Sennheiser | L151-10 | User manual | Infrared System Package


Add to my manuals
3 Pages

advertisement

Sennheiser | L151-10 | User manual | Infrared System Package | Manualzz

SI1015-12500 Dual System Package

3.620"

(91.95 mm)

Wireless | Systems

System Includes:

49.817"

(1265.35 mm)

7.000"

(177.80 mm)

2.360"

(59.94 mm)

72.000"

(1828.80 mm)

(2) SZI1029—Emitter panel for single, dual or multi channel use

(2) WM1—Wall/ceiling mount with 5/8” thread for mounting 2 or more SZI1015 or SZI1029

6.660"

(169.16 mm)

(1) SZA1060—Terminating resistor

RF Output 1

(XLR-3F)

Audio Input B

Audio Input A

(XLR-3F)

ON/OFF

Switch

10.350"

(262.89 mm)

9.680"

(2) L151-10—Charging unit with power supply

RF Output

Termninal 1

DC Output

Termninal 1

RF Output

Termninal 2

DC Output

Termninal 2

DC Input Socket

(For NT1015-120)

3.318

Strain Relief

"

(84.28 mm)

Level Control A

Level Control B

1.688"

(42.88 mm)

(1) NT2013-120—Power supply for (2) to (5) L151-10 charging units

Channel Selector Switch

Convection Cooling Fins

General Description

10.270

"

(260.86 mm)

Sennheiser offers system packages that include all components necessary to configure a complete system. Sennheiser’s Large-Area Infrared Systems provide coverage of 4,000 sq. ft. up to 12,500 sq. ft. in both single and dual channel modes.

The SI1015 modulator and SZI1015 or SZI1029 emitters are the primary compo-

4.970

"

(126.24 mm) nents of the systems. The NT1015-120 will provide power for the SI1015 modulator and up to two SZI1015 or SZI1029 emitters. The SZA1060 terminating resistor

(50 ohm), for the last emitter in a daisy chain, is included for system designs that incorporate daisy chaining of emitters. The GA1031-CC rack adapter allows for

5/8 " External

Thread

IEC Mains Connector MONO/Multi Switch easy mounting of a SI1015 modulator to a 19” rack. The WM1 wall/ceiling mount easily mounts the SZI1015 or SZI1029 emitter panels. The RI250 stethophone

4.571

" infrared receivers are for use with single channel systems operating at 2.3 MHz, and include the BA151 rechargeable battery. Alternatively, for dual channel systems, the HDI302 stethophone infrared receiver is for use with systems operating

5/8 " Thread for mounting at 2.3/2.8 MHz, and also includes the BA151 rechargeable battery. The BA151 rechargeable batteries can be conveniently recharged with the L151-10 charging unit(s) with the NT92-120 power supply. In addition, the NT2013-120 will power two to five L151-10 charging units.

2.724

"

(69.19 mm)

Adjusting

Knob ø .161

(4.09 mm)

SI1015

ø .743

(44.27 mm)

Mounting Plate

ø.251

ø .1242

(31.55 mm)

5.286"

(134.26 mm)

Replaceable

Ear Cushions

ø.752

(19.10 mm)

49.817"

(1265.35 mm)

3.620"

(91.95 mm)

7.000"

(177.80 mm)

2.360"

(59.94 mm)

Power Supply

NT1015–120

9.040"

(229.62 mm)

72.000"

(1828.80 mm)

(Behind plastic cover)

Power Cord

1.467"

(37.26 mm)

7.390"

(187.71 mm)

Inserted BA151

Rechargeable

Battery Channel Selector Switch

6.660"

(169.16 mm)

ON/OFF Volume Control

RF Output 2

(BNC)

RF Output 1

(BNC)

RF Output

Termninal 1

DC Output

Termninal 1

(XLR-3F)

Audio Input B

RF Output

Termninal 2

DC Output

Termninal 2

Audio Input A

(XLR-3F)

DC Input Socket

(For NT1015-120)

Cable Grip

Strain Relief

ON/OFF

Switch

10.350"

(262.89 mm)

9.680"

(245.87 mm)

Level Control A

Level Control B

1.688"

(42.88 mm)

IR Monitoring Diodes

Channel Selector Switch

SI1015–Rack mountable, half rack, two channel modulator. Operates at

2.3/2.8 MHz. NT1015-120 power supply required.

* Illustrations do not show NT1015-120 power supply, GA1031-CC rack adapter, SZA1060 terminating resistor, NT2013-120 power supply.

CBinder - Information Systems.indd 33

SI1015

SZI1029

WM1

HDI302

L151–10NT

LED Indicator

Trickle Charge

(Green)

Button:

Press to begin

10 HR charge cycle

LED Indicator

Charge (Red)

Charging for

RI250, HDI302

Infrared Receivers

(Up to ten)

1.500"

(38.10 mm)

SI1015-12500

Dual

11/11/08 11:50:00 AM

74.000"

(1879.60 mm)

2 Pin Texas Connector

NT92–120 Power Supply

13.000"

(330.20 mm)

LED Indicators

Bright=Normal charge

Dim=Trickle charge

5.450"

(138.43 mm)

Charging for

BA151 Battery

(Up to ten)

SI1015-12500 Dual System Package

SZI1029

3.318

"

(84.28 mm)

Convection Cooling Fins

WM1

Ratchet Adjustment

For Angle

5/8 " External

Thread

10.270

"

(260.86 mm)

IR Transmission Diodes

(behind cover)

4.571

"

(116.10 mm)

ø 1.936

(49.17 mm)

4.970

"

(126.24 mm)

RF Output (BNC)

MONO/Multi Switch

RF Input (BNC)

NEED TEXT

HDI302

ø.251

(6.38 mm)

Screw Holes

5.286"

(134.26 mm)

Replaceable

Ear Cushions

IEC Mains Connector

5/8 " Thread for mounting

(3/8" X 1/2" Adapters included)

ø.752

(19.10 mm)

7.390"

(187.71 mm)

Two IR

Receiving Diodes

(Behind plastic cover)

1.467"

(37.26 mm)

Inserted BA151

Rechargeable

Battery Channel Selector Switch

ON/OFF Volume Control

HDI302–Stereo/two channel stethophone infrared receiver with squelch for systems operating at 2.3/2.8 MHz. Includes one BA151 rechargeable battery. (1.6 oz)

2.724

"

(69.19 mm)

Adjusting

Knob ø .161

(4.09 mm)

ø .743

(44.27 mm)

Mounting Plate

ø .1242

(31.55 mm)

WM1–Wall/ceiling mount with 5/8" thread for mounting 2 or more

SI30 or SZI30.

L151-10NT

74.000"

(1879.60 mm)

2 Pin Texas Connector

NT92–120 Power Supply

13.000"

(330.20 mm)

LED Indicator

Trickle Charge

(Green)

Button:

Press to begin

10 HR charge cycle

LED Indicator

Charge (Red)

Charging for

RI250, HDI302

Infrared Receivers

(Up to ten)

1.500"

(38.10 mm)

LED Indicators

Bright=Normal charge

Dim=Trickle charge

5.450"

(138.43 mm)

Charging for

BA151 Battery

(Up to ten)

L151-10/NT–Charging unit with power supply that charges either 10

BA151 rechargeable batteries or 10 RI250 infrared receivers

CBinder - Information Systems.indd 34 11/11/08 11:50:02 AM

SI1015-12500 Dual System Package

Architects Specifications

SI1015-12500 Dual

The infrared system shall be modular and provide coverage for up to 12500 square feet in dual channel mode.

The SI1015 modulator must utilize the higher sub-carrier frequencies of 2.3 and 2.8 MHz for single, two channel or stereo operation with an AF frequency response of 50-15,000 Hz. It must be rack-mountable and have two monitoring diodes for the technician. It must accept line level audio input via XLR connector. It must be easy to install using barrier strip with RF and DC outputs for connecting to emitters; and, alternatively, BNC connectors for connecting the RF signal only. It must have AF level controls with LED’s indicating peak volumes.

The power supply NT1015-120 shall provide power for one SI1015 emitter and shall have an input voltage of 100-240 V (1.3 A), an output voltage of approx. 29 V and an output current of 1.7 A.

The GA 1031-CC rack adapter is capable of mounting an individual SI 1015 modulator to a 19" rack.

The SI1015, SZI1015 and SZI1029 shall be wall or ceiling mountable via a mounting clamp with 5/8" external male thread, and the mounting plate shall have a diameter of 1 5/8".

The stethophone shall be a two channel IR receiver with the following: wideband FM, stereo modulation, 2.3 and 2.8 MHz carrier frequencies, 18-18,000

Hz AF frequency response, greater than 1% THD, typ. 65 dB Signal-to-noise ratio, approx. 110 dB max. SPL, approx. 5 hours operating time, and a weight of approx. 1.58 oz. (including battery pack). The stethophone shall be a Sennheiser HDI302. The receivers shall contain a rechargeable Nickel Metal

Hydride battery, which can easily be recharged with the L151-10 charging unit for up to ten rechargeable batteries. The NT2013-120 power supply is capable of powering two to five of the L151-10 charging units.

The SZI1029 shall be an infrared high power radiator with RF input for wide and narrow-band signals. Carrier frequency band extends to 6 MHz RF input

(50 mV to 3V) via BNC socket, RF output via BNC socket. The unit shall offer excellent reliability due to 12 independent diode groups with malfunction indicator. The unit shall offer a 90-280 V AC power supply and weigh approx. 4 lbs. The unit shall be a Sennheiser SZI1029.

The SZA1060 shall weigh 1.0 oz and be a 50 ohm terminating resistor for the last emitter in a daisy chain.

Limited Product Warranty/Service

Sennheiser Electronic Corporation extends the following limited product warranty for Sennheiser products:

The warranty period for all covered Sennheiser products is two years from the date of purchase. Not covered by this warranty are accessories and other consumables; for example, items of wear and tear, such as cables. During the warranty period, Sennheiser Electronic Corporation warrants that the Sennheiser equipment will be free from defects in materials and workmanship used in making the product. Abnormal conditions, deliberate abuse and damage due to accidents, operator’s error, or unauthorized service attempts are excluded from any warranty claims.

Under this warranty, Sennheiser Electronic Corporation will repair, or at its option, replace free of charge the covered defective Sennheiser product, provided it is returned

(postage paid, with proof of purchase from the original seller) to a Sennheiser Service Facility. Products should be returned in their original package, or otherwise suitably protected to avoid shipping damage. Either product registration or a valid, dated proof of purchase is accepted to establish the warranty period. The Sennheiser Service

Department will be the sole authority to determine the validity of all warranty issues.

This Limited Product Warranty is Sennheiser Electronic Corporation’s only warranty, and the customer’s only remedy concerning Sennheiser products. All other representations and warranties, express or implied, written or oral, including, but not limited to, any warranties of merchantability, fitness for a particular purpose, or non-infringement, are expressly excluded. As a result, except as set forth in the previous paragraphs, the product is sold “as-is” and the customer is assuming the entire risk as to the product’s suitability for his needs, its quality and its performance.

In no event will Sennheiser Electronic Corporation be liable for direct, indirect, special, incidental or consequential damages resulting from any defect in the product or from its use, even if advised of the possibility of such damages.

CBinder - Information Systems.indd 35

Sennheiser Electronic Corporation • 1 Enterprise Drive • Old Lyme, CT 06371

11/11/08 11:50:02 AM

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement