ZW2IR installation

ZW2IR

(Z-Wave-to-AC IR Extender)

Firmware Version: V06

1

Table of Contents

Introduction .................................................... 3

Controller and Gateway Requirements ............ 4

Built-in IR code library .................................... 4

Glossary .......................................................... 5

ZW2IR Oper ations ........................................ 6

Product Overview ............................................. 7

Z-Wave Remote Control ................................... 8

ZW2IR Inform ation ....................................... 9

Listening Mode Change .................................... 11

IR Code Selection ............................................ 11

IR Code Learning ............................................ 13

Reset ZW2IR to fa ctory default........................ 16

INSTALLATION ................................................ 17

MOUNTING THE ZW2 IR TO A WALL.................. 17

WIRELESS INFORMATION ............................... 20

MAINTENANCE................................................. 20

FREQUENTLY ASKED QUESTIONS .................... 20

Z-Wave Frequently Asked Questions ................... 20

TECHNICAL SPECIFICATIONS.......................... 22

CHECKING ACCESSORIES ................................ 27

FCC NOTICE .................................................... 27

WARNINGS...................................................... 27

CAUTION ........................................................ 27

2

 

Introduction 

Z-Extender

TM

ZW2IR

(Z-Wave-to-AC IR Extender)

Operating Instructions

The  ZW2 IR  is a Z‐Wave to IR extender for air‐conditioner (AC), 

(Figure 1), it works with any Z‐Wave compliant gateway or controller  by translating Z‐Wave Thermostat Commands to AC IR control code. 

User can select the IR code from the built‐in code library of  ‐ IR, or use learning function, by using Z‐Wave Configuration Commands 

  according to the parameter table.   ‐ IR  is also with built‐in  temperature sensor which allows gateway or controller to get the  current room temperature.  

Figure 1 ZW2IR

 

 

‐ IR  can be configured as either “Frequently Listening Routing 

Slaves” (FLiRS) or “Always Listening” node after exclusion process 

 

(before inclusion process).  

FLiRS node type is for battery operated applications and it will enter  sleep mode frequently in order to conserve battery consumption that  can provide the flexibility if there is out of 5Vdc power source. Also, 

  user can place the unit in anywhere at home.  

Always Listening node type is for the needs of fast response  application. It works with 5Vdc power source. Always Listening node  can act as a repeater, which will re‐transmit the RF signal to ensure  that the signal is received by its intended destination by routing the 

  signal around obstacle and radio dead spots. 

‐ IR  supports Network Wide Inclusion (NWI) and Explore Frames. 

It also supports Z‐Wave networks with multiple gateways and  controllers. Like every Z‐Wave accessory, user will need to include the 

3

‐ IR  into their Z‐Wave network using the primary controller. Then,  the user can use either the primary controller or secondary controller  to configure and setup the  ‐ IR  using Z‐Wave’s configuration  command class. Once the configuration and setup is complete, the 

  controller can use Z‐Wave “Thermostat commands class” to control  their IR‐controlled air‐conditioner through the  ‐ IR.

  

 

Controller and Gateway Requirements 

The  ‐ IR  can work with any Z‐Wave compliant controller or  gateway supporting the following Z‐Wave commands. 

- Configuration Command Class 

- Multilevel Sensor Command Class 

- Thermostat Command Class  

ƒ Thermostat Mode Command Class 

ƒ Thermostat Fan Mode Command Class 

ƒ Thermostat Set‐point Command Class 

Built‐in IR code library 

The Built‐in IR code library supports most of the popular air 

 

conditioner brands in the market. Z‐Wave gateway and controller  does not need to have any IR control code knowledge. User can use Z‐

Wave controller or gateway to select the IR code according to the  ZW2

IR  code list separately provided through Z‐Wave configuration  command.  

4

Glossary 

Device or 

Node 

Inclusion 

Exclusion 

Remove 

Z‐Wave 

Network  

Primary 

Controller 

Secondary 

Controller 

Inclusion 

Controller 

Devices and nodes are all terms to describe an  individual Z‐Wave device. These are all  interchangeable when setting up your Z‐Wave  network.

Add a Z‐Wave device to the network.  

Delete a Z‐Wave device from the network.  

To take a device out of a group, scene or  association group while that device still exists  in the same Z‐Wave network. 

A collection of Z‐Wave devices is controlled by  primary and secondary controllers operating  on the same system. A Z‐Wave network has its  own unique ID code so that controllers not in  the network cannot control the system.  

The first controller is used to set up your  devices and network. Only the Primary 

Controller can be used to include or delete  devices from a network. It is recommended  that you mark the primary controller for each  network for ease in modifying your network.  

A controller containing network information  about other devices within the network and is  used for controlling devices. Secondary  controller is created from the Primary 

Controller and cannot include or delete devices  to the network.  

A controller containing network information  about other devices within the network and is  used for controlling devices. Inclusion  controller is created from the Primary 

Controller in a SIS enabled Z‐Wave network. 

Inclusion Controllers have the ability to add  and remove devices from the network.  

5

 

ZW2‐IR  Operations 

Before using the ZW2‐IR,  please read the [INSTALLATION] if you need  to mount the ZW2‐IR  to a wall. Power up the ZW2‐IR  by the USB 

Power 5Vdc or Dry battery AAA x 3pcs. 

 

• Plug‐in 5Vdc power into the USB socket if operated at Always 

Listening mode. Or 

• Install 3xAAA batteries if operated at FLiRS mode.  

• Please refer to the section of [MOUNTING PROCEDURE]. 

• Remove the battery cover on the back of your ZW2‐IR  battery  chassis. 

• Mount the battery cover into the main unit with 2 screws. 

• Check the polarity of the batteries and the "+/‐" marks inside the 

  battery compartment. 

• Insert the batteries.

 

• Push the battery cover and main unit back in place. 

L CAUTION (battery and power adaptor safety) 

− Use new batteries of the recommended type and size only. 

− Never mix used and new batteries together. 

− To avoid chemical leaks, remove batteries from the ZW2‐IR  if  you do not intend to use the remote for an extended period  of time. 

− Dispose of used batteries properly; do not burn or bury them.

 

(Please carefully read through the following then store the manual for 

  future reference.) 

6

 

 

 

 

 

 

 

 

 

Product Overview 

“PROG” Button,

Learning and LED

Indication

Temperature sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

External

IR Port top and 4-directions

USB Power

Surround IR Output for

 

 

5V DC

Figure 2 PROG Key and IR Port of ZXT-120

7

Battery chassis

 

 

Z‐Wave Remote Control 

1) Select your operation mode; please refer to “Listening Mode”  section. 

2) Include or Exclude the unit from the existing Z‐Wave home  control network with your primary controller. 

‐  Refer to your primary controller instructions to process  the inclusion / exclusion setup procedure. 

‐ 

‐ 

When prompted by your primary controller, click once  on the PROG button. 

The primary controller should indicate that the action  was successful. If the controller indicates the action was  unsuccessful, please repeat the procedure. 

3) User can use either   primary controller or secondary controller 

(should support configuration command class) to setup the ZW2‐

IR  AC code by the parameter 27 (IR code number for built‐in  code library), please refer to code list for the parameter value  then setup your AC control code. 

4) Once the configuration and setup were completed, the  controller can use Z‐Wave “Thermostat commands class” to  control their IR‐controlled air‐conditioner with the ZW2‐IR.   

 

5) You can record down your device code under the below table for  future reference after setting up the ZW2‐IR  correctly. 

AC device programmed to your ZW2‐IR  

Code no.:  

8

 

ZW2  

 

How to get the NIF “Node Information Frame” on ZW2‐IR   (Inclusion) 

Step  Setup Key 

Press the PROG button on the 

ZW2‐IR  

LED Indication Status  on ZW2‐IR  

• LED flashes once  then stay off 

 

  (ZW2‐IR  will report  the supported  command class) 

 

Parameter No. and Parameter Value of configuration command 

Parameter 

Number 

25  

(0x19) 

26 

(0x1A) 

Definitions 

Indicate a location for IR code  learning and start learning 

 

Learning status register 

 

 

Note:  

The status value 0x01 and  

0x04 will be reset to 0 when  the ZXT‐120 receive a get  command to this parameter 

Parameter Value 

0‐22 

(0x00 – 0x16) 

0x00: Idle ‐ this IR  channel is idle 

 

(default) 

0x01: OK ‐ the latest  learning process  successful and 

  completed 

0x02: Learning ‐ the 

ZXT‐120 is busy  processing previous  learning request 

 

0x04: Failed ‐ the  latest learning  request failed 

27 

(0x1B) 

IR code number for built‐in  code library  

Refer “Code list” for  details 

28 

(0x1C) 

32  

(0x20) 

 

External IR Emitter power  level 

Surround IR control 

- to avoid the IR interference  by disabling the  surrounding IR emitter if 2 

0x00: normal power  mode 

0xFF: high power  mode (default) 

0x00: disable 

Surround IR Emitters 

0xFF: enable 

Surround IR Emitters 

9

 

33 

(0x21) 

35 

(0x23)  air‐conditioners in a room  are used 

- extend the battery life by  disabling the Surround IR 

Emitters 

(default) 

AC function “SWING” control  0x00: SWING OFF  

0x01: SWING AUTO 

Learn location status 

(Default) 

Bit mask = 1, learn  location has learn  data. Otherwise, Bit  mask = 0 

See figure “Learn 

location” as below 

Parameter Table 

7

1

6

0

5

0

4

0

3 2 1 0

0 0 1 0 Bit Mask Byte 1 

Location 0‐7

7

0

6

0

5

0

4

1

3 2 1 0

0 0 0 1

Bit Mask Byte 2

Location 8‐15

7

0

6

0

5

0

4

0

3 2 1 0

0 0 0 1

Bit Mask Byte 3

Location 16‐23

 

 

 

 

 

 

7 6 5 4 3 2 1 0

0 0 0 0 0 0 0 0

Bit Mask Byte 4

[Reseved]  

Figure: Learn location 

 

On the above example, location 1, 7, 8, 12, 16 has learned data. 

L Mapping Information 

− BASIC Set Value 0x00 will map to Thermostat mode Off 0x00. 

− BASIC set Value 0xFF will map to Thermostat mode Resume 0x05. 

10

 

Listening Mode Change (default mode is FLiRS) 

ZW2‐IR  can be configured as either “Frequently Listening Routing 

 

Slaves” (FLiRS) or “Always Listening” node after exclusion process.  

FLiRS node type is targeted for battery operated applications and it  will enter sleep mode frequently in order to conserve battery  consumption.  

 

Always Listening node type is targeted for the needs of required a fast  response application.  

 

Important:   

It is not allowed to changing ZW2‐IR  operation mode without  exclusion process (do not change ZW2‐IR  operation mode while ZXT‐

120 is included in a network). 

 

How to switch ZW2‐IR  listening mode from “Always Listening" to 

 

“FLiRS" (or vice verse)  

Step 

Setup Key 

Press and hold the PROG button on  the ZW2‐IR  for around 4 seconds 

LED Indication Status  on ZW2‐IR  

• LED stay off 

 

• LED flashes twice  then stay off 

 

 

Release the button and then press  the PROG button 3 times within 3  seconds 

(ZW2‐IR  set in FLiRS  mode) 

OR 

• LED flashes four  times then stay off

(ZW2‐IR  set in 

Always Listening  mode) 

 

 

IR Code Selection 

 

ZW2‐IR  is with built‐in IR AC code library, user may select the IR code 

  using Configuration Command Class.  

Step  Setup Key 

LED Indication Status  on ZW2‐IR  

11

 

 

 

 

After included ZW2‐IR  to Z‐Wave  controller or Gateway, go to device  setup for configuration on gateway  or controller. 

Input parameter number “27” and  parameter value (please look up the  code list of ZW2IR  according to  your AC brand). Then complete the  configuration process.   

Press the PROG button on the ZW2‐

IR.  (this step apply when using 

ZRC‐100 or other portable controller  for set up, if using gateway, user can  skip this step) 

Go back to the control page of ZW2‐

IR  on the gateway and try the  function such as (cool, temperature  set). 

 

If the air conditioner does not  respond to the command you set on 

Gateway (Cool, Heat, Auto, 

Temperature set etc.), repeat step 2  and 3 to select the next code on  code list. 

‐ 

‐ 

• LED flashes once  when ZW2‐IR   receives the  configuration  setting 

• LED flashes once  every time it  receives a  command from  gateway  

 

L Important Information 

− Different  brand  or  model  of  air  conditioner  has  different  function.  For  example,  some  air  conditioner  only  support  temperature set from 18 o

C‐30 o

C, if user set 17

 o

C on gateway, 

ZW2‐IR  will not respond.  

− There are more than 1 code for each brand, some does not  support  heat,  if  user  selected  a  code  that  does  not  support  heat  but  the  original  air  conditioner  supports  heat  function,  please  continue  to  try  next  code  until  the  correct  one  is  selected.  

− If none of the code works on the target air conditioner, or the  air  conditioner  brand  is  not  shown  on  the  code  list,  please  select code “000” for IR code learning (refer to instruction of 

IR Code Learning) 

12

 

IR Code Learning 

 

In case none of the code on the code list works for the targeted air  conditioner, user can use IR code learning function using configuration  according to below steps:  

Step 

Setup Key 

Go to configuration setting page on  the gateway or ZRC‐100 and input  parameter number “27” and  parameter value “000” to select the  dedicated AC code number “000”  for learning. 

Look up below mapping table (value 

0‐22) for learning, and decide the IR  setting you intent to learn next.  

For example “22°C, cool” which  matches value “5” (IR code to be  learnt will locate at “5” in ZW2‐IR).  

Set your original air conditioner  remote at “22°C, cool” and turn it  off. (Besides temperature and  mode, you may set other desired  settings, such as Fan, Swing etc.)   

Go to configuration setting page on  the gateway or ZRC‐100 and input  parameter number “25” and  parameter value “5” (in this case).  

Press the PROG button on the ZW2‐

IR.  (this step apply when using 

ZRC‐100 or other portable controller  for set up, if using gateway, user can  skip this step) 

Aim the original air conditioner  remote at ZW2‐IR  according to  below position within 1‐3 inches 

LED Indication Status  on ZW2‐IR  

• LED flashes once   when ZW2‐IR   receives the  configuration  setting 

‐ 

‐ 

• LED flashes once   when ZW2‐IR   receives the  configuration  setting 

• ZW2‐IR  is ready to  learn 

 

LED flashes twice if  learning is successful. 

LED flashes 6 times if  it’s failed.  

13

 

Press “power on” button on the  original air conditioner remote. 

 

If the learning is failed, repeat step 3  to step 5. 

To learn next IR code, repeat step 2  to step 5. 

 

 

 

 

 

 

 

 

 

 

 

 

 

L   When you encounter problem, check followings: 

− Make sure your original remote is switched to power off. 

− Press  the  key  on  original  remote  before  learning  mode  timeout. 

− Keep away from incandescent light and direct sunlight during  learning. 

− Make sure IR Transmitter of your original remote alight with  learning diode of ZW2‐IR,  you may also slight adjust closer or  further  away  the  distance  of  two  devices.  Some  of  remotes  the IR transmitter in hidden behind lens and may not installed  center of remote. 

− Make sure the power is good on both devices, especially the  original remote. Use fresh batteries. 

14

 

 

 

 

 

 

 

 

IR Learning Mapping Table (Parameter number 25) 

Parameter Value 

(Location) 

Thermostat command 

& IR setting 

0  OFF 

11 

12 

13 

14 

10 

15 

16 

17 

18 

19 

20 

21 

22 

ON (resume) 

19°C cool 

20°C cool 

21°C cool 

22°C cool 

23°C cool 

24°C cool 

25°C cool 

26°C cool 

27°C cool 

28°C cool 

19°C heat 

20°C heat 

21°C heat 

22°C heat 

23°C heat 

24°C heat 

25° C heat 

26°C heat 

27°C heat 

28°C heat 

Dry mode  

 

 

 

 

 

 

 

 

 

 

 

Default Cool

 

 

 

 

 

 

 

 

 

 

 

Default Heat

15

 

L Important Information 

After all learning completed, user can go back to the ZW2‐IR   control page on the gateway for normal operation. 

− On the gateway UI, user can only use the temperature range  from  the  mapping  table,  OFF,  ON(RESUME),  COOL,  HEAT, 

DRY, If user press the button of FAN, or other function on the  gateway UI which is not listed in above table, ZW2‐IR  will not  respond. 

− If user only learnt ON, OFF, or part of the settings according  to  the  above  table,  ZW2‐IR   will  send  the  learnt  data  to  the  air  conditioner  only.  For  example,  user  only  learnt  ON,  OFF, 

22°C  Cool,  24°C  Heat,  ZW2‐IR   will  not  send  IR  data  to  air  conditioner if user set 27°C Cool on the gateway.  

− ZW2‐IR   has  been  pre‐defined  default  cool  at  26°C,  default  heat  at  22°C,  when  user  press  Cool  on  gateway  without  setting temperature, ZW2‐IR  will send the learnt data of 26°C 

Cool  to  air  conditioner.    When  user  press  Heat  on  gateway  without  setting  temperature,  ZW2‐IR   will  send  the  learnt  data of 22°C Heat to air conditioner. 

− There  is  only  one  code  for  dry  mode,  user  can  set  it  at  any  preferred temperature.  

− User can still use gateway to set up scene and schedule with 

ZW2‐IR,  for example, to have AC turn on at 23°C every day at 

7pm, 25°C at 11pm. Just make sure the set code is learnt. 

 

 

 

Reset ZW2‐IR  to factory default 

 

Press and hold “PROG” button for 10seconds on ZW2‐IR.  The LED will  flash twice until reset process is completed.  

Note: This reset step will not affect the operation mode of ZW2‐IR,   user should refer to 

Listening Mode

 section if you want to change  the operation mode. 

L   Information 

− If  you  are  using  Gateway  or  other  Z‐wave  controllers  to  operate  ZW2‐IR,   Please  follow  the  instruction  from  the  gateway or other controller. 

− You can check either the specifications in the manual of your 

ZW2‐IR   or  also  check  online  at  www.wintop.com

full list of products that can be used with your ZW2‐IR.  

  for  a 

16

INSTALLATION 

MOUNTING THE ZW2‐IR  TO A WALL 

MOUNTING LOCATION PRECAUTIONS 

• Before mounting, check the material and structure of the  mounting location. If the location does not have the proper  material or structure, the ZW2‐IR  can fall and cause injuries. 

• Use commercial items that best match the wall structure and  material for the screws and other fixtures. 

• Do not mount near a kitchen counter, humidifier, or other  location in which it can be exposed to smoke or steam. Doing so  could cause a fire or electrical shock. 

• Do not mount in locations with high humidity or large amounts of  dust. Doing so could cause a fire or electrical shock. 

• Do not mount to locations subject to high temperatures, high  humidity, or exposure to water. Doing so could cause a fire or  electrical shock. 

• Do not mount to locations subject to large amounts of vibration,  large jolts, or large forces. These could cause an injury if the ZW2

IR  falls and breaks. 

 

MOUNTING PROCEDURE PRECAUTIONS 

• Do not modify parts or use the ZW2‐IR  in ways other than its  intended use. Doing so could cause the ZW2‐IR  to fall and result  in an injury. 

• Be sure to fully check that there are no electrical wires or pipes  inside the wall before mounting. 

• If any of the screws are loose, the ZW2‐IR  can fall and cause an  injury. Do not mount the ZW2‐IR  with the screws still loose. 

• Check that the two screws mounted to the wall are fully inserted  into the key holes of the ZW2‐IR.  Otherwise, the ZW2‐IR  can fall  and cause an injury. 

• Do not mount the ZW2‐IR  so that it sticks out from the wall edge. 

It could get hit by people’s bodies or objects and cause an injury. 

• Supplier will not be liable for any accidents or injuries that occur  due to improper mounting or handling. 

• When mounting, be careful not to get your fingers pinched or  injure your hands. 

 

 

MOUNTING PROCEDURE 

The ZW2‐IR  can be mounted to a wall or wooden racks using the two  key holes in the bottom case.  

 

Note 1: The reception sensitivity varies depending on the antenna direction.

17

Note 2: Before mounting to a wall, be sure to fully read the precautions.

 

 

1. Obtain two screws suitable for the wall strength and material. 

The screw size is shown in the figure below. 

 

 

2. The positional relationship between the ZW2‐IR  key holes and  the screw mounting positions are shown in the figure below. 

Note 1: When mounting the screws to the wall, leave a space between the wall and screw cap as shown in the figure.

 

 

 

 

3. Insert the ZW2‐IR  key holes onto the two screws mounted to  the wall, and then slide downward to secure in place. 

 

4. After securing the ZW2‐IR  to the wall, connect the USB Power  or batteries and IR emitter cable to the ZW2‐IR.  

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1: Check that the ZW2IR is firmly secured to the wall.

Note 2: Insert USB plug or batteries and IR emitter cable so that they are firmly connected to the ZW2IR.

5. When removing the ZW2‐IR  from the wall, lift up the ZW2‐IR,   then pull it towards you. 

 

 

6. Detach the main unit from the battery chassis by move toward  to top position. 

 

19

WIRELESS INFORMATION 

Wireless range: 

This device has an open‐air line‐of‐sight transmission distance of 100  feet which complies with the Z‐Wave standards. Performance can vary  depending on the amount of objects in between Z‐Wave devices such  as walls and furniture. Every Z‐Wave device set up in your network will  act as a signal repeater allowing devices to talk to each other and find  alternate routes in the case of a reception dead spot. 

Radio frequency limitations: 

1. Each wall or object (i.e.: refrigerator, bookshelf, large TV, etc) can  reduce the maximum range of 65 feet by up to 25 to 30%. 

2. Plasterboard and wooden walls block less of the radio signal then  concrete, brick or tile walls which will have more of an effect on  signal strength. 

3. Wall mounted Z‐Wave devices will also suffer a loss of range if  they are housed in metal junction boxes which could also reduce  the range by up to 25 to 30%. 

MAINTENANCE 

 

1 Do not expose your ZW2‐IR  to dust, strong sunlight, humidity,  high temperatures or mechanical shocks. 

2 Do not use old and new batteries together as old batteries tend to  leak. 

3 Do not use corrosive or abrasive cleansers on your ZW2‐IR.  

4 Keep the unit dust free by wiping it with a soft, dry cloth. 

 

 

5 Do not disassemble your ZW2‐IR,  it contains no user‐serviceable  parts. 

 

FREQUENTLY ASKED QUESTIONS 

Z‐Wave Frequently Asked Questions 

 

Q  Why won’t my ZW2‐IR  work with the Z‐Wave devices I  purchased from another country? 

A  Due to different countries regulations Z‐Wave products from  different regions are set to different frequencies. Before  purchasing new devices make sure you have checked that the  device is compatible in your region.  

 

Q  How do I know which product is compatible with my ZW2‐IR?  

A   ZW2‐IR  should work with any Z‐Wave controller or gateway that  has control capability for “Thermostat” devices. You can check  either the specifications in the manual of your ZW2‐IR  or also  check online at  www.wintop.com

 for a full list of products  that can be used with your ZW2‐IR.  All Z‐Wave products also  come with the Z‐Wave logo. 

20

 

 

Q  Can I use the USB port to configure ZW2‐IR?  

A    No, the mini USB port only provides an alternative option for user  to power the ZW2‐IR.  

 

Q  Do I need an electrician to install Z‐Wave products in my house? 

A  Installation can be simple. In some cases all you need to do is  mount the ZW2‐IR  to a wall or wooden racks. You also can place  the ZW2‐IR  on the desk and power it with dry cell batteries. 

Q  How to select my air‐conditioner IR code from ZW2‐IR?  

A  You should refer to the code list and look into the brand and try  the code no. sequentially until you find the right code. You can  record down your device code under the table for future  reference after setting up the ZW2‐IR  correctly. 

Q  ZW2‐IR  is working on top and 4‐directions IR output, but there 

is no response on the IR emitter socket, why?   

A  ZW2‐IR  supports two IR power levels for the external IR emitter  to avoid saturation of the IR receiver. You can set the IR output  power level by the Parameter Table value (normal or high power  mode) or adjust the position of your external IR emitter. 

 

Q  Can I use 2 or more ZW2‐IR  in my house? What is the max. units  if yes? 

A  Yes and it is very depend on the capability of gateway / controller. 

For example, gateway can supports up to 8, 16 or 32 ZW2‐IR  in a  network.  

 

Q  How to avoid the IR interference if I am using 2 identical air‐ conditioners in same location but want to control them  individually?  

A  User can disable the Surround IR Output function, connect the  external IR emitter and aim it at the specific AC unit. The  operating distance of external IR emitter is around 100cm (High  power mode) and 50cm (Low power mode) but it is also depends  on the sensitivity of the IR receiver. 

 

External IR emitter cable 

21

 

 

Q   Where can I keep up to date with the latest Z‐Wave products for  my house? 

A   You can keep up to date by visiting the  www.wintop.com

  website where we will have information and ideas for using Z‐

Wave technology. 

 

TECHNICAL SPECIFICATIONS 

Model no. 

RF frequency 

RF operating distance 

BW8377EU (ZW2‐IREU)  

BW8377AU (ZW2‐IRAU)  

BW8377US (ZW2‐IRUS)  

BW8377IN (ZW2‐IRIN)  

868.4MHz (EU) (ZW2‐IREU)  

921.4MHz (AU) (ZW2‐IRAU)  

908.4MHz (US) (ZW2‐IRUS)  

865.22MHz (IN) (ZW2‐IRIN)   up to 80ft outdoor line of sight, in unobstructed  environment 

IR operating distance  up to 25ft line of sight, in unobstructed environment

IR learning  

Temperature  

Powered by 

Dimension  

Weight  

Max.  23 commands 

Measurable range: 32 – 104 °F / 0 – 40 °C 

Operation: 0 ‐ 40°C 

Storage: ‐20 ‐ 60°C 

USB Power DC 5V 100mA or  

Dry battery AAA x 3pcs 

Dia.=70mm, T = 18mm (Main unit) 

Dia.=70mm, T = 15.5mm (Battery chassis) 

35g (Battery chassis excluded) 

60g (Battery chassis included) 

90g (Main + Battery chassis + AAA x3pcs) 

Z‐Wave device type 

Basic Device Class: BASIC_TYPE_ROUTING_SLAVE

 

Generic Device Class: GENERIC_TYPE_THERMOSTAT

 

Specific Device Class: SPECIFIC_TYPE_THERMOSTAT_GENERAL_V2

 

Z‐Wave Command Class  Version Controlled   Supported 

COMMAND_CLASS_THERMOSTAT_MODE   Version2  NO  YES 

COMMAND_CLASS_THERMOSTAT_SETPOINT  Version2  NO  YES 

COMMAND_CLASS_THERMOSTAT_FAN_MODE 

COMMAND_CLASS_BATTERY 

Version2  NO 

Version1  NO 

YES 

YES 

22

COMMAND_CLASS_CONFIGURATION 

COMMAND_CLASS_BASIC 

COMMAND_CLASS_VERSION 

COMMAND_CLASS_SENSOR_MULTILEVEL 

COMMAND_CLASS_SWITCH_ALL 

COMMAND_CLASS_MANUFACTURER_SPECIFIC 

Version1  NO 

Version1  NO 

Version1  NO 

Version1  NO 

Version1  NO 

Version1  NO 

Supported function in Thermostat Command Class 

Z‐Wave command class  Description 

Auto/Auto Low 

Thermostat Fan mode

Low 

Auto High 

High 

Auto Medium 

Medium 

Thermostat Set point

Thermostat Mode

Heating 

Cooling 

Furnace 

Dry Air 

Moist Air 

Auto changeover 

Energy Save heating 

Energy Save cooling 

Away heating 

Off 

Heat 

Cool 

Auto 

Auxiliary/Emergency Heat 

Resume 

Fan only 

Furnace 

Dry Air 

Moist Air 

23

NO 

YES 

YES 

NO 

YES 

NO 

YES 

YES 

YES 

YES 

NO 

YES 

NO 

NO 

NO 

YES 

YES 

NO 

YES 

Supported 

YES 

YES 

YES 

YES 

YES 

YES 

YES 

YES 

YES 

YES 

YES 

YES 

Auto Changeover 

Energy Save Heat 

Energy Save Cool 

AWAY 

ZW2‐IR  functions and Parameters summaries: 

FUNCTIONS

AIR

CONDITIONER

FUNCTION

Z-WAVE COMMAND CLASS

COMMAND_CLASS_THERMOSTAT

_MODE

POWER ON

YES 

NO 

NO 

NO 

Z-WAVE

COMMAND

THERMOSTAT_

MODE_SET

COMMAND

PARAMETER

MODE = 5

POWER

COMMAND_CLASS_THERMOSTAT

_MODE

THERMOSTAT_

MODE_SET

MODE = 0

POWER OFF

MODE

FAN SPEED

AUTO

COOL

FAN

HEAT

DRY

AUTO

Changeover

HEAT mode

Temperature

TEMPERATURE

SETTING

COOL mode

Temperature

DRY mode

Temperature

AUTO mode

Temperature

FAN AUTO

COMMAND_CLASS_THERMOSTAT

_MODE

COMMAND_CLASS_THERMOSTAT

_MODE

COMMAND_CLASS_THERMOSTAT

_MODE

COMMAND_CLASS_THERMOSTAT

_MODE

COMMAND_CLASS_THERMOSTAT

_MODE

COMMAND_CLASS_THERMOSTAT

_MODE

COMMAND_CLASS_THERMOSTAT

_SETPOINT

COMMAND_CLASS_THERMOSTAT

_FAN_MODE, v1

COMMAND_CLASS_THERMOSTAT

_FAN_MODE, v2

THERMOSTAT_

MODE_SET

THERMOSTAT_

MODE_SET

THERMOSTAT_

MODE_SET

THERMOSTAT_

MODE_SET

THERMOSTAT_

MODE_SET

THERMOSTAT_

MODE_SET

MODE = 3

MODE = 2

MODE = 6

MODE = 1

MODE = 8

THERMOSTAT_

SETPOINT_SET

MODE = 10

SETPOINT TYPE =

1,

TEMPERATURE

VALUE

SETPOINT TYPE =

2,

TEMPERATURE

VALUE

SETPOINT TYPE =

8,

TEMPERATURE

VALUE

SETPOINT TYPE =

10,

TEMPERATURE

VALUE

THERMOSTAT_

FAN_MODE_SE

T

THERMOSTAT_

FAN_MODE_SE

T

FAN MODE = 0

FAN MODE = 0, 2, or

4

24

FAN LOW (1/3)

COMMAND_CLASS_THERMOSTAT

_FAN_MODE, v1

COMMAND_CLASS_THERMOSTAT

_FAN_MODE, v2

THERMOSTAT_

FAN_MODE_SE

T

THERMOSTAT_

FAN_MODE_SE

T

FAN MODE = 1

FAN MODE = 1

SWING

IR CODE SETUP

IR

TRANSMISSION

POWER LEVEL

FAN MID (2/3)

FAN HIGH (3/3)

SWING ON/

SWING AUTO

SWING OFF

NORMAL

POWER LEVEL

HIGH POWER

LEVEL

FRONT IR

TRANSMISSION

CONTROL

DISABLE

ENABLE

COMMAND_CLASS_THERMOSTAT

_FAN_MODE, v2

COMMAND_CLASS_THERMOSTAT

_FAN_MODE, v1

COMMAND_CLASS_THERMOSTAT

_FAN_MODE, v2

COMMAND_CLASS_CONFIGURATI

ON

COMMAND_CLASS_CONFIGURATI

ON

COMMAND_CLASS_CONFIGURATI

ON

COMMAND_CLASS_CONFIGURATI

ON

COMMAND_CLASS_CONFIGURATI

ON

COMMAND_CLASS_CONFIGURATI

ON

COMMAND_CLASS_CONFIGURATI

ON

25

THERMOSTAT_

FAN_MODE_SE

T

THERMOSTAT_

FAN_MODE_SE

T

THERMOSTAT_

FAN_MODE_SE

T

FAN MODE = 5

FAN MODE = 3

FAN MODE = 3

CONFIGURATIO

N_SET

PARAMETER NO. =

33

SIZE = 1

CONFIGURATIO

N_SET

VALUE = 1

PARAMETER NO. =

33

SIZE = 1,

CONFIGURATIO

N_SET

VALUE = 0

PARAMETER NO. =

27

SIZE = 2,

CONFIGURATIO

N_SET

VALUE = (CODE#)

PARAMETER NO. =

28

SIZE = 1,

CONFIGURATIO

N_SET

VALUE = 0

PARAMETER NO. =

28

SIZE = 1,

CONFIGURATIO

N_SET

VALUE = 0xFF

PARAMETER NO. =

32

SIZE = 1,

CONFIGURATIO

N_SET

VALUE = 0

PARAMETER NO. =

32

BATTERY

LEVEL

VERSION

MANUF'ER

SPECIFIC

TEMPERATURE

SENSOR

COMMAND_CLASS_MANUFACTUR

ER_SPECIFIC

COMMAND_CLASS_SENSOR_MUL

TILEVEL

MANUFACTURE

R_SPECIFIC_GE

T

SENSOR_MULTI

LEVEL_GET

SIZE = 1,

VALUE = 0xFF

26

 

CHECKING ACCESSORIES 

After opening the cover of the packing box, check that the following  accessories are included.  

• ZW2IR  (Z‐Wave‐to‐AC IR Extender) 

• Screws (bottom cover) x 2pcs 

• ZW2‐IR  User Manual (download from our website) 

• AC Code List (download from our website) 

 

FCC NOTICE 

This device complies with Part 15 of the FCC rules. Operation is  subject to the following two conditions:  

(1) this device may not cause harmful interference, and  

(2) this device must accept any interference received, including  interference that may cause undesired operation. 

WARNINGS 

Changes or modifications not expressly approved by the party  responsible for compliance could void the user's authority to operate  the equipment. 

‐ RISK OF FIRE 

‐ RISK OF ELECTRICAL SHOCK 

‐ RISK OF BURNS 

‐ The socket‐outlet shall be installed near the equipment and  shall be easily accessible. 

‐ Use only power supplies listed in the user instructions. 

 

Do not dispose of electrical appliances as unsorted municipal waste,  use separate collection facilities. Contact your local government for 

  information regarding the collection systems available. 

CAUTION 

 

 

 

 

 

 

 

 

‐   RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT 

TYPE. 

‐   DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS. 