Sartorius Basic lite Operating instructions
Sartorius Basic lite is a series of precision balances designed for a variety of weighing tasks. They offer capacities ranging from 0.1 mg to 12 kg, making them suitable for everything from laboratory applications to everyday use. With features like fast response times, easy operation, and stable weighing results, the Basic lite series provides reliable and accurate measurements.
Advertisement
Advertisement
Operating Instructions
Sartorius Basic lite
Sartorius Gem lite
Electronic Precision Balances and Precious Metal Scales
98648-008-55
Practical Use Contents
The Basic lite Series and Gem lite Series from Sartorius offer precision balances/ scales with capacities ranging from
0.1 mg to 12 kg.
These balances/scales meet the highest requirements on the accuracy and reliability of weighing results through the following features:
– Efficient filtering-out of unfavorable ambient conditions such as vibrations, drafts, etc.
– Stable and reproducible results
– Rugged, durable weighing system
Basic lite balances and Gem lite scales save work and speed up simple routine applications through:
– Ultrafast response times
– Easy operation
You can also choose from the following extra functions for simple applications:
– Toggling between weight units
– Net-total formulation (tare memory)
– Counting
– Weighing in percent
– Averaging
Warning and Safety Information
Read these operating instructions thoroughly before using your balance/ scale to prevent damage to the equipment. Keep these instructions in a safe place.
Follow the instructions below to ensure safe and trouble-free operation of your balance/scale:
!
Make sure that the voltage rating printed on the AC adapter is identical to your local line voltage
!
Use only a commercially available
9-volt battery or rechargeable battery
2
2 Practical Use
2 Contents
2 Warning and Safety Information
3 Getting Started
Operating the Balance/Scale
8 Basic Weighing Function
9 Calibration/Adjustment
Application Programs
10 Counting
12 Weighing in Percent
14 Weigh Averaging
16 Net-Total Formulation/
Second Tare Memory
17 Toggle Between Weighing Units
Configuring the Balance/Scale
18 Setting the Parameters (Menu Codes)
19 Balance/Scale Operating Menu
(Overview)
20 Error Codes
21 Care and Maintenance
22 Instructions for Recycling
Overview
23 Specifications
28 Accessories (Options)
29 C Marking
!
Do not use this balance/scale in a hazardous area/location
– The only way to turn the power off completely is to disconnect the AC adapter
– Connect only Sartorius accessories and options, as these are optimally designed for use with your balance/scale.
– Protect the AC adapter from contact with liquid.
Do not open the balance/scale housing.
If the seal is broken, this will result in forfeiture of all claims under the manufacturer’s warranty.
Getting Started
Warranty
Do not miss out on the benefits of our full warranty. Please contact your local
Sartorius office or dealer for further information. Complete the warranty registration card, if available indicating the date of installation, and return the card to your Sartorius office or dealer.
Storage and Shipping Conditions
Do not expose the balance/scale to shocks, vibration, moisture or extreme temperatures.
Unpacking the Balance/Scale
§ After unpacking the balance/scale, check it immediately for any visible damage as a result of rough handling during shipment.
$ If you see any sign of damage, proceed as directed in the chapter entitled “Care and Maintenance,” under the section on
“Safety Inspection.”
Save the box and all parts of the packaging until you have successfully installed your balance/scale. Only the original packaging provides the best protection for shipment. Before packing your balance/scale, unplug all connected cables to prevent dama
ge.
Equipment Supplied
The equipment supplied includes the components listed below:
BL210S, BL120S, BL60S, GC503, GC103
– Balance/scale
– Weighing pan
– Pan support
– Shield ring
– Shield plate
– Dust cover
– AC adapter
– Gem tray (only with GC models)
– Calibration weight 100 g, F1
(only with model GC503)
BL150S
– Balance/scale
– Weighing pan
– Pan support
– Glass draft shield with cover
– AC adapter
Balances/scales with a readability of >0.01g
– Balance/scale
– Weighing pan
– Pan support (only on models with a round weighing pan)
– AC adapter
3
Installation Instructions
Your balance/scale is designed to provide reliable weighing results under normal ambient conditions. When choosing a location to set up your balance/scale, observe the following so that you will be able to work with added speed and accuracy:
– Set up the balance/scale on a stable, even surface
– Avoid placing the balance/scale in close proximity to a heater or otherwise exposing the balance/scale to heat or direct sunlight
– Protect the balance/scale from drafts that come from open windows or doors
– Avoid exposing the balance/scale to extreme vibrations during weighing
– Protect the balance/scale from aggressive chemical vapors
– Do not expose the balance/scale to extreme moisture over long periods
Conditioning the Balance/Scale:
Moisture in the air can condense on the surfaces of a cold balance/ scale whenever it is brought into a substantially warmer place. If you transfer the balance/scale to a warmer area, make sure to condition it for about 2 hours at room temperature, leaving it unplugged from AC power.
Information on Radio Frequency Interference
Warning!
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio communications.
It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference, when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user, at his own expense, will be required to take whatever measures may be required to correct the interference.
4
Setting up the Balance/Scale
Balances/Scales with an Analytical Draft Shield
Chamber:
§ Place the components listed below inside the chamber in the order given:
– Shield plate
– Shield ring
– Pan support
– Weighing pan
– Gem tray (only with GC models)
Balances/Scales with a Glass Draft Shield:
§ Place the components listed below inside the chamber in the order given:
– Draft shield base – place it on the balance/scale so that the edge for fitting the glass draft shield faces upwards and turn it until it is firmly in place
– Pan support
– Weighing pan
– Glass draft shield
– Draft shield cover – place it on the balance/scale so that the edge faces downwards
Balances/Scales with a Round Weighing Pan
§ Place the components listed below inside the chamber in the order given:
– Pan support
– Weighing pan
Balances/Scales with a Rectangular Weighing Pan:
§ Place the weighing pan on the balance/scale
5
6
Connecting the Balance/Scale to AC Power/
Safety Precautions
Use only original Sartorius AC adapters:
– for Europe: 6971948 – for the RSA: 6971949
– for the U.S.: 6971947 – for Australia: 6971950
§ Insert the right-angle plug into the jack
§ The AC adapter rated to Class 2 can be plugged into any wall outlet without requiring any additional safety precautions
The ground is connected to the balance/scale housing, which can be additionally grounded for operation.
Using a Non-Rechargeable/Rechargeable Battery
(not for models BL210S, BL120S, BL60S, BL150S,
BL1500S, GC503, GC103, GM1502, GM2202,
GM1202)
$ A non-rechargeable or rechargeable battery is not included with the equipment supplied
!Use only a commercially available non-rechargeable or rechargeable 9-volt battery
!When using a rechargeable battery, always use an external charger to recharge the battery
§ Lay the balance/scale on its side
§ Open the battery compartment:
Lift the compartment cover
§ Insert the 9-volt (rechargeable) battery in the compartment
$ Make sure to connect the positive and negative poles correctly
!All used batteries are classified as waste that requires special handling (not “household” waste). Dispose of rechargeable batteries in accordance with the applicable special waste disposal regulations.
§ Close the battery compartment:
Press down on the cover until it clicks into place
Selecting the Line Voltage (Mains Voltage)
Use the following original AC adapters for selecting the line voltage:
– AC adapter TNG8, order no. 6971951 (universal) or
– AC adapter TNG8, order no. 6971952 (for the U.K.)
● Use the switch to toggle between 230 V and 115 V
Leveling the Balance/Scale
(only for models BL210S, BL120S, BL60S, BL150S,
BL1500S, GC503, GC103, GM1502, GM2202,
GM1202)
Level the balance/scale any time you set it up in a new location. Use only the 2 front feet of the balance/scale for leveling.
§ Turn the 2 rear feet until they are in position
(only on models BL1500S and GM1502, GM2202 and GM1202)
§ Turn the 2 front feet as shown here in the illustration until the air bubble is centered in the level indicator
> In most cases, this will require several adjustment steps
Anti-theft Locking Device
To protect against theft, use the mounting lug on the rear panel of the balance/scale.
● Secure the balance/scale at the place of installation, for example with a chain or a lock
7
8
Operating the Balance/Scale
Basic Weighing Function
Available Features
– Taring the balance/scale
You can tare the balance/scale within the entire weighing range.
Preparation
§ Turn on the balance/scale: Press e
§ To change configurations: See the chapter entitled “Configuring the Balance/Scale”
§ To load factory-set configurations: See “Configuring the Balance/Scale,” parameter 9 – 1
$ To tare the balance/scale: Press t
Additional Functions
§ To turn off the balance/scale: Press e
Example
Basic weighing
Menu code settings: Factory-set codes
Step Key (or instruction) Display/Printout
1. Turn on the balance/scale
Self-test is performed e
2. Place container on balance/ scale (here: 52 g)
3. Tare the balance/scale
4. Place sample in container on balance/scale (here: 150.2 g) t
+ 52.0 g
+ 0.0 g
+ 150.2 g
Calibration/Adjustment*
Always calibrate/adjust the balance/scale after setting it up in a new location.
Available Features
Calibration/adjustment can only be performed when
– there is no load on the balance/scale,
– the balance/scale is tared,
– the internal signal is stable.
If these conditions are not met, an error message is displayed.
The weight required for calibration/adjustment is displayed (see “Accessories” for calibration weights; for model GC503 see “Equipment Supplied”).
On Basic lite balances, calibration/adjustment can be performed with any of three weight units: g, kg**, or lb (menu code 1. 4. x)
Factory setting: Grams (menu code 1. 4. 1)
Example
Calibrate the balance/scale
Menu code settings: Factory-set codes
Step Key (or instruction) Display/Printout
1. Turn on the balance/scale e
2. Tare the balance/scale t
3. Begin calibration
Calibration weight is displayed without weight unit (here: 1000 g) t >2 sec.
4. Place the indicated calibration weight on the balance/scale
After calibration, the calibration weight is displayed with wt. unit
5. Remove the calibration weight
+
+
0.0 g
1000.0
1000.0
1000.0 g
0.0 g
* = “Calibration” technically means to determine the difference between the balance/scale readout and the actual weight on the pan to determine the accuracy.
Adjustment means to bring a balance/scale into the state of accuracy required for its use.
Therefore, “calibration,” as used in this manual, actually means “adjustment.”
**= not on models with a readability of 0.1 mg
9
10
Application Programs
Counting
Purpose
With the Counting program you can determine the number of parts that each have approximately equal weight.
Available Features
– Store the current weight value to have it loaded as the preset reference sample quantity next time you initialize the Counting application
– The reference sample quantity can be changed in the operating menu:
See “Configuring the Balance/Scale”
– The average piece weight is automatically output via the optional data interface port after initialization, if the menu code for “Printout with data ID codes” is set
– Press v to toggle the display between piece count and weight
Factory Settings
Reference sample quantity: 10 (menu code 3. 3. 2)
Preparation
§ Configure the Counting application in the operating menu:
See “Configuring the Balance/Scale”
Menu code 2. 1. 4 Counting
§ Reference sample quantity:
Menu code 3. 3. 1
Menu code 3. 3. 2
Menu code 3. 3. 3
Menu code 3. 3. 4
Menu code 3. 3. 5
5 pcs
10 pcs
20 pcs
50 pcs
100 pcs
See also “Configuring the Balance/Scale”
Example
Determine an unknown piece count; weigh the preset reference sample quantity
Settings (changes in the factory settings required for this example):
Menu: Application program: Counting (menu code 2. 1. 4)
Reference sample quantity: 20 pcs (menu code 3. 3. 3)
Key (or instruction) Display/Printout Step
1
1. Turn on the balance/scale e t v >2 sec.
0.0 g ref 20 (briefly)
1 2. Tare the balance/scale
1 3. Display the reference sample quantity (here: 20 pcs)
1 4. Place the reference sample quantity (20 pcs) on the balance/scale (here: 66 g)
1 5. Start the application; if the print format is set to include data ID codes, the following is printed:
1 6. Weigh uncounted parts
(here: 174 pcs)
1 7. Display weight
1 8. Display quantity
1 9. Unload the balance/scale v v v
+
+
66.0 g
20 pcs wRef + 3.300 g
+
+
+
174 pcs
574.2 g
174 pcs
0 pcs c 10. Delete the reference value
11. Repeat the procedure starting from step 6, if desired.
11
12
Weighing in Percent
Purpose
This application program allows you to obtain weight readouts in percent which are in proportion to a reference weight.
Available Features
– Store the current weight value to have it loaded as the preset reference percentage next time you initialize the Weighing in Percent application
– The reference percentage can be changed in the operating menu:
See “Configuring the Balance/Scale”
– The reference percentage is automatically output via the optional data interface port after initialization, if the menu code for “Printout with data ID codes” is set
– Press v to toggle the display between percentage and weight
Factory Settings
Reference percentage: 10 (menu code 3. 3. 2)
Preparation
§ Configure the Weighing in Percent application in the operating menu:
See “Configuring the Balance/Scale”
Menu code 2. 1. 5 Weighing in percent
§ Reference percentage:
Menu code 3. 3. 1
Menu code 3. 3. 2
Menu code 3. 3. 3
Menu code 3. 3. 4
5 %
10 %
20 %
50 %
Menu code 3. 3. 5 100 %
See also “Configuring the Balance/Scale”
Example
Determine an unknown percentage; store the weight on the balance/scale as a reference percentage
Settings (changes in the factory settings required for this example):
Menu: Application program: Weighing in percent (menu code 2. 1. 5)
Menu: Reference percentage 100 % (menu code 3. 3. 5)
Step Key (or instruction) Display/Printout
1 1. Turn on the balance/scale e
1 2. Tare the balance/scale
1 3. Display the reference percentage
1 4. Place the reference weight for 100% on the balance/scale
(here: 222.5 g)
1 5. Start application; if the print format is set to include data
ID codes, the following is printed:
1 6. Place an unknown weight on the balance/scale
(here: 322.5 g)
1 7. Display weight
1 8. Display percentage
1 9. Unload the balance/scale t v > 2 sec.
v v v
+ 222.5 g
+
Wxx% + 222.500 g
+ 144.94 %
+
+
0.0 g ref 100
100.00 %
322.5 g
144.94 %
0.00 % c 10. Delete the reference percentage
11. Repeat the procedure starting from step 6, if desired.
13
14
Weigh Averaging
Purpose
Use this program to determine weights under unstable ambient conditions. In this program, the balance/scale calculates the weight as the average value from a defined number of individual weighing operations. These weighing operations are also known as “subweighing operations” or “subweighs.”
Available Features
– The measured result displayed is the arithmetic mean shown in the selected weight unit; a triangle indicates that this is a calculated value
– You can set the number of subweighing operations performed in the operating menu:
See “Configuring the Balance/Scale”
– Press v for at least 2 sec. to display the preset number of subweighing operations
– Press v to toggle the display between the calculated result and the weight
Factory Settings
Number of subweighs for averaging: 10 (3. 3. 2)
Preparation
§ Configure the Weigh Averaging application in the operating menu:
See “Configuring the Balance/Scale”
Menu code 2. 1.12
Averaging
– Number of subweighs for weigh averaging:
3. 3. 1 5 subweighs
3. 3. 2
3. 3. 3
10 subweighs
20 subweighs
3. 3. 4 50 subweighs
3. 3. 5 100 subweighs
See also “Configuring the Balance/Scale”
Example
Determine the weight of a sample in extremely unstable ambient conditions by calculating the average of 10 subweighing operations.
Settings (changes in the factory settings required for this example):
Menu: Application program: Weigh Averaging (menu code 2. 1.12)
Step Key (or instruction) Display/Printout
1. Turn on the balance/scale e
2. Tare the balance/scale
3. Display the number of subweighs (here: 10)
4. Place sample on the balance/ scale (weight readout fluctuates; here: about 275 g)
5. Start measurement t v >2 sec.
v ref
0.0 g
10 (briefly)
+ 8888
+ 8888
10
9
8
...
1
+ 275.5 g G
After 10 subweighs
If the print format is set to include data ID codes, the following is printed:
6. Unload the balance/scale
RES + 275.5 g
+ 275.5 g G
(stable display) c 7. Delete the result
8. Repeat the procedure starting from step 4, if desired.
15
Net-Total Formulation/Second Tare Memory
With this application program you can weigh in components for formulation of a mixture.
Preparation
Configure the Net-Total Formulation/Second Tare Memory application in the operating menu: See “Configuring the Balance/Scale” Menu code 2.1.3
Example
Step Key (or instruction) Display/Printout
1. Turn on the balance/scale e
2. Place an empty container on the balance/scale
+ 65.0 g
3. Tare the balance/scale
4. Add the first component t
+ 120,5 g
5. Store the first component weight
If the print format is set to include data ID codes, the following is printed:
6. Add the next component
7. Store the 2nd component weight
8. Add further components, if desired
9. Display total weight and fill to desired final weight v 0.0 g
NET
N1 + 120.5 g
+ 70,5 g
0.0 g
NET v
As described for steps 5 and 6 c + 191,0 g
16
Toggle Between Weight Units
With this application program you can toggle the display of a weight value back and forth between two weight units.
Configure the “Toggle Weight Units” application in the operating menu:
See “Configuring the Balance/Scale,” menu code 2.1. 2 Toggle weight units (Factory setting on Gem lite models)
Menu code
1. 7. 1
1. 7. 13
1. 7. 14
1. 7. 15
1. 7. 16
1. 7. 17
1. 7. 18
1. 7. 19
1. 7. 20
1. 7. 2 o
1. 7. 3 1
)
1. 7. 4 2
)
1. 7. 5
1. 7. 6
1. 7. 7
1. 7. 8
1. 7. 9
1. 7. 10
1. 7. 11
1. 7. 12
1. 7. 22
3. 1. 1
3. 1. 13
3. 1. 14
3. 1. 15
3. 1. 16
3. 1. 17
3. 1. 18
3. 1. 19
3. 1. 20
3. 1. 22
3. 1. 2 o
3. 1. 3 1
)
3. 1. 4
3. 1. 5
3. 1. 6
3. 1. 7 3 )
3. 1. 8
3. 1. 9
3. 1. 10
3. 1. 11
3. 1. 12
Unit
Taiwanese taels 4 )
(only selectable on Gem lite scales)
Grams
Kilograms
Carats
Pounds
Ounces
Troy ounces
Hong Kong taels
Singapore taels
Taiwanese taels
Grains
Pennyweights
Milligrams
Parts per pound
Chinese taels
Mommes
Austrian carats
Tola
Baht
Mesghal lb/oz – Gem lite scales only
Conversion factor
0.02666666000
Abbr. on printout o
1.00000000000
0.00100000000
5.00000000000
0.00220462260
0.03527396200
0.03215074700
0.02671725000
0.02645544638
0.02666666000
15.43235835000
0.64301493100
GN dwt
1000.00000000000
mg
1.12876677120
/lb
0.02645547175
0.26670000000
5.00000000000
tlc mom
K
0.08573333810
0.06578947437
0.21700000000
0.03527396200
tol bat
MS o g ozt tlh tls tlt kg ct lb oz
ο = Factory setting
1 ) = not for models with a readability of ≤ 0.2 mg
2 ) = Factory setting only for model GC503
3 ) = Factory setting only for GM models
4 ) = Readability in increments of 1 digit
Function
● To toggle the display between the 1st and 2nd weight units:
Press the v key
17
Configuring the Balance/Scale
Setting the Parameters (Menu Codes)
You can configure your Basic lite balance or Gem lite scale to meet individual requirements by selecting from the parameters available in the menu.
Example: Adapt the balance/scale to unstable ambient conditions:
Menu code 1 1 4
Step Key (or instruction) Display
1. Turn off the balance/scale
2. Turn the balance/scale back on; while all segments are displayed:
$ To navigate within a menu level; the last menu option is followed by the first option e e t briefly t repeatedly
1.
2.
...
9.
1.
3. Select the 2nd menu level
4. Select the 3rd menu level
5. In Menu Level 3:
Select the desired option
6. Confirm new setting; the “o” indicates the currently set option
$ Select the next menu level
(here: move from the 3rd to the 1st level)
$ Set other menu codes, if desired
7. Store parameter settings and exit operating menu or
$ Exit operating menu without storing changes
> Restart the application p p t repeatedly p for 2 sec. p p, t t for 2 sec.
e
1. 1.
1. 1. 2 o
1. 1. 4
1. 1. 4 o
1.
0.0 g
18
Balance/Scale Operating Menu (Overview)
ο Factory setting
√ User setting
Menu
Menu level
1
1. Balance/ scale functions
2. Application programs
3. Application parameters
Menu level
2
1.1. Adapt filter
1.3. Stability range
1.4. Weight unit for calibration weight**
1.6. Auto zero
1.7. Weight unit 1
1.8. Display accuracy
2.1. Program selection
3.1. Weight unit 2
3.2. Display accuracy
3.3. Reference qty or %
Menu level
3
Factory setting
Menu level
4
1.1.1
1.1.2
1.1.3
1.1.4
Minimum vibration
ο Normal vibration
Strong vibration
Extreme vibration
1.3.1
1.3.2
1.3.3
1.3.4
1.3.5
1.4.1
1.4.2
1.4.3
1/4 digit
1/2 digit
1 digit
ο 2 digits
4 digits
ο Grams
Kilograms
Pounds
1 )
1.6.1
1.6.2
ο On
Off
See “Toggle between Weight Units”
1.8.1
1.8.3
ο Standard resolution
Increased resolution see the desired application program description see “Toggle between Weight Units”
3.2.1
3.2.3
ο Standard resolution
Increased resolution see the desired application program description
5. through 7. applies only if an interface is installed; see the corresponding instructions
8. Extra functions 8.1. Menu 8.1.1
8.1.2
ο Parameter settings: alterable
Parameter settings: read only
9. Reset menu
8.2. External switch function applies only if an interface is installed; see the corresponding instructions
8.3. Power-on mode 8.3.1
8.3.2
Off/on (battery shuts off automatically after 3 min)
ο Standby/on
9.– Factory settings 9.– 1 Reset
9.– 2 ο Do not reset
* = only for GM models
** = only for BL models
1 ) = not for models with a readability of 0.1 mg⁄
19
Error Codes
Error codes are shown on the main display for approx. 2 seconds, after which the program automatically returns to the weighing mode.
Display Cause Solution
No segments appear on the display h l e 01
No AC power is available Check the AC power supply
The AC adapter is not plugged in Plug in the AC adapter
Battery is dead Replace the battery
Recharge the battery using an external charger
The load exceeds the balance/scale capacity
Unload the balance/scale
The weighing pan is not in place
Something is touching the weighing pan
Display capacity exceeded:
Value to be output cannot be shown on the display
Place the weighing pan on the balance/scale
Move the object that is touching the weighing pan
Decrease the weight on the balance/scale e 02 e 09 e 10 e 11 e 22
Calibration parameter requirement not met; e.g.:
– balance/scale not zeroed
– balance/scale is loaded
Calibrate only when zero is displayed
Press t to tare the balance/scale
Unload the balance/scale
When gross value < zero, no tare Tare the balance/scale
The t key is blocked when Press c to clear the there is data in the second tare tare memory and release the memory (net-total) – only 1 tare function can be used at a time tare key
Value input is not allowed for second tare memory
Press t
Weight is too light or there is no sample on the balance/scale
Increase the reference quantity or sample amount e 30 Interface port for printer output is blocked
Max. weighing capacity The balance/scale was is less than indicated turned on without the under “Specifications” weighing pan in place
Contact your local Sartorius
Service Center
Place the weighing pan on the balance/scale and press e to turn the balance/scale back on
The weight readout is obviously wrong
The balance/scale has not been calibrated/adjusted
The balance/scale was not tared before weighing
Calibrate/adjust the balance/ scale
Tare before weighing
If any other errors occur, please contact your local Sartorius Service Center.
20
Care and Maintenance
Service
Regular servicing by a Sartorius technician will extend the service life of your balance/scale and ensure its continued weighing accuracy. Sartorius can offer you service contracts, with your choice of regular maintenance intervals ranging from 1 month to 2 years. The frequency of the maintenance intervals depends on the user’s operating conditions and the tolerance limits.
Repairs
Repair work must be performed by trained service technicians. Any attempt by untrained persons to perform repairs may lead to hazards for the user.
Cleaning
!Disconnect the balance/scale from the AC adapter and unplug any interface cables that are connected to the balance/scale
!Make sure that no liquid enters the balance/scale housing
!Do not use any aggressive cleaning agents (solvents or similar agents)
§ Clean the balance/scale using a piece of cloth which has been wet with a mild detergent (soap)
§ After cleaning, wipe down the balance/scale with a soft, dry cloth
Removing and Cleaning the Weighing Pan:
● Lift up and remove the weighing pan together with the pan support by gripping them from under the shield ring. Make sure that you do not damage the weighing system in doing so.
21
22
Safety Inspection
If there is any indication that safe operation of the balance/scale with the AC adapter is no longer warranted:
§ Turn off the power and disconnect the equipment from AC power immediately
> Lock the equipment in a secure place to ensure that it cannot be used for the time being
Safe operation of the balance/scale with the AC adapter is no longer ensured when:
– there is visible damage to the AC adapter
– the AC adapter no longer functions properly
– The AC adapter has been stored for a relatively long period under unfavorable conditions
In this case, notify your nearest Sartorius Service
Center or the International Technical Support Unit based in Goettingen, Germany. Maintenance and repair work may only be performed by service technicians who are authorized by Sartorius and who
– have access to the required maintenance manuals
– have attended the relevant service training courses
Instructions for Recycling the Packaging
To ensure adequate protection for safe shipment, your balance/scale has been packaged to the extent necessary using environmentally friendly materials.
After successful installation of the balance/scale, you should return this packaging for recycling because it is a valuable source of secondary raw material.
For information on recycling options, including recycling of old weighing equipment, contact your municipal waste disposal center or local recycling depot.
Overview
Specifications
Basic lite Series
Model BL210S BL120S BL60S
Weighing capacity
Readability
Tare range (subtractive)
Repeatability
Linearity
Operating temperature range
Allowable ambient operating temperature
Sensitivity drift within
+10…+30°C
Response time (average)
Adaptation to ambient conditions
Display update (depends on the filter level selected)
External calibration weight
(of at least accuracy class…)
Net weight, approx.
Pan size g mg g s
210
0.1
210
<±mg 0.1
<±mg 0.2
120
0.1
120
0.1
0.2
+10…+30°C (50°F–86°F)
+5…+40°C
<±/K 2·10 –6
3
2·10
3
–6
60
0.1
60
0.1
0.2
2·10
3
–6
By selection of 1 of 4 optimized filter levels
Weighing chamber height
Dimensions (WxDxH)
AC power source/power requirements
Frequency
Power requirements, direct current V
Power consumption (average) W
Hours of operation with the
YRB08Z rechargeable battery pack h s 0.1–0.4
g 200 (E2) lb0.4
kg/lb3.0/6.6
mm 80 Ø inches 3.3 Ø mm 200 inches 7.9
mm 189x251x299 inches 7.4x9.9x11.8
100 (E2)
0.2
3.0/6.6
80 Ø
3.3 Ø
200
7.9
AC adapter, 230 V or 115 V, +15%…–20%
48–60 Hz
10 to 20
1
20
1
20
1
20
50 (E2)
0.1
3.0/6.6
80 Ø
3.3 Ø
200
7.9
23
Gem lite Series
Model GC503 GC103 GM1205
Weighing capacity
Readability
Tare range (subtractive)
Repeatability
505 ct/101 g 105 ct/21 g 1200 g
0.001 ct/0.2 mg 0.001 ct/0.2 mg 50 mg
505 ct/101 g 105 ct/21 g 1200 g
0.001 ct/0.2 mg 0.001 ct/0.2 mg 50 mg
Linearity
Operating temperature range
<±
<± 0.002 ct/0.4 mg 0.002 ct/0.4 mg 100 mg
+10…+30°C
(50°F–86°F)
Allowable ambient operating temperature +5…+40°C
Sensitivity drift within
+10…+30°C
Response time (average)
Adaptation to ambient conditions
Display update (depends on the filter level selected) s
<±/K 2·10 –6 s 3
2·10
3
–6 2·10
2
–5
By selection of 1 of 4 optimized filter levels
0.2–0.4
0.2–0.4
0.2–0.8
External calibration weight
(of at least accuracy class…)
Net weight, approx.
Pan size
Weighing chamber height
Dimensions (WxDxH) g 100 (F1) lb– kg/lb2.8/6.2
mm 80 Ø inches 3.3 Ø mm 133 inches 5.2
mm 189x251x233 inches 7.4x9.9x9.2
20 (F1)
–
2.8/6.2
80 Ø
3.3 Ø
133
5.2
189x251x233
7.4x9.9x9.2
1000 (F2)
–
1.4/3.1
174 x 143
6.9 x 5.6
–
–
189x251x70
7.4x9.9x2.8
AC power source/power requirements
Frequency
Power requirements, direct current
Power consumption (average)
AC adapter, 230 V or 115 V, +15%…–20%
Approx. hours of operation with:
– 9-volt battery, approx.
– fully charged rechargeable battery h h
Hours of operation with the
YRB08Z rechargeable battery pack h
V
W
48–60 Hz
10 to 20
1
–
–
20
1
–
–
20
0.75
11
2.5
25
24
Basic lite Series and Gem lite Series
Model BL150S GM2202 BL1500S, GM1202 BL610,
GM1502 GM612
Weighing capacity
Readability g g
150
0.001
2200
0.01
1500
0.01
Tare range (subtractive) g 150
+5…+40°C
2200 1500
Repeatability
Linearity
Operating temperature range
<±g 0.0015
<±g 0.003
0.03
0.04
0.015
0.03
+10…+30°C (50°F…86°F)
Allowable ambient operating temperature
Sensitivity drift within
+10…+30°C
Response time (average)
<±
/K s
3.3·10
2.5
–6 3.3·10
2.5
–6 3.3·10
2.5
–6
1200
0.01
1200
0.03
0.03
610
0.01
610
0.01
0.02
Adaptation to ambient conditions
Display update (depends on the filter level selected) s
By selection of 1 of 4 optimized filter levels
0.2–0.8
External calibration weight g 100 (F1) 2000 (F1) 1000 (F1) 1000 (F1) 500 (F2)
(of at least accuracy class…) lb* 0.2 – 2 – 1
Net weight, approx.
kg
/lb1.6/3.5
1.4/3.1
1.4/3.1
1.4/3.1
1.1/2.4
Pan size mm 100 Ø inches 3.9 Ø
174x143
6.9x5.6
174x143
6.9x5.6
mm 189x251x70 (7.4x9.9x2.8 inches)
174x143 116 Ø
6.9x5.6
4.6 Ø
Dimensions (WxDxH)
AC power source/power requirements AC adapter, 230 V or 115 V, +15%…– 20%
48–60 Hz Frequency
Power requirements, direct current V 10 to 20
0.75
Power consumption (average) W
Approx. hours of operation with:
– 9-volt battery, approx.
h – – – – 11
– fully charged rechargeable battery
Hours of operation with the
YRB08Z rechargeable battery pack h h
–
25
– –
3.3·10 –6
2.5
–
0.5·10 –5
2
2.5
* = only for BL models
25
Basic lite Series and Gem lite Series
Model BL310, GM212 BL150, BL6100,
GM312 GM152 GM6101
Weighing capacity
Readability
Tare range (subtractive)
Repeatability
Linearity
Operating temperature range
Allowable ambient operating temperature
Sensitivity drift within
+10…+30°C
Response time (average) g g g
310
0.01
310
<±g 0.01
<±g 0.02
210
0.01
210
0.01
0.02
150
0.01
150
0.01
0.02
+10…+30°C (50°F…86°F)
+5…+40°C
6100
0.1
6100
0.1
0.2
<±
/K s h h
1·10 –5
2
2.5
25
1·10 –5
2
2·10 –5
1.5
0.5·10 –5
2
Adaptation to ambient conditions
Display update (depends on the filter level selected)
Pan size s
By selection of 1 of 4 optimized filter levels
0.2–0.8
External calibration weight g 100 (F2) 100 (F2) 100 (M1) 5000 (F2)
(of at least accuracy class…) lb* 0.2 – 0.2 10
Net weight, approx.
kg
/lb1.1/2.4
1.1/2.4
1.1/2.4
1.4/3.1
mm 116 Ø inches 4.6 Ø
116 Ø
4.6 Ø
116 Ø
4.6 Ø mm 189x251x70 (7.4x9.9x2.8 inches)
174x143
6.9x5.6
Dimensions (WxDxH)
AC power source/power requirements AC adapter, 230 V or 115 V, +15%…– 20%
48–60 Hz Frequency
Power requirements, direct current V 10 to 20
0.75
Power consumption (average) W
Approx. hours of operation with:
– 9-volt battery, approx.
h 11
– fully charged rechargeable battery
Hours of operation with the
YRB08Z rechargeable battery pack
*
= only for BL models
26
Basic lite und Gem lite Serie
Model BL3100, BL1500, BL600, BL12 BL6
GM3101 GM1501 GM601
BL3
Weighing capacity
Readability
Tare range (subtractive)
Repeatability
Linearity g g
3100
0.1
1500
0.1
610
0.1
g 3100 1500 610
<±g 0.1
<±g 0.2
0.1
0.2
0.1
0.2
+10…+30°C (50°F…86°F)
12000 6000 3000
1
12
1
2
1
6
1
2
Operating temperature range
Allowable ambient operating temperature +5…+40°C
Sensitivity drift within
+10…+30°C
Response time (average)
Adaptation to ambient conditions
Display update (depends on the filter level selected) s
<±/K 1·10 –5 s 2
2·10
1.5
–5 5·10
1.5
–5 2.5·10
1.5
–5 5·10
1.5
–5
By selection of 1 of 4 optimized filter levels
0.2–0.8
1
3
1
2
10·10
1.5
–5
External calibration weight
(of at least accuracy class…)
Net weight, approx.
Pan size kg lb*
1 (F2)
2 kg/lb1.4/3.1
1 (M1)
2
0.5 (M1) 5 (M1)
1 10
5 (M1)
10
Dimensions (WxDxH)
AC power source/power requirements
Frequency
Power requirements, direct current mm 174x143 (6.9x5.6 inches) mm 189x251x70 (7.4x9.9x2.8 inches)
AC adapter, 230 V or 115 V, +15%…– 20%
48–60 Hz
V 10 to 20
Power consumption (average) W 0.75
Approx. hours of operation with:
– 9-volt battery, approx.
h 11
1 (M1)
2
– fully charged rechargeable battery
Hours of operation with the
YRB08Z rechargeable battery pack h h
2.5
25
* = only for BL models
27
Accessories (Options)
Product Order No.
Interface port, installation kit YDO02BL
Data printer YDP04
Data printer YDP03-0CE with date/time, statistics evaluation and transaction counter functions and LCD (data interface required)
Paper (5 rolls) 6906937
Remote display
(data interface required)
– reflective
– for overhead projectors, transmissive
YRD02Z
YRD13Z
External rechargeable battery pack with external battery charger
YRB08Z
(hours of operation: 20 or 40.
depending on balance/scale model)
SartoConnect data transfer program for interfacing a
Sartorius balance to a PC with a Windows 95/98 or
NT operating system
YSC01L
This software enables you to transfer the data recorded by your balance to any PC application program (e.g., Excel).
Interface cable for connecting a PC; 25-pin
7357312
Universal remote control switch:
(data interface required)
Foot switch with T-connector YFS01
Hand switch with T-connector YHS02
YTC01 T-connector for connecting 2 peripheral devices
(data interface required)
Carrying case
– for models with a readability >1mg
– for models BL210S, BL120S,
BL60S
YDB01BL
YDB02BL
Product Order No.
Dust cover, for use during weighing
– for models with a rectangular weighing pan 6960BL02
– for models with a round weighing pan 6960BL03
Attaching the dust cover to models with a glass draft shield:
– Remove adhesive strip from balance/scale housing
– Place dust cover on balance/scale
– Stick adhesive strip on dust cover
Gem trays
– 300 ml, weight: 86 g, stainless steel
– 270 ml, wt.: 62 g,
137 Ø mm stainless steel
6407
– 1000 ml, wt.: 240 g, stainless steel 641211
– 300 ml, wt.: 22 g, aluminum 69641304
– 110 ml, 90 Ø mm, aluminum YWP02G
YWP03G
Calibration weights
– for BL210S (200 g; E2)
– for BL120S, BL150S,
GC503* (100 g; E2)
– for GC103 (20 g; F1)
– for BL60S (50 g; E2)
– for the BL150, BL310,
YCW5228-00
YCW5128-00
YCW4238-00
YCW4528-00
GM512, GM212, GM312
(100 g; F2) YCW5148-00
– for the BL610, BL600,
GM612, GM601
(500 g; F2)
– for the BL1500S, GM1502,
YCW5548-00
GM1202 (1 kg; F1)
– for the BL1500, BL3100, BL3,
YCW6138-00
GM3101, GM1205,
GM1501 (1 kg; F2) YCW6148-00
– for the GM2202 (2000 g; F1) YCW6238-00
– for the BL6100, BL6, BL12,
GM6101 (5 kg; F1) or alternative
YCW6538-00
YSS653-00
* = F1 100-g weight supplied with the GC503 scale
28
C
29
Sartorius AG
Weender Landstrasse 94–108
37075 Goettingen, Germany
Phone +49.551.308.0
Fax +49.551.308.32 89 www.sartorius.com
Copyright by Sartorius AG,
Goettingen, Germany.
All rights reserved. No part of this publication may be reprinted or translated in any form or by any means without the prior written permission of Sartorius AG.
The status of the information, specifications and illustrations in this manual is indicated by the date given below.
Sartorius AG reserves the right to make changes to the technology, features, specifications and design of the equipment without notice.
Status:
July 2002, Sartorius AG,
Goettingen, Germany
Printed in Germany on paper that has been bleached without any use of chlorine
W8A000 Basiclite/Gemlite · KT
Publication No.: WBL6005-e02076
Download
Advertisement
Key features
Capacity range from 0.1 mg to 12 kg
Ultrafast response times for efficient weighing
Rugged and durable construction for long-lasting use
Filtering of unfavorable ambient conditions for stable results
Easy operation with intuitive controls
Multiple weighing units for versatility
Net-total formulation for precise dosing and mixing
Averaging function for improved accuracy
Frequently asked questions
The maximum capacity varies depending on the model, with options ranging from 0.1 mg to 12 kg.
It features ultrafast response times, ensuring efficient and timely weighing.
Yes, it effectively filters out unfavorable ambient conditions such as vibrations and drafts, contributing to stable and reproducible results.
Yes, it supports multiple weighing units, providing versatility for various applications.
Yes, it includes a net-total formulation function, which is ideal for precise dosing and mixing tasks.