- Home
- Domestic appliances
- Climate control
- Split-system air conditioners
- Mitsubishi
- City Multi PKFY-P.VBM-E
- User manual
Mitsubishi | City Multi PKFY-P.VBM-E | User manual | Wall mounted PKFY-P-VBM-E, VHM-E, VKM-E
Add to my manuals
14 Pages
Mitsubishi City Multi PKFY-P.VBM-E is a wall-mounted indoor unit designed for efficient and comfortable climate control in residential and commercial spaces. With its advanced features and capabilities, it offers a range of benefits to enhance your indoor environment:
-
Flexible Cooling and Heating: The unit provides both cooling and heating functionality, allowing you to maintain a comfortable temperature all year round.
-
Energy Efficiency: Equipped with energy-saving technology, the PKFY-P.VBM-E operates efficiently, reducing energy consumption and lowering your utility bills.
-
Quiet Operation: Designed for quiet operation, the unit minimizes noise levels, ensuring a peaceful indoor environment, even while in operation.
advertisement
Wall mounted DATA G8 PKFY-P-VBM-E, VHM-E, VKM-E I.Wall mounted 1. SPECIFICATIONS........................................................................................................................................... 1 - 150 2. EXTERNAL DIMENSIONS .............................................................................................................................. 1 - 152 3. CENTER OF GRAVITY ................................................................................................................................... 1 - 155 4. ELECTRICAL WIRING DIAGRAMS ................................................................................................................ 1 - 156 5. SOUND LEVELS ............................................................................................................................................. 1 - 159 5-1. Sound levels ............................................................................................................................................ 1 - 159 5-2. NC curves ................................................................................................................................................ 1 - 159 6. TEMPERATURE/AIRFLOW DISTRIBUTIONS ............................................................................................... 1 - 160 6-1. Temperature distributions ........................................................................................................................ 1 - 160 6-2. Airflow distributions .................................................................................................................................. 1 - 161 7. OPTIONAL PARTS.......................................................................................................................................... 1 - 162 7-1. Optional parts line up for the Indoor unit.................................................................................................. 1 - 162 7-2. External LEV Box..................................................................................................................................... 1 - 162 7-3. Drain pump .............................................................................................................................................. 1 - 162 INDOOR UNITS 1 - 149 1. SPECIFICATIONS DATA G8 I.Wall 1. SPECIFICATIONS mounted Model PKFY-P15VBM-E PKFY-P25VBM-E PKFY-P32VHM-E Cooling capacity *1 kW 1.7 2.2 2.8 3.6 (Nominal) *1 kcal / h 1,450 1,900 2,400 3,100 *1 BTU / h 5,800 7,500 9,600 12,300 *2 kcal / h 1,500 2,000 2,500 3,150 Power input *4 kW 0.04 0.04 0.04 0.04 Current input *4 A 0.20 0.20 0.20 0.40 Heating capacity *3 kW 1.9 2.5 3.2 4.0 (Nominal) *3 kcal / h 1,600 2,200 2,800 3,400 13,600 (220V) (220V) *3 BTU / h 6,500 8,500 10,900 Power input kW 0.04 0.04 0.04 0.03 Current input A 0.20 0.20 0.20 0.30 Plastic, MUNSELL (1.0Y 9.2/ Plastic, MUNSELL (1.0Y 9.2/ Plastic, MUNSELL (1.0Y 9.2/ Plastic, MUNSELL (1.0Y 9.2/ 0.2) 0.2) 0.2) 0.2) External finish External dimension HxWxD mm in. Net weight 295x815x225 295x815x225 295x815x225 295x898x249 11-5/8 x 32-1/8 x 8-7/8 11-5/8 x 32-1/8 x 8-7/8 11-5/8 x 32-1/8 x 8-7/8 11-5/8 x 35-3/8 x 9-13/16 kg(lbs) Heat exchanger FAN 10 (23) 10 (23) 10 (23) 13(29) Cross fin (Aluminum fin and copper tube) Cross fin (Aluminum fin and copper tube) Cross fin (Aluminum fin and copper tube) Cross fin (Aluminum fin and copper tube) Line flow fan x 1 Type x Quantity External static press. Line flow fan x 1 Line flow fan x 1 Line flow fan x 1 Pa 0 0 0 0 mmH2O 0 0 0 0 1-phase induction motor 1-phase induction motor 1-phase induction motor DC motor 0.017 0.017 0.017 0.030 Direct-driven by motor Direct-driven by motor Direct-driven by motor Direct-drive Motor Type Motor output kW Driving mechanism Airflow rate m3 / min 4.9-5.0-5.2-5.3 4.9-5.2-5.6-5.9 4.9-5.2-5.6-5.9 9-10-11 (Low-Mid2-Mid-High) L/s 82-83-87-88 82-87-93-98 82-87-93-98 150-167-183 cfm 173-177-184-187 173-184-198-208 173-184-198-208 318-353-388 29-31-32-33 29-31-34-36 29-31-34-36 34-37-41 Polyethylene sheet Polyethylene sheet Polyethylene sheet Polyethylene sheet Sound pressure level (measured in anechoic room) dB <A> Insulation material Air filter PP honeycomb PP honeycomb PP honeycomb PP honeycomb Protection device Fuse Fuse Fuse Fuse Refrigerant control device LEV LEV LEV LEV Connectable outdoor unit PURY-P-Y(S)JM-A PUHY-P-Y(S)JM-A PUMY-P100~140VHMB PUMY-P100~140YHMB PQRY-P-Y(S)HM-A PQHY-P-Y(S)HM-A R410A CITY MULTI R410A CITY MULTI R410A CITY MULTI Diameter of refrigerant pipe PKFY PKFY-P20VBM-E 1-phase 220-240V 50Hz, 1- 1-phase 220-240V 50Hz, 1- 1-phase 220-240V 50Hz, 1- 1-phase 220-240V 50Hz, 1phase 220V 60Hz phase 220V 60Hz phase 220V 60Hz phase 220V 60Hz Power source Liquid (R410A) mm(in.) 6.35(1/4) Flare 6.35(1/4) Flare 6.35(1/4) Flare 6.35(1/4) Flare Gas (R410A) mm(in.) 12.70(1/2) Flare 12.70(1/2) Flare 12.70(1/2) Flare 12.70(1/2) Flare mm(in.) Field drain pipe size Drawing I.D. 16(5/8) I.D. 16(5/8) I.D. 16(5/8) I.D. 16(5/8) External - - - - Wiring - - - - Refrigerant cycle - - - - Installation Manual, Instruction Book Installation Manual, Instruction Book Installation Manual, Instruction Book Installation Manual, Instruction Book - Standard attachment Document Optional parts External LEV Box Accessory Drain pump Remarks Notes : - - - PAC-SG95LE-E PAC-SG95LE-E PAC-SG95LE-E - - - - PAC-SH75DM-E * Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual. * Due to continuing improvement, above specification may be subject to change without notice. *1 Nominal cooling conditions (subject to JIS B8615-1) Indoor : 27degC D.B. / 19degC W.B. (81degF D.B. / 66degF W.B.) Outdoor : 35degC D.B. (95degF D.B.) Pipe length : 7.5 m (24-9/16 ft.) Level difference : 0 m (0 ft.) *2 Nominal cooling conditions *3 Nominal heating conditions (subject to JIS B8615-1) 27degC D.B. / 19.5degC W.B. 20degC D.B. kcal/h = kW x 860 (81degF D.B. / 67degF W.B.) (68degF D.B.) BTU/h = kW x 3,412 35degC D.B. 7degC D.B. / 6degC W.B. cfm = m3/min x 35.31 (95degF D.B.) (45degF D.B. / 43degF W.B.) lbs = kg / 0.4536 5 m (16-3/8 ft.) 7.5 m (24-9/16 ft.) 0 m (0 ft.) 0 m (0 ft.) Unit converter *The specification data is subject to rounding variation. *4 Electrical characteristic of cooling are included optional drain-pump. (Applicable only to PKFY-P32VHM-E) INDOOR UNITS 1 - 150 1. SPECIFICATIONS DATA G8 Model PKFY-P40VHM-E PKFY-P50VHM-E PKFY-P63VKM-E PKFY-P100VKM-E 1-phase 220-240V 50Hz, 1- 1-phase 220-240V 50Hz, 1- 1-phase 220-240V 50Hz, 1- 1-phase 220-240V 50Hz, 1phase 220V 60Hz phase 220V 60Hz phase 220V 60Hz phase 220V 60Hz Power source Cooling capacity *1 kW 4.5 5.6 7.1 11.2 (Nominal) *1 kcal / h 3,900 4,800 6,100 9,600 (220V) *1 BTU / h 15,400 19,100 24,200 38,200 *2 kcal / h 4,000 5,000 6,300 10,000 Power input *4 kW 0.04 0.04 0.05 0.08 Current input *4 A 0.40 0.40 0.37 0.58 Heating capacity *3 kW 5.0 6.3 8.0 12.5 (Nominal) *3 kcal / h 4,300 5,400 6,900 10,800 42,600 (220V) *3 BTU / h 17,100 21,500 27,300 Power input kW 0.03 0.03 0.04 0.07 Current input A 0.30 0.30 0.30 0.51 Plastic, MUNSELL (1.0Y 9.2/ Plastic, MUNSELL (1.0Y 9.2/ Plastic, MUNSELL (1.0Y 9.2/ Plastic, MUNSELL (1.0Y 9.2/ 0.2) 0.2) 0.2) 0.2) External finish External dimension HxWxD Net weight mm 295x898x249 295x898x249 365x1170x295 365x1170x295 in. 11-5/8 x 35-3/8 x 9-13/16 11-5/8 x 35-3/8 x 9-13/16 14-3/8 x 46-1/16 x 11-5/8 14-3/8 x 46-1/16 x 11-5/8 kg(lbs) Heat exchanger FAN 13(29) 13(29) 21(46) 21(46) Cross fin (Aluminum fin and copper tube) Cross fin (Aluminum fin and copper tube) Cross fin (Aluminum fin and copper tube) Cross fin (Aluminum fin and copper tube) Line flow fan x 1 Type x Quantity External static press. Line flow fan x 1 Line flow fan x 1 Line flow fan x 1 Pa 0 0 0 0 mmH2O 0 0 0 0 DC motor DC motor DC motor DC motor 0.030 0.030 0.056 0.056 Direct-drive Direct-drive Direct-drive Direct-drive Motor Type Motor output kW Driving mechanism Airflow rate m3 / min 9-10.5-11.5 9-10.5-12 16-20 20-26 (Low-Mid-High) L/s 150-175-192 150-175-200 267-333 333-433 cfm 318-371-406 318-371-424 565-706 706-918 34-38-41 34-39-43 39-45 41-49 Polyethylene sheet Polyethylene sheet Polyethylene sheet Polyethylene sheet Sound pressure level (measured in anechoic room) dB <A> Insulation material Air filter PP honeycomb PP honeycomb PP honeycomb PP honeycomb Protection device Fuse Fuse Fuse Fuse Refrigerant control device LEV LEV LEV LEV Connectable outdoor unit R410A CITY MULTI R410A CITY MULTI R410A CITY MULTI R410A CITY MULTI Diameter of refrigerant pipe Liquid (R410A) mm(in.) 6.35(1/4) Flare 6.35(1/4) Flare 9.52(3/8) Flare 9.52(3/8) Flare Gas (R410A) mm(in.) 12.70(1/2) Flare 12.70(1/2) Flare 15.88(5/8) Flare 15.88(5/8) Flare mm(in.) Field drain pipe size Drawing Optional parts I.D. 16(5/8) I.D. 16(5/8) I.D. 16(5/8) - - - - Wiring - - - - Refrigerant cycle - - - - Document Installation Manual, Instruction Book Installation Manual, Instruction Book Installation Manual, Instruction Book Installation Manual, Instruction Book Accessory - - - - External LEV Box - - - - PAC-SH75DM-E PAC-SH75DM-E PAC-SH94DM-E PAC-SH94DM-E Drain pump Remarks Notes : * Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual. * Due to continuing improvement, above specification may be subject to change without notice. *1 Nominal cooling conditions (subject to JIS B8615-1) Indoor : 27degC D.B. / 19degC W.B. (81degF D.B. / 66degF W.B.) Outdoor : 35degC D.B. (95degF D.B.) Pipe length : 7.5 m (24-9/16 ft.) Level difference : 0 m (0 ft.) *2 Nominal cooling conditions *3 Nominal heating conditions (subject to JIS B8615-1) 27degC D.B. / 19.5degC W.B. 20degC D.B. Unit converter kcal/h = kW x 860 (81degF D.B. / 67degF W.B.) (68degF D.B.) BTU/h = kW x 3,412 35degC D.B. 7degC D.B. / 6degC W.B. cfm = m3/min x 35.31 (95degF D.B.) (45degF D.B. / 43degF W.B.) lbs = kg / 0.4536 5 m (16-3/8 ft.) 7.5 m (24-9/16 ft.) 0 m (0 ft.) 0 m (0 ft.) *The specification data is subject to rounding variation. *4 Electrical characteristic of cooling are included optional drain-pump. INDOOR UNITS 1 - 151 PKFY Standard attachment I.D. 16(5/8) External 3 24.4 54 5 R1 295 5 R1 R8 45 Knock out hole for under piping Knock out hole of remocon wiring Knock out hole for left piping 45 16 R8 91.5 2.5 10 695 Air outlet 640 Air intake 640 Air intake 815 10 R8 34 Knock out hole of right piping Knock out hole for remocon wiring 520 Liquid pipe 450 Gas pipe 660 (Drain pipe total 760) 50 116 110 N The first side L The second side M1 Terminal block Detailed 3 106.7 115 M2 60 100.6 14 Air intake 328 328 407.5 Terminal block Installation plate 4-4.5x35 hole 8- 4.3 hole Connection No. Address setting digit Address board 5 Mode selection * Address board is protected With PL cover. Remove the screw with driver on the occasion of setting. Address board Detailed 7 225 Operation lamp 90 102.5 124 DEFROST/STAND BY lamp Emergency operation switch <Heating> Emergency operation switch <Cooling> 159 133 122.5 97.5 85 72.5 60 47.5 22.5 0 15 225 205 175 170 Min 22mm 85 155 180 190 260 235 Gas pipe Liquid pipe Drain pipe Refrigerant piping 65 35 10 0 27.5 40 53 65 87 113 128 168 135 125 110 16mm(I.D) 1/2F( 12.7mm) 1/4F( 6.35mm) Min 50mm Max 90mm 60mm or more for left and left back piping. Piping hole 4-4.5x37 hole 4-4.5x40 hole 407.5 Note.1 Use M10 or W3/8 screw for installation plate. Note.2 Extension piping side. Note.3 In case of connecting MA-remote controller, please connect MA-remote controller cable (accessory) to the connector. Min 20mm 260 87- 5.1 hole Knock of hole 120 Installation space 12- 2.8 hole 4- 9 hole 85 Detail of installation plate 190 159 155 120 295 Installation plate balance point hole 10 0 10 30 0 30 45 50 44 Installation plate MA-remote controller (DC8.7-13V) There is not MA-remote controller terminal block. Connection with MA-remote controller refers to Note.3 Power supply (220-240V) Transmission (DC 24-30V) Air outlet (Direction) 74.6 Air outlet Address board Air intake (Direction) Power supply Transmission Air intake (Direction) Receiver 37.8 225 170 175 205 235 783 16 Detailed figure dwg(A B C) (Knock out hole) 45 5 10 50 2 4 INDOOR UNITS R1 2.5 Air outlet 298 298 Min 100mm PKFY 2. EXTERNAL DIMENSIONS DATA G8 2. EXTERNAL DIMENSIONS PKFY-P15, 20, 25VBM-E Unit : mm R1 5 1 - 152 0 16 28.5 41 78.5 91 103.5 116 166 178.5 203.5 232.5 253.5 77- 5.1 Tapping screw hole 43 394 A 56 278.3 12.5 449 C 43 4- 9 Bolt hole 174 46 60 43 B D Mount board Min.50 Knockout hole for lower piping Left side Min.250 2.5 65~ 80 Knockout hole for lower piping 273.2 231.5 128.5 153.5 21.8 0 20 32.7 53.5 66 Indoor unit outline 65~ 80 Sleeve Through hole (purchased locally) Center measurement hole 59 Min.7 250mm or greater with optional drain pump installation. 372.3 356.3 327.5 46 56 291.5 265 56 6 70 6 225 200 238 213 0 15 0 15 0 58 3.8 70 Knockout hole for piping 125 115 140 167 180.3 193.5 69 125 43 Min.150 281 295 8 Min.50 550mm or greater with optional Min.220 drain pump installation. 200 225 238 265 291.5 327.5 356.3 372.3 INDOOR UNITS 449 197 C 55 55mm or greater with left or rear left pipng or drain pump installation. 688 898 192 612 B Mount board 5 A Emergency operation switch (cooling / heating) Terminal block for MA-remote controller Terminal block for transmission Terminal block for power supply Knockout hole for right piping 249 Right side Operation lamp O.D Gas pipe 16 Refrigerant pipe : 12.7 Flared connection : 1/2F Liquid pipe Drain hose Size P32 P40 P50 Refrigerant pipe : 6.35 Flared connection : 1/4F DEFROST / STABD BY lamp 169 158 184 155 Front side Top side Operation lamp Knockout hole for lower piping Under side 457 Gas pipe 539 Liquid pipe 610 Drain hose Front side (Grille open) 599 Louver (manual) Vane (auto) 387 PKFY-P32, 40, 50VHM-E PKFY Required space (Indoor unit) 2. EXTERNAL DIMENSIONS DATA G8 Unit : mm 1 - 153 2. EXTERNAL DIMENSIONS DATA G8 PKFY-P63, 100VKM-E Unit : mm Top side 431.7 11 140.3 65.2 423.7 Left side Right side Front side Mount board 365 Knockout hole for left piping C 74 (855) A 241 295 5 1170 Operation lamp DEFROST/STAND BY lamp Front side (Grille open) Knockout hole for right piping Receiver Terminal block for power supply Terminal block for transmission Terminal block for MA-remote controller Emergency operation switch (cooling / heating) 30 35 444 (Gas pipe) 66 123 154 482 (Liquid pipe) 585 (Drain hose) 134 Under side Piping connection department 75 Gas pipe Refrigerant pipe : 15.88 Flared connection : 5/8F 16 Drain hose 75~ 80 O.D Louver (manual) Vane (auto) B B 54 0 Knockout hole for lower piping C B 3 Center measurement hole Φ2.5 364 384.5 408.5 439 454 465.5 314 Mount board 10 0 10 110 60 Temporarily fixing hole 314 75-Φ5.1 Tapping screw hole 454 439 408.5 384 364 Knockout hole for piping 517.4 4-Φ9 Bolt hole Indoor unit outline 54 32 25 A 15.5 87 37.5 62.5 50 75 100 117 125 142 192 67 77 77 7.8 77 65 67 7.8 65 10.7 65 12.5 12.5 0 0 25 104.5 129.5 167 217 242 279.5 292 87.5 229.5 264 292 308.5 311 R3 Min. 220 550 mm or greater with optional drain-up mechanism installation Min. 50.5 585 439 449.2 339 349.2 384 Knockout hole for left rear piping (75×480) 216.5 0 189 339 384 439 430.5 585 Min. 48 Air outlet Min. 72.4 Wall hole for left rear piping Wall hole for right rear piping 108 mm or greater with left or rear left piping or drain-up mechanism installation Min. 250 Min. 7 Air inlet 530.5 7.5 Required space (Indoor unit) 265 mm or greater with optional drain-up mechanism installation PKFY Sleeve Through hole (purchased locally) Liquid pipe Size P63 P112 Refrigerant pipe : 9.52 Flared connection : 3/8F 60 110 32 18 53 Filter hook INDOOR UNITS 1 - 154 3. CENTER OF GRAVITY DATA G8 3. CENTER OF GRAVITY Z H PKFY-P-VBM-E, VHM-E, VKM-E X Y W D Model W D H X Y Z PKFY-P15VBM-E 815 225 295 120 300 150 PKFY-P20VBM-E 815 225 295 120 300 150 PKFY-P25VBM-E 815 225 295 120 300 150 PKFY-P32VHM-E 898 249 295 120 390 160 PKFY-P40VHM-E 898 249 295 120 390 160 PKFY-P50VHM-E 898 249 295 120 390 160 PKFY-P63VKM-E 1170 295 365 190 460 190 PKFY-P100VKM-E 1170 295 365 190 460 190 PKFY INDOOR UNITS 1 - 155 4. ELECTRICAL WIRING DIAGRAMS DATA G8 4. ELECTRICAL WIRING DIAGRAMS PKFY-P15, 20, 25VBM-E Legend Symbol Name I.B Indoor controller board CN32 Connector Remote switch Centrally control CN51 Remote indication CN52 Capacity code SW2 Switch SW3 Mode selection P.B Indoor power board ZNR Varistor FUSE Fuse (T6.3AL 250V) F.C Fan phase control C1 Capacitor (Fan motor) MF Fan motor Symbol MV LEV TB2 TB5 TH21 Symbol Name Vane motor SW5 Linear expansion valve SW11 SW12 Terminal Power supply block Transmission SW14 Thermistor Room temp.detection W.B (0°C/15kΩ,25°C/5.4kΩ) RU Pipe temp.detection/Liquid BZ TH22 (0°C/15kΩ,25°C/5.4kΩ) LED1 Pipe temp.detection/Gas LED2 TH23 (0°C/15kΩ,25°C/5.4kΩ) SW1 Address board A.B SW2 Mode selection SW1 Switch RED 1 WHT BLU ORN YLW 5 M LEV W.B 5 6 9 9 TH23 1 SW1 12345678910 SW12 SW11 0 0 (RED) 4 ADDRESS CN43 1 CN51 5 1 CN52 8 SW3 SW2 1 4 1 8 CN81 CN42 ADDRESS ADDRESS (RED) (RED) ON OFF 12345678910 1234 3 1 CN32 1 4 CN41 1 2 CN2M M-NET (BLU) FAN (GRN) 1 1 3 CN35P (BLU) 1 3 1 2 CN3A CN20 MAINTAKE REMOCON (RED) (BLU) CN53P (RED) CND 1 (RED) F.C 3 PULL BOX FUSE (16A) BREAKER (16A) POWER SUPPLY ~/N 220-240V 50Hz ~/N 220V 60Hz C1 ZNR 5 GRN /YLW 6 RED 4 BLU BLK 1 2 1 2 CN29 CN21 GAS LIQUID (BLK) (WHT) 9 CN90 WIRELESS (WHT) 5 4 (RED) 8 ADDRESS CN82 SW14 0 1 WHT 1 CN5V 5 VANE (BLU) RED BLU M 1~ ORN A.B 240V t° MF 1 CN60 6 LEV (WHT) SW5 t° WHT YLW ORN BLU RED BRN LED1 LED2 PKFY TB2 L N 1 2 BLU t° ON OFF TO NEXT INDOOR UNIT MV CNB BZ 220V TH22 TH21 TO OUTDOOR UNIT BC CONTROLLER M-NET REMOTE CONTROLLER DC24-30V M1 M2 TB5 SW2 RU TO MA-REMOTE CONTROLLER DC8.7-13V ORN SW1 M Name Voltage selection Address setting 1s digit Address setting 10ths digit Connection No. Wireless remote controller board Receving unit Buzzer LED(Operation indicator:Green) LED(Preparation for heating:Orange) Emergency operation (Heat) Emergency operation (Cool) Switch FUSE 250V 6.3A U 1 1 10ths 1s CONNECTION DIGIT DIGIT No. 3 1 CN35M (BLU) See fig :*1 5 1 CN53M LED2 (RED) LED1 I.B P.B Note 1.At servicing for outdoor unit, always follow the wiring diagram of outdoor unit. 2.In case of using MA-remote controller,please connect MA-remote controller cable in an accessory to the connector 1 2 (Remote controller wire is non-polar.) 3.In case of using M-NET,please connect to TB5 (Transmission line is non-polar.) 4.Symbols used in wiring diagram above are, : terminal block, : connector 5.The setting of the SW2 dip switches differs in the capacity. For the detail, refer to the fig :*1. 6.Please set the switch SW5 according to the power supply voltage. Set SW5 to 240V side when the power supply is 230 and 240 volts. When the power supply is 220 volts, set SW5 to 220V side. LED on indoor board for service Mark Meaning LED1 Main power supply LED2 Power supply for MA-Remote controller Function Main power supply (indoor unit:220-240V) power on lamp is lit Power supply for MA-Remote controller on lamp is lit <*1> MODELS P15 SW2 ON OFF MODELS P20 1 2 3 4 SW2 ON OFF MODELS P25 1 2 3 4 INDOOR UNITS SW2 ON OFF 1 2 3 4 1 - 156 4. ELECTRICAL WIRING DIAGRAMS DATA G8 PKFY-P32, 40, 50VHM-E SYMBOL I.B CN32 CN51 CN52 BZ DSA FUSE LED1 LED2 SW2 SW3 SW4 SWE X1 MOV 01.02 LEV MF MV TB2 TB5 TB15 NAME NAME SYMBOL INDOOR CONTROLLER BOARD TH21 THERMISTOR ROOM TEMP. DETECTION (0°C/15kΩ, 25°C/5.4kΩ) CONNECTOR REMOTE SWITCH CENTRALLY CONTROL TH22 PIPE TEMP. DETECTION / LIQUID (0°C/15kΩ, 25°C/5.4kΩ) REMOTE INDICATION BUZZER TH23 PIPE TEMP. DETECTION / GAS1 (0°C/15kΩ, 25°C/5.4kΩ) SURGE ABSORBER FUSE (T3.15AL 250V) TH24 PIPE TEMP. DETECTION / GAS2 (0°C/15kΩ, 25°C/5.4kΩ) POWER SUPPLY (I.B) POWER SUPPLY (I.B) ADDRESS BOARD A.B SWITCH CAPACITY CODE SWA SWITCH FAN SPEED SELECTOR MODE SELECTION SW1 MODE SELECTION MODEL SELECTOR SW11 ADDRESS SETTING 1s DIGIT DRAIN PUMP (TEST MODE) ADDRESS SETTING 10ths DIGIT SW12 AUX.RELAY DRAIN PUMP (OPTION) SW14 BRANCH No. VARISTOR S.B SWITCH BOARD SWE1 EMERGENCY OPERATION(HEAT) LINEAR EXPANSION VALVE FAN MOTOR SWE2 EMERGENCY OPERATION(COOL) VANE MOTOR W.B PCB FOR WIRELESS REMOTE CONTROLLER TERMINAL POWER SUPPLY LED1 LED(OPERATION INDICATOR:GREEN) TRANSMISSION LED2 LED(OPERATION FOR HEATING :ORANGE ) BLOCK MA-REMOTE CONTROLLER RU RECEIVING UNIT DRAIN PUMP (OPTION) DP DRAIN FLOAT SWITCH (OPTION) FS TB2 RED L BLU N GRN/YLW MV LEV M 1~ M M FUSE CNP 3 (BLU) MOV2 MOV1 DSA X1 3 5 VANE 1 CN151 (WHT) U LED1 U 1 LDSWE(A) (BLU) 5 BRN RED BLU ORN YLW WHT 5 6 CNRU (WHT) 1 6 FLOAT SW CN4F (WHT) 4 BZ SWE CN32 (WHT) 8 ADDRESS CN81 (RED) 1 1 LED1 S.B When attaching drain pump(option), remove the jumper connector CN4F and fit the drain float switch (FS). When attaching drain pump (option) 1 4 <fig: 1> TH24 Models t ○ TH23 t FS FLOAT SW CN4F (WHT) SW2 P32 ON OFF P40 ON OFF P50 ON OFF ○ LIQUID/GAS1 CN44 (WHT) ADDRESS 4 1 CN42 4 (RED) 1 INTAKE CN20 (RED) 2 1 TH22 t ○ TH21 t ○ LED2 123456 PKFY 3 SWE1 SWE2 1 GAS2 CN2G (BLK) 2 1 OFF ON DC311~339V RECTIFICATION W.B CN52 (GRN) 5 CN51 1 (WHT) CN24 (YLW) 2 1 1 LEV CN60 (YLW) 1 LD101(B) RU I.B CND (BLK) GRN YLW ORN RED BRN BLK WHT YLW BLU 1 6 1 LD SWE(B) LED2 123456 123456 4 SW1 ON OFF TB15 1 0 1 9 10ths DIGIT 0 1 ADDRESS CN82 (RED) SW14 E 1s DIGIT F0 1 2 3456 TO OUTDOOR UNIT BC CONTROLLER REMOTE CONTROLLER DC24-30V 9 2 3 M1 M2 S (SHIELD) TB5 TO MA-REMOTE CONTROLLER DC8.7-13V 2 3 2 3 2 1 1 2 3 4 5 6 7 8 9 10 SWA SW12 SW11 BCD See fig: 1 ADDRESS CN43 (RED) 3 7 8 1 8 7 8 12345678 ORN 1234 MA-REMOCON CN3A (BLU) ORN BLU BLU SW3 5 6 SW4 4 M-NET SW2 CN2M(BLU) ON OFF 1 2 123456 5 6 3 FAN CNMF (WHT) 6 DP 4 1 3 TO NEXT INDOOR UNIT 789A RED MS 3~ POWER SUPPLY ~/N220-240V 50Hz 220V 60Hz RED BLU BLK MF FUSE BREAKER PULL (16A) (16A) BOX BRANCH No. A.B LED on indoor board for service Mark Meaning LED1 Main power supply LED2 Power supply for MA-Remote controller Function Main power supply (Indoor unit:220-240V) Power on → Iamp is lit Power supply for MA-Remote controller on → Iamp is lit NOTES: 1.At servicing for outdoor unit,always follow the wiring diagram of outdoor unit. 2.In case of using MA-Remote controller, please connect to TB15. (Remote controller wire is non-polar.) 3.In case of using M-NET, please connect to TB5. (Transmission line is non-polar.) 4.Symbol [S] of TB5 is the shield wire connection. 5.Symbols used in wiring diagram above are, : terminal block, :connecter. 6.The setting of the SW2 dip switches differs in the capacity. for the detail, refer to the fig: 1. INDOOR UNITS 1 - 157 4. ELECTRICAL WIRING DIAGRAMS DATA G8 PKFY-P63, 100VKM-E SYMBOL I.B CN32 CN51 CN52 BZ DSA FUSE LED1 LED2 SW2 SW3 SW4 SWE X1 MOV 01.02 LEV MF MV TB2 TB5 TB15 DP M 1~ FUSE BREAKER (16A) PULL (16A) BOX LD SWE(B) LEV LED2 LD101(B) M 1 5 FUSE CNP 3 (BLU) DSA 5 VANE 1 CN151 (WHT) MOV2 X1 MOV1 LED1 6 CNRU 1 (WHT) 5 6 1 LEV CN60 (YLW) 1 5 CN51 1 (WHT) CN24 (YLW) 2 1 CN32 (WHT) 3 ADDRESS CN81 (RED) 8 1 1 ORN ORN BLU BLU 12345678 1 When attaching drain pump (option) FLOAT SW CN4F (WHT) FS 1 4 <fig: 1> t○ Models TH23 LIQUID/GAS1 CN44 (WHT) ADDRESS 4 1 CN42 4 (RED) 1 INTAKE CN20 (RED) 2 1 P63 t○ TH22 t○ SW2 ON OFF ON P100 OFF TH21 t○ 123456 123456 4 8 ADDRESS CN43 (RED) 3 SW1 TB15 1 See fig: 1 S.B TH24 MA-REMOCON CN3A (BLU) SW3 LED1 When attaching drain pump(option), remove the jumper connector CN4F and fit the drain float switch (FS). LED2 M-NET SW4 SW2 CN2M(BLU) ON OFF 1 2 123456 1234 SWE1 SWE2 1 GAS2 CN2G (BLK) 2 1 DC311~339V RECTIFICATION W.B CN52 (GRN) FLOAT SW CN4F (WHT) 4 BZ U PKFY RU I.B 3 1 LDSWE(A) (BLU) GRN YLW ORN RED BRN RED BLK WHT YLW BLU 3 6 1 FAN CNMF (WHT) 3 6 TO NEXT MV INDOOR UNIT M CND (BLK) 1 POWER SUPPLY ~/N220-240V 50Hz 220V 60Hz BRN RED BLU ORN YLW WHT MS 3~ TB2 RED L BLU N GRN/YLW RED BLU BLK MF NAME NAME SYMBOL INDOOR CONTROLLER BOARD TH21 THERMISTOR ROOM TEMP. DETECTION (0°C/15kΩ, 25°C/5.4kΩ) CONNECTOR REMOTE SWITCH CENTRALLY CONTROL TH22 PIPE TEMP. DETECTION / LIQUID (0°C/15kΩ, 25°C/5.4kΩ) REMOTE INDICATION BUZZER TH23 PIPE TEMP. DETECTION / GAS1 (0°C/15kΩ, 25°C/5.4kΩ) SURGE ABSORBER FUSE (T3.15AL 250V) TH24 PIPE TEMP. DETECTION / GAS2 (0°C/15kΩ, 25°C/5.4kΩ) POWER SUPPLY (I.B) POWER SUPPLY (I.B) ADDRESS BOARD A.B SWITCH CAPACITY CODE SWA SWITCH FAN SPEED SELECTOR MODE SELECTION SW1 MODE SELECTION MODEL SELECTOR SW11 ADDRESS SETTING 1s DIGIT DRAIN PUMP (TEST MODE) ADDRESS SETTING 10ths DIGIT SW12 AUX.RELAY DRAIN PUMP (OPTION) SW14 BRANCH No. VARISTOR S.B SWITCH BOARD SWE1 EMERGENCY OPERATION(HEAT) LINEAR EXPANSION VALVE FAN MOTOR SWE2 EMERGENCY OPERATION(COOL) VANE MOTOR W.B PCB FOR WIRELESS REMOTE CONTROLLER TERMINAL POWER SUPPLY LED1 LED(OPERATION INDICATOR:GREEN) TRANSMISSION LED2 LED(OPERATION FOR HEATING :ORANGE ) BLOCK MA-REMOTE CONTROLLER RU RECEIVING UNIT DRAIN PUMP (OPTION) DP DRAIN FLOAT SWITCH (OPTION) FS 2 M1 M2 S (SHIELD) TB5 TO MA-REMOTE CONTROLLER DC8.7-13V TO OUTDOOR UNIT BC CONTROLLER REMOTE CONTROLLER DC24-30V 3 ON 2 OFF 1 1 2 3 4 5 6 7 8 9 10 SWA SW12 SW11 10ths DIGIT 1s DIGIT ADDRESS CN82 (RED) SW14 BRANCH No. A.B LED on indoor board for service Mark Meaning LED1 Main power supply LED2 Power supply for MA-Remote controller Function Main power supply (Indoor unit:220-240V) Power on → Iamp is lit Power supply for MA-Remote controller on → Iamp is lit NOTES: 1.At servicing for outdoor unit,always follow the wiring diagram of outdoor unit. 2.In case of using MA-Remote controller, please connect to TB15. (Remote controller wire is non-polar.) 3.In case of using M-NET, please connect to TB5. (Transmission line is non-polar.) 4.Symbol [S] of TB5 is the shield wire connection. 5.Symbols used in wiring diagram above are, : terminal block, :connecter. 6.The setting of the SW2 dip switches differs in the capacity. for the detail, refer to the fig: 1. INDOOR UNITS 1 - 158 5. SOUND LEVELS DATA G8 5-1. Sound levels 5. SOUND LEVELS Wall mounted Sound level at anechoic room : Low-(Middle2-Middle)-High Model Sound level dB (A) PKFY-P15VBM-E 29-31-32-33 PKFY-P20VBM-E 29-31-34-36 PKFY-P25VBM-E 34-37-41 PKFY-P32VHM-E PKFY-P40VHM-E 34-38-41 PKFY-P50VHM-E 34-39-43 PKFY-P63VKM-E 39-45 PKFY-P100VKM-E 41-49 1m Measurement location 1m * Measured in anechoic room. 5-2. NC curves External Static Pressure: 0Pa Power Source: 220-240V/50Hz, 220V/60Hz 70.0 High Low 65.0 50/60Hz 50/60Hz 60.0 NC-60 55.0 50.0 NC-50 45.0 40.0 NC-40 35.0 30.0 NC-30 25.0 20.0 15.0 10.0 Approximate minimum audible limit on continuous noise 63 125 250 500 NC-20 1k 2k 4k 70.0 50/60Hz 50/60Hz 60.0 NC-60 55.0 50.0 NC-50 45.0 40.0 NC-40 35.0 30.0 NC-30 25.0 20.0 15.0 10.0 8k High Low 65.0 Approximate minimum audible limit on continuous noise 63 Octave band center frequencies (Hz) 125 250 500 NC-20 1k 2k 4k Octave band pressure level (dB) 0dB=20μPa PKFY-P32VHM-E External Static Pressure: 0Pa Power Source: 220-240V/50Hz, 220V/60Hz Octave band pressure level (dB) 0dB=20μPa PKFY-P20, 25VBM-E External Static Pressure: 0Pa Power Source: 220-240V/50Hz, 220V/60Hz Octave band pressure level (dB) 0dB=20μPa PKFY-P15VBM-E 70.0 50/60Hz 50/60Hz 60.0 NC-60 55.0 50.0 NC-50 45.0 40.0 NC-40 35.0 30.0 NC-30 25.0 20.0 Approximate minimum audible limit on continuous noise 15.0 10.0 8k High Low 65.0 63 125 Octave band center frequencies (Hz) 250 NC-20 500 1k 2k 4k 8k Octave band center frequencies (Hz) External Static Pressure: 0Pa Power Source: 220-240V/50Hz, 220V/60Hz External Static Pressure: 0Pa Power Source: 220-240V/50Hz, 220V/60Hz 70.0 High Low 65.0 50/60Hz 50/60Hz 60.0 NC-60 55.0 50.0 NC-50 45.0 40.0 NC-40 35.0 30.0 NC-30 25.0 20.0 15.0 10.0 Approximate minimum audible limit on continuous noise 63 125 250 500 NC-20 1k 2k 4k 8k Octave band center frequencies (Hz) 70.0 High Low 65.0 50/60Hz 50/60Hz 60.0 NC-60 55.0 50.0 NC-50 45.0 40.0 NC-40 35.0 30.0 NC-30 25.0 20.0 15.0 10.0 Approximate minimum audible limit on continuous noise 63 125 250 500 NC-20 1k 2k 4k Octave band center frequencies (Hz) 8k Octave band pressure level (dB) 0dB=20μPa External Static Pressure: 0Pa Power Source: 220-240V/50Hz, 220V/60Hz Octave band pressure level (dB) 0dB=20μPa PKFY-P63VKM-E Octave band pressure level (dB) 0dB=20μPa PKFY-P50VHM-E 70.0 High Low 65.0 50/60Hz 50/60Hz 60.0 NC-60 55.0 50.0 NC-50 45.0 40.0 NC-40 35.0 30.0 NC-30 25.0 20.0 15.0 10.0 Approximate minimum audible limit on continuous noise 63 125 250 500 NC-20 1k 2k 4k 8k Octave band center frequencies (Hz) PKFY-P100VKM-E Octave band pressure level (dB) 0dB=20μPa External Static Pressure: 0Pa Power Source: 220-240V/50Hz, 220V/60Hz 70.0 High Low 65.0 50/60Hz 50/60Hz 60.0 NC-60 55.0 50.0 NC-50 45.0 40.0 NC-40 35.0 30.0 NC-30 25.0 20.0 15.0 10.0 Approximate minimum audible limit on continuous noise 63 125 250 500 NC-20 1k 2k 4k 8k Octave band center frequencies (Hz) INDOOR UNITS 1 - 159 PKFY PKFY-P40VHM-E 6. TEMPERATURE/AIRFLOW DISTRIBUTIONS DATA G8 6-1. Temperature distributions 6. TEMPERATURE/AIRFLOW DISTRIBUTIONS PKFY-P15-25VBM-E <Cooling mode> Horizontal air flow <Heating mode> Downward air flow [°C] 2.7 [°C] 2.7 2 2 Height (m) Height (m) 27 25 33 1 1 21 23 23 31 25 23 0 0 0 1 2 3 0 4 25 29 31 27 29 27 1 2 3 4 Floor distance (m) Floor distance (m) PKFY-P32-50VHM-E <Cooling mode> Horizontal air flow <Heating mode> Downward air flow [°C] [°C] 2.7 2.7 27 25 2 23 21 Height (m) Height (m) 2 23 1 35 27 23 1 PKFY 25 0 23 0 0 1 25 33 2 3 4 5 5.5 25 0 27 29 31 1 29 31 2 3 Floor distance (m) 4 5 5.5 Floor distance (m) PKFY-P63, 100VKM-E <Cooling mode> Horizontal air flow <Heating mode> Downward air flow [°C] [°C] 25 2.7 2.7 23 2 27 Height (m) Height (m) 2 21 1 25 1 25 1 2 25 31 29 29 31 23 0 0 27 33 3 4 5 6 7 8 0 0 1 2 3 4 5 6 7 8 Floor distance (m) Floor distance (m) Note : These figures show typical temperature distributions in the conditions above. In the actual installation, they may differ from these figures under the influence of air temperature conditions, ceiling height, cooling/heating load,obstacles,etc. INDOOR UNITS 1 - 160 6. TEMPERATURE/AIRFLOW DISTRIBUTIONS DATA G8 6-2. Airflow distributions PKFY-P15-25VBM-E <Fan mode> Horizontal air flow [m/s] [m/s] 2.7 2 2 Height (m) 2.7 Height (m) <Fan mode> Downward air flow 3.0 2.0 1.0 1 3.0 2.0 1 0.5 1.0 0 0 1 2 3 4 0.5 1.0 0.5 0 0 1 2 Floor distance (m) PKFY-P32-50VHM-E <Fan mode> Horizontal air flow 4 <Fan mode> Downward air flow [m/s] [m/s] 2.7 2.7 4.0 2 0.5 3.0 Height (m) 2 Height (m) 3 Floor distance (m) 2.0 1 4.0 3.0 1 1.0 0.5 0 0 1 2 3 4 5 5.5 2.0 1.0 0 0 1 2 3 4 5 5.5 Floor distance (m) PKFY-P63, 100VKM-E <Fan mode> Horizontal air flow 2.7 0.5 1.0 Floor distance (m) PKFY 0.5 <Fan mode> Downward air flow [m/s] 2.7 4.0 3.0 [m/s] 4.0 2 2 0.5 3.0 Height (m) Height (m) 2.0 1 0.5 1.0 1 2.0 0.5 1.0 0 0 1 2 3 4 5 6 7 8 0 0 1 1.0 2 0.5 3 4 5 6 7 8 Floor distance (m) Floor distance (m) Note : These figures show typical airflow distributions in the conditions above. In the actual installation, they may differ from these figures under the influence of air temperature conditions, ceiling height, cooling/heating load,obstacles,etc. INDOOR UNITS 1 - 161 7. OPTIONAL PARTS DATA G8 7. OPTIONAL PARTS 7-1. Optional parts line up for the Indoor unit External LEV Box Drain pump PKFY-P15, 20, 25VBM-E PAC-SG95LE-E — PKFY-P32, 40, 50VHM-E — PAC-SH75DM-E PKFY-P63, 100VKM-E — PAC-SH94DM-E 7-2. External LEV Box Item Quantity 2 Joint pipe 2 1 External LEV Box 1 3 Pipe cover 4 Band 2 2 5 Fastener 2 Cable(100mm) Cable(5300mm) Shape Detailed installation information should be referred to its Installation Manual (RG79A417K01) 7-3. Drain pump PAC-SH75DM-E If drain water can not flow out the Indoor unit by gravity and gradient, a Drain-pump for draining is needed. Drain pump PAC-SH75DM-E can pump water up to 800mm high from the drain pan. Item Quantity 1 Drain pump 1 2 Screw (M4×16)×1, (M4×35)×6 3 Drain hose 1 7 Installtion plate 1 8 Wiring diagram 4 Drain hose cover 1 5 Hose band 1 Shape PKFY Item Quantity 6 Band 1 1 Shape Detailed installation information should be referred to its Installation Manual (RG79Y375H01) PAC-SH94DM-E If drain water can not flow out the Indoor unit by gravity and gradient, a Drain-pump for draining is needed. Drain pump PAC-SH94DM-E can pump water up to 800mm high from the drain pan. 1 Drain pump 1 2 Screw (M4×16)×1, (M4×35)×6 3 Drain hose 1 Item 6 Band 7 Installtion plate 8 Wiring diagram Quantity 1 Item Quantity 4 Drain hose cover 1 5 Hose band 1 Shape 1 1 Shape Detailed installation information should be referred to its Installation Manual (RG79Y376H01) INDOOR UNITS 1 - 162
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement