advertisement
Structural Monitoring
Equipment List
2
Overview
GeoMoS Modules
GeoMoS Maintenance
Monitoring Systems
Sensors
3
Power Supply
Cables
For transmitting data
Accessories
Third party
4
GeoMoS Modules
GeoMoS – Geodetic and geotechnical Monitoring Solutions
GeoMoS comprises the following modules:
Leica GeoMoS User Versions
Demo
Version
(1 year)
Article Name
Article Number (SAP)
CD-ROM included
USB Dongle (default)
Parallel Dongle (optional)
Sensor License
Monitor Option 1 (Computation)
Monitor Option 2 (Limit checks/Messaging)
Monitor Option 3 (Export Service for
GeoMoS Adjustment)
Analyzer Option 1 (TPS Post-Processing)
Quarterly Subscription Per Point
Administration Fee
723 367
734 713
734 712
758 750
758 751
758 752
773 056
758 753
5 302 475
5 001 893
758 749 723 366 5001892 772 767 724 933 z z ─ z z z z ─ z z
}
}
}
}
}
─
─
─
─
─
─
─
}
─
─
─
} z z z
} z
─
─
─
─
}
─
─
─
─ z z
─
─
─
─ z
─
─
Legend z
}
─ included: automatically, not removable optional not available
Software protection keys
734 712
734 713
Upgrade
748 840
CCP
Software protection key (parallel)
Software protection key (USB)
Upgrade from GeoMoS Version 1.55, 1.6, 2.0 and 2.1 to Version 5.0 (inclusive Upgrade from existing GeoMoS Options to new GeoMoS 5.0 Options).
Upgrade from GeoMoS Version 3.0, 3.1, 4.0, 4.1 to Version 5.0 (inclusive Upgrade from all Options).
5
1.1 GeoMoS Monitor (758 749)
GeoMoS Monitor is the monitoring software for the normal use of the customer. The customer can collect and store data.
Additional options can be added later.
Connection to sensors (serial or TCP/IP) with valid Sensor Licenses
Project management
User levels
Learn points
Manual stand point coordinate determination with Free Station,
Distance Intersection or GNSS Update
Automatic measurements with various options
Blunder tolerance checks on raw data
Information about the current system and measurement status
Calculation of GNSS displacements and daily average results
Automatic database export
SQL Server 2005 Express database included
A number of options are available for the use together with GeoMoS Monitor:
758 751
758 752
773 056
GeoMoS Monitor Option 1 (Computation)
GeoMoS Monitor Option 2 (Limit checks and Messaging)
GeoMoS Monitor Option 3 (Export Service to GeoMoS Adjustment)
Note: Sensors can only connected to GeoMoS Monitor, if the required amount of sensor licenses has been ordered
also. Refer to the section “ 1.2 Sensor License
” for more detail.
Leica GeoMoS makes use of the Microsoft SQL database. With Leica GeoMoS the free version Microsoft SQL Server 2005 Express is provided and will be installed, if no SQL server is available.
1.1.1 GeoMoS Monitor Option 1 (758 751)
Computation Automatic total station stand point setup with different methods (Free
Station, Distance Intersection or GNSS Update)
Calculation of any total station results including coordinates, displacements, profiles, distance reduction
Calculation of any total station correction with Free Station, Distance
Intersection, Orientation, PPM and Vz Correction groups and associated point group properties
Calculation of daily average results for total stations
Computation of virtual sensors with constants, mathematical functions and/or logic operators.
1.1.2 GeoMoS Monitor Option 2 (758 752)
Limit checks and Messaging Automatic computation of limit checks
Multiple levels of limit checks (yellow, orange, red)
Limit Level 1, 2 and 3 can be assigned independent actions
Four different types of limit check computation (absolute, short time, long time and regression)
Allows emails and SMS to be sent, applications to be run, the database to be queried and digital outputs to be set when defined messages are generated by the system
1.1.3 GeoMoS Monitor Option 3 (773 056)
Export Service for GeoMoS Manual and automatic GeoMoS data export in XML format
Adjustment
6
1.2 Sensor License (758 750)
The sensor license concept means that the software scales with the number and type of sensors you have connected. Additional sensor licenses can easily be added later should your needs change.
For each sensor you need to order a special amount of Sensor Licenses (Art. No. 758 750). The required amount of sensor licenses per sensor is listed below:
* Sensor License
Amount required per sensor
TPS Sensor 30
10 GNSS Sensor (NMEA)
Connection to a GNSS Spider Site Server with all
Spider RT Positioning Products
Connection to a GNSS Spider Site Server with all
Spider PP Positioning Products
Nivel200 Sensor
Digital Level
10
10
3
3
Temperature / Pressure Sensor (DTM STS) 1
Geotechnical Sensor connected via Campbell
Scientific Datalogger
1
Note that each sensor requires sensor licenses even though the sensor is connected with a bus system (Nivel220) or Campbell
Scientific datalogger (geotechnical sensor) to GeoMoS.
For more information about connectable sensors offering with GeoMoS Monitor please contact your local Leica Geosystems organization or distribution partner.
1.2.1 Sensor Licenses – Examples
Example 1:
Your customer wants to use a total station and a temperature sensor for monitoring with GeoMoS.
How many Sensor Licenses must he order?
1x TPS Sensor
1x Temperature Sensor (DTM STS)
30
01
Sensor Licenses (Art. No. 758 750) 31
Example 2:
Your customer wants to use a Nivel220 bus system with five sensors for monitoring with GeoMoS.
How many Sensor Licenses must he order?
5x Nivel200 Sensor
Sensor Licenses (Art. No. 758 750)
1x TPS Sensor
1x Connection to a GNSS Spider Site Server with all Spider RT
Positioning Products
5 x 3
15
Example 3:
Your customer wants to use a combined TPS/GNSS monitoring system with a total station and GNSS Spider RT positioning products for monitoring with GeoMoS. Therefore five GNSS sensors are connected as passive LB2 and two GNSS sensors as active data streams to GNSS Spider.
How many Sensor Licenses must he order?
30
10
Sensor Licenses (Art. No. 758 750) 40
Note: The Spider RT Positioning Products computation requires additional Spider Positioning Site Licenses (Art. No. 744 912).
Refer to “ 4.2.4 GNSS Spider ”.
7
Example 4:
Your customer wants to use a combined TPS/GNSS monitoring system with a total station and GNSS Spider RT and PP positioning products for monitoring with GeoMoS. The customer has 12 GNSS sensors are connected to GNSS Spider.
How many Sensor Licenses must he order?
1x TPS Sensor
1x Connection to a GNSS Spider Site Server with all Spider RT
Positioning Products
1x Connection to a GNSS Spider Site Server with all Spider PP
Positioning Products
30
10
10
Sensor Licenses (Art. No. 758 750) 50
Note: The Spider RT and PP Positioning Products computation requires additional Spider Positioning Site Licenses (Art. No. 744
912) and Spider File Products Service (FPS) option (Art. No. 744 904). Refer to “ 4.2.4 GNSS Spider
”.
Example 5:
Your customer wants to use a Campbell Scientific Datalogger with different geotechnical sensors for monitoring with GeoMoS.
How many Sensor Licenses must he order?
Setup A 1 sensor measuring one value type (e.g. wind speed)
Setup B 1 sensor measuring three value types (e.g. temperature, pressure and humidity)
Setup C 1 sensor measuring one value type (e.g. wind speed) and 1 sensor measuring one value type (e.g. rain fall)
Setup D 5 sensors measuring three value types (e.g. temperature, pressure and humidity)
01
03
02
15
1.3 GeoMoS Analyzer (723 366)
GeoMoS Analyzer is an analysis tool that can be used to view data collected by any GeoMoS Monitor.
Note: For online analysis using GeoMoS Analyzer at a remote location there needs to be continual connection between GeoMoS
Monitor and GeoMoS Analyzer computers.
Graphical and numerical visualization of results
More than one installation of Analyzer may access the data and do analysis simultaneously
Project management
User levels
Outlier detection algorithm
Set results invalid/valid
Enter comments
Customizable graphics
Customizable reports with filter and search mechanism
Manual database import and export
Export to other systems e.g. ASCII, DXF and BMP
SQL Server 2005 Express database included
A number of options are available for use together with GeoMoS Analyzer:
758 753 GeoMoS Analyzer Option 1 (TPS Post-Processing)
Leica GeoMoS makes use of the Microsoft SQL database. With Leica GeoMoS the free version Microsoft SQL Server 2005 Express is provided and will be installed, if no SQL server is available.
1.3.2 GeoMoS Analyzer Option 1 (758 753)
TPS post processing Re-processing of the coordinate system, distance reduction, meteo model and all values modified in the Data Editor
Data Editor to modify additive constants, reflector heights, temperature and pressure
Re-processing of the profile directions, instrument height and null coordinate together with GeoMoS Monitor
8
1.4 GeoMoS Demo (724 933)
GeoMoS Demo is only for demonstration purposes to sell the product. GeoMoS Demo is not for commercial sale. GeoMoS Demo has the same functionality as GeoMoS Monitor and GeoMoS Analyzer but cannot be used for permanent monitoring. The automatic measurement will only run for a limited time (TPS Sensor measurements = 100, geotechnical measurements = 500).
Note: GeoMoS Demo does not include Leica GeoMoS Adjustment and GeoMoS Monitor Option 3
1.5 GeoMoS Web (5 001 892)
Leica GeoMoS Web is a web based service for visualization and analysis of monitoring data collected by GeoMoS Monitor.
Easy access through standard web browsers
Graphical and visualization of monitoring data
Overview and site maps
Timeline, scatter and vector graphs
View webcam images and web image
User levels (admin, viewer)
Customizable graphics
Save raw data to comma separated files
Personalized and secure data access
No need to maintain IT infrastructure and software
Physical and electronic security of data
Protection against misusage
Easy translation based on XML files
The Leica GeoMoS Web service is composed of:
an one time only Setup Fee (Art. No. 5 001 892) and
a quarterly Subscription (Art. No. 5 302 475) that scales with the size of the monitoring installation.
Leica GeoMoS Web
5 001 892 GeoMoS Web Setup Fee For the initial configuration of the service. Once only.
5 302 475
GeoMoS Web Quarterly
Subscription Per Point
For access to the web service for a period of three months
(90 days). One article is required for each monitoring point to be shown in the web. A minimum of 5 X Article 5 302 475 is required.
Billing
An invoice will be sent each month or quarter for the amount of Quarterly Subscription Per Point’s that were ordered.
The service is paid per billing period (month / quarter).
Service Change Requests
The amount of Quarterly Subscription Per Point’s of the Leica GeoMoS Web service can be changed at a month’s notice for the next billing period. An administration fee (Article 5 001 893) of 200.- CHF is incurred each time the number of points is increased. It is not possible to decrease the number of points.
Cancellation
The Leica GeoMoS Web service can be cancelled with a month’s notice for the next billing period.
The cancellation notice must be given in written form.
Customer Care Package License
Leica GeoMoS Web is a service that requires no extra CCP License.
9
1.6 GeoMoS Adjustment (772 767)
Leica GeoMoS Adjustment is an add-on analysis software that can be used to compute network adjustment and deformation analysis data collected by any GeoMoS Monitor.
Manual and automatic import of GeoMoS XML files
Network adjustment computation as minimal constraint network, reference points as fixed or absolute fixed
Automatic outlier detection and removal
Deformation analysis based on the two-step method
Detect stable and unstable reference points
Combination of total stations and/or GPS/GNSS
Numerical and graphical analysis of the network adjustment and deformation analysis data
Statistically qualified data with precision and reliability
Display the magnitude, precision pattern and statistically significance of movements
Display unstable reference points
Compare the results of different measurement epochs
Simulate the mathematical geometry simulation to optimize the network accuracy and reliability
Extended Analysis Service
Consultation, training and data analysis services are available from our partner company
Technet GmbH. Technet’s highly qualified engineers have over 15 years of experience in high precision deformation surveys, network adjustment and deformation analysis in a wide range of projects.
Notes:
GeoMoS Monitor Option 3 (773 056) is required to export data for GeoMoS Adjustment. The GeoMoS Monitor Option 3 bit must be available on the dongle where GeoMoS Monitor is running.
GeoMoS Demo (724 933) does not include Leica GeoMoS Adjustment
1.7 Leica CrossCheck
Leica CrossCheck is a web based service for GPS/GNSS reference network coordinate calculation, integrity monitoring and deformation monitoring.
Monitoring Service
The Monitoring Service provides detection and warning of antenna movements in near real time for networks of
GNSS reference stations or monitoring receivers. Site coordinates are calculated at a user defined interval. The solution is tailored to the needs of the customers network/project, including the processing interval, processing strategy, coordinate datum, limit checks and content of the secure online web service. An email messaging service is offered to provide warning when a significant movement occurs.
The Monitoring Service consists of a one-time setup fee and then a quarterly subscription comprised of a base fee and a per site fee.
Leica GeoMoS CrossCheck for monitoring
5 002 094
5 302 771
5 302 772
CrossCheck Monitoring
Setup Fee
CrossCheck Quarterly
Subscription Base Fee
CrossCheck Quarterly
Subscription Per Site
For the initial configuration of the service. Once only.
For access to the web service for a period of three months
(90 days). One article is required for each web service.
For access to the web service for a period of three months
(90 days). One article is required for each monitoring receiver.
10
Invoicing
The initial setup fee will be invoiced after sending the entitlement number (see below)
The Single Computation Service will be invoiced once the service has been completed
The Monitoring Service will be invoiced quarterly at the end of the period, if not cancelled (see below)
Monitoring Service Change Requests
The amount of Quarterly Subscription Per Site of the Leica CrossCheck Monitoring Service can be changed at a month’s notice for the next billing period. An administration fee (Article 5 002 120) is incurred each time the number of points is increased or decreased.
Cancellation
The Leica CrossCheck Monitoring Service can be cancelled with a month’s notice for the next quarter.
The cancellation notice must be given in written form.
11
GeoMoS Maintenance
2.1 Customer Care Packages (CCP)
A powerful and competent worldwide service and support network backs up Leica GeoMoS.
Leica GeoMoS Monitor
Leica GeoMoS Analyzer
Leica GeoMoS Adjustment
Customer Care Packages (CCPs) provide you access to a world-class support & service infrastructure and ensure your systems are being kept up to date.
A wide selection of comprehensive Customer Care Packages is available bundling Hardware
Maintenance, Software Maintenance, Customer Support and Extended Warranty. For more information about the CCP offering in your country please contact your local Leica Geosystems organization or distribution partner.
The Customer Care Packages articles are available worldwide and can be ordered for end-users together with new software.
Select CCP
6000933
6000934
6000935
1 year GeoMoS Basic CCP
2 year GeoMoS Basic CCP
3 year GeoMoS Basic CCP
Select CCP for Distribution Partner
6000936
6000937
6000938
1 year GeoMoS Distr. Basic CCP
2 year GeoMoS Distr. Basic CCP
3 year GeoMoS Distr. Basic CCP
2.2 Other Services
The following services are available on request at daily rates.
Training at customer site
Customizing
Information on article numbers are available on request.
12
Monitoring systems
3.1 Overview
Each monitoring project has specific measurement and accuracy requirements. If you are going to prepare a monitoring project or plan to offer a quotation for a monitoring tender, the following five sections have to considered:
1. Sensors
Total stations, prisms and mounting
GNSS Sensors, antennas and mounting
Inclination Sensors, shelters and mounting
Meteo Sensors, mounting
Other Sensors
2. PC and Software
3. Power
4. Communication
5. Miscellaneous
Robust PC with serial ports and GeoMoS, GeoMoS Web, GNSS Spider or GNSS QC.
Reliable power source with backup
direct power or
separate units or
solar panels
Cables, radio modems
Measurement hut to protect the total station and PC from the elements for example rain, sun, dust, snow
Pillars and monumentation
Climate control system (avoid temperature expansion, moisture, condensation and uneven heating of the instrument)
Security
Access (physical and remote)
Combine Leica software, geodetic, geotechnical and meteorological sensors to match the needs of your monitoring challenge.
Basic examples are given in the next section to provide an idea of monitoring setups and options.
13
GeoMoS is an integrated solution that supports total station, GNSS receivers, levels and geotechnical sensors for an overall understanding of structural movements.
In large monitoring projects total stations and GNSS receivers can be combined in many different ways to match the requirements and use a stable reference. The diagram below shows various possibilities.
Δ
Δ
2
Δ
Legend ▲
●
Stable reference point
Unstable monitoring point
Δ H, Δ X, Δ Y Offsets to be set in GeoMoS
Total station with co-located GNSS sensor
A GNSS antenna can be mounted on the top of the measurement hut and applied to the total station stand point with a three-dimensional offset.
To orientate the system, a GNSS antenna inside the unstable area is used to update the reference point.
The GNSS antenna needs a reference station so that baselines can be computed.
Reference points with co-located GNSS sensors
A total station stand point can be measured and calculated with a free station or distance intersection to reference points inside the unstable area.
A GNSS antenna can be mounted on the top of the prism and applied to the point with a height offset.
The GNSS antenna needs a reference station so that baselines can be computed.
Reference station
A GNSS antenna can be mounted in a stable area as a reference station. The reference station should be as close as possible (<3km) to the monitoring area so that the baselines can be computed with the highest accuracy.
14
3.2 Setup of a Total Station with direct serial
734 698
759 257
439 038
749 279
744 793
772 630
664 662
757 129
764 824
Select Total Station
664 662
757 129
764 824
TCA2003, 0.5"(0.15mgon) automatic precision total station, with laser plummet, 2 control panels, accessories, user manual and container.
TM30 0.5”, 0.15gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.
TM30 1”, 0.3gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.
Select Cables and Switchbox
744 793
772 630
734 698
Switchbox with cable 2.0m for TPS/1000/1100/1200 and GeoMoS. Supports cold boot for TPS
(important 24/7 hours/day monitoring).
GDZ 68, Switchbox with a 2.0m cable for TM30/TS30 (Lemo 1) and GeoMoS. Supports cold boot for
TPS (important 24/7 hours/day monitoring).
GEV187, Y-cable, connects TPS/1000/1100/1200 to PC (9-pin RS232 serial) and external battery, 2.0m.
GEV220, Y-cable, connects TM30/TS30 to PC (9-pin RS232 serial) and external battery, 2.0m. 759 257
Select Power
439 038
749 279 cable with 5-pin Lemo to connect to TPS.
Select power cords for 12V power supply unit 749 279. Refer to “
Select Software
GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.
GEV208, Power supply unit for TPS, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD,
GeoMoS Monitor / Analyzer
”
15
3.3 Remote Setup of a Total Station with Radio (GFU14)
639 964
667 243
733 275, 733 276,
738 272, 738 273,
738 274, 738 275,
738 276 733 297
639 964
667 243
733 275, 733 276,
738 272, 738 273,
738 274, 738 275,
738 276
733 297
439 038
749 279 439 038
Mini Adapter
734 698
759 257
664 662
757 129
764 824
439 038
749 279
749 279
744 793
772 630
Select Total Station
664 662
757 129
764 824
TCA2003, 0.5"(0.15mgon) automatic precision total station, with laser plummet, 2 control panels, accessories, user manual and container.
TM30 0.5”, 0.15gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.
TM30 1”, 0.3gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.
Select Cables and Switchbox
744 793
772 630
734 698
759 257
733 297
Mini adapter
Switchbox with cable 2.0m for TPS/1000/1100/1200 and GeoMoS. Supports cold boot for TPS
(important 24/7 hours/day monitoring)
GDZ 68, Switchbox with a 2.0m cable for TM30/TS30 (Lemo 1) and GeoMoS. Supports cold boot for
TPS (important 24/7 hours/day monitoring).
GEV187, Y-cable, connects TPS/1000/1100/1200 to PC (9-pin RS232 serial) and external battery, 2.0m.
GEV220, Y-cable, connects TM30/TS30 to PC (9-pin RS232 serial) and external battery, 2.0m.
GEV171, 1.8m cable to program, the Satelline 3AS radio modem inside the GFU14 housing.
Null modem, DB9 male to DB9 male. Refer to “
”.
Select Radio Modem
733 275
733 276
738 272
738 273
738 274
738 275
738 276
GFU14-0, Satelline 3AS radio modem (433.525 MHz, 25.0 kHz channel spacing, 0.5 W)
GFU14-1, Satelline 3AS radio modem (406.425 MHz, 25.0 kHz channel spacing, 1.0 W)
GFU14-2, Satelline 3AS radio modem (445.000 MHz, 12.5 kHz channel spacing, 1.0 W)
GFU14-3, Satelline 3AS radio modem (443.000 MHz, 12.5 kHz channel spacing, 1.0 W)
GFU14-4, Satelline 3AS radio modem (440.550 MHz, 25.0 kHz channel spacing, 0.5 W)
GFU14-5, Satelline 3AS radio modem (458.150 MHz, 12.5 kHz channel spacing, 0.5 W)
GFU14-6, Satelline 3AS radio modem (439.8625 MHz, 12.5 kHz channel spacing, 1.0 W)
16
Select Radio Antenna
639 964 GAT1, Gainflex radio antenna, frequency range 400-435MHz.
GAT2, Gainflex radio antenna, frequency range 435-470MHz. 667 243
Select Power
439 038
749 279
GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.
GEV208, Power supply unit for TPS, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to TPS.
Select power cords for 12V power supply unit 749 279. Refer to “
Select Software
GeoMoS Monitor / Analyzer
”
17
3.4 Remote Setup of a Total Station with Radio (TCPS27)
734161
734162
734 699
734 697
771 057 664 662
757 129
764 824
439 038
439 038
749 279
749 279
744 793
772 630
Select Total Station
664 662
757 129
764 824
TCA2003, 0.5"(0.15mgon) automatic precision total station, with laser plummet, 2 control panels, accessories, user manual and container.
TM30 0.5”, 0.15gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.
TM30 1”, 0.3gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.
Select cables and switchbox
744 793
772 630
734 697
771 057
Switchbox with cable 2.0m for TPS/1000/1100/1200 and GeoMoS. Supports cold boot for TPS
(important 24/7 hours/day monitoring)
GDZ 68, Switchbox with a 2.0m cable for TM30/TS30 (Lemo 1) and GeoMoS. Supports cold boot for
TPS (important 24/7 hours/day monitoring).
GEV186, Y-cable, connects TCPS27 to TPS/1000/1100/1200 and external battery, 1.8m.
GEV236, Y-cable, connects TM30/TS30 to TCPS radio and external battery, 2m.
734 699
Select Radio Modem
GEV188, Y-cable, connects TCPS27 to PC (9-pin RS232 serial) and external battery, 1.8m.
734 161
734 162
TCPS27 B, radio modem (base), with antenna, user manual. Used as radio modem for TPS1200
(frequency range 2400 - 2483 Mhz).
TCPS27 R, radio modem (remote), with antenna, user manual. Used as external radio for PC (frequency range 2400 - 2483 MHz).
Select Power
439 038
749 279
GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.
GEV208, Power supply unit for TPS, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to TPS.
Select power cords for 12V power supply unit 749 279. Refer to “
Select Software
GeoMoS Monitor / Analyzer
”
Important:
Use the TCPS27 ConfigTool from the CD to set the correct baud rate and link number.
Enable the RTS mode in the GeoMoS Monitor software.
18
3.5 Setup of a MC75
667 237
750 242
733 297
439 038
SIM card
749 279
750 242
667 237
733 297
GFU24, Housing with Siemens MC75 GSM/GPRS Module (Quad-Band GSM 850/900/1800/1900 MHz).
Antenna for 900/1800 MHz mobile network.
GEV171, 1.8m cable to program, the Satelline 3AS radio modem inside the GFU14 housing. Also used to connect GFU24 to PC.
Select Power
439 038
749 279
GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.
GEV208, Power supply unit for TPS, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to TPS.
Select power cords for 12V power supply unit 749 279. Refer to “
Select Software
GeoMoS Monitor / Analyzer
”
19
3.6 Setup of real-time GNSS with GMX902 Sensors
747 958
766 714
722 409
632 372 (10m)
632 390 (30m)
758 600
667 140
765 734
755 267
765 733
563 809 733 280
Modem
632 372
632 390
Select Power
Select Receiver
758 600 GMX902 GG, GNSS Dual Frequency Receiver for Monitoring Applications.
Select Antenna
747 958
766 714
755 267
765 733
AX1203+ GNSS, GPS/GLONASS/Galileo Triple Frequency Antenna for all GRX1200 Series and GRX1200+
Series receivers.
AX1202 GG, Dual Frequency Antenna for GX1230 GG and GRX 1200 GG Pro Receiver
AT504 GG, GPS/GLONASS dual-frequency choke-ring antenna for GPS/GLONASS receivers. Dorne-
Margolin antenna element, JPL design. Conforms to IGS "Typ T" specification for GPS antennas. For
GX1220 / 1230, GRX1200 and GMX902 Receivers.
AR25, GNSS choke ring antenna for GPS/GLONASS/Galileo/Compass receivers. Includes L-Band signals.
Dorne-Margolin antenna element.
GVP601, Weather-protection radome for AT504 choke ring antenna. 667 140
765 734 GVP653, Weather-protection radome AR25 choke ring antenna.
Select Antenna Cables
Antenna cable, 10 m
Antenna cable, 30 m
722 409 Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.
Select power cords for 12V power supply unit 722 409. Refer to “
20
Select Communication between Sensors and Spider
733 280
563 809
GEV160, 2.8m Data transfer cable. Connects GPS1200 receiver Ports 1, 2 and 3, RX1220 or GMX902 to
PC for data transfer, firmware upload etc. Lemo 8 Pin to 9 pin RS232 female serial connector.
GEV113, 2.8m Modem cable. Connects GPS receiver Ports 1, 2 and 3 to modem. Lemo 8 Pin to 9 Pin
RS232 male serial connector.
Select Software
Leica GNSS Spider
Optional Software
GeoMoS Monitor / Analyzer
Leica GNSS QC
”
”
Note: If you connect more than one GNSS receiver to GeoMoS to use for monitoring we recommend GNSS connection to the Leica Spider software. GeoMoS supports an interface to Leica GNSS Spider software (order GNSS Spider and accessories separately)
21
3.7 Setup of post processing GNSS with GRX1200Pro Sensors
747 958
766 714
667 140
765 734
755 267
765 733
632 372 (10m )
)
766 730
766 733
722 409
733 257
745 995
733 290 563 809
LAN / WAN
733 280
Modem
Select Receiver
766 730
766 733
GRX1200+, Triple Frequency GPS Reference Station Receiver, Professional, with Event Input, PPS
Output, External Oscillator Input and Ethernet connectivity. Includes L2C.
GRX1200+, GPS/GLONASS/Galileo Triple Frequency Reference Station Receiver, Professional, with Event
Input, PPS Output, External Oscillator Input and Ethernet connectivity. Includes L2C. Requires separate
Purchasable Options software options for full time GPS L5/GLONASS and Galileo.
For additional information see
745 972 Equipment list “For GNSS Networks and Reference Stations”
Select CompactFlash Card
733 257 MCF256, CompactFlash card 256MB.
MCF1000, CompactFlash card 1GB. 745 995
Select Antenna
747 958
766 714
755 267
AX1203+ GNSS, GPS/GLONASS/Galileo Triple Frequency Antenna for all GRX1200 Series and GRX1200+
Series receivers.
AX1202 GG, Dual Frequency Antenna for GX1230 GG and GRX 1200 GG Pro Receiver
AT504 GG, GPS/GLONASS dual-frequency choke-ring antenna for GPS/GLONASS receivers. Dorne-
Margolin antenna element, JPL design. Conforms to IGS "Typ T" specification for GPS antennas. For
GX1220 / 1230, GRX1200 and GMX902 Receivers.
22
765 733
667 140
765 734
Select Antenna Cables
AR25, GNSS choke ring antenna for GPS/GLONASS/Galileo/Compass receivers. Includes L-Band signals.
Dorne-Margolin antenna element.
GVP601, Weather-protection radome for AT504 choke ring antenna.
GVP653, Weather-protection radome AR25 choke ring antenna.
632 372
632 390
Select Power
Antenna cable, 10 m
Antenna cable, 30 m
722 409 Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.
Select power cords for 12V power supply unit 722 409. Refer to “
Select Communication between Sensors and Spider
733 280
563 809
GEV160, 2.8m Data transfer cable. Connects GPS1200 receiver Ports 1, 2 and 3, RX1220 or GMX902 to
PC for data transfer, firmware upload etc. Lemo 8 Pin to 9 pin RS232 female serial connector.
GEV113, 2.8m Modem cable. Connects GPS receiver Ports 1, 2 and 3 to modem. Lemo 8 Pin to 9 Pin
RS232 male serial connector.
GEV168, 5.0m cable, connecting GPS Receiver with Ethernet LAN / RJ45 733 290
Select Software
Leica GNSS Spider
Optional Software
GeoMoS Monitor / Analyzer
Leica GNSS QC
”
”
Note: If you connect more than one GNSS receiver to GeoMoS to use for monitoring we recommend GNSS connection to the Leica Spider software. GeoMoS supports an interface to Leica GNSS Spider software (order GNSS Spider and accessories separately)
23
3.8 Setup of a Meteo Sensor
734 698
667 726
749 279
439 038
Select Sensor
667 726 DTM meteo sensor, combined pressure and temperature sensor 2m cable with Lemo1 plug. (other lengths of cable on request).
Select Sensor
734 698
764 328
GEV187, Y-cable, connects TPS to PC (9-pin RS232 serial) and external battery, 2.0m.
GEV222, Adapter cable DTM sensor, Lemo-1 (female) to Lemo-0 (female), 3.0m
Select Power
439 038
749 279
GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.
GEV208, Power supply unit for TPS, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to TPS.
Select power cords for 12V power supply unit 749 279. Refer to “
Select Software
GeoMoS Monitor / Analyzer
”
Important:
Remove the yellow transportation cover for monitoring
The DTM meteo sensor should be mounted upside down
24
3.9 Setup of a Level
734 698
723 289
726 540
744 793
749 279
439 038
738 933
741 868
Select Level
723 289
726 540
738 933
734 698
Select Power
DNA03, 0.3mm, precision digital level, magnetically-damped compensator, with user manual and container.
DNA10, 0.9mm, digital level, magnetically-damped compensator, with user manual and container.
SPRINTER 100M, 2.0mm, electronic level, with RS232 interface & internal memory, with user manual, 4 pcs AA dry cells and container.
SPRINTER 200M, 1.5mm, electronic level, with RS232 interface & internal memory, with user manual, 4 741 868 pcs AA dry cells and container.
Select Cables and Switchbox
744 793 Switchbox with cable 2.0m for TPS/1000/1100/1200 and GeoMoS. Supports cold boot for TPS
(important 24/7 hours/day monitoring)
GEV187, Y-cable, connects TPS to PC (9-pin RS232 serial) and external battery, 2.0m.
439 038
749 279
GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.
GEV208, Power supply unit for TPS, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to TPS.
Select power cords for 12V power supply unit 749 279. Refer to “
Select Staff
Refer to “ 4.3.2 DNA Staffs ” and “ 4.3.3 Sprinter Staffs ”.
Select Software
GeoMoS Monitor / Analyzer
”
25
3.10 Remote Setup of a GMX902 Sensor with Radio (GFU-14)
747 958
766 714
667 140
765 734
755 267
765 733
639 964
667 243
733 275, 733 276,
738 272, 738 273,
738 274, 738 275,
738 276
632 372 (10m)
632 390 (30m)
639 964
667 243
733 275, 733 276,
738 272, 738 273,
738 274, 738 275,
738 276
722 409
758 600
733 297
563 809
439 038
733 297
439 038
749 279
749 279
Select Receiver
758 600
Select Antenna
747 958
GMX902 GG, GNSS Dual Frequency Receiver for Monitoring Applications.
766 714
755 267
765 733
667 140
765 734
AX1203+ GNSS, GPS/GLONASS/Galileo Triple Frequency Antenna for all GRX1200 Series and GRX1200+
Series receivers.
AX1202 GG, Dual Frequency Antenna for GX1230 GG and GRX 1200 GG Pro Receiver
AT504 GG, GPS/GLONASS dual-frequency choke-ring antenna for GPS/GLONASS receivers. Dorne-
Margolin antenna element, JPL design. Conforms to IGS "Typ T" specification for GPS antennas. For
GX1220 / 1230, GRX1200 and GMX902 Receivers.
AR25, GNSS choke ring antenna for GPS/GLONASS/Galileo/Compass receivers. Includes L-Band signals.
Dorne-Margolin antenna element.
GVP601, Weather-protection radome for AT504 choke ring antenna.
GVP653, Weather-protection radome AR25 choke ring antenna.
Select Antenna Cables
632 372
632 390
Antenna cable, 10 m
Antenna cable, 30 m
Select Radio Modem
733 275 GFU14-0, Satelline 3AS radio modem (433.525 MHz, 25.0 kHz channel spacing, 0.5 W)
733 276
738 272
738 273
738 274
738 275
738 276
GFU14-1, Satelline 3AS radio modem (406.425 MHz, 25.0 kHz channel spacing, 1.0 W)
GFU14-2, Satelline 3AS radio modem (445.000 MHz, 12.5 kHz channel spacing, 1.0 W)
GFU14-3, Satelline 3AS radio modem (443.000 MHz, 12.5 kHz channel spacing, 1.0 W)
GFU14-4, Satelline 3AS radio modem (440.550 MHz, 25.0 kHz channel spacing, 0.5 W)
GFU14-5, Satelline 3AS radio modem (458.150 MHz, 12.5 kHz channel spacing, 0.5 W)
GFU14-6, Satelline 3AS radio modem (439.8625 MHz, 12.5 kHz channel spacing, 1.0 W)
26
Select Radio Antenna
639 964 GAT1, Gainflex radio antenna, frequency range 400-435MHz.
GAT2, Gainflex radio antenna, frequency range 435-470MHz. 667 243
Select Power
439 038
749 279
GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.
GEV208, Power supply unit for TPS, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to TPS.
Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, 722 409 cable with 5-pin Lemo to connect to GPS.
Select power cords for 12V power supply unit 722 409 and 749 279. Refer to “ 5 Power supply
”.
Select Communication Cables
563 809 GEV113, 2.8m Modem cable. Connects GPS receiver Ports 1, 2 and 3 to modem. Lemo 8 Pin to 9 Pin
733 297
Select Software
Leica GNSS Spider
Optional Software
RS232 male serial connector.
GEV171, 1.8m cable to program, the Satelline 3AS radio modem inside the GFU14 housing
GeoMoS Monitor / Analyzer
Leica GNSS QC
”
”
Note: If you connect more than one GNSS receiver to GeoMoS to use for monitoring we recommend GNSS connection to the Leica Spider software. GeoMoS supports an interface to Leica GNSS Spider software (order GNSS Spider and accessories separately)
27
3.11 Setup of a GNSS Sensor co-located with a Total Station
747 958
766 714
667 140
765 734
755 267
765 733
632 372 (10m)
632 390 (30m)
722 409
758 600
664 662
757 129
764 824
733 280
734 698
759 257
744 793
772 630
439 038
749 279
Select Total Station
664 662
757 129
764 824
TCA2003, 0.5"(0.15mgon) automatic precision total station, with laser plummet, 2 control panels, accessories, user manual and container.
TM30 0.5”, 0.15gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.
TM30 1”, 0.3gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.
Select Cables and Switchbox
744 793
772 630
734 698
Switchbox with cable 2.0m for TPS/1000/1100/1200 and GeoMoS. Supports cold boot for TPS
(important 24/7 hours/day monitoring)
GDZ 68, Switchbox with a 2.0m cable for TM30/TS30 (Lemo 1) and GeoMoS. Supports cold boot for
TPS (important 24/7 hours/day monitoring).
GEV187, Y-cable, connects TPS/1000/1100/1200 to PC (9-pin RS232 serial) and external battery, 2.0m.
GEV220, Y-cable, connects TM30/TS30 to PC (9-pin RS232 serial) and external battery, 2.0m. 759 257
Select Receiver
758 600
733 280
GMX902 GG, GNSS Dual Frequency Receiver for Monitoring Applications.
Communication Cable
GEV160, 2.8m Data transfer cable. Connects GPS1200 receiver Ports 1, 2 and 3, RX1220 or GMX902 to
PC for data transfer, firmware upload etc. Lemo 8 Pin to 9 pin RS232 female serial connector.
28
Select Antenna
747 958
766 714
755 267
765 733
667 140
765 734
AX1203+ GNSS, GPS/GLONASS/Galileo Triple Frequency Antenna for all GRX1200 Series and GRX1200+
Series receivers.
AX1202 GG, Dual Frequency Antenna for GX1230 GG and GRX 1200 GG Pro Receiver
AT504 GG, GPS/GLONASS dual-frequency choke-ring antenna for GPS/GLONASS receivers. Dorne-
Margolin antenna element, JPL design. Conforms to IGS "Typ T" specification for GPS antennas. For
GX1220 / 1230, GRX1200 and GMX902 Receivers.
AR25, GNSS choke ring antenna for GPS/GLONASS/Galileo/Compass receivers. Includes L-Band signals.
Dorne-Margolin antenna element.
GVP601, Weather-protection radome for AT504 choke ring antenna.
GVP653, Weather-protection radome AR25 choke ring antenna.
Select Antenna Cables
632 372 Antenna cable, 10 m
632 390 Antenna cable, 30 m
Select Power
439 038
749 279
GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.
GEV208, Power supply unit for TPS, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD,
722 409 cable with 5-pin Lemo to connect to TPS.
Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.
Select power cords for 12V power supply unit 722 409 and 749 279. Refer to “ 5 Power supply
”.
Select Software
GeoMoS Monitor / Analyzer
Leica GNSS Spider
Leica GNSS QC
”
Refer to “ 4.2.4 GNSS Spider ”
”
Note: If you connect more than one GNSS receiver to GeoMoS to use for monitoring we recommend GNSS connection to the Leica Spider software. GeoMoS supports an interface to Leica GNSS Spider software (order GNSS Spider and accessories separately)
29
3.12 Setup of a GMX901 Sensor with standard cables
439 038 560 130
636 972
743 389
722 409
755 231
Select Receiver
755 231
Select Power
GMX901, GPS Smart Antenna for Monitoring Applications
439 038
722 409
GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.
Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.
Select power cords for 12V power supply unit 722 409. Refer to “
To connect battery, car battery or alternate power supply
560 130 1.8m cable, connects GEB171 external battery to GPS1200 receiver. Lemo-1, 5 pin, male to Lemo-1, 5
636 972 pin, male.
0.5m cable, connects GEB171 external battery to GPS1200 receiver. Lemo-1, 5 pin, male to Lemo-1, 5 pin, male.
Select Communication between Sensors and Spider
743 389
Select Software
GEV197, Y-Cable, 2.8m, GMX901 to RS232 and external Leica power supply.
Leica GNSS Spider
Optional Software
GeoMoS Monitor / Analyzer
Leica GNSS QC
”
”
Note: If you connect more than one GNSS receiver to GeoMoS to use for monitoring we recommend GNSS connection to the Leica Spider software. GeoMoS supports an interface to Leica GNSS Spider software (order GNSS Spider and accessories separately)
30
3.13 Setup of a GMX901 Sensor with custom wired cables
755 231
750 073
3
4 blue green
5 black
7 red
GND
Data In
Data In
Data Out
GND
Data Out
PWR In
GND
PWR In
Select Receiver
755 231 GMX901, GPS Smart Antenna for Monitoring Applications
Power / Communication
750 073
Select Software
GEV212, Interface Cable, 5m, GMX901 to unterminated, connects GMX901 to a custom installation.
Leica GNSS Spider
Optional Software
GeoMoS Monitor / Analyzer
Leica GNSS QC
”
”
Note: If you connect more than one GNSS receiver to GeoMoS to use for monitoring we recommend GNSS connection to the Leica Spider software. GeoMoS supports an interface to Leica GNSS Spider software (order GNSS Spider and accessories separately)
31
3.14 Remote Setup of a GMX901 Sensor with Radio (GFU-14)
439 038 560 130
636 972 755 231
743 389
Solar panel / Battery
Mini Adapter
439 038
733 297
639 964
667 243
733 275, 733 276,
738 272, 738 273,
738 274, 738 275,
738 276
439 038
749 279
733 297
639 964
667 243
733 275, 733 276,
738 272, 738 273,
738 274, 738 275,
738 276
Select Receiver
755 231
Select Accessories
GMX901, GPS Smart Antenna for Monitoring Applications
Mini adapter
Null modem, DB9 male to DB9 male. Refer to “
”.
Select Radio Modem
733 275 GFU14-0, Satelline 3AS radio modem (433.525 MHz, 25.0 kHz channel spacing, 0.5 W)
733 276
738 272
738 273
738 274
GFU14-1, Satelline 3AS radio modem (406.425 MHz, 25.0 kHz channel spacing, 1.0 W)
GFU14-2, Satelline 3AS radio modem (445.000 MHz, 12.5 kHz channel spacing, 1.0 W)
GFU14-3, Satelline 3AS radio modem (443.000 MHz, 12.5 kHz channel spacing, 1.0 W)
GFU14-4, Satelline 3AS radio modem (440.550 MHz, 25.0 kHz channel spacing, 0.5 W)
32
738 275
738 276
GFU14-5, Satelline 3AS radio modem (458.150 MHz, 12.5 kHz channel spacing, 0.5 W)
GFU14-6, Satelline 3AS radio modem (439.8625 MHz, 12.5 kHz channel spacing, 1.0 W)
Select Radio Antenna
639 964 GAT1, Gainflex radio antenna, frequency range 400-435MHz.
GAT2, Gainflex radio antenna, frequency range 435-470MHz. 667 243
Select Power
439 038
749 279
GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.
GEV208, Power supply unit for TPS, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to TPS.
Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, 722 409 cable with 5-pin Lemo to connect to GPS.
Select power cords for 12V power supply unit 722 409 and 749 279. Refer to “ 5 Power supply
”.
To connect battery, car battery or alternate power supply
560 130 1.8m cable, connects GEB171 external battery to GPS1200 receiver. Lemo-1, 5 pin, male to Lemo-1, 5
636 972 pin, male.
0.5m cable, connects GEB171 external battery to GPS1200 receiver. Lemo-1, 5 pin, male to Lemo-1, 5 pin, male.
Select Communication Cables
733 297
743 389
Select Software
GEV171, 1.8m cable to program, the Satelline 3AS radio modem inside the GFU14 housing
GEV197, Y-Cable, 2.8m, GMX901 to RS232 and external Leica power supply.
Leica GNSS Spider
Optional Software
GeoMoS Monitor / Analyzer
Leica GNSS QC
”
”
Note: If you connect more than one GNSS receiver to GeoMoS to use for monitoring we recommend GNSS connection to the Leica Spider software. GeoMoS supports an interface to Leica GNSS Spider software (order GNSS Spider and accessories separately)
33
3.15 Setup of a Nivel210 (RS232)
576 198
802 902
PC
748 335
722 409
Select Sensor
576 198 NIVEL210, inclination sensor with RS232 interface
Select Cables and Accessories
748 335
802 902
749 031
Select Power
GEV204, Power supply-cab.f. NIVEL210/230
Cable, PC- NIVEL210, (Lemo-RS232), 1m
GHT59, Wall Mounting Kit for NIVEL200
722 409 Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.
Select power cords for 12V power supply unit 722 409. Refer to “
Select Software
Important
GeoMoS Monitor / Analyzer
GNSS QC
”
”
Use the NivelTool software from the CD to set the correct Nivel ID and baud rate.
34
3.16 Setup of a Nivel210 with GRX1200Pro Series
747 958
766 714
667 140
765 734
755 267
765 733
722 409
766 730
766 733
749 916
733 257
745 995
576 198
733 280
Select Sensor
576 198 NIVEL210, inclination sensor with RS232 interface
Select Cables and Accessories
749 916 GEV209, Cable, NIVEL210 - GPS1200, 1.8m
733 280 GEV160, 2.8m Data transfer cable. Connects GPS1200 receiver Ports 1, 2 and 3, RX1220 or GMX902 to
PC for data transfer, firmware upload etc. Lemo 8 to 9 pin RS232 female serial connector.
GHT59, Wall Mounting Kit for NIVEL200 749 031
Select Receiver
766 730
766 733
GRX1200+, Triple Frequency GPS Reference Station Receiver, Professional, with Event Input, PPS
Output, External Oscillator Input and Ethernet connectivity. Includes L2C.
GRX1200+, GPS/GLONASS/Galileo Triple Frequency Reference Station Receiver, Professional, with Event
Input, PPS Output, External Oscillator Input and Ethernet connectivity. Includes L2C. Requires separate software options for full time GPS L5/GLONASS and Galileo.
Purchasable Options
For additional information see
745 972 Equipment list “For GNSS Networks and Reference Stations”
Select CompactFlash Card
733 257
745 995
MCF256, CompactFlash card 256MB.
MCF1000, CompactFlash card 1GB.
Select Antenna
747 958
766 714
AX1203+ GNSS, GPS/GLONASS/Galileo Triple Frequency Antenna for all GRX1200 Series and GRX1200+
Series receivers.
AX1202 GG, Dual Frequency Antenna for GX1230 GG and GRX 1200 GG Pro Receiver
35
755 267
765 733
AT504 GG, GPS/GLONASS dual-frequency choke-ring antenna for GPS/GLONASS receivers. Dorne-
Margolin antenna element, JPL design. Conforms to IGS "Typ T" specification for GPS antennas. For
GX1220 / 1230, GRX1200 and GMX902 Receivers.
AR25, GNSS choke ring antenna for GPS/GLONASS/Galileo/Compass receivers. Includes L-Band signals.
Dorne-Margolin antenna element.
GVP601, Weather-protection radome for AT504 choke ring antenna. 667 140
765 734 GVP653, Weather-protection radome AR25 choke ring antenna.
Select Antenna Cables
632 372
632 390
Select Power
Antenna cable, 10 m
Antenna cable, 30 m
722 409 Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.
Select power cords for 12V power supply unit 722 409. Refer to “
Select Software
GRX onboard software
Important Use the NivelTool software from the CD to set the correct Nivel ID and baud rate.
36
3.17 Setup of a Nivel220 (RS485) with Leica cables
Cables supplied by Leica Geosystems
567 199
567 199
567 199
575 869
RS232 cable
Converter
802 906 or
802 907
722 409
748 488 802 906 or
802 907
Select Sensor
576 199 NIVEL220, inclination sensor with R4852 interface
Select Cables and Accessories
748 488
748 489
0.8m power supply cable, connects power supply unit 722 409 to RS232/RS485 converter, Lemo-0 to
2 wires to terminal strip.
1.8m communication cable, connects Nivel220 to RS232/RS485 converter, Lemo-0 to 4 wires to terminal strip.
5.0m connection cable RS485. Connects two Nivel220 sensor ports 1 or 2, Lemo-0 to Lemo-0. 802 906
802 907
575 869
RS232 cable
20.0m connection cable RS485. Connects two Nivel220 sensor ports 1 or 2, Lemo-0 to Lemo-0.
Terminator 120 Ohm, for RS485 Bus
DB9 cable, DB9 male to DB9 female. Refer to “ 9.7.1 Cables ”.
Converter RS232/RS485 converter. Refer to “
749 031
Select Power
GHT59, Wall Mounting Kit for NIVEL200
722 409 Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.
Select power cords for 12V power supply unit 722 409. Refer to “
Select Software
GeoMoS Monitor / Analyzer
GNSS QC
”
”
Important Use the NivelTool software from the CD to set the correct Nivel ID and baud rate.
37
3.18 Setup of a Nivel220 (RS485) with long cables
Cables supplied by Leica Geosystems and CAT cables
General information
For the installation of the cables of the Nivel220 sensors, the general rules for the installation of electrical wiring apply.
Avoid sharp bends and lay the cable in large loops within the range of rotating or moving parts.
When installing the cables, please observe the already existing installation of electric system.
After having completed the installation, please drive through all possible positions in order to make sure that the cables are not touching, stretched or even squeezed by any moving parts.
Please consider that a well-planned and thoroughly carried out electric installation does not only protect the cables against damages, but also looks professional.
Sensor auxiliary supply
Power for the Nivel220 sensor must be supplied externally. The power is connected to the sensor using a LEMO cable.
The auxiliary supply voltage at the Nivel220 sensor must be within the permissible range. Refer to "Nivel 200 User Manual". The correct operation of the sensor cannot be guaranteed when the supply voltage is not within this range and it can be damaged by overvoltages. For the voltage drop along long supply cables take into account and, if necessary, correspondingly increase the voltage at the supply end. The voltage drop is given by the following equation: voltage drop [V] = resistance per m [Ω/m] * 2 * cable length [m] * current [A]
It can be assumed that the voltage drop is varying should the current through the sensor appear to fluctuate. A Nivel220 requires typically 50mA. Refer to "Nivel 200 User Manual".
Use the Leica Geosystems power supply recommended by Leica Geosystems to ensure the correct functionality of the Nivel220 sensor.
Voltage drop computation
225 m 45 m 45 m
Power supply
150 mA 100 mA 50 mA
220V
N1 N2 N3
12.00 V voltage drop [V] = 0.1 [Ω/m] * 2 * 225 [m] * 0.15 [A] = 6.75 [V] voltage drop [V] = 0.1 [Ω/m] * 2 * 45 [m] * 0.10 [A] = 0.90 [V] voltage drop [V] = 0.1 [Ω/m] * 2 * 45 [m] * 0.05 [A] = 0.45 [V]
total amount voltage drop = 8.10 [V]
5.25 V 4.35 V 3.90 V
38
With one power source
RS232 cable
722 409
748 488
Converter
567 199
748 489
567 199
575 869
748 489
748 489
Terminal strip
Terminal strip
Terminal strip
CAT6 cable
748 489
CAT6 cable
Select Sensor
576 199 NIVEL220, inclination sensor with R4852 interface
Select Cables and Accessories
748 488 0.8m power supply cable, connects power supply unit 722 409 to RS232/RS485 converter,
Lemo-0 to 2 wires to terminal strip.
1.8m communication cable, connects Nivel220 to RS232/RS485 converter, Lemo-0 to 4 wires
575 869
RS232 cable
Converter
Terminal strip
CAT6 cable
749 031
Select Power to terminal strip.
Terminator 120 Ohm, for RS485 Bus
DB9 cable, DB9 male to DB9 female. Refer to “
”.
RS232/RS485 converter. Refer to “ 9.1 RS232/RS485 converter
”.
GHT59, Wall Mounting Kit for NIVEL200
722 409 Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.
Select power cords for 12V power supply unit 722 409. Refer to “
Select Software
Important
GeoMoS Monitor / Analyzer
GNSS QC
”
”
Use the NivelTool software from the CD to set the correct Nivel ID and baud rate.
39
With multiple power sources
RS232 cable
722 409
748 488
Converter
567 199
748 489
567 199
Terminal strip
CAT6 cable
748 488
748 489
748 489
Terminal strip
Terminal strip
CAT6 cable
748 488
722 409
722 409
Equipment list see above “With one power source”
575 869
40
Sensors
4.1 TPS Sensors
4.1.1 Supported Sensors
Leica TPS 1000 Series
Leica TPS 1100 Series
Leica TPS 1200 Series
Note: Only automated TPS can be used with GeoMoS. Instruments with ATR are recommended.
TM30, TCA2003 and TCA1800 instruments are recommended.
664 662
667 016
TCA2003, 0.5"(0.15mgon) automatic precision total station, with laser plummet, 2 control panels, accessories, user manual and container.
TCA1800, 1"(0.3mgon) automatic total station with laser plummet, 2 control panels, accessories, user manual and container. recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container. recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container. recognition, Power Search, communication sidecover, internal memory, laser plummet, 2 keyboard, electronic guide light EGL, standard applications, user manuals, and upright container.
TCA1201M instruments are recommended for long-range monitoring (>1000m)
748 872 TCA1201M, total station with long-range EDM for monitoring, automatic target recognition, laser plummet, 1 keyboard with touch screen, electronic guide light EGL, standard applications, user manual, and container.
Customer Care Packages
A wide selection of comprehensive Customer Care Packages is available bundling Hardware
Maintenance, Software Maintenance, Customer Support and Extended Warranty. For more information about the CCP offering in your country please contact your local Leica Geosystems organization or distribution partner.
41
4.1.2 Supported Reflectors
The number of prisms needed is dependent on the project.
Circular reflector
641 617 Circular prism GPR121 PRO, with holder and target plate
Monitoring prisms
726 295
726 296
727 406
GPR112 Monitoring-Mining Prism, with M8 internal thread in the back for direct mounting and 5/8" adapter.
GHT112 Mounting set for GPR112 with M8 and 5/8" internal thread adapters, suitable for direct fixing systems on nearly every surface, prism is adjustable and fixable in two axes.
GDZ112, rain shelter for Monitoring Mining Prism GPR112. Full availability of the prism even in rainy conditions. The rain shelter protects the prism front against rain drops and dust which is washed out from of the air by rain.
Precision reflector
555 631
Mini prism for short distances
641 662
Single-prism precision reflector GPH1P.
641 762
Mini prism GMP101, incl. bubble, target plate and spike, in bag, also suitable for GLS11 and GRT44 (same height as GPH1, additive constant +17.5mm)
Mini prism GMP104, with L-bar, for fixed installations.
360° Reflectors
639 985
754 384
GRZ4 360° Reflector.
Reflector with 5/8" thread adapter for mounting of GPS antenna.
4.1.3 Tribrachs
443 603
667 304
4.1.4 Other TPS Accessories
Tribrach GDF21 for TPS1000 Series, without optical plummet, light green.
Tribrach GDF121 PRO for TPS1200 Series, without optical plummet, pale green.
For additional information see:
740 623
738 605
761 756
Leica System 2000 Brochure.
Leica TPS1200 Series Equipment List
Leica Original Accessories Program
42
4.2 GNSS Sensors
4.2.1 Supported Sensors
Leica GPS System 500
Leica GPS System 1200
Leica GMX900 Series
For detailed description and article numbers see Equipment lists for System 500/1200 and Equipment list for GNSS Networks and Reference Stations.
Note: The particular of model of that GNSS that is recommended depends on how the sensor connection is made to GeoMoS. If the GNSS is to be directly connected to GeoMoS (computation done on the sensor), RTK rover GNSS must be used. If the position computation is to be done by Leica GNSS Spider (recommended) then reference station GNSS or monitoring receivers should be used.
GNSS Sensors for Direct Connection to GeoMoS (RTK)
766 710
766 711
GX1220+, Geodetic GPS Dual Frequency Receiver. Sensor can be upgraded to GNSS receiver
GX1230+, Geodetic GPS Dual Frequency RTK Receiver. Sensor can be upgraded to GNSS receiver
GNSS Sensors for Connection via GNSS Spider
766 730
766 733
Monitoring receiver
755 231
758 600
GRX1200+, Triple Frequency GPS Reference Station Receiver, Professional, with Event
Input, PPS Output, External Oscillator Input and Ethernet connectivity. Includes L2C.
GRX1200+, GPS/GLONASS/Galileo Triple Frequency Reference Station Receiver,
Professional, with Event Input, PPS Output, External Oscillator Input and Ethernet connectivity. Includes L2C. Requires separate software options for full time GPS
L5/GLONASS and Galileo.
GMX901, GPS Smart Antenna for Monitoring Applications
GMX902 GG, GNSS Dual Frequency Receiver for Monitoring Applications.
Purchasable Options
For additional information see
745 972 Equipment list “For GNSS Networks and Reference Stations”
Customer Care Packages
A wide selection of comprehensive Customer Care Packages is available bundling Hardware
Maintenance, Software Maintenance, Customer Support and Extended Warranty. For more information about the CCP offering in your country please contact your local Leica Geosystems organization or distribution partner.
Extended Warranty
89 332
5301720
5301721
5301722
5301723
5301724
1 year extended warranty for GMX902 GG
2 year extended warranty for GMX902 GG
Add 1 year GMX902 GG Warranty Extension
1 year extended warranty for GMX901
2 year extended warranty for GMX901
Add 1 year GMX901 Warranty Extension
43
Purchasable Options
744 590
758 420
GSW475, Sensor upgrade from GRX1200 Lite to GRX1200 Classic
GSW619, Sensor upgrade from GRX1200 Pro to GRX1200 GG Pro, incl. permanent
GLONASS functionality. Only for GRX1200 Pro sensors with serial numbers between
355001 and 360000. For sensors outside this range, only GSW567 is required.
GMX900 Series vs GRX1200 Series - Differentiation
12 channels GPS, 1Hz L1 code/phase receiver
120 channels GPS, 20Hz L1/L2 code/phase receiver
+L5
120 channels GPS, GLONASS, Galileo, 20Hz L1/L2 code/phase receiver
- yes - yes -
Raw data logging onboard the receiver
RTK corrections directly from the receiver
Configuration and status display with web interface yes yes yes yes yes
- - - yes yes
-
-
-
-
-
- yes yes yes yes
RT and PP coordinate calculation using GNSS Spider
Advanced reference station firmware functionality
Number of serial ports
Advanced I/O ports yes
-
1
- yes
-
2
PPS yes
-
2
PPS yes yes
4
PPS. Event,
External
Oscillator,
Ethernet yes yes
4
PPS. Event,
External
Oscillator,
Ethernet
1.7 W 2.4 W 2.0 W 3.6 W 3.6 W yes yes yes yes yes yes yes yes yes yes
Power consumption
IP67
Operating temperature –40° to +65°C
4.2.2 Antennas
747 958
766 714
755 267
765 733
AX1203+ GNSS, GPS/GLONASS/Galileo Triple Frequency Antenna for all GRX1200 Series and GRX1200+ Series receivers.
AX1202 GG, Dual Frequency Antenna for GX1230 GG and GRX 1200 GG Pro Receiver
AT504 GG, GPS/GLONASS dual-frequency choke-ring antenna for GPS/GLONASS receivers. Dorne-Margolin antenna element, JPL design. Conforms to IGS "Typ T" specification for GPS antennas. For GX1220 / 1230, GRX1200 and GMX902 Receivers.
AR25, GNSS choke ring antenna for GPS/GLONASS/Galileo/Compass receivers. Includes L-
Band signals. Dorne-Margolin antenna element.
GVP601, Weather-protection radome for AT504 choke ring antenna.
GVP653, Weather-protection radome AR25 choke ring antenna.
667 140
765 734
4.2.3 GNSS Accessories
667 200
636 959
632 372
632 390
664 813
713 483
733 257
Antenna cable, 1.2 m
Antenna cable, 2.8 m
Antenna cable, 10.0 m
Antenna cable, 30.0 m
Antenna cable, 50.0 m
Antenna cable, 70.0 m
MCF256, CompactFlash card 256MB.
44
745 995
4.2.4 GNSS Spider
MCF1000, CompactFlash card 1GB.
All active RT Positioning Products and PP Positioning Products configured in GNSS Spider with the Send To option set to GeoMoS can be used in GeoMoS. Thus many GNSS sensors maybe connected using a single entry in the GeoMoS Sensor Manager.
Required Options for Real Time Monitoring (RT Positioning Products)
740 244
744 912
Leica GNSS Spider, GNSS Reference Station Software, general license, with documentation. Supports full receiver control and configuration, manual downloads and firmware upgrade. Not protected.
Spider, Positioning Site license.
Required for each GNSS site/sensor that shall be used for the Spider position processing. A minimum of two (2) of these licenses is needed for Positioning.
Required Options for Post Processed Monitoring (PP Positioning Products)
740 244
744 912
744 904
734 613
Leica GNSS Spider, GNSS Reference Station Software, general license, with documentation. Supports full receiver control and configuration, manual downloads and firmware upgrade. Not protected.
Spider, Positioning Site license.
Required for each GNSS site/sensor that shall be used for the Spider position processing. A minimum of two (2) of these licenses is needed for Positioning.
Spider, File Products Service (FPS) option. Provides automated data download and management for multiple sites with automated RINEX conversion, quality control, event logging, FTP transfer for distributing Spider product files on the Internet. Option includes one (1) site/sensor license. For more site/sensor licenses for a Spider FPS, order one or more "Spider, FPS Additional Site License" as required.
Spider, FPS Additional Site License. Required for each GNSS site/sensor that shall be used with Spider File Product Service in addition to the default one (1) site/sensor, which is included as standard.
Note: 744912 Positioning Site Licences are cumulative between Real-Time and Post-Processing Positioning Products.
For example, to use 10 sites simultaneously in both Real-Time and Post-Processing Products requires 20 Positioning
Site Licences. There is no limit to the number of Positioning Products (baselines) that may be configured if the number of sites used (including reference and rover sites) does not exceed the number of Positioning Site Licences.
For additional information see:
745 972 Equipment list “For GNSS Networks and Reference Stations”
4.2.5 GNSS QC
GNSS QC can be used as an alternative to GeoMoS as a low cost analyzer for use together with GNSS Spider for GPS-only monitoring. The Advanced Coordinate Analysis option includes support for 20Hz real time NMEA data, Spider post processing data, profiling, limit checks and messaging. GNSS QC can be also used for site selection and quality checking of the raw GNSS data.
Required Options for Analysis of Real Time and Post Processed Positioning Data from Spider
749 319
751 824
Leica GNSS QC, GNSS Reference Station software with documentation. For data analysis and quality control of GNSS reference station data. Dongle protected.
GNSS QC, Advanced Coordinate Analysis option. High speed calculation and graphing of displacement, messaging and limit checks for real time NMEA and GNSS Spider Post
Processing coordinate data. Dongle protected.
For additional information see:
745 972 Equipment list “For GNSS Networks and Reference Stations”
45
4.3 Levels
4.3.1 Supported Sensors
723 289
726 540
738 933
741 868
Customer Care Packages
DNA03, 0.3mm, precision digital level, magnetically-damped compensator, with user manual and container.
DNA10, 0.9mm, digital level, magnetically-damped compensator, with user manual and container.
SPRINTER 100M, 2.0mm, electronic level, with RS232 interface & internal memory, with user manual, 4 pcs AA dry cells and container.
SPRINTER 200M, 1.5mm, electronic level, with RS232 interface & internal memory, with user manual, 4 pcs AA dry cells and container.
A wide selection of comprehensive Customer Care Packages is available bundling Hardware
Maintenance, Software Maintenance, Customer Support and Extended Warranty. For more information about the CCP offering in your country please contact your local Leica Geosystems organization or distribution partner.
4.3.2 DNA Staffs
560 271
560 274
563 659
632 313
563 733
522 793
667 113
Invar bar code levelling staff GPCL3, 3m, with circular level.
Invar bar code levelling staff GPCL3, 3m, with circular level, with expansion coefficient certificate and length calibration certificate.
Invar bar code levelling staff GPCL2, 2m, with circular level.
Industrial bar code levelling staff GWCL92, 92 cm, invar staff with circular bubble and 2 interchangeable bases.
Invar bar code scale GWCL60, 60 cm
Dual face levelling staff GKNL4F, 13.3ft, 3 sections, code/ft graduation, with handles and circular bubble, in transport bag
Telescopic levelling staff GTL4C, 4m, aluminium, bar code/mm-graduation, with bull`seye bubble, in transport bag
4.3.3 Sprinter Staffs
741 882
741 883
741 884
741 885
741 886
746 613
746 614
GSS111, Dual face telescopic levelling staff, 5m, 4 sections, SPRINTER barcode / E-Scale cm-graduation, with circular bubble, in transport bag (Standard version).
GSS111-1, Dual face telescopic levelling staff, 5m (16.4ft), 4 sections, SPRINTER barcode / ft-graduation, with circular bubble, in transport bag, (Imperial version).
GSS112-3, Dual face telescopic levelling staff, 4m, 4 sections, SPRINTER barcode / E-
Scale cm-graduation, with circular bubble, in transport bag (UK version).
GSS111-2, Dual face telescopic levelling staff, 5m, 4 sections, SPRINTER barcode / 5mmgraduation, with circular bubble, in transport bag (Japan version).
GSS112-5, Dual face telescopic levelling staff, 4m, 4 sections, SPRINTER barcode / 2mmgraduation, with circular bubble, in transport bag (Spain version).
GSS112, Dual face telescopic levelling staff, 4m, 4 sections, SPRINTER barcode / E-Scale cm-graduation, with circular bubble, in transport bag (Standard version).
GSS122-3, Dual face telescopic (Fibreglass) levelling staff, 4m, 4 sections, SPRINTER barcode / E-Scale cm-graduation, with circular bubble, in carry case (UK version).
For additional information see:
761 756 Leica Original Accessories Program
46
4.4 Other Sensors
4.4.1 Inclination Sensors
The Nivel20 and Nivel200 are a series of highly precise inclination sensors from Leica Geosystems. The following instruments are supported.
576 198
576 199
NIVEL210, inclination sensor with RS232 interface
NIVEL220, inclination sensor with RS485 interface
575 869 Terminator for RS485. One terminator must be ordered and installed for each installation with Nivel220 sensors.
Other accessories
Inclination Sensors need to have mounting, shelters and cables.
749 031 GHT59, Wall Mounting Kit for NIVEL200
For cables refer to “ 6.6 Nivel210 / Nivel220 cables
”.
For additional information see:
749 597 "Leica Nivel210 and Nivel220 sensors Equipment List"
4.4.2 Meteo Sensors
667 726 STS DTM meteo sensor, combined pressure and temperature sensor, 2.0m cable with
Lemo 1
Other accessories
Meteo Sensors need to have mountings, shelters and cables.
Refer to “ 6.7 Meteo sensor cables ” to connect a meteo sensor.
Refer to “ 3.8 Setup a Meteo Sensor ”.
47
Power supply
The PC and the sensors need to have a permanent power supply.
Do not us an internal battery when using the Switchbox (744 794).
5.1 Continuous 12V Power supply for GPS1200 and NIVEL sensors
A permanent 12V power supply is needed for sensors
722 409 Power supply unit, for indoor use only, input 100V-240VAC 50-60HZ, output 12VDC, cable with 5-pin Lemo.
Standard mains/line cable select from following list.
Select power cords for 12V power supply unit 722 409:
731 772
731 773
Power Cord for Dual Bay Charger GKL24 or Power supply unit, US-Version.
Power Cord for Dual Bay Charger GKL24 or Power supply unit, EU-Version.
734 232
734 233
738 586
Power Cord for Dual Bay Charger GKL24 or Power supply unit, UK-Version.
Power Cord for Dual Bay Charger GKL24 or Power supply unit, AUS-Version.
Power Cord for Dual Bay Charger GKL24 or Power supply unit, CH-Version.
5.2 Continuous 12V Power supply for TPS sensors
A permanent 12V power supply is needed for sensors
749 279 GEV208, Power supply unit for TPS, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect power cables.
Standard mains/line cable select from the following list.
Select power cords for 12V power supply unit 749 279:
731 722
731 773
Power Cord, US-Version.
Power Cord, EU-Version.
734 232
734 233
738 586
Power Cord, UK-Version.
Power Cord, AUS-Version.
Power Cord, CH-Version.
48
Cables
A permanent power supply is needed during the measurements.
The communication between sensor and PC has to be permanently connected during the measurements.
6.1 Total station cables
439 038
734 698
759 257
GEV71, 4m car battery cable, connects TPS or GPS receiver (Lemo-1, 5 pin, female) to
12V car battery. (Note, for TPS e.g. the additional cable 734 698 is required.)
GEV187, Y-cable, connects TPS to PC (9-pin RS232 serial) and external battery, 2.0m.
GEV220, Y-cable, connects TM30/TS30 to PC (9-pin RS232 serial) and external battery,
2.0m.
6.2 GPS1200 / GMX902 cables
To connect two independent power supplies
733 298 GEV172, 2.8m Y-cable, connects GPS Receiver with two external power supplies.
To connect battery, car battery or alternate power supply
439 038 GEV71, 4m car battery cable, connects TPS or GPS receiver (Lemo-1, 5 pin, female) to
12V car battery. (Note, for GPS e.g. the 560 130 or 636 972 is required.)
560 130
636 972
1.8m cable, connects GEB171 external battery to GPS1200 receiver. Lemo-1, 5 pin, male to Lemo-1, 5 pin, male.
0.5m cable, connects GEB171 external battery to GPS1200 receiver. Lemo-1, 5 pin, male
722 411 to Lemo-1, 5 pin, male.
Cable with protection fuse to connect 12V power supply to GPS receiver.
To transfer data between sensor and spider
733 280 GEV160, 2.8m Data transfer cable. Connects GPS1200 receiver Ports 1, 2 and 3, RX1220 or GMX902 to PC for data transfer, firmware upload etc. Lemo 8 to 9 pin RS232 female serial connector.
563 809 GEV113, 2.8m Modem cable. Connects GPS receiver Ports 1, 2 and 3 to modem. Lemo 8
Pin to 9 Pin RS232 male serial connector.
733 290 GEV168, 5.0m cable, connecting GPS Receiver with Ethernet LAN / RJ45
6.3 GMX901 cables
750 073
743 389
GEV212, Interface Cable, 5m, GMX901 to unterminated, connects GMX901 to a custom installation.
GEV197, Y-Cable, 2.8m, GMX901 to RS232 and external Leica power supply.
49
6.4 Antenna cables
6.5 Level cables
667 200
636 959
632 372
632 390
664 813
713 483
Antenna cable, 1.2 m
Antenna cable, 2.8 m
Antenna cable, 10.0 m
Antenna cable, 30.0 m
Antenna cable, 50.0 m
Antenna cable, 70.0 m
439 038
734 698
GEV71, 4m car battery cable, connects TPS or GPS receiver (Lemo-1, 5 pin, female) to
12V car battery. (Note, for TPS e.g. the additional cable 734 698 is required.)
GEV187, Y-cable, connects TPS to PC (9-pin RS232 serial) and external battery, 2.0m.
6.6 Nivel210 / Nivel220 cables
To connect a Nivel210 directly to GPS1200
749 916 1.8m communication and connection cable, GEV209, Nivel210 to GPS1200
To connect a Nivel210 directly to PC
802 902 1.0m connection cable, connects Nivel210 sensor ports 1 or 2 to PC for data communication etc., Lemo-0 to 9 pin RS232 serial connector.
748 335 GEV204, Power supply-cable for NIVEL210 and NIVEL230. (Lemo -Lemo), 1.8m.
To connect a Nivel220
802 906
802 907
748 488
748 489
5.0m connection cable RS485. Connects two Nivel220 sensor ports 1 or 2, Lemo-0 to
Lemo-0.
20.0m connection cable RS485. Connects two Nivel220 sensor ports 1 or 2, Lemo-0 to
Lemo-0.
0.8m power supply cable, connects power supply unit 722 409 to RS232/RS485 converter, Lemo-0 to 2 wires to terminal strip.
1.8m communication cable, connects Nivel220 to RS232/RS485 converter, Lemo-0 to 4 wires to terminal strip.
50
6.7 Meteo sensor cables
To connect GEV187 and DTM meteo sensor
764 328 GEV222, Adapter cable DTM sensor, Lemo-1 (female) to Lemo-0 (female), 3.0m
734 698 GEV187, Y-cable, connects TPS to PC (9-pin RS232 serial) and external battery, 2.0m.
439 038 GEV71, 4m car battery cable, connects TPS or GPS receiver (Lemo-1, 5 pin, female) to
12V car battery. (Note, for DTM meteo sensor e.g. the additional cable 734 698 is required.)
6.8 Power cables
For power cables please refer to section “
”.
6.9 Radio modem / mobile phones cables
”.
51
For transmitting data
7.1 Satelline Radio Modem, Radio Antennas and Accessories
Satelline Radio Modems
733 275
733 276
738 272
738 273
738 274
738 275
738 276
GFU14-0, Satelline 3AS radio modem (433.525 MHz, 25.0 kHz channel spacing, 0.5 W) already integrated into housing, fits on side of GPS Receiver. (User manual and CE-
Declaration of Conformity included).
GFU14-1, Satelline 3AS radio modem (406.425 MHz, 25.0 kHz channel spacing, 1.0 W) already integrated into housing, fits on side of GPS Receiver. (User manual and CE-
Declaration of Conformity included).
GFU14-2, Satelline 3AS radio modem (445.000 MHz, 12.5 kHz channel spacing, 1.0 W) already integrated into housing, fits on side of GPS Receiver. (User manual and CE-
Declaration of Conformity included).
GFU14-3, Satelline 3AS radio modem (443.000 MHz, 12.5 kHz channel spacing, 1.0 W) already integrated into housing, fits on side of GPS Receiver. (User manual and CE-
Declaration of Conformity included).
GFU14-4, Satelline 3AS radio modem (440.550 MHz, 25.0 kHz channel spacing, 0.5 W) already integrated into housing, fits on side of GPS Receiver. (User manual and CE-
Declaration of Conformity included).
GFU14-5, Satelline 3AS radio modem (458.150 MHz, 12.5 kHz channel spacing, 1.0 W) already integrated into housing, fits on side of GPS Receiver. (User manual and CE-
Declaration of Conformity included).
GFU14-6, Satelline 3AS radio modem (439.8625 MHz, 12.5 kHz channel spacing, 1.0 W) already integrated into housing, fits on side of GPS Receiver. (User manual and CE-
Declaration of Conformity included).
Select according to frequency of radio modem
639 964
667 243
GAT1, Gainflex radio antenna, frequency range 400-435MHz.
GAT2, Gainflex radio antenna, frequency range 435-470MHz.
Programming Cable for Satelline Radio Modem
733 297 GEV171, 1.8m cable to program, the Satelline 3AS radio modem inside the GFU14 housing.
7.2 TCPS27 Radio Modem and Accessories
TCPS27 Radio Modems
734 161
734 162
TCPS27 B, radio modem (base), with antenna, user manual. Used as radio modem for
TPS1200 (frequency range 2400 - 2483 Mhz).
TCPS27 R, radio modem (remote), with antenna, user manual. Used as external radio for
PC (frequency range 2400 - 2483 MHz).
Cables for TCPS27 Radio Modems
734 697
771 057
734 699
---
GEV186, Y-cable, connects TCPS27 to TPS/1000/1100/1200 and external battery, 1.8m.
GEV236, Y-cable, connects TM30/TS30 to TCPS radio and external battery, 2m.
GEV188, Y-cable, connects TCPS27 to PC (9-pin RS232 serial) and external battery, 1.8m.
Coaxial cable, connects antenna to TCPS27
Important Use the TCPS27 ConfigTool from the CD to set the correct baud rate and link number.
Enable the RTS mode in the GeoMoS Monitor software.
52
7.3 Mobile Phones and Accessories
750 242
667 237
733 297
GFU24, Housing with Siemens MC75 GSM/GPRS Module (Quad-Band GSM
850/900/1800/1900 MHz).
Antenna for 900/1800 MHz mobile network.
GEV171, 1.8m cable to program, the Satelline 3AS radio modem inside the GFU14 housing. Also used to connect GFU17 to PC.
53
Other Accessories
8.1 Switchbox
Essential tool for permanent monitoring, supports cold boot for TPS
744 793
772 630
Switchbox with a 2.0m cable for TPS1000/ TPS 1100/ TPS 1200 (Lemo 0) and GeoMoS.
GDZ 68, Switchbox with a 2.0m cable for TM30/TS30 (Lemo 1) and
GeoMoS
54
Third party devices
Leica Geosystems tested and uses the following devices in local Leica monitoring solutions:
9.1 RS232/RS485 converter
I-7520 RS232 to RS485 converter for Nivel220 sensors http://www.icpdas.com
http://www.icpdas.com/products/Remote_IO/i-7000/i-7520.htm
This is a product of ICP DAS Co.
9.2 RS232/Ethernet converter
Model 58631,
Model 58633
1 serial port
3 serial ports
RS232 to Ethernet converter for total stations and Nivel210 sensors http://www.wut.de
http://www.wut.de/e-58631-ww-daus-000.php
http://www.wut.de/e-58633-ww-daus-000.php
This is a product of Wiesemann & Theis GmbH.
MOXA5110
1 serial port
RS232 to Ethernet converter for total stations and Nivel210 sensors http://www.moxa.com
http://www.moxa.com/Product/NPort_5110.htm
Use the –T models for outdoor installations
This is a product of Moxa Inc.
9.3 Wireless modem
NB2210 The NB2210 connects Ethernet enabled equipment to the internet over a mobile network (GSM/GPRS/EDGE) http://www.netmodule.com/en/ http://www.netmodule.com/en/products/nb/nb2210.aspx
This is a product of NetModule Inc.
55
9.3.1 Remote Setup of a Total Station with a Wireless Modem (e.g. NB2210)
Internet
734 698
759 257
664 662
757 129
764 824
439 038
NB
749 279
744 793
772 630
Mini Adapter
Select Total Station
664 662
757 129
764 824
TCA2003, 0.5"(0.15mgon) automatic precision total station, with laser plummet, 2 control panels, accessories, user manual and container.
TM30 0.5”, 0.15gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.
TM30 1”, 0.3gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.
Select Cables and Switchbox
744 793 Switchbox with cable 2.0m for TPS/1000/1100/1200 and GeoMoS. Supports cold boot for TPS
772 630
734 698
759 257
Mini adapter
Gender changer
(important 24/7 hours/day monitoring).
GDZ 68, Switchbox with a 2.0m cable for TM30/TS30 (Lemo 1) and GeoMoS. Supports cold boot for
TPS (important 24/7 hours/day monitoring).
GEV187, Y-cable, connects TPS/1000/1100/1200 to PC (9-pin RS232 serial) and external battery, 2.0m.
GEV220, Y-cable, connects TM30/TS30 to PC (9-pin RS232 serial) and external battery, 2.0m.
Null modem, DB9 male to DB9 female. Refer to “ 9.6.2 Mini adapter ”.
Gender changer, DB9 male to DB9 male. Refer to “
”.
Select Power
439 038
749 279
GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.
GEV208, Power supply unit for TPS, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to TPS.
Select power cords for 12V power supply unit 749 279. Refer to “
Select Wirless Modem
NB2210 The NB2210 connects Ethernet enabled equipment to the internet over a mobile network
(GSM/GPRS/EDGE). Refer to “
”.
Select Software
GeoMoS Monitor / Analyzer
”
56
9.4 Digital IO card
Web IO 2x
Digital Input, 2x
Digital Output
The Web IO (2x Digital Input, 2x Digital Output) connects digital input and output ports of industrial 24V technology to the network .
http://www.wut.de
http://www.wut.de/e-57633-ww-daus-000.php
This is a product of Wiesemann & Theis GmbH.
9.5 Datalogger
CR1000
Multiplexer
9.6 Wireless Ethernet Radio
ELPRO 805U-E
CR1000 MEASUREMENT AND CONTROL MODULE C/W CR1000WP
AM16/32A 16/32 CHANNEL RELAY MULTIPLEXER C/W SPARK GAPS http://www.campbellsci.com/cr1000 http://www.campbellsci.com/index.cfm
This is a product of Campbell Scientific Ltd.
The ELPRO 805U connects serial or Ethernet devices by industrial wireless radio modems. http://www.elprotech.com/ http://www.elprotech.com/index.cfm?content=280
This is a product of ELPRO Technologies.
57
9.6.1 Remote Setup of a Total Station with Radio (ELPRO 805U-E)
722 409
ELPRO antenna
748 488
ELPRO Mini Adapter
ELPRO antenna
Ethernet cable
ELPRO
734 698
759 257
664 662
757 129
764 824
439 038
748 488
722 409
749 279
744 793
772 630
Select Total Station
664 662
757 129
764 824
TCA2003, 0.5"(0.15mgon) automatic precision total station, with laser plummet, 2 control panels, accessories, user manual and container.
TM30 0.5”, 0.15gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.
TM30 1”, 0.3gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.
Select Cables and Switchbox
744 793
772 630
734 698
759 257
748 488
Switchbox with cable 2.0m for TPS/1000/1100/1200 and GeoMoS. Supports cold boot for TPS
(important 24/7 hours/day monitoring).
GDZ 68, Switchbox with a 2.0m cable for TM30/TS30 (Lemo 1) and GeoMoS. Supports cold boot for
TPS (important 24/7 hours/day monitoring).
GEV187, Y-cable, connects TPS/1000/1100/1200 to PC (9-pin RS232 serial) and external battery, 2.0m.
GEV220, Y-cable, connects TM30/TS30 to PC (9-pin RS232 serial) and external battery, 2.0m.
0.8m power supply cable, connects power supply unit 722 409 to RS232/RS485 converter, Lemo-0 to
2 wires to terminal strip.
Null modem, DB9 male to DB9 male. Refer to “
”. Mini adapter
Ethernet
cable
Select Radio Modem
ELPRO Interconnect
Select Power
439 038
749 279
722 409
GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.
GEV208, Power supply unit for TPS 2003, for indoor use only, input 100V-240VAC 50-60HZ, output
12VCD, cable with 5-pin Lemo to connect to TPS.
Power supply unit, for indoor use only, input 100V-240VAC 50-60HZ, output 12VDC, cable with 5-pin
Lemo.
58
Select power cords for 12V power supply unit 722 409 and 749 279. Refer to “ 5 Power supply
”.
Select Software
GeoMoS Monitor / Analyzer
”
59
9.6.2 Remote Setup of a GMX902 with Radio (ELPRO 805U-E)
Ethernet cable
748 488
ELPRO antenna
ELPRO antenna
ELPRO
ELPRO
733 280
Mini Adapter
722 409
748 488 758 600
722 409
722 409
Select Receiver
758 600 GMX902 GG, GNSS Dual Frequency Receiver for Monitoring Applications.
Select Cables
733 280
748 488
GEV160, 2.8m Data transfer cable. Connects GPS1200 receiver Ports 1, 2 and 3, RX1220 or GMX902 to
PC for data transfer, firmware upload etc. Lemo 8 Pin to 9 pin RS232 female serial connector.
0.8m power supply cable, connects power supply unit 722 409 to RS232/RS485 converter, Lemo-0 to
2 wires to terminal strip.
Null modem, DB9 male to DB9 male. Refer to “
”. Mini adapter
Ethernet cable
Select Antenna
747 958
766 714
755 267
765 733
AX1203+ GNSS, GPS/GLONASS/Galileo Triple Frequency Antenna for all GRX1200 Series and GRX1200+
Series receivers.
AX1202 GG, Dual Frequency Antenna for GX1230 GG and GRX 1200 GG Pro Receiver
AT504 GG, GPS/GLONASS dual-frequency choke-ring antenna for GPS/GLONASS receivers. Dorne-
Margolin antenna element, JPL design. Conforms to IGS "Typ T" specification for GPS antennas. For
GX1220 / 1230, GRX1200 and GMX902 Receivers.
AR25, GNSS choke ring antenna for GPS/GLONASS/Galileo/Compass receivers. Includes L-Band signals.
Dorne-Margolin antenna element.
GVP601, Weather-protection radome for AT504 choke ring antenna. 667 140
765 734 GVP653, Weather-protection radome AR25 choke ring antenna.
Select Antenna Cables
632 372
632 390
Antenna cable, 10 m
Antenna cable, 30 m
60
Select Radio Modem
ELPRO Interconnect
Select Power
722 409 Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.
Select power cords for 12V power supply unit 722 409. Refer to “
Select Software
Leica GNSS Spider
Refer to “ 4.2.4 GNSS Spider ”
Optional Software
GeoMoS Monitor / Analyzer
Leica GNSS QC
”
Note: If you connect more than one GNSS receiver to GeoMoS to use for monitoring we recommend GNSS connection to the Leica Spider software. GeoMoS supports an interface to Leica GNSS Spider software (order GNSS Spider and accessories separately)
61
9.6.3 Remote Setup of a GMX901 with Radio (ELPRO 805U-E)
722 409
755 231
743 389
Ethernet cable
ELPRO antenna
ELPRO
ELPRO antenna
722 409
748 488
748 488
ELPRO
Mini Adapter
722 409
Select Receiver
755 231
Select Cables
743 389
748 488
GMX901, GPS Smart Antenna for Monitoring Applications
GEV197, Y-Cable, 2.8m, GMX901 to RS232 and external Leica power supply.
0.8m power supply cable, connects power supply unit 722 409 to RS232/RS485 converter, Lemo-0 to
2 wires to terminal strip.
Null modem, DB9 male to DB9 male. Refer to “
”. Mini adapter
Ethernet
cable
Select Radio Modem
ELPRO Interconnect
Select Power
439 038
722 409
GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.
Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.
Select power cords for 12V power supply unit 722 409. Refer to “
Select Software
Leica GNSS Spider
Refer to “ 4.2.4 GNSS Spider ”
Optional Software
GeoMoS Monitor / Analyzer
Leica GNSS QC
”
62
9.6.4 Remote Setup of a Nivel210 with Radio (ELPRO 805U-E)
Ethernet cable
ELPRO antenna
ELPRO
576 198
ELPRO antenna
802 902
ELPRO
Mini Adapter
748 488
722 409
748 335
722 409
Select Sensor
576 198
Select Cables
748 335
802 902
748 488
Mini adapter
Ethernet cable
Select Radio Modem
NIVEL210, inclination sensor with RS232 interface
GEV204, Power supply-cab.f. NIVEL210/230
Cable, PC- NIVEL210, (Lemo-RS232), 1m
0.8m power supply cable, connects power supply unit 722 409 to RS232/RS485 converter, Lemo-0 to
2 wires to terminal strip.
Null modem, DB9 male to DB9 male. Refer to “ 9.7.2 Mini adapter ”.
ELPRO Interconnect
Select Power
722 409 Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.
Select power cords for 12V power supply unit 722 409. Refer to “
Select Software
GeoMoS Monitor / Analyzer
GNSS QC
”
Important Use the NivelTool software from the CD to set the correct Nivel ID and baud rate.
63
9.6.5 Remote Setup of multiple Nivel220 with Radio (ELPRO 805U-E)
Ethernet cable
ELPRO antenna
ELPRO
748 488
567 199
722 409
567 199
ELPRO antenna
ELPRO
748 498
567 199
802 906 or
802 907
802 906 or
802 907
575 869
748 488
722 409
Select Sensor
576 199 NIVEL220, inclination sensor with R4852 interface
Select Cables
748 488
748 498
802 906
802 907
575 869
Ethernet cable
Select Radio Modem
0.8m power supply cable, connects power supply unit 722 409 to RS232/RS485 converter, Lemo-0 to
2 wires to terminal strip.
1.8m communication cable, connects Nivel220 to RS232/RS485 converter, Lemo-0 to 4 wires to terminal strip.
5.0m connection cable RS485. Connects two Nivel220 sensor ports 1 or 2, Lemo-0 to Lemo-0.
20.0m connection cable RS485. Connects two Nivel220 sensor ports 1 or 2, Lemo-0 to Lemo-0.
Terminator 120 Ohm, for RS485 Bus
ELPRO Interconnect
Select Power
722 409 Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.
Select power cords for 12V power supply unit 722 409. Refer to “
Select Software
Important
GeoMoS Monitor / Analyzer
GNSS QC
”
Use the NivelTool software from the CD to set the correct Nivel ID and baud rate.
64
9.7 Accessories
9.7.1 Cables
9.7.2 Mini adapter
RS232 cable or so-called DB9 cable
Ethernet cable
CAT6
Shielded cable
Terminal strip
Mount in a box
Null modem or
RS232 reverser
Specification
A null modem (or RS232 reverser) reroutes wiring.
A null modem crosses pins 2 and 3, so that pin 2 on one side is connected to pin 3 on the other.
Gender changer A gender changer is a small hardware device or adapter that is used to correct the connector mismatches of cables.
65
Leica Geosystems AG
Heerbrugg, Switzerland www.leica-geosystems.com
Whether you monitor the movement of a volcanic slope, the structure of a long bridge or track the settlement of a dam; whether you measure, analyse and manage the structures of natural or man-made objects: the monitoring systems by Leica Geosystems provide you with the right solution for every application.
Our solutions provide reliable, precise data acquisition, advanced processing, sophisticated analysis and secure data transmission.
Using standard interfaces, open architectures and scaleable platforms, the solutions are customizable to meet individual requirements – for permanent and temporary installations, for single sites and monitoring networks.
When it has to be right.
Illustrations, descriptions and technical specifications are not binding and may change.
Printed in Switzerland – Copyright Leica Geosystems AG, Heerbrugg, Switzerland, 200 8.
729323en –
V1.09 – INT
advertisement
Related manuals
advertisement