ELPRO 805U-E User manual

Add to My manuals
66 Pages

advertisement

ELPRO 805U-E User manual | Manualzz

Structural Monitoring

Equipment List

2

Overview

GeoMoS Modules

1.1 GeoMoS Monitor (758 749) ....................................................................................................................6

1.1.1 GeoMoS Monitor Option 1 (758 751) ........................................................................................ 6

1.1.2 GeoMoS Monitor Option 2 (758 752) ........................................................................................ 6

1.1.3 GeoMoS Monitor Option 3 (772 767) ........................................................................................ 6

1.2 Sensor License (758 750) .......................................................................................................................7

1.2.1 Sensor Licenses – Examples.......................................................................................................7

1.3 GeoMoS Analyzer (723 366) ...................................................................................................................8

1.3.2 GeoMoS Analyzer Option 1 (758 753) ....................................................................................... 8

1.4 GeoMoS Demo (724 933) .......................................................................................................................9

1.5 GeoMoS Web (5 001 892).......................................................................................................................9

1.6 GeoMoS Adjustment (772 767).............................................................................................................10

1.7 Leica CrossCheck...................................................................................................................................10

GeoMoS Maintenance

2.1 Customer Care Packages (CCP)..............................................................................................................12

2.2 Other Services.......................................................................................................................................12

Monitoring Systems

3.1 Overview...............................................................................................................................................13

3.2 Setup of a Total Station with direct serial .............................................................................................15

3.3 Remote Setup of a Total Station with Radio (GFU14)............................................................................16

3.4 Remote Setup of a Total Station with Radio (TCPS27) ..........................................................................18

3.5 Setup of a MC75 ...................................................................................................................................19

3.6 Setup of real-time GNSS with GMX902 Sensors ....................................................................................20

3.7 Setup of post processing GNSS with GRX1200Pro Sensors ...................................................................22

3.8 Setup of a Meteo Sensor ......................................................................................................................24

3.9 Setup of a Level ....................................................................................................................................25

3.10 Remote Setup of a GMX902 Sensor with Radio (GFU-14) ...................................................................26

3.11 Setup of a GNSS Sensor co-located with a Total Station .....................................................................28

3.12 Setup of a GMX901 Sensor with standard cables ................................................................................30

3.13 Setup of a GMX901 Sensor with custom wired cables.........................................................................31

3.14 Remote Setup of a GMX901 Sensor with Radio (GFU-14) ...................................................................32

3.15 Setup of a Nivel210 (RS232)...............................................................................................................34

3.16 Setup of a Nivel210 with GRX1200Pro Series......................................................................................35

3.17 Setup of a Nivel220 (RS485) with Leica cables ...................................................................................37

3.18 Setup of a Nivel220 (RS485) with long cables.....................................................................................38

Sensors

4.1 TPS Sensors ..........................................................................................................................................41

4.1.1 Supported Sensors .................................................................................................................. 41

4.1.2 Supported Reflectors............................................................................................................... 42

4.1.3 Tribrachs ................................................................................................................................. 42

4.1.4 Other TPS Accessories ............................................................................................................. 42

4.2 GNSS Sensors .......................................................................................................................................43

4.2.1 Supported Sensors .................................................................................................................. 43

4.2.2 Antennas................................................................................................................................. 44

4.2.3 GNSS Accessories .................................................................................................................... 44

4.2.4 GNSS Spider ............................................................................................................................ 45

4.2.5 GNSS QC.................................................................................................................................. 45

4.3 Levels....................................................................................................................................................46

4.3.1 Supported Sensors .................................................................................................................. 46

4.3.2 DNA Staffs .............................................................................................................................. 46

3

4.3.3 Sprinter Staffs ......................................................................................................................... 46

4.4 Other Sensors.......................................................................................................................................47

4.4.1 Inclination Sensors .................................................................................................................. 47

4.4.2 Meteo Sensors ........................................................................................................................ 47

Power Supply

5.1 Continuous 12V Power supply for GPS1200 and NIVEL sensors .............................................................48

5.2 Continuous 12V Power supply for TPS sensors......................................................................................48

Cables

6.1 Total station cables...............................................................................................................................49

6.2 GPS1200 / GMX902 cables ....................................................................................................................49

6.3 GMX901 cables .....................................................................................................................................49

6.4 Antenna cables .....................................................................................................................................50

6.5 Level cables ..........................................................................................................................................50

6.6 Nivel210 / Nivel220 cables ....................................................................................................................50

6.7 Meteo sensor cables .............................................................................................................................51

6.8 Power cables.........................................................................................................................................51

6.9 Radio modem / mobile phones cables ...................................................................................................51

For transmitting data

7.1 Satelline Radio Modem, Radio Antennas and Accessories .....................................................................52

7.2 TCPS27 Radio Modem and Accessories..................................................................................................52

7.3 Mobile Phones and Accessories.............................................................................................................53

Accessories

8.1 Switchbox .............................................................................................................................................54

Third party

9.1 RS232/RS485 converter ........................................................................................................................55

9.2 RS232/Ethernet converter.....................................................................................................................55

9.3 Wireless modem ...................................................................................................................................55

9.3.1 Remote Setup of a Total Station with a Wireless Modem (e.g. NB2210).................................. 56

9.4 Digital IO card .......................................................................................................................................57

9.5 Datalogger ............................................................................................................................................57

9.6 Wireless Ethernet Radio ........................................................................................................................57

9.6.1 Remote Setup of a Total Station with Radio (ELPRO 805U-E) .................................................. 58

9.6.2 Remote Setup of a GMX902 with Radio (ELPRO 805U-E)......................................................... 60

9.6.3 Remote Setup of a GMX901 with Radio (ELPRO 805U-E)......................................................... 62

9.6.4 Remote Setup of a Nivel210 with Radio (ELPRO 805U-E) ........................................................ 63

9.6.5 Remote Setup of multiple Nivel220 with Radio (ELPRO 805U-E).............................................. 64

9.7 Accessories ...........................................................................................................................................65

9.7.1 Cables ..................................................................................................................................... 65

9.7.2 Mini adapter ............................................................................................................................ 65

4

GeoMoS Modules

GeoMoS – Geodetic and geotechnical Monitoring Solutions

GeoMoS comprises the following modules:

Leica GeoMoS User Versions

Demo

Version

(1 year)

Article Name

Article Number (SAP)

CD-ROM included

USB Dongle (default)

Parallel Dongle (optional)

Sensor License

Monitor Option 1 (Computation)

Monitor Option 2 (Limit checks/Messaging)

Monitor Option 3 (Export Service for

GeoMoS Adjustment)

Analyzer Option 1 (TPS Post-Processing)

Quarterly Subscription Per Point

Administration Fee

723 367

734 713

734 712

758 750

758 751

758 752

773 056

758 753

5 302 475

5 001 893

758 749 723 366 5001892 772 767 724 933 z z z z z z z z

}

}

}

}

}

}

} z z z

} z

}

─ z z

z

Legend z

}

included: automatically, not removable optional not available

Software protection keys

734 712

734 713

Upgrade

748 840

CCP

Software protection key (parallel)

Software protection key (USB)

Upgrade from GeoMoS Version 1.55, 1.6, 2.0 and 2.1 to Version 5.0 (inclusive Upgrade from existing GeoMoS Options to new GeoMoS 5.0 Options).

Upgrade from GeoMoS Version 3.0, 3.1, 4.0, 4.1 to Version 5.0 (inclusive Upgrade from all Options).

5

1.1 GeoMoS Monitor (758 749)

GeoMoS Monitor is the monitoring software for the normal use of the customer. The customer can collect and store data.

Additional options can be added later.

ƒ Connection to sensors (serial or TCP/IP) with valid Sensor Licenses

ƒ Project management

ƒ User levels

ƒ Learn points

ƒ Manual stand point coordinate determination with Free Station,

Distance Intersection or GNSS Update

ƒ Automatic measurements with various options

ƒ Blunder tolerance checks on raw data

ƒ Information about the current system and measurement status

ƒ Calculation of GNSS displacements and daily average results

ƒ Automatic database export

ƒ SQL Server 2005 Express database included

A number of options are available for the use together with GeoMoS Monitor:

758 751

758 752

773 056

GeoMoS Monitor Option 1 (Computation)

GeoMoS Monitor Option 2 (Limit checks and Messaging)

GeoMoS Monitor Option 3 (Export Service to GeoMoS Adjustment)

Note: Sensors can only connected to GeoMoS Monitor, if the required amount of sensor licenses has been ordered

also. Refer to the section “ 1.2 Sensor License

” for more detail.

Leica GeoMoS makes use of the Microsoft SQL database. With Leica GeoMoS the free version Microsoft SQL Server 2005 Express is provided and will be installed, if no SQL server is available.

1.1.1 GeoMoS Monitor Option 1 (758 751)

Computation ƒ Automatic total station stand point setup with different methods (Free

Station, Distance Intersection or GNSS Update)

ƒ Calculation of any total station results including coordinates, displacements, profiles, distance reduction

ƒ Calculation of any total station correction with Free Station, Distance

Intersection, Orientation, PPM and Vz Correction groups and associated point group properties

ƒ Calculation of daily average results for total stations

ƒ Computation of virtual sensors with constants, mathematical functions and/or logic operators.

1.1.2 GeoMoS Monitor Option 2 (758 752)

Limit checks and Messaging ƒ Automatic computation of limit checks

ƒ Multiple levels of limit checks (yellow, orange, red)

ƒ Limit Level 1, 2 and 3 can be assigned independent actions

ƒ Four different types of limit check computation (absolute, short time, long time and regression)

ƒ Allows emails and SMS to be sent, applications to be run, the database to be queried and digital outputs to be set when defined messages are generated by the system

1.1.3 GeoMoS Monitor Option 3 (773 056)

Export Service for GeoMoS ƒ Manual and automatic GeoMoS data export in XML format

Adjustment

6

1.2 Sensor License (758 750)

The sensor license concept means that the software scales with the number and type of sensors you have connected. Additional sensor licenses can easily be added later should your needs change.

For each sensor you need to order a special amount of Sensor Licenses (Art. No. 758 750). The required amount of sensor licenses per sensor is listed below:

* Sensor License

Amount required per sensor

TPS Sensor 30

10 GNSS Sensor (NMEA)

Connection to a GNSS Spider Site Server with all

Spider RT Positioning Products

Connection to a GNSS Spider Site Server with all

Spider PP Positioning Products

Nivel200 Sensor

Digital Level

10

10

3

3

Temperature / Pressure Sensor (DTM STS) 1

Geotechnical Sensor connected via Campbell

Scientific Datalogger

1

Note that each sensor requires sensor licenses even though the sensor is connected with a bus system (Nivel220) or Campbell

Scientific datalogger (geotechnical sensor) to GeoMoS.

For more information about connectable sensors offering with GeoMoS Monitor please contact your local Leica Geosystems organization or distribution partner.

1.2.1 Sensor Licenses – Examples

Example 1:

Your customer wants to use a total station and a temperature sensor for monitoring with GeoMoS.

How many Sensor Licenses must he order?

1x TPS Sensor

1x Temperature Sensor (DTM STS)

30

01

Sensor Licenses (Art. No. 758 750) 31

Example 2:

Your customer wants to use a Nivel220 bus system with five sensors for monitoring with GeoMoS.

How many Sensor Licenses must he order?

5x Nivel200 Sensor

Sensor Licenses (Art. No. 758 750)

1x TPS Sensor

1x Connection to a GNSS Spider Site Server with all Spider RT

Positioning Products

5 x 3

15

Example 3:

Your customer wants to use a combined TPS/GNSS monitoring system with a total station and GNSS Spider RT positioning products for monitoring with GeoMoS. Therefore five GNSS sensors are connected as passive LB2 and two GNSS sensors as active data streams to GNSS Spider.

How many Sensor Licenses must he order?

30

10

Sensor Licenses (Art. No. 758 750) 40

Note: The Spider RT Positioning Products computation requires additional Spider Positioning Site Licenses (Art. No. 744 912).

Refer to “ 4.2.4 GNSS Spider ”.

7

Example 4:

Your customer wants to use a combined TPS/GNSS monitoring system with a total station and GNSS Spider RT and PP positioning products for monitoring with GeoMoS. The customer has 12 GNSS sensors are connected to GNSS Spider.

How many Sensor Licenses must he order?

1x TPS Sensor

1x Connection to a GNSS Spider Site Server with all Spider RT

Positioning Products

1x Connection to a GNSS Spider Site Server with all Spider PP

Positioning Products

30

10

10

Sensor Licenses (Art. No. 758 750) 50

Note: The Spider RT and PP Positioning Products computation requires additional Spider Positioning Site Licenses (Art. No. 744

912) and Spider File Products Service (FPS) option (Art. No. 744 904). Refer to “ 4.2.4 GNSS Spider

”.

Example 5:

Your customer wants to use a Campbell Scientific Datalogger with different geotechnical sensors for monitoring with GeoMoS.

How many Sensor Licenses must he order?

Setup A 1 sensor measuring one value type (e.g. wind speed)

Setup B 1 sensor measuring three value types (e.g. temperature, pressure and humidity)

Setup C 1 sensor measuring one value type (e.g. wind speed) and 1 sensor measuring one value type (e.g. rain fall)

Setup D 5 sensors measuring three value types (e.g. temperature, pressure and humidity)

01

03

02

15

1.3 GeoMoS Analyzer (723 366)

GeoMoS Analyzer is an analysis tool that can be used to view data collected by any GeoMoS Monitor.

Note: For online analysis using GeoMoS Analyzer at a remote location there needs to be continual connection between GeoMoS

Monitor and GeoMoS Analyzer computers.

ƒ Graphical and numerical visualization of results

ƒ More than one installation of Analyzer may access the data and do analysis simultaneously

ƒ Project management

ƒ User levels

ƒ Outlier detection algorithm

ƒ Set results invalid/valid

ƒ Enter comments

ƒ Customizable graphics

ƒ Customizable reports with filter and search mechanism

ƒ Manual database import and export

ƒ Export to other systems e.g. ASCII, DXF and BMP

ƒ SQL Server 2005 Express database included

A number of options are available for use together with GeoMoS Analyzer:

758 753 GeoMoS Analyzer Option 1 (TPS Post-Processing)

Leica GeoMoS makes use of the Microsoft SQL database. With Leica GeoMoS the free version Microsoft SQL Server 2005 Express is provided and will be installed, if no SQL server is available.

1.3.2 GeoMoS Analyzer Option 1 (758 753)

TPS post processing ƒ Re-processing of the coordinate system, distance reduction, meteo model and all values modified in the Data Editor

ƒ Data Editor to modify additive constants, reflector heights, temperature and pressure

ƒ Re-processing of the profile directions, instrument height and null coordinate together with GeoMoS Monitor

8

1.4 GeoMoS Demo (724 933)

GeoMoS Demo is only for demonstration purposes to sell the product. GeoMoS Demo is not for commercial sale. GeoMoS Demo has the same functionality as GeoMoS Monitor and GeoMoS Analyzer but cannot be used for permanent monitoring. The automatic measurement will only run for a limited time (TPS Sensor measurements = 100, geotechnical measurements = 500).

Note: GeoMoS Demo does not include Leica GeoMoS Adjustment and GeoMoS Monitor Option 3

1.5 GeoMoS Web (5 001 892)

Leica GeoMoS Web is a web based service for visualization and analysis of monitoring data collected by GeoMoS Monitor.

ƒ Easy access through standard web browsers

ƒ Graphical and visualization of monitoring data

ƒ Overview and site maps

ƒ Timeline, scatter and vector graphs

ƒ View webcam images and web image

ƒ User levels (admin, viewer)

ƒ Customizable graphics

ƒ Save raw data to comma separated files

ƒ Personalized and secure data access

ƒ No need to maintain IT infrastructure and software

ƒ Physical and electronic security of data

ƒ Protection against misusage

ƒ Easy translation based on XML files

The Leica GeoMoS Web service is composed of:

ƒ an one time only Setup Fee (Art. No. 5 001 892) and

ƒ a quarterly Subscription (Art. No. 5 302 475) that scales with the size of the monitoring installation.

Leica GeoMoS Web

5 001 892 GeoMoS Web Setup Fee For the initial configuration of the service. Once only.

5 302 475

GeoMoS Web Quarterly

Subscription Per Point

For access to the web service for a period of three months

(90 days). One article is required for each monitoring point to be shown in the web. A minimum of 5 X Article 5 302 475 is required.

Billing

ƒ An invoice will be sent each month or quarter for the amount of Quarterly Subscription Per Point’s that were ordered.

ƒ The service is paid per billing period (month / quarter).

Service Change Requests

The amount of Quarterly Subscription Per Point’s of the Leica GeoMoS Web service can be changed at a month’s notice for the next billing period. An administration fee (Article 5 001 893) of 200.- CHF is incurred each time the number of points is increased. It is not possible to decrease the number of points.

Cancellation

ƒ The Leica GeoMoS Web service can be cancelled with a month’s notice for the next billing period.

ƒ The cancellation notice must be given in written form.

Customer Care Package License

Leica GeoMoS Web is a service that requires no extra CCP License.

9

1.6 GeoMoS Adjustment (772 767)

Leica GeoMoS Adjustment is an add-on analysis software that can be used to compute network adjustment and deformation analysis data collected by any GeoMoS Monitor.

ƒ Manual and automatic import of GeoMoS XML files

ƒ Network adjustment computation as minimal constraint network, reference points as fixed or absolute fixed

ƒ Automatic outlier detection and removal

ƒ Deformation analysis based on the two-step method

ƒ Detect stable and unstable reference points

ƒ Combination of total stations and/or GPS/GNSS

ƒ Numerical and graphical analysis of the network adjustment and deformation analysis data

ƒ Statistically qualified data with precision and reliability

ƒ Display the magnitude, precision pattern and statistically significance of movements

ƒ Display unstable reference points

ƒ Compare the results of different measurement epochs

ƒ Simulate the mathematical geometry simulation to optimize the network accuracy and reliability

Extended Analysis Service

Consultation, training and data analysis services are available from our partner company

Technet GmbH. Technet’s highly qualified engineers have over 15 years of experience in high precision deformation surveys, network adjustment and deformation analysis in a wide range of projects.

Notes:

ƒ GeoMoS Monitor Option 3 (773 056) is required to export data for GeoMoS Adjustment. The GeoMoS Monitor Option 3 bit must be available on the dongle where GeoMoS Monitor is running.

ƒ GeoMoS Demo (724 933) does not include Leica GeoMoS Adjustment

1.7 Leica CrossCheck

Leica CrossCheck is a web based service for GPS/GNSS reference network coordinate calculation, integrity monitoring and deformation monitoring.

Monitoring Service

The Monitoring Service provides detection and warning of antenna movements in near real time for networks of

GNSS reference stations or monitoring receivers. Site coordinates are calculated at a user defined interval. The solution is tailored to the needs of the customers network/project, including the processing interval, processing strategy, coordinate datum, limit checks and content of the secure online web service. An email messaging service is offered to provide warning when a significant movement occurs.

The Monitoring Service consists of a one-time setup fee and then a quarterly subscription comprised of a base fee and a per site fee.

Leica GeoMoS CrossCheck for monitoring

5 002 094

5 302 771

5 302 772

CrossCheck Monitoring

Setup Fee

CrossCheck Quarterly

Subscription Base Fee

CrossCheck Quarterly

Subscription Per Site

For the initial configuration of the service. Once only.

For access to the web service for a period of three months

(90 days). One article is required for each web service.

For access to the web service for a period of three months

(90 days). One article is required for each monitoring receiver.

10

Invoicing

ƒ The initial setup fee will be invoiced after sending the entitlement number (see below)

ƒ The Single Computation Service will be invoiced once the service has been completed

ƒ The Monitoring Service will be invoiced quarterly at the end of the period, if not cancelled (see below)

Monitoring Service Change Requests

The amount of Quarterly Subscription Per Site of the Leica CrossCheck Monitoring Service can be changed at a month’s notice for the next billing period. An administration fee (Article 5 002 120) is incurred each time the number of points is increased or decreased.

Cancellation

ƒ The Leica CrossCheck Monitoring Service can be cancelled with a month’s notice for the next quarter.

ƒ The cancellation notice must be given in written form.

11

GeoMoS Maintenance

2.1 Customer Care Packages (CCP)

A powerful and competent worldwide service and support network backs up Leica GeoMoS.

ƒ Leica GeoMoS Monitor

ƒ Leica GeoMoS Analyzer

ƒ Leica GeoMoS Adjustment

Customer Care Packages (CCPs) provide you access to a world-class support & service infrastructure and ensure your systems are being kept up to date.

A wide selection of comprehensive Customer Care Packages is available bundling Hardware

Maintenance, Software Maintenance, Customer Support and Extended Warranty. For more information about the CCP offering in your country please contact your local Leica Geosystems organization or distribution partner.

The Customer Care Packages articles are available worldwide and can be ordered for end-users together with new software.

Select CCP

6000933

6000934

6000935

1 year GeoMoS Basic CCP

2 year GeoMoS Basic CCP

3 year GeoMoS Basic CCP

Select CCP for Distribution Partner

6000936

6000937

6000938

1 year GeoMoS Distr. Basic CCP

2 year GeoMoS Distr. Basic CCP

3 year GeoMoS Distr. Basic CCP

2.2 Other Services

The following services are available on request at daily rates.

Training at customer site

Customizing

Information on article numbers are available on request.

12

Monitoring systems

3.1 Overview

Each monitoring project has specific measurement and accuracy requirements. If you are going to prepare a monitoring project or plan to offer a quotation for a monitoring tender, the following five sections have to considered:

1. Sensors ƒ

ƒ

Total stations, prisms and mounting

GNSS Sensors, antennas and mounting

ƒ Inclination Sensors, shelters and mounting

ƒ Meteo Sensors, mounting

ƒ Other Sensors

2. PC and Software

3. Power

4. Communication

5. Miscellaneous

Robust PC with serial ports and GeoMoS, GeoMoS Web, GNSS Spider or GNSS QC.

Reliable power source with backup

ƒ direct power or

ƒ separate units or

ƒ solar panels

Cables, radio modems

ƒ Measurement hut to protect the total station and PC from the elements for example rain, sun, dust, snow

ƒ Pillars and monumentation

ƒ Climate control system (avoid temperature expansion, moisture, condensation and uneven heating of the instrument)

ƒ Security

ƒ Access (physical and remote)

Combine Leica software, geodetic, geotechnical and meteorological sensors to match the needs of your monitoring challenge.

Basic examples are given in the next section to provide an idea of monitoring setups and options.

3.2 Setup of a Total Station with direct serial ...................................................................................... 15

3.3 Remote Setup of a Total Station with Radio (GFU14)...................................................................... 16

3.4 Remote Setup of a Total Station with Radio (TCPS27) .................................................................... 18

3.5 Setup of a MC75 ............................................................................................................................ 19

3.6 Setup of real-time GNSS with GMX902 Sensors .............................................................................. 20

3.7 Setup of post processing GNSS with GRX1200Pro Sensors.............................................................. 22

3.8 Setup of a Meteo Sensor................................................................................................................ 24

3.9 Setup of a Level ............................................................................................................................. 25

3.10 Remote Setup of a GMX902 Sensor with Radio (GFU-14) .............................................................. 26

3.11 Setup of a GNSS Sensor co-located with a Total Station ............................................................... 28

3.12 Setup of a GMX901 Sensor with standard cables .......................................................................... 30

3.13 Setup of a GMX901 Sensor with custom wired cables ................................................................... 31

3.14 Remote Setup of a GMX901 Sensor with Radio (GFU-14) .............................................................. 32

3.15 Setup of a Nivel210 (RS232) ........................................................................................................ 34

3.16 Setup of a Nivel210 with GRX1200Pro Series................................................................................ 35

3.17 Setup of a Nivel220 (RS485) with Leica cables.............................................................................. 37

3.18 Setup of a Nivel220 (RS485) with long cables ............................................................................... 38

13

GeoMoS is an integrated solution that supports total station, GNSS receivers, levels and geotechnical sensors for an overall understanding of structural movements.

In large monitoring projects total stations and GNSS receivers can be combined in many different ways to match the requirements and use a stable reference. The diagram below shows various possibilities.

Δ

Δ

2

Δ

Legend ▲

Stable reference point

Unstable monitoring point

Δ H, Δ X, Δ Y Offsets to be set in GeoMoS

Total station with co-located GNSS sensor

ƒ A GNSS antenna can be mounted on the top of the measurement hut and applied to the total station stand point with a three-dimensional offset.

ƒ To orientate the system, a GNSS antenna inside the unstable area is used to update the reference point.

ƒ The GNSS antenna needs a reference station so that baselines can be computed.

Reference points with co-located GNSS sensors

ƒ A total station stand point can be measured and calculated with a free station or distance intersection to reference points inside the unstable area.

ƒ A GNSS antenna can be mounted on the top of the prism and applied to the point with a height offset.

ƒ The GNSS antenna needs a reference station so that baselines can be computed.

Reference station

ƒ A GNSS antenna can be mounted in a stable area as a reference station. The reference station should be as close as possible (<3km) to the monitoring area so that the baselines can be computed with the highest accuracy.

14

3.2 Setup of a Total Station with direct serial

734 698

759 257

439 038

749 279

744 793

772 630

664 662

757 129

764 824

Select Total Station

664 662

757 129

764 824

TCA2003, 0.5"(0.15mgon) automatic precision total station, with laser plummet, 2 control panels, accessories, user manual and container.

TM30 0.5”, 0.15gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.

TM30 1”, 0.3gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.

Select Cables and Switchbox

744 793

772 630

734 698

Switchbox with cable 2.0m for TPS/1000/1100/1200 and GeoMoS. Supports cold boot for TPS

(important 24/7 hours/day monitoring).

GDZ 68, Switchbox with a 2.0m cable for TM30/TS30 (Lemo 1) and GeoMoS. Supports cold boot for

TPS (important 24/7 hours/day monitoring).

GEV187, Y-cable, connects TPS/1000/1100/1200 to PC (9-pin RS232 serial) and external battery, 2.0m.

GEV220, Y-cable, connects TM30/TS30 to PC (9-pin RS232 serial) and external battery, 2.0m. 759 257

Select Power

439 038

749 279 cable with 5-pin Lemo to connect to TPS.

Select power cords for 12V power supply unit 749 279. Refer to “

5 Power supply ”.

Select Software

GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.

GEV208, Power supply unit for TPS, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD,

GeoMoS Monitor / Analyzer

Refer to “ 1 GeoMoS Modules

15

3.3 Remote Setup of a Total Station with Radio (GFU14)

639 964

667 243

733 275, 733 276,

738 272, 738 273,

738 274, 738 275,

738 276 733 297

639 964

667 243

733 275, 733 276,

738 272, 738 273,

738 274, 738 275,

738 276

733 297

439 038

749 279 439 038

Mini Adapter

734 698

759 257

664 662

757 129

764 824

439 038

749 279

749 279

744 793

772 630

Select Total Station

664 662

757 129

764 824

TCA2003, 0.5"(0.15mgon) automatic precision total station, with laser plummet, 2 control panels, accessories, user manual and container.

TM30 0.5”, 0.15gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.

TM30 1”, 0.3gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.

Select Cables and Switchbox

744 793

772 630

734 698

759 257

733 297

Mini adapter

Switchbox with cable 2.0m for TPS/1000/1100/1200 and GeoMoS. Supports cold boot for TPS

(important 24/7 hours/day monitoring)

GDZ 68, Switchbox with a 2.0m cable for TM30/TS30 (Lemo 1) and GeoMoS. Supports cold boot for

TPS (important 24/7 hours/day monitoring).

GEV187, Y-cable, connects TPS/1000/1100/1200 to PC (9-pin RS232 serial) and external battery, 2.0m.

GEV220, Y-cable, connects TM30/TS30 to PC (9-pin RS232 serial) and external battery, 2.0m.

GEV171, 1.8m cable to program, the Satelline 3AS radio modem inside the GFU14 housing.

Null modem, DB9 male to DB9 male. Refer to “

9.7.2 Mini adapter

”.

Select Radio Modem

733 275

733 276

738 272

738 273

738 274

738 275

738 276

GFU14-0, Satelline 3AS radio modem (433.525 MHz, 25.0 kHz channel spacing, 0.5 W)

GFU14-1, Satelline 3AS radio modem (406.425 MHz, 25.0 kHz channel spacing, 1.0 W)

GFU14-2, Satelline 3AS radio modem (445.000 MHz, 12.5 kHz channel spacing, 1.0 W)

GFU14-3, Satelline 3AS radio modem (443.000 MHz, 12.5 kHz channel spacing, 1.0 W)

GFU14-4, Satelline 3AS radio modem (440.550 MHz, 25.0 kHz channel spacing, 0.5 W)

GFU14-5, Satelline 3AS radio modem (458.150 MHz, 12.5 kHz channel spacing, 0.5 W)

GFU14-6, Satelline 3AS radio modem (439.8625 MHz, 12.5 kHz channel spacing, 1.0 W)

16

Select Radio Antenna

639 964 GAT1, Gainflex radio antenna, frequency range 400-435MHz.

GAT2, Gainflex radio antenna, frequency range 435-470MHz. 667 243

Select Power

439 038

749 279

GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.

GEV208, Power supply unit for TPS, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to TPS.

Select power cords for 12V power supply unit 749 279. Refer to “

5 Power supply ”.

Select Software

GeoMoS Monitor / Analyzer

Refer to “ 1 GeoMoS Modules

17

3.4 Remote Setup of a Total Station with Radio (TCPS27)

734161

734162

734 699

734 697

771 057 664 662

757 129

764 824

439 038

439 038

749 279

749 279

744 793

772 630

Select Total Station

664 662

757 129

764 824

TCA2003, 0.5"(0.15mgon) automatic precision total station, with laser plummet, 2 control panels, accessories, user manual and container.

TM30 0.5”, 0.15gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.

TM30 1”, 0.3gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.

Select cables and switchbox

744 793

772 630

734 697

771 057

Switchbox with cable 2.0m for TPS/1000/1100/1200 and GeoMoS. Supports cold boot for TPS

(important 24/7 hours/day monitoring)

GDZ 68, Switchbox with a 2.0m cable for TM30/TS30 (Lemo 1) and GeoMoS. Supports cold boot for

TPS (important 24/7 hours/day monitoring).

GEV186, Y-cable, connects TCPS27 to TPS/1000/1100/1200 and external battery, 1.8m.

GEV236, Y-cable, connects TM30/TS30 to TCPS radio and external battery, 2m.

734 699

Select Radio Modem

GEV188, Y-cable, connects TCPS27 to PC (9-pin RS232 serial) and external battery, 1.8m.

734 161

734 162

TCPS27 B, radio modem (base), with antenna, user manual. Used as radio modem for TPS1200

(frequency range 2400 - 2483 Mhz).

TCPS27 R, radio modem (remote), with antenna, user manual. Used as external radio for PC (frequency range 2400 - 2483 MHz).

Select Power

439 038

749 279

GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.

GEV208, Power supply unit for TPS, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to TPS.

Select power cords for 12V power supply unit 749 279. Refer to “

5 Power supply ”.

Select Software

GeoMoS Monitor / Analyzer

Refer to “ 1 GeoMoS Modules

Important:

ƒ Use the TCPS27 ConfigTool from the CD to set the correct baud rate and link number.

ƒ Enable the RTS mode in the GeoMoS Monitor software.

18

3.5 Setup of a MC75

667 237

750 242

733 297

439 038

SIM card

749 279

750 242

667 237

733 297

GFU24, Housing with Siemens MC75 GSM/GPRS Module (Quad-Band GSM 850/900/1800/1900 MHz).

Antenna for 900/1800 MHz mobile network.

GEV171, 1.8m cable to program, the Satelline 3AS radio modem inside the GFU14 housing. Also used to connect GFU24 to PC.

Select Power

439 038

749 279

GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.

GEV208, Power supply unit for TPS, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to TPS.

Select power cords for 12V power supply unit 749 279. Refer to “

5 Power supply ”.

Select Software

GeoMoS Monitor / Analyzer

Refer to “ 1 GeoMoS Modules

19

3.6 Setup of real-time GNSS with GMX902 Sensors

747 958

766 714

722 409

632 372 (10m)

632 390 (30m)

758 600

667 140

765 734

755 267

765 733

563 809 733 280

Modem

632 372

632 390

Select Power

Select Receiver

758 600 GMX902 GG, GNSS Dual Frequency Receiver for Monitoring Applications.

Select Antenna

747 958

766 714

755 267

765 733

AX1203+ GNSS, GPS/GLONASS/Galileo Triple Frequency Antenna for all GRX1200 Series and GRX1200+

Series receivers.

AX1202 GG, Dual Frequency Antenna for GX1230 GG and GRX 1200 GG Pro Receiver

AT504 GG, GPS/GLONASS dual-frequency choke-ring antenna for GPS/GLONASS receivers. Dorne-

Margolin antenna element, JPL design. Conforms to IGS "Typ T" specification for GPS antennas. For

GX1220 / 1230, GRX1200 and GMX902 Receivers.

AR25, GNSS choke ring antenna for GPS/GLONASS/Galileo/Compass receivers. Includes L-Band signals.

Dorne-Margolin antenna element.

GVP601, Weather-protection radome for AT504 choke ring antenna. 667 140

765 734 GVP653, Weather-protection radome AR25 choke ring antenna.

Select Antenna Cables

Antenna cable, 10 m

Antenna cable, 30 m

722 409 Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.

Select power cords for 12V power supply unit 722 409. Refer to “

5 Power supply ”.

20

Select Communication between Sensors and Spider

733 280

563 809

GEV160, 2.8m Data transfer cable. Connects GPS1200 receiver Ports 1, 2 and 3, RX1220 or GMX902 to

PC for data transfer, firmware upload etc. Lemo 8 Pin to 9 pin RS232 female serial connector.

GEV113, 2.8m Modem cable. Connects GPS receiver Ports 1, 2 and 3 to modem. Lemo 8 Pin to 9 Pin

RS232 male serial connector.

Select Software

Leica GNSS Spider

Optional Software

GeoMoS Monitor / Analyzer

Leica GNSS QC

Refer to “

Refer to “

Refer to “

4.2.4 GNSS Spider ”

1 GeoMoS Modules

4.2.5 GNSS QC

Note: If you connect more than one GNSS receiver to GeoMoS to use for monitoring we recommend GNSS connection to the Leica Spider software. GeoMoS supports an interface to Leica GNSS Spider software (order GNSS Spider and accessories separately)

21

3.7 Setup of post processing GNSS with GRX1200Pro Sensors

747 958

766 714

667 140

765 734

755 267

765 733

632 372 (10m )

)

766 730

766 733

722 409

733 257

745 995

733 290 563 809

LAN / WAN

733 280

Modem

Select Receiver

766 730

766 733

GRX1200+, Triple Frequency GPS Reference Station Receiver, Professional, with Event Input, PPS

Output, External Oscillator Input and Ethernet connectivity. Includes L2C.

GRX1200+, GPS/GLONASS/Galileo Triple Frequency Reference Station Receiver, Professional, with Event

Input, PPS Output, External Oscillator Input and Ethernet connectivity. Includes L2C. Requires separate

Purchasable Options software options for full time GPS L5/GLONASS and Galileo.

For additional information see

745 972 Equipment list “For GNSS Networks and Reference Stations”

Select CompactFlash Card

733 257 MCF256, CompactFlash card 256MB.

MCF1000, CompactFlash card 1GB. 745 995

Select Antenna

747 958

766 714

755 267

AX1203+ GNSS, GPS/GLONASS/Galileo Triple Frequency Antenna for all GRX1200 Series and GRX1200+

Series receivers.

AX1202 GG, Dual Frequency Antenna for GX1230 GG and GRX 1200 GG Pro Receiver

AT504 GG, GPS/GLONASS dual-frequency choke-ring antenna for GPS/GLONASS receivers. Dorne-

Margolin antenna element, JPL design. Conforms to IGS "Typ T" specification for GPS antennas. For

GX1220 / 1230, GRX1200 and GMX902 Receivers.

22

765 733

667 140

765 734

Select Antenna Cables

AR25, GNSS choke ring antenna for GPS/GLONASS/Galileo/Compass receivers. Includes L-Band signals.

Dorne-Margolin antenna element.

GVP601, Weather-protection radome for AT504 choke ring antenna.

GVP653, Weather-protection radome AR25 choke ring antenna.

632 372

632 390

Select Power

Antenna cable, 10 m

Antenna cable, 30 m

722 409 Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.

Select power cords for 12V power supply unit 722 409. Refer to “

5 Power supply ”.

Select Communication between Sensors and Spider

733 280

563 809

GEV160, 2.8m Data transfer cable. Connects GPS1200 receiver Ports 1, 2 and 3, RX1220 or GMX902 to

PC for data transfer, firmware upload etc. Lemo 8 Pin to 9 pin RS232 female serial connector.

GEV113, 2.8m Modem cable. Connects GPS receiver Ports 1, 2 and 3 to modem. Lemo 8 Pin to 9 Pin

RS232 male serial connector.

GEV168, 5.0m cable, connecting GPS Receiver with Ethernet LAN / RJ45 733 290

Select Software

Leica GNSS Spider

Optional Software

GeoMoS Monitor / Analyzer

Leica GNSS QC

Refer to “

Refer to “

Refer to “

4.2.4 GNSS Spider ”

1 GeoMoS Modules

4.2.5 GNSS QC

Note: If you connect more than one GNSS receiver to GeoMoS to use for monitoring we recommend GNSS connection to the Leica Spider software. GeoMoS supports an interface to Leica GNSS Spider software (order GNSS Spider and accessories separately)

23

3.8 Setup of a Meteo Sensor

734 698

667 726

749 279

439 038

Select Sensor

667 726 DTM meteo sensor, combined pressure and temperature sensor 2m cable with Lemo1 plug. (other lengths of cable on request).

Select Sensor

734 698

764 328

GEV187, Y-cable, connects TPS to PC (9-pin RS232 serial) and external battery, 2.0m.

GEV222, Adapter cable DTM sensor, Lemo-1 (female) to Lemo-0 (female), 3.0m

Select Power

439 038

749 279

GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.

GEV208, Power supply unit for TPS, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to TPS.

Select power cords for 12V power supply unit 749 279. Refer to “

5 Power supply ”.

Select Software

GeoMoS Monitor / Analyzer

Refer to “ 1 GeoMoS Modules

Important:

ƒ Remove the yellow transportation cover for monitoring

ƒ The DTM meteo sensor should be mounted upside down

24

3.9 Setup of a Level

734 698

723 289

726 540

744 793

749 279

439 038

738 933

741 868

Select Level

723 289

726 540

738 933

734 698

Select Power

DNA03, 0.3mm, precision digital level, magnetically-damped compensator, with user manual and container.

DNA10, 0.9mm, digital level, magnetically-damped compensator, with user manual and container.

SPRINTER 100M, 2.0mm, electronic level, with RS232 interface & internal memory, with user manual, 4 pcs AA dry cells and container.

SPRINTER 200M, 1.5mm, electronic level, with RS232 interface & internal memory, with user manual, 4 741 868 pcs AA dry cells and container.

Select Cables and Switchbox

744 793 Switchbox with cable 2.0m for TPS/1000/1100/1200 and GeoMoS. Supports cold boot for TPS

(important 24/7 hours/day monitoring)

GEV187, Y-cable, connects TPS to PC (9-pin RS232 serial) and external battery, 2.0m.

439 038

749 279

GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.

GEV208, Power supply unit for TPS, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to TPS.

Select power cords for 12V power supply unit 749 279. Refer to “

5 Power supply ”.

Select Staff

Refer to “ 4.3.2 DNA Staffs ” and “ 4.3.3 Sprinter Staffs ”.

Select Software

GeoMoS Monitor / Analyzer

Refer to “ 1 GeoMoS Modules

25

3.10 Remote Setup of a GMX902 Sensor with Radio (GFU-14)

747 958

766 714

667 140

765 734

755 267

765 733

639 964

667 243

733 275, 733 276,

738 272, 738 273,

738 274, 738 275,

738 276

632 372 (10m)

632 390 (30m)

639 964

667 243

733 275, 733 276,

738 272, 738 273,

738 274, 738 275,

738 276

722 409

758 600

733 297

563 809

439 038

733 297

439 038

749 279

749 279

Select Receiver

758 600

Select Antenna

747 958

GMX902 GG, GNSS Dual Frequency Receiver for Monitoring Applications.

766 714

755 267

765 733

667 140

765 734

AX1203+ GNSS, GPS/GLONASS/Galileo Triple Frequency Antenna for all GRX1200 Series and GRX1200+

Series receivers.

AX1202 GG, Dual Frequency Antenna for GX1230 GG and GRX 1200 GG Pro Receiver

AT504 GG, GPS/GLONASS dual-frequency choke-ring antenna for GPS/GLONASS receivers. Dorne-

Margolin antenna element, JPL design. Conforms to IGS "Typ T" specification for GPS antennas. For

GX1220 / 1230, GRX1200 and GMX902 Receivers.

AR25, GNSS choke ring antenna for GPS/GLONASS/Galileo/Compass receivers. Includes L-Band signals.

Dorne-Margolin antenna element.

GVP601, Weather-protection radome for AT504 choke ring antenna.

GVP653, Weather-protection radome AR25 choke ring antenna.

Select Antenna Cables

632 372

632 390

Antenna cable, 10 m

Antenna cable, 30 m

Select Radio Modem

733 275 GFU14-0, Satelline 3AS radio modem (433.525 MHz, 25.0 kHz channel spacing, 0.5 W)

733 276

738 272

738 273

738 274

738 275

738 276

GFU14-1, Satelline 3AS radio modem (406.425 MHz, 25.0 kHz channel spacing, 1.0 W)

GFU14-2, Satelline 3AS radio modem (445.000 MHz, 12.5 kHz channel spacing, 1.0 W)

GFU14-3, Satelline 3AS radio modem (443.000 MHz, 12.5 kHz channel spacing, 1.0 W)

GFU14-4, Satelline 3AS radio modem (440.550 MHz, 25.0 kHz channel spacing, 0.5 W)

GFU14-5, Satelline 3AS radio modem (458.150 MHz, 12.5 kHz channel spacing, 0.5 W)

GFU14-6, Satelline 3AS radio modem (439.8625 MHz, 12.5 kHz channel spacing, 1.0 W)

26

Select Radio Antenna

639 964 GAT1, Gainflex radio antenna, frequency range 400-435MHz.

GAT2, Gainflex radio antenna, frequency range 435-470MHz. 667 243

Select Power

439 038

749 279

GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.

GEV208, Power supply unit for TPS, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to TPS.

Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, 722 409 cable with 5-pin Lemo to connect to GPS.

Select power cords for 12V power supply unit 722 409 and 749 279. Refer to “ 5 Power supply

”.

Select Communication Cables

563 809 GEV113, 2.8m Modem cable. Connects GPS receiver Ports 1, 2 and 3 to modem. Lemo 8 Pin to 9 Pin

733 297

Select Software

Leica GNSS Spider

Optional Software

RS232 male serial connector.

GEV171, 1.8m cable to program, the Satelline 3AS radio modem inside the GFU14 housing

GeoMoS Monitor / Analyzer

Leica GNSS QC

Refer to “

Refer to “

Refer to “

4.2.4 GNSS Spider ”

1 GeoMoS Modules

4.2.5 GNSS QC

Note: If you connect more than one GNSS receiver to GeoMoS to use for monitoring we recommend GNSS connection to the Leica Spider software. GeoMoS supports an interface to Leica GNSS Spider software (order GNSS Spider and accessories separately)

27

3.11 Setup of a GNSS Sensor co-located with a Total Station

747 958

766 714

667 140

765 734

755 267

765 733

632 372 (10m)

632 390 (30m)

722 409

758 600

664 662

757 129

764 824

733 280

734 698

759 257

744 793

772 630

439 038

749 279

Select Total Station

664 662

757 129

764 824

TCA2003, 0.5"(0.15mgon) automatic precision total station, with laser plummet, 2 control panels, accessories, user manual and container.

TM30 0.5”, 0.15gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.

TM30 1”, 0.3gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.

Select Cables and Switchbox

744 793

772 630

734 698

Switchbox with cable 2.0m for TPS/1000/1100/1200 and GeoMoS. Supports cold boot for TPS

(important 24/7 hours/day monitoring)

GDZ 68, Switchbox with a 2.0m cable for TM30/TS30 (Lemo 1) and GeoMoS. Supports cold boot for

TPS (important 24/7 hours/day monitoring).

GEV187, Y-cable, connects TPS/1000/1100/1200 to PC (9-pin RS232 serial) and external battery, 2.0m.

GEV220, Y-cable, connects TM30/TS30 to PC (9-pin RS232 serial) and external battery, 2.0m. 759 257

Select Receiver

758 600

733 280

GMX902 GG, GNSS Dual Frequency Receiver for Monitoring Applications.

Communication Cable

GEV160, 2.8m Data transfer cable. Connects GPS1200 receiver Ports 1, 2 and 3, RX1220 or GMX902 to

PC for data transfer, firmware upload etc. Lemo 8 Pin to 9 pin RS232 female serial connector.

28

Select Antenna

747 958

766 714

755 267

765 733

667 140

765 734

AX1203+ GNSS, GPS/GLONASS/Galileo Triple Frequency Antenna for all GRX1200 Series and GRX1200+

Series receivers.

AX1202 GG, Dual Frequency Antenna for GX1230 GG and GRX 1200 GG Pro Receiver

AT504 GG, GPS/GLONASS dual-frequency choke-ring antenna for GPS/GLONASS receivers. Dorne-

Margolin antenna element, JPL design. Conforms to IGS "Typ T" specification for GPS antennas. For

GX1220 / 1230, GRX1200 and GMX902 Receivers.

AR25, GNSS choke ring antenna for GPS/GLONASS/Galileo/Compass receivers. Includes L-Band signals.

Dorne-Margolin antenna element.

GVP601, Weather-protection radome for AT504 choke ring antenna.

GVP653, Weather-protection radome AR25 choke ring antenna.

Select Antenna Cables

632 372 Antenna cable, 10 m

632 390 Antenna cable, 30 m

Select Power

439 038

749 279

GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.

GEV208, Power supply unit for TPS, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD,

722 409 cable with 5-pin Lemo to connect to TPS.

Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.

Select power cords for 12V power supply unit 722 409 and 749 279. Refer to “ 5 Power supply

”.

Select Software

GeoMoS Monitor / Analyzer

Leica GNSS Spider

Leica GNSS QC

Refer to “ 1 GeoMoS Modules

Refer to “ 4.2.4 GNSS Spider ”

Refer to “ 4.2.5 GNSS QC

Note: If you connect more than one GNSS receiver to GeoMoS to use for monitoring we recommend GNSS connection to the Leica Spider software. GeoMoS supports an interface to Leica GNSS Spider software (order GNSS Spider and accessories separately)

29

3.12 Setup of a GMX901 Sensor with standard cables

439 038 560 130

636 972

743 389

722 409

755 231

Select Receiver

755 231

Select Power

GMX901, GPS Smart Antenna for Monitoring Applications

439 038

722 409

GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.

Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.

Select power cords for 12V power supply unit 722 409. Refer to “

5 Power supply ”.

To connect battery, car battery or alternate power supply

560 130 1.8m cable, connects GEB171 external battery to GPS1200 receiver. Lemo-1, 5 pin, male to Lemo-1, 5

636 972 pin, male.

0.5m cable, connects GEB171 external battery to GPS1200 receiver. Lemo-1, 5 pin, male to Lemo-1, 5 pin, male.

Select Communication between Sensors and Spider

743 389

Select Software

GEV197, Y-Cable, 2.8m, GMX901 to RS232 and external Leica power supply.

Leica GNSS Spider

Optional Software

GeoMoS Monitor / Analyzer

Leica GNSS QC

Refer to “

Refer to “

Refer to “

4.2.4 GNSS Spider ”

1 GeoMoS Modules

4.2.5 GNSS QC

Note: If you connect more than one GNSS receiver to GeoMoS to use for monitoring we recommend GNSS connection to the Leica Spider software. GeoMoS supports an interface to Leica GNSS Spider software (order GNSS Spider and accessories separately)

30

3.13 Setup of a GMX901 Sensor with custom wired cables

755 231

750 073

3

4 blue green

5 black

7 red

GND

Data In

Data In

Data Out

GND

Data Out

PWR In

GND

PWR In

Select Receiver

755 231 GMX901, GPS Smart Antenna for Monitoring Applications

Power / Communication

750 073

Select Software

GEV212, Interface Cable, 5m, GMX901 to unterminated, connects GMX901 to a custom installation.

Leica GNSS Spider

Optional Software

GeoMoS Monitor / Analyzer

Leica GNSS QC

Refer to “

Refer to “

Refer to “

4.2.4 GNSS Spider ”

1 GeoMoS Modules

4.2.5 GNSS QC

Note: If you connect more than one GNSS receiver to GeoMoS to use for monitoring we recommend GNSS connection to the Leica Spider software. GeoMoS supports an interface to Leica GNSS Spider software (order GNSS Spider and accessories separately)

31

3.14 Remote Setup of a GMX901 Sensor with Radio (GFU-14)

439 038 560 130

636 972 755 231

743 389

Solar panel / Battery

Mini Adapter

439 038

733 297

639 964

667 243

733 275, 733 276,

738 272, 738 273,

738 274, 738 275,

738 276

439 038

749 279

733 297

639 964

667 243

733 275, 733 276,

738 272, 738 273,

738 274, 738 275,

738 276

Select Receiver

755 231

Select Accessories

GMX901, GPS Smart Antenna for Monitoring Applications

Mini adapter

Null modem, DB9 male to DB9 male. Refer to “

9.7.2 Mini adapter

”.

Select Radio Modem

733 275 GFU14-0, Satelline 3AS radio modem (433.525 MHz, 25.0 kHz channel spacing, 0.5 W)

733 276

738 272

738 273

738 274

GFU14-1, Satelline 3AS radio modem (406.425 MHz, 25.0 kHz channel spacing, 1.0 W)

GFU14-2, Satelline 3AS radio modem (445.000 MHz, 12.5 kHz channel spacing, 1.0 W)

GFU14-3, Satelline 3AS radio modem (443.000 MHz, 12.5 kHz channel spacing, 1.0 W)

GFU14-4, Satelline 3AS radio modem (440.550 MHz, 25.0 kHz channel spacing, 0.5 W)

32

738 275

738 276

GFU14-5, Satelline 3AS radio modem (458.150 MHz, 12.5 kHz channel spacing, 0.5 W)

GFU14-6, Satelline 3AS radio modem (439.8625 MHz, 12.5 kHz channel spacing, 1.0 W)

Select Radio Antenna

639 964 GAT1, Gainflex radio antenna, frequency range 400-435MHz.

GAT2, Gainflex radio antenna, frequency range 435-470MHz. 667 243

Select Power

439 038

749 279

GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.

GEV208, Power supply unit for TPS, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to TPS.

Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, 722 409 cable with 5-pin Lemo to connect to GPS.

Select power cords for 12V power supply unit 722 409 and 749 279. Refer to “ 5 Power supply

”.

To connect battery, car battery or alternate power supply

560 130 1.8m cable, connects GEB171 external battery to GPS1200 receiver. Lemo-1, 5 pin, male to Lemo-1, 5

636 972 pin, male.

0.5m cable, connects GEB171 external battery to GPS1200 receiver. Lemo-1, 5 pin, male to Lemo-1, 5 pin, male.

Select Communication Cables

733 297

743 389

Select Software

GEV171, 1.8m cable to program, the Satelline 3AS radio modem inside the GFU14 housing

GEV197, Y-Cable, 2.8m, GMX901 to RS232 and external Leica power supply.

Leica GNSS Spider

Optional Software

GeoMoS Monitor / Analyzer

Leica GNSS QC

Refer to “

Refer to “

Refer to “

4.2.4 GNSS Spider ”

1 GeoMoS Modules

4.2.5 GNSS QC

Note: If you connect more than one GNSS receiver to GeoMoS to use for monitoring we recommend GNSS connection to the Leica Spider software. GeoMoS supports an interface to Leica GNSS Spider software (order GNSS Spider and accessories separately)

33

3.15 Setup of a Nivel210 (RS232)

576 198

802 902

PC

748 335

722 409

Select Sensor

576 198 NIVEL210, inclination sensor with RS232 interface

Select Cables and Accessories

748 335

802 902

749 031

Select Power

GEV204, Power supply-cab.f. NIVEL210/230

Cable, PC- NIVEL210, (Lemo-RS232), 1m

GHT59, Wall Mounting Kit for NIVEL200

722 409 Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.

Select power cords for 12V power supply unit 722 409. Refer to “

5 Power supply ”.

Select Software

Important

GeoMoS Monitor / Analyzer

GNSS QC

ƒ

Refer to “

Refer to “

1 GeoMoS Modules

4.2.5 GNSS QC

Use the NivelTool software from the CD to set the correct Nivel ID and baud rate.

34

3.16 Setup of a Nivel210 with GRX1200Pro Series

747 958

766 714

667 140

765 734

755 267

765 733

722 409

766 730

766 733

749 916

733 257

745 995

576 198

733 280

Select Sensor

576 198 NIVEL210, inclination sensor with RS232 interface

Select Cables and Accessories

749 916 GEV209, Cable, NIVEL210 - GPS1200, 1.8m

733 280 GEV160, 2.8m Data transfer cable. Connects GPS1200 receiver Ports 1, 2 and 3, RX1220 or GMX902 to

PC for data transfer, firmware upload etc. Lemo 8 to 9 pin RS232 female serial connector.

GHT59, Wall Mounting Kit for NIVEL200 749 031

Select Receiver

766 730

766 733

GRX1200+, Triple Frequency GPS Reference Station Receiver, Professional, with Event Input, PPS

Output, External Oscillator Input and Ethernet connectivity. Includes L2C.

GRX1200+, GPS/GLONASS/Galileo Triple Frequency Reference Station Receiver, Professional, with Event

Input, PPS Output, External Oscillator Input and Ethernet connectivity. Includes L2C. Requires separate software options for full time GPS L5/GLONASS and Galileo.

Purchasable Options

For additional information see

745 972 Equipment list “For GNSS Networks and Reference Stations”

Select CompactFlash Card

733 257

745 995

MCF256, CompactFlash card 256MB.

MCF1000, CompactFlash card 1GB.

Select Antenna

747 958

766 714

AX1203+ GNSS, GPS/GLONASS/Galileo Triple Frequency Antenna for all GRX1200 Series and GRX1200+

Series receivers.

AX1202 GG, Dual Frequency Antenna for GX1230 GG and GRX 1200 GG Pro Receiver

35

755 267

765 733

AT504 GG, GPS/GLONASS dual-frequency choke-ring antenna for GPS/GLONASS receivers. Dorne-

Margolin antenna element, JPL design. Conforms to IGS "Typ T" specification for GPS antennas. For

GX1220 / 1230, GRX1200 and GMX902 Receivers.

AR25, GNSS choke ring antenna for GPS/GLONASS/Galileo/Compass receivers. Includes L-Band signals.

Dorne-Margolin antenna element.

GVP601, Weather-protection radome for AT504 choke ring antenna. 667 140

765 734 GVP653, Weather-protection radome AR25 choke ring antenna.

Select Antenna Cables

632 372

632 390

Select Power

Antenna cable, 10 m

Antenna cable, 30 m

722 409 Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.

Select power cords for 12V power supply unit 722 409. Refer to “

5 Power supply ”.

Select Software

GRX onboard software

Important ƒ Use the NivelTool software from the CD to set the correct Nivel ID and baud rate.

36

3.17 Setup of a Nivel220 (RS485) with Leica cables

Cables supplied by Leica Geosystems

567 199

567 199

567 199

575 869

RS232 cable

Converter

802 906 or

802 907

722 409

748 488 802 906 or

802 907

Select Sensor

576 199 NIVEL220, inclination sensor with R4852 interface

Select Cables and Accessories

748 488

748 489

0.8m power supply cable, connects power supply unit 722 409 to RS232/RS485 converter, Lemo-0 to

2 wires to terminal strip.

1.8m communication cable, connects Nivel220 to RS232/RS485 converter, Lemo-0 to 4 wires to terminal strip.

5.0m connection cable RS485. Connects two Nivel220 sensor ports 1 or 2, Lemo-0 to Lemo-0. 802 906

802 907

575 869

RS232 cable

20.0m connection cable RS485. Connects two Nivel220 sensor ports 1 or 2, Lemo-0 to Lemo-0.

Terminator 120 Ohm, for RS485 Bus

DB9 cable, DB9 male to DB9 female. Refer to “ 9.7.1 Cables ”.

Converter RS232/RS485 converter. Refer to “

9.1 RS232/RS485 converter ”.

749 031

Select Power

GHT59, Wall Mounting Kit for NIVEL200

722 409 Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.

Select power cords for 12V power supply unit 722 409. Refer to “

5 Power supply ”.

Select Software

GeoMoS Monitor / Analyzer

GNSS QC

Refer to “

Refer to “

1 GeoMoS Modules

4.2.5 GNSS QC

Important ƒ Use the NivelTool software from the CD to set the correct Nivel ID and baud rate.

37

3.18 Setup of a Nivel220 (RS485) with long cables

Cables supplied by Leica Geosystems and CAT cables

General information

ƒ For the installation of the cables of the Nivel220 sensors, the general rules for the installation of electrical wiring apply.

ƒ Avoid sharp bends and lay the cable in large loops within the range of rotating or moving parts.

ƒ When installing the cables, please observe the already existing installation of electric system.

ƒ After having completed the installation, please drive through all possible positions in order to make sure that the cables are not touching, stretched or even squeezed by any moving parts.

Please consider that a well-planned and thoroughly carried out electric installation does not only protect the cables against damages, but also looks professional.

Sensor auxiliary supply

Power for the Nivel220 sensor must be supplied externally. The power is connected to the sensor using a LEMO cable.

The auxiliary supply voltage at the Nivel220 sensor must be within the permissible range. Refer to "Nivel 200 User Manual". The correct operation of the sensor cannot be guaranteed when the supply voltage is not within this range and it can be damaged by overvoltages. For the voltage drop along long supply cables take into account and, if necessary, correspondingly increase the voltage at the supply end. The voltage drop is given by the following equation: voltage drop [V] = resistance per m [/m] * 2 * cable length [m] * current [A]

It can be assumed that the voltage drop is varying should the current through the sensor appear to fluctuate. A Nivel220 requires typically 50mA. Refer to "Nivel 200 User Manual".

Use the Leica Geosystems power supply recommended by Leica Geosystems to ensure the correct functionality of the Nivel220 sensor.

Voltage drop computation

225 m 45 m 45 m

Power supply

150 mA 100 mA 50 mA

220V

N1 N2 N3

12.00 V voltage drop [V] = 0.1 [Ω/m] * 2 * 225 [m] * 0.15 [A] = 6.75 [V] voltage drop [V] = 0.1 [Ω/m] * 2 * 45 [m] * 0.10 [A] = 0.90 [V] voltage drop [V] = 0.1 [Ω/m] * 2 * 45 [m] * 0.05 [A] = 0.45 [V]

total amount voltage drop = 8.10 [V]

5.25 V 4.35 V 3.90 V

38

With one power source

RS232 cable

722 409

748 488

Converter

567 199

748 489

567 199

575 869

748 489

748 489

Terminal strip

Terminal strip

Terminal strip

CAT6 cable

748 489

CAT6 cable

Select Sensor

576 199 NIVEL220, inclination sensor with R4852 interface

Select Cables and Accessories

748 488 0.8m power supply cable, connects power supply unit 722 409 to RS232/RS485 converter,

Lemo-0 to 2 wires to terminal strip.

1.8m communication cable, connects Nivel220 to RS232/RS485 converter, Lemo-0 to 4 wires

575 869

RS232 cable

Converter

Terminal strip

CAT6 cable

749 031

Select Power to terminal strip.

Terminator 120 Ohm, for RS485 Bus

DB9 cable, DB9 male to DB9 female. Refer to “

9.7.1 Cables

”.

RS232/RS485 converter. Refer to “ 9.1 RS232/RS485 converter

”.

GHT59, Wall Mounting Kit for NIVEL200

722 409 Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.

Select power cords for 12V power supply unit 722 409. Refer to “

5 Power supply ”.

Select Software

Important

GeoMoS Monitor / Analyzer

GNSS QC

ƒ

Refer to “

Refer to “

1 GeoMoS Modules

4.2.5 GNSS QC

Use the NivelTool software from the CD to set the correct Nivel ID and baud rate.

39

With multiple power sources

RS232 cable

722 409

748 488

Converter

567 199

748 489

567 199

Terminal strip

CAT6 cable

748 488

748 489

748 489

Terminal strip

Terminal strip

CAT6 cable

748 488

722 409

722 409

Equipment list see above “With one power source”

575 869

40

Sensors

4.1 TPS Sensors

4.1.1 Supported Sensors

Leica TPS 1000 Series

Leica TPS 1100 Series

Leica TPS 1200 Series

Note: Only automated TPS can be used with GeoMoS. Instruments with ATR are recommended.

TM30, TCA2003 and TCA1800 instruments are recommended.

664 662

667 016

TCA2003, 0.5"(0.15mgon) automatic precision total station, with laser plummet, 2 control panels, accessories, user manual and container.

TCA1800, 1"(0.3mgon) automatic total station with laser plummet, 2 control panels, accessories, user manual and container. recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container. recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container. recognition, Power Search, communication sidecover, internal memory, laser plummet, 2 keyboard, electronic guide light EGL, standard applications, user manuals, and upright container.

TCA1201M instruments are recommended for long-range monitoring (>1000m)

748 872 TCA1201M, total station with long-range EDM for monitoring, automatic target recognition, laser plummet, 1 keyboard with touch screen, electronic guide light EGL, standard applications, user manual, and container.

Customer Care Packages

A wide selection of comprehensive Customer Care Packages is available bundling Hardware

Maintenance, Software Maintenance, Customer Support and Extended Warranty. For more information about the CCP offering in your country please contact your local Leica Geosystems organization or distribution partner.

41

4.1.2 Supported Reflectors

The number of prisms needed is dependent on the project.

Circular reflector

641 617 Circular prism GPR121 PRO, with holder and target plate

Monitoring prisms

726 295

726 296

727 406

GPR112 Monitoring-Mining Prism, with M8 internal thread in the back for direct mounting and 5/8" adapter.

GHT112 Mounting set for GPR112 with M8 and 5/8" internal thread adapters, suitable for direct fixing systems on nearly every surface, prism is adjustable and fixable in two axes.

GDZ112, rain shelter for Monitoring Mining Prism GPR112. Full availability of the prism even in rainy conditions. The rain shelter protects the prism front against rain drops and dust which is washed out from of the air by rain.

Precision reflector

555 631

Mini prism for short distances

641 662

Single-prism precision reflector GPH1P.

641 762

Mini prism GMP101, incl. bubble, target plate and spike, in bag, also suitable for GLS11 and GRT44 (same height as GPH1, additive constant +17.5mm)

Mini prism GMP104, with L-bar, for fixed installations.

360° Reflectors

639 985

754 384

GRZ4 360° Reflector.

Reflector with 5/8" thread adapter for mounting of GPS antenna.

4.1.3 Tribrachs

443 603

667 304

4.1.4 Other TPS Accessories

Tribrach GDF21 for TPS1000 Series, without optical plummet, light green.

Tribrach GDF121 PRO for TPS1200 Series, without optical plummet, pale green.

For additional information see:

740 623

738 605

761 756

Leica System 2000 Brochure.

Leica TPS1200 Series Equipment List

Leica Original Accessories Program

42

4.2 GNSS Sensors

4.2.1 Supported Sensors

Leica GPS System 500

Leica GPS System 1200

Leica GMX900 Series

For detailed description and article numbers see Equipment lists for System 500/1200 and Equipment list for GNSS Networks and Reference Stations.

Note: The particular of model of that GNSS that is recommended depends on how the sensor connection is made to GeoMoS. If the GNSS is to be directly connected to GeoMoS (computation done on the sensor), RTK rover GNSS must be used. If the position computation is to be done by Leica GNSS Spider (recommended) then reference station GNSS or monitoring receivers should be used.

GNSS Sensors for Direct Connection to GeoMoS (RTK)

766 710

766 711

GX1220+, Geodetic GPS Dual Frequency Receiver. Sensor can be upgraded to GNSS receiver

GX1230+, Geodetic GPS Dual Frequency RTK Receiver. Sensor can be upgraded to GNSS receiver

GNSS Sensors for Connection via GNSS Spider

766 730

766 733

Monitoring receiver

755 231

758 600

GRX1200+, Triple Frequency GPS Reference Station Receiver, Professional, with Event

Input, PPS Output, External Oscillator Input and Ethernet connectivity. Includes L2C.

GRX1200+, GPS/GLONASS/Galileo Triple Frequency Reference Station Receiver,

Professional, with Event Input, PPS Output, External Oscillator Input and Ethernet connectivity. Includes L2C. Requires separate software options for full time GPS

L5/GLONASS and Galileo.

GMX901, GPS Smart Antenna for Monitoring Applications

GMX902 GG, GNSS Dual Frequency Receiver for Monitoring Applications.

Purchasable Options

For additional information see

745 972 Equipment list “For GNSS Networks and Reference Stations”

Customer Care Packages

A wide selection of comprehensive Customer Care Packages is available bundling Hardware

Maintenance, Software Maintenance, Customer Support and Extended Warranty. For more information about the CCP offering in your country please contact your local Leica Geosystems organization or distribution partner.

Extended Warranty

89 332

5301720

5301721

5301722

5301723

5301724

1 year extended warranty for GMX902 GG

2 year extended warranty for GMX902 GG

Add 1 year GMX902 GG Warranty Extension

1 year extended warranty for GMX901

2 year extended warranty for GMX901

Add 1 year GMX901 Warranty Extension

43

Purchasable Options

744 590

758 420

GSW475, Sensor upgrade from GRX1200 Lite to GRX1200 Classic

GSW619, Sensor upgrade from GRX1200 Pro to GRX1200 GG Pro, incl. permanent

GLONASS functionality. Only for GRX1200 Pro sensors with serial numbers between

355001 and 360000. For sensors outside this range, only GSW567 is required.

GMX900 Series vs GRX1200 Series - Differentiation

12 channels GPS, 1Hz L1 code/phase receiver

120 channels GPS, 20Hz L1/L2 code/phase receiver

+L5

120 channels GPS, GLONASS, Galileo, 20Hz L1/L2 code/phase receiver

- yes - yes -

Raw data logging onboard the receiver

RTK corrections directly from the receiver

Configuration and status display with web interface yes yes yes yes yes

- - - yes yes

-

-

-

-

-

- yes yes yes yes

RT and PP coordinate calculation using GNSS Spider

Advanced reference station firmware functionality

Number of serial ports

Advanced I/O ports yes

-

1

- yes

-

2

PPS yes

-

2

PPS yes yes

4

PPS. Event,

External

Oscillator,

Ethernet yes yes

4

PPS. Event,

External

Oscillator,

Ethernet

1.7 W 2.4 W 2.0 W 3.6 W 3.6 W yes yes yes yes yes yes yes yes yes yes

Power consumption

IP67

Operating temperature –40° to +65°C

4.2.2 Antennas

747 958

766 714

755 267

765 733

AX1203+ GNSS, GPS/GLONASS/Galileo Triple Frequency Antenna for all GRX1200 Series and GRX1200+ Series receivers.

AX1202 GG, Dual Frequency Antenna for GX1230 GG and GRX 1200 GG Pro Receiver

AT504 GG, GPS/GLONASS dual-frequency choke-ring antenna for GPS/GLONASS receivers. Dorne-Margolin antenna element, JPL design. Conforms to IGS "Typ T" specification for GPS antennas. For GX1220 / 1230, GRX1200 and GMX902 Receivers.

AR25, GNSS choke ring antenna for GPS/GLONASS/Galileo/Compass receivers. Includes L-

Band signals. Dorne-Margolin antenna element.

GVP601, Weather-protection radome for AT504 choke ring antenna.

GVP653, Weather-protection radome AR25 choke ring antenna.

667 140

765 734

4.2.3 GNSS Accessories

667 200

636 959

632 372

632 390

664 813

713 483

733 257

Antenna cable, 1.2 m

Antenna cable, 2.8 m

Antenna cable, 10.0 m

Antenna cable, 30.0 m

Antenna cable, 50.0 m

Antenna cable, 70.0 m

MCF256, CompactFlash card 256MB.

44

745 995

4.2.4 GNSS Spider

MCF1000, CompactFlash card 1GB.

All active RT Positioning Products and PP Positioning Products configured in GNSS Spider with the Send To option set to GeoMoS can be used in GeoMoS. Thus many GNSS sensors maybe connected using a single entry in the GeoMoS Sensor Manager.

Required Options for Real Time Monitoring (RT Positioning Products)

740 244

744 912

Leica GNSS Spider, GNSS Reference Station Software, general license, with documentation. Supports full receiver control and configuration, manual downloads and firmware upgrade. Not protected.

Spider, Positioning Site license.

Required for each GNSS site/sensor that shall be used for the Spider position processing. A minimum of two (2) of these licenses is needed for Positioning.

Required Options for Post Processed Monitoring (PP Positioning Products)

740 244

744 912

744 904

734 613

Leica GNSS Spider, GNSS Reference Station Software, general license, with documentation. Supports full receiver control and configuration, manual downloads and firmware upgrade. Not protected.

Spider, Positioning Site license.

Required for each GNSS site/sensor that shall be used for the Spider position processing. A minimum of two (2) of these licenses is needed for Positioning.

Spider, File Products Service (FPS) option. Provides automated data download and management for multiple sites with automated RINEX conversion, quality control, event logging, FTP transfer for distributing Spider product files on the Internet. Option includes one (1) site/sensor license. For more site/sensor licenses for a Spider FPS, order one or more "Spider, FPS Additional Site License" as required.

Spider, FPS Additional Site License. Required for each GNSS site/sensor that shall be used with Spider File Product Service in addition to the default one (1) site/sensor, which is included as standard.

Note: 744912 Positioning Site Licences are cumulative between Real-Time and Post-Processing Positioning Products.

For example, to use 10 sites simultaneously in both Real-Time and Post-Processing Products requires 20 Positioning

Site Licences. There is no limit to the number of Positioning Products (baselines) that may be configured if the number of sites used (including reference and rover sites) does not exceed the number of Positioning Site Licences.

For additional information see:

745 972 Equipment list “For GNSS Networks and Reference Stations”

4.2.5 GNSS QC

GNSS QC can be used as an alternative to GeoMoS as a low cost analyzer for use together with GNSS Spider for GPS-only monitoring. The Advanced Coordinate Analysis option includes support for 20Hz real time NMEA data, Spider post processing data, profiling, limit checks and messaging. GNSS QC can be also used for site selection and quality checking of the raw GNSS data.

Required Options for Analysis of Real Time and Post Processed Positioning Data from Spider

749 319

751 824

Leica GNSS QC, GNSS Reference Station software with documentation. For data analysis and quality control of GNSS reference station data. Dongle protected.

GNSS QC, Advanced Coordinate Analysis option. High speed calculation and graphing of displacement, messaging and limit checks for real time NMEA and GNSS Spider Post

Processing coordinate data. Dongle protected.

For additional information see:

745 972 Equipment list “For GNSS Networks and Reference Stations”

45

4.3 Levels

4.3.1 Supported Sensors

723 289

726 540

738 933

741 868

Customer Care Packages

DNA03, 0.3mm, precision digital level, magnetically-damped compensator, with user manual and container.

DNA10, 0.9mm, digital level, magnetically-damped compensator, with user manual and container.

SPRINTER 100M, 2.0mm, electronic level, with RS232 interface & internal memory, with user manual, 4 pcs AA dry cells and container.

SPRINTER 200M, 1.5mm, electronic level, with RS232 interface & internal memory, with user manual, 4 pcs AA dry cells and container.

A wide selection of comprehensive Customer Care Packages is available bundling Hardware

Maintenance, Software Maintenance, Customer Support and Extended Warranty. For more information about the CCP offering in your country please contact your local Leica Geosystems organization or distribution partner.

4.3.2 DNA Staffs

560 271

560 274

563 659

632 313

563 733

522 793

667 113

Invar bar code levelling staff GPCL3, 3m, with circular level.

Invar bar code levelling staff GPCL3, 3m, with circular level, with expansion coefficient certificate and length calibration certificate.

Invar bar code levelling staff GPCL2, 2m, with circular level.

Industrial bar code levelling staff GWCL92, 92 cm, invar staff with circular bubble and 2 interchangeable bases.

Invar bar code scale GWCL60, 60 cm

Dual face levelling staff GKNL4F, 13.3ft, 3 sections, code/ft graduation, with handles and circular bubble, in transport bag

Telescopic levelling staff GTL4C, 4m, aluminium, bar code/mm-graduation, with bull`seye bubble, in transport bag

4.3.3 Sprinter Staffs

741 882

741 883

741 884

741 885

741 886

746 613

746 614

GSS111, Dual face telescopic levelling staff, 5m, 4 sections, SPRINTER barcode / E-Scale cm-graduation, with circular bubble, in transport bag (Standard version).

GSS111-1, Dual face telescopic levelling staff, 5m (16.4ft), 4 sections, SPRINTER barcode / ft-graduation, with circular bubble, in transport bag, (Imperial version).

GSS112-3, Dual face telescopic levelling staff, 4m, 4 sections, SPRINTER barcode / E-

Scale cm-graduation, with circular bubble, in transport bag (UK version).

GSS111-2, Dual face telescopic levelling staff, 5m, 4 sections, SPRINTER barcode / 5mmgraduation, with circular bubble, in transport bag (Japan version).

GSS112-5, Dual face telescopic levelling staff, 4m, 4 sections, SPRINTER barcode / 2mmgraduation, with circular bubble, in transport bag (Spain version).

GSS112, Dual face telescopic levelling staff, 4m, 4 sections, SPRINTER barcode / E-Scale cm-graduation, with circular bubble, in transport bag (Standard version).

GSS122-3, Dual face telescopic (Fibreglass) levelling staff, 4m, 4 sections, SPRINTER barcode / E-Scale cm-graduation, with circular bubble, in carry case (UK version).

For additional information see:

761 756 Leica Original Accessories Program

46

4.4 Other Sensors

4.4.1 Inclination Sensors

The Nivel20 and Nivel200 are a series of highly precise inclination sensors from Leica Geosystems. The following instruments are supported.

576 198

576 199

NIVEL210, inclination sensor with RS232 interface

NIVEL220, inclination sensor with RS485 interface

575 869 Terminator for RS485. One terminator must be ordered and installed for each installation with Nivel220 sensors.

Other accessories

Inclination Sensors need to have mounting, shelters and cables.

749 031 GHT59, Wall Mounting Kit for NIVEL200

For cables refer to “ 6.6 Nivel210 / Nivel220 cables

”.

For additional information see:

749 597 "Leica Nivel210 and Nivel220 sensors Equipment List"

4.4.2 Meteo Sensors

667 726 STS DTM meteo sensor, combined pressure and temperature sensor, 2.0m cable with

Lemo 1

Other accessories

Meteo Sensors need to have mountings, shelters and cables.

Refer to “ 6.7 Meteo sensor cables ” to connect a meteo sensor.

Refer to “ 3.8 Setup a Meteo Sensor ”.

47

Power supply

The PC and the sensors need to have a permanent power supply.

Do not us an internal battery when using the Switchbox (744 794).

5.1 Continuous 12V Power supply for GPS1200 and NIVEL sensors

A permanent 12V power supply is needed for sensors

722 409 Power supply unit, for indoor use only, input 100V-240VAC 50-60HZ, output 12VDC, cable with 5-pin Lemo.

Standard mains/line cable select from following list.

Select power cords for 12V power supply unit 722 409:

731 772

731 773

Power Cord for Dual Bay Charger GKL24 or Power supply unit, US-Version.

Power Cord for Dual Bay Charger GKL24 or Power supply unit, EU-Version.

734 232

734 233

738 586

Power Cord for Dual Bay Charger GKL24 or Power supply unit, UK-Version.

Power Cord for Dual Bay Charger GKL24 or Power supply unit, AUS-Version.

Power Cord for Dual Bay Charger GKL24 or Power supply unit, CH-Version.

5.2 Continuous 12V Power supply for TPS sensors

A permanent 12V power supply is needed for sensors

749 279 GEV208, Power supply unit for TPS, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect power cables.

Standard mains/line cable select from the following list.

Select power cords for 12V power supply unit 749 279:

731 722

731 773

Power Cord, US-Version.

Power Cord, EU-Version.

734 232

734 233

738 586

Power Cord, UK-Version.

Power Cord, AUS-Version.

Power Cord, CH-Version.

48

Cables

A permanent power supply is needed during the measurements.

The communication between sensor and PC has to be permanently connected during the measurements.

6.1 Total station cables

439 038

734 698

759 257

GEV71, 4m car battery cable, connects TPS or GPS receiver (Lemo-1, 5 pin, female) to

12V car battery. (Note, for TPS e.g. the additional cable 734 698 is required.)

GEV187, Y-cable, connects TPS to PC (9-pin RS232 serial) and external battery, 2.0m.

GEV220, Y-cable, connects TM30/TS30 to PC (9-pin RS232 serial) and external battery,

2.0m.

6.2 GPS1200 / GMX902 cables

To connect two independent power supplies

733 298 GEV172, 2.8m Y-cable, connects GPS Receiver with two external power supplies.

To connect battery, car battery or alternate power supply

439 038 GEV71, 4m car battery cable, connects TPS or GPS receiver (Lemo-1, 5 pin, female) to

12V car battery. (Note, for GPS e.g. the 560 130 or 636 972 is required.)

560 130

636 972

1.8m cable, connects GEB171 external battery to GPS1200 receiver. Lemo-1, 5 pin, male to Lemo-1, 5 pin, male.

0.5m cable, connects GEB171 external battery to GPS1200 receiver. Lemo-1, 5 pin, male

722 411 to Lemo-1, 5 pin, male.

Cable with protection fuse to connect 12V power supply to GPS receiver.

To transfer data between sensor and spider

733 280 GEV160, 2.8m Data transfer cable. Connects GPS1200 receiver Ports 1, 2 and 3, RX1220 or GMX902 to PC for data transfer, firmware upload etc. Lemo 8 to 9 pin RS232 female serial connector.

563 809 GEV113, 2.8m Modem cable. Connects GPS receiver Ports 1, 2 and 3 to modem. Lemo 8

Pin to 9 Pin RS232 male serial connector.

733 290 GEV168, 5.0m cable, connecting GPS Receiver with Ethernet LAN / RJ45

6.3 GMX901 cables

750 073

743 389

GEV212, Interface Cable, 5m, GMX901 to unterminated, connects GMX901 to a custom installation.

GEV197, Y-Cable, 2.8m, GMX901 to RS232 and external Leica power supply.

49

6.4 Antenna cables

6.5 Level cables

667 200

636 959

632 372

632 390

664 813

713 483

Antenna cable, 1.2 m

Antenna cable, 2.8 m

Antenna cable, 10.0 m

Antenna cable, 30.0 m

Antenna cable, 50.0 m

Antenna cable, 70.0 m

439 038

734 698

GEV71, 4m car battery cable, connects TPS or GPS receiver (Lemo-1, 5 pin, female) to

12V car battery. (Note, for TPS e.g. the additional cable 734 698 is required.)

GEV187, Y-cable, connects TPS to PC (9-pin RS232 serial) and external battery, 2.0m.

6.6 Nivel210 / Nivel220 cables

To connect a Nivel210 directly to GPS1200

749 916 1.8m communication and connection cable, GEV209, Nivel210 to GPS1200

To connect a Nivel210 directly to PC

802 902 1.0m connection cable, connects Nivel210 sensor ports 1 or 2 to PC for data communication etc., Lemo-0 to 9 pin RS232 serial connector.

748 335 GEV204, Power supply-cable for NIVEL210 and NIVEL230. (Lemo -Lemo), 1.8m.

To connect a Nivel220

802 906

802 907

748 488

748 489

5.0m connection cable RS485. Connects two Nivel220 sensor ports 1 or 2, Lemo-0 to

Lemo-0.

20.0m connection cable RS485. Connects two Nivel220 sensor ports 1 or 2, Lemo-0 to

Lemo-0.

0.8m power supply cable, connects power supply unit 722 409 to RS232/RS485 converter, Lemo-0 to 2 wires to terminal strip.

1.8m communication cable, connects Nivel220 to RS232/RS485 converter, Lemo-0 to 4 wires to terminal strip.

50

6.7 Meteo sensor cables

To connect GEV187 and DTM meteo sensor

764 328 GEV222, Adapter cable DTM sensor, Lemo-1 (female) to Lemo-0 (female), 3.0m

734 698 GEV187, Y-cable, connects TPS to PC (9-pin RS232 serial) and external battery, 2.0m.

439 038 GEV71, 4m car battery cable, connects TPS or GPS receiver (Lemo-1, 5 pin, female) to

12V car battery. (Note, for DTM meteo sensor e.g. the additional cable 734 698 is required.)

6.8 Power cables

For power cables please refer to section “

5 Power supply

”.

6.9 Radio modem / mobile phones cables

For Satelline Radio modem, TCPS27 radio modem and GFU24 cables please refer to section “ 7 For transmitting data

”.

51

For transmitting data

7.1 Satelline Radio Modem, Radio Antennas and Accessories

Satelline Radio Modems

733 275

733 276

738 272

738 273

738 274

738 275

738 276

GFU14-0, Satelline 3AS radio modem (433.525 MHz, 25.0 kHz channel spacing, 0.5 W) already integrated into housing, fits on side of GPS Receiver. (User manual and CE-

Declaration of Conformity included).

GFU14-1, Satelline 3AS radio modem (406.425 MHz, 25.0 kHz channel spacing, 1.0 W) already integrated into housing, fits on side of GPS Receiver. (User manual and CE-

Declaration of Conformity included).

GFU14-2, Satelline 3AS radio modem (445.000 MHz, 12.5 kHz channel spacing, 1.0 W) already integrated into housing, fits on side of GPS Receiver. (User manual and CE-

Declaration of Conformity included).

GFU14-3, Satelline 3AS radio modem (443.000 MHz, 12.5 kHz channel spacing, 1.0 W) already integrated into housing, fits on side of GPS Receiver. (User manual and CE-

Declaration of Conformity included).

GFU14-4, Satelline 3AS radio modem (440.550 MHz, 25.0 kHz channel spacing, 0.5 W) already integrated into housing, fits on side of GPS Receiver. (User manual and CE-

Declaration of Conformity included).

GFU14-5, Satelline 3AS radio modem (458.150 MHz, 12.5 kHz channel spacing, 1.0 W) already integrated into housing, fits on side of GPS Receiver. (User manual and CE-

Declaration of Conformity included).

GFU14-6, Satelline 3AS radio modem (439.8625 MHz, 12.5 kHz channel spacing, 1.0 W) already integrated into housing, fits on side of GPS Receiver. (User manual and CE-

Declaration of Conformity included).

Select according to frequency of radio modem

639 964

667 243

GAT1, Gainflex radio antenna, frequency range 400-435MHz.

GAT2, Gainflex radio antenna, frequency range 435-470MHz.

Programming Cable for Satelline Radio Modem

733 297 GEV171, 1.8m cable to program, the Satelline 3AS radio modem inside the GFU14 housing.

7.2 TCPS27 Radio Modem and Accessories

TCPS27 Radio Modems

734 161

734 162

TCPS27 B, radio modem (base), with antenna, user manual. Used as radio modem for

TPS1200 (frequency range 2400 - 2483 Mhz).

TCPS27 R, radio modem (remote), with antenna, user manual. Used as external radio for

PC (frequency range 2400 - 2483 MHz).

Cables for TCPS27 Radio Modems

734 697

771 057

734 699

---

GEV186, Y-cable, connects TCPS27 to TPS/1000/1100/1200 and external battery, 1.8m.

GEV236, Y-cable, connects TM30/TS30 to TCPS radio and external battery, 2m.

GEV188, Y-cable, connects TCPS27 to PC (9-pin RS232 serial) and external battery, 1.8m.

Coaxial cable, connects antenna to TCPS27

Important ƒ Use the TCPS27 ConfigTool from the CD to set the correct baud rate and link number.

ƒ Enable the RTS mode in the GeoMoS Monitor software.

52

7.3 Mobile Phones and Accessories

750 242

667 237

733 297

GFU24, Housing with Siemens MC75 GSM/GPRS Module (Quad-Band GSM

850/900/1800/1900 MHz).

Antenna for 900/1800 MHz mobile network.

GEV171, 1.8m cable to program, the Satelline 3AS radio modem inside the GFU14 housing. Also used to connect GFU17 to PC.

53

Other Accessories

8.1 Switchbox

Essential tool for permanent monitoring, supports cold boot for TPS

744 793

772 630

Switchbox with a 2.0m cable for TPS1000/ TPS 1100/ TPS 1200 (Lemo 0) and GeoMoS.

GDZ 68, Switchbox with a 2.0m cable for TM30/TS30 (Lemo 1) and

GeoMoS

54

Third party devices

Leica Geosystems tested and uses the following devices in local Leica monitoring solutions:

9.1 RS232/RS485 converter

I-7520 RS232 to RS485 converter for Nivel220 sensors http://www.icpdas.com

http://www.icpdas.com/products/Remote_IO/i-7000/i-7520.htm

This is a product of ICP DAS Co.

9.2 RS232/Ethernet converter

Model 58631,

Model 58633

1 serial port

3 serial ports

RS232 to Ethernet converter for total stations and Nivel210 sensors http://www.wut.de

http://www.wut.de/e-58631-ww-daus-000.php

http://www.wut.de/e-58633-ww-daus-000.php

This is a product of Wiesemann & Theis GmbH.

MOXA5110

1 serial port

RS232 to Ethernet converter for total stations and Nivel210 sensors http://www.moxa.com

http://www.moxa.com/Product/NPort_5110.htm

Use the –T models for outdoor installations

This is a product of Moxa Inc.

9.3 Wireless modem

NB2210 The NB2210 connects Ethernet enabled equipment to the internet over a mobile network (GSM/GPRS/EDGE) http://www.netmodule.com/en/ http://www.netmodule.com/en/products/nb/nb2210.aspx

This is a product of NetModule Inc.

55

9.3.1 Remote Setup of a Total Station with a Wireless Modem (e.g. NB2210)

Internet

734 698

759 257

664 662

757 129

764 824

439 038

NB

749 279

744 793

772 630

Mini Adapter

Select Total Station

664 662

757 129

764 824

TCA2003, 0.5"(0.15mgon) automatic precision total station, with laser plummet, 2 control panels, accessories, user manual and container.

TM30 0.5”, 0.15gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.

TM30 1”, 0.3gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.

Select Cables and Switchbox

744 793 Switchbox with cable 2.0m for TPS/1000/1100/1200 and GeoMoS. Supports cold boot for TPS

772 630

734 698

759 257

Mini adapter

Gender changer

(important 24/7 hours/day monitoring).

GDZ 68, Switchbox with a 2.0m cable for TM30/TS30 (Lemo 1) and GeoMoS. Supports cold boot for

TPS (important 24/7 hours/day monitoring).

GEV187, Y-cable, connects TPS/1000/1100/1200 to PC (9-pin RS232 serial) and external battery, 2.0m.

GEV220, Y-cable, connects TM30/TS30 to PC (9-pin RS232 serial) and external battery, 2.0m.

Null modem, DB9 male to DB9 female. Refer to “ 9.6.2 Mini adapter ”.

Gender changer, DB9 male to DB9 male. Refer to “

9.6.2 Mini adapter

”.

Select Power

439 038

749 279

GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.

GEV208, Power supply unit for TPS, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to TPS.

Select power cords for 12V power supply unit 749 279. Refer to “

5 Power supply ”.

Select Wirless Modem

NB2210 The NB2210 connects Ethernet enabled equipment to the internet over a mobile network

(GSM/GPRS/EDGE). Refer to “

9.2 Wireless modem

”.

Select Software

GeoMoS Monitor / Analyzer

Refer to “ 1 GeoMoS Modules

56

9.4 Digital IO card

Web IO 2x

Digital Input, 2x

Digital Output

The Web IO (2x Digital Input, 2x Digital Output) connects digital input and output ports of industrial 24V technology to the network .

http://www.wut.de

http://www.wut.de/e-57633-ww-daus-000.php

This is a product of Wiesemann & Theis GmbH.

9.5 Datalogger

CR1000

Multiplexer

9.6 Wireless Ethernet Radio

ELPRO 805U-E

CR1000 MEASUREMENT AND CONTROL MODULE C/W CR1000WP

AM16/32A 16/32 CHANNEL RELAY MULTIPLEXER C/W SPARK GAPS http://www.campbellsci.com/cr1000 http://www.campbellsci.com/index.cfm

This is a product of Campbell Scientific Ltd.

The ELPRO 805U connects serial or Ethernet devices by industrial wireless radio modems. http://www.elprotech.com/ http://www.elprotech.com/index.cfm?content=280

This is a product of ELPRO Technologies.

57

9.6.1 Remote Setup of a Total Station with Radio (ELPRO 805U-E)

722 409

ELPRO antenna

748 488

ELPRO Mini Adapter

ELPRO antenna

Ethernet cable

ELPRO

734 698

759 257

664 662

757 129

764 824

439 038

748 488

722 409

749 279

744 793

772 630

Select Total Station

664 662

757 129

764 824

TCA2003, 0.5"(0.15mgon) automatic precision total station, with laser plummet, 2 control panels, accessories, user manual and container.

TM30 0.5”, 0.15gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.

TM30 1”, 0.3gon, total station with reflectorless EDM (R1000), automatic target recognition, communication sidecover, internal memory, laser plummet, 1 keyboard, standard applications, user manuals, and upright container.

Select Cables and Switchbox

744 793

772 630

734 698

759 257

748 488

Switchbox with cable 2.0m for TPS/1000/1100/1200 and GeoMoS. Supports cold boot for TPS

(important 24/7 hours/day monitoring).

GDZ 68, Switchbox with a 2.0m cable for TM30/TS30 (Lemo 1) and GeoMoS. Supports cold boot for

TPS (important 24/7 hours/day monitoring).

GEV187, Y-cable, connects TPS/1000/1100/1200 to PC (9-pin RS232 serial) and external battery, 2.0m.

GEV220, Y-cable, connects TM30/TS30 to PC (9-pin RS232 serial) and external battery, 2.0m.

0.8m power supply cable, connects power supply unit 722 409 to RS232/RS485 converter, Lemo-0 to

2 wires to terminal strip.

Null modem, DB9 male to DB9 male. Refer to “

9.7.2 Mini adapter

”. Mini adapter

Ethernet

Refer to “ 9.7.1 Cables ”.

cable

Select Radio Modem

ELPRO Interconnect

9.6 Wireless

Ethernet Radio ”.

Select Power

439 038

749 279

722 409

GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.

GEV208, Power supply unit for TPS 2003, for indoor use only, input 100V-240VAC 50-60HZ, output

12VCD, cable with 5-pin Lemo to connect to TPS.

Power supply unit, for indoor use only, input 100V-240VAC 50-60HZ, output 12VDC, cable with 5-pin

Lemo.

58

Select power cords for 12V power supply unit 722 409 and 749 279. Refer to “ 5 Power supply

”.

Select Software

GeoMoS Monitor / Analyzer

Refer to “ 1 GeoMoS Modules

59

9.6.2 Remote Setup of a GMX902 with Radio (ELPRO 805U-E)

Ethernet cable

748 488

ELPRO antenna

ELPRO antenna

ELPRO

ELPRO

733 280

Mini Adapter

722 409

748 488 758 600

722 409

722 409

Select Receiver

758 600 GMX902 GG, GNSS Dual Frequency Receiver for Monitoring Applications.

Select Cables

733 280

748 488

GEV160, 2.8m Data transfer cable. Connects GPS1200 receiver Ports 1, 2 and 3, RX1220 or GMX902 to

PC for data transfer, firmware upload etc. Lemo 8 Pin to 9 pin RS232 female serial connector.

0.8m power supply cable, connects power supply unit 722 409 to RS232/RS485 converter, Lemo-0 to

2 wires to terminal strip.

Null modem, DB9 male to DB9 male. Refer to “

9.7.2 Mini adapter

”. Mini adapter

Ethernet cable

Refer to “ 9.7.1 Cables ”.

Select Antenna

747 958

766 714

755 267

765 733

AX1203+ GNSS, GPS/GLONASS/Galileo Triple Frequency Antenna for all GRX1200 Series and GRX1200+

Series receivers.

AX1202 GG, Dual Frequency Antenna for GX1230 GG and GRX 1200 GG Pro Receiver

AT504 GG, GPS/GLONASS dual-frequency choke-ring antenna for GPS/GLONASS receivers. Dorne-

Margolin antenna element, JPL design. Conforms to IGS "Typ T" specification for GPS antennas. For

GX1220 / 1230, GRX1200 and GMX902 Receivers.

AR25, GNSS choke ring antenna for GPS/GLONASS/Galileo/Compass receivers. Includes L-Band signals.

Dorne-Margolin antenna element.

GVP601, Weather-protection radome for AT504 choke ring antenna. 667 140

765 734 GVP653, Weather-protection radome AR25 choke ring antenna.

Select Antenna Cables

632 372

632 390

Antenna cable, 10 m

Antenna cable, 30 m

60

Select Radio Modem

ELPRO Interconnect

9.6 Wireless

Ethernet Radio ”.

Select Power

722 409 Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.

Select power cords for 12V power supply unit 722 409. Refer to “

5 Power supply ”.

Select Software

Leica GNSS Spider

Refer to “ 4.2.4 GNSS Spider ”

Optional Software

GeoMoS Monitor / Analyzer

Leica GNSS QC

Refer to “ 1 GeoMoS Modules

Refer to “ 4.2.5 GNSS QC ”

Note: If you connect more than one GNSS receiver to GeoMoS to use for monitoring we recommend GNSS connection to the Leica Spider software. GeoMoS supports an interface to Leica GNSS Spider software (order GNSS Spider and accessories separately)

61

9.6.3 Remote Setup of a GMX901 with Radio (ELPRO 805U-E)

722 409

755 231

743 389

Ethernet cable

ELPRO antenna

ELPRO

ELPRO antenna

722 409

748 488

748 488

ELPRO

Mini Adapter

722 409

Select Receiver

755 231

Select Cables

743 389

748 488

GMX901, GPS Smart Antenna for Monitoring Applications

GEV197, Y-Cable, 2.8m, GMX901 to RS232 and external Leica power supply.

0.8m power supply cable, connects power supply unit 722 409 to RS232/RS485 converter, Lemo-0 to

2 wires to terminal strip.

Null modem, DB9 male to DB9 male. Refer to “

9.7.2 Mini adapter

”. Mini adapter

Ethernet

Refer to “ 9.7.1 Cables ”.

cable

Select Radio Modem

ELPRO Interconnect

9.6 Wireless

Ethernet Radio ”.

Select Power

439 038

722 409

GEV71, 4m car battery cable, connects TPS or GPS receiver to 12V car battery.

Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.

Select power cords for 12V power supply unit 722 409. Refer to “

5 Power supply ”.

Select Software

Leica GNSS Spider

Refer to “ 4.2.4 GNSS Spider ”

Optional Software

GeoMoS Monitor / Analyzer

Leica GNSS QC

Refer to “

Refer to “

1 GeoMoS Modules

4.2.5 GNSS QC ”

62

9.6.4 Remote Setup of a Nivel210 with Radio (ELPRO 805U-E)

Ethernet cable

ELPRO antenna

ELPRO

576 198

ELPRO antenna

802 902

ELPRO

Mini Adapter

748 488

722 409

748 335

722 409

Select Sensor

576 198

Select Cables

748 335

802 902

748 488

Mini adapter

Ethernet cable

Select Radio Modem

NIVEL210, inclination sensor with RS232 interface

GEV204, Power supply-cab.f. NIVEL210/230

Cable, PC- NIVEL210, (Lemo-RS232), 1m

0.8m power supply cable, connects power supply unit 722 409 to RS232/RS485 converter, Lemo-0 to

2 wires to terminal strip.

Null modem, DB9 male to DB9 male. Refer to “ 9.7.2 Mini adapter ”.

Refer to “ 9.7.1 Cables ”.

ELPRO Interconnect

9.6 Wireless

Ethernet Radio ”.

Select Power

722 409 Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.

Select power cords for 12V power supply unit 722 409. Refer to “

5 Power supply ”.

Select Software

GeoMoS Monitor / Analyzer

GNSS QC

Refer to “

Refer to “

1 GeoMoS Modules

4.2.5 GNSS QC ”

Important ƒ Use the NivelTool software from the CD to set the correct Nivel ID and baud rate.

63

9.6.5 Remote Setup of multiple Nivel220 with Radio (ELPRO 805U-E)

Ethernet cable

ELPRO antenna

ELPRO

748 488

567 199

722 409

567 199

ELPRO antenna

ELPRO

748 498

567 199

802 906 or

802 907

802 906 or

802 907

575 869

748 488

722 409

Select Sensor

576 199 NIVEL220, inclination sensor with R4852 interface

Select Cables

748 488

748 498

802 906

802 907

575 869

Ethernet cable

Select Radio Modem

0.8m power supply cable, connects power supply unit 722 409 to RS232/RS485 converter, Lemo-0 to

2 wires to terminal strip.

1.8m communication cable, connects Nivel220 to RS232/RS485 converter, Lemo-0 to 4 wires to terminal strip.

5.0m connection cable RS485. Connects two Nivel220 sensor ports 1 or 2, Lemo-0 to Lemo-0.

20.0m connection cable RS485. Connects two Nivel220 sensor ports 1 or 2, Lemo-0 to Lemo-0.

Terminator 120 Ohm, for RS485 Bus

Refer to “ 9.7.1 Cables ”.

ELPRO Interconnect

9.6 Wireless

Ethernet Radio ”.

Select Power

722 409 Power supply unit for GPS receiver, for indoor use only, input 100V-240VAC 50-60HZ, output 12VCD, cable with 5-pin Lemo to connect to GPS.

Select power cords for 12V power supply unit 722 409. Refer to “

5 Power supply ”.

Select Software

Important

GeoMoS Monitor / Analyzer

GNSS QC

ƒ

Refer to “

Refer to “

1 GeoMoS Modules

4.2.5 GNSS QC ”

Use the NivelTool software from the CD to set the correct Nivel ID and baud rate.

64

9.7 Accessories

9.7.1 Cables

9.7.2 Mini adapter

RS232 cable or so-called DB9 cable

Ethernet cable

CAT6

Shielded cable

Terminal strip

Mount in a box

Null modem or

RS232 reverser

Specification

A null modem (or RS232 reverser) reroutes wiring.

A null modem crosses pins 2 and 3, so that pin 2 on one side is connected to pin 3 on the other.

Gender changer A gender changer is a small hardware device or adapter that is used to correct the connector mismatches of cables.

65

Leica Geosystems AG

Heerbrugg, Switzerland www.leica-geosystems.com

Whether you monitor the movement of a volcanic slope, the structure of a long bridge or track the settlement of a dam; whether you measure, analyse and manage the structures of natural or man-made objects: the monitoring systems by Leica Geosystems provide you with the right solution for every application.

Our solutions provide reliable, precise data acquisition, advanced processing, sophisticated analysis and secure data transmission.

Using standard interfaces, open architectures and scaleable platforms, the solutions are customizable to meet individual requirements – for permanent and temporary installations, for single sites and monitoring networks.

When it has to be right.

Illustrations, descriptions and technical specifications are not binding and may change.

Printed in Switzerland – Copyright Leica Geosystems AG, Heerbrugg, Switzerland, 200 8.

729323en –

V1.09 – INT

advertisement

Related manuals

advertisement