Stand alone wall mounted DMX controller Technical datasheet Touch-sensitive


Add to my manuals
4 Pages

advertisement

Stand alone wall mounted DMX controller Technical datasheet  Touch-sensitive | Manualzz

146 mm

106 mm

SUNSET

Color

R G B

233 076 030

BAR

Stand alone wall mounted DMX controller

Technical datasheet Revision date 30 JULY 2013

Ref. DPAD Gold www.daslight.com

Rechargeable battery

Touch-sensitive user interface

Screw-terminal rear connector

(5 pins)

Extension socket rear connectors

(2x10 pins)

Power+DMX socket

(RJ45)

Ethernet socket

(RJ45)

Front access connections

Page 1/4

Version 1.0

11 mm data led mini usb reset button micro

SD dmx led

Package

Software

Interface, sdcard, datasheet, cdrom, usb cable

DVC3 on PC/Windows

Mobile Apps

Available colors Black frame, various front panel design

Options See the OPTIONS table

Standards

Temperature

DMX Lightpad 3 + ARCOLIS on iPhone/iPad/Android

EC, EMC, ROHS, ETL, UL (some are in process)

-10ºC to 45ºC

Dimensions

Weight

146x106x11 mm Complete package 177x146x48 mm

247 g 8.71 oz Complete package 492 g 17.4 oz

Power Supply

CONNECTION

SPECIFICATIONS

6V DC 0.6A, optional

DMX Output #1 First universe, 512 channels DMX512 output

DMX Output #2 Second universe, 512 channels DMX512 output

USB USB communication for PC/Mac software

Ethernet

Ports 1,2,...,8

User interface

Advanced networking features

8 Contact closure inputs, connect to ground for operating

10 buttons, 1 wheel, 1 color display, 5 leds

(Touch-sensitive keypad)

Micro sd card for stand alone memory use (supplied) SD card

RESET

RS232

Output relay

Clock

Push button for feet operation

RS232 serial communication for external synchronisation

Automatic standby 5V signal

Real-time clock and calendar

Built-in features

Screw-terminal rear connector

(5 pins)

Extension socket rear connectors

(2x10 pins)

Power+DMX socket

(RJ45)

Ethernet socket

(RJ45)

Front access connections

USB

• power/data leds

RJ2BLOCK

POWER4M

VERSIONS

OPTIONS / ACCESSORIES

RJ45 to connector block converter for POWER+DMX

Dedicated power adapter 110-220V to 6VDC

WHITE, choices of wheel design

© Daslight 1989-2012. All rights reserved. We reserve the right without notice to amend the technical information and specifications.

Stand alone wall mounted DMX controller

Technical datasheet Revision date 30 JULY 2013

Ref. DPAD Gold www.daslight.com

Page 2/4

Version 1.0

EASY INSTALLATION

1. Mount an electrical box inside the wall

The S.T.I.C.K. controller can be installed in any standard electrical backbox. If you use a double size box, you can insert the power supply inside.

2. Connect the wires

POWER: Connect a 5.5V or 6V DC 0.6A.

Be sure to not invert the + and the ground.

DMX: Connect the DMX cable to the lighting receivers (Leds, Dimmers, Fixtures..)

(for XLR: 1=ground 2=dmx- 3=dmx+)

3. Mount the interface on the wall

First, mount the back side of the interface on the wall with 2 or more screws

Secondly, plug the connectors :

- Ethernet cable

- DMX and power (connector block or RJ45)

POWER+DMX

WITH THE

CONNECTOR BLOCK

DC +

POWER

Ground

Ground

DMX -

DMX +

POWER+DMX

WITH THE

RJ45 CABLE

© Daslight 1989-2012. All rights reserved. We reserve the right without notice to amend the technical information and specifications.

1 DMX +

2 DMX -

(

3 DMX2 +

4 POWER

5 DC +

6 DMX2 -

(

7 POWER

8 GROUND

1.......8

POWER

+DMX

Stand alone wall mounted DMX controller

Technical datasheet Revision date 30 JULY 2013

Ref. DPAD Gold www.daslight.com

Page 3/4

Version 1.0

2x10 pins EXTENSION connector

DMX CHIPS can be

replaced here

DMX

universe #1

DMX

universe #2

VIN

GND

IR_RX

3.3V

Relay

DMX2+

DMX2-

DMX1+

DMX1-

GND_DMX

4

2

8

6

12

10

20

18

16

14

11

9

7

5

19

17

15

13

3

1

PORT1

PORT2

PORT3

PORT4

PORT5

PORT6

PORT7

PORT8

RS232 RX

RS232 TX

Ref: SP485ECN-L

MAX485 CSA

BLACKOUT relay

(energy saving)

using the 2 pins : BK and G (GND)

Example of relay : FINDER

Ref. 22.23.9.012.4000

http://www.findernet.com/fr/products/ profiles.php?serie=22&lang=en

RS232 triggering

Make a cable using the 3 pins : TX, RX and G (GND)

Set the RS232 parameters to : 9600bds 8 bits, no Parity, 2 Stop bits

(x = scene number)

- To play a scene, send 3 bytes :

- To stop a scene, send 3 bytes :

- To pause a scene, send 3 bytes :

- To release a pause, send 3 bytes :

- To reset a scene, send 3 bytes : means Page B Scene #3

1 x 255

2 x 255

3 x 255

4 x 255

5 x 255

Note: the scene number (x) can be from 1 to 40. For instance, 11

Button

<

Compatible connectors:

WURTH ELEKTRONIK ref: 61301021121

MOLEX ref: 10-89-7202

TE Connectivity ref: 1-87227-0

FCI ref: 77313-101-20LF

HARWIN ref: M20-9981046

SAMTEC ref: TSW-110-xx-T-D

FARNELL ref: 1841232

RS ref: 763-6754 673-7534 251-8165

MOUSER ref: 538-10-89-7202

DIGIKEY ref: WM26820-ND

PORT triggering

It is possible to start scenes using the input ports (contact closure). To activate a port, a brief contact must be established between the ports

(1...8) and the ground (GND). This is a contact closure so there is no need to hold the connection, it acts like a basic switch.

P1 P2 P3 P4 ... GND

INTERNAL MENU (hardware configuration)

Button

>

ZONEZONE+

To access the settings menu, hold the on/off button for 3 seconds.

Mode (M): Manages the on/off button and the 4 modes (dimmer, speed, color, scene)

M OFF enable: enables/disables the use of the on/off button so that the controller is permanently on

M Dimm. enable: when enabled, scenes can be made brighter or darker

M Color. enable: when enabled, the color of a scene can be changed

M Speed. enable: when enabled, dynamic scenes can be made faster and slower

M Scene. enable: when enabled, the scene can be changed

M Auto mode: when enabled, the controller will revert to the default mode after it has been left for a specified period of time

M Auto time: the amount of time the controller will wait before reverting to the default mode

M Default: the default mode which the controller will revert to after a certain amount of time

M Dimmer 100%: when enabled, the dimmer mode will adjust between 0% and 100% without saturating to white between 100% and 200%

Arrows (A): Allows you to adjust which modes can be controlled by the arrows

A Dimmer enable: allows for the Dimmer mode to be controlled by the arrows

A Color enable: allows for the Color mode to be controlled by the arrows

A Speed enable: allows for the Speed mode to be controlled by the arrows

A Scene enable: allows for the Scene mode to be controlled by the arrows

© Daslight 1989-2012. All rights reserved. We reserve the right without notice to amend the technical information and specifications.

Stand alone wall mounted DMX controller

Technical datasheet Revision date 30 JULY 2013

Ref. DPAD Gold www.daslight.com

Page 4/4

Version 1.0

Pallet (P): Allows you to adjust which modes can be controlled by the palette wheel

P Dimmer enable: allows for the Dimmer mode to be controlled by the palette wheel

P Color enable: allows for the Color mode to be controlled by the palette wheel

P Speed enable: allows for the Speed mode to be controlled by the palette wheel

P Scene enable: allows for the Scene mode to be controlled by the palette wheel

Scene (S): Scene management

S 0(off) enable: displays an empty off scene before scene 0 in each area

S Pause enable: allows a scene to be paused if the scene mode button is held for 1 second

S Stop enable: allows a scene to be stopped if the scene mode button is held for 4 seconds

S Fade enable: forces a fade time between each scene

S Fade time: the time of the automatic fade between scenes

S Auto reset: when enabled, any color, dimmer or speed overrides will be reset each time the scene is changed

S Trigger delay: adds a short delay each time a new scene is triggered, allowing scenes to be scrolled through without triggering

First Start (F): Default settings when the unit is first powered up

F Scene Nr.: specify a default scene number

F Display Time: when enabled, the time will be displayed on the screen at startup

F Scene Nr.: enables the triggering of a scene at startup. If disabled, no scene will be triggered

Trigger (T): Manages the controllers external triggering properties

T Time enable: enables the clock triggering

T Ports enable: enables the 8 dry contact ports

T RS232 enable: enables scene triggering by RS232

T IR enable: enables the infra red port (disabled by default to prevent interference)

T UDP enable: allows the controller to send and receive UDP messages required for network control

Ethernet (E): Manages the controllers network settings

Ethernet: Enables the Ethernet socket on the controller

Dynamic IP Addr: enables dynamic IP addressing (DHCP) which allows the controller to obtain an IP address from a router

Device’s IP Add: the controllers static IP address it will use if it does not receive an IP address via DHCP

Date/Time (D): Manages the date and time stored inside the controller

Date: the controllers date

Time: the controllers clock time

Graphics (G): Screen management

G Image enable: allows for images to be shown for each scene if they have been assigned in the programming software

G Image full: when enabled, the image will be displayed in full screen and the scene and area will not be visible

G Image time: the time it takes before the image is displayed in full screen

G Sleep enable: when enabled, the screen brightness will dim after a certain amount of time

G Sleep time: the amount of time to wait before sleeping

G Bright normal: the % brightness when the controller is not sleeping

G Bright sleep: the % brightness when the controller is sleeping

G Bright LED: the % brightness of the mode and reset LEDs

DMX Output (X): Manage the timings of the DMX output messages and the page priorities (advanced function!)

X MBB: Mark Before Break- the time to wait between sending each 512 channel DMX message (or ‘packet’)

X Break: Break- the time to wait just before sending a new packet, resetting the DMX line

X MAB: Mark After Break- the message which tells your receiver to begin reading data

X MBS: Mark Between Slots- the delay time between sending each DMX channels data within the DMX packet

Univ-1/Univ-2: each timing can be set differently depending on the universe number

X Alphab Mode: if the same scene is triggered in the global area and a second area, the area with the highest letter will take priority

X LTP Mode: f the same scene is triggered in the global area and a second area, the latest scene triggered takes priority

Sensitive (S): Manage the touch sensitivity settings

S USB Init: reset the touch sensitivity when the USB is connected and disconnected

S Auto Init: automatically reset the touch sensitivity after a period of time

S Auto Time: the time to wait before automatically resetting the touch sensitivity

S High Sense: when enabled, the sensitivity will be increased

S See Values: see each touch sensitive button number and palette value

Language (L): change the language of the text which appears on the screen

About: check the firmware release date and version number and assign a name for the controller

Reset: reset all settings to the factory default

SOFTWARE and LINKS

ARCOLIS sofware (Touch Lighting Editor app for iPhone/iPad, Android)

DMX Lightpad 3 (Remote application for iPhone/iPad, Android)

=>download your application from Google Play or the App Store

ESA, ESAPRO software (Windows)

ESA2 software (Windows, Mac) manuals www.nicolaudie.com (-> Support -> Downloads) www.nicolaudie.com (-> Support -> Downloads)

www.nicolaudie.com/manuals.php

© Daslight 1989-2012. All rights reserved. We reserve the right without notice to amend the technical information and specifications.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals