aoyue INT 2702A+ Instruction manual


Add to my manuals
14 Pages

advertisement

aoyue INT 2702A+ Instruction manual | Manualzz

Manufacturer: 

AOYUE TONGYI ELECTRONIC EQUIPMENT FACTORY 

Jishui Industrial Zone, Nantou, Zhongshan City, 

Guangdong Province, P.R.China  http://www.aoyue.com

28 

I

I  NT 

2702 

Lead-Free�

Repairing System

INSTRUCTION MANUAL

Thank you for purchasing Aoyue Int2702 Repairing System. 

It is important to read the manual before using the equipment. 

Please keep manual in accessible place for future reference. 

This manual is designed to familiarize and instruct the technician with the proper operation and maintenance of the equipment. The “Care and Safety Precautions” section explains the hazards of using any type of soldering or reworking device. Please read carefully and observe the guidelines in order to maximize usage and minimize the risk of injury or accidents .

REPLACEMENT AIR NOZZLES

2

(*) Sold Separately

27

REPLACEMENT TIPS

(*) Sold Separately

26

TABLE OF CONTENTS

Product Description ……………………………………

Product Illustration ……………………………………

Package Inclusion ……………………………………

Specifications ……………………………………

Functions and Features ……………………………… 7

5

6

4

4

Safety Precautions …………………………………… 8

Assembly and Preparation ……………………………… 9

Control Panel Guide …………………………………… 10

Operating Guidelines ……………………………… 11 — 19

How to use the RESET button?

How to use the CAL (calibration) utility?

Initial Procedures

Hot Air Gun

Soldering Iron

Desoldering Gun

Auto-Stand-By Mode Timer (Hot Air Gun)

Auto-Sleep Mode (Soldering Iron and Desoldering Gun)

Care and Maintenance ……………………………. 20 — 21

Basic Troubleshooting Guide ………………………. 22 — 25

Miscellaneous Section ……………………………. 26 — 27

Replacement Tips

Air Nozzles

3

PRODUCT DESCRIPTION

The  Aoyue  I NT 2702  Lead­Free  Repairing  System  is  a  reworking  equipment  that  combines  the  functionality  of  Hot  Air  Gun,  Soldering 

Iron,  Smoke  Absorber,  and  Desoldering  Gun  in  one  sophisticated  package. 

One  of  the  notable  features  of  this  device  is  the  auto­cooling  process of the Hot Air Gun. This functionality protects the device (and its  components) from excessive heat by blowing air (at room temperature)  upon  reaching  any  of  the  following  two  conditions:  (1)  when  the  soldering gun remained idle on its  resting handle after a certain period  and  (2)  when  the  temperature  of  the  device  is  above  a  safe  threshold  upon  turning  off.  This  will  be  discussed  in  greater  detail  together  with  the complete features in the succeeding sections of this manual. 

Finally, the unique, innovative design with digital control panel and  display  provides  precision,  safety,  and  ease  of  use  to  match  all  reworking requirements.

PRODUCT ILLUSTRATION

BASIC TROUBLESHOOTING GUIDE

SOLUTION:  The  temperature  of  the  desoldering  gun  fell  below  the  minimum (< 200°C). Try to increase the temperature slightly until this  error message ceases. Please also note of temperature fluctuations. 

PROBLEM 9: DISPLAY AND OTHER DEVICE OPERATION ISSUES 

SOLUTION:  Try  to  press  the  RESET  button  on  the  device.  Note  that  resetting the device will also reset all previously defined configurations. 

OTHER PROBLEMS NOT MENTIONED: 

Contact the vendor.

4  25 

BASIC TROUBLESHOOTING GUIDE 

Case 4:  The Vacuum cap is connected but airflow level is still low. 

SOLUTION: 

Check the filter pad inside the vacuum cap for dirt that can block the air  passage. Clean or replace if necessary. 

ADDITIONAL SOLUTION: Check  for  any  tangles  in  the  tube  of  the  hot air gun that can cause the air blockage. 

PROBLEM  8:  SOLDERING  /  DESOLDERING  TEMPERATURE 

DISPLAY PANEL SHOWS UNRECOGNIZABLE CHARACTERS 

Case 1:  The  system  produces  five  (5)  high  beep  sounds  then  shows  something  like  “uuu”  from  the  soldering  /  desoldering  temperature  display panel. 

SOLUTION 1:  Check  if  the  soldering  iron  or  the  desoldering  gun  connection assembly is connected to the 6­pin receptacle of the control  panel. Double check the pin connections if possible. 

SOLUTION 2:  Make sure the soldering iron tip is  properly inserted  and  secured  inside  the  handle.  Lose  contacts  between  the  tip  and  handle can cause this error message. 

Case 2:  The  system  produces  five  (5)  high  beep  sounds  then  shows  something  like  “ttt”  from  the  soldering  /  desoldering  temperature  display panel. 

24

PACCKAGE INCLUSIONS

2702 Main Station 

939 Vacuum Suction Pen 

Hot Air Gun and 

Hot Air Gun Holder 

G001 IC Popper 

LF­2B Tip with 

Heater Cartridge 

30150J 

Heat Resistant Pad 

Soldering Iron with 

Smoke Absorber 

20125 Filter 

Spring 

Desoldering tips 

Desoldering Gun  and Holder 

201242 Nozzle  cleaning pin 

3017J Filter 

Pads(6 pcs.) 

2630B Soldering Iron Holder  with Solder Wire Stand 

Filter Vacuum Cap

Suction Vacuum Cap 

Power Cord 

Air Nozzles 

(1124, 1130, 1197, 1313, 1919,1010) 

MAIN STATION 

Power Input : 

Station Dimensions: 

Weight: 

SOLDERING IRON 

Power Consumption: 

Temperature Range: 

Heating Element: 

Output Voltage: 

HOT AIR GUN 

Power Consumption: 

Temperature Range: 

Heating Element 

Pump/Motor Type: 

Air Capacity: 

DESOLDERING GUN 

Temperature Range: 

Heating Element: 

Output Voltage: 

Suction Flow: 

Vacuum Generator: 

Vacuum Pressure: 

SPECIFICATION 

available in 110V / 220V 

188(w) x 126(h) x 250(d) mm 

5.6Kg 

70W 

250°C ­ 480°C 

Ceramic Heater 

24V 

500W 

100°C ­ 480°C 

Metal Heating Core 

Diaphragm Pump 

23 l /min (max) 

380°C ­ 480°C 

Ceramic Heater 

36V 

15 l /min (max) 

Vacuum Pump 

600mm Hg 

6

BASIC TROUBLESHOOTING GUIDE 

PROBLEM 6: THE UNIT IS VERY NOISY 

SOLUTION: 

Make  sure  the  screw  at  the  center  of  the  base  of  the  main  unit  has  been removed. This holds the pump in place during transportation and  needs to be removed before using the equipment. 

PROBLEM 7: AIR PRESSURE LEVEL IS SIGNIFICANTLY LOW NO 

MATTER HOW HIGH THE AIRFLOW LEVEL IS CALIBRATED 

Case  1:  Check  the  mains  voltage  (AC  power  source).  If  the  voltage  level  falls  significantly  low,  about  15­20%  lower  than  the  standard,  there will also be a noticeable drop in the air pressure level. 

SOLUTION: 

Please refer to your local power service provider. 

Case  2:  The  microcontroller  might  have  detected  the  operating  frequency  incorrectly.  The  user  will  notice  that  airflow  level  is  weaker  with reference to the airflow gauge compared with the displayed value. 

SOLUTION: 

Try to press the RESET button on the panel to let the device re­detect  the proper operating frequency. Note that resetting the device will also  reset all previously defined configurations to system default parameters. 

Case 3:  The Suction Vacuum cap is connected to the Smoke Absorber 

Terminal or Vacuum cap instead of the Filter Vacuum cap. 

SOLUTION: 

Change  the  cap  to  the  Filter  Vacuum  cap  or  the  cap  with  the  wider  mouthpiece.  This  allows  more  air  to  pass  through  the  system.  Make  sure as well that the vacuum tube of the soldering iron or desoldering  gun is not connected.

23

BASIC TROUBLESHOOTING GUIDE 

PROBLEM 1: THE UNIT HAS NO POWER 

1.  Check if the unit is switched ON. 

2.  Check the fuse. Replace with the same type if fuse is blown. 

3.  Check the power cord and make sure there are no disconnections. 

4.  Verify that the unit is properly connected to the power source. 

PROBLEM 2: TEMPERATURE DISPLAY IS ALWAYS ABOVE 500  o 

Description:  Constant  display  of  above  500  o  C  temperature  from  the  panel then displays a blinking “OFF” on  the panel after a few minutes. 

SOLUTION: 

The thermal sensor may be broken and needs to be replaced. 

PROBLEM 3: ACTUAL AIR TEMPERATURE IS NOT INCREASING 

Description:  Actual  temperature  reading  is  not  increasing  or  decreasing based on desired level. The panel will then display a blinking 

“OFF” on panel. 

SOLUTION: 

The heating element may be broken and needs to be replaced. 

PROBLEM  4:  BANNER  OR  PRODUCT  NAME  IS  ALWAYS 

SCROLLING ­ THE UNIT IS NOT USABLE 

Description:  The product name is always just scrolling from the digital  panel, rendering the device unusable. 

SOLUTION: 

Try  to  press  RESET  from  the  control  panel.  Note  that  resetting  the  device will also reset all previously defined configurations. 

PROBLEM 5: THE UNIT IS VIBRATING TOO MUCH 

SOLUTION:  Check  if  the  4  screws  that  hold  the  pump  in  place  are  properly and tightly connected. Unplug the system from the main power  source before opening the case to check inside the station. 

22

FUNCTION and FEATURES

● 

● 

● 

● 

● 

● 

● 

● 

● 

● 

● 

Microprocessor­controlled ESD safe equipment. 

3­in­1 repairing system combining Hot Air Gun, Soldering Iron, and 

Desoldering Gun in one sophisticated package. 

Digital  control  and  display  of  hot  air  temperature,  soldering  iron  temperature,  desoldering  gun  temperature  and  air  pressure  with  touch type panel controls for precision and ease of use. 

The  desoldering  gun  is  equipped  with  air  cylinder  type  vacuum  pump  for  stronger  suction  and  zero­crossing  circuit  that  prevents  electrical surges. 

Integrated  smoke  absorber  functionality  with  filter  pad  to  efficiently absorb and filter harmful fumes. 

Uniquely  designed  compound  tip  that  integrates  the  ceramic  heating element and sensor in just one component. Replacing tips  is as easy as slipping it in/out of the compatible 24V soldering iron. 

User configurable 1 to 20 minute idle­to­auto­stand­by mode (with 

5  minutes  as  default)  for  additional  device  protection  and  power  saving. 

Built­in  auto­cooling  process  that  protects  the  system  and  its  components from excessive heat, prolonging usage life. 

Built­in auto­sleep mode for soldering iron and desoldering gun. 

Compatibility with air nozzles of various types. 

Compatibility with different kind of soldering tips.

7

SAFETY PRECAUTIONS 

CAUTION:  Improper usage can cause serious injury to personnel  and/or damage to equipment. For your own safety, please observe the 

● 

● 

● 

● 

● 

● 

● 

● 

● 

● 

● 

Check each component after opening the package to make sure everything  is  in  good  condition.  If  there  are  any  suspected  damage,  do  not  use  the  item and report the issue to your vendor. 

Turn OFF the main power switch and unplug the device when moving the  device from one location to another. 

Do  not  strike  or  subject  the  main  unit  to  physical  shock.  Use  carefully  to  avoid injury and damage to any part. 

Handle with care. 

­ Never drop or sharply jolt the unit. 

­ Contains delicate parts that may break if the unit is dropped. 

Make sure the equipment is always grounded. Always connect power to a  grounded receptacle. 

Temperature may reach as high as 480°C when switched ON. 

­ Do not use the device near flammable gases, paper and other flammable  materials. 

­ Do not touch heated parts, which can cause severe burns. 

­ Do not touch metallic parts near the tip. 

Disconnect the plug from the power source if the unit will not be used for a  long period. 

­ Turn off power during breaks, if possible. 

Use only genuine replacement parts. 

­ Turn off power and let the unit cool before replacing parts. 

The  unit  may  produce  a  small  amount of  smoke  and  unusual odor  during  initial usage. This is normal and should not yield any negative result when  reworking. 

Soldering process produces smoke — use on well ventilated place. 

Do not alter the unit, specifically the internal circuitry, in any manner. 

8

CARE and MAINTENANCE

Checking the soldering iron connection cord for damages

1.  Remove the soldering tip and the nipple. 

2.  Push the socket out from the handle assembly. 

3.  Measure the resistance values between the connector and the lead  wires at the socket as follows: 

Pin 1  ­ Red ( + ) 

Pin 3  ­ Blue (ground) 

Pin 5  ­ Black ( ­ ) 

If any value exceeds 0Ω (shorted)  or  ∞  (infinitely  large  —  open),  replace the handle assembly.

Replacing the heating element of the Hot Air Gun

The heating element is found in the middle part of the hot air gun. 

The normal life of a heating element is  1 year under normal operating  conditions. 

Steps: 

1.  Loosen the 3 screws that secure the handle. 

2.  Slide off the plastic tube. 

3.  Disconnect the ground wire sleeve. 

4.  Inside  the  pipe,  the  quartz  glass  and  heat  insulation  are  installed. Loosen the cable and take out the heating element.

 

5.  Insert  new  heating  element  and  reconnect  the  terminal.  Be  careful not to rub Heating Element wire. 

6.  Reconnect the ground wire after replacing the element. 

7.  Assemble the handle again.

21

CARE and MAINTENANCE

Blower/Vacuum Air Terminal Filters

Filters should be cleaned and replaced regularly to avoid dirt which can  clog  the  air  passage.  More  importantly,  this  will  also  effectively  clean  the toxic fumes produced during soldering process.

Soldering Iron Tip

Always  keep  the  solder­plated  section  of  the  tip/nozzle  coated  with  a  small amount of solder. Oxide coating on the tip of the nozzle reduces  its heat conductivity. Coating the tip with a small amount of fresh solder  ensures maximum heat conductivity is obtained.

Replacing the Soldering Iron tip

1.  Always  turn  OFF  main  power  switch  when  removing  or  inserting  a  tip. 

2.  If the tip is hot, use the heat resistant pad to pull it out. 

3.  Insert the new tip fully into the handle. If the tip is not fully inserted 

(or  if  the  tip  is  damaged),  the  device  will  produce  five  high  beep  sounds  then  show  the  following  from  the  SOLDER/DESOLDER 

TEMPERATURE display panel (“13”). 

Spare Parts Guide

Part No. 

10094 

30106S 

S009 

20962 

B012 

C005 

3072D 

B1003 

Description 

Hot air gun heating element 

Plastic handle of hot air gun 

Hot air gun complete handle 

Hot air gun metal pipe 

Soldering Iron complete handle 

Desoldering gun heating element 

Plastic handle of desoldering gun 

Desoldering gun complete handle

20

ASSEMBLY and PREPARATIONS 

A. Main Station

As  soon  as  the  equipment  has  been  removed  from  the  package,  REMOVE 

THE  SCREW  located  at  the  center  of  the  bottom  of  the  main  unit.  This  screw holds the pump in place during transportation.

WARNING:  Failure  to  remove  the  screw  before  using  the  equipment can cause damage to the system.

B. Soldering Iron

1.  Install the solder wire to the soldering iron holder as in Figure 1. 

Figure 1. Soldering iron stand with solder wire holder

2 .  Connect  the  soldering  iron  cord  assembly  to  the  6­pin  output  terminal  found at the lower middle portion of the main unit. 

3.  Place the soldering iron to the soldering iron stand as shown above.

C. Smoke Absorber

1.  Attach the smoke absorbing tube to the suction vacuum cap. Make sure  the cord connections are free from tangles.

D. Hot Air Gun

The  Hot  Air  Gun  holder  was  installed  on  the  station  upside  down  for  packaging purpose. To set up the Hot Air Gun holder: 

1.  Loosen the two screws that secure the holder to the station. 

2.  Turn the holder right side up. 

3.  Re­fasten the two screws. 

4.  Place the hot air gun onto the holder in preparation for usage.

E. Desoldering Gun

1.  Connect the cord assembly of the desoldering gun to the 6­pin terminal . 

2.  Connect the vacuum tube to the suction vacuum cap. 

3.  Place the desoldering gun onto the holder in preparation for usage. 

9

CONTROL PANEL GUIDE 

LEGEND: 

1 — Airflow Gauge 

2 — Hot Air Gun Temperature Adjustment Buttons 

3 — Hot Air Gun Airflow Adjustment Buttons 

4 — Soldering Iron / Desoldering Gun Temp Control Buttons 

5 — Calibration Utility Terminal 

6 — Hot Air Gun Output Terminal 

7 — Smoke Absorber Terminal or Vacuum Cap 

8 — Soldering Iron / Desoldering Gun 6­Pin Receptacle 

9 — Main Power Switch 

10 — Blower / Vacuum Activation Switch 

11 — Hot Air Gun Temperature Display 

12 — Hot Air Gun Air Pressure Display 

13 — Soldering Iron / Desoldering Gun Temperature Display 

14 — Hot Air Gun Activation Switch 

15 — Reset Button 

16 — Smoke Absorber Switch 

17 — Soldering Iron / Desoldering Gun Activation Switch 

10

OPERATING GUIDELINES

ADDITIONAL NOTES on AUTO-SLEEP MODE

1.  The  default  time  before  the  soldering  iron  or  the  desoldering  gun  goes  to  sleep  mode  is  30  minutes.  This  is  also  fixed  and  non­  configurable. 

2.  Once  the  system  determines  that  the  time  has  elapsed,  it  will  gradually  decrease  the  temperature  of  the  soldering  iron  or  the  desoldering gun then show the following from the display panel of  the SOLDER/DESOLDER TEMPERATURE.

3.  To  deactivate  the  auto­sleep  mode,  deactivate  the  SOLDER  IRON  then  activate  it  again,  this  time,  without  holding  the  Soldering  / 

Desoldering  Temperature  Adjustment  buttons.  Note  that  pressing  this  will  also  remove  the  previous  temperature  value.  Re­  adjustment may be necessary.

ADDITIONAL NOTES:

SOLDERING IRON and DESOLDERING GUN

1.  Because  of  the  difference  in  the  heating  element  and  size  of  the  soldering iron tip and desoldering gun,  the soldering iron will heat  up  faster  than  the  desoldering  gun.  This  is  normal  and  does  not  have any impact on the system’s performance. 

2.  There will be a slight drop in temperature display once the trigger  of the desoldering gun is used. This is due to rapid intake of air in  which  temperature  is  significantly  cooler  than  the  desoldering  gun  tip.  When  the  system  detects  this,  it  will  automatically  adjust  the  temperature to compensate for the temperature difference. 

19

CONTROL PANEL GUIDE 

F. Activating Soldering Iron & Desoldering Gun Auto-Sleep Mode

Aside from the auto stand­by mode feature of the hot air gun, the  device  has  a  separate  mechanism  to  put  the  soldering  iron  or  desoldering gun into SLEEP mode after a certain period. By default, this  is  deactivated  and  the  user  must  do  any  of  the  following  two  sets  of  procedures (whichever is applicable) in order to activate this feature. 

CONDITION 1:  Device is initially switched OFF (main power switch OFF) 

1.  Make sure all function switches are deactivated. 

2.  Turn ON the main power switch. 

3.  Hold  both  UP  and  DOWN  buttons  of  the  SOLDER/DESOLDER 

TEMPERATURE Adjustment buttons. 

4.  Activate the SOLDER IRON switch while still holding both the UP  and DOWN buttons from the previous step. 

5.  Make  sure  the  following  was  momentarily  shown  from  the  soldering iron / desoldering gun temperature display panel  (“13”  from the control panel). 

6.  Release the two buttons to put the  device into operation. 

CONDITION 2:  Device is already switched ON 

1.  Hold  both  UP  and  DOWN  buttons  of  the  SOLDER/DESOLDER 

TEMPERATURE Adjustment buttons. 

2.  Press  the RESET  button  once  while still  holding  the  two  buttons  from the previous step. 

3.  Make sure the same display above was momentarily shown from  the soldering iron / desoldering gun temperature display panel. 

4.  Release the two buttons to put the device back into operation. 

NOTE: The auto sleep feature is automatically deactivated when  the device is switched OFF or when the RESET button is 

pressed without doing the procedures specified above.

18

OPERATING GUIDELINES

IMPORTANT REMINDERS: 

1.  Make  sure  the  equipment  is  placed  on  a  flat  stable  surface  and  all  the  heat­generating  components  placed  on  their  respective holders or stands. 

2.  Ensure all function switches are OFF prior to reworking. 

3.  Ensure all terminal connections are properly secured. 

IMPORTANT:  Please  refer  to  the  CONTROL  PANEL  GUIDE  page for buttons and display panel directory. 

How to use the RESET button? 

The  RESET  button  (“15”  from  the  control  panel)  is  used  to  reconfigure  temperature  and  airflow level  settings. In  very  rare  cases,  this may also solve some minor display or operation issues (see BASIC 

TROUBLESHOOTING  GUIDE  for  further  details).  When  pressed,  the  system  will  temporarily  switch  to  stand­by  mode  then  start  the  device  using  factory  default  operating  parameters  (provided  the  respective  function switch is activated): 

Hot Air Gun Temperature:  100  o  C 

Hot Air Gun Airflow Level: 

Soldering Iron Temperature: 

51 

350  o  C 

NOTE: Pressing the RESET button removes user‐configured sys‐ 

tem values. Reconfiguration may then be necessary.

How to use the CAL (calibration) utility? 

In special cases, it may be necessary to synchronize the amount of  heat  delivered  by  the  soldering  iron  with  an  external  temperature  sensing  device.  This  can  be  achieved  by  slowly  tuning  the  CAL  or  calibration utility (“5” from the control panel) using a small screw driver  until  the  approximate  operating  temperature  on  both  devices  are  synchronized. 

11 

OPERATING GUIDELINES

A. INITIAL PROCEDURES

1.  Plug  the  device  to  the  main  power  source  using  the  power  cord  provided in the package. 

2.  With  all  function  switches  deactivated  and  all  terminal  connections  properly  secured,  switch  ON  the  device  by  activating  the  main  power switch (“9” from the control panel).

IMPORTANT: Initial control panel setting includes the BLOWER/VACUUM 

ACTIVATION switch (“10” from control panel) set to “Blow 

3.  The  display  panels,  11  and  12  will  temporarily  show  the  product  name  in  a  scrolling  manner  and  then  display  “OFF”  on  both  rows  once  the  scroll  is  finished  (see  below  illustration).  The  system  will  remain at this state until the user activates a function. 

B. HOT AIR GUN

1.  Follow the initial procedures above, “A. INITIAL PROCEDURES”. 

2.  Activate “Hot Air Gun” switch (“14” from the control panel). 

3.  The  system  will immediately  start  to  blow  air  at  an  airflow  rate  of 

51 while rapidly and safely increasing the air temperature to 100°C 

(default  system  operating  parameters).  These  values  will  be  reflected  from  the  Hot  Air  Gun  Air  Temperature  and    Air  Pressure  display  panels,  “11”  and  “12”  from  the  control  panel,  respectively. 

The metal ball inside the air gauge (“1” from the control panel) will  also  settle  somewhere  in  the  middle  of  the  visible  area  indicating  that  the  system  is  blowing  air  at  an  average  or  normal  rate.  (See  illustrations on the next page.) 

12

OPERATING GUIDELINES 

E. Auto-Stand-By Mode (Hot Air Gun)

The device has a built­in timer such that if the Hot Air Gun sits on  its  handle  and  remain  idle  for  a  certain  period,  the  device  will  switch  indefinitely  to  stand­by  mode  (provided  the  power  delivered  to  the  system  remain  uninterrupted).  Once  the  countdown  time  has  elapsed,  the  system  will  blow  air  (at  room  temperature)  at  a  maximum  rate  in  order to bring down the temperature. During this time, the prefix of the  display  for  Hot  Air  Gun  air  temperature  will  change  from  “A”  to  “d”. 

Once the temperature drops to approximately 90°C, the Hot Air Gun will  automatically  stop  and  show  an  all­dash  display  indicating  that  the  system is now on stand­by. 

The  device  will  automatically  switch  back  into  operation  with  the  last  user­defined  parameters,  i.e.,  hot  air  gun  temperature,  airflow  level, etc., when the Hot Air Gun is lifted again from the handle. 

By  default,  the  system  has  a  5­minute  countdown  time.  This  can  be altered by the following procedures. 

1. Upon system start­up, while the product name is scrolling from the  display  panel,  hold  the  UP  button  of  the  AIR  PRESSURE 

Adjustment buttons and wait until “L05” is displayed. 

2. Adjust the time using the UP and DOWN buttons of the HOT AIR 

GUN TEMPERATURE Adjustment buttons. 

3. Confirm  the  change  by  pressing  the  DOWN  button  of  the  AIR 

PRESSURE Adjustment buttons. 

4. The  system  will  automatically  switch  back  into  operation  and  use  the defined countdown parameter.

ADDITIONAL NOTES: 

1.  The alternative to first step above is to press the RESET  button then hold the UP  button of the AIR PRESSURE Adjustment buttons until “L05” is displayed. Note  that pressing RESET removes user­defined configurations. 

2.  The countdown timer is configurable between 1 and 20 minutes.

17

OPERATING GUIDELINES

D. DESOLDERING GUN

1.  Connect  the  Desoldering  Gun  connection  assembly  to  the  6­pin  receptacle  at  the  front  of  the  control  panel  (“8”  from  CONTROL 

PANEL GUIDE). 

2.  Follow the initial procedures (“A. INITIAL PROCEDURES”). 

3.  Connect  the  vacuum  tube  to  the  Smoke  Absorber  Terminal  or 

Vacuum Cap (“7” from the control panel). 

4.  IMPORTANT:  Set the BLOWER or VACUUM ACTIVATION switch to 

Vacuum Air”. 

5.  Activate  the  “SOLDER  IRON”  Activation  switch  (“17”  from  control  panel).  This  will  automatically  start  to  increase  the  temperature  of  the desoldering gun to 350°C (default). 

NOTE:  The  system  will  produce  a  high  beep  sound  when  the  default  temperature (or when the desired temperature) is reached. 

6.  Adjust  the  desoldering  gun  temp.  using  the  SOLDER/DESOLDER 

TEMPERATURE ADJUSTMENT buttons (“4” from the control panel). 

7.  You  may  start  using  the  desoldering  gun  when  the  desired  temperature  is  reached.  Use  the  trigger  of  the  desoldering  gun  to  pick up unnecessary solder leads. 

8.  When the task is finished, deactivate the SOLDER IRON switch. 

9.  Set the BLOWER/VACUUM ACTIVATION switch back to “Blow Air”. 

10. Detach  the  desoldering  gun  connection  assembly  from  the  6­pin  receptacle at the control panel as well as the vacuum tube from the  vacuum cap (if necessary). 

11. Allow  sufficient  time  for  the  desoldering  gun  to  cool  down  before  keeping in a safe storage. (Optional but recommended) 

NOTE:  The  soldering  iron  and  desoldering  gun  operating 

temperature is configurable between 200°C and 480°C.

IMPORTANT:  Make  sure  the  SMOKE  ABSORBER  switch  is  deactivated  while  using  the  desoldering  gun.  Otherwise, 

the desoldering gun will keep on sucking air indefinitely.

16 

OPERATING GUIDELINES

Default System Parameters (Hot Air Gun) 

4.  Adjust  the  air  flow  level  using  the  AIR  PRESSURE  ADJUSTMENT 

BUTTONS (“3” from the control panel). The prefix of the display for 

Air Pressure will change from “F” to “E” while air flow level is being  adjusted. It will return to “F” as soon as the desired level is reached. 

In the case below, the final airflow level is “F89”. 

5.  Adjust  the  hot  air  gun  air  temperature  using  the  HOT  AIR  GUN 

TEMPERATURE  ADJUSTMENT  BUTTONS  (“2”  from  the  control  panel).  The  prefix  of  the  display  for  Hot  Air  Gun  Temperature  will  change  from  “A”  to  “b”  indicating  that  air  temperature  is  being  adjusted.  It  will  return  to  “A”  while  the  temperature  is  gradually  increasing or decreasing until the desired temperature is reached. In  the example below, final air gun temperature is “A380”.

IMPORTANT:  When  adjusting  the  air  temperature, it  is  strongly  advised  to  initially  increase  the  airflow  level  in  order  to  manage  the  system  temperature.  This  is  to  protect  the  heating  element  inside  the  handle  from  excessive  heat  and  avoid  the  possibility  of  subjecting adjacent components to thermal shock. 

13

OPERATING GUIDELINES

6.  Reworking  task  can  be  started  as  soon  as  the  desired  hot  air  temperature  and  airflow  level  are  reached,  as  also  indicated  from  display panels “11” and “12”, respectively. 

7.  When  reworking  is  complete,  return  the  Hot  Air  Gun  to  its  holder  and DO NOT immediately turn off the main power switch. 

8.  Deactivate the Hot Air Gun Activation button first in order to activate  the auto­cooling process. The system will start to blow air (at room  temperature) at a fast rate to reduce heat from the hot air gun and  bring  down  the  temperature  to  a  reasonable  safe  level  of  90°C

During  this  time,  the  prefix  of  the  display  for  hot  air  gun  temperature  will  also  change  from  “A”  to  “E”  while  temperature  is  gradually decreasing. Likewise, the air pressure level is at its highest  reading  as  indicated  from  the  display  panel.  Once  the  temperature  drops to approximately 90°C  the system will halt and display “OFF”  on  the  panel.  It  is  now  safe  to  switch  off  the  main  power  switch. 

See illustration below. 

9.  Turn OFF the main power switch. 

10. Unplug the device from the main power source. 

NOTES: 

1.  Hot Air Gun Temperature is adjustable between 100°  and 480°C with an increment of 10° on each step. 

2.  Hot Air Gun Airflow Rate is adjustable between 6 and 

99 with an increment of 3 on each step. 

14

OPERATING GUIDELINES

C. SOLDERING IRON

1.  Connect  the  Soldering  Iron  connection  assembly  to  the  6­pin  receptacle  located  at  the  front  of  the  control  panel  (“8”  from  the 

CONTROL PANEL GUIDE). 

IMPORTANT NOTE:  Steps 3, 4, 7, 9, and 11 are optional when using only the  soldering iron. If the smoke absorber function will be  used, these procedures are required.

3.  Connect  the  vacuum  tube  to  the  Smoke  Absorber  Terminal  or 

Vacuum Cap (“7” from the control panel). 

4.  IMPORTANT:  Set the BLOWER or VACUUM ACTIVATION switch to 

Vacuum Air”. 

5.  Activate  the  “SOLDER  IRON”  Activation  switch  (“17”  from  control  panel).  This  will  automatically  start  to  increase  the  temperature  of  the soldering iron to 350°C (default). 

NOTE:  A high beep sound will be heard when the default temperature 

(or when the desired temperature) is reached. 

6.  Adjust the soldering iron temperature using the SOLDER/DESOLDER 

TEMPERATURE ADJUSTMENT buttons (“4” from the control panel). 

7.  Activate  the  “SMOKE  ABSORBER”  Activation  switch  (“16”  from  the  control panel). 

8.  Start  using  the  soldering  iron  as  soon  as  desired  temperature  is  reached. 

9.  When the task is finished, deactivate the SMOKE ABSORBER switch. 

10. Deactivate the SOLDER IRON activation switch. 

11. Set the BLOWER/VACUUM ACTIVATION switch back to “Blow Air”. 

12. Detach  the  soldering  iron  connection  assembly  from  the  6­pin  receptacle at the control panel as well as the vacuum tube from the  vacuum cap (if necessary). 

13. Allow  sufficient  time  for  the  soldering  iron  to  cool  down  before  keeping in a safe storage. (Optional but recommended)

15

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement