output slots connect to the MOH inputs on the PBX.
The following table outlines these input/output slots:
These connectors...
IN1
IN2
OUT1
OUT2
OUT3
OUT4
Do this...
Accepts a wide dynamic range of audio input (20mVrms to
1.6Vrms) to yield good recording quality audio.
600Ω output impedance drives a high impedance load such as “Line in” of a PA system, Music on Hold input of a key system, transmitter input, etc.
8Ω output impedance drives standard 8Ω speakers.
Each output volume is adjustable up to the following levels:
-
8Ω - 1.0
Vrms.
- 600Ω -
(8Vpp or =9dBm).
See
XMU+ Technical Specifications and Approvals on page 135 for more detailed technical
specifications.
XMU+ Installation and Maintenance Guide rev.07
47
Cabling the XMU+ Control Card
Cabling the XMU+ Control Card
The XMU+ Control card must be cabled to handle the inputs and outputs from alarms, remote access, and PC communications. The Control card has 6 connector ports, as shown below:
This Port...
Is used by XMU+ to...
See...
MODEM
(RJ-11 connector)
Provide external communication with
XMUCOM+ software.
Modem Status
Indicators
To connect to the PC with an analog line to modem on page
The indicator displays the MODEM port status:
Green - carrier detect.
Yellow - transmit and receive data.
REMOTE
(RJ-11 connector)
Program messages from a remote location using a touch tone telephone.
Connecting Remote Telephone Access
ALARM
(2 x 5 header connection)
SERIAL-1
(RS-232 connector)
Connect XMU+ to alarm circuitry.
Provide future applications.
Connecting Alarms (optional) on page 52.
TBA.
SERIAL-2
(RS-232 connector)
Provide future applications.
NETWORK
(RJ-45 connector)
Provide external communication with
XMUCOM+ software.
Network Status
Indicators
TBA.
To connect to the PC through an
Ethernet (LAN) Network on page 50.
The indicators display the NETWORK port status:
Green (in connector)- link.
Yellow (in connector) - activity (transmit and receive data).
Green - 100 Base T (when on) and 10 Base T (when off).
Yellow - collision.
48 Chapter 6
Cabling the XMU+
Connecting the XMU
+
to a PC with XMUCOM
+
Software
The XMUCOM+ software is a Windows based program that allows you to program, download, update, and backup configurations and messages to the XMU+ from a PC.
See the XMU+ QuickStart Guide for more information about XMUCOM+ software and configurations.
Users that have multiple XMU+ units distributed across several geographical sites must consider how to interconnect and communicate with the various units.
Depending on the location, available network facilities, and modem capabilities of the
XMUCOM+ system and XMU+ units, users can choose to apply a combination of one or more of the following communication methods for each of their XMU+ sites:
Use...
Modem
Connection
Ethernet
(LAN)
Connection
To let the XMU+ communicate with XMUCOM+...
Through a dial-up modem connection. This method is effective for sites that are not linked through LAN/WAN networks.
Modem connections require PC’s with a modem, and the modem phone numbers for the XMU + unit.
See To connect to the PC with an analog line to modem on page 49
for more information.
Through LAN/WAN networks. This method is effective for organizations that have existing LAN/WAN networks operating at all
XMU+ sites.
Ethernet connections require:
A network card to be installed within the XMUCOM+ PC.
Both the PC and XMU+ unit be connected to the network for LAN access.
A fixed IP address for the XMU+ unit.
An IP address for the XMUCOM+ (Admin) PC.
See To connect to the PC through an Ethernet (LAN) Network on page
POTS Line
POTS
Plain Old
Telephone
Service
XMU+ Installation and Maintenance Guide rev.07
49
Cabling the XMU+ Control Card
Use...
Direct
Ethernet
Connection
To let the XMU+ communicate with XMUCOM+...
With a non-LAN Ethernet connection by connecting the network port of a PC directly to the network port on the XMU+ using an
Ethernet cable.
Use this method if your PC is equipped with a network card, but does not have an available LAN to connect with. The Ethernet cable creates a separate network connection between the PC and the
XMU+ unit.
Direct Ethernet connections require:
A network card to be installed within the XMUCOM+ PC.
An Ethernet Cable.
An IP address for the XMU+ unit (default on unit is 192.168.100.2)
An IP address for the XMUCOM+ (Admin) PC.
See To connect to the PC directly with the Network port on page 50
for more information.
The best way for XMU+ to communicate with XMUCOM+ depends on the communication systems currently available in the environment in which the XMU+ will be placed. Record the communication option chosen in the Delivery Checklist.
See The XMU+ Delivery Checklist on page 21.
Note: Ideally, the XMUCOM+ software and the XMU+ unit should be installed concurrently so that full testing can be completed. See
Testing XMU+ Line Connections on page
100 and the XMU+ QuickStart Guide
for more information.
To connect to the PC with an analog line to modem
2.
3.
The XMU+ provides a modem access port, which is accessed through the MODEM connector on the Control card. See
Cabling the XMU+ Control Card on page 47 for
more information. An analog line is connected (using a standard telephone jack and cable) to the XMU+.
1.
Ensure that a vacant, active telephone outlet is nearby. If one is not nearby, install one. Always take the following safety precautions when installing or modifying telephone lines:
Never install wiring during a lightning storm.
Never install a jack in a wet location unless the jack is specifically designed for wet locations.
Never touch uninsulated wires or terminals unless the lines have been disconnected at the network interface.
Connect the one end of the POTS line to the RJ-11 modem port on the XMU+.
Plug the free end of the POTS line into the vacant, active telephone outlet.
50 Chapter 6
Cabling the XMU+
To connect to the PC through an Ethernet (LAN) Network
The XMU+ provides a RJ-45 port to connect to the XMU+ to a PC via a network. See
Cabling the XMU+ Control Card on page 47 for more information.
1.
Ensure that a vacant, active network outlet is nearby. If one is not nearby, install one. Always take the following safety precautions when installing or modifying network lines:
Never install wiring during a lightning storm.
Never install a jack in a wet location unless the jack is specifically designed for wet locations.
Never touch uninsulated wires or terminals unless the lines have been disconnected at the network interface.
2.
Connect one end of the RJ-45 to RJ-45 cable to the NETWORK RJ-45 port on the
XMU+. See “Cable Checklist” in Chapter 1 of the XMU+ Installation Handbook for more information about the RJ-45 to RJ-45 cable.
3.
Plug the free end of the RJ-45 to RJ-45 cable into the vacant, active network outlet.
4.
Ensure the “link” LED is on (green). If it is not on, troubleshoot.
To connect to the PC directly with the Network port
Ethernet (direct) connections require the following:
It is possible to create a non-LAN Ethernet connection by connecting the network port of a PC directly to the network port on the XMU+ with an Ethernet cable. In this case, the data transfer speeds are much faster than direct connection (RS-232). See
Cabling the XMU+ Control Card on page 47 for more information.
1.
2.
Ensure that there is a vacant Network port on the PC.
Connect one end of the Ethernet cable to the NETWORK RJ-45 port on the
XMU+.
3.
4.
Plug the free end of the Ethernet cable into the PC’s Network port.
Ensure the “link” LED is on (green). If it is not on, troubleshoot.
XMU+ Installation and Maintenance Guide rev.07
51
Cabling the XMU+ Control Card
DTMF
Dual Tone
Multi Frequency
Remote Access connections require the following:
POTS Line
POTS
Plain Old
Telephone
Service
Connecting Remote Telephone Access (optional)
The XMU+ provides a remote telephone access port, which is accessed through the
REMOTE RJ-11 connector on the Control card. See
Cabling the XMU+ Control Card on page 47 for more information.
An analog line is connected (using a standard telephone jack and cable) to the XMU+ to provide Remote Access to the XMU+. Remote Access allows control of the XMU+ from a remote location using a DTMF (touch tone) telephone. Thus an operator who is not in the same room as the XMU+, or who does not have XMUCOM+ installed on their PC, can still create and modify XMU+ messages.
If this Remote Access option is connected, record it in the Delivery Checklist. See
Physical Specifications on page 21.
To connect an analog line to provide Remote Telephone Access
1.
Ensure that a vacant, active telephone outlet is nearby. If one is not nearby, install one. Prior to working with telephone lines, please refer to the following safety considerations:
Never install telephone wiring during a lightning storm.
Never install a telephone jack in a wet location unless the jack is specifically designed for wet locations.
Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.
Always use caution when installing or modifying telephone lines.
2.
Connect the one end of the POTS line or analog extension to the RJ-11 remote access port on the XMU+.
3.
Plug the RJ-11 Mating Connector (telephone jack) on the opposite end of the
POTS line or analog extension into the vacant, active telephone outlet.
4.
Configure the XMU+ to allow Remote Access. See Understanding XMU+
Remote Telephone Access on page 85.
52 Chapter 6
Cabling the XMU+
Connecting Alarms (optional)
The XMU+ provides two output alarm contacts and two input alarm contacts, all of which are accessed through the contact pinout on the Control card.
This alarm contact...
Is used to...
For more information...
Output 1
Output 2
Input 1
Input 2
Trigger an external device (a light or a buzzer) in the event of a system failure, such as input power loss or microprocessor failure.
Trigger an external device or monitor in the event that one of the two power supplies fails (this feature only on an
XMU+ large chassis unit with a dual power supply).
Connect the optional override switch feature. When connected to the XMU+, the override switch allows regular programming to be overridden by a prerecorded message in case of an emergency.
Reserved for future use.
See
To wire the alarm connector on page 53 for more
information).
See
To wire the alarm connector on page 53 for more
information).
See the XMUCOM+ application to program override messages.
Information not yet available for this future feature.
Record the alarm option chosen (connector or override switch) in The XMU+ Delivery
XMU+ Installation and Maintenance Guide rev.07
53
Cabling the XMU+ Control Card
Alarm connections require the following:
Alarm Mating
Connector
2.
3.
5
3
4
1
2
To wire the alarm connector
When the system is powered up and running normally, there is a closed circuit between the Common (C) and the Normally Closed (NC) contacts, and an open circuit between the Common (C) and the Normally Open (NO) contacts. In an alarm condition, the opposite occurs, with an open circuit between the (C) and the (NC) contacts, and a closed circuit between the (C) and the (NO) contacts.
1.
Wire the connector pinouts on the alarm connector using the following table.
Pin...
Used for...
Pin...
Used for...
Alarm 1 Output (NC).
Alarm 1 Output (NO).
Alarm 1 Output (C).
Alarm 2 Input.
6
7
8
9
Alarm 1 Input.
Alarm 2 Output (NC).
Alarm 2 Output (NO).
Alarm 2 Output (C).
Alarm 1 Input.
10 Alarm 2 Input.
Connect the wires to the appropriate external device, such as a light or a buzzer.
Plug the alarm mating connector into the ALARM port on the XMU+ control card.
Alarm pin out on the XMU+ Control Card
54 Chapter 6
Cabling the XMU+
Cabling XMU
+
Line Cards
The diverse applications that the XMU+ can execute is made possible by the various line cards that can be installed. Each line card must be cabled individually to the PBX, transmitter, or amplifier. This section describes the procedures for cabling XMU+ line cards.
To cable Hybrid Analog line cards
2.
3.
4.
Hybrid Analog line cards give the XMU+ the ability to provide Auto-Attendant/
Audiotex announcements, 1-800 ACD call routing, and ACD/UCD intercept messages.
Hybrid Analog line cards replace the Passive and Interactive Line Cards by combining their features. Cable the Hybrid Analog line card using the steps shown below.
1.
Verify that PBX line cards are configured for the appropriate XMU+ application
Punch down wires from PBX to the punch block.
Punch down wires from XMU+ to the punch block.
Cross connect the wires in the punch block as per the following PBX tables:
Call Processing/Auto Attendant Applications on page 56. This table is also
used to cable Interactive line cards in older XMU units.
ACD Applications on page 57. These tables are also used to cable Passive
line cards in older XMU units.
To cable Low Impedance cards
2.
3.
4.
Low Impedance XMU+ line cards are used to provide ACD/UCD messages. However,
Low Impedance cards can connect one (1) passive port to twenty-four (24) PBX trunks. Low Impedance line cards can only be used with Nortel PBXs.
1.
Verify that PBX line cards are configured for the appropriate ACD application.
See About XMU+ Operating Modes on page 68 for more information.
Punch down wires from PBX to punch block.
Punch down wires from XMU+ to punch block.
Cross connect the wires in the punch block as per the appropriate (Nortel only)
ACD Applications
To cable T1 line cards
T1 XMU+ line cards connect to a T1 communication link on a PBX to provide the
XMU+ with 24 T1 user channels.
XMU+ Installation and Maintenance Guide rev.07
55
Cabling XMU+ Line Cards
1.
2.
3.
Verify that PBX line cards are configured for the T1 application.
See About XMU+ Operating Modes on page 68 for more information.
Verify that the T1 hardware settings are correct.
See Chapter 3 of the XMU+ Installation Handbook.
Use a CAT5 cable to connect the RJ-45 port on the T1 line card directly to the communication link on the PBX.
To cable MOH line cards
5.
6.
3.
4.
MOH line cards combine music (from an external or internal source) and messages to create an “On Hold” environment for the XMU+.
1.
Verify that PBX line cards are configured for the MOH application.
See About XMU+ Operating Modes on page 68 for more information.
2.
Verify that the MOH hardware settings are correct.
See Applying MOH Line Card Settings on page 31.
Verify that PBX line cards are correct.
Punch down wires from PBX to punch block.
Punch down wires from XMU+ to punch block.
Cross connect the wires in the punch block as per the
MOH Applications table
To cable MWR line cards
2.
3.
MWR line cards provide XMU+ with the ability to broadcast weather information for
Environment Canada.
1.
Wire the XMU+ outputs to the transmitter inputs as per the
MWR Applications
If required, key the transmitter as per the MWR Applications
Repeat steps 1 and 2 until all transmitters are cabled.
56 Chapter 6
Cabling the XMU+
Common Interface Tables (By Application)
The following tables describe the PBX, announcer, and transmitter interfaces for each
XMU+ application.
Call Processing/Auto Attendant Applications on page 56.
There are no tables for T1 line cards as it is not PBX dependent.
Call Processing/Auto Attendant Applications
This table describes the cabling of Hybrid Analog line cards (Ring Start) to the following PBXs:
Public Telephone Network
PBX Analog Station Port.
Analog Centrex Line.
See To cable Hybrid Analog line cards on page 54 for more information.
PABX
Signal
Announcer
Signal
Line 1
Pin-
Color
Line 2
Pin-
Color
Line 3
Pin-
Color
Line 4
Pin-
Color
Line 5
Pin-
Color
Line 6
Pin-
Color
Line 7
Pin-
Color
Ring Ring 1 -
Blu/Wht
4 -
Brn/Wht
7 -
Org/Red
10 -
Slt/Red
13 -
Grn/Blk
16 -
Blu/Yel
19 -
Brn/Yel
Tip Tip 26 -
Wht/Blu
29 -
Wht/Brn
32 -
Red/Org
35 -
Red/Slt
38 -
Blk/Grn
41 -
Yel/Blu
44 -
Yel/Brn
PBX Operation Mode: Ring Start (R). See
About XMU+ Operating Modes on page 68 for more information.
Line 8
Pin-
Color
22 -
Org/Vlt
47 -
Vlt/Org
XMU+ Installation and Maintenance Guide rev.07
57
Common Interface Tables (By Application)
ACD Applications
The XMU+ can be coupled with a variety of PBXs to provide ACD announcements.
The following tables describe the cabling of Hybrid Analog line cards to these PBXs:
GPT iSDX and Realitis; Siemens 9005-9006, HiPath 3000, HiPath 4000; Intecom; ITT
3100; HICOM 300 Series; Mitel SX50, SX200, SX2000, 3300; Toshiba Perception Rolm
9751, CBX 8000, CBX 9000; TadarianCoral. on page 58.
AT&T Dimension 2000 on page 58.
AT&T G2, G3, and Definity (option 1) on page 59.
AT&T G2, G3, and Definity (option 2) on page 59.
Harris 20/20 LH and 20/20 M on page 61.
Hitachi EDX, MDX, and LDX on page 61.
Nortel SL-1®or Meridian-1® (option 1), DMS-100, SL-100,
CS1000 and Centrex on page 64.
Northern Telecom SL-1®or Meridian-1® (option 2) on page 64.
Solid State Junior and Senior Executive on page 66.
See To cable Hybrid Analog line cards on page 54 for more information.
58 Chapter 6
Cabling the XMU+
GPT iSDX and Realitis; Siemens 9005-9006, HiPath 3000,
HiPath 4000; Intecom; ITT 3100; HICOM 300 Series;
Mitel SX50, SX200, SX2000, 3300; Toshiba Perception Rolm 9751,
CBX 8000, CBX 9000; TadarianCoral.
PABX
Signal
Announcer
Signal
Line 1
Pin-
Color
Line 2
Pin-
Color
Line 3
Pin-
Color
Line 4
Pin-
Color
Line 5
Pin-
Color
Line 6
Pin-
Color
Line 7
Pin-
Color
Line 8
Pin-
Color
Ring Ring 1 - Blu/
Wht
4 - Brn/
Wht
7- Org/
Red
10 - Slt/
Red
13 - Grn/
Blk
16 - Blu/
Yel
19 - Brn/
Yel
Tip Tip 26- Wht/
Blu
29 -Wht/
Brn
32 Red/
Org
35 - Red/
Slt
38 - Blk/
Grn
41 - Yel/
Blu
44 - Yel/
Brn
PBX Operation Mode: Ring Start (R). See
About XMU+ Operating Modes on page 68 for more information.
GPT iSDX and Realitis use the 1HAC 50049 ADB card to interface.
22 - Org/
Vlt
47 - Vlt/
Org
AT&T Dimension 2000
PABX
Signal
Announcer
Signal
Line 1
Pin-
Color
Line 2
Pin-
Color
Line 3
Pin-
Color
Line 4
Pin-
Color
Line 5
Pin-
Color
Line 6
Pin-
Color
Line 7
Pin-
Color
Line 8
Pin-
Color
Ring
Tip
Battery
*
S2
Ring
Tip
Start-
Start+
1 -
Blu/Wht
26 -
Wht/Blu
28 -
Wht/Grn
3 -
Grn/Wht
4 -
Brn/Wht
7 -
Org/Red
29 -
Wht/Brn
32 -
Red/Org
10 -
Slt/Red
35 -
Red/Slt
31 -
Red/Blu
6 -
Blu/Red
34 -
Red/Brn
9 -
Brn/Red
37 -
Blk/Org
12 -
Org/Blk
13 -
Grn/Blk
16 -
Blu/Yel
38 -
Blk/Grn
41 -
Yel/Blu
40 -
Blk/Slt
15 -
Slt/Blk
43 -
Yel/Grn
18 -
Grn/Yel
19 -
Brn/Yel
44 -
Yel/Brn
46 -
Vlt/Blu
21 -
Blu/Vlt
22 -
Org/Vlt
47 -
Vlt/Org
49 -
Vlt/Brn
24 -
Brn/Vlt
AL1 CP1 27 -
Wht/Org
30 -
Wht/Slt
33 -
Red/Grn
36 -
Blk/Blu
39 -
Blk/Brn
42 -
Yel/Org
Battery
*
CP2 2 -
Org/Wht
5 -
Slt/Wht
8 -
Grn/Red
11 -
Blu/Blk
14 -
Brn/Blk
17 -
Org/Yel
20 -
Slt/Yel
23 -
Grn/Vlt
PBX Operation Mode: Pulse Start/Level Return (PS/LR NC). See
About XMU+ Operating Modes on page 68 for more
information.
Set the switches on the LC 13 circuit pack as follows: Circuit 0 Circuit 1
45 -
Yel/Slt
48 -
Vlt/Grn
Switch 4 - Open Switch 1 - Open
Switch 5 - Closed
Switch 6 - Open
Switch 2 - Closed
Switch 3 - Open
Connect announcer to Dimension 2000 LC13 Circuit Pack, Recorded Announcement Interface.
XMU+ Installation and Maintenance Guide rev.07
59
Common Interface Tables (By Application)
AT&T G2, G3, and Definity (option 1)
PABX
Signal
Announcer
Signal
Line 1
Pin-
Color
Line 2
Pin-
Color
Line 3
Pin-
Color
Line 4
Pin-
Color
Line 5
Pin-
Color
Line 6
Pin-
Color
Line 7
Pin-
Color
Line 8
Pin-
Color
Ring
Tip
Battery* Start-
S
AL1
Ring
Tip
Start+
CP1
1 -
Blu/Wht
4 -
Brn/Wht
26 -
Wht/Blu
28 -
Wht/Grn
29 -
Wht/Brn
31 -
Red/Blu
3 -
Grn/Wht
27 -
Wht/Org
6 -
Blu/Red
30 -
Wht/Slt
7 -
Org/Red
32 -
Red/Org
34-
Red/Brn
9 -
Brn/Red
33 -
Red/Grn
10 -
Slt/Red
35 -
Red/Slt
37 -
Blk/Org
12 -
Org/Blk
36 -
Blk/Blu
13 -
Grn/Blk
38 -
Blk/Grn
40 -
Blk/Slt
15 -
Slt/Blk
39 -
Blk/Brn
16 -
Blu/Yel
41 -
Yel/Blu
43 -
Yel/Grn
18 -
Grn/Yel
42 -
Yel/Org
19 -
Brn/Yel
44 -
Yel/Brn
46 -
Vlt/Blu
21 -
Blu/Vlt
45 -
Yel/Slt
22 -
Org/Vlt
47 -
Vlt/Org
49 -
Vlt/Brn
24 -
Brn/Vlt
48 -
Vlt/Grn
Ground CP2 2 -
Org/Wht
5 -
Slt/Wht
8 -
Grn/Red
11 -
Blu/Blk
14 -
Brn/Blk
17 -
Org/Yel
20 -
Slt/Yel
23 -
Grn/Vlt
information.
Configuration is using a SN 231 card. Ground must come from Circuit Pack.
AT&T G2, G3, and Definity (option 2)
PABX
Signal
Announcer
Signal
Line 1
Pin-
Color
Line 2
Pin-
Color
Line 3
Pin-
Color
Line 4
Pin-
Color
Line 5
Pin-
Color
Line 6
Pin-
Color
Line 7
Pin-
Color
Line 8
Pin-
Color
Ring
Tip
SZ1
Ring
Tip
Battery* Start-
Start+
1 -
Blu/Wht
26 -
Wht/Blu
28 -
Wht/Grn
3 -
Grn/Wht
4 -
Brn/Wht
29 -
Wht/Brn
31 -
Red/Blu
6 -
Blu/Red
7 -
Org/Red
32 -
Red/Org
34-
Red/Brn
9 -
Brn/Red
10 -
Slt/Red
35 -
Red/Slt
37 -
Blk/Org
12 -
Org/Blk
13 -
Grn/Blk
38 -
Blk/Grn
40 -
Blk/Slt
15 -
Slt/Blk
16 -
Blu/Yel
41 -
Yel/Blu
43 -
Yel/Grn
18 -
Grn/Yel
19 -
Brn/Yel
44 -
Yel/Brn
46 -
Vlt/Blu
21 -
Blu/Vlt
22 -
Org/Vlt
47 -
Vlt/Org
49 -
Vlt/Brn
24 -
Brn/Vlt
S1 CP1 27 -
Wht/Org
30 -
Wht/Slt
33 -
Red/Grn
36 -
Blk/Blu
39 -
Blk/Brn
42 -
Yel/Org
45 -
Yel/Slt
48 -
Vlt/Grn
S CP2 2 -
Org/Wht
5 -
Slt/Wht
8 -
Grn/Red
11 -
Blu/Blk
14 -
Brn/Blk
17 -
Org/Yel
20 -
Slt/Yel
23 -
Grn/Vlt
PBX Operation Mode: Level Start/Pulse Return (LS/PR NO). See
About XMU+ Operating Modes on page 68 for more
information.
Configuration is using a TN 763C card. Ground must come from Circuit Pack, Strap the SZ lead to ground
60 Chapter 6
Cabling the XMU+
AT&T System 75/85
PABX
Signal
Announcer
Signal
Line 1
Pin-
Color
Line 2
Pin-
Color
Line 3
Pin-
Color
Line 4
Pin-
Color
Line 5
Pin-
Color
Line 6
Pin-
Color
Line 7
Pin-
Color
Line 8
Pin-
Color
Ring
Tip
Battery* Start-
S
AL1
Ring
Tip
Start+
CP1
1 -
Blu/Wht
26 -
Wht/Blu
28 -
Wht/Grn
3 -
Grn/Wht
27 -
Wht/Org
4 -
Brn/Wht
29 -
Wht/Brn
31 -
Red/Blu
6 -
Blu/Red
30 -
Wht/Slt
7 -
Org/Red
32 -
Red/Org
34-
Red/Brn
9 -
Brn/Red
33 -
Red/Grn
10 -
Slt/Red
35 -
Red/Slt
37 -
Blk/Org
12 -
Org/Blk
36 -
Blk/Blu
13 -
Grn/Blk
38 -
Blk/Grn
40 -
Blk/Slt
15 -
Slt/Blk
39 -
Blk/Brn
16 -
Blu/Yel
41 -
Yel/Blu
43 -
Yel/Grn
18 -
Grn/Yel
42 -
Yel/Org
19 -
Brn/Yel
44 -
Yel/Brn
46 -
Vlt/Blu
21 -
Blu/Vlt
45 -
Yel/Slt
22 -
Org/Vlt
47 -
Vlt/Org
49 -
Vlt/Brn
24 -
Brn/Vlt
48 -
Vlt/Grn
Ground CP2 2 -
Org/Wht
5 -
Slt/Wht
8 -
Grn/Red
11 -
Blu/Blk
14 -
Brn/Blk
17 -
Org/Yel
20 -
Slt/Yel
23 -
Grn/Vlt
information.
Ground must come from Circuit Pack.
Ericsson MD 110
PABX
Signal
Announcer
Signal
Line 1
Pin-
Color
Line 2
Pin-
Color
Line 3
Pin-
Color
Line 4
Pin-
Color
Line 5
Pin-
Color
Line 6
Pin-
Color
Line 7
Pin-
Color
Line 8
Pin-
Color
T Rec
R Tx
M
Ring
Tip
Start-
1 -
Blu/Wht
4 -
Brn/Wht
26 -
Wht/Blu
29 - Wht/
Brn
7 -
Org/Red
10 -
Slt/Red
32 -
Red/Org
35 -
Red/Slt
28 -
Wht/Grn
3 -
Grn/Wht
31 -
Red/Blu
6 -
Blu/Red
34 -
Red/Brn
9 -
Brn/Red
37 -
Blk/Org
12 -
Org/Blk
13 -
Grn/Blk
16 -
Blu/Yel
38 -
Blk/Grn
41 -
Yel/Blu
40 -
Blk/Slt
15 -
Slt/Blk
43 -
Yel/Grn
18 -
Grn/Yel
19 -
Brn/Yel
44 -
Yel/Brn
46 -
Vlt/Blu
21 -
Blu/Vlt
22 -
Org/Vlt
47 -
Vlt/Org
49 -
Vlt/Brn
24 -
Brn/Vlt
Aux.
GND
Start+
S -GND CP1 27 -
Wht/Org
30 -
Wht/Slt
33 -
Red/Grn
36 -
Blk/Blu
39 -
Blk/Brn
42 -
Yel/Org
45 -
Yel/Slt
48 -
Vlt/Grn
E CP2 2 -
Org/Wht
5 -
Slt/Wht
PBX Operation Mode: Pulse Start/Level Return Single Play (PS/LR SP NO). See
About XMU+ Operating Modes on page 68
for more information.
MD 110 is set to type II 2 wire. Var=00, Type=RA1
Connect S - Batt from PABX to Aux - Batt
8 -
Grn/Red
11 -
Blu/Blk
14 -
Brn/Blk
17 -
Org/Yel
20 -
Slt/Yel
23 -
Grn/Vlt
XMU+ Installation and Maintenance Guide rev.07
61
Common Interface Tables (By Application)
Harris 20/20 LH and 20/20 M
PABX
Signal
Announcer
Signal
Line 1
Pin-
Color
Line 2
Pin-
Color
Line 3
Pin-
Color
Line 4
Pin-
Color
Line 5
Pin-
Color
Line 6
Pin-
Color
Line 7
Pin-
Color
Line 8
Pin-
Color
Ring
Tip
M
Ground* Start+
E
Ring
Tip
Start-
CP1
1 -
Blu/Wht
4 -
Brn/Wht
7 -
Org/Red
10 -
Slt/Red
26 -
Wht/Blu
28 -
Wht/Grn
29 -
Wht/Brn
31 -
Red/Blu
3 -
Grn/Wht
27 - Wht/
Org
6 -
Blu/Red
30 -
Wht/Slt
32 -
Red/Org
34 -
Red/Brn
9 -
Brn/Red
33 -
Red/Grn
35 -
Red/Slt
37 -
Blk/Org
12 -
Org/Blk
36 -
Blk/Blu
13 -
Grn/Blk
16 -
Blu/Yel
38 -
Blk/Grn
40 -
Blk/Slt
41 -
Yel/Blu
43 -
Yel/Grn
15 -
Slt/Blk
39 -
Blk/Brn
18 -
Grn/Yel
42 -
Yel/Org
19 -
Brn/Yel
44 -
Yel/Brn
46 -
Vlt/Blu
21 -
Blu/Vlt
45 -
Yel/Slt
22 -
Org/Vlt
47 -
Vlt/Org
49 -
Vlt/Brn
24 -
Brn/Vlt
48 -
Vlt/Grn
Ground* CP2 2 -
Org/Wht
5 -
Slt/Wht
8 -
Grn/Red
11 -
Blu/Blk
14 -
Brn/Blk
17 -
Org/Yel
20 -
Slt/Yel
23 -
Grn/Vlt
PBX Operation Mode: Level Start/Pulse Return Single Play (LS/PR SP NO). See
About XMU+ Operating Modes on page 68
for more information.
Connect announcer to a 2 wire or 4-wire E&M Trunk Card.
Configure E&M Trunk Card for Type I E&M signaling.
Hitachi EDX, MDX, and LDX
PABX
Signal
Announcer
Signal
Line 1
Pin-
Color
Line 2
Pin-
Color
Line 3
Pin-
Color
Line 4
Pin-
Color
Line 5
Pin-
Color
Line 6
Pin-
Color
Line 7
Pin-
Color
Line 8
Pin-
Color
Ring
Tip
Ring
Tip
Battery* Start-
1 -
Blu/Wht
26 -
Wht/Blu
28 -
Wht/Grn
4 -
Brn/Wht
7 -
Org/Red
10 -
Slt/Red
29 -
Wht/Brn
31 -
Red/Blu
32 -
Red/Org
34 -
Red/Brn
35 -
Red/Slt
37 -
Blk/Org
13 -
Grn/Blk
16 -
Blu/Yel
38 -
Blk/Grn
40 -
Blk/Slt
41 -
Yel/Blu
43 -
Yel/Grn
19 -
Brn/Yel
44 -
Yel/Brn
46 -
Vlt/Blu
22 -
Org/Vlt
47 -
Vlt/Org
49 -
Vlt/Brn
SSLO Start+ 3 -
Grn/Wht
6 -
Blu/Red
9 -
Brn/Red
12 -
Org/Blk
15 -
Slt/Blk
18 -
Grn/Yel
21 -
Blu/Vlt
24 -
Brn/Vlt
PBX Operation Mode: Level Start/Pulse Return Single Play (LS/PR SP NO). See
About XMU+ Operating Modes on page 68
for more information.
Connect announcer to Hitachi card number 4SRBWT. Connect SS0 lead to system ground.
62 Chapter 6
Cabling the XMU+
Hitachi HCX-5000
PABX
Signal
Announcer
Signal
Line 1
Pin-
Color
Line 2
Pin-
Color
Line 3
Pin-
Color
Line 4
Pin-
Color
Line 5
Pin-
Color
Line 6
Pin-
Color
Line 7
Pin-
Color
Line 8
Pin-
Color
Ring
Tip
M
SG
E
Ring
Tip
Start-
Start+
CP1
1 -
Blu/Wht
4 -
Brn/Wht
7 -
Org/Red
10 -
Slt/Red
26 -
Wht/Blu
28 -
Wht/Grn
29 -
Wht/Brn
31 -
Red/Blu
3 -
Grn/Wht
27 -
Wht/Org
6 -
Blu/Red
30 -
Wht/Slt
32 -
Red/Org
34 -
Red/Brn
9 -
Brn/Red
33 -
Red/Grn
35 -
Red/Slt
37 -
Blk/Org
12 -
Org/Blk
36 -
Blk/Blu
13 -
Grn/Blk
16 -
Blu/Yel
38 -
Blk/Grn
40 -
Blk/Slt
41 -
Yel/Blu
43 -
Yel/Grn
15 -
Slt/Blk
39 -
Blk/Brn
18 -
Grn/Yel
42 -
Yel/Org
19 -
Brn/Yel
44 -
Yel/Brn
46 -
Vlt/Blu
21 -
Blu/Vlt
45 -
Yel/Slt
22 -
Org/Vlt
47 -
Vlt/Org
49 -
Vlt/Brn
24 -
Brn/Vlt
48 -
Vlt/Grn
SG CP2 2 -
Org/Wht
5 -
Slt/Wht
8 -
Grn/Red
11 -
Blu/Blk
14 -
Brn/Blk
17 -
Org/Yel
20 -
Slt/Yel
23 -
Grn/Vlt
PBX Operation Mode: Level Start/Pulse Return Single Play (LS/PR SP NO). See
About XMU+ Operating Modes on page 68
for more information.
Set the strapping on the 4 ANIF card as follows: TM00 1-2
TM01 1-2
HCX Programming:
TM02 3-4
TM03 1-2
System Features Screen 2.1.2.1 (Specify one or two announcements played to caller. This affects announcements system wide).
Announcement Trunk Group Set Up Screen 2.1.5.1 (Trunk Type=OGT, Connection
Class=TKTH).
Microtel GTD-5
PABX
Signal
Announcer
Signal
Line 1
Pin-
Color
Line 2
Pin-
Color
Line 3
Pin-
Color
Line 4
Pin-
Color
Line 5
Pin-
Color
Line 6
Pin-
Color
Line 7
Pin-
Color
Line 8
Pin-
Color
Ring
Tip
Ring
Tip
Battery* Start-
C
SSG
Start+
CP1
1 -
Blu/Wht
4 -
Brn/Wht
7 -
Org/Red
10 -
Slt/Red
26 -
Wht/Blu
28 -
Wht/Grn
29 -
Wht/Brn
31 -
Red/Blu
3 -
Grn/Wht
27 -
Wht/Org
6 -
Blu/Red
30 -
Wht/Slt
32 -
Red/Org
34 -
Red/Brn
9 -
Brn/Red
33 -
Red/Grn
35 -
Red/Slt
37 -
Blk/Org
12 -
Org/Blk
36 -
Blk/Blu
13 -
Grn/Blk
16 -
Blu/Yel
38 -
Blk/Grn
40 -
Blk/Slt
41 -
Yel/Blu
43 -
Yel/Grn
15 -
Slt/Blk
39 -
Blk/Brn
18 -
Grn/Yel
42 -
Yel/Org
19 -
Brn/Yel
44 -
Yel/Brn
46 -
Vlt/Blu
21 -
Blu/Vlt
45 -
Yel/Slt
22 -
Org/Vlt
47 -
Vlt/Org
49 -
Vlt/Brn
24 -
Brn/Vlt
48 -
Vlt/Grn
E CP2 2 -
Org/Wht
5 -
Slt/Wht
8 -
Grn/Red
11 -
Blu/Blk
14 -
Brn/Blk
17 -
Org/Yel
20 -
Slt/Yel
23 -
Grn/Vlt
PBX Operation Mode: Pulse Start/Level Return Multiple Play (PS/LR MP NO). See
About XMU+ Operating Modes on page
Connect SSG lead to system ground.
XMU+ Installation and Maintenance Guide rev.07
63
Common Interface Tables (By Application)
Microtel Omni
PABX
Signal
Announcer
Signal
Line 1
Pin-
Color
Line 2
Pin-
Color
Line 3
Pin-
Color
Line 4
Pin-
Color
Line 5
Pin-
Color
Line 6
Pin-
Color
Line 7
Pin-
Color
Line 8
Pin-
Color
Ring
Tip
M
Ground* Start+
E
Ring
Tip
Start-
CP1
1 -
Blu/Wht
26 -
Wht/Blu
28 -
Wht/Grn
3 -
Grn/Wht
27 -
Wht/Org
4 -
Brn/Wht
7 -
Org/Red
29 -
Wht/Brn
31 -
Red/Blu
32 -
Red/Org
34 -
Red/Brn
6 -
Blu/Red
30 -
Wht/Slt
9 -
Brn/Red
33 -
Red/Grn
10 -
Slt/Red
35 -
Red/Slt
37 -
Blk/Org
12 -
Org/Blk
36 -
Blk/Blu
13 -
Grn/Blk
38 -
Blk/Grn
40 -
Blk/Slt
15 -
Slt/Blk
39 -
Blk/Brn
16 -
Blu/Yel
41 -
Yel/Blu
43 -
Yel/Grn
18 -
Grn/Yel
42 -
Yel/Org
19 -
Brn/Yel
44 -
Yel/Brn
46 -
Vlt/Blu
21 -
Blu/Vlt
45 -
Yel/Slt
22 -
Org/Vlt
47 -
Vlt/Org
49 -
Vlt/Brn
24 -
Brn/Vlt
48 -
Vlt/Grn
Ground* CP2 2 -
Org/Wht
5 -
Slt/Wht
8 -
Grn/Red
11 -
Blu/Blk
14 -
Brn/Blk
17 -
Org/Yel
20 -
Slt/Yel
more information.
23 -
Grn/Vlt
NEC NEAX2400
PABX
Signal
Announcer
Signal
Line 1
Pin-
Color
Line 2
Pin-
Color
Line 3
Pin-
Color
Line 4
Pin-
Color
Line 5
Pin-
Color
Line 6
Pin-
Color
Line 7
Pin-
Color
Line 8
Pin-
Color
Ring
Tip
M
Ring
Tip
Start-
1 -
Blu/Wht
4 -
Brn/Wht
7 -
Org/Red
10 -
Slt/Red
26 -
Wht/Blu
28 -
Wht/Grn
29 -
Wht/Brn
31 -
Red/Blu
32 -
Red/Org
34 -
Red/Brn
35 -
Red/Slt
37 -
Blk/Org
13 -
Grn/Blk
16 -
Blu/Yel
38 -
Blk/Grn
40 -
Blk/Slt
41 -
Yel/Blu
43 -
Yel/Grn
19 -
Brn/Yel
44 -
Yel/Brn
46 -
Vlt/Blu
22 -
Org/Vlt
47 -
Vlt/Org
49 -
Vlt/Brn
Ground Start+ 3 -
Grn/Wht
6 -
Blu/Red
9 -
Brn/Red
12 -
Org/Blk
15 -
Slt/Blk
18 -
Grn/Yel
21 -
Blu/Vlt
24 -
Brn/Vlt
PBX Operation Mode: Level Start/Pulse Return Single Play (LS/PR SP NO). See
About XMU+ Operating Modes on page 68
for more information.
Set the switches on the TLT circuit board as follows:
Switch 00 - EM
Switch 10 - 600Ω
Switch 20 - Ground Idle
Switch 01 - EM
Switch 11 - 600Ω
Switch 21 - Ground Idle
Connect announcer to NEC 4TLT - Loop and Tie-Line Interface Circuit Card.
Switch 02 - EM
Switch 12 - 600Ω
Switch 22 - Ground Idle
Switch 03 - EM
Switch 13 - 600Ω
Switch 23 - Ground Idle
64 Chapter 6
Cabling the XMU+
Nortel SL-1
®
or Meridian-1
®
(option 1), DMS-100,
SL-100, CS1000 and Centrex
The Low Impedance option is required when 4 to 24 RAN trunks are connected in parallel to a single channel.
PABX
Signal
Announcer
Signal
Line 1
Pin-
Color
Line 2
Pin-
Color
Line 3
Pin-
Color
Line 4
Pin-
Color
Line 5
Pin-
Color
Line 6
Pin-
Color
Line 7
Pin-
Color
Line 8
Pin-
Color
Ring
Tip
CP/E
Ring
Tip
CP1
1 -
Blu/Wht
26 -
Wht/Blu
27 -
Wht/Org
4 -
Brn/Wht
7 -
Org/Red
10 -
Slt/Red
29 -
Wht/Brn
30 -
Wht/Slt
32 -
Red/Org
33 -
Red/Grn
35 -
Red/Slt
36 -
Blk/Blu
13 -
Grn/Blk
16 -
Blu/Yel
38 -
Blk/Grn
39 -
Blk/Brn
41 -
Yel/Blu
42 -
Yel/Org
19 -
Brn/Yel
44 -
Yel/Brn
45 -
Yel/Slt
22 -
Org/Vlt
47 -
Vlt/Org
48 -
Vlt/Grn
Ground CP2 2 -
Org/ Wht
5 -
Slt/Wht
8 -
Grn/Red
11 -
Blu/Blk
14 -
Brn/Blk
17 -
Org/Yel
20 -
Slt/Yel
23 -
Grn/Vlt
Meridian-1: Connect announcer to NT8D14 Universal Trunk Card or NT5K19 or NT5K72AA. Configure Meridian-1 for an
Audichron Announcer. IMPORTANT: Do not connect MB lead. Software must be downloaded to card by
disabling, then re-enabling card
SL-1:
DMS:
Connect announcer to QP C74 Recorded Announcement Circuit Pack. Configure SL-1 for an Audichron
Announcer.
Connect announcer to NT2X72AA Card. Configure DMS for an Audichron Announcer. Connect announcer’s
Tip and Ring to the NT2X72AA card’s Tip 1 and Ring 1.
Northern Telecom SL-1
®
or Meridian-1
®
(option 2)
The Low Impedance option is required when 4 to 24 RAN trunks are connected in parallel to a single channel
PABX
Signal
Announcer
Signal
Line 1
Pin-
Color
Line 2
Pin-
Color
Line 3
Pin-
Color
Line 4
Pin-
Color
Line 5
Pin-
Color
Line 6
Pin-
Color
Line 7
Pin-
Color
Line 8
Pin-
Color
Ring
Tip
Start/
MB
CP
Ring
Tip
Battery* Start-
Start+
CP1
1 -
Blu/Wht
4 -
Brn/Wht
7 -
Org/Red
10 -
Slt/Red
26 -
Wht/Blu
28 -
Wht/Grn
29 -
Wht/Brn
31 -
Red/Blu
3 -
Grn/Wht
27 -
Wht/Org
6 -
Blu/Red
30 -
Wht/Slt
32 -
Red/Org
34 -
Red/Brn
9 -
Brn/Red
33 -
Red/Grn
35 -
Red/Slt
37 -
Blk/Org
12 -
Org/Blk
36 -
Blk/Blu
13 -
Grn/Blk
16 -
Blu/Yel
38 -
Blk/Grn
40 -
Blk/Slt
41 -
Yel/Blu
43 -
Yel/Grn
15 -
Slt/Blk
39 -
Blk/Brn
18 -
Grn/Yel
42 -
Yel/Org
19 -
Brn/Yel
44 -
Yel/Brn
46 -
Vlt/Blu
21 -
Blu/Vlt
45 -
Yel/Slt
22 -
Org/Vlt
47 -
Vlt/Org
49 -
Vlt/Brn
24 -
Brn/Vlt
48 -
Vlt/Grn
Ground CP2 2 -
Org/Wht
5 -
Slt/Wht
8 -
Grn/Red
11 -
Blu/Blk
14 -
Brn/Blk
17 -
Org/Yel
20 -
Slt/Yel
23 -
Grn/Vlt
PBX Operation Mode: Pulse Start/Level Return (PS/LR NO). See
About XMU+ Operating Modes on page 68 for more
information.
Meridian-1: Connect announcer to QPC74 Recorded Announcement Circuit Pack or NT8D14BA (or later) Universal Trunk
Card or NT5K19 or NT5K72AA. Software release X19 (or later) must be used when connecting to the Universal Trunk
Card.
Configure Meridian-1 for a Cook Electric 201 Announcer. Software must be down be downloaded to card by disabling, then re-enabling card.
XMU+ Installation and Maintenance Guide rev.07
65
Common Interface Tables (By Application)
PABX
Signal
Announcer
Signal
Line 1
Pin-
Color
Line 2
Pin-
Color
Line 3
Pin-
Color
Line 4
Pin-
Color
Line 5
Pin-
Color
Line 6
Pin-
Color
Line 7
Pin-
Color
SL-1: Connect announcer to QPC74 Recorded Announcement Circuit Pack. Configure SL-1 for a Cook Electric 201
Announcer.
Line 8
Pin-
Color
ROLM 9200
PABX
Signal
Announcer
Signal
Line 1
Pin-
Color
Line 2
Pin-
Color
Line 3
Pin-
Color
Line 4
Pin-
Color
Line 5
Pin-
Color
Line 6
Pin-
Color
Line 7
Pin-
Color
Line 8
Pin-
Color
Ring
Tip
M
SG
E
Ring
Tip
Start-
Start+
CP1
1 -
Blu/Wht
26 -
Wht/Blu
28 -
Wht/Grn
3 -
Grn/Wht
27 -
Wht/Org
4 -
Brn/Wht
7 -
Org/Red
29 -
Wht/Brn
31 -
Red/Blu
32 -
Red/Org
34 -
Red/Brn
6 -
Blu/Red
30 -
Wht/Slt
9 -
Brn/Red
33 -
Red/Grn
10 -
Slt/Red
35 -
Red/Slt
37 -
Blk/Org
12 -
Org/Blk
36 -
Blk/Blu
13 -
Grn/Blk
38 -
Blk/Grn
40 -
Blk/Slt
15 -
Slt/Blk
39 -
Blk/Brn
16 -
Blu/Yel
41 -
Yel/Blu
43 -
Yel/Grn
18 -
Grn/Yel
42 -
Yel/Org
19 -
Brn/Yel
44 -
Yel/Brn
46 -
Vlt/Blu
21 -
Blu/Vlt
45 -
Yel/Slt
22 -
Org/Vlt
47 -
Vlt/Org
49 -
Vlt/Brn
24 -
Brn/Vlt
48 -
Vlt/Grn
Battery CP2 2 -
Org/Wht
5 -
Slt/Wht
8 -
Grn/Red
11 -
Blu/Blk
14 -
Brn/Blk
17 -
Org/Yel
20 -
Slt/Yel
23 -
Grn/Vlt
information.
Strap SB lead to Battery.
Siemens Saturn
PABX
Signal
Announcer
Signal
Line 1
Pin-
Color
Line 2
Pin-
Color
Line 3
Pin-
Color
Line 4
Pin-
Color
Line 5
Pin-
Color
Line 6
Pin-
Color
Line 7
Pin-
Color
Line 8
Pin-
Color
Ring
Tip
Ring
Tip
Battery* Start-
EB & MB Start+
1 -
Blu/Wht
4 -
Brn/Wht
26 -
Wht/Blu
29 -
Wht/Brn
7 -
Org/Red
10 -
Slt/Red
32 -
Red/Org
35 -
Red/Slt
28 -
Wht/Grn
3 -
Grn/Wht
31 -
Red/Blu
6 -
Blu/Red
34 -
Red/Brn
9 -
Brn/Red
37 -
Blk/Org
12 -
Org/Blk
13 -
Grn/Blk
16 -
Blu/Yel
38 -
Blk/Grn
41 -
Yel/Blu
40 -
Blk/Slt
15 -
Slt/Blk
43 -
Yel/Grn
18 -
Grn/Yel
19 -
Brn/Yel
44 -
Yel/Brn
46 -
Vlt/Blu
21 -
Blu/Vlt
22 -
Org/Vlt
47 -
Vlt/Org
49 -
Vlt/Brn
24 -
Brn/Vlt
EA CP1 27 -
Wht/Org
30 -
Wht/Slt
33 -
Red/Grn
36 -
Blk/Blu
39 -
Blk/Brn
42 -
Yel/Org
45 -
Yel/Slt
48 -
Vlt/Grn
Ground* CP2 2 -
Org/Wht
5 -
Slt/Wht
8 -
Grn/Red
11 -
Blu/Blk
14 -
Brn/Blk
17 -
Org/Yel
20 -
Slt/Yel
23 -
Grn/Vlt
PBX Operation Mode: Pulse Start/Level Return (PS/LR NC). See
About XMU+ Operating Modes on page 68 for more
information.
Connect announcer to E&M Trunk Card.
66 Chapter 6
Cabling the XMU+
Solid State Junior and Senior Executive
PABX
Signal
Announcer
Signal
Line 1
Pin-
Color
Line 2
Pin-
Color
Line 3
Pin-
Color
Line 4
Pin-
Color
Line 5
Pin-
Color
Line 6
Pin-
Color
Line 7
Pin-
Color
Line 8
Pin-
Color
Ring
Tip
Ring
Tip
M Sync CP1
1 -
Blu/Wht
26 -
Wht/Blu
27 -
Wht/Org
4 -
Brn/Wht
29 -
Wht/Brn
30 -
Wht/Slt
7 -
Org/Red
32 -
Red/Org
33 -
Red/Grn
10 -
Slt/Red
35 -
Red/Slt
36 -
Blk/Blu
13 -
Grn/Blk
38 -
Blk/Grn
39 -
Blk/Brn
16 -
Blu/Yel
41 -
Yel/Blu
42 -
Yel/Org
19 -
Brn/Yel
44 -
Yel/Brn
45 -
Yel/Slt
22 -
Org/Vlt
47 -
Vlt/Org
48 -
Vlt/Grn
Ground CP2 2 -
Org/Wht
5 -
Slt/Wht
8 -
Grn/Red
11 -
Blu/Blk
14 -
Brn/Blk
17 -
Org/Yel
20 -
Slt/Yel
23 -
Grn/Vlt
information.
MOH Applications
The following table describes the cabling of MOH line cards to a PBX. See
MOH line cards on page 55 for more information.
PABX Signal Input 1 Input 2 Output 1 Output 2 Output 3 Output 4
External
External
MOH Input
MOH Input grn red grn red grn red grn red grn red grn red
XMU+ Installation and Maintenance Guide rev.07
67
Common Interface Tables (By Application)
MWR Applications
The following table describes the cabling of MWR line cards to a transmitter. See
To cable MWR line cards on page 55 for more information.
Line 1
Pin-
Color
Line 2
Pin-
Color
Line 3
Pin-
Color
Line 4
Pin-
Color
Line 5
Pin-
Color
Line 6
Pin-
Color
Line 7
Pin-
Color
Line 8
Pin-
Color
Audio
Audio
Keying
(GND)
Keying
(20+ Vdc)
Ring
Tip
CP1
CP2
1 -
Blu/Wht
26 -
Wht/Blu
27 -
Wht/Org
2 -
Org/Wht
4 -
Brn/Wht
29 -
Wht/Brn
30 -
Wht/Slt
5 -
Slt/Wht
7 -
Org/Red
32 -
Red/Org
33 -
Red/Grn
8 -
Grn/Red
10 -
Slt/Red
35 -
Red/Slt
36 -
Blk/Blu
11 -
Blu/Blk
13 -
Grn/Blk
38 -
Blk/Grn
39 -
Blk/Brn
14 -
Brn/Blk
16 -
Blu/Yel
41 -
Yel/Blu
42 -
Yel/Org
17 -
Org/Yel
19 -
Brn/Yel
44 -
Yel/Brn
45 -
Yel/Slt
20 -
Slt/Yel
22 -
Org/Vlt
47 -
Vlt/Org
48 -
Vlt/Grn
23 -
Grn/Vlt
68 Chapter 6
Cabling the XMU+
About XMU
+
Operating Modes
XMU+ operating modes are PBX dependent. They determine the specific way XMU+ lines behave when communicating with a PBX. See the XMU+ QuickStart Guide for more information about operating modes.
If required, determine the appropriate operating mode (listed below) and set the PBX line card to that operating mode. The Control Pulse (CP) relay in the following diagrams can be configured for Normally Open (NO) or Normally Closed (NC) during message play.
Continuous Play (CP)
The message plays continuously to the line, independent of what is happening on other lines.
The CP contacts toggle position for approximately
250 msec. at the start of the message.
Synchronized
Continuous Play
(SCP)
The message plays continuously to the line.
All lines begin playing the message(s) at the same time. The CP contacts toggle position for approximately 500 msec. at the start of the message(s).
Level Start/Pulse
Return - Single Play
(LS/PR-SP)
The message plays in response to a start signal.
The CP contacts toggle position for approximately
250 msec. at the start and end of the message. The message stops playing if the start signal is removed.
Level Start/Pulse
Return - Multiple
Play (LS/PR-MP)
The message plays in response to a start signal.
The CP contacts toggle position for approximately
250 msec. at the start and end of the message. The message stops playing if the start signal is removed.
The message plays repeatedly until the start signal is removed.
Level Start/Level
Return - Single Play
(LS/LR-SP)
The message plays in response to a start signal.
The CP contacts toggle position while the message is playing. The message stops playing if the start signal is removed.
XMU+ Installation and Maintenance Guide rev.07
69
About XMU+ Operating Modes
70 Chapter 6
Cabling the XMU+
Pulse Start/Level
Return (PS/LR)
The message plays in response to a start signal.
The CP contacts toggle position while the message is playing.
Pulse Start/Pulse
Return (PS/PR)
The message plays in response to a start signal.
The CP contacts toggle position for approximately
250 msec. at the end of the message.
Ring Start (R)
The message plays in response to a Loop or Ground Start signal. The message will stop playing, before completion, if loop current is removed from the line.
Ring Start without Loop Current Check (RN)
The message plays in response to a Loop or Ground Start signal. The line will not disconnect until the message has played out completely.
Ring Start/Tone Disconnect (RT)
Will disconnect after 4 sec of continuous tone (RT+ is less sensitive to far-end noise).
Ring Start/DTMF Disconnect (RD)
Will disconnect on A, B, C or D.
XMU+ Installation and Maintenance Guide rev.07
71
About XMU+ Operating Modes
Ring Start/Busy Disconnect (RB)
Will disconnect on two cycles of busy tone. (RB+ will disconnect after four cycles of busy tone.)
Ring Start/Quick Answer (RQ)
Line is answered 1/10 second after first ring cycle.
Ring Immediate (RI)
Only available with T1, line is answered after 1/4 second.
72 Chapter 6
Cabling the XMU+
Understanding XMU
+
Navigation
In order to properly test XMU+ installation, you must understand the options XMU+ offers for navigation and configuration, including:
The XMU+ Front Panel. See
Understanding the XMU+ Front Panel on page 81.
XMUCOM+ software. See XMU+ QuickStart Guide.
Remote XMU+ access. See Understanding XMU+ Remote Telephone
Using Remote Telephone Access on page 88.
As well, you should gain a brief understanding of the XMU+ firmware hierarchy in order to easily navigate through the XMU+ Front Panel.
Firmware is the software that is hard-coded into the XMU+ Control card and the various line cards. See
Understanding the XMU+ Firmware
In this chapter...
XMU+ Navigation Activities on page 75.
Understanding the XMU+ Firmware Hierarchy on page 76.
Understanding the XMU+ Front Panel on page 81.
Understanding XMU+ Remote Telephone Access on page 85.
7
74 Chapter 7
Understanding XMU+ Navigation
XMU+ Installation and Maintenance Guide rev.07
75
XMU+ Navigation Activities
XMU+ Navigation Activities
Complete the following activities to understand XMU+ navigation and to prepare for setting up configurations:
Understanding XMU+ Navigation
Understand Firmware
Hierarchy
Understand Front
Panel Navigation
Using the
Front Panel
Understand Remote
Access Navigation
Configuring and Using
Remote Access
1.
2.
3.
Understand the XMU+ hierarchy. See
Understanding the XMU+ Firmware
Hierarchy on page 76 for more information.
Understand Front Panel navigation, and learn to configure the XMU+ using the
Front Panel. See the following for more information:
Understanding the XMU+ Front Panel on page 81.
Using the Front Panel on page 82
If required, configure the XMU+ to allow Remote Access and learn to navigate using Remote Access. See the following for more information
Understanding XMU+ Remote Telephone Access on page 85.
Using Remote Telephone Access on page 88.
76 Chapter 7
Understanding XMU+ Navigation
Understanding the XMU
+
Firmware Hierarchy
Firmware is the software that is hard-coded into XMU+ control and line cards. You should gain a brief understanding of the XMU+ firmware hierarchy in order to navigate through the XMU+ configuration menu displayed on the Front Panel of the XMU+.
About Partitions
The XMU+ is often set up for a single user (single partition mode), who uses it as a single, large, call processing system. However, when the XMU+ is set up in multiple partition mode in a shared environment, the XMU+ is turned into several virtual systems, with each partition acting as an individual unit. The number of partitions that the XMU+ can be set up for (up to 64) is limited only by the amount of recording time installed.
To determine whether your XMU+ unit is configured for single or multiple partitions, see
To check for system partitioning on page 84.
For more information, see:
Main Menu Hierarchy - Single Partition Mode on page 76.
Main Menu Hierarchy - Multiple Partition Mode on page 79.
Main Menu Hierarchy - Single Partition Mode
When the XMU+ is operating in Single Partition mode, the following configuration structure represents the Front Panel Main Menu, from which all configuration commands originate. There are four Main Menu categories in the XMU+ firmware:
Messages - used to record, delete or play messages.
See Message Menu Hierarchy - Single Partition Mode on page 77 for more
information.
Cards - used for card setup and Starting Node.
See Card Menu Hierarchy - Single Partition Mode on page 77 for more information.
Nodes - used to create the call flow.
See Node Menu Hierarchy - Single Partition Mode on page 78 for more information.
System - Used to define system parameters, settings and maintenance.
See Node Menu Hierarchy - Single Partition Mode on page 78 for more information.
XMU+ Installation and Maintenance Guide rev.07
77
Understanding the XMU+ Firmware Hierarchy
Message Menu Hierarchy - Single Partition Mode
Many XMU+ message capabilities are accessed from the Front Panel. Using the Front
Panel, users can:
Play, record and, delete messages.
View message details.
Control when and how messages are played.
The following configuration structure represents the Front Panel message menu when
XMU+ is operating in Single Partition mode:
Card Menu Hierarchy - Single Partition Mode
Users can view line card information from the Front Panel by navigating through the card menu hierarchy. The following configuration structure represents the Front
Panel card menu when XMU+ is operating in Single Partition mode:
78 Chapter 7
Understanding XMU+ Navigation
Node Menu Hierarchy - Single Partition Mode
XMU+ configurations control the behavior and functionality of XMU+. Nodes are used to program and define these configuration files. Users can view information about each node by navigating through the node menu hierarchy. See XMU+
QuickStart Guide for more information about nodes.
The following configuration structure represents the Front Panel node menu when the
XMU+ is operating in Single Partition mode:
System Menu Hierarchy - Single Partition Mode
XMU+ system access codes, communication protocols, and system details and status can all be viewed by navigating through the card menu hierarchy on the Front Panel.
However, XMUCOM+ also provides an easy-to-use interface for setting, changing, and viewing these parameters. See XMU+ QuickStart Guide for more information about system configuration.
The following configuration structure represents the Front Panel system menu when the XMU+ is operating in Single Partition mode:
XMU+ Installation and Maintenance Guide rev.07
79
Understanding the XMU+ Firmware Hierarchy
Main Menu Hierarchy - Multiple Partition Mode
When the XMU+ is operating in Multiple Partition mode, the following configuration structure represents the Front Panel Main Menu, from which all configuration commands originate. There are three Main Menu categories in the XMU+ firmware:
Cards - used for card setup and Starting Node.
See Card Menu Hierarchy - Multiple Partition Mode on page 79 for more
information.
System - Used to define system parameters, settings and maintenance.
See Card Menu Hierarchy - Multiple Partition Mode on page 79 for more
information.
Partition - Used to create, delete, and modify partition parameters. See Partition
Menu Hierarchy - Multiple Partition Mode on page 80 for more information.
Note: In the single partition hierarchy, messages and nodes are top-level options. In the multiple partition hierarchy, message and node configuration options are dependent on the partition selected, and are therefore found under the main partition menu.
Card Menu Hierarchy - Multiple Partition Mode
Users can view card information and details from the Front Panel by navigating through the card menu hierarchy. Card is a top-level menu option, since line card options are independent of XMU+ partitions.
The configuration structure of the Front Panel system menu when XMU+ is operating in Multiple Partition mode is exactly the same as the menu displayed in Single
Partition mode. See
Card Menu Hierarchy - Single Partition Mode on page 77 for more
information.
80 Chapter 7
Understanding XMU+ Navigation
System Menu Hierarchy - Multiple Partition Mode
XMU+ system status, details, access codes, and communication protocols can all be viewed by navigating through the system menu hierarchy on the Front Panel.
The configuration structure of the Front Panel system menu when XMU+ is operating in Multiple Partition mode is exactly the same as the menu displayed when XMU+ is operating in Single Partition mode. See
System Menu Hierarchy - Single Partition
Mode on page 78 for more information
Partition Menu Hierarchy - Multiple Partition Mode
Partition parameters, including message and node options, can all be viewed by navigating through the card menu hierarchy on the Front Panel.
The following configuration structure represents the Front Panel partition menu when the XMU+ is operating in Multiple Partition mode:
XMU+ Installation and Maintenance Guide rev.07
81
Understanding the XMU+ Front Panel
Understanding the XMU
+
Front Panel
The XMU+ can be configured by using the four buttons and the LCD located on the
Front Panel, as shown below.
The Front Panel buttons are used to navigate through the XMU+ configuration menu that is shown on the LCD (display). The menu is arranged in a top-down flow.
This feature...
2 x 16 LCD character display
Arrows
Enter
Exit
Is used to...
Display function information and line status to the user.
Navigate to the various XMU+ menu options.
Select a menu option or to navigate to a deeper level of the menu.
Navigate back up the menu.
Note: XMU+ can also be managed and configured with XMUCOM+ software. This software provides an intuitive, easy-to-use interface for designing and changing XMU+ configurations, and for completing XMU+ administrative functions. See the XMU+
QuickStart Guide for more information.
82 Chapter 7
Understanding XMU+ Navigation
Using the Front Panel
The LCD (display) shows two 16-digit lines. The top line of the display shows the main program category, while the bottom line shows one of the possible selections in that category. An arrow (< or >) on the left or right edge of the display indicates that there is another possible selection in the direction shown.
For example, you are configuring message # 1 if you see the display to the right:
You have the following options in this case:
1.
Access additional selections by pressing the right arrow button. There are no selections available by pressing the left arrow button.
2.
Select the option that appears on the display (Play) by pressing the Enter button.
3.
Exit this display by pressing the Exit button.
Certain menu items require the selection of a number, for example message index number, as shown in the display to the right:
You have the following options in this case:
1.
Press the right arrow key to display the next message number.
2.
3.
Press the left arrow key to display the previous message number.
Press enter to select the current message.
Note: See
Understanding the XMU+ Firmware Hierarchy on page 76 to view the Front Panel
programming tree.
TIP...
To pause while recording, press
Enter. To resume recording, press
Enter again.
XMU+ Installation and Maintenance Guide rev.07
83
Understanding the XMU+ Front Panel
7.
8.
2.
3.
4.
To record a message
1.
Connect a handset (included with the XMU+) or tapedeck to the XMU+ unit.
Press Enter to access the Main Menu.
Press Enter to select Messages.
Press the Right Arrow button until you reach the desired message number and press Enter.
5.
Press the Right Arrow button until you reach Record and press Enter.
6.
Press Enter (again) to begin recording your message.
XMU+ monitors your recording time.
Press Exit to stop recording.
Press Exit until the menu returns to the main display.
TIP...
To pause while playing, press Enter.
To resume playing, press Enter again.
5.
6.
2.
3.
4.
To play a message
1.
Connect a handset (included with the XMU+) to the
XMU+ unit.
Press Enter to access the Main Menu.
Press Enter to select Messages.
Press the Right Arrow button until you reach the desired message number and press Enter.
Press Enter to select Play on the menu.
Press Enter (again) to play the message.
XMU+ plays the message, counting-down the remaining playing time of the message.
7.
Press Exit to stop playing (or allow the message to play itself out).
8.
Press Exit until the menu returns to the main display.
84 Chapter 7
Understanding XMU+ Navigation
TIP...
To cancel the delete command and return to the previous menu, press Exit when XMU+ asks Are you sure?.
5.
6.
To delete a message
1.
2.
3.
Press Enter to access the Main Menu.
Press Enter to select Messages.
Press the Right Arrow button until you reach the desired message number and press Enter.
4.
Press the Right Arrow button until you reach Delete and press Enter.
XMU+ displays a message asking if you are sure that you want to delete this message.
Press Enter to delete the message.
When XMU+ re-displays Message # <Delete>, press Exit until the menu returns to the main display.
To check for system partitioning
5.
6.
1.
2.
All XMU+ units have a partitioning option. Multi-partitioning enables the XMU+ to function as multiple units. It is a good idea to determine whether or not multipartitioning is enabled before you begin to configure the XMU+.
Press Enter to access the Main Menu.
Press the Right Arrow until you reach System on the
Main Menu, and press Enter.
3.
Press the Right Arrow until you reach Partition on the
Main Menu, and press Enter.
4.
Press Enter to select Multi partition.
XMU+ displays a YES message if multi-partitioning is enabled, and a NO message if it is disabled.
Press Exit until the menu returns to the main display.
Record whether multi-partitioning is enabled (YES) or disabled (NO) on the Delivery Checklist. See
Delivery Checklist on page 21.
XMU+ Installation and Maintenance Guide rev.07
85
Understanding XMU+ Remote Telephone Access
Understanding XMU
+
Remote Telephone Access
The Remote Access feature allows a programmer to access XMU+ from a remote location using a touch-tone telephone. When the programmer presses the touch-tone keys, the
XMU+ receives a DTMF tone and responds with voice prompts that instruct the programmer on how to proceed.
When a user accesses the XMU+ remotely, the XMU+ responds immediately with a request for an access code. The manner in which the XMU+ responds from that point on depends on the access code entered, and whether the XMU+ is operating in Single Partition mode or
Multiple Partition mode.
When XMU+ is operating in Single Partition mode:
Entering this access code...
Allows...
System
Message
Specifications...
Administrators access to all levels of XMU+ features and options.
This number is unique from all other
XMU+ access codes.
Users access to specific messages in the XMU+.
A message access code only allows changes to messages with that access code assigned to it.
Each message in the XMU+ can be assigned an access code. If the user enters a message specific access code via remote access, then they do not have to enter the message number and # when using the record, play, or replace functions.
This code can be shared by one or more messages. Message access codes cannot be the same as the
System access codes.
When XMU+ is operating in Multiple Partition mode:
Entering this access code...
Allows...
Specifications...
System
Partition
Administrators to have access to all levels of features and options in all XMU+ partitions.
This number is unique from all other XMU+ access codes.
Users access to a particular partition. When the user enters a partition access code,
XMU+ selects that partition automatically.
This number is unique to each partition.
Once a partition access code is entered, the system does not accept or require message access codes to be used.
For example:
Partition 1: 0101
Partition 2: 0202 etc.
86 Chapter 7
Understanding XMU+ Navigation
Setting Up XMU
+
Remote Telephone Access (optional)
If Remote Access will be used to communicate with the XMU+, the unit must be:
1.
Cabled to a telephone line. See
Connecting Remote Telephone Access (optional)
2.
Set XMU+ to Remote Access mode using the XMU+ Front Panel.
See To set XMU+ Remote Telephone Access mode on page 86.
3.
Programmed with a Remote Access code using the XMU+ Front Panel.
(optional). See
To change the default Remote Telephone Access code on page 87.
To set XMU
+
Remote Telephone Access mode
5.
6.
Remote access mode is set to Ring Start (R) by default, and is rarely changed.
1.
Press Enter to access the Main Menu.
2.
Press the Right Arrow (three times) until you reach System on the Main Menu, and press Enter.
3.
Press the Right Arrow until you reach Remote Mode, and press Enter.
4.
Press the Right Arrow until you reach the desired remote mode, and press Enter. You can choose from the following options:
R - Ring start with loop/shunt disconnect (default).
RD - Ring start with DTMF disconnect.
RB - Ring start with busy tone disconnect.
RT - Ring start with dial tone disconnect.
RQ - Ring start with quick answer.
Press Exit until the menu returns to the main display.
Record the Remote Access mode on the Delivery Checklist. See
Delivery Checklist on page 21.
XMU+ Installation and Maintenance Guide rev.07
87
Understanding XMU+ Remote Telephone Access
To change the default Remote Telephone Access code
Assigning a new, unique access code to each XMU+ is recommended to prevent unauthorized telephone access to your system.
8.
9.
4.
5.
6.
1.
2.
If multi-partitioning is enabled, a unique Remote Access code is required for each partition in addition to the System code. See
To check for system partitioning on page
84 and the XMU+ QuickStart Guide for more information about multiple access codes.
Press Enter to access the Main Menu.
Press the Right Arrow (three times) until you reach System on the Main Menu, and press Enter.
3.
Press Enter, hit the right arrow key & Enter to select Access
Codes.
Press Enter to select Remote Access.
Press Enter to select the first digit in the existing access code.
Use the Right Arrow or Left Arrow to select a new Remote
Access code digit, and press Enter.
7.
Repeat Step 6 until the new access code is entered.
Access codes must have a minimum of 4 and a maximum of 8 digits.
Press Exit until the menu returns to the main display.
Record the new Remote Access code on the Delivery Checklist.
See The XMU+ Delivery Checklist on page 21.
88 Chapter 7
Understanding XMU+ Navigation
Using Remote Telephone Access
There are many reasons to use Remote Telephone Access on the XMU+, including:
Ease of use by users who are accustomed to making touch-tone keypad commands.
Crisp, clear messages, since the background noise from other equipment in a COMS room is eliminated.
Access to the XMU+ from any location.
Every remote access session starts with the user entering a Remote Access security code.
See Understanding XMU+ Remote Telephone Access on page 85 for more information
about Remote Telephone Access codes.
Once the code has been verified by XMU+, the various activities listed on the next page can be completed by entering the appropriate remote telephone access command. There are two ways to enter remote telephone access commands - Interactive and Direct.
With this Type of Command...
The user enters...
For example, to play a message...
Interactive
Direct
A single digit command, immediately followed by #.
Pressing # indicates the end of a command to the XMU+.
If required, the system then prompts the user to the next step or option, where they again enter the command and #.
A multi-level command, immediately followed by #.
The direct entry method allows advanced users to enter commands quickly, without waiting for a prompt from the XMU+. Pressing # indicates the end of a command to the XMU+.
Enter 8#. The XMU+ then prompts Enter Message
Number.
Enter the nnn # (where nnn is the message number). The
XMU+ then prompts the user to the next step or option.
The XMU+ will give the user
10 seconds to enter the message number.
Enter 8 nnn #(where nnn is the message number.)
The XMU+ then prompts the user to the next step or option.
Note: Once a digit is pressed, additional digits must be entered within 2 seconds, or the XMU+ will automatically terminate the entry.
Pressing # at any time during an entry will terminate the entry.
XMU+ Installation and Maintenance Guide rev.07
89
Understanding XMU+ Remote Telephone Access
Remote Telephone Access Commands
To do this...
Use this Interactive
Command...
Or this Direct
Command...
Record Message
Record Standby Message+
Play Message
Replace Message
7#, then nnn#
7#, then 0#
8#, then nnn#
9#, then nnn#
Delete Message
Delete Messages in a List Node
Change System Access code
39# then nnn#
51# then nnn#
Change Partition Access code using System Access code*
Change Partition Access code*
Change Message Access code**
Obtain Line Counts
Switch Partition*
1#, then 0#
(administrators only)
1#, then nnn#
(administrators only)
Obtain line counts for all lines on a card
Clear all line counts
Terminate Remote Access and
Restart
-
-
Disconnect 0#
Change Remote Access Language -
1#
1#, then nnn#
2#, then xy
-
2#, then x, then 0
Change Partitions*
Turns message on
Turn message off
Override Enabled
Override Disabled
-
31#, then nnn#
30#, then nnn#
-
-
0#
4z#
0nnn#
31nnn#
30nnn#
591#
590#
7nnn#
70#
8nnn#
9nnn#
39nnn#
51nnn#
10#
(administrators only)
1nnn#
(administrators only)
1#
1nnn#
2xy#
0nnn#
2x0#
299#
00#
Note: nnn = partition, message, or access code number x = card number, y = line number, z = language number
* = only available with partitioning enabled
** = only available with partitioning disabled
+ = Message number ‘0’ is a temporary message (Standby Message), which can be
recorded and played without affecting any other messages. When the user decides that the temporary message is recorded properly, they can replace any message in the XMU+ with the temporary message. When the user disconnects, the temporary message is automatically erased.
90 Chapter 7
Understanding XMU+ Navigation
Working with Remote Telephone Access Messages
Users wanting to add, remove, or change a message remotely must have a good understanding of the configuration and messages in the XMU+. The user must also know the message number associated with each message they want to work with. This information is collected during configuration design and implementation. See the
XMU+ QuickStart Guide for more information about messages.
To remotely access the XMU+
1.
Dial the Remote Access telephone number. See
Physical Specifications on page
21 for the appropriate telephone number.
When the XMU+ answers the line, it responds Enter Access Code.
2.
Enter the appropriate Remote Access code, followed by #. See Physical
Specifications on page 21 for the appropriate access code.
The access code entered determines the functions and options that the user is allowed access to. See
Understanding XMU+ Remote Telephone Access on page
The XMU+ responds Enter Command.
3.
Enter the command number (see
Remote Telephone Access Commands on page
89), and follow the XMU+ responses until the desired command has been
completed.
Note: If an invalid command or message number is selected, the XMU+ responds with the following message:
Error - Invalid Command or Error - No or Invalid Message .
To disconnect from the XMU+
1.
Complete the command.
2.
Press 0, followed by #.
The XMU+ responds Done, and disconnects the line.
Note: If a remote command is not received within 30 seconds, the XMU+ automatically disconnects from the line.
XMU+ Installation and Maintenance Guide rev.07
91
Understanding XMU+ Remote Telephone Access
5.
6.
3.
4.
To record a message remotely
1.
2.
Determine the number of the message you want to record.
Remotely access the XMU+. See Working with Remote Telephone Access
Messages on page 90 for more information.
When the XMU+ responds Enter Command, press 7.
Press the message number (nnn) you want to record, followed by #.
When the XMU+ responds with a short beep, record the message.
Press # to stop recording.
The XMU+ responds with Message ‘nnn’ recorded.
3.
4.
To play a message remotely
1.
2.
Determine the number of the message you want to play.
Remotely access the XMU+.
See Working with Remote Telephone Access Messages on page 90 for more
information.
When the XMU+ responds Enter Command, press 8.
Press the message number (nnn) you want to play, followed by #.
XMU+ plays the message.
5.
Press # to stop playing the message.
TIP...
To cancel the delete command, hang up before you reach
Step 3.
3.
4.
5.
To delete a message remotely
1.
2.
Determine the number of the message you want to delete.
Remotely access the XMU+.
See Working with Remote Telephone Access Messages on page 90 for more
information.
When the XMU+ responds Enter Command, press 39.
Press the message number (nnn) you want to delete, followed by #.
The XMU+ will respond with a verbal confirmation ‘done’.
92 Chapter 7
Understanding XMU+ Navigation
To change default language of operation (optional)
When the XMU+ is accessed remotely, the first response it gives is always in English
(Enter Access Code). The language it responds with from that point is also English, unless the language of operation is changed to French, Spanish, German, or
Portuguese.
2.
3.
With single or multi-partitioned XMU+ units, each partition can be programmed to respond with a different language.
1.
Remotely access the XMU+. See Working with Remote Telephone Access
Messages on page 90 for more information.
When the XMU+ responds Enter Command, press 4.
Press the number for the language you want to use, followed by #:
Press 1 # for English (default).
Press 2 # for French.
Press 3 # for Spanish.
Press 4 # for German.
Press 5 # for Portuguese.
The XMU+ will now use the selected language as its default language of
operation for Remote Access.
Testing XMU
+
Installation
The final step in XMU+ installation is to ensure that the XMU+ is properly connected to the PBX.
There are two tests that must be completed to confirm that the XMU+ system has been installed correctly:
Test system power and basic processor card operation.
See Testing Basic XMU+ System Health on page 96.
Test the telephone lines connected to the XMU+ to ensure that they are
connected and active. See Testing XMU+ Line Connections on page 100.
In this chapter...
About XMU+ Testing on page 95.
Testing Basic XMU+ System Health on page 96.
Testing XMU+ Line Connections on page 100.
8
94 Chapter 8
Testing XMU+ Installation
XMU+ Installation and Maintenance Guide rev.07
95
About XMU+ Testing
About XMU
+
Testing
Complete the following activities to prepare for and test XMU+ setup:
T e s t X M U + S e t u p
P r e p a r e X M U + f o r T e s t i n g
S e t u p a n d T e s t
C o m m u n ic a t io n
T e s t X M U +
L in e s
1.
2.
3.
Test basic XMU+ system health. See
Testing Basic XMU+ System Health on page
Test XMU+ communication to ensure that the communication ports are working correctly.
Test XMU+ telephone lines to ensure that the XMU+ is properly connected to the PBX. See
Testing XMU+ Line Connections on page 100 for more
information.
96 Chapter 8
Testing XMU+ Installation
Testing Basic XMU
+
System Health
Complete the following basic XMU+ activities to test system power and basic processor operations.
1.
2.
Check system power. See
Set the time and date. See
To check system power on page 96.
To set time and date (from the Front Panel) on
Note: Although all tasks in this section can be completed using both the Front Panel and
XMUCOM+, only the steps using the Front Panel are shown. See
XMU+ Front Panel on page 81 for more information.
To check system power
1.
Plug the XMU+ into an approved power source (AC or DC, depending on the
XMU+ system being tested).
2.
Verify that the LCD is active (illuminates with black text on a green background).
3.
If this XMU+ is a large chassis, verify that the LED indicators on the Power
Supply card(s) are illuminated green.
To set time and date (from the Front Panel)
1.
2.
Press Enter to access the Main Menu.
Press the Right Arrow until you reach System on the Main Menu and press
Enter.
3.
Press the Right Arrow button until you reach Time/Date on the System menu and press Enter to select Time/Date.
4.
Press Enter to select Time on the Time/Date menu, then press Enter again to make the “hour” section of the display flash.
5.
Change the hour using the Right Arrow and Left Arrow buttons, and then press Enter. The next section of the display will begin to flash.
6.
Repeat Step 5 to change the minutes and seconds, and then press Exit to return to the Time/Date menu.
7.
Press the Right Arrow button to reach Date on the Time/Date menu, and press
Enter. Press Enter again to make the “day” section of the display flash.
XMU+ Installation and Maintenance Guide rev.07
97
Testing Basic XMU+ System Health
8.
Change the day using the Right Arrow and Left Arrow buttons, and then press
Enter. The next section of the display will begin to flash.
9.
Repeat Step 8 to change the month and year, and then press Exit to return to the
Time/Date menu.
10.
Press Exit until the menu returns to the main display.
98 Chapter 8
Testing XMU+ Installation
TIP...
To change only a select group of three digits:
Press Enter until the appropriate group of three digits is flashing.
Change the digits.
Press Exit twice to return to the
Ethernet menu.
Assigning and Testing IP addresses
1.
Press Enter on the XMU+ Front Panel to access the Main
Menu.
2.
Press the Right Arrow to reach System on the Main
Menu, and press Enter.
3.
4.
5.
Press Enter to access Communications.
Press Enter to select Ethernet.
Press Enter to select IP Address.
The XMU+ displays the default IP address.
6.
Press Enter to make the first three digits of the address flash.
7.
Change the first three digits of the address using the
Right Arrow (to increase the number) and Left Arrow
(to decrease the number), and then press Enter. The next three digits of the address will begin to flash.
8.
Repeat Step 7 until the appropriate IP address has been entered, and press Enter.
9.
Press Exit until the menu returns to the main display.
10.
If required, assign an IP Netmask and IP Gateway to the
XMU+ by:
Repeating Steps 1 to 4, above.
At Step 5, pressing the Right Arrow to reach IP
Netmask or IP Gateway, and then pressing Enter.
Continuing with Steps 6 to 9 to change the default IP
Netmask or IP Gateway.
Note: Normally, the default IP Netmask and IP Gateway are used for communication with XMU+. If these numbers are changed in the procedure
above, ensure that the new numbers are recorded in Communication Specifications on page 25 of
.
XMU+ Installation and Maintenance Guide rev.07
99
Testing Basic XMU+ System Health
To ping the IP address
Ethernet communication with XMU+ can be verified by conducting a communication test from a PC with a LAN or direct Ethernet connection to the XMU+.
1.
2.
Choose Start > Run to display the Run window.
Type ‘command’ in the Open field and click OK to display a DOS window.
3.
At the command line prompt, enter ‘ping IP Address of the XMU+’.
‘IP Address of the XMU+’ is the IP address assigned to the XMU+ in Assigning and
Testing IP addresses on page 98.
A successful communication will show a result similar to the following:
4.
If the communication is unsuccessful, troubleshoot.
100 Chapter 8
Testing XMU+ Installation
Testing XMU
+
Line Connections
Each telephone line connected to the XMU+ should be tested to ensure proper connection to the PBX. To ensure that the lines are actually ringing, and that the
XMU+ is answering correctly, you must:
Ensure that a message has been recorded. See
To record a message on page 83
(via Front Panel) or
To record a message remotely on page 91(via Remote Access).
Assign the message to a line. See
Testing XMU+ Line Connections on page 100.
Set the XMU+ mode of operation. See
To set line card operating modes on page
Test the telephone line to ensure the message plays. See To test lines on page 103.
Note: Although all tasks in this section can be completed using Front Panel and
XMUCOM+, only the steps using the Front Panel are shown. See
XMU+ Front Panel on page 81 for more information.
To assign messages to a line (from the Front Panel)
In order to configure the XMU+ to play messages, each message must first be configured to play on the appropriate line. The number of lines on the XMU+ is determined by the number of line cards installed. See
Line Card Checklist on page 14
to determine the number of line cards installed.
4.
5.
1.
2.
When you assign a message to a line, it becomes that line’s starting node. By default, the XMU+ assigns message 1 to line 1’s starting node, message 2 to line 2’s starting node, and so on.
Press Enter to access the Main Menu.
Press the Right Arrow until you reach Card on the Main Menu, and press
Enter.
3.
Press the Right Arrow until you reach the appropriate line card number, and press Enter.
Press Enter to select Select Line.
Press the Right Arrow until you reach the line to which you want to assign a message, and press Enter. You can choose:
One of the 8 lines on the line card (individually). Press Enter again to accept.
All lines (1 to 8). When ALL is selected, a warning message appears. Press
Enter again to accept.
XMU+ Installation and Maintenance Guide rev.07 101
Testing XMU+ Line Connections
8.
9.
6.
7.
Press Right Arrow to select the Starting Node.
Press Enter until the starting message number (for example: Play 1) begins to flash.
Press the Right Arrow until the starting message you want to apply to this line is flashing, and press Enter.
Press Exit until the menu returns to the main display.
102 Chapter 8
Testing XMU+ Installation
To set line card operating modes
4.
5.
1.
2.
The mode of operation specified for the lines of each XMU+ line card controls the signaling to and from the PBX. Set the operating mode for each line card in your
XMU+ unit.
Press Enter to access the Main Menu.
Press the Right Arrow to reach Card on the Main Menu, and press Enter.
3.
Press the Right Arrow button until you reach the desired
card number on the menu, and press Enter.
Press Enter to select Select Line on the menu.
Press the Right or Left Arrow buttons until you reach the
ALL option on the menu, and press Enter. The display will now show Warning! All lines selected.
6.
Press Enter to acknowledge your selection of all XMU+ lines on this line card.
7.
Press the Right Arrow button until you reach the Mode option on the menu, and press Enter. Press Enter a second time to change the operating mode.
8.
Press the Right Arrow button until you reach the desired operating mode, and press Enter. Listed here in the order they are displayed on the XMU+, you can choose from the following operating modes:
R - Ring Start with loop detect (default for passive, interactive, and Hybrid Analog line cards).
RN - Ring Start with no loop detect.
RQ - Ring Quick with loop detect.
RD - Ring with DTMF disconnect. (Use A, B, C or D to disconnect.)
RB (RB+) - Ring with busy disconnect.
RT (RT+) - Ring with Dial Tone disconnect.
LS/PR SP NO - Level Start/Pulse Return single play, CP relay normally open.
LS/PR SP NC - Level Start/Pulse Return single play, CP relay normally closed.
LS/PR MP NO - Level Start/Pulse Return multiple play, CP relay normally open.
LS/PR MP NC - Level Start/Pulse Return multiple play, CP relay normally closed.
LS/LR SP NO - Level Start/Level Return single play, CP relay normally open.
XMU+ Installation and Maintenance Guide rev.07 103
Testing XMU+ Line Connections
LS/LR SP NC - Level Start/Level Return single play, CP relay normally closed.
PS/LR NO - Pulse Start/Level Return, CP relay normally open.
PS/LR NC - Pulse Start/Level Return, CP relay normally closed.
PS/PR NO - Pulse Start/Pulse Return, CP relay normally open.
PS/PR NC - Pulse Start/Pulse Return, CP relay normally closed.
CP - Continuous Play, no relay toggle.
CP NO - Continuous Play, CP relay normally open. (Default for low impedance line cards.)
CP NC - Continuous Play, CP relay normally closed.
SCP NO - Synchronized Continuous Play, CP relay normally open.
SCP NC - Synchronized Continuous Play, CP relay normally closed.
Off-line - Line will not operate.
9.
If required (for operating modes R, RN, RB, RB+, RT, RT+ and RD), press the
Right Arrow button until you reach the desired ring limit, and press Enter. The ring limit is the number of cycles (rings) that the XMU+ will wait before answering the line (default is 1).
10.
Press Exit until the menu returns to the main display.
11.
If operating mode R is selected, perform a line check.
See To perform a line check on page 124 for more
information.
12.
Record the line card operation modes in the Delivery
Checklist. See
The XMU+ Delivery Checklist on page 21.
To test lines
1.
2.
Collect all applicable telephone (line) numbers.
Record all telephone numbers in the Delivery Checklist.
See The XMU+ Delivery Checklist on page 21.
3.
Ring the appropriate line by dialing the telephone number.
If the XMU+:
Answers and the message plays, the line cards are properly cabled.
Does not answer or the message does not play, troubleshoot. See If XMU+
Is Not Answering on page 121 for more information.
4.
Repeat step 3 until all the lines have been tested.
104 Chapter 8
Testing XMU+ Installation
XMU
+
Hardware Upgrades
From time-to-time, you may need to upgrade some of the hardware features of your XMU+, such as memory or line cards. This chapter outlines some of the more common tasks that you may need to perform.
In this chapter...
Standard XMU+ Tasks on page 107.
Upgrading Line Cards on page 109.
Replacing Control Cards on page 112.
Replacing the XMU+ Large Chassis Power Supply on page 114.
Upgrading Control Card Memory on page 116.
9
106 Chapter 9
XMU+ Hardware Upgrades
ESD
Electrostatic
Discharge
XMU+ Installation and Maintenance Guide rev.07 107
Standard XMU+ Tasks
Standard XMU
+
Tasks
The following standard procedures may be required on their own, or as a part of more complete upgrade procedures. They should be reviewed thoroughly.
XMU+ maintenance and upgrades should only be completed by a qualified telecommunications / electronics technician. Standard static discharge precautions must be followed when handling any internal components. ESD precautions should also be observed.
Interalia cannot be held responsible for damage to parts or equipment caused by improper handling or installation.
To take the XMU
+
offline
6.
7.
4.
5.
Take the XMU+ offline before performing maintenance tasks to ensure that callers are not cut-off abruptly.
1.
2.
Press Enter to access the Main Menu.
Press the Right Arrow to reach Card on the Main
Menu, and press Enter.
3.
Press the Right Arrow button until you reach the
desired card number on the menu, and press Enter.
The display will now show Card # 1 Select Line.
Press Enter to select Select Line.
Press the Right Arrow button until you reach the ALL option on the menu, and press Enter. The display will now show Warning! All lines selected.
Press Enter to acknowledge the warning message.
Press the Right Arrow button until you reach the
Mode option on the menu, and press Enter twice.
8.
Press the Right Arrow button until you reach the
Offline mode, and press Enter.
9.
Press Exit until the menu returns to the main display.
108 Chapter 9
XMU+ Hardware Upgrades
To back up the current configuration
To reduce the amount of time required to restore the XMU+ in the event of a system failure, you should back up the configuration and messages contained within the
XMU+ to a PC using XMUCOM+ before you begin any maintenance or upgrade procedure. See the XMU+ QuickStart Guide for more information.
If you cannot back up the XMU+ with XMUCOM+ software, make sure that you:
1.
Obtain an up-to-date listing and description of the configuration.
2.
3.
Obtain the current text of all messages (so that they can be re-recorded later).
Understand Front Panel navigation and programming. See
Hierarchy - Single Partition Mode on page 77.
To power down the XMU
+
1.
Back up the configuration and messages contained within the XMU+.
See To back up the current configuration on page 108.
2.
Unplug the XMU+ from its power supply and all telephone lines.
To bring the XMU
+
online
1.
2.
Depending on the task performed while the XMU+ is offline, the XMU+ may maintain its time and date, messages, and configurations - even if the system is down for days.
However, after certain tasks are performed you may need to reload messages and configurations, and to reset the time and date.
Connect the XMU+ to the power supply and telephone lines.
If required, load all messages and configurations using:
XMUCOM+ software. See the XMU+ QuickStart Guide for more information.
Front Panel. See
on page 82 and Testing XMU+ Line
3.
Set time and date. See
To set time and date (from the Front Panel) on page 96.
XMU+ Installation and Maintenance Guide rev.07 109
Upgrading Line Cards
Upgrading Line Cards
Your XMU+ can be upgraded to provide new functionality. While standard static discharge precautions should be observed, it is not necessary to power down the XMU+ before working with line cards. See
Standard XMU+ Tasks on page 107 for details.
In order to make the line card replacement fast and easy, you should have a medium flat-blade screwdriver and a small Philips screwdriver on hand.
To remove a line card
3.
4.
1.
2.
5.
Take the XMU+ offline. See To take the XMU+ offline on page 107.
Locate the line card that you want to remove.
Remove the cabling from the back of the line card.
Loosen the two thumbscrews on either end of the line card’s faceplate.
Pull the line card straight out.
Caution...
Forcing the line card into place could cause the pins on the connector to bend.
To install a new line card
This procedure for installing (or reinstalling) XMU+ line cards applies only to the following types of line cards:
Hybrid Analog.
Low Impedance.
MWR.
Passive (found on older XMU units).
Interactive (found on older XMU units).
6.
7.
8.
4.
5.
See page 110 for instructions for installing (or reinstalling) T1 and MOH line cards.
1.
Remove any line cards that conflict with the new line card to be installed.
See Understanding Line Card Population Rules on page 30 and
To remove a line card on page 109 for more information.
2.
Locate the slot where the new line card will reside and ensure the faceplate does not have a warning sticker, as shown in
Understanding Line Card Population Rules on page 30.
3.
Remove the blank faceplate or existing line card. See
Line up the line card’s circuit board on the plastic rails in the chassis.
Slide the line card into place.
When seating the line card, there should be slight resistance.
Tighten the thumbscrews on either end of the line card’s faceplate.
Attach the appropriate cable. See
Confirm that the XMU+ recognizes the new line card. See
110 Chapter 9
XMU+ Hardware Upgrades
Caution...
Forcing the T1 line card into place could bend the pins on the connector.
Caution...
Forcing the MOH line card into place could bend the pins on the connector.
4.
5.
6.
7.
To install a new T1 line card
1.
Determine whether the T1 line card will reside in slot 1 or slot 5, and locate that slot on the back of the large XMU+ unit.
The small chassis can have a single T1 card.
2.
3.
8.
If required, remove any line cards that conflict with the new T1 line card to be
installed. See Understanding Line Card Population Rules on page 30 and
To remove a line card on page 109 for more information.
Ensure that the appropriate settings have been applied to the T1 line card. See
Chapter 3 of the XMU+ Installation Handbook for more information.
Line up the T1 line card’s circuit board on the plastic rails in the chassis.
Slide the T1 line card into place.
When seating the card, there should be slight resistance.
Tighten the thumbscrews on either end of the T1 line card’s faceplate.
Connect the RJ-45 connector to the port on the T1 line card. See
To cable T1 line cards on page 54 for more information.
Confirm that the XMU+ recognizes the new line card. See To verify line card operation on page 111.
6.
7.
4.
5.
To install a new MOH card
1.
Determine where the MOH line card will reside, and locate that slot on the back of the XMU+ unit.
2.
If required, remove any line cards that conflict with the new MOH line card to be installed. See
Understanding Line Card Population Rules on page 30 and
To remove a line card on page 109 for more information.
3.
Ensure that the appropriate settings have been applied to the MOH line card.
See Applying MOH Line Card Settings on page 31 for more information.
Line up the MOH line card’s circuit board on the plastic rails in the chassis.
Slide the MOH line card into place.
When seating the card, there should be slight resistance.
Tighten the thumbscrews on either end of the line card’s faceplate.
Connect the RCA/Phono connectors to the appropriate port on the MOH line card. See
To cable MOH line cards on page 55 for more information.
8.
Confirm that the XMU+ recognizes the new line card. See To verify line card operation on page 111.
XMU+ Installation and Maintenance Guide rev.07 111
Upgrading Line Cards
To verify line card operation
Confirm that the XMU+ recognizes the newly installed line card.
1.
If required, bring the XMU+ back online. See page 108.
2.
Confirm that all required programming is in the XMU+ for the line card to function.
If the programming is not available, download the messages and configurations you backed up in
To back up the current configuration on page 108. See the
XMU+ QuickStart Guide for more information.
3.
Test the XMU+ lines. See
112 Chapter 9
XMU+ Hardware Upgrades
Replacing Control Cards
Removal of the Control card may be required for some XMU+ upgrades. As well, older
XMU units can be upgraded to obtain all XMU+ functionality (excluding the redundant power supply option) if a new Control card is installed. Control Cards should always be removed and/or installed by a trained technician.
To remove the Control card
1.
2.
Back up configuration and messages.
Take the XMU+ offline and power down. See
To take the XMU+ offline on page
To power down the XMU+ on page 108.
3.
Loosen the two thumbscrews on either end of the Control card’s faceplate.
See Product Overview on page 4 for a detailed diagram of the Control card.
4.
Pull the Control card straight out.
Caution...
Forcing the Control card into place could bend the pins on the connector.
5.
6.
2.
3.
4.
To install a new XMU
+
Control card
1.
Take the XMU+ offline and power down. See
To take the XMU+ offline on page
To power down the XMU+ on page 108.
Remove the old Control card. See
To remove the Control card on page 112.
Line up the new Control card’s circuit board on the plastic rails in the chassis.
Slide the new Control card into place.
It may be necessary to align the handset and tape input in the front of the unit while seating the card. When seating the card, there should be slight resistance.
Tighten the thumbscrews.
Bring the XMU+ back online. See
To bring the XMU+ online on page 108.
Once the XMU+ is powered up, it will automatically run a test of the memory and display the available recording time.
7.
Verify that the XMU+ displays the proper amount of recording time, as shown in the chart on the next page. The amount of memory available is determined by the memory modules installed on the Control card.
Memory Module Part Number...
Number of Minutes...
48995
48996
48997
8
16
32
XMU+ Installation and Maintenance Guide rev.07 113
Replacing Control Cards
Memory Module Part Number...
Number of Minutes...
48998
48986
48980
60
120
360
Note: All modules can co-exist on a Control card.
114 Chapter 9
XMU+ Hardware Upgrades
Caution...
Power supply may contain lethal voltage.
Replacing the XMU+ Large Chassis Power Supply
Removal of the Power Supply card from the XMU+ (large chassis only) may be required:
For some XMU+ repairs.
To troubleshoot power supply failures.
To change the power source (from AC to DC, or DC to AC).
To add a secondary power supply (AC or DC).
Large chassis power supply cards should always be removed and/or installed by a trained technician. Small chassis Power Supply cards are not field upgradable, and must be returned to the factory for replacement.
Note: Since the AC power cord is the disconnect for the XMU+, ensure that the AC receptacle is near the unit. See
XMU+ Approvals on page 143 for more information.
Bitte beachten Sie die wichtien Sicherheits informationen auf Seite 135, XMU+
Technical Specifications and Approvals
.
To remove a single Power Supply card
1.
Take the XMU+ offline and power down. See
To take the XMU+ offline on page
To power down the XMU+ on page 108.
2.
Loosen the two thumbscrews on either end of the Power Supply card’s faceplate.
See “Connecting the XMU+ to its Power Supply” in Chapter 2 of the XMU+
Installation Handbook for a detailed diagram of the Power Supply card.
3.
Pull the Power Supply card straight out.
Caution...
Forcing the Power
Supply card into place could bend the pins on the connector.
5.
6.
To install a new single Power Supply card
1.
Take the XMU+ offline and power down.
See To take the XMU+ offline on page 107 and
To power down the XMU+ on page 108.
2.
Remove the old Power Supply card.
See To remove a single Power Supply card on page 114.
3.
Line up the circuit board of the new Power Supply card on the plastic rails in the chassis.
4.
Slide the new Power Supply card into place.
When seating the card, there should be slight resistance.
Tighten the thumbscrews.
Bring the XMU+ back online. See
To bring the XMU+ online on page 108.
If the power supply card is properly installed and working, the LED indicator will be green.
XMU+ Installation and Maintenance Guide rev.07 115
Replacing the XMU+ Large Chassis Power Supply
To remove a secondary Power Supply card
One of the benefits of having dual power supplies is that there is no need to take the
XMU+ offline when one of the supplies needs to be removed.
1.
2.
Disconnect the power supply to be removed.
Loosen the two thumbscrews on either end of the Power Supply card’s faceplate.
See “Connecting the XMU+ to its Power Supply” in Chapter 2 of the XMU+
Installation Handbook for a detailed diagram of the Power Supply card.
3.
Pull the Power Supply card straight out.
Caution...
Forcing the Power
Supply card into place could bend the pins on the connector.
To install a secondary Power Supply card
4.
5.
One of the benefits of having dual power supplies is that there is no need to take the
XMU+ offline when a second supply is being added.
1.
2.
Line up the circuit board of the new Power Supply card on the plastic rails in the chassis.
3.
Slide the new Power Supply card into place.
When seating the card, there should be slight resistance.
Tighten the thumbscrews.
Connect the secondary Power Supply card to its power source.
If the Power Supply card is properly installed and working, the LED indicator will be green when the XMU+ is powered up.
116 Chapter 9
XMU+ Hardware Upgrades
Upgrading Control Card Memory
A XMU+ memory module can be added if more memory is required (up to a maximum of 6 hours). Memory may also need to be replaced due to:
Additional memory requirements for storing messages (up to a maximum of 6 hours).
A defective memory module.
The Control card location reserved for a memory module is labelled as Memory
Module 1.
Note: Due to the required factory startup after each memory upgrade or replacement, it is important to back up configurations and messages before working with XMU+ memory modules.
To replace an XMU
+
memory module
A memory module may need to be replaced due to:
Additional memory requirements (up to a maximum of 6 hours).
A defective memory module.
1.
Back up the configuration and messages contained within the XMU+.
See To back up the current configuration on page 108.
2.
Take the XMU+ offline and power down. See
To take the XMU+ offline on page
To power down the XMU+ on page 108.
3.
Remove the Control card. See
To remove the Control card on page 112.
The XMU+ will have one, two, or three memory modules installed in the sockets near the top edge of the Control card.
4.
Gently pull up on the memory module to be removed. A slight rocking motion may be needed to disengage it.
5.
Align the new module for mounting.
Several measures exist to prevent improper installation, including:
White alignment arrows on both the Control card and memory module should point in the same direction.
The large central hole in the memory module should engage with the plastic retainer on the Control card.
XMU+ Installation and Maintenance Guide rev.07 117
Upgrading Control Card Memory
6.
Gently press the memory module down so that the connectors mate and the plastic retainer snaps through the hole on the Control card. plastic retainer alignment arrows connectors
7.
8.
Replace the Control card. See
To install a new XMU+ Control card on page 112.
Bring the XMU+ back online. See
To bring the XMU+ online on page 108.
9.
Perform Factory Reset 1 to reset the XMU+. See
To reset unit to default factory settings (including flash memory) on page 132.
10.
Restore the configuration and messages to the XMU+. See the XMU+
QuickStart Guide for more information.
To add an XMU
+
memory module
1.
Back up the configuration and messages contained within the XMU+.
See To back up the current configuration on page 108.
Take the XMU+ offline and power down. See
To take the XMU+ offline on page
To power down the XMU+ on page 108.
2.
3.
Remove the Control card. See
To remove the Control card on page 112.
The XMU+ memory module is installed in a socket near the top edge of the
Control card.
Align the new module for mounting.
Several measures exist to prevent improper installation, including:
White alignment arrows on both the Control card and memory module should point in the same direction.
The large central hole in the memory module should engage with the plastic retainer on the Control card.
118 Chapter 9
XMU+ Hardware Upgrades
4.
Gently press the memory module down so that the connectors mate and the plastic retainer snaps through the hole on the Control card.
plastic retainer alignment arrows
7.
8.
5.
6.
connectors
Replace the Control card. See
To install a new XMU+ Control card on page 112.
Bring the XMU+ back online. See
To bring the XMU+ online on page 108.
Once the XMU+ is powered up, it will automatically run a memory test and display the available recording time.
Perform Factory Reset 1 to reset the XMU+. See
To reset unit to default factory settings (including flash memory) on page 132.
Restore the configuration and messages to the XMU+. See the XMU+
QuickStart Guide for more information.
Troubleshooting XMU
+
Installation
Follow the troubleshooting steps in this chapter to resolve any difficulties that arise during your XMU+ installation. If the XMU+ is still not functioning properly when you complete these steps, contact Interalia.
In this chapter...
If XMU+ Is Not Answering on page 121.
If Alarms Sound to Warn of XMU+ System Failures on page 126.
If XMU+ Hardware Failures Occur on page 127.
10
120 Chapter 10
Troubleshooting XMU+ Installation
XMU+ Installation and Maintenance Guide rev.07 121
If XMU+ Is Not Answering
If XMU
+
Is Not Answering
If the XMU+ does not answer a call, complete the troubleshooting tasks in the order shown until the problem is resolved.
If XMU+ Is Not Answering...
Verify that a message is recorded.
Ensure that a message is assigned to the line.
Check line card operating modes.
Check line card status.
Perform a line check.
Perform an integrity check.
Verify time and date.
Verify PBX/ line card timing.
122 Chapter 10
Troubleshooting XMU+ Installation
2.
3.
To verify that a message is recorded
1.
Identify the message number that should have played when the XMU+ was called.
Message information is collected during configuration design and implementation. See the XMU+ QuickStart Guide for more information about messages.
Play the message. See
If the message plays, proceed to the next troubleshooting task -
To ensure the message is assigned to a line .
4.
If the message does not play, it has not been recorded.
Record a new message. See
To record a message on page 83.
Assign the message to a line. See Testing XMU+ Line Connections on page 100.
To ensure the message is assigned to a line
Every message must be configured to play on the appropriate line. When you assign a message to a line, it becomes its starting node. By default, the XMU+ assigns message 1 to line 1’s starting node, message 2 to line 2’s starting node, and so on.
1.
Identify the message number and line card that the message should be assigned to.
Message information is collected during configuration design and implementation. See the XMU+ QuickStart
Guide for more information about messages.
2.
Follow Steps 1 to 6 of
Testing XMU+ Line Connections on
3.
Ensure that the appropriate starting message is displayed
(Play 1, for example, as shown to the right).
4.
If the correct message number is displayed, proceed to the next troubleshooting task -
5.
If the correct message number is not displayed, assign the message to the line by completing Steps 7 to 9 of
Testing XMU+ Line Connections on page 100.
XMU+ Installation and Maintenance Guide rev.07 123
If XMU+ Is Not Answering
To check operating modes
5.
6.
The operating modes specified for each XMU+ line card control the signaling to and from the
PBX. See
About XMU+ Operating Modes for more information.
1.
Identify the correct operating mode for each line card.
See
The XMU+ Delivery Checklist on page 21.
2.
Follow Steps 1 to 6 of
To set line card operating modes on page
3.
Ensure that the appropriate operating mode is displayed for the first line card (R, for example, as shown to the right).
4.
If the correct operating mode is not displayed, set the operating mode by completing Steps 7 to 10 of
To set line card operating modes on page 102.
Repeat Steps 2 and 3 for every line card.
If the correct operating mode is displayed on all line cards,
proceed to the next troubleshooting task - To check line status .
To check line status
The Status Check feature checks the lines to ensure that a card is installed, and to show the status of each card (for example, idle, ringing, etc.).
1.
2.
Press Enter to access the Main Menu.
Press the Right Arrow to reach Card on the Main Menu, and press Enter.
3.
Press the Right Arrow to select the appropriate Card #, and press Enter.
4.
Press the Right Arrow to reach Status, and press Enter.
The XMU+ will display one of the following status indicators:
-------- - no card is installed. See To install a new line card on page 109 to install the card.
EEEEEEEE - a configuration problem exists. See To perform an integrity check on page 125.
YYYYYYYY - card is ready. Proceed to Step 5.
NNNNNNNN - card is not ready (offline). Proceed to
Step 6.
5.
If a T1 line card is installed, press Enter again. The XMU+ displays a T1 interface status indicator. Proceed to the next troubleshooting task -
To perform a line check on page 124.
6.
If the card fails the status check, complete the following troubleshooting tasks.
Ensure a starting message is assigned. See
Ensure operating mode is set correctly. See
To set line card operating modes on page 102.
124 Chapter 10
Troubleshooting XMU+ Installation
The following is a list of the line status indicators:
‘-’ - line not installed
‘N’ - offline
‘E’ - configuration error exists
‘Y’ - line idle
‘M’ - call transfer queue MOH message
‘C’ - line connected
‘R’ - ringing on line
‘H’ - hold messages being played
‘b’ or ‘B’ - call transfer detecting a busy cadence
‘A’ call transfer detecting line has been answered
‘r’ or ‘R’ - call transfer detecting ring-back cadence
‘0 -9’ , ‘#’ , ‘*’ - DTMF digits generated
‘ , ' - 1/2 second pause
‘ ! ' - hookflash
‘d’ or ‘D’ - call progress monitoring
To perform a line check
1.
2.
The Line Check feature checks the lines to ensure a telephone line is connected to the channel. It is only used for lines that are configured to Ring Start mode. See
To check operating modes on page 123 to confirm that the line is in Ring Start mode.
Press Enter to access the Main Menu.
Press the Right Arrow to reach System on the Main
Menu, and press Enter.
3.
Press the Right Arrow to reach Diagnostics, and press
Enter.
4.
Press the Right Arrow to reach Line Check, and press
Enter.
5.
Press the Right Arrow to reach the desired card and
line to be tested, and press Enter.
Each line will display Pass or Fail.
6.
Repeat Step 5 until all the desired cards and lines are checked:
If all line cards pass the line check, proceed to the next troubleshooting task -
.
If any line cards fail the line check, ensure a starting node is assigned. See
Testing XMU+ Line Connections on page 100.
XMU+ Installation and Maintenance Guide rev.07 125
If XMU+ Is Not Answering
To perform an integrity check
The Integrity Check feature checks the configuration to ensure that all messages used in a configuration are recorded.
1.
2.
Press Enter to access the Main Menu.
Press the Right Arrow to reach System on the Main
Menu, and press Enter.
3.
Press the Right Arrow to reach Diagnostics, and press
Enter.
4.
Press the Right Arrow to reach Integrity Check, and press Enter. The XMU+ runs the integrity check.
5.
If no error message is displayed, proceed to the next
troubleshooting task To verify time and date .
6.
If an error message is displayed:
Record it on paper, and press Enter to view the next error. Repeat this step until you have reviewed and recorded all errors.
Correct all errors appropriately.
To verify time and date
1.
Review the time and date on the main display.
2.
If the time and date are correct, proceed to the next troubleshooting task -
To verify timing between PBX and line cards .
3.
If the time and date are incorrect, reset them. See To set time and date (from the
4.
5.
6.
To verify timing between PBX and line cards
1.
2.
Ensure the PBX is configured correctly.
Identify the operating mode assigned to each line card. See
3.
Review the appropriate timing diagrams. See
About XMU+ Operating Modes on page 68.
Ensure the PBX timing matches the timing on the diagrams.
If the timing is correct, proceed to the next troubleshooting task.
If the timing is incorrect, change the XMU+ operating mode. See
To set line card operating modes on page 102.
126 Chapter 10
Troubleshooting XMU+ Installation
If Alarms Sound to Warn of XMU
+
System Failures
The XMU+ can be connected through the alarm contact pinout on the rear of the
Control card to a light or a buzzer. If a power supply failure or microprocessor system failure occurs, a contact closure is generated on the alarm connector, which then triggers the external device (light or buzzer). See
Connecting Alarms (optional) on page 52 for more information).
If this alarm sounds (or flashes), complete the troubleshooting tasks listed in
To respond to alarms from XMU+
to resolve the problem.
To respond to alarms from XMU
+
1.
Ensure that the alarm connector is properly wired. See To wire the alarm connector on page 53.
2.
If the alarm connector is properly wired, proceed to the first troubleshooting task in
If XMU+ Hardware Failures Occur on page 127 (
To check for XMU+ power supply failures - Small Chassis ).
XMU+ Installation and Maintenance Guide rev.07 127
If XMU+ Hardware Failures Occur
If XMU
+
Hardware Failures Occur
If the XMU+ does not come online, complete the following troubleshooting tasks in the order shown until the problem is resolved.
If XMU+ Hardware Failures Occur...
Check for power supply failures.
Verify that power circuits are functional.
Verify line card operation.
Verify T1/E1 line card operation.
Perform an audio test.
Perform a reset.
Perform a quick reset.
Select a previous firmware version.
Reset XMU+ to factory defaults.
128 Chapter 10
Troubleshooting XMU+ Installation
To check for XMU
+
power supply failures - Small Chassis
1.
Ensure that the Front Panel display is active (lit-up).
If the Front Panel display is active, proceed to the next troubleshooting task
-
To verify AC/DC power circuits are functional .
If the Front Panel display is not active, remove the Power Supply card, and
reinstall it to ensure proper seating. See To remove a single Power Supply card on page 114.
2.
If the LED indicator is still not green, return the XMU+ to the factory to have the Power Supply card replaced with a new one.
2.
3.
To check for XMU
+
power supply failures - Large Chassis
1.
Ensure that the Front Panel display is active (lit-up).
If the Front Panel display is active, proceed to the next troubleshooting task
-
To verify AC/DC power circuits are functional .
If the Front Panel display is not active, proceed to Step 2.
Ensure that the Power Supply card LED indicator is green.
If the LED indicator is green, proceed to the next troubleshooting task -
To verify AC/DC power circuits are functional
.
4.
If the LED indicator is not green, remove the Power Supply card, and reinstall it to ensure proper seating. See
Replacing the XMU+ Large Chassis Power Supply on page 114.
5.
If the LED indicator is still not green, replace the Power Supply card with a new one.
See Replacing the XMU+ Large Chassis Power Supply on page 114.
To verify AC/DC power circuits are functional
1.
2.
Ensure that the appropriate power supply (AC or DC) is in operation.
If the appropriate power supply is not in operation, contact the appropriate repair/maintenance department at the power company.
3.
If the appropriate power supply is in operation, ensure that the unit is properly plugged into its power supply. See “Connecting the XMU+ to its Power Supply” in Chapter 2 of the XMU+ Installation Handbook.
4.
If the unit is properly plugged into its power supply, proceed to the next troubleshooting task -
To verify line card operation and wiring
.
To verify line card operation and wiring
Complete this troubleshooting step for each line card, excluding T1 line cards.
XMU+ Installation and Maintenance Guide rev.07 129
If XMU+ Hardware Failures Occur
1.
2.
3.
Check the status of each line card from the Front Panel. See
To check line status on page 123.
If the line cards all appear ready after the status check has been completed,
ensure that each line card is properly cabled to the PBX. See Cabling XMU+
If all line cards are properly cabled to the PBX, proceed to the next troubleshooting task -
To perform an audio test on page 130.
To verify T1 line card operation and cabling
1.
Ensure that each T1 line card is properly cabled to the PBX. See Cabling XMU+
2.
If all line cards are properly cabled, ensure that the LED indicator on each T1 line card is flashing green.
3.
If all LED indicators are flashing green, check the status of each T1 line card
from the Front Panel. See To check line status on page 123.
4.
If the T1 line cards all appear ready after the status check has been completed, perform an audio test. See
To perform an audio test on page 130.
5.
If the T1 line cards are all operating after the status check has been completed, ensure the T1 line cards are set correctly. See Chapter 3 of the XMU+
Installation Handbook.
6.
If all line cards are set correctly, proceed to the next troubleshooting task -
.
130 Chapter 10
Troubleshooting XMU+ Installation
To perform an audio test
3.
4.
5.
Perform an audio test to check for line malfunctions.
1.
Press Enter to access the Main Menu.
2.
Press the Right Arrow to reach System on the Main Menu, and press Enter.
Press the Right Arrow to reach Diagnostics, and press Enter.
Press the Right Arrow to reach Audio Test, and press Enter.
Press the Right Arrow to reach the desired card and line to be
tested, and press Enter. The XMU+ goes through each line individually.
If a 1KHz tone sounds, the line is operating.
If no tone sounds, there is a line malfunction. Ensure that each line card is properly cabled to the PBX. See
6.
Press Exit until the menu returns to the main display.
TIP...
To cancel the reset command and return to the previous menu, press Exit when XMU+ asks Are you sure?.
To perform a reset
1.
2.
Performing a reset on the XMU+ when it has lost power or has frozen will NOT erase messages or configurations. The XMU+ shuts down slowly, as it waits until all lines have disconnected before shutting down and restarting. This could take minutes or hours.
Press Enter to access the Main Menu.
Press the Right Arrow to reach System on the Main Menu, and press Enter.
3.
Press the Right Arrow to reach System Reset, and press
Enter.
4.
Press Enter to select Reset on the menu.
XMU+ displays a message asking if you are sure that you want to perform this reset.
5.
Press Enter to perform the reset.
The XMU+ backs up statistics, waits until all lines have disconnected, and then restarts.
XMU+ Installation and Maintenance Guide rev.07 131
If XMU+ Hardware Failures Occur
TIP...
To cancel the quick reset command and return to the previous menu, press
Exit when XMU+ asks Are you sure?.
To perform a quick reset
1.
2.
Perform a quick reset of the XMU+ system when it must be reset immediately. Unlike a reset, a quick reset does not wait for all lines to disconnect before shutting down.
Quick resets will NOT erase messages or configurations.
Press Enter to access the Main Menu.
Press the Right Arrow to reach System on the Main
Menu, and press Enter.
3.
Press the Right Arrow to reach System Reset, and press Enter.
4.
Press the Right Arrow to reach Quick Reset, and press
Enter. XMU+ displays a message asking if you are sure that you want to perform this reset.
5.
Press Enter to perform the quick reset.
The XMU+ shuts down immediately, and then restarts.
APP Image
Application Image
To select a previous firmware (APP Image) version
If a firmware upgrade fails during download, of if a firmware upgrade is defective, you may need to return the XMU+ to a previous firmware version. This could affect recorded messages and configurations.
1.
Power down the XMU+.
See To power down the XMU+ on page 108.
2.
Connect the XMU+ to its power supply while holding down the Enter key.
XMU+ displays all previously installed firmware (APP) version numbers. A * is shown beside the current version number.
3.
Press the appropriate Arrow (Left or Right) to reach the desired firmware (APP) version.
4.
Press Enter. XMU+ resets the firmware to the selected version and displays a message asking if you want to perform a Factory Reset.
5.
If you select:
YES, the XMU+ will reset to its default factory settings. This will erase ALL messages and ALL configurations, so you will have to download
132 Chapter 10
Troubleshooting XMU+ Installation configurations and messages. See the XMU+ QuickStart Guide for more information.
NO, the XMU+ will return to the Time/Date display, leaving messages and configurations intact.
CAUTION...
If you select YES, this procedure will erase
ALL messages and delete ALL configurations.
To reset unit to default factory settings (including flash memory)
Resetting the XMU+ to its original factory default settings should be performed only as a last resort, when the XMU+ is behaving erratically and has not responded to any other troubleshooting procedures.
The manner in which you perform a factory reset depends on whether or not the
XMU+ front panel is still active. If the front panel is:
Still active, perform Factory Reset 1.
Completely unresponsive, perform Factory Reset 2.
In either case, this procedure will erase ALL messages and delete ALL configurations, and return the XMU+ to its original factory settings.
TIP...
To cancel the factory default command and return to the previous menu, press
Exit when XMU+ asks Are you sure?.
Factory Reset 1
1.
2.
Press Enter to access the Main Menu.
Press the Right Arrow to reach System on the Main
Menu, and press Enter.
3.
Press the Right Arrow to reach System Reset, and press Enter.
4.
Press the Right Arrow to reach Factory Default, and press Enter. XMU+ displays a message asking if you are sure that you want to perform this reset.
5.
Press Enter to perform the factory reset.
The XMU+ shuts down immediately, and then restarts.
XMU+ Installation and Maintenance Guide rev.07 133
If XMU+ Hardware Failures Occur
TIP...
If you do not select
YES or NO, the XMU+ will time-out after five seconds and display the Time/
Date.
Factory Reset 2
1.
Power down the XMU+. See To power down the XMU+ on page 108.
2.
Connect the XMU+ to its power supply while holding down the Enter key.
XMU+ displays all previously installed firmware (APP) version numbers. A * is shown beside the current version number.
3.
Press Enter to select the current firmware (APP) version number.
XMU+ displays a message asking if you want to perform a Factory Reset.
4.
Press the Right Arrow (YES) to reset the XMU+ to its default factory settings.
The XMU+ erases ALL messages and ALL configurations.
5.
Download configurations and messages.
See the XMU+ QuickStart Guide for more information.
134 Chapter 10
Troubleshooting XMU+ Installation
XMU
+
Technical
Specifications and Approvals
11
Technical Specifications are important attributes of XMU+ that have been detailed in this chapter for reference.
System level specifications are those such as dimensions, weight, overall frequency response, and core characteristics.
Card level specifications are those such as port impedances, output levels, and connector types.
The Approvals information in this chapter details the standards that XMU+ conforms with.
Safety approvals: XMU+ compliance with safety standards.
Telecom approvals: XMU+ compliance with telephone network standards.
Emissions: XMU+ compliance with radiated and conducted emission
(and immunity) standards.
Vorsicht:
Sicherheitshinweis: Der Netzstecker ist die An-/Ausschaltung für die XMU+. Vergewissern Sie sich deshalb, daß der
Nestzanschluß in der Nähe der Maschine und leicht erreichbar ist. Weitere Informationen finden Sie auf Seite 17, Installation
Handbook.
In this chapter...
Detailed XMU+ Technical Specifications on page 137.
136 Chapter 11
XMU+ Technical Specifications and Approvals
XMU+ Installation and Maintenance Guide rev.07 137
Detailed XMU+ Technical Specifications
Detailed XMU
+
Technical Specifications
The following tables describe the technical features of the XMU+. These XMU+ features are approximate, and are subject to change without notice.
System Specifications
Technical Feature...
Details...
Physical
Unit Dimensions:
Rack Space:
Shipping
Dimensions:
Unit Maximum
Weight:
Shipping Maximum
Weight:
Large chassis: 177 x 444 x 330 mm (7.0 x 17.5 x 13.0 inches)
Small chassis: 44 x 444 x 330 mm (1.75 x 17.5 x 13.0 inches)
Large chassis: 4 units
Small chassis: 1 unit
Large chassis: 260 x 500 x 500 mm (10.25 x 19.7 x 19.7 inches)
Small chassis: 107 x 540 x 455 mm (4.3 x 21.3 x 18.0 inches)
Large chassis: 9.4 Kg (20.7 pounds)
Small chassis: 3.1 Kg (6.9 pounds)
Large chassis: 12.9 Kg (28.4 pounds)
Small chassis: 6.2 Kg (13.6 pounds)
Power and Thermal
Power Consumption:
Heat Production:
Large Chassis: 220 Watts maximum
Small Chassis: 50 Watts maximum
Large Chassis: 220 Watts (750 BTU/hr) maximum
Small Chassis: 50 Watts (160 BTU/hr) maximum
Note: BTU/hr = Consumption in Watts x 3.415
Environmental
Temperature:
Dust:
0 - 40 degrees o C (32 - 104 o F) temperature range. Adequate cooling or heating must be provided to guarantee this range.
Units not for operation in conductive dust atmospheres (i.e. coal dust, metal dust, etc.).
Units not for operation in combustible dust atmospheres (i.e. saw dust, flour, etc.).
Humidity / Moisture: Units not for operation outdoors or in conditions where condensation forms.
Atmosphere: Units not for operation in explosive atmospheres (i.e. natural gas fumes, oil based paint fumes, etc.).
138 Chapter 11
XMU+ Technical Specifications and Approvals
Card Specifications
Technical Feature...
Details...
Control Card
Digital Audio Core Specifications:
Encoding /
Decoding:
Frequency
Response:
8 bit PCM / 8 KHz sampling / µ-law (no data compression)
200 - 3400 Hz (+/- 3 dB)
Working Memory: Up to 1.5Gbit on memory modules
Channel Capacity:
Core FPGA:
Large chassis: 64 channels non-blocking plus 1 remote channel
Small chassis: 24 channels using T1 line card or 8 channels using analog line card.
Xilinx Spartan II / 50K gate / proprietary logic
Processor Core Specifications:
Processor type:
Processor Memory:
Motorola MPC855T / 66 MHz core / 33 MHz bus / 3.3V
32Mbit NOR FLASH / 64Mbit SDRAM / up to 1.5Gbit
NAND FLASH on memory modules
Processor Firmware: Proprietary, with a Licensed Real Time Operating System
(RTOS)
Real Time Clock:
Accuracy: 2 minutes / year
Back-up power duration: 30 days
Port Specifications:
Remote: Compatible with global PSTN (FCC / IC / CTR-21)
Ring detection feature
DTMF detection feature
Loop current direction detection feature
Connector: RJ 11
Impedance: 600Ω nominal
Input Level (AGC onset): -30 dBm
Nominal Output Level: -9 dBm
Loop current: 10 mA - 60 mA (limiting)
Off Hook Loop Voltage: 40VDC maximum
Technical Feature...
Modem:
Alarm:
Serial Ports:
Network:
Tape:
XMU+ Installation and Maintenance Guide rev.07 139
Detailed XMU+ Technical Specifications
Details...
Compatible with global PSTN (FCC / IC / CTR-21)
56Kbps (V.90), 33.6Kbps (V.34), 14.4Kbps (V.32) + other modes
V.42 LAPM and MNP 2-4 error correction
V.42bis and MNP 5 data compression
Connector: RJ 11
Inputs: contact closure or applied DC voltage up to +/-
60V
Outputs: dry relay contacts (1 form “C” - NO/NC/
COM)
Output contacts: 1.0 A @ 30V / 0.5A @ 60V
(60V maximum)
Input current: 5 mA @ 60V (maximum)
Type: RS-232 Transmit and Receive data (software flow control required)
Data Rate: 115 Kbps (maximum)
Connector: RJ45 with proprietary pin-out
Input Impedance (typ): 5 KΩ
Input Voltage (low): -15 V to +1.2 V
Input Voltage (high): +1.5 V to +15 V
Output Voltage Swing (typ): +/- 5.4 V into 3 KΩ
Protection (ESD): +/- 15KV Human Body
+/- 15KV IEC1000-4-2 Air Discharge
Type: 10/100BaseTX Ethernet
IEEE 802.3 compliant (Auto Detect)
Connector: RJ-45 connector with standard pin-out
Impedance: 100Ω / matched for Category 5 UTP cable
Protection: 1500 V RMS Hipot
2000 W / 100 A 8/20µs pulse
Connector: 1/4" “microphone” jack
Impedance: 10 KΩ
Input level (AGC onset): 120mV
Nominal output level: 180 mV RMS (10 KΩ load)
140 Chapter 11
XMU+ Technical Specifications and Approvals
Technical Feature...
Handset:
Power Supply Cards
Input Voltage:
Output Voltages:
Hot Swap Features:
Details...
Connector: RJ 22
Input Impedance: 3.2 KΩ
Input level (AGC onset): 50 mV RMS
Input Bias: 5 VDC through 3.2 KΩ
Output Impedance: 6.8 KΩ
Nominal output level: 20 mV (200 Ω load)
Large AC: Auto ranging 100 - 240 V 50/60 Hz
Large DC: 40 - 60 VDC
Small AC: Auto ranging 90 - 264 V 50/60 Hz
Small DC: 38 - 60 VDC
Note: DC units are protected from accidental reverse polarity. See consumption data in
Power and Thermal on page 137.
Output voltages of +5, +12, and -5 V are supplied to the
XMU+ electronics.
Status indicator (green if all output voltages nominal)
Hot insertion / extraction management
Soft start
Status detection by control card
XMU+ Installation and Maintenance Guide rev.07 141
Detailed XMU+ Technical Specifications
Technical Feature...
Details...
Line Cards
Hybrid Analog (includes SH8 and MWR derivatives):
Connector:
Output Level:
Output Impedance:
Loop current:
RJ21
-15 dBm / -9 dBm (high volume)
600 Ω nominal (FCC / IC / CTR-21 compatible)
10 mA - 60 mA (limiting)
Off Hook Loop
Voltage:
Control Relay
Current:
40VDC maximum
100 mA maximum (60 VDC maximum)
Start Input (Voltage
Sense): 10 mA at 48 VDC (60 VDC maximum)
Start Input (Contact
Closure): 5 mA (maximum)
Low Impedance Analog
Connector:
Output Level:
Output Impedance:
RJ21
-15 dBm / -9 dBm (high volume)
25 ohms nominal (24 600 Ω ports in parallel)
10 mA - 60 mA (limited) Loop current:
Off Hook Loop
Voltage: 40VDC maximum
Control Relay
Current:
Start Input (Voltage
Sense):
1 A maximum (60 VDC maximum)
10 mA at 48 VDC (60 VDC maximum)
Start Input (Contact
Closure): 5 mA (maximum)
142 Chapter 11
XMU+ Technical Specifications and Approvals
Technical Feature...
Details...
Music on Hold (MOH) Card
Connectors:
Input Impedance:
RCA “phono” jacks
10 KΩ nominal
Input level (AGC onset):
Output Impedance:
-30 dBm (note: POTS / CO compatible)
User configurable: 8 or 600 Ω
Output Level: User configurable: -15, -9, +9 dBm (600 Ω) / 1 W (8 Ω)
See Applying MOH Line Card Settings on page 31 for an explanation of MOH
user configurable impedance and level settings.
T1 Digital Line Card
Connector:
Impedance:
Line length:
Signaling:
RJ45
100 ohm balanced
0-1000 ft.
Loop start (ring with loop disconnect)
E&M (immediate start, wink start)
Line Coding: AMI, B8ZS
Framing Format: SF/D4 (A & B bit)
ESF (A, B, C, D bit)
See Chapter 3 of the XMU+ Installation Handbook for an explanation of T1 card user configurable attributes.
XMU+ Installation and Maintenance Guide rev.07 143
XMU+ Approvals
XMU
+
Approvals
The following approvals information details the North American and European
Information Technology Equipment (ITE) standards with which the XMU+ conforms:
Safety Approvals: XMU+ compliance with safety standards.
Telecom Approvals: XMU+ compliance with telephone network standards.
Emissions Approvals: XMU+ compliance with radiated and conducted emission
(and immunity) standards.
Safety Approvals
TUV RHEINLAND TEST REPORTS E2172519/E2172521
CSA C22.2 No 60950 - 00 Safety: Information Technology Equipment (Canada)
UL 60950 - 3rd Edition Safety: Information Technology Equipment (US)
IEC 60950 - 1 Safety: Information Technology Equipment (CE)
Telecom Approvals
TUV RHEINLAND TEST REPORTS CS03/121001/01, Part 68/121002/01, TBR21/121001/
01
Industry Canada (IC) CS-
03
Terminal Equipment Standard (Canada) *
47 CFR Part 68 Terminal Equipment Standard (US)
TBR 21 (with AN 14, 15, 16) Terminal Equipment Standard (CE)
144 Chapter 11
XMU+ Technical Specifications and Approvals
Emissions Approvals
TUV RHEINLAND TEST REPORTS P2172520.01/P217222.01
FCC Part 15
FCC Part 15
EN550221: 1998
EN550221: 1998
EN61000-3-2
EN61000-3-3
EN61000-4
Radiated Emissions - Class A (North America)
Conducted Emissions - Class A (North America)
Radiated Emissions - Class A (CE) **
Conducted Emissions - Class A (CE) **
Harmonics - Class A (CE)
Flicker (CE)
Immunity (CE)
* The abbreviation “IC” before the registration number signifies that registration was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met. It does not imply that Industry Canada approved the equipment.
** This is a Class A product compatible with commercial/industrial environments. In a domestic environment, this product may cause radio interference that the user may be required to take adequate measures to control.
Glossary
Automatic Call Distribution (ACD)
The XMU+ can be configured for ACD applications, which automatically routes incoming calls to available personnel.
In front-ending ACD queues, XMU+ answers all incoming calls, checks caller requirements, forwards, and queues the caller into the appropriate queue.
In back-ending ACD queues, the client’s telephone system answers the call and places the user in the queue. XMU+ controls the queue, plays appropriate holding messages, and forwards the caller to the requested person when the line becomes available.
See
About the XMU+ Announcement and Call Processing
System on page 3 for more information.
Auto-Attendant
The XMU+ can be configured for Auto-Attendant applications, which provide:
Personalized, automated greetings to incoming callers.
A menu of choices.
Call forwarding.
See
About the XMU+ Announcement and Call Processing
Call Router
An XMU+ equipped with a Hybrid Analog line card can be configured to transfer callers to pre-programmed extensions or telephone numbers.
146 Glossary
Carrier Detect Indicator
The carrier detect indicator is associated with the modem port on the Control Card.
This indicator should be lit during data transfer by modem. It indicates that the local modem has detected the remote modem's carrier, which is a basic attribute of the data transmission.
Channels
Channels are the virtual assignment of T1 lines within a cable into separate lines.
Designating channels gives XMU+ the ability to use up to 24 lines on a T1 line card.
Chassis
The XMU+ large chassis provides flexible configuration options for users requiring 2 to
64 analog ports (48 T1 ports), while the
XMU+ small chassis provides an effective solution for users requiring 2 - 8 analog ports
(24 T1 ports).
See
Collision Indicator
The collision indicator is associated with the network (Ethernet) port on the Control card.
This indicator is on when a data collision on the network is detected. Such collisions will normally occur in Ethernet, but if too many are indicated the network may have too much traffic and/or too many devices on it. Such a network problem could be solved by subdividing the network with a switching hub.
Configurations
XMU configurations are composed of commands, nodes, messages, and music that are executed when a call is received.
Configurations are designed on XMUCOM+ software and then downloaded to the XMU+ unit.
See
About the XMU+ Announcement and
Call Processing System on page 3.
Control Pulse
A Control Pulse signal is provided to certain types of PBX equipment by the XMU+. This is used by those PBX types to detect the off hook condition (instead detecting loop current).
DS0
Digital Signal - Level Zero (0). In the digital communications hierarchy, this is the individual channel. The data rate is 64 Kbps
(the rate required to digitize a voice message).
DS1
Digital Signal - Level One (1). In the digital communications hierarchy, individual channels are bundled into basic multichannel groups called DS1. In North
America, DS1 equates to T1 service (24 channels x 64 Kbps + 8 Kbps control = 1.544
Mbps). In Europe, DS1 equates to E1 service
(30 channels x 64 Kbps + 128 Kbps control =
2.048 Mbps)
XMU+ Installation and Maintenance Guide rev.07 147
Dual Tone Multi Frequency (DTMF)
A telephone’s touch tone system uses pairs of tones to represent the various keys. There is a
“low tone” and a “high tone” associated with each button (0 through 9, * (star), and #
(pound)).
The XMU+ uses a DTMF node to identify the unique tones pressed by a caller on a touchtone telephone and route the call accordingly.
See
Typical Uses for XMU+ on page 7 for
more information.
Ethernet
Ethernet is a popular Local Area Network
(LAN) type originally introduced by Xerox and now supported by an IEEE standard.
Ethernet uses a Carrier Sense Multiple Access
/ Collision Detect (CSMA/CD) technique to accommodate multiple devices on a common medium such as twisted pair cable. The
XMU+ Control Card network port is an
Ethernet port. It supports data transfer at 10 or 100 Mbps (less control “overhead”).
Hot Swap
Cards with hot swap capability can be changed while the XMU+ system is operating. Line cards and power supply cards are hot swap types. For line cards, only those channels connected to the card to be removed and replaced are disrupted (or need to be taken out of service). Power supply cards can be swapped with no disruption to system operation so long as there is a second
(redundant) power supply card.
Hybrid Analog
A hybrid analog line card incorporates both passive (ring detect, start signal detect, control pulse) and interactive (DTMF detect) announcement functionality.
Lines
Lines are the telephone lines (extensions) that can connect to the XMU+.
Link Indicator
The link indicator is associated with the network (Ethernet) port on the Control Card.
This indicator is on when the port is connected to an active Ethernet network.
Loop Current
For PSTN lines and certain PBX equipment types, the current that flows in the audio pair when the terminal equipment (XMU+ line card port) is off hook is detected and used for control purposes.
Low Impedance
The Low Impedance card is a variant of the hybrid analog line card specially equipped to drive audio and signaling to 24 RAN
(Recorded Announcement) ports in parallel on Nortel Meridian PBX equipment.
Memory Module
Memory Modules reside on the Control Card, and provide working and non-volatile memory storage for messages and configurations within the XMU+. Memory
Modules are replaceable and upgradeable.
See
Upgrading Control Card Memory on page 116.
Mini Weather Radio (MWR)
The MWR line card is used for Environment
Canada weather broadcasting applications.
See
Line Cards Supported by XMU+ on page 5.
Modem
A device for transferring digital data over analog telephone lines. Modem is the
148 Glossary contraction of the words MODulator
DEModulator.
Music on Hold (MOH)
An XMU+ equipped with a Music On Hold
(MOH) line card can be set up to combine music and messages to create an On Hold environment for your callers.
See
Applying MOH Line Card Settings on page 31.
Node
XMU building blocks consisting of a group of commands or XMU settings that are used to build XMU+ configurations.
See
About the XMU+ Announcement and
Call Processing System on page 3.
Partition
The XMU+ can be configured for single or multi-partition mode. When multi-partitioning is configured, each partition acts as an individual XMU+ unit.
See
Meeting System Requirements on page 16.
Passive announcements
Passive announcements are those configured to simply playout with a ring or control pulse start then disconnect. DTMF detection is not used during a passive announcement.
Port
A female connector on the XMU+ for connecting the (male) connector of various external devices.
Private Branch Exchange (PBX)
This is typically a private telephone network used within an enterprise. Users of the PBX share a certain number of outside lines for making telephone calls external to the PBX.
Public Switched Telephone Network
(PSTN)
The public telephone system that operates the normal phone system.
Start Signal
Certain types of PBX equipment provide a start signal to the XMU+. This is used instead of a conventional ring signal superimposed on the audio pair.
T1
T1 is a North American high-speed, dedicated “DS1” connection that is capable of transferring digital signals at 1.554 Mbps
(mega-bits per second). The payload of a T1 connection is twenty-four (24) 64 Kbps “DS0” voice channels.
Uniform Call Distribution (UCD)
The XMU+ can be configured for UCD applications, which distributes all incoming calls uniformly among a group of people.
See
About the XMU+ Announcement and
Call Processing System on page 3.
Uninterruptible Power Supply (UPS)
The XMU+ can be connected to a UPS, which will maintain the XMU+ for a limited time in case of a power failure.
See
Power Requirements on page 17.
XMU+ Installation and Maintenance Guide rev.07 149
XMU+
The XMU+ Digital Call Processor is a microprocessor based, voice announcement and call processing system.
XMUCOM+
The XMUCOM+ software is a windows based program that lets you configure, download, update, and backup configurations and messages to the XMU+.
Configurations designed with XMUCOM+ are transmitted to the XMU+ unit through a modem connection or through LAN based networks.
150 Glossary
Index
A
AC power
ensuring circuits are functional 128
safety
access codes about
entering
messages
partition
system
ACD applications about
PBX interface table
,
,
,
with hybrid analog line cards
with low impedance line cards
adding memory
alarms about
cabling
port location on control card
responding to
technical specifications
troubleshooting
Amphenol see RJ-21
announcers interactive
APP image see firmware
approvals
152 Index registration
safety
telecom
audio testing
audiotex applications with hybrid analog line cards
auto attendant applications about
PBX interface table
with hybrid analog line cards
automatic call distribution see ACD applications
B
backup configuration
messages
before you start cabling
system requirements
C
cables color abbreviations
hybrid analog line cards
matching to connectors
MOH line cards
MWR line cards
cabling about
alarms
control card
flowchart
hybrid analog line cards
line cards
54 low impedance line cards 54
modem connection to XMUCOM+ 49
MOH line cards
network (direct) connection to XMU-
COM+
network (LAN) connection to XMU-
COM+
T1 line cards
call processing applications
DTMF
with hybrid analog line cards
call routing applications
with hybrid analog line cards
cards see line cards
channels
about DS0
about DS1
checking system configuration
checklists
control card specifications
delivery
,
firmware
hybrid analog hardware settings
installation specifications
line cards installed
messages
MOH hardware settings
PBX requirements
power supply specifications
telephone numbers and extensions 25
communication checklist
XMU+ Installation and Maintenance Guide rev.07 153
configurations about
backing up
checking message integrity 125
checking startup
loading
messages
specifications
connections remote telephone access
testing
to XMUCOM+
connectors hybrid analog line cards
matching to cables
MOH line cards
MWR line cards
pinouts
RCA/phono
RJ-21
continuous play operating mode
control card about
cabling
checklist
hot swap
modem port
network port
remote access port
removing
serial port
specifications
technical specifications
upgrading
upgrading memory
D
date
verifying
DC power
ensuring circuits are functional 128
requirements
digital signals about DS0
about DS1
direct connection
DTMF applications
with hybrid analog line card
dual tone multi-frequency
E
environmental
HVAC requirements
optimum temperatures
shelf space
technical specifications
Ethernet
assign IP address
collision indicator
ping IP address
status indicator
testing connection
F
features front panel
rear panel
XMU+
firmware
multiple partition hierarchy
selecting APP image
selecting previous version
154 Index single partition hierarchy
flowcharts
cabling XMU+
installation guide
line card hardware settings
testing setup
troubleshooting if XMU+ is not answering
troubleshooting XMU+ hardware failures
XMU+ installation
front panel about
arrow keys
assign IP address
assign messages to a line
card
cards
change access code
delete message
firmware hierarchy
large chassis
messages
navigating
nodes
partition
play message 83 record message 83
set remote access mode
setting operating modes
small chassis
system
,
tape deck input/output
time and date
using
I
H
handset connecting to XMU+
technical specifications
hardware
hybrid analog line cards
cables
cabling
checklists
connector
connector pinouts
DTMF call processing applications
hardware settings
installing
interactive announcements
part numbers
passive announcements
technical specifications
,
installation before you start
checklist
troubleshooting
installing
,
single power supply
XMU+ unit in a rack
XMU+ unit to a wall
integrity check messages
interactive applications about
7 with hybrid analog line card 7
IP
ping address
J
jumpers
L
language
large chassis about
front panel
level start operating mode
line cards assigning messages
cabling
checklist
front panel
hardware settings
hardware settings flowchart 29
hot swap
hybrid analog
low impedance
menu
MOH
,
operating mode
part numbers
PBX requirements
population rules
removing
setting jumpers
XMU+ Installation and Maintenance Guide rev.07 155 setting operating modes
setting ring limit
status indicators
T1
troubleshooting
upgrading
verify wiring
verifying operation
lines
about
checking
testing
low impedance line cards about
,
connector
connector pinouts
installing
passive announcements
PBX interface table
technical specifications
uses for
M
main menu
multiple partition mode
single partition mode
matching connector pinouts
connectors and cables
memory about
adding
reset
upgrading
menus card
156 Index
partition
system
,
messages assign to a line
backing up
checking against configurations
checklist
delete with remote access
front panel
menu
play with remote access
record with remote access
remote access
troubleshooting
mini weather radio applications about
PBX interface table
modems about
,
cabling
port location on control card
status indicator
technical specifications
MOH line cards about
cabling
connector
hardware settings
jumpers
part numbers
PBX interface table
population rules
setting jumpers
technical specifications
uses for
,
mounting
XMU+ in a rack
XMU+ to a wall
multiple partitions card menu
partition menu
system menu
multiple play
music on hold applications
music sources
with MOH line cards
MWR line cards
cables
cabling
connector
connector pinouts
installing
part numbers
uses for
N
navigation flowcharts
network connection
cabling direct 50 cabling LAN 50
collision indicator
port location on control card 47
technical specifications
nodes
menu
XMU+ Installation and Maintenance Guide rev.07 157
O
operating modes checking
continuous play
level start
level start/level return - single play
level start/pulse return - multiple play
level start/pulse return - single play
line card
pulse start
pulse start/level return
pulse start/pulse return
ring
ring start without loop current check 70
single play
synchronized continuous play
P
partitions about
checking with front panel
multiple
number available
single
passive applications about
with hybrid analog line cards 7
PBX with low impedance line cards
about
checklist
control pulse signal
interface tables (see PBX interface tables)
requirements
verifying timing
PBX interface tables
ACD applications
auto attendant 56 call processing 56
for hybrid analog line cards
,
for low impedance line cards
for MOH line cards
MOH applications
MWR applications
pinouts
RJ-21
population rules line cards
ports
power requirements
UPS
power supply checking circuits
checklist
installing
removing
replacing
technical specifications 137 ,
testing
upgrading
UPS
private branch exchange see PBX
158 Index processor technical specifications
pulse start operating mode
R
RCA/phono connector
rear panel
recording messages input/output
remote access about
,
accessing XMU+
cabling
change access code
change language
delete message
disconnecting from XMU+
messages
port location on control card
set access mode
using
removing control card
line cards
secondary power supply
replacing memory
requirements environmental
meeting
reset
firmware
flash memory
ring limit
ring start line check
operating mode
RJ-21 connector pinout
S
safety
AC power
DC power
,
installer qualifications
,
standard static discharge precautions
serial ports location on control card
setting up
Ethernet (direct) communication 50
Ethernet (LAN) communication
modem communication
single partition card menu
main menu
message menu
node menu
system menu
single play operating mode
small chassis
XMU+ Installation and Maintenance Guide rev.07 159 front panel
static
,
status checking lines
modem indicator
network indicator
power supply indicators
system
front panel
menu
standard reset
technical specifications
testing
troubleshooting
system requirements environmental
PBX
power
T
T1 applications about channels
with T1 line cards
T1 line cards about
cabling
connector
hardware settings
part numbers
population rules
technical specifications
troubleshooting
tape
technical specifications
technical specifications alarm
control card
low impedance line card
network
physical
ports
power and thermal
power supply card
processor
tape
telephone lines
PSTN system
testing audio
Ethernet communication
flowchart
installation
line connections
sound
system health
system power
time telephone lines
verifying
troubleshooting audio
installation
line cards
messages
operating modes
power supply failures
XMU+ alarms
160 Index
U
UCD applications about
PBX interface table
,
,
with hybrid analog line cards
with low impedance line cards
uniform call distribution
uninterruptible power supply see UPS
upgrading control card
line cards
memory
power supply
UPS about
V
verifying
PBX/line card timing
time and date
voice encoding/decoding about
W
weather broadcasting applications
X
XMU+ about
bring online after maintenance 108
cabling
compiling and providing information
default language
factory reset
large chassis
line cards
mounting to a wall
navigation
nodes
operating modes
processor
quick reset
rear panel
standard reset
system check
system requirements
technical specifications
upgrades
uses for
XMUCOM+
connecting with modem connection
connecting with network (direct) connection
connecting with network (LAN) connection
XMU+ Installation and Maintenance Guide rev.07 161
162 Index
End User License Agreement
Limited Warranty Interalia® warrants this equipment to be free of defects in material and workmanship for a period of one year from the date of shipment. All defects will be repaired without charge upon return of the unit to the factory.
This warranty is null and void if any modifications have been made to the unit or if the unit has been subject to physical or electrical stress as determined by the manufacturer.
This warranty covers parts and labour only and does not include shipping costs, traveling expenses or travel time.
Installation of the equipment is the sole responsibility of the purchaser. The manufacturer, its agents or distributors, accept no responsibility for malfunction or damage caused by improper connection of the unit.
THE MANUFACTURER, ITS AGENT OR DISTRIBUTORS,
ARE NOT LIABLE FOR LOSSES INCURRED THROUGH
THE USE OF THE EQUIPMENT, OR BY THE
MALFUNCTION OF THE EQUIPMENT, OR FOR ANY
LOSSES OR DAMAGE INCURRED BY THE USE OF THE
EQUIPMENT IN ANY MEANS WHATSOEVER.
THIS WARRANTY IS LIMITED TO THE REPAIR OF THE
EQUIPMENT TO ITS NORMAL FUNCTIONAL CAPABILITY.
THIS WARRANTY IS COMPLETE AS STATED AND ALL
OTHER WARRANTIES, EXPRESSED OR IMPLIED, ARE
NOT VALID.
Important Read Carefully
This End-User License Agreement is a legal agreement between you (either an individual or a single entity) and Interalia®. This legal agreement is specific for the XMU+ hardware and software that you ha ve purchased.
Software Product License
1. Grant of License. This grants you the following rights.
Software: You may install and use one copy of the software product on the computer.
Storage Use: You may also store or install a copy of the software product on the computer to allow other computers within your company to use the software product over an internal network. However, you must acquire and dedicate a license for the software product for each computer on which the software product is used. A license for the software product may not be shared or used concurrently on different computers.
Back up Utility: You may create a back-up copy of the software product solely for archival purposes.
2. Description of Other Rights and Limitations.
Limitations on Reverse Engineering, Decompilation and Disassembly. You may not reverse engineer, decompile, or disassemble the software package, except and only to the extent that such activity is expressly permitted by application law notwithstanding this limitation.
Termination. Without prejudice to any other rights, Interalia® may terminate this agreement if you fail to comply with the terms and conditions of this agreement. In such event, you must destroy all copies of the software product and all of its component parts.
3. Upgrades: If the software product is an upgrade from a previous version, you may use or transfer the Software Product only in conjunction with that upgraded product.
4. Copyright: All title and copyrights in and to the software product and accompanying printed materials, and any copies of the software product, are owned by Interalia®. You may not copy the printed material accompanying the software product.
General Public Licence
Interalia Inc. offers any third party a complete machine-readable copy of the open source code used in this product. Code can be downloaded from: http://support.interalia.com/gpl
For over 34 years Interalia has been
a global leader in the design and
manufacture of high quality audio announcement solutions for the
telecommunication and transportation markets. During this time we have
installed more than 250,000 systems
in 60 countries around the world.
Interalia recognizes that to
be successful today we need to
listen to our customer’s suggestions and implement them in our products.
Our solutions are the result
of collective input from our
Customers and the engineering excellence Interalia has become
known for over the last 34 years.
4110 - 79th Street N.W.
Calgary, Alberta
Canada T3B 5C2
Tel: +1 403 288 2706
Fax: +1 403 288 5935 [email protected]
10340 Viking Drive, Suite 135
Eden Prairie, Minnesota
U.S.A. 55344
Tel: +1 952 942 6088
Fax: +1 952 942 6172 [email protected]
Bridge End Road
Grantham, Lincolnshire
England NG31 7TS
Tel: +44 (0) 1476 594207
Fax: +44 (0) 1476 594208 [email protected]
www.interalia.com
Download
Advertisement
Key features
Modular design
Field upgradeable
Remote management via modem or Ethernet
Two chassis sizes
ACD/UCD, Interactive Auto Attendant, DTMF Call Processing, and Music On Hold capabilities
XMUCOM+ software for configuration and management
Frequently asked questions
The XMU+ comes in two sizes: a large chassis and a small chassis.
The XMU+ supports a variety of line cards, including Hybrid Analog, Low Impedance, T1, and MOH line cards.
The XMU+ can be configured and managed from the front panel, using the XMUCOM+ software, or through remote access via a modem or Ethernet connection.
The XMU+ supports a variety of operating modes, including Continuous Play (CP), Synchronized Continuous Play (SCP), Level Start/Pulse Return – Single Play (LS/PR-SP), Level Start/Pulse Return – Multiple Play (LS/PR-MP), Level Start/Level Return – Single Play (LS/LR-SP), Pulse Start/Level Return (PS/LR), Pulse Start/Pulse Return (PS/PR), Ring Start (R), Ring Start without Loop Current Check (RN), Ring Start/Tone Disconnect (RT), Ring Start/DTMF Disconnect (RD), Ring Start/Busy Disconnect (RB), Ring Start/Quick Answer (RQ), Ring Immediate (RI).
To test the XMU+ after installation, you can verify system power, set time and date, assign and test IP addresses, test line connections, and perform an audio test.