Sharp | AF-100DX | AF-R140DX | AF-S120DX | AF-R120DX | User manual | AF-S100DX/120DX | AF-R100DX/R120DX/140DX Operation Manual


Add to my manuals
20 Pages

advertisement

Sharp | AF-100DX | AF-R140DX | AF-S120DX | AF-R120DX | User manual | AF-S100DX/120DX | AF-R100DX/R120DX/140DX Operation Manual | Manualzz

AF-S100DX

AF-S120DX

AF-R100DX

AF-R120DX

AF-R140DX

ROOM AIR CONDITIONER

INSTALLATION AND OPERATION

MANUAL

CONTENTS

PAGE

FOR YOUR PROTECTION ....................

2

CONSUMER LIMITED WARRANTY .....

3

INSTALLATION INSTRUCTIONS

• CHECK WINDOW AREA ........................ 4

• LOCATlON .............................................. 4

• ITEMS PACKED WITH THlS UNIT ......... 5

• SUGGESTED TOOLS ............................ 5

• INSTALLATION ....................................... 5

PRECAUTIONS

CAUTION FOR USE ............................ 8

• GROUNDING INSTRUCTIONS ........... 8

• NOTES ON OPERATION .................... 9

• ENERGY EFFICIENCY TIPS ............... 9

HOW TO OPERATE

This INSTALLATION AND OPERATION

MANUAL explains the proper use of your new

Sharp Air Conditioner. Read these instructions carefully before installing or operating your air conditioner. The INSTALLATION AND OP-

ERATION MANUAL should be kept in a safe place for handy reference.

• PARTS NAMES ................................... 10

COOLING OPERATION ...................... 11

• TO CHANGE TEMPERATURE SETTING .......... 11

• TO CHANGE FAN SPEED AND

OPERATION MODE ....... 12

• ENERGY SAVER ................................. 13

• TO CHANGE AIR FLOW DIRECTION ....... 13

• EXHAUST ............................................ 13

• ON TIMER OPERATION ..................... 14

• OFF TIMER OPERATION .................... 15

• USING THE REMOTE CONTROL ....... 16

CLEANING AND MAINTENANCE ........

18

BEFORE CALLING FOR SERVlCE ......

19

As an ENERGY STAR Partner, Sharp Electronics has determined that this product (AF-S100DX, AF-

S120DX) meets the ENERGY STAR guidelines for energy efficient air conditioners. To meet these guidelines, air conditioners must be at least 10% more efficient than the minimum Federal standard.

2

FOR YOUR PROTECTION

To aid in answering questions if you call for service or for reporting loss or theft, please record below the model and serial number located on the right side of the unit.

MODEL NUMBER

SERIAL NUMBER

DATE OF PURCHASE

Dealer Name

Address

City

State

Zip

Telephone

TO PHONE: Dial 1-800-BE-SHARP (237-4277) for:

SERVICE (for your nearest Sharp Authorized Servicer)

PARTS (for your Authorized Parts Distributor)

ACCESSORIES

ADDITIONAL CUSTOMER INFORMATION

TO WRITE: For service problems, warranty information, missing items and other assistance:

Sharp Electronics Corporation

Customer Assistance Center

1300 Naperville Drive

Romeoville, IL 60446-1091

Please provide the following information when you write or call: model number, serial number, date of purchase, your complete mailing address (including zip code), your daytime telephone number (including area code) and description of the problem.

CONSUMER LIMITED WARRANTY

CONSUMER LIMITED WARRANTY

SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the "Product"), when shipped in its original container, will be free from defective workmanship and materials, and agrees that it will, at its option, either repair the defect or replace the defective Product or part thereof with a new or remanufactured equivalent at no charge to the purchaser for parts or labor for the period(s) set forth below.

This warranty does not apply to any appearance items of the Product nor to the additional excluded item(s) set forth below nor to any Product the exterior of which has been damaged or defaced, which has been subjected to improper voltage or other misuse, abnormal service or handling, or which has been altered or modified in design or construction.

In order to enforce the rights under this limited warranty, the purchaser should follow the steps set forth below and provide proof of purchase to the servicer.

The limited warranty described herein is in addition to whatever implied warranties may be granted to purchasers by law. ALL

IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR USE ARE LIMITED

TO THE PERIOD(S) FROM THE DATE OF PURCHASE SET FORTH BELOW. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

Neither the sales personnel of the seller nor any other person is authorized to make any warranties other than those described herein, or to extend the duration of any warranties beyond the time period described herein on behalf of Sharp.

The warranties described herein shall be the sole and exclusive warranties granted by Sharp and shall be the sole and exclusive remedy available to the purchaser. Correction of defects, in the manner and for the period of time described herein, shall constitute complete fulfillment of all liabilities and responsibilities of Sharp to the purchaser with respect to the Product, and shall constitute full satisfaction of all claims, whether based on contract, negligence, strict liability or otherwise. In no event shall Sharp be liable, or in any way responsible, for any damages or defects in the Product which were caused by repairs or attempted repairs performed by anyone other than an authorized servicer. Nor shall Sharp be liable or in any way responsible for any incidental or consequential economic or property damage. Some states do not allow the exclusion of incidental or consequential damages, so the above exclusion may not apply to you.

THIS WARRANTY GIVES YOU SPECIFlC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM

STATE TO STATE.

Your Product Model Number & Description:

Warranty Period for this Product:

Additional Item(s) Excluded From

Warranty Coverage (If any):

Where to Obtain Service:

What to Do to Obtain Service:

AF-S100DX, AF-S120DX, AF-R100DX, AF-R120DX, or AF-R140DX

Room Air Conditioner. Be sure to have this information available when you need service for your Product.

One (1) year parts and labor from date of purchase. The warranty period continues for a total of five (5) years from date of purchase for the Sealed Cooling System parts; labor and service are not provided free of charge for this additional period.

Appearance items of the Product, knobs, filter, or accessories, mounting kit, seals, or any printed materials.

From a Sharp Authorized Servicer located in the United States. To find the location of the nearest Sharp Authorized Servicer, call Sharp Toll Free at

1-800-BE-SHARP.

Contact your Sharp Authorized Servicer to obtain in-home service for this

Product. The Servicer will come to your home, and if it is necessary to remove the Product, the Servicer will reinstall it. Be sure to have Proof of

Purchase available.

TO OBTAIN SUPPLY, ACCESSORY OR PRODUCT INFORMATION, GO TO OUR WEBSITE AT www.sharpusa.com

OR CALL 1-800-BE-SHARP.

SHARP ELECTRONICS CORPORATION

Sharp Plaza, Mahwah, New Jersey 07430-2135

3

INSTALLATION INSTRUCTIONS

Before beginning installation, read these instructions carefully.

Use the enclosed MOUNTING KIT for proper installation.

CHECK WINDOW AREA

The mounting kit is designed for wooden sill double or single hung sash-type windows.

Minimum opening

(Without mounting kit)

Mounting kit fully closed

Mounting kit fully opened

4

Window opening from stool to lower sash bottom must

Lower sash bottom

Stool

LOCATION

The air conditioner should be installed on a firm foundation to minimize noise and vibration.

For safe installation, repairs, replacement and secure positioning, make sure foundation is solid and level.

The room air conditioner must be installed in an area within reach of a properly rated grounded outlet.

Use of extension cords of any kind is not recommended.

Never place any obstacles around air inlet.

INSTALLATION INSTRUCTIONS

ITEMS PACKED WITH THIS UNIT

5

6

7

8

9

10

No.

1

2

3

4

Accessories

Right closure assembly

Left closure assembly

Window sash foam seal

Window sash foam seal

(adhesive type)

Bottom gasket

Screws(L=1", 25.4mm)

Remote control

Battery

Remote control hook

1

1

8

2

1

6

1

Q'ty

1

1

1

6

4

8

2

3

8

9

7

1

5

6

2

10

SUGGESTED TOOLS

1. Screw driver (medium size Phillips)

2. Tape measure or ruler

3. Knife or scissors

INSTALLATION

These models can also be installed through the wall with the optional through the wall mounting kit, model AZ-80WK. To order this kit either contact your dealer or call 1-800-BE-SHARP.

The wall opening dimensions for through the wall installation are:

Complete instructions are included with the wall mounting kit.

WARNING

: Make sure the unit is turned off and unplugged before working.

1

(1) Cut the window sash foam seal (adhesive type)

to the proper length and attach it to the

underside of the window sash.

window sash foam seal

(adhesive type)

(2) Attach the bottom gasket to the outer side of the

window sill.

bottom gasket

5

INSTALLATION INSTRUCTIONS

2

(1)

Unscrew the 2 screws at the corners of the front panel. Keep them as they will be used later.

(2)

Remove the front panel by pulling the front panel at the lower corners towards you about an inch.

Next lift it up and pull it towards you.

Front panel

CAUTION:

Take care not to damage the exhaust lever when removing the front panel.

3

(1)

Unscrew the 6 stopper screws of the cabinet. Keep the 4 screws from the top and front , as they will be used later.

(2)

Slide the chassis out from the cabinet by pulling on the hand hold located at the bottom center of the chassis.

CAUTION:

Do not remove any material (ex.

styrofoam, etc.) from inside the unit.

4

Insert the right closure assembly and the left closure assembly into the top angle and the bottom channels.

Secure the right and left closure to the cabinet with 6 of the provided screws.

13

(L= / ", 10 mm)

Closure assembly

Front panel

6

5

Open the window sash and place the cabinet on the sill.

Close the window sash securely behind the top angle.

If there is space between the bottom channel and the sill, fill the gap with a thin board or other hard filler.

WARNING

At this step, make sure the cabinet is inclined approximately 1 cm (3/8”) to the back.

If the cabinet is not properly inclined, the water collected in the bottom tray during operation will not drain properly and may flow into the room where the air conditioner is installed.

sill

Cabinet

Horizontal

Louver

Exhaust Lever incline backwards about 1cm (3/8")

INSTALLATION INSTRUCTIONS

6

7

Insert the closure assemblies on both sides into the rails of the jamb.

Jamb

(Left)

Closure assembly

(Left)

Indoor side

1/2 inch (13mm)

Sill

Stool

(1) Secure the cabinet to the window stool with 3 screws (L=1", 25.4 mm), working from the inside of the cabinet.

(2)

Secure the top angle and the closure assemblies to the window sash with 3 screws (L=1", 25.4 mm).

(3)

Secure the closure assemblies to the sill with 2 screws (L=1", 25.4 mm).

Closure assembly

(Left)

Top angle

8

(1)

Slide the chassis back into the cabinet.

(2) Replace the 4 screws removed in step 3 to the top and side of the cabinet .

9

(1) Replace the front panel. Slip the exhaust lever through the opening between the horizontal louver and the front panel then, hook the cabinet top.

CAUTION:

Take care not to damage the exhaust lever with the front panel.

(2)

Screw the front cabinet on at the bottom corners with 2 screws removed in step 2.

10

Cut the window sash foam seal to the proper length and seal the opening between the top of the inside window sash and the outside window sash.

Horizontal

Louver

Front

Panel

Exhaust Lever

Window sash foam seal

7

8

PRECAUTIONS

CAUTION FOR USE

IMPORTANT: Points to keep in mind when using your air conditioner.

Install the air conditioner by following the installation instructions given in the

previous section of this manua l.

Make sure the unit is the correct capacity for the area you want to cool.

Do not modify any part of this product.

Do not insert objects into any part of the unit.

Push the AC power plug securely into the receptacle and make sure it is not loose.

Use power circuit with a proper voltage rating.

Use a three-pronged grounded electrical outlet rated 125V,

60Hz, 15 amp or more, AC only as shown on right.

Use of an improper voltage rating power circuit can result in damage to the unit and possibly fire.

Two-Pole, 3-wire Grounding

Receptacle 15 Amps. 125V.

Always use a fuse with the proper amp rating

.

Do not, under any circumstances, use wire, pins or other objects in place of the proper fuse.

Use of extension cords of any kind is not recommende

d.

If you still elect to use an extension cord, it is absolutely necessary that it be a UL Listed 3-wire grounding type appliance extension cord rated 125 Volts, 15 amp or more.

Ventilate the room periodically during use, especially if using gas appliance

s.

GROUNDING INSTRUCTIONS

WARNING: Improper use of the grounding plug can result in the risk of electric shock.

This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current.

This appliance is equipped with a cord having a grounding wire with a grounding plug.

The plug must be plugged into an outlet that is properly installed and grounded.

WARNING: Do not under any circumstances cut or remove the round grounding prong from this plug.

If it is necessary to use an extension cord, use only a UL Listed 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the appliance.

The marked rating of the extension cord should be AC 125 Volt, 15 Amp or more.

Consult a qualified electrician or serviceman if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded.

If a grounding adapter is used, make sure the receptacle box is fully grounded.

3-Pronged receptacle

Grounding adapter

Grounded receptacle box

3-Pronged plug

Grounding prong

Grounded receptacle box

Screw

Tab for grounding screw

Grounding wire

PRECAUTIONS

NOTES ON OPERATION

• Allow 3 minutes for the compressor to restart cooling.

If you turn the air conditioner off and immediately restart it, allow three minutes for the compressor to restart cooling. There is an electronic device in the unit that keeps the compressor off three minutes for protection.

• If a power failure occurs during use, allow 3 minutes before restarting the unit.

After power is reinstated, restart the air conditioner. If the power was off for less than three minutes, be sure to wait at least three minutes before restarting the unit. If you restart the air conditioner within three minutes, a protective device in the unit may cause the compressor to shut off. This protective device will prevent cooling for about 5 minutes.

Memories of previous settings will be canceled and the unit will return to each initial setting.

• Dehumidifying function

The air conditioner removes moisture from the air in your room.

• Cooling operation under low temperatures: Is your unit freezing up?

The unit operates on inside and outside temperatures. Freezing can occur when the temperature is set close to 64

°F and when there are low outside temperatures, especially during the night hours. At these conditions, a further temperature drop may cause the unit to freeze. Setting the unit to a higher temperature will prevent it from freezing.

ENERGY EFFICIENCY TIPS

Setting the proper temperature.

For optimum energy efficiency, keep the difference between the inside and outside temperature within

10

°F(5°C). Do not keep the temperature setting any lower than is necessary for you to feel comfortable.

Generally, 78

°F to 80°F(26°C to 27°C) is a comfortable summer indoor temperature.

When you turn the unit on, do not set the temperature higher than the room temperature at start up as this will not allow the compressor to cycle and maintain a comfortable room temperature.

Avoid direct sunlight.

Close blinds, drapes or shades to keep out direct sunlight during cooling operation.

Keep the filter clean.

Keeping the filter clean greatly aids efficient operation. A dirty filter blocks the flow of air, making your air conditioner work harder and less efficiently. See page 18 on how to clean the filter.

Turn off unnecessary light.

Your air conditioner must remove the heat produced by your lights or other heat-producing appliances.

Turn off lights or appliances that are not in use.

Install your air conditioner in a shady location.

Direct sunlight on a window air conditioner increases its workload and will increase its operating cost.

Don't let cool air escape.

Close windows and outside doors. Do not keep doors open and let hot air rush in. Improperly installed air conditioners and improperly weatherstripped doors and windows will let hot air in and the cool air out.

Turn off air conditioner when no one is home.

Use only when necessary. The fewer hours a room air conditioner is used, the lower the operating cost.

9

HOW TO OPERATE

PARTS NAMES

UNIT

4

3

5

6

2

1

1

2

3

4

5

6

Front panel

Air inlet (Indoor side)

Louvers

Air outlet (Indoor side)

Exhaust lever

Control panel

CONTROL PANEL

7

8

9

10

11

12

11

12

7

8

9

10

Cabinet

Air outlet (Outdoor side)

Air inlet (Outdoor side)

Filter (Pull the filter handle to the right to remove.)

Filter handle

Power cord

2 1

3

F hr

SELECTOR

COOL / FAN

TEMP

TIMER

ON/OFF

ENERGY

SAVER

POWER

ON/OFF

4 5

10

1

2

3

4

5

Receiver window for remote control signal

Display

SELECTOR indicator

SELECTOR pad

TEMPERATURE setting pad

----

Lower temp.

----

Raise temp.

7

6 8

9

10

11

6

7

8

9

10

11

TIMER ON/OFF pad

TIMER indicator

ENERGY SAVER pad

ENERGY SAVER indicator

POWER ON/OFF pad

POWER indicator

HOW TO OPERATE

COOLING OPERATION

SELECTOR indicator

POWER indicator

F hr

SELECTOR

COOL / FAN

TEMP TIMER

ON/OFF

ENERGY

SAVER

POWER

ON/OFF

1

Touch POWER ON/OFF pad.

• The unit is preset at 74

°F and HIGH

COOL. This will show in the display when the power is first turned on.

• POWER indicator and SELECTOR indicator (COOL) will light.

POWER ON/OFF pad

2

To turn off the unit, touch POWER

ON/OFF pad again

.

• POWER indicator and SELECTOR indicator will go off.

TO CHANGE TEMPERATURE SETTING

F hr

SELECTOR

COOL / FAN

TEMP TIMER

ON/OFF

ENERGY

SAVER

POWER

ON/OFF

TEMPERATURE setting pad

During cooling operation

Touch the TEMPERATURE setting pad to adjust the temperature setting.

---

Lower temp.

---

Raise temp.

• Temperature can be set within the range of 64

°F to 86°F.

• Display will change as you touch the pad.

NOTE:

The latest temperature setting will be memorized and will appear on the display the next time the unit is turned on.

• In cases of power outages or when the unit is disconnected; when the power is restored or the unit is plugged in, the unit and display will return to the preset conditions of 74

°F and HIGH

COOL. The unit will not automatically turn back on. The user must touch POWER ON/OFF to resume opertion.

11

HOW TO OPERATE

TO CHANGE FAN SPEED AND OPERATION MODE

SELECTOR indicator

F hr

SELECTOR

COOL / FAN

TEMP TIMER

ON/OFF

ENERGY

SAVER

POWER

ON/OFF

SELECTOR pad

During operation

Touch SELECTOR pad and select the operation mode and fan speed.

• SELECTOR indicator and display will light in order as you touch.

HIGH COOL

LOW FAN

MED COOL

MED FAN

LOW COOL

HIGH FAN

NOTES ON OPERATION MODE:

MODE SELECTOR DISPLAY

HIGH COOL

COOL

MED COOL

COOL

LOW COOL

COOL

FAN

HIGH FAN

MED FAN

FAN

LOW FAN

FAN

Cooling operation with high fan speed.

Cooling operation with medium fan speed.

Cooling operation with low fan speed.

Fan only operation with high fan speed.

Fan only operation with medium fan speed.

Fan only operation with low fan speed.

• The latest operation mode will be memorized and the selector indicator and display will light when the unit is turned on.

• In fan only operation, the temperature display will go off.

• When the SELECTOR is changed to fan only operation from cooling operation, it will take 5 seconds for the compressor to stop.

12

HOW TO OPERATE

ENERGY SAVER

During normal operation, the thermostat automatically controls cooling and the fan runs continuously. When the ENERGY SAVER is selected, the thermostat automatically controls cooling and the fan automatically stops when the compressor is not operating. (Fan will stop 30 seconds after the compressor stops. After the fan stops, the fan is programmed to rotate for approx. 2 minutes to detect room temperature. This will occur within a 20 min time span.)

During cooling operation

1

Touch ENERGY SAVER pad.

• ENERGY SAVER indicator will light.

F hr

SELECTOR

COOL / FAN

TEMP TIMER

ON/OFF

ENERGY

SAVER

POWER

ON/OFF

2

To cancel, touch ENERGY SAVER pad again.

• ENERGY SAVER indicator will go off.

ENERGY SAVER pad

ENERGY SAVER indicator

NOTE: ENERGY SAVER cannot be set during fan only (HIGH FAN, MED FAN, LOW FAN) operation.

TO CHANGE AIR FLOW DIRECTION

Adjust the louvers to change the direction of air flow for uniform and efficient cooling of the room.

Horizontal louvers

Adjusts UP/DOWN air flow

Vertical louvers

Adjusts LEFT/RIGHT air flow

EXHAUST

If air in your room is stale, set the

EXHAUST lever to the OPEN position.

This will exhaust stale air to the outside.

The EXHAUST lever should normally be kept in the CLOSED position during cooling for maximum efficiency.

CLOSED

EXHAUST Lever

OPEN

13

HOW TO OPERATE

ON TIMER OPERATION

• This unit has a built-in timer that can be programmed to start the unit up to 12 hours in advance.

You can set the timer to start in increments of 30 minutes (0.5 hours) up to 9.5 hours in advance of the start time, or in 1 hour increments from 10 to 12 hours in advance of the start time.

• The unit will start automatically according to your setting.

SELECTOR indicator

F hr

SELECTOR

COOL / FAN

TEMP TIMER

ON/OFF

ENERGY

SAVER

POWER

ON/OFF

TIMER ON/OFF pad

TIMER indicator

(If you wish to start the operation

6 hours and 30 minutes later, set the delay time as shown above.)

When the unit is not operating

1

Touch the TIMER ON/OFF pad to set the delayed start time.

• The time setting will change as you touch the pad. The display will change as follows;

Preset(0.5h)

Previous setting

0.5h

1.0h 1.5h

10h

CL(cancel) 12h 11h

• The timer will be set, 5 seconds after the

TIMER ON/OFF pad is touched for the last time.

• SELECTOR indicator and TIMER indicator will light.

• The time display will count down the remaining time.

• The unit will start when the set time expires.

The temperature setting will be displayed.

TO CANCEL THE TIMER SETTING

Touch the TIMER ON/OFF pad again after the timer is set, or press the TIMER ON/OFF pad until CL(cancel) appears on the display.

14

NOTES FOR TIMER SETTING AND OPERATION:

• After setting the TIMER, change the temperature and fan speed settings as shown on pages 11 and 12. When the temperature is set in the timer mode, the temperature will show in the display for 5 seconds and then return to the time display.

• The last setting used will be memorized and will appear on the display the next time you operate the unit with the TIMER function.

• If a power failure occurs while the ON or OFF TIMER is set, the TIMER memory will be cancelled and will not resume even after power is reinstated. The unit will not automatically start.

• OFF TIMER OPERATION can also be set with the REMOTE CONTROL.

HOW TO OPERATE

OFF TIMER OPERATION

• This unit has a built-in timer that can be programmed to shut the unit off up to 12 hours in advance.

You can set the timer to stop in increments of 30 minutes (0.5 hours) up to 9.5 hours in advance of the stop time, or in 1 hour increments from 10 to 12 hours in advance of the stop time.

• The unit will stop automatically according to your setting.

F hr

SELECTOR

COOL / FAN

TEMP TIMER

ON/OFF

ENERGY

SAVER

POWER

ON/OFF

TIMER ON/OFF pad

TIMER indicator

(If you wish to stop the operation

10 hours later, set the delay time as shown above.)

When the unit is operating

1

Touch the TIMER ON/OFF pad to set the delayed stop time.

• The time setting will change as you touch the pad. The display will change as follows;

Preset(0.5h)

Previous setting

0.5h

1.0h 1.5h

10h

CL(cancel) 12h 11h

• The timer will be set, 5 seconds after the

TIMER ON/OFF pad is touched for the last time.

• TIMER indicator will light.

• The time display will count down the remaining time.

• The unit will stop when the set time expires.

All indicators and displays will go out.

TO CANCEL THE TIMER SETTING

Touch the TIMER ON/OFF pad again after the timer is set or, press the TIMER ON/OFF pad until

CL(cancel) appears on the display.

15

HOW TO OPERATE

USING THE REMOTE CONTROL

INSTALLING BATTERIES

Use two size-AAA (R03) batteries.

1

Remove the battery compartment cover.

2

Insert the batteries in the compartment, making sure the and polarities are properly aligned.

Battery compartment cover

3

Replace the cover.

NOTES:

• The battery life is approximately one year with normal use.

• When you replace the batteries, always use two new ones of the same type.

• If the remote control does not operate normally after replacing the batteries, take out the batteries and replace them again after 30 seconds.

• If you will not be using the unit for a long time, remove the batteries from the remote control.

ATTACHING THE REMOTE CONTROL HOOK

Cabinet

• Remove the backing from the remote control hook.

• Attach the hook onto the left side of the unit's cabinet.

• To prevent loss, hook the remote control on the cabinet when not in use.

Front Panel

Remote control hook

16

HOW TO USE THE REMOTE CONTROL

Point the remote control towards the unit's receiver window and press the desired button. A beep will sound when the unit receives the signal.

• Make sure no objects, such as curtains, block the receiver window.

• The remote control operates from up to 20 feet (6 meters) away.

• The beep will also sound when each pad on the control panel is touched.

CAUTION:

• Do not expose the receiver window to direct sunlight. This can adversely affect its operation. In such case, close the curtains to block the sunlight.

• Use of a fluorescent lamp in the same room may interfere with the transmission of the signal.

• The unit may be affected by signals emitted from the remote control of a television, VCR or other equipment used in the same room.

• Do not leave the remote control exposed to direct sunlight or near a heater. Protect the remote control from moisture and shock which can discolor or damage it.

HOW TO OPERATE

OPERATING WITH THE REMOTE CONTROL

TRANSMITTER

POWER

ON/OFF

TEMP.

TEMP.

SELECTOR

SET TIMER/OFF

POWER ON/OFF button

Push to start or stop the operation.

TEMPERATURE setting button

TEMP.

TEMP.

---

Raise temp. setting 1

°F at a time.

---

Lower temp. setting 1

°F at a time.

SELECTOR button

Push to change fan speed and operation mode.

Fan speed and operation mode selections are shown to the right.

SET TIMER/OFF button

Push to set delay "OFF" timer during operation.

HIGH COOL

MED COOL

LOW COOL

HIGH FAN

MED FAN

LOW FAN

• The time setting will change as you push the button. The display will change as follows;

Preset(0.5h)

Previous setting

0.5h

CL(cancel)

1.0h

12h

1.5h

11h

10h

• The last OFF time setting is memorized by the unit and will appear on the display when the button is pushed.

• The timer will be set, 5 seconds after the SET TIMER/OFF button is pushed for the last time.

• If you wish to cancel the timer, push the SET TIMER/OFF button again after the time is set or, push the SET TIMER/OFF button until CL (cancel) appears on the display. A double beep will sound when the timer is cancelled.

• The "ON" TIMER cannot be set with the remote control.

It can only be activated by the TIMER ON/OFF pad on the unit's control panel ( See page 14 ).

To change temperature setting when ON/OFF timer is in use

1. Push a TEMPERATURE setting button.

The current set temperature will be recalled on the unit's display.

2. Use the TEMPERATURE setting buttons to set the new temperature.

The new set temperature will show on the display for 5 seconds and return to the time display.

17

18

CLEANING THE FILTER

If the filter is clogged with dust, the amount of air flow will be reduced, resulting in poor cooling performance. The filter should be cleaned every10 days. At the beginning of every cooling season or after a long period of inactivity, clean the filter before starting the unit.

1

REMOVE THE FILTER

Gently pull the filter handle to the right and slide the filter out from the unit.

2

CLEAN THE FILTER

To remove dust from the filter, use a vacuum cleaner or wash it in clean water.

If the filter is very dirty, wash it with detergent and rinse carefully with clean water. Dry the filter with a soft cloth.

Do not expose the filter to heat or dry it in direct sunlight.

3

RE-INSTALL THE FILTER

Align the filter behind the front panel.

Grasp the filter handle and gently push the filter back into place.

Never operate the unit without installing the filter. It may result in serious damage to the unit.

CLEANING OF THE FRONT PANEL AND CABINET

To clean the front panel and cabinet, wipe with a soft, dry cloth or with a cloth moistened with a mild soap. Rinse carefully by wiping with a damp cloth and dry completely.

Avoid splashing the unit with water. Excess water can damage electrical insulation and result in danger.

Never use harsh chemicals or abrasive cleaners on any part of the unit. To avoid damage to the unit, do not use hot water (120

°F(50°C) or more) when cleaning.

OILING OF THE COMPRESSOR AND FAN MOTOR IS

UNNECESSARY

The compressor is permanently lubricated and is hermetically sealed. The fan motor is lifetime sealed and does not require oiling.

BEFORE CALLING FOR SERVlCE

IF YOUR AIR CONDITIONER DOES NOT OPERATE PROPERLY, PLEASE CHECK

THE FOLLOWING ITEMS BEFORE CALLING FOR SERVICE.

AIR CONDITIONER DOES NOT OPERATE AT ALL

• Is the unit plugged in or is the plug loose?

• Is the fuse blown or the circuit breaker tripped?

• Did you restart the unit within 3 minutes after a power failure? If the power was off for less than 3 minutes, and you restarted the air conditioner within 3 minutes, a protective device may cause the compressor to shut off, preventing cooling for about 5 minutes.

AIR CONDITIONER DOES NOT PROPERLY COOL

• Is the SELECTOR set to fan only (HIGH FAN, MED FAN, LOW FAN)mode?

Cooling will not take place in the fan only mode. Change the SELECTOR setting.

• Is the filter clogged with dust?

A dirty filter can cause the cooling coils to freeze. If this happens, clean the filter and replace. Run the air conditioner on the MED FAN setting until all ice dissipates.

• Is the temperature set properly?

If your room is too warm, adjust the temperature setting lower.

If your room is too cool, adjust the temperature setting higher.

• Is the EXHAUST lever in the OPEN position.?

The lever should be in the CLOSED position during cooling.

• Is the window exposed to direct sunlight?

Close curtains or blinds to minimize solar energy heating the room.

• Are the windows or doors open?

Close all windows and doors for maximum cooling.

TIMER DOES NOT WORK PROPERLY

• If a power failure occurs while the ON or OFF TIMER is set, the TIMER setting will be cancelled and will not resume even after the power is reinstated. This is the normal operation for this unit.

NOTE: WATER IN BOTTOM OF TRAY

• Water will collect in the bottom tray of the unit. This is normal. Water condenses on the evaporator coil at the front of the unit and is channeled to the rear where it is picked up by the condenser fan.

The water is blown onto the condenser coil fins and this creates a "splashing" noise which is normal.

If excess water builds up in this tray it will drain outside through a grooved channel in the tray.

SOUNDS

• The operating sound may seem rather loud for 2 to 3 minutes when the unit is first turned on. This is the sound of the compressor's start-up and is normal.

• A soft, swishing noise can be heard immediately after the unit is turned on or off, and also during operation. This is the sound of the refrigerant flowing inside the unit.

IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNAL

• Check the remote control batteries. Replace if necessary.

• Try to send the signal again with the remote control pointed directly at the unit's receiver window.

• Check whether the remote control batteries are installed with the polarities properly aligned.

19

20

SHARP ELECTRONICS CORPORATION

Sharp Plaza, Mahwah, New Jersey 07430-2135

SHARP CORPORATION

Osaka, Japan

Printed in Thailand

TINSEA344JBRZ 02MO TH 1

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project