Sanyo Denki SANUPS E11A102A is a 1kVA Hybrid UPS that provides reliable power protection for your sensitive equipment. It features three modes of operation - Economy, Active Filter, and Double Conversion - to ensure efficient power usage and reliability. The SANUPS E11A102A can automatically switch to battery power during outages, providing up to 5 minutes of backup time. It also includes a self-battery check feature to maintain peak battery conditions.
advertisement
![Sanyo Denki SANUPS E11A102A Specifications | Manualzz Sanyo Denki SANUPS E11A102A Specifications | Manualzz](http://s1.manualzz.com/store/data/001799107_1-9855bf6222a1b241e76da8795e26f51b-360x466.png)
HYBRID UPS
E11A
Hybrid UPS Saves Energy and Achieves High Reliability
SANUPS
HYBRID UPS
100V model
E11A
19 inch rack
Mountable
EIA
UL (E226092), CE, FCC Part15 Subpart B Class A
Input
AC100,110,115,120V
Single-phase
200V model
Input
AC200,208,220,230,240V
Single-phase
Output
AC100,110,115,120V
Single-phase
Output
AC200,208,220,230,240V
Single-phase
1 kVA
Output capacity
1.5 kVA 2 kVA 3 kVA
(1.4 kW) (2.1 kW)
1 kVA
(0.7 kW)
Output capacity
2 kVA
(1.4kW)
3 kVA
(2.1kW)
The advancement of technology has increased the demand for quality power. In a perfect world, commercial power would always be stable and normal, however, we live in a world in which electricity from local utilities typically experiences anomalies such as spikes, surges, electrical noise, load fluctuations, and outages.
To protect your investments in technology equipment from these problems, informed users rely on
SANYO DENKI SANUPS E11A products to resolve these power issues and provide continuous, clean power to connected equipment. Not only does the SANYO DENKI SANUPS E11A create continuous and clean power, it is an intelligent device in which power is consumed only when power conditions are unfavorable, making the unit highly efficient.
The SANYO DENKI SANUPS E11A Hybrid UPS provides highly efficient power protection to everything from heavy machinery and manufacturing devices to complex server systems and sensitive communication equipment (Voice and Data). With over 40 years of UPS experience, SANYO DENKI ensures the superior quality of the SANUPS E11A Hybrid UPS and provides the product equipped with extra long life batteries. The SANUPS E11A Hybrid UPS - a product truly in a class of its own.
2
1
Hybrid UPS-Energy conservation
2
Self battery check feature
3
UPS Management options
Mounted in a 19-inch rack
● Includes metal brackets for 19 inch rack installation.
● Rack support rail is optional.
Vertical Installation
● Includes vertical stand for upright support.
Hybrid UPS-Energy conservation
SANYO DENKI combines both line interactive and double conversion
UPS technologies in the SANUPS E11A Hybrid UPS, delivering
3 modes of operation for high efficiency and reliability.
Conversion efficiency of the SANUPS E11A is increased by 4%* compared to comparable online UPS.
Conversion
Efficiency
95
%
Commercial
Power
SANUPS E11A
* It is a result of comparing the performances with existing 1kVA UPS of our company.
The Hybrid type SANUPS E11A automatically selects the most efficient mode of operation for any given power condition.
Operating mode can be manually chosen and locked by the end user.
Load Device
Three different modes of operation:
When power conditions are good.
ECONOMY mode
Hybrid
Method
SANUPS E11A
Harmonic noise
When load power fluctuates.
Suppresses high frequencies generated by load and improves power factor.
When power conditions fluctuate.
Momentary blackout Voltage fluctuation
Frequency fluctuation Harmonic noise
Self battery check feature
The SANUPS E11A automatically performs regular battery tests for operation during a power outage, and maintains peak battery conditions for reliable operation during an actual power outage.
* The frequency of the battery test is open to configuration. (Test frequency choices are 1, 3 and 6 months; the factory setting is 6 months.)
* Sudden stoppage does not occur during battery operation test, no matter what the power supply mode.
* A LAN interface card (optional) is necessary to transmit the battery test results to the user’s PC.
Begin Testing
Normal Operation Battery Test
Rectifier Inverter Rectifier Inverter
Periodic
Check
Battery Battery
Return to Normal Operations * If a decline in the battery function is detected during test mode, normal operation will resume.
3
4
3
UPS Management options
To increase user control over equipment protection, our stand-alone windows compatible UPS Management
Software “SANUPS SOFTWARE STANDALONE” is provided as a standard accessory. Use it to improve the utility of the UPS, through useful functions such as monitoring UPS performance over a network connection and configuring shutdown settings.
SANUPS SOFTWARE
STANDALONE
PC
RS232C
SANUPS E11A
OS
for Windows
Options
LAN Interface Card
A LAN Interface Card (100Base-TX) can be inserted in the optional card slot on the rear panel of the SANUPS
E11A. This allows for continuous monitoring and reporting of power conditions, and quick response during power failures. Power problems can also be reported to the System
Manager via e-mail when this Card is installed.
Model : PRE11A01-US
for Windows,UNIX,Linux
OS
SANUPS SOFTWARE
The SANUPS SOFTWARE UPS Power
Management Software increases the reliability and manageability of the entire system, including the network and the server. It provides UPS information to the
System Manager, and flexible settings for handling power-related problems.
Model for Windows PMS40C00E ( without cable ) for Multiple OS PMS41C00E ( without cable )
Note: Corresponds to all left OS.
Front
Battery Power Low LED
Input LED
Output LED
Alarm LED
Inverter Switch
Battery Test Switch
Clear Switch
Supply Mode LED
Load Level Display
Back
The photograph shows the 100 V model 1kVA E11A102A011.
EPO, Systematic Control Contact Point
PC Interface
(RS-232C)
Option Card
Interface
Remote Interface
External Battery Connection Port
Power Switch (ON/OFF)
Option Card Slot
Output Plug /
Connection
Input Cable
(1.8m / 5.91feet)
Input Plug /
Connection
Interface & INPUT/OUTPUT Connection Chart
100V model
(100 to 120V)
200V model
(200 to 240V)
Output UL /CE Model
(kVA)
1
1.5
2
3
1
2
○
○
○
○
○
○
○
○
○
○
○
E11A102A001
E11A102A011
E11A152A001USJ
E11A152A011USJ
E11A202A001USJ
E11A202A011USJ
E11A302A001USJ
E11A302A011USJ
E11A102A002USJ
E11A102A012USJ
E11A202A002USJ
E11A202A012USJ
PC Remote EPO Systematic
(RS-232C) Control
Contact
Point
○ ― ― ―
○
○
○
○
○
―
○
―
○
―
○
―
○
―
○
―
○
○
○
○
○
○
○
―
○
―
○
―
○
―
○
―
○
―
○
―
○
―
○
―
3
○
○
○
E11A302A002USJ
E11A302A012USJ
○
○
○
○
―
○
○
―
○
○
―
○
LAN Interface card
(Option)
Model: PRE11A01-US
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Contact INPUT signal interface Plug/Connection card (Option)
PRE11A02-US
― NEMA 5-15P
○
NEMA 5-20P ―
○
― NEMA L5-30P
○
―
○
―
○
―
○
―
○
IEC60320-C14 to NEMA L6-20P line cord option included.
IEC60320-C20 to NEMA L6-20P line cord option included.
OUTPUT
Plug/Connection
NEMA 5-15R×6
NEMA 5-20R×4
NEMA L5-30R×1
IEC60320-C13×4
IEC60320-C19×3
5
Specifications
Item
Output power
System Topology
AC Input
Cooling
Number of phase / wire
Nominal 100V model voltage (1kVA/1.5kVA/2kVA/3kVA)
E11A
Economy mode* Active filter mode*
1kVA(0.7kW)/ 1.5kVA(1.05kW)/ 2kVA(1.4kW)/ 3kVA(2.1kW)**
Hybrid
Forced Air
Single-phase / 2 wire
AC100,110,115,120V
Double Conversion mode
Remarks
User selectable
AC Output
200V model
(1kVA/2kVA/3kVA)
Voltage range
Frequency
Frequency range
Power factor
Number of phase / wire
Power factor
Nominal 100V model voltage (1kVA/1.5kVA/2kVA/3kVA)
200V model
(1kVA/2kVA/3kVA)
AC200,208,220,230,240V
±8% Max.
50/60Hz Auto-sensing
±1,3,5% Max.
0.7(lag)
Single-phase / 2 wire
0.7(lag)
AC100,110,115,120V
AC200,208,220,230,240V
±5% Max.
0.85Min.
+15%,-20% Max.
±8%Max.
0.95Min.
User selectable
<1% Input voltage distortion
Fluctuation tolerance: 0.7(lag) to 1.0
Multiple output User selectable
Voltage regulation
Frequency
Frequency range On Normal Operation ±1,3,5% Max.
On Battery Operation -
Voltage distortion Linear load -
±8%Max.
50/60Hz Auto-sensing
±5%Max.
Battery regulation
Non-linear load
100% step load
Overcurrent capacity
-
Transient voltage Input Voltage step ±5%Max.
-
Greater than 200% (30 second interval)
Overcurrent protection
Type
Backup time
Greater than 800% (2 cycle)
Fuse Protection (1kVA), Breaker Protection (1.5, 2, 3kVA)
Maintenance Free Sealed Lead-Acid Battery (small)
5minutes (3kVA 100Vmodel: 3.5minutes)
Acoustic noise 1kVA/1.5kVA: 40dB MAX., 2kVA/3kVA: 45dB MAX.
±2%Max.
Depending on the input and load variance range
Same as input frequency
User selectable ±1% Max.
±0.5% Max.
3%Max.
7%Max.
During rated operations
During rated operations / 100% rectifier load
Power failure: feedback or supply fluctuation
±5%Max.
105%(200ms)
0% : at the time of 100% sudden fluctuation
Rated load power factor / at rated input
-
Bypass Non-Hit Change (Auto Return) Auto-return can be disabled
Ambient Temp. of 25 ℃, under rated load
At 1m (40in) from the front of unit ,
At Economy mode
Nominal heat dissipation
Environment Operating temperature
Relative humidity
Standard of safety
Double conversion mode
100Vmodel
1kVA: 125W, 1.5kVA: 200W, 2kVA: 250W, 3kVA: 410W
200Vmodel
1kVA: 125W, 2kVA: 270W, 3kVA: 450W
0 to 40 ℃ (32 to 104°
20 to 90%
UL(E226092), CE, FCC Part15 Subpart B Class A
Non-condensing
*A momentary power interruption lasting less than 3 ms occurs when switching from Economy Mode or Active Filter Mode to battery power.
The unit can also be fixed to the Double Conversion Mode for applications that require zero transfer time from utility power to battery power.
Please contact your local sales representative for additional input and ouput voltage options.
** When using only 3 kVA for the 100 V model as a UL certified product, the load must be reduced depending on the set voltage.
When set to 120 V = 3 kVA (2.1 kW), when set to 115 V = 2.87 kVA (2.013 kW), when set to 110 V = 2.75 kVA (1.925 kW), when set to 100 V = 2.5 kVA (1.75 kW)
External dimensions
W
PaintColor: Black
(Munsell N1.5)
Output power Dimensions
(kVA)
Width (W)
1kVA
1.5kVA
2kVA
3kVA (100V)
3kVA (200V)
Depth (D)
408mm (16.06in)
500mm (19.69in)
440mm (17.32in) 565mm (22.24in)
660mm (25.98in)
750mm (29.53in)
Height (H)
86mm (3.39in)
Mass (Weight) Remarks
17kg (37.5lbs) 100V/200V
22kg (48.5lbs) 100V
29kg (63.9lbs) 100V/200V
37kg (81.6lbs) 100V
39kg (86.0lbs) 200V
6
Run-time chart
700
800
900
1000
1200
1400
1500
1600
1800
2000
2200
2400
2600
2800
100
200
300
400
500
600
Item
Maximum Output (VA)
Maximum Output (W)
VA W
70
140
210
280
350
420
490
560
630
700
840
980
1050
1120
1260
1400
1540
1680
1820
1960
E11A102A □□□
1000
700
6
5
9
7
87
48
30
20
15
12
E11A152A □□□ E11A202A □□□
1500
1050
17
14
12
10
134
71
48
34
24
20
7
6
5
Run-time (Min)
2000
1400
25
20
18
15
150
87
61
48
37
30
8
7
6
5
12
9
E11A302A □□ 1
3000
2100
16
13
11
10
9
6
5
8
7
4
32
26
23
20
230
120
75
55
49
39
3000 2100 3.5
The above run-time value assumes a load power factor = 0.7.
Figures should be used for reference only. Actual backup times depend on charging conditions, ambient temperature, years in use, etc.
Option
E11A302A □□ 2
3000
2100
40
34
31
28
240
150
87
71
69
48
20
17
16
14
12
10
9
8
7
6
5
Item
Rack support rail
Remote switch
Contact signal interface card
Cable for coupled operations xxxxxxxx
Outlet box
Model
RM030
RSW006R
Used for mounting the UPS onto a 19 inch rack. Supports depth of 555mm-913mm.
Used for remotely turning on or off outlets 1,2 of the UPS.
PRE11A02
Transmits contact signals containing information on the operation status of the UPS.
Use to interface with UPS surveilance systems or customer equipment.
P10197
(1m),
P10198
(3m) Signal cable used to connect UPS units in order to control turning multiple units of UPS on and off.
P10037
(100V 1kVA, 1.5kVA) xxx
P10040 (100V 2kVA) Equipment used to divide UPS output into three systems with the UPS system control contact signal and control turning on or off.
P10030 (100V 3kVA) xxx
■External battery
Specifications
Mode l*
BCE11A102A01US
BCE11A102A02US
BCE11A152A01US
BCE11A152A02US
BCE11A202A01US
BCE11A202A02US
BCE11A302A03US for 1kVA 100V or 200V model mm )
Width for 1.5kVA 100V model for 2kVA 100V or 200V model for 3kVA 100V model only
440
Depth
408
508
500
600
565
630
660
Height
86
BCE11A302A01US for 3kVA 200V model only
750
* If the end of the model number is US: Product certified with UL Specifications.
Weight
20
29
26
38
34
47
50
52
Run-time (Min)
15
―
―
―
―
―
―
1unit
―
20
1unit
―
1unit
―
1unit
―
―
1unit
30
―
1unit
―
1unit
―
1unit
2unit
―
40
2unit
―
2unit
―
2unit
―
―
2unit
45
―
―
―
―
―
―
3unit
―
60
3unit
2unit
3unit
2unit
3unit
2unit
―
3unit
External dimensions
W
PaintColor: Black
(Munsell N1.5)
■Support rail
External dimensions
○Effective Dimensions (when fully retracted)
B
A
86.6mm
B
555mm
C
913mm
○ Effective Dimensions (when fully extended)
C
■ When expanded battery modules (model number ends with 01 or 03) are placed in rack mounting, the internal battery packs only can be exchanged from the front without removing the unit.
■ If the model number ends with 02, the module must be completely removed from the rack.
7
Notes when investigating use of this product in your applications
● Before starting installation, assembling and use, read the “Operation
Manual” carefully and use the product correctly in your applications.
● When you are going to use this product in the following application, the special considerations are required for operation, running, maintenance and control. Be sure to consult with our company as a part of your investigations.
(a) Medical equipment and other equipment that are related directly to human life.
(b) Train or elevator that can give injury to human body.
(c) Socially and publicly important computer systems
(d) And other equipment that are related to safety of human life and that can affect severe effects on maintenance of public functions.
● For the applications that undergo vibration such as vehicles, ships and transportation facilities, please consult with our company.
● Never modify this product or give additional processing to this product.
● For the installation and maintenance work, please consult with our company or with specialized company.
※ For any inquiry or consultation, please contact our sales representative. http://www.sanyodenki.co.jp
Phone: +81 3 3917 5157
1-15-1, Kita-Otsuka, Toshima-ku, Tokyo 170-8451, Japan
468 Amapola Avenue Torrance, CA 90501 U.S.A.
P.A. Paris Nord ll 48 Allee des Erables-VILLEPINTE BP.57286 F-95958 ROISSY CDG Cedex France
Frankfurter Strasse 63-69 65760 Eschborn Germany
9F 5-2, Sunwha-dong Jung-gu Seoul, 100-130, Korea
Room 2116, Bldg B, FAR EAST INTERNATIONAL PLAZA, No.317 XianXia Rd., Shanghai 200051 China
Room 1208, 12F, No.96 Chung Shan N, Rd., Sec.2, Taipei 104, Taiwan, R.O.C.
Phone: +1 310 783 5400
Phone: +33 1 48 63 26 61
Phone: +49 6196 76113 0
Phone: +82 2 773 5623
Phone: +86 21 6235 1107
Phone: +886 2 2511 3938
Room 2305, 23/F, South Tower, Concordia Plaza, 1 Science Museum Rd., TST East, Kowloon, Hong Kong Phone: +852 2312 6250
10 Hoe Chiang Road #14-03A/04 Keppel Towers Singapore 089315 Phone: +65 6223 1071
The names of companies and/or their products specified in this catalogue are the trade names, and/or trademarks and/or registered trademarks of such respective companies.
*Remarks : Specifications Are SubjectTo Change Without Notice.
CATALOG No.820-3 ’08.1.C
advertisement