Mitsubishi Electric Speed Series Amplifier SPA SPA150.4 Instruction manual
Mitsubishi Electric Speed Series Amplifier SPA SPA150.4 is a high-performance amplifier designed for a wide range of industrial applications. It offers precise control of AC servo motors and spindle motors, enabling smooth and efficient operation of machinery. The SPA150.4 is equipped with advanced features that enhance system performance, reliability, and ease of use.
Advertisement
Advertisement
MELDAS is a registered trademark of Mitsubishi Electric Corporation.
Other company and product names that appear in this manual are trademarks or registered trademarks of their respective companies.
Introduction
Thank you for selecting the Mitsubishi numerical control unit.
This instruction manual describes the handling and caution points for using this AC servo/spindle.
Incorrect handling may lead to unforeseen accidents, so always read this instruction manual thoroughly to ensure correct usage.
Make sure that this instruction manual is delivered to the end user.
Always store this manual in a safe place.
All specifications for the MDS-C1-SPA Series are described in this manual. However, each CNC may not be provided with all specifications, so refer to the specifications for the CNC on hand before starting use.
Notes on Reading This Manual
(1) Since the description of this specification manual deals with NC in general, for the specifications of individual machine tools, refer to the manuals issued by the respective machine manufacturers. The "restrictions" and "available functions" described in the manuals issued by the machine manufacturers have precedence to those in this manual.
(2) This manual describes as many special operations as possible, but it should be kept in mind that items not mentioned in this manual cannot be performed.
i
Precautions for safety
Please read this manual and auxiliary documents before starting installation, operation, maintenance or inspection to ensure correct usage. Thoroughly understand the device, safety information and precautions before starting operation.
The safety precautions in this instruction manual are ranked as "WARNING" and "CAUTION".
DANGER
When there is a potential risk of fatal or serious injuries if handling is mistaken.
WARNING
When operator could be fatally or seriously injured if handling is mistaken.
CAUTION
When a dangerous situation may occur if handling is mistaken leading to medium or minor injuries, or physical damage.
Note that some items described as
CAUTION
may lead to major results depending on the situation. In any case, important information that must be observed is described.
The numeric control unit is configured of the control unit, operation board, servo drive unit, spindle drive unit, power supply, servomotor and spindle motor, etc.
In this section "Precautions for safety", the following items are generically called the "motor".
• Servomotor
• Spindle motor
In this section "Precautions for safety", the following items are generically called the "unit".
• Servo drive unit
• Spindle drive unit
• Power supply unit
ii
WARNING
1. Electric shock prevention
Do not open the front cover while the power is ON or during operation. Failure to observe this could lead to electric shocks.
Do not operate the unit with the front cover removed. The high voltage terminals and charged sections will be exposed, and can cause electric shocks.
Do not remove the front cover even when the power is OFF unless carrying out wiring work or periodic inspections. The inside of the servo drive units is charged, and can cause electric shocks.
Wait at least 15 minutes after turning the power OFF before starting wiring, maintenance or inspections. Failure to observe this could lead to electric shocks.
Ground the servo drive unit and servomotor with Class C (former class 3) grounding or higher.
Wiring, maintenance and inspection work must be done by a qualified technician.
Wire the servo drive unit and servomotor after installation. Failure to observe this could lead to electric shocks.
Do not touch the switches with wet hands. Failure to observe this could lead to electric shocks.
Do not damage, apply forcible stress, place heavy items on the cables or get them caught.
Failure to observe this could lead to electric shocks.
CAUTION
1. Fire prevention
Install the servo drive units, servomotors and regenerative resistor on noncombustible material. Direct installation on combustible material or near combustible materials could lead to fires.
Shut off the power on the servo drive unit side if the servo drive unit fails. Fires could be caused if a large current continues to flow.
When using a regenerative resistor, provide a sequence that shuts off the power with the regenerative resistor's error signal. The regenerative resistor could abnormally overheat and cause a fire due to a fault in the regenerative transistor, etc.
The battery unit could heat up, ignite or rupture if submerged in water, or if the poles are incorrectly wired.
2. Injury prevention
Do not apply a voltage other than that specified in Instruction Manual on each terminal.
Failure to observe this item could lead to ruptures or damage, etc.
Do not mistake the terminal connections. Failure to observe this item could lead to ruptures or damage, etc.
Do not mistake the polarity ( + , – ). Failure to observe this item could lead to ruptures or damage, etc.
The servo drive unit's fins, regenerative resistor and servomotor, etc., may reach high temperatures while the power is ON, and may remain hot for some time after the power is turned OFF. Touching these parts could result in burns. iii
CAUTION
3. Various precautions
Observe the following precautions. Incorrect handling of the unit could lead to faults, injuries and electric shocks, etc.
(1) Transportation and installation
Correctly transport the product according to its weight.
Use the servomotor's hanging bolts only when transporting the servomotor. Do not transport the servomotor when it is installed on the machine.
Do not stack the products above the tolerable number.
Do not hold the cables, axis or detector when transporting the servomotor.
Do not hold the connected wires or cables when transporting the servo drive units.
Do not hold the front cover when transporting the servo drive units. The unit could drop.
Follow this Instruction Manual and install in a place where the weight can be borne.
Do not get on top of or place heavy objects on the unit.
Always observe the installation directions.
Secure the specified distance between the servo drive unit and control panel's inner wall, and between other devices.
Do not install or run a servo drive unit or servomotor that is damaged or missing parts.
Do not block the intake or exhaust ports of the servomotor provided with a cooling fan.
Do not let foreign objects enter the servo drive units or servomotors. In particular, if conductive objects such as screws or metal chips, etc., or combustible materials such as oil enter, rupture or breakage could occur.
The servo drive units and servomotors are precision devices, so do not drop them or apply strong impacts to them. iv
CAUTION
Store and use the units under the following environment conditions.
Environment
Ambient temperature
Ambient humidity
Storage temperature
Storage humidity
Atmosphere
Conditions
Servo drive unit Servomotor
0°C to +55°C (with no freezing) 0°C to +40°C (with no freezing)
90%RH or less
(with no dew condensation)
80%RH or less
(with no dew condensation)
–15°C to +70°C
90%RH or less (with no dew condensation)
Indoors (where unit is not subject to direct sunlight), with no corrosive gas, combustible gas, oil mist, or dust
Altitude
Vibration 4.9m/s
2
1,000m or less above sea level
(0.5G) or less
Follows each specifications manual
Securely fix the servomotor to the machine. Insufficient fixing could lead to the servomotor slipping off during operation.
Always install the servomotor with reduction gear in the designated direction. Failure to do so could lead to oil leaks.
Structure the rotary sections of the servomotor so that it can never be touched during operation. Install a cover, etc., on the shaft.
When installing a coupling to a servomotor shaft end, do not apply an impact by hammering, etc. The detector could be damaged.
Do not apply a load exceeding the tolerable load onto the servomotor shaft. The shaft could break.
Store the motor in the package box.
When inserting the shaft into the built-in IPM motor, do not heat the rotor higher than
130°C. The magnet could be demagnetized, and the specifications characteristics will not be ensured.
If the unit has been stored for a long time, always check the operation before starting actual operation. Please contact the Service Center or Service Station. v
CAUTION
(2) Wiring
Correctly and securely perform the wiring. Failure to do so could lead to runaway of the servomotor.
Do not install a condensing capacitor, surge absorber or radio noise filter on the output side of the servo drive unit.
Correctly connect the output side (terminals U, V, W). Failure to do so could lead to abnormal operation of the servomotor.
Do not directly connect a commercial power supply to the servomotor. Failure to observe this could result in a fault.
Servodrive unit Servodrive unit
COM
(24VDC)
COM
(24VDC)
When using an inductive load such as a relay, always connect a diode as a noise measure parallel to the load.
Control output signal
RA
Control output signal
RA
When using a capacitance load such as a lamp, always connect a protective resistor as a noise measure serial to the load.
Do not reverse the direction of a diode which connect to a DC relay for the control output signals to suppress a surge. Connecting it backwards could cause the drive unit to malfunction so that signals are not output, and emergency stop and other safety circuits are inoperable.
Do not connect/disconnect the cables connected between the units while the power is ON.
Securely tighten the cable connector fixing screw or fixing mechanism. An insecure fixing could cause the cable to fall off while the power is ON.
When using a shielded cable instructed in the connection manual, always ground the cable with a cable clamp, etc.
Always separate the signals wires from the drive wire and power line.
Use wires and cables that have a wire diameter, heat resistance and flexibility that conforms to the system. vi
CAUTION
(3) Trial operation and adjustment
Check and adjust each program and parameter before starting operation. Failure to do so could lead to unforeseen operation of the machine.
Do not make remarkable adjustments and changes as the operation could become unstable.
(4) Usage methods
Install an external emergency stop circuit so that the operation can be stopped and power shut off immediately.
Turn the power OFF immediately if smoke, abnormal noise or odors are generated from the servo drive unit or servomotor.
Unqualified persons must not disassemble or repair the unit.
Never make modifications.
Reduce magnetic damage by installing a noise filter. The electronic devices used near the servo drive unit could be affected by magnetic noise.
Use the servo drive unit, servomotor and regenerative resistor with the designated combination. Failure to do so could lead to fires or trouble.
The brake (magnetic brake) assembled into the servomotor are for holding, and must not be used for normal braking.
There may be cases when holding is not possible due to the magnetic brake's life or the machine construction (when ball screw and servomotor are coupled via a timing belt, etc.).
Install a stop device to ensure safety on the machine side.
After changing the programs/parameters or after maintenance and inspection, always test the operation before starting actual operation.
Do not enter the movable range of the machine during automatic operation. Never place body parts near or touch the spindle during rotation.
Follow the power supply specification conditions given in the separate specifications manual for the power (input voltage, input frequency, tolerable sudden power failure time, etc.).
Set all bits to "0" if they are indicated as not used or empty in the explanation on the bits.
Do not use the dynamic brakes except during the emergency stop. Continuous use of the dynamic brakes could result in brake damage.
If a breaker is shared by several power supply units, the breaker may not activate when a short-circuit fault occurs in a small capacity unit. This is dangerous, so never share the breakers. vii
CAUTION
(5) Troubleshooting
If a hazardous situation is predicted during power failure or product trouble, use a servomotor with magnetic brakes or install an external brake mechanism.
Use a double circuit configuration
Shut off with the servomotor brake control output.
Shut off with NC brake control PLC output.
that allows the operation circuit for the magnetic brakes to be operated
Servomotor
MBR EMG even by the external emergency stop signal.
Magnetic brake
24VDC
Always turn the input power OFF when an alarm occurs.
Never go near the machine after restoring the power after a power failure, as the machine could start suddenly. (Design the machine so that personal safety can be ensured even if the machine starts suddenly.)
(6) Maintenance, inspection and part replacement
Always carry out maintenance and inspection after backing up the servo drive unit's programs or parameters.
The capacity of the electrolytic capacitor will drop over time. To prevent secondary disasters due to failures, replacing this part every five years when used under a normal environment is recommended. Contact the Service Center or Service Station for replacement.
Do not perform a megger test (insulation resistance measurement) during inspections.
If the battery low warning is issued, save the machining programs, tool data and parameters with an input/output unit, and then replace the battery.
Do not short circuit, charge, overheat, incinerate or disassemble the battery.
(7) Disposal
Dispose of this unit as general industrial waste. Note that MDS Series unit with a heat dissipating fin protruding from the back of the unit contains substitute Freon. Do not dispose of this type of unit as general industrial waste. Always return to the Service Center or Service
Station.
Do not disassemble the servo drive unit or servomotor parts.
Dispose of the battery according to local laws.
(8) General precautions
The drawings given in this Specifications and Maintenance Instruction Manual show the covers and safety partitions, etc., removed to provide a clearer explanation. Always return the covers or partitions to their respective places before starting operation, and always follow the instructions given in this manual. viii
CONTENTS
1. Introduction
1-1 Spindle drive system configuration................................................................................................... 1-2
1-1-1 System configuration ................................................................................................................. 1-2
1-1-2 Unit outline type ......................................................................................................................... 1-3
1-2 Explanation of type ........................................................................................................................... 1-4
1-2-1 Spindle motor type ..................................................................................................................... 1-4
1-2-2 Spindle drive unit type ............................................................................................................... 1-5
1-2-3 Power supply unit type............................................................................................................... 1-6
1-2-4 AC reactor type .......................................................................................................................... 1-7
2. Specifications
2-1 Spindle motor.................................................................................................................................... 2-2
2-1-1 Specifications............................................................................................................................. 2-2
2-1-2 Output characteristics ................................................................................................................ 2-7
2-2 Drive unit......................................................................................................................................... 2-12
2-2-1 Installation environment conditions.......................................................................................... 2-12
2-2-2 Spindle drive unit ..................................................................................................................... 2-12
2-2-3 Power supply unit..................................................................................................................... 2-17
2-2-4 AC reactor................................................................................................................................ 2-18
2-2-5 D/A output specifications for spindle drive unit........................................................................ 2-19
2-2-6 Explanation of each part .......................................................................................................... 2-20
2-3 Restrictions and precautions .......................................................................................................... 2-22
2-3-1 Layout of unit ........................................................................................................................... 2-22
2-3-2 Precautions for installing multiple power supply units ............................................................. 2-23
2-3-3 Precautions when installing multiple spindle drive units to one power supply unit ................. 2-24
3. Characteristics
3-1 Spindle motor.................................................................................................................................... 3-2
3-1-1 Environmental conditions........................................................................................................... 3-2
3-1-2 Shaft characteristics................................................................................................................... 3-2
3-2 Drive unit characteristics................................................................................................................... 3-3
3-2-1 Environmental conditions........................................................................................................... 3-3
3-2-2 Heating value ............................................................................................................................. 3-4
4. Dedicated Options
4-1 Orientation option ............................................................................................................................. 4-2
4-1-1 Magnetic sensor......................................................................................................................... 4-3
4-1-2 Spindle side detector (OSE-1024-3-15-68, OSE-1024-3-15-68-8) ........................................... 4-6
4-2 Cables and connectors ..................................................................................................................... 4-8
4-2-1 Cable connection diagram ......................................................................................................... 4-8
4-2-2 List of cables and connectors .................................................................................................... 4-9
5. Peripheral Devices
5-1 Selection of wire ............................................................................................................................... 5-2
5-1-1 Example of wires by unit ............................................................................................................ 5-2
5-2 Selection the AC reactor, contactor and no-fuse breaker ................................................................ 5-4
5-2-1 Standard selection ..................................................................................................................... 5-4
5-2-2 Selection of contactor for changing over spindle motor drive wire ............................................ 5-5
5-3 Earth leakage breaker ...................................................................................................................... 5-6
5-4 Branch-circuit protection ................................................................................................................... 5-7
5-4-1 Circuit protector.......................................................................................................................... 5-7
5-4-2 Fuse protection .......................................................................................................................... 5-7
5-5 Noise filter ......................................................................................................................................... 5-8
5-6 Surge absorber ................................................................................................................................. 5-9
5-7 Speedometer and load meter ......................................................................................................... 5-10
5-8 Cable for peripheral control ............................................................................................................ 5-11
5-8-1 Cable for external emergency stop.......................................................................................... 5-11
Appendix 1. Outline Dimension Drawings
Appendix 1-1 Outline dimension drawings of spindle motor.................................................................A1-2
Appendix 1-1-1 SJ Series..................................................................................................................A1-2
Appendix 1-1-2 SJ-V Series ..............................................................................................................A1-5
Appendix 1-1-3 SJ-VS Series .........................................................................................................A1-15
Appendix 1-2 Unit outline dimension drawings...................................................................................A1-17
Appendix 1-2-1 Spindle drive unit ...................................................................................................A1-17
Appendix 1-2-2 Power supply unit ..................................................................................................A1-21
Appendix 1-2-3 AC rector................................................................................................................A1-25
Appendix 2. Cable and Connector Specifications
Appendix 2-1 Selection of cable ...........................................................................................................A2-2
Appendix 2-1-1 Cable wire and assembly.........................................................................................A2-2
Appendix 2-2 Cable connection diagram..............................................................................................A2-4
Appendix 2-3 Connector outline dimension drawings ..........................................................................A2-8
Appendix 3. Selection
Appendix 3-1 Selecting the power supply.............................................................................................A3-2
Appendix 3-1-1 Selecting according to the continuous rated capacity .............................................A3-2
Appendix 3-1-2 Selection example ...................................................................................................A3-3
Appendix 4. Explanation of Large Capacity Spindle Unit Specifications
Appendix 4-1 Explanation of large capacity spindle unit specifications ...............................................A4-2
Appendix 4-1-1 Outline......................................................................................................................A4-2
Appendix 4-1-2 List of units...............................................................................................................A4-2
Appendix 4-1-3 Selection of AC reactor (B-AL), contactor and NFB ................................................A4-2
Appendix 4-1-4 Outline dimension drawings.....................................................................................A4-3
Appendix 4-1-5 Panel cut dimension drawing...................................................................................A4-8
Appendix 4-1-6 Heating value...........................................................................................................A4-9
Appendix 4-1-7 Selecting the power capacity ...................................................................................A4-9
Appendix 4-1-8 Selecting the wire size .............................................................................................A4-9
Appendix 4-1-9 Drive unit connection screw size ...........................................................................A4-10
Appendix 4-1-10 Connecting each unit ...........................................................................................A4-10
Appendix 4-1-11 Restrictions ..........................................................................................................A4-12
Appendix 4-1-12 Parameters ..........................................................................................................A4-14
Appendix 4-1-13 Precautions ..........................................................................................................A4-14
Appendix 5. Explanation of Small Capacity Spindle Drive Unit Specifications
Appendix 5-1 Explanation of small capacity spindle drive unit specifications ......................................A5-2
Appendix 5-1-1 Outline......................................................................................................................A5-2
Appendix 5-1-2 List of units...............................................................................................................A5-2
Appendix 5-1-3 Outline dimension drawings.....................................................................................A5-2
Appendix 5-1-4 Drive unit specifications list......................................................................................A5-4
Appendix 5-1-5 Heating value...........................................................................................................A5-5
Appendix 5-1-6 Selecting the wire size .............................................................................................A5-5
Appendix 5-1-7 Drive unit connection screw size .............................................................................A5-5
Appendix 5-1-8 Restrictions ..............................................................................................................A5-6
Appendix 6. Compliance to EU EC Directives
Appendix 6-1 Compliance to EC Directives..........................................................................................A6-2
Appendix 6-1-1 European EC Directives ..........................................................................................A6-2
Appendix 6-1-2 Cautions for EC Directive compliance .....................................................................A6-2
Appendix 7. EMC Installation Guidelines
Appendix 7-1 Introduction .....................................................................................................................A7-2
Appendix 7-2 EMC instructions ............................................................................................................A7-2
Appendix 7-3 EMC measures ...............................................................................................................A7-3
Appendix 7-4 Measures for panel structure..........................................................................................A7-3
Appendix 7-4-1 Measures for control panel unit ...............................................................................A7-3
Appendix 7-4-2 Measures for door....................................................................................................A7-4
Appendix 7-4-3 Measures for operation board panel........................................................................A7-4
Appendix 7-4-4 Shielding of the power supply input section ............................................................A7-4
Appendix 7-5 Measures for various cables...........................................................................................A7-5
Appendix 7-5-1 Measures for wiring in panel....................................................................................A7-5
Appendix 7-5-2 Measures for shield treatment .................................................................................A7-5
Appendix 7-5-3 Servomotor power cable..........................................................................................A7-6
Appendix 7-5-4 Servomotor feedback cable .....................................................................................A7-6
Appendix 7-5-5 Spindle motor power cable ......................................................................................A7-7
Appendix 7-5-6 Spindle motor feedback cable .................................................................................A7-7
Appendix 7-6 EMC countermeasure parts............................................................................................A7-8
Appendix 7-6-1 Shield clamp fitting...................................................................................................A7-8
Appendix 7-6-2 Ferrite core ..............................................................................................................A7-9
Appendix 7-6-3 Power line filter ......................................................................................................A7-10
Appendix 7-6-4 Surge protector ......................................................................................................A7-15
Appendix 8. Instruction Manual for Compliance with UL/c-UL Standard
Appendix 8 Instruction Manual for Compliance with UL/c-UL Standard...............................................A8-2
Appendix 9. Compliance with China Compulsory Product Certification (CCC Certification) System
Appendix 9-1 Outline of China Compulsory Product Certification System...........................................A9-2
Appendix 9-2 First Catalogue of Products subject to Compulsory Product Certification .....................A9-2
Appendix 9-3 Precautions for Shipping Products .................................................................................A9-3
Appendix 9-4 Application for Exemption...............................................................................................A9-4
Appendix 9-5 Mitsubishi NC Product Subject to/Not Subject to CCC Certification ..............................A9-5
1. Introduction
1-1 Spindle drive system configuration .................................................................................................... 1-2
1-1-1 System configuration................................................................................................................... 1-2
1-1-2 Unit outline type........................................................................................................................... 1-3
1-2 Explanation of type............................................................................................................................. 1-4
1-2-1 Spindle motor type ...................................................................................................................... 1-4
1-2-2 Spindle drive unit type ................................................................................................................. 1-5
1-2-3 Power supply unit type ................................................................................................................ 1-6
1-2-4 AC reactor type ........................................................................................................................... 1-7
1 - 1
1. Introduction
1-1 Spindle drive system configuration
1-1-1 System configuration
Spindle drive unit
(MDS-C1-SPA)
Terminator
Power supply unit
(MDS-C1-CV)
• NC
• Sequencer
• DIO device
• Meter
Breaker or fuse
(Note)
Prepared by user
Contactor
(Note)
Prepared by user
AC reactor
(B-AL)
Spindle motor
NFB
(Note)
Prepared by user
Magnesensor or spindle side detector (1024p/rev encoder)
3-phase 200VAC power supply
1 - 2
1-1-2 Unit outline type
Unit outline type
D:260
200
Fin
1. Introduction
D:260
200
Fin
D:260
/263
200
Fin
Outline dimensions
[mm]
H:380 H:380 H:380
Heat dissipa- tion method
W:90
Wiring allowance at front: 50mm
Required ventilation space at back:
15mm
Heat radiated outside panel
(forced wind cooling)
W:120
Wiring allowance at front: 50mm
Required ventilation space at back:
15mm
Heat radiated outside panel
(forced wind cooling)
W:150
Wiring allowance at front: 50mm
Required ventilation space at back:
15mm (D2: 12mm)
Heat radiated outside panel
(forced wind cooling)
(Note) Refer to "Appendix 1 Outline dimension drawings" for detailed outline drawings.
For customers switching from MDS-A/B Series
The MDS-C1-SPA Series incorporates a highly efficient heat dissipating structure, so the depth of the fin section is smaller than the MDS-A/B Series. Units with an "S" at the end of the type have a smaller unit width than the MDS-A/B Series.
When designing the control panel with these unit outline dimensions, it may not be possible to mount the conventional drive unit.
1 - 3
1. Introduction
1-2 Explanation of type
1-2-1 Spindle motor type
MITSUBISHI
AC SPINDLE MOTOR
TYPE
SJ-V5. 5-01
SI CONT 4 POLE 3 PHASES
kW r/min
A(~) max
25
W I N D C O N N E C T U
3.7
2.8 8000 17
~ )
S2 30 min S3 50 %
137 - 162 V
kW
1500-6000 r/min
A(~) max
P OW E R FA C TOR 8 2 %
AMP INPUT( ~ )
4.1 8000 23 INSULATION CLASS F
AMB TEMP. 0-40ºC
SERIAL
DATE
FRAME D90F
IEC 34-1 1994
WEIGHT 49 kg IP 44
SPEC No.RSV00023*
MITSUBISHI ELECTRIC CORPORATION
A19103-01
MADE IN JAPAN
995291-01
Rating nameplate
(1) Standard spindle motor series
SJ-
(1) (2) (3)
(5) Z-phase detection
Symbol
Z-phase presences
(Note) Presence of the Z-phase applies only to the SJ and SJ-V Series.
None No Z-phase
M Z-phase present
(4) Special specifications
Symbol
Special specifications
None None
(Note) A number indicating the constant output range is indicated after the symbol for the wide range output.
Z
W
High-speed
Wide-range constant output
(3) Base speed
Symbol
Base speed
(Note) The SJ-V Series is indicated with a specification code (–01 to –99).
A
B
1500r/min
1150r/min
L
X
5000r/min
Special
(2) Short time rated output
Symbol
Short time rated output
Symbol
2.2
3.7
5.5
7.5
11
15
2.2kW
3.7kW
5.5kW
7.5kW
11kW
15kW
22
26
30
37
45
55
18.5
18.5kW
(1) Motor series
Symbol
Motor series
Short time rated output
22kW
26kW
30kW
37kW
(Note) The 3.7kW and smaller or the 37kW and larger capacities are available with the
MDS-B-SP Series.
Refer to Appendix 4 and Appendix 5 for details.
45kW
55kW
None
V
Large capacity
Compact medium to large capacity
VS Hollow shaft
(Note) Refer to the "MELDAS AC Spindle Built-in Series Standard Specifications" (BFN-14118-04) for details on the built-in spindle motor.
1 - 4
1. Introduction
1-2-2 Spindle drive unit type
Motor type
Rated input
Rated output
Current state
Serial No.
MITSUBISHI
TYPE
SERVO DRIVE UNIT
MDS-C1-SPA-55
POWER 5.5kW
INPUT 20A DC270-311V
0.2A 1PH 200/200-230V 50/60Hz
OUTPUT 18A 3PH 155V 0-240Hz
MANUAL# IB-1500148
S/W BNDXXXXXXXXX H/W VER. *
SERIAL# XXXXXXXXXXX DATE 00/01
MITSUBISHI ELECTRIC CORPORATION JAPAN
* X X X X X X X X X X X *
MDS-C1-
(1)
-
(2)
-
(3)
Rating nameplate
(3) Option
Symbol Compatible optional function
None None
R
D
T
Orientation function
Digital speed command input function
S-analog synchronous tapping function
RD Orientation function and digital speed command input function
RT Orientation function and S-analog synchronous tapping function
(2) Capacity
CapaOutline type (Note) The 3.7kW and smaller or
Symbol city (unit width) the 37kW and larger
55
75
110
150
185
(kW)
5.5
7.5
11
15
18.5
B1
(90mm wide)
C1
(120mm wide) capacities are available with the MDS-B-SP
Series.
Refer to Appendix 4 and
Appendix 5 for details.
220 22
D1
(150mm wide)
260
300
26
30
D2
(150mm wide)
(1) Spindle drive unit series
Symbol
Compatible motor rotation speed
Details
SPA
SPAH
Less than 10,000r/min
10,000r/min or more
Standard specifications
(Note 1) The 3.7kW and smaller or the 37kW and larger capacities are available with the MDS-B-SP
Series. Refer to Appendix 4 and Appendix 5 for details.
(Note 2) The Outline of unit is determined according to symbol in the above table “(2)” and it is not affected by the above table “(3)”.
1 - 5
1. Introduction
1-2-3 Power supply unit type
Motor type
Rated input
Rated output
Current state
Serial No.
MITSUBISHI
TYPE
POWER SUPPLY UNIT
MDS-C1-CV-150
POWER 15kW
INPUT 49A 3PH 200/200-230V 50/60Hz
0.2A 1PH 200/200-230V 50/60Hz
OUTPUT 58A DC270-311V
3040
S/W BND538W000A1 H/W VER. D
SERIAL# XXXXXXXXXXX DATE 02/09
MITSUBISHI ELECTRIC CORPORATION JAPAN
* X X X X X X X X X X X *
Rating nameplate
MDS-C1-
(1)
Power supply unit
(1) Motor type
MDS-C1-
Capacity
(kW)
Outline type
(unit width)
CV-37
CV-55
CV-75
CV-110
CV-150
CV-185
CV-220
CV-260
CV-300
CV-370
3.7
5.5
7.5
A2
(60mm wide)
11
B1
(90mm wide)
15
18.5
C1
(120mm wide)
22
26 D1
(150mm wide) 30
37
Compatible AC reactor
Compatible contactor
(Mitsubishi)
(Note 1)
Compatible NFB
(Mitsubishi)
(Note 1)
(Note 1) This is an optional part, and must be prepared by the user.
(Note 2) The 45kW and larger capacities are available with the MDS-B-CVE Series.
Refer to Appendix 4 for details.
1 - 6
1-2-4 AC reactor type
Type B-AL-7.5K
Nameplate
1. Introduction
Top surface of AC reactor
B-AL-
(1)
AC reactor
Motor type
B-AL-
Capacity
(kW)
Compatible power supply unit
7.5K 7.5
MDS-C1-CV-37
MDS-C1-CV-55
11K
MDS-C1-CV-75
11 MDS-C1-CV-110
MDS-C1-CV-150
18.5K 18.5
MDS-C1-CV-185
MDS-C1-CV-220
37K
MDS-C1-CV-300
37 MDS-C1-CV-370
1 - 7
2. Specifications
2-1 Spindle motor ..................................................................................................................................... 2-2
2-1-1 Specifications .............................................................................................................................. 2-2
2-1-2 Output characteristics.................................................................................................................. 2-7
2-2 Drive unit .......................................................................................................................................... 2-12
2-2-1 Installation environment conditions ........................................................................................... 2-12
2-2-2 Spindle drive unit ....................................................................................................................... 2-12
2-2-3 Power supply unit ...................................................................................................................... 2-17
2-2-4 AC reactor ................................................................................................................................. 2-18
2-2-5 D/A output specifications for spindle drive unit ......................................................................... 2-19
2-2-6 Explanation of each part............................................................................................................ 2-20
2-3 Restrictions and precautions............................................................................................................ 2-22
2-3-1 Layout of unit ............................................................................................................................. 2-22
2-3-2 Precautions for installing multiple power supply units............................................................... 2-23
2-3-3 Precautions when installing multiple spindle drive units to one power supply unit................... 2-24
2 - 1
2. Specifications
2-1 Spindle motor
2-1-1 Specifications
Spindle motor type
Base rotation speed
1500r/min Series
7.5-01
SJ-V
11-01 15-01 18.5-01 22-01 2.2-01 3.7-01 5.5-01 26-01
MDS-BMDS-B-
Compatible spindle drive unit type
SPAH-
MDS-B/C1-
22
SPAH-
37
SPA-55 SPA-75
SPA-
110
SPA-
150
SPA-
185
SPA-
220
SPA-
300
Continuous rating
1.5 2.2 3.7 5.5 7.5 11 15 18.5 22
[kW]
Output capacity
30-minute rating
50%ED rating 2.2 3.7 5.5 7.5 11 15 18.5 22 26
[kW]
Base speed
Maximum speed
Frame No.
GD 2
[r/min]
[r/min]
Continuous rated torque [N·m]
[kg·m 2 ]
Inertia [kg·m 2 ]
Tolerable radial load [N]
10000 8000
A90 B90 D90 A112 B112 A160 B160 C160
9.5 14.0 23.5 35.0 47.7 70.0 95.5 118 140
0.027 0.035
0.007 0.009
0.059
0.015
0.098
1500
0.12 0.23 0.23 0.32 0.38
980 1470 1960
Single-phase 200V
0.025
6000
0.03 0.06 0.06 0.08 0.10
3-phase 200V
2940
Cooling fan
Input voltage
Maximum power consumption
Ambient temperature
42W 40W 63W
Environ- ment
Ambient humidity
Atmosphere
Operation: 0 to 40°C (non freezing), Storage: –20 to 65°C (non freezing)
Operation: 90%RH or less (non condensing),
Storage: 90%RH or less (non condensing)
Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist, or dust
Insulation
Altitude
Operation: 1000 meters or less above sea level,
Storage: 1000 meters or less above sea level
110
Class F
(Note 1) The rated output is guaranteed at the rated input voltage (200/220/230VAC) to the power supply unit.
If the input voltage fluctuates and drops below 200VAC, the rated output may not be attained.
(Note 2) The 50%ED rating applies for a 10-minute cycle time consisting of ON for five minutes and OFF for five minutes.
(Note 3) The 3.7kW and smaller capacities are available with the MDS-B-SPA Series. Refer to Appendix 5 for details.
CAUTION
When replacing the SJ-V series by the conventional SJ series, the shorter L dimension is applied.
2 - 2
2. Specifications
Spindle motor type
Large capacity series
SJ- SJ-V
30A 37BP 45BP 55-01
Compatible spindle drive unit type
SPA-370 SPA-450
MDS-B-
SPA-550
Continuous rating
[kW]
22 30 37 45
Output capacity
30-minute rating
50%ED rating
[kW]
30 37 45 55
Base speed
Maximum speed
[r/min]
[r/min]
1500 1150
4500 3450
Frame No.
Continuous rated torque [N·m]
GD 2 [kg·m 2 ]
Inertia [kg·m
Tolerable radial load
Cooling fan
[N]
2 ]
Input voltage
Maximum power consumption
Ambient temperature
B160 B180 A200 A225
140 249 307 374
0.69 1.36 2.19 3.39
0.17 0.34 0.55 0.85
2940 4900 5880 5880
Single-phase 200V 3-phase 200V
Environ- ment
Ambient humidity
Atmosphere
Altitude
Operation: 0 to 40°C (non freezing), Storage: –20 to 65°C (non freezing)
Operation: 90%RH or less (non condensing),
Storage: 90%RH or less (non condensing)
Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist, or dust
Operation: 1000 meters or less above sea level,
Storage: 1000 meters or less above sea level
Insulation Class F
(Note 1) The rated output is guaranteed at the rated input voltage (200/220/230VAC) to the power supply unit.
If the input voltage fluctuates and drops below 200VAC, the rated output may not be attained.
(Note 2) The 50%ED rating applies for a 10-minute cycle time consisting of ON for five minutes and OFF for five minutes.
(Note 3) The 37kW and larger capacities are available with the MDS-B-SPA Series. Refer to Appendix 4 for details.
2 - 3
2. Specifications
Spindle motor type
Wide range (1:8) constant output series
Wide range constant output series
SJ-V SJ-
11-01 11-09 15-03 18.5-03
Compatible spindle drive unit type
SPA-110 SPA-185
MDS-C1-
SPA-220 SPA-260 SPA-300
Output
Continuous rating
3.7 5.5 7.5 9 11 19.5
[kW]
18.5 capacity 30-minute rating
50%ED rating [kW]
5.5 7.5 9 11 15 22 22
Base speed [r/min] 750
600
(800)
550
(600)
Maximum speed
Frame No.
[r/min]
B112 A160
47.1 70.0 95.5 115 140 239 294 Continuous rated torque [N·m]
GD 2 [kg·m 2 ]
Inertia [kg·m 2 ]
Tolerable radial load [N]
0.12 0.23 0.23 0.32 0.32 1.36 2.19
0.03 0.06 0.06 0.08 0.08 0.34 0.55
Cooling fan
Input voltage 3-phase 200V
Single- phase
200V
3-phase
200V
Maximum power consumption
Ambient temperature
Environ- ment
Ambient humidity
Atmosphere
Altitude
Operation: 0 to 40°C (non freezing), Storage: –20 to 65°C (non freezing)
Operation: 90%RH or less (non condensing),
Storage: 90%RH or less (non condensing)
Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist, or dust
Operation: 1000 meters or less above sea level,
Storage: 1000 meters or less above sea level
Insulation Class F
(Note 1) The rated output is guaranteed at the rated input voltage (200/220/230VAC) to the power supply unit.
If the input voltage fluctuates and drops below 200VAC, the rated output may not be attained.
(Note 2) The 50%ED rating applies for a 10-minute cycle time consisting of ON for five minutes and OFF for five minutes.
2 - 4
2. Specifications
Spindle motor type
High-speed series
SJ-V
3.7-02ZM 7.5-03ZM 11-06ZM 11-08ZM 22-06ZM 30-02ZM
Compatible spindle drive unit type MDS-B-
SPAH-110
MDS-B/C1-
Inertia [kg·m
Tolerable radial load [N]
2 ]
SPAH-150 SPA-185 SPA-220 SPA-300
Output capacity
Continuous rating
2.2 5.5 5.5 7.5 11
[kW]
30-minute rating
3.7
50%ED rating
(15min. rating)
[kW]
Base speed [r/min]
18.5
7.5 7.5 11 15 22
3000 1500
Maximum speed [r/min] 15000 12000 8000
Frame No.
Continuous rated torque [N·m]
GD 2 [kg·m 2 ]
A90 A112 B112 A160 B160
7.0 35.0 35.0 47.7 70.0 118
0.027 0.098 0.098 0.12 0.23 0.32
0.007 0.025 0.025 0.03 0.06 0.08
Cooling fan
Input voltage
Maximum power consumption
Single-phase
200V
3-phase 200V
42W 40W 63W
Ambient temperature
Environ- ment
Ambient humidity
Atmosphere
Altitude
Operation: 0 to 40°C (non freezing), Storage: –20 to 65°C (non freezing)
Operation: 90%RH or less (non condensing),
Storage: 90%RH or less (non condensing)
Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist, or dust
Operation: 1000 meters or less above sea level,
Storage: 1000 meters or less above sea level
Insulation Class F
(Note 1) The rated output is guaranteed at the rated input voltage (200/220/230VAC) to the power supply unit.
If the input voltage fluctuates and drops below 200VAC, the rated output may not be attained.
(Note 2) The 50%ED rating applies for a 10-minute cycle time consisting of ON for five minutes and OFF for five minutes.
(Note 3) The 3.7kW and smaller capacities are available with the MDS-B-SPA Series. Refer to Appendix 5 for details.
2 - 5
2. Specifications
Spindle motor type
Hollow shaft series
SJ-VS
7.5-03ZM 22-06ZM 30-02ZM
Compatible spindle drive unit type
SPAH-110 SPA-220 SPA-300
MDS-C1-
Continuous rating
[kW]
5.5 11 18.5
Output capacity
30-minute rating
50%ED rating
[kW]
7.5 15 22
Base speed
Maximum speed
Frame No.
[r/min]
[r/min]
1500 1500
12000 8000
A112 A160 B160
35.0 70.0 118 Continuous rated torque [N·m]
GD 2 [kg·m 2 ]
Inertia [kg·m 2 ]
Tolerable radial load
Cooling fan
Input voltage consumption
[N]
Maximum power
0.099 0.23 0.32
0.025 0.058 0.08
0 (Note 3)
Single-phase 200V
0 (Note 3)
3-phase 200V
0 (Note 3)
40W 40W
Ambient temperature
Ambient humidity
Operation: 0 to 40°C (non freezing),
Storage: –20 to 65°C (non freezing)
Operation: 90%RH or less (non condensing),
Storage: 90%RH or less (non condensing) Environ- ment
Atmosphere
Altitude
Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist, or dust
Operation: 1000 meters or less above sea level,
Storage: 1000 meters or less above sea level
Weight [kg] 65 115 140
Insulation Class F
(Note 1) The rated output is guaranteed at the rated input voltage (200 to 230VAC) to the power supply unit.
(Note 2) The 50%ED rating applies for a 10-minute cycle time consisting of ON for five minutes and OFF for five minutes.
(Note 3) Do not apply a radial load.
2 - 6
2. Specifications
2-1-2 Output characteristics
[Base rotation speed 1500r/min series SJ-V2.2-01] [Base rotation speed 1500r/min series SJ-V3.7-01]
2.2
3.7
15-minute rating
15-minute rating
1.5
1.3
0.9
Continuous rating
2.2
Continuous rating
1.3
5.5
4.1
3.7
2.8
0
0 1500 6000
Rotation speed [r/min]
10000
[Base rotation speed 1500r/min series SJ-V5.5-01]
15-minute rating
Continuous rating
7.5
5.5
4.1
0
0 1500 6000
Rotation speed [r/min]
10000
[Base rotation speed 1500r/min series SJ-V7.5-01]
15-minute rating
Continuous rating
11
8.3
7.5
5.6
0
0 1500 6000
Rotation speed [r/min]
8000
[Base rotation speed 1500r/min series SJ-V11-01]
15-minute rating
Continuous rating
15
11
8.3
0
0 1500 6000
Rotation speed [r/min]
8000
[Base rotation speed 1500r/min series SJ-V15-01]
15-minute rating
Continuous rating
18.5
15
13.9
11.3
0
0 1500 4500
Rotation speed [r/min]
6000
[Base rotation speed 1500r/min series SJ-V18.5-01]
15-minute rating
Continuous
22
18.5
16.5
13.9
0
0 1500 4500
Rotation speed [r/min]
6000
[Base rotation speed 1500r/min series SJ-V22-01]
15-minute rating
Continuous rating
0
0 1500 4500
Rotation speed [r/min]
6000
2 - 7
0
0 1500 4500
Rotation speed [r/min]
6000
2. Specifications
26
22
[Base rotation speed 1500r/min series SJ-V26-01]
30-minute rating
Continuous rating
30
22
0
0 1500
Rotation speed [r/min]
[Large capacity series SJ-30A]
30-minute rating
Continuous rating
6000
37
30
[Large capacity series SJ-37BP]
30-minute rating
Continuous rating
45
37
0
0 1500
Rotation speed [r/min]
[Large capacity series SJ-45BP]
4500
30-minute rating
Continuous rating
0
0
55
45
1150
Rotation speed [r/min]
[Large capacity series SJ-V55-01]
3450
30-minute rating
Continuous
0
0 1150
Rotation speed [r/min]
3450
0
0 1150
Rotation speed [r/min]
3450
2 - 8
2. Specifications
5.5
[Wide range (1:8) constant output series SJ-V11-01]
30-minute rating
3.7
Continuous rating
7.5
5.5
[Wide range (1:8) constant output series SJ-V11-09]
30-minute rating
Continuous rating
9
7.5
0
0 750 6000
Rotation speed [r/min]
[Wide range (1:8) constant output series SJ-V15-03]
30-minute rating
Continuous rating
11
9
0
0 750 6000
Rotation speed [r/min]
[Wide range (1:8) constant output series SJ-V18.5-03]
30-minute rating
Continuous rating
15
11
0
0 750 6000
Rotation speed [r/min]
[Wide range (1:8) constant output series SJ-V22-05]
30-minute rating
Continuous rating
0
0 750
Rotation speed [r/min]
6000
22
19.5
13
11.5
0
0 750 6000
Rotation speed [r/min]
[Wide range constant output series SJ-22XW5]
30-minute rating
Continuous rating
22
18.5
[Wide range constant output series SJ-22XW8]
30-minute rating
Continuous rating
0
600
Rotation speed [r/min]
3000 5000
2 - 9
0
0 500 600
Rotation speed [r/min]
4000
3.7
3
2.2
1.8
[High speed series SJ-V3.7-02ZM]
15-minute rating
Continuous rating
2. Specifications
7.5
6.3
5.5
4.6
[High speed series SJ-V7.5-03ZM]
15-minute rating
Continuous rating
7.5
5.5
0
0 3000
Rotation speed [r/min]
12000
[High speed series SJ-V11-06ZM]
15000
30-minute rating
Continuous rating
0
0 1500
Rotation speed [r/min]
10000 12000
[High speed series SJ-V11-08ZM]
11
7.5
30-minute rating
Continuous rating
15
11
0
0 1500
Rotation speed [r/min]
[High speed series SJ-V22-06ZM]
12000
30-minute rating
Continuous rating
22
18.5
0
0 1500
Rotation speed [r/min]
[High speed series SJ-V30-02ZM]
8000
30-minute rating
Continuous rating
0
0 1500
Rotation speed [r/min]
8000
0
0 1500
Rotation speed [r/min]
8000
2 - 10
7.5
5.5
[Hollow shaft series SJ-V7.5-03ZM]
30-minute rating
Continuous rating
2. Specifications
15
11
[Hollow shaft series SJ-V22-06ZM]
30-minute rating
Continuous rating
22
18.5
0
0 1500
Rotation speed [r/min]
[Hollow shaft series SJ-V30-02ZM]
12000
30-minute rating
Continuous rating
0
0 1500
Rotation speed [r/min]
8000
0
0 1500
Rotation speed [r/min]
8000
2 - 11
2. Specifications
2-2 Drive unit
2-2-1 Installation environment conditions
Common installation environment conditions for servo, spindle and power supply unit are shown below.
Ambient temperature
Operation: 0 to 55°C (with no freezing), Storage / Transportation: -15°C to 70°C (with no freezing)
Environ- ment
Ambient humidity
Atmosphere
Altitude
Vibration/impact
Operation: 90%RH or less (with no dew condensation)
Storage / Transportation: 90%RH or less (with no dew condensation)
Indoors (no direct sunlight)
With no corrosive gas, inflammable gas, oil mist or dust
Operation/Storage: 1000 meters or less above sea level, Transportation: 10000 meters or less above sea level
4.9m/s
2
(0.5G) / 49m/s
2
(5.0G)
2-2-2 Spindle drive unit
(1) Specifications
Spindle drive unit type
MDS-C1-SP-
MDS-C1-SPH-
Spindle drive unit MDS-C1-SP Series
55 75 110 150 185 220 260 300
Rated output
Output
Input
[kW]
Rated voltage [V]
Rated current [A]
Rated voltage [V]
Rated current [A]
Voltage [V]
Frequency [Hz]
3.7 5.5 7.5 11 15 18.5 22 26
155AC
18 26 37 49 63 79 97 130
270 to 311DC
200/200 to 230AC
50/60
Max. 0.2
MAX. 35
Control power
Current [A]
Rush current [A]
Rush conductivity time
[ms]
Earth leakage current [mA]
Control method
Braking
Speed command input
MAX. 6
6 (MAX. 15)
Sine wave PWM control method, current control method
Regenerative braking
Analog voltage ±10V (or +10V) MAX (input impedance approx.10kΩ), or digital (option) (12 bit binary, signed binary, BCD code 2 digits, BCD code 3 digits)
External analog output
Structure
Cooling method
0 to +10V, 2ch (speed meter output, load meter output, data for various adjustments)
Protection type (Protection method: IP20 [over all] / IP00 [Terminal block TE1])
Forced wind cooling (fin)
Weight [kg] 4.4
Heat radiated at rated output
[W]
5.7 6.5 6.3
108 137 181 235 342 366 483 620
Noise Less than 55dB
2 - 12
2. Specifications
(2) Spindle drive unit function specifications list
Function
None
S analog command voltage input±10V
S analog command voltage input 0 to +10V
Machine ready complete input
Forward run/reverse run command input
Override analog input
Torque limit 1 to 3 input
Gear selection1, 2 input
Alarm reset input
Emergency stop input
Speed selection 1 to 3 input
Override valid/invalid input
L coil selection input
Index forward run/reverse run input
Digital speed command input
S-analog high-speed tapping input
Sub-motor selection input
Speed meter output
Load meter output
Controller emergency output signal (contact output)
Pulse feedback output signal
Zero speed output signal
Up-to-speed output signal
Speed detection output signal
Torque reach output signal
In torque limit output signal
In motor forward run/reverse run output signal
In alarm output signal
In emergency stop output signal
In ready ON output signal
Current detect output signal
In coil changeover output signal
In L coil selected output signal
Alarm code output 1 to 4 signal
Orientation complete output signal
Positioning complete output signal
In 1-drive unit 2-motor changeover output signal
In sub-motor selection output signal
1-drive unit
2-motor
Spindle motor + spindle motor
(FR-TK unit is required.) changeover
Orientation
Digital speed command
Spindle motor + general-purpose motor
Magnetic sensor orientation (1 point)
Encoder orientation (multipoint
• index)
Motor PLG orientation (multipoint
• index )
12 bit binary
Signed binary
BCD3 digits
BCD2 digits
S-analog high- speed tapping
1024p/rev encoder specification
Motor PLG specification
Only for encoder orientation
1) Motor PLG orientation
2) Magnetic sensor orientation
3) Orientation not available
-
○
○
○
○
○
○
○
○
○
○
○
○
-
○
○
○
○
○
○
-
○
○
○
○
○
○
○
○
○
○
○
○
-
-
○
○
○
○
-
-
-
-
-
-
-
-
○
○
○
○
○
○
○
○
-
○
○
○
○
○
○
○
○
-
○
○
○
○
○
○
○
○
-
-
-
-
-
MDS-C1-SPA(H)-55~300*
*: Option symbol
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○ - - ○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○ - - ○
○ - - ○
○ - - ○
○
○
○
○
○
○
○
○
○
○
○
○
○
○ - ○ -
- ○ - ○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○ - - ○
○ - - ○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○ - ○ -
○ - ○ -
○ - ○ -
○ - ○ -
-
○
-
○
-
○
○
- - - - - ○
- - - - - ○
- - - ○ - ○
(Note 1) ○: available -: not available
(Note 2) For input excluding a basic function input, up to 12 points can be selected.
(Note 3) For output, up to 8 points can be selected for open emitter, and up to 6 points for open collector.
(Note 4) When using the override input terminal in S analog input, and when using the digital speed command, the override function can not be used.
(Note 5) When the orientation is not applied in the S-analog high-speed tapping specification, Z phase is not output from the pulse feedback signal. A position loop of spindle must be operated in the NC side.
2 - 13
2. Specifications
(3) Details on spindle drive unit function specifications
(a) Speed command input
1) Analog speed command input
Input voltage
Tolerable maximum input voltage
When using bipolar input
-10 to +10V
-15 to +15V
Input part connector, pin No.
Resolution
Between CN8A-No.7 pin (SE1) and
No.8 pin (SE2)
10V/ approx. 1940 divisions
(approx. 5.1mV)
When using unipolar input
0 to +10V
-15 to +15V
Between CN8A-No.17 pin (OR2) and
No.18 pin (OR1)
10V/ approx. 3570 divisions
(approx. 2.8mV)
(Note 1) Tolerable maximum input does not guarantee the speed linearity, but specifies the maximum voltage in which the drive unit will not be damaged.
2) Digital speed command input (option)
Binary
Signed binary BCD code 3digits BCD code 2digits
(12bit binary)
Input Contact input Sink
• source input available
Tolerable maximum input voltage
Input part connector
26.4V
Resolution
Motor maximum speed/4095
CN12
Motor maximum speed/2048
Motor maximum speed/999
Motor maximum speed/99
3) Speed selection input
With this function, 8 patterns of speed commands are selected using up to 3 bits in combination. Speed can be set with a parameter.
Input
Tolerable maximum input voltage
Input part connector
Minimum setting unit
(b) Override input
Speed selection
Contact input Sink and source input available
26.4V
Select maximum three of CN10 general-purpose input
1r/min
This function is valid when the override input contact set with the general-purpose input is turned ON.
Input voltage
Tolerable maximum input voltage
Input part connector, pin No.
Resolution
When using unipolar input
0 to +10V
-15 to +15V
Between CN8A-No.17 pin (OR2) and No.18 pin (OR1)
10V/ approx. 3570 divisions (approx. 2.8mV)
(Note 1) When using unipolar analog input, digital speed command input and speed selection for the speed command, the override function cannot be used.
2 - 14
2. Specifications
(c) Orientation function (spindle set position stop function) (option)
1) 1 point orientation
When the orientation signal is input, the spindle is stopped at the set position determined by an internal parameter.
When using external 1024p/rev encoder or motor PLG
When using magnetic sensor
Available stop position setting range
Stop position resolution
Repeated stop position accuracy
360°
360°/4096 divisions
±0.1°
±5° based on center of magnet and sensor
Approx. 5°/512 divisions
±0.1°
(Note 1) The repeated stop accuracy or resolution in the above table may not satisfy the accuracy according to backlash or friction torque, etc of machine.
(Note 2) When using magnetic sensor, the position accuracy or stop position range differs from the above table according to the installation radius.
(Note 3) Motor PLG orientation is possible only when the spindle and motor are coupled, when they are coupled at 1:1 with gears, or when they are coupled at 1:1 (pulley ratio) with a timing belt.
The Z phase signal must be provided to the motor speed detector.
2) Orientation
The spindle stop position in the orientation command input is changed arbitrarily using external 12 bits stop position command.
Available stop position setting range
Stop position resolution
Repeated stop position accuracy
When using external 1024p/rev encoder or motor PLG
360°(arbitrary according to external stop command)
360°/4096 divisions
±0.1°
(Note 1) The repeated stop accuracy or resolution in the above table may not satisfy the accuracy according to backlash or friction torque, etc of machine.
(Note 2) Motor PLG orientation is possible only when the spindle and motor are coupled, when they are coupled at 1:1 with gears, or when they are coupled at 1:1 (pulley ratio) with a timing belt.
The Z phase signal must be provided to the motor speed detector.
3) Multi-point indexing orientation
By setting the orient command and indexing forward run/reverse run to the general-purpose input, the stop position is changed arbitrarily without one rotation of the spindle.
Available stop position setting range
Stop position resolution
Repeated stop position accuracy
When using external 1024p/rev encoder or motor PLG
360°(arbitrary according to external stop command)
360°/4096 divisions
±0.1°
(Note 1) The repeated stop accuracy or resolution in the above table may not satisfy the accuracy according to backlash or friction torque, etc of machine.
(Note 2) Motor PLG orientation is possible only when the spindle and motor are coupled, when they are coupled at 1:1 with gears, or when they are coupled at 1:1 (pulley ratio) with a timing belt.
The Z phase signal must be provided to the motor speed detector.
2 - 15
2. Specifications
(d) S-analog high-speed tapping function (option)
By structuring the position loop in the NC side and synchronizing with the servo axis, tap cutting is carried out without using floating tap chuck. Setting the S-analog high-speed tapping input to the general-purpose input and adding the speed command voltage to the S-analog input section realize this function.
(e) 1-drive unit 2-motor changeover function
One spindle drive unit rotates two motors that are not used simultaneously. The motor drive wire is changed over with contactor, and signal wire with FR-TK to select which one to use.
When two motors must be rotated simultaneously, this function cannot be used.
(f) Coil changeover function
This function is used when using the coil changeover motor to gain an extensive constant output range without a gear. The coil selection signal is set to the general-purpose input, and a contactor for coil changeover, which is connected with the motor drive wire, is changed over through a compact relay by turning ON/OFF this signal.
For details on each specification above, refer to MDS-C1-SPA Instruction Manual.
2 - 16
2. Specifications
2-2-3 Power supply unit
Power supply unit type
Power supply unit MDS-C1-CV Series
MDS-C1-CV- 37 55 75 110 150 185 220 260 300 370
Rated output [kW]
Rated voltage [V]
Input
Output
Frequency [Hz]
Rated current [A]
Rated voltage [V]
Rated current [A]
Voltage
Frequency
[V]
[Hz]
Control power
Current [A]
Rush current [A]
Rush conductivity time
[ms]
Main circuit method
Structure
Cooling method
Weight [kg]
Heat radiated at rated output
[W]
Noise
200/200 to 230AC
50/60 Frequency fluctuation within ±3%
270 to 311DC
200/200 to 230AC
50/60
Max.0.2
MAX.35
MAX.6
Self- cooling
Converter with power regeneration circuit
Protection type (Protection method: IP20 [over all] / IP00 [Terminal block TE1])
Forced wind cooling
(internal)
Forced wind cooling (fin)
3.4 4.6 5.8 6.0 8.3 8.4 8.6 8.8
55 65 80 125 155 195 210 260 320 400
Less than 55dB
2 - 17
2. Specifications
2-2-4 AC reactor
An AC reactor must be installed for each power supply unit.
(1) Specifications
AC reactor type B-AL- 7.5K 11K
AC reactor
18.5K 30K 37K
Compatible power supply unit type
Rated capacity
(30-minute rating)
Rated voltage
MDS-C1-CV-
[kW]
[V]
7.5 11 18.5 30 37
200/200 to 230AC
Rated current
Frequency [Hz]
Ambient
[A] temperature
Ambient humidity
50/60 Frequency fluctuation within ±3%
Operation: -10 to 60°C (with no freezing),
Storage/Transportation: -10°C to 60°C (with no freezing)
Operation: 80%RH or less (with no dew condensation),
Storage/Transportation: 80%RH or less (with no dew condensation)
Environ- ment Atmosphere
Altitude
Indoors (no direct sunlight)
With no corrosive gas, inflammable gas, oil mist or dust
Operation/Storage: 1000 meters or less above sea level,
Transportation: 10000 meters or less above sea level
Vibration/impact 9.8m/s2 (1G) / 98m/s2 (10G)
Weight [kg] 3.6 3.0 5.2 6.0 10
2 - 18
2. Specifications
2-2-5 D/A output specifications for spindle drive unit
(1) D/A output specifications
Item Explanation
No. of channels
Output cycle
Output precision
Output voltage range
Output magnification setting
Output pin
Function
2ch
444µs (min. value)
8bit
0V to +5V (zero) to +10V,
0V to +10V for meter output
±1/256 to ±128-fold
CN9 connector
MO1 = Pin 9
MO2 = Pin 19
GND = Pin 1
Phase current feedback output function
U phase current FB : Pin 7
V phase current FB : Pin 17
3
4
5
6
Pin
1
2
7
8
9
10
(2) Setting the output data
No. Abbrev.
SP253 DA1NO D/A output channel 1 data No.
SP254 DA2NO D/A output channel 2 data No.
CN9 connector
Name
LG
UIFB
MO1
Pin
11
12
13
14
15
16
17
18
19
20
Name
VIFB
MO2
MDS-C1-SPA
Explanation
Input the No. of the data to be output to each D/A output channel.
1deg=(64000
÷65536)
No. Output data Original data unit
Output magnification standard setting value
(SP255, SP256)
0
0
8
8
Output unit for standard setting
Output cycle
0 ch1: Speedometer output ch2: Load meter output
1 –
5 –
80 Control input 1
81 Control input 2
82 Control input 3
83 Control input 4
84 Control output 1
85 Control output 2
86 Control output 3
87 Control output 4
10V=max. speed (Zero=0V)
10V=120% load (Zero=0V)
Rated 100%=4096
Rated 100%=4096
Depends on maximum speed 3.5ms
30-minute rating 12%/V
30-minute rating 20%/V
30-minute rating 20%/V
3.5ms
3.5ms
3.5ms
2 - 19
2. Specifications
2-2-6 Explanation of each part
(1) Explanation of each spindle drive unit part
<1> <2>
<3> <4>
<6> <5>
<7>
<9>
<8>
<10>
<11>
<12>
<13>
MDS-C1-SPA
<14>
The connector layout differs according to the unit being used. Refer to each unit's outline drawing for details.
Each part name
<1>
<2>
<3>
<4>
<5>
<6>
<7>
<8>
<9>
<10>
<11>
<12>
<13>
CN9A
CN4
CN5
CN6
CN12
CN8A
TE2
TE3
TE1
Name Description
LED --- Unit status indication LED
SW1,
PB1,
PB2,
PB3
---
SW1: Axis No. setting switch
PB1,2,3: Parameter setting button
General-purpose input output / DC power supply connection
CN10 --- connector
CN11 --- Orient position shift / general-purpose output connector
---
---
---
---
---
---
L+, L–
L11, L21
U, V, W
Personal computer connection / analog output connector
Power supply communication connector
Internal PLG encoder connection connector
Magnetic sensor / external encoder connection connector
Digital speed command / general-purpose output connector
Analog speed command / override / pulse output connector
Converter voltage input terminal (DC input)
Control power input terminal (single-phase AC input)
Motor power output terminal (3-phase AC output)
<14> PE Grounding terminal
(Note1) For customer switching from MDS-A/B Series
Make sure that PE terminal position has changed from UVW terminal to the bottom of the cooling fan.
Screw size
Type
Unit width (mm)
<11> L+, L–
<12> L11,L21
<13> U, V, W
<14>
04 to 37
M4 x 12
M4 x 8
Spindle drive unit MDS-C1-SPA-
55 to 110,150S 150 to 185
M6 x 14
M4 x 10
M5 x 12
M5 x 12
2 - 20
220 to 300
M8 x 14
M8 x 14
2. Specifications
(2) Explanation of each power supply unit part
<1>
<3>
<4>
<7>
<2>
<5>
<6>
<8>
<9>
<10>
<11>
The connector layout differs according to the unit being used. Refer to each unit's outline drawing for details.
Each part name
<1>
<2>
<3>
<4>
<5>
<6>
<7>
<8>
<9>
<10>
LED
SW1
---
TE2
TE3
Name Description
---
---
Power supply status indication LED
Power supply setting switch
CHARGE LAMP TE2 output charging/discharging circuit indication LED
L+, L–
L11, L21
Converter voltage output terminal (DC output)
Control power input terminal (single-phase AC input)
TE1 L1, L2, L3 Power input terminal (3-phase AC input)
<11> PE Grounding terminal
(Note1) CN23 is located at the bottom of the power supply unit.
(Note2) For customer switching from MDS-A/B Series
Make sure that PE terminal position has changed from UVW terminal to the bottom of the cooling fan.
Screw size
Type
Unit width (mm)
<7> L+, L–
<8> L11, L21
<9> MC1
<10> L1, L2, L3
<11>
37 to 75
Power supply unit MDS-C1-CV-
110 150 to 185 220 to 370
60 90 120 150
M6 x 16
M4 x 10
M4 x 10
M4 x 8
M4 x 10
M5 x 12
M5 x 8
M8 x 14
M8 x 14
2 - 21
2. Specifications
2-3 Restrictions and precautions
There are restrictions on the layout of spindle drive unit and power supply unit, and on sequence as follows.
When designing a power distribution box or creating sequence, always consider this section, and satisfy the following items.
2-3-1 Layout of unit
Arrange the spindle drive unit and power supply unit as follows.
(1) When installing one spindle drive
Spindle drive
Power supply
Link bar
(Front)
(2) When installing two spindle drives
1) When the total spindle drive output is 37kW or less
Spindle drive
Power supply
Spindle drive
Link bar
(Front)
2) When the total spindle drive output exceeds 37kW
Spindle drive
(1)
Power supply
(1)
Spindle drive
(2)
Power supply
(2)
(Front)
Link bar
(Note 1) Install each unit next to each other (vertical direction is not acceptable) with a 3cm or less clearance between spindle drive unit and power supply unit.
Note that this does not apply to the section between spindle drive (2) and power supply unit (1) shown in 2) of section (2).
(Note 2) When using section (2) 2), install an ACL (B-AL) on each power supply unit.
2 - 22
2. Specifications
2-3-2 Precautions for installing multiple power supply units
The methods for installing the two spindles are explained here as an example for installing multiple power supply units.
NC(PC) MDS-C1-SPA (No.1) MDS-C1-CV (No.1) MDS-C1-SPA (No.2) MDS-C1-CV (No.2)
C
N
10
11
12
8A
9A
C
N
4
C
N
4
C
N
10
11
12
8A
9A
C
N
4
C
N
4
L1, L2, L3
MC1
L+, L-
L11, L21
L1, L2, L3
MC1
L+, L-
L11, L21
MC MC
200VAC
NFB1(No.1) AC rector
(B-AL No.1)
Contactor (No.1) NFB1 (No.2) AC reactor
(B-AL No.2)
Contactor (No.2)
(1) Connecting the L+, L-, L11 and L21 link bars
Connect the L+ and L- link bars independently with C1-CV(No.1) and C1-CV(No.2) as shown above.
Make sure that both C1-CV link bars are not short-circuited when connected.
(2) Connecting and selecting NFB1, contactor and AC reactor
An NFB1, a contactor and an AC reactor must be installed independently to each power supply as shown above. (These cannot be shared.) Note that the contactor, excluding C1-CV-370, can be omitted.
(3) Connecting the MC1 terminal (A/B-CV)
When using the contactor, set the C1-CV rotary switch to "0", and when not using, set to "1".
2 - 23
2. Specifications
2-3-3 Precautions when installing multiple spindle drive units to one power supply unit
The methods for installing two spindle drive units to one power supply unit are explained here as an example.
NC(PC) MDS-C1-SPA (No.1) MDS-C1-CV MDS-C1-SPA (No.2)
C
N
10
11
12
8A
9A
C
N
4
C
N
9
C
N
4
C
N
10
11
12
8A
9A
C
N
4
MC1
L+, L-
L11, L21
L1, L2, L3
MC
200VAC
NFB1 AC reactor
(B-AL)
Contactor
(1) Connecting C1-CV and C1-SPA
Connect C1-CV CN4 and C1-SPA (No. 1) CN4 to C1-CV CN9 and C1-SPA (No.2) CN4. If C1-SPA is connected with three or more axes, leave CN4 for C1-SPA (No. 3) and following open.
Note that the C1-CV can be controlled (READY ON/OFF, alarm display, etc.) only by the spindle drive unit connected to C1-CV CN4.
(2) Make sure that the machine ready complete input turns ON and OFF simultaneously for all the spindle drive units. Do not allow the signal to turn ON and OFF for only one spindle drive unit.
(3) When turning the machine ready complete input OFF during an emergency stop, always have all the spindle drive units output the zero speed signal before turning the signal OFF.
(4) If an alarm occurs in one of the spindle drive units, turn OFF the machine ready complete input OFF for all the spindle drive units.
(5) When connecting three or more spindle drive units, install the large-capacity spindle drive units on both sides of the power supply unit.
2 - 24
3. Characteristics
3-1 Spindle motor ..................................................................................................................................... 3-2
3-1-1 Environmental conditions ............................................................................................................ 3-2
3-1-2 Shaft characteristics .................................................................................................................... 3-2
3-2 Drive unit characteristics .................................................................................................................... 3-3
3-2-1 Environmental conditions ............................................................................................................ 3-3
3-2-2 Heating value .............................................................................................................................. 3-4
3 - 1
3. Characteristics
3-1 Spindle motor
3-1-1 Environmental conditions
Environment Conditions
Ambient temperature
Ambient humidity
Storage temperature
Storage humidity
Atmosphere
0°C to +40°C (with no freezing)
90%RH or less (with no dew condensation)
–20°C to +65°C (with no freezing)
90%RH or less (with no dew condensation)
Indoors (no direct sunlight); no corrosive gases, inflammable gases, oil mist or dust
Altitude
Operation/storage: 1000m or less above sea level
Transportation: 10000m or less above sea level
3-1-2 Shaft characteristics
There is a limit to the load that can be applied on the motor shaft. Make sure that the load applied on the radial direction, when mounted on the machine, is below the tolerable values given below. These loads may affect the motor output torque, so consider them when designing the machine.
Spindle motor Tolerable radial load
SJ-V3.7-02ZM
SJ-V2.2-01, SJ-V3.7-01
SJ-V7.5-03ZM, SJ-V11-06ZM
SJ-V5.5-01, SJ-V11-08ZM
SJ-PMF01830-00
SJ-V7.5-01, SJ-V11-01
SJ-V22-06ZM, SJ-V30-02ZM, SJ-PMF03530-00
SJ-V11-09, SJ-V15-01, SJ-V15-03, SJ-V18.5-01, SJ-V18.5-03
SJ-V22-01, SJ-V22-05, SJ-V26-01, SJ-30A
SJ-22XW5
SJ-37BP
SJ-22XW8, SJ-45BP
SJ-V55-01
490 N
980 N
1470 N
1960 N
2940 N
3920 N
4900 N
5880 N
Radial load
The load point is at the one-half of the shaft length.
3 - 2
3. Characteristics
3-2 Drive unit characteristics
3-2-1 Environmental conditions
Environment Conditions
Ambient temperature
Ambient humidity
Storage temperature
Storage humidity
Atmosphere
Altitude
Vibration
0°C to +55°C (with no freezing)
90%RH or less (with no dew condensation)
–15°C to +70°C (with no freezing)
90%RH or less (with no dew condensation)
Indoors (no direct sunlight); no corrosive gases, inflammable gases, oil mist or dust
Operation/storage: 1000m or less above sea level
Transportation: 10000m or less above sea level
Operation/storage: 4.9m/s
2
(0.5G) or less
Transportation: 49m/s
2
(5G) or less
(Note) When installing the machine at 1,000m or more above sea level, the heat dissipation characteristics will drop as the altitude increases. The upper limit of the ambient temperature drops 1°C with every 100m increase in altitude. (The ambient temperature at an altitude of 2,000m is between 0 and 45°C.)
3 - 3
3. Characteristics
3-2-2 Heating value
Each heating value is calculated with the following values.
The values for the spindle drive unit apply for the continuous rated output. The values for the power supply unit include the AC reactor's heating value.
Servo drive unit
Type
MDS-C1-
Heating value [W]
Inside panel
Outside panel
Power supply unit
Type
MDS-C1-
Heating value [W]
Inside panel
Outside panel
SPA- 55
SPA- 75
SPA-110
SPA-150S
SPA-150
SPA-185
SPA-220
SPA-260
SPA-300
CV-370
21 34
23 42
25 55
26 99
29 126
33 162
35 175
40 220
46 274
54 346
(Note 1) The values for the spindle drive unit are the heating value at the continuous rated output.
(Note 2) The total heating value for the power supply includes the heating value for the AC reactor.
(Note 3) The total heating value for the unit is the total sum of the heating values for the above corresponding units which are mounted in the actual machine.
Example) When the CV-185, SP-185 units are mounted
Unit total heating value (W) =195+242=437(W)
3 - 4
4. Dedicated Options
4-1 Orientation option ............................................................................................................................... 4-2
4-1-1 Magnetic sensor .......................................................................................................................... 4-3
4-1-2 Spindle side detector (OSE-1024-3-15-68, OSE-1024-3-15-68-8) ............................................. 4-6
4-2 Cables and connectors ...................................................................................................................... 4-8
4-2-1 Cable connection diagram .......................................................................................................... 4-8
4-2-2 List of cables and connectors...................................................................................................... 4-9
4 - 1
4. Dedicated Options
4-1 Orientation option
Select the orientation option to be required for the spindle control based on the following table.
For each control function, availability of use differs depending on the specifications in the NC side, so also refer to the manuals of NC side.
(a) No-variable speed control
(When spindle and motor are directly coupled or coupled with a 1:1 gear ratio)
Spindle control item
Control specifications
Without orientation option
Motor PLG
Motor PLG with Z-phase
With orientation option
Motor PLG with Z-phase
Magnetic sensor
Spindle side detector
(1020p/rev encoder)
{ Speed control
Normal cutting control
Constant surface speed control (lathe)
Thread cutting (lathe)
Orientation control
S-analog high-speed synchronous tap control
1-point orientation control
Multi-point orientation control
Orientation indexing
Standard synchronous tap
Synchronous tap after zero point return
(Note 1) { : Control possible
× : Control not possible
{
{
×
×
×
×
{
×
{
{
{
×
×
×
{
{
{
{
{
{
{
{
{
This normally is not used for no-variable speed control.
(Note 2) The S-analog high-speed synchronous tap control is an option deferent from orientation. For details, refer to “2-2-2 (2)
Spindle drive unit function specifications list”. Setting position loop in the NC side is required.
(b) Variable speed control
(When using V-belt, or when spindle and motor are connected with a gear ratio other than 1:1)
Spindle control item
Control specifications
Without orientation option
Motor PLG
Motor PLG with Z-phase
Motor PLG with Z-phase
{
With orientation option
Magnetic sensor
{
Spindle side detector
(1020p/rev encoder)
{
Speed control
Orientation control
Normal cutting control
Constant surface speed control (lathe)
Thread cutting (lathe)
1-point orientation control
Multi-point orientation control
Orientation indexing
{
U
×
×
×
{
U
×
×
×
U
×
×
×
U
×
{
×
{
{
{
{
× × × × {
S-analog high-speed synchronous tap control
Standard synchronous tap
Synchronous tap after zero point return
(Note 1) { : Control possible
S
×
S
×
S
×
S
S
{
{
× : Control not possible
U : Control not possible when using V-belt
S : Control not possible when varying the speed with a method other than the gears and timing belt (when using V-belt or timing belt).
(Note 2) The S-analog high-speed synchronous tap control is an option deferent from orientation. For details, refer to “2-2-2 (2)
Spindle drive unit function specifications list”. Setting position loop in the NC side is required.
4 - 2
4. Dedicated Options
4-1-1 Magnetic sensor
Prepare the magnetic sensor parts with the following types. When purchasing independently, always prepare with the required configuration part types.
(1) Type
Tolerable
Type Type
Independent type speed [r/min] Drive unit Sensor Magnet
High-speed standard MAGSENSOR BKO-C1730H01.2.6
High-speed small MAGSENSOR BKO-C1730H01.2.9
0 to 12000
0 to 12000
MAGSENSOR BKO-C1730H01.2.41
0 to 25000
MAGSENSOR BKO-C1730H01.2.42
0 to 25000
High-speed ring
MAGSENSOR BKO-C1730H01.2.43
0 to 30000
MAGSENSOR BKO-C1730H01.2.44
0 to 30000
H01
H01
H01
H01
H01
H01
H01
H02
H02
H02
H02
H02
H02
H02
H03
H06
H09
H41
H42
H43
H44
(Note) When preparing with independent types, replace the section following the H in the prepared type with the independent type.
Example: When preparing only the standard magnetic sensor's sensor section, the type will be MAGSENSOR BKO-C1810H02.
(2) Outline dimension drawing: z Drive unit H01
2-ø5.5 hole 25
Connector (sensor side)
For BKO-C1810H01, R04-R08F is used.
For BKO-C1730H01, TRC116-21A10-7F is used.
Connector (controller cable side)
Unit side (TRC116-21A10-7M)
Cable side (TRC116-12A100-7F10.5)
[Unit: mm] z Sensor H02
Reference notch
32
14
1
25 5.5
Cable length 500
+100
-0
18
Connector
For BKO-C1810H02, R04-R-8M is used.
For BKO-C1730H02, TRC116-12A10-7M is used.
[Unit: mm]
CAUTION
When using the magnetic sensor, orientation control cannot be carried out with a machine having a gear ratio between the spindle motor and spindle exceeding
1:31.
4 - 3
z Magnet
Part
No.
Tolerable speed
H03
0 to 6000 r/min
H06
0 to 12000 r/min
4. Dedicated Options
Reference hole
Outline drawings
40
50
4-ø4.3 hole
2.5
7.5
Weight: 40 ± 1.5g
Installation screw: M4
H09
0 to 12000 r/min
H41
0 to 25000 r/min
S N
50
40
30
2-ø4.3 hole
Weight: 14.8 ± 0.7g
Installation screw: M4
N.P
Case E
D
Cover
Spun ring
RINGFEDER
RFN8006 J
×K
4-F screw
Stainless case
SUS-303
N
S
45°
H42
H43
H44
0 to 25000 r/min
0 to 30000 r/min
0 to 30000 r/min
Sensor head Stop position scale
2-øG
±0.15øH on circumference
Reference notch
∗ Polarity (N,S) is indicated on the side wall of cover.
Detection head should be installed so that the reference notch of sensor head comes on the case side.
[Unit: mm]
Magnet
Dimensions
Model A
BKO-C1730H41 105
BKO-C1730H42 94
BKO-C1730H43 78
BKO-C1730H44 66
Reference notch
Gap
G hole h6
B C D E
70H7 +0.030
–0
60H7 +0.030
–0
50H7 +0.025
–0
40H7 +0.025
–0
Spindle damping screw
Installation of magnet
Spindle
Case
Cover
F J
× X
L
79 25 17 M5
×0.8
5 79 60
×68 1
66 23 15 M5
×0.8
5 66 50
×57 1
54 20 13 M4
×0.7
5 54 40
×45 1
Weight
(g)
90 28 19 M6
×1.0
5 90 70
×79 1
1024
±4
768
±4
478
±4
322
±4
Cautions on installation of H41 to H44
1. Tolerance to shaft dimension should be "h6" on the part for installing a magnet.
2. 2-øG hole can be used for positioning of spindle and magnet.
3. Magnet shall be installed as shown to the left.
4. Misalignment between sensor head and magnetic center line shall be within
±2mm.
5. There is an NS indication on the side of the cover.
Install so that the reference notch on the sensor head comes to the case side.
4 - 4
4. Dedicated Options
(3) Caution on installation of magnet
Observe the following cautions when installing the magnet to the spindle.
(a) Do not place an intense magnetic source near the magnet.
(b) Carefully handle the magnet, avoiding mechanical shock to the magnet.
(c) Secure the magnet to the spindle with M4 screws.
(d) After the magnet is installed, balance the entire spindle.
(e) Align the center of the magnet with the center line of the rotating disk on the spindle. (For the position relation, refer to the maintenance instruction manual.)
(f) Keep the magnet and its peripheral clean avoiding iron particles and cutting chips from adhering to the magnet. Failure to observe this could result in malfunction.
(g) Apply lock paint, or other suitable means, to prevent installation screws from becoming loose.
(h) If the magnet is installed on a ground rotating disk, demagnetize the disk because the rotating disk is thought to be magnetized.
(i) Diameter of rotating disk on which the magnet is installed should be within the range from 80mm to 120mm. If this range is exceeded, the magnet may be damaged and the orient control may not be carried out correctly although the speed is below the tolerable speed of the magnet.
(j) If rotation speed of the spindle on which the magnet is installed exceeds 6,000r/min, use a high-speed type magnet (applicable up to 12,000r/min of rotation speed). If rotation speed exceeds 12,000r/min, use a ring type magnet.
(k) When installing the magnet on a rotating body plane, keep the speed below 6,000r/min.
(4) Caution on installation of sensor
Observe the following cautions when installing the sensor.
(a) The center line of head should be in line with the center of magnet.
(b) Connector used in preamplifier
BKO-C1810 : Oil proof-type
BKO-C1730 : Not oil proof-type
Install both type at a place not subject to oil.
(c) The cable between the preamplifier and the controller should be laid down apart from high-voltage cables.
(d) Check the connector wiring, securely engage the receptacle and tighten connector lock screws.
4 - 5
4. Dedicated Options
4-1-2 Spindle side detector (OSE-1024-3-15-68, OSE-1024-3-15-68-8)
When a spindle and motor are connected with a V-belt, or connected with a gear ratio other than 1:1, use this spindle side detector (1024p/rev encoder) to detect the position and speed of the spindle. Also use this detector when orientation control and synchronous tap control, etc are executed under the above conditions.
(2) Specifications
Detector type
Mechanical Inertia characteristics
Shaft friction torque for rotation
Shaft angle acceleration
Tolerable continuous rotation speed
Maximum rotation speed
Mechanical configuration
Bearing maximum non-lubrication time
Shaft amplitude
(position 15mm from end)
Tolerable load
(thrust direction/radial direction)
Weight
Squareness of flange to shaft
Flange matching eccentricity
Working environment
Ambient temperature range
Storage temperature range
Humidity
Vibration resistance
Impact resistance
OSE-1024-3-15-68 OSE-1024-3-15-68-8
0.1
× 10 -4 kgm
2
or less
0.98Nm or less
10
4
rad/s
2
or less
6000 r/min
7030 r/min
0.1
× 10 -4 kgm
2 or less
0.98Nm or less
10
4
rad/s
2 or less
8000 r/min
8030 r/min
20000h/6000r/min 20000h/8000r/min
0.02mm or less 0.02mm or less
10kg/20kg
Half of value during operation
10kg/20kg
Half of value during operation
1.5kg 1.5kg
0.05mm or less
0.05mm or less
–5°C to +55°C
–20°C to +85°C
95%Ph
5 to 50Hz, total vibration width 1.5mm, each shaft for 30min.
294.20m/s
2
(30G)
Signal name
A, B phase
Z phase
Number of detection pulses
1024p/rev
1p/rev
Connector pin layout
Pin Function
D
E
F
G
H
J
A
B
C
A phase
Z phase
B phase
-
Case earth
-
-
+5V
-
Pin Function
N
P
R
S
T
K
L
M
0V
-
-
A phase
Z phase
B phase
-
-
4 - 6
4. Dedicated Options
(3) Outline dimension drawings
102 33 68
MS3102A20-29P
3 2
4-
Ø
5.4 hole
2
5
+0.012
0
20
1.15
+0.14
0
Shaft section
Key way magnified figure
Spindle side detector (OSE-1024-3-15-68, OSE-1024-3-15-68-8)
[Unit: mm]
4 - 7
4. Dedicated Options
4-2 Cables and connectors
4-2-1 Cable connection diagram
The cable connected with CN4, CN5 or CN6 of spindle drive unit in the following diagram can be ordered from Mitsubishi Electric Corp. as option parts. Cables can only be ordered in the designated lengths. If a cable connected with the other connector or a cable with special length is required, purchase a connector or connector set, etc., and create the cable.
Spindle drive unit
(MDS-C1-SPA)
Power supply unit
(MDS-C1-CV)
NC
PC
DIO
Meter
Personal computer
CN5
CN4
CN6
(1)
(1)
(2) Spindle detector cable
Spindle side detector/magnetic sensor
<Spindle side detector (1024p/rev encoder)
/magnetic sensor cable>
Spindle motor
(2) Spindle detector cable
<Motor PLG / Spindle PLG cable>
4 - 8
4. Dedicated Options
4-2-2 List of cables and connectors
(1) NC bus cable and connector
(cable and connector between drive unit and power supply unit )
For
CN4
NC bus cable SH21
Length:
0.35, 0.5, 0.7, 1,
1.5, 2, 2.5, 3,
Drive unit side connector
(3M)
Connector : 10120-6000EL
Shell kit : 10320-3210-000
3.5,
6,
4, 4.5,
7, 8,
5,
9,
10, 15, 20, 30 m
FCUA-CS000 For
CN4
NC bus cable connector set
(Note) The connector manufacturer is subject to change without notice.
Drive unit side connector
(3M)
Connector : 10120-3000VE
Shell kit : 10320-52F0-008
Item Model Contents
Drive unit side connector
(3M)
Connector : 10120-6000EL
Shell kit : 10320-3210-000
Drive unit side connector
(3M)
Connector : 10120-3000VE
Shell kit : 10320-52F0-008
4 - 9
4. Dedicated Options
(2) Spindle detector cable
Item Model Contents
For CN5 Motor PLG cable
CNP5- -
Connector type
2: Connector
E: Crimped terminal
Axis No. (1 to 8 axis)
1: No. 1 axis to
8: No. 8 axis
Spindle drive unit side connector (3M)
Connector : 10120-3000VE
Shell kit : 10320-52F0-008
Spindle motor side connector
For 2-type
(Tyco Electronics AMP)
Plug : 350720-1
Pin : 350689-1
For E-type (J.S.T.)
Crimped terminal: V1.25-4
2-type
System No.
None : 1st system
2 : 2nd system
P : PLC axis
E-type
For CN6 Magnetic sensor cable
Length:
2, 5, 10, 20, 30 m
CNP6M-
-
Connector type
2: Connector
E: Crimped terminal
Spindle drive unit side connector (3M)
Connector : 10120-3000VE
Shell kit : 10320-52F0-008
Magnetic sensor side connector
For 2-type (Tajimi Musen)
Plug: TRC116-12A10-7F10.5
For E-type (J.S.T.)
Crimped terminal: V1.25-4
Axis No. (1 to 8 axis)
1: No. 1 axis to
8: No. 8 axis
2-type
System No.
None : 1st system
2 : 2nd system
P : PLC axis
E-type
Spindle side detector (1024p/rev encoder) cable
Length:
2, 5, 10, 20, 30 m
CNP6A - -
Connector type
2: Straight cannon
3: Angle cannon
E: Crimped terminal
Spindle drive unit side connector (3M)
Connector : 10120-3000VE
Shell kit : 10320-52F0-008
Axis No. (1 to 8 axis)
1: No. 1 axis to
8: No. 8 axis
Spindle side detector
(1024p/rev encoder) side connector
For 2-type (DDK)
Plug : MS3106A20-29S
Clamp : MS3057-12A
For 3-type (DDK)
Plug : MS3108A20-29S
Clamp : MS3057-12A
For E-type (J.S.T.)
Crimped terminal: V1.25-4
System No.
2 : 2nd system
P : PLC axis
Length:
2, 5, 10, 20, 30 m
(Note) The connector manufacturer is subject to change without notice.
2-type
3-type
E-type
4 - 10
4. Dedicated Options
(3) External connection cable
Cables shown below are made by the user.
Item Model Contents
For
CN10,
CN11,
CN12
DIO cable Spindle drive unit side connector (3M)
Connector : 10120-3000VE
Shell kit : 10320-52F0-008
External device
NC device
Programmable controller
External part DIO
Cable: Batch vinyl shield cable
0.2SQ x 20-core (Maximum diameter 12mm or less)
For
CN8A
Analog speed command input pulse feedback cable
For
CN9A
For meter output
Personal computer for parameter input
• monitor
Spindle drive unit side connector (3M)
Connector : 10120-3000VE
Shell kit : 10320-52F0-008
Cable: Twisted pair shield cable
0.3SQ x 4 + 0.3SQ x 3
External device
NC device
Programmable controller
Spindle drive unit side connector (3M)
Connector : 10120-3000VE
Shell kit : 10320-52F0-008
Cable: Twisted pair cable
0.3SQ x 2 + 0.3SQ x 2
External device
Speed meter
Load meter
Personal computer
(Note1) The connector manufacturer is subject to change without notice.
(Note2) Keep the length of the cables, excluding the cable for CN9A, which is connected with a personal computer, to 30m or less.
(The cable connected with a personal computer must be 3m or less.)
(Note3) Do not relay the CNP5, CNP6M or CNP6A cables. Malfunctions may occur due to noise from the motor drive wire or other cables. (Orientation position could dislocate, vibration could occur, etc.)
If the cable must be relayed, keep the peeled shield section as short as possible (3cm or less), and separate the cable from the other drive wires and cables. Mitsubishi will not be held liable for any problems that should occur as a result of a relayed cable. The customer is responsible for providing measures against noise.
4 - 11
5. Peripheral Devices
5-1 Selection of wire ................................................................................................................................. 5-2
5-1-1 Example of wires by unit ............................................................................................................. 5-2
5-2 Selection the AC reactor, contactor and no-fuse breaker.................................................................. 5-4
5-2-1 Standard selection....................................................................................................................... 5-4
5-2-2 Selection of contactor for changing over spindle motor drive wire ............................................. 5-5
5-3 Earth leakage breaker........................................................................................................................ 5-6
5-4 Branch-circuit protection .................................................................................................................... 5-7
5-4-1 Circuit protector ........................................................................................................................... 5-7
5-4-2 Fuse protection............................................................................................................................ 5-7
5-5 Noise filter .......................................................................................................................................... 5-8
5-6 Surge absorber .................................................................................................................................. 5-9
5-7 Speedometer and load meter........................................................................................................... 5-10
5-8 Cable for peripheral control.............................................................................................................. 5-11
5-8-1 Cable for external emergency stop ........................................................................................... 5-11
5 - 1
5. Peripheral Devices
5-1 Selection of wire
5-1-1 Example of wires by unit
Selected wires must be able to tolerate rated current of the unit’s terminal to which the wire is connected.
How to calculate tolerable current of an insulated wire or cable is shown in “Tolerable current of electric cable” (1) of Japanese Cable Makers’ Association Standard (JCS)-168-E (1995), its electric equipment technical standards or JEAC regulates tolerable current, etc. wire.
When exporting wires, select them according to the related standards of the country or area to export.
In the UL standards, certification conditions are to use wires of 60
o
C and 75
o
C product. (UL508C)
Wire’s tolerable current is different depending on conditions such as its material, structure, ambient temperature, etc. Check the tolerable current described in the specification of the wire to use.
Example of wire selections according to each standard is as follows.
(1) 600V vinyl insulated wire (IV wire) 60 o
C product
(Example according to IEC/EN60204-1, UL508C)
Unit type
Power supply unit
Spindle drive unit
Terminal
name
MDS-C1-CV-37
MDS-C1-CV-55
MDS-C1-CV-75
MDS-C1-CV-110
MDS-C1-CV-150
MDS-C1-CV-185
MDS-C1-CV-220
MDS-C1-CV-260
MDS-C1-CV-300
MDS-C1-CV-370
MDS-C1-SPA-55
MDS-C1-SPA-75
MDS-C1-SPA-110
MDS-C1-SPA-150
MDS-C1-SPA-185
MDS-C1-SPA-220
MDS-C1-SPA-260
MDS-C1-SPA-300
TE1 TE2 TE3
(L1, L2, L3, ) (L+, L-) (L11, L21, L12, L22, MC1) mm
2
AWG mm
2
AWG mm
2
AWG
3.5 12
3.5 12
5.5 10
14 6
22 4
30 3
38 2
Same as TE1
50 -
60 -
- -
3.5 12
5.5 10
8 8
14 6 selected power supply
22 4 unit
30 3
38 2
60 -
1.25 to 2
1.25 to 2
16 to 14
16 to 14
(2) 600V double (heat proof) vinyl insulated wire (HIV wire) 75
o
C product
(Example according to IEC/EN60204-1, UL508C)
Unit type
Power supply unit
Spindle drive unit
Terminal name
MDS-C1-CV-37
MDS-C1-CV-55
MDS-C1-CV-75
MDS-C1-CV-110
MDS-C1-CV-150
MDS-C1-CV-185
MDS-C1-CV-220
MDS-C1-CV-260
MDS-C1-CV-300
MDS-C1-CV-370
MDS-C1-SPA-55
MDS-C1-SPA-75
MDS-C1-SPA-110
MDS-C1-SPA-150
MDS-C1-SPA-185
MDS-C1-SPA-220
MDS-C1-SPA-260
MDS-C1-SPA-300
TE1 TE2 TE3
(L1, L2, L3, ) mm
2
AWG mm
2
(L+, L-) (L11, L21, L12, L22, MC1)
AWG mm
2
AWG
2 14
3.5 12
5.5 10
14 6
14 6
22 4
30 3
38 2
38 2
50 -
Same as TE1
2 14
3.5 12
5.5 10
14 6 selected power supply
14 6 unit
22 4
30 3
38 2
1.25 to 2
1.25 to 2
16 to 14
16 to 14
5 - 2
5. Peripheral Devices
(3) 600V bridge polyethylene insulated wire (IC) 105 o
C product
(Example according to JEAC8001)
Unit type
Power supply unit
Spindle drive unit
Terminal name
MDS-C1-CV-37
MDS-C1-CV-55
MDS-C1-CV-75
MDS-C1-CV-110
MDS-C1-CV-150
MDS-C1-CV-185
MDS-C1-CV-220
MDS-C1-CV-260
MDS-C1-CV-300
MDS-C1-CV-370
MDS-C1-SPA-55
MDS-C1-SPA-75
MDS-C1-SPA-110
MDS-C1-SPA-150
MDS-C1-SPA-185
MDS-C1-SPA-220
MDS-C1-SPA-260
MDS-C1-SPA-300
TE1 TE2 TE3
(L1, L2, L3, ) mm
2
AWG mm
(L+, L-) (L11, L21, L12, L22, MC1)
2
AWG mm
2
AWG
2 14 2 14
3.5 12 3.5 12
5.5 10 14 6
14 6 22 4
14 6 22 4
22 4 30 3
38 2 38 2
38 2 50 -
2 14
3.5 12
5.5 10
14 6 selected power supply
14 6 unit
22 4
1.25 to 2
30 3
38 2
16 to 14
16 to 14
CAUTION
1. Selection conditions follow IEC/EN60204-1, UL508C, JEAC8001.
• Ambient temperature is maximum 40°C.
• Cable installed on walls without ducts or conduits.
To use the wire under conditions other than above, check the standards you are supposed to follow.
2. The maximum wiring length to the motor is 30m.
If the wiring distance between the drive unit and motor is 20m or longer, use a thick wire so that the cable voltage drop is 2% or less.
3. Always wire the grounding wire.
5 - 3
5. Peripheral Devices
5-2 Selection the AC reactor, contactor and no-fuse breaker
5-2-1 Standard selection
Install an AC reactor, contactor and no-fuse breaker (NFB) per one power supply unit. Refer to the table below and select them according to each power supply unit capacity.
Selection of AC reactor, contactor and no-fuse breaker (NFB)
Power supply unit capacity
AC reactor
Recommended contactor
(Special order part)
Recommended main circuit NFB
(Special order part)
3.7 to 7.5kW
NF50CS3P-40A0
5
11kW 15 to 18.5kW 22 to 30kW 37kW
B-AL-7.5K B-AL-11K B-AL-18.5K B-AL-30K B-AL-37K
S-N25 200V S-N35 200V
NF50CS3P-50A05
S-N50 200V S-N80 200V S-N150 200V
NF100CS3P-100A05 NF225CS3P-150A05 NF225CS3P-175A05
Recommended motor fan NFB
(Special order part)
An NFB or CP (circuit protector) can be used as the motor fan breaker.
Select the NFB or CP using a value approximately double the motor fan rated current value shown below.
Contact the NFB or CP manufacturer for details on the recommended wire size, etc.
Spindle motor frame size
71 90 112 132 160 180
Motor fan rated current
0.1A 0.2A
0.2A
0.2A
0.6A
0.6A
* A rush current that is approximately double the above rated current flows when the motor starts.
(Note 1) In the above table, a special order part refers to a part that cannot be ordered from Mitsubishi, and which must be prepared by the user.
(Note 2) To comply with the EC Directives, use contactors and NFB that comply with the EN/IEC
Standards.
CAUTION
If a breaker is shared by several power supply units, the breaker may not activate when a short-circuit fault occurs in a small capacity unit. This is dangerous, so never share the breakers.
5 - 4
5. Peripheral Devices
5-2-2 Selection of contactor for changing over spindle motor drive wire
When using coil changeover motor and 1-drive unit 2-motor changeover function, select a contactor for changing over motor drive wire from the table below according to the capacity of spindle drive unit to be used.
Spindle drive unit type Recommended contactor type
MDS-A/B-SPA(H)-04
MDS-A/B-SPA(H)-075
MDS-A/B-SPA(H)-15
MDS-A/B-SPA(H)-22
MDS-A/B-SPA(H)-37
MDS-A/B/C1-SPA(H)-55
MDS-A/B/C1-SPA(H)-75
MDS-A/B/C1-SPA(H)-110
MDS-A/B/C1-SPA(H)-150
MDS-A/B/C1-SPA(H)-185
MDS-A/B/C1-SPA(H)-220
S-N10
S-N10
S-N10
S-N10
S-N18
S-N20
S-N25
S-N35
S-N50
S-N65
S-N80
MDS-A/B/C1-SPA(H)-260
MDS-A/B/C1-SPA(H)-300
S-N80
S-N125
MDS-B-SPA(H)-370
MDS-B-SPA(H)-450
S-N150
S-N180
MDS-B-SPA(H)-550 S-N300
(Note 1)
These contactors are prepared by the user.
(Note 2)
Use the EN/IEC Standards compliant parts in compliance with EC Directives.
5 - 5
5. Peripheral Devices
5-3 Earth leakage breaker
When installing an earth leakage breaker, select the breaker on the following basis to prevent the breaker from malfunctioning by the higher frequency earth leakage current generated in the spindle drive unit.
(1) Selection
Obtaining the earth leakage current for all drive units referring to the following table, select an earth leakage breaker within the “rated non-operation sensitivity current”.
Usually use an earth leakage breaker for inverter products that function at a leakage current within the commercial frequency range (50 to 60Hz).
If a product sensitive to higher frequencies is used, the breaker could malfunction at a level less than the maximum earth leakage current value.
Earth leakage current for each unit
Unit Earth leakage current Maximum earth leakage current
MDS-C1-SPA-55 to 300 6mA 15mA
(Note1) Maximum earth leakage current: Value that considers wiring length and grounding, etc.
(Commercial frequency 50/60Hz)
(Note2) The earth leakage current in the power supply unit side is included in the drive unit side.
(2) Measurement of earth leakage current
When actually measuring the earth leakage current, use a product that is not easily affected by the higher frequency earth leakage current. The measurement range should be 50 to 60Hz.
POINT
1. The earth leakage current tends to increase as the motor capacity increases.
2. A higher frequency earth leakage current will always be generated because the inverter circuit in the drive unit switches the transistor at high speed. Always ground to reduce the higher frequency earth leakage current as much as possible.
3. An earth leakage current containing higher frequency may reach approx. several hundreds of mA. According to IEC479-2, this level is not hazardous to the human body.
5 - 6
5. Peripheral Devices
5-4 Branch-circuit protection
5-4-1 Circuit protector
This breaker is used to switch the control power and to provide overload and short-circuit protection.
When connecting a circuit protector or breaker to the power input (TE3 terminals L11 and L21) for the control circuit, use a product that does not trip (incorrectly activate) by a rush current when the power is turned ON. A circuit protector with inertial delay and an operation delayed type breaker are available to prevent unnecessary tripping. Select the product to be used according to the machine specifications.
The rush current and rush conductivity time differ according to the power impedance and power ON timing, so select a product that does not trip even under the conditions listed in the following table.
Rush current: Ip=35
36.8%
I [A]
Time constant: T=6
Rush conductivity time:
Time to reach 36.8% of rush current; equivalent to breaker operation characteristics operation time. t [ms]
POINT
When collectively protecting the control circuit power for multiple units, select a circuit protector or breaker that satisfies the total sum of the rush current Ip.
The largest value is used for the rush conductivity time T.
5-4-2 Fuse protection
The fuse of branch-circuit protection must use UL class CC, J or T. In the selection, please consider rush current and rush conductive time.
Selection of branch-circuit protection fuse
Connected total of unit
Fuse (Class CC)
Rated [V] Current [A]
Wire Size
AWG
1 – 4
5 – 8
600
20
35
16 to 14
CAUTION
For continued protection against risk of fire, replace only with same type 600
V, 20 or 35 A (UL CLASS CC) fuse.
5 - 7
5. Peripheral Devices
5-5 Noise filter
(1) Selection
Use an EMC noise filter if the noise conducted to the power line must be reduced. Select an EMC noise filter taking the power supply unit's input rated voltage and input rated current into consideration.
(2) Noise filter mounting position
Install the noise filter to the power supply unit’s power input as the diagram below indicates.
Power distribution panel
Power supply unit
Breaker
AC reactor Contactor
Power supply
Noise filter
R
S
T
MDS-C1-CV
(Note) The noise filter must be prepared by the user.
Recommended devices: Okaya Electric Industries 3SUP-HL-ER-6B Series
Soshin Electric HF3000C-TMA Series
Contact: Okaya Electric Industries Co., Ltd. Telephone: 03-3424-8120
(+81-3-3424-8120) http://www.okayaelec.co.jp
Soshin Electric Co., Ltd. Telephone: 03-3775-9112
(+81-3-3775-9112) http://www.soshin.co.jp
(Note) The above devices may be changed at the manufacturer's discretion.
Contact each manufacturer for more information.
5 - 8
5. Peripheral Devices
5-6 Surge absorber
When controlling a magnetic brake of a servomotor in DC OFF circuit, a surge absorber must be installed to protect the relay contacts and brakes. Commonly a varistor is used.
(1) Selection of varistor
When a varistor is installed in parallel with the coil, the surge voltage can be adsorbed as heat to protect a circuit. Commonly a 120V product is applied. When the brake operation time is delayed, use a 220V product. Always confirm the operation with an actual machine.
(2) Specifications
Select a varistor with the following or equivalent specifications. To prevent short-circuiting, attach a flame resistant insulation tube, etc., onto the leads as shown in the following outline dimension drawing.
Varistor specifications
Varistor type
Varistor voltage rating
(range)
(V)
Tolerable circuit voltage
Rating
Surge current withstand level
Energy withstand level
(A)
AC (V) DC (V) 1 time 2 times 10/1000us
(J)
Power
Max. limit voltage
Electrostatic
2ms (W) (V) capacity
(reference value)
(pF)
ERZV10D121
TNR10V121K
ERZV10D221
TNR10V221K
POINT
120
(108 to 132)
220
(198 to 242)
75 100 3500 2500 20 14.5 0.4 200 1400
140 180 3500 2500 39 27.5 0.4 360
(Note 1) Selection condition: When ON/OFF frequency is 10 times/min or less, and exciting current is 2A or less
(Note 2) ERZV10D121 and ERZV10D221 are manufactured by Matsushita Electric Industrial Co., Ltd.
TNR10V121K and TNR10V221K are manufactured by MARCON Electronics Co., Ltd.
Contact: Matsushita Electronic Components Co., Ltd : http://www.panasonic.co.jp/ maco/
MARCON Electronics Co., Ltd. Telephone : (Kanto)03-3471-7041 (+81-3-3471-7041)
(Kinki) 06-6364-2381 (+81-3-6364-2381)
(Chubu) 052-581-2595 (+81-52-581-2595)
(3) Outline dimension drawing
• ERZV10D121, ERZV10D221
20.0
11.5
[Unit: mm]
Insulation tube
410
Normally use a product with 120V varistor voltage. If there is no allowance for the brake operation time, use the 220V product. A varistor whose voltage exceeds 220V cannot be used, as such varistor will exceed the specifications of the relay in the unit.
5 - 9
5. Peripheral Devices
5-7 Speedometer and load meter
Speedometer and load meter can be output from the D/A output which is for measuring control data.
When speedometer is output, +10V DC is output at the motor’s maximum speed regardless of the motor’s rotation direction. The following specifications are recommended for the display.
10 (a) Type YM-8G type DC voltage type (Mitsubishi)
(b) Rating 10VDC full scale
(c) Internal impedance approx. 10k
Ω
0
Maximum rotation speed
Motor rotation speed (r/min)
Speedometer output specification
(2) Load meter output
The load meter indicates the percentage of the load in respect to the motor's rated output. The relation of the motor output capacity [kW] and load meter display [%] is as follows.
0
Overload (for one minute) zone
50%ED (15-minute)
(30-minute) zone
Continuous rating zone
1500 6000
Motor rotation speed (r/min)
Load meter output specification
8000
Load meter 120%
Load meter 100%
The following specifications are recommended for the display.
(a) Type YM-8G type DC voltage type (Mitsubishi)
(b) Rating 10VDC full scale
(c) Internal impedance approx. 10k
Ω
(d) Scale indicating alarm at 100% or above (see right figure)
0
20
40
60
80
%
Load meter display
100
Red zone
120
5 - 10
5-8 Cable for peripheral control
5. Peripheral Devices
5-8-1 Cable for external emergency stop
Prepare the cable below for external emergency stop function (dual emergency stop function). The cable for external emergency stop must be prepared by the user.
External emergency stop connector
Bottom view of MDS-C1-CV
No. Item
101
102
Connector
Contact
101 102
Type
2-178288-3
1-175218-2
Manufacturer
Tyco Electronics AMP
Tyco Electronics AMP
Wire size:0.5 to 1.25SQ
Drive unit side
3
1
CN23
+
-
5 - 11
Appendix 1. Outline Dimension Drawings
Appendix 1-1 Outline dimension drawings of spindle motor ..................................................................A1-2
Appendix 1-1-1 SJ Series ...................................................................................................................A1-2
Appendix 1-1-2 SJ-V Series ...............................................................................................................A1-5
Appendix 1-1-3 SJ-VS Series ...........................................................................................................A1-15
Appendix 1-2 Unit outline dimension drawings ....................................................................................A1-17
Appendix 1-2-1 Spindle drive unit.....................................................................................................A1-17
Appendix 1-2-2 Power supply unit ....................................................................................................A1-21
Appendix 1-2-3 AC rector .................................................................................................................A1-25
A1 - 1
Appendix 1. Outline Dimension Drawings
Appendix 1-1 Outline dimension drawings of spindle motor
Appendix 1-1-1 SJ Series
• SJ-30A with standard flange
Terminal box 850
740
665.5
110
7 310
20
φ51
189
60 5
7
4-φ19
Exhaust air
Cooling fan
110
90
A
10.5
A
43
8
φ
30
0
φ
32
5
35°
Cooling air inlet
16
[Unit: mm]
A 55m6 A
Cross section
A-A
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
• SJ-30A with standard legs
Terminal box
850
505
430.5
345
230 110
90 10.5
6 312
189
6
Exhaust air
Cooling fan
127
304
127 108
A
A
Cooling air inlet
16
4-Ø15
55
127
310
127
A 55m6 A
Cross section
A-A
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) If the suspension bolts are removed during operation, plug the screw holes with bolts.
A1 - 2
[Unit: mm]
Appendix 1. Outline Dimension Drawings
• SJ-37BP, SJ-22XW5 with standard flange
Terminal box
909
769
701.5
530
φ51
68 5
140
25
7 350
224
Exhaust air
A
140
110 15
A
50
9
φ
35
0
φ
37
5
35°
Cooling air inlet
Cooling fan
18
7
4-φ19
A
60m6
Cross section
A-A
A
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
• SJ-37BP, SJ-22XW5 with standard legs
Terminal box
909
400.5
508.5
441
247.5
140 6 352
224
[Unit: mm]
6
Exhaust air
110
A
15
Cooling air inlet
A
Cooling fan
139.5
338
139.5
121 70
139.5
139.5
350
18
A 60m6 A
Cross section
A-A
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) If the suspension bolts are removed during operation, plug the screw holes with bolts.
A1 - 3
[Unit: mm]
Appendix 1. Outline Dimension Drawings
• SJ-45BP, SJ-22XW8 with standard flange
Terminal box
932
792
733
φ63
73
140
30
5
7 378
278
Exhaust air
140
110
A
15
A
Cooling fan
Cooling air inlet
7
4-φ19
58
1
φ
40
0
φ
42
5
35°
φ425
18
A 60m6
Cross section
A-A
A
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
• SJ-45BP, SJ-22XW8 with standard legs
Terminal box
932
272.5
425.5
140 6 506.5
447.5
φ63
380
278
[Unit: mm]
6
Exhaust air
Cooling fan
152.5
385
152.5
133
110
A
15
Cooling air inlet
A
4-φ19
85
159
400
18
159
A 60m6 A
Cross section
A-A
[Unit: mm]
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) If the suspension bolts are removed during operation, plug the screw holes with bolts.
A1 - 4
Appendix 1. Outline Dimension Drawings
Appendix 1-1-2 SJ-V Series
• SJ-V2.2-01, SJ-V3.7-02ZM with standard flange
φ35
Terminal box
360
300
265
60
130
48
12
5
Flange
□174
168
4-φ12
45
A
8
Exhaust air
A
φ
18
5
φ
19
0
Cooling fan
8
Cooling air inlet
5
2-M6 Screw
16
φ28j6
A
A
Cross section
A-A
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
• SJ-V2.2-01, SJ-V3.7-02ZM with standard legs
φ35
□176
φ
220
5
[Unit: mm]
Terminal box 300
360
265
130
60
5 176
168
5
45 8
Exhaust air
Cooling fan
75
105
56
41
A
A
Cooling air inlet
8
4-φ10 35
70
180
70
2-M6 Screw
16
φ28j6
A A
Cross section
A-A
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
A1 - 5
[Unit: mm]
Appendix 1. Outline Dimension Drawings
• SJ-V3.7-01 with standard flange
φ35
390
330
295
60
Terminal box
160
48
12
5
Flange
□174
168 4-φ12
Exhaust air
45
A
8
A
φ
18
5
φ
19
0
Cooling fan
5
φ22
0
Cooling air inlet
8
5 □176
16
2-M6
φ28j6
A A
Cross section
A-A
Screw
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
• SJ-V3.7-01 with standard legs
φ35
Terminal box
390
330
295
160
60
45 8
5 176
168
5
[Unit: mm]
Exhaust air
Cooling fan
A
Cooling air inlet
100
130
56
41
A
8
4-φ10 35
70
180
70
16
2-M6
φ28j6
A A
Cross section
A-A
Screw
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
A1 - 6
[Unit: mm]
Appendix 1. Outline Dimension Drawings
• SJ-V5.5-01 with standard flange
Terminal box
485
425
390
60
255
φ44
48
12
5
Flange
□174
168
4-φ12
Exhaust air
45
A
7.5
A
φ
18
5
φ1
90
φ
220
Cooling fan Cooling air inlet
7
5 □176
φ28h6
φ
22
3-M4 Screw
A A
Cross section
A-A
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
• SJ-V5.5-01 with standard legs
φ44
Terminal box
425
485
255
390
60
45 7.5
5 176
168
5
5
[Unit: mm]
Exhaust air
Cooling fan
159
190
56
41
A
A
Cooling air inlet
4-φ10
7
35
70
180
70
φ
22
φ28h6
A A
Cross section
A-A
3-M4 Screw
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
A1 - 7
[Unit: mm]
Appendix 1. Outline Dimension Drawings
• SJ-V7.5-01, SJ-V7.5-03ZM, SJ-V11-06ZM with standard flange
φ44
Terminal box
520
440
403
80
238
47 5
13
Flange
□204
198
4-φ15
Exhaust air
Cooling fan
63
A
8
A
φ
215
φ
22
5 φ25
0
Cooling air inlet
10
5 □208 5
φ
22
φ32h6
A A
Cross section
A-A
3-M5 Screw
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
• SJ-V7.5-01, SJ-V7.5-03ZM, SJ-V11-06ZM with standard legs
φ44
Terminal box
520
440
403
238
80
5 208
198
5
63 8
[Unit: mm]
A
Exhaust air
Cooling air inlet
A
Cooling fan
4-φ12
140
180
70
50
10
φ22
3-M5 Screw
φ32h6
A A
Cross section
A-A
45
95
230
95
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
A1 - 8
[Unit: mm]
Appendix 1. Outline Dimension Drawings
• SJ-V11-01, SJ-V11-08ZM with standard flange
φ44
Terminal box
490
453
600
288
110
65 5
13
Flange
□204
198
4-φ15
Exhaust air
80 10
A
A φ2
15
φ
22
5
Cooling fan
Cooling air inlet
14
5 □208
φ
40
φ48h6
A A
Cross section
A-A
3-M5 Screw
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
• SJ-V11-01, SJ-V11-08ZM with standard legs
φ44
Terminal box
490
453
600
110
288 5 208
198
80 10
5
φ25
0
5
[Unit: mm]
Exhaust air
Cooling fan
140
180
A
Cooling air inlet
A
70
50
14
4-φ12
45
95
230
95
φ4
0
3-M5 Screw
φ48h6
A A
Cross section
A-A
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
A1 - 9
[Unit: mm]
Appendix 1. Outline Dimension Drawings
• SJ-V15-01, SJ-V18.5-01, SJ-V11-09, SJ-V15-03, SJ-V22-06ZM with standard flange
φ44
Terminal box
579.5
469.5
434.5
259.5
65
110
20
5
266
□250
Flange
198
4-φ15
Exhaust air
80 10
A
A
φ
26
5
φ
27
5
φ30
0
Cooling fan
Cooling air inlet
14
5 □262 5
φ
40
3-M5 Screw
φ48h6
A A
Cross section
A-A
[Unit: mm]
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
• SJ-V15-01, SJ-V18.5-01, SJ-V11-09, SJ-V15-03, SJ-V22-06ZM with standard legs
φ44
Terminal box
579.5
469.5
434.5
259.5
110
80 10
5 262
198
5
Exhaust air
Cooling fan
A
A
Cooling air inlet
178
250
108
60
14
4-φ15
50
127
295
127
φ
40
3-M5 Screw
φ48h6
A A
Cross section
A-A
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
[Unit: mm]
A1 - 10
Appendix 1. Outline Dimension Drawings
• SJ-V30-02ZM with standard flange
φ51
Terminal box
649.5
539.5
499.5
329.5
110
20
266
□250 Flange
238
65 5
4-φ15
Exhaust air
80
A
10
A φ
26
5 φ
27
5
φ30
0
Cooling fan
Cooling air inlet
5 □262 5
14
φ
40
φ48h6
A A
Cross section
A-A
3-M5 Screw
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
• SJ-V30-02ZM with standard legs
φ51
Terminal box
649.5
539.5
499.5
329.5
110
80 10
5 262
238
5
[Unit: mm]
Exhaust air
Cooling fan
178
250
A
A
Cooling air inlet
108
60
14
4-φ15
50
127
295
127
φ
40
φ48h6
A A
Cross section
A-A
3-M5 Screw
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
A1 - 11
[Unit: mm]
Appendix 1. Outline Dimension Drawings
• SJ-V22-01, SJ-V18.5-03, SJ-V22-05 with standard flange
Terminal box
φ51
649.5
539.5
499.5
110
329.5
20
266
□250 Flange
238
65 5
4-φ15
Exhaust air
90
A
10.5
A φ
26
5 φ
27
5
φ30
0
Cooling fan
Cooling air inlet
5 □262 5
16
φ4
5
φ55m6
A A
Cross section
A-A
3-M5 Screw
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
• SJ-V22-01, SJ-V18.5-03, SJ-V22-05 with standard legs
φ51
Terminal box
649.5
539.5
499.5
329.5
110
90 10.5
5 262
238
5
[Unit: mm]
Exhaust air
Cooling fan
178
275
A
A
Cooling air inlet
108
60
4-φ15
16
50
127
295
127
φ
45
φ55m6
A A
Cross section
A-A
3-M5 Screw
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
[Unit: mm]
A1 - 12
Appendix 1. Outline Dimension Drawings
• SJ-V26-01 with standard flange
φ51
Terminal box
695.5
585.5
545.5
375.5
110
20
Flange
□250
238
65 5
4-φ15
Exhaust air
90
A
10.5
A φ
26
5
φ
27
5
φ30
0
Cooling fan
Cooling air inlet
16
5 □262
φ
45
φ55m6
A A
Cross section
A-A
3-M5 Screw
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
• SJ-V26-01 with standard legs
φ51
Terminal box
695.5
585.5
545.5
110
375.5
5 262
238
5
90 10.5
5
[Unit: mm]
Exhaust air
Cooling fan
178
275
A
A
Cooling air inlet
108
60
4-φ15
16
50
127
295
127
φ
45
φ55m6
A A
Cross section
A-A
3-M5 Screw
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
[Unit: mm]
A1 - 13
Appendix 1. Outline Dimension Drawings
• SJ-V55-01 with standard flange
φ63
Terminal box
864
724
672
402
140
75
30
5
□480
348 4-φ24
110
A
15
Exhaust air
Cooling fan
A
Cooling air inlet
20
φ5
00
φ
51
0 φ550
35°
2-M10
φ
65
φ75m6
A A
Cross section
A-A
3-M6 Screw
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
• SJ-V55-01 with standard legs
φ63
Terminal box 864
724
672
140
402
110 15
6 426
348
6
[Unit: mm]
A
Exhaust air
Cooling air inlet
A
Cooling fan
286
366
149
109
4-φ19
20
80
178
435
178
φ
65
φ75m6
A A
Cross section
A-A
3-M6 Screw
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
[Unit: mm]
A1 - 14
Appendix 1. Outline Dimension Drawings
Appendix 1-1-3 SJ-VS Series
• SJ-VS7.5-03ZM with standard flange
φ44
Terminal box
32
210
453
405.5
230.5
47
80
5
13
□204
198
4-φ15
B
Cooling fan Exhaust air
504
Cooling air inlet
340
A
5
φ
21
5
φ
27
5
160
□208
35°
5
φ
250
B
A
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
• SJ-VS22-06ZM with standard flange
φ44
[Unit: mm]
Terminal box
32
210
479
411.5
241.5
65
110
5
20
□250
238
4-φ15
B
Cooling fan Exhaust air
545
Cooling air inlet
351
A
5
φ
26
5 φ
27
5
190
□262
35°
5
φ
300
B
A
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
[Unit: mm]
A1 - 15
Appendix 1. Outline Dimension Drawings
• SJ-VS30-02ZM with standard flange
φ51
Terminal box
32
210
549
481.5
311.5
65
110
5
20
□250
238
4-φ15
B
Cooling fan Exhaust air
615
Cooling air inlet
421
A
5
φ
26
5
φ
27
5
35°
190
□ 262 5
φ
300
B
A
(Note 1) Provide a clearance of 30mm or more between the cooling fan and wall.
(Note 2) The shaft can also be mounted upward.
(Note 3) If the suspension bolts are removed during operation, plug the screw holes with bolts.
[Unit: mm]
A1 - 16
Appendix 1. Outline Dimension Drawings
Appendix 1-2 Unit outline dimension drawings
Appendix 1-2-1 Spindle drive unit
MDS-C1-SPA-55
MDS-C1-SPA-75
MDS-C1-SPA-110
φ6hole
70
(Wiring allowance
Intake
22
2-M6 screw
2-M4 screw
16
6
45
90
(State with terminal block cover removed)
Terminal block cover
20
Intake
180
260
60 15
Required wind passage space
3-M5 screw
2-M5 screw
Square hole
(Note 1)
2-M5 screw hole 82
Panel mounting hole machining drawing
(Note 1) Attach packing around the square hole for sealing.
[Unit : mm]
A1 - 17
Appendix 1. Outline Dimension Drawings
MDS-C1-SPA-150
MDS-C1-SPA-185
φ6hole
70
(Wiring allowance)
Intake
22
2-M6 screw
2-M4 screw
16
6
60
120
Terminal block cover
(State with terminal block cover removed)
20
Intake
180
260
60 15
Required wind passage space
3-M5 screw
Square hole
(Note 1)
2-M5 screw
2-M5 screw hole
112
Panel mounting hole machining drawing
(Note 1) Attach packing around the square hole for sealing.
[Unit : mm]
A1 - 18
Appendix 1. Outline Dimension Drawings
MDS-C1-SPA-220
2-φ6 hole
70
(Wiring allowance)
Intake
52
2-M6 screw
2-M4 screw 46
6 6
45 60
150
(State with terminal block cover removed)
Terminal block cover
60
20
• For MDS-C1-SP
3-M8 screw
Square hole
(Note 1)
Intake
180 60
260
15
Required wind passage space
2-M8 screw
4-M5 screw hole 142
Panel mounting hole
machining drawing
(Note 1) Attach packing around the square hole for sealing.
A1 - 19
[Unit : mm]
Appendix 1. Outline Dimension Drawings
MDS-C1-SPA-260
MDS-C1-SPA-300
2-φ6 hole
70
(Wiring allowance)
Exhaust
52
2-M6 screw
2-M4 screw 46
6 6
45 60
150
(State with terminal block cover removed)
Terminal block cover
60
20
Intake
180 63
263
12
Heat dissipation allowance
3-M8 screw
Square hole
(Note 1)
2-M8 screw
4-M5 screw hole 142
Panel mounting hole
machining drawing
(Note 1) Attach packing around the square hole for sealing.
A1 - 20
[Unit : mm]
Appendix 1. Outline Dimension Drawings
Appendix 1-2-2 Power supply unit
ø6 hole
MDS-C1-CV-37
MDS-C1-CV-55
MDS-C1-CV-75
70
(Wiring allowance)
22
2-M6 screw
3-M4 screw
16
30
60
6
(State with terminal block
cover removed)
Terminal block cover
20 180
220
Intake
(Note 2)
20 15
Heat dissipation allowance
3-M4 screw
2-M4 screw
Square hole
(Note 1)
2-M5 screw hole 52
Panel mounting hole machining drawing
(Note 1) Attach packing around the square hole for sealing
(Note 2) The MDS-C1-CV-37 does not have a built-in fan.
A1 - 21
[Unit : mm]
ø6 hole
MDS-C1-CV-110
Appendix 1. Outline Dimension Drawings
70
(Wiring allowance)
(Note 2)
22
2-M6 screw
3-M4 screw
16
45
90
6
(State with terminal block
cover removed)
Terminal block cover
20
Intake
180
260
60 15
Required wind passage space
3-M5 screw
2-M5 screw
Square hole
(Note 1)
2-M5 screw hole 82
Panel mounting hole machining drawing
(Note 1) Attach packing around the square hole for sealing
(Note 2) The MDS-C1-CV-110 does not have a fan at the top.
A1 - 22
[Unit : mm]
Appendix 1. Outline Dimension Drawings
ø6 hole
MDS-C1-CV-150
MDS-C1-CV-185
70
(Wiring allowance)
(Note 2)
22
2-M6 screw
3-M4 screw
16
60
120
6
(State with terminal block
cover removed)
Terminal block cover
20
Intake
180
260
60 15
Required wind passage space
3-M5 screw
2-M5 screw
Square hole
(Note 1)
2-M5 screw hole 112
Panel mounting hole machining drawing
(Note 1) Attach packing around the square hole for sealing.
(Note 2) The MDS-C1-CV-150/185 does not have a fan at the top.
A1 - 23
[Unit : mm]
MDS-C1-CV-220
MDS-C1-CV-260
MDS-C1-CV-300
MDS-C1-CV-370
2-ø6 hole
Appendix 1. Outline Dimension Drawings
70
(Wiring allowance)
Intake
42
2-M6 screw
3-M4 screw
45
6
60
150
6 36
60
(State with terminal block
cover removed)
Terminal block cover
20
Intake
180
260
60 15
Required wind passage space
3-M8 screw
Square hole
(Note 1)
2-M8 screw
4-M5 screw hole 142
Panel mounting hole machining drawing (Note 1) Attach packing around the square hole for sealing.
A1 - 24
[Unit : mm]
Appendix 1-2-3 AC rector
• B-AL-7.5K
Appendix 1. Outline Dimension Drawings
6-M5 screw
FG grounding position
L11
L12
MAIN
DRIVE
L21
L22
L31
L32
PE grounding position
(with grounding mark)
Terminal cover
55
± 1
4-8×15 slot
165
± 2
• B-AL-11K
6-M5 screw
FG grounding position
L11
L12
MAIN
DRIVE
L21
L22
L31
L32
PE grounding position
(with grounding mark)
Terminal cover
55
± 1
4-8×15 slot
[Unit: mm]
165
± 2
A1 - 25
[Unit: mm]
• B-AL-18.5K
Appendix 1. Outline Dimension Drawings
6-M6 screw
FG grounding position
MAIN
L11
L12
DRIVE
L21
L22
L31
L32
PE grounding position
(with grounding mark)
Terminal cover
55
± 1
4-8×15 slot
165
± 2
• B-AL-30K
6-M6 screw
FG grounding position
L11
L12
MAIN
DRIVE
L21
L22
L31
L32
PE grounding position
(with grounding mark)
Terminal cover
55
± 1
4-8×15 slot
[Unit: mm]
165
± 2
A1 - 26
[Unit: mm]
• B-AL-37K
Appendix 1. Outline Dimension Drawings
6-M6 screw
FG grounding position
MAIN
L11
L12
DRIVE
L21
L22
L31
L32
PE grounding position
(with grounding mark)
Terminal cover
70
± 1
4-8×15 slot
220
± 2
[Unit: mm]
A1 - 27
Appendix 2. Cable and Connector Specifications
Appendix 2-1 Selection of cable.............................................................................................................A2-2
Appendix 2-1-1 Cable wire and assembly ..........................................................................................A2-2
Appendix 2-2 Cable connection diagram ...............................................................................................A2-4
Appendix 2-3 Connector outline dimension drawings............................................................................A2-8
A2 - 1
Appendix 2. Cable and Connector Specifications
Appendix 2-1 Selection of cable
Appendix 2-1-1 Cable wire and assembly
The following shows the specifications and processing of the wire used in each cable. Manufacture the cable using the following recommended wire or equivalent parts.
Recommended wire model
(Cannot be directly ordered from
Mitsubishi
Finished outside diameter
Sheath material
No. of pairs
Electric Corp.)
Wire characteristics
Configuration
Conductor resistance
Withstand voltage
Insulation resistance
Heat resistant temperature
UL20276 AWG28
10pair
6.1mm PVC 10
7 strands/
0.13mm
222
Ω/km or less
AC350/ 1min
1M
Ω/km or more
80°C
Applica- tion
NC unit communi- cation cable
A14B2343 (Note 1) 7.2mm PVC 6
40 strands/
0.08mm
TS-91026 (Note 2) 11.6mm PVC
2
(0.3 mm
2
)
10
(0.2 mm
2
)
60 strands/
0.08mm
40 strands/
0.08mm
(Note 1) Junko Co. (Dealer: Toa Denki)
(Note 2) BANDO ELECTRIC WIRE (http: //www.bew.co.jp)
105
Ω/km or less
63 or less
95
Ω/km
Ω/km or less
AC500/ 1min
1500M
Ω/k m or more
AC750V/
1min
60M
Ω/km or more
105°C
60°C
Detector cable
Detector cable
(Cable length:
20m or more)
(2) Cable assembly
Assemble the cable as shown in the following drawing, with the cable shield wire securely connected to the ground plate of the connector.
Core wire Core wire
Shield (external conductor)
Sheath
Shield
(external conductor)
Sheath
Ground plate
A2 - 2
Appendix 2. Cable and Connector Specifications
(3) Cable protection tube (noise countermeasure)
If influence from noise is unavoidable, or further noise resistance is required, selecting a flexible tube and running the signal cable through this tube is effective. This is also an effective countermeasure for preventing the cable sheath from being cut or becoming worn.
A cable clamp (MS3057) is not installed on the detector side, so be particularly careful of broken wires in applications involving bending and vibration.
Supplier Tube
Drive unit side
Connector
Installation screws
Nippon Flex
Control Corp.
DAIWA DENGYO
CO., LTD
FBA-4
(FePb wire braid sheath)
Hi-flex
PT #17 (FePb sheath)
RBC-104 (straight)
RBC-204 (45
°)
RBC-304 (90
°)
PSG-104 (straight)
PLG-17 (90
°)
PS-17 (straight)
G16
G16
G16
Screw diameter ø26.4
Screw diameter ø26.4
PF1/2
Sankei Works
Purika Tube
PA-2 #17 (FePb sheath)
BC-17 (straight) Wire tube screws : 15
(Note) None of the parts in this table can be ordered from Mitsubishi Electric Corp.
Motor detector side
RCC-104-CA2022
PDC20-17
PDC20-17
A2 - 3
Appendix 2. Cable and Connector Specifications
Appendix 2-2 Cable connection diagram
CAUTION
1. Do not mistake the connection when manufacturing the detector cable.
Failure to observe this could lead to faults, runaway or fires.
2. Do not connect anything to pins unless otherwise particularly specified when manufacturing a cable. (Leave OPEN)
3. Contact Mitsubishi when manufacturing a cable longer than 30m.
4. Do not relay the cable which the shield cable is used in. Malfunctions may occur due to noise from the motor drive wire, other cables or devices.
If the cable must be relayed, keep the peeled shield section as short as possible (3cm or less), and separate the cable from the other drive wires and cables. Mitsubishi will not be held liable for any problems that should occur as a result of a relayed cable. The customer is responsible for providing measures against noise.
(1) NC bus cable (Cable between spindle drive unit and power supply unit)
<SH21 cable connection diagram>
Drive unit side connector
Connector: 10120-3000VE
Shell kit: 10320-52F0-008
19
10
20
PE
16
7
17
8
18
9
13
4
14
5
15
6
1
11
2
12
3
1
11
2
12
3
17
8
18
9
19
10
20
15
6
16
7
13
4
14
5
Drive unit side connector
Connector: 10120-3000VE
Shell kit: 10320-52F0-008
PE FG
A2 - 4
Appendix 2. Cable and Connector Specifications
(2) Spindle detector cable
<CNP5 cable connection diagram>
(CN5) Spindle drive unit side connector
Connector: 10120-3000VE
Shell kit: 10320-52F0-008
PA
RA
PB
RB
PZ
P15(+15V)
N15(-15V)
LG
6
16
7
17
8
5
15
1
Motor PLG side connector
Housing: 350720-1
Pin: 350689-1
1
2
3
4
5
8
6
9
MOH
RG
3
13
V1.25-4
100mm
<CNP6M cable connection diagram>
(CN6) Spindle drive unit side connector
Connector: 10120-3000VE
Shell kit: 10320-52F0-008
MAG 6
MAGR
LS
LSR
P15(+15V)
LG
16
7
17
5
15
Magnetic sensor side connector
Connector: TRC116-12A10-7F10.5
A
D
F
E
C
B
<CNP6A cable connection diagram>
(CN6) Spindle drive unit side connector
Connector: 10120-3000VE
Shell kit: 10320-52F0-008
MA
MA
*
MB
MB
*
MZ
MZ
*
P5(+5V)
LG
P5(+5V)
LG
P5(+5V)
LG
4
14
10
1
2
12
3
13
19
11
20
15
B
P
H
K
A
N
C
R
Spindle side detector (1024p/rev encoder) side connector
Plug: MS3106B20-29S (Straight)
MS3108B20-29S (Angle)
Clamp: MS3057-12A
CAUTION
The shield of the spindle detector cable is not connected to the "FG" (earth). Do not connect the cable shield to the earth by clamping the cable, etc.
A2 - 5
Appendix 2. Cable and Connector Specifications
<CN8A cable connection diagram>
(CN8A) Spindle drive unit side connector
Connector: 10120-3000VE
Shell kit: 10320-52F0-008
OR3
RP
SE1
SE2
SES
OR2
OR1
ORS
SYA
SYA
SYB
SYB
*
SYZ
SYZ
GND
GND
*
*
13
4
14
1
11
15
2
12
3
16
6
7
8
5
17
18
NC,PC side
SYZ
SYZ
*
GND
GND
FG
OR3
RP
SE1
SE2
OR2
OR1
SYA
SYA
*
SYB
SYB
*
<CN9A cable connection diagram>
(CN9A) Spindle drive unit side connector
Connector: 10120-3000VE
Shell kit: 10320-52F0-008
TX
RX
GND
SM0
LM0
OM
OUT8
15
5
11
9
19
1
8
<CN10 cable connection diagram>
(CN10) Spindle drive unit side
Connector:
Shell kit: connector
10120-3000VE
10320-52F0-008
16
8
18
9
14
5
15
6
19
20
17
10
1
11
2
12
3
13
4
REDY
SRN
SRI
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
IN11
IN12
CES1
OUT6C
+24V
RG
NC,PC side
Personal computer side
TX
RX
GND
SM0
LM0
0M
OUT8
NC、PC side
DIO devices side
REDY
SRN
SRI
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
IN11
IN12
CES1
OUT6C
+24V
RG
A2 - 6
Appendix 2. Cable and Connector Specifications
<CN11 cable connection diagram>
(CN11) Spindle drive unit side
connector
Connector:
10120-3000VE
Shell kit: 10320-52F0-008
16
19
7
17
14
5
15
6
8
18
9
10
20
12
3
13
4
1
11
2
8H
9H
10H
11H
12H
CES3
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
1H
2H
3H
4H
5H
6H
7H
<CN12 cable connection diagram>
(CN12) Spindle drive unit side
connector
Connector: 10120-3000VE
Shell kit: 10320-52F0-008
19
7
17
8
5
15
6
16
18
9
10
20
3
13
4
14
1
11
2
12
R9
R10
R11
R12
CES2
OUT1C
OUT2C
OUT3C
OUT4C
OUT5C
FA
FC
R5
R6
R7
R8
R1
R2
R3
R4
NC、PC side
DIO devises side
1H
2H
3H
4H
5H
6H
7H
8H
9H
10H
11H
12H
CES3
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
NC、PC side
DIO devises side
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
R12
CES2
OUT1C
OUT2C
OUT3C
OUT4C
OUT5C
FA
FC
A2 - 7
Appendix 2. Cable and Connector Specifications
Appendix 2-3 Connector outline dimension drawings
Connector for CN2 Servo drive unit
Manufacturer: 3M (Ltd.)
<Type>
Connector: 10120-3000VE
Shell kit: 10320-52F0-008
[Unit: mm]
12.0
22.0
14.0
Manufacturer: 3M (Ltd.)
<Type>
Connector: 10120-3000VE
Shell kit: 10320-52A0-008
[Unit: mm]
33.3
12.7
12.0
22.0
14.0
Manufacturer: 3M (Ltd.)
<Type>
Connector: 10120-6000EL
Shell kit: 10320-3210-000
Because this connector is an integrated molding part of the cable, it is not an option setting in the connector set.
The terminal connector
(A-TM) also has the same outline.
[Unit: mm]
A2 - 8
33.3
12.7
20.9
29.7
Appendix 3. Selection
Appendix 3-1 Selecting the power supply ..............................................................................................A3-2
Appendix 3-1-1 Selecting according to the continuous rated capacity...............................................A3-2
Appendix 3-1-2 Selection example .....................................................................................................A3-3
A3 - 1
Appendix 3. Selection
Appendix 3-1 Selecting the power supply
When selecting the power supply capacity, select the capacity that satisfies both the "Appendix 3-1-1
Selecting according to the continuous rated capacity".
Appendix 3-1-1 Selecting according to the continuous rated capacity
Select the power supply capacity that satisfies the following conditions for the spindle motor to which the power is supplied.
Power supply unit rated capacity
≥ ∑ (spindle motor output)….. (1)
Rated capacity of power supply unit
150 185 220 MDS-C1-CV- 37 55 75 110
Rated capacity:
(kW)
4.2 6.0 8.0 11.5
15.5
19.0
23.0
POINT
1. "Spindle motor output" refers to the short time rated output (kW) of the spindle motor.
2. If the spindle motor output in acceleration/deceleration is different from that in steady state, substitute the larger value for "spindle motor output".
3. If the spindle motor output is limited, multiply the output value by the limit rate and then substitute the multiplied value for "spindle motor output".
4. If a spindle motor has a coil switch function, calculate with the specification of the coil that has larger output.
CAUTION
1. If the selection capacity exceeds 38.0kW, use two or more power supply units. Select so that the capacity of each power supply unit satisfies the expressions (1).
2. Only when MDS-B-SPA-370 or larger capacity spindle drive unit is connected, a large-capacity power supply unit (MDS-B-CVE-450, 550) can be used. Refer to "Appendix 4. Explanation of Large Capacity Spindle Unit
Specifications" for details.
3. For the spindle drive unit, the drive unit capacity may become large depending on the spindle motor such as high-troupe motor. Make sure that the capacity limit of drive unit which can be connected is provided depending on the power supply.
Power supply unit Spindle drive unit
MDS-C1-CV- 37
55
75
110
150
185
220
260
300
370
MDS-C1-SPA-55 to 75
MDS-C1-SPA-55 to 110
MDS-C1-SPA-55 to 150
MDS-C1-SPA-55 to 185
MDS-C1-SPA-55 to 220
MDS-C1-SPA-55 to 260
MDS-C1-SPA-55 to 300
MDS-C1-SPA-55 to 300
MDS-B-SP-370
MDS-C1-SPA-55 to 300
MDS-B-SP-370 to 450
MDS-C1-SPA-55 to 300
MDS-B-SP-370 to 550
A3 - 2
Appendix 3. Selection
Appendix 3-1-2 Selection example
(Example 1) Spindle motor : SJ-V18.5-03 30-minute rated output 11kW
Spindle drive unit: MDS-C1-SPA-220
(1) Selection with rated capacity
Σ(Spindle motor output) = 11kW
→ "MDS-C1-CV-110" that has the selection capacity of 11kW, or larger unit is required.
(2) Selection with spindle drive unit
According to the table in the previous section , "MDS-C1-CV-150" or larger unit is required for the power supply unit which can be combined with
"MDS-C1-SPA-220".
(3) Overall selection
Select the power supply unit "MDS-C1-CV-150" that meets the conditions (1) and (2).
(Example 2) Spindle motor: No.1 SJ-V5.5-01 30-minute rated output 5.5kW
No.2 SJ-V18.5-03 30-minute rated output 11kW
Spindle drive unit: No.1 MDS-C1-SPA-55
No.2 MDS-C1-SPA-220
(1) Selection with rated capacity
Σ(Spindle motor output) = 5.5kW + 11kW = 16.5kW
→"MDS-C1-CV-185" that has the selection capacity of 16.5kW, or larger unit is required.
(2) Selection with spindle drive unit
No.1 According to the table in the previous section, "MDS-C1-CV-37" or larger unit is required for the power supply unit which can be combined with "MDS-C1-SPA-75".
No.2 According to the table in the previous section, "MDS-C1-CV-150" or larger unit is required for the power supply unit which can be combined with "MDS-C1-SPA-75".
(3) Overall selection
Select the power supply unit " MDS-C1-CV-185" that meets the conditions (1) and (2).
A3 - 3
Appendix 4. Explanation of Large Capacity Spindle
Unit Specifications
Appendix 4-1 Explanation of large capacity spindle unit specifications .................................................A4-2
Appendix 4-1-1 Outline .......................................................................................................................A4-2
Appendix 4-1-2 List of units ................................................................................................................A4-2
Appendix 4-1-3 Selection of AC reactor (B-AL), contactor and NFB .................................................A4-2
Appendix 4-1-4 Outline dimension drawings ......................................................................................A4-3
Appendix 4-1-5 Panel cut dimension drawing ....................................................................................A4-8
Appendix 4-1-6 Heating value ............................................................................................................A4-9
Appendix 4-1-7 Selecting the power capacity ....................................................................................A4-9
Appendix 4-1-8 Selecting the wire size ..............................................................................................A4-9
Appendix 4-1-9 Drive unit connection screw size.............................................................................A4-10
Appendix 4-1-10 Connecting each unit ............................................................................................A4-10
Appendix 4-1-11 Restrictions............................................................................................................A4-12
Appendix 4-1-12 Parameters............................................................................................................A4-14
Appendix 4-1-13 Precautions ...........................................................................................................A4-14
A4 - 1
Appendix 4. Explanation of Large Capacity Spindle Unit Specifications
Appendix 4-1 Explanation of large capacity spindle unit specifications
Appendix 4-1-1 Outline
The MDS-B-SPA Series large capacity spindle unit (37KW, 45KW, 55KW) is an expanded capacity version of the MDS-C1-SPA Series standard spindle unit (30KW or less).
Additional items related to the increased capacity are explained in this section.
Appendix 4-1-2 List of units
<Power supply unit> <Spindle drive unit>
Type
Capacity
(kW)
Weight
(kg)
B-CVE-450
B-CVE-550
45 20 B-SPA-370
55 21 B-SPA-450
37 20
45 21
B-SPA-550 55 21
(Note) Use the MDS-C1-CV-370 for the power supply unit 37kW.
Appendix 4-1-3 Selection of AC reactor (B-AL), contactor and NFB
Always mount the AC reactor and contactor shown below on the input side of each power supply unit
(B-CVE-450, 550).
(Note 1) Always mount one contactor for each power supply unit when using the MDS-B-CVE-450 or
550. The power supply unit could be damaged if the contactor is omitted or shared with another unit.)
(Note 2) Always mount one AC reactor for each power supply unit. The power supply unit could be damaged if the AC reactor is omitted or shared.
The selection of the NFB when using only one power supply unit is shown below for reference.
Capacity
Type
(kW)
Weight
(kg)
Power supply unit type
AC reactor (ordered part)
Recommended contactor
(special order part)
Recommended NFB
(special order part)
MDS-B-CVE-450 MDS-B-CVE-550
B-AL-45K B-AL-55K
S-N150 S-N180
NF225CS3P-200A NF400CS3P-300A
(Note) Even when OFF, an earth leakage current of maximum 15mA flows at the coil connection terminal MC1 for the power supply unit's external contactor. Thus, when using a contactor other than that recommended above, do not use the contactor that can be turned ON at 15mA or less or cannot be turned OFF at 15mA. When using a contactor with an internal electronic circuit, consult with the contactor manufacturer and make sure that the contactor will operate correctly even if an earth leakage current of 15mA or less flows.
A4 - 2
Appendix 4. Explanation of Large Capacity Spindle Unit Specifications
Appendix 4-1-4 Outline dimension drawings
The I bolt mounting hole is provided only at the top of the MDS-B-CVE-550 and MDS-B-SPA-450, 550.
The I bolt (size: M10) is not enclosed and must be prepared by the user. Use an I bolt with a 13 to 25mm long thread.
(1) MDS-B-CVE-450
180
AIR FLOW
Fin
L+
L–
L+
L–
L11 L12
MC1
L21 L22
MC2
L1 L2 L3
60
4-ø6 hole
120
240
60 63 146 114
(Note) Always install a large capacity drive unit in the left side of power supply unit, and connect TE2(L+,L-) with DC connection bar.
[Unit : mm]
A4 - 3
Appendix 4. Explanation of Large Capacity Spindle Unit Specifications
(2) MDS-B-CVE-550
2-M10 screw for I-bolt mounting
Only on top
180
AIR
FLOW
Fin
L+
L–
L+
L–
L11 L12
MC1
L21 L22
MC2
L1 L2 L3
60
4-ø6 hole
180
300
60 63 146
120
(Note) Always install a large capacity drive unit in the left side of power supply unit, and connect TE2(L+,L-) with DC connection bar.
[Unit : mm]
A4 - 4
Appendix 4. Explanation of Large Capacity Spindle Unit Specifications
(3) MDS-B-SP-370
180
AIR FLOW
Fin
L+
L–
L11 L21
U V W
60
4-ø6 hole
120
240
60 62 146 114
(Note) Always install a large capacity drive unit in the left side of power supply unit, and connect TE2(L+,L-) with DC connection bar.
[Unit : mm]
A4 - 5
Appendix 4. Explanation of Large Capacity Spindle Unit Specifications
(4) MDS-B-SP-450/550
2-M10 screw for I-bolt mounting
Only on top
180
AIR
FLOW
Fin
L11 L21
60
U V W
4-ø6 hole
180
300
60
L+
L–
63 146 120
(Note) Always install a large capacity drive unit in the left side of power supply unit, and connect TE2(L+,L-) with DC connection bar.
[Unit : mm]
A4 - 6
Appendix 4. Explanation of Large Capacity Spindle Unit Specifications
1) 45kW
(for wire connection)
6-M6 screw
M5 screw
FG connection position
(with grounding mark)
PE connection position
Terminal cover
MAIN
L11
L12
DRIVE
L21
L22
70
±1
L31
L32
4-8×15 slot
(mounting slot)
2) 55kW
6-M10 screw
(for wire connection)
M5 screw
FG connection position
4-10×15 slot
(mounting slot)
Terminal cover
MAIN
L11
L12
DRIVE
L21
L22
L31
L32
200
±1.5
PE connection position
(with grounding mark)
215
±2.5
220
±2.5
[Unit : mm]
ACL type
Compatible power supply unit
D
3
D Weight
B-AL-45K MDS-B-CVE-450 120 160 12.8kg
(6) DC connection bar
[Unit : mm]
ACL type
Compatible power supply unit
φ12
D
3
D Weight
B-AL-55K MDS-B-CVE-550 200
12 x 24 long hole
(17)
89
57.5
14.5
(Note) This DC connection bar is a set of two DC connection bars.
3
POINT
1. These DC connection bars are accessories.
2. Always install a large capacity drive unit in the left side of power supply unit, and connect TE2(L+,L-) with DC connection bar.
A4 - 7
Appendix 4. Explanation of Large Capacity Spindle Unit Specifications
Appendix 4-1-5 Panel cut dimension drawing
Square hole
Square hole
8-M5 screw
Spindle drive unit mounting side Power supply unit mounting side
(Front view)
Unit [mm]
Sym- bol
H
W
H1
H2
W1
W2
W3
W4
W5
Power supply unit
MDS-B-CVE-450 MDS-B-CVE-550
Symbol
360±0.3 360±0.3 H
Spindle drive unit
MDS-B-SPA-370 MDS-B-SPA-450 MDS-B-SPA-550
360±0.3 360±0.3 360±0.3
222±1 282±1 282±1
341±1 341±1 341±1
10±0.5 10±0.5 10±0.5
– – –
120±0.3 180±0.3 180±0.3
51±0.5 51±0.5 51±0.5
– – –
– – –
(Note 1) The spindle drive unit must be mounted to the left of the power supply unit looking from the front of the unit. The panel must be cut taking this into consideration.
(Note 2) L+ and L– connection conductors are enclosed with the MDS-B-CVE-450 and 550 capacities, so provide space between the units according to the dimensions shown above.
A4 - 8
Appendix 4. Explanation of Large Capacity Spindle Unit Specifications
Appendix 4-1-6 Heating value
Power supply unit Spindle drive unit
Heating value (W) Type Type
MDS-B-CVE-450
MDS-B-CVE-550
MDS-B-SPA-550
Heating value (W)
850
1000
1200
(Note 1) The heating value is the value at the continuous rated output.
(Note 2) Use the following expressions as a guide for the heating value outside the panel when mounting in an enclosed structure.
Unit Heating value outside panel
MDS-B-CVE-450, 550
Heating value outside panel =
(B-CVE heating value -30) × 0.75
MDS-B-SPA-370, 450, 550
Heating value outside panel =
(B-SPA heating value -40) × 0.75
Appendix 4-1-7 Selecting the power capacity
The power capacity required for the power supply unit is shown below.
Power supply unit type Power capacity (kVA)
MDS-B-CVE-450 63
MDS-B-CVE-550 77
Appendix 4-1-8 Selecting the wire size
(1) Recommended wire size for power lead-in wire
Regardless of the motor type, select the wire size as shown below using the power supply unit capacity as a reference.
Power supply unit type
MDS-B-CVE-450
MDS-B-CVE-550
Recommended wire size for power-lead-in wire
HIV60mm
2
HIV80mm
2
(2) Recommended wire size for spindle motor output wire
Regardless of the motor type, select the wire size as shown below using the spindle drive unit capacity as a reference.
Spindle drive unit type
MDS-B-SPA-370
MDS-B-SPA-450
MDS-B-SPA-550
Recommended wire size for spindle motor output wire
HIV50mm
2
HIV60mm
2
HIV80mm
2
(3) L+, L– link bar wire size
Power supply unit type
MDS-B-CVE-450
MDS-B-CVE-550
L+, L– link bar wire size
Dedicated link bars are enclosed as accessories (always use accessories)
Dedicated link bars are enclosed as accessories (always use accessories)
(Note) The wire sizes above for the MDS-B-CVE-450/550 are the values when connecting to the terminal section on the left front.
(4) L11, L21, MC1
Regardless of the spindle drive unit and power supply unit capacities, use an IV2mm
2
or more wire size.
A4 - 9
Appendix 4. Explanation of Large Capacity Spindle Unit Specifications
Appendix 4-1-9 Drive unit connection screw size
Power supply unit Spindle drive unit
Type
MDS-B-CVE-450 MDS-B-CVE-550
MDS-B-SPA-370
Left Right Left Right
MDS-B-SPA-450
MDS-B-SPA-550
L1, L2, L3
U, V, W
L+, L–
L11, L21
M8 M10 – –
M10 M6 M10 M6 M10 M10
MC1 M4 M4 – –
Appendix 4-1-10 Connecting each unit
NC
PC
DIO
The wiring system is the same as the MDS-C1-SPA Series. (Refer to the wiring system example below.)
Note that there are restrictions to the mounting and selection, so refer to the Restrictions given in
Section Appendix 5-1-11.
(a) When using MDS-C1-CV-370 or smaller
MDS-B-SPA(H)-370 to 550
MDS-C1-CV
-260 to 370
MDS-B-SPA(H)
-040 to 37
MDS-C1-SPA(H)
-55 to 300
L11 L21
L+
L-
U V W
L+
L11
L21
MC1
L1 L2 L3
L-
L21
U V W
L+
L-
L11
MC Contactor
MAG
ENC
Spindle motor
NFB
For motor blower
PLG
AC reactor
B-AL
NFB
NFB
For motor blower
PLG
Spindle motor
MAG
ENC
3φ 200VAC 50Hz
3φ 200 to 220VAC 60Hz
A4 - 10
NC
Appendix 4. Explanation of Large Capacity Spindle Unit Specifications
(b) When using MDS-B-CVE-450, 550
MDS-B-SPA(H)-370 to 550 MDS-B-CVE-450/550
MDS-B-SPA(H)
-040 to 37
MDS-C1-SPA(H)
-55 to 300
Always use the link bar enclosed with
B-CVE.
L11 L21
MAG
ENC
L+
L-
U V W
L+
L-
L11 L12 MC1
Upper step
L21 L22 MC2
Lower step
L1 L2 L3
Contactor
AC reactor
B-AL
L11
L21
U V W
PLG
Spindle motor
NFB
NFB
For motor blower
PLG
For motor blower
NFB
Spindle motor
MAG
3φ 200VAC 50Hz
3φ 200 to 220VAC 60Hz
(Note 1) Connect the L11, L21 and MC1 external connections without removing the conductors connected between L21 and L22, L22 and MC2, and L11 and L12 of the MDS-B-CVE-450,
550.
(L12, L22 and MC2 are for special specifications, and normally, the external connection is not required.)
(Note 2) Always connect the contactor to MC1 so that it can be controlled with the drive unit's internal signal. The power supply unit could be damaged if the contactor is turned ON and OFF with a separate user-prepared sequence.
(Note 3) One end of the contactor coil is connected to the MC1 terminal and the other end is connected to the power supply. The phase on the side connected to the power supply must be different from the phase connected to the power supply unit's L21.
A4 - 11
Appendix 4. Explanation of Large Capacity Spindle Unit Specifications
Appendix 4-1-11 Restrictions
(1) Mounting
Always mount the MDS-B-SPA-370,450, 550 on the left of the power supply unit.
When using MDS-B-CVE-450, 550, always use the enclosed link bar to connect L+ and L- on the
MDS-B-SP-370, 450, 550.
(a) Layout when connecting only one spindle drive unit to power supply unit.
Mount the power supply on the right and the spindle drive unit on the left.
Always cut the panel according to the panel cut dimension drawings shown in Appendix 5-1-5.
<Example 1>
MDS-B-SPA-450 MDS-B-CVE-450
(b) Layout when connecting multiple drive units to a large capacity power supply unit
The following number of spindle drive units can be additionally connected.
• When MDS-B-CVE-450 and MDS-B-SPA-370 are combined, 9kW (=45kW–37kW+1kW)
worth of units.
• When MDS-B-CVE-550 and MDS-B-SPA-450 are combined, 11kW (=55kW–45kW+1kW)
worth of units.
• When MDS-B-CVE-450 and MDS-B-SPA-370 are combined, 19kW (=55kW–37kW+1kW)
worth of units.
In this case, arrange the MDS-B-SPA-370, 450 to the left of MDS-B-CVE-450, 550 as shown in the panel cut dimension drawings in Appendix 5-1-5. Mount the additional drive units to the right of the MDS-B-CVE-450, 550.
If the spindle motor output differs from the spindle drive unit output, the above, excluding the layout, may not always apply. (This is because the power supply unit's output is determined by the motor output.)
<Example 2>
MDS-
B-SPA-370
MDS-
B-CVE-450
MDS-
B-SPA-37
(2-axis)
A4 - 12
Appendix 4. Explanation of Large Capacity Spindle Unit Specifications
(2) Selection
(a) When using the MDS-B-CVE-450, 550, one of the B-SPA-370, 450, 550 units must be selected for the drive units connected to this power supply unit.
Only one MDS-B-SPA-370, 450, 550 can be connected to one MDS-B-CVE-450, 550.
(b) When using MDS-B-SPA-370, 450 or 550, the following power supply unit must be selected.
• When using MDS-B-SPA-370: Select MDS-C1-CV-260 or more or MDS-B-CVE-450 or 550
• When using MDS-B-SPA-450: Select MDS-C1-CV-300 or more or MDS-B-CVE-450 or 550
• When using MDS-B-SPA-550: Select MDS-C1-CV-370 or more or MDS-B-CVE-450 or 550
Note that if the total of the spindle motor output corresponds to the above power supply unit with the normal selection method, that capacity power supply unit can be selected.
When total of servo/spindle motor output is 23kW or less: Select MDS-C1-CV-260
When total of servo/spindle motor output is 23.1kW or more: Select power supply unit with normal selection method.
When total of servo/spindle motor output is 27kW or less: Select MDS-C1-CV-300
When total of servo/spindle motor output is 27.1kW or more: Select power supply unit with normal selection method.
When total of servo/spindle motor output is 31kW or less: Select MDS-C1-CV-370
When total of servo/spindle motor output is 31.1kW or more: Select power supply unit with normal selection method.
A4 - 13
Appendix 4. Explanation of Large Capacity Spindle Unit Specifications
Appendix 4-1-12 Parameters
The parameters added and changed in respect to the 30kW or smaller drive unit are shown below. The parameters other than those shown below are the same as the 30kW or smaller capacity. For details on the parameters, refer to "MDS-C1 SERIES INSTRUCTION MANUAL" (BNP-B2365)
No. Abbr.
Parameter name
Standard
Details Setting setting
Set the spindle drive unit's capacity type.
(HEX setting)
Setting Unit capacity Setting Unit capacity
0000 --- 0010 MDS-B-SPA-550
0001 MDS-B-SPA-075 0011 ---
0002 MDS-B-SPA-15 0012 ---
--- 0003 MDS-B-SPA-22 0013
0004 MDS-B-SPA-37 0014
0005 MDS-B/C1-SPA-55 0015
SP039 ATYP* Drive unit type 0006 MDS-B/C1-SPA-75 0016
---
---
--- 0000 to FFFF 0000
--- 0007 MDS-B/C1-SPA-110 0017
0008 MDS-B/C1-SPA-150 0018
0009 MDS-B/C1-SPA-185 0019
000A MDS-B/C1-SPA-220 001A
000B MDS-B/C1-SPA-260 001B
000C MDS-B/C1-SPA-300 001C
000D MDS-B-SPA-370 001D
000E MDS-B-SPA-450 001E
000F MDS-B-SPA-04 001F
---
---
---
---
---
---
---
---
When the CN4 connector of the drive unit and the power supply are connected, setting below is necessary.
SP041 PTYP*
Power supply type
To validate the external emergency stop function, add
40h.
(HEX setting)
Unit capacity
External emergency stop invalid
External emergency stop valid
0000 to FFFF 0000
MDS-C1-CV-260
MDS-C1-CV-300
0126 0166
0130 0170
MDS-C1-CV-370
MDS-B-CVE-450
0137 0177
0145 0185
MDS-B-CVE-550 0155 0195
Parameters with an asterisk * in the abbreviation, such as ATYP*, are validated with the NC power turned ON again.
Appendix 4-1-13 Precautions
After turning the power OFF, wait at least 15 seconds before turning it ON again.
If the power is turned ON within 15 seconds, the drive unit's control power may not start up correctly.
A4 - 14
Appendix 5. Explanation of Small Capacity Spindle
Drive Unit Specifications
Appendix 5-1 Explanation of small capacity spindle drive unit specifications........................................A5-2
Appendix 5-1-1 Outline .......................................................................................................................A5-2
Appendix 5-1-2 List of units ................................................................................................................A5-2
Appendix 5-1-3 Outline dimension drawings ......................................................................................A5-2
Appendix 5-1-4 Drive unit specifications list .......................................................................................A5-4
Appendix 5-1-5 Heating value ............................................................................................................A5-5
Appendix 5-1-6 Selecting the wire size ..............................................................................................A5-5
Appendix 5-1-7 Drive unit connection screw size...............................................................................A5-5
Appendix 5-1-8 Restrictions................................................................................................................A5-6
A5 - 1
Appendix 5. Explanation of Small Capacity Spindle Drive Unit Specifications
Appendix 5-1 Explanation of small capacity spindle drive unit specifications
Appendix 5-1-1 Outline
MDS-C1-SPA Series spindle drive unit of 5.5kw or smaller are not available. Therefore, when the spindle drive unit of 3.7kw or smaller is required, use a spindle unit of MDS-B-SPA Series. In this section, the items about MDS-B-SPA which must be added to C1-SPA are explained. Use MDS-C1-CV for the power supply unit to be combined.
Appendix 5-1-2 List of units
Type
Capacity
(kW)
Weight
(kg)
MDS-B-SPA-04
MDS-B-SPA-075
MDS-B-SPA-15
MDS-B-SPA-22
0.4 3.5
0.75 3.5
1.5 3.5
2.2 4.5
MDS-B-SPA-37 3.7 4.5
(Note) Use the power supply unit MDS-C1-CV-37 or larger.
Appendix 5-1-3 Outline dimension drawings
(1) MDS-B-SPA-04 to 15
The front view drawing shows a state with the terminal cover removed.
Panel mounting hole machining drawing
+
2-M5 screw hole
L+
L-
L11
L21
U V W
30
60
2-ø6 hole
20
70
Wiring space
180
(Note 1) A square hole processing is not required in the panel mounting hole machining.
[Unit : mm]
(Note 2) Keep ventilation area in the top and bottom of unit because only MDS-B-SPA-15 has a built-in fan.
A5 - 2
Appendix 5. Explanation of Small Capacity Spindle Drive Unit Specifications
The front view drawing shows a state with the terminal cover removed.
Panel mounting hole machining drawing
52
2-M5 screw
L+
L-
L11
L21
U V W
30
60
2-ø6 hole
20
70
Wiring space
180
320
FAN
120
[Unit : mm]
A5 - 3
Appendix 5. Explanation of Small Capacity Spindle Drive Unit Specifications
Appendix 5-1-4 Drive unit specifications list
Spindle drive unit MDS-B-SPA Series
Spindle drive unit type
MDS-B-SPA-
MDS-B-SPAH-
04 075 15 22 37
0.1 0.3 0.5 1.5 2.2
AC 155
Rated output
Output
Input
[kW]
Rated voltage [V]
Rated current [A]
Rated voltage [V]
Rated current [A]
Control power
Voltage [V]
Frequency [Hz]
Current [A]
Control method
Braking
Speed control input
External analog output
Structure
Ambient temperature
DC270 to 311
AC200/200 to 230
50/60
Max. 0.2
Sine wave PWM control method, current control method
Regenerative braking
Analog voltage ±10V (or +10V) MAX (input impedance approx.10kΩ), or digital (12 bit binary, signed 12 bit binary, BCD code 2 digits, BCD code 3 digits)
0 to +10V, 2ch (speed meter output, load meter output, data for various adjustments)
Protection type (Protection method: IP20)
Operation: 0 to 55°C (with no freezing), Storage / Transportation: -15°C to 70°C (with no freezing)
Environ- ment
Ambient humidity
Atmosphere
Altitude
Operation: 90%RH or less (with no dew condensation)
Storage / Transportation: 90%RH or less (with no dew condensation)
Indoors (no direct sunlight)
With no corrosive gas, inflammable gas, oil mist or dust
Operation/Storage: 1000 meters or less above sea level,
Transportation: 10000 meters or less above sea level
4.9m/s
2
(0.5G) / 49m/s
2
(5.0G) Vibration/impact
Cooling method
[kg] Weight
Heat radiated at continuous rated output
Noise
[W]
Self-cooling Internal
3.5 4.5
30 40 50 70 80
Less than 55dB
A5 - 4
Appendix 5. Explanation of Small Capacity Spindle Drive Unit Specifications
Appendix 5-1-5 Heating value
Heating value
MDS-B-SPA-
Inside panel Outside panel
04
075
15
30 -
40 -
22
50 -
27 43
37 29 51
(Note 1) The heating value is the value at the continuous rated output.
Appendix 5-1-6 Selecting the wire size
(1) Recommended wire size for spindle motor output wire
Regardless of the motor type, select the wire size based on the spindle drive unit capacity as shown below.
MDS-B-SPA- IV wire (60 o
C) HIV wire (75 o
C)
04
075
2mm
2
15
22 3.5mm
2
2mm
2
37
(Note 1) The wire sizes recommended in (1) above are selected under the conditions that the ambient temperature is 30°C and three tubes are wired.
During actual use, select the wire based on the above reference while considering the ambient temperature, wire material, and wiring state.
(Note 2) To suppress the L+ and L– link bar size to the minimum required for each unit, select as shown below based on the total output current of the motor to be load.
First, obtain the motor output current of each drive unit based on the drive unit capacity.
Spindle motor (Decide according to the drive unit capacity )
Unit capacity MDS-B-SPA□-
Motor output current (A)
04 075 15 22 37
4 6 10 17 25
Regardless of the spindle drive unit capacities, use the wire size of IV2mm
2
or more.
Appendix 5-1-7 Drive unit connection screw size
Terminal name Screw size
U,V,W,G
L+,L-
L11,L21
M4
M6
M4
A5 - 5
Appendix 5. Explanation of Small Capacity Spindle Drive Unit Specifications
Appendix 5-1-8 Restrictions
CAUTION
1. Correctly transport the product according to its mass. Failure to observe this could result in injury.
2. Do not stack the product above the indicated limit.
3. Install the product on non-combustible material. Installation directly on or near combustible materials could result in fires.
4. When installing, always observe this manual and install on a place which can withstand the mass.
5. Do not get on the product, or place heavy objects on it. Failure to observe this could result in injury.
6. Use the product within the designated environment conditions.
7. Do not allow conductive matters such as screws or metal pieces, or combustible matters such as oil to enter the spindle drive unit.
8. Do not block the spindle drive unit's ventilation area. Failure to observe this could result in faults.
9. The spindle drive unit is a precision device. Do not drop it or apply strong impacts
10. Do not install or operate a spindle drive unit that is damaged or missing parts.
11. Consult with the Service Center or Service Station when storing the spindle drive unit after a long time.
(a) Each unit is designed to be installed in a cabinet such as a power distribution box. Avoid installation in a place exposed to direct sunlight, near heat generating objects or outdoors.
(b) The inner working environment (temperature, humidity, vibration, atmosphere) of the cabinet must be within the limits given in the "Specifications for each unit". The cabinet for the cutting machine must be a totally closed type cabinet.
(c) Make considerations so that inspections and replacement during maintenance is easy.
The space required around each unit's panel is shown in the outline dimension drawings.
(d) Each unit generates some heat, so leave a space on the top and bottom when installing other equipment or parts.
Refer to the outline drawing for the square hole dimensions. In this case, insert packing between the unit and power distribution box. Refer to the following installation examples for installing each unit.
40 160
Power distribution box
Power distribution box
Cover
Exhaust
Front
Rear
(Example. 1) Secure space for air flow when the machine is installed at the rear of the power distribution box.
Partition
Filter
Intake
(Example. 2) When the outdoor air cooling section is to protrude from the power distribution box, make sure that cutting chips, etc., do not enter the exhaust section.
A5 - 6
Appendix 5. Explanation of Small Capacity Spindle Drive Unit Specifications
CAUTION
1. Do not hold the front cover when transporting the spindle drive unit. The drive unit could fall off and cause injury.
2. Always observe the installation direction. Failure to do so could result in faults.
3. Provide the specified distance between the spindle drive unit and inner surface of the control panel or other devices. Failure to observe this could result in faults.
(Note 1) When installing in a poor environment (factory with high levels of oil mist), install a filter at the intake section of the partition showed with the dashed line in (d) item (Example 2).
(Note 2) Make sure that cutting chips from the drill, etc., do not enter the spindle drive unit when assembling the control panel.
(Note 3) Provide means so that oil, water and cutting chips, etc., do not enter the spindle drive unit from the control panel clearances or the ceiling fan.
(Note 4) When using the product in a place with high levels of harmful gases or dust, protect the spindle drive unit with air purging (feed in clean air from outside so that the pressure in the storage panel is higher than outside to prevent the entry of harmful gases or dust).
(2) Installation of cooling fan
Each unit (excluding types without fins) is individually provided with a cooling fan (FAN1 shown below). However, install additional fans (FAN2 shown below) by the user in consideration of operation continuity when fan stops due to degradation of the environment around the fan and improvement of maintenance.
When using the totally closed type unit installation method and the box structure in which cutting oil and dust, etc., easily enters the unit's fan + fan section (a structure where the fan may stop easily due to the working environment), the user should add a fan at the FAN2 position shown on the right. Carry out forced cooling with the velocity set to 2m/s or more. Also take the serviceability into consideration in this case.
Inside box Outside box
Wind direction
FAN1 (mounted on unit as standard)
FAN2 (Additionally installed by user)
* Install a finger guard for safety.
Due to the structure, heat will tend to accumulate at the top of each unit. Thus, install a fan in the power distribution box to agitate the heat at the top of each unit.
Wind direction
(Inside box)
FAN3
(Additionally installed by user)
Velocity 2m/s or higher
* Install a finger guard for safety.
A5 - 7
Front view of units
Appendix 6. Compliance to EU EC Directives
Appendix 6-1 Compliance to EC Directives ...........................................................................................A6-2
Appendix 6-1-1 European EC Directives............................................................................................A6-2
Appendix 6-1-2 Cautions for EC Directive compliance ......................................................................A6-2
A6 - 1
Appendix 6. Compliance to EU EC Directives
Appendix 6-1 Compliance to EC Directives
Appendix 6-1-1 European EC Directives
In the EU Community, the attachment of a CE mark (CE marking) is mandatory to indicate that the basic safety conditions of the Machine Directives (issued Jan. 1995), EMC Directives (issued Jan. 1996) and the Low-voltage Directives (issued Jan. 1997) are satisfied. The machines and devices in which the servo and spindle drive are assembled are the targets for CE marking.
(1) Compliance to EMC Directives
The servo and spindle drive are components designed to be used in combination with a machine or device. These are not directly targeted by the Directives, but a CE mark must be attached to machines and devices in which these components are assembled. The next section "EMC
Installation Guidelines", which explains the unit installation and control panel manufacturing method, etc., has been prepared to make compliance to the EMC Directives easier.
(2) Compliance to Low-voltage Directives
The MDS-C1-SPA Series units are targeted for the Low-voltage Directives. An excerpt of the precautions given in this specification is given below. Please read this section thoroughly before starting use.
A Self-Declaration Document has been prepared for the EMC Directives and Low-voltage
Directives. Contact Mitsubishi or your dealer when required.
Appendix 6-1-2 Cautions for EC Directive compliance
Use the Low-voltage Directive compatible parts for the servo/spindle drive and servo/spindle motor. In addition to the items described in this instruction manual, observe the items described below.
(1) Configuration
Isolating transformer
Circuit breaker
Electromagnetic contactor
AC reactor
CB MC
Drive unit
M
Use a type B (AC/DC detectable type) breaker
(2) Environment
Use the units under an Overvoltage Category II and Pollution Class of 2 or less environment as stipulated in IEC60664.
These units do not provide protection against electric shock and fire sufficient for the requirements of the Low-voltage Directive and relevant European standards by themselves, so provide additional protection (refer to 5.2.4 and 7.1.6.1 of EN50178)
Drive unit Motor
During operation
Storage
During transportation
During operation
Storage
During transportation
Ambient temperature
0°C to 55°C -15°C to 70°C -15°C to 70°C
Ambient temperature
0°C to 40°C -15°C to 70°C -15°C to 70°C
Humidity
Altitude
90%RH or less
1000m or less
90%RH or less
1000m or less
90%RH or less
13000m or less
Humidity
Altitude
80%RH or less
1000m or less
90%RH or less
1000m or less
90%RH or less
13000m or less
A6 - 2
Appendix 6. Compliance to EU EC Directives
[1] Use the power supply and servo/spindle drive unit under an Overvoltage Category II as stipulated in IEC60664.
[2] In case of Overvoltage Category III, connect the PE terminal of the units to the earthed-neutral of the star-connection power supply system.
[3] Do not omit the circuit breaker and electromagnetic contactor.
(4) Earthing
[1] To prevent electric shocks, always connect the servo/spindle drive unit protective earth (PE) terminal (terminal with mark) to the protective earth (PE) on the control panel.
[2] When connecting the earthing wire to the protective earth (PE) terminal, do not tighten the wire terminals together. Always connect one wire to one terminal.
PE terminal PE terminal
[3] Select the earthing wire size in accordance with Table 1 of EN60204-1.
(5) Wiring
[1] Always use crimp terminals with insulation tubes so that the connected wire does not contact the neighboring terminals.
Crimp terminal
Insulation tube
Wire
[2] Do not connect the wires directly.
[3] Select the size of the wires for input power supply to Power Supply unit in accordance with
Table 4 and 5 of EN60204-1.
A6 - 3
Appendix 6. Compliance to EU EC Directives
[1] Use EN/IEC Standards compliant parts for the circuit breaker and contactor.
[2] Select circuit breaker with instantaneous trip function. (Trip within 30 second when over current of 600%). Apply Annex C of EN60204-1 for sizing of the circuit breaker.
(7) Miscellaneous
[1] Refer to the next section "EMC Installation Guidelines" for methods on complying with the
EMC Directives.
[2] Ground the facility according to each country's requirements.
[3] The control circuit connector ( {) is safely separated from the main circuit ( ).
[4] Inspect the appearance before installing the unit. Carry out a performance inspection of the final unit, and save the inspection records.
Mitsubishi CNC
SH21 cable
Power supply unit Spindle drive unit Servo drive unit
SV1,2
(CSH21)
Battery unit
CN1A CN1A CN1B
CN4
CN1A CN1B
SH21 cable
CN4 CN8 CN4 CN3M
Tool end detector
CN7 CN3L
CN9 CN9 CN9
Tool end detector
External emergency stop input
CN23 CN6
CN20
CN2L
CN5 CN2M
No-fuse breaker
AC reactor
Contactor
R
S
T
Ground
Breaker MC
L1
L2
TE1
L3
MC1
L11
TE3
L+
TE2
L-
L21
L+
L-
L11
L21
TE3
TE1
U
V
W
TE2
Spindle motor
PLG
MU
MV
MW
L+
L-
TE1
TE2
L11
L21
TE3
LU
LV
LW
Servo motor
Motor end detector
Servo motor
Motor end detector
: Main circuit
: Control circuit
Ground Ground Ground
A6 - 4
Appendix 7. EMC Installation Guidelines
Appendix 7-1 Introduction ......................................................................................................................A7-2
Appendix 7-2 EMC instructions ..............................................................................................................A7-2
Appendix 7-3 EMC measures ................................................................................................................A7-3
Appendix 7-4 Measures for panel structure ...........................................................................................A7-3
Appendix 7-4-1 Measures for control panel unit.................................................................................A7-3
Appendix 7-4-2 Measures for door .....................................................................................................A7-4
Appendix 7-4-3 Measures for operation board panel .........................................................................A7-4
Appendix 7-4-4 Shielding of the power supply input section..............................................................A7-4
Appendix 7-5 Measures for various cables ............................................................................................A7-5
Appendix 7-5-1 Measures for wiring in panel .....................................................................................A7-5
Appendix 7-5-2 Measures for shield treatment...................................................................................A7-5
Appendix 7-5-3 Servomotor power cable ...........................................................................................A7-6
Appendix 7-5-4 Servomotor feedback cable ......................................................................................A7-6
Appendix 7-5-5 Spindle motor power cable........................................................................................A7-7
Appendix 7-5-6 Spindle motor feedback cable...................................................................................A7-7
Appendix 7-6 EMC countermeasure parts .............................................................................................A7-8
Appendix 7-6-1 Shield clamp fitting ....................................................................................................A7-8
Appendix 7-6-2 Ferrite core ................................................................................................................A7-9
Appendix 7-6-3 Power line filter........................................................................................................A7-10
Appendix 7-6-4 Surge protector........................................................................................................A7-15
A7 - 1
Appendix 7. EMC Installation Guidelines
Appendix 7-1 Introduction
EMC Instructions became mandatory as of January 1, 1996. The subject products must have a CE mark attached indicating that the product complies with the Instructions.
As the NC unit is a component designed to control machine tools, it is believed to be out of the direct
EMC Instruction subject. However, we would like to introduce the following measure plans to backup
EMC Instruction compliance of the machine tool as the NC unit is a major component of the machine tools.
(1) Methods for installation in control/operation panel
(2) Methods of wiring cable outside of panel
(3) Introduction of countermeasure parts
Mitsubishi is carrying out tests to confirm the compliance to the EMC Standards under the environment described in this manual. However, the level of the noise will differ according to the equipment type and layout, control panel structure and wiring lead-in, etc. Thus, we ask that the final noise level be confirmed by the machine manufacturer.
These contents are the same as the EMC INSTALLATION GUIDELINES (BNP-B8582-45).
For measures for CNC, refer to "EMC INSTALLATION GUIDELINES" (BNP-B2230).
Appendix 7-2 EMC instructions
The EMC Instructions regulate mainly the following two withstand levels.
Emission ..... Capacity to prevent output of obstructive noise that adversely affects external sources.
Immunity ..... Capacity not to malfunction due to obstructive noise from external sources.
The details of each level are classified as Table 1. It is assumed that the Standards and test details required for a machine are about the same as these.
Table 1
Class Name
Radiated noise
Emission
Conductive noise
Details
Electromagnetic noise radiated through the air
Electromagnetic noise discharged from power line
Generic
Standard
Standards for determining test and measurement
EN50081-2
EN61800-3
(Industrial environment)
EN55011
IEC61000-4-2
Immunity
Static electricity electrical discharge
Radiated magnetic field
Burst immunity
Conductive immunity
Power supply frequency field
Power dip
(fluctuation)
Example) Withstand level of discharge of electricity charged in a human body.
Example) Simulation of immunity from digital wireless transmitters
Example) Withstand level of noise from relays or connecting/disconnecting live wires
Example) Withstand level of noise entering through power line, etc.
Example) 50/60Hz power frequency noise
Example) Power voltage drop withstand level
Surge
Example) Withstand level of noise caused by lightning
IEC61000-4-3
EN61000-6-2
EN61800-3
(Industrial environment)
IEC61000-4-4
IEC61000-4-6
IEC61000-4-8
IEC61000-4-11
IEC61000-4-5
A7 - 2
Appendix 7. EMC Installation Guidelines
Appendix 7-3 EMC measures
The main items relating to EMC measures include the following.
(1) Store the device in an electrically sealed metal panel.
(2) Earth all conductors that are floating electrically. (Lower the impedance.)
(3) Wire the power line away from the signal wire.
(4) Use shielded wires for the cables wired outside of the panel.
(5) Install a noise filter.
Ensure the following items to suppress noise radiated outside of the panel.
(1) Securely install the devices.
(2) Use shielded wires.
(3) Increase the panel's electrical seal. Reduce the gap and hole size.
Note that the electromagnetic noise radiated in the air is greatly affected by the clearance of the panel and the quality of the cable shield.
Appendix 7-4 Measures for panel structure
The design of the panel is a very important factor for the EMC measures, so take the following measures into consideration.
Operation board panel
Door
Control panel
Appendix 7-4-1 Measures for control panel unit
(1) Use metal for all materials configuring the panel.
(2) For the joining of the top plate and side plates, etc., mask the contact surface with paint, and fix with welding or screws.
In either case, keep the joining clearance to a max. of 20cm for a better effect.
(3) Note that if the plate warps due to the screw fixing, etc., creating a clearance, noise could leak from that place.
(4) Plate the metal plate surface (with nickel, tin) at the earthing section, such as the earthing plate.
(5) The max. tolerable hole diameter of the openings on the panel surface, such as the ventilation holes, must be 3cm to 5cm. If the opening exceeds this size, use a measure to cover it. Note that even when the clearance is less than 3cm to 5cm, noise may still leak if the clearance is long.
Example)
Painting mask
Hole exceeding
3cm to 5cm
∗ Provide electrical conductance
A7 - 3
Painting mask
Max. joining clearance 20cm
Appendix 7. EMC Installation Guidelines
Appendix 7-4-2 Measures for door
(1) Use metal for all materials configuring the door.
(2) Use an EMI gasket or conductive packing for the contact between the door and control panel unit.
(3) The EMI gasket or conductive packing must contact at a uniform and correct position of the metal surface of the control panel unit.
(4) The surface of the control panel unit contacted with the EMI gasket or conductive packing must have conductance treatment.
EMI gasket
Packing
Control panel
Door
Carry out conductance treatment on sections that the EMI gasket contacts.
(5) As a method other than the above, the control panel unit and door can be connected with a plain braided wire. In this case, the panel and door should be contacted at as many points as possible.
Appendix 7-4-3 Measures for operation board panel
(1) Always connect the operation board and indicator with an earthing wire.
(2) If the operation board panel has a door, use an EMI gasket or conductive packing between the door and panel to provide electrical conductance in the same manner as the control panel.
(3) Connect the operation board panel and control panel with a sufficiently thick and short earthing wire.
Refer to the "EMC INSTALLATION GUIDELINES" BNP-B2230 for the NC for more details.
Appendix 7-4-4 Shielding of the power supply input section
(1) Separate the input power supply section from other parts in the control panel so that the input power supply cable will not be contaminated by radiated noise.
(2) Do not lead the power line through the panel without passing it through a filter.
Control panel
Drive unit
Power line filter
Radiated noise
Breaker AC input
Control panel
Drive unit
Shielding plate
Power line filter
Radiated noise
Breaker AC input
The power supply line noise is eliminated Use a metal plate, etc., for the shielding by the filter, but cable contains noise again because of the noise radiated in the control panel.
partition. Make sure not to create a clearance.
A7 - 4
Appendix 7. EMC Installation Guidelines
Appendix 7-5 Measures for various cables
The various cables act as antennas for the noise and discharge the noise externally. Thus appropriate treatment is required to avoid the noise.
The wiring between the drive unit and motor act as an extremely powerful noise source, so apply the following measures.
Appendix 7-5-1 Measures for wiring in panel
(1) If the cables are led unnecessarily in the panel, they will easily pick up the radiated noise. Thus, keep the wiring length as short as possible.
Noise Noise
Device Device Device Device Device Device
(2) The noise from other devices will enter the cable and be discharged externally, so avoid internal wiring near the openings.
Control panel Control panel
Device Device Device Device
Noise
(3) Connect the control device earthing terminal and earthing plate with a thick wire. Take care to the leading of the wire.
Appendix 7-5-2 Measures for shield treatment
Common items
Use of shield clamp fittings is recommended for treating the shields. The fittings are available as options, so order as required. (Refer to section "6.1 Shield clamp fitting".)
Clamp the shield at a position within 10cm from the panel lead out port.
POINT
1. When leading the cables, including the grounding wire (FG), outside of the panel, clamp the cables near the panel outlet (recommendation: within
10cm).
2. When using a metal duct or conduit, the cables do not need to be clamped near the panel outlet.
3. When leading cables not having shields outside the panel, follow the instructions given for each cable. (Installation of a ferrite core, etc., may be required.)
A7 - 5
Appendix 7. EMC Installation Guidelines
Appendix 7-5-3 Servomotor power cable
Control panel
Control panel
Earth with paint mask
Conduit connector
Earth with P or U clip
Cannon connector To drive unit
Cannon connector
To drive unit
Servomotor
Servomotor
Conduit
Shield cable Cabtyre cable
Using shield cable Using conduit
(1) Use four wires (3-phase + earthing) for the power cable that are completely shielded and free from breaks.
(2) Earth the shield on both the control panel side and motor chassis side.
(3) Earth the shield with a metal P clip or U clip.
(A cable clamp fitting can be used depending on the wire size.)
(4) Directly earth the shield. Do not solder the braided shield onto a wire and earth the end of the wire.
Solder
(5) When not using a shield cable for the power cable, use a conventional cabtyre cable. Use a metal conduit outside the cable.
(6) Earth the power cable on the control panel side at the contact surface of the conduit connector and control panel. (Mask the side wall of the control panel with paint.)
(7) Follow the treatment shown in the example for the conduit connector to earth the power cable on the motor side. (Example: Use a clamp fitting, etc.)
Clamp fitting
To earthing
Conduit
Conduit connector
Appendix 7-5-4 Servomotor feedback cable
Control panel
Cannon connector
Use a conventional batch shield pair cable for the servomotor feedback cable, and ground it in the NC side
(control panel).
Cannon connector
To drive unit
Batch shield pair cable
A7 - 6
Appendix 7. EMC Installation Guidelines
Appendix 7-5-5 Spindle motor power cable
Control panel
Control panel
Earth with
P or U clip
Terminal box
Earth with paint mask
Conduit connector Terminal box
To drive unit
To drive unit
Conduit
Shield cable
Spindle motor
Using shield cable
Cabtyre cable
Using conduit
(1) Use four wires (3-phase + earthing) for the power cable that are completely shielded and free from breaks.
(2) Earth the shield in the same manner as the servomotor power cable.
(3) When not using a shield cable for the power cable, use a conventional cabtyre cable. Use a metal conduit outside the cable.
(4) Earth the power cable on the control panel side at the contact surface of the conduit connector and control panel side wall in the same manner as the servomotor power cable. (Mask the side wall of the control panel with paint.)
(5) Earth at the conduit connector section in the same manner as the servomotor power cable.
Appendix 7-5-6 Spindle motor feedback cable
Control panel
Clamp the shield, and connect to the connector case.
Terminal box
To drive unit
Spindle side connector
(State with the cover removed)
Batch shield pair cable
(1) Use a conventional batch shield pair cable for the spindle motor feedback cable.
Note) A shield for the spindle motor feedback cable is not "FG", and therefore do not ground it.
A7 - 7
Appendix 7. EMC Installation Guidelines
Appendix 7-6 EMC countermeasure parts
Appendix 7-6-1 Shield clamp fitting
The effect can be enhanced by connecting the cable directly to the earthing plate. Install an earthing plate near each panel's outlet (within 10cm), and press the cable against the earthing plate with the clamp fitting. If the cables are thin, several can be bundled and clamped together. Securely earth the earthing plate with the frame ground. Install directly on the cabinet or connect with an earthing wire.
Contact Mitsubishi if the earthing plate and clamp fitting set (AERSBAN- SET) is required.
• Outline drawing
View of clamp section
AERSBAN-DSET
AERSBAN-ESET
100
70
86
56
30
–
Note 1) Screw hole for wiring to earthing plate in cabinet.
Note 2) The earthing plate thickness is 1.6mm.
Clamp fitting A
× 2
Clamp fitting B
× 1
Clamp fitting A
Clamp fitting B
L
70
45
CAUTION
The shield of the spindle detector cable is not connected to the "FG"(Earth). Do not connect the cable shield to the earth by clamping the cable, etc.
A7 - 8
Appendix 7. EMC Installation Guidelines
Appendix 7-6-2 Ferrite core
A ferrite core is integrated and mounted on the plastic case.
Quick installation is possible without cutting the interface cable or power cable.
This ferrite core is effective against common mode noise, allowing measures against noise to be taken without affecting the signal quality.
Recommended ferrite core
TDK ZCAT Series
Shape and dimensions
ZCAT type
A
B
D
C
ZCAT-A type
A
B
E
C
ZCAT-B type
A
B
Fig. 1
E
ZCAT-C type
A
Fig. 2
Fig. 3 Fig. 4
ZCAT3035-1330 (-BK)*
1
ZCAT2035-0930-M (-BK)
ZCAT2017-0930-M (-BK)
ZCAT2749-0430-M (-BK)
Unit [mm]
Applicable
Weight
Recommended ferrite core
1 39 34 13 30 --- 13 63
2 35 29 13 23.5
4 49 27 4.5
19.5
22 10 29
9 12
--- 4.5 26
*1 A fixing band is enclosed when shipped.
ZCAT-B type: Cabinet fixed type, installation hole ø4.8 to 4.9mm, plate thickness 0.5 to 2mm
ZCAT-C type: Structured so that it cannot be opened easily by hand once closed.
A7 - 9
Appendix 7. EMC Installation Guidelines
Appendix 7-6-3 Power line filter
(1) Power line filter for 200V
HF3000A-TM Series for 200V
Features
• 3-phase 3-wire type (250V series, 500V series)
• Compliant with noise standards German Official Notice Vfg243,
EU Standards EN55011 (Class B)
• Effective for use with IGBT inverter and MOS-FET inverter.
• Easy mounting with terminal block structure, and outstanding reliability.
Application
• Products which must clear noise standards German Official
Notice Vfg243 and EU Standards EN55011 (Class B).
• For input of power converter using advanced high-speed power device such as IGBT MOS-FET.
Specifications (250V series)
Part name
HF3005A HF3010A HF3015A HF3020A HF3030A HF3040A HF3050A HF3060A HF3080A HF3100A HF3150A
-TM -TM -TM -TM -TM -TM -TM -TM -TM -TM -TM
Rated voltage 250VAC
Rated current 5A 10A 15A 20A 30A 40A 50A 60A 80A 100A
Leakage current 1.5mA MAX 250VAC 60Hz
Contact: Soshin Electric Co., LTD. Telephone: 03-3775-9112 (+81-3-3775-9112) http://www.soshin.co.jp
<Example of measuring voltage at noise terminal> ... Measured with IGBT inverter
150A
German Official Notice Vfg243 measurement data EU Standards EN55011 (Class B)
A7 - 10
<Typical characteristics>
Appendix 7. EMC Installation Guidelines
40A item
<Circuit diagram>
(250V series)
Outline dimensions
(500V series)
[ Unit : mm ]
Part name
Dimensions
A B C
HF3005A-TM
HF3010A-TM
HF3015A-TM
180 170 130
HF3020A-TM
HF3030A-TM
260 155 140
HF3040A-TM
HF3050A-TM
HF3060A-TM
290 190
170
230
HF3080A-TM
405 220
HF3100A-TM
HF3150A-TM 570 230
210
A7 - 11
Appendix 7. EMC Installation Guidelines
200V MX13 Series 3-phase high attenuation noise filter
Features
• Perfect for mounting inside control panel:
New shape with uniform height and depth dimensions
• Easy mounting and maintenance work:
Terminals are centrally located on the front
• Complaint with NC servo and AC servo noise:
High attenuation of 40dB at 150KHz
• Safety Standards:
UL1283, CSA22.2 No.8, EN133200
• Patent and design registration pending
Specifications
Type
MX13030 MX13050 MX13100 MX13150
Item
1 Rated voltage (AC)
2 Rated current (AC)
3
Test voltage (AC for one minute across terminal and case)
4
Insulation resistance
(500VDC across terminal and case)
5 Leakage current (250V, 60Hz)
3-phase 250VAC (50/60Hz)
2500VAC (100mA) at 25°C, 70% RH
100M
Ω min. at 25°C, 70% RH
8 Working ambient temperature
9 Working ambient humidity
10 Storage ambient temperature
11 Storage ambient humidity
12 Weight (typ)
3.5 mA max.
30 m
Ω max.
11 m
Ω max.
30°C max
8 mA max.
5.5 m
Ω max.
3.5 m
Ω max.
–25°C to +85°C
30% to 95% RH (non condensing)
–40°C to +85°C
10% to 95% RH (non condensing)
2.8kg 3.9kg 11.5kg 16kg
(Note) This is the value at Ta
≤50°C.
Refer to the following output derating for Ta>50°C.
Contact : Densei-lambda Co., Ltd. Telephone : 03-3447-4411 (+81-3-3447-4411)
Fax : 03-3447-7784 (+81-3-3447-7784)
http://www.densei-lambda.com
A7 - 12
Appendix 7. EMC Installation Guidelines
Example of using MX13 Series
This is a noise filter with the same dimensions as MDS-D/DH drive unit depth (200mm) and height
(380mm). This unit can be laid out easily in the device by arranging it in a row with the servo unit.
As with the servo unit, the terminals are arranged on the front enabling ideal wire lead-out.
Refer to the following usage examples for details.
Wire to 3-phase power supply
Noise filter input terminal
200
380
Noise filter (MX13 Series)
Servo unit
Servo input terminal
Example of noise terminal voltage attenuation
Wire from noise filter to servo
Noise filter output terminal
Frequency [MHz] Frequency [MHz]
EMI data for independent control panel EMI data for control panel + noise filter
(with six-axis servo unit mounted) (MX13030)
Output derating
Ambient temperature Ta (°C)
A7 - 13
Outline drawing
MX13030, MX13050
Appendix 7. EMC Installation Guidelines
[ Unit : mm ]
MX13030 MX13050
A
B
C
D
E
F
66 81
45 55
10.5 13
50 67
13 16
10 13
G 177 179
H M4 screw M6 screw
I 70 85
J M4 screw M6 screw
K 195 200
MX13100, MX13150
(Installation hole) (Installation hole)
[ Unit : mm ]
A
B
C
D
E
130 165
90 110
20 27.5
115 150.5
37.5 57.5
J
K
L
F
G
18 23
174 176
H M6 screw M8 screw
I 21 27
37.5 56.5
115 149.5
276 284
A7 - 14
Appendix 7. EMC Installation Guidelines
Appendix 7-6-4 Surge protector
Insert a surge protector in the power input section to prevent damage to the control panel or power supply unit, etc. caused by the surge (lightning or sparks, etc.) applied on the AC power line.
Use a surge protector that satisfies the following electrical specifications.
(1) Surge protector for 200V
R•A•V BYZ series for 200V
Part name
Circuit voltage
50/60Hz Vrms
Maximum tolerable circuit voltage
Clamp voltage
(V) ±10%
Surge withstand level
8/20µs (A)
Surge withstand voltage
1.2/50µs (V)
Electrostatic capacity
Service temperature
RAV-781BYZ-2 3AC 250V 300V 783V 2500A 20kV 75pF -20 to 70°C
(Note) Refer to the manufacturer's catalog for details on the surge protector's characteristics and specifications, etc.
(1) Black (2) Black (3) Black
0 0
UL-1015 AWG16
41 1
R•A•V BXZ series for 200V unit: mm
Part name
Circuit voltage
50/60Hz Vrms
Maximum tolerable circuit voltage
Clamp voltage
(V) ±10%
Surge withstand level
8/20µs (A)
Surge withstand voltage
1.2/50µs (V)
Electrostatic capacity
Service temperature
RAV-781BXZ-4 3AC 250V 300V 1700V 2500A 2kV 75pF -20 to 70°C
(Note) Refer to the manufacturer's catalog for details on the surge protector's characteristics and specifications, etc. diagram
(1)Black (2)Black (3)Black
U Green
0 0
UL-1015 AWG16
41 1
A7 - 15 unit: mm
Appendix 7. EMC Installation Guidelines
(2) Example of surge protector installation
Factory power
Input power supply
Grounding
An example of installing the surge protector in the machine control panel is shown below.
A short-circuit fault will occur in the surge protector if a surge exceeding the tolerance is applied.
Thus, install a circuit protection breaker in the stage before the surge protector. Note that almost no current flows to the surge protector during normal use, so a breaker installed as the circuit protection for another device can be used for the surge protector.
Panel earth leakage breaker Breaker
Breaker
B
Grounding plate
A
Transformer
Contactor
MC
Breaker
AC reactor
NC unit
Other device
(panel power supply, etc.)
Power supply unit and drive unit
Other device
(panel power supply, etc.)
(1) Surge protector
(Protection across phases)
Control panel
(relay panel,
etc.)
(2) Surge protector
(Protection across each phase's grounding)
Installing the surge absorber
CAUTION
1. The wires from the surge protector should be connected without extensions.
2. If the surge protector cannot be installed just with the enclosed wires, keep the wiring length of A and B to 2m or less. If the wires are long, the surge protector's performance may drop and inhibit protection of the devices in the panel.
3. The selected surge protector differs according to the input power voltage.
A7 - 16
Appendix 8. Instruction Manual for Compliance with
UL/c-UL Standard
Appendix 8 Instruction Manual for Compliance with UL/c-UL Standard.............................. A8-2
A8 - 1
Appendix 8. Instruction Manual for Compliance with UL/c-UL Standard
Instruction Manual for Compliance with UL/c-UL Standard
The instruction of UL/c-UL listed products is described in this manual.
The descriptions of this manual are conditions to meet the UL/c-UL standard for the UL/c-UL listed products. To obtain the best performance, be sure to read this manual carefully before use.
To ensure proper use, be sure to read specification manual, connection manual and maintenance manual carefully for each product before use.
1. UL/c-UL listed products
[CNC system]
Unit name Unit part number
NC control panel
Display unit
Keyboard unit
Base I/O unit
FCU6-MU [*1]-[*2], FCU6-MA [*1]-[*2]
FCU6-DU [*39][*40], FCU6-YZ [*39][*40]
FCUA-LD [*41], FCUA-CT [*41], FCUA-CR [*41]
FCU6-YZ [*39][*40], FCU6-TZ [*39][*40]
FCU6-KB0 [*42], FCUA-KB [*42]
FCU6-DX [*3], HR377, HR378, HR353
Remote I/O unit FCUA-DX [*4]
I/O module HR357, HR371, QY231
[AC servo/spindle system]
Unit name Unit part number
Power supply unit
Servo drive unit
Spindle drive unit
Option unit
Battery unit
Servo motor
Spindle Motor
MDS-B-CVE- [*5], MDS-C1-CV-[*5]
MDS-B-V1- [*6], MDS-B-V14- [*6], MDS-C1-V1- [*6]
MDS-B-V2- [*7], MDS-B-V24- [*7], MDS-C1-V2- [*7]
MDS-B-SVJ2- [*8]
MDS-B-SP [*38]-[*9], MDS-C1-SP [*38]-[*9]
MDS-C1-SPA[*43]-[*44][*45]
MDS-B-PJEX
FCU6-BT4D1
HA-FF [*10][*11][*12][*13][*14][*15][*16][*17][*18][*19]
HC-MF [*10][*11][*12][*13][*14][*15][*16][*17][*18][*19]
HC-SF [*10][*11][*12][*13][*14][*15][*16][*17][*18][*19]
HC-RF [*10][*11][*12][*13][*14][*15][*16][*17][*18][*19]
HC [*20][*11][*21][*14][*22]-[*23][*24]
SJ [*25][*26][*27]-[*28][*29][*30][*31]-[*32]
SJ [*33][*26][*28][*34][*35][*36][*37][*31]
Suffixes listed below may be attached to the above part numbers at portions marked with [*]. For details regarding specifications, see the specification manuals for each product.
[*1] 011, 013, 021, 031, 032, 515, 516, 517, 535, 536
[*3] 210, 211, 220, 221, 310, 311, 320, 321, 330, 331, 340, 341, 350, 351, 410, 411, 420, 421, 430, 431, 440, 441, 450, 451
[*4] 100, 101, 110, 111, 120, 121, 130, 131, 140, 141
[*5] 37, 55, 75, 110, 150, 185, 220, 260, 300, 370,(450, 550: Only MDS-B Series)
[*6] 01, 03, 05, 10, 20, 35, 45S, 45, 70, 90, 110, 150
[*7] 0101, 0301, 0303, 0501, 0503, 0505, 1003, 1005, 1010, 2010, 2020, 3510S, 3510, 3520S, 3520, 3535, 4520, 4535, 4545,
7035, 7045, 7070S, 7070
[*8] 01, 03, 04, 06, 07, 10, 20
[*9] 04, 075, 15, 22, 37, 55, 75, 110, 150, 185, 220, 260, 300, 370, (450,550:Only MDS-B Series)
[*10] 05, 1, 2, 3, 4, 5, 6, 7, 8, 10, 12, 15, 20, 30, 35
[*11] 1, 2, 3 [*12] None, C
[*13] None, P, N, I, E [*14] None, B
[*15] None, Gn, GnH (n = serial number) [*16] None, K, D, X, T
[*17] None, Wn (n = serial number)
[*19] None, Sn (n = serial number)
[*21] None, R
[*23] E, A
[*18] None, UL, UE
[*20] 5, 10, 15, 20, 35, 45, 70
[*22] S, T
[*24] 1, 2, 33, 42, 51
[*25] NL, PF, PL, V, VL
[*27] None, S
[*29] 01 - 99
[*31] None, M
[*33] None, N, P
[*35] None, 1 - 9, A - F
[*37] None, B, C, F, G, R
[*39] T, C, N
[*41] 10, 100, 120
[*43] None, H
[*44] 55,75,110,150,185,220,260,300
[*45] None, R,D,T,RD,RT
[*26] None, K
[*28] Two digits decimal two digits
[*30] None, F, G, Y, Z
[*32] None, S01 - S99
[*34] A, B, L, M, N, X
[*36] None, D, H, P, Z
[*38] None, H, M, X, HX, MX
[*40] 31, 32, 33, 34, 35, 36
[*42] 05, 06, 10, 13, 14, 20, 30
A8 - 2
Appendix 8. Instruction Manual for Compliance with UL/c-UL Standard
2. Operation surrounding air ambient temperature
The recognized operation ambient temperature of each units are as shown in the table below. The recognized operation ambient temperatures are the same as an original product specification for all of the units. temperature
CNC system
AC servo/spindle system
NC control panel
Base I/O unit
Remote I/O unit
I/O module
Power supply unit
Servo drive unit
Spindle drive unit
Option unit, Battery unit
Servo motor, Spindle Motor
0 to 55
°C
0 to 55
°C
0 to 55
°C
0 to 55
°C
0 to 55
°C
0 to 55
°C
0 to 55
°C
0 to 55
°C
0 to 40
°C
3. Notes for CNC system
3.1 Selection of external power supply unit
An UL recognized 24Vdc output power supply unit should be used to CNC system.
The “PD25” power supply unit provided by Mitsubishi will be changed to UL recognized product since
September 2000.
4. Notes for AC servo/spindle system
4.1 General Precaution
It takes 10 minutes to discharge the bus capacitor.
When starting wiring or inspection, shut the power off and wait for more than 15 minutes to avoid a hazard of electrical shock.
4.2 Installation
MDS-B/C1 Series have been approved as the products, which have been installed in the electrical enclosure. The minimum enclosure size is based on 150 percent of each MDS-B/C1 unit combination.
And also, design the enclosure so that the ambient temperature in the enclosure is 55
°C (131°F) or less, refer to the manual book
4.3 Short-circuit ratings
Suitable for use in a circuit capable of delivering, it is not more than 5kA rms symmetrical amperes.
A8 - 3
Appendix 8. Instruction Manual for Compliance with UL/c-UL Standard
4.4 Peripheral devices
To comply with UL/c-UL Standard, use the peripheral devices, which conform to the corresponding standard.
• Circuit Breaker, Fuses, Magnetic Contactor and AC Reactor
Applicable power supply unit
Circuit Breaker
Fuse
Class K5
MDS-B-CVE-37
MDS-C1-CV-37
MDS-B-CVE-55
MDS-C1-CV-55
MDS-B-CVE-75
MDS-C1-CV-75
MDS-B-CVE-110
MDS-C1-CV-110
MDS-B-CVE-150
MDS-C1-CV-150
MDS-B-CVE-185
MDS-C1-CV-185
MDS-B-CVE-220
MDS-C1-CV-220
MDS-B-CVE-260
MDS-C1-CV-260
NF50 40A
NF50 40A
NF50 40A
NF50 50A
NF100 100A
NF100 100A
NF225 150A
NF225 150A
70A
100A
100A
100A
200A
200A
200A
300A
MDS-B-CVE-300
MDS-C1-CV-300
MDS-B-CVE-370
MDS-C1-CV-370
NF225 150A
NF225 175A
MDS-B-CVE-450 NF225 200A
MDS-B-CVE-550 NF400 300A
300A
300A
• Circuit Breaker for spindle motor Fan
Magnetic contactor (AC3)
S-N25
S-N25
S-N25
S-N35
S-N50
S-N50
S-N80
S-N80
S-N80
S-N150
S-N150
S-N180
AC Reactor
BKO-NC6851-
H11 (B-AL-7.5K)
H11 (B-AL-7.5K)
H11 (B-AL-7.5K)
H12 (B-AL-11K)
H13 (B-AL-18.5K)
H13 (B-AL-18.5K)
H14 (B-AL-30K)
H14 (B-AL-30K)
H14 (B-AL-30K)
H15 (B-AL-37K)
H16 (B-AL-45K)
H17 (B-AL-55K)
Select the Circuit Breaker by doubling the spindle motor fan rated.
A rush current that is approximately double the rated current will flow, when the fan is started.
<Notice>
• For installation in United States, branch circuit protection must be provided in accordance with the National Electrical Code and any applicable local codes.
• For installation in Canada, branch circuit protection must be provided in accordance with the Canadian Electrical Code and any applicable provincial codes.
4.5 Flange of servo motor
Mount the servomotor on a flange, which has the following size or produces an equivalent or higher heat dissipation effect:
Flange size
(mm)
Servo Motor
HC HC-RF HC-MF HA-FF HC-SF
150x150x6 --- --- Under 100W Under 100W ---
250x250x6 --- ---
250x250x12 0.5 to 1.5kW 1.0 to 2.0kW
200W
400W 400,600W
---
0.5 to 1.5kW
300x300x20 2.0 to 7.0kW
--- --- --- 2.0 to 7.0kW
4.6 Motor Over Load Protection
Servo drive unit MDS-B-V1/2/14/24 Series and MDS-C1-V1/2 series and spindle drive unit MDS-B-SP and MDS-C1-SP series have each solid-state motor over load protection.
When adjusting the level of motor over load, set the parameter as follows.
A8 - 4
Appendix 8. Instruction Manual for Compliance with UL/c-UL Standard
4.6.1 MDS-B-V1/2/14/24, MDS-C1-V1/2 Series
Parameter
No.
Parameter
Abbr.
Parameter
Name
Setting Procedure
Standard
Setting Value
Setting
Range
60s 1 to 300s SV021 OLT Overload
Time constant
Set the time constant for overload detection. (Unit: 1 second.)
SV022 OLL Overload
Detection level
Set the overload current detection level with a percentage (%) of the stall rating.
4.6.2 MDS-B-SP, MDS-C1-SP, MDS-C1-SPA Series
Parameter
No.
Parameter
Abbr.
Parameter
Name
Setting Procedure
150%
Standard
Setting Value
1 to 500%
Setting
Range
SP063 OLT Overload
Time constant
Set the time constant for overload detection. (Unit: 1 second.)
60s 0 to 1000s
SP064 OLL Overload
Detection level
Set the overload current detection level with a percentage (%) of the rating.
110% 1 to 200%
4.7 Field Wiring Reference Table for Input and Output
Use the UL-approved Round Crimping Terminals to wire the input and output terminals of MDS-B
Series.
Crimp the terminals with the crimping tool recommended by the terminal manufacturer.
Following described crimping terminals and tools type are examples of Japan Solderless Terminal Mfg.
Co., Ltd.
4.7.1 Power Supply Unit (MDS-B-CVE, MDS-C1-CV Series)
3.7 to 7.5 11.0 to 18.5 22.0 to 37.0
45.0 55.0 Capacity [kW]
P, N
(L+, L-)
M6 M6 M6 M6,
Terminal
Screw Size
Screw Torque
[lb in/ N m]
L11, L21, MC1
(R0, S0)
Screw Torque
[lb in/ N m]
L1, L2, L3
Screw Torque
[lb in/ N m]
44.3/5.0 49.6/5.6
17.4/2.0 14.2/1.6
49.6/5.6
M4 M4 M4 M4 M4
14.2/1.6
14.2/1.6
M4 M5 M8 M8 M10
14.6/1.6 29.8/3.37
117.2/13.2 117.2/13.2
14.6/1.6
177/20
P, N (L+, L-)
Capacity [kW]
Wire Size (AWG)
3.7, 5.5
#10/60
7.5
°C #8/60°C
11.0
#4/60
°C
15.0
#4/60
°C
/Temp Rating Note 1 #12/75
°C #10/75°C #8/75°C
#4/75
°C
Crimping Terminals
Type
R5.5-6
R8-6 R22-6
R5.5-6 R8-6
R22-6
18.5, 22.0
#3/60
°C
#4/75
°C
Crimping Tools Type YHT-2210
YHT-8S YPT-60
YHT-2210 YHT-8S
YPT-60
Capacity [kW]
Wire Size (AWG)
/Temp Rating Note 1
26.0 30.0 37.0 45.0 55.0
#1/60
°C
#3/75
°C
#1/75
°C #1/0/75°C
The bus bar is attached to the product.
Crimping Terminals
Type
38-S6
R22-6
38-S6
L330T
459-12
Crimping Tools Type YPT-60
YET300
YF-1
A8 - 5
Appendix 8. Instruction Manual for Compliance with UL/c-UL Standard
L11, L21 (R0, S0), MC1
Capacity [kW]
Wire Size (AWG)
/Temp Rating Note 1
Crimping Terminals
Type
Crimping Tools Type
3.7 to 55.0
#14/ 60
°C
#14/ 75
°C
V2-4
YNT-1614
L1, L2, L3
Capacity [kW]
Wire Size (AWG)
/Temp Rating Note 1
Crimping Terminals
Type
Crimping Tools Type
Earth Wire Size
(AWG)
#10/60
°C #10/60°C
#12/75
°C #10/75°C
#10/75
°C
#4/60
°C
#3/60
°C
#4/75
°C
#4/75
°C
#3/75
°C
Capacity [kW]
Wire Size (AWG)
/Temp Rating Note 1
Crimping Terminals
Type
Crimping Tools Type
Earth Wire Size
(AWG)
Terminal
Screw
Size
22.0 26.0 30.0 37.0 45.0 55.0
#1/60
°C #1/0/60°C
#2/75
°C #1/75°C
#1/75
°C
1/0/75
°C
#2/0
/75
°C
#3/0
/75
°C
38-S8
L330T
459-12 38-S8
L330T
459-12
70-8 R80-10
38-S8
YPT-60
YET300
YF-1
YPT-60
#3/60
°C #1/60°C
#3/75
°C #3/75°C
YPT-60
#3/75
°C
YET300
YF-1
1/75
°C
#1/75
YTP-150
°C
#1/0
/75
°C
4.7.2 Servo Drive Unit (MDS-B-V1/2/14/24, MDS-C1-V1/2 Series)
Axis 1-axis (V1, V14) 2-axes (V2, V24)
Capacity [kW] 0.1 to 3.5 4.5 to 9.0
11.0,
15.0
0.1+0.1 to 7.0+7.0
P, N
(L+, L-)
Screw
Torque
[lb in/ N m]
L11, L21
(R0, S0)
Screw
Torque
[lb in/ N m]
U, V, W
Screw
Torque
[lb in/ N m]
M6 M6 M6
44.3/5.0 44.3/5.0
44.3/5.0
M4 M4 M4
17.4/2.0 17.4/2.0
17.4/2.0
M4 M5 M8
14.6/1.6 28.6/3.2
117.2/13.2
M6
44.3/5.0
M4
17.4/2.0
M4
14.6/1.6
P, N (L+, L-)
YHT-2210 YPT-60
#10/60
°C #10/60°C
#10/75
°C #10/75°C
#10/75
°C
#4/60
#4/75
°C
°C
#3/60
#4/75
°C
°C
#3/75
°C
Wire size depends on the Power Supply Unit (MDS-B-CVE, MDS-C1-CV Series).
L11, L21 (R0, S0)
Capacity [kW]
Wire Size (AWG)
/Temp Rating Note 1
Crimping Terminals
Type
Crimping Tools Type
0.1 to 15.0
#14/ 60
°C
#14/ 75
°C
V2-4
YNT-1614
A8 - 6
Appendix 8. Instruction Manual for Compliance with UL/c-UL Standard
U, V, W
Capacity [kW] 0.1 to 1.0 2.0 3.5 4.5
Wire Size (AWG) #14/60
°C #10/60°C
#8/60
°C
#8/60
°C
/Temp Rating Note 1 #14/75
°C #14/75°C #10/75°C #10/75°C
Crimping Terminals
Type
R2-4
R5.5-4 8-4
R8-5
(8-4)
R5.5-5
(R5.5-4)
Crimping Tools Type
Earth wire Size
(AWG)
YHT-2210
YHT-8S
YHT-2210
#14/60
°C #10/60°C
#8/60
°C
#8/60
°C
#14/75
°C #12/75°C #10/75°C #10/75°C
Capacity [kW]
Wire Size (AWG) #8/60
°C #8/60°C
#4/60
°C
/Temp Rating Note 1 #8/75
°C #8/75°C
#4/75
°C
Crimping Terminals
Type
R8-5
(8-4)
#2/60
#3/75
°C
°C
R8-5 R22-8 R38-8
Crimping Tools Type
Earth Wire Size
(AWG)
YHT-8S YPT-60
#8/60
°C #8/60°C
#4/60
°C
#8/75
°C #8/75°C
#4/75
°C
#3/60
#3/75
°C
°C
4.7.3 Spindle Drive Unit (MDS-B-SP, MDS-C1-SP, MDS-C1-SPA Series)
Capacity [kW] 0.4~3.7 5.5~18.5 22.0~30.0
37.0 45.0/55.0
P, N
(L+, L-)
Screw
Torque
[lb in/ N m]
L11, L21
(R0, S0)
Terminal
Screw
Size
Screw
Torque
[lb in/ N m]
U, V, W
Screw
Torque
[lb in/ N m]
P, N (L+, L-)
44.3/5.0 44.3/5.0
44.3/5.0 234.3/26.5
177/20
M4 M4 M4 M4 M4
17.4/2.0 17.4/2.0
17.4/2.0
17.4/2.0
17.2/2.0
M4 M5 M8 M8 M10
14.6/1.6 28.6/3.2 117.2/13.2 88.5/10.0
177/20
Wire size depends on the Power Supply Unit (MDS-B-CVE, MDS-C1-CV Series).
L11, L21 (R0, S0)
Capacity [kW]
Wire Size (AWG)
/Temp Rating Note 1
Crimping Terminals
Type
Crimping Tools Type
0.4~55.0
#14/60
°C
#14/75
°C
V2-4
YNT-1614
A8 - 7
Appendix 8. Instruction Manual for Compliance with UL/c-UL Standard
U, V, W
Capacity [kW] 0.4, 0.75
Wire Size (AWG)
1.5 2.2, 3.7
5.5
#14/60
°C #10/60°C #10/60°C
/Temp Rating
Note 1
#14/75
°C #14/75°C #12/75°C
7.5
#8/60
°C
#10/75
°C
Crimping
Terminals Type
Crimping Tools
Type
Earth Wire Size
(AWG)
R2-4
5.5-S4 R5.5-4
R2-4
R5.5-5
R8-5
R5.5-5
YHT-8S
YHT-2210
YHT-2210
#14/60
°C #11/60°C #10/60°C
#8/60
°C
#14/75
°C #14/75°C #10/75°C
#10/75
°C
11.0
#8/60
°C
#8/75
°C
R8-5
YHT-8S
#8/60
°C
#8/75
°C
15.0
#4/60
°C
#4/75
°C
L330T
459-23
YPT-60
#4 /60
°C
#4 /75
°C
Capacity [kW]
Wire Size (AWG)
/Temp Rating
Note 1
#3/60
°C #2/60°C #1/60°C
#4/75
°C #3/75°C #2/75°C
#1/75
°C
#1/0/75
°C
#2/0
75
°C
#4/0
/75
°C
Crimping
Terminals Type
22-S6
L330T
459-23
Crimping Tools
Type
Earth Wire Size
(AWG)
YPT-60
#3/60
°C #3/60°C
#4/75
°C #3/75°C
#3/75
°C
YET300
YF-1
#1/75
°C
YPT-150
#1/75
°C
#3/0
/75
°C
Note 1: 60
°C: Polyvinyl chloride insulated wires (IV)
75
°C: Grade heat-resistant polyvinyl chloride insulated wires (HIV)
Use copper wire only.
Above listed wire are for use in the electric cabinet on machine or equipment.
A8 - 8
Appendix 8. Instruction Manual for Compliance with UL/c-UL Standard
4.8 Spindle Drive / Motor Combinations
Following combinations are the Standard combinations
Rating Output (kW)
Of Applicable Spindle Motor
Drive Unit Note: 1
SJ- ( ) Series
SJ-V/VL Series
Note: 2
SJ-N Series
SJ-NL Series
MDS-B-SP []-04
MDS-C1-SP []-04
MDS-B-SP []-075
MDS-C1-SP []-075
MDS-B –SP []-15
MDS-C1-SP []-15
MDS-B –SP []-22
MDS-C1-SP []-22
MDS-B –SP []-37
MDS-C1-SP []-37
MDS-B-SP []-55
MDS-C1-SP []-55
MDS-C1-SPA []-55
MDS-B-SP []-75
MSD-C1-SP []-75
MDS-C1-SPA []-75
MDS-B-SP []-110
MDS-C1-SP []-110
MDS-C1-SPA []-110
MDS-B-SP []-150
MDS-C1-SP []-150
MDS-C1-SPA []-150
MDS-B-SP []-185
MDS-C1-SP []-185
MDS-C1-SPA []-185
0.2
0.75
1.5
2.2 2.2
3.7 3.7
5.5 5.5
5.5
7.5
7.5
11
MDS-B-SP []-220
MDS-C1-SP []-220
MDS-C1-SPA []-220
MDS-B-SP []-260
MDS-C1-SP []-260
MDS-C1-SPA []-260
MDS-B-SP []-300
MDS-C1-SP []-300
MDS-C1-SPA []-300
MDS-B-SP [] –370
MDS-B-SP [] -450
MDS-B-SP [] -550
11
15
18.5
11
15
18.5
22
5.5
7.5
11
7.5
11
15
11
15
18.5
22
26
15
18.5
22
26
30
15
18.5
22
26
30
37
22
26
30
37
45
30
37
45
55
Note1: [] can be H, M, X, HX, MX or none only SP.
[] can be H or none only SPA .
Note2: Applicable unit depends on the range of power constant of motor.
Inquire of Mitsubishi about the detail of the combinations.
A8 - 9
Appendix 8. Instruction Manual for Compliance with UL/c-UL Standard
5. AC Servo/Spindle System Connection
5-1 Use S Analog Drive Unit
Regarding the connection of NC, see the NC manual book.
MDS-C1-SP[H][M][X] Series
MDS-B-SP(H)(M)[X] Series
MDS-C1-CV Series
MDS-B-CVE Series
CN11 CN12
NC
PC
DIO
Metor
Personal-
computer
CN9A CN4
CN5 CN6
CN10 CN8A
CN4
CN9
External Emergency Stop
U/V/W
L+/L-
L11/L21
MC1
CN2 L1/L2/L3
MC
MC
Contactor
AC-L
AC Reactor
Circuit Breaker
Fuse or
Breaker
3 phase
200/220VAC
Enclosure Side
Machine Side
Spindle Motor
FAN
Encoder and
Thermal Protection
A8 - 10
Appendix 9. Compliance with China Compulsory
Product Certification (CCC Certification)
System
Appendix 9-1 Outline of China Compulsory Product Certification System ............................................A9-2
Appendix 9-2 First Catalogue of Products subject to Compulsory Product Certification.......................A9-2
Appendix 9-3 Precautions for Shipping Products...................................................................................A9-3
Appendix 9-4 Application for Exemption ................................................................................................A9-4
Appendix 9-5 Mitsubishi NC Product Subject to/Not Subject to CCC Certification................................A9-5
A9 - 1
Appendix 9. Compliance with China Compulsory Product Certification (CCC Certification) System
Appendix 9-1 Outline of China Compulsory Product Certification System
The Safety Certification enforced in China included the "CCIB Certification (certification system based on the "Law of the People’s Republic of China on Import and Export Commodity Inspection" and
"Regulations on Implementation of the Import Commodities Subject to the Safety and Quality Licensing
System" enforced by the State Administration of Import and Export Commodity Inspection (SACI) on import/export commodities, and the "CCEE Certification" (certification system based on "Product
Quality Certification Management Ordinance" set forth by the China Commission for Conformity
Certification of Electrical Equipment (CCEE) on commodities distributed through China.
CCIB Certification and CCEE Certification were merged when China joined WTO (November 2001), and were replaced by the "China Compulsory Product Certification" (hereinafter, CCC Certification) monitored by the State General Administration of Quality Supervision, Inspection and Quarantine
(AQSIQ) of the People's Republic of China.
The CCC Certification system was partially enforced from May 2002, and was fully enforced from May
2003. Target commodities which do not have CCC Certification cannot be imported to China or sold in
China. (Indication of the CCIB or CCEE mark has been eliminated from May 1, 2003.)
CCIB : China Commodity Inspection Bureau
CCEE : China Commission for Conformity Certification of Electrical Equipment
CCC : China Compulsory Certification
Appendix 9-2 First Catalogue of Products subject to Compulsory Product
Certification
The First Catalogue of Products subject to Compulsory Product Certification, covering 132 items (19 categories) based on the CCIB products (104 items), CCEE products (107 items) and CEMC products
(Compulsory EMC Certification products) was designated on December 3, 2001.
Class Product catalogue Class Product catalogue
1 Electric Wires and Cables (5 items)
2 Switches, Installation protective and connection devices (6 items)
3
Circuit-breakers (including RCCB, RCBO, MCB)
Low-voltage switchers
(disconnectors, switch-disconnectors, and fuse-combination devices.
5
6
Electric tools
Welding machines
(16 items)
(15 items)
Regulations
Certification Household and similar electrical appliances
(18 items)
8 Audio and video equipment (16 items)
(12 items) equipment
10 Lighting apparatus
12 Motor vehicles and Safety
Parts
(2 items)
11 Telecommunication (9 items) equipment
(4 items) Other protective equipment for circuits
(Current limiting devices, circuits protective devices, over current protective devices, thermal protectors, over load relays, low-voltage electromechanical contactors and motor starters)
Relays (36V < Voltage
≤ 1000V)
Other switches
(Switches for appliances, vacuum switches, pressure switches, proximity switches, foot switches, thermal sensitive switches, hydraulic switches, push-button switches, position limit switches, micro-gap switches, temperature sensitive switches, travel switches, change-over switches, auto-change-over switches, knife switches)
CNCA -01C -011: 2001
(Switch and Control
Equipment)
CNCA -01C -012: 2001
(Installation Protective
Equipment)
13
14
15
16
17
18
19
Tyres
Safety Glasses
Agricultural Machinery
Latex Products
Medical Devices
Fire Fighting Equipment
Detectors for Intruder Alarm
Systems
(3 items)
(1 item)
(1 item)
(7 items)
(3 items)
(1 item)
Other devices
(contactors, motor starters, indicator lights, auxiliary contact assemblies, master controllers, A.C. Semiconductor motor controllers and starters)
Earth leakage protectors
Fuses
Low-voltage switchgear
4 Small power motors (1 item)
CNCA-01C-010:2001
(Low-voltage switchgear)
CNCA-01C-013:2001
(Small power motors)
(Note)
(Note) When the servomotor or the spindle motor of which output is 1.1kW or less (at 1500 r/min) is used,
NC could have been considered as a small power motor. However, CQC (China Quality
Certification Center) judged it is not.
A9 - 2
Appendix 9. Compliance with China Compulsory Product Certification (CCC Certification) System
Appendix 9-3 Precautions for Shipping Products
As indicated in Appendix 9-2, NC products are not included in the First Catalogue of Products subject to
Compulsory Product Certification. However, the Customs Officer in China may judge that the product is subject to CCC Certification just based on the HS Code.
Note 2
NC cannot be imported if its HS code is used for the product subject to CCC Certification. Thus, the importer must apply for a "Certification of Exemption" with CNCA.
Note 3
Refer to Appendix 10-4.
Application for Exemption for details on applying for an exemption.
(Note 1) The First Catalogue of Products subject to Compulsory Product Certification (Target HS
Codes) can be confirmed at http://www.cqc.com.cn/Center/html/60gonggao.htm
.
(Note 2) HS Code: Internationally unified code (up to 6 digits) assigned to each product and used for customs.
(Note 3) CNCA: Certification and Accreditation Administration of People's Republic of China
(Management and monitoring of certification duties)
A9 - 3
Appendix 9. Compliance with China Compulsory Product Certification (CCC Certification) System
Appendix 9-4 Application for Exemption
Following "Announcement 8" issued by the Certification and Accreditation Administration of the
People's Republic of China (CNCA) in May 2002, a range of products for which application for CCC
Certification is not required or which are exempt from CCC marking has been approved for special circumstances in production, export and management activities.
An application must be submitted together with materials which prove that the corresponding product complies with the exemption conditions. Upon approval, a "Certification of Exemption" shall be issued.
<Range of products for which application is exempt>
Range of products not requiring application
(a) Items brought into China for the personal use by the foreign embassies, consulates, business agencies and visitors
(Excluding products purchased from Service Company for Exporters)
(b) Products presented on a government-to-government basis, presents
(c) Exhibition products (products not for sale)
(d) Special purpose products (e.g., for military use)
Products not requiring application for CCC Certification are not required to be CCC marked or certified.
Range of products for which application is exempted
(e) Products imported or manufactured for research and development and testing purposes
(f) Products shipped into China for integration into other equipment destined for 100% re-export to a destination outside of China
(g) Products for 100% export according to a foreign trade contract (Excluding when selling partially in
China or re-importing into China for sales)
(h) Components used for the evaluation of an imported product line
(i) The products imported or manufactured for the service (service and repairs) to the end-user. Or the spare parts for the service (service and repairs) of discontinued products.
(j) Products imported or manufactured for research and development, testing or measurements
(k) Other special situations
The following documents must be prepared to apply for an exemption of the "Import Commodity Safety and Quality License" and "CCC Certification".
(a) Relevant introduction and description of the company.
(b) The characteristics of the products to be exempted.
(c) The reason for exemption and its evidence (ex. customs handbook).
(d) The name, trademark, quantity, model and specification of the products to be exempted.
(Attach a detail listing of these items for a large quantity of products. When importing materials for processing and repair equipments, submit a list of the importing materials for each month and repair equipments.)
(e) Guarantee for the safety of the products; self-declaration to be responsible for the safety during the manufacturing and use.
(f) To be responsible for the authenticity and legitimacy of the submitted documents. Commitment to assist CNCA to investigate on the authenticity of the documents (When CNCA finds it necessary to investigate on the authenticity of the documents.)
(2) Business license of the company (Copy)
(3) Product compliance declaration
Indicate which standard’s requirements the products comply with or submit a test report (Copy is acceptable. The report can be prepared in a manufacturer’s laboratory either at home or overseas.)
(4) Import license (Only if an import license is needed for this product. Copy is acceptable.)
(5) Quota certificate (Only if a quota certificate is needed for this product. Copy is acceptable.)
(6) Commercial contract (Copy is acceptable.)
(7) If one of item (4), (5) or (6) cannot be provided, alternative documents, such as bill of lading, the invoice, and other evidential documents must be submitted.
A9 - 4
Appendix 9. Compliance with China Compulsory Product Certification (CCC Certification) System
Appendix 9-5 Mitsubishi NC Product Subject to/Not Subject to CCC Certification
The state whether or not Mitsubishi NC products are subject to the CCC Certification is indicated below, based on the "First Catalogue of Products subject to Compulsory Product Certification" issued by the
State General Administration of Quality Supervision, Inspection and Quarantine (AQSIQ) of the
People's Republic of China and the Certification and Accreditation Administration of the People's
Republic of China (CNCA) on July 1, 2002.
Model China HS Code (Note 1)
Judgment on whether or not subject to
CCC Certification
Power supply unit
Servo/spindle drive unit
Servo/spindle
85044090
85371010
85015100
85015200
–
Not subject to CCC Certification
Not subject to CCC Certification
NC Not subject to CCC Certification
Display unit – Not subject to CCC Certification
(Note 1) The China HS Code is determined by the customs officer when importing to China. The above HS Codes are set based on the HS Codes used normally when exporting from Japan.
(Note 2) Reference IEC Standards are used as the actual IEC Standards may not match the GB
Standards in part depending on the model.
Whether or not the NC products are subject to CCC Certification was judged based on the following five items.
(a) Announcement 33 (Issued by AQSIQ and CNCA in December 2001)
(b) HS Codes for the products subject to CCC Certification (Export Customs Codes)
* HS Codes are supplementary materials used to determine the applicable range. The applicable range may not be determined only by these HS Codes.
(c) GB Standards (This is based on the IEC Conformity, so check the IEC. Note that some parts are deviated.)
(d) Enforcement regulations, and products specified in applicable range of applicable standards within
(e) "Products Excluded from Compulsory Certification Catalogue" (Issued by CNCA, November 2003)
Reference
• Outline of China's New Certification System (CCC Mark for Electric Products), Japan Electrical
Manufacturers' Association
• Outline of China's New Certification System (CCC Mark for Electric Products) and Electric
Control Equipment, Nippon Electric Control Equipment Industries Association
A9 - 5
Date of revision
Nov. 2005
Revision History
Revision details Manual No.
IB(NA)1500150-A First edition created.
Global service network
NORTH AMERICA FA Center
EUROPEAN FA Center
CHINA FA Center
KOREAN FA Center
North America FA Center (MITSUBISHI ELECTRIC AUTOMATION INC.)
Illinois CNC Service Center
500 CORPORATE WOODS PARKWAY, VERNON HILLS, IL. 60061, U.S.A.
TEL: +1-847-478-2500 (Se
California CNC Service Center
FAX: +1-847-478-2650 (Se
5665 PLAZA DRIVE, CYPRESS, CA. 90630, U.S.A.
TEL: +1-714-220-4796 FAX: +1-714-229-3818
Georgia CNC Service Center
2810 PREMIERE PARKWAY SUITE 400, DULUTH, GA., 30097, U.S.A.
TEL: +1-678-258-4500 FAX: +1-678-258-4519
New Jersey CNC Service Center
200 COTTONTAIL LANE SOMERSET, NJ. 08873, U.S.A.
TEL: +1-732-560-4500 FAX: +1-732-560-4531
Kentucky CNC Service Satellite
8025 PRODUCTION DRIVE, FLORENCE, KY., 41042, U.S.A.
TEL: +1-859-342-1700 FAX: +1-859-342-1578
Michigan CNC Service Satellite
2545 38TH STREET, ALLEGAN, MI., 49010, U.S.A.
TEL: +1-847-478-2500 FAX: +1-269-673-4092
Ohio CNC Service Satellite
62 W. 500 S., ANDERSON, IN., 46013, U.S.A.
TEL: +1-847-478-2608
Texas CNC Service Satellite
FAX: +1-847-478-2690
1000, NOLEN DRIVE SUITE 200, GRAPEVINE, TX. 76051, U.S.A.
TEL: +1-817-251-7468
Canada CNC Service Center
FAX: +1-817-416-1439
4299 14TH AVENUE MARKHAM, ON. L3R OJ2, CANADA
TEL: +1-905-475-7728
Mexico CNC Service Center
FAX: +1-905-475-7935
MARIANO ESCOBEDO 69 TLALNEPANTLA, 54030 EDO. DE MEXICO
TEL: +52-55-9171-7662 FAX: +52-55-9171-7698
Monterrey CNC Service Satellite
ARGENTINA 3900, FRACC. LAS TORRES, MONTERREY, N.L., 64720, MEXICO
TEL: +52-81-8365-4171 FAX: +52-81-8365-4171
Brazil MITSUBISHI CNC Agent Service Center
(AUTOMOTION IND. COM. IMP. E EXP. LTDA.)
ACESSO JOSE SARTORELLI, KM 2.1 18550-000 BOITUVA – SP, BRAZIL
TEL: +55-15-3363-9900 FAX: +55-15-3363-9911
European FA Center (MITSUBISHI ELECTRIC EUROPE B.V.)
Germany CNC Service Center
GOTHAER STRASSE 8, 40880 RATINGEN, GERMANY
TEL: +49-2102-486-0 FAX:+49-2102486-591
South Germany CNC Service Center
KURZE STRASSE. 40, 70794 FILDERSTADT-BONLANDEN, GERMANY
TEL: +49-711-3270-010 FAX: +49-711-3270-0141
France CNC Service Center
25, BOULEVARD DES BOUVETS, 92741 NANTERRE CEDEX FRANCE
TEL: +33-1-41-02-83-13 FAX: +33-1-49-01-07-25
Lyon CNC Service Satellite
U.K CNC Service Center
TRAVELLERS LANE, HATFIELD, HERTFORDSHIRE, AL10 8XB, U.K.
TEL: +44-1707-282-846 FAX:-44-1707-278-992
Italy CNC Service Center
ZONA INDUSTRIALE VIA ARCHIMEDE 35 20041 AGRATE BRIANZA, MILANO ITALY
TEL: +39-039-60531-342 FAX: +39-039-6053-206
Spain CNC Service Satellite
CTRA. DE RUBI, 76-80 -APDO.420 08190 SAINT CUGAT DEL VALLES, BARCELONA SPAIN
TEL: +34-935-65-2236 FAX:
Turkey MITSUBISHI CNC Agent Service Center
(GENEL TEKNIK SISTEMLER LTD. STI.)
DARULACEZE CAD. FAMAS IS MERKEZI A BLOCK NO.43 KAT2 80270 OKMEYDANI ISTANBUL,
TURKEY
TEL: +90-212-320-1640 FAX: +90-212-320-1649
Poland MITSUBISHI CNC Agent Service Center (MPL Technology Sp. z. o. o)
UL SLICZNA 34, 31-444 KRAKOW, POLAND
TEL: +48-12-632-28-85 FAX:
Wroclaw MITSUBISHI CNC Agent Service Satellite (MPL Technology Sp. z. o. o)
UL KOBIERZYCKA 23, 52-315 WROCLAW, POLAND
TEL: +48-71-333-77-53 FAX: +48-71-333-77-53
Czech MITSUBISHI CNC Agent Service Center
(AUTOCONT CONTROL SYSTEM S.R.O. )
NEMOCNICNI 12, 702 00 OSTRAVA 2 CZECH REPUBLIC
TEL: +420-596-152-426 FAX: +420-596-152-112
ASEAN FA Center
HONG KONG FA Center
TAIWAN FA Center
ASEAN FA Center (MITSUBISHI ELECTRIC ASIA PTE. LTD.)
Singapore CNC Service Center
307 ALEXANDRA ROAD #05-01/02 MITSUBISHI ELECTRIC BUILDING SINGAPORE 159943
TEL: +65-6473-2308 FAX: +65-6476-7439
Thailand MITSUBISHI CNC Agent Service Center (F. A. TECH CO., LTD)
898/19,20,21,22 S.V. CITY BUILDING OFFICE TOWER 1 FLOOR 12,14 RAMA III RD BANGPONGPANG,
YANNAWA, BANGKOK 10120. THAILAND
TEL: +66-2-682-6522 FAX: +66-2-682-6020
Malaysia MITSUBISHI CNC Agent Service Center
(FLEXIBLE AUTOMATION SYSTEM SDN. BHD.)
60, JALAN USJ 10/1B 47620 UEP SUBANG JAYA SELANGOR DARUL EHSAN MALAYSIA
TEL: +60-3-5631-7605 FAX: +60-3-5631-7636
JOHOR MITSUBISHI CNC Agent Service Satellite
(FLEXIBLE AUTOMATION SYSTEM SDN. BHD.)
NO. 16, JALAN SHAHBANDAR 1, TAMAN UNGKU TUN AMINAH, 81300 SKUDAI, JOHOR MALAYSIA
TEL: +60-7-557-8218 FAX: +60-7-557-3404
Indonesia MITSUBISHI CNC Agent Service Center
(PT. AUTOTEKNINDO SUMBER MAKMUR)
WISMA NUSANTARA 14TH FLOOR JL. M.H. THAMRIN 59, JAKARTA 10350 INDONESIA
TEL: +62-21-3917-144 FAX: +62-21-3917-164
India MITSUBISHI CNC Agent Service Center (MESSUNG SALES & SERVICES PVT. LTD.)
B-36FF, PAVANA INDUSTRIAL PREMISES M.I.D.C., BHOASRI PUNE 411026, INDIA
TEL: +91-20-2711-9484 FAX: +91-20-2712-8115
BANGALORE MITSUBISHI CNC Agent Service Satellite
(MESSUNG SALES & SERVICES PVT. LTD.)
S 615, 6TH FLOOR, MANIPAL CENTER, BANGALORE 560001, INDIA
TEL: +91-80-509-2119 FAX: +91-80-532-0480
Delhi MITSUBISHI CNC Agent Parts Center (MESSUNG SALES & SERVICES PVT. LTD.)
1197, SECTOR 15 PART-2, OFF DELHI-JAIPUR HIGHWAY BEHIND 32ND MILESTONE GURGAON
122001, INDIA
TEL: +91-98-1024-8895 FAX:
Philippines MITSUBISHI CNC Agent Service Center
(FLEXIBLE AUTOMATION SYSTEM CORPORATION)
UNIT No.411, ALABAMG CORPORATE CENTER KM 25. WEST SERVICE ROAD SOUTH
SUPERHIGHWAY, ALABAMG MUNTINLUPA METRO MANILA, PHILIPPINES 1771
TEL: +63-2-807-2416 FAX: +63-2-807-2417
Vietnam MITSUBISHI CNC Agent Service Center (SA GIANG TECHNO CO., LTD)
47-49 HOANG SA ST. DAKAO WARD, DIST.1 HO CHI MINH CITY, VIETNAM
TEL: +84-8-910-4763 FAX: +84-8-910-2593
China FA Center (MITSUBISHI ELECTRIC AUTOMATION (SHANGHAI) LTD.)
China CNC Service Center
2/F., BLOCK 5 BLDG.AUTOMATION INSTRUMENTATION PLAZA, 103 CAOBAO RD. SHANGHAI
200233, CHINA
TEL: +86-21-6120-0808
Shenyang CNC Service Center
TEL: +86-24-2397-0184
Beijing CNC Service Satellite
FAX: +86-21-6494-0178
FAX: +86-24-2397-0185
9/F, OFFICE TOWER1, HENDERSON CENTER, 18 JIANGUOMENNEI DAJIE, DONGCHENG DISTRICT,
BEIJING 100005, CHINA
TEL: +86-10-6518-8830 FAX: +86-10-6518-8030
China MITSUBISHI CNC Agent Service Center
(BEIJING JIAYOU HIGHTECH TECHNOLOGY DEVELOPMENT CO.)
RM 709, HIGH TECHNOLOGY BUILDING NO.229 NORTH SI HUAN ZHONG ROAD, HAIDIAN DISTRICT ,
BEIJING 100083, CHINA
TEL: +86-10-8288-3030
Tianjin CNC Service Satellite
FAX: +86-10-6518-8030
RM909, TAIHONG TOWER, NO220 SHIZILIN STREET, HEBEI DISTRICT, TIANJIN, CHINA 300143
TEL: -86-22-2653-9090 FAX: +86-22-2635-9050
Shenzhen CNC Service Satellite
RM02, UNIT A, 13/F, TIANAN NATIONAL TOWER, RENMING SOUTH ROAD, SHENZHEN, CHINA 518005
TEL: +86-755-2515-6691 FAX: +86-755-8218-4776
Changchun Service Satellite
TEL: +86-431-50214546
Hong Kong CNC Service Center
TEL: +852-2619-8588
FAX: +86-431-5021690
UNIT A, 25/F RYODEN INDUSTRIAL CENTRE, 26-38 TA CHUEN PING STREET, KWAI CHUNG, NEW
TERRITORIES, HONG KONG
FAX: +852-2784-1323
Taiwan FA Center (MITSUBISHI ELECTRIC TAIWAN CO., LTD.)
Taichung CNC Service Center
NO.8-1, GONG YEH 16TH RD., TAICHUNG INDUSTIAL PARK TAICHUNG CITY, TAIWAN R.O.C.
TEL: +886-4-2359-0688
Taipei CNC Service Satellite
FAX: +886-4-2359-0689
FAX: +886-4-2359-0689 TEL: +886-4-2359-0688
Tainan CNC Service Satellite
TEL: +886-4-2359-0688 FAX: +886-4-2359-0689
Korean FA Center (MITSUBISHI ELECTRIC AUTOMATION KOREA CO., LTD.)
Korea CNC Service Center
DONGSEO GAME CHANNEL BLDG. 2F. 660-11, DEUNGCHON-DONG KANGSEO-KU SEOUL, 157-030
KOREA
TEL: +82-2-3660-9607 FAX: +82-2-3663-0475
Notice
Every effort has been made to keep up with software and hardware revisions in the contents described in this manual. However, please understand that in some unavoidable cases simultaneous revision is not possible.
Please contact your Mitsubishi Electric dealer with any questions or comments regarding the use of this product.
Duplication Prohibited
This instruction manual may not be reproduced in any form, in part or in whole, without written permission from Mitsubishi Electric Corporation.
© 2004-2005 MITSUBISHI ELECTRIC CORPORATION
ALL RIGHTS RESERVED
Download
Advertisement
Key features
Advanced control algorithms for precise motor control
Built-in PLC for flexible motion control
EtherCAT connectivity for high-speed communication
Compact design for space-saving installation
Rugged construction for harsh industrial environments
Easy-to-use programming interface
Comprehensive safety features
Frequently asked questions
The SPA150.4 has a rated output power of 150 kW and a maximum output current of 400 A.
The SPA150.4 can control both AC servo motors and spindle motors.
Yes, the SPA150.4 supports both incremental and absolute encoders.