V-Tec VT596F/KP User manual
Add to my manuals
12 Pages
The V-Tec VT596/KP is a 4-wire video intercom system that allows for communication between multiple indoor and outdoor stations, providing enhanced security and convenience for your property. With its digital keypad and touch-sensitive buttons, you can easily control various functions, including door unlocking, volume adjustment, and camera angle adjustment. The device features a rainy cover for outdoor installation, ensuring reliable operation even in adverse weather conditions. Additionally, the VT596/KP supports electronic lock connection, enabling remote door unlocking and monitoring.
advertisement
VT596(F)/KP USER MANUAL(EN)
4 Wire Video Intercom System
VT596/KP VT596F/KP
Read this manual carefully before using the product, and keep it well for future use.
-1-
1. Parts and Functions
1 2 3
4 5 6
7
*
8 9
0 #
Camera Lens
Speaker
Indicator(red)
Indicator(blue)
Touch Sensitive
Digital Keypad
Nameplate
Call Button
Microphone
VT596/KP
1 2 3
4 5 6
7
*
8 9
0 #
VT596F/KP
Camera Lens
Speaker
Indicator(red)
Indicator(blue)
Touch Sensitive
Digital Keypad
Nameplate
Call Button
Screws for panel mounting
Microphone
1 2 3
4 5 6
7
*
8 9
0 #
90 mm
2. Terminal Descriptions
1 2 3
4 5 6
7
*
8 9
0 #
119 mm
28 mm
Side View
Rainy Cover
Mounting box
MIC adjustment
SPK adjustment
JP/LK
Lock Control Jumper
RS485 Connect Port
DIP Switches
Main Connect Port
•• JP/LK(Lock Control Jumper): To•select•the•lock•type:•see•section•4(lock•connect)
•• DIP Switches: Reserve.
•• RS485: Used•to•update•the•program
•• MIC :•Adjust•the•volume•of•Microphone
•• SPK :•Adjust•the•volume•of•Speaker
•• Main Connect Port: •To•connect•the•bus•line•and•the•electronic•locks.
•• DC+,DC-:•Power•supply•connection•port,16~24V,•polarity.
•• 1R:•Power•positive.•+12V•present•when•outdoor•station•calling•or•being•monitored.
•• 2W:•Power•negative•(GND)
•• 3Y:•Image•signal•(Video•signal)
•• 4B:•Talk•and•control•signal•(Audio•signal)
•• PL:•External•lock•power•input,•connect•to•the•power•positive(power•+).
•• S+:•Lock•power(+)•output.
•• S-:•Lock•power(-)•output.
3. Door Station Mounting
VT596/KP Mounting
1 2 adjust camera angle
4 core cable
PS
Drill holes in the wall to match the size of screws and attach the rainy cover to the wall.
3 4
Connect the cable correctly and adjust right angle for camera
-2-
Attach the panel to the rainy cover Use the screwdriver and the screw to fix the panel
-3-
VT596F/KP Mounting
1
90mm
52mm
4 core cable
PS
2 adjust camera angle
Drill a hole in the wall to match the size of the mounting box and attach to the wall.
3 4
Connect the cable correctly and adjust right angle for camera
Attach the panel to the mounting box and use screws supplied to fix the panel
Placing Name Label
Place name label
1 2 3
4 5 6
7
*
8 9
0 #
Press•the•plastic•cover•on•right/left•side• to•move•away•the•cover,•insert•a•name• paper,•then•put•the•plastic•cover•back•to• the•panel.•
-4-
4. System Wiring and Electric Lock Connection
Basic Connection
AC ~
*
1 2 3
4 5 6
7 8 9
0 #
TO Monitor
JS/OS1
3Y 4B
Shielding Layer of the RVVP Cable
3Y 4B
Electric Lock Connection
•• Mode1:Door•Lock•Controlled•With•Dry•Contact
Must•install•external•power•supply•for•lock,and•nearly•all•kinds•of•electronic•lock•can•be•used.Incidentally,in• this•mode,you•can•continue•talking•and•monitoring•during•unlock•operation.
AC ~
VT596(F)
POWER
SUPPLY
+
-
Black Red
Connect to Monitor
+
-
LOCK
Take off JP/LK Jumper
Note:•
1.The•external•power•supply•must•be•used•according• to•the•lock.
2.The•inside•relay•contact•is•restricted•to•AC•or•DC•
24V/1A.
3.The•jumper•must•be•taken•off•before•connecting.
4.Setup•the•Unlock•Mode•on•door•station•for•different• lock•types.
•• Power-on-to-unlock•type:Unlock•Mode=0•
•• Power-off-to-unlock•type:Unlock•Mode=1
-5-
•• Mode2:Door•Lock•Controlled•With•Internal•Power
The•lock•can•be•directly•connected•with•the•door•station•and•the•power•through•monitor.During•unlock• operation,the•monitor•will•close•screen•automatically.
AC ~
VT596(F)
Connect to Monitor
1 2 3
JP/LK Jumper position in 2-3
Unlock mode:0
-
+
LOCK
Note:
1.Electronic•lock•of•power-on-to-unlock•shoule•be• used.
2.The•door•lock•is•limited•to•12V,and•holding•current• must•be•less•than•250mA
3.The•door•lock•control•is•not•timed•from•Exit•
Button(EB).
4.•The•Unlock•Mode•Parameter•of•Monitor•must•be• set•to•0•(by•default).
5. Functions Setting Up
This•section•explains•the•settings•of•each•function,please•refer•to•the•following•table:
About•the•setting•mode:
Input•the•master•code•to•switch•to•the•setting•mode,•and•input•the•corresponding•setting•code•to•perform• the•settings•for•the•function•you•want.•After•settings•have•been•made,•input•the•following•setting•codes•to• continue•the•setting•operation.•Press•"• •"•to•exit•the•setting•mode.
•• The•example•is•set• •as•cancel•button•and•#•as•confirm•button,please•refer•to•
*/#•function•setting•for•detail•information.
•• Forbid•to•slide•to•touch•the•digital•keypad,it•may•cause•mistaken•key,the• correct•operation•is•using•your•finger•to•press••the•digital•you•desired.
•• You•should•press“confirm”button•after•finish•inputting•the•code•number•each• time,otherwise,the•operation•will•be•canceled•automatically•in•10s.
-6-
5
8
9
6
7
3
4
10
11
12
13
Order
1
2
14
Setting items Setting range
Reset•all•settings 1234
Setting•the•master•code
Setting•the•key illumination•time
1•~•12•digits
Valid•keys:0•~•9
10•to•99•seconds/ continually•lit(00s)
Setting•the•unlock•time 01•to•99•seconds
Setting•the•unlock• mode
Operation•tone•settings
•0:opened/1:closed
0:on/1:off
Reset•code•settings 1234
&#•function•settings 0:Normal/1:Reverse
Reserve
Interference•resistant•• grade•settings
Reserve
Setting•the•code• forTemporary1
Setting•the•code• forTemporary2•
Setting•the•code•for• user
Reserve
Valid•keys:0•~•5
Reserve
1•~•12•digits
Valid•keys:0~9
1•~•12•digits
Valid•keys:0~9
1•~•12•digits
Number•of•codes:80
Valid•keys:0~9
Default value Setting code
00
1234 01
10•seconds
1•seconds opened on
-
Normal
Reserve
2
Reserve
-
-
04
07
08
05
06
02
03
09
10~17
18
19
20~99
About Functions Setting steps
red blue
1 2 3
4 5 6
7
*
8 9
0 #
Each•operation•is•indicated•by•the•lighting•up•of•the•LED• indicators•on•the•right•section•of•the•unit,•and•by•the• sounding•of•the•buzzer.
-7-
Setting items
1.Reset all settings
Step 1
Input the master code.
(Default: [ ] +[#] )
2.Setting the master code
(Default 1234)
Step 1
3.Setting the key
illumination time
(Default 10s)
Step 1
(red)
ON
(blue)
OFF
4.Setting the
unlock time
(Default 1s)
Step 1
Beep+, Beep
Step 2
Input the setting code.
00+#
Step 2
Input the setting code.
01+#
Step 2
Input the setting code.
02+#
Step 2
Input the setting code.
03+#
(red)
ON
(blue)
ON
Beep+, Beep
(red)
ON
(blue)
ON
Beep+, Beep
(red)
ON
(blue)
ON
Beep+, Beep
(red)
ON
(blue)
ON
Beep+, Beep
Step 3
Inputting of code
(red)
ON
1234+#
(blue)
OFF
Beep+
Step 3
Inputting of new master code
(ex.: 4321)(1~12 digits)
4321+#
(red)
ON
(blue)
OFF
Beep+
Step 3
Inputting of code (ex.: 10) range:00 or 10~99
10+#
(red)
ON
(blue)
OFF
Beep+
Step 3
Inputting of code (ex.: 09) range:01~99
09+#
(red)
ON
(blue)
OFF
Beep+
- When there isn’t any operation in 10s, the LED lights off, the buzzer beeps, and the system exits the setting mode
(red)
OFF
(blue)
OFF
Beep, Beep+
- All settings will restore to their default value.
- When power on or activate the reset all setting item,the keypad checking will carry out, during this time,the key illumination will blink and the touching operation is forbidden, after finish checking,the key illumination will stop blinking and sent out a long sound of beep
- The master code is allowed 1~12 digits,the same code cannot be set for both the user code and the master code,it is recommended that you modify the default master code.
- If the key illumination time is set to 00,the key illumination will light up all the time when power on.
- If the key illumination time is set to
10~99,the key illumination will light up for 10~99 seconds.At this mode, the key illumination lights off in standby mode, touching any digital key can illuminate,but this is the invalid digital.
- The unlock time is the time that use keypad access to unlock.
-8-
Setting items
5.Setting the unlock mode
(Default 0(opened))
6.Setting operation tone
(Default ON)
7.Reset code setting
(Default Normal)
Step 1
Input the master code.
(Default: [ ] +[#])
Step 2
Input the setting code.
04+#
(red)
ON
(blue)
ON
Beep+, Beep
Step 1
Step 2
Input the setting code.
05+#
(red)
ON
(blue)
ON
Beep+, Beep
Step 1
(red)
ON
(blue)
OFF
Step 1
Beep+, Beep
Step 2
Input the setting code.
06+#
Step 2
Input the setting code.
07+#
(red)
ON
(blue)
ON
Beep+, Beep
(red)
ON
(blue)
ON
Beep+, Beep
Step 3
Inputting of code
(ex.: 1) range:0:(open)/1:(close)
1+#
0/1
(red)
ON
(blue)
OFF
Beep+
Step 3 0/1
Inputting of code range:0:(on)/1:(off)
(ex.: 1)
1+#
(red)
ON
(blue)
OFF
Beep+
Step 3
Inputting of code
1234+#
(red)
ON
Beep+
Step 3 0/1
Inputting of code
(ex.: 1) range:0:(normal)/1:(reverse)
1+#
(red)
ON
(blue)
OFF
Beep+
- When there isn’t any operation in 10s, the LED lights off, the buzzer beeps, and the system exits the setting mode
(red)
OFF
(blue)
OFF
Beep, Beep+
- The unlock mode is used to match the type of lock,If it’s set to 0,unlock mode is power-on-to unlock,and must use electric lock.
If it’s set to 1,unlock mode is power-off-to-unlock,and must use electromagnetic lock.
- When the operation tone is set to 0,pressing the digital keypad will sent out a sound of beep.
- When the operation tone is set to 1,pressing the digital keypad will blink one time.
- Cancel all the passwords except the master code.
- Restore the master code to default value(1,2,3,4)
- When the item is set to 0,press
* the input.
- When the item is set to 1,press the # button to cancel the input, and press the button to confirm the input .
*
-9-
Setting items
10.Interference resistant
grade setting
(Default 2)
12.Setting the code
forTemporary1
Step 1
Input the master code.
(Default: [ ]+[#] )
Step 1
13.Setting the code
forTemporary2
Step 1
(red)
ON
(blue)
OFF
14.Setting the code
for user
Step 1
Beep+, Beep
Step 2
Input the setting code.
09+#
(blue)
ON
Beep+, Beep
Step 2
Input the setting code.
(red)
ON
18+#
Beep+, Beep
Step 2
Input the setting code.
(red)
ON
19+#
Beep+, Beep
Step 2 20~99
Input the setting code.
(ex.:21)
21+#
(red)
ON
Beep+, Beep
Step 3
Inputting of code (ex.: 3) range:0~5
3+#
(blue)
OFF
Beep+
Step 3
Inputting of code (ex.: 1006)
1~12 digits
1006+#
(red)
ON
(blue)
OFF
Beep+
Step 3
Inputting of code (ex.: 2011)
1~12 digits
2011+#
(red)
ON
(blue)
OFF
Beep+
Step 3
Inputting of code (ex.: 2011)
1~12 digits
2011+#
(red)
ON
(blue)
OFF
Beep+
- When there isn’t any operation in 10s, the LED lights off, the buzzer beeps, and the system exits the setting mode
(red)
OFF
(blue)
OFF
Beep, Beep+
- The larger you set the interference resistant grade,the stronger it will be, but the sensitivity of the keypad will be more lower.
- The interference resistant grade setting also will activatethe keypad checking.
- When input the correct temporary password to release the door, the system will clear the temporary password after 60 seconds automatically.But you should know that the password is valid within
60 seconds after inputing the correct temporary password
- If the password length exceeds 12 digits, the system will sent out the sound of “beep,beep,beep,beep”,and the digitals you input before will be cleared at the same time.
- The temporary code can not be set the same as the master code and user code.
- The user code is used to release the lock,80 group passwords can be supported.
- If the password length exceeds
12 digits, the system will sent out the sound of “beep,beep,beep,beep”, and the digitals you input before will be cleared at the same time.
- The user code can not be set the same as the master code and temporary code.
-10-
6. Unlock Operations
Unlocking of user code
When•the•registered•user•code•has•been•input•using•the•keypad•(1~12•digits),•the•LED•indicator•(red)•lights• up,•the•buzzer•sounds,and•the•electric•door•strike•is•unlocked.(note•that•you•should•press•"#"•button(if•"#"• button•is•set•to•confirm•button)•after•input•the•unlock•code)
Example:•
Unlock code=2011
Red LED lights up
(during relay1 operation)
(red)
ON
(blue)
OFF
Beep+
•• The•time•interval•during•which•the•button•must•be•pressed•is•approximately•10•seconds.•If• the•time•interval•exceeds•approximately•10•seconds,•the•input•value•will•be•cleared.
•• If•you•make•a•mistake•when•inputting•the•user•code,press•the"•cancel"•button•and•input•the• user•code•again.
•• If•10•times•incorrect•access•codes•are•continuously•attempted,•the•release•function•is• forbidden•and•the•input•operation•is•disabled•for•60•seconds•.•During•this•time,the•buzzer•will• continuously•sound•about•8•times.
•• You•can•activate•the•electric•door•strike•by•pressing•the•request•to•exit•button•connected•to• the•unit.•(The•unlock•function•will•work•when•the•request•to•exit•button•is•pushed,•even•while• the•keypad•operating•is•forbidden.)
1.•During•calling,pressing•"cancel"•button•can•cancel•the•calling
2.•If•input•the•incorrect•access•code,the•buzzer•will•sound•of•beep,beep,beep
-11-
7. Precaustions
•• Please•clean•the•unit•with•soft•cotton•cloth,•don't•use•the•organic•impregnant•or•chemical• clean•agent.•If•necessary,•please•use•a•little•pure•water•or•dilute•soap•water•to•clean•the•dust.
•• The•unit•is•weather•resistant.•However•do•not•spray•high•pressure•water•on•access•control• keypad•directly.•Excessive•moisture•may•cause•problems•with•the•unit.
•• You•must•use•the•right•adaptor•which•is•supplied•by•the•manufacture•or•approved•by•the• manufacture..
•• Pay•attention•to•the•high•voltage•inside•the•products,•please•refer•service•only•to•a•trained• and•qualified•professional.
8. Specifications
•• Power•Supply•:•••
•• Power•Consumption:•• •
•• Camera:••
•• Unlocking•time:••
•
•• Lock•Power•supply:•• •
•• Mounting:• •
•
•
•
•
• 12Vdc,•300mA(Internal•Power);
••••••••••••••••Surface•mounting(DT596/KP)••••••••••••••••••••••••••••••••••
•••••••••••••••••••••••••••••••••••••••••••••••••Flush•mounting•(DT596F/KP)•••••••••••••••
•• Working•temperature:• •
•• Dimension:• • •
•
•
•
•
•
•
DC•16~20V•
Standby•0.5W;•Working•status•3W;
Pinhole•Sharp•Color•CCD;
1~99s
•-10ºC•~•+45ºC
176(H)×90(W)×28(D)mm(DT596/KP)
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••220(H)×119(W)×52(D)mm(DT596F/KP)
The•design•and•specifications•can•be•modified•without•notice•to•the•user.•Right•to•interpret•and•copyright•of•this•manual•are•preserved.
Printed•In•China•/•2011.•09
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Key Features
- 4-wire video intercom system
- Digital keypad for easy access
- Built-in camera for video monitoring
- Connects to electric locks for remote access
- Adjustable volume for microphone and speaker
- Rainy cover for outdoor use