MRX/OS Control Program
and Data Management Services
Extended Reference Manual
2200.002
SJONPOId
ХеБОМЕЙМ
W9)SÁS Jo1ndwu0o”
December 1972 Edition
Requests for copies of Memorex publications should be made
to your Memorex representative or to the Memorex branch
office serving your locality.
A reader's comment form is provided at the back of this
publication. If the form has been removed, comments may be
addressed to the Memorex Corporation, Publications Dept.,
8941 — 10th Ave. No. (Golden Valley) Minneapolis,
Minnesota 55427.
O 1972, MEMOREX CORPORATION
PREFACE
The MRX/OS Control Program and Data Management
Services are discussed in two separate documents,
each designed for a specific type of input/output
(1/0) level user. The Basic Reference manual contains
information at the logical 1/0 level of processing,
where the blocking and deblocking of data is done for
the user. This document, the Extended Reference
manual, is designed for the block and physical 1/0
level user. Block 1/0 level processing recognizes no
logical records; therefore, all data is read or written as
a data block. The physical 1/0 level of processing
allows the user to do his own processing of data.
Chapter 7 of this document contains all the macros
required for block and physical 1/0 level processing.
Appendix B contains the expansions of these macros
with the standard system suffixes listed.
Related information may be found in the following
documents.
o MRX/OS Control Language Services,
Extended Reference
o MRX/OS Control Program and Data
Management Services, Basic Reference
e MRX/OS Assembler Reference
TABLE OF CONTENTS
Section
INTRODUCTION
Environment
Description
Input/Output Levels
General
Logical Input/Output
Block Input/Output
Physical Input/Output
Implementation Method
DATA STRUCTURES
Files and Records
Labels
Tape Labels
Disc Label
Disc Storage Catalogs
Tables
File Description Table
Buffer Description Table
BLOCK INPUT/OUTPUT
Introduction
General Rules
Block Input/Output Coding
Block Reading
Block Writing
Block Positioning
Device Control Commands
Space Management and File Control
Processing Considerations
Priority
End Conditions
Processing Multi-Volume Files
Sense Information
=. Request Termination
Error Processing
PHYSICAL INPUT/OUTPUT
Introduction
Physical Input/Output Coding
Defining and Opening Devices
Performing the Physical 1/0 Operation
Page
1-1
uv #* |
N aa = —
1-2
2-3
2-12
2-12
2-12
3-1
3-1
3-1
3-2
3-2
3-2
3-3
3-3
3-3
3-3
3-4
3-4
3-4
3-4
4-1
4-1
4-1
4-1
4-1
TABLE OF CONTENTS (Continued)
Section
4 (cont) Basic Method
Sharing a PCB
Sharing an EXCP
Overlapped Operation
Physical 1/0 Restrictions
Error Processing
Example of Physical 1/0 Program
5 CONTROL PROGRAM SERVICES
Introduction
Service Request Control
Inter Step and Control Language Communication
Finding Partition Size
Reading Data from //PAR Cards
Writing to the SYSOUT File
6 INTERACTION OF DATA MANAGEMENT AND THE CONTROL LANGUAGE
7 MACROS
Data Management
Block 1/0 Level Declarative Macro
DEFLB — Define File Label
Block 1/0 Level and Physical 1/0 Level Executive Requests
Space Management Macros
ALLOC - Allocate Space
EXPND — Add Mass Storage Space
PURGE — Release Disc File Space
File Control
OPEN — Open File for Data Transmission
CLOSE — Close File for Data Transmission
CLOVE — Close Volume
I/O Service Macro
LABRTN — Return File Label Information
Block Input/Output Macros
Read
Write
Magnetic Tape and Disc
Line Printer
Card Punch
POSITN — Change Current Block Number
CNTRL — Hardware Control Operation
STATUS — Report of Status
TYPE — Device and File Type
RESET — Reset Exception Conditions
Physical Input/Qutput Macros
EXCP — Input/Output Action
vi
Page
4-1
4-1
4-3
4-3
4-3
4-3
5-2
7-1
7-2
7-2
7-2
7-2
7-5
7-6
7-6
7-7
7-8
7-9
7-9
7-10
7-10
7-11
7-12
7-12
7-12
7-12
7-13
7-15
7-15
7-21
7-22
7-22
Section
7 (cont)
TABLE OF CONTENTS (Continued)
Command
COMMAND Macro for Basic Data Channel (Unit Record Devices and
Magnetic Tape) |
COMMAND Macro for DCABLE Operation
COMMAND Macro for a DCSEEK Operation
COMMAND Macro for a DCSRCH Operation
COMMAND Macro for a DCREAD Operation
COMMAND Macro for a DCWRIT or DCFWRIT Operation
COMMAND Macro for a RESTORE Operation
COMMAND Macro for a DCJUMP Operation
Control Program Macros
WAIT — Wait for Service Request Completion
Delay — Suspend Program Execution
INFORM — Service Request Completed
POST — Create Compressed Communication Byte
RPOST — Expand from Communication Byte
SETCOM — Transfer to Job Control Table
GETCOM — Transfer from Job Control Table Communication Area
ACCEPT — Read //PAR Card
DISPLAY — Write Message on SYSOUT
MEMLIM — Identify Partition Limit
SETIF — Post Code for Control Language Test
HALT — Terminate Program
EHALT - Terminate Program
ABEND -— Terminate Program Abnormally
TIME — Retrieve Time of Day
SDATE -- Retrieve System Data
JDATE -- Retrieve Job Date
Console Communication Macros
CONSOLE — Transmit Message to Console and Optionally Receive Reply 7-38
APPENDIX A
APPENDIX B
APPENDIX C
APPENDIX D
APPENDIX E
APPENDIX F
MESSAGE — Set Up Message Format
Generation of an Output Message
Generation of a Reply Buffer
PACK CATALOG AND CENTRAL CATALOG FORMATS
SERVICE REQUEST MECHANISM AND MACRO EXPANSIONS
ERROR RECOVERY
GAP SPECIFICATIONS
DISC TRACK FORMAT
INDEX — BLOCK SIZE FOR INDEXED FILES
vil
Page
7-23
7:24
7-24
7-24
7-27
7-28
7-29
. 7-30
7-30
7-30
7-31
7-31
7-32
7-32
7-33
7-33
7-34
7-35
7-35
7-36
7-36
7-37
7-37
7-37
7-37
7-37
7-37
7-38
7-38
7-38
A-1
B-1
C-1
D-1
E-1
F-1
LIST OF FIGURES
Figure
2-1
2-2
2-3
3-1
3-2
4-1
4-2
4-3
4-4
7-1
Standard Tape Volume Label
Standard Tape File Label
Disc Label
Block 1/0 Program to Read Cards and Print
Block 1/0 Program to Read Cards into Disc File
Basic Method for Physical 1/0
Sharing a PCB
Sharing an EXCP
Physical 1/0 Program to Read Cards and Print
Card Image/Storage Relationship
LIST OF TABLES
Table
2-1
2-2
2-3
2-4
2-5
2-6
2-7
2-8
2-9
2-10
2-11
31
6-1
71
7-2
7-3
7-4
7-5
Name Element Format
Attribute Element Format
Space Element and Space Element Continuation Format
Volume Element and Volume Element Continuation Format
File Description Table Format
Disc Device Format
Magnetic Tape Device Format
Unit Record Device Format
Buffer Description Table Format for Sequential Files
Buffer Description Table Format for Relative Files
Buffer Description Table Format for Indexed Files
Assumed Block Numbers
Summary of Data Management and Control Language Interaction
Returned Information Format
Status Word for Basic Data Channel Operations
Status Word For Disc Channel Operations
Bit Significance
Peripheral Device Basic Hardware Operation Codes
viii
Page
2.2
2-2
2-3
3-5
3-6
4-2
4-2
4-2
4-4
7-11
Page
2-4
2-6
2-8
2-10
2-13
2-16
2-18
2-19
2-20
2-24
2-29
3-2
6-2
7-16
7-19
7-20
7-22
7-25
ENVIRONMENT
The logical, block and physical input-output facilities
and control program services described in this manual
are all available on the MRX/OS nominal system.” All
except for those flagged are also available on the
MRX/OS minimal system.t Since MRX/OS is a
disc-resident system, a minimum of one disc drive is
required for the system disc pack.
DESCRIPTION
The services described in this manual are those
provided by the central part of the operating
systemTT. Access to these services, which are mainly
concerned with input/output processing, is through
system macro instructions.
*The nominal system has a minimum main storage size of
24K bytes, including a system region of 10K bytes.
tThe minimal system has a minimum main storage size of
16K bytes, including a system region of 8K bytes.
TT Other operating system services, such as job control, link
editing and library utilities, are described in separate
manuals,
1. INTRODUCTION
INPUT/OUTPUT LEVELS
GENERAL
An Assembly Language programmer may code his
input/output implementation at three different
levels: the logical, block, and physical levels. The
logical level is processed by the Data Management
system while the block and physical levels are
processed directly by the system's basic input/output
routines {upon which Data Management depends).
The logical level, the highest level, is the easiest to
use. The block level provides greater flexibility but is
still dependent on the standard system data file
structures. The physical level is the most involved,
regarding coding, but provides the greatest flexibility,
including independence from the system's file
structures.
LOGICAL INPUT/OUTPUT
Logical input/output coding (described in the Control
Program and Data Management Services, Basic
Reference and in Section 2 of this book) is normally
employed in situations where no special handling of a
condition such as end-of-file is required and the
amount of available storage space is not especially
restricted (though careful coding will still enable the
programmer to economize on storage space). The
chief advantage of logical input/output is the
simplicity of coding for most common input/output
applications.
1-1
BLOCK INPUT/QUTPUT
Block input/output coding (described in Section 3)
enables the programmer to create an object program
“smaller than would result from logical input/output,
since the large general-purpose GET/PUT subroutines
are not included. When the user's input/output
application is limited to a certain particular type of
operation, block input/output produces a smaller,
more efficient program but involves more work in
writing the code. Block input/output is also necessary
in the case where some special handling of abnormal
conditions is required.
PHYSICAL INPUT/QUTPUT
Physical input/output coding (described in Section 4)
is used where the user desires to create and process
his own special external data structures for some
special application, or where some special
input/output device such as a plotter is being used.
(The standard system files may also be processed by
physical input/output if desired, though this would
rarely be done in practice.)
IMPLEMENTATION METHOD
Ultimately, whether logical, block, or physical 1/0 is
being used, all input/output implementation is
performed by the system's input/output drivers. The
basic mode of communication with the drivers is
always the same; it involves supplying them with a
“command program”, which is a contiguous group of
command control blocks, each one calling for the
execution of a specific 1/0 operation.
The physical input/output user must create these
command programs himself with physical
input/output macros, and issue do input/output
macros which instruct the system to execute them.
The block input/output user, on the other hand,
simply codes the appropriate block input/output
macro: in this case the system builds the command
program and executes it. At the logical input/output
level (data management) the system performs certain
pre- or post-processing of data connected with the
logical data file structure before or after it passes
control to the block input/output level for
implementation of the actual data transfer.
1-2
The structure of records, labels, and files is discussed
in connection with their use. The Control Program
and Data Management Services, Basic Reference
discusses the general data structures. This manual
gives the specific description of labels and tables.
FILES AND RECORDS
Data Management supports records that have the
common stored data format, which include logical
record headers and may include space headers in each
block of data. If the block 1/O user elects to use the
common stored data format, he must specify CSD =
YES on the Control language //DEFINE card to
allocate a block size sufficient for the required
headers. The control information (record headers and
space headers) is managed by Data Management for
logical 1/0 users. However, block 1/0 level or physical
I/O level users must generate or process the contro!
information if the common stored data format is
used. The common stored data format is used only
for data located in mass storage; thus data stored on
unit record devices does not have this format; and
this format is not applied to such data by the block
1/O level READ function (Section 7, Macros).
Records may be variable length or fixed length
limited only by file organization and devices; that is,
only fixed-length records can be used for unit record
devices.
Three file organizations, which produce a variety of
applications, are available for the user: sequential,
relative, and indexed. At the logical 1/0 level, two
access methods are provided — sequential and
random. At the block 1/O level, each access is by
specified block (random) or by implied next block
(sequential, by adding one to the access count).
Sequential access is provided for all three file
organizations; however, random access is limited to
relative or indexed files.
2. DATA STRUCTURES
A more detailed discussion of file and record
structures is in the Control Program and Data
Management Services, Basic Reference.
LABELS
Two types of identification are associated with a disc
pack or tape reel: external (such as a sticker) and
internal (labels). This section is concerned with the
internal identification, namely the labels.
The internal identification serves two purposes.
1. Labels protect files from careless mistakes
resulting from the user's disregard for external
labeling.
2. Labels specify the location of data on files and
store variable file information.
Tapes are identified by both volume and file labels;
the disc files have volume labels and central and/or
pack catalogs.
TAPE LABELS
The MRX 40 and 50 Systems have two types of tape
labels: volume labels and file labels.
The volume label is found at the beginning of a tape
reel and the file label at the beginning of a file. Tape
marks separate files and their associated labels on a
tape reel.
The volume label (Figure 2-1) is identified by the
characters, VOL, found in the first three positions.
The volume label number is always 1 for
compatibility with 18M. The volume serial number
occupies positions 4 through 9 and identifies the
volume: and a unique owner name and address code
identifies the installation.
2-1
BYTE 0
: VOL
3
4
VOLUME IDENTIFIER
9
wl 0
1 STATE OF VOLUME La! 1
12 POINTER TO VTOC (VOLUME 2
| TABLE OF CONTENTS) ONLY ON
21 CONVERTED IBM PACKS
22 DEVICE TYPE
23
2 PACK CATALOG ADDRESS
26
OWNER
(1-56 BYTES EBCDIC)
79
———l
Figure 2-1. Standard Tape Volume Label
The standard tape file label (Figure 2-2) provides
information concerning the user's file such as creation
and expiration dates, file label number, file name, and
sequence number,
The label identification field identifies the type of
standard label with a three letter abbreviation. Three
types supported by the system are header labels
(HDR), end-of-file labels (EOF), and end-of-volume
labels (EOV). The file serial number found in
positions 22-27 is identical to the volume serial
number in the volume label. The volume sequence
number identifies the order of the volume of data
records in a multi-volume logical file. The block
count provides the number of physical records
written in a file at creation.
DISC LABEL
Disc files must be labeled with volume and actual file
identification (Figure 2-3). The disc pack volume
label is written by the Pack Initialize Utility Routine
(MRX/OS Utility Programs Reference). The volume
label identifies the volume; gives the state of the
volume — unrestricted (0), restricted (1), or locked
(2), — device type, owner; and gives the starting track
address of the pack catalog for this volume. The
actua! file identification is found in the disc catalogs.
2-2
BYTE
- > Nos
21
26
27
30
nf
41
LABEL IDENTIFICATION
FILE LABEL NUMBER
FILE NAME
FILE SERIAL NUMBER
—
VOLUME SEQUENCE NUMBER
wl
CREATION DATE
EXPIRATION DATE
- B&R -
BLOCK COUNT
Figure 2-2. Standard Tape File Label
HDR
EOF
EOV
— BYTE
VOL
VOLUME LABEL NUMBER —— EQUALS 1
' >“ N =» СЭ
VOLUME SERIAL NUMBER
oy o
41
. OWNER NAME
AND
. ADDRESS CODE
51 €
79 E
Figure 2-3. Disc Label
DISC STORAGE CATALOGS
The space management routines, in performing their
functions, maintain the central catalog and pack
catalogs on disc. The pack catalog, existing on each
volume, contains an entry for each file occupying
space on the volume. The entry identifies the file and
describes the space occupied by the file.
The pack catalog entry is generally divided into the
following three elements, each having the form of a
common stored data format.
e Name element, to identify the file
® Attribute element, to detail various
characteristics of the file
® Space element, to define the space occupied
by the file
The central catalog, existing once for a system,
contains an entry for each file cataloged in the
system. The entry identifies the file and describes the
volumes occupied by the file. The central catalog also
consists of three elements:
e Name element, to identify the file
e Attribute element, to detail characteristics
of the file
® Volume element, to define the volumes
occupied by the file
Allowance is made in the catalog structure for
overflow from a pack catalog space element or central
catalog volume element. These elements are known as
element continuations: space element continuation
- and volume element continuation.
Tables 2-1 through 2-4 explain format of the four
basic elements and the two element continuations. At
the beginning of each table is an illustration of the
specific element format. Appendix A contains
detailed discussion of the pack catalog and central
catalog formats.
2-3
10
12
36
40
42
46
48
Table 2-1. Name Element Format
Standard Control Bytes
Next Name Element
|
Previous Name Element
Name Length |
File Name and Qualifier
Number of Pointers
Pointer Identification
Pointer
Pointer Identification |
Pointer
Pointer Identification |
Pointer
Bytes Bit Description
0 0,1 Data type (binary)
01 User data
10 System data
11 Both user and system data
2-5 Reserved, always 0000,
6,7 Count of length bytes, always 10,
1 Relative record number within block, with value O to m-1 for m records
2,3 Length bytes, giving length of the record (in bytes) with the measurement being exclusive of the control bytes
4-6 Thread to the next name element {in collating sequence). This thread is expressed in a BBR format, where BB
is the relative block number (value 1 to n for n blocks) and R is the relative record number (value O to m-1 for
the next name element's position within block BB. BBR=0 for the thread in the last name element of the chain.
79 Thread to the previous name element within the catalog file. BBR=0 for the first name element of the chain.
10 Name length, giving the count of bytes in the File Name and Qualifier field. The total count must
be even and not exceed 26.
2.4
Table 2-1. Name Element Format (Continued)
Bytes Bit Description
11-36 File Name and Qualifier, containing a file name consisting of a maximum of 17 EBCDIC characters (alphabetic,
numeric, and dash), a period separator, and a qualifier consisting of a maximum of eight alphanumeric charac-
ters. For name elements related to a system catalog file, the EBCDIC requirement is lifted.
37 Number of element pointers which follow within the name element.
38,42, Pointer identification, expressed in hexadecimal within one byte and identifying the pointer, where * denotes
46 pertinent name elements within an entry in the pack catalog, and ** denotes pertinent name elements within
an entry in the central catalog. Other pointers are pertinent in both the pack and central catalogs.
00 Null pointer
10 Pointer to attribute element
20* Pointer to space element
30** Pointer to volume element
40** Pointer (from the indexed file's name element) to the name element of the information file
41** Pointer (from the information file's name element) to the name element of the indexed file
50 Pointer (from the lower paired file's name element) to the name element of the upper file
51 Pointer (from the upper paired file's name element) to the name element of the lower file
60* System pointer (from the pack catalog name element describing the pack catalog) to the
chain of available entry blocks within the pack catalog
61* System pointer (from the pack catalog name element describing the pack catalog) to the
chain of available continuation blocks within the pack catalog
70** System pointer (from the central catalog name element describing the central catalog) to
the chain of available entry blocks within the central catalog
71** System pointer (from the central catalog name element describing the central catalog) to
the chain of available continuation blocks within the centrai catalog
80** System pointer (from the name element of a SYSIN or subordinate scratch or temporary
file) to the name element of the next chronologically sequenced scratch or temporary file.
Scratch or temporary files are cataloged like any other file, in that they are entered by
collating sequence into the main chain of existing files. In addition, the scratch or temporary
file is linked in a secondary chain to the pertinent SYSIN entry through use of the forward
system pointer (identification of 80) and backward pointer (identification of 81).
81** System pointer (from the name element of a scratch or temporary file) to the name element
of previous scratch or temporary file or to the SYSIN entry at the front of the secondary
chain
39-41, Pointers {in BBR format) to the pertinent elements previously described.
43-45,
47-49
Table 2-2. Attribute Element [Format
000 General
001 Indexed
0
9 Standard Control Bytes
4| PF Pl WV FT FO CF CD CC Spread
6 Block Size
8 Record Length
10 Relative Key Position
12 : Key Size
14 Highest Block Written
16
18 Reserved
20
22
Modification Security Code
24
26 |
Offset
28
Byte Bit Description
0-3 Control bytes (defined in Table 2-1)
4 0 Paired file flag. If PF=1, file is paired
1 Paired index (P1)
0 Upper file
1 Lower file
2 Write verify (WV)
0 No write verify
1 Write verify
3,4 File type (FT)
|
| 00 Permanent
01 Scratch
10 Temporary
11 Work
5-7 File organization (FO)
2-6
Table 2-2. Attribute Element Format (continued)
Byte Bit Description
010 Relative
100 Sequential
111 Information (for indexed file)
5 1 Central catalog (CF)
0 File is uncataloged
1 File is cataloged
2 Comrnon stored data format (CD)
0 Not common stored data format
1 Common stored data format
3 Control character (CC)
о ANSI control characters
1 Native device control characters
4-7 Spread factor for indexed files (SPREAD)
6,7 Block size (in bytes) of data block
8,9 Record length {in bytes) of a record within a data block
10,11 Relative key position; pointer to the primary key in the data portion of a record. Position O refers to the first
byte following the control bytes.
12 Key size (in bytes) of the primary key
13-15 Highest block written, relative block number for the last block written in the file
16-21 Reserved
22-25 Modification security code
26-29 Offset; lower limit of relative record number at the time a relative file is created or, for a sequential file, the
relative block number for the first block of the highest volume written. In the information file's attribute
element for an indexed file, the first two bytes have the count of directory blocks that have been allocated.
The other two bytes have the count of index blocks.
2-7
12
14
16
18
20
22
24
Table 2-3. Space Element and Space Element Continuation Format
Standard Control Bytes
Continuation of Space Element
Segment Count
Segment Sequence Number
Track Address
Track Count
*One per segment
12
14
16
Space Element
Standard Control Bytes
Continuation of Space Element
Previous Space Element
Lv | ce | CB
Segment Sequence Number
Track Address
Track Count
tOne per segment
2-8
Space Element Continuation
Table 2-3. Space Element and Space Element Continuation Format (Continued)
Byte Bit Description
0-3 Control bytes (defined in Table 2-1)
4-6 Continuation of space element, a thread (in BBR format) which points to the next space element continuation
for a file
7-9* Previous space element is a thread (in BBR format) which points to the previous space element.
10 о If LV=1, this is the last volume for a file
1 If CE=1, a space element continuation exists
2 If CB=1, each segment lower boundary is on a cylinder boundary
11-17; Not used
11*
18,19 Segment count, a count of space elements used by the file on this volume
20,21; Segment sequence number, giving relative segment number for each segment (shows relation to segments
12,13* existing on same or separate volumes)
22,23; Track address relative to beginning of segment. (All physical disc addresses are expressed in terms of track
14,15* number rather than cylinder and track within a cylinder.)
24,25; Track count of tracks in segment
16,17*
*Byte position(s) unique to space element continuation table.
Table 2-4, Volume Element and Volume Element Continuation Format
0
„ Standard Control Bytes
4 Continuation of Volume Element
6 MD
8 Segment Count
10 Volume Count
12
14 Volume Serial Number
16
18 File Name Entry in Pack Catalog
20 Device Type
22 Reserved
*One per volume
Volume Element
Standard Controi Bytes
4 Continuation of Volume Element
6 мо | се |
8
10 Volume Serial Number
12
14 File Name Entry in Pack Catalog
16 Device Type
18 Reserved
tOne per volume
Volume Element Continuation
2-10
Table 2-4, Volume Element and Volume Element Continuation Format (Continued)
Byte Bit Description
0-3 Control bytes (defined in Table 2-1)
4-6 Continuation of volume element, a thread (in BBR format) which points to the next volume element continuation
for a file
7 0 Modified volume descriptions. If MD=1, central catalog is created and modified volume descriptions are
included,
1 If CE=1, volume element continuation exists
8,9 Segment count
10,11 Volume count
12-17; Volume serial number
8-13*
18-20; File entry in pack catalog, a pointer to the file's entry in the specified volume's pack catalog (BBR format)
14-16* |
21;17* Device type (00, 5 for MEMOREX 3664 Drive)
22;18* о If HW=1, highest volume written
23;19* Reserved
*Byte position(s) unique to volume element continuation table.
TABLES
Tables are primarily for storage information that is
easily referenced. The Data Management system has
two primary tables for information reference:
e File Description Table (FDT) created by
OPEN
e Buffer Description Table (BDT) created by
DEFSF, DEFRF, or DEFIF
FILE DESCRIPTION TABLE
A File Description Table (FDT) is built dynamically
during a job's execution time in the user area of
memory. An OPEN request causes an FDT to be
built, and a CLOSE request releases the FDT space.
The FDT is 60 bytes in length. The portion of the
FDT common to all files is 40 bytes in length, and
the remainder of the FDT which is device dependent
is 20 bytes in length.
The FDT is linked with block 1/0 requests through an
8-byte identification field; the identification field in
the FDT and the block 1/0 request must match. The
FDT contains a unit table ordinal through which 1/0
control routines find the unit table and execute the
I/O request. Parameters in the FDT protect users
from overlapping each other's area on a shared device.
Table 2-5 gives the locations of the different
information fields of the FDT. Tables 2-6 through 2-8
give the device-dependent fields of the FDT.
Manipulation of FDT's in the user partition is
discussed in Control Language Services, Extended
Reference.
2-12
BUFFER DESCRIPTION TABLE
A Buffer Description Table (BDT) is created by the
file definition macros (DEFSF, DEFRF, and DEFIF).
This main-memory table is used by the GET/PUT
logic to manage buffers and control logical records.
The BDT is responsible for recording location of 1/0
buffer(s) and record areas.
A BDT is created for each file organization:
sequential, relative, indexed. The three BDT format
tables follow with the appropriate field descriptions
(Tables 2-9 through 2-11).
Table 2-5. File Description Table Format
-10 Reserved
-8 LOA
4 Label Ordinal
-2 PFL
NFL
o
NC Device Type
Identification
US B UD L SF Last Block 1/0 Function
Current Block Number .
Return Code
Tag for CW
22 Block Size
24 Current CW Pointer
26 Status
28 RC
30 Device Dependent Fields*
eee TT me
*Refer to appropriate device table (Tables 2-6 through 2-8).
Byte Bit Description
-10,-9 Reserved
-8,-7 Length (in bytes) of FDT (LOA)
-6 0 Ordinal bit (OB)
| 0 Label ordinal points to central catalog
1 Label ordinal points to Control Language job file
-5,-4,-3 Label ordinal indicates the position of the label in the central catalog or the Control Language job file.
-2,-1 Previous FDT address (PFL)
2-13
Table 2-5. File Description Table Format (Continued)
Byte Bit Description
0,1 : Next FDT address (NFL)
2 1 User bit (UB) reserved for emulator set to zero when FDT is built
2 Freeze flag (FRE)
0 File is not frozen
1 File is reserved for a recycle of outstanding queue entry block (QEB)
7 Native character set flag (NC). if NC=1, first data byte is the command code.
3 0-7 Device type
4-11 File identification
12 1 Common stored data format bit (C)
0 Not common stored data format
1 Common stored data format
2,3 Usage flag (US)
00 Input
01 Update
10 Output
4 Bypass flag (B)
0 No bypass
1 Bypass, READ goes to EOF and WRITE is a NOP
5 Update flag (UD)
0 No update
1 Update
6 Lockout flag (L)
0 No lockout
1 Close with lock
7 Sequential file (SF)
0 Not sequential
1 Sequential
13 0-7 Last function processed in block 1/0
14-17 Block number after last function processed. If zero, current block number is unknown.
18 2 End condition bit {END) indicates the sensing of an end condition: EOF, EOA, or printer carriage channels
9 or 12.
19 Return code
2-14
Table 2-5. File Description Table Format (Continued)
Byte Bit Description
20 0 Error recovery processing flag (ERP)
0 Call error recovery when errors encountered
1 Do not call error recovery for errors
3 FDT restore (FR)
0 FDT not restored
1 FDT restored
4 Hold up flag (H)
о File not in recovery
1 File in error recovery and following requests are held up until recovery complete
5 Block 1/0 internal flag (BB); set by block 1/0 to indicate that a RESET macro has passed through the file.
Bit is reset by driver.
21 Tag for command word (CW) address pointer
22,23 Byte size lor maximum size) of each record
24,25 A pointer to the current or last CW executed by this file
26,27 Status of last 1/0 operation
28,29 Residual count (RC): the difference between bytes requested and bytes received
The device dependent portion of the FDT begins at byte 30.
2-15
Table 2-6. Disc Device Format
30] Res. PF PA WF DF Reserved Number of Residual Blocks
32
Highest Block Writter:
34
36
Relative Block Number
38
40 Blks/Track | Gap
42 Next Segment Link
44 UORD Reserved
46 Number of Contiguous Tracks
48 Beginning Track Number
*Extent
Byte Bit Description
30 0 Reserved
1 Paired file flag (PF)
0 Nat paired
1 Paired file
2 Paired file indicator (PA)
0 Upper portion of track used for this file
1 Lower portion of track used for this file
3 Write check flag (WF)
0 No write check
1 Write check of all writes
4 Disc driver flag (DF)
5-7 Reserved
31 Residual block number, the number of blocks remaining to be up for a multiblock read request which crosses
tracks
32-35 Highest block number written for volume now mounted
36-39 Relative block number (calculated from beginning of file) of first block on presently mounted volume
40 0-5. Number of records on a disc track (BLK/TRACK)
40,41 6-7, Gap in bytes between records for pack rotational speed variation
0-7
42-43 Next segment link {extent address)
2-16
Table 2-6. Disc Device Format (Continued)
Byte Bit Description
44 Unit table ordinal ({UORD) which indicates the unit table to which this segment is related
45 Reserved
46,47 Number of contiguous tracks
48,49 Beginning track number for this extent (0-3999)
2-17
Table 2-7, Magnetic Tape Device Format
30
32 Sense
34
36]
Relative Block Number
38
44
UORD ALT ORD
Byte Bit Description
30-35 Sense bytes of the unit at the time of the last error
36-39 Relative block number (calculated from beginning of file) of first block on presently mounted volume
44 Current unit table ordinal (UORD)
45 Unit ordinal of alternate tape (ALT ORD)
46 Volume number
47 0 Label processing flag (LP)
0 No label processing.complete
1 Label processing complete
1 Tape mark flag (TM); a tape mark precedes the first data record on the tape
7 Offset (0), an alternate unit
2-18
Table 2-8. Unit Record Device Format
Byte Bit Description
30 Sense byte of the unit at the time of last error
31 Unit table ordinal (UORD)
Table 2-9, Buffer Description Table Format for Sequential Files
0 GET/PUT Address
2| NB FTYP S LABL AM RT Blocking Factor
4 Block Size
6 Record Size
8 STAG GP MOD S TAG RA
10 Record Area Address |
12
File Identification
S TAG SA
22 Save Area Address
24 Error Offset
S TAG RAP
28 Record Address Pointer
30
Relative Record Number
32
34
Current Block Number
36
38 Logical Record Number
40| Ру | дв | г | UR Lo] у] ж| с] в
42
Work Area
44
46
Move Routine
54
2-20
Table 2-9. Buffer Description Table Format for Sequential Files (Continued)
56
J}
Ww
Block 1/0 Packet
23)
au
66
Ww
T Buffer 1 1/0 Packet я
88
90
L 1
T Buffer 2 1/0 Packet
S TAG EA
114 Error Address
*Optional
If buffer 2 is absent, bytes 90 through 93 end the BDT as follows:
STAG EA
92 | - Error Address
Byte Bit Description
0,1 External address of the GET/PUT module processing this file
2 0 Number of buffers (NB)
0 One buffer
1 Two buffers
1,2 File type (FTYP)
00 Sequential
01 Relative
10 Indexed
3 Shared buffer flag (S). If S=1, 1/0 buffers are shared with other files.
45 Label processing (LABL)
00 No labels
2-21
Table 2-9. Buffer Description Table Format for Sequential Files (Continued)
Byte Bit Description
01 Nonstandard labels
10 Standard labels
6 Access method (AM)
0 Sequential
1 Random
7 Record type (RT)
0 Fixed length
1 Variable length
3 Blocking factor, number of records per block (0-255)
4,5 Block size (in bytes) of the I/O buffer(s), size must include record headers
6,7 Record size (in bytes) of maximum record excluding header
8 Segment tag for GET/PUT module (S TAG GP MOD)
9 Segment tag for record area address (S TAG RA)
10,11 Record area address, first byte of record area
12-19 File identifier for data file (8 bytes EBCDIC)
21 Segment tag for save area address (S TAG SA)
22,23 Save area address, calling program’s linkage and register save area
24,25 Error offset, offset (in bytes) to error address from beginning of BDT
27 Segment tag for record address pointer (S TAG RAP)
28,29 Record address pointer, first byte address of active record in active 1/0 data buffer
30-33 Relative record number, record number relative to first record in the file
34-37 Current block number, physical block number present in active buffer
38-39 Logical record number, number of active record in active buffer
40 0 If PU=1, the record address pointer has been updated following a PUT or reset to the first record in the active
buffer.
1 Active buffer (AB)
0 First buffer
1 Second buffer
2 PUT flag (P). If P=1, record has been written in the active data buffer.
3 Unit record flag (UR). If UR=1, device is not disc or tape.
2-22
Table 2-9. Buffer Description Table Format for Sequential Files (Continued)
Byte Bit Description
5 Limits flag (L). If L=1, limits are defined for relative files
6 1/0 register flag (1)
0 Record area
1 1/O register
7 Verify flag (V). 15 V=1, write verify is performed.
41 0 Skip flag (SK). If SK=1, error option is to skip error.
1. Ignore flag (1G). 1f 1G=1, ignore option was selection.
2 Binary bit (B). 1f B=1, binary cards are to be read.
6,7 1/0 usage (USE)
00 Input
01 Update
10 Qutput
42-45 Work area
46-55 Move routine. Data movement routine consisting of a MOVL instruction followed by a BR instruction.
56-67 Block 1/0 packet used to issue service requests such as CLOVE, POSITION, and RESET.
68-69 Buffer 1/0 packet for 1/0 between the data file and the first 1/0 buffer.
90-111* Buffer 2 1/0 packet for 1/0 between the data file and the second 1/0 buffer. (Optional)
113*,91t Segment tag for error address (S TAG EA)
114-115*; Error address, address of error return
92-937
*Byte positions unique to BDT for seguential files when buffer 2 is present.
+Byte positions unique to BDT for sequential file when buffer 2 is absent.
2-23
Table 2.10. Buffer Description Table Format for Relative Files
0 GET/PUT Address
NB FTYP S | LABL | AM | RT | Blocking Factor
4 Block Size
6 Record Size
8 S TAG GP MOD | STAG RA
10 Record Area Address
12 |
File Identification
S TAG SA
22 Save Area Address
S TAG RAP
28 Record Address Pointer
30
Relative Record Number
32
34
Current Block Number
36
38 Logical Record Number
40 Ро | дв | в | ов] L| ov] sx IG | в
42
Work Area
44
46
T Move Routine о
54
56
7 Block 1/0 Packet ~
66
68
Tr Buffer 1 1/0 Packet T
88
2-24
Table 2-10. Buffer Description Table Format for Relative Files (Continued)
90
Buffer 2 1/0 Packet
32
u
S TAG AK
114 Key Address Pointer
116
Limit X
118
120
Limit Y
122
124
Offset
126
128 S TAG EA
130 a. Error Address
*Optional
if buffer 2 is absent, bytes 90 through 109 end the BDT as follows:
S TAG AK
92 Key Address Pointer
94
Limit X
96
98
Limit Y
100
102
Offset
104
106 S TAG EA
108 Error Address
*Optional
2-25
Table 2-10. Buffer Description Table Format for Relative Files (Continued)
Byte Bit Description
0,1 External address of the GET/PUT module processing this file
2 0 Number of buffers (NB)
0 One buffer
1 Two buffers
1,2 File Type (FTYP)
00 Sequential
01 Relative
10 Indexed
3 Shared buffer flag (S). If S=1, 1/0 buffers are shared with other files.
4,5 Label processing (LABL)
00 No labels
01 Nonstandard labels
10 Standard labels
6 Access Methad (AM)
0 Sequential
1 Random
7 Record type (RT)
0 Fixed length
1 Variable length
3 Blocking factor, number of records per block (0-255)
4,5 Block size (in bytes) of the 1/0 buffers, size must include record headers
6,7 Record size (in bytes) of maximum record excluding header
8 Segment tag for GET/PUT module (S TAG GP MOD)
9 Segment tag for record area address (S TAG RA)
10,11 Record area address, first byte of record area
12-19 File identifier for data file (8 bytes EBCDIC)
21 Segment tag for save area address (S TAG SA)
22,23 Save area address, calling programs linkage and register save area
24,25 Error offset, offset (in bytes) to error address from beginning of BDT
27 Segment tag for record address pointer (S TAG RAP)
28,29 Record address pointer, first byte address of active record in active 1/0 data buffer
30-33 Relative record number, record number relative to the first record in the file
2-26
Table 2-10. Buffer Description Table Format for Relative Files (Continued)
Bit
Byte Description
34-37 Current block number, physical block number present in active buffer
38-39 Logical record number, number of active record in active buffer
40 0 If PU=1, the record address pointer has been updated following a PUT or reset to the first record in the active
buffer.
1 Active buffer (AB)
о First buffer
1 Second buffer
2 PUT flag (P). If P=1, record has been written in the active data buffer.
3 Unit record flag (UR). If UR=1, device is not disc or tape.
—D Limits flag (L). If L=1, limits are defined for relative files.
6 1/0 register flag (1)
0 Record area
1 1/O register
7 Verify flag (V). If V=1, write verify is performed.
41 0 Skip flag (SK). If SK=1, error option is to skip error.
1 Ignore flag (1G). If 1G=1, ignore option was selected.
2 Binary bit (B). If B=1, binary cards are to be read.
6,7 I/O Usage (USE)
00 Input
01 Update
10 Output
42-45 Work Area
46-55 Move routine. Data movement routine consisting of a MOVL instruction followed by a BR instruction.
56-67 Block 1/0 packet used to issue service requests such as CLOVE, POSITION, and ADD KEY/DELETE KEYS.
68-89 Buffer 1 1/0 packet for 1/0 between the data file and the first 1/O buffer.
90-111* Buffer 2 1/0 packet for 1/0 between the data file and the second 1/0 buffer.
113*,91t Segment tag for key address pointer (S TAG AK)
114,115*; Key acldress pointer. First byte address of key address field for relative file.
92,931
2-27
Table 2-10. Buffer Description Table Format for Relative Files (Continued)
Byte Bit Description
116-119*; Limit X, lower limit for processing. Optional.
94-971
120-123*; Limit Y, upper limit for processing. Optional.
98-101 t
124-127*; Offset, lower limits defined when file was first created. Optional.
102-105t
129*;107t Segment tag for Error Address (S TAG EA)
130,131*; Error address. Address of error return.
108,109t
*Byte positions unique to BDT for relative files when buffer 2 is present.
tByte positions unique to BDT for relative files when buffer 2 is absent.
2-28
Table 2-11. Buffer Description Table Format for indexed Files
0 GET/PUT Address
2 | NB FTYP S LABL AM RT Blocking Factor
4 Block Size
6 Record Size
8 S TAG GP MOD S TAG RA
10 Record Area Address
12
File Identification
18
20 К. S TAG SA
22 Save Area Address
24 Error Offset
26 Ko S TAG RAP
28 Relative Address Pointer
30
Relative Record Number
32
34
Current Block Number 1
36
38 Logical Record Number
40 PU | AB | Р | о | 5 | F | || V
42
Work Area
44
46)
T Move Routine 1
54
56
a Block 1/0 Packet A
66
68
T Buffer 1 1/0 Packet A
88
2-29
Table 2-11. Buffer Description Table Format for Indexed Files (Continued)
Ww
Lu
90
T Index Buffer 1/0 Packet T
110
112 K3 | S TAG AK
114] KEYADR1 Address Pointer
116 C1 | Co
118 Index Buffer Block |
120 -
Current Index Block
122
124] Key Size S TAG IKP
126 Index Block Key Address Pointer
128 Directory to the Directory Block Address
130 Number of Directory Blocks
132
Physical Block Number
134
136
25 Compare Routine A
144
146 5 TAG FK
148 | KEYADR2 Address Pointer
150
Buffer 2 1/0 Packet 7
170
172
Current Block Number 2
174 |
176 f sn e ve STAG HLDB
178 Directory to the Directory Block Pointer |
180 S TAG EA
182 Error Address
*Optional
If buffer 2 is absent, bytes 150 through 157 end the BDT as shown:
2-30
Table 2-11. Buffer Description Table Format for Indexed Files (Continued)
150 о S TAG HLDB
152 Directory to the Directory Block Pointer
14 О S TAG EA
156 Error Address
*Optional
Byte
Bit Description
01
External address of the GET/PUT module processing this file
0 Number of buffers (NB)
0 One buffer
1 Two buffers
1,2 File type (FTYP)
00 Sequential
01 Relative
10 Indexed
3 Shared buffer flag (S). 1f S=1, 1/0 buffers are shared with other files.
4,5 Label processing (LABL)
00 No labels
01 Nonstandard labels
10 Standard labels
6 Access method (AM)
0 Sequential
1 Random
7 Record type (RT)
О Fixed length
1 Variabie length
Blocking factor, number of records per block (0-255)
4,5
Block size (in bytes) of the 1/0 buffer(s), size must include record headers
6,7
Record size (in bytes) of maximum record excluding header
Segment tag for GET/PUT module (S TAG GP MOD)
Segment tag for record area address (S TAG RA)
10,11
Record area address, first byte of record area
12-19
— File identifier for data file and information file (8 bytes, EBCDIC)
2-31
Table 2-11. Buffer Description Table Format for Indexed File (Continued)
Byte Bit Description
| — фе. ——] ae
20 Spread factor (K4), indicating how many passes made on each track
21 Segment tag for save area address (5 TAG SA)
22,23 Save area address, calling program's linkage and register save area
24,25 Error offset, offset (in bytes! to error address from beginning of BDT
26 Number of blocks per track minus one (K2)
27 Segment tag for record address pointer (S TAG RAP)
28,29 Record address pointer, first byte address of active record in active 1/0 data buffer
30-33 Relative record number, record number relative to the first record in the file
34-37 Current block number 1, physical block number present in data buffer 1
40 0 If PU=1, the index biock key address pointer was updated by a DELR, PUT, or PUTU instruction in sequential
access mode.
1 Active buffer (AB)
0 First buffer
1 Second buffer
2 PUT flag (P). If P=1, record has been written in the active data buffer
3 End-of-file flag (EOF). If EOF=1, the end-of-file has been reached.
4 Index sharing flag (15). 1f 1S=1, index buffer is shared with data buffer.
5 Index file flag (IF). If 1F=1, index block was just read or written.
6 1/0 register flag (I)
0 Record area
1 1/0 register
7 Verify flag (V). If V=1, write verify is performed.
41 1 Ignore flag (1G). If 1IG=1, ignore option was selected.
3 Previous GET flag (PG). If PG=1, last operation was a GET.
4 Index write flag (IW}. if IW=1, KEY is added or deleted in current index block.
6,7 1/0 usage (USE)
00 Input
01 Update
10 Output
42-45 Work Area
46-55 Move routine. Data movement routine consisting of a MOVL followed by a BR instruction.
2-32
Table 2-11. Buffer Description Table Format for Indexed Files (Continued)
Byte Bit | Description
56-67 Block 1/0 packet, used to issue service requests such as CLOV E, POSITION, and ADD KEY/DELETE KEYS.
68-89 Buffer 1 1/0 packet for 1/0 between the data file and the first 1/0 puffer. e
90-111 Index buffer 1/0 packet. 1/0 parameter packet for 1/0 between the information file and the index buffer.
112 Number of blocks per pass minus one (K3).
113 Segment tag for key address 1 pointer (S TAG AK)
114,115 Key address 1 (KEY ADR1) pointer, first byte address of key address 1 field
116 Current pass boundary counter (C4)
117 Current track boundary counter (Сэ)
118,119 index buffer size, in bytes
120-123 Current index block number: physical block number present in index buffer.
124 Key size, size (in bytes) of primary key field
126 | Segment tag for index block key address pointer (S TAG IKP)
126,127 Index block key address pointer, first byte address of active key in index buffer
128,129 Block address of directory to the directory block
130,131 Number of directory blocks written
132-135 Physical block number of data block to be read or written
136-145 “Compare routine, data comparison consisting of a CMP X instruction followed by a BR instruction.
146 0 KEYADR2 flag (F)
0 KEY ADR?2 not present
1 KEYADR2 present
1 Directory to the directory block flag (D)
0 Directory to the directory block in mass storage
1 Directory to the directory block in main storage
147* Segment tag for key address 2 (KEY ADR2) pointer (S TAG FK)
148,149* Key address 2 (KEY ADR2) pointer
150-171* Buffer 2 1/0 packet, parameter packet for 1/0 between data file and second 1/0 buffer
172-175* Current block number 2, physical block number present in data buffer 2
177* 151+ Segment tag for directory to the directory block pointer (S TAG HL.DB)
178,179*; Directory to the directory block pointer, first byte address of main storage directory to the directory block
152,153t
2-33
Table 2-11. Buffer Description Table Format for Indexed Files (Continued)
Byte Bit Description
181*;155t Segment tag for Error Address (S TAG EA)
182,183*; Error address, address of error return
156,157t
*Byte positions unique to BDT for indexed files when buffer 2 is present.
iByte positions unique to BDT for indexed files when buffer 2 is absent.
2-34
INTRODUCTION
The block level of input/output processing may be
‘applied either to files which were previously
processed at the logical level* or to files intended for
use at the block level only. But whatever the
organization of the file being processed, the data is
referenced by key block number or as next data
block for the unit record devices.
The basic unit of data transfer at the block (and
physical) level is the block. Thus the
block-input/output user may only read or write a
whole block of data at a time (not individual records
within a block).
If the user is operating on files created specifically for
block input/output use, he is free to establish within
the blocks any arrangement or grouping of logical
records he wishes, and the blocking and deblocking of
these records must of course be performed by the
user himself. However, it should be noted that if he
wishes to operate on previously-created files which
were used for logical input/output, he must be aware
of the pre-established logical structure of the data
within the blocks.
*Sequential and relative files may easily be processed by
block input/output but it is not practical to apply block
input/output to indexed files.
3. BLOCK INPUT/OUTPUT
GENERAL RULES
Tape and disc files for block input/output processing
are created in the same way as those created for
logical input/output (that is, through Control
Language //DEF statements external to the program
or ALLOC macros internally). These are standard
system file structures and the following rules of file
logic must be observed when processing them:
e A file must be opened before it may be
processed
e All blocks within a given disc file must be of
the same length
e Blocks must be at least two bytes long for
disc requests (printer and card punch
requests are two bytes long).
e Block numbers may go from 1 to 232-1 (disc
block is 224-1)
e All buffers must begin on word boundaries
for disc |
e Read buffers will terminate on word
boundaries for disc
In addition, the following restrictions should be
noted:
e Processing across volume boundaries on
sequential files is not allowed without calling
CLOVE
e Multi-block reading will only be
implemented for files with blocks of an even
byte length
e Key fields are not supported for disc storage -
and will be ignored if present
3-1
BLOCK INPUT/OUTPUT CODING
A set of system macro instructions is provided for
block input/output coding. The basic macros are
READ, WRITE, POSITN and CNTRL. With these
instructions blocks of data may be read and written,
files may be positioned to particular blocks in
preparation for processing, and certain hardware
commands not involving data transfer may be
performed. Other facilities that might be required are
provided by the STATUS macro, which allows file
status checking; the TYPE macro, which returns
device type; and the RESET macro, which enables
error conditions to be cleared (to allow for
continuation after an error).
A particular block of data within a file is referred to
by number. All files are ordered sequentially, with
the first block of the file being block number 1. As an
aid to processing files in a sequential manner, explicit
block numbers are not necessary. Any data request
with an implied block number causes the block
number to be updated. The block referred to by a
request is determined relative to an internal block
number maintained by the 1/0 control routines.
BLOCK READING
The READ macro reads a block of data from a
specified file and stores it at a specified buffer
address. The number of the block to be read is
obtained either directly from the READ call (if
specified) or by adding 1 to the current block count
saved by the system. After the READ is executed the
updated block number will replace the old block
number in the file's block counter so that a
subsequent READ will automatically read the next
block.
If a POSITN macro (to the same file) is executed
immediately preceding a READ, the current block
number will be used without change. When a file is
opened for input (reading) its block counter is
initially set at 1.
BLOCK WRITING
The WRITE macro transfers a block of data from a
specified buffer address to a specified file. The
number of the block into which the data is to be
written is obtained either directly from the WRITE
call (if specified) or by adding 1 to the current block
Table 3-1. Assumed Block Numbers
Operational Sequence Effect
READ Disc: Each Read causes a one-count increase in the block number
before the operation.
READ
All: Records are read sequentially.
READ
WRITE Disc: Each Write causes a one-count increase in the block number
after the operation.
WRITE
All: Records are written sequentially.
WRITE
POSITN POSITN The block referred to by Positn is used for the Read or Write request.
or
READ WRITE
READ Disc: The block written replaces the block just read.
WRITE Reader/Punch: The block is written into the card just read (file open for update);
and the block is written into the next card (file open for output).
Mag Tape The block is written after the block just read.
WRITE Disc: The block number is increased after the WRITE operation and
not prior to the Read operation. This avoids skipping the next
READ sequential block.
Reader/Punch: Card n is written. Card n+1 is then read.
Mag Tape: Invalid sequence.
3-2
count saved by the system. After the WRITE is
executed the updated block number will replace the
old block number in the file's block counter so that a
subsequent WRITE will automatically write into the
next block.
If a POSITN macro (to the same file) is executed
immediately preceding the WRITE the current block
number will be used without change.
If a READ macro immediately precedes a WRITE,
the current block number will be increased by 1 in
the normal way for a magnetic tape file but will not
be altered in the case of a disc file.
When a file is opened for output (writing), what
happens to the block counter depends on the type of
file. For scratch, temporary and work files, opening
the file sets the block counter to 1. For permanent
files, however, the block counter will not be altered
and will retain the value left in it on the previous use.
This enables data already contained on the file to be
saved between different job runs by adding new data
only to the end of the file (unless otherwise
specified).
Table 3-1 gives the assumed block numbers for the
READ, WRITE, and POSITN macros.
BLOCK POSITIONING
The current block number of a file may be preset by
a POSITN macro for subsequent reading or writing.
This macro sets the current block counter of a
specified file to a specified value.
DEVICE CONTROL COMMANDS
Input/output device control commands, not involving
a data transfer, may be implemented by the CNTRL
macro. This macro transmits a specified command to
the device containing a specified file. Typical
commands transmitted by this macro are Skip to Top
of Form for line printer, Rewind Tape for tape drive.
SPACE MANAGEMENT AND FILE CONTROL
Space management and file control for block
input/output are handled by Data Management
functions described in Section 2. For space
management ALLOC, EXPAND and PURGE are
used. For file control OPEN, CLOSE and CLOVE are
used.
PROCESSING CONSIDERATIONS
REQUEST OVERLAP
Multiple requests to the same file or the same device
can be issued. However, to avoid ambiguous results,
separate request blocks and data buffers must be
used. Requests will be honored in the order of receipt
within a file. Issuing multiple reguests, with the aid of
the RETURN=YES operand in the requesting macros,
improves throughput by enabling the system to
overlap input/output set-up time with data
transmission.
PRIORITY
Input/output requests are processed by the system
according to the priority of the program which issues
them. This priority is specified in the Control
Language //JOB card and is set at the time the job is
initiated. ;
END CONDITIONS
End conditions are special boundary conditions
resulting in return indications to the user but not
considered as errors.
e End of File (EOF)
EOF is a logical boundary defined for input
files. Each device™ capable of reading has a
defined end of file condition. EOF provides
a condition in the data stream which is
uniquely detectable by the system. After
EOF has been detected on disc, magnetic
tape, or the card reader, a RESET macro
must be issued before processing may
continue.
On the card readert, a data record beginning
with the characters /* is defined to be an
end-of-file condition. When EOF is detected,
the entire record will be transferred to the
user's buffer.
On magnetic tape the EOF condition is set
whenever a tapemark is detected.
* An exception to this is the card reader where the /* card is
used to indicate the EOR condition in the EBCDIC mode.
In the EBCDIC=NO mode, there is no EOF condition
detectable by an 1/O driver because all data images are
considered to be legal data.
tT The operator-selected EOF option on IBM card readers is
not supported.
With disc, the EOF condition is set when a
block with a data-length specification of
zero has been read. Note that an embedded
EOF will not be detected, however, during a
multi-block read.
e Endof Allocation (EOA)
EOA is a physical boundary applying only to
disc output files. An EOA indication is
returned any time a block is written into the
last allocated space for the file.
e End of Tape (EOT)
EOT is a physical boundary applying only to
magnetic tape output files. It signifies that
the end-of-tape reflective marker has been
sensed.
PROCESSING MULTI-VOLUME FILES
When processing sequential files occupying more than
one physical volume (disc and tape only), the block
input/output user must perform volume switching to
move from one volume to another.
At any given time, the File Description Table for a
sequential file* may only describe a single physical
volume, which limits the current range of processing
to the described volume. When, during processing, the
user encounters an EOV indication or wishes to
prematurely close the volume and switch to the next
volume he must issue a CLOVE (close volume) macro
to continue processing on the next consecutive
volume. CLOVE ensures that the next volume is
mounted, by issuing an operator message if necessary,
and then modifies the FDT to describe the next
volume.
If there are no more volumes to be processed, the
EOF/EOA bit (bit 2 of the return information) in the
CLOVE packet is set. The user is responsible for
testing this condition.
SENSE INFORMATION
The number of bytes of sense information varies with
the device. All the bytes for the device are maintained
in the File Description Table, and are updated
whenever an abnormal completion occurs for reasons
*An FDT for a relative file describes the whole file, therefore
eliminating the need for CLOVE in this case.
3-4
other than logical errors. A STATUS macro request
transfers this information from the File Description
Table to the user buffer (to the extent that user
buffer allows).
REQUEST TERMINATION
The user requesting a block 1/0 operation has two
options while a request is processed:
e to wait for the request to be completed.
e to return to do parallel processing after the
request is recognized and before the request
is processed to completion.
If the user elects to wait for the request to be
completed before continuing with processing, his
program will be suspended by the operating system
until the request has been terminated.
If the user has returned to do parallel processing, the
COMPLETE indicator in the parameter string is set
when the request is returned from the 1/0 control
routines.
ERROR PROCESSING
At the block input/output level, the system
automatically provides attempted recovery from
hardware device errors. If peripheral device error
recovery is successful, control is returned to the user
with no error indication.
In the case of an error return (where peripheral device
error recovery has been unable to correct the error),
the program (and the rest of the job) normally is
aborted. However, if ERRCOMP=Y ES is coded in the
request macro, control is returned to the user
together with return information (Appendix C) thus
enabling him to process the error condition himself.
It should be noted that before issuing another request
to the same file following an error return, the user
may first have to reset the error condition with a
RESET macro (Appendix C).
Examples of block input/output are shown in Figures
3-1 and 3-2.
START )
OPEN
FILES
«VES
CLOSE
FILES
r
END
LABEL OPER'N OPERANDS COMMENTS
OPEN IDENT=CARDIN,IOTYP=B,USAGE=I OPEN CARD INPUT FILE
OPEN IDENT=PRINT IOTYP=B,USAGE=0 OPEN PRINTER OUTPUT FILE
START READ IDENT=CARDIN,DATABUF=CRDIMG READ A CARD
TBIT 2, START+4 CHECK FOR END-OF-FILE IN REQ BLOCK
BOV END IF EOF, GO CLOSE FILES AND END PROGRAM
WRITE IDENT=PRINT,DATABUF=CRDBUF PRINT CONTENT OF A CARD
B START GO READ ANOTHER CARD
END CLOSE IDENT=CARDIN,IOTYP=B CLOSE CARD FILE
CLOSE IDENT=PRINT I0TYP=B CLOSE PRINTER FILE
HALT TERMINATE PROGRAM
oR OR KR x ok kX wk * * * * * DATA AREA * * * * *!х + A % AAA AAA
CRDBUF WRS 80 CARD/PRINT BUFFER
CARDIN WDD C'CARDIN * CARD FILE IDENT
PRINT WDD CPRINT * PRINTER FILE IDENT
Figure 3-1. Block 1/0 Program to Read Cards and Print
3-5
( START )
Ч
OPEN
FILES (DISC FILE
OPENED FOR OUTPUT)
E.
-
q
RESET
DISC BUFFER
INDEX
— MOVE CARD
IMAGE TO
DISC BUFFER
(INDEXED)
EOF
NO
YES
Y
CLOSE DISC FILE
& REOPEN IT
FOR INPUT
Зы,
Y
READ A BLOCK
FROM DISC
YES
EOF
NO
RESET
DISC BUFFER
INDEX
INCREASE COUNT,
DISC BUFFER
INDEX
WRITE
BUFFER
TO DISC
(ONE BLOCK)
|.
”
MOVE ONE
CARD IMAGE
FROM DISC BUFFER
TO PRINT LINE
(INDEXED)
A
PRINT
CARD IMAGE
y
INCREASE COUNT,
DISC BUFFER
INDEX
DISC
BUFFER
EMPTY
NO
Figure 3-2. Block 1/0 Program to Read Cards into Disc File
CLOSE
FILES
END
LABEL OPER'N OPERANDS COMMENTS
OPEN IDENT=CFIL,IOTYP=B,USAGE=I OPEN CARD FILE
OPEN IDENT=DFIL,IOTYP=B,USAGE=0 OPEN DISC FILE FOR QUTPUT
OPEN IDENT=PFIL,IOTYP=B,USAGE=0 OPEN PRINTER FILE
START LODI 3,0 ZERO DISC BUFFER INDEX
CARDRD READ IDENT=CFIL,BUFADR=CBUF READ À CARD
MOVX DBUF(80, 3) CBUF (80) MOVE CARD IMAGE TO DISC BUFFER
TBIT 2 CARDRD+4 CHECK FOR END-OF-FILE
BOV RESET IF EOF, GO READ DISC FILE
ADDD 3,80 INCREMENT BUFFER INDEX
CMPD 3,800 CHECK IF BUFFER FULL
BNE CARDRD IF NOT, GO READ ANOTHER CARD
DISCWR WRITE IDENT=DFIL , BUFADR=DBUF,RETURN=YES | WRITE 10-CARD BUFFER ON DISC FILE
B START GO READ ANOTHER 10 CARDS
RESET CLOSE IDENT=DFILIOTYP=B CLOSE DISC FILE
OPEN IDENT=DFIL,IOTYP=B,USAGE=i REOPEN DISC FILE FOR INPUT
DISCRD READ IDENT=DFIL,BUFADR=DBUF READ A BLOCK FROM DISC
TBIT 2,DISCRD+4 CHECK FOR END-OF-FILE
BOV END IF EOF, GO END PROGRAM
LOD! 3,0 ZERO DISC BUFFER INDEX
MOVX PBUF(80),DBUF(80, 3) MOVE CARD IMAGE FROM DISC BUFFER TO PRINT
LINE
PRINT WRITE IDENT=PFIL,BUFADR=PBUF PRINT A CARD IMAGE
ADDD 3,80 INCREMENT DISC BUFFER INDEX
CMPD 3,800 CHECK IF BUFFER HAS BEEN EMPTIED
BNE PRINT IF NOT, GO PRINT ANOTHER CARD IMAGE
B DISCARD GO READ ANOTHER BLOCK FROM DISC FILE
END CLOSE IDENT=CFIL,IOTYP=B CLOSE CARD FILE
CLOSE IDENT=DFIL,IOTYP=B CLOSE DISC FILE
CLOSE IDENT=PFILIOTYP=8 CLOSE PRINTER FILE
HALT TERMINATE PROGRAM
* + * + 1% * #* #* # # + *#* * E * * DATA AREA * * * * * *|* *
CBUF WRS 80 CARD BUFFER
DBUF WRS 800 DISC BUFFER
PBUF WRS 80 PRINT LINE
CFIL WDD C'CFIL ' CARD FILE IDENT
PFIL WDD C'PFIL ' PRINTER FILE IDENT
DFIL WDD C'DFIL ' DISC FILE IDENT
Figure 3-2. Block 1/0 Program to Read Cards into Disc File (Continued)
4. PHYSICAL INPUT/OUTPUT
INTRODUCTION
The physical 1/0 interface gives the user ability to
utilize the device drivers to perform
hardware-dependent 1/0 operations.
Physical input/output is independent of the system's
file processing scheme. Whereas block input/output
deals with files, physical input/output deals directly
with hardware devices. Use of physical I/O assumes
the following: |
e Devices to be used must be defined by
Control Language //DEF statements
e Devices must be opened for data
transmission (by the OPEN macro)
e Error recovery will automatically be
provided by the system (but may be
by passed if desired)
PHYSICAL INPUT/OUTPUT CODING
DEFINING AND OPENING DEVICES
Each device to be used for a physical input/output
operation must first be assigned by the system. This is
done through a System Control Language //DEF
statement. An OPEN macro must also be coded in the
user program to return the assigned unit ordinal used
in building the PCB (next paragraph).
PERFORMING THE PHYSICAL 1/0 OPERATION
To perform a physical 1/0 operation, three entities
must be created in the user's program:
e acommand program
e a physical command block (PCB)
e a'“do 1/0” instruction (EXCP)
The command program does not consist of directly
executable codes but is a chain of “command words”
which will be operated on by the system’s 1/0
processing routines. The program should be located in
a data area of the program and may be built by means
of COMMAND macros.
Examples of command word functions are these:
e print a record on a line printer
e select a stacker on a card reader
e seek on a disc file
read a card record from a card reader
For every physical input/output operation a Physical
Control Block (PCB) is required. The PCB should be
located in a data area. The Physical Control Block
may be build by a PCB macro.
To initiate the execution of physical 1/0 command
programs a single action macro, EXCP, is required: it
must be coded in line with the program’s executable
code. While the above general requirements are fixed,
there are several variations in the detailed
implementation, some of which allow more efficient
use of memory space than others. Efficient use of
device may be another consideration for not doing
this. First the basic method will be explained, and
then the more efficient methods will be described.
Basic Method
In the simplest situation, there is one PCB for each
command program and one EXCP for each PCB
(Figure 4-1). In this case, the address of the command
program may be assembled into the PCB by the
CPADR operand in the PCB macro, and the address
of the PCB may be assembled (by means of the PCB
operand) into the corresponding EXCP macro.
Sharing a PCB
When there are several command programs applying
to the same device, coding efficiency may be
improved by having these command programs all
share the same PCB (Figure 4-2). In this case the
address of the appropriate command program must
be dynamically supplied to the PCB before each
operation. This may be done by supplying the
appropriate command program address through the
related EXCP (by means of the CP operand) rather
than by presetting it into the PCB. Thus a group of
EXCP's may all specify the same PCB but different
command programs. Input/output operations to
different devices may be overlapped by coding
RETURN=YES in the appropriate EXCP instruction.
4-1
EXCP | EXCP EXCP
4
i
U
PCB : PCB PCB
al
ma
m
CP p
Figure 4-1. Basic Method for Physical 1/0
EXCP EXCP EXCP
J
De:
J 6
PCB
cp | CP | CP
Figure 4-2. Sharing a PCB
EXCP
PCB | PCB
CP CP CP CP CP
Figure 4-3. Sharing an EXCP
4-2
Sharing an EXCP
Sometimes it is possible to employ a single EXCP to
operate through a PCB on several command programs
or even to operate on several PCB's (Figure 4-3).
When this is to be done, the user may set up a table
of command program addresses (and PCB addresses,
if there are multiple PCB's). The EXCP will then refer
to the address tables at execution time by indirect
addressing with the CPADR operand and PCBADR
operand.
OVERLAPPED OPERATION*
There is a PCB for each input/output device;
input/output operations to different devices may be
overlapped by coding RETURN=YES in the relevant
EXCP instruction(s). This causes control to be
retained by the requesting program (while the 1/0
operation itself is concurrently being processed by
the system), thus enabling initiation of another 1/0
operation before the first has been completed.
Beyond this, it is also possible to overlap requests to
the same device, but it should be remembered that a
separate PCB and data buffer will be required for
each such overlapped request. When multiple requests
are issued in this manner, throughput will be
improved since the system is able to overlap 1/0
set-up time with data transmission. (The system will
always service multiple requests to the same device in
order of receipt.)
PHYSICAL REQUEST TERMINATION
When a physical 1/0 request is completed, several
values are returned to the calling program in the
* The effectiveness of overlapped coding is dependent on
the number of Queue Entry Blocks available in the
system, a SYSGEN variable.
command block (PCB):
e address of the last command word executed
or attempted to be executed
e hardware status indication
e residual byte count of last data operation
PHYSICAL 1/0 RESTRICTIONS
e Byte count must be less than 216-1 (65K)
e Multi-record read operations must not
attempt access to records across track
boundaries (disc).
e The user is responsible for validating a “read
count field" request (disc).
ERROR PROCESSING
System error recovery (Appendix C) is provided by
default just as it is at the block level. However, at the
physical level, system error recovery may be bypassed
by coding ERROPT=NO in the PCB macro. In any
case, an uncorrected error will always cause the
program to be aborted unless the operand
ERRCOMP=YES is coded in the EXCP macro making
the request. When ERRCOMP=YES is used, control is
returned to the user in the event of an error, together
with return information in the PCB so the user may
either ignore it or process the error himself.
EXAMPLE OF PHYSICAL 1/0 PROGRAM
Figure 4-4 shows a block diagram of a program to
read cards and print. A coding form illustrates the
code necessary for this physical 1/0 program.
4-4
( START )
OPEN
FILES
READ
A CARD
CLOSE
FILES
PRINT
EBCDIC END
CONTENT
OF CARD
Figure 4-4. Physical 1/0 Program to Read Cards and Print
Sv
(penunuo9) 11d pue spaeg peey 0) wesBo1d O/) ¡BISÁUd *b-$ eanBIJ
MEMOREX Assembler Coding Form Punching Instructions Date Poot
NAME OPERATION
12 34 5 6 7 81910 11 12 13 14 15 161
1234567 9{10 11 121314 15 16
Graphie | | | | | | Programmer
Punch | | | I I 1 progam
OPERAND IDENTIFICATION
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 7071 72/73 74 75 76 77 78 79 80
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 51 62 63 64 65 66 67 68 69 70 71 73 74 75 76 77 78 79
5. CONTROL PROGRAM SERVICES
INTRODUCTION
The executive services are those implemented directly
by the Control Program itself to assist the user in
various areas, such as input/output request control
and communication between job steps.
SERVICE REQUEST CONTROL
Control over the issuance of service requests by the
user program may be aided by the WAIT, INFORM
and DELAY™ macros. In one way or another, all of
these macros can detect completion of the user’s
service requests.
WAIT simply suspends program execution until
completion of the specified request or requests.
WAIT is used to wait for any one or all of the
outstanding service requests.
DELAY enables the user to suspend execution for a
specific period of time with the option of breaking
the delay (resuming execution} on the completion of
any service request.
INFORM offers the capability of detecting the
completion of a service request in the interval
between the issuances of the INFORM and its actual
processing by the system. This capability, which is
not available with the WAIT macros, is implemented
with the aid of a user-supplied count of the number
of outstanding requests he has at the time of issuing
the INFORM. By comparing this count with its own
count of outstanding requests, the system can
determine whether any requests had been completed
in the time since INFORM was issued by the user. In
addition to this, INFORM always returns control
immediately to the user fit has an implied
RETURN=YES operand) so that he may continue
processing and subsequently check completion of the
INFORM by testing the complete bit in the request
block,
INTER STEP AND CONTROL LANGUAGE
COMMUNICATION
User programs running as separate job steps in a
multi-step job have two ways of transferring data to
one another: The POST/RPOST pair of macros? and
the SETCOM/GETCOM pair of macros.
In addition, any program may influence the
subsequent course of the job by means of the SETIF
macro which posts information to be tested by an
//1F statement between later job steps.
The POST/RPOST pair of macros post and read a
single byte of data in the Job Control Table, whereas
the SETCOM/GETCOM pair post and read a full eight
bytes.
FINDING PARTITION SIZE
When a program is being written which is expected to
run in partitions of various sizes, it would often be
advantageous to code the program in such a way as to
occupy as much of the partition as is currently
available.
To achieve this fiexibility, a dynamic determination
of current partition size is necessary; this is provided
by the MEMLIM macro.
MEMLIM informs the program of the size of the user
portion of the partition in which it is currently
running by returning the starting address of the last .
addressable 256-byte page, expressed as an absolute
address. In effect, MEMLIM returns the starting
address of the last usable page below the partition
space pool. For this reason, programs which make use
of MEMLIM should always specify a fixed-length
space pool through the appropriate Link Editor
directive, since otherwise the space pool will
automatically commence on the page boundary
following the space allocated to the program.
*DELAY is not available on the minimal system.
+POST/RPOST conform to the IBM UPSI bit scheme.
READING DATA FROM //PAR CARDS
Data may be read from //PAR cards supplied in the
job control deck by means of the ACCEPT macro.
This macro transfers the contents of a single //PAR
card into a specified buffer. On the first execution of
ACCEPT, the first //PAR card is read; successive
executions automatically read the rest of the //PAR
cards consecutively. After the last //PAR card has
been read the next execution of an ACCEPT transfers
program control to a specified “end” address.
The user may also specify a particular //PAR card by
using the PARNUM keyword in the ACCEPT macro.
5-2
WRITING TO THE SYSOUT FILE
SYSOUT files are system output files, one of which is
created uniquely for each job”. Any user program
may write a one-line EBCDIC message on the
SYSOUT file for the job by means of the DISPL AY
macro. The location of the message buffer should be
specified on the related DISPLAY macro call.
DISPLAY expands to in-line processing code,
including an embedded block 1/0 WRITE to the
SY SOUT file.
*The Control Language Services Reference manuals contain
further explanations.
6. INTERACTION OF DATA MANAGEMENT
AND THE CONTROL LANGUAGE
Through the //DEFINE statement, a run-time
interaction between certain Data Management
services and Control Language services is provided.
This interaction gives the program independence from
reassembling to make changes that can then be made
at run-time through the control language statements.
Both the logical 1/0 level (described in Control
Program and Data Management Services, Basic
Reference) and the block 1/0 level require space
management. Users of the physical 1/0 level require
no space management. The Control Language and/or
the space management macros (ALLOC, EXPND, and
PURGE) can allocate, expand, or purge files.
If the Control Language is externally allocating a file,
the parameters are passed to the ALLOC packet by
the Step Initiator. A file is allocated by either the
ALLOC macro or by the //DEFINE statement, not
both. The ALL OC macro uses the FILENAME, MSC,
and VOLUME parameters specified in the //DEFINE
statement to override the parameter packet at
execution time. | |
A space management routine is called in response to a
service request from either the Control Language
processor or the user program. The Control Language
request for Allocate or Expand may be generated at
step initiation time using parameters given in the
//DEFINE statement. The Control Language request
for Purge may be generated at step termination time,
using parameters given in the pertinent files disc
catalog entry. The user program request for Allocate,
Expand, or Purge is generated at assembly time, using
parameters given as keyword in a macro call. The user
request may optionally make reference to
FILENAME, MSC, and VOLUME information given
in a //DEFINE statement. If so, at execution time,
the FILENAME and MSC parameters in the
//DEFINE statement override the equivalent
parameters contained in the user request.
Table 6-1 summarizes the use of different Control
Language parameters as used by the Step Initiator,
OPEN, CLOVE, ALLOC, EXPND, and PURGE.
Further explanations of the Control Language can be
found in Control Language Services, Extended
Reference.
6-1
6-2
Table 6-1. Summary of Data Management and Control Language Interaction
Control Language
Keyword Parameter
Control Language
Step Initiator
OPEN Macro
CLOVE Macro
ALLOC, EXPND,
PURGE Macros
IDENTIFIER
FILENAME
STATUS
MSC
DEVICE
VOLUME
(and IVOLUME
for OPEN)
SPREAD
CONTIGUOUS
LABEL
CSD
NUMBER
Not used
Used to search
central catalog to
determine volumes
of a cataloged file.
File usage checked
File type passed to
ALLOCATE packet*
if NUMBER is
specified.
Not used by Step
Initiator
Used to allocate
peripheral re-
sources to files.
Used to mount
packs or tape reels
when possible and
verify the mount
by comparison of
' volume with volume
identifier in the
volume label.
Passed to the
ALLOCATE packet*
Passed to the
ALLOCATE packet*
Not used by Step
Initiator
Used to compute
block size from
SIZE and BLOCK
for ALLOCATE
when NUMBER is
specified.
Used to compute
number of blocks
from BLOCK and
NUMBER for
ALLOCATE
Also indicates
need of ALLOC.
for partition conflicts.
Must match file
identifier in
OPEN macro.
Override DEFL.B
information.
Not used by OPEN
Override DEFLB
information.
Not used by OPEN
When volumes have
been mounted by
Step Initiator, they
are verified by
comparison with
unit table volume
identifier entries.
When not mounted,
OPEN mounts the
volume(s) and
| verifies against
volume label.
Not used by OPEN
Not used by OPEN
Indicates type of
label processing
for the job. Con-
trol Language
overrides program
specification.
Not used by OPEN
Not used by OPEN
Must match file
identifier in
CLOVE macro.
Override DEFLB
information.
Not used by CLOVE
Override DEFLB
information,
Not used by CLOVE
Used to mount and
verify successive
volumes of se-
quentia! files,
Not used by CLOVE
Not used by CLOVE
Indicates type of
label processing
for the job. Con-
troi Language
overrides program
specification.
Not used by CLOVE
Not used by CLOVE
Must match file identifier
in macro.
Override DEFLB informa-
tion.
Not used by ALLOC,
EXPND, or PURGE
Override DEFLB informa-
tion.
Not used by ALLOC,
EXPND, or PURGE
Volume identifiers specify
which packs are to be
used for allocation or
expansion. If omitted,
shared resources are
used. PURGE uses
volume identifiers for
purging uncataloged files.
Not used by ALLOC,
EXPND, or PURGE
Not used by ALLOC,
EXPND, or PURGE
Not used by ALLOC,
EXPND, or PURGE
Not used by ALLOC,
EXPND, or PURGE
Not used by ALLOC,
EXPND, or PURGE
the file.
*Parameters are passed to the ALLOCATE parameter packet by the Step Initiator; the Control Langu: ge is allocating
Table 6-1.
Summary of Data Management and Control Language interaction (Continued)
Control Language
Keyword Parameter
Control Language
Step Initiator
OPEN Macro
CLOVE Macro
ALLOC, EXPND,
PURGE Macros
SIZE
BLOCK
LOCATION
ORGANIZA-
TION
RETENTION
CATALOG
VERIFY
EXPAND
Used to compute
block size. Key
size portion is
passed to the
ALLOCATE
packet* for
indexed files.
Used to compute
block size for data
and index files.
Passed to the
ALLOCATE
packet* when
NUMBER is
specified.
Passed to the
ALLOCATE
packet*
Not used by Step
Initiator
Passed to the
ALLOCATE
packet*
Passed to the
ALLOCATE
packet*
Passed to the
EXPAND packet
Not used by OPEN
For tape files,
Control Language
supplies block size.
Default value is
251 bytes.
Not used by OPEN
Not used by OPEN
Used to generate
an expiration date
for tape files.
Not used by OPEN
If the file was
cataloged with
VERIFY=YES,
‘OPEN does not
interpret the param-
eter. If not, then
VERIFY=YES at
OPEN time will
temporarily over-
ride the catalog
attribute.
Not used by OPEN
Not used by CLOVE
Not used by CLOVE
Not used by CLOVE
Not used by CLOVE
Used to generate
an expiration date
for tape files.
Not used by CLOVE
Not used by CLLOVE
Not used by CLOVE
Not used by ALLOC,
EXPND, or PURGE
Not used by ALLOC,
EXPND, or PURGE
Not used by ALLOC,
EXPND, or PURGE
Not used by ALLOC,
EXPND, or PURGE
Not used by ALLOC,
EXPND, or PURGE
Not used by ALLOC,
EXPND, or PURGE
Not used by ALLOC,
EXPND, or PURGE
Not used by ALLOC,
EXPND, or PURGE
*Parameters are passed to the ALLOCATE parameter packet by the Step Initiator; the Control Language is allocating the file.
**Parameter is passed to the EXPAND parameter packet by the Step Initiator; the Control Language is expanding the file.
6-3
This section gives the specifications for the block and
physical 1/0 level functions of Data Management,
Block 1/0 action, Physical 1/0 action, and Control
Program Services. In general, all the macros have the
following format:
Name Operation Operand
The name field is an optional field which contains a
1- to 8-character alphanumeric file address. The first
six characters must be unique to accommodate the
standard suffixes used by the system. These are
discussed in Appendix B of this manual. The names
ident, labadr, and tag are used as identifiers for the
software function specified in the operation field of
the macro prototype.
The operand field contains keyword parameters
which may be in any order separated by commas.
Optional parameters are denoted by brackets, [ |.
Parameters with a choice of specifications are
denoted by braces, { |, and the default value is
underlined.
Fields are free-form and are separated by blanks;
thus, no imbedded blanks are allowed within the
parameter string. If more than one card is necessary, a
semicolon must appear after the last parameter on
_ each card except the last.
Symbolic address (as used in macro prototypes) is the
1- to 8-character symbol used to identify a coding
statement. The IDENT parameter is the symbolic
address of the 8-byte field containing the file
identifier (left-justified, blank filled). If the pertinent
file is defined in the Control Language, the file
identifier referenced by IDENT must be identical to
the IDENT specified by the //DEFINE statement.
Unless otherwise stated numbers are assumed to be in
decimal with no leading zeros.
DATA MANAGEMENT
In this section only the block and physical 1/0 level
of Data Management macros are given. This level of
macros include these:
7. MACROS
Block 1/0 Level Declarative Macro
DEFLB
Space Management Macros
ALLOC
EXPND
PURGE
File Control Macros
OPEN
CLOSE
CLOVE
1/0 Service Macro
LABRTN
Block 1/0 Macros
READ
WRITE
POSITN
CNTRL
STATUS
TYPE
RESET
Physical 1/0 Macros
EXCP
PCB
Control Program Macros
WAIT
DEL AY
INFORM
POST-
RPOST
SETCOM
GETCOM
ACCEPT
DISPLAY
MEMLIM
SETIF
HALT
EHALT
ABEND
TIME
SDATE
JDATE
e Console Communication Macros
CONSOLE
MESSAGE
Appendix B details the service request mechanism
and details the expansion of these macros.
BLOCK 1/0 LEVEL DECLARATIVE MACRO
A block 1/0 level declarative macro, DEFLB, defines
the file label for Data Management.
DEFLB — Define File Label
The DEFLB macro generates file label data into a
main-memory buffer for creating and checking disc
file names. The Control Language may also be used to
create and check file names. The block 1/0 level space
management and file control macros use DEF LB. The
format is as follows:
Name Operation Operand
labadr DEFLB FILENAM=name
[MSC=code]
FILENAM=name
Specifies a 1- to 17-character alphanumeric file name.
The first character may be A-Z, 0-9, or $; A-Z, 0-9,
and dash are allowed as succeeding characters. Index
file names are created internally by adding an asterisk
at the end of the associated data file name.
MSC=code (Optional)
Designates a 4-byte EBCDIC modification security
code, which is used for work and permanent files. If
omitted, blanks are assumed.
BLOCK МО LEVEL AND PHYSICAL МО LEVEL
EXECUTIVE REQUESTS
The executive request macros generate requests for
space management, file control, file processing, and
file positioning at the block 1/0 levei. These requests
specify a file identifier and a specific block of data
within the file. The file control and file processing
macros are also available at the physical 1/0 level,
specifying a unit identifier rather than a file
identifier.
Files which are open for block 1/0 level file
processing requests are described by a File
Description Table (FDT) created by OPEN. FDT
contains a physical description of the file, a 1- to
8-character file identifier, and current processing
information about the file (for example, current
block number and status of last request). File
processing and positioning requests are made by file
identifiers and controlled by the FDT.
Units which are open for physica! 1/0 level processing
are assigned by the Control Language. The identifier
field in OPEN is used to find the correct Control
7-2
Language entry which gives the unit assignment. The
//DEFINE statement indicates physical 1/0 by stating
PIO in the file name field. Physical 1/0 requests are
made by a unit ordinal which has been returned to
the user after an OPEN.
Space Management Macros
The ALLOC, EXPND, and PURGE macros manage
space for all disc files. Usually these three functions
are generated through the Control Language and by a
space management utility program, which allows
changes without recompilation of the program;
however, a user program can directiy manage file
space.
The allocation of paired files must be done through a
utility if not done directly from a user program. The
utility programs may also purge permanent and work
files if not done directly from the user program.
Space rnanagement is required for usage of block 1/0
level and logical 1/0 level interfaces. Users of physical
1/0 level require no space management.
Space is allocated in increments of tracks. Paired file
allocation of two files provides minimum arm
movement for file processing. A contiguous or
non-contiguous segment of space is allocated to.both
files starting at the chosen segment. Alternate tracks
from this space are then assigned to each of the two
files. File space allocated will be contiguous unless
contiguous space is unavailable, in which case up to
12 segments will be allocated. Other allocation
options are as follows:
e Multipack files (up to seven packs)
e Suppression of automatic segmentation
e Cylinder number specification
Each disc pack contains a volume label which is
created at disc initialization time. A MRX/OS utility
prograrn may change the volume label and its
parameters.
In its device label each disc pack contains pack status
indication of one of the following conditions.
Pack Status Meaning
Nonrestricted Any allocation request may
obtain space from this pack.
Restricted Only allocation requests with
packs specified by the Con-
trol Language may obtain
space from this pack.
Locked No further allocation is
allowed on this pack.
Some disc drives are classified as shared resource
drives at initial program load time. The operator
mounts a set of packs on these drives, which will be
available for any allocation requests. The remaining
disc drives (non-shared-resource drives) are each
assigned by job control to a specific user partition for
the job step requesting the drives, and may be used
only by allocation requests associated with the job
step in the partition to which they were assigned.
ALLOC — Allocate Space
The ALLOC macro allocates space for user data files
and system data files. When volume identifiers have
not been specified through job control, space will be
allocated on nonrestricted packs mounted on shared
resource drives. When volume identifiers have been
specified through job control, the disc drives on
which they are mounted will have been assigned by
job control to the partition (or system function) of
the program calling ALLOC. Duplicate file names are
not allowed on the disc catalogs. The format is as
foliows:
Name Operation Operand
[tag] ALLOC BLKSIZ=n
[CATALOG= [Y YES res)
[con- (no И,
[cso- [YES ||
YES
[Parar]
[ERR.COMP= NS )]
[FILEORG=code]
FILESIZ=n
- [FILETYP=code]
[IDENT=symbolic address]
YES
| iNDCYL- (no |]
n
INDSIZ=n*
KEYSIZ=n*
LABDEF1=symbolic address
[LABDEF2=symbolic address]
[ LisT= No ||
RECSIZ=n
С ETURN= {No H
[SPREAD=n]
| VERIFY- М ||
*For indexed files only.
BLKSIZ=n
Designates the number of 8-bit bytes per block for
the file. The value n ranges from 18 bytes through
32K bytes for magnetic tape and 7294 bytes for disc.
TES)
CATALOG=Í No
(Optional)
CATALOG=NO specifies that the file should not be
centrally cataloged. If omitted or CATALOG=YES,
the file is cataloged. The parameter is ignored for
scratch and temporary files.
vo |
con-{ YE
(Optional)
CON=YES specifies that contiguous space is to be
obtained. Absence of this parameter or CON=NO
allows segmentation.
кое
NO (Optional)
cso- |
CSD=YES (default case) specifies that the file will be
created with the common stored data format.
CSD=NO specifies that a data format other than CSD
will be used.
YES
(Optional)
DATACY {no
n
DATACY L=n designates a cylinder number boundary
for the beginning of the data file. The value n ranges
from 1 to 199. DATACYL=YES ensures the file
beginning on some cylinder boundary; whereas
DATACYL=NO does not. If the parameter is
omitted, the data file will not necessarily begin on a
cylinder boundary.
(Optional)
ERRCOMP=[ YO |
NO
ERRCOMP=YES specifies that the caller of the
request will examine return information on nonfatal
errors; therefore, nonfatal errors should not be
aborted by the system. Fatal errors such as illegal
instructions, irrecoverable memory parity errors,
privilege violations, and bound errors cause an
unconditional abort. If ERRCOMP=NO or is omitted,
no return information is examined.
FILEORG=code (Optional)
Determines the file organization. The possible codes
are as follows:
Code Organization
S Sequential
R Relative
| Indexed
If the code is omitted, sequential file organization is
used.
7-3
FILESIZ=n
Indicates an estimate of the number of blocks
expected in the data file.
FILETYP=code (Optional)
Designates the file type. The possible codes are as
follows:
Code Type
S Scratch
T Temporary
W Work
P Permanent
If the code is omitted, the temporary file type is
used.
IDENT=sy mbolic address (Optional)
Designates the 8-character file identifier. It should be
identical to the operand of the IDENTIFIER
keyword in a Control Language DEFINE statement
specifying the volume on which to allocate the file. If
IDENT does not match the IDENTIFIER
specification (or if omitted) and the file is to be
centrally cataloged, the file will be allocated on
shared resources. IDENT is required if the LABDEF1
parameter is not specified.
YES
INDCYL=< NO
n
(Indexed files only)
INDCYL=n specifies a cylinder number boundary for
the beginning of the index file. The value n ranges
from 1 to 199. INDCYL=YES ensures the file will
begin on some cylinder boundary; whereas
INDCYL=NO does not. If the parameter is omitted,
the index file will not necessarily begin on a cylinder
boundary.
INDSIZ=n (Indexed files only)
Specifies the estimated byte size of the index blocks.
The value of n ranges from 18 bytes to 7294 bytes.
KEYSIZ=n (Indexed files only)
Gives an estimate of the byte length of the primary
key for indexed files. The value of n ranges from 2
bytes to 100 bytes.
LABDEF1=symbolic address
Specifies the symbolic address of a file label area
which must correspond to the symbolic address
specified as the name field of the DEFLB macro.
LABDEF1 is required if the IDENT parameter is not
specified.
7-4
LABDEF2=symbolic address (Optional)
Specifies a second file label address for paired file
allocation requests. This option is available for
sequential and relative files only.
(Optional)
LISTE NO
NO
If LIST=YES, only the parameter packet is generated,
and the RETURN and ERRCOMP options are not
used. If LIST=NO, only the 2-byte standard executive
request instruction is generated. Loading of
general-purpose register 6 (R6) with the address of
the parameter packet and general-purpose register 7
(R7) with the save area address prior to issuing the
macro call is a user responsibility. If the LIST
parameter is omitted, both the execution request
instruction and the parameter packet are generated
following the macro call. Appendix B contains a
detailed discussion of the LIST parameter.
RECSIZ=n
Indicates the length of a logical record in bytes. The
value n ranges from 18 bytes through 32K bytes for
magnetic tape and 7294 bytes for disc. If omitted,
RECSIZ equals BLKSIZ.
(Optional)
YES
RETURN-| NG |
RETURN=YES specifies that the processor issuing
the executive request should be given control
(reactivated) as soon as the request is queued to its
destination routine. If RETURN=NO or if the
parameter is omitted, the calling processor is
reactivated when the request processing is complete
or terminates abnormally if ERRCOMP=YES.
SPREAD=n (Indexed files only)
Specifies the number of physical blocks separating
two logically consecutive blocks in the indexed data
file. The number of blocks between logically
consecutive blocks is one less than the n value whose
range is 1 through 10. If this parameter is omitted,
the logically consecutive blocks are adjacent.
(Optional)
VERIFY] NO |
NO
VERIFY=YES specifies read after write verification
of all writes to this file. If omitted or if
VERIFY=NO, write verification will not be a
permanent file characteristic. The VERIFY=YES
option may be specified as a temporary override
through logical level file definition macros or through
Control Language DEFINE statements at file open
time.
EXPND — Add Mass Storage Space
The EXPND macro obtains additional mass storage
space for sequential files. The file may be open but
cannot have input or update usage at the time of the
EXPND request. The format is as follows:
Name Operation ~~ Operand
YES
[tag] EXPND NO
[CATALOG=f
YES
NO
(YES
| ERRCOMP- NO } |
[FILESIZ=n]
[IDENT=symbolic address]
LABDEF=symbolic address
[con={
[YES
[List={ 07}
[PaiRED={( 07}
[ReruAN-( No À
CATALOG=|YES| (Optional)
CATALOG=NO specifies the file is not centrally
cataloged. If the parameter is omitted or
CATALOG=YES, the file is centrally cataloged. The
parameter is ignored for scratch or temporary files.
con-{ YS)
NO (Optional)
CON=YES specifies addition of contiguous space. If
absent or CON=NO, segmentation is allowed within
the space added.
(Optional)
ERRCOMP= NO |
NO
ERRCOMP=YES specifies that the caller of the
request will examine return information on nonfatal
errors; therefore, nonfatal errors should not be
aborted by the system. Fatal errors such as illegal
instructions, irrecoverable memory parity errors,
privilege violations, and bounds errors cause an
unconditional abort. If ERRCOMP=NO or if omitted,
no return information is examined.
FILESIZ=n (Optional)
Indicates the number of blocks to add to the file.
IDENT=symbolic address (Optional)
Specifies the 8-character file identifier. If the file is
open at the time of expansion, it must match the
name specified by the IDENT parameter of the OPEN
macro. If the file is closed, it should match the
operand of the IDENTIFIER keyword in a Control
Language DEFINE statement specifying a volume
identifier for expansion. If IDENT does not match
the IDENTIFIER specification (or if omitted) and
the file is centrally cataloged, the expansion will be to
the shared device. IDENT is required if LABDEF is
not specified. IDENT may be omitted only for
cataloged files.
LABDEF=symbolic address
Specifies the symbolic address of a file label which
must be identical to the label address of the DEFLB
macro. This parameter is required if the IDENT
parameter is not specified.
ves) (Optional)
NO
If LIST=YES, only the parameter packet is generated,
and the RETURN and ERRCOMP options are not
used. If LIST=NO, only the 2-byte standard executive
request instruction is generated. Loading of R6 with
the address of the parameter packet and R7 with the
save area address prior to issuing the macro call is a
user responsibility. If the LIST parameter is omitted,
both the executive request: instruction and the
parameter packet are generated following the macro
call. Appendix B contains a detailed discussion of the
LIST parameter.
LisT-|
(Optional)
PAIRED=Í NO |
NO
PAIRED=YES indicates the file is paired. If
PAIRED=NO or if the parameter is omitted, there is
no pairing of files.
(Optional)
RETURN (XS)
NO
RETURN=YES specifies that the processor issuing
the executive request should be given control
(reactivated) as soon as the request is queued to its
destination routine. If RETURN=NO or if the
parameter is omitted, the calling processor is
reactivated when the request processing is complete
or terminates abnormally if ERRCOMP=YES.
PURGE — Release Disc File Space
The PURGE macro releases the space allocated to a
disc file. For paired file allocation, both files are
purged. The format is as follows:
7-5
Name Operation Operand
[tag] PURGE [caTaLoG={ ES] ]
YES
[ERRCOMP-{ NO ||}
[IDENT=symbolic address]
LABDEF=symbolic address
[LIST= Evo
_ YES
[PAIRED= NO ]
[RETURN=XC )]
CATALOG= Foi (Optional)
CATALOG=NO specifies that the file is not centrally
cataloged. If the parameter is omitted or
CATALOG=YES, the file is cataloged. The parameter
is ignored for scratch and temporary files.
(Optional)
ER ACOMP= NO |
NO
ERRCOMP=YES specifies that the caller of the
request will examine return information on nonfatal
errors; therefore, nonfatal errors should not be
aborted by the system. Fatal errors such as illegal
instructions, irrecoverable memory parity errors,
privilege violations, and bounds errors cause an
unconditional abort. If ERRCOMP=NO or if omitted,
no return information is examined.
IDENT=symbolic address (Optional)
Specifies the 8-character file identifier. It must match
the operand of the IDENTIFIER keyword in a
Control Language DEFINE statement specifying the
volumes of the file purge. IDENT may be omitted
only for cataloged files. If omitted, Data Management
finds the file in the central catalog and then locates
the volumes.
LABDEF=symbolic address
Specifies the address of a file label, which must
correspond to the label address of the DEFLB macro.
This parameter is required if the IDENT parameter is
not specified.
veel
LIST= | NO
(Optional)
if LIST=YES, only the parameter packet is generated,
and the RETURN and ERRCOMP options are not
used. If LIST=NO, only the 2-byte standard executive
request instruction is generated. Loading of R6 with
the address of the parameter packet and R7 with the
7-6
save area address prior to issuing the macro call is a
user responsibility. If the LIST parameter is omitted,
both the executive request instruction and the
parameter packet are generated following the macro
call. Appendix 8 contains a detailed discussion of the
LIST parameter.
(Optional)
PAIRED=| NY
NO
PAIRED=YES indicates the file is paired. If the
parameter is omitted or PAIRED=NO, the file is not
paired.
(Optional)
RETURN=| No |
NO
RETURN=YES specifies that the processor issuing
the executive request should be given control
(reactivated) as soon as the request is queued to its
destination routine. If RETURN=NO or is omitted,
the calling processor is reactivated when the request
processing is complete or terminates abnormally if
ERRCOMP=YES.
FILE CONTROL
The file control macros — OPEN, CLOSE, and
CLOVE — direct data transmission. OPEN and
CLOSE control a file or unit at the block or physical
1/0 level. CLOVE performs volume switching at the
block 1/0 level.
OPEN — Open File for Data Transmission
The OPEN macro makes the file or unit assessible for
data transmission. The format is as follows:
Name Operation Operand
[tag] OPEN [BUFADR=symbolic address]
[ CONTROL=(A75 E) ]
Г ERRCOMP-{ © 1
IDENT=symbolic address
Гот]
[LABDEF=symbolic address]
[LisT{%o 1
[RETURN-( о |]
[nEmno-*59) |
[usace-f U |
BUFADR=symbolic address (Optional)
Specifies the address of a buffer for use in initiating a
file. BUFADR is required when USAGE=0 for block
I/O fevel openings of a relative file. The user generates
the desired data as dummy data in this buffer prior to
the OPEN request. The initialization is performed
only once. BUFADR is required if IOTYP=P.
0 Unit ordinal Length
2 | Unit Table Word 1
4 Unit Table Word 2
6
8 Volume Id
0
CONTROL (ANS, VE | (Optional)
CONTROL=NATIVE indicates that the control
characters are native to that particular device. ANSI
control characters are used if it is omitted or
CONTROL=ANS.
ER ACOMP-|
Xo |
NO (Optional)
ERRCOMP=YES specifies that the caller of the
request will examine return information on nonfatal
errors; therefore, nonfatal errors should not be
aborted by the system. Fatal errors such as illegal
instructions, irrecoverable memory parity errors,
privilege violations, and bounds errors cause an
unconditional abort. If ERRORCOMP=NO or is
omitted, no return information is examined.
IDENT=symbolic address
Specifies the 8-character file identifier. IDENT must
be identical to the operand of the IDENTIFIER
keyword in a Control Language DEFINE statement.
_[P
loTyP=| В |
(Optional)
Determines the type of I/O. IOTYP=P for physical
open. IOTYP=B (block open) creates the FDT for
block 1/0. The default value is B. If IOTYP=P, then
BUFADR must be specified. |
LABDEF=symbolic address
Specifies the address of a main-storage buffer that
contains a file label. The symbolic address should be
identical with the label address name specified in the
DEFLB macro. This parameter is ignored for files on
unit record or magnetic tape (tape labels are assigned
by the control! language). For disc files, label
information may have been specified by Control
Language DEFINE statements which override
LABDEF information. For temporary or scratch files,
the file name is concatenated with the job name.
ves) (Optional)
LisT=| YE
IF LIST=YES, only the parameter packet is generated,
and the RETURN and ERRCOMP options are not
used. !f LIST=NO, only the 2-byte standard executive
request instruction is generated. Loading of R6 with
the address of the parameter packet and R7 with the
save area address prior to issuing the macro call is a
user responsibility. If the LIST parameter is omitted,
both the executive request instruction and the
parameter packet are generated following the macro
call. Appendix B contains a detailed discussion of the
LIST parameter.
YES
NO (Optional)
RETURN-{
RETURN=YES specifies that the processor issuing
the executive request should be given control
(reactivated) as soon as the request is queued to its
destination routine. If RETURN=NO or is omitted,
the calling processor is reactivated when the request
processing is complete or terminates abnormally if
ERRCOMP=YES.
REWIND | XE2
NO (Optional)
REWIND=NO indicates that no initial rewind of
magnetic tape files is to be performed. If
REWIND=YES or is omitted, initial rewind is
performed.
USAGE=4 U
O
(Optional)
Specifies input (!), update (U), or output (O)
processing. Update usage is allowed for sequential
files only if the record type is fixed length and the
file is assigned to mass storage. The default value is |.
CLOSE — Close File for Data Transmission
The CLOSE macro removes the availability of the file
for data transmission. The format is as follows:
7-7
Name Operation Operand
[tag] CLOSE [ ERRCOMP= {no J]
IDENT=symbolic address
ет]
[LIST= [YES]
[ LOCK={n9 )|
[ RETURN= № ||
[REwno-[XES)
(Optional)
ER RcoMP=| CS)
NO
ERRCOMP=YES specifies that the caller of the
request will examine return information on nonfatal
errors; therefore, nonfatal errors should not be
aborted by the system. Fatal errors such as illegal
instructions, irrecoverable memory parity errors,
privilege violations, and bounds errors cause an
unconditional abort. If ERRCOMP=NO or is omitted,
no return information is examined.
IDENT=symbolic address
Specifies the 8-character file identifier. It must be
identical to the one specified in the OPEN macro.
loTve=| 4 (Optional)
Indicates the type of 1/0. IOTYP=P for physical
close. IOTYP=8 (block close) releases the FDT. The
default value is B.
(Optional)
LisT= [6
NO
If LIST=YES, only the parameter packet is generated,
and the RETURN and ERRCOMP options are not
used. If LIST=NO, only the 2-byte standard executive
request instruction is generated. Loading of R6 with
the address of the parameter packet and R7 with the
save area address prior to issuing the macro call is a
user responsibility. If the LIST parameter is omitted,
both the executive request instruction and the
parameter packet are generated following the macro
call. Appendix B contains a detailed discussion of the
LIST parameter.
(Optional)
Lock-| No |
NO
Specifies the disposition of the file. When
7-8
LOCK=YES is used, the FDT is flagged and OPEN
may not be executed again during the same job; files
assigned to magnetic tape are unloaded. When this
parameter is not used or LOCK=NO, the file may be
reopened from within the same job; files assigned to
magnetic tape may be rewound.
(Optional)
RETURN-| NO)
NO
RETURN=YES specifies that the processor issuing
the executive request should be given control
(reactivated) as soon as the request is queued to its
destination routine. If RETURN=NO or is omitted,
the calling processor is reactivated when the request
processing is complete or terminates abnormally if
ERRCOMP=YES. |
(Optional)
YES
REWIND= No
REWIND=NO specifies that magnetic tape files are
not rewound after closing. If the parameter is omitted
or REWIND=YES, the tapes are rewound/unloaded.
CLOVE — Close Volume
The CLOVE macro performs volume switching at the
block 1/0 level. It is used for sequential multivolume
files assigned to tape or disc. A user program may
close a volume at any time and switch to the next
sequential volume. CLOVE must be used when a
switch to the next volume is indicated by either an
EOF record or an end of space indicator from block
1/0.
CLOVE performs header and trailer label processing
on tapes, alternate unit processing on tapes, and disc
pack mounting and dismounting (via operator
control). The format is as follows:
Name Operation Operand
[tag] CLOVE [ ERRCOMP= {no | ]
IDE NT=symbolic : address
[LisT={ ra}
[ RETURN= No) ]
ERRCOM p=| No | (Optional)
ERRCOMP=YES specifies that the caller of the
request will examine return information on nonfatal
errors; therefore, nonfatal errors should not be
aborted by the system. Fatal errors such as illegal
instructions, irrecoverable memory parity errors,
privilege violations, and bounds errors cause an
unconditional abort. If ERRCOMP=NO or is omitted,
no return information is examined.
IDENT=symbolic address
Specifies the 8-character file identifier.
Yes)
isT-{ YE
(Optional)
If LIST=YES, only the parameter packet is generated,
and the RETURN and ERRCOMP options are not
used. If LIST=NO, only the 2-byte standard executive
request instruction is generated. Loading of R6 with
the address of the parameter packet and R7 with the
save area address prior to issuing the macro call is a
user responsibility. If the LIST parameter is omitted,
both the executive request instruction and the
parameter packet are generated following the macro
call. Appendix B contains a detailed discussion of the
LIST parameter.
(Optional)
RETURN (5)
NO
RETURN=YES specifies that the processor issuing
the executive request should be given control
(reactivated) as soon as the request is queued to its
destination routine. If RETURN=NO or if the
parameter is omitted, the calling processor is
reactivated when the request processing is complete
or terminates abnormally if ERRCOMP=YES.
1/O SERVICE MACRO
Data Management also has available |/O service
macros which can report the status information of
various aspects of the file.
LABRTN — Return File Label Information
The LABRTN macro returns the disc catalog
elements for uncataloged and cataloged files. The file
may be open or closed. LABRTN searches the FDT
string in partition first; and if there is no FDT,
LABRTN then searches the table created by the
Control Language DEFINE statement. If the IDENT
is found, then the proper disc file information is
returned in the buffer specified by the user in
INFOADR. If a LABRTN macro is issued against a
nondisc device and the IDENT specification matches
a Control Language //DEFINE statement. for a
nondisc device, LABRTN returns an error code and
returns the device type in the first byte of the user
buffer. The format is as follows:
Name Operation Operand
NAME
[tag] LABRTN | ]
[ eLEMENT-[ATTRIBUTE
ALL
_J YES
[ ERRCOMP={ J В
IDENT =symbolic address
INFOADR=symbolic address
(YES
[ LisT={ 0 11
_ [YES
[ RETURN={ No |
МАМЕ
ELEMENT={ ATTRIBUTE (Optional)
ALL
Specifies that the name element, attribute element, or
both elements will be returned in the buffer specified
by INFOADR. If the parameter is omitted, the
NAME element is returned. If ELEMENT=ALL is
specified, the name and attribute elements are
returned respectively. For an indexed file, the data
portion of the file is returned first and then the index
portion of the file.
ves) (Optional)
ER Rcowmp={ YE
ERRCOMP=YES specifies that the caller of the
request will examine return information on nonfatal
errors; therefore, nonfatal errors should not be
aborted by the system. Fatal errors such as illegal
instructions, irrecoverable memory parity errors,
privilege violations, and bounds errors cause an
unconditional abort. If ERRCOMP=NO or if omitted,
no return information is examined.
IDENT=symbolic address
Specifies the 8-character file identifier which was
used to open the file.
INFOAD R=symbolic address
Specifies the address of a main-storage buffer where
the information is returned.
vo
isT={ YE
(Optional)
If LIST=YES, only the parameter packet is generated,
and the RETURN and ERRCOMP options are not
used. If LIST=NO, only the 2-byte standard executive
request instruction is generated. Loading of R6 with
the address of the parameter packet and R7 with the
save area address prior to issuing the macro call is a
user responsibility. If the LIST parameter is omitted,
both the executive request instruction and the
parameter packet are generated following the macro
call. Appendix B contains a detailed discussion of the
LIST parameter.
1-9
YE
5 Optional
RETURN= [NG
RETURN=YES specifies that the processor issuing
the executive request should be given control
(reactivated) as soon as the request is queued to its
destination routine. If RETURN=NO or if the
parameter is omitted, the calling processor is
reactivated when the request processing is complete
or terminates abnormally if ERRCOMP=YES.
BLOCK INPUT/OUTPUT MACROS
READ
This macro transfers a block of data into the specified
buffer. If the location of the block is not explicitly
stated in the request, it will be generated by adding 1
to the block number last obtained (this applies to disc
and tape files only). If the preceding reference to this
file involved a WRITE or POSITN request, the
current block number is used without updating. When
the BLKNUM keyword is not used, the file is
addressed in a sequential manner.
Standard error recovery is provided, with
irrecoverable errors terminating the operation and
posting the return code in the request block.
Attempts to read outside of the portion of the file
which is currently accessible (current volume) will
result in an error.
Name Operation Operand
[tag] READ | IDENT=symbolic address
DATBUF=symbolic address
[DATSIZ=symbolic address]
[uisT=[ 0 1
[RETURN=( © | ]
[EnRcomP-{ a | ]
[escoic={X=%) |
[OPER=SSn]
[BLKNUM=symbolic address]
[muLTELK=f © À
IDENT=symbolic address
Specifies the address of a storage location containing
the file identifier — the name by which the file is
known to the program (as opposed to the external
catalog name specified through Control Language).
The file identifier must be eight bytes in length.
DATBUF=symbolic address
The address of the data buffer. Requests to disc
7-10
storage must specify a buffer which begins and ends
on word boundaries even though the data count may
be odd.
DATSIZ=symbolic address Optional
An address pointer to the number of bytes in the
buffer. If this is omitted, the block size defined for
the file is used as the byte count. The buffer size may
be up to 65,535 bytes. Any DATSIZ value given
which is greater than the device record size will result
in a nonzero residual count returned at the end of the
operation.
Optional
LISTO)
NO
To be used when either the system linkage (service
request instruction) or the parameter table is to be
generated separately. LIST=NO generates the service
request only; LIST=YES generates the parameter
table (list) only. When no LIST operand is specified,
both the service request and the parameter table are
generated.
Optional
RETURN={ (ES |
NO
To be used when the user program wishes to be given
control immediately on recognition of the request,
but before completion (RETURN=YES). When
RETURN=NO is coded, or the default is taken,
control will only be returned on completion of the
request.
Optional
ER Rcomp-{ oN
NO
To be used when the user decides to retain control in
the event of an error (ERRCOMP=YES). When
ERRCOMP=NO is coded, or the default is taken, the
program will be aborted if an error occurs.
The following parameters apply to the card reader
only.
EBCDIC= YES
NO Optional
This determines the type of conversion to be
performed on the data between card format and
memory format. If EBCDIC=YES, the translation is
made in accordance with the defined EBCDIC
formats. If EBCDIC=NO, the data on the card is
accepted in a binary format and is transferred to
storage without modification (card image storage
format, shown in Figure 7-1). If the parameter is
omitted the EBCDIC=Y-ES option is assumed.
Figure 7-1. Card Image/Storage Relationship
OPER=SSn Optional
Selects a stacker for the card read, designated by n.
The value n is determined by the hardware device
being used. This parameter is ignored except for card
readers with multiple stackers. If it is omitted, the
normal stacker is used.
The following parameter applies to magnetic tape and
disc files only. |
BLKNUM=address — Optional
The address of a four-byte hexadecimal field
containing the block number to be read. If it is
omitted, the current block number of the file is
updated by 1 before the READ, unless the last
operation was a WRITE* or POSITN, in which case
the current block number is used. Block numbers up
to 232-1 are allowed, but attempts to read beyond
the limits of a file (as defined by allocation) are
returned with return information noted.
Block numbers up to 232.1 are allowed, but attempts
to read beyond the limits of a file (as defined by
allocation) are returned with return information
noted. |
ves)
NO (Optional)
MULTBLK= |
If this operand is specified, as many disc records as
the program buffer will hold will be loaded. Any
remaining buffer space will be noted in the residual
count field.
*READ after WRITE on magnetic tape is illegal.
WRITE
This macro transfers a block of data from the
specified buffer to an 1/0 device. The location on the
I/O device where the data is to be placed may be
controlled by the BLKNUM keyword (disc), or the
current setting of the file block number will be used.
In either case, the file block number is updated after
the WRITE operation by adding 1 to the current
block number.
When writing to the line printer or card punch, the
first character of the user's buffer is used for carriage
or stacker control, and is deleted from the data line.
This feature may be overridden by the OPER option.
The first character of the buffer is still deleted from
the line.
Errors detected by the 1/0 routines initiate error
recovery procedures. If these fail to correct the error,
the return code is posted in the request block and the
operation is terminated.
Name Operation Operand
[tag] WRITE IDEN T=sy mbolic address
DATBUF=symbolic address
[DATSIZ=symbolic address]
[umm
[ RETURN=| YO? |
NO
YES
| ERRCOMP=IYE } ]
YES
[ escoic={ XE } |
[BLKNUM=symbolic address]
SKnn
| open (Srm ]
SSn
7-11
IDENT=symbolic address
Specifies the address of a storage location containing
the file identifier — the name by which the file is
known to the program (as opposed to the external
catalog name specified through Control Language).
The file identifier must be eight bytes in length.
DATBUF=symbolic address
Specifies the address of the data buffer. Requests to
disc must specify a buffer which begins a word
boundary.
DATSIZ=symbolic address Optional
The address of the memory word which contains the
byte count of the buffer. If it is omitted, the block
size defined for the file is used as the byte count. The
buffer size may be up to 65,535 bytes.
LiST=| Optional
ves)
NO
To be used when either the system linkage (service
request instruction) or the parameter table is to be
generated separately. LIST=NO generates the service
request only; LIST=YES generates the parameter
table (list) only. When no LIST operand is specified,
both the service request and the parameter table are
generated.
Optional
RETURN={ (5)
NO
To be used when the user program wishes to be given
control immediately on recognition of the request,
but before completion (RETURN=YES). When
RETURN=NO is added, or the default is taken,
control will only be returned on completion of the
request.
ER Rcomp-{ Optional
YES
NO
To be used when the user decides to retain control in
the event of an error (ERRCOMP=YES). When
ERRCOMP=NO is coded, or the default is taken, the
program will be aborted if an error occurs.
Magnetic Tape and Disc
BLKNUM=symbolic address Optional
The address of a four-byte hexadecimal field
containing the block number to be read. This
parameter is valid only for direct-access storage
devices. If it is omitted, the current block number of
the file is updated by 1 after the WRITE operation.
7-12
Block numbers through 232.1 are allowed, but
attempts to write beyond the limits of a file (as
defined by allocation) are returned with an error
indication.
Line Printer
OPER=SKnn Optional
Defines a carriage control tape channel to be used
when the data is written by a line printer. If the file is
not a printer file, the value of nn is converted to a
comparable ASA standard control character which
overlays the first character of the written block. If
the file is a printer file, this parameter overrides the
carriage operation specified by the first character of
the data record. Regardless of the method used, the
first character in the data buffer is deleted from the
print line.
OPER=SPnn Optional
Defines the number of print lines to be spaced after
printing. It is treated in a manner like that of the
OPER=SKnn parameter. From 1 to 15 lines may be
specified depending on hardware capabilities.
Card Punch
OPER=SSn Optional
Defines a stacker select operation to a card punch. If
this parameter is used, the first character in the data
buffer is written in the first position of the card. If
the parameter is not used, the first character in the
data buffer is treated as a stacker select code and is
deleted from the punch data. The absence of multiple
stackers on the card punch has no effect on this
procedure.
YES
NO Optional
escoic-|
This determines the type of conversion to be
performed on the data between card format and
memory format. With EBCDIC=YES, the translation
is made in accordance with the defined EBCDIC
formats. With EBCDIC=NO, the data on the card is
treated as being in a binary format (card image) and is
transferred from storage without modification
(Figure 7-1). If the parameter is omitted the
EBCDIC=YES option is assumed.
POSITN — Change Current Block Number
The POSITN request is used to change the current
block number for the file. The subsequent READ or
WRITE macro begins processing at the new block
number. POSITN is only allowed for files assigned to
disc storage or magnetic tape.
A POSITN on a magnetic tape file will always cause
the tape to be physically repositioned, whereas with
disc files a physical seek operation will not be
performed unless explicitly requested by SEEK=Y ES.
Name Operation Operand
[tag] POSITN IDENT=symbolic address
BOV
[ sumo | ]
sy mbolic:address
[ LIST= a} |
NO
[YES]
[ RETURN= NO H |
| YES) y
[ ERRCOMP={ (© H
YES
| SEEK={ 0
IDENT=symbolic address
Specifies the address of a storage location containing
the file identifier — the name by which the file is
known to the program (as opposed to the external
catalog name specified through Control Language).
The file identifier must be eight bytes in length.
BOV -
BLKNUM={EOV | Optional
symbolic address}
Specifies the block number at which the file is to be
positioned. BOV indicates beginning of volume, EOV
indicates end of volume™. If a symbolic address is
coded this is taken as the address of a four-byte field
containing the block number as an unsigned
hexadecimal number.
If this parameter is omitted, a position to BOV is
performed. Standard error recovery is provided, with
irrecoverable errors terminating the operation and
posting the exception indicator and return code in
the request block. A POSITN to block number 1 is a
request to position at the beginning of the file. A
POSITN to block number 0 will return an error. A
position to a block number above the highest block
currently mounted will also be returned with an
error; however, the file will be left positioned on the
last block of the volume or file.
LIST-| Optional
veel
NO
To be used when either the system linkage (service
request instruction) or the parameter table is to be
generated separately. LIST=NO generates the service
* For magnetic tape EOV indicates a position forward to the
first tapemark. For disc, BOV and EOV result in
positioning, across physical pack boundaries if necessary, to
the lowest (BOV) or highest (EOV} block number which is
currently described in the File Description Table,
request only; LIST=YES generates the parameter
table (list) only. When no LIST operand is specified,
both the service request and the parameter table are
generated.
No | | Optional
RETURN= [NS
To be used when the user program wishes to be given
control immediately on recognition of the request,
but before completion (RETURN=YES). When
RETURN=NO is added, or the default is taken,
control will only be returned on completion of the
request.
Optional
eRRcowp-| (ES)
NO
To be used when the user devices to retain control in
the event of an error (ERRCOMP=YES). When
ERRCOMP=NO is coded, or the default is taken, the
program will be aborted if an error occurs.
The following description applies only to disc storage.
Optional
seek={ vo |
NO
This parameter causes the disc drive arm to be
physically positioned on the cylinder in which the
specified block number is to be found. if the
parameter is omitted, the seek operation will be
performed when the following READ or WRITE
macro is executed and the POSITN will merely
update the block number. :
SEEK=YES should only be included when operating
on an unshared file; this is because the position of the
disc arm is not locked after a POSITN macro has been
executed, and with a shared file the arm could
therefore be repositioned by another user before data
transfer had begun. If the SEEK on POSITN
capability was not included in the operating system
(SYSGEN), this operand is ignored.
CNTRL — Hardware Control Operation
The CNTRL request is used to perform a specific
hardware control operation (this does not apply to
spooled files going to disc storage). The operations
allowed are dependent upon the device type.
Standard error recovery is provided, with
irrecoverable and logical errors terminating the
operation and posting the return code in the request
block. Control of the internal block number is
maintained where possible, but if an operation is
performed which does not maintain the block
number, any subsequent request which needs a block
number will be terminated with an error.
7-13
Name Operation Operand
[tag] CNTRL IDENT=symbolic address
(or
| RETURN={ YES}
YES
[ ERRcoMP={ No H
OPER=operation code
IDENT=symbolic address
Specifies the address of a storage location containing
the file identifier — the name by which the file is
known to the program (as opposed to the external
catalog name specified through Control Language).
The file identifier must be eight bytes in length.
Optional
{YES
LsT-{ XE |
To be used when either the system linkage (service
request instruction) or the parameter table is to be
generated separately. LIST=NO generates the service
request only; LIST=YES generates the parameter
table (list) only. When no LIST operand is specified,
both the service request and the parameter table are
generated.
ReTURN={ VES]
NO Optional
To be used when the user program wishes to be given
control immediately on recognition of the request,
but before completion (RETURN=YES). When
RETURN=NO is added, or the default is taken,
control will only be returned on completion of the
request.
YES
NO Optional
ERRCOMP=|
To be used when the user decides to retain control in
the event of an error (ERRCOMP=YES). When
ERRCOMP=NO is coded, or the default is taken, the
program will be aborted if an error occurs.
OPER=operation code
e Reader/Punch
OPER=SSn
Select stacker on a card reader/punch.
The numeric value of n is the stacker
number. This command may only follow
e Line Printer
OPER=SPnn
Space the printer form nn lines
immediately. From 1 to 15 lines may be
specified, depending on the hardware
capability.
OPER=SKnn
Skip to carriage control tape channel nn
immediately. :
The permissible values of nn are 1
through 12, corresponding to channels 1
through 12 of the printer carriage
control.
e Magnetic Tape
OPER=REW
Rewind tape. The internal block number
will not be maintained.
OPER=RUN
Rewind and unload tape. The block
number will not be maintained. |
OPER=ERG
Erase gap (write blank tape). The block
number will be maintained.
OPER=BSR
Backspace to interrecord gap. The block
number will be maintained.
OPER-FSR
Forward space to interrecord gap. The
block number will be maintained.
OPER=FSF
Forward space to tapemark (EOF). The
block number will not be maintained.
OPER=BSF
Backspace to tapemark (EOF) or to Load
Point if no tapemark is present. The
block number will not be maintained.
OPER=EOF
Write End-of-File mark (tapemark). The
block number will be maintained.
e Disc Files
OPER=EOF*
Write End-of-File mark (a record
containing a count field specifying a data
length of zero). When read, this record
7-14
a READ to a file opened for modify
usage.
*For disc, CNTRL will always write an EOF mark regardless
of whether the OPER=EOF operand is included or not.
will cause the system to set the EOF flag
in the request block and in the File
Description Table. The block number will
be maintained.
STATUS — Report of Status
This request causes the system to pass information to
a specified data buffer regarding the status of the file
at the completion of the last operation to the file.
Name Operation Operand
IDENT=symbolic address
BUFADR=symbolic address
BUFSIZ=symbolic address
[ LisT={ YES ]
[ RETURN=
[tag] STATUS
no |
No fl
[ ERRCOMP=| NO
IDENT=symbolic address
Specifies the address of a storage location containing
the file identifier — the name by which the file is
known to the program (as opposed to the external
catalog name specified through Control Language).
The file identifier must be eight bytes in length.
BUFADR=symbolic address
Specifies the address of the data buffer.
BUFSIZ=symbolic address
Specifies the address of the memory word containing
the byte count of the buffer.
Optional
LIST=1YOS)
NO
To be used when either the system linkage (service
request instruction) or the parameter table is to be
generated separately. LIST=NO generates the service
request only; LIST=YES generates the parameter
table (list) only. When no LIST operand is specified,
both the service request and the parameter table are
generated.
YES
RETURN-| NO Optional
To be used when the user program wishes to be given
control immediately on recognition of the request
but before completion (RETURN=YES). When
RETURN=NO is coded, or the default is taken,
contro! will only be returned on completion of the
request, |
Optional
ER ncomp={ ES]
NO
To be used when the user decides to retain control in
the event of an error (ERRCOMP=YES). When
ERRCOMP=NO is coded, or the default is taken, the
program will be aborted if an error occurs.
Between 20 and 24 bytes of file status information
are available from the system, depending on the type
of device (Table 7-1). The BUFSIZ specification
determines how much of this information is to be
returned, starting from the top of the table (this
could be less than the total amount available, if
specified).
Table 7-2 gives the information for the status word of
the Basic Data Channel operation; Table 7-3 gives the
status word for Disc Channel operation.
TYPE — Device and File Type
This request causes the system to pass two bytes of
information to the data buffer regarding the type of
file and the type of device for which this file is
prepared.
Name Operation Operand
[tag] TYPE IDENT=symbolic address
BUFADR=symbolic address
[risT-4XES)]
[ RETURN= 1551]
[ ERRCOMP={ © } ]
IDENT=symbolic address
Specifies the address of a storage location containing
the file identifier — the name by which the file is
known to the program (as opposed to the external
catalog name specified through Control Language).
The file identifier must be eight bytes in length.
BUFADR=symbolic address
Specifies the address of the data buffer.
7-15
7-16
Table 7-1. Returned Information Format
2 3 4 5 6 7 0 1 2 3 4 5 6 7
US B UD L SF Last BIO Function
Current Block Number
4
6 Error Field
8
10 Block Size
12 Pointer to Current Command Word
14 Status of Last 1/0 Operation
16 Residual Count
Disc:
PF PA WC No. of Residual Blocks
Highest Block Written (per volume)
Magnetic Tape:
18
20 Sense
22
Unit Record:
18 Sense Unit Ordinal
Table 7-1. Returned Information Format (Continued)
Byte | Bitls) | Field Name . Definition
0 1 Common stored data format flag (C) O = not common stored data format
1 = common stored data format
. 23 Usage Flag (US) 00 = input
01 = update
10 = output
4 Bypass Flag (B) O = no bypass
1 = bypass:
READ goes to EOF
WRITE is a NOP
5 Update Flag (US) 0 = not update mode
1 = update mode
6 Lockout Flag (L) 0 = no lockout
1 = file has been closed with lock
7 Sequential File Flag (SF) О = not sequential
1 = sequential
1 0-7 Last BIO Function Last function processed in BIO
2-5 0-7 Current Block Number (four bytes) — Block number after last function processed. If zero, current
0-7 block number is unknown
0-7
0-7
6,7 0-7 Error Field When this field is non-zero, a RESET macro must be issued
before making another request to the file
8 | 0 System Error Processing (EP) О = Call Error Recovery when an error is encountered
1 = Bypass Error Recovery
1,2 Not Used
3 FDT Restore (FR) 0 = FDT not restored
1 = FDT restored
4 Hold Up Flag (+) Set when file is in error recovery to prevent further requests
from being serviced
5-7 Not Used
9 0-7 Not Used
10,11 0-7 | Block Size Number of bytes in a physical record
7-17
Table 7-1. Returned Information Format (Continued)
Byte Bit(S) Field Name Definition
12,13 0-7 Current CW Pointer Address of the current or last command word executed on
this file
14,15 0-7 Status Status of last 1/0 operation (see Tables 7-2 and 7-3)
16,17 0-7 Residual Count (RC) The difference between the number of bytes requested and
the number of bytes transferred
Disc
18 0 Not Used
1 Paired File Flag (PF) 0 = not paired
1 = paired
2 Paired File Indicator (PA) O = first track of paired tracks
1 = second track of paired tracks
3 Write Check (WC) О = no write check
1 = write check on all writes
4 Disc Driver Flag Used internally by the driver only
5-7 Not Used
19 0-7 Residual Blocks Number of blocks remaining to be set up fora multiblock
read request which crosses tracks
20-23 0-7 Highest Block Written (HBW) Highest block number written for volume now mounted
0-7
0-7
0-7
Magnetic Tape
18-23 Sense Sense bytes of the device at time of last error
Unit Record
18 0-7 Sense Sense byte of the device at time of last error
19 0-7 Unit Ordinal (UORD) Unit table ordinal
7-18
Table 7-2. Status Word for Basic Data Channel Operations
Byte Bit Set to 1 Meaning
0 0 Attention
1 Status Modifier
2 Control Unit End
3 Busy
4 Channel End
5 Device End
6 Unit Check
7 Unit Exception
1 0 Initial selection sequence error, caused by one of the following:
Unit not there
Parity error on bus out
Bad address
Unit off-line
1 Main storage buffer not exhausted
2 Wrong Address-In returned on initial selection or bad parity on ‘ADDRESS IN’
3 No Request In on S10 Poll Sequence Request
4 Control check
5 Examine check (for data transfer only)
6 Invalid command or zero byte count
7 Unused
7-19
7-20
Table 7-3. Status Word for Disc Channel Operations
Byte Bit Set to 1 Meaning
0 0 IFA status not valid or command early
1 IFA missed window or command early
2 IFA window
3 IFA track boundary
4 IFA read/write termination
5 IFA burst check error
6 IFA lost data
7 IFA nosync compare
1 0 IFA 3rd rev sync find
1 Disc (not on line) or (seek incomplete and not file unsafe)
2 Disc (file unsafe) or {seek incomplete and not file unsafe)
3 Disc read only
4 Disc pack change
5 Disc end of cylinder
9 Disc write current sense or search fail (may be EOF)
7 Disc busy
All bits set Invalid function code in command program
Optional
LISTO
NO
To be used when either the system linkage (service
request instruction) or the parameter table is to be
generated separately. LIST=NO generates the service
request only; LIST=YES generates the parameter
table (list) only. When no LIST operand is specified,
both the service request and the parameter table are
generated.
| Optional
RETURN=| No |
NO
To be used when the user program wishes to be given
control immediately on recognition of the request
but before completion (RETURN=YES). When
RETURN=NO is coded, or the default is taken,
control will only be returned on completion of the
request.
Optional
ER rcomp-{ ES)
NO
To be used when the user decides to retain control in
the event of an error (ERRCOMP=YES). When
ERRCOMP=NO is coded, or the default is taken, the
program will be aborted if an error occurs.
The system responds to a TYPE request by placing
two bytes of file information in the buffer in the
following format:
0 12 3 45 6 7 8 15
US | B| UD| L|SF Device Type
The first byte of this word is the same as the first
byte returned by the STATUS macro. The second
byte is a value representing the device type as defined
following:
OF-2F input/output devices
20-3F input only devices
40-5F output only devices
60-7F input/output devices
80-FF communications devices
A more specific description of the bit significance in
the device type code is illustrated in Table 7-4.
ER RCOMP-|
RESET — Reset Exception Conditions
The RESET request allows a user to reset exception
conditions in the file description table. The exception
conditions lock out new 1/0 operations which would
overlay the exception status indications. Examples of
exception conditions are EOF and irrecoverable
hardware conditions.
Name — Operation Operand
[tag] RESET IDENT=symbolic address
[LisT={¥ES}]
[RETUAN=NS) ]
[ermcome-{ YES a
IDENT=symbolic address
Specifies the address of a storage location containing
the file identifier — the name by which the file is
known to the program (as opposed to the external
catalog name specified through Control Language).
The file identifier must be eight bytes in length.
LisT-{ No |
NO Optional
To be used when either the system linkage (service
request instruction) or the parameter table is to be
generated separately. LIST=NO generates the service
request only; LIST=YES generates the parameter
table (list) only. When no LIST operand is specified,
both the service request and the parameter table are
generated.
Мы
NO Optional
RETU aN-|
To be used when the user program wishes to be given
control immediately on recognition of the request,
but before completion (RETURN=YES). When
RETURN=NO is coded, or the default is taken,
control will only be returned on completion of the
request.
{YES
NO | Optional
To be used when the user decides to retain control in
the event of an error (ERRCOMP=YES). When
ERRCOMP=NO is coded, or the default is taken, the
program will be aborted if an error occurs.
7-21
Table 7-4. Bit Significance
8 9 10 11 12 13 14 15 Bit assignment
0 0 0 1 0 x a Card Reader/Punches
0 0 1 0 0 X a Card Readers
0 1 0 0 0 X a Card Punches
0 1 О 1 X X a Line Printers
0 1 1 0 X X a Magnetic Tape Units
0 1 1 1 0 X X Disc Drives
1 0 0 0 0 x X Communications Devices
modifier bit
PHYSICAL INPUT/OUTPUT MACROS
EXCP — Input/Output Action
Name Operation Operand
_ | @register number
[tag] EXCP [Pes fo address \]
_ | @register dro y
[cp Cr address ]
[UNOR D=symbolic address |
[ RETURN of
[ ERRCOMP={ 0 17
This is the physical 1/0 action macro (the “do 1/0”
macro). Basically, it generates the service request
necessary to execute a command program in
conjunction with a Physical Control Block (PCB) and
for this purpose does not necessarily require any
operands. However, it should be noted that two
preconditions must be satisfied before the EXCP can
function properly:
e general register 6 must be loaded with a
pointer to the associated PCB
e the appropriate command program address
must be loaded into the PCB
If these two conditions are not already satisfied at the
time the macro is issued, the following optional
operands may be included in the macro for this
purpose.
7-22
1 means hardware-buffered device
1 means early termination {on channel end rather than device end)
@register number
РСВ= symbolic address
Optional
This operand specifies the address of the PCB. If the
parameter is omitted, the PCB location is assumed to
be R6. An alternate register or a symbolic address
may be designated to give the location of the PCB.
The use of this keyword causes the contents of R6 to
be destroyed.
_ | @register number
"| symbolic address Optional
This operand specifies the address of the appropriate
command program. If this operand is omitted, the
command program address is assumed to be in the
PCB. If the keyword is used, a register (other than
R6) or a symbolic address may specify the location of
the command program to be executed. if the
keyword is specified, the address of the command
program is moved to the CPADR area in the PCB.
UNOFiD=sy mbolic address Optional
The operand must point to a user location containing
the unit ordinal of the device on which the operation
is to be performed. This will normaily be the same
address as the buffer specified in the physical OPEN
macro associated with the device, since OPEN returns
this value.
RETURN | “y Optional
To be used when the user program wishes to be
given contro! immediately on recognition of the
request, but before completion (RETURN=YES).
When RETURN=NO is coded, or the default is
taken, control will only be returned on completion
of the request.
Optional
ERRCOMP= | NO
NO |
To be used when the user decides to retain control in
the event of an error (ERRCOMP=YES). When
ERRCOMP=NO is coded, or the default is taken, the
program will be aborted if an error occurs.
PHYSICAL CONTROL BLOCK
This is a data macro which generates the Physical
Command Block necessary for performing a physical
input/output operation.
Name Operation Operand
[tag] PCB [CPADR=symbolic address]
[ ERROPT=1XES) ]
(TAPE
[ DEVTYP={ UREC
DISC
wens JASKATT
[ FUNCTN= O ovES À
[YES
ER RoPT-| NO Optional
Determines whether system error recovery is to be
employed in the event that an error occurs when the
command program is executed (by an EXCP macro).
MT
UR .
DEVTYP= DISC Optional
comm’
Determines how much space is to be reserved in the
generated PCB to receive sense information.
e MT reserves three words
e UR reserves one word
e DISC and COMM reserve no space
e Omitting the DEVTYP operand causes
reservation of three words
In the event that an uncorrectable error occurs, sense
information will always be returned to the PCB and
the user may then use this information for his own
error processing provided that ERRCOMP=YES was
coded in the corresponding EXCP macro.
CPADR=symbolic address | Optional
This parameter specifies the location of the command
program to be used with this PCB. The symbolic
address should be the label used on the command
program. If this parameter is omitted, the PCB will be
assembled without a command program address; then
this address must therefore be supplied dynamically
at execution time by the corresponding EXCP macro.
ASKATT
REMOVE Optional
FUNCTN-|
This optional parameter is used for executing
functions which do not require a command program.
When this parameter is coded the CPADR parameter
is not required and will be ignored if present.
FUNCTN=ASKATT causes the program to wait for
an asynchronous attention from the device {such as
disc pack change, line printer ready, magnetic tape
loaded). If no attention is received following a
FUNCTN=ASKATT request, the outstanding request
must be cleared before the end of the job by issuing a
FUNCTN=REMOVE request. FUNCTN=REMOVE
clears all ASKATT requests from the particular device
and returns them with an explanatory error code (see
Appendix C).
NOTE
Since the completion of a FUNCTN=ASKATT
request is dependent on outside action
(operator, hardware) care should be exercised
in its use (it is possible to give up control and
never regain it).
REMOVE and ASKATT functions cannot be chained.
COMMAND
This single macro will generate a command word (or
words)* for a physical input/output operation on
unit record, magnetic tape, disc or communications**
devices. Since the macro takes a wide variety of
possible forms according to the type of device and
operation for which it is being used, separate
descriptions are given for each of the different classes
as reflected in the value of the OPCODE operand.
* The generated word is not directly executable code and
must therefore be coded in a data area of the user's
program.
** Details in Telecommunications Reference manual.
7-23
COMMAND Macro for Basic Data Channel
(Unit Record Devices and Magnetic Tape}
This macro generates a command word for physical
input/output operations on card reader, card punch,
line printer, magnetic tape, etc. (devices connected to
the basic data channel). The generated command
word specifies the hardware operation to be executed
and, for commands that require data transfer, it
designates the storage area associated with the
operation. In addition, various operation modifiers
may be supplied.
Name Operation Operand
[tag] COMMAND OPCODE=X'nn'
[BUFADR=symbolic address]
[BUFSIZ=decimal number]
| [cHAIN- Ino ||
_ [YES
[SıZERR= NO ||
[skip Ma
OPCODE=X "nn"
This parameter is a two-digit hexadecimal code
specifying the hardware operation to be performed
(see Table 7-5), or a command program jump
command (OPCODE=X'08").
BUFADR=symbolic address Optional
Specifies the address of the data buffer.
BUFSIZ=decimal number Optional
Specifies the length of the data buffer in bytes. The
maximum allowable value is 65,535 bytes. BUFSIZ=0
is not valid at execution time.
No |
CHAIN= Na Optional
Indicates that another command word follows
contiguously. Omission of this operand indicates that
this is the last (or only) command word in the
command program. CHAIN=NO represents the
command word being the last one in the command
program.
YES
NO Optional
ванне |
Any difference between the length of the data record
processed at the hardware-software interface and the
size of the data buffer is detected by the 1/0 routines.
This “incorrect length indication” is normally treated
as an error condition and causes termination of a
command program at that point. The SIZERR=YES
operand (suppress length check) allows chaining to
7-24
proceed regardiess. SIZERR=NO causes termination
of a command program at that point.
SKIP= {-
YES
NO | Optional
SKIP=YES causes suppression of the transfer of data
into storage during this command word execution.
SKIP=NO causes the transfer of the data storage.
COMMAND
Macro for DCABLE Operation
Creates a command word for a physical disc
operation to return the disc drive cable address. When
an EXCP executes this command word it will read the
status of the physical device identified in the related
PCB and will place status indication in a two-byte
buffer specified by BUFADR.
Name Operation Operand
[tag] COMMAND OPCODE=DCABLE
BUFADR=symbolic address
_JYES
[CHAIN= | NO
OPCODE=DCABLE
Operation code for returning disc drive cable address.
BUFADR=symbolic address
Specifies the two-byte buffer area where the disc
drive cable address will be returned.
YES
NO Optional
CHAIN= |
Indicates that another command word follows
contiguously in storage and is to be executed
immediately after this one. CHAIN=NO represents
the command word being the last one in the
command program.
COMMAND Macro for a DCSEEK Operation
Creates a command word for a physical disc seek
operation. When executed by an EXCP, this
command word will cause a disc seek to the cylinder
and track specified in a buffer pointed to by
BUFADR.
Name Operation Operand
[tag] COMMAND OPCODE=DCSEEK
BUF ADR=symbolic address
YES
[CHAIN= { мо |]
OPCODE=DCSEEK
Operation code for a disc seek.
Table 7-5. Peripheral Device Basic Hardware Operation Codes
Device Operation OPCODE
Card Reader (8010) Read (and Feed):
EBCDIC mode 02
Card Image mode 22
Test 1/0 00
No Operation 03
Sense 04
Line Printer (5120, 5060) Write (no line spacing) 01
Write and Space
Space 1 line 09*
Space 2 lines 11
Space 3 lines 19
Space 4 lines 21
Space 14 lines 71
Space 15 lines 79
Space Immediate:
Space 1 line 0B*
Space 2 lines 13
Space 3 lines 1B
Space 4 lines 23
Space 14 lines 73
Space 15 lines 78
Write and Skip:
Skip to Channel 1 (top of form) 89*
Skip to Channel 2 91
Skip to Channel 3 99
Skip to Channel 4 A1
Skip to Channel 11 D9
Skip to Channel 12 E1
Skip Immediate:
Skip to Channel 1 (top of form) 8B*
Skip to Channel 2 93
Skip to Channel 3 98
Skip to Channel 4 A3
Skip to Channel 11 DB
Skip to Channel 12 E3
Test 1/0 00
No Operation 03
Sense 04
*These numbers in the series are being incremented by eight.
7-25
Table 7-5. Peripheral Device Basic Hardwars Operation Codes (Continued)
Device Operation OPCODE
Card Reader/Punch (8025) Read Only:
EBCDIC mode OA
Card Image mode 2A
Feed and Select Stacker:
without offset 23
with offset A3
Read, Feed and Select Stacker:
EBCDIC mode, without offset 02
EBCDIC mode, with offset 82
Card Image mode, without offset 22
Card Image mode, with offset A2
Punch, Feed and Select Stacker:
EBCDIC mode, without offset 01
EBCDIC mode, with offset 81
Card image mode, without offset 21
Card Image mode, with offset A1
Test 1/0 00
No Operation 03
Sense 04
Magnetic Tape (3237) Write Forward 01
Read Forward 02
Rewind 07
Rewind.and Unload OF
Backspace:
Block 27
File 2F
Forward Space:
Block 37
File 3F
Write Tapemark (End-of-File) 1F
Erase Gap 17
Force Error Mode:
Set E3
Clear D3
Test 1/0 00
x5
No Operation X6
XD
XE
Sense 04
7-26
BUF ADR=symbolic address
This specifies the address of a four-byte buffer which
is assumed to have been preset by the user with the
cylinder and track numbers to which the seek is to be
made. The buffer format should be:
0 7 0 7
FBA Cylinder number
FBA+2 Track number
YES .
CHAIN= № | Optional
Indicates that another command word follows
contiguously in storage and is to be executed
immediately after this one. This parameter must be
included to reserve the unit until the subsequent data
transfer is complete. CHAIN=NO represents the
command word being the last one in the command
program.
COMMAND Macro for a DCSRCH Operation
Creates a command word for a physical disc search
operation. When executed by an EXCP, this
command word causes a disc search to be performed.
The search command allows the user to locate, on the
current track, the data he wishes to process. This is
done by analyzing the physical track records for type
and content, searching for the record specified by
BUFADR. When the specified record is found, the
next contiguous command word in the command
program is executed”. If the search fails to find the
specified record on the track, the command program
is discontinued at this point and the abnormal
completion bit is set in the request block.
Name Operation Operand
[tag] COMMAND OPCODE=DCSRCH
BUFADR=symbolic address
BUFSIZ=decimal number
HA
[FIELD= {RZCNT; ]
RNCNT
| CHAIN= { No
OPCODE=DCSRCH —
Operation code for a disc search.
*This will normally be a DCREAD or DCWRIT to read or
write the actual data record associated with the search. The
search should always be made for a field (usually a count
field) preceding the record to be processed. Appendix E
contains further information on the organization and
structure of physical disc records.
BUFADR=symbolic address
Specifies the address of a buffer containing the data
to be used in comparing to the field being searched.
This buffer must begin on a word boundary:
BUFSIZ=decimal number
Specifies the length of the field being searched for.
HA
FIELD={ RZCNT Optional
RNCNT
Specifies the type of field for which to search.
HA=home address, RZCNT=count field of record
zero and RNCNT=count field of record n. if this
parameter is omitted, HA is assumed. Following is a
table specifying the field to search in order to read or
write a desired field.
To Perform
this DCREAD This DCSRCH
or DCWRIT Operation is
Operation: First Required:
HA No search required
Data RNCNT
Key + Data RNCNT
Count R(N-1)CNT or HA
Count + Data | R(N-1)CNT or HA
Count + Key + | R(N-1) CNT or HA
Data
Note that, when searching in preparation for a write
operation, any fields that may be situated between
the search field and the field to be written must be
skipped using a DCREAD without transfer.
Optional
CHAIN=[ NO |
No
Indicates that another command word follows
contiguously in storage and is to be executed
immediately after this one (almost always the case
with the DCSRCH). CHAIN=NO represents the
command word being the last one in the command
program.
7-27
COMMAND Macro for a DCREAD Operation
Creates a command word or chained group of
command words for a physical disc read operation.
When executed by an EXCP instruction, this
command word (or group of command words) will
cause a field (or number of fields) to be copied from
disc into the specified buffer (or buffers). A
multi-record data field read may be specified by
including a BUFSIZ parameter which is a multiple of
the DATSIZ parameter. However, when this is done,
no other fields may be read by the same macro.
Name Operation Operand
[tag] COMMAND OPCODE=DCREAD
HABUF=sy mbolic address,
HASIZ=decimal number
DATBUF=symbolic address,
DATSIZ=decimal number
KEY BUF=symbolic address,
KEYSIZ=decimal number
CNTBUF=symbolic address,
CNTSIZ=decima! number
[BUFSIZ=decimal number]
Гэк- [15°]
[cHAIN=( E"
NO
[rieco- {nent} ]
OPCODE=DCREAD a
Operation code for a disc read.
HABUF=symbolic address Optional
HASIZ=decimal number
These two parameters are coded as a pair to indicate
that a home address field is to be read. HABUF
specifies the address of the buffer into which the
home address is to be placed and HASIZ specifies the
buffer length in bytes.
DATBUF=symbolic address Optional
DATSIZ=decimal number
These two parameters are coded as a pair to indicate
that a data field is to be read. DATBUF specifies the
address of the buffer and DATSIZ specifies the length
of the buffer, except in the case of multi-record reads
(see BUFSIZ).
KEYBUF=symbolic address Optional
KEYSIZ=decimal number
These two parameters are coded as a pair to indicate
that a data field is to be read. KEYBUF specifies the
address of the buffer, and KEYSIZ its length.
CNTBUF=symbolic address Optional
CNTSIZ=decimal number
7-28
These two parameters are coded as a pair to indicate
that a count field is to be read. CNTBUF specifies the
address of the buffer, and CNTSIZ its length in bytes.
BUFSIZ=decimal number Optional
This parameter is to be coded for multi-record reads
only. It indicates the overall length of the data buffer
(DATBUF); it should be a multiple of the value of
DATSIZ.
YES
NO Optional
SKIP= |
When this parameter is included no data will be
transferred to memory so that fields may be skipped
and/or the cyclic burst bytes” of a record may be
checked. The SKIP=NO option (default) reads data
into the buffer area.
Optional
неко- [BZENT]
RNCNT
This option gives the record in the count field.
FIELD=RZCNT is record 0 in the count field;
FIELD=RNCNT is record n in the count field.
Optional
CHAIN= (No |
NO
Indicates that another command word follows
contiguously in storage and is to be executed
immediately after this one. CHAIN=NO (default)
represents the command word being the last one in
the command program.
The following table illustrates the valid combinations
of parameters which may be coded in a DCREAD
macro. (In all cases SKIP=YES may be included to
suppress data transfer.) |
Multi-
Record
Operation Buffer (BUFSIZ)
Read Home HABUF No
Address
Read Data DATBUF Yes
Read Key KEYBUF+DATBUF | No
and Data
Read Count — CNTBUF No
Read Count CNTBUF+DATBUF No
and Data
Read Count, CNTBUF+KEYBUF | No
Key and Data +DATBUF
* Appendix E has further details.
COMMAND Macro for a DCWRIT or.
DCFWRIT Operation
Creates a command word or a chained group of
command words for a physical disc write operation.
When executed by an EXCP instruction, this
command word (or group of command words) will
cause data contained in the specified buffer (or
buffers) to be transferred to the specified field (or
fields) on disc.
Note that with physical write operations to disc it is
always necessary to specify the length of the variable
gap which is to be written preceding a count field, or
the fixed length gap preceding the home address field.
Name Operation Operand
| DCWRIT
[tag] COMMAND OPCODE= [5 CEWRIT|
HABUI-=symbolic address,
HASI Z=decimal number
DATBUF=symbolic address,
DA TSI Z=decimal number
KEY BUF=symbolic address,
KEYSIZ=decimal number
CNTBUF=symbolic address,
CNTSIZ=decimal number
[GAP=hexadecimal number]
YES 7)
| cHAIN= { NO }]
RZCNT }]
| FIELD= lanont
оРсоре- Оси
DCFWRIT
Operation code for a disc write. OPCODE=DCWRIT
specifies a normal write operation,
OPCODE=DCFWRIT specifies a "format write’: this
is the same as a normal write except that, on
completion, the rest of the track (up to the index
mark) is filled with 1's (equivalent to a continuous
gap).
Optional
HABUF=symbolic address | Optional
HASIZ=decimal number
These two parameters are to be coded as a pair to
indicate that a home address field is to be written.
HABUF specifies the address of the buffer containing
the data to be written into the home address, and
HASIZ specifies the buffer length in bytes.
DATBUF=symbolic address Optional
DATSIZ=decimal number
These two parameters are to be coded as a pair to
indicate that an actual data record is to be written.
DATBUF specifies the address of the buffer
containing the data to be written, and DATSIZ
specifies its length in bytes.
KEYBUF=symbolic address Optional
KEYSIZ=decimal number
These two parameters are to be coded as a pair to
indicate that a keyfield is to be written. KEYBUF
specifies the address of the buffer containing the data
to be written, and KEYSIZ specifies its length in
bytes. |
"CNTBUF=symbolic address Optional
CNTSIZ=decimal number
These two parameters are to be coded as a pair to
indicate that a count field is to be written. CNTBUF
specifies the-address of the buffer containing the data
to be written, and CNTSIZ specifies its length in
bytes. Note that whenever a count field is to be
written its associated variable gap length must be
calculated.
— GAP=decimal number Optional
The value of this parameter represents the length in
bytes of an inter-field gap. The length of the gap will
be fixed except when a count field is being written,
in which case it must be calculated from the lengths
of the preceding key and data fields on the track (see
the following table). Appendix D gives the gap
specifications. `
The following table illustrates the decimal number
values given for the gaps preceding these values.
Value to be
Coded in
Operation Buffer GAP Operand
Write home HABUF 32
address
Write data DATBUF 0
Write key KEYBUF+DATBUF 0
and data
Write Count CNTBUF
Write count CNTBUF+DATBUF (K+D)x.043
and data
Write count, | CNTBUF+KEYBUF
key and data: +DATBUF
K = length of preceding key field
D = length of preceding data field
7-29
Optional
CHAIN= No |
NO
Indicates that another command word follows
contiguously in storage and is to be executed
immediately after this one. CHAIN=NO represents
the command word being the last in the command
program.
RZCNT | Optional
FIELD= [ro
This option gives the record in the count field.
FIELD=RZCNT is record O in the count field;
FIELD=RNCNT is record n in the count field.
COMMAND Macro for a RESTORE
Operation
Creates a physical command word which, when
executed by an EXCP, causes a disc restore operation.
Name Operation Operand
[tag] COMMAND OPCODE=RESTORE
OPCODE=RESTORE
Operation code for a disc restore.
COMMAND Macro for a DCJUMP Operation
Creates a physical command word which, when
executed by an EXCP, causes the EXCP to next
execute the command word located at the address
specified by CWADR. This may be used to link
command programs.
Name Operation Operand
[tag] COMMAND OPCODE=DCJUMP
CWADR=symbolic address
CWAD R=symbolic address
Specifies the address of the command word which 1s
to be executed immediately following this one.
CONTROL PROGRAM MACROS
WAIT — Wait for Service Request Completion
This macro is used to wait for the completion of one
or more outstanding service requests. Execution of
the requesting program will be suspended until
completion of the specified request(s)”. Except for
7-30
the optional LIST and ERRCOMP, only one other
operand may be coded with this macro; depending
upon the particular parameter used, the macro will
wait for completion of:
e any one of the outstanding requests (MODE
= ANY) |
e all of the outstanding requests (MODE
ALL)
e a specific outstanding request (REQADR
symbolic address)
K
Note that when the REQCNT option is used the
WAIT macro is satisfied on any of the following
conditions:
e When the WAIT macro is issued and the
system detects that no requests are
outstanding.
e when the WAIT macro is issued and the
count of outstanding requests is not equal to
that specified by REQCNT
e otherwise, when the first of any outstanding
request operations is completed
Name Operation Operand
al
[tag] WAIT [MODE | ]
[REQADR=symbolic address]
[REQCNT=symbolic address]
[List={ E51]
[ERACOMP=] NS |]
Optional
ALL Р
This operand provides the option of waiting for the
completion of any one or all of the currently
outstanding requests.
MODELA
REQADR=symbolic address Optional
This operand should be used when it is desired to
wait for the completion of a single specific request.
The symbolic address must be the address of the first
word in the request block (parameter list) of the
specific request to wait for (not service request
instruction itself).
REQCNT=symbolic address Optional
This operand specifies the location of a one-byte field
containing the hexadecimal count of the number of
requests known to be outstanding. Use of this
operand gives a wait for the completion of any service
request.
* If none of the specified requests is outstanding at the time
the WAIT is executed, control will be returned immediately
to the requesting program.
Optional
us| Мы
NO
To be used when either the system linkage (service
request instruction) or the pararneter table is to be
generated separately. LIST=NO generates the service
request only; LIST=YES generates the parameter
table (list) only. When no LIST operand is specified,
both the service request and the parameter table are
generated in line.
Optional
ER Rcomp-{ vo |
NO
To be used when the user decides to retain control in
the event of an error (ERRCOMP=YES). When
ERRCOMP=NO is coded, or the default is taken, the
program will be aborted if an error occurs.
DELAY — Suspend Program Executiont
This macro causes program execution to be
suspended for a specified period of time, with the
option of resuming on completion of any outstanding
service request. The period of suspension may be
specified either by the SECONDS operand or by the
CYCLES operand (one of which is always required).
Name Operation Operand
[tag] DELAY SECONDS=sy mbolic address
CYCLES=symbolic address
[BREAK= fno À
ar E
[ERRCOMP= Ne.
SECONDS=symbolic address Optional
Specifies the location of a one-word field containing
the desired delay in seconds (hexadecimal).
CYCLES=symbolic address Optional
Specifies the location (hexadecimal) of a one-word
field containing the desired delay in cycles (one cycle
= 50.2 milliseconds).
=
BREAK=YES indicates that program execution is to
be resumed immediately after any outstanding service
request is completed. When this operand is omitted or
BREAK=NO, the program will be resumed only when
the specified delay time has elapsed.
BREAK= { Optional
Tt Not available on minimal system.
Optional
LIST= Ny
NO
To be used when either the system linkage (service
request instruction) or the parameter table is to be
generated separately. LIST=NO generates the service
request only; LIST=YES generates the parameter
table (list) only. When no LIST operand is specified,
both the service request and the parameter table are
generated.
NO | Optional
ER RCOMP=Í NO
To be used when the user decides to retain control in
the event of an error (ERRCOMP=YES). When
ERRCOMP=NO is coded, or the default is taken, the
program will be aborted if an error occurs.
INFORM — Service Request Completed
The INFORM macro informs the requesting program
that one of the program's outstanding service requests
has been completed. INFORM returns control
immediately to the user and subsequently indicates
that a service request has been completed by setting
the complete bit in the INFORM request block (bit O
of the third byte of the parameter list). The REQCNT
operand points to a location containing a one-word
count of the number of service requests which are not
known to have been completed. The purpose of the
count specification is to indicate whether any of the
requests whose completion status is unknown have
already been completed by the time the INFORM
macro is executed (this will include the possibility of
a request being completed in the interval between the
issuance and actual processing of the INFORM). Thus
the INFORM macro is satisfied by any one of the
following conditions:
e when no service requests are outstanding
e when the number of outstanding requests is
less than that specified by REQCNT
e when the first outstanding request is
completed
IF when INFORM is issued, the number of
outstanding requests exceeds the REQCNT
specification, an error is assumed and the INFORM
request is completed as abnormal.
Name Operation Operand
[tag] INFORM REQCNT=symbolic address
[ LIST=N MES Y]
[ ERRCOMP-1 NO" a
7-31
REQCNT=symbolic address
Specifies the address of a one-byte location
containing the number of service requests that are not
known to have completed (outstanding).
Optional
LIST= My
To be used when either the system linkage (service
request instruction) or the parameter table is to be
generated separately. LIST=NO generates the service
request only; LIST=YES generates the parameter
table (list) only. When no LIST operand is specified,
both the service request and the parameter table are
generated.
YES
ER =
RCOMP № | Optional
To be used when the user decides to retain control in
the event of an error (ERRCOMP=YES). When
ERRCOMP=NO is coded, or the default is taken, the
program will be aborted if an error occurs.
POST — Create Compressed Communication Byte
This macro, in conjunction with RPOST, is used for
communication between user job steps. POST takes
the first eight bytes located at INFOADR and
interprets each byte to modify the corresponding bit
in a compressed communication byte located in the
Job Control Table*. At the start of a job the POST
communication byte is initialized to zero.
Name Operation Operand
[tag] POST
[ LIST= NES
[ RETURN= \№ 1]
[ ERRCOMP={ No, Hl
INFOADR=symbolic address
Specifies the location of an eight-byte buffer
containing the information to be posted. The buffer
should contain only EBCDIC 0's, 1's or X's. These
bytes will be interpreted as follows to modify the
corresponding eight bits in the communication byte:
EBCDIC O = reset bit to O
EBCDIC 1 = set bit to 1
EBCDIC X = leave bit unchanged
* This scheme is compatible with IBM's UPSI bit mechanism.
7-32
INFOADR=symbolic address
vo | Optional
LisT-{ YE
To be used when either the system linkage (service
request instruction) or the parameter table is to be
generated separately. LIST=NO generates the service
request only; LIST=YES generates the parameter
table (list) only. When no LIST operand is specified,
both the service request and the parameter table are
generated.
ves) Optional
ReTURN- YE
To be used when the user program wishes to be given
control immediately on recognition of the request,
but before completion (RETURN=YES). When
RETURN=NO is coded, or the default is taken,
control will only be returned on completion of the
request.
ER RcoMP=| Optional
YES
NO
To be used when the user decides to retain control in
the event of an error (ERRCOMP=YES). When
ERRCOMP=NO is coded, or the default is taken, the
program will be aborted if an error occurs.
RPOST — Expand from Communication Byte
This macro is used to read information, located in an
interjob step communication area, which was posted
there either by a POST macro in a previous job step
or by the SWITCH=parameter in a //SET Control
Language statement*. Each bit in the one-byte
communication area is expanded to an EBCDIC
equivalent and placed in the buffer specified by
INFOADR.
Name Operation Operand
[tag] RPOST INFOADR=symbolic address
[ LisT={ ES} 1
[ RETURN-| No } ]
[ ERRCOMP= {no a
INFOADR=symbolic address
Specifies the location of an eight-byte buffer where
the interpreted information will be placed. Each bit
in the communication byte will be converted to an
EBCDIC byte as follows:
Binary 0 = EBCDIC O
Binary 1 = EBCDIC 1
Optional
ves)
NO
LisT=|
To be used when either the system linkage (service
request instruction) or the parameter table is to be
generated separately. LIST=NO generates the service
request only; LIST=YES generates the parameter
table (list) only. When no LIST operand is specified,
both the service request and the parameter table are
generated.
Optional
RETURN-| NO)
NO
To be used when the user program wishes to be given
control immediately on recognition of the request,
bubefore completion (RETURN=YES). When
RETURN=NO is coded, or the default is taken,
control will only be returned on completion of the
request.
ves)
ER ACOMP-| NO
Optional
To be used when the user decides to retain control in
the event of an error (ERRCOMP=YES). When
ERRCOMP=NO is coded, or the default is taken, the
program will be aborted if an error occurs.
SETCOM — Transfer to Job Control Table
This macro, in conjunction with GETCOM, is used
for communication between user job steps. It
transfers, without modification, eight bytes of
information located in a user-specified buffer to an
eight-byte communication area in the Job Control
Table where it may be picked up by a GETCOM in a
subsequent job step. At the start of a job the
communication area is initialized to all blanks.
Name Operation Operand
[tag] SETCOM
[те 05 a
[RETUAN=1X0 +)
[ERRCOMP-4 o. |
INFOADR=symbolic address
Specifies the location of an eight-byte buffer
containing the data to be transferred to the
communication area.
INFOADR=symbolic address
Optional
_ [YES
LisT=|NS |
To be used when either the system linkage (service
request instruction) or the parameter table is to be
generated separately. LIST=NO generates the service
request only; LIST=YES generates the parameter
table (list) only. When no LIST operand is specified,
both the service request and the parameter table are
generated.
Optional
RETUAN=I NO)
NO
To be used when the user program wishes to be given
control immediately on recognition of the request
but before completion (RETURN=YES). When
RETURN=NO is coded, or the default is taken,
control will only be returned on completion of the
request.
Optional
ERRCOMP={ NO}
NO
To be used when the user decides to retain control in
the event of an error (ERRCOMP=YES). When
ERRCOMP=NO is coded, or the default is taken, the
program will be aborted if an error occurs.
СЕТСОМ - Transfer from Job Control Table
Communication Area
This macro is used to obtain the information which
had been placed in an eight-byte communication area
by a SETCOM executed in a previous job step. The
content of the communication area, located in the
Job Control Table, is moved, without modification,
to an eight-byte buffer specified by INFOADR.
Name Operation Operand
[tao] GETCOM INFOADR=symbolic address
(List a |
[RETURN=1x5 |]
(ER RCOMP-1 O" }]
INFOADR=symbolic address
Specifies the location of an eight-byte user buffer
into which the contents of the communication area
will be moved.
7-33
Optional
{YES
LisT= [6
To be used when either the system linkage (service
request instruction) or the parameter table is to be
generated separately. LIST=NO generates the service
request only; LIST=YES generates the parameter
table (list) only. When no LIST operand is specified,
both the service request and the parameter tabie are
generated.
Optional
RETURN ol
NO
To be used when the user program wishes to be given
control immediately on recognition of the request,
but before completion (RETURN=YES). When
RETURN=NO is coded, or the default is taken,
control will only be returned on completion of the
request.
YES
ER rcome={ (©
Optional
To be used when the user decides to retain control in
the event of an error (ERRCOMP=YES). When
ERRCOMP=NO is coded, or the default is taken, the
program will be aborted if an error occurs.
ACCEPT — Read //PAR Card
This macro is used to obtain data contained on //PAR
cards supplied in the Control Language deck.
ACCEPT transfers the EBCDIC content of a single
//PAR card to the buffer specified by DATBUF1.
The particular //PAR card read by the ACCEPT is
determined by a pointer located in the Job Control
Table. At the start of the job step, this pointer is
initialized to point to the first //PAR card so that the
first ACCEPT executed in the step will read the first
//PAR card supplied with this step. Each time an
ACCEPT is executed the //PAR card pointer is
updated to the next consecutive card so that on the
next execution the next //PAR card will be read.
If, when an ACCEPT is executed, there are no more
//PAR cards left to be read, control will be
transferred to the location specified by the ENDADR
operand.
The optional operand PARNUM allows the //PAR
pointer to be set to any desired //PAR card by
specifying a user location containing a count (since
the //PAR cards are considered to be numbered 1
through n by implication). Each time an ACCEPT
macro with a PARNUM specification is executed, the
7-34
content of the user counter specified by PARNUM
will be incremented by 1 so that this same ACCEPT
may be re-executed to read the next //PAR card.
The format of the data transferred to the buffer
consists of a four-byte Common Stored Data Format
(CSDF) control header preceding the data from the
//PAR card, unless the optional operand CSD=NO is
included. The content of the //PAR card is always
stripped of characters through the first blank (so as
not to include ‘‘//PAR” itself) and is also stripped of
the sequence number field (columns 73 through 80)
unless the optional operand STRIP=NO is included.
Name Operation Operand
[tag] ACCEPT DATBUF 1=symbolic address
[CSD=NO]
[STRIP=NO]
[PARNUM=symbolic address]
ENDADR=symbolic address
[LisT-( a } ]
[RETURN= NO N
[ERRCOMP=] no 1]
—:—u
DATBUF1=symbolic address
Specifies the location of the buffer into which the
data from the //PAR card will be transferred.
CSD=NO (Optional)
If this operand is used the parameter line will not be
preceded by the CSDF control header.
STRIP=NO (Optional)
If this operand is used the Sequence Number Field
(card columns 73 through 80) will not be stripped.
PARNUM=symbolic address (Optional)
Specifies the location of a one-word binary counter
whose value is to be used as a //PAR card pointer. A
value of 1 will cause the first //PAR card to be read,
and 2 the second, and so on. Each time the ACCEPT
is executed, the value of the counter will be increased
by 1.
ENDADR=symbolic address
This required operand specifies the program address
where control is to be transferred if all the //PAR
cards have been read (value of system's //PAR
counter greater than number of //PAR cards
supplied) or if the PARNUM specified is greater than
the number of //PAR cards supplied.
Optional
LISTO
NO
To be used when either the system linkage (service
request instruction) or the parameter table is to be
generated separately. LIST=NO generates the service
request only; LIST=YES generates the parameter
table (list) only. When no LIST operand is specified,
both the service request and the parameter table are
generated.
RETURN= NO)
NO Optional
To be used when the user program wishes to be given
control immediately on recognition of the request,
but before completion (RETURN=YES). When
RETURN=NO is coded, or the default is taken,
control will only be returned on completion of the
request.
ER всоме-| vo |
NO
To be used when the user decides to retain control in
the event of an error (ERRCOMP=YES). When
ERRCOMP=NO is coded, or the default is taken, the
program will be aborted if an error occurs.
Optional
DISPLAY — Write Message on SY SOUT
The DISPLAY macro is used for writing a one-line
message on the SYSOUT file. The address of the
message buffer, which must be aligned on a word
boundary, is specified by DATBUF. The format of
the buffer must be as follows:
0 Space for CSDF Control Header
(4 bytes)
4 ASA carriage control
character
6 message byte 2
message byte 1
message byte 3
Jl
LC
32
<
message byte n-1 message byte n
The first four bytes of the buffer are reserved for a
Common Stored Data Format (CSDF) control header
to be generated by the system. The fifth byte,
preceding the message, is an ASA carriage control
character” (not to be printed) and the message itself
is an EBCDIC character string up to 132 bytes in
length, starting in the sixth byte. If the message is
shorter than 132 bytes, à storage location containing
the length must be set up and the DATSIZ operand
must be included in the call.
* Details in Control Program and Data Management Services
— Basic Reference,
Name Operation Operand
[tag] DISPLAY DATBUF=symbolic address
[DATSIZ=symbolic address]
_fves
| ERRCONP | NO
DATBUF=symbolic address
Specifies the address of the first byte in the message
buffer. This will be the address of the space reserved
for the CSDF control header and the first byte of the
message itself (the ASA control character) should be
displaced 4 bytes from this address.
DATSIZ=sy mbolic address Optional
Specifies the address of a one-word location
containing the length of the message. If this operand
is omitted, the message length is assumed to be 132
bytes.
Optional
ERRCOMP=[ N}
NO
If ERRCOMP=YES is specified, the program is not
aborted. When ERRCOMP=NO is coded, or the
default is taken, the program will be aborted if an
error occurs.
MEMLIM — Identify Partition Limit
This macro returns the first byte address of the
highest addressable 256-byte page of storage available
to the problem program in the partition in which the
program is running. The returned address is expressed
as the absolute address of the first word of the last
addressable page. MEMLIM is intended for enabling
programs which are expected to run in partitions of
various different sizes to “spread themselves out” to
occupy as much space as is available (in the interest
of efficiency). In this situation, the partition space
pool should always be fixed by means of the
appropriate Linkage Editor directive.”
Name Operation Operand
[tag] MEMLIM INFOADR=symbolic address
[us]
[RETURN-{ 5°} ]
[ERRCOMP= NO a
*Linkage Editor portion of Program Library Services
Reference.
7-35
INFOADR=symbolic address
Specifies the location of a two-byte area where the
address of the highest addressable 256-byte page is to
be placed.
ves)
нет-| NO
Optional
To be used when either the system linkage (service
request instruction) or the parameter table is to be
generated separately. LIST=NO generates the service
request only; LIST=YES generates the parameter
table (list) only. When no LIST operand is specified,
both the service request and the parameter table are
generated.
Optional
_[ YES
RETURN № |
To be used when the user program wishes to be given
control immediately on recognition of the request
but before completion (RETURN=YES). When
RETURN=NO 1$ coded, or the default is taken,
control will only be returned on completion of the
request.
Optional
ER rcomp={ 151
NO
To be used when the user decides to retain control in
the event of an error (ERRCOMP=YES). When
ERRCOMP=NO is coded, or the default is taken, the
program will be aborted if an irrecoverable error
occurs.
SETIF — Post Code for Control Language Test
This macro enables a program, running as one step of
a multi-step job, to post in the Job Control Table
{usually at step completion) a code which may be
tested by a Control Language //1F statement” in
order to govern the subseguent course of the job. The
code to be posted is one byte in length (EBCDIC
character); its address is specified by INFOADR.
Name Operation Operand
[tag] SETIF
[7-5]
[RETURN=1N0
[ERRCOMP=[ NO? |
7-36
INFOADR=symbolic address
INFOADR=symbolic address
Specifies the location of the one-byte (EBCDIC
character) of data to be posted in the IF code field of
the Job Control Table.
Optional
Usr-[E9
NO
To be used when either the system linkage (service
request instruction) or the parameter table is to be
generated separately. LIST=NO generates the service
request only; LIST=YES generates parameter table
(list} only. When no LIST operand is specified, both
the service request and the parameter table are
generated.
Optional
reTuRN-{ (ES)
NO
To be used when the user program wishes to be given
control immediately on recognition of the request
but before completion (RETURN=YES). When
RETURN=NO is coded, or the default is taken,
control will only be returned on completion of the
request.
ER RcoMP=| Optional
YES
NO
To be used when the user decides to retain control in
the event of an error (ERRCOMP=YES). When
ERRCOMP=NO is coded, or the default is taken, the
program will be aborted if an error occurs.
HALT — Terminate Program
The HALT macro is used to perform normal
termination of a user's program step. This macro will
not result in a memory dump unless DUMP=Y ES has
been coded in the //EXECUTE statement associated
with the program. The format for HALT is as
follows:
Name Operation Operand
[tag] HALT
*See Control Language Services Reference.
EHALT — Terminate Program
The EHALT (error halt) macro is used to request
termination of a user's job. This macro will not
automatically give a memory dump unless
DUMP=YES has been coded in the //EXECUTE
statement associated with the program. The format
for EHALT is as follows:
Name Operation Opera nd
[tag] EHALT
ABEND — Terminate Program Abnormally
The ABEND macro is used to request abnormal
termination of a job, and to pass a completion code
to Job Monitor for display. A dump will be given
unless DUMP=NO is specified on the //EXECUTE
statement. The completion code is a 16-bit binary
value. The format for ABEND is as follows:
Na me Operation Opera nd
[tag] ABEND INFOADR=symbolic address
INFOADR=symbolic address
Specifies the first byte address of the area containing
the completion code.
TIME — Retrieve Time of Day
The TIME macro returns the current time of day in
the operand specified. The time of day is returned in
an unpacked decimal format: hhmmss, where hh is
the hour, mm is the minute, and ss is the second. The
format for TIME is as follows:
Name Operation Operand
[tag] TIME INFO ADR=symbolic address
INFOAD R=symbolic address
Specifies the first byte address of the area which
receives the time,
SDATE — Retrieve System Data
The SDATE (system date) macro returns the system
data in the operand specified. The date is returned in
one of two unpacked decimal formats: mmddyy or
vyiij, where mm is the month, dd is the day, yy is the
year, and jjj is the Julian day. The format for SDATE
is as follows:
Name Operation Operand
tag SDATE INFOADR=symbotic address
MODE= {=}
INFOAD R=symbolic address
Specifies the first byte address of the area that
receives the data.
_JC
wooe- {2}
Specifies the current date in the calendar (C) 6-byte
format mmddyy or the Julian (U) 5-byte format
vyiij. The default value is C.
JDATE — Retrieve Job Date
The JDATE (job date) macro returns the date
provided for by a //SET statement. The date returned
will be the system date unless the //SET statement
has specified a job date. The date is returned in one
of two unpacked decimal formats: mmddyy or YYili,
where mm is the month, dd is the day, yy is the year,
and jjj is the Julian day. The format for JDATE is as
follows:
Name Operation Operand
tag JDÂTE INFOADR=symbolic address
MODE= (=)
INFOADR=symbolic address
Specifies the first byte address of the area which
receives the date.
море- 5
J
Specifies the current date in the calendar (C) 6-byte
format mmddyy or Julian (J) 5-bit format yyijj. The
default value is C.
CONSOLE COMMUNICATION MACROS
Two macros, CONSOLE (an active macro) and
MESSAGE (a data macro), are available for
communicating with the operator's console.
7-37
CONSOLE — Transmit Message to Console and
Optionally Receive Reply
The: CONSOLE macro enables programs to transmit
messages to the operator's console and optionally
receive replies. The main-storage format of the
message to be sent to the console must include two
fields, a control block which is not typed and the text
field which contains the actual message. The buffer
set up to receive a reply from the console {if any)
must contain a control block followed by the actual
buffer for the reply text. The format of CONSOLE is
as follows:
Name Operation Operand
[tag] CONSOLE DATBUF1=symbolic
address
[DATBUF2=symbolic
address]
DATBUF 1=symbolic address
Specifies the address of the message control block
which is followed by the message test.
DATBUF2=symbolic address (Optional)
Specifies the address of the reply control block which
is followed by the reply buffer area.
MESSAGE — Set Up Message Format
The MESSAGE macro, to be used in conjunction
with the CONSOLE macro, simplifies the generation
of messages by creating the correct format required
by CONSOLE. A tag is required for all MESSAGE
macros so that the corresponding CONSOLE macro
may locate it. Two formats exist for the MESSAGE
macro, one for generating an output message and one
for generating a reply buffer.
Generation of an Output Message
The format for generating an output message is as
follows:
Name Operation Operand
tag MESSAGE [DATBUF1=symbolic address]
DATSIZ1=decimail number
DATATXT=character string
| мос E=| +1]
7-38
DATBUF 1=symbolic address (Optional)
Enables a name to be attached to the beginning of the
message text field.
DATSIZ1=decimal number
Specifies the decimal length (in bytes) of the message
text. If no length is specified, the text length will be
used. If there is no message, a length of zero is
assumed. The maximum value of DATSIZ1 is 100.
DATATXT=character string
Specifies the actual message to be placed in the
message text field. It is created in EBCDIC and may
be up to 100 characters (bytes) long. The default is a
string af blanks, with length being determined by the
parameter DATSIZ1. The character string must be
coded in the form, C'message text’.
MODE= |5 (Optional)
Specifies whether the message is informative (I) or
directive (D). MODE=D indicates that the message
calls for some operator action. The default value of
MODE is |.
Generation of a Reply Buffer
The format for generating a reply buffer is as follows:
Name Operation Operand
tag MESSAGE [DATBUF2=symbolic address]
DATSIZ2=decimal number
DATBUF2=symbolic address (Optional)
Enables a name to be attached to the beginning of the
reply text field. |
DATSIZ?2=decimal number
Specifies the decimal length in characters (bytes) of
the reply buffer to be generated. The reply field will
be assembled with blanks. The maximum value of
DATSIZ2 is 100.
A. PACK CATALOG AND CENTRAL
CATALOG FORMATS
The formats used by the pack catalog and central
catalog of the disc are discussed in the following
paragraphs.
PACK CATALOG
Figures A-1 through A-5 illustrate the use of the
name, attribute and space elements in generating the
pack catalog. The normal block of the pack catalog is
128 bytes, and the continuation element is 64 bytes
for normal files and 128 bytes for a continuation to
the description of pack space, which is catalog blocks.
At disc initialization time, the pack catalog is created
with block formatting as follows (assuming the pack
contains the central catalog):
Block 1 Entry that describes the pack
catalog itself
Block 2 Entry that describes the space
available on the pack
Block 3 Entry that describes the space
occupied by the central catalog
Block 4 First block of space available in
the pack catalog. Name element
fields are filled as follows:
Control bytes X‘8200007C"
X000500'
Previous name XX"000000'
Next name
Biock 5-n Remaining blocks of space are
constructed in the same format as
block 4 with proper linking
through the next name and
previous name fields.
During the process of allocating a data file, one of the
available blocks is removed from the string of
available pack catalog blocks and is linked into the
chain describing existing files. When space is needed
for a continuation element, another block is removed
from the available chain. Half of the block is used for
a continuation element and the other half is linked to
start the chain of available continuation space.
CENTRAL CATALOG
Figures A-6 through A-8 illustrate the use of the
name, attribute, and volume elements in constructing
entries for the central catalog. The normal block size
of the central catalog is 128 bytes, and the
continuation element is 64 bytes.
At disc initialization time, the first block is formatted
as shown in Figure A-7. Remaining blocks are
considered available and are linked as those in the
pack catalog.
A-1
33
127
CONTROL BYTES FOR NAME EL EMENT
FILE NAME: X'00014B'
POINTERS TO ATTRIBUTE ELEMENT, SPACE
ELEMENT AND AVAILABLE PACK CATALOG
BLOCKS, AVAILABLE PACK CATALOG
CONTINUATION ELEMENTS
CONTROL BYTES FOR ATTRIBUTE ELEMENT
CONTROL BYTES FOR SPACE ELEMENT
7 SEGMENTS WITH
UNUSED BYTES
AT THE END
Figure A-1. Block 1 — Pack Catalog Entry in Pack Catalog
NAME
ELEMENT
ATTRIBUTE
ELEMENT
SPACE
ELEMENT
127
CONTROL BYTES FOR NAME ELEMENT
FILE NAME: X'00024B'
POINTERS TO SPACE ELEMENT
CONTROL BYTES FOR SPACE ELEMENT
14 SEGMENTS WITH
UNUSED BYTES
AT THE END
Figure A-2. Block 2 — Space Entry in Pack Catalog
NAME
ELEMENT
SPACE
ELEMENT
0
CONTROL BYTES FOR NAME ELEMENT
NAME
FILE NAME: X'000348' ELEMENT
POINTERS TO ATTRIBUTE ELEMENT
AND SPACE ELEMENT
25
26
CONTROL BYTES FOR ATTRIBUTE ELEMENT
ATTRIBUTE
ELEMENT
55
56
CONTROL BYTES FOR SPACE ELEMENT
8 SEGMENTS WITH
UNUSED BYTES SPACE
AT THE END ELEMENT
127
Figure A-3. Block 3 — Central Catalog Entry in Pack Catalog
A-4
49
50
79
127
CONTROL BYTES FOR NAME ELEMENT
NAME
ELEMENT
POINTERS TO ATTRIBUTE ELEMENT,
SPACE ELEMENT, AND
ASSOCIATED NAME ELEMENT
CONTROL BYTES FOR ATTRIBUTE ELEMENT
ATTRIBUTE
ELEMENT
CONTROL BYTES FOR SPACE ELEMENT
4 SEGMENTS WITH SPACE
UNUSED BYTES ELEMENT
AT THE END
Figure A-4. Block 4-n — Normal File Entry in Pack Catalog
A-6
63
CONTROL BYTES FOR SPACE CONTINUATION
Figure A-5. Pack Catalog Space Element Continuation
127
CONTROL BYTES FOR NAME ELEMENT
FILE МАМЕ: Х’00014В'
POINTERS TO ATTRIBUTE ELEMENT, VOLUME
ELEMENT, AVAILABLE CENTRAL CATALOG
BLOCKS, AND AVAILABLE CENTRAL CATALOG
CONTINUATION ELEMENTS
CONTROL BYTES FOR ATTRIBUTE ELEMENT
CONTROL BYTES FOR VOLUME ELEMENT
4 VOLUMES
Figure A-6. Block 1 — Central Catalog Entry in Central Catalog
NAME
ELEMENT
ATTRIBUTE
ELEMENT
VOLUME
ELEMENT
A-7
49
50
79
80
127
A-8
CONTROL BYTES FOR NAME ELEMENT
NAME
ELEMENT
POINTERS TO ATTRIBUTE ELEMENT,
VOLUME ELEMENT, AND
ASSOCIATED NAME ELEMENT
CONTROL BYTES FOR ATTRIBUTE ELEMENT
ATTRIBUTE
ELEMENT
CONTROL BYTES FOR VOLUME ELEMENT
3 VOLUMES VOLUME
ELEMENT
Figure A-7. Block 2-n — Normal File Entry in Central Catalog
63
CONTROL BYTES FOR VOLUME CONTINUATION
Figure A-8. Central Catalog Volume Element Continuation
B. SERVICE REQUEST MECHANISM
AND MACRO EXPANSIONS
INTRODUCTION
There are essentially two types of system macro
instructions: action macros and data macros. Action
macros, which expand into executable code, may be
further subdivided into user code macros and service
request macros. User code macros expand into code
which is primarily executed within the user's program
(except for possible nested service request macros).
Service request macros, on the other hand, link to
— system routines for their implementation.
Examples:
GET, DISPLAY user code macros
READ, GETCOM service request macros
MESSAGE, COMMAND data macros
Most of the control program and block input/output
macros are service request macros whereas most of
the physical input/output macros are data macros.
- The expansions of all service request macros contain a
service request machine instruction.
SERVICE REQUEST INSTRUCTION
The Service Request instruction (mnemonic SR) is
the only means by which a user program* may
communicate with the operating system. In practice,
however, there is no need for the user to code this
instruction directly, since it will automatically be
*This same method is also often employed by system
programs to communicate with each other.
generated in the expansion of a service request macro
instruction. Figure B-1 illustrates the control path
between a user program and operating system.
SERVICE REQUEST MACRO EXPANSION
CONVENTIONS
The expansions of all* service request macros will
normally begin with the following standard three
words (with no LIST operand used):
Byte Byte
о 10 a?
0 Service Request Instruction
2 Function Code Length
4 Return Information
Any additional words in the expansion are uniquely
defined for each macro,
SERVICE REQUEST INSTRUCTION (BYTES O
AND 1)
This instruction establishes the link with the
operating system; it is defined as follows.
* Except for the physical input/output macro, EXCP.
USER
PROGRAM
SYSTEM
OPERATING
SYSTEM
CONTROL PROGRAM
RETURN
SERVICE REQUEST
PARAMETERS
B-2
Figure B-1. Service Request Linkage to System
SERVICE
PROGRAM
Byte 0 Byte 1
0 7 0 1 2 3 4 7
Service Request | A Request
Function Code Class
Service Request Function Code: SR = X'13'
I: parameter list location indicator
0 immediately following this instruction
1 at location whose address is contained in
register 6
R: Return indicator
O return control only after request is completed
1 return control immediately after request is
accepted
EP: User error processing indicator
O user program to be aborted on occurrence of
an error
1 user to retain control after an error
Request Class: Major class of service request
0 = Debug Request (system only)
-
||
Restricted Request (system only)
= Control Program Request
= Block Input/Output Request
lilegal
= Supervisor Request
= Telecommunications Request
~N с с в с
Il
= Physical Input/Output Request
FUNCTION CODE (BYTE 2)
Function or operation code for this request (see
individual expansions).
LENGTH (BYTE 3)
Number of words in this request block, excluding the
service request instruction (see individual
expansions).
RETURN INFORMATION (BYTES 4 AND 5)
This word is an area where the system will return
information developed during the execution of the
request. On initial receipt of the request the whole
word will be set to zero. The return information field
is defined as follows:
Byte 4 Byte 5
er ts UE Re EA
01 2 3 7 0 7
C | EJEND Not Used Return Code
Complete Bit (C)
This bit will be set by the system to indicate that the
request has been completed (normally or otherwise).
Error Flag (E)
When this bit is set an abnormal completion is
indicated in which case the remainder of the word
will contain information connected with the error. If
the error flag is not set, no further information will
be contained in this word (except in the case of
END). This bit may be set on completion even if the
EP bit is not set in the SR.
End Flag (END)
When set, this bit indicates that one of a number of
possible end conditions has been detected. The
particular end condition is specified by the return
code in byte b, as follows:
00 = Disc EOA (end of allocation)
01 = Printer Channel 12
02 = Disc EOF (end of file)
03 = Card Reader EOF
04 = Printer Channel 9
05 = Printer Channels 9 and 12
Return Code
This eight-bit code contains specific information
about the error (return code, Table C-1, Appendix C).
OPTIONAL PARAMETERS
Three keyword parameters are usable by most block
1/0 level service request macros: RETURN,
ERRCOMP, and LIST. The LIST parameter gives the
option of separating the parameter packet and service
request instruction, or not doing so.
If LIST=YES, the RETURN and ERRCOMP
parameters cannot be used; if LIST=NO, the
RETURN and ERRCOMP parameters are the only
other parameters which can be used. However, if
LIST is omitted, these two parameters can be used
independently.
LIST
If LIST=YES, only the appropriate parameter packet
is generated. The LIST=YES option allows the
generation of the macro parameter packet only once
in the program.
B-3
If LIST=NO, only a 2-byte standard service request
instruction is generated. The user must load into
general-purpose register 6 (R6) the address of the
parameter packet to be referenced and into register 7
(R7) the address of the save area address prior to
issuing the LIST=NO option.
The 2-byte service request instruction has the
following format, where 05 defines the Data
Management expansions and 13 the function code.
13 05
Example:
OFERATION OPERAND
Ce Na Te, EZ
+ + a A E . ,
dE.
a AA AAA AA 1
TA RNE YES
e nn - 16 AAA 6... - +
L E. a A AL a 1 A a.
a
+2 E...
TYPE BE к...
BSR a
a dt 44 €
With the LODD instruction, the user loads into R6
the address of a parameter packet which has been
specified elsewhere in the program (ТАС 5), and the
save area address (SA VEIT) into R7.
With the OPEN macro and a LIST=NO parameter
specified, only the 2-byte executive request code is
generated.
At TAG 5, the OPEN parameter list is generated.
If the LIST option is omitted, the service request
instruction is generated followed by the appropriate
parameter list. The user must load the address of the
save area into R7 prior to issuing the call.
13 05
OPEN
Parameter
Packet
OPERATION
15
AA Aa
А. OA AAA AA AA ALA AA a
eam A aaa aE aaa da + 4 + A a
The LIST default for the OPEN request results in the
generation of the service request instruction followed
by the OPEN parameter packet.
RETURN
The RETURN parameter enables the user to request
that control be returned to his program immediately
after the service request has been received and
recognized by the system (but before the function it
requests has been completed). By coding
RETURN=YES, the user may save time by
proceeding with his own processing while the system
is processing the service request. When
RETURN=YES is used, detection of request
completion becomes a user responsibility (he must
check the complete bit in the return information
word of the request parameter list). The RETURN
parameter is mostly applicable to input/output
service requests, which are relatively slow to
complete. The default specification, RETURN=NO
may be coded explicitly if desired. (Note that there
are certain service request macros on which the
RETURN parameter is not available.)
ERRCOMP
The ERRCOMP parameter allows the user to retain
control when an error occurs which the system was
unable to correct. By coding ERRCOMP=YES the
user has the option of attempting to correct any
errors or of simply ignoring* them and continuing.
The default condition ERRCOMP=NO, which may be
coded explicitly if desired, results in a program abort
in the event of an error (which the system was unable
to correct).
STANDARD SYSTEM SUFFIXES
If the programmer wishes to reference a particular
word of a parameter packet, he may do so by adding
the standard system suffix to his tag name (name
symbol). If the tag name is six characters or less, the
standard suffix is appended to the tag name. If the
tag name is seven or eight characters, this (these) last
character(s) is (are) truncated and the standard suffix
is appended. For this reason the first six characters
must be unique. The standard suffixes are listed
alongside the macro expansion with the suffix across
from the appropriate parameter packet word.
* Occasionally, a condition may arise which is classified by
the system as an error but which does not affect the
outcome of the user program.
For an example: if the programmer wishes to
reference the word containing the file type of the
ALLOC macro, it is located in byte 5 which is
referenced by the F1 suffix. If his tag name is JOB65,
the word may be referenced with JOB65F1.
However, if his tag name is MYJOB658, the reference
is MYJOB6F1.
EXPANSION TABLES
The expansion of each macro is detailed in the
following pages; generally there is a map of the bytes
as stored, followed by detailed assignments of bytes
and bits.
The macros are listed in these groupings:
e Data Management
ALLOCATE
EXPAND
PURGE
OPEN
CLOSE
CLOVE
LABRTN
e Block 1/0
STATUS/TYPE
CONTRL/POSITN
READ/WRITE
RESET
° Physical 1/0
EXCP
PCB
COMMAND (various applications)
e Control Program
WAIT
POST/RPOST
SETCOM/GETCOM
ACCEPT
DISPLAY
MEMLIM
INFORM
SETIF
DELAY
HALT
EHALT
ABEND
TIME
SDATE
JDATE
e Console Communications
CONSOLE
“These expansion explanations show the parameter
tables or lists without the service request instruction
(for those macros including a service request). Byte
displacement shown at the side of the tables is
without the service request; considering the service
request, it is necessary to increase the displacement
count by 2.
Where applicable, bytes containing Segment Tags are
shown. This tag is mandatory in systems having more
than 64K bytes of storage, and may be implemented
in smaller systems. A programmer should be aware
that the showing of Segment Tags in these format
drawings does not necessarily imply that the tags will
be in the system he is using.
B-5
Table B-1. ALLOCATE Parameter Packet Format
Suffixtt
0 Request Code Length FL
21 C Return Information Return Code CR
af PF | UC| ES | CB | МУ | со Е ß FT F1
6 1 1 1 1 L1 L1 L2 L2 iA IA IB IK DC IC F3
8
Data Block Count BC
10
12 Data Block Size BS
14 Data Record Size RS
16 | S TAG LAB1
18 LAB1 ADR L1
20 S TAG LAB2
22 LAB2 ADR L2
24 S TAG IDENT
t 26 IDENT ADR IA
28 Index Block Size 18
30 Index Key Size IK
32 Data Cylinder Number DC
34 index Cylinder Number IC
36 Spread Factor SF
Byte Bit Description
0 Request code, 1 designates ALLOCATE.
1 Length, number of words in the parameter packet (10 to 19 words)
2 0 Request complete indicator (C)
0 Service request in process
1 Request complete
1-7 Return information
3 Return code
4 0 Paired file (PF). PF=1 for paired file.
+ Bytes 6 and 7 reflect which optional parameters are present. If a parameter is not present, as evidenced by the presence of a
zero in that parameter bit, the corresponding 2-byte word in bytes 16 through 37 is omitted, and those parameters that follow
are telescoped upward by one word. Four-byte parameters such as IDENT ADR with its segment tag and reserved byte, is
represented by two bits in the pattern. Both bits (IA) must be set if IDENT ADR is present.
tt The 2-character suffix for unique file identifier.
B-6
Table B-1. ALLOCATE Parameter Packet Format (Continued)
Byte Bit Description
1 Uncataloged (UC). UC=1 for not recording file in the central catalog.
2 Contiguous space (CS). CS=1 for contiguous space on each volume,
3 Cylinder boundary (CB). CB=1 for space segments starting on cylinder boundary,
4 Write verify (WV). WV=1 for write verification of files..
5 Common stored data format (CD). CD=1 for common stored data format.
5 3,4 File type (FT)
00 Permanent
01 Scratch
10 Temporary
11 Work
5-7 File organization (FO)
000 General
001 indexed
010 Relative
100 Sequential
6 4,5 LAB1 ADR specified (L1=1)t
6,7 LAB2 ADR specified (L2=1}t
7 0,1 IDENT ADR specified (1A=1)t
2 Index block size specified (IB=1)
3 Index key size specified (1K=1)
4 Data cylinder number specified (DC=1)
5 Index cylinder number specified (IC=1)
6 Spread factor specified (SF=1)
8-11 Data block count, number of blocks for data file
12,13 Data block size, size (in bytes) of data block
14,15 Data record size, size (in bytes) of record
17* Segment tag for LAB1 ADR (S TAG LAB1)
18,19* LAB1 ADR, address of label information for the primary data file LABDEF1 , reguired if IDENT ADR is not
specified.
*Optional parameter.
TTwo fields are shown on format expansion to accommodate paired files.
B-7
Table B-1. ALLOCATE Parameter Packet [Format (Continued)
Byte Bit Description
21* Segment tag for LAB2 ADR (S TAG LAB2)
22,23* LAB2 ADR, address of label information for a paired file LABDEF2.
25* Segment tag for IDENT ADR (S TAG IDENT)
26,27* IDENT ADR, address of file identifier as used by Control Language to identify volumes for use in allocation
28,29* Index block size, size (in bytes) of index file
| 30,31* index key size, size (in bytes) af key
32,33* Data cylinder number, cylinder number at which allocation of the data file starts
34,35* Index cylinder number, cylinder number at which allocation of index file starts
36,37* Spread factor, physical record interlace to be used in an indexed data file
*Optional parameter
B-8
Table B-2. EXPAND Parameter Packet Format | Suffixtt
0 Request Code Length FL
2] C Return Information о Return Code CR
4| РЕ | UC 1 | L1| LI | LA F1
6 Data Block Count - | BC
8 тит
10 : S TAG LAB1
12 LAB1 ADR L1
' 141 S TAG IDENT
16 IDENT ADR IA
Byte Bit Description
0 Request code, 2 designates EXPND
1 Length, number of words in parameter packet (7 to 9 words)
2 0 Request complete indicator (C)
0 Service request in process
1 Request complete
1-7 Return information
3 0-7 Return code
4 0 Paired file (PF), PF=1 for paired file
1 Uncataloged (UC), UC=1 for uncataloged file
2 Contiguous Space (CS), CS=1 if space on each volume is to remain contiguous.
5 2,3 LAB1 ADR specified (L1=1)t
4,5 IDENT ADR specified (1A=1)+
6-8 Data block count, number of data blocks to add to the file
t Byte 5 reflects which optional parameters are present. If a parameter is not present, the corresponding 4-byte field in bytes 10
through 17 is deleted from the parameter packet and the subsequent parameter words are moved upward. The 4-byte field is
represented by two bits in byte 5; both bits must be set (or cleared) to reflect the presence of the field.
tt The 2-character suffix for unique file identifier.
B-9
Table B-2. EXPAND Parameter Packet Format (Continued)
Byte Bit Description
11* Segment tag for LAB1 ADR (S TAG LAB1)
12,13* LAB1 ADR, address of label information for the file. This parameter is required if IDENT ADR is not specified.
15* Segment tag for IDENT ADR (S TAG IDENT)
16,17*
IDENT ADR, address of file identifier as used by Control Language. This parameter is required if the file is open
at the time of expansion.
*Optional parameter
B-10
Table B-3. PURGE Parameter Packet Format Suffixtt
0 Request Code Length : FL
C Return Information Return Code CR
4 ; { L1 L1 IA
6 S TAG LAB1
+ 8 i LAB1 ADR L1
10 | S TAG IDENT
121 IDENT ADR IA
Byte Bits Description
0 Request code, 3 designates PURGE
1 Length, number of words in parameter packet (5 to 7 words)
2 0 Request complete indicator (C)
0 Service request in process
1 Request complete
1-7 Return information
3 “Return code
4 0 Paired file (PF), PF=1 for paired files
1 Uncataloged (UC), UC=1 for uncataloged file
5 0,1 LAB1 ADR specified (L1=1)
2,3 IDENT ADR specified (1A=1)
7* Segment tag for LAB1 ADR (S TAG LAB1)
8,9* LAB1 ADR, address of label information for data file. This parameter is required if IDENT ADR is not specified.
11* Segment tag for IDENT ADR
12,13* IDENT ADR, address of file identifier as used by Control Language
t Byte 5 reflects which optional parameters are present. If a parameter is not present, the corresponding 4-byte field in bytes 6
through 13 is deleted from the parameter packet and the subsequent parameter words are moved upward. The 4-byte field is
represented by two bits in byte 5. Both bits must be set to reflect the presence of the field.
* Optional parameter.
tt The 2-character suffix for unique file identifier.
Table B-4. OPEN Parameter Packet Format : Suffixtt
Request Code Length FL
Return Information Return Code CR
T U R L S TAG IDENT BT
BDT or IDENT ID
S TAG LAB ADR
LAB ADR LS
S TAG BUF ADR
BUF ADR BF
Byte Bit Description
0 Request code, 4 designates OPEN
1 Length, number of words in parameter packet (4 to 8 words)
2 0 Request completion indicator (C)
0 Service request in process
1 Request complete
1-7 Return information
3 0-7 Return code
4 0 Control character (CC)
0 ANSI control characters
1 Device control characters
1 Buffer address (BA)
0 No buffer
1 Buffer present
2-3 Type of 1/0 (T)
00 Logical
01 Block
10 Physical
T Byte 4 reflects which optional parameters are present. If a parameter is not present, the corresponding 2-byte word in bytes 8
through 15 is deleted from the parameter packet and the subsequent parameter words are moved.
tT The 2-character suffix for unique file identifier.
Table B-4. OPEN Parameter Packet Format (Continued)
Byte Bit Description
4-5 Usage (U)
00 Input
01 Update
10 Output
6 Rewind (R)
о No rewind
1 Rewind
7 Label {L)
0 No label
1 Label address
5 ~ Segment tag for BDT or IDENT (S TAG IDENT)
6,7 BDT or IDENT, address of BDT or address of file identifier
9* Segment tag for LAB ADR (S TAG LAB ADR)
10,11* LAB ADR, label address
13* Segment tag for BUF ADR (S TAG BUF ADR)
14,15* BUF ADR, buffer address
*Optional parameter.
Table B-5. CLOSE Parameter Packet Format
Request Code Length
Return Information Return Code
L
R S TAG IDENT
Suffixt
BDT or IDENT
Byte Bit Description
0 Request code, 5 designates CLOSE
1 Length, number of words in parameter packet (4 words)
2 0 Request complete indicator (C)
0 Service request in process
1 Request complete
1-7 Return information
3 Return code
4 2 Lock (L)
0 No lock
1 Lock
34 Type of 1/0 (T)
00 Logical 1/0
01 Block 1/0
10 Physical 1/0
6 Rewind (R)
0 No rewind
1 Rewind
5 Segment tag for IDENT or BDT (S TAG IDENT)
6,7 BDT or IDENT, address of BDT or address of file identifier
+The 2-character suffix for unique file identifier.
Table B-6. CLOVE Parameter Packet Format Suffix t
Request Code FL
Return Information Return Code CR
T S TAG IDENT
BDT or IDENT ID
Byte Bit Description
0 Request code, 6 designates CLOVE
1 Length, number of words in parameter packet (4 words)
2 0 Request complete indicator (C)
О Service request in process
1 Request complete
1-7 Return information
3 Return code
4 3,4 Type of 1/0 (T)
00 Logical 1/0
01 Block 1/0
5 Segment tag for BDT or IDENT (S TAG IDENT)
6,7 BDT or IDENT, address of BDT or address of file identifier
tThe 2-character suffix for unique file identifier.
B-15
Table B-7. LABRTN Parameter Packet Forrnat
Request Code Length
Return Information Return Code
S TAG IDENT
IDENT ADR
S TAG BUFF
BUFF ADDRESS
Byte Bit Description
0 Request code, 7 designates LABRTN
1 Length, number of words in parameter packet (6 words)
2 0 Request completion indicator (C)
0 Service request in process
1 Request complete
1-7 Return information
3 Return code
4 5-7 Element field (ELEM)
000 Name element returned
001 Attribute element returned
010 Both elements returned
5 Segment tag far IDENT (S TAG IDENT)
6,7 IDENT ADR, address of file identifier
9 Segment tag for buffer address (S TAG BUFF)
10,11 Address of buffer containing status information
+The 2-character suffix for unique file identifier.
B-16
Suffixt
FL
CR
BT
Table B-8. STATUS and TYPE Macros Parameter Packet Format
Request Code Length
Return Information
Pointer to File Identifier
Buffer Address
Pointer to Byte Counter
Suffix *
FL
CR
BA
BS
Byte Bit Description
О 0-7 Request Code: STATUS=40, TYPE=41)
1 0-7 Length, number of words in parameter: 08
2,3 0-15 | Return Information
4 0-7 Not used
5 0-7 Segment Tag
6, 7 0-7 Pointer to file ID: Address of 8-byte file identifier
8 0-7 Not used
9 0-7 Segment Tag
10, 11 0-7 Buffer Address: first byte address of user-specified buffer area
12 0-7 Not used
13 0-7 Segment Tag
14,15 0-7 Pointer to Byte Count: address of 2-byte area containing byte count (length of buffer) |
*The 2-character suffix for the unique file identifier.
B-17
Table B-9. CNTRL/POSITN Macros Parameter Packet Format
Request Code Length
Return Information
Sub-Function Code
Pointer to File 1D
Pointer to Block Number
Residual Byte Count
Suffix*
Byte Bit Description
0 0-7 Request Code: CNTR L=03,POSITN=04
1 0-7 Length, number of words in the parameter packet, 07
3 0-7 Return Information
4 0-7 Sub-Function Code (the indicated bits are set for the function):
7 Select Stacker |
6 Space Line Printer
5 Skip Line Printer Form
0-2 Rewind (000)
Rewind and Unload (001)
Erase gap (010)
Backspace Record (100)
Forward space a record (110)
Forward space a file (111)
Backspace a file (101)
Write End-of-File mark (011)
0-3 The value of nn when SS, SK, or SP is used
7 Beginning of volume
6 End of Volume
0 SEEK on position
5 0-7 Segment Tag
6,7 0-7 Pointer to File ID: address of 8-byte file identifier in FDT
0-7
8 0-7 Not used
9 0-7 Segment Tag
10,11 0-7 Pointer to Block No.: address of 4-byte block number (applies to POSITN)
0-7
12,13 0-7 Residual Byte Count: difference between number of bytes requested and number of bytes received.
0-7
*The 2-character suffix for unique file identifier.
B-18
- Table B-10. READ/WRITE Macros Parameter Packet Format
Request Code Length
Return Information
Sub-Function Code
Pointer to File ID
Pointer to Block Number
Residual Byte Count
Buffer Address
Pointer to Byte Count
Suffix*
FL
CR
SF
BN
RC
BA
BS
Byte Bit Description
0 0-7 Function Code: READ=02, WRITE=01
1 07 Length, number of words in the parameter packet: 11
2,3 0-7 Return Information
0-7
4 0-7 Sub-Function Code (the indicated bits are set for the function):
7 Select Stacker
6 Space Line Printer
5 Skip Line Printer Form
4 EBCDIC=NO
0-3 The value of nn when SK or SP is used
0-2 The value of nn when SS is used
5 0-7 Segment Tag
6,7 0-7 Pointer to File ID: address of 8-byte file identifier
0-7 `
8 0-7 Not used
9 0-7 Segment Tag
10,11 0-7 Pointer to Block No.: address of 4-byte area containing block number
0-7
12,13 0-7 Residual Byte Count: difference between number of requested bytes and number of bytes transferred
0-7
14 0-7 Not used
15 0-7 Segment Tag
*The 2-character suffix for unique file identifier.
B-19
Table B-10. READ/WRITE Macros Parameter Packet Format (Continued)
Byte Bit Description
16,17 0-7 Buffer Address: first byte address of user specified buffer area
0-7
18 0-7 Not used
19 0-7 Segment Tag
20,21 0-7 Pointer to Byte Count: address of 2-byte area containing the byte count (length of buffer)
0-7
Table B-11. RESET Macro Parameter Packet Format
Request Code
Return Information
Pointer to File ID
Suffix*
Byte Bit Description
0 0-7 Function Code: RESET=31
1 0-7 Length, number of words in the parameter packet: 04
2,3 0-7 Return information
4 0-7 Not used
5 0-7 Segment Tag
6, 7 0-7 Pointer to File ID: address of 8-byte file identifier
*The 2-character suffix for unique file identifier.
B-20
Table B-12. EXCP Macro Expansion
The expansion of the EXCP macro does not include a parameter table (LIST=NO is implied) but it may, depending
on the operands coded in the call, contain executable code for request setup purposes:
No operands: SR
PCB=@register number: ~~ MOVR | Rn,6
SR
PCB=sy mbolic address: LOD symbolic address,6
SR
CP=QCregister number: STO 6(6),Rn
SR
CP=symbolic address: MOVM symbolic address, 6(6)
SR
UNORD=symbolic address: | MOVB symbolic address, O(6)
SR
UNORD=@register number! STOB 0(6),Rn
SR
B-21
Table B-13. PCB Macro Parameter Packet Format
0* Unit Ordinal Length
2 Return Informatio
a x
6 Pointer to CP or FC
8 Pointer to Current CW
10 Status
12 Residual Byte Count
14 Sense
Lo III --—-— -
16 | Sense |
a E o
*This macro does not use the standard service request prefix.
Byte Bit Description
0 0-7 Unit Ordinal: Device identifier
1 0-7 Length, number of words in this block excluding Device Ident field
2,3 0-7 Return Information (same as for service request macros)
0-7
4 0 Error Recovery Flag (ERP)
O = Call system error recovery when an error occurs
1 = Bypass error recovery
1 Not used
2 Command Program Flag
0 = Next word is address of command program to be executed
1 = Next word is function code to be executed
3-7 Not used
5 0-7 Not used
6,7 0-7 Pointer to CP or FC
0-7 If CP=0, pointer to command program
If CP=1, pointer to function code
8,9 0-7 Pointer to Current CW: Address of command word being executed
0-7
10,11 0-7 Status indication
0-7
B-22
Table B-13. PCB Macro Parameter Packet Format (Continued)
Byte Bit Description
12,13 0-7 Residual Byte Count: difference between number of bytes requested and number of bytes transferred
0-7 о
14,15, Sense bytes: variable number of sense bytes depending on device
16,17, Disc = none
18,19
Unit Record = 2
Mag Tape = 6
SL
Table B-14. COMMAND Macro Parameter Packet Format (Basic Data Channel)
SK
Command Code
Byte Count
STAG
Buffer Address
*This macro does not use the standard service request prefix.
Byte Bit Description
0 0 Chain Flag (C)
0 = No CW follows this one
1 = Another CW follows
1 Suppress Length Check (SL): if it is set, the CP will not be terminated when the transferred
byte count differs from the specified byte count. Not used when C= 0,
2 Skip (SK): If it is set, data will not be transferred to memory on a data input operation.
3-7 Not used
8-15 Command Code: The eight-bit hardware command code (OPCODE).
2,3 0-7 Byte Count: The length of the data buffer (BUFSIZ) in hexadecimal; length must be non-zero
4 0-7 Not used
5 0-7 Segment Tag
6,7 0-7
Buffer Address: the FBA address of the data buffer (BUFADR).
B-23
Table B-15. COMMAND Macro Parameter Packet Format (DCABLE)
Buffer Address
*This macro does not use the standard service request prefix.
Byte Bit Description
0 0 Chain Flag
0 = No CW follows this one
1 = Another CW follows
1-7 Not used
1 0-7 Command Code: DCABLE=21
2,3 0-7 Byte Count: DCABLE=0002
4 0-7 Not used
5 0-7 Segment Tag
6, 7 0-7 Buffer Address: address of buffer into which the disc drive cable address is to be transferred.
B-24
Table B-16. COMMAND Macro Parameter Packet Format (DCSEEK)
Buffer Address
* This macro does not use the standard service request prefix.
Byte Bit Description
0 0 Chain Flag
О = No CW follows this one
1 = Another CW follows
1-7 Not used
1 0-7 Command Code: DCSEEK=20
2,3 0-7 Byte Count: DCSEEK=0004
4 0-7 Not used
b 0-7 Segment Tag
6, 7 0-7 Buffer Address: address of buffer containing cylinder and track numbers,
B-25
Table B-17. COMMAND Macro Parameter Packet Format (DCSRCH)
Byte Count
Buffer Address
*This macro does not use the standard service request prefix.
Byte Bit Description
0 о Chain Flag
0 = No CW follows this one
1 = Another CW follows
1-3 Bit Ring Sync: least-significant three bits of Bit Ring Sync Code
101 = home address field
011 = RO count field
110 = RN count field
1 0-7 Command Code: DCSRCH=08
2,3 0-7 Byte Count: Length of field for which search is being made
BC = 0005 for home address
BC = 0009 for count field
4 0-7 Not used
5 0-7 Segment Tag
6, 7 Buffer Address: address of buffer containing field data for which search is being made
B-26
Table B-18. COMMAND Macro Parameter Packet Format (DCREAD)
(1) Read with Transfer
O*
С
BRS
Single Record Byte Count
STAG
Buffer Address
Overall Byte Count |
*This macro does not use the standard service request prefix.
Byte Bit Description
0 0 Chain Flag
0 = No CW follows this one
1 = Another CW follows
1-3 Bit Ring Sync: least-significant three bits of the Bit Ring Sync code:
001 = data field
010 = key field
011 = Rg count field
110 = Rh count field
101 = home address field
100 = contro! storage data
4-6 Not used
7 Repeat Flag
0 = Execute read command once
1 = repeat read command until overall byte count is satisfied
1 0-7 Cornmand Code: READ WITH TRANSFER = 02
2,3 0-7 Single Record Byte Count: number of bytes to be transferred in each execution of the read
command. If R=0 this will be the total number of bytes transferred.
4 0-7 Not used
5 0-7 Segment Tag
6,7 0-7 Buffer Address: address of the buffer into which the data is to be placed.
8,9 0-7 Overail Byte Count: total number of bytes to be transferred. Only present when R=1 fora
muliti-record read.
(2) Read Without Transfer
BRS
Byte Count
Command Code = 04 (Bits 0-7 of byte 1)
B-27
Table B-19. COMMAND Macro Parameter Packet Format (DCWRIT and DCFWRIT)
Command Code
Byte Count
Gap Length
Buffer Address
* This macro does not use the standard service request prefix.
Byte Bit Description
о 0 Chain Flag
О = No CW follows this one
1 = Another CW follows
1-3 Bit Ring Sync: least-significant three bits of the Bit Ring Sync Code
001 = Data field
010 = Key field
011 = Rg count field
110 = R, count field
101 = Home address field
100 = Control Storage data
4-7 Not used
1 0-7 Command Code
01 = Write
10 = Format Write
2, 3 0-7 Byte Count: number of bytes of data to be written (length of buffers).
4 0-7 Gap Length: one’s complement of the langth of the gap to be written preceding the field
itself,
5 0-7 Segment Tag
6, 7 0-7 Buffer Address: address of the buffer containing the data to be written
B-28
Table B-20. COMMAND Macro Parameter Packet Format (RESTORE)
*This macro does not use the standard service request prefix.
Byte Bit Description
0 0 Chain Flag
0 = No CW follows this one
1 = Another CW follows
1-7 Not used
1 0-7 Command Code: RESTORE = 22
2-6 - Not used
Table B-21. COMMAND Macro Parameter Packet Format (DCJUMP)
Address of Next CW
*This macro does not use the standard service request prefix.
Byte Bit Description
0 0 Chain Flag
0 = No CW follows this one
1 = Another CW follows
1-7 Not used
1 0-7 Command Code: DCJUMP = 28
2-4 0-7 Not used
5 0-7 Segment Tag
6,7 0-7 Next CW Address: locations of the CW to be executed following this one
B-29
Table B-22. WAIT Macro Parameter Packet Format
Request Code
Return Information
L A
Request Block Address (Optional)
Suffix*
Byte Bit Description
0 0-7 Request Code: WAIT=03
1 0-7 Length, number of words in the parameter packet: 3 or 4
2,3 0-7 Return Information
4 0-3 Not used
4 Count Flag: C=1 means wait for any request with count option
5 Not used
6 Wait - all flag (L)
L=1 means wait for all outstanding requests. When L=0 and A=0, wait is
„ Wait - any flag (A) for specific request.
A=1 means wait is for any outstanding request.
5 0-7 Segment Tag
6,7 0-7 Request Block Address: address of request block for wait-specific. Only present when
L=0 and A=0,
*The 2-character suffix for unique file identifier.
B-30
Table B-23. POST/RPOST Macros Parameter Packet Format Suffix *
0 Request Code FL
2 | Return Information CR
4
6 Buffer Address IN
Byte Bit Description
0 0-7 — Request Code: POST=43,RPOST=44
1 0-7 Length, number of words in the parameter packet: 04
2,3 0-7 | Return Information
4 | 0-7 Not used
5 0-7 Segment Tag
6, 7 | 0-7 Buffer Address: address of an 8-byte buffer, This will either contain the information to be
| posted (POST) or will receive the interpreted information from the system (RPOST).
*The 2-character suffix for unique file identifier.
Table B-24. SETCOM/GETCOM Macros Parameter Packet Format Suffix *
0 Request Code * Length
2 Return Information
6 | — Buffer Address
Byte Bit Description
0 0-7 | Request Code: SETCOM=47,GETCOM=48
1 0-7 - Length, number of words in the parameter packet: 04
2,3 0-7 | Return Information
4 0-7 Not: used
5 0-7 Segment Tag
6, 7 0-7 Buffer Address: address of an 8-byte buffer. This will either contain the information to be
transferred (SETCOM) or will receive information from the system (GETCOM). |
*The 2-character suffix for unique file identifier.
B-31
Table B-25. ACCEPT Macro Parameter Packet Format
Suffix **
of Request Code Length FL
2 Return Information CR
N S H S TAG BT
6 Buffer Address BF
al S TAG _
10 End Address EN
12 S TAG
14 2 0 eL Number Address (Optional) ~~ __ _ _ __ _ _ JN
Byte Bit Description
0 0-7 Request Code: 13
1 0-7 Length, number of words in the parameter packet: 6 or 8
2,3 0-7 Return Information
4 0-4 Not used
5 Number Flag
0 = number not specified (current value of //PAR card pointer will be used)
1 = //PAR card number is specified in word at displacement 16
6 Strip Flag
1 = strip sequence number field
0 = do not strip sequence number field (card cols 73-80)
7 Control Header Flag
1 = include CSDF header
0 = do not include CSDF control header
have been read.
5 0-7 Segment Tag
6,7 0-7 Buffer Address: address of buffer into which data from //PAR card is to be transferred.
8 0-7 Not used
9 0-7 Segment Tag
10,11 0-7 End Address: address to which program control will be transferred when all //PAR cards
14* 0-7 Not used (optional)
15* 0-7 Segment Tag (optional)
16*,17* 0-7 Number Address (optional): address of one-word location containing the //PAR card number
*| ast four bytes will only be present when number flag (N) = 1.
**The 2-character suffix for unique file identifier.
B-32
Table B-26. MEML.IM Macro Parameter Packet Format Suffix *
Request Code - Length
Return Information
Buffer Address
Byte Bit Description
О 0-7 Request Code: MEMLIM=46
1 0-7 Length, number of words in the parameter packet: 04
2,3 0-7 Return Information
4 0-7 Not used
5 0-7 Segment Tag
6,7 07 | Buffer Address: Address of buffer into which last page address is to be placed.
*The 2-character suffix for unique file identifier.
Table B-27. INFORM Macro Parameter Packet Format Suffix*
Request Code | Length
Return Information
Count Address
Byte Bit Description
О 0-7 Request Code: INFORM=05
1 0-7 Length, number of words in the parameter packet: 04
2,3 0-7 Return Information
4 0-7 Not used
5 0-7 Segment Tag
6,7 0-7 Count address: address of a one-word location containing a count of the number of requests
: not known to have completed at this time.
*The 2-character suffix for unique file identifier.
B-33
Table B-28. SETIF Macro Parameter Packet Format Suffix*_
Request Code FL
Return Information CR
Buffer Address IN
Byte Bit Description
0 0-7 Request Code: SETIF=45
1 0-7 Length, number of words in the parameter packet: 04
2,3 0-7 Return Information
4 0-7 Not used
5 0-7 Segment Tag
6,7 0-7 Buffer Address: address of a one-byte buffer containing the data to be transferred.
*The 2-character suffix for unique file identifier.
B-34
Table B-29. DELAY Macro Parameter Packet Format Suffix**
Request Code . Length
Return Information
B T
Delay Address
Byte Bit | Description
0 0-7 Request Code: DELAY=04
1 0-7 Length, number of words in the parameter packet: 04
2,3 0-7 Return Information
4 0-5 Not used
6 Break Flag (B)
0 = no delay break
1 = delay to be broken on any service request completion
7 Type Flag (T)
О = delay in seconds
1 = delay in cycles*
5 0-7 Segment Tag
6,7 0-7 | Delay Address: address of a one-word buffer containing the duration of the delay in seconds
or cycles* (see Type Flag).
*Cycle equals 50.2 milliseconds.
**The 2-character suffix for unique file identifier.
B-35
Table B-30. HALT Macro Parameter Packet Format Suffix*
0 Request Code Length FL
2 Return Information CR
Byte Bit Description
0 0-7 Request Code: HAL T=64
1 0-7 Length, number of words in the parameter packet: 02
2,3 0-7 Return Information
*The 2-character suffix for unique file identifier.
Table B-31. EHALT Macro Parameter Packet Format Suffix*
0 Request Code Length FL
2 Return Information CR
Byte Bit Description
0 0-7 Request Code: EHALT=65
1 0-7 Length, number of words in the parameter packet: 02
2,3 0-7 Return Information
*The 2-character suffix for unique file identifier.
B-36
Table B-32. ABEND Macro Parameter Packet Format Suffix *
0 Request Code Length FL
2 Return Information CR
4 STAG
6 Buffer Address IN
Byte Bit
0 0-7 Request Code: ABEND=75
1 0-7 Length, number of words in the parameter packet: 04
2,3 0-7 Return Information
5 0-7 Segment Tag
6,7 0-7 Buffer Address: address of location containing the completion code.
*The 2-character suffix for unique file identifier.
Table B-33. TIME Macro Parameter Packet Format Suffix*
0 Request Code Length FL
2 Return Information CR
4 STAG
6 Buffer Address IN
Byte Bit
0 0-7 Request Code: TIME=73
1 0-7 Length, number of words in the parameter packet: 04
2,3 0-7 Return Information
5 0-7 Segment Tag
6,7 0-7 Buffer Address: address of location containing the time
*The 2-character suffix for unique file identifier.
B-37
Table B-34. SDATE Macro Parameter Packet Format
Suffix*
0 Request Code Length FL
2 Return Information CR
4 D S TAG BT
6 Buffer Address IN
Byte Bit Description
0 0-7 Request Code: SDATE=74
1 0-7 Length, number of words in the parameter packet: 04
2,3 0-7 | Return Information
4 7 Date Flag
O = Calendar date
1 = Julian date
5 0-7 Segment Tag
6,7 0-7 Buffer Address: address of location containing the date
*The 2-character suffix for unique file identifier.
Table B-35. JDATE Macro Parameter Packet Format Suffix*
0 Request Code Length FL
2 Return Information CR
4 D STAG BT
6 Buffer Address IN
Byte Bit Description
0 0-7 Request Code: JDATE=66
1 0-7 Length, number of words in the parameter packet: 04
2,3 0-7 Return Information
4 7 Date Flag
O = Calendar date
1 = Julian date
5 0-7 Segment Tag
6,7 0-7 Buffer address: address of location containing the date
*The 2-character suffix for unique file identifier.
B-38
Table B-36. CONSOLE Macro Parameter Packet Format
Suffix*
0 Request Code Length FL
2 Return Information CR
4 S TAG
6 Buffer Address BF
8 STAG
10. Reply Address IN
Byte Bit Description
0 0-7 Request Code: CONSOLE=01
1 0-7 Length, number of words in the parameter packet: 04 (without reply) or 06 (with reply)
2,3 0-7 Return Information
5 0-7 Segment Tag
6,7 0-7 Buffer Address: address of location containing message
9 0-7 Segment Tag
10,11 0-7 Reply Address: address of location containing reply message.
*The 2-character suffix for unique file identifier.
B-39
INTRODUCTION
Of the various classes of possible errors associated
with a service request, the operating system's error
recovery program is concerned ‘with only one
particular class: the input/output hardware
malfunctions. Attempted recovery from these
input/output hardware malfunctions will be
performed for all levels of input/output coding by
default: however, at the physical level it may be
bypassed if specified.
If an error proves to be irrecoverable, information
describing the error is returned to the user's request
or command block (Table C-1) and then, normally,
the job is aborted. However, if the operand,
ERRCOMP=YES had been coded in the original
request, control is returned so that the user may
either ignore the error or attempt to process it
himself.
In addition to its basic task of attempting to recover
from errors, the error recovery program is also
responsible for handling certain exceptional non-error
situations, such as EOF detection and indication.
TYPES OF ERROR
The following major categories of error are handled
by the error recovery program.
INTERVENTION REQUIRED
When operator intervention is required, a console
message is issued. Once the operator has serviced the
device, he responds to the message indicating either
to continue processing or to return control to the
user. The MRX/OS Messages manual contains the
operator console messages.
C. ERROR RECOVERY
ERRORS REQUIRING RETRIES
Input/output requests completed but including
specific types of errors are retried a given number of
times. If the error persists, a message is typed on the
operator's console. The operator response indicates
either to retry the request another specific number of
times or to return the error condition indication to
the user program. If one of the retries succeeds, a
normal completion indication is returned to the user
program as though no error had occurred.
CONDITIONS OF UNCERTAINTY
There are certain error conditions where the error
recovery program is unable to perform accurate error
recovery, or any error recovery at all; for example,
not being sure where magnetic tape is positioned.
Although the error recovery program checks all
defined hardware conditions, it is not inconceivable
that an undefined condition from a non-supported
hardware device might arise; in this case the error
recovery program is unable to process it.
With regard to the first example, it should be noted
that although the error recovery program checks all
defined hardware conditions, it is not inconceivable
that an undefined condition might arise; in this case
the error recovery program is unable to process it.
When error conditions of this kind occur, a message is
typed on the operator's console. If the message
requires a response and the operator chooses to
continue, the user may either gain or lose
information. If the message does not require a
response, the request is routed back to the user with a
return code.
C-1
IMMEDIATE IRRECOVERABLE CONDITIONS
An example of an error so classified is that of
magnetic tape running off the end of the reel. In
situations such as this, a console message is typed and
the request is routed back to the user with a return
code.
CONDITIONS THAT DO NOT REQUIRE
RECOVERY
Certain conditions routed to the error recovery
program are considered to be normal completions and
do not require the issuance of any return codes or
error messages. Two examples are these:
e a parity error while spacing magnetic tape
(no recovery is needed because tape is
properly positioned)
e detection of an end-of-file condition
C-2
ERROR LOGGING
Error logging is an integral part of the operating
system. The error log file, which is built at system
generation time, consists of forty-byte records (Table
C-2).
Records of error conditions and retries are
maintained in the two error flag bytes and two error
counters, respectively (located in the extension area
of each unit table entry). The bits of the error flag
bytes represent the error conditions that can occur. If
multiple errors occur, bits are set as the error
conditions are detected.
The error counters are incremented by 1 whenever a
retry error condition occurs. Each error counter can
contain more than one error condition.
Table C-1. 1/0 Error Recovery Information
Hexadecimal PCB/Request| Message |
. Status FDT Block Return Code Console Must Error Log
Completion | Return | Information | Displayed | Message No. of File be Record
Condition Code Information Field On Console Reply Retries* Reset Written
EOA on this disc request 0 0 A000 — — 0 N
Channel 12 on the printer carriage 0 о A001 — — 0 N N
control tape
This request was not processed be- — Old C001 — — 0 Y N
cause an exception condition
occurred on a previous reguest and
the file has not been reset
Disc EOF 0 0002 A002 — — 0 N
Unit down 5002 0002 C002 002 — 0 N
Card reader EOF 0 0003 A003 — — 0 N
Invalid function code in command 5003 — C003 — — 0 — N
program
Channel 9 on the printer carriage 0 0 A004 — — 0 N N
contro! tape
A Remove request removed this 5004 — C004 — — 0 — N
request |
Length error. A record was read 0 0 C005 — — 0 N N
which was longer than the buffer
space provided for it |
Tape mark sensed on any Read О 0006 A006 — — О Y N
operation not including Search
command
An ASKATT request is being re- 5006 — C006 — — 0 — N
jected because an ASKATT is
already pending against the device
Error status indication returned 5010 0010 C010 — — 0 — N
from an 1/0 operation
_ Operation timed out 5011 0011 CO11 011 N/Y 1 Y Y
Unsolicited attention set 501 2 0012 co? 012 — 1 Y N
Bad 1/0 status indication from Seek 5013 0013 C013 — — 0 Y №
or Restore
No error recovery for device 503F 003F CO3F — — 0 Y N
Invalid function code in BIO macro 5020 0 C020 — — 0 N N
Invalid block number 5021 0 C021 — — О N N
Invalid byte count 5022 0 co22 _ — 0 N N
Invalid CNTRL request 5023 0 C023 — — 0 N N
No FDT 5024 — C024 — — 0 N N
Usage error 5025 0 C025 — — 0 N N
Operation to locked file 5026 0 C026 — — 0 N N
Invalid sequence of operations to 5027 0 C027 — — 0 N N
a device
Subfunction field error 5028 C028 — — 0 N N
Invalid position (to magnetic tape 5029 0 C029 — —
file that is not maintaining block
numbers)
EOF on a read to a bypassed file о 0 АО2А — — 0 N
| Invalid unit ordinal on privileged 5030 — C030 — — 0 —
PIO request
*Number of retries automatically performed by Error Recovery before completion is declared.
Table C-1. 1/0 Error Recovery Information (Continued)
Hexadecimal PCB/Request| Message
Status FDT (Block Return| Code Console Must Error Log
Completion Return | Information | Displayed | Message No. of File be Record
Condition Code Information Field On Console Reply Retries Reset Written
DISC
Timeout 5041 0041 C041 041 — 10 Y Y
Command reject 5042 0042 C042 042 — 0 Y N
Disc write current 5043 0043 ~ C043 043 — 0 Y Y
Seek incomplete 5044 0044 C044 044 — 10 Y Y
Not on line 5045 0045 C045 045 Y/N 1 Y N
File unsafe 5046 0046 C046 046 — 0 Y Y
Pack change 5047 0047 co47 047 — О Y N
Status not valid 5048 0048 C0438 048 — 0 Y Y
Command early 5049 0049 C049 049 — о Y Y
Unsolicited Attention 504A 004A | CO4A 04A — 1 Y N
Catastrophic error 504B 004B C04B 04B Y/N 0 Y Y
Missed window 504C 004C C04C 04C — 10 Y ON
IFA window 504D 004D 04D 04D Ш 10 a Y
Track boundary 504E 004E CO4E 04E — 10 Y N
Read Write terminate 504F 004F CO4F 04F — 10 Y Y
Burst check 5050 0050 Coso 050 — 10 Y Y
Lost data 5051 0051 C051 051 — 10 Y Y
No sync compare 5052 0052 C052 052 — 10 Y Y
Write operation issued to a drive 5053 0053 C053 053 Y/N 1 Y N
in read only mode
End of cylinder 5054 0054 C054 054 — 10 Y Y
Busy 5055 0055 C055 055 — 10 Y Y
Invalid seek address 5056 0056 C056 056 — 0 Y №
Search failed (arm mispositioned) 5058 0058 C058 058 — 5. Y Y
Search failed (no record found) 5059 0059 C059 059 — 5 Y N
PRINTER
Command reject 5064 0065 C064 — — 0 Y N
1/O Channel error 5065 0065 C065 065 Y/N 1 Y Y
Data check 5066 0066 C066 — — 0 Y Y
Not ready 5067 0067 C067 067 Y/N 1 Y N
Bus out check 5069 0069 C069 069 Y/N 1 Y Y
Catastrophic error 506A 006A CO6A 06A Y/N 1 Y Y
Both channel 9 and 12 on the 0 0 A06B — — 0 N N
printer carriage control tape
Table C-1. 1/0 Error Recovery Information (Continued)
Hexadecimal PCB/Request| Message
Status FDT [Block Return] — Cade Console Must Error Log
Condition 'Completion uno Information Displayed Ro Re of File be econ
Code Field On Console
CARD READER
Catastrophic error 5070 0070 C070 070 Y/N Y N
‘Command reject 5071 0071 C071 — — 0 Y N
Not ready 5072 0072 C072 072 Y/N 1 Y N
Busy 5073 0073 C073 — — 10 Y Y
Feed check or jam 5074 0074 C074 074 Y/N 1 Y Y
Read check 5075 0075 C075 075 Y/N 1 Y Y
Data check (illegal EBCDIC char.) 5176 0076 C076 076 Y/N 1 Y N
Time out 5077 0077 C077 — — 10 Y Y
Unsolicited attention 5078 0078 C078 078 — 1 Y N
Initial selection error 5079 0079 C079 — — 10 Y Y
CARD READER PUNCH |
Catastrophic error 5080 0080 C080 080 Y/N 0 Y N
Command Reject 5081 0081 C081 — — 0 Y N
Not ready 5082 0082 C082 082 Y/N 1 Y N
Busy 5083 0083 совз - — 10 Y Y
Feed check or jam 5084 0084 C084 084 Y/N 1 Y Y
Data check (illegal EBCDIC char.) 5085 0085 C085 085 Y/N 1 Y N
Read check | 5086 0086 C086 086 Y/N 1 Y Y
Time out 5087 0087 C087 — — 10 Y Y
Unsolicited attention 5088 0088 C088 088 — 1 Y N
Initial selection error 5089 0089 C089 — — 10 Y Y
Punch check 508A 008A СОВА 08A YIN 1 Y Y
MAGNETIC TAPE
| Command reject (read reverse) 50A1 00A1 COA1 — — 0
| Command reject (protected tape) 50A1 00A1 COA1 0A1 — ) Y
| Intervention required (without 50A2 00A2 СОА2 0A2 Y/N 1
equipment check)
Intervention required (with 50A3 O0A3 COA3 | 0A3 — 0 Y Y
equipment check)
| Bus out check (on command) 50A4 00A4 COA4 | 0A4 Y/N 10 Y Y
| Bus out check (on data) | 50AS O0AS COAS5 OA5 Y/N 10 Y Y
Equipment check (Read Write reg.) 50A6 00A6 — COAG ОАб YIN 10 Y Y
Equipment check (Write register) 50A7 00A7 СОА7 0A7 Y/N 1 Y Y
Equipment check (Read register) on 50AS 00A8 COAS 0A8 Y/N 1 Y Y
a
| Equipment check (Read register) 50A8 O0AS COAS `ОАВ — 0 —Y Y
| on command
| Equipment check (Delay register) 50A9 00A9 COA9 ОАЭ Y/N 1 Y Y
Table C-1. 1/O Error Recovery Information (Continued)
Hexadecimal PCB/Request| Message E L
Status FDOT Block Return Code Console Must Rec a
Completion Return Information | Displayed | Message No. of File be ecor
Condition Code Information Field On Console Reply Retries Reset Written
Equipment check (Delay register) 50A9 00A9 COA9 om | — 0 Y Y
on command
Data check (Write) 50AA ODAA COAA CAA Y/N 10-5
Data check (Write File Mark) 50AB 00AB COAB DAB Y/N 10
Data check (multiple track error 50AC 00AC COAC ОАС Y/N 10
on read)
Data check (single track error on 50AD ODAD COAD OAD Y/N 10 Y Y
read) Includes preamble and post -
amble errors
Data check (phase track in error 0 0 0 — — 0 N Y
and VRC without Read Write
register error)
Data check (Erase) 50AE 00AE COAE OAE Y/N 1 Y Y
‘Over run SOAF OOAF COAF OAF Y/N 10
Word count zero (Write Command 5080 0080 COBO ово — 10 Y Y
Count # 0)
Not capable 50B 1 00B1 COB1 0B1 Y/N 1 Y N
Backspace into BOT 0 00B2 AOB2 — — 0 Y N
Reverse Head command at BOT 50B4 00B4 COB4 — — 0 Y N
EOT during any write operation 0 0085 АОВ5 — — 0 Y N
Unsolicited attention 50B6 COB6 COB6 OB6 Y/N 1 Y N
Time out 5087 00B7 COB7 087 — 0 Y Y
Undefined IOC error 50B8 00B8 COB8 0B8 N 0 Y N
Internal recovery error No. 1* 50B9 00B9 COB9 0B9 N 10 Y Y
internal recovery error No. 2* 50BA COBA COBA OBA N 0 Y Y
Internal recovery error No. 3* 50BB COBB COBB OBB N O Y N
155 channel error 50E1 00E1 COE1 OE1 Y/N 10 Y Y
Wrong address-in channel error 50E2 00E2 СОЕ2 ОЕ2 Y/N 10 Y Y
Control check channel error 50E3 00E3 COE3 ОЕЗ Y/N 10 Y Y
Transmission check channel error 50E4 00Е4 COE4 0E4 Y/N 10 Y Y
Zero byte count 50E5 00Е5 COES — — 0 Y N
*Catastrophic error.
C-6
Table C-2. Error Log Record
0 ID DATE/TIME
2 DATE/TIME DATE/TIME
4 DATE/TIME DATE/TIME
6 DATE/TIME DATE/TIME
8 DATE/TIME DATE/TIME
10 DATE/TIME DATE/TIME
12 DATE/TIME PROCESSOR
14 DEVICE ADDR CMD IN ERROR
16 STATUS STATUS
18 : ER FLAG BYTE O ER FLAG BYTE 1
20 ERROR COUNTER 1 ERROR COUNTER 2
22 ERROR COUNTER 30R CYLINDER ERROR COUNTER 4 OR HEAD
24 VOL ID VOL ID
26 VOL ID VOL ID
28 VOL ID VOL ID
30 SENSE SENSE
32 SENSE SENSE
34 SENSE SENSE
36
38 RECORD SEQ. NUMBER RECORD SEQ. NUMBER
Bytes Mnemonics Description
0 iD Identification of the record. The value of this field is as follows:
Hex Value Explanation
01 from disc error recovery
02 from tape error recovery
03 from card reader error recovery
04 from card reader punch error recovery
05 from printer error recovery
06 from logical communications error recovery
07 from error correction code feature (optional)
1-12 DATE/TIME The date and time which are supplied by the Exec are in a binary format as follows:
Byte Explanation
1 unused
2 year
3 month
4 day
5 hour
6 minutes
7-10 seconds
11-12 hardware clock
C-7
Bytes
13
14
15
16-17
18-19
C-8
Mnemonics
PROCESSOR
DEVICE ADDR
CMD IN ERROR
STATUS
ER FLAG BYTE 0& 1
Table C-2. Error Log Record (Continued)
Description
Processor state which the device uses. The processor codes are as follows:
Hex Code
08
04
02
01
Processor
Zero
one
two
three
The physical device address. The physical device address for disc is the cable address (not the
plug address).
The command code that the driver is attempting to execute when the error condition occurs.
The two bytes of hardware status indication.
Flag bits set by error recovery modules when the different error conditions occur. The two
flag bytes are described as follows:
Flag Byte O
Bit
SO USW N —= ©
Flag Byte 1
Bit
CN = ©
Fiag Byte O
Bit
“O0 0 SON -=—0
Magnetic Tape
Explanation
intervention required
bus out check
equipment check (register parity)
equipment check (internal counter)
data check
over run
word count zero
preamble/postamble error
Explanation
timeout error
ISS channel error
wrong address-in channel error
control check channel error
transmission check channel error
unused
Disc
Explanation
command early
timeout
disc arm mispositioning
unused
read/write terminate
catastrophic error
lost data
no sync compare
Table C-2. Error Log Record (Continued)
Bytes Mnemonics Description
Flag Byte 1
œ
=
Explanation
third revolution sync find
seek incomplete
file unsafe
missed window
burst check
end of cylinder
disc write current
busy
NoaswN =O |
Card Reader and Reader Punch
Fiag Byte O
0
=
Explanation
timeout
busy
ISS channel error
catastrophic error
punch check
command reject
read check
card feed check or jam
vouson-o |
Flag Byte 1
Bit Explanation
0-7 unused
Printer
Flag Byte O
o
=
Explanation
timeout
unused
bus out check
data check
invalid sense information
NOOO ©
A
Flag Byte 1
u
=
Explanation
ISS error
unused
wrong address in initial selection or address/status parity
no request in S10 poll sequence request
control check
data transmission check
-7 unused
DOH WN =O
Note: The printer hardware status bytes that are written in the error log file represent
all of the conditions that occurred while printer error recovery was in progress
for a given error. Therefore, if a channel error occurs during recovery procedures,
it will appear in the two hardware status bytes.
Bytes
20
21
22
23
24-29
30-35
36-37
38-39
C-10
Mnemonics
ERROR COUNTER 1
ERROR COUNTER 2
ERROR COUNTER 3
or CYLINDER
ERROR COUNTER 4
or HEAD
VOLID
SENSE
Table C-2. Error Log Record (Continued)
Description
The following errors use Counter 1:
1. Card Reader and Card Reader Punch Error Recovery error conditions.
2. Disc Error Recovery error conditions except search failures.
3. Magnetic Tape Error Recovery for user request error condition.
The following errors use Counter 2:
1. Disc Error Recovery for a search failure.
2. Magnetic Tape Error Recovery for recording the number of erase operations
performed during the recovery of a write operation.
Error Counter 3 is incremented by the Magnetic Tape Error Recovery for positioning
errors. Or, the disc's cylinder number is extracted from the seek argument of the first
command word in a command program. If the first command word is not a seek, the
cylinder number is not supplied.
Magnetic Tape Error Recovery uses Counter 4 as a record counter. Bits 0-3 are used
when positioning forward and bits 4-7 are used when positioning backward. The
disc's head number is extracted from the seek argument of the first command word
in a command program. If the first command word is not a seek, the head number is
not supplied.
Volume ID. This field applies only to disc.
From one to six sense bytes depending on the type of device. See the associated hardware
specification for the bit positions and their meanings.
Unused.
Record sequence number.
D. GAP SPECIFICATIONS
Table of Gap specifications to be used with the COMMAND/OPCODE=DCWRIT macro when working
with fixed record lengths (and no key fields).
Record Size Number of
in Bytes Records in Track GAP (Inverted Hex)
3521 — 7294 1 None
2299 — 3520 2 67
1694 — 2298 3 9C
1333 — 1693 4 B6
1093 — 1332 5 C5
922 — 1092 6 DO
794 — 921 7 D7
695 — 793 8 DC
616 — 694 9 El
551 — 615 10 E4
497 — 550 11 E7
451 — 496 12 E9
412 — 450 13 EB
378 — 411 14 ED
348 — 377 15 EE
322 — 347 16 FO
299 — 321 17 F1
277 — 298 18 F2
259 — 276 19 F3
242 — 258 20 F3
227 — 241 21 F4
212— 226 22 Fb
200 — 211 23 F5
188 — 199 24 F6
177 — 187 25 F6
167 — 176 26 F7
158 — 166 27 F7
149 — 157 28 F8
140 — 148 29 F8
133 — 139 30 F9
126 — 132 31 F9
119 — 125 32 F9
113— 118 33 F9
107 — 112 34 РА
101 — 106 35 FA
95 — 100 36 FA
81— 94 37-39 | FB
62— 80 40-44 FC
46 — 61 45-49 FD
33— 45 50-54 FE
23— 32 55-59 FE
13— 22 60-64 FE
0— 12 65-73 FF
D-1
1-3
F
CC
HH
В
К
DD
FB
SB
IC
BC
GO
G2
G4
CIEN | Eis | | В F|S|1|B FÍS|TB
F|C|C|H|H FIC|ICIHIHIRIK)D|D | Р 1$ |1 IB Р|5 |1 |В
BIBICIC BÍBIEIC BIBICION ПЕ CIE|AAIR IKIDID epic B|sicic в| в| с/с
rN A A k k
- RO DATA N | | DATA 5
HOME RO COUNT
G4} ciagursy) IS 9+4 (BURST) Ss VARIABLE si 94 (BURST) = 0 TO 255 x 7294 60
BYTES BYTES (8+4) TO BYTES BYTES (MAX)
FULL TRACK BYTES
__—— GAPBITCONFIGURATION >
ss , — —
BIT RING
VARIABLE AREA VFO AREA 5 BYTES TEs SYNC AREA
= N 1 BYTE
ONES ONES SEE
ONES ONES ONES ZEROS ZEROS ONES 5 BITS MISSING 5 BITS MISSING TRACK
CLOCK PULSES | CLOCK PULSES FORMAT
eat atl
1171111111111 1111111111110000000000000000{1 1111111111711 111(11 111111
N
FLAG BYTE
CYLINDER NUMBER IN BINARY |
HEAD NUMBER IN BINARY SYNC BYTE CONFIGURATIONS
TRACK RECORD NUMBER IN BINARY
"e a FIELD LENT IN BINARY HA RO COUNT RO DATA Ry COUNT KEY Ry DATA
| NGTH IN BINARY
SYNC SYNC SYNC SYNC SYNC SYNC
FIRST (CYCLIC BURST) BYTE BYTE BYTE BYTE BYTE BYTE BYTE
SECOND (CYCLIC BURST) BYTE
INDICATOR BYTE
BIT COUNT BYTE
41 BYTES + 0.043 X (Kg + Dy)* 1310 1149 910 1419 1010 910
41 BYTES |
73 BYTES
" 00001101 00001011 00001001 00001110 00001010 00001001
* BURST CHECK BYTES NOT INCLUDED \ E 3 = =}
Ww nan Nu Hn Ha HU Wu nN
1VWHO4 HOVUL OSIG ‘3
F. INDEX—BLOCK SIZE FOR INDEXED FILES
There is a minimum index block size for every
indexed file depending on key size and file size. The
user may utilize any index block size larger than the
minimum, if he has memory space for a larger index
block. The larger the index block the better retrieval
becomes on random processing. If the user goes
below the minimum index block size there is the
possibility of not being able to create the file size as
planned.
When planning the creation of indexed files, the user
must decide whether he wants to process the
directory-directory, which resides on mass storage, in
a main memory buffer. This option speeds up random
_ processing, but requires extra space for the buffer. If
the mode of processing is with a main-memory buffer
there is a well-defined optimum index block size
which .minimizes memory space for the index buffer
and directory-directory buffer.
Once the user has determined his mode of processing,
Table F-1 is used to determine minimum-keys/block
and Table F-2 is used to determine optimum
keys/block. Note that in using Table F-1 and Table
F-2, the larger of the two values in the file size is the
determining factor. Also note that these tables were
computed for consistency for maximum key size and
one million records as the upper limit. There will be
some index block sizes generated that exceed one
track in number of bytes. This exceeds the system
limit for block sizes. The user will have to choose a
smaller key size or smaller file size.
The keys/block is entered in the Control Language
//DEFINE statement along with key size. The
corresponding minimum or optimum index block size
can be calculated from Table F-3. The resulting index
block size is then entered in the COBOL source
program via the INDEX-BLOCK Clause.
If the user has determined to calculate the optimum
keys/block and optimum index block size, Table F-4
is used to calculate the number of bytes for the
main-memory buffer for the directory-directory
entries.
The user must be careful not to exceed the file
maximum at creation time when using the optimum
block size — when he utilizes the main-memory
buffer to hold the directory-directory entries for
random processing, the buffer would not be able to
hold all the entries, thus writing over the user
program. Thus, when choosing an index block size
other than the optimum and the main-memory buffer
is used to process the directory-directory entries, the
buffer size should be the size of the index block, as
the system checks for overflow at creation time.
If the user wishes to calculate keys/block based on a
different file maximum than given in Tables F-1 and
F-2, the following algorithms, along with Table F-5,
can be used to compute minimum and optimum
keys/block. The constants Ko and Km are taken from
Table F-5 based on key size.
Optimum (OKB) N. Ko
Minimum (MKB) N Km
FS = Maximum File Size
NOTE: | | = Round up if result not
whole integer.
F-1
Table F-1. Minimum Keys/Block
Key Size in Bytes
11 16 21 26 36 51
Blocks in File to to to to to to
2 3 4 5 6 7 8 9 10 15 20 25 35 50 100
0 - 5,000 13 14 14 14 15 15 15 15 15 16 16 16 16 17 17
5,000 - 10,000 16 17 18 18 18 19 19 19 19 20 20 20 21 21 21
10,000 - 15,000 19 20 20 21 21 21 22 22 22 23 23 23 23 24 24
15,000 - 20,000 20 21 22 23 23 23 24 24 24 25 25 26 26 26 26
20,000 - 25,000 22 23 24 24 25 25 25 26 26 27 27 27 28 28 28
25,000 - 30,000 23 24 25 26 26 27 27 27 28 28 29 29 29 30 30
30,000 - 35,000 25 26 27 27 28 28 28 29 29 30 30 31 31 31 32
35,000 - 40,000 26 27 28 28 29 29 30 30 30 31 32 32 32 33 33
40,000 - 45,000 27 28 29 30 30 31 31 31 31 32 33 33 34 34 34
45,000 - 50,000 28 29 30 31 31 32 32 32 33 34 34 34 35 35 36
50,000 - 60,000 29 31 32 32 33 34 34 34 35 36 36 37 37 37 38
60,000 - 70,000 31 32 34 34 35 35 36 36 36 37 38 38 39 39 40
70,000 - 80,000 32 34 35 36 36 37 37 38 38 39 40 40 41 41 42
80,000 - 90,000 34 35 36 37 38 38 39 39 40 41 41 42 42 43 43
90,000 - 100,000 35 36 37 38 39 40 40 41 41 42 43 43 44 44 45
100,000 - 125,000 37 39 40 41 42 43 43 44 44 45 46 47 47 48 48
125,000 - 150,000 40 41 43 44 45 45 46 46 47 48 49 49 50 51 51
150,000 - 175,000 42 44 45 46 47 48 48 49 49 50 51 52 53 53 54
175,000 - 200,000 44 46 47 48 49 50 50 51 51 53 54 54 55 56 “ 56
200,000 - 250,000 47 49 51 52 53 54 54 55 55 57 58 58 59 60 61
250,000 - 300,000 50 52 54 55 56 57 58 58 59 61 61 62 63 64 64
300,000 - 350,000 52 55 57 58 59 60 61 62 62 64 65 65 66 67 68
350,000 - 400,000 55 57 59 61 62 63 63 64 65 67 68 68 69 70 71
400,000 - 450,000 57 60 62 63 64 65 66 67 67 69 70 71 72 73 74
450,000 - 500,000 59 62 64 65 67 68 68 69 70 72 73 74 74 75 76
500,000 - 600,000 63 66 68 69 71 72 73 73 74 76 77 78 79 80 81
600,000 - 700,000 66 69 71 73 74 75 76 77 78 80 81 82 83 84 85
700,000 - 800,000 69 72 74 76 78 79 80 81 81 84 85 86 87 88 89
800,000 - 900,000 72 75 77 79 81 82 33 84 85 87 88 89 91 91 93
900,000 - 1,000,000 74 78 80 82 84 85 86 87 88 90 92 93 94 95 96
F-2
Table F-2. Optimum Keys/Block
Key Size in Bytes
ch i ES
2 3 4 —D 6 7 8 9 10 15 20 25 35 50 100
0 - 55,000 16 17 18 18 18 19 19 19 19 20 20 20 21 21 21
5,000 - 10,000 20 21 22 23 23 23 24 24 24 25 25 25 26 26 26
10,000 - 15,000 23 24 25 26 26 27 27 27 27 28 29 29 29 30 30
15,000 - 20,000 26 27 28 28 29 29 29 30 30 31 32 32 32 33 33
20,000 - 25,000 28 29 30 31 31 32 32 32 33 34 34 34 35 35 36
25,000 - 30,000 29 31 32 32 33 34 34 34 35 36 36 37 37 37 38
30,000 - 35,000 31 32 33 34 35 35 36 36 37 37 38 38 39 39 40
35,000 - 40,000 32 34 35 36 36 37 37 38 38 39 40 40 41 41 42
40,000 - 45,000 34 35 36 37 38 38 39 39 40 41 41 42 42 43 43
45,000 - 50,000 35 36 37 38 39 40 40 41 41 42 43 43 44 44 45
50,000 - 60,000 37 39 40 41 42 42 43 43 43 45 45 46 46 47 48
60,000 - 70,000 39 41 42 43 44 44 45 45 46 47 48 48 49 49 50
70,000 - 80,000 40 42 44 45 46 46 47 47 48 49 50 50 51 52 52
80,000 - 90,000 42 44 45 47 47 48 49 49 50 51 52 52 53 54 54
90,000 - 100,000 44 46 47 48 49 50 50 51 51 53 54 b4 55 56 56
100,000 - 125,000 47 49 51 52 53 54 54 55 55 57 58 58 59 60 61
125,000 - 150,000 50 52 54 55 56 57 58 58 59 61 61 62 63 64 64
150,000 - 175,000 52 55 57 58 59 60 61 61 62 64 65 65 66 67 68
175,000 - 200,000 56 57 59 61 62 63 63 64 65 67 68 68 69 70 71
200,000 - 250,000 59 62 64 65 67 68 68 69 70 72 73 74 74 75 76
250,000 - 300,000 63 66 68 69 71 72 73 73 74 76 77 78 79 80 81
300,000 - 350,000 66 69 71 73 74 75 76 77 78 80 81 82 83 84 85
350,000 - 400,000 69 72 74 76 78 79 80 81 81 84 85 86 87 88 89
400,000 - 450,000 72 75 77 79 81 82 83 84 85 87 88 89 91 91 93
450,000 - 500,000 74 78 80 82 84 85 86 87 88 90 92 93 94 95 96
500,000 - 600,000 79 82 84 87 89 90 91. 92 93 96 97 98 100 101 102
600,000 - 700,000 83 87 90 92 94 95 96 97 98 101 102 103 105 106 107
700,000 - 800,000 87 91 94 96 98 99 100 102 102 105 107 108 110 111 112
800,000 - 900,000 90 94 97 100 102 103 105 106 106 110 111 112 114 115 116
900,000 - 1,000,000 93 98 101 103 105 107 108 109 110 113 115 116 118 120 121
F-3
F-4
Table F-3. Optimum or Minimum Index Block Size
(10) (OKB) (KS+4)
9
Optimum block size = 10 +
OKB = Optimum keys/block
KS = Key size
(10) (MKB) (KS+4)
9
Minimum block size = 10 + |
MKB = Minimum keys/block
KS = Key size
NOTE: | | = Round up if result not whole integer.
Table F-4. Bytes Required in Buffer for Directory-Directory Entries
Usage [2108810
10 = US
o rus |.
Number keys/primary index block ева | МКР
-| —US |
Number keys/directory block {ss | NKD
Total number keys represented/
directory block = (NKP) (NKD) NKRD
Number entries in _Jfile size _
Directory-directory block | NKRD | мос
Number of bytes required for
buffer for directory-directory = 10+ (KS+2) (NKDD)
entries
ore: | Round up if result not whole integer.
Round down if result not whole integer.
Table F-5. Constants for Alternate Algorithm
A
о
KS
O m о m
2 1.2500 2.5000 52 ‚5975 1.1950
3 1.0888 2.1776 53 5967 1.1934
4 .9877 1.9753 54 5959 1.1918
5 9184 1.8367 55 5952 1.1904
6 ‚8681 1.7361 56 ‚5945 1.1890
7 8299 1.6598 57 5939 1.1878
8 8000 1.6000 58 5932 1.1864
9 ‚7759 1.5518 59 5926 1.1852
10 .7562 1.5124 60 5920 1.1840
11 ‚7396 1.4792 61 5914 1.1828
12 ‚7256 1.4512 62 5908 1.1816
13 ‚7136 1.4272 63 ‚5903 1.1806
14 ‚7031 1.4062 64 ‚5897 1.1794
15 ‚6940 1.3880 65 5892 1.1784
16 6859 1.3718 66 5887 1.1774
17 ‚6787 1.3574 67 ‚5882 1.1764
18 6722 1.3444 68 5878 1.1756
19 ‚6664 1.3328 69 5873 1.1746
20 6612 1.3224 70 ‚5868 1.1736
21 .6564 1.3128 71 ‚5864 1.1728
22 .6520 1.3040 72 ‚5860 1.1720
23 ‚6480 1.2960 73 ‚5856 1.1712
24 ‚6443 1.2886 74 5852 1.1704
25 ‚6409 1.2818 75 5848 1.1696
26 6378 1.2756 76 5844 1.1688
27 ‚6348 1.2696 77 ‚5840 1.1680
28 6321 1.2642 78 5837 1.1674
29 ‚6296 1.2592 79 ‚5833 1.1666
30 ‚6272 1.2544 80 ‚5830 1.1660
31 6249 1.2498 81 5827 1.1654
32 ‚6228 1.2456 82 ‚5823 1.1646
33 ‚6209 1.2418 83 ‚5820 1.1640
34 ‚6190 1.2380 84 5817 1.1634
35 6172 1.2344 85 5814 1.1628
36 6156 1.2312 86 5811 1.1622
37 .6140 1.2280 87 5808 _1.1616
38 6125 1.2250 88 ‚5805 1.1610
39 6111 1.2222 89 .5802 1.1604
40 .6097 1.2194 90 .5800 1.1600
41 .6084 1.2168 91 .5797 1.1594
42 ‚6072 1.2144 92 5794 1.1588
43 6060 1.2120 93 5792 1.1584
44 .6049 1.2098 94 .5789 1.1578
45 .6038 1.2076 95 .5787 1.1574
46 ‚6028 1.2056 96 .5785 1.1570
47 .6018 1.2036 97 .5782 1.1564
48 .6009 1.2018 98 .5780 1.1560
49 ‚6000 1.2000 99 ‚5778 1.1556
50 5991 1.1982 100 5776 1.1552
51 5983 1.1966
F-5
INDEX
ABEND macro
ACCEPT macro
Access
random
sequential
Action macros
Add mass storage space
ALLOC macro
Allocate space
Assumed block number
Attribute element
BDT
sequential files
relative files
indexed files
Bit significance
BLKNUM parameter
BLKSIZ parameter
Block 1/0
coding
declarative macro
device control commands
error processing
file control
general description
macros
CNTRL
POSITN
READ
RESET
STATUS
TYPE
WRITE
positioning
program
reading
request termination
rules
sense information
space management
writing
BREAK parameter
BUFADR parameter
DO 53
WN
Nw
=D
> D
* <
N
wo
©
“`
© NNW ND в)
N 0 — = (J es = —
№ ©
N
Ww
©
,
2-12,20-34
2-20-23
2-24-28
2-29-34
7-22
7-11,12,13
-
- ow
-
“че
== = №) => => >
— 1 Сл — © № ©
—— —
© 00 0
1
NOT) = = — «=» = ==> ==>
“ . . .
..
WOW Wow
à à La a a
O yy
ua
СО © 69 54 NIN
©
Ça Ç ©
WH =n
3-
7-31
7-7,15,24,27
Buffer description table
general description
indexed files
relative files
sequential files
BUFSIZ parameter
Catalog elements
attribute
continuation
name
space
volume
CATALOG parameter
Central catalog
CHAIN parameter
Change current block number
Close file for data transmission
CLOSE macro |
Close volume
CLOVE macro
CNTBUF parameter
CNTRL macro
CNTSIZ parameter
COMMAND macro
basic data channel
DCABLE
DCJUMP
DCREAD
DCSEEK
DCSRCH
DCWRIT
RESTORE
Command program
Common stored data format
CON parameter
Console communication macros
CONSOLE
MESSAGE
CONSOLE macro
Index-1
2-12
2-29-34
2-24-28
2-20-23
7-15,24,27,28
2-3,6
2-3;A-6,9
2-3,4;
A-4,5
2-3,8:A-3
2-3,10
7-3,5,6
2-3;A-1;4,7
7-24:B-23
7-24:B-24
7-30;B-29
7-28;В-27
7-24:B-25
7-27;B-26
7-29:B-28
7-30:B-29
4-1
2-1
7-3
CONTROL parameter
Control program macros
ABEND
ACCEPT
DELAY
DISPLAY
EHALT
GETCOM
HALT
INFORM
JDATE
MEMLIM
POST
RPOST
SDATE
SETCOM
SETIF
TIME
WAIT
Control program services
finding partition size
inter-step and contro! language
communication
reading data from //PAR cards
service request control
writing to SYSOUT
CP parameter
CPADR parameter
Create communication byte
CSD parameter
CWADR parameter
CYCLES parameter
Data macros
Data structures
DATACYL parameter
DATATXT parameter
DATBUF parameter
DATABUF1 parameter
DATABUF2 parameter
DATSIZ Parameter
DATSIZ1 parameter
DATSIZ2 parameter
Define file label
Defining and opening devices
DEF LB macro
DELAY macro
Device and file type
Device control commands
DEVTYP parameter
B-1
2-1
7-3
7-38
7-10,12,28,
29,35
7-34,38
7-38
7-10,12,28,
29,35
7-38
7-38
7-2
Disc catalog
central
pack
Disc track format
DISPLAY macro
EBCDIC parameter
EHALT macro
ELEMENT parameter
End conditions
EOF
ЕОА
ЕОТ
ENDADR parameter
ERRCOMP parameter
ERROPT parameter
Error log record
Error logging
Error processing
Error recovery
types of errors
intervention required
retries
information
uncertain conditions
irrecoverable conditions
error logging
EXCP instruction
EXCP macro
Expand from communication byte
EXPND macro
FDT
FIELD parameter
File control
general description
macros
CLOSE
CLOVE
OPEN
File description table
File label (tape)
File organization
FILENAM parameter
Index-2
2-2,3:A-1,
4,7
2-2,3;A-1,2
E-1
5-2:7-1,35
7-10,12
7-1,37:B-36
7-9
3-3
3-4
3-4
7-34
3-4:7-3, |
5 thru 10,12
thru 15,21,23,
30 thru 36;
B-4
2-12,13 thru
19:3-4;7-2
7-27,28,30
3-3
6,7;
14
6,8;
“
-
-15
-1,6;B-12
2,13 thru
;3-
2
4;7-2
1
r
NNNDNANSIONON
-1
-1
2
FILEORG parameter
Files
indexed
relative
sequential
FILESIZ parameter
FILETYP parameter
Fixed length records
FUNCTN parameter
GAP parameter
Gap specification
Generation of reply buffer
GETCOM macro
HABUF parameter
HALT macro.
Hardware control operation
HASIZ parameter
IDENT parameter
Identify partition limit
INDCYL parameter
Index block size
Indexed files
INDSIZ parameter
INFOADR parameter
INFORM macro
Input/output action
Input/output levels
logical
block
physical
Interaction of Data Management
and Control Language
1/0 service macro (LABRTN)
IOTYP parameter
JDATE macro
KEYBUF parameter
KEYSIZ parameter
LABDEF parameter
LABDEF1 parameter
LABDEF? parameter
Labels
tape
disc
LABRTN macro
NANA NY
o
o
1 O
A с
==>
с
Ww
ONO
«т
7-28,29
7-1,36;B-36
7-13
7-28,29
7-3 thru 10,
12 thru 15,21
7-35
7-3,4
F-1
2-1
7-3,4
7-9,32,33,
36,37
5-1;7-1,31;
B-33
7-22
1 1
71,
,
NN
NNO)
-1
-1,
-7
#
9:B-16
8
7-1,37:B-38
7-28,29
7-3,4,28,39
7-5,6,7
7-3,4
7-3,4
,2
‚3
‚9:B-16
NNN
= №) =a
LIST parameter
LOCK parameter
Logical 1/0
Macro expansions
Macros
Index-3
ABEND
ACCEPT
ALLOC
CLOSE
CLOVE
CNTRL
COMMAND
CONSOLE
DEFLB
DELAY
DISPLAY
EHALT
EXCP
EXPND
GETCOM
HALT
INFORM
JDATE
LABRTN
MEMLIM
MESSAGE
OPEN
PCB
POSITN
POST
PURGE
READ
RESET
GN GN
1 =. 1
7-3 thru 10,
12 thru 15,21,
30 thru 36:8-3
7-8
1-1
59
—
o
JW
N
со
“NW
ws -
NND
©
.
WN =
NO
—
со ©
B 0
sd
=. “ —
=
- a 1 -
WWW NWE EN
-
> “=
N SS — 2 —
“а - Ss
_ WOW
“ oO
DD
N
Ja
+
>
=
с
“=
— ON
«—
CO :
© ©
8:B-39
“а
UV NU
_—
с)
—
Г
!
DO NNN WD = WN
со — — —
O]
—
со
O1
со — 2 WIN
© ©
LNW
— С)
NDS
Nu
-
w
©
>
“SUSHNWN
Da NANA INE
—
00 © — с
оо юн
со — № ю =
-
-
NW=wN
NO Ww
Vowno-
== È
> ©
-
NS
NC
a
Macros (continued)
RPOST
SDATE
SETCOM
SETIF
STATUS
TIME
TYPE
WAIT
WRITE
MEMLIM macro
MESSAGE macro
MODE parameter
MSC parameter
MULTBLK parameter
Multi-volume file processing
Name element
OPCODE parameter
OPEN macro
OPER parameter
Pack catalog
PAIRED parameter
Parameters
BLKNUM
BLKSIZ
BREAK
BUFADR
BUFSIZ
CATALOG
CHAIN
CNTBUF
CNTSIZ
CON
CONTROL
CP
CPADR
CSD
CWADR
CYCLES
1:B-19
2-3,4:A-5
7-24,27
thru 30
3-3;6-1;
7-1,6;B-12
7-11,12,14
2-3:A-1,2
7-5,6
7-11,12,13
7-3
7-31
7-7,15,24,27
7-15,24,27,
28
7-3,5,6
7-24,27,28,
30
7-28,29
7-28,29
7-35
7-7
7-22
7-23
7-3,34
7-30
7-31
Parameters (continued)
DATATXT
DATACYL
DATBUF
DATBUF1
DATBUF2
DATSIZ
DATSIZ1
DATSIZ2
DEVTYP
EBCDIC
ELEMENT
ENDADR
ERRCOMP
ERROPT
FIELD
FILENAM
FILEORG
FILESIZ
FILETYP
FUNCTN
GAP
HABUF
HASIZ
IDENT
INDCYL
INDSIZ
INFOADR
IOTYP
KEYBUF
KEYSIZ
LABDEF
LABDEF1
LABDEF2
LIST
LOCK
MODE
MSC
MULTBLK
OPCODE
OPER
PAIRED
Index-4
7-38
7-3
7-10,12,28,
29,35
7-34,38
7-38
7-10,12,28,
29,35
7-38
7-38
7-23
7-10,12
7-9
7-34
3-4:7-3,5
thru 10,
12 thru 15,
21,23,30
thru 36;,B-4
4-3:7-23
7-27,28,30
7-2
73
7-3,4,5
7-34
7-23
7-29
7-28,29
7-28,29
7-3 thru 10,
12 thru 15,21
7-3,4
7-34
7-9,32,33,
36,37
7-7,8
7-28,29
7-3,4,28,39
7-5,6,7
7-34
7-3,4
7-3 thru 10,
12 thru 15,
21, 30 thru
36:B-3
7-8
7-30,37,38
7-2
7-11
7-24,27
thru 30
7-11,12,14
7-5,6
Parameters (continued)
PARNUM
PCB
RECSIZ
REQADR
REQCNT
RETURN
REWIND
SECONDS
SEEK
SIZERR
SKIP
SPREAD
STRIP
UNORD
USAGE
VERIFY
PARNUM parameter
PCB
general description
macro
parameter
Peripheral device hardware codes
Physical
command block
control block
request termination
Physical 1/0
coding
error processing
general description
macros
EXCP
PCB
operation
overlap
program
request termination
restrictions
POSITN macro
Post code for Control Language
POST macro
Priority
Processing considerations
end conditions
multi-volume files
priority
request overlap
5-2:7-34
1-22
7-3,4
7-30
— 7-30,32
4-1:7-3 thru
10,12 thru 15,
21,23,32 thru
36;B-4
7-7,8
7-31
7-13
7-24
7-24.28
7-3,4
7-34
7-22
7-7
7-3,4
5-2:7-34
23;B-22
-
NN > 0
с
WN —
Ww
NO —
7-36
5-1;7-1,32;
B-31
3-3
3-3
3-4
3-3
3-3
PURGE macro
Random access
READ macro
Reading data from //PAR cards
Read //PAR card
Records:
fixed length
variable length
RECSIZ parameter
Relative files
Release disc file space
Report of status
REQADR parameter
REQCNT parameter
Request
overlap
termination
Reset exception conditions
RESET macro
Retrieve
system date
time of day
Return file label information
RETURN parameter
Returned information format
REWIND parameter
RPOST macro
SDATE macro
SECONDS parameter
SEEK parameter
Sense information
Sequential
access
files
Service request mechanism
complete bit
CONTROL
end flag
error flag
function code
instruction
length
linkage
return code
return information
Index-5
3-3;6-1;7-1,
2,5;B-11
2-1
3-2,3:7-1,
3-4
7-21
3-2,3,4;
7-1,21
7-37
7-37
7-9
4-1:7-3 thru
10,12 thru 15,
21,23,32 thru
36:B-4
7-16
7-7,8
5-1;7-1,32;
B-31
7-1,37;B-38
7-31
7- 13
NN e
a N
Co 9 19 da + de & à = ©
ооо
Set up message format
SETCOM macro
SETIF macro
Sharing
an EXCP
a PCB
SIZERR parameter
SKIP parameter
Space element
Space management
general description
macros
ALLOC
EXPND
PURGE
SPREAD parameter
Standard system suffixes
STATUS macro
Status word
data channel
disc channel
STRIP parameter
Suspend program execution
7-38
5-1:7-1,
33:B-31
5-1:7-1,36;
B-34
4-23
4-1,2
7-24
7-24,28
2-3,8;
A-3,A-6
3-3
7-1,2,3;
B-6
7-1,2,5;
B-9
7-1,2,5;
B-11
7-34
B-4
3-2:7-1,15;
B-17
7-19
7-20
7-34
7-31
Tables
FDT
EDT
Tape labels
volume
file
Terminate program
TIME macro
TYPE macro
UNORD parameter
USAGE parameter
Variable length records
VERIFY parameter
Volume element
Volume label
disc
tape
Wait for service request
completion
WAIT macro
WRITE macro
Write message on SYSOUT
Writing to SYSOUT file
Index-6
2-12,13 thru
19:3-4:7-2
2-12,20 thru
34
.
CSA SS. GEESE eed weeks Ar Satie GEIS EONS EEE SEND Gel TEE MENS SS rE o MS SSE Sei EU o E DA seam SE ES SSL eral SEE o E PAE o EU E dean TEE SEE GEENA Geum ee Stel smal E VAAN dewalt CU Green venir UU SEE SEE cea Z——]
COMMENTS FORM
MR X/0S Control! Program and Data Management Services
| Extended Reference Manual (2200.002) | |
Please send us your comments, to help us produce better publications. Use the space below to
qualify your responses to the following questions, if you wish, or to comment on other aspects of
the publication. Please use specific page and paragraph/line references where appropriate. All
comments become the property of the Memorex Corporation.
Yes No
9 Is the material:
Easy to understand? ..... 22444 4 44 4 4 4 4 4 4 4 e e 4 О O
Conveniently organized? ..... 4444 4 444 64 0 4 4 4 4 40 a О
Complete? . . . .. .. e 20m rare ana e aaa О O
Well illustrated? . . . . . . . . e... remar ree O O
Accurate? . . . 24224 4 4 4 4 4 4 0 4 0 4 0 4 4 ae a a O
Suitable for its intended audience? . . . . . . . . . e. e... aa D O
Adequately indexed? . .. .......... 2 4 4 4 4 4 140 a О
e For what purpose did you use this publication? (reference, general interest, etc.)
e Please state your department's function:
e Please check specific criticism(s), give page number(s), and explain below:
Clarification on page(s)
Addition on page(s)
Deletion on page(s)
o daga
Error on page(s)
First Class
Permit No. 14831
Minneapolis,
Minnesota 55427
= Business Reply Mail
Мн. ЧЩ
№ Postage Necessary if Mailed in the United States
O Postage Will Be Paid By
J Memorex Corporation
Midwest Operations — Publications
8941 Tenth Avenue North
Minneapolis, Minnesota 55427
# ® 4 4 ныне ван в N 3 & & 8 BE 4 & & = 4 на г та ва ва и & ® # 4 ® BE EW 8 & WN a4 = a4 ® = 4 & ®8 WW OW 48 ня 8 BB a a. a. a ® wu =
Thank you for your information. .........
Our goal is to provide better, more useful manuals, and your
comments will help us to do so.
ee eee. Memorex Publications
">
/
Lejupielādēt
Tikai draudzīgs atgādinājums. Jūs varat apskatīt dokumentu tieši šeit. Bet pats galvenais, mūsu AI to jau ir izlasījis. Tas var izskaidrot sarežģītas lietas vienkāršiem vārdiem, atbildēt uz jūsu jautājumiem jebkurā valodā un palīdzēt ātri orientēties pat garākajos vai sarežģītākajos dokumentos.
Reklāma