IDFAE-B.qxd 07.6.26 4:57 PM Page 1

Refrigerated Air Dryer

For use in Europe and South East Asia

EC Directive compliant (with CE marking)

Power supply voltage:

Single-phase 230 VAC (50 Hz)

New

IDFA55E, 75E

are added!

Series

IDFA 쏔 E

Refrigerant

R134a ( HFC )

R407C ( HFC )

Coefficient of destruction for ozone is zero.

Improved corrosion resistance with the use of stainless steel, plate type heat exchanger (IDFA4E to 75E)

Series

IDFA3E

IDFA4E

IDFA6E

IDFA8E

IDFA11E

IDFA15E

IDFA22E

IDFA37E

IDFA55E

IDFA75E

Air flow capacity (m 3 /h [ANR])

Outlet air pressure dew point

3

°

C 7

°

C 10

°

C

65

80

120

182

273

390

660

12

24

36

15

31

46

83

101

152

231

347

432

720

91

112

168

254

382

510

822

17

34

50

Refrigerant

R134a (HFC)

R407C (HFC)

Rated inlet condition

35

°

C

0.7 MPa

Port size

Rc 3/8

Rc 1/2

Rc 3/4

Rc 1

R 1

R 1 1 /

2

R 2

CAT.ES30-9B

IDFAE-B.qxd 07.6.26 4:57 PM Page 2

INDEX

1. Standard Products

Series IDFA

Standard inlet air type

Rated inlet air temperature: 35

°

C

Model

IDFA3E

IDFA4E

IDFA6E

IDFA8E

IDFA11E

IDFA15E

IDFA22E

IDFA37E

IDFA55E

IDFA75E

Rated inlet condition

Air flow capacity (m 3 /h [ANR])

Outlet air pressure dew point

3

°

C 7

°

C 10

°

C

12 15 17

35

°

C

0.7 MPa

120

182

273

390

24

36

65

80

660

152

231

347

432

31

46

83

101

720

168

254

382

510

34

50

91

112

822

Refrigerant

R134a (HFC)

R407C (HFC)

Port size

Rc 3/8

Rc 1/2

Rc 3/4

Rc 1

R 1

R 1 1 /

2

R 2

Page

P. 3 to 5

P. 6 to 8

2. Options

Specifications

Cool compressed air output

Anti-corrosive treatment

For medium air pressure

(Auto drain bowl type: Metal bowl with level gauge)

With heavy duty auto drain

(For medium air pressure)

With circuit breaker

With terminal block for power supply, run & alarm signal and remote operation

With timer-type solenoid valve (Applicable to medium air pressure)

Applicable model

IDFA3E to 11E

IDFA3E to 75E

IDFA6E to 37E

IDFA4E to 75E

IDFA4E to 75E

IDFA4E to 75E

IDFA4E to 75E

Suffix

(Option symbol)

IDFA

E-23-A

IDFA

E-23-C

IDFA

E-23-K

IDFA 쏔 E-23-L

IDFA

E-23-R

IDFA

E-23-T

IDFA

E-23-V

Page

P. 9

P. 10

3. Optional Accessories

Description

Dust-protecting filter set

Foundation bolt set

Page

P. 11

4. Data (Condensed Water Calculation, Dew Point Conversion Chart) ··· P. 12

5. Safety Instructions ··· Back page 1 to 3

1

IDFAE-B.qxd 07.6.26 4:57 PM Page 3

Series

IDFA 쏔 E

Model Selection

The corrected air flow capacity, which considers the user’s operating conditions, is required for selecting the air dryer. Please select using the following procedures.

IDFA E Selection Example

1

Read the correction factor.

Obtain the correction factor A to D suitable for your operating condition using the table below.

Condition

Inlet air temperature

Ambient temperature

Inlet air pressure

Air consumption

40

35

°

°

0.5 MPa

31 m

C

C

3 /h

Note) Values obtained from the table below.

Data symbol

A

B

C

Correction factor Note)

0.83

0.83

0.92

2

Calculate the corrected air flow capacity.

Obtain the corrected air flow capacity from the following formula.

Corrected air flow capacity = Air consumption

(Correction factor A x B x C)

3

Select the model.

Select the model which air flow capacity exceeds the corrected air flow capacity using the specification table. (For air flow capacity, refer to the data D below.)

4 Option

Corrected air flow capacity = 31 m 3 /h 앦 (0.83 x 0.83 x 0.92) = 48.9 m 3 /h

According to the corrected air flow capacity of 48.9 m 3 /h, the IDFA8E will be selected when the required output air pressure dew point is 3

°

C. The

IDFA6E will be selected when the required pressure dew point is 10

°

C.

Refer to page 3, 6.

5

Finalize the model number.

Refer to page 3, 6.

6

Select accessories sold separately.

Refer to page 11.

Data A: Inlet Air Temperature Data B: Ambient Temperature

Inlet air temperature

(

°

C)

5 to 25

30

35

40

45

50

Correction factor

IDFA3E to 37E

1.30

1.25

1

0.83

0.7

0.6

IDFA55E to

1.33

1.16

1

0.8

0.64

0.48

75E

Ambient temperature

(

°

C)

20

25

30

35

40

Correction factor

IDFA3E to 11E IDFA15E to 75E

1.1 1.1

1

0.91

0.83

0.79

1

0.97

0.89

0.77

Data C: Inlet Air Pressure

Inlet air pressure

(MPa)

0.7

0.8

0.9

1

0.3

0.4

0.5

0.6

1.2

1.4

1.6

Correction factor

IDFA3E to 11E

0.80

0.87

0.92

0.96

1.00

1.04

1.07

1.1

1.16

1.21

1.25

IDFA15E to 75E

0.72

0.81

0.88

0.95

1.00

1.06

1.11

1.16

1.21

1.25

1.27

Data D: Air Flow Capacity

Air flow capacity (m 3 /h [ANR])

Model

IDFA3E IDFA4E IDFA6E IDFA8E IDFA11E

Outlet air pressure dew point

3

°

C

7

°

C

10

°

C

12

15

17

24

31

34

36

46

50

65

83

91

80

101

112

Note) In case of “Option A (Cool compressed air output)”, the air flow capacity is different. Refer to page 9 for details.

Model

Outlet air pressure dew point

3

°

C

7

°

C

10

°

C

Air flow capacity (m 3 /h [ANR])

IDFA15E IDFA22E

120 182

IDFA37E

273

IDFA55E

390

152

168

231

254

347

382

432

510

IDFA75E

660

720

822

2

IDFAE-B.qxd 07.6.26 4:57 PM Page 4

Refrigerant R134a (HFC)

Series

IDFA

3E, 4E, 6E, 8E, 11E, 15E

(Inlet air temperature: 35

°

C)

쏔 E

How to Order

IDFA 8 E

Size

Size

3

4

6

8

11

15

23

Note 1)

T

V

L

R

Nil

A

C

K

Symbol

23

Voltage

Voltage

Single-phase

230 VAC (50 Hz)

Options and Available Combinations (Size/Option)

Symbol Note 2)

Nil A C K

Size

Option

None

Cool compressed air output

Anticorrosive treatment

For medium air pressure

Auto drain bowl type:

Metal bowl with level gauge

L

With heavy duty auto drain

(Applicable to medium air pressure)

3

4

6

8

11

15

R

With circuit breaker

T V

With terminal block for run & alarm signal

With timer-type solenoid valve

(Applicable to medium air pressure)

Note 1) G thread (PF thread) can accept the R thread (PT male thread), thus making no “F” in the thread specification setting.

A conversion adaptor for the R thread (PT male thread) is also contained.

Note 2) Enter alphabetically when multiple options are combined.

However, the following combination cannot be achieved.

• Combination of K, L and V cannot be achieved because an auto drain can only be attached to a single option.

Note 3) Refer to page 9 for further details on optional specifications.

3

IDFAE-B.qxd 07.6.26 4:57 PM Page 5

Refrigerated Air Dryer

Series

IDFA 쏔 E

Standard Specifications

JIS Symbol

Refrigerated air dryer

Auto drain

Model

Specifications

Fluid

Inlet air temperature

Inlet air pressure (MPa)

Ambient temperature (Humidity)

Air flow

Note 1)

Standard condition

(ANR)

Outlet air pressure dew point

Outlet air pressure dew point

(

°

C)

(3

°

C)

(7

°

C)

Outlet air pressure dew point (10

°

C) capacity m 3 /h Com-

Note 2) pressor intake condition

Outlet air pressure dew point

Outlet air pressure dew point

Outlet air pressure dew point

(3

(7

°

°

C)

C)

(10

°

C)

Inlet air pressure

(

°

C)

Inlet air temperature

Ambient temperature

(MPa)

(

°

C)

(

°

C)

Power supply voltage

Power consumption

Operating current

Applicable circuit breaker capacity Note 4)

Condenser

Refrigerant

(W)

(A)

(A)

Auto drain

IDFA3E

Standard temperature air inlet

IDFA4E IDFA6E IDFA8E

Compressed air

IDFA11E IDFA15E

12

15

17

13

16

18

24

31

5 to 50

0.15 to 1.0

2 to 40 (Relative humidity of 85% or less)

36

46

65

83

80

101

34

25

32

35

50

37

48

52

91

68

86

95

112

83

105

116

0.7

35

25

Single-phase: 230 VAC [Voltage fluctuation

±

10%] 50 Hz

180 208 385 470

1.2

5

1.4

Air-cooled

2.7

3.0

10

R134a (HFC)

120

152

168

125

158

175

Float type

(Normally closed)

Float type

(Normally open)

Port size

Accessory

Weight

Coating color

(kg)

Rc 3/8

18

Rc 1/2

22

Rc 3/4

Hexagon nipple

23 27

Body panel: White 1

Base: Gray 2

28

Rc 1

46

Compliant standards EC Directive (with CE marking)

Note 1) Air flow capacity under the standard condition (ANR) [atmospheric pressure at 20

°

C, relative humidity at 65%]

Note 2) Air flow capacity converted by the compressor intake condition [atmospheric pressure at 32

°

C]

Note 3) Select air dryer according to the model selection method (page 2) for the models beyond the rated specifications.

Note 4) Install a circuit breaker with a sensitivity of 30 mA.

Note 5) When a short-term interruption of the power supply (including momentary interruption) occurs in this equipment, the restarting of normal operations may require some time or may be impossible due to the operation of protective devices even after the supply of power returns.

Replacement Parts

Model

Auto drain replacement parts no. Note 5)

IDFA3E IDFA4E IDFA6E

AD38

IDFA8E IDFA11E IDFA15E

Note 6) The part number for the auto drain components without including the body part.

Body part replacement is impossible.

AD48

Body

Auto drain

Construction (Air/Refrigerant Circuit)

Humid, hot air coming into the air dryer will be cooled down by a cooler re-heater

(heat exchanger). Water condensed at this time will be removed from the air by auto drain and drained out automatically. Air separated from the water will be heated by a cooler re-heater (heat exchanger) to obtain the dried air, which goes through to the outlet side.

IDFA3E

Drain separator

Compressed air inlet

Cooler

Compressed air outlet

Re-heater

Drain outlet

Volume control valve

Condenser

Fan motor

Pressure switch

Capillary tube

Compressor for refrigeration

Evaporation thermometer

IDFA4E, IDFA6E

IDFA8E, IDFA11E, IDFA15E

Compressed air inlet

Compressed air outlet

Heat exchanger

Drain separator

Volume control valve

Evaporation thermometer

Drain outlet

Capillary tube

Compressor for refrigeration

Pressure switch

Condenser

Fan motor

4

IDFAE-B.qxd 07.6.26 4:57 PM Page 6

Series

IDFA 쏔 E

Dimensions

IDFA3E to 15E

A

A

Q

B

In case of IDFA3E

P

L

K

4 x ø13

N

M

IDFA4E to 15E

Dimensions

Model

IDFA3E

IDFA4E

IDFA6E

Port size

Rc 3/8

Rc 1/2

A

226

B

410

453

C

473

498

IDFA8E

IDFA11E

Rc 3/4

270

455

485 568

IDFA15E Rc 1 300 603 578

Meaning the foot dimensions for the IDFA3E.

D

67

31

41

E

125

F

304

283

42

54

355

396

G

33

80

87

K

36

15

L

154

M

21

N

330

275

P

240 80

43 101

300

380 314

(mm)

Q

15

13

15

16

E D

5

IDFAE-B.qxd 07.6.26 4:57 PM Page 7

Refrigerant R407C (HFC)

Series

IDFA

22E, 37E, 55E, 75E

(Inlet air temperature: 35

°

C)

쏔 E

How to Order

IDFA 55 E

Size

Size

22

37

55

75

23

Note 1)

T

V

L

R

Nil

A

C

K

Symbol

23

Voltage

Voltage

Single-phase

230 VAC (50 Hz)

Options and Available Combinations (Size/Option)

Size

Symbol Note 2)

22

37

55

75

Option

Nil

None

A

Cool compressed air output

C

Anticorrosive treatment

K

For medium air pressure

Auto drain bowl type:

Metal bowl with level gauge

L

With heavy duty auto drain

(Applicable to medium air pressure)

R

With circuit breaker

T

With terminal block for run & alarm signal

V

With timer-type solenoid valve

(Applicable to medium air pressure)

Note 1) G thread (PF thread) can accept the R thread (PT male thread), thus making no “F” in the thread specification setting.

Note 2) Enter alphabetically when multiple options are combined.

However, the following combination cannot be achieved.

• Combination of K, L and V cannot be achieved because an auto drain can only be attached to a single option.

Note 3) Refer to page 9 for further details on optional specifications.

6

IDFAE-B.qxd 07.6.26 4:57 PM Page 8

Series

IDFA 쏔 E

Standard Specifications

JIS Symbol

Refrigerated air dryer

Auto drain

Model

Specifications

Fluid

Inlet air temperature

Inlet air pressure (MPa)

Ambient temperature (Humidity)

Air flow capacity m 3 /h

Note 1)

Standard condition

(ANR)

Com-

Note 2) pressor intake condition

Outlet air pressure dew point

Outlet air pressure dew point

Outlet air pressure dew point

Outlet air pressure dew point

Outlet air pressure dew point

Outlet air pressure dew point

(

°

C)

(3

°

C)

(7

°

C)

(10

°

C)

(3

°

C)

(7

°

C)

(10

°

C)

Inlet air pressure

(

°

C)

Inlet air temperature

Ambient temperature

(MPa)

(

°

C)

(

°

C)

Power supply voltage

Power consumption

Operating current

Applicable circuit breaker capacity Note 4)

Condenser

Refrigerant

(W)

(A)

(A)

Standard temperature air inlet

IDFA22E IDFA37E IDFA55E

Compressed air

IDFA75E

5 to 50

0.15 to 1.0

2 to 40 (Relative humidity of 85% or less)

182

231

273

347

390

432

660

720

254

189

240

264

382

284

361

397

510

405

449

530

822

686

748

854

0.7

35

25

Single-phase: 230 VAC [Voltage fluctuation

±

10%] 50 Hz

760 1130 1700

4.3

10

Air-cooled

5.4

7.9

20

R407C (HFC)

Auto drain

Port size

Accessory

Weight

Coating color

(kg)

R 1

54

Float type

(Normally open)

R 1 1 /

2

62 100

Body panel: White 1

Base: Gray 2

R 2

116

Compliant standards EC Directive (with CE marking)

Note 1) Air flow capacity under the standard condition (ANR) [atmospheric pressure at 20

°

C, relative humidity at

65%]

Note 2) Air flow capacity converted by the compressor intake condition [atmospheric pressure at 32

°

C]

Note 3) Select air dryer according to the model selection method (page 2) for the models beyond the rated specifications.

Note 4) Install a circuit breaker with a sensitivity of 30 mA.

Note 5) When a short-term interruption of the power supply (including momentary interruption) occurs in this equipment, the restarting of normal operations may require some time or may be impossible due to the operation of protective devices even after the supply of power returns.

Replacement Parts

Model

Auto drain replacement parts no. Note 5)

IDFA22E IDFA37E IDFA55E IDFA75E

AD48

Note 6) The part number for the auto drain components without including the body part.

Body part replacement is impossible.

Body

Auto drain

Construction (Air/Refrigerant Circuit)

Humid, hot air coming into the air dryer will be cooled down by a cooler re-heater

(heat exchanger). Water condensed at this time will be removed from the air by auto drain and drained out automatically. Air separated from the water will be heated by a cooler re-heater (heat exchanger) to obtain the dried air, which goes through to the outlet side.

IDFA22E, IDFA37E, IDFA55E, IDFA75E

Evaporation thermometer

Compressed air inlet

Volume control valve

Accumulator

(IDFA22E, 37E, 55E only)

Condenser

Compressed air outlet

Cooler re-heater

(Heat exchanger)

Ball valve

Auto drain

Drain outlet

Capillary tube

Pressure switch

Compressor for refrigeration

High pressure switch

(IDFA55E, 75E only)

Fan motor

7

IDFAE-B.qxd 07.6.26 4:57 PM Page 9

Dimensions

IDFA22E

,

IDFA37E

B

E

D

G

A

Refrigerated Air Dryer

Series

IDFA 쏔 E

M

N

P

L

K

4 x ø13

Dimensions

Model

IDFA22E

IDFA37E

Port size

R 1

R 1

1

/

2

A

290

B

775

855

C D E F

623 134 405 698

G

93

K

13

L

25

M

85

N

600

680

P

340

(mm)

Q

IDFA55E

,

IDFA75E

B

R

E

A

Q

D

G

M

N

P

L

K

4 x ø13

Dimensions

Model

IDFA55E

IDFA75E

Port size

R 2

A B

470 855

C

800

900

D E

(128) (273)

F

(868)

(968)

G K

(110) 13

L

500

M

75

N P Q

(mm)

R

700 526 (110) 519

8

IDFAE-B.qxd 07.6.26 4:57 PM Page 10

9

Series

IDFA 쏔 E

Options 1

A

Option symbol

Cool compressed air output IDFA3E to 11E

There is no heating of cooled, dehumidified air as it leaves the air dryer.

The air flow capacity with this option is smaller than that of the standard dryer. (The external dimensions are identical with the standard product.)

Note) Perform thermal insulation treatment for piping and equipment installed after the dryer to prevent the formation of condensation.

Air Flow Capacity

Model IDFA3E IDFA4E IDFA6E IDFA8E

Air flow capacity m

3

/h (ANR) 18 23 29 32

Conditions: Inlet air pressure: 0.7 MPa, Inlet air temperature: 35 ° C ,

Outlet air temperature: 10 ° C Ambient temperature: 25 ° C

IDFA11E

39

For “How to Order” optional models, refer to page 3 and 6.

L

Option symbol

With heavy duty auto drain

(Applicable to medium air pressure)

IDFA4E to 75E

The float type auto drain used in the standard air dryer is replaced with a heavy duty auto drain (ADH4000-04) which enables the drainage to discharge more efficiently.

IDFA4E to 15E

Dimensions

Model

IDFA4E

IDFA6E

IDFA8E, 11E

IDFA15E

A

55

(mm)

67

139

47

(207)

(157)

C Option symbol

Anti-corrosive treatment IDFA all models

This minimizes the corrosion of the copper and copper alloy parts when the air dryer is used in an atmosphere containing hydrogen sulfide or sulfurous acid gas. (Corrosion cannot be completely prevented.)

Special epoxy coating: Copper tube and copper alloy parts.

The coating is not applied on the heat exchanger or around electrical parts, where operation may be affected by the coating.

Corrosion is not covered under warranty.

Drain outlet

Rc 1/2

Ball valve

Heavy duty auto drain

IDFA22E to 75E

K

Option symbol

For medium air pressure

Auto drain bowl type:

Metal bowl with level gauge

IDFA6E to 37E

The auto drain is changed from the standard one to one with a medium pressure specification.

A metal bowl with a level gauge which can confirm the water level is used for the auto drain.

Specifications

1. Maximum operating pressure: 1.6 MPa

2. Dimensions ··· same as standard products

Replacement Parts

Model

Auto drain assembly part no.

IDFA6E to 15E

IDFA22E, 37E

Note

IDF-S0086

AD48-8-X2110

The AD48-8-X2110 auto drain, insulator, and one-touch fitting are included.

Single auto drain unit

Ball valve

Drain tube:

Length approx.

0.95 m

(O.D. ø10)

Heavy duty auto drain

Dimensions

Model

IDFA22E, 37E

IDFA55E, 75E

(mm)

A

Approx. 100

Approx. 50

Note 1) The heavy duty auto drain and the ball valve are both enclosed in the same shipping package as the main body of the air dryer. Customers are required to mount the parts to the air dryer. (Except IDFA22E to 75E)

Note 2) Customers will need to supply the fitting and tubing for the drain piping.

(Except IDFA22E to 75E)

Replacement Parts: Heavy Duty Auto Drain

Model

Replacement parts no.

(Description)

Configuration

Heavy duty auto drain

IDFA4E to 15E

ADH4000-04

(Heavy duty auto drain)

Replacement kit for exhaust mechanism

IDFA22E to 75E

ADH-E400

(Replacement kit for exhaust mechanism)

Housing

(You don’t need to purchase a new housing.)

IDFAE-B.qxd 07.6.26 4:57 PM Page 11

Series

IDFA 쏔 E

Options 2

R

Option symbol

With circuit breaker IDFA4E to 75E

A circuit breaker with cover is attached to the side of the air dryer. This saves additional electrical wiring at the time of installation.

IDFA4E to 15E

E

Dimensions

Model

IDFA4E, 6E, 8E, 11E

IDFA15E

A

32

43

D

40

Circuit breaker

B

230

258

B

Power cable outlet (ø17)

Grommet with membrane

C

97

102

D

34

82

(mm)

E

15

For “How to Order” optional models, refer to page 3 and 6.

T

Option symbol

With terminal block for power supply, run & alarm signal and remote operation

IDFA4E to 75E

In addition to the terminals for the power supply, terminals for the operating signal and the error signal are also available. (No-voltage contact)

Also, in the case of remote control, operate it from the power supply side while the air dryer switch remains ON.

Contact capacity: 230 VAC, 4 A 24 VDC, 5 A for operating and error signals.

Minimum current value: 20 V, 5 mA (AC/DC) for operating and error signals.

Note) Please be sure to confirm the electric circuits with the drawings or instruction manual before using the output signal.

IDFA4E to 15E

Terminal block

Signal cable outlet (ø17)

Grommet with membrane

IDFA22E to 75E

B

D

Dimensions

Model

IDFA4E, 6E, 8E, 11E

IDFA15E

Power cable outlet (ø17)

Grommet with membrane

A

32

43

B

230

258

C

67

77 Circuit breaker

D

179

(mm)

158

B D

IDFA22E to 75E

Power cable outlet (ø17)

(Wire diameter ø9 to 11)

F

Dimensions

Model

IDFA22E

IDFA37E

IDFA55E

IDFA75E

A

125

148

133

B

59

39

81

73

C

60

D

40

60

E

25

50

(mm)

E

46

36

Breaker Capacity and Sensitivity Current

Voltage Model

Breaker capacity

230 V type

IDFA4E-23, IDFA6E-23

IDFA8E-23, IDFA11E-23

IDFA15E-23, IDFA22E-23

IDFA37E-23, IDFA55E-23

IDFA75E-23

5 A

10 A

20 A

Sensitivity current

30 mA

Power cable outlet (ø17)

(Wire diameter ø9 to 11)

Dimensions

Model

IDFA22E, 37E

IDFA55E, 75E

B

D

A

25

50

Signal cable outlet

(Wire diameter ø17)

Grommet with membrane

B

46

36

C

135

207

Terminal block

D

81

(mm)

81

V

Option symbol

With timer-type solenoid valve

(Applicable to medium air pressure)

IDFA4E to 75E

Drainage is discharged by controlling a solenoid valve with a timer.

A strainer for solenoid valve protection and stop valve are also included.

Maximum operating pressure: 1.6 MPa

The timer-type solenoid valve actuates once (for 0.5 s) every 30 s.

Replacement Parts

Model

IDFA4E to 75E

Part no.

IDF-S0198

Note

230 VAC

10

IDFAE-B.qxd 07.6.26 4:57 PM Page 12

Dust-protecting filter set

Foundation bolt set

Optional Accessories

Features

Prevents a decline in the performance of the air dryer, even in a dusty atmosphere.

Bolts for fixing the air dryer to the foundations.

Easy to secure by striking its axle.

Specifications

Max. ambient temperature

40

°

C

Stainless steel

Applicable dryer

IDFA3E to 75E

IDFA4E to 75E

How to Order

Dust-protecting filter set

IDF FL 209

Applicable dryer

Symbol

209

202

203

204

205

206

207

208

213

214

Applicable dryer

IDFA3E

IDFA4E

IDFA6E

IDFA8E

IDFA11E

IDFA15E

IDFA22E

IDFA37E

IDFA55E

IDFA75E

Foundation bolt set

IDF AB 500

Dust-protecting Filter Set / Dimensions

Applicable dryer

Symbol Applicable dryer

500 IDFA4E to 75E

(20)

A

(20)

Dimensions

Part no.

Applicable dryer

IDF-FL209

IDF-FL202

IDF-FL203

IDF-FL204

IDF-FL205

IDF-FL206

IDF-FL207

IDF-FL208

IDF-FL213

IDF-FL214

IDFA3E

IDFA4E

IDFA6E

IDFA8E

IDFA11E

IDFA15E

IDFA22E

IDFA37E

IDFA55E

IDFA75E

A

220

310

375

340

375

310

420

550

720

610

(IDF-FL209) (IDF-FL202 to 208, 213, 214)

Foundation Bolt Set / Dimensions

Dimensions

(mm)

Part no.

IDF-AB500

Applicable dryer

IDFA4E to 75E

Nominal thread size

M10

Material

Stainless steel

(mm)

Pcs. of

1 set

4

11

Mounting hole diameter: ø10.5

IDFAE-B.qxd 07.6.26 4:57 PM Page 13

Data

Condensed Water Calculation

Relative humidity

100

%

80

%

60

%

40

%

20

%

B

45

40

35

30

25

20

Amount of condensed water

C

C–H

18.2 - 3.0 = 15.2 g /m 3

15

Atm ospheric pressure

0.1 M

Pa

0.2

0.3

0.4 0.5

0.6

0

.7

0.8

D

1.0

1.4

1.6

10

–20 –10 0 10 20

A

30 40 50 60

0

Ambient temperature (Air compressor intake air temperature) (

°

C)

5

H

Dew Point Conversion Chart

10

0

–10

–20

–30

–40

60

50

40

30

20

A B

–50

C

–60

–60 –50 –40 –30 –20 –10

Atmospheric pressure dew point (

°

C)

0 10

1.5 MPa

1.3 MPa

1.1 MPa

0.9 MPa

0.7 MPa

0.5 MPa

0.3 MPa

0.1 MPa

Atmospheric pressure

20 30

How to read the dew point conversion chart

Example) To obtain the atmospheric dew point at a pressure dew point of

10

°

C, and a pressure of 0.7 MPa.

1. Trace the arrow mark from point A at a pressure dew point of 10

°

C to obtain the intersection B on the pressure characteristic line for

0.7 MPa.

2. Trace the arrow mark from point B to obtain the intersection C on the atmospheric pressure dew point.

3. The intersection C is the conversion value –17

°

C under atmospheric pressure dew point.

0

G

20

F

10 30 40

Pressure dew point (

°

C)

50 60

E

70 80

How to calculate the amount of condensed water

Example) To obtain the amount of condensed water when the inlet air of a compressor is pressurized to 0.7 MPa then cooled down to 25

°

C.

Given an ambient temperature of 30

°

C and a relative humidity of 60%.

1. Trace the arrow mark from point A of ambient temperature 30

°

C to obtain the intersection B on the curved line for the relative humidity of 60%.

2. Trace the arrow mark from the intersection B to obtain the intersection D on the curved line for the

0.7 MPa pressure characteristics.

3. Trace the intersection D to obtain the intersection

E.

4. The intersection E is the pressure dew point at 0.7

MPa with an ambient temperature of 30

°

C and a relative humidity of 60%. The value for E is at

62

°

C.

5. Trace the intersection E upward to D and leftward to obtain the intersection C on the vertical line.

6. The intersection C is the amount of water which is included in the compressed air 1 m 3 at 0.7 MPa, a pressure dew point of 62

°

C. The amount of water is 18.2 g/m 3 .

7. Trace the arrow mark from F (cooling temperature

25

°

C (pressure dew point 25

°

C)) to obtain the intersection G on the pressure characteristic line for

0.7 MPa.

8. From the intersection G, trace the arrow mark to obtain the intersection H on the vertical line.

9. The intersection H is the amount of water which is included in the compressed air 1 m 3 at 0.7 MPa, pressure dew point of 25

°

C. The amount of water is 3.0 g/m 3 .

10. Therefore, the amount of condensed water is as following. (per 1 m 3 )

The amount of water at the intersection C

– the amount of water at the intersection H

= the amount of condensed water

18.2 – 3.0 = 15.2 g/m 3

12

IDFAE-B.qxd 07.6.26 4:57 PM Page 14

Series

IDFA

E

Safety Instructions

These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 Note 1) , JIS B 8370 Note 2) and other safety practices.

Explanation of the Labels

Labels Explanation of the labels

Danger

In extreme conditions, there is a possible result of serious injury or loss of life.

Warning

Operator error could result in serious injury or loss of life.

Caution

Operator error could result in injury Note 3) or equipment damage.

Note 4)

Note 1) ISO 4414: Pneumatic fluid power – General rules relating to systems

Note 2) JIS B 8370: General Rules for Pneumatic Equipment

Note 3) Injury indicates light wounds, burns and electrical shocks that do not require hospitalization or hospital visits for long-term medical treatment.

Note 4) Equipment damage refers to extensive damage to the equipment and surrounding devices.

Selection/Handling/Applications

1. The compatibility of the pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications.

Since the products specified here are used in various operating conditions, their compatibility for the specific pneumatic system must be based on specifications or post analysis and/or tests to meet the specific requirements. The expected performance and safety assurance are the responsibility of the person who has determined the compatibility of the system. This person should continuously review the suitability of all items specified, referring to the latest catalog information with a view to giving due consideration to any possibility of equipment failure when configuring a system.

2. Only trained personnel should operate pneumatically operated machinery and equipment.

Compressed air can be dangerous if handled incorrectly. Assembly, handling or repair of the systems using pneumatic equipment should be performed by trained and experienced operators. (Understanding JIS B 8370 General Rules for Pneumatic Equipment, and other safety rules are included.)

3. Do not service machinery/equipment or attempt to remove components until safety is confirmed.

1. Inspection and maintenance of machinery/equipment should only be performed once measures to prevent falling or runaway of the driven objects have been confirmed.

2. When equipment is removed, confirm the safety process as mentioned above. Turn off the supply pressure for this equipment and exhaust all residual compressed air in the system, and release all the energy (liquid pressure, spring, condenser, gravity).

3. Before machinery/equipment is restarted, take measures to prevent quick extension of a cylinder piston rod, etc.

4. If the equipment will be used in the following conditions or environment, please contact SMC first and be sure to take all necessary safety precautions.

1. Conditions and environments beyond the given specifications, or if product is used outdoors.

2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and brake circuits in press applications, or safety equipment.

3. An application which has the possibility of having negative effects on people, property, requiring special safety analysis.

4. If the products are used in an interlock circuit, prepare a double interlock style circuit with a mechanical protection function for the prevention of a breakdown. And, examine the devices periodically if they function normally or not.

Exemption from Liability

1. SMC, its officers and employees shall be exempted from liability for any loss or damage arising out of earthquakes or fire, action by a third person, accidents, customer error with or without intention, product misuse, and any other damages caused by abnormal operating conditions.

2. SMC, its officers and employees shall be exempted from liability for any direct or indirect loss or damage, including consequential loss or damage, loss of profits, or loss of chance, claims, demands, proceedings, costs, expenses, awards, judgments and any other liability whatsoever including legal costs and expenses, which may be suffered or incurred, whether in tort (including negligence), contract, breach of statutory duty, equity or otherwise.

3. SMC is exempted from liability for any damages caused by operations not contained in the catalogs and/or instruction manuals, and operations outside of the specification range.

4. SMC is exempted from liability for any loss or damage whatsoever caused by malfunctions of its products when combined with other devices or software.

Back page 1

IDFAE-B.qxd 07.6.26 4:57 PM Page 15

Series

IDFA 쏔 E

Specific Product Precautions 1

Be sure to read this before handling. For Air Preparation Equipment Precautions, refer to “Precautions for Handling Pneumatic Devices” (M-03-E3A).

Installation

Caution

• Avoid locations where the air dryer will be in direct contact with wind and rain. (Places where relative humidity is greater than

85%)

• Avoid exposure to direct sunlight.

• Avoid locations that contain much dust, corrosive gases, or flammable gases. Failure due to corrosion is not covered under warranty. However, when the risk of corrosion is high, select

“Option C” (copper tubing with anti-corrosive treatment).

• Avoid locations of poor ventilation and high temperature.

• Too close to a wall etc. Leave sufficient room between the dryer and the wall according to the “Maintenance space” in the operation manual.

• Avoid locations where a dryer could draw in high temperature air that is discharged from an air compressor or other dryer.

Air Piping

Caution

• Be careful to avoid an error in connecting the air piping at the compressed air inlet (IN) and outlet (OUT).

• Install by-pass piping since it is needed for maintenance.

IDFA3E

Compressed air inlet Compressed air outlet

Valve closed

Valve open

IDFA4E to 15E

The air exhaust should not flow into the neighboring equipment. (Top side)

• Avoid locations subjected to vibration.

• Avoid possible locations where the drain can freeze.

• Use the air dryer with an ambient temperature lower than 40

°

C.

• Avoid installation on machines for transporting, such as trucks, ships, etc.

Compressed air inlet Compressed air outlet

Valve closed

Valve open

Drain Tube

Caution

• A polyurethane tube is attached as a drain tube for the IDFA3E to 37E. Use this tube to discharge drainage.

• Do not use the drain tube in an upward direction. Do not bend or crush the drain tube. (Operation of the auto drain will stop water vapor from discharging through the air outlet.)

IDFA22E, 37E

Power Supply

Caution

• Connect the power supply to the terminal block.

• Install a suitable circuit breaker applicable for the specific model.

• The voltage fluctuation should be maintained within

±

10% of the rated voltage.

Compressed air outlet Compressed air inlet

Valve closed

Valve open

Back page 2

IDFAE-B.qxd 07.6.26 4:57 PM Page 16

Series

IDFA 쏔 E

Specific Product Precautions 2

Be sure to read this before handling. For Air Preparation Equipment Precautions, refer to “Precautions for Handling Pneumatic Devices” (M-03-E3A).

Air Piping

Caution

IDFA55E, 75E

Compressed air outlet Compressed air inlet

Auto Drain

Caution

The auto drain may not function properly, depending on the quality of the compressed air. Check the operation once a day.

Valve closed

Valve open

Cleaning of Ventilation Area

Caution

Remove dust from the ventilation area once a month using a vacuum cleaner or an air blow nozzle.

• When tightening piping at the air inlet/outlet tube, the hexagonal parts of the port on the air dryer side or piping should be held firmly with a spanner or adjustable angle wrench.

• Variations in operating conditions may cause condensation to form at the surface of the outlet piping. Apply thermal insulation around the piping to prevent condensation from forming.

• Vibration resulting from the compressor should not be transmitted through air piping to the air dryer.

• Do not allow the weight of the piping to lie directly on the air dryer.

Time Delay for Restarting

Caution

Allow at least three minutes before restarting the dryer. If the air dryer is restarted within three minutes after being stopped, the protection circuit will be activated, operating light turns off and the dryer will not be activated.

Protection Circuit

Caution

When the air dryer is operated under the following stated conditions, a protection circuit is activated, the light turns off and operation stops.

• When the compressed air temperature is too high.

• When the compressed air flow rate is too high.

• When the ambient temperature is too high. (40

°

C or higher)

• When the fluctuation of the power supply is beyond the rated voltage

±

10%.

• When the dryer is drawing in high temperature air that is discharged from an air compressor or other dryer.

• The ventilation port is obstructed by a wall or clogged with dust.

Compressor Air Delivery

Caution

Use an air compressor with an air delivery of 100 l /min or larger with the IDFA3E to 75E series.

Since the auto drain of the IDFA3E to 75E is designed in such a way that the valve remains open unless the air pressure rises to

0.15 MPa or higher, air will blow out from the drain discharge port at the time of air compressor start-up until the pressure increases. Therefore, if an air compressor has a small air delivery, the pressure may not be sufficient.

Back page 3

IDFAE-B.qxd 07.6.26 4:57 PM Page 17

Air Dryers for Japan Use

Complies with CFC restrictions

Refrigerated Air Dryer

Series

IDF

Standard temperature air inlet type

Rated inlet air temperature:

35, 40

°

C Model

IDF1E

IDF2E

IDF3E

IDF4E

IDF6E

IDF8E

IDF11E

IDF15E

IDF22E

IDF37E

IDF55E

IDF75E

IDF120D

IDF150D

IDF190D

IDF240D

Rated inlet condition

Air flow capacity (m 3 /min [ANR])

50 Hz 60 Hz

0.1

0.12

35

°

C

0.7 MPa

40

°

C

0.7 MPa

0.2

0.32

0.52

0.75

1.22

1.65

2.8

3.9

5.7

8.4

11.0

20.0

25.0

32.0

43.0

0.235

0.37

0.57

0.82

1.32

1.82

3.1

4.3

6.1

9.8

12.4

23.0

30.0

38.0

50.0

IDF370B

35

°

C

0.7 MPa

54.0 65.0

Applicable air compressor (kW)

370

22

37

55

75

120

150

190

240

0.75

1.5

2.2

3.7

5.5

7.5

11

15

Refrigerant

R134a (HFC)

R407C (HFC)

R22

Port size

Rc 3/8

Rc 1/2

Rc 3/4

Rc 1

R 1

R 1 1 /

2

R 2

2 1 /

2

B flange

3B flange

4B flange

6B flange

Complies with CFC restrictions

Refrigerated Air Dryer

Series

IDU

High temperature air inlet type

Rated inlet air temperature:

50, 55

°

C Model

IDU3E

IDU4E

IDU6E

IDU8E

IDU11E

IDU15E

IDU22E

IDU37E

IDU55C

IDU75C

Rated inlet condition

Air flow capacity (m 3 /min [ANR])

50 Hz 60 Hz

0.32

0.37

0.52

0.57

55

°

C

0.7 MPa

0.75

1.1

1.5

2.6

0.82

1.2

1.7

2.8

50

°

C

0.7 MPa

3.9

5.7

7.65

10.5

4.3

6.1

9.0

12.4

Applicable air compressor (kW)

2.2

3.7

5.5

7.5

11

15

22

37

55

75

Refrigerant

R134a (HFC)

R407C (HFC)

R22

Port size

Rc 3/8

Rc 1/2

Rc 3/4

Rc 1

R 1

R 1 1 /

2

R 2

See separate catalog.

Back page 4

IDFAE-B.qxd 07.6.26 4:57 PM Page 18

Air Dryers Compliant to

Overseas Standards

Refrigerated Air Dryer

Series

IDFB 쏔 E

UL certified

Power supply voltage:

Single-phase 115 VAC (60 Hz)

230 VAC (60 Hz)

Refrigerant: R134a (HFC)

Coefficient of destruction for ozone is zero.

Improved corrosion resistance with the use of stainless steel, plate type heat exchanger

(IDFB4E to 37E)

Back page 5

Series

IDFB3E

IDFB4E

IDFB6E

IDFB8E

IDFB11E

IDFB15E

IDFB22E

IDFB37E

Air flow capacity SCFM (m

3

/h [ANR])

37

°

F (2.8

10 (17)

°

Outlet air pressure dew point

C) 45

°

F (7.2

°

C)

11 (19)

50

°

F (10

°

12 (20)

C)

15 (25)

25 (43)

41 (70)

59 (100)

16 (27)

26 (45)

43 (74)

62 (106)

17 (28)

28 (47)

45 (77)

65 (110)

71 (120)

107 (182)

161 (273)

80 (136)

120 (205)

173 (294)

86 (147)

130 (221)

181 (308)

Refrigerant

Rated inlet condition

Port size

NPT 3/8

NPT 1/2

R134a (HFC)

100

°

F

(37.8

°

C)

100 psig

(0.7 MPa)

NPT 3/4

NPT 1

NPT 1 1 /

2

See separate catalog for dryer models conforming with North American standards (UL).

IDFAE-B.qxd 07.6.26 4:57 PM Page 19

Related Products

Membrane Air Dryer

Series

IDG

Dew point indicator for checking air drying condition at a glance

(Except IDG1)

(The IDG3, IDG5, IDG3H, IDG5H are semistandard.)

• Compact

• Lightweight

• Space-saving

Fitting for discharging purge air available

Purge air can be discharged with a tube if it should not be discharged around the membrane air dryer (semi-standard).

Discharged air noise reduced with built-in silencer

Except IDG1, IDG3, IDG3H, IDG5,

IDG5H, IDG30, IDG30H, IDG30L,

IDG50, IDG50H, IDG50L

CFC free:

Environmentally friendly

No need for a power supply

A power supply is not necessary at all.

Saves time and effort for wiring, and there is no need to consider electrical standards.

No vibration nor heat discharge

No mechanically moving parts such as refrigerator

Suitable for a low dew point

Outlet air atmospheric pressure dew point: –40˚C

IDG30L, IDG50L, IDG60L

IDG75L, IDG100L

Outlet air atmospheric pressure dew point: –60˚C

IDG60S, IDG75S, IDG100S

Outlet air flow rate

10 to 1000

l

/min (ANR)

Heatless Air Dryer

Series

ID

Heatless type ID series is ideal for applications that require dry air with a low dew point.

Supplies dry air with a low dew condensation point of

–30

°

C or less.

Small and light without heater and electric control panel

Possible to check outlet dew point with indicator

(Self-regenerative style allows easy maintenance.)

Outlet air flow rate

80 to 780

l

/min (ANR)

Back page 6

IDFAE-B.qxd 07.6.26 4:57 PM Page 20

B edition

Record of changes

Addition of Refrigerated Air Dryer, IDFA55E, 75E.

Options on page 3 and 6: Addition of “with timer-type solenoid valve”.

Number of pages 16 to 20.

Safety Instructions Be sure to read “Precautions for Handling Pneumatic Devices” (M-03-E3A) before using.

LT

Akihabara UDX 15F,

4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN

Phone: 03-5207-8249 FAX: 03-5298-5362

URL http://www.smcworld.com

© 2007 SMC Corporation All Rights Reserved

Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.

D-DN 1st printing KX printing LT 13500DN Printed in Japan.

This catalog is printed on recycled paper with concern for the global environment.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement