COMPUTER INTERFACE ADAPTOR
WJ-PC10
ASK OF ELECTRIC SHOCK
CO NOT OPEN
CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO
NOT REMOVE COVER (OR BACK). NO USER SER-
VICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.
The lightning flash with arrowhead
symbol, within an equilateral triangle,
is ‘intended to alert the user to the
presence of uninsulated “dangerous
voltage” within the products
enclosure that may be of sufficient
magnitude to constitute a risk of elec-
eecananonanereromercarvor raat Eas ana NANN For U.S.A...
Warning:
This equipment generates and uses radio frequency
energy and if not installed and used properly, i.e., In
strict accordance with the instruction manual, may
cause harmful interference to radio communications.
It has been tested and found to comply with the limits
for a Class A computing device pursuant to Subpart
J of Part 15 of FCC Rules, which are designed to pro-
vide reasonable protection against such interference
when operated in a commercial environment.
mmm mk kd A AAA EA FEA EAE ENA FAA EAN O FAO FAP ны
o rerve ratiasnaasnananenerenarenmenmerereavrarroreoaacacarenmDa For CANADA ,..
This digital apparatus does not exceed the Class A
limits for radio noise emissions from digital apparatus
set out in the Radio Interference Regulations of the
Canadian Department of Communications.
FUFA ET EEE EEE eau EEE EEE EEE EEE EF
The serial number of this product may be found on
the bottom of the unit.
You should note the serial number of this unit in the
SA 1965 tric shock to persons. space provided and retain this book as a permanent
record of your purchase to aid identification in the
The exclamation point within an event of theft.
equilateral triangle is intended to alert
the user to the presence of important Model No.
operating and maintenance (servicing)
instructions in the literature accompa- Serial No.
o nying the appliance.
SA 1966
WARNING:
TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
CONTENTS
PREFACE 2... 00rreraerrrereara recrea 1
FEATURES cc a 1
PRECAUTIONS KEG 2
MAJOR OPERATING CONTROLS AND
THEIR FUNCTIONS 22.222440 a aa see nas ee eau» 3
CABLE CONNECTION ...... 0D 6
SETTING UP OF THE UNIT ........ 2.20 ass 7
GENERAL CONDITION FOR INSTALLATION
OF WJ-PC10 ....L12400 0e ae na ana a nana ana anne 10
SYSTEM APPLICATION ........ 2.2000 002 12
SYSTEM ERROR TABLE ........ 000000... 18
SPECIFICATIONS 2.120 a ess aa ana eee ee ee eee 21
PREFACE
The Computer Interface Adaptor WJ-PC10 is designed
for use with Panasonic System 300 to expand the system
capability. The system data used in the System 300 can
be transmitted over the telephone line using this unit. The
distance between the camera site and control site can
be extended in the present System 300.
FEATURES
e The automated system operation, such as sensor
system, card access system or some other control
systems, can be achieved incorporated with the
computer. (PC-mode)
The distance between the camera site and control
site can be extended in the present System
300.(Extension-mode)
PRECAUTIONS
Do not attempt to disassemble the unit. In order to
prevent electrical shock, do not remove screw or
covers. There are no user-serviceable parts inside.
Do refer all servicing to qualified service personnel.
Do not abuse the unit. Avoid striking, shaking, etc. it
could be damaged by improper handling or storage.
Do handle the unit with care.
Do not use strong or abrasive detergents when
cleaning the unit. Do use a dry cloth to clean the
unit when dirty. In case the dirty is hard to remove,
use mild detergent and wipe gently.
Do not expose the unit to water or moisture and do
not operate in wet area. Do take immediate action if
ever the unit does become wet, Turn the power off
and refer servicing to qualified service personnel.
Moisture can damage the unit and also create the
danger of electrical shock.
Do not use the unit in an extreme environment where
high temperature or high humidity exist. Use the unit
under conditions where temperatures are within
14°F - 122°F (—10°C - +50%C) and humidity is
below 95%.
The input power source must be 12V DC. Connect
to a class 2 power supply only.
Caution:
To prevent fire or shock hazard, the UL listed
wire VW-1, style 1007 should be used for the
cable for 12VDC Input Terminal.
Important:
- All necessary procedures with regard to
install this unit should be made by qualified
service personnel or system installer who
is experienced in Panasonic System 300
installation. |
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS
90 VO © - 0
[_SYS pata |[ Rs-27 = asar seo ZO >
CORO || EEE О Оба» |
| | æ O
Computer Interface Adaptor WJ-PC 10
ue = -
1. Power ON/OFF Button (POWER ON/OFF) 2. System Data Receiving indicator (SYS DATA RX)
Note: This indicator blinks irregularly for both PC-mode
The DC power is supplied all the time from and Extension-mode while this unit receives the
external DC power supply unit even if this system data.
power button is turned off.. Disconnect the Note:
DC power when this unit is not in use for a long When the system data error occurs, this LED
period. blinks in 0.5 sec. interval. See page 18 for
details.
3. System Data Transmitting Indicator
(SYS DATA TX)
This indicator blinks irregularly for both PC-mode
and Extension-mode while this unit sends the
system data out.
Note:
When the system data error occurs, this LED
blinks in 0.5 sec. interval. See page 18 for
details.
. RS-232C Receiving Indicator (RS-232 RX)
This indicator blinks irregularly for both PC-mode
and Extension-mode while this unit receives
RS-232C signal from another unit such as Modem
or computer,
Note:
When the system data error occurs, this LED
blinks in 0.5 sec. interval. See page 18 for
details.
. RS-232C Transmitting indicator (RS-232 TX)
This indicator blinks irregularty for both PC-mode
and Extension-mode while this unit transmits
RS-232C signal to another unit such as Modem
or computer,
Note:
When the system data error occurs, this LED
blinks in 0.5 sec. interval or the error is
indicated on the monitor TV. See page 18 for
details.
. RS-232C Connector (RS-232C)
Connect this connector with Modem unit, computer
and so on.
Pin configuration
1. GND (Frame ground)
SD (TXD)
RD (RXD)
RS (RTS)
CS (CTS)
DR (DSR)
. SG (Signal ground)
20, ER (DIR)
Other pins are not used.
Nook WN
. Controller Number Selection Switch
{CONTROLLER UNIT NO.)
This switch is used to identify the Controller
Unit Number in the system. Up to five(5)
WV-CU300/WJ-PC10 can be installed in the
system.
7-1. PC-mode
1. The numbers other than 1-5 on this switch are
not used.
2. Do not duplicate numbers with other
WV-CU300/WJ-PC10.
7-2. Extension-mode
1, Set this switch to number O for every WJ-PC10.
8. Data Clock Switch (DATA CLOCK SND/RCYV)
When the data clock is supplied to this Data
Input/Output Connector(9), turn this switch to the
RCV position. And when the data clock is sent out
from this connector, turn this switch to the SND
position,
Note:
When the system is separated in some sites
connecting with the modem units and so on,
the SND-RCV connection should be made in
each site. In each site, only one unit should be
set as the SND unit and the other units should
be set as the RCV unit,
9.
10.
Data Input/Output Connector (DATA IN/OUT 1/2)
These connectors send out or accept the system
data to/from other system components in System
300. Also the data clock signal is either sent out or
received through these connectors.
12VDC Input Terminals (DC 12V IN)
Supply 12VDC power to this terminals.
Caution:
Use class 2 power supply only.
CABLE CONNECTION
2-2.
RS-232C cable
Use RS-232C standard cable (straight connection)
of up to 49ft (15m) to connect between WJ-PC10
and other unit such as Modem, computer and so on.
When the cable is to be made locally, refer to the
Pin configuration of RS-232C Connector on page 4.
System data bus connection
. Cable connection
The two BNC connectors for DATA IN/QUT on
the WJ-MP404, WJ-SQ508 and WV-CU300 are
internally connected and are identical. The System
data bus connection is looped through all units
with the first and last units being automatically
terminated with 75 ohms and all other units being
Hi-Z loop through.
Data Clock Switch selection
Set the Data Clock Switch on the first unit
connected to the System data bus to the "SND"
so that this unit is the Data Clock supplier. Set the
Data Clock Switch on all other units to the "RCV"
position.
Data are transmitted and received to and from each
unit connected to the System data bus, in addition
to the Data Clock, through the single coaxial cable.
WVv-CU300 RCV
DATA IN/OUT — DATA CLOCK
о ©- © y SNOf M)RCYV
DATA IN/OUT
WJ-50508
SND
| DATA CLOCK
O SND [@] rcv
DATA INJOUT
WJ-PC10
WJ-MP404 SND
DATAIN/OUT DATA CLOCK
о © SND [|] RCV
WJ-PC10 RCV
DATA IN/OUT DATA CLOCK
о © О © sno[iacy
DATA IN/OUT
WJ-SQ508
SETTING UP OF THE UNIT
Remove four screws fixing the top cover and remove top
cover. There are switches and connectors on the board
as shown below, Set up unit to meet your system. <Rear Panel Side>
e (1 1
Remove 4 screws. )
ENT
[CNIT]
==
<Front Parte! Side>
1. SW3: Selection of the baud rate of RS-232C signal.
Turn on one of 6 switches.
No.1
No.2
No.3
No.4
No.5
No.6
1200 bps
2400 bps
4800 bps
9600 bps (Factory set up)
19200 bps
38400 bps
2. SW4 : Selection of the function.
The factory preset switch position is OFF for all
switches,
Select ON or OFF position according to your system.
2-1. Operation mode : PC-mode
SW No. Function Switch position
No.1 Parity bit ON:None OFFYes
No.2 Parily mode ON:EVEN OFF:ODD
No3 Stop bit ON:2bit OFF:1 bit
Nod Data bit ON:8hit ОРЕЛ БН
No.5 Alarm selection ON:stop OFF:release
No.6 Main/Sub selection Should be OFF position
No.7 DTE/DCE selection ON:DTE OFF:DCE
No.8 Operation mode Should be OFF position
Note:
When the Alarm switch (No.5) is turned on,
the alarm signal to the RS-232C line can
be stopped. However, the alarm signal
can be confirmed by operating computer vía
WJ-PC10.
2-2. Operation mode : Extension-mode
SW No. Function Switch position
No.1 Parity bit ‚ Should be OFF position
No2 Parity mode Should be OFF position
No3 Stop bit Should be OFF position
No.4 Data bit Should be OFF position
No.5 Xon/Xolf control Should be OFF position
No6 Main/Sub selection ON:Sub OFF:Main
No.7 DTE/DCE selection ON:DTE OFF:DCE
No8 Operation mode Should be ON position
Note on Extension-mode: The Modem units should
be set as follows.
Parity - None
Stop bit - | bit
Data bit - B8bits
Xon/Xotf - Notused
3. Main/Sub selection on SW4 (No.6) in the Extension-
mode.
The WJ-PC10 located in the control site should be
set to Main (OFF) position and the WJ-PC10 located
in the camera site should be set to the Sub (ON)
position as shown. |
Sysiem data [system dala
wy-Pc10 | Modem |- —- Modem E----- Modem !__4 wy-PCto |
Sub Main
| Camera site — LL Control site ———
4. CN10/CN11 : Selection of RS-232C cable
The Straight RS-232C Cable should be used with
WJ-PC10.
1. When WJ-PC10 is used as a DCE mode,
connect the cable on the board to the CN10
(STR).
2. When WJ-PC10 is used as a DTE mode,
connect the cable on the board to the CN11
(CROSS),
GENERAL CONDITION FOR INSTALLATION OF WJ-PC10
1. Inthe Extension-mode a pair of WJ-PC10 which are However, another pair of WJ-PC10 can not be
designated for the Main and Sub is allowed to install — installed in the same system data bus as shown.
in one system data bus.
WJ-MP404
System data
| WJ-PC10 H Modem т 5 WJ-PC10 В Modem = Modem
WV-CU300
System data
WJ-PC10
Sub Main
| Camera site | | Control site —-
2. In the Extension-mode, the WJ-PC10 which are However, both Main's and Sub's can not be
designated for either Main's or Sub's are allowed to connected at the same time on both sites.
connect in different site at one site only.
4
| WJ-MP404 | | WwY-CU300 |
| Sub Main |
| W1-50508 WJ-PC10 Modem: -—-—-—-——— | Modem — W.J-PC10 |
L
Sub Main
WJ-SQ508 WJ-PC10 | Modem | ——————
| WJ-MP404 | WY-CU30D
Camera site - L — —cantrol site———
-_10-
WJ-MP404 |
Sub
| | Г |
WJ-50508 WJ-PC10 Modem ————— - Modem WJ-PC10
Sub
Main
WJ-50508 WJ-FC10 E— Modem ———=— — = Modem | WJ-PC10
WV-CU300
L | Lo Control site —
Camera site
3. In the Extension-mode, the possible number of
WV-CU300 will be fixed according to the baud rate
of RS-232C.
Baudrate Number of WV-CU300
1200 bps None
2400 bps 1pc.
4800 bps Less than 2pcs.
9600 bps Less than 4pcs.
19200 bps Less than 5pcs.
38400 bps Less than 5pcs.
«11 =
4. The maximum time delay between the Main SYSTEM APPLICATION
WJ-PC10 and Sub WJ-PC10 should be less than
O.1sec. If the time delay is more than O.1sec, the Important:
WJ-8Q508 on the Sub WJ-PC10 will not operate 1. Refer to the Operating Instructions of the System
correctly. 300 products for the connection and setting up of
the system.
2. When the Modem is connected with the telephone
WJ-MP404 line, the Modem should be set to the "exclusive
| line mode” due to WJ-PC10 does not have dialing
function,
| WJ-SQ508 | 3. The recommended baud rate of the RS-232C signal
| | is more than 9600 bps if quick response is required
such as the pan/tilt or focus/zoom of the lens
operation.
| WJ-PC10 H Modem | -- Modem — WJ-PC10 |
Sub Main
1. PC-mode system
In this application, the System 300 can be remotely
controlled or operated by the computer through
WJ-PC10. The another system may connect with
the computer.
important:
The communication software should be
necessary to operate your system. Piease
contact with your dealer or system installer.
| Time delay less than 0.1 sec N
re
— 12 -
PC MODE SYSTEM
Reciever ~~ ne
————_—
Computer
WJ-MP404
(SND)
System Data
(RCV) WJ-PC10
Camera
WJ-5Q508
a
RS-232C
- 13 -
Extension-mode 1 system Note:
In this application, the camera sites and the contro! The setting up of the Data Clock Switch
site are connected with one video transmitting (SND/RCV) should be made for the camera site
line. This application is recommended when every and control site individualty.
camera site is located closely.
WJ-MP404
(SND)
8
ВАН
114]
sue г
wJ-5QS508
\ Camera sites
~ 14 —
Converters k-——— — — — =
Video +
System data WJ-PC10
(RCV)
RS-232C
Modem
Telephone line
Optical fiber/
micro-wave
or other trans-
mitting method
— d fl —— — — — »| Converters
Monitor TY
System
data
RS-232C
| — Modem
\ Controi site
+
-15-
Extension-mode 2 system Note:
In this application, the camera sites and control site The setting up of the Data Clock Switch
are connected with some video transmitting lines. (SND/RCV) should be made for the camera
This application is recommended when the 4 video sites and control site individually.
signals are reuired simultaneously using WJ-450
and soon,
Optica! fiber/
micro-wave
Converters or other trans-
Video [ |] mitting method
WJ-MP404 ds | TT О
SND
tid oo a
System | |
data
WJ-PC 10
(RCV}
LL) | Mod Telephone line
одет | - — — — ———
Camera sites
- 16 —
Video
Monitor TV
WJ-SQ508
Converters
-
WJ-PC10 System data
(RCV)
—— —— Modem a a
RS-232C —
Contro! site
- 17-
SYSTEM ERROR TABLE
LED indication
Cause
Trouble points
SYS DATA RX No data sync Data Clock Switch on all units are set to
; RCV position.
Broken system data line with "RCV"
WJ-PC10.
Duplicated data sync Duplicated "SND" position of WJ-PC10 with
other units,
SYS DATA TX Wrong Controller Unit No. Controller Unit No. is set either 0, 6,7, 8 or
9 in PC-mode.
Controller Unit No. is set other than O in
Extenston-mode.
Duplicated Controller Unit No. Controller Unit No. duplicated with
WJ-PC10 in PC-mode.
RS-232 RX 75% termination error Broken or non-termination of system data
line with "SND" WJ-PC10.
RS-232 TX WJ-MP404 site error in PC-mode Duplicated "SND” position of WJ-PC10 with
WJ-MP404.
Duplicated "Unit No." of system components.
Broken or non-termination of system data
line.
-18-
1.
PC-mode
Open Open
(3) f*—— Non-termination ” (3) [*—— Non-termination
{worn — aos]
(SND) (RCV)
[1) X Broken (1) X Broken
2) X Broken (2) X Broken
| WJ-PC10 | | WJ-PC10 |
(ВСУ) (SND)
Trouble point Error indication LED on Trouble point Error indication LED on
WJ-PC10 WJ-PC10
(1) Broken SYS DATA RX (1) Broken RS-232 FX
(2) Broken SYS DATA BX (2) Broken RS-232 RX
(3) Non-termination RS-232 TX (3) Non-termination RS-232 RX
- 19 -
2. Example in Extension-mode
Broken Broken No.1 Broken Broken
(SND) 11) (2) (ACV) (3-7 (3)-2
Monitor TY
=
KIT (RCV) (4)
Trouble points Error indication
No.1 WJ-PC10 | No.2 WJ-PC10 Monitor TV
(1) Broken SYS DATA RX — —
(2) Broken SYS DATA RX — —
{3)-1 Broken No error indication available.
(3)-2 Broken LED on RS-232 RX does not light —
(3)-3 Broken when no receiving data.
(4) Broken — RS-232 RX CU ERROR: A1
e Refer to operating instructions of WV-CU300 for CU ERROR: A1.
— 20 —
SPECIFICATIONS
Power source: 12V DC, 0.18A
Input/output: Data In/Out; 1Vp-p/75ohms x2 (BNC)
RS-232C; 25pin D-sub .
Controls: Controller Number Selection Switch
Data Clock Switch
Ambient operating temperature: 14°F - 122°F (—10°C - 450°C)
Ambient operating humidity: Les than 95%
Dimensions: 5-7/16"(W) x 1-3/4"{H) x 7-5/16"(D)
[138(W) x 44(H} x 185(D)mm]
Weight: 1.8 Ibs (0.8 kg)
Weight and dimensions shown are approximate.
Specifications are subject to change without notice.
- 21 -
Panasonic
Broadcast & Television Systems Company
Division of Matsushita Electric Corporation of America
CLOSED CIRCUIT VIDEO EQUIPMENT DIVISION
Executive Office: One Panasonic Way, Secaucus, New Jersey 070984
Regional Offices:
Northeast: 43 Hartz Way, Secaucus, NJ D7094 (201) 348-7303
Southeast: 1854 Shackleford Court, Suite 115, Norcross, CA 30003 (404) 717-6835
Midwest: 1707 North Randall Road, Elgin, IL 60123 (708) 468-5200
Southwest: 4500 Amon Carter Blvd. Ft. Worth, TX 76155 [B17) 685-1117
Western: 6550 Katella Ave., Cypress, CA 90630 (714) 373-7265
N0193-0
YWV8QA2962AN
Printed in Japan
(N) 15

advertisement

Related manuals

advertisement