Xstream HL060F, HL125F propane forced air heater Operation manual
BE HL060F is a Propane Forced Air Heater. Below you will find brief product information to help you understand its capabilities:
-
The BE HL060F is a powerful heater that produces up to 60,000 BTU of heat, making it ideal for heating large, open areas such as construction sites, warehouses, and workshops. It features a durable steel construction that can withstand harsh conditions.
-
The HL060F is easy to use, with a simple on/off switch and adjustable thermostat. It also has a built-in fan that helps to circulate the heat evenly, providing consistent warmth throughout the space.
-
The heater is equipped with safety features such as a flame failure safety device and an overheat protection system to ensure safe operation. It also has a long-lasting piezo igniter that provides reliable ignition every time.
Iklan
Iklan
PROPANE FORCED AIR
HEATER
operation manual
HL060F
HL125F
2
table of contents
Safety
6 Safety Rules
7 Safety Warnings
Features
11 Features
Assembly
12 Components
12 Assembling Frame and Wheels
Operation
14 Kerosene (1-K)
14 Theory of Operation
15 Fueling Your Heater
15 Clearances
16 Ventilation
16 Starting the Heater
17 Stopping the Heater
17 Restarting the Heater
18 Long-Term Storage of the Heater
Maintenance
19 Fuel Tank
19 Fan Blades
19 Nozzle
20 Spark Plug
21 Photocell
21 Fuel Filter
22 Pump Pressure Adjustment
23 Air Bleed Directions
Troubleshooting
24 Troubleshooting Chart
3
introduction
Attention: Read through the complete manual prior to the initial use of your
Compressor
Using the Operator’s manual
The operating manual is an important part of your Heater and should be read thoroughly before initial use, and referred to often to make sure adequate safety and service concerns are being addressed.
Reading the owner’s manual thoroughly will help avoid any personal injury or damage to your heater. By knowing how best to operate this machine you will be better positioned to show others who may also operate the unit.
You can refer back to the manual at any time to help troubleshoot any specific operating functions, so store it with the machine at all times.
4
product identification
Record Identification Numbers
Heater
If you need to contact an Authorized Dealer or Customer Service line (1-
866-770-1711) for information on servicing, always provide the product model and identification numbers.
You will need to locate the model and serial number for the heater and record the information in the places provided below.
Date of Purchase:
Dealer Name:
Dealer Phone:
Product Identification Numbers
Model Number:
Serial Number:
5
safety
Save these Instructions
SAFETy RUlES
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
The safety alert symbol ( ) is used with a signal word (DANGER,
CAUTION, WARNING), a pictorial and/or a safety message to alert you to hazards.
DANGER indicates a hazard which, if not avoided, will result in death or serious injury.
WARNING indicates a hazard which, if not avoided, could result in death or serious injury.
CAUTION indicates a hazard which, if not avoided, might result in minor or moderate injury.
NOTICE indicates a situation that could result in equipment damage.
Follow safety messages to avoid or reduce the risk of injury or death.
Hazard Symbols and Meanings explosion fire hot surface moving parts flying objects electric shock toxic fumes injection
6
safety
WARNING
• FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP
COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR
CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS
RECOMMENDED BY THESE INSTRUCTIONS. NEVER USE THE
HEATER IN SPACES WHICH CONTAIN PRODUCTS SUCH AS
GASOLINE, SOLVENTS, PAINT THINNERS, DUST PARTICLES,
VOLATILE OR AIRBORNE COMBUSTIBLES, OR ANY UNKNOWN
CHEMICALS.
WARNING
• NOT FOR HOME OR RECREATIONAL USE.
WARNING
• CALIFORNIA RESIDENTS: Combustion by-products produced when using this product contain carbon monoxide, a chemical known to the state of California to cause cancer and birth defects (or other reproductive harm).
WARNING
• Do not operate this heater until you have read, and thoroughly understand these safety and operating instructions.
WARNING
• FAILURE TO COMPLY WITH THE PRECAUTIONS AND
INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT
IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS
OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN.
ASPHYXIATION, CARBON MONOXIDE POISONING AND / OR
ELECTRIC SHOCK. ONLY PERSONS WHO CAN UNDERSTAND
AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE
THIS HEATER. IF YOU NEED ASSISTANCE OR HEATER
INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABEL,
ETC. CONTACT THE MANUFACTURER.
7
8 safety
WARNING
• Carbon Monoxide Hazard This heater produces carbon monoxide, which has no odor. Burning the heater in an enclosed space can kill you. Never use the heater in enclosed spaces such as a tent, a camper, any vehicle or recreational vehicle (RV), enclosed shelter, or any other enclosed areas.
DANGER
• Not for use in residential living areas or in non-adequately ventilated enclosed spaces. Never bring or store a propane cylinder indoors.
DANGER
• If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
WARNING
• This is an unvented portable heater. It uses air (oxygen) from the area in which it is used. Adequate combustion and ventilation air must be provided. Refer to VENTILATION on Page 5.
WHAT TO DO IF THE SMELL OF GAS IS PRESENT:
• DO NOT attempt to light heater.
• Extinguish any open flame.
• Shut off gas to heater.
• If odor continues, contact your local gas supplier or fire department.
• Do not touch any electric switch, do not use any. Immediately call your gas supplier from a neighbors phone. Follow the gas suppliers instructions.
• If you can not reach your gas supplier, call the fire department.
• Service must be done by a qualified service agency or the gas supplier.
safety
This heater is designed and approved for use as a construction heater in accordance with Standard ANSI Z83.7-2011/CSA 2.14-2011. CHECK
WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE ANY
QUESTIONS ABOUT APPLICATIONS. Other standards govern the use of fuel gases and heating products for specific uses. Your local authority can advise you about these.
The primary purpose of construction heaters is to provide temporary heating of buildings under construction, alteration, or repair. Properly used, the heater provides safe economical heating. Products of combustion are vented into the area being heated.
IMPORTANT: Read this User’s Manual carefully and completely before attempting to operate, assemble, or service this heater. Improper use of the heater can cause serious injury or death from fire,explosion and carbon monoxide poisoning. Every possible circumstance that may involve a hazard cannot be anticipated. The warnings in this manual and attached to the unit are therefore not all-inclusive. If a procedure, work method or operating technique not specifically recommended by BE
Pressure is used, you must be sure it is safe for you and others. You should also insure that equipment will not be damaged or made unsafe by the operating or maintenance method you choose.
This is a direct-fired, forced-air construction heater for either indoor or outdoor use. It’s intended use is primarily for the temporary heating of buildings under construction, alteration or repair. All of the products of combustion generated by this heater are forced through the heater and released into the area being heated. This heater operates at approximately 98%+ combustion efficiency, but still produces small amounts of carbon monoxide. Humans can tolerate small amounts of carbon monoxide for short periods. Carbon monoxide can build up in a heated space, and failure to provide adequate ventilation could result in poisoning or death.
You must provide the propane gas and cylinder(s). Use this heater only with a propane vapor withdrawal supply system. Refer to Chapter 5 of the Standard for Storage and Handling of Liquefied Petroleum Gas ,
ANSI/NFPA 58. Your local library or fire department will have this booklet.
• Children should be kept away.
• Always maintain proper clearance from combustible materials. Minimum clearance should be:
Sides - 24” Top - 36” Front - 72”
• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
9
safety
• An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
• Heater must be placed on level and solid footing.
• Never place anything, including clothes or other flammable items on heater.
• Do not modify heater, or operate a heater that has been modified.
• Adequate clearance for accessibility, combustion and ventilation (air supply) must be maintained at all times when heater is operating.
• Service and repair should be performed by a qualified service person.
The heater should be inspected before each use, and at least annually by a qualified person. More frequent cleaning may be required as necessary. Do not service heater while hot or operating.
• Never connect heater to an unregulated gas supply.
• This heater is equipped with a 3-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
• Use only the electrical/power cord specified. Electrical and grounding connection must comply with National Electrical Code - ANSI/NFPA 70
(USA) and CSA C22.1 Canadian Electrical Code, Part 1 (Canada).
• To prevent injury, always wear gloves when handling heater. Never handle an operating or hot heater, as severe burns may result.
• Use heater in accordance with all local codes. In the absence of local codes, refer to The National Fuel Code, ANSI Z223.1.
• This heater is shipped from the factory for use with LP (propane) gas only. Do not convert to any other gas. Installation must conform to local codes, or in their absence, with the standard for the Storage and
Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and the Natural
Gas and Propane Installation Code 149.1.
• Use only the regulator and hose assembly provided with this heater.
Inspect the regulator/hose assembly prior to each use of the heater. If there is excessive abrasion or wear, or if the hose is cut, replace it with the proper assembly shown in the parts list, prior to using the heater.
• Gas supply connections should be checked by using a 50/50 soap and water solution. Never use a flame to check for gas leaks.
• Locate LP cylinder at least 6 feet (10 ft. in Canada) from the heater, and do not direct heater discharge towards the LP cylinder unless it is at least 20 feet from the heater.
• The electrical connection and grounding must comply with the National
Electrical Code, ANSI/NFPA 70 and CSA C22.1 Canadian Electrical
Code, Part 1 (Canada) Canadian Electrical Code, Part 1. Use only a properly grounded three (3) prong receptacle.
• Do not restrict air inlet or outlet areas of the heater.
10
features
WARNING
• The hose assembly shall be pro tected from traffic, building material and contact with hot surfaces both during use and while in storage.
• Not for use with ductwork.
WARNING
Min.
Max.
Minimum and Maximum inlet Pressure
HL060F HL125F
5 PSI
Bottle Pressure
UNPACKING
1. Remove all packing items applied to heater for shipment. Keep plastic cover caps attached to inlet connector and hose/regulator assembly for storage.
2. Remove all items from carton.
3. Check all items for shipping damage. If heater is damaged, promptly inform dealer where you purchased the heater
CAUTION
• The Propane (LP) gas pressure regulator and hose assembly supplied with the heater must be used without alteration.
11
features
NEVER LEAVE HEATER UNATTENDED
WHILE BURNING, CONNECTED TO A
POWER SOURCE, OR WHILE
CONNECTED TO A FUEL SOURCE
Features
- 100% safety shut-off system.
- Adjustable input ratings (Except PT-40-GFA-A).
- Adjustable Height Controller.
PROPANE
• Wind resistant and rain protected.
• Continuous spark ignition or piezo spark ignition.
• 100% safety shut-off system.
• Adjustable input ratings
• Adjustable Height Controller.
specified in the American National Standard for Compressed
Gas Cylinder Valve Outlets and Inlet Connections.
- A safety relief valve having direct communications with the vapor space of the LP cylinder.
Liquefied Petroleum Gas , ANSI/NFPA 58. Your local library or fire department will have this booklet.
- An arrangement of vapor withdrawal.
The amount of LPG used with this heater varies. Both factors are:
LP Characteristics:
- Flammable, explosive under pressure, heavier than air, and pools in low areas.
1. The amount of gas in the cylinder of LPG.
2. The temperature of the LP tank and its surroundings.
- In its natural state, propane has no odor, but for your safety an odorant that smells like rotten cabbage has been added.
- Contact of propane (LP) gas with the skin can cause freeze burns.
Average
Temp
(°F)
PT-40
20 or 100 lb. cylinder
PT-60V
20 or 100 lb. cylinder
PT-125V
100 lb. cylinder
PT-150V
100 lb. cylinder
- Heater is manufactured for use with LP gas only. DO NOT attempt to convert to any other gas. Such modifications are dangerous, and will void warranty.
32°
20°
1 1 2 2
- When heater is not in use, LP cylinder must be turned OFF
1 1 2 2
- Be sure that the LP cylinder is located on a level and stable surface.
10°
0°
1
1
1
1
3
3
3
3
- Do not use this heater in a basement or below ground level.
Propane (LP) is heavier than air, and will always seek the lowest level. If you suspect a leak, shut off the valve at the LP cylinder immediately.
The Propane (LP) cylinder must also be equipped with the following:
- A collar to protect the gas valve.
- A shut-off valve terminating a LP cylinder valve outlet as
-10°
-20°
2
2
2
2
Use Larger
Tank
Use Larger
Tank
Use Larger
Tank
Use Larger
Tank
Figure 2: The table above shows the minimum number of 100 lb LP cylinders required in cold weather. Your local
LP dealer will help you select the proper LP supply system.
© 2012, Pinnacle Products International, Inc.
4 Propane Forced Air User’s Manual
12
propane supply/information
Propane Supply/Information
PROPANE
You must provide the propane gas and cylinder(s). Use this heater only with a propane vapor withdrawal supply system. Refer to Chapter 5 of the Standard for Storage and Handling of Liquefied Petroleum Gas ,
ANSI/NFPA 58. Your local library or fire department will have this booklet.
lP Characteristics:
• Flammable, explosive under pressure, heavier than air, and pools in low areas.
• In its natural state, propane has no odor, but for your safety an odorant that smells like rotten cabbage has been added.
• Contact of propane (LP) gas with the skin can cause freeze burns.
• Heater is manufactured for use with LP gas only. DO NOT attempt to convert to any other gas. Such modifications are dangerous, and will void warranty.
• When heater is not in use, LP cylinder must be turned OFF
• Be sure that the LP cylinder is located on a level and stable surface.
• Do not use this heater in a basement or below ground level. Propane
(LP) is heavier than air, and will always seek the lowest level. If you suspect a leak, shut off the valve at the LP cylinder immediately.
The Propane (LP) cylinder must also be equipped with the following:
• A collar to protect the gas valve.
• A shut-off valve terminating a LP cylinder valve outlet as specified in the American National Standard for Compressed Gas Cylinder Valve
Outlets and Inlet Connections.
• A safety relief valve having direct communications with the vapor space of the LP cylinder.
• An arrangement of vapor withdrawal.
The amount of LPG used with this heater varies. Both factors are:
1. The amount of gas in the cylinder of LPG.
2. The temperature of the LP tank and its surroundings.
Av. Temp
(°F)
HL060F
HL125F
32°
1
2
20°
1
2
10°
1
3
0°
1
3
-10°
2
Use larger tank
-20°
2
Use larger tank
The table above shows the minimum number of 100 lb LP cylinders required in cold weather. Your local LP dealer will help you select the proper LP supply system.
13
propane supply/information
CAUTION
• Propane is safe to use when properly handled. Careless handling of the LP cylinder could result in a fire and/or an explosion.
• Always keep LP cylinder securely fastened and in an upright position.
• Avoid tipping the LP cylinder on its side when connected to a regulator, since this may cause damage to the diaphragm in the regulator.
• Handle valves with care.
• Never connect an unregulated LP cylinder to a construction heater.
• Do not subject LP cylinder to excessive heat.
• Tightly close the gas shutoff valve on the LP cylinder after each use.
• All fittings must be protected when disconnected from the LP cylinder.
• Never store an LP cylinder inside a building or in the vicinity of any gas burning appliance.
CAUTION
• The disconnected tank must never be stored in a building, garage or any other enclosed area.
• Do not restrict inlet or outlet of heater. Heater is never to be used with duct work.
14
NEVER LEAVE HEATER UNATTENDED
WHILE BURNING, CONNECTED TO A
POWER SOURCE, OR WHILE
CONNECTED TO A FUEL SOURCE
Propane Supply / Information (Continued)
CAUTION
Propane is safe to use when properly handled. Careless handling of the LP cylinder could result in a fire and/or an explosion. Therefore:
- Always keep LP cylinder securely fastened and in an upright position.
pre-lighting instructions
regulator.
- Handle valves with care.
- Never connect an unregulated LP cylinder to a construction heater.
Pre-lighting Instructions
- Tightly close the gas shutoff valve on the LP cylinder after each use.
- All fittings must be protected when disconnected from the LP cylinder.
- Never store an LP cylinder inside a building or in the vicinity of any gas burning appliance.
CAUTION enclosed area.
The disconnected tank must never be stored in a building, garage or any other
- Do not restrict inlet or outlet of heater. Heater is never to be used with ductwork.
CONNECTING THE lP CylINDER
All new LP cylinders must be purged before the first filling.
CONNECTING THE LP CYLINDER
ALL NEW LP CYLINDERS MUST BE PURGED BEFORE THE
FIRST FILLING.
WARNING
WARNING
Purging and filling of LP cylinders must be performed by personnel who have explosion, fire, severe personal injury or death.
- Fasten full Propane tank and connect proper fitting to LP cylinder valve by turning COUNTERCLOCKWISE.
- With heater gas valve knob still in OFF position, turn ON LP
• Purging and filling of LP cylinders must be performed by personnel who have been thoroughly trained in accepted LP gas industry procedures. Failure to follow these instructions may result in water. Apply this solution to all gas connections. If bubbles appear, there is a leak. If a leak is found, turn off the gas supply,
• Turn heater gas valve knob and LP cylinder valve to OFF position.
• LP cylinder valve equipped with old style fitting has LEFTHANDED
8460.
- Have your LP cylinder filled by your local Propane gas supplier.
- The installation of this heater must meet all local codes and/or
Protect this fitting when disconnected from LP cylinder.
• Have your LP cylinder filled by your local Propane gas supplier.
• Some LP cylinders have a bleed-off valve. This valve should be inspected for leaks after each filling of the LP cylinder. Turn the valve clockwise to close.
Connecting the Hose
/ Regulator to the LP
Cylinder
Figure 3: Connecting the Hose / Regulator to the LP Cylinder
© 2012, Pinnacle Products International, Inc.
5
Figure 4: Connecting the Hose to Heater Inlet
Propane Forced Air User’s Manual
15
NEVER LEAVE HEATER UNATTENDED
WHILE BURNING, CONNECTED TO A
POWER SOURCE, OR WHILE
CONNECTED TO A FUEL SOURCE
Propane Supply / Information (Continued)
CAUTION Propane is safe to use when properly handled. Careless handling of the LP cylinder could result in a fire and/or an explosion. Therefore:
- Always keep LP cylinder securely fastened and in an upright position.
- Avoid tipping the LP cylinder on its side when connected to a regulator, since this may cause damage to the dia phragm in the regulator.
- Handle valves with care.
- Never connect an unregulated LP cylinder to a construction heater.
- Do not subject LP cylinder to excessive heat.
- Tightly close the gas shutoff valve on the LP cylinder after each use.
- All fittings must be protected when disconnected from the LP cylinder.
- Never store an LP cylinder inside a building or in the vicinity of any gas burning appliance.
CAUTION enclosed area.
The disconnected tank must never be stored in a building, garage or any other
- Do not restrict inlet or outlet of heater. Heater is never to be used with ductwork.
pre-lighting instructions
Pre-Lighting Instructions
CONNECTING THE LP CYLINDER - Fasten full Propane tank and connect proper fitting to LP
ALL NEW LP CYLINDERS MUST BE PURGED BEFORE THE
FIRST FILLING.
WARNING
Purging and filling of LP cylinders must be performed by personnel who have been thoroughly trained in accepted LP gas industry procedures. Failure to follow these instructions may result in ex plosion, fire, severe personal injury or death.
- Turn heater gas valve knob and LP cylinder valve to OFF position.
- LP cylinder valve equipped with old style fitting has LEFT-
HANDED THREADS. Turn fitting CLOCKWISE to loosen.
Protect this fitting when disconnected from LP cylinder.
- Have your LP cylinder filled by your local Propane gas supplier.
• Fasten full Propane tank and connect proper fitting to LP cylinder valve by turning COUNTERCLOCKWISE.
• With heater gas valve knob still in OFF position, turn ON LP cylinder valve and check for leaks with soap solution.
- To check for leaks, make up a 50/50 solution of dish soap and water. Apply this solution to all gas connections. If bubbles
CHECKING FOR LEAKS
• To check for leaks, make up a 50/50 solution of dish soap and water.
Apply this solution to all gas connections. If bubbles appear, there is a leak. If a leak is found, turn off the gas supply, and re-connect the
- Some LP cylinders have a bleed-off valve. This valve should be inspected for leaks after each filling of the LP cylinder. Turn the valve clockwise to close.
leaking connection. If the leak persists after several tries, contact BE
Pressure Supply at 1-800-663-8331. The installation of this heater must meet all local codes and/or gas utility requirements. In the absence of local codes, the National Fuel Code ANSI Z223.1 should be followed.
• The minimum clearances to any combustible construction materials must be maintained at all times (See Page 3).
Connecting the Hose to
Heater Inlet
Figure 3: Connecting the Hose / Regulator to the LP Cylinder
© 2012, Pinnacle Products International, Inc.
5
Figure 4: Connecting the Hose to Heater Inlet
Propane Forced Air User’s Manual
16
ventilation
Ventilation
CAUTION
• Always provide a fresh air opening in the heated space of at least three square feet (2,800 sq. cm.) for each 100,000 BTU/hr of heater output.
• a two-car garage door open 6 inches, or
• a single car garage open 9 inches, or
• two thirty two inch wide windows open 15 inches.
17
lighting instructions lighting Instructions
TO START
1. Connect power cord to a properly grounded three (3) prong 120V, 60
Hz, extension cord.
Extension Cord Wire Requirements:
6 to 10 feet (1.8 to 3 meters) long, use 18 AWG conductor.
11 to 100 feet (3.4 to 30.53 meters) long, use 16 AWG conductor.
101 to 200 feet (30.8 to 61 meters) long, use 14 AWG conductor.
2. Connect heater to a proper LP cylinder.
3. Turn gas valve clockwise to OFF position.
4. Wait five (5) minutes for any gas to clear. Smell for gas; if you do not smell gas, go to Step 4.
5. Push in and turn gas control knob counterclockwise to LOW/IGN position. This will light the burner. If needed, keep pressing control knob until the burner lights and keep pressing and turning from OFF to
LOW/ IGN on Piezo electric spark models
6. Keep the valve knob depressed for at least 30 seconds after lighting the burner. After 30 seconds, release valve knob.
7. If burner does not stay lit, repeat lighting procedure.
8. When burner stays lit, turn gas valve knob counterclockwise to desired setting
SHUTDOWN INSTRUCTIONS
To shut off heater:
1. Turn gas valve knob clockwise to OFF position.
2. Turn gas supply OFF by turning LP cylinder valve clockwise to close.
3. Disconnect the power cord.
TEST FIRING THE HEATER
Test fire your construction heater following the lighting instructions applicable to the gas control system employed.
Leak test all gas connections with 50/50 soap and water solution prior to start-up. Soap bubbles indicate a gas leak. DO NOT use a match or flame to test for gas leaks.
NOTE : Heater surface temperature must be cold before initiating service, cleaning or storage.
18
storage/maintenance
Storage/Maintenance
Always disconnect the heater from the LP cylinder before putting the heater into storage. If for any reason the heater is to be stored indoors, the tank MUST be disconnected from the LP cylinder, and the cylinder stored outdoors in a well-ventilated area, out of the reach of children, and in accordance with the Standard for Storage and Handling of Liquefied
Gases, ANSI/NFPA 58 - latest edition and Natural Gas and Propane
Installation Code, CSA 149.1. The plastic valve plug or valve cover supplied with the cylinder must be re-installed on the valve to protect the fitting from damage.
Always be sure to follow proper maintenance procedures. This should include cleaning the inside the heater once a month, and checking the spark gap at least once a heating season.
DANGER
• Never store an LP cylinder inside of a building, or near any other gas or oil burning appliances.
NOTICE
• Installation and repair of this heater should be done by a qualified service person.
19
Wiring Diagrams wiring diagrams
Wiring Diagrams
NEVER LEAVE HEATER UNATTENDED
WHILE BURNING, CONNECTED TO A
POWER SOURCE, OR WHILE
CONNECTED TO A FUEL SOURCE
NEVER LEAVE HEATER UNATTENDED
WHILE BURNING, CONNECTED TO A
POWER SOURCE, OR WHILE
CONNECTED TO A FUEL SOURCE
Figure 5: Wiring Diagram for Piezo/Manual Spark Models
NOTE: If any original wiring as supplied with the heater must be replaced, it must be with type AWG
105°C wire or its equivalent, except as indicated.
NOTE: If any original wiring as supplied with the heater must be replaced, it must be with type AWG
105°C wire or its equivalent, except as indicated.
Figure 6: Wiring Diagram for Continuous Spark Models
© 2012, Pinnacle Products International, Inc.
7
7
NOTE: If any original wiring as supplied with the heater must be replaced, it must be with type AWG
105°C wire or its equivalent, except as indicated.
NOTE: If any original wiring as supplied with the heater must be replaced, it must be with type AWG
105°C wire or its equivalent, except as indicated.
Propane Forced Air User’s Manual
Propane Forced Air User’s Manual
20
parts list
Parts lists
EXPlODED VIEW
2
6
7
8 1
12
10
11
9
26
18
24
3
21
4
27
13
14
15
16 17
22
23
19
20
25
5
28
21
parts lists
PARTS bREAKDOWN
18
19
20
15
16
17
10
11
12
13
14
24
25
26
21
22
23
27
28
7
8
9
4
5
6
REF #
1
2
3
DESCRIPTION
Outer Shell
Inner Shell Assembly
Base
Height Controller
Base Cover
Inner Shell Cap
Multi Bracket Assembly
Thermal Switch
Tubing Assembly
Nozzle
Nozzle Nut
Handle
Flange Hex Nut
Fan
Cushion Pad
Motor Assembly
Guard
Round Bolt
Valve Assembly
Inlet Connector
Spark Module
PCB Assembly
PCB Case
Valve Knob
Power Cord Assembly
Thermal Switch Cable
Hex Nut
Regulator
HL060F
22-524-0021
22-524-0004
22-501-0001
22-512-0005
22-508-0001
22-505-0010
22-504-0002
22-603-0010
22-605-0001
22-081-0014
22-518-0001
22-511-0005
22-518-0003
22-514-0001
22-509-0001
22-061-0015
22-101-0003
22-503-0002
22-011-0017
22-507-0003
22-604-0005
22-521-0002
22-506-0001
22-516-0001
22-131-0001
22-601-0001
22-518-0004
22-041-0004
HL125F
22-524-0022
22-524-0005
22-501-0002
22-512-0008
22-508-0002
22-505-0011
22-504-0003
22-603-0001
22-605-0002
22-081-0015
22-518-0001
22-511-0005
22-518-0003
22-514-0002
22-509-0001
22-061-0016
22-101-0004
22-503-0003
22-011-0018
22-507-0003
22-604-0005
22-521-0002
22-506-0001
22-516-0001
22-131-0001
22-601-0001
22-518-0004
22-041-0005
22
troubleshooting
Troubleshooting
TROUblESHOOTING CHART
Problem
Fan does not turn when electricity is connected
Heater will not fire
(ignite)
Heater stops running by itself
Possible Case Solution
1. No electric power to heater.
2. Blades of fan in contact with heater housing.
3. Fan blades bent.
4. Fan motor defective.
1. No spark at module.
2. Incorrect spark gap.
3. Corroded electrode.
1. Temperature inside heater is too high, causing thermal switch to shut down operation.
2. Damaged control valve.
3. Dust or debris accumulated in heater.
1. Check current at outlet. If voltage is correct, inspect extension and power cords for cuts,frays or breaks.
2. Check housing for damage. Be sure there are no dents in the housing obstructing the fan.
3. Straighten all fan blades.
4. Replace Motor Assembly.
1. Inspect module wire. Re-attach, or tighten if loose. Inspect Spark module, and replace if necessary.
Inspect all other electrical components.
2. Set plug gap to 0.16” (4mm).
3. Replace spark plug (Multi-
Bracket Assembly).
1. If heater input or output is restricted, the inside temperature can become too hot. Keep the areas in front and behind heater clear of obstructions.
2. Replace control valve (Valve
Assembly). 3. Clean inside of heater.
23
warranty
LIMITED WARRANTY
BE Pressure Supply Inc. warrants this heater to the original retail purchaser only, to be free from defects in material and workmanship for a period of one (1) year from the date of initial purchase. This product must be properly installed, maintained and operated in accordance with the instructions provided.
BE Pressure Supply Inc. requires reasonable proof of your date of purchase from an authorized retailer or distributor. Therefore, you should keep your sales slip, invoice, or cancelled check from the original purchase. This Limited Warranty shall be limited to the repair or replacement of parts, which prove defective under normal use and service within the warranty period, and which BE Pressure Supply Inc. shall determine at its reasonable discretion.
This warranty does not apply to products purchased for rental use.
This Limited Warranty does not cover any failures or operating difficulties due to normal wear and tear, accident, abuse, misuse, alteration, misapplication, improper installation or improper maintenance and service by you or any third party. Failure to perform normal and routine maintenance on the heater, shipping damage, damage related to insects, birds, or animals of any kind, and damage due to weather conditions are also not covered. In addition, the
Limited Warranty does not cover damage to the finish, such as scratches, dents, discoloration, rust or other weather damage, after purchase.
All transportation costs for the return of the damaged product or parts will be the responsibility of the purchaser. Upon receipt of damaged item, BE Pressure Supply Inc. will examine the item and determine if defective. BE Pressure Supply Inc. will repair or replace and return the item, freight pre-paid. If BE Pressure Supply Inc. finds the item to be in normal operating condition, or not defective, the item will be returned freight collect. This Limited Warranty is in lieu of all other express warranties. BE Pressure Supply Inc. disclaims all warranties for products that are purchased from sellers other than authorized retailers or distributors.
AFTER THE PERIOD OF THE ONE (1) YEAR EXPRESS
WARRANTY EXPIRES, BE PRESSURE SUPPLY INC. DISCLAIMS
ANY AND ALL IMPLIED WARRANTIES, INCLUDING WITHOUT
LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR APPLICATION. FURTHER, BE
Inc. SHALL HAVE NO LIABILITY WHATSOEVER TO PURCHASER
OR ANY THIRD PARTY FOR ANY SPECIAL, INDIRECT, PUNITIVE,
INCIDENTAL, OR CONSEQUENTIAL DAMAGES.
24
warranty
BE Pressure Supply Inc. assumes no responsibility for any defects caused by third parties. This Limited Warranty gives the purchaser specific legal rights; a purchaser may have other rights depending upon where he or she lives. Some states do not allow the exclusion or limitation of special, incidental or consequential damages, or limitations on how long a warranty lasts, so the above exclusion and limitations may not apply to you.
BE Pressure Supply Inc. does not authorize any person or company to assume for it any other obligation or liability in connection with the sale, installation, use, removal, return, or replacement of its equipment, and no such representations are binding on BE Pressure
Supply Inc.
Always be sure to specify model number and serial number when making any claim with BE Pressure Supply Inc.
For your convenience use the space provided below to list this information:
Model #: _________________________
Serial #: __________________________
Date of Purchase: __________________
25
26
If you need assistance with the assembly or operation of this
Heater please call
1-866-770-1711
Unduh
Iklan