Z-Wave ZRC-100 Specifications
Add to my manuals27 Pages
Z-Wave ZRC-100 is a wireless remote control that gives you the ability to control various Z-Wave devices in your smart home system such as lights, switches, thermostats, door locks, and more. With its 4 customizable buttons, you can easily program them to activate scenes, toggle devices on/off, or adjust brightness levels, providing quick and easy access to your most frequently used smart home functions. It also features a compact and sleek design that blends seamlessly into any décor, making it a convenient and stylish addition to your smart home setup.
advertisement
ZW2IR installation
ZW2IR
(Z-Wave-to-AC IR Extender)
Firmware Version: V06
1
Table of Contents
Introduction .................................................... 3
Controller and Gateway Requirements ............ 4
Built-in IR code library .................................... 4
Glossary .......................................................... 5
ZW2IR Oper ations ........................................ 6
Product Overview ............................................. 7
Z-Wave Remote Control ................................... 8
ZW2IR Inform ation ....................................... 9
Listening Mode Change .................................... 11
IR Code Selection ............................................ 11
IR Code Learning ............................................ 13
Reset ZW2IR to fa ctory default........................ 16
INSTALLATION ................................................ 17
MOUNTING THE ZW2 IR TO A WALL.................. 17
WIRELESS INFORMATION ............................... 20
MAINTENANCE................................................. 20
FREQUENTLY ASKED QUESTIONS .................... 20
Z-Wave Frequently Asked Questions ................... 20
TECHNICAL SPECIFICATIONS.......................... 22
CHECKING ACCESSORIES ................................ 27
FCC NOTICE .................................................... 27
WARNINGS...................................................... 27
CAUTION ........................................................ 27
2
Introduction
Z-Extender
TM
ZW2IR
(Z-Wave-to-AC IR Extender)
Operating Instructions
The ZW2 IR is a Z‐Wave to IR extender for air‐conditioner (AC),
(Figure 1), it works with any Z‐Wave compliant gateway or controller by translating Z‐Wave Thermostat Commands to AC IR control code.
User can select the IR code from the built‐in code library of ‐ IR, or use learning function, by using Z‐Wave Configuration Commands
according to the parameter table. ‐ IR is also with built‐in temperature sensor which allows gateway or controller to get the current room temperature.
Figure 1 ZW2IR
‐ IR can be configured as either “Frequently Listening Routing
Slaves” (FLiRS) or “Always Listening” node after exclusion process
(before inclusion process).
FLiRS node type is for battery operated applications and it will enter sleep mode frequently in order to conserve battery consumption that can provide the flexibility if there is out of 5Vdc power source. Also,
user can place the unit in anywhere at home.
Always Listening node type is for the needs of fast response application. It works with 5Vdc power source. Always Listening node can act as a repeater, which will re‐transmit the RF signal to ensure that the signal is received by its intended destination by routing the
signal around obstacle and radio dead spots.
‐ IR supports Network Wide Inclusion (NWI) and Explore Frames.
It also supports Z‐Wave networks with multiple gateways and controllers. Like every Z‐Wave accessory, user will need to include the
3
‐ IR into their Z‐Wave network using the primary controller. Then, the user can use either the primary controller or secondary controller to configure and setup the ‐ IR using Z‐Wave’s configuration command class. Once the configuration and setup is complete, the
controller can use Z‐Wave “Thermostat commands class” to control their IR‐controlled air‐conditioner through the ‐ IR.
Controller and Gateway Requirements
The ‐ IR can work with any Z‐Wave compliant controller or gateway supporting the following Z‐Wave commands.
- Configuration Command Class
- Multilevel Sensor Command Class
- Thermostat Command Class
Thermostat Mode Command Class
Thermostat Fan Mode Command Class
Thermostat Set‐point Command Class
Built‐in IR code library
The Built‐in IR code library supports most of the popular air
conditioner brands in the market. Z‐Wave gateway and controller does not need to have any IR control code knowledge. User can use Z‐
Wave controller or gateway to select the IR code according to the ZW2
IR code list separately provided through Z‐Wave configuration command.
4
Glossary
Device or
Node
Inclusion
Exclusion
Remove
Z‐Wave
Network
Primary
Controller
Secondary
Controller
Inclusion
Controller
Devices and nodes are all terms to describe an individual Z‐Wave device. These are all interchangeable when setting up your Z‐Wave network.
Add a Z‐Wave device to the network.
Delete a Z‐Wave device from the network.
To take a device out of a group, scene or association group while that device still exists in the same Z‐Wave network.
A collection of Z‐Wave devices is controlled by primary and secondary controllers operating on the same system. A Z‐Wave network has its own unique ID code so that controllers not in the network cannot control the system.
The first controller is used to set up your devices and network. Only the Primary
Controller can be used to include or delete devices from a network. It is recommended that you mark the primary controller for each network for ease in modifying your network.
A controller containing network information about other devices within the network and is used for controlling devices. Secondary controller is created from the Primary
Controller and cannot include or delete devices to the network.
A controller containing network information about other devices within the network and is used for controlling devices. Inclusion controller is created from the Primary
Controller in a SIS enabled Z‐Wave network.
Inclusion Controllers have the ability to add and remove devices from the network.
5
ZW2‐IR Operations
Before using the ZW2‐IR, please read the [INSTALLATION] if you need to mount the ZW2‐IR to a wall. Power up the ZW2‐IR by the USB
Power 5Vdc or Dry battery AAA x 3pcs.
• Plug‐in 5Vdc power into the USB socket if operated at Always
Listening mode. Or
• Install 3xAAA batteries if operated at FLiRS mode.
• Please refer to the section of [MOUNTING PROCEDURE].
• Remove the battery cover on the back of your ZW2‐IR battery chassis.
• Mount the battery cover into the main unit with 2 screws.
• Check the polarity of the batteries and the "+/‐" marks inside the
battery compartment.
• Insert the batteries.
• Push the battery cover and main unit back in place.
L CAUTION (battery and power adaptor safety)
− Use new batteries of the recommended type and size only.
− Never mix used and new batteries together.
− To avoid chemical leaks, remove batteries from the ZW2‐IR if you do not intend to use the remote for an extended period of time.
− Dispose of used batteries properly; do not burn or bury them.
(Please carefully read through the following then store the manual for
future reference.)
6
Product Overview
“PROG” Button,
Learning and LED
Indication
Temperature sensor
External
IR Port top and 4-directions
USB Power
Surround IR Output for
5V DC
Figure 2 PROG Key and IR Port of ZXT-120
7
Battery chassis
Z‐Wave Remote Control
1) Select your operation mode; please refer to “Listening Mode” section.
2) Include or Exclude the unit from the existing Z‐Wave home control network with your primary controller.
‐ Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.
‐
‐
When prompted by your primary controller, click once on the PROG button.
The primary controller should indicate that the action was successful. If the controller indicates the action was unsuccessful, please repeat the procedure.
3) User can use either primary controller or secondary controller
(should support configuration command class) to setup the ZW2‐
IR AC code by the parameter 27 (IR code number for built‐in code library), please refer to code list for the parameter value then setup your AC control code.
4) Once the configuration and setup were completed, the controller can use Z‐Wave “Thermostat commands class” to control their IR‐controlled air‐conditioner with the ZW2‐IR.
5) You can record down your device code under the below table for future reference after setting up the ZW2‐IR correctly.
AC device programmed to your ZW2‐IR
Code no.:
8
ZW2
How to get the NIF “Node Information Frame” on ZW2‐IR (Inclusion)
Step Setup Key
Press the PROG button on the
ZW2‐IR
LED Indication Status on ZW2‐IR
• LED flashes once then stay off
1
(ZW2‐IR will report the supported command class)
Parameter No. and Parameter Value of configuration command
Parameter
Number
25
(0x19)
26
(0x1A)
Definitions
Indicate a location for IR code learning and start learning
Learning status register
Note:
The status value 0x01 and
0x04 will be reset to 0 when the ZXT‐120 receive a get command to this parameter
Parameter Value
0‐22
(0x00 – 0x16)
0x00: Idle ‐ this IR channel is idle
(default)
0x01: OK ‐ the latest learning process successful and
completed
0x02: Learning ‐ the
ZXT‐120 is busy processing previous learning request
0x04: Failed ‐ the latest learning request failed
27
(0x1B)
IR code number for built‐in code library
Refer “Code list” for details
28
(0x1C)
32
(0x20)
External IR Emitter power level
Surround IR control
- to avoid the IR interference by disabling the surrounding IR emitter if 2
0x00: normal power mode
0xFF: high power mode (default)
0x00: disable
Surround IR Emitters
0xFF: enable
Surround IR Emitters
9
33
(0x21)
35
(0x23) air‐conditioners in a room are used
- extend the battery life by disabling the Surround IR
Emitters
(default)
AC function “SWING” control 0x00: SWING OFF
0x01: SWING AUTO
Learn location status
(Default)
Bit mask = 1, learn location has learn data. Otherwise, Bit mask = 0
See figure “Learn
location” as below
Parameter Table
7
1
6
0
5
0
4
0
3 2 1 0
0 0 1 0 Bit Mask Byte 1
Location 0‐7
7
0
6
0
5
0
4
1
3 2 1 0
0 0 0 1
Bit Mask Byte 2
Location 8‐15
7
0
6
0
5
0
4
0
3 2 1 0
0 0 0 1
Bit Mask Byte 3
Location 16‐23
7 6 5 4 3 2 1 0
0 0 0 0 0 0 0 0
Bit Mask Byte 4
[Reseved]
Figure: Learn location
On the above example, location 1, 7, 8, 12, 16 has learned data.
L Mapping Information
− BASIC Set Value 0x00 will map to Thermostat mode Off 0x00.
− BASIC set Value 0xFF will map to Thermostat mode Resume 0x05.
10
Listening Mode Change (default mode is FLiRS)
ZW2‐IR can be configured as either “Frequently Listening Routing
Slaves” (FLiRS) or “Always Listening” node after exclusion process.
FLiRS node type is targeted for battery operated applications and it will enter sleep mode frequently in order to conserve battery consumption.
Always Listening node type is targeted for the needs of required a fast response application.
Important:
It is not allowed to changing ZW2‐IR operation mode without exclusion process (do not change ZW2‐IR operation mode while ZXT‐
120 is included in a network).
How to switch ZW2‐IR listening mode from “Always Listening" to
“FLiRS" (or vice verse)
Step
1
Setup Key
Press and hold the PROG button on the ZW2‐IR for around 4 seconds
LED Indication Status on ZW2‐IR
• LED stay off
• LED flashes twice then stay off
Release the button and then press the PROG button 3 times within 3 seconds
2
(ZW2‐IR set in FLiRS mode)
OR
• LED flashes four times then stay off
(ZW2‐IR set in
Always Listening mode)
IR Code Selection
ZW2‐IR is with built‐in IR AC code library, user may select the IR code
using Configuration Command Class.
Step Setup Key
LED Indication Status on ZW2‐IR
11
1
2
3
4
After included ZW2‐IR to Z‐Wave controller or Gateway, go to device setup for configuration on gateway or controller.
Input parameter number “27” and parameter value (please look up the code list of ZW2IR according to your AC brand). Then complete the configuration process.
Press the PROG button on the ZW2‐
IR. (this step apply when using
ZRC‐100 or other portable controller for set up, if using gateway, user can skip this step)
Go back to the control page of ZW2‐
IR on the gateway and try the function such as (cool, temperature set).
If the air conditioner does not respond to the command you set on
Gateway (Cool, Heat, Auto,
Temperature set etc.), repeat step 2 and 3 to select the next code on code list.
‐
‐
• LED flashes once when ZW2‐IR receives the configuration setting
• LED flashes once every time it receives a command from gateway
L Important Information
− Different brand or model of air conditioner has different function. For example, some air conditioner only support temperature set from 18 o
C‐30 o
C, if user set 17
o
C on gateway,
ZW2‐IR will not respond.
− There are more than 1 code for each brand, some does not support heat, if user selected a code that does not support heat but the original air conditioner supports heat function, please continue to try next code until the correct one is selected.
− If none of the code works on the target air conditioner, or the air conditioner brand is not shown on the code list, please select code “000” for IR code learning (refer to instruction of
IR Code Learning)
12
IR Code Learning
In case none of the code on the code list works for the targeted air conditioner, user can use IR code learning function using configuration according to below steps:
Step
1
2
3
4
5
Setup Key
Go to configuration setting page on the gateway or ZRC‐100 and input parameter number “27” and parameter value “000” to select the dedicated AC code number “000” for learning.
Look up below mapping table (value
0‐22) for learning, and decide the IR setting you intent to learn next.
For example “22°C, cool” which matches value “5” (IR code to be learnt will locate at “5” in ZW2‐IR).
Set your original air conditioner remote at “22°C, cool” and turn it off. (Besides temperature and mode, you may set other desired settings, such as Fan, Swing etc.)
Go to configuration setting page on the gateway or ZRC‐100 and input parameter number “25” and parameter value “5” (in this case).
Press the PROG button on the ZW2‐
IR. (this step apply when using
ZRC‐100 or other portable controller for set up, if using gateway, user can skip this step)
Aim the original air conditioner remote at ZW2‐IR according to below position within 1‐3 inches
LED Indication Status on ZW2‐IR
• LED flashes once when ZW2‐IR receives the configuration setting
‐
‐
• LED flashes once when ZW2‐IR receives the configuration setting
• ZW2‐IR is ready to learn
LED flashes twice if learning is successful.
LED flashes 6 times if it’s failed.
13
Press “power on” button on the original air conditioner remote.
If the learning is failed, repeat step 3 to step 5.
To learn next IR code, repeat step 2 to step 5.
L When you encounter problem, check followings:
− Make sure your original remote is switched to power off.
− Press the key on original remote before learning mode timeout.
− Keep away from incandescent light and direct sunlight during learning.
− Make sure IR Transmitter of your original remote alight with learning diode of ZW2‐IR, you may also slight adjust closer or further away the distance of two devices. Some of remotes the IR transmitter in hidden behind lens and may not installed center of remote.
− Make sure the power is good on both devices, especially the original remote. Use fresh batteries.
14
IR Learning Mapping Table (Parameter number 25)
Parameter Value
(Location)
Thermostat command
& IR setting
0 OFF
11
12
13
14
8
9
10
3
4
5
1
2
6
7
15
16
17
18
19
20
21
22
ON (resume)
19°C cool
20°C cool
21°C cool
22°C cool
23°C cool
24°C cool
25°C cool
26°C cool
27°C cool
28°C cool
19°C heat
20°C heat
21°C heat
22°C heat
23°C heat
24°C heat
25° C heat
26°C heat
27°C heat
28°C heat
Dry mode
Default Cool
Default Heat
15
L Important Information
After all learning completed, user can go back to the ZW2‐IR control page on the gateway for normal operation.
− On the gateway UI, user can only use the temperature range from the mapping table, OFF, ON(RESUME), COOL, HEAT,
DRY, If user press the button of FAN, or other function on the gateway UI which is not listed in above table, ZW2‐IR will not respond.
− If user only learnt ON, OFF, or part of the settings according to the above table, ZW2‐IR will send the learnt data to the air conditioner only. For example, user only learnt ON, OFF,
22°C Cool, 24°C Heat, ZW2‐IR will not send IR data to air conditioner if user set 27°C Cool on the gateway.
− ZW2‐IR has been pre‐defined default cool at 26°C, default heat at 22°C, when user press Cool on gateway without setting temperature, ZW2‐IR will send the learnt data of 26°C
Cool to air conditioner. When user press Heat on gateway without setting temperature, ZW2‐IR will send the learnt data of 22°C Heat to air conditioner.
− There is only one code for dry mode, user can set it at any preferred temperature.
− User can still use gateway to set up scene and schedule with
ZW2‐IR, for example, to have AC turn on at 23°C every day at
7pm, 25°C at 11pm. Just make sure the set code is learnt.
Reset ZW2‐IR to factory default
Press and hold “PROG” button for 10seconds on ZW2‐IR. The LED will flash twice until reset process is completed.
Note: This reset step will not affect the operation mode of ZW2‐IR, user should refer to
“
Listening Mode
"
section if you want to change the operation mode.
L Information
− If you are using Gateway or other Z‐wave controllers to operate ZW2‐IR, Please follow the instruction from the gateway or other controller.
− You can check either the specifications in the manual of your
ZW2‐IR or also check online at www.wintop.com
full list of products that can be used with your ZW2‐IR.
for a
16
INSTALLATION
MOUNTING THE ZW2‐IR TO A WALL
MOUNTING LOCATION PRECAUTIONS
• Before mounting, check the material and structure of the mounting location. If the location does not have the proper material or structure, the ZW2‐IR can fall and cause injuries.
• Use commercial items that best match the wall structure and material for the screws and other fixtures.
• Do not mount near a kitchen counter, humidifier, or other location in which it can be exposed to smoke or steam. Doing so could cause a fire or electrical shock.
• Do not mount in locations with high humidity or large amounts of dust. Doing so could cause a fire or electrical shock.
• Do not mount to locations subject to high temperatures, high humidity, or exposure to water. Doing so could cause a fire or electrical shock.
• Do not mount to locations subject to large amounts of vibration, large jolts, or large forces. These could cause an injury if the ZW2
IR falls and breaks.
MOUNTING PROCEDURE PRECAUTIONS
• Do not modify parts or use the ZW2‐IR in ways other than its intended use. Doing so could cause the ZW2‐IR to fall and result in an injury.
• Be sure to fully check that there are no electrical wires or pipes inside the wall before mounting.
• If any of the screws are loose, the ZW2‐IR can fall and cause an injury. Do not mount the ZW2‐IR with the screws still loose.
• Check that the two screws mounted to the wall are fully inserted into the key holes of the ZW2‐IR. Otherwise, the ZW2‐IR can fall and cause an injury.
• Do not mount the ZW2‐IR so that it sticks out from the wall edge.
It could get hit by people’s bodies or objects and cause an injury.
• Supplier will not be liable for any accidents or injuries that occur due to improper mounting or handling.
• When mounting, be careful not to get your fingers pinched or injure your hands.
MOUNTING PROCEDURE
The ZW2‐IR can be mounted to a wall or wooden racks using the two key holes in the bottom case.
Note 1: The reception sensitivity varies depending on the antenna direction.
17
Note 2: Before mounting to a wall, be sure to fully read the precautions.
1. Obtain two screws suitable for the wall strength and material.
The screw size is shown in the figure below.
2. The positional relationship between the ZW2‐IR key holes and the screw mounting positions are shown in the figure below.
Note 1: When mounting the screws to the wall, leave a space between the wall and screw cap as shown in the figure.
3. Insert the ZW2‐IR key holes onto the two screws mounted to the wall, and then slide downward to secure in place.
4. After securing the ZW2‐IR to the wall, connect the USB Power or batteries and IR emitter cable to the ZW2‐IR.
18
Note 1: Check that the ZW2IR is firmly secured to the wall.
Note 2: Insert USB plug or batteries and IR emitter cable so that they are firmly connected to the ZW2IR.
5. When removing the ZW2‐IR from the wall, lift up the ZW2‐IR, then pull it towards you.
6. Detach the main unit from the battery chassis by move toward to top position.
19
WIRELESS INFORMATION
Wireless range:
This device has an open‐air line‐of‐sight transmission distance of 100 feet which complies with the Z‐Wave standards. Performance can vary depending on the amount of objects in between Z‐Wave devices such as walls and furniture. Every Z‐Wave device set up in your network will act as a signal repeater allowing devices to talk to each other and find alternate routes in the case of a reception dead spot.
Radio frequency limitations:
1. Each wall or object (i.e.: refrigerator, bookshelf, large TV, etc) can reduce the maximum range of 65 feet by up to 25 to 30%.
2. Plasterboard and wooden walls block less of the radio signal then concrete, brick or tile walls which will have more of an effect on signal strength.
3. Wall mounted Z‐Wave devices will also suffer a loss of range if they are housed in metal junction boxes which could also reduce the range by up to 25 to 30%.
MAINTENANCE
1 Do not expose your ZW2‐IR to dust, strong sunlight, humidity, high temperatures or mechanical shocks.
2 Do not use old and new batteries together as old batteries tend to leak.
3 Do not use corrosive or abrasive cleansers on your ZW2‐IR.
4 Keep the unit dust free by wiping it with a soft, dry cloth.
5 Do not disassemble your ZW2‐IR, it contains no user‐serviceable parts.
FREQUENTLY ASKED QUESTIONS
Z‐Wave Frequently Asked Questions
Q Why won’t my ZW2‐IR work with the Z‐Wave devices I purchased from another country?
A Due to different countries regulations Z‐Wave products from different regions are set to different frequencies. Before purchasing new devices make sure you have checked that the device is compatible in your region.
Q How do I know which product is compatible with my ZW2‐IR?
A ZW2‐IR should work with any Z‐Wave controller or gateway that has control capability for “Thermostat” devices. You can check either the specifications in the manual of your ZW2‐IR or also check online at www.wintop.com
for a full list of products that can be used with your ZW2‐IR. All Z‐Wave products also come with the Z‐Wave logo.
20
Q Can I use the USB port to configure ZW2‐IR?
A No, the mini USB port only provides an alternative option for user to power the ZW2‐IR.
Q Do I need an electrician to install Z‐Wave products in my house?
A Installation can be simple. In some cases all you need to do is mount the ZW2‐IR to a wall or wooden racks. You also can place the ZW2‐IR on the desk and power it with dry cell batteries.
Q How to select my air‐conditioner IR code from ZW2‐IR?
A You should refer to the code list and look into the brand and try the code no. sequentially until you find the right code. You can record down your device code under the table for future reference after setting up the ZW2‐IR correctly.
Q ZW2‐IR is working on top and 4‐directions IR output, but there
is no response on the IR emitter socket, why?
A ZW2‐IR supports two IR power levels for the external IR emitter to avoid saturation of the IR receiver. You can set the IR output power level by the Parameter Table value (normal or high power mode) or adjust the position of your external IR emitter.
Q Can I use 2 or more ZW2‐IR in my house? What is the max. units if yes?
A Yes and it is very depend on the capability of gateway / controller.
For example, gateway can supports up to 8, 16 or 32 ZW2‐IR in a network.
Q How to avoid the IR interference if I am using 2 identical air‐ conditioners in same location but want to control them individually?
A User can disable the Surround IR Output function, connect the external IR emitter and aim it at the specific AC unit. The operating distance of external IR emitter is around 100cm (High power mode) and 50cm (Low power mode) but it is also depends on the sensitivity of the IR receiver.
External IR emitter cable
21
Q Where can I keep up to date with the latest Z‐Wave products for my house?
A You can keep up to date by visiting the www.wintop.com
website where we will have information and ideas for using Z‐
Wave technology.
TECHNICAL SPECIFICATIONS
Model no.
RF frequency
RF operating distance
BW8377EU (ZW2‐IREU)
BW8377AU (ZW2‐IRAU)
BW8377US (ZW2‐IRUS)
BW8377IN (ZW2‐IRIN)
868.4MHz (EU) (ZW2‐IREU)
921.4MHz (AU) (ZW2‐IRAU)
908.4MHz (US) (ZW2‐IRUS)
865.22MHz (IN) (ZW2‐IRIN) up to 80ft outdoor line of sight, in unobstructed environment
IR operating distance up to 25ft line of sight, in unobstructed environment
IR learning
Temperature
Powered by
Dimension
Weight
Max. 23 commands
Measurable range: 32 – 104 °F / 0 – 40 °C
Operation: 0 ‐ 40°C
Storage: ‐20 ‐ 60°C
USB Power DC 5V 100mA or
Dry battery AAA x 3pcs
Dia.=70mm, T = 18mm (Main unit)
Dia.=70mm, T = 15.5mm (Battery chassis)
35g (Battery chassis excluded)
60g (Battery chassis included)
90g (Main + Battery chassis + AAA x3pcs)
Z‐Wave device type
Basic Device Class: BASIC_TYPE_ROUTING_SLAVE
Generic Device Class: GENERIC_TYPE_THERMOSTAT
Specific Device Class: SPECIFIC_TYPE_THERMOSTAT_GENERAL_V2
Z‐Wave Command Class Version Controlled Supported
COMMAND_CLASS_THERMOSTAT_MODE Version2 NO YES
COMMAND_CLASS_THERMOSTAT_SETPOINT Version2 NO YES
COMMAND_CLASS_THERMOSTAT_FAN_MODE
COMMAND_CLASS_BATTERY
Version2 NO
Version1 NO
YES
YES
22
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_BASIC
COMMAND_CLASS_VERSION
COMMAND_CLASS_SENSOR_MULTILEVEL
COMMAND_CLASS_SWITCH_ALL
COMMAND_CLASS_MANUFACTURER_SPECIFIC
Version1 NO
Version1 NO
Version1 NO
Version1 NO
Version1 NO
Version1 NO
Supported function in Thermostat Command Class
Z‐Wave command class Description
Auto/Auto Low
Thermostat Fan mode
Low
Auto High
High
Auto Medium
Medium
Thermostat Set point
Thermostat Mode
Heating
Cooling
Furnace
Dry Air
Moist Air
Auto changeover
Energy Save heating
Energy Save cooling
Away heating
Off
Heat
Cool
Auto
Auxiliary/Emergency Heat
Resume
Fan only
Furnace
Dry Air
Moist Air
23
NO
YES
YES
NO
YES
NO
YES
YES
YES
YES
NO
YES
NO
NO
NO
YES
YES
NO
YES
Supported
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
Auto Changeover
Energy Save Heat
Energy Save Cool
AWAY
ZW2‐IR functions and Parameters summaries:
FUNCTIONS
AIR
CONDITIONER
FUNCTION
Z-WAVE COMMAND CLASS
COMMAND_CLASS_THERMOSTAT
_MODE
POWER ON
YES
NO
NO
NO
Z-WAVE
COMMAND
THERMOSTAT_
MODE_SET
COMMAND
PARAMETER
MODE = 5
POWER
COMMAND_CLASS_THERMOSTAT
_MODE
THERMOSTAT_
MODE_SET
MODE = 0
POWER OFF
MODE
FAN SPEED
AUTO
COOL
FAN
HEAT
DRY
AUTO
Changeover
HEAT mode
Temperature
TEMPERATURE
SETTING
COOL mode
Temperature
DRY mode
Temperature
AUTO mode
Temperature
FAN AUTO
COMMAND_CLASS_THERMOSTAT
_MODE
COMMAND_CLASS_THERMOSTAT
_MODE
COMMAND_CLASS_THERMOSTAT
_MODE
COMMAND_CLASS_THERMOSTAT
_MODE
COMMAND_CLASS_THERMOSTAT
_MODE
COMMAND_CLASS_THERMOSTAT
_MODE
COMMAND_CLASS_THERMOSTAT
_SETPOINT
COMMAND_CLASS_THERMOSTAT
_FAN_MODE, v1
COMMAND_CLASS_THERMOSTAT
_FAN_MODE, v2
THERMOSTAT_
MODE_SET
THERMOSTAT_
MODE_SET
THERMOSTAT_
MODE_SET
THERMOSTAT_
MODE_SET
THERMOSTAT_
MODE_SET
THERMOSTAT_
MODE_SET
MODE = 3
MODE = 2
MODE = 6
MODE = 1
MODE = 8
THERMOSTAT_
SETPOINT_SET
MODE = 10
SETPOINT TYPE =
1,
TEMPERATURE
VALUE
SETPOINT TYPE =
2,
TEMPERATURE
VALUE
SETPOINT TYPE =
8,
TEMPERATURE
VALUE
SETPOINT TYPE =
10,
TEMPERATURE
VALUE
THERMOSTAT_
FAN_MODE_SE
T
THERMOSTAT_
FAN_MODE_SE
T
FAN MODE = 0
FAN MODE = 0, 2, or
4
24
FAN LOW (1/3)
COMMAND_CLASS_THERMOSTAT
_FAN_MODE, v1
COMMAND_CLASS_THERMOSTAT
_FAN_MODE, v2
THERMOSTAT_
FAN_MODE_SE
T
THERMOSTAT_
FAN_MODE_SE
T
FAN MODE = 1
FAN MODE = 1
SWING
IR CODE SETUP
IR
TRANSMISSION
POWER LEVEL
FAN MID (2/3)
FAN HIGH (3/3)
SWING ON/
SWING AUTO
SWING OFF
NORMAL
POWER LEVEL
HIGH POWER
LEVEL
FRONT IR
TRANSMISSION
CONTROL
DISABLE
ENABLE
COMMAND_CLASS_THERMOSTAT
_FAN_MODE, v2
COMMAND_CLASS_THERMOSTAT
_FAN_MODE, v1
COMMAND_CLASS_THERMOSTAT
_FAN_MODE, v2
COMMAND_CLASS_CONFIGURATI
ON
COMMAND_CLASS_CONFIGURATI
ON
COMMAND_CLASS_CONFIGURATI
ON
COMMAND_CLASS_CONFIGURATI
ON
COMMAND_CLASS_CONFIGURATI
ON
COMMAND_CLASS_CONFIGURATI
ON
COMMAND_CLASS_CONFIGURATI
ON
25
THERMOSTAT_
FAN_MODE_SE
T
THERMOSTAT_
FAN_MODE_SE
T
THERMOSTAT_
FAN_MODE_SE
T
FAN MODE = 5
FAN MODE = 3
FAN MODE = 3
CONFIGURATIO
N_SET
PARAMETER NO. =
33
SIZE = 1
CONFIGURATIO
N_SET
VALUE = 1
PARAMETER NO. =
33
SIZE = 1,
CONFIGURATIO
N_SET
VALUE = 0
PARAMETER NO. =
27
SIZE = 2,
CONFIGURATIO
N_SET
VALUE = (CODE#)
PARAMETER NO. =
28
SIZE = 1,
CONFIGURATIO
N_SET
VALUE = 0
PARAMETER NO. =
28
SIZE = 1,
CONFIGURATIO
N_SET
VALUE = 0xFF
PARAMETER NO. =
32
SIZE = 1,
CONFIGURATIO
N_SET
VALUE = 0
PARAMETER NO. =
32
BATTERY
LEVEL
VERSION
MANUF'ER
SPECIFIC
TEMPERATURE
SENSOR
COMMAND_CLASS_MANUFACTUR
ER_SPECIFIC
COMMAND_CLASS_SENSOR_MUL
TILEVEL
MANUFACTURE
R_SPECIFIC_GE
T
SENSOR_MULTI
LEVEL_GET
SIZE = 1,
VALUE = 0xFF
26
CHECKING ACCESSORIES
After opening the cover of the packing box, check that the following accessories are included.
• ZW2IR (Z‐Wave‐to‐AC IR Extender)
• Screws (bottom cover) x 2pcs
• ZW2‐IR User Manual (download from our website)
• AC Code List (download from our website)
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
WARNINGS
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
‐ RISK OF FIRE
‐ RISK OF ELECTRICAL SHOCK
‐ RISK OF BURNS
‐ The socket‐outlet shall be installed near the equipment and shall be easily accessible.
‐ Use only power supplies listed in the user instructions.
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for
information regarding the collection systems available.
CAUTION
‐ RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT
TYPE.
‐ DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
www.wintop.com
Printed in China
27
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project