Compaq ALPHASERVER DS10 Reference Manual
PDF
Hati
Tangazo
Tangazo
AlphaServer DS10
Console Reference
Order Number: EK–DS10S–CR. B01
This manual describes the general operations of the AlphaServer
DS10 system. It presents the SRM console (the command-line
interface for Tru64 UNIX and OpenVMS operating systems),
AlphaBIOS (the graphics interface for Windows NT and Linux),
and remote console management.
Compaq Computer Corporation
Notice
The information in this publication is subject to change without notice.
COMPAQ COMPUTER CORPORATION SHALL NOT BE LIABLE FOR TECHNICAL OR
EDITORIAL ERRORS OR OMISSIONS CONTAINED HEREIN, NOR FOR INCIDENTAL
OR CONSEQUENTIAL DAMAGES RESULTING FROM THE FURNISHING,
PERFORMANCE, OR USE OF THIS MATERIAL. THIS INFORMATION IS PROVIDED
“AS IS” AND COMPAQ COMPUTER CORPORATION DISCLAIMS ANY WARRANTIES,
EXPRESS, IMPLIED OR STATUTORY AND EXPRESSLY DISCLAIMS THE IMPLIED
WARRANTIES OF MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE,
GOOD TITLE AND AGAINST INFRINGEMENT.
This publication contains information protected by copyright. No part of this publication may be
photocopied or reproduced in any form without prior written consent from Compaq Computer
Corporation.
© 1999 Compaq Computer Corporation.
All rights reserved. Printed in the U.S.A.
The software described in this guide is furnished under a license agreement or nondisclosure
agreement. The software may be used or copied only in accordance with the terms of the
agreement.
Compaq, Deskpro, Fastart, Compaq Insight Manager, Systempro, Systempro/LT, ProLiant,
ROMPaq, QVision, SmartStart, NetFlex, QuickFind, PaqFax, ProSignia, registered United
States Patent and Trademark Office.
Netelligent, Systempro/XL, SoftPaq, QuickBlank, QuickLock are trademarks and/or service
marks of Compaq Computer Corporation.
Linux is a registered trademark of Linus Torvalds in serveral countries. Microsoft, Windows,
and Windows NT are registered trademarks of Microsoft Corporation.
Other product names mentioned herein may be trademarks and/or registered trademarks of their
respective companies.
Warning!
This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Achtung!
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb
dieses Gerätes Rundfunkstörungen auftreten, in welchen Fällen der Benutzer für
entsprechende Gegenmaßnahmen verantwortlich ist.
Attention!
Ceci est un produit de Classe A. Dans un environnement domestique, ce produit risque de
créer des interférences radioélectriques, il appartiendra alors à l’utilisateur de prendre les
mesures spécifiques appropriées.
This equipment generates, uses, and may emit radio frequency energy. The equipment has
been type tested and found to comply with the limits for a Class A digital device pursuant to
Part 15 of FCC rules, which are designed to provide reasonable protection against such radio
frequency interference.
Operation of this equipment in a residential area may cause interference in which case the
user at his own expense will be required to take whatever measures may be required to
correct the interference.
Any modifications to this device - unless expressly approved by the manufacturer - can void
the user’s authority to operate this equipment under part 15 of the FCC rules.
Contents
Preface
Chapter 1
1.1
1.2
1.3
1.3.1
1.3.2
1.4
1.5
1.5.1
1.5.2
1.5.3
1.6
1.7
1.8
1.9
1.9.1
1.9.2
1.10
1.10.1
1.10.2
1.10.3
1.10.4
1.10.5
1.11
1.11.1
1.11.2
1.11.3
1.12
1.13
xiii
Operations
Powering Up the System
Power-Up Display
Booting Tru64 UNIX
Booting from a Local Disk
Booting from a Remote Disk
Installing Tru64 UNIX
Booting OpenVMS
Booting OpenVMS from a Local Disk
Booting OpenVMS from a Disk on a Cluster
Booting OpenVMS from a Remote Disk
Installing OpenVMS
Booting Windows NT
Installing Windows NT
Switching Between Operating Systems
Switching to Windows NT
Switching to Tru64 UNIX or OpenVMS
Updating Firmware
Updating Firmware from the CD-ROM
Updating Firmware from Floppy Disks
Performing the Update from Floppy Disks
Updating Firmware from a Network Device
LFU Commands
Hard Disk Partitioning for Windows NT
Hard Disk Error Conditions
System Partitions
How AlphaBIOS Works with System Partitions
Using the Halt Button
Halt Assertion
1-2
1-4
1-6
1-6
1-8
1-10
1-12
1-12
1-14
1-16
1-18
1-20
1-22
1-24
1-24
1-25
1-26
1-28
1-32
1-34
1-38
1-41
1-44
1-44
1-46
1-47
1-48
1-51
v
Chapter 2
2.1
2.2
2.2.1
2.2.2
2.2.3
2.3
2.3.1
2.3.2
2.3.3
2.3.4
2.3.5
2.3.6
2.4
2.5
2.6
2.7
2.8
2.8.1
2.8.2
2.9
2.9.1
2.9.2
2.9.3
2.10
2.11
2.12
2.13
2.13.1
2.13.2
2.14
2.15
2.16
2.17
2.18
2.19
2.19.1
2.19.2
2.19.3
2.19.4
2.19.5
vi
SRM Console
Invoking the SRM Console
Commands
Command Summary
Commands: Syntax
Commands: Special Keystrokes and Characters
Show Commands
Show Config
Show Device
Show Memory
Show PAL
Show Power
Show Version
Creating a Power-Up Script
Booting the Operating System
Configuring a PCI NVRAM Module
Testing the System
Set Commands
Set Password
Set Secure
Secure Mode
Login Command and Secure Mode
Clear Password
Resetting the Password
Stopping and Starting CPU
Updating Firmware
Forcing a System Crash Dump
Using Environment Variables
Set envar
Show envar
Depositing and Examining Data
Reading a File
Initializing the System
Finding Help
Switching from SRM to AlphaBIOS Console
Environment Variable Summary
auto_action
bootdef_dev
boot_osflags
com1_baud
com1_mode
2-2
2-3
2-3
2-5
2-6
2-8
2-8
2-10
2-12
2-12
2-13
2-14
2-14
2-16
2-18
2-19
2-23
2-23
2-24
2-25
2-25
2-26
2-27
2-28
2-28
2-30
2-31
2-31
2-32
2-33
2-34
2-35
2-36
2-37
2-38
2-40
2-40
2-41
2-43
2-43
2.19.6
2.19.7
2.19.8
2.19.9
2.19.10
2.19.11
2.19.12
2.19.13
2.19.14
2.19.15
2.19.16
2.19.17
Chapter 3
3.1
3.2
3.3
3.3.1
3.3.2
3.3.3
3.3.4
3.3.5
3.3.6
3.3.7
3.4
3.5
3.5.1
3.5.2
3.6
3.7
3.8
3.9
3.9.1
3.9.2
3.10
3.11
3.11.1
3.11.2
console
ew*0_mode
ew*0_protocols
kbd_hardware_type
language
os_type
password
pci_parity
pk*0_fast
pk*0_host_id
pk*0_soft_term
tt_allow_login
2-44
2-45
2-45
2-46
2-46
2-47
2-47
2-48
2-48
2-49
2-49
2-50
AlphaBIOS Console
Starting AlphaBIOS
Keyboard Conventions and Help
System Configuration
Displaying the System Configuration
System Board Configuration
Hard Disk Configuration
PCI Configuration
SCSI Configuration
Memory Configuration
Integrated Peripherals
Updating Firmware
Setting Up the Hard Disk
Creating and Deleting Partitions Manually
Formatting a FAT Partition
Performing Setup Tasks
Installing Operating System
Selecting the Version of Windows NT
Designating a Primary Operating System
Selecting a Primary Operating System
Primary Operating System and the Auto Start Option
Switching from AlphaBIOS to SRM Console
Running Utility Programs
Running Utilities from a Graphics Monitor
Running Utilities from a Serial Terminal
3-2
3-4
3-6
3-6
3-8
3-10
3-12
3-15
3-17
3-18
3-19
3-21
3-24
3-26
3-28
3-32
3-34
3-36
3-36
3-38
3-42
3-44
3-45
3-46
vii
Chapter 4
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.14.1
4.14.2
4.14.3
4.14.4
4.14.5
4.14.6
4.14.7
4.14.8
4.14.9
4.14.10
4.14.11
4.14.12
4.14.13
4.14.14
4.14.15
4.14.16
4.14.17
4.14.18
4.14.19
4.14.20
4.14.21
4.14.22
4.14.23
4.14.24
viii
Remote Console Manager
RMC Components
Terminal Setup
Operating Modes
Entering the RMC
SRM Environment Variables for COM1
Status Monitoring
Remote Power (On/Off)
Remote Halt (In/Out)
Configuring Remote Dial-In
Configuring Dial-Out Alert
Dialing In
Resetting the RMC to Factory Defaults
Troubleshooting Tips
RMC Commands
clear alert
clear port
disable alert
disable remote
enable alert
enable remote
halt (in/out)
hangup
help or ?
power off
power on
quit
reset
send alert
set alert
set com1_mode
set dial
set escape
set init
set logout
set password
set user
set wdt
status
4-2
4-3
4-4
4-6
4-6
4-7
4-9
4-10
4-12
4-14
4-17
4-18
4-19
4-21
4-23
4-23
4-23
4-24
4-24
4-25
4-26
4-27
4-27
4-27
4-28
4-28
4-29
4-29
4-30
4-31
4-32
4-33
4-34
4-35
4-35
4-36
4-36
4-36
Appendix A
A.1
A.2
A.3
A.4
A.5
A.6
Setting Jumpers
Warnings and Cautions ........................................................................ A-2
Remove Power from the System ........................................................... A-3
Open the System ................................................................................... A-4
Remove the Floppy Disk Enclosure ...................................................... A-5
Set Jumpers .......................................................................................... A-6
Restore Power ....................................................................................... A-8
Examples
1–1
1–2
1–3
1–4
1–5
1–6
1–7
1–8
1–9
1–10
1–11
1–12
1–13
1–14
1–15
2–1
2–2
2–3
2–4
2–5
2–6
2–7
2–8
2–9
2–10
2–11
2–12
2–13
2–14
2–15
Power-Up Display ..................................................................................1-4
Booting Tru64 UNIX from a Local Disk ................................................1-6
Booting Tru64 UNIX from a Remote Disk .............................................1-8
Installing Tru64 UNIX.........................................................................1-10
Booting OpenVMS from a Local Disk ..................................................1-12
Booting OpenVMS from a Disk on a Cluster .......................................1-14
Booting OpenVMS from a Remote Disk...............................................1-16
Installing OpenVMS ............................................................................1-18
Starting LFU from the SRM Console...................................................1-26
Booting LFU from the CD-ROM ..........................................................1-27
Updating Firmware from the CD-ROM ...............................................1-28
Creating Update Diskettes on an OpenVMS System ..........................1-33
Updating Firmware from the Floppy Disk ..........................................1-34
Selecting DS10FW to Update Firmware from Internal Floppy Disk ....1-37
Updating Firmware from a Network Device........................................1-38
Show Config Command ..........................................................................2-8
Show Device Command........................................................................2-10
Show Memory Command .....................................................................2-12
Show PAL Command ...........................................................................2-12
Show Power Command ........................................................................2-13
Show Version Command ......................................................................2-14
Editing the nvram Script .....................................................................2-15
Clearing the nvram Script ...................................................................2-15
Boot Command.....................................................................................2-17
Prcache Command ...............................................................................2-18
Test Command .....................................................................................2-19
Set Password Command ......................................................................2-23
Set Secure Command ...........................................................................2-24
Secure Mode and Login Command ......................................................2-26
Clear Password Command...................................................................2-26
ix
2–16
2–17
2–18
2–19
2–20
2–21
2–22
2–23
2–24
2–25
2–26
4–1
4–2
Lfu Command.......................................................................................2-28
Crash Command ..................................................................................2-30
Setting and Showing Environment Variables......................................2-32
Creating a User-Defined Environment Variable .................................2-32
Deposit Command................................................................................2-33
Examine Command..............................................................................2-33
More Command....................................................................................2-34
Initialize Command..............................................................................2-35
Help Command ....................................................................................2-36
Switching to the AlphaBIOS Console ..................................................2-37
Changing Baud Rate ............................................................................2-43
Dial-In Configuration...........................................................................4-12
Dial-Out Alert Configuration...............................................................4-14
Figures
1–1
1–2
1–3
1–4
1–5
1–6
1–7
1–8
1–9
3–1
3–2
3–3
3–4
3–5
3–6
3–7
3–8
3–9
3–10
3–11
3–12
3–13
3–14
3–15
3–16
x
Check Power Setting ..............................................................................1-2
Location of Control Panel and On/Off Button........................................1-3
Physical Numbering for PCI Slots .........................................................1-4
AlphaBIOS Boot Screen .......................................................................1-20
Installing Windows NT ........................................................................1-22
Starting LFU from the AlphaBIOS Console .......................................1-26
System Partition Not Defined..............................................................1-47
Halt/Reset Button ................................................................................1-48
Halt/Reset Jumper ...............................................................................1-49
Boot Screen ............................................................................................3-2
AlphaBIOS Setup Screen .......................................................................3-3
Typical First-Level Help Screen ............................................................3-4
Second-Level Help Screen......................................................................3-5
Display System Configuration Screen ...................................................3-6
System Board Configuration..................................................................3-8
Hard Disk Configuration .....................................................................3-10
PCI Configuration ................................................................................3-12
PCI Slots ..............................................................................................3-13
Advanced PCI Information ..................................................................3-14
SCSI Configuration ..............................................................................3-15
Memory Configuration .........................................................................3-17
Integrated Peripherals.........................................................................3-18
Updating Firmware .............................................................................3-19
Hard Disk Setup Screen.......................................................................3-21
Create New Partition Dialog Box.........................................................3-24
3–17
3–18
3–19
3–20
3–21
3–22
3–23
3–24
3–25
3–26
3–27
3–28
4–1
4–2
4–3
4–4
4–5
4–6
4–7
A–1
A–2
A–3
A–4
A–5
Delete Partition Dialog Box .................................................................3-25
Formatting a FAT Partition.................................................................3-26
Standard Formatting ...........................................................................3-27
Standard CMOS Setup Screen.............................................................3-28
Advanced CMOS Setup Screen ............................................................3-30
Installing Windows NT ........................................................................3-32
Operating System Selections ...............................................................3-34
Primary Operating System ..................................................................3-36
Operating System Selection Setup.......................................................3-38
Switching to the SRM Console.............................................................3-42
Run Maintenance Program Dialog Box ...............................................3-44
AlphaBIOS Utilities Menu...................................................................3-45
Location of RMC Components on Motherboard .....................................4-2
Setups for RMC Mode ............................................................................4-3
Bypass Mode ..........................................................................................4-4
Power Button .........................................................................................4-9
Halt/Reset Jumper ...............................................................................4-10
Halt/Reset Button ................................................................................4-11
RMC Jumpers (Default Positions) .......................................................4-18
Removing Power from the System ........................................................ A-3
Opening the System Cabinet ................................................................ A-4
Removing the Floppy Disk Enclosure ................................................... A-5
Setting Jumpers on the Motherboard ................................................... A-6
Restoring Power .................................................................................... A-8
Tables
1
1–1
1–2
1–3
2–1
2–2
2–3
2–4
2–5
2–6
2–7
3–1
4–1
4–2
Documentation .......................................................................................xiv
Control Panel Functions ........................................................................1-3
File Locations for Creating Update Diskettes on a PC ........................1-32
LFU Command Summary....................................................................1-41
Summary of SRM Console Commands ..................................................2-3
Syntax for SRM Console Commands .....................................................2-5
Special Characters for SRM Console .....................................................2-6
Device Naming Convention..................................................................2-11
PCI Address Assignments....................................................................2-11
Environment Variable Summary.........................................................2-38
Settings for boot_osflags Bootflags (OpenVMS)...................................2-42
AlphaBIOS Option Key Mapping.........................................................3-46
SRM Environment Variables for COM1 ................................................4-6
Status Command Fields.........................................................................4-7
xi
4–3
4–4
4–5
A–1
xii
Halt/Reset Button Function under Operating Systems.......................4-11
Elements of Dial String and Alert String ............................................4-16
RMC Troubleshooting ..........................................................................4-19
Jumpers and Factory Default Positions................................................ A-7
Preface
Intended Audience
This manual is for anyone who manages, operates, or services an AlphaServer
DS10 system.
Document Structure
This manual uses a structured documentation design. Topics are organized into
small sections for efficient reference. Each topic begins with an abstract. You
can quickly gain a comprehensive overview by reading only the abstracts. Next
is an illustration, table, or example, also providing quick reference. Last in the
structure are descriptive text and syntax definitions.
This manual has four chapters, one appendix, and an index:
•
Chapter 1, Operations, provides basic operating instructions, including
powering up the system, booting, and operating system installation.
•
Chapter 2, SRM Console, presents the command-line interface that
supports the Tru64 UNIX and OpenVMS operating systems. (NT uses the
SRM test command, only.) The SRM console is used to bootstrap the
operating system, configure and test the system hardware, examine system
options for errors, and set or change environment variables.
•
Chapter 3, AlphaBIOS Console, details the graphical interface that
supports the Microsoft Windows NT operating system and some utility
programs. This chapter explains how to perform common system
management tasks with AlphaBIOS.
•
Chapter 4, Remote Management Console, describes how to manage the
system from a remote location.
•
Appendix A, Setting System Jumpers, describes how to check and reset
if necessary the Halt/Reset select jumper and remote management console
jumper.
xiii
Conventions
In examples of SRM console output, commands the user enters are presented in
boldface type, while the system’s output is in regular type. Comments on the
examples are either called out with circled numbers (➊➋➌) or are preceded by a
pound sign (#) and are given in boldface italics.
Documentation Titles
This lists the AlphaServer DS10 documentation.
Table 1 AlphaServer DS10 Documentation
Title
Order No.
Console Reference Guide
EK-DS10S-CR
Rackmount Guide
EK-DS10S-RM
Maintenance/Service Guide
AK-DS10S-MS
Safety Booklet
296382-021
User Reference Card
EK-DS10S-UR
Quick Setup Poster
EK-DS10S-CP
xiv
Chapter 1
Operations
This chapter provides basic operating instructions, including powering up the
system, booting, and operating system installation. Note that your choice of
operating system has already been installed at the factory; this information is
provided so that should you decide to change operating systems, you may. It
also provides information about updating firmware.
Sections in this chapter are:
•
Powering Up the System
•
Power-Up Display
•
Booting Tru64 UNIX
•
Installing Tru64 UNIX
•
Booting Open VMS
•
Installing OpenVMS
•
Booting Windows NT
•
Installing Windows NT
•
Switching Between Operating Systems
•
Updating Firmware
•
Hard Disk Partitioning for Windows NT
•
Using the Halt Button
•
Halt Assertion
Operations 1-1
1.1
Powering Up the System
To power up the system, check your power setting (see Figure 1–
1). Then press the On/Off button to the On position (Figure 1–2).
The button is in the lower right hand corner of the front of the
system. Check the control panel LEDs.
Figure 1–1 Check Power Setting
115V
230V
PK1047a
1-2
DS10 Console Reference
Figure 1–2 Location of Control Panel and On/Off Button
PK1043b
Table 1–1 Control Panel Functions
Symbol
Function
Halt button. Under OpenVMS and Tru64 UNIX, suspends the operating
system and returns control to the SRM console. Under Windows NT, this
button initiates a system reset.
Environmental amber LED. On indicates Temperature or Fan LEDs are
on. Flashes when operating system invokes it as an alert.
Temperature amber LED. On indicates internal temperature exceeds
operating conditions. The system shuts down 30 seconds after this LED
lights.
Fan amber LED. On indicates that at least one of the three fans in the
system has failed. The system shuts down 30 seconds after this LED lights.
Disk Activity green LED. Flashes when internal system disks are
accessed.
Power Present green LED. On when power is present in the system.
Power button. Push in to start the system and connect power. Push again
to remove power and stop the system.
Operations 1-3
1.2
Power-Up Display
Testing begins after pressing the On/Off button, and screen text
similar to that in Example 1–1 displays (if the console terminal is
a serial terminal connected to the COM1 port), along with status
messages in the control panel display. If the console terminal is
a graphics monitor, only the last few lines of the power-up
display print.
Example 1–1 Power-Up Display
1IKSJW]WXIQQIQSV] ➊
TVSFMRKLSWI4'TVSFMRK4'-XS-7%FVMHKIFYW➋
TVSFMRK4'-XS4'-FVMHKIFYW➋
FYWWPSXI[E()&%2IX[SVO'SRXVSPPIV
FYWWPSXI[F()&%2IX[SVO'SRXVSPPIV
FYWWPSXHUE%GIV0EFW1'-()
FYWWPSXHUF%GIV0EFW1'-()
FYWWPSX➌ZKE()'4S[IV7XSVQ
FYW➍WPSXTOE2'6'
FYW➍WPSXTOF2'6'
FYW➍WPSXI[G()%%2IX[SVO'SRXVSPPIV
FYW➎WPSXTOG50SKMG-74
FYW➏WPSXHVE1]PI\(%'
8IWXMRKXLI7]WXIQ
8IWXMRKXLI(MWOWVIEHSRP]
"""➐
Figure 1–3 Physical Numbering for PCI Slots
PCI Slot 4
64 Bit
PCI Slot 3
64 Bit
PCI Slot 2
64 Bit
PCI Slot 1
32 Bit
PK1045-99
1-4
DS10 Console Reference
➊
➋
Memory size is determined.
➌
Power-up slot 14 corresponds to the bottom physical slot, slot 0. See Figure
1–3.
The PCI bridges and attendant buses (indicated as IODn by the console)
are probed and the devices are reported. I/O adapters are configured.
Slot Location
Physical Slot Number
Logical Slot Number
Top
3
17
Second from top
2
16
Second from bottom
1
15
Bottom
0
14
➍
These devices are behind bridge of the card in logical slot 15, physical slot
1, second from the bottom.
➎
➏
➐
This device in is logical slot 16, physical slot 3.
Logical slot 17 is physical slot 4, the top slot.
The SRM console banner and prompt (>>>) are printed.
The SRM console is a command-line interface you use to set or read system
parameters.
If the auto_action environment variable is set to boot or restart and the
os_type environment variable is set to unix or openvms, the Tru64 UNIX
or OpenVMS operating system boots.
If the system is running the Windows NT operating system (the os_type
environment variable is set to nt), the SRM console loads and starts the
AlphaBIOS console.
See Section 2.19 for information on environment variables. See Chapter 2
for SRM console, and Chapter 3 for AlphaBIOS information.
Operations 1-5
1.3
Booting Tru64 UNIX
Tru64 UNIX® can be booted from a local disk or a remote disk
through an Ethernet connection. Refer to the documentation
shipped with the operating system for booting instructions.
1.3.1
Booting from a Local Disk
Example 1–2 Booting Tru64 UNIX from a Local Disk
"""WLSHIZMGI➊
HOE(/%6>'&'%0=.➋
HOE(/%6>'&'%0=.
HOE(/%6>)*%&
HOF(/&6>'&'%0=.
HOF(/&6>(&'7
HOF(/&6>'&'%0=.
HOG(/'6>'&&%0=+
HOG(/'6>'&&%0=+
HUE(5%'()%
HVE(6%1IQFIV.&3(
HVE(6%1IQFIV.&3(
HZE(:%
I[E);%&&&%
I[F);&&&&&
I[G);'&'
TOE4/%7'7-&YW-(
"""FSSXJMPIZQYRM\JPEKWEHOG➌
FSSXHOGJMPIZQYRM\JPEKWE
FPSGOSJHOGMWEZEPMHFSSXFPSGO
VIEHMRKFPSGOWJVSQHOG
FSSXWXVETGSHIVIEHMR
FEWI!IIMQEKICWXEVX!MQEKICF]XIW!
MRMXMEPM^MRK,;64&EX
MRMXMEPM^MRKTEKIXEFPIEXJJJ
MRMXMEPM^MRKQEGLMRIWXEXI
WIXXMRKEJJMRMX]XSXLITVMQEV]'49
NYQTMRKXSFSSXWXVETGSHI
8VY92-<FSSX*VM%YK)(8
0SEHMRKZQYRM\
8LIW]WXIQMWVIEH]
8VY92-<:IVWMSR:)WEFPIRKTOSHIGGSQGSRWSPI
PSKMR
1-6
DS10 Console Reference
7XEVXMRK(IWOXST0SKMRSRHMWTPE]
;EMXJSVXLI(IWOXST0SKMRWGVIIRFIJSVIPSKKMRKMR➍
➊
The show device command displays device information, including
name and type of connection to the system. See Section 2.3.2 for a
description of the show device command and the device naming
convention.
➋
The operating system is on the third disk connected to the system
through the controller in slot 3 of the PCI. The name of this device,
dkc0, is used as an argument to the boot command.
➌
This command loads Tru64 UNIX from the disk dkc0, using the boot
file vmunix and autobooting to multiuser mode. See Section 2.5 for a
description of the boot command.
The boot command accepts the name of a boot device, a boot file
name through the -file option, and boot flags through the -flags
option. The environment variables bootdef_dev, boot_file, and
boot_osflags can also be used to specify the default boot device or
device list, the default boot file, and flag information. When an option
and the corresponding environment variable are both in a command
string, the option overrides the environment variable. The value of
the environment variable, however, is not changed. See Section 2.19
for information about environment variables.
➍
The operating system banner displays.
Operations 1-7
1.3.2
Booting from a Remote Disk
Example 1–3 Booting Tru64 UNIX from a Remote Disk
"""WLS[HIZMGI➊
I[E);%&)'➋
"""
"""FSSXJPEKWERTVSXSGSPWFSSXTI[E➌
FSSXI[EJPEKWER
&YMPHMRK*69XEFPI
8V]MRK&3384FSSX
&VSEHGEWXMRK&33846IUYIWX
6IGIMZIH&33844EGOIX*MPI2EQIZEVEHQVMWVMWEPTLELZQYRM\
PSGEPMRIXEHHVIWW
VIQSXIMRIXEHHVIWW
8*846IEH*MPI2EQIZEVEHQVMWVMWEPTLELZQYRM\
FSSXWXVETGSHIVIEHMR
FEWI!MQEKICWXEVX!MQEKICF]XIW!EJE
MRMXMEPM^MRK,;64&EX
MRMXMEPM^MRKTEKIXEFPIEXJ
MRMXMEPM^MRKQEGLMRIWXEXI
WIXXMRKEJJMRMX]XSXLITVMQEV]'49
NYQTMRKXSFSSXWXVETGSHI
7IGSRHEV]FSSXTVSKVEQ8LY%YK)78
0SEHMRKZQYRM\
8LIW]WXIQMWVIEH]
8VY92-<:IVWMSR:)WEFPIRKTOSHIGGSQGSRWSPI➍
1-8
DS10 Console Reference
➊
The show device command displays device information, including
name and type of connection to the system. See Section 2.3.2 for a
description of the show device command and the device naming
convention.
➋
The operating system is on a remote disk accessed through the
Ethernet controller in slot 4 of the PCI. The name of this device,
ewa0, is used as an argument to the boot command.
➌
This command loads Tru64 UNIX from ewa0, autobooting to
multiuser mode. See Section 2.5 for a description of the boot
command.
The boot command accepts the name of a boot device, a boot file
name through the -file option, and boot flags through the -flags
option. The environment variables bootdef_dev, boot_file, and
boot_osflags can also be used to specify the default boot device or
device list, the default boot file, and flag information. When an option
and the corresponding environment variable are both in a command
string, the option overrides the environment variable. The value of
the environment variable, however, is not changed. See Section 2.19
for information about environment variables.
➍
The operating system banner displays.
Operations 1-9
1.4
Installing Tru64 UNIX
Tru64 UNIX is installed from the CD-ROM. Refer to the
documentation shipped with the CD-ROM for installation
instructions.
Example 1–4 Installing Tru64 UNIX
"""WLS[HIZMGI
HOE(/%66(➊
"""
"""FSSXHOE➊
FSSXHOEJPEKW%
FPSGOSJHOEMWEZEPMHFSSXFPSGO
VIEHMRKFPSGOWJVSQHOE
FSSXWXVETGSHIVIEHMR
FEWI!IIMQEKICWXEVX!MQEKICF]XIW!
MRMXMEPM^MRK,;64&EX
MRMXMEPM^MRKTEKIXEFPIEXJJJ
MRMXMEPM^MRKQEGLMRIWXEXI
WIXXMRKEJJMRMX]XSXLITVMQEV]'49
NYQTMRKXSFSSXWXVETGSHI
8VY92-<FSSX8LY.YP)(8
0SEHMRKZQYRM\
-2-87-2+0)97)613()
-RMXMEPM^MRKW]WXIQJSV8VY92-<MRWXEPPEXMSR4PIEWI[EMX
4IVJSVQMRK'(631-RWXEPPEXMSR
0SEHMRKMRWXEPPEXMSRTVSGIWWERHWGERRMRKW]WXIQLEVH[EVI
?8LIl;IPGSQIXSXLI8VY92-<-RWXEPPEXMSR4VSGIHYVIzETTIEVWA➋
1-10 DS10 Console Reference
➊
Use the boot command to install the operating system from the CDROM, which is either dka500 or dqa0.
➋
See your operating system documentation for further installation
instructions.
Operations 1-11
1.5
Booting OpenVMS
OpenVMS can be booted from a local disk, a disk connected
through a cluster, or a remote disk through an Ethernet
connection. Refer to the documentation shipped with the
operating system for booting instructions.
1.5.1
Booting OpenVMS from a Local Disk
Example 1–5 Booting OpenVMS from a Local Disk
"""WLS[HIZMGI➊
HOE(/%6>'&'%0=.
"""
"""WLS[FSSXCVIWIX➋
FSSXCVIWIX
32
"""WLS[FSSXHIJCHIZ➌
FSSXHIJCHIZ HOE
"""FSSX➍
FSSXHOEJPEKW
FPSGOSJHOEMWEZEPMHFSSXFPSGO
VIEHMRKFPSGOWJVSQHOE
FSSXWXVETGSHIVIEHMR
FEWI!JEMQEKICWXEVX!MQEKICF]XIW!JE
MRMXMEPM^MRK,;64&EX
MRMXMEPM^MRKTEKIXEFPIEXJJJ
MRMXMEPM^MRKQEGLMRIWXEXI
WIXXMRKEJJMRMX]XSXLITVMQEV]'49
NYQTMRKXSFSSXWXVETGSHI
3TIR:1781%PTLE3TIVEXMRK7]WXIQ:IVWMSR
'ST]VMKLXG(MKMXEP)UYMTQIRX'SVTSVEXMSR%PPVMKLXWVIWIVZIH
78(6:-78%68943TIR:17WXEVXYTFIKYREX.90
17'403%(-'32*-+7'%2IREFPIHEYXSQEXMGHMWOWIVZMRK
Continued on next page
1-12 DS10 Console Reference
Example 1–5 Booting OpenVMS from a Local Disk (Continued)
8LI3TIR:17W]WXIQMWRS[I\IGYXMRKXLIWMXIWTIGMJMGWXEVXYTGSQQERHW
;IPGSQIXS3TIR:1781%PTLE3TIVEXMRK7]WXIQ:IVWMSR:➎
9WIVREQI
➊
The show device command displays device information. See Section
2.3.2 for a description of the show device command and the device
naming convention.
➋
The boot_reset environment variable was previously set to “on,”
causing the power-up trace to display when the system initializes (see
Section 1.2). See Section 2.19 for commands used with environment
variables.
➌
The bootdef_dev environment variable specifies the default boot
device. In this example, the default boot device was previously set to
dka200.2.0.7.1.
➍
No boot device is specified in the boot command; the default boot
device was set with the environment variable. See Section 2.5 for a
description of the boot command.
The boot command accepts the name of a boot device, a boot file
name through the -file option, and boot flags through the -flags
option. The environment variables bootdef_dev, boot_file, and
boot_osflags can also be used to specify the default boot device or
device list, the default boot file, and flag information. When an option
and the corresponding environment variable are both in a command
string, the option overrides the environment variable. The value of
the environment variable, however, is not changed. See Section 2.19
for information about environment variables.
➎
The operating system banner displays.
Operations 1-13
1.5.2
Booting OpenVMS from a Disk on a Cluster
Example 1–6 Booting OpenVMS from a Disk on a Cluster
"""WLS[FSSXHIJCHIZ➊
FSSXHIJCHIZHYE
"""WLS[HIZMGI➋
HYE(-%()2:)66*➌
"""FSSX➍
FSSXHYEJPEKW
&YMPHMRK*69XEFPI
;IPGSQIXS3TIR:17%PTLE813TIVEXMRK7]WXIQ:IVWMSR:➎
1-14 DS10 Console Reference
➊
The bootdef_dev environment variable specifies the default boot
device.
➋
The show device command displays device information, including
name and type of connection to the system. See Section 2.3.2 for a
description of the show device command and the device naming
convention.
➌
➍
The disk dua110.0.0.8.0is on the cluster that includes this system.
No boot device is specified in the boot command; the default boot
device was set with the environment variable. See Section 2.5 for a
description of the boot command.
The boot command accepts the name of a boot device, a boot file
name through the -file option, and boot flags through the -flags
option. The environment variables bootdef_dev, boot_file, and
boot_osflags can also be used to specify the default boot device or
device list, the default boot file, and flag information. When an option
and the corresponding environment variable are both in a command
string, the option overrides the environment variable. The value of
the environment variable, however, is not changed. See Section 2.19
for information about environment variables.
➎
The operating system banner prints.
Operations 1-15
1.5.3
Booting OpenVMS from a Remote Disk
Example 1–7 Booting OpenVMS from a Remote Disk
"""WLS[HIZMGI➊
I[E);%&)'➊
"""
"""FSSXI[EJPEKW➋
FSSXI[EJPEKW
&YMPHMRK*69XEFPI
8V]MRK134FSSX
2IX[SVOPSEHGSQTPIXI
;IPGSQIXS3TIR:17%PTLE813TIVEXMRK7]WXIQ:IVWMSR:➌
1-16 DS10 Console Reference
➊
The show device command displays device information, including
name and type of connection to the system. In this example the
Ethernet connection is ewa0. See Section 2.3.2 for a description of the
show device command and the device naming convention.
➋
The boot command specifies ewa0 as the boot device. See Section 2.5
for a description of the boot command.
The boot command accepts the name of a boot device, a boot file
name through the -file option, and boot flags through the -flags
option. The environment variables bootdef_dev, boot_file, and
boot_osflags can also be used to specify the default boot device or
device list, the default boot file, and flag information. When an option
and the corresponding environment variable are both in a command
string, the option overrides the environment variable. The value of
the environment variable, however, is not changed. See Section 2.19
for information about environment variables.
➌
The operating system banner prints.
Operations 1-17
1.6
Installing OpenVMS
OpenVMS is installed from the CD-ROM. Refer to the
documentation shipped with the OpenVMS kit for complete
installation instructions.
Example 1–8 Installing OpenVMS
"""FSSXJPEKWHOE➊
-RMXMEPM^MRK
7631:SRGTY
?8LIMRMXMEPM^EXMSRHMWTPE]TVMRXW7II7IGXMSRA
%PTLE7IVZIV(7'SRWSPI:\%46
'49FSSXMRK
FSSXHOEJPEKW
&YMPHMRK*69XEFPI
FPSGOSJHOEMWEZEPMHFSSXFPSGO
VIEHMRKFPSGOWJVSQHOE
FSSXWXVETGSHIVIEHMR
FEWI!MQEKICWXEVX!MQEKICF]XIW!H
MRMXMEPM^MRK,;64&EX
MRMXMEPM^MRKTEKIXEFPIEXJ
MRMXMEPM^MRKQEGLMRIWXEXI
WIXXMRKEJJMRMX]XSXLITVMQEV]'49
NYQTMRKXSFSSXWXVETGSHI
3TIR:1781%PTLE3TIVEXMRK7]WXIQ:IVWMSR\➋
714-7)'17+'49QIWWEKI4"""78%68
714-'49&338)('49LEWNSMRIHXLI46-1%6='49MRQYPXMTVSGIWWSVSTIVEXMSR
-RWXEPPMRKVIUYMVIHORS[RJMPIW
'SRJMKYVMRKHIZMGIW
=SYGERMRWXEPPSVYTKVEHIXLI3TIR:17%PTLESTIVEXMRKW]WXIQ
SV]SYGERMRWXEPPSVYTKVEHIPE]IVIHTVSHYGXWXLEXEVIMRGPYHIH
SRXLI3TIR:17%PTLESTIVEXMRKW]WXIQ'(631
=SYGEREPWSI\IGYXI('0GSQQERHWERHTVSGIHYVIWXSTIVJSVQ
WXERHEPSRIXEWOWWYGLEWFEGOMRKYTXLIW]WXIQHMWO
Continued on next page
1-18 DS10 Console Reference
Example 1–8 Installing OpenVMS (Continued)
4PIEWIGLSSWISRISJXLIJSPPS[MRK
-RWXEPPSVYTKVEHI3TIR:17%PTLE:IVWMSR\
0MWXPE]IVIHTVSHYGXOMXWXLEXXLMWTVSGIHYVIGERMRWXEPP
-RWXEPPSVYTKVEHIPE]IVIHTVSHYGXW
)\IGYXI('0GSQQERHWERHTVSGIHYVIW
7LYXHS[RXLMWW]WXIQ
)RXIV',3-')SV#XSVITIEXQIRY#
➊
Use the boot command to install the operating system from the CDROM, which is either dka500 or dqa0.
➋
See your operating system documentation for installation
instructions.
Operations 1-19
1.7
Booting Windows NT
Microsoft Windows NT is started from the AlphaBIOS Boot
screen.
Figure 1–4 AlphaBIOS Boot Screen
%PTLE&-377IXYT
(MWTPE]7]WXIQ
%PTLE&-379TKVEHI|
,EVH(MWO7IXYT|
'1377IXYT|
2IX[SVO7IXYT|
-RWXEPP3TIVEXMRK7]WXIQ
9XMPMXMIW
%FSYX%PTLE&-37|
8
4VIWW)28)6XSMRWXEPP;MRHS[W28
)7' !)\MX
1-20 DS10 Console Reference
*!,IPT
Two SRM environment variables must be set properly for Windows NT to boot.
The setting of the SRM os_type environment variable determines if AlphaBIOS
is loaded and started on reset and power-up. If os_type is set to nt, after the
power-up display the SRM console is loaded and started, and it then loads and
starts the AlphaBIOS console. AlphaBIOS must be running before Windows NT
can be booted. Windows NT requires a graphics monitor as its console. Setting
the SRM console environment variable to graphics and having a graphics
monitor attached to your system meets this requirement. After setting these
two variables, you have to power-down and power-up your system for them to
take effect.
The method used for booting Windows NT is determined by the setting of Auto
Start in the AlphaBIOS Standard CMOS Setup screen (see Chapter 3).
•
If Auto Start is enabled, the primary version of Windows NT starts
automatically.
•
If Auto Start is disabled, use the arrow keys to select the Windows NT
version to start. Press Enter to boot Windows NT.
NOTE: The SRM console environment variable must be set to graphics before
booting Windows NT, though this setting is not necessary to run
AlphaBIOS. At the SRM console prompt, >>>:
>>>WIXGSRWSPIKVETLMGW
The Halt/Reset jumper on the motherboard must be set to the Windows NT
position for the Halt button to operate (see Section 1.12). If the Halt/Reset
jumper is set in the OpenVMS/Tru64 UNIX position, the Halt button will be
ignored by the Windows NT operating system and have no effect. Properly set,
the Halt button will initiate a system reset.
Operations 1-21
1.8
Installing Windows NT
Windows NT is installed from the CD-ROM. Insert the CD-ROM
into the drive, start AlphaBIOS Setup, select the menu item
Install Windows NT, and follow the prompts.
Figure 1–5 Installing Windows NT
%PTLE&-377IXYT
(MWTPE]7]WXIQ
%PTLE&-379TKVEHI|
,EVH(MWO7IXYT|
'1377IXYT|
2IX[SVO7IXYT|
-RWXEPP;MRHS[W28
9XMPMXMIW
%FSYX%PTLE&-37|
*!,IPT
8
4VIWW)28)6XSMRWXEPP;MRHS[W28
)7' !)\MX
The Halt/Reset jumper on the motherboard must be set to the Windows NT
position for the Halt button to operate (see Section 1.12). If the Halt/Reset
jumper is set in the OpenVMS/Tru64 UNIX position, the Halt button will be
ignored by the Windows NT operating system and have no effect. Properly set,
the Halt button will initiate a system reset.
1-22 DS10 Console Reference
Windows NT requires a partitioned and formatted hard disk drive. If your
drive is not partitioned or formatted, follow the instructions in Section 3.5
before installing the Windows NT operating system.
Up to three versions of Windows NT can be resident in a system at one time.
If this is a new Windows NT installation, start with this procedure:
1. Use CMOS Setup to set the system date and time: start AlphaBIOS
Setup, select CMOS Setup, and press Enter.
2. Perform an express hard disk setup: return to the main AlphaBIOS Setup
screen, select Hard Disk Setup, and press Enter.
3.
Perform an express hard disk setup by pressing F7 to enter Express
Setup.
4.
Continue the setup by pressing the F10 key.
5.
Go to the procedure below.
This procedure is for all Windows NT installations:
1. Put the Windows NT CD into the CD-ROM drive.
2. Start AlphaBIOS Setup, select Install Windows NT, and press Enter.
Follow the prompts to complete the installation. For more information on
installing Windows NT, refer to the Installation Guide in your Windows NT
software package.
Operations 1-23
1.9
Switching Between Operating Systems
The system supports multiple operating systems on different
system and data disks not in the machine at the same time. That
is, you can have a set of disks for each operating system.
CAUTION: This operation is not for the faint hearted especially if you have a
shadow system disk and shadow arrays. The file structures of each
of the three operating systems are incompatible and therefore all
disks must be removed from the system and upon reinstallation
must be replaced in exactly the same physical locations. It is
therefore necessary to keep track of the location of each disk in the
system.
1.9.1
Switching to Windows NT
Use the following procedure:
1. Shut down the operating system and power off the system.
2. Remove and mark the physical location of each disk in the system.
3. Check your Halt/Reset jumper position (see Section 1.12).
4. Either place blank disks or your Windows NT disk set into the system. (If
you are placing a Windows NT disk set into the system, be sure that each
disk is replaced in the same physical location from which it was removed.)
5. Power on the system.
6. Enter the following commands at the SRM console prompt:
"""WIXSWCX]TIRX
"""MRMX
7. Either install Windows NT, see Section 1.8, or at the AlphaBIOS boot
screen, start AlphaBIOS setup (F2), select CMOS Setup, and press Enter.
8. Set the system date and time.
9. In CMOS Setup, check that the setup for the floppy and other basic
parameters is accurate. Set system-specific parameters, such as the
1-24 DS10 Console Reference
memory test and password, in Advanced CMOS Setup as needed. Press
F10 to save the changes.
10. From the AlphaBIOS Setup screen select Utilities. In the selection box,
choose OS Selection Setup. Make sure the selections (boot name, boot
file, and so on) are what you want. Press F10 to save the changes.
11. Return to the boot screen and boot Windows NT.
1.9.2
Switching to Tru64 UNIX or OpenVMS
Use the following procedure:
1. Shut down the operating system and power off the system.
2. Remove and mark the physical location of each disk in the system.
3. Either place blank disks or your Tru64 UNIX or OpenVMS disk set into the
system. No matter which disk set you are placing into the system, be
sure that each disk is placed in the same physical location from
which it was removed.
4. Power on the system.
5. In AlphaBIOS, access the Advanced CMOS Setup screen and change the
Console Selection to Tru64 UNIX or OpenVMS (both use SRM) as
appropriate. Press F10 to save the change. This menu selection changes
the os_type environment variable to either UNIX or VMS so that the SRM
console does not load AlphaBIOS but remains in the system when you reset
the system.
6. Press the Halt/Reset button to reset the system.
7. Either install Tru64 UNIX (see Section 1.4) or OpenVMS (see Section 1.6) or
boot the operating system.
Operations 1-25
1.10 Updating Firmware
Start the Loadable Firmware Update (LFU) utility by issuing the
lfu command at the SRM console prompt, booting it from the
CD-ROM while in the SRM console, or selecting Update
AlphaBIOS in the AlphaBIOS Setup screen.
Example 1–9 Starting LFU from the SRM Console
"""PJY
0SEHEFPI*MVQ[EVI9THEXI9XMPMX]
7IPIGXJMVQ[EVIPSEHHIZMGIGHEHZEI[ESV
4VIWW VIXYVR"XSF]TEWWPSEHMRKERHTVSGIIHXS0*9GHE
94("
Figure 1–6 Starting LFU from the AlphaBIOS Console
PK1461-98
1-26 DS10 Console Reference
Use the Loadable Firmware Update (LFU) utility to update system firmware.
You can start LFU from either the SRM console or the AlphaBIOS console.
•
From the SRM console, start LFU by issuing the lfu command (see
Example 1–9). Also from the SRM console, LFU can be booted from the
Alpha CD-ROM (V5.4 or later), as shown in Example 1–10.
•
From the AlphaBIOS console, select Update AlphaBIOS from the
AlphaBIOS Setup screen (see Figure 1–6).
A typical update procedure is:
1.
Start LFU.
2.
Use the LFU list command to show the revisions of modules that LFU can
update and the revisions of update firmware.
3.
Use the LFU update command to write the new firmware.
4.
Use the LFU exit command to go back to the console.
The sections that follow show examples of updating firmware from the local CDROM, the local floppy, and a network device.
Example 1–10 Booting LFU from the CD-ROM
"""WLS[HIZMGI
HOE(/%66(
"""FSSXHOE
FSSXHOEJPEKW
FPSGOSJHOEMWEZEPMHFSSXFPSGO
NYQTMRKXSFSSXWXVETGSHI
8LIHIJEYPXFSSXJMPIJSVXLMWTPEXJSVQMW
?(7A(7C0*9)<)
,MX 6)8962"EXXLITVSQTXXSYWIXLIHIJEYPXFSSXJMPI
&SSXJMPI '6"
7XEVXMRK*MVQ[EVI9THEXI9XMPMX]
0SEHEFPI*MVQ[EVI9THEXI9XMPMX]
94("
Operations 1-27
1.10.1
Updating Firmware from the CD-ROM
Insert the Alpha CD-ROM, start LFU, and select cda0 as the load
device.
Example 1–11 Updating Firmware from the CD-ROM
0SEHEFPI*MVQ[EVI9THEXI9XMPMX]
7IPIGXJMVQ[EVIPSEHHIZMGIGHEHZEI[ESV
4VIWW VIXYVR"XSF]TEWWPSEHMRKERHTVSGIIHXS0*9GHE➊
4PIEWIIRXIVXLIREQISJXLISTXMSRWJMVQ[EVIJMPIWPMWXSV
4VIWW VIXYVR"XSYWIXLIHIJEYPXJMPIREQI?(7*;A(7'4➋
'ST]MRK(7'4JVSQ(/%
'ST]MRK?(7A8'6)%(1)JVSQ(/%
'ST]MRK?(7A8'761631JVSQ(/%
'ST]MRK?(7A8'%6'631JVSQ(/%
*YRGXMSR(IWGVMTXMSR➌
(MWTPE](MWTPE]WXLIW]WXIQkWGSRJMKYVEXMSRXEFPI
)\MX(SRII\MX0*9VIWIX
0MWX0MWXWXLIHIZMGIVIZMWMSRJMVQ[EVIREQIERH
YTHEXIVIZMWMSR
0JY6IWXEVXW0*9
6IEHQI0MWXWMQTSVXERXVIPIEWIMRJSVQEXMSR
9THEXI6ITPEGIWGYVVIRXJMVQ[EVI[MXLPSEHEFPIHEXEMQEKI
:IVMJ]'SQTEVIWPSEHEFPIERHLEVH[EVIMQEKIW
#SV,IPT7GVSPPWXLMWJYRGXMSRXEFPI
94("
1-28 DS10 Console Reference
➊
Select the device from which firmware will be loaded. The choices are
the internal CD-ROM, the internal floppy disk, or a network device. In
Example 1–11, the internal CD-ROM is selected.
➋
Select the file that has the firmware update, or press Enter to select the
default file. The file options are:
DS10FW (default)
SRM console, AlphaBIOS console, and I/O adapter
firmware.
DS10CP
SRM console and AlphaBIOS console firmware
only.
DS10IO
I/O adapter firmware only.
In this example the file for console firmware (AlphaBIOS and SRM) is
selected.
➌
The LFU function table and prompt (UPD>) display.
Continued on next page
Operations 1-29
Example 1–11 Updating Firmware from the CD-ROM (Continued)
94("PMWX➍
(IZMGI'YVVIRX6IZMWMSR*MPIREQI9THEXI6IZMWMSR
*WF\JWFCJ[\
2XRXCJ[\\
4O\%O^TWECJ[%
7VQ\WVQCJ[\\
4YE%GMTGECJ[%\\
94("YTHEXI➎
;%62-2+YTHEXIWQE]XEOIWIZIVEPQMRYXIWXSGSQTPIXIJSVIEGLHIZMGI
'SRJMVQYTHEXISR%PTLE&-37?=2A]➏
(3238%&368
%PTLE&-379THEXMRKXS::IVMJ]MRK:4%77)(
'SRJMVQYTHEXISRWVQJPEWL?=2A]
(3238%&368
WVQJPEWL9THEXMRKXS::IVMJ]MRK:4%77)(
94("I\MX➐
1-30 DS10 Console Reference
➍
Use the LFU list command to determine the revision of firmware in a
device and the most recent revision of that firmware available in the
selected file. In this example, the resident firmware for each console
(SRM and AlphaBIOS) is at an earlier revision than the firmware in
the update file.
➎
The update command updates the device specified or all devices. In
this example, the wildcard indicates that all devices supported by the
selected update file will be updated.
➏
For each device, you are asked to confirm that you want to update the
firmware. The default is no. Once the update begins, do not abort the
operation. Doing so will corrupt the firmware on the module.
➐
The exit command returns you to the console from which you entered
LFU (either SRM or AlphaBIOS).
Operations 1-31
1.10.2
Updating Firmware from Floppy Disks
Create two update diskettes before starting LFU: one for console
updates and one for I/O. See Section 1.10.3 for an example of the
update procedure.
Table 1–2 File Locations for Creating Update Diskettes on a PC
Console Update Diskette
I/O Update Diskette
DS10FW.TXT
DS10IO.TXT
DS10CP.TXT
TCREADME.SYS
TCREADME.SYS
CIPCA315.SYS
TCSRMROM.SYS
DFPAA310.SYS
TCARCROM.SYS
KZPAAA11.SYS
1. Download the update files from the Internet.
2. On a PC, copy files onto two FAT-formatted diskettes as shown
in Table 1–2.
3. From an OpenVMS system, copy files onto two ODS2-formatted diskettes as
shown in Example 1–12.
1-32 DS10 Console Reference
Example 1–12 Creating Update Diskettes on an OpenVMS System
Console update diskette
MRUYMVIMKRSVI-RWIVXFPERO,(JPSTT]MR(:%XLIRGSRXMRYI
WIXZIVMJ]
WIXTVSGTVMZ!EPP
MRMXHIRWMX]!LHMRHI\!FIKMRHZEXGSHWGT
QSYRXHZEXGSHWGT
GVIEXIHMVIGXSV]HZE?HWA
GST]XGVIEHQIW]WHZE?HWAXGVIEHQIW]W
GST](7J[X\XHZE?HWAHWJ[X\X
GST](7GTX\XHZE?HWAHWGTX\X
GST]XGWVQVSQW]WHZE?HWAXGWVQVSQW]W
GST]XGEVGVSQW]WHZE?HWAXGEVGVSQW]W
HMWQSYRXHZE
WIXRSZIVMJ]
I\MX
I/O update diskette
MRUYMVIMKRSVI-RWIVXFPERO,(JPSTT]MR(:%XLIRGSRXMRYI
WIXZIVMJ]
WIXTVSGTVMZ!EPP
MRMXHIRWMX]!LHMRHI\!FIKMRHZEXGSHWMS
QSYRXHZEXGSHWMS
GVIEXIHMVIGXSV]HZE?HWA
GVIEXIHMVIGXSV]HZE?STXMSRWA
GST]XGVIEHQIW]WHZE?HWAXGVIEHQIW]W
GST](7J[X\XHZE?HWAHWJ[X\X
GST](7MSX\XHZE?HWAHWMSX\X
GST]GMTGEW]WHZE?STXMSRWAGMTGEW]W
GST]HJTEEW]WHZE?STXMSRWAHJTEEW]W
GST]O^TWE%W]WHZE?STXMSRWAO^TWEEW]W
HMWQSYRXHZE
WIXRSZIVMJ]
I\MX
Operations 1-33
1.10.3
Performing the Update from Floppy Disks
Insert an update diskette (see Section 1.10.2) into the floppy
drive. Start LFU and select dva0 as the load device.
Example 1–13 Updating Firmware from the Floppy Disk
0SEHEFPI*MVQ[EVI9THEXI9XMPMX]
7IPIGXJMVQ[EVIPSEHHIZMGIGHEHZEI[ESV
4VIWW VIXYVR"XSF]TEWWPSEHMRKERHTVSGIIHXS0*9HZE➊
4PIEWIIRXIVXLIREQISJXLISTXMSRWJMVQ[EVIJMPIWPMWXSV
4VIWW VIXYVR"XSYWIXLIHIJEYPXJMPIREQI?(7-3(7'4A(7-3➋
'ST]MRK(7-3JVSQ(:%
'ST]MRK8'6)%(1)JVSQ(:%
'ST]MRK'-4'%JVSQ(:%
'ST]MRK(*4%%JVSQ(:%
'ST]MRK/>47%%JVSQ(:%
?8LIJYRGXMSRXEFPIHMWTPE]WJSPPS[IHF]XLI94("TVSQTXEW
WLS[RMR)\EQTPIrA
94("PMWX➌
(IZMGI'YVVIRX6IZMWMSR*MPIREQI9THEXI6IZMWMSR
*WF\
JWFCJ[\
2X
RXCJ[\\
4O\%
O^TWECJ[%
7VQ\
WVQCJ[\\
4YE%
GMTGECJ[%\\
Continued on next page
1-34 DS10 Console Reference
➊
Select the device from which firmware will be loaded. The choices are
the internal CD-ROM, the internal floppy disk, or a network device.
In this example, the internal floppy disk is selected.
➋
Select the file that has the firmware update, or press Enter to select
the default file. When the internal floppy disk is the load device, the
file options are:
DS10CP (default)
SRM console and AlphaBIOS console firmware
only.
DS10IO
I/O adapter firmware only.
The default option in Example 1–11 (DS10FW) is not available, since
the file is too large to fit on a 1.44 MB diskette. This means that when
a floppy disk is the load device, you can update either console
firmware or I/O adapter firmware, but not both in the same LFU
session. If you need to update both, after finishing the first update,
restart LFU with the lfu command and insert the diskette with the
other file.
In this example the file for I/O adapter firmware is selected.
➌
Use the LFU list command to determine the revision of firmware in a
device and the most recent revision of that firmware available in the
selected file. In this example, the update revision for console firmware
displays as “Missing file” because only the I/O firmware files are
available on the floppy disk.
Operations 1-35
Example 1–13 Updating Firmware from the Floppy Disk (Continued)
94("YTHEXITJM➍
;%62-2+YTHEXIWQE]XEOIWIZIVEPQMRYXIWXSGSQTPIXIJSVIEGLHIZMGI
'SRJMVQYTHEXISRTJM?=2A]➎
(3238%&368
TJM9THEXMRKXS:IVMJ]MRKXS4%77)(
94("PJY➏
0SEHEFPI*MVQ[EVI9THEXI9XMPMX]
7IPIGXJMVQ[EVIPSEHHIZMGIGHEHZEI[ESV
4VIWW VIXYVR"XSF]TEWWPSEHMRKERHTVSGIIHXS0*9HZE
4PIEWIIRXIVXLIREQISJXLISTXMSRWJMVQ[EVIJMPIWPMWXSV
4VIWW VIXYVR"XSYWIXLIHIJEYPXJMPIREQI?(7-3(7'4A➐
8LIJYRGXMSRXEFPIHMWTPE]WJSPPS[IHF]XLI94("TVSQTX
'SRWSPIJMVQ[EVIGERRS[FIYTHEXIH
94("I\MX➑
1-36 DS10 Console Reference
➍
The update command updates the device specified or all devices.
➎
For each device, you are asked to confirm that you want to update the
firmware. The default is no. Once the update begins, do not abort the
operation. Doing so will corrupt the firmware on the module.
➏
The lfu command restarts the utility so that console firmware can be
updated. (Another method is shown in Example 1–14, where the user
specifies the file DS10FW and is prompted to insert the second
diskette.)
➐
The default update file, DS10CP, is selected. The console firmware
can now be updated, using the same procedure as for the I/O
firmware.
➑
The exit command returns you to the console from which you entered
LFU (either SRM or AlphaBIOS).
Example 1–14 Selecting DS10FW to Update Firmware from the
Internal Floppy Disk
"""PJY
0SEHEFPI*MVQ[EVI9THEXI9XMPMX]
7IPIGXJMVQ[EVIPSEHHIZMGIGHEHZEI[ESV
4VIWW VIXYVR"XSF]TEWWPSEHMRKERHTVSGIIHXS0*9HZE
4PIEWIIRXIVXLIREQISJXLIJMVQ[EVIJMPIWPMWXSV
4VIWW VIXYVR"XSYWIXLIHIJEYPXJMPIREQI?(7-3(7'4A(7J[
'ST]MRK(7*;JVSQ(:%
'ST]MRK8'6)%(1)JVSQ(:%
'ST]MRK8'761631JVSQ(:%
'ST]MRK8'%6'631JVSQ(:%
'ST]MRK'-4'%JVSQ(:%
4PIEWIMRWIVXRI\XJPSTT]GSRXEMRMRKXLIJMVQ[EVI
4VIWW VIXYVR"[LIRVIEH]3VX]TI(32)XSEFSVX
'ST]MRK'-4'%JVSQ(:%
'ST]MRK(*4%%JVSQ(:%
'ST]MRK/>47%%JVSQ(:%
Operations 1-37
1.10.4
Updating Firmware from a Network Device
Copy files to the local MOP server’s MOP load area, start LFU,
and select ewa0 as the load device.
Example 1–15 Updating Firmware from a Network Device
0SEHEFPI*MVQ[EVI9THEXI9XMPMX]
7IPIGXJMVQ[EVIPSEHHIZMGIGHEHZEI[ESV
4VIWW VIXYVR"XSF]TEWWPSEHMRKERHTVSGIIHXS0*9I[E➊
4PIEWIIRXIVXLIREQISJXLISTXMSRWJMVQ[EVIJMPIWPMWXSV
4VIWW VIXYVR"XSYWIXLIHIJEYPXJMPIREQI?(7*;A➋
'ST]MRK(7*;JVSQ);%
'ST]MRK8'6)%(1)JVSQ);%
'ST]MRK8'761631JVSQ);%
'ST]MRK8'%6'631JVSQ);%
'ST]MRK'-4'%JVSQ);%
'ST]MRK(*4%%JVSQ);%
'ST]MRK/>47%%JVSQ);%
?8LIJYRGXMSRXEFPIHMWTPE]WJSPPS[IHF]XLI94("TVSQTXEW
WLS[RMR)\EQTPIrA
94("PMWX➌
(IZMGI'YVVIRX6IZMWMSR*MPIREQI9THEXI6IZMWMSR
*WF\
JWFCJ[\
2X
RXCJ[\\
4O\%
O^TWECJ[%
7VQ\
WVQCJ[\\
4YE%
GMTGECJ[%\\
Continued on next page
1-38 DS10 Console Reference
Before starting LFU, download the update files from the Internet. You will
need the files with the extension .SYS. Copy these files to your local MOP
server’s MOP load area.
➊
Select the device from which firmware will be loaded. The choices are
the CD-ROM, the internal floppy disk, or a network device. In this
example, a network device is selected.
➋
Select the file that has the firmware update, or press Enter to select
the default file. The file options are:
DS10FW (default)
SRM console, AlphaBIOS console, and I/O
adapter firmware.
DS10CP
SRM console and AlphaBIOS console firmware
only.
DS10IO
I/O adapter firmware only.
In this example the default file, which has both console firmware
(AlphaBIOS and SRM) and I/O adapter firmware, is selected.
➌
Use the LFU list command to determine the revision of firmware in a
device and the most recent revision of that firmware available in the
selected file. In this example, the resident firmware for each console
(SRM and AlphaBIOS) and I/O adapter is at an earlier revision than
the firmware in the update file.
Continued on next page
Operations 1-39
Example 1–15 Updating Firmware from a Network Device
(Continued)
94("YTHEXIEPP➍
;%62-2+YTHEXIWQE]XEOIWIZIVEPQMRYXIWXSGSQTPIXIJSVIEGLHIZMGI
(3238%&368
%PTLE&-379THEXMRKXS::IVMJ]MRK:4%77)(
(3238%&368
O^TWE9THEXMRKXS%:IVMJ]MRK%4%77)(
(3238%&368
O^TWE9THEXMRKXS%:IVMJ]MRK%4%77)(
(3238%&368
WVQJPEWL9THEXMRKXS::IVMJ]MRK:4%77)(
94("I\MX➎
➍
The update command updates the device specified or all devices. In
this example, the wildcard indicates that all devices supported by the
selected update file will be updated. Typically LFU requests
confirmation before updating each console’s or device’s firmware. The
-all option eliminates the update confirmation requests.
➎
The exit command returns you to the console from which you entered
LFU (either SRM or AlphaBIOS).
1-40 DS10 Console Reference
1.10.5
LFU Commands
The commands summarized in Table 1–3 are used to update
system firmware.
Table 1–3 LFU Command Summary
Command
display
exit
help
Function
Shows the physical configuration of the system.
Terminates the LFU program.
Displays the LFU command list.
lfu
Restarts the LFU program.
list
Displays the inventory of update firmware on the selected device.
readme
Lists release notes for the LFU program.
update
Writes new firmware to the module.
verify
Reads the firmware from the module into memory and compares
it with the update firmware.
display
The display command shows the physical configuration of the system. Display
is equivalent to issuing the SRM console command show configuration.
Because it shows the slot for each module, display can help you identify the
location of a device.
exit
The exit command terminates the LFU program, causes system initialization
and testing, and returns the system to the console from which LFU was called.
Operations 1-41
help
The help (or ?) command displays the LFU command list, shown below.
*YRGXMSR(IWGVMTXMSR
(MWTPE](MWTPE]WXLIW]WXIQkWGSRJMKYVEXMSRXEFPI
)\MX(SRII\MX0*9VIWIX
0MWX0MWXWXLIHIZMGIVIZMWMSRJMVQ[EVIREQIERHYTHEXI
VIZMWMSR
0JY6IWXEVXW0*9
6IEHQI0MWXWMQTSVXERXVIPIEWIMRJSVQEXMSR
9THEXI6ITPEGIWGYVVIRXJMVQ[EVI[MXLPSEHEFPIHEXEMQEKI
:IVMJ]'SQTEVIWPSEHEFPIERHLEVH[EVIMQEKIW
#SV,IPT7GVSPPWXLMWJYRGXMSRXEFPI
lfu
The lfu command restarts the LFU program. This command is used when the
update files are on a floppy disk. The files for updating both console firmware
and I/O firmware are too large to fit on a 1.44 MB disk, so only one type of
firmware can be updated at a time. Restarting LFU enables you to specify
another update file.
list
The list command displays the inventory of update firmware on the CD-ROM,
network, or floppy. Only the devices listed at your terminal are supported for
firmware updates.
The list command shows three pieces of information for each device:
•
Current Revision — The revision of the device’s current firmware
•
Filename — The name of the file used to update that firmware
•
Update Revision — The revision of the firmware update image
readme
The readme command lists release notes for the LFU program.
1-42 DS10 Console Reference
update
The update command writes new firmware to the module. Then LFU
automatically verifies the update by reading the new firmware image from the
module into memory and comparing it with the source image.
To update more than one device, you may use a wildcard but not a list. For
example, update k* updates all devices with names beginning with k, and
update * updates all devices. When you do not specify a device name, LFU tries
to update all devices; it lists the selected devices to update and prompts before
devices are updated. (The default is no.) The -all option eliminates the update
confirmation requests, enabling the update to proceed without operator
intervention.
CAUTION: Never abort an update operation.
Aborting corrupts the firmware on the module.
verify
The verify command reads the firmware from the module into memory and
compares it with the update firmware. If a module already verified successfully
when you updated it, but later failed tests, you can use verify to tell whether
the firmware has become corrupted.
Operations 1-43
1.11 Hard Disk Partitioning for Windows NT
The recommended hard disk partition on the first hard disk in
your system is:
Partition 1 should be 6 megabytes less than the total size of
the drive, but no more than 4095 MB. This large partition holds
the operating system and the application and data files.
Partition 2 should be the remaining 6 megabytes. This small
partition holds only the few files necessary for your computer to
boot.
This arrangement provides two benefits:
•
AlphaBIOS requires that a boot partition be formatted with the FAT file
system. However, the Windows NT file system (NTFS) provides advantages
over FAT, such as additional security and more efficient use of disk space.
By keeping the FAT boot partition as small as possible, the maximum
amount of space is left available for use as an NTFS partition.
•
Most applications install themselves onto drive C by default. Although the
program installation drive is usually configurable by the user, many people
accept the default of drive C. By making the first partition large, drive C
becomes the larger drive. This arrangement makes program installation
easier and avoids time-consuming insufficient disk space mistakes.
1.11.1
Hard Disk Error Conditions
Disk Initialization Failed
When you start hard disk setup, if you receive an “Internal error occurred”
message, it means that a disk was found, but there was an error in
communicating with the disk. The likely conditions that can cause this error
are:
•
Incompatible or failed disk cables. You may not have the correct cable
installed, or the cable might have a broken lead or connector. Try another
cable known to be good.
•
Disk controller not configured. You may have to run a configuration utility
to set up your hard disk controller. Check your controller documentation.
1-44 DS10 Console Reference
•
Disk controller malfunction. Most controllers come with a diagnostic utility
to test controller functioning. If a controller error is found, call the
manufacturer for a replacement.
•
Improper SCSI termination. Many SCSI controllers require that the
terminating resistor packs be removed from all drives between the
controller and last drive. Only the controller itself, and the last drive
connected to the controller (the ends of the “chain”), should have
terminating resistor packs left on.
No Hard Disks Found
When you start hard disk setup, if you receive a “No hard drives were found
connected to your computer” message, it means that AlphaBIOS could not
locate a hard drive. The likely conditions that cause this error are:
•
Cable not connected to either the disk or controller. The cable may have
worked loose from the connector on the controller or disk drive. Check the
cable connections, making sure the cable connectors are fully seated.
•
No power to the drive. The power connector may have worked loose from the
receptacle on the drive, or the power cable itself may be malfunctioning.
Check the cable connections, making sure the cable connectors are fully
seated. Try connecting the drive to a different power connector.
•
Disk drive malfunction. The disk drive itself may be malfunctioning and not
responding to requests from the controller. If this is the problem, then it
would appear as though the disk were absent. Replace the drive with a
drive known to be good. If the known good drive is correctly detected, then
your hard drive is defective. Contact the manufacturer for a replacement.
No Partitions on Disk
If hard disk 0 does not have any partitions defined, then a message will appear
when you start hard disk setup, asking if you want to perform an express disk
setup. Express disk setup automatically creates the default disk partition
arrangement on hard disk 0.
For more information on express setup, see Chapter 3.
Operations 1-45
1.11.2
System Partitions
To install Windows NT, a system partition must be defined. If no system
partition is found, the user is asked to choose from the available FAT partitions.
The purpose of the system partition is twofold. First, it tells the Windows NT
installation program where to place the OS Loader and hardware support files.
Second, upon subsequent restarts of Windows NT, the system partition
definition tells AlphaBIOS where the OSLOADER.EXE file is so it can
successfully hand off control to the OS Loader and continue the boot process.
The system partition can be the same partition into which Windows NT is
installed, or it can be separate. However, the system partition must be
formatted with the FAT file system. Because the default recommended partition
arrangement on Alpha calls for the partition into which Windows NT is
installed to be an NTFS partition, the system partition will almost always be a
small FAT partition on the same disk onto which Windows NT is installed.
1-46 DS10 Console Reference
1.11.3
How AlphaBIOS Works with System Partitions
If you are installing Windows NT for the first time, AlphaBIOS will determine
that a system partition has not been defined when you select Install Windows
NT in the AlphaBIOS Setup screen (see Figure 1–7). When this occurs,
AlphaBIOS searches for all FAT partitions on the system. If only one FAT
partition exists, AlphaBIOS designates that FAT partition as the system
partition and continues with the Windows NT installation. If more than one
FAT partition exists on your system, AlphaBIOS displays the list of FAT
partitions from which you can choose the system partition. After choosing the
system partition, the installation process continues.
Figure 1–7 System Partition Not Defined
%PTLE&-377IXYT
(MWTPE]7]WXIQ'SRJMKYVEXMSR
9TKVEHI%PTLE&-37
,EVH(MWO7IXYT
2S7]WXIQ4EVXMXMSR
'137W
-RWXEP
9XMPMX =SYQYWXHIWMKREXIE*%8HMWOTEVXMXMSREWE7]WXIQ
4EVXMXMSR;MRHS[W28[MPPYWIXLI7]WXIQ4EVXMXMSR
%FSYX
XSWXSVIW]WXIQWTIGMJMGWXEVXYTJMPIW
4PIEWIWIPIGXETEVXMXMSREWXLI7]WXIQ4EVXMXMSR
7]WXIQ4EVXMXMSR
)28)6
!'SR
(MWO4EVXMXMSR
Ï
(MWO4EVXMXMSR
(MWO4EVXMXMSR
(MWO4EVXMXMSR
(MWO4EVXMXMSR
Operations 1-47
1.12 Using the Halt Button
Under OpenVMS and Tru64 UNIX, the halt button pauses the
operating system. Under Windows NT, the Halt button resets
the system, generating power-up tests and output to the console
terminal.
Figure 1–8 Halt/Reset Button
PK1043b
Figure 1–9 Halt/Reset Jumper
1
Setting for
OpenVMS
& Tru64 UNIX
1
Setting for
Windows NT
PK0246c
1-48 DS10 Console Reference
Use the Halt button to halt the Tru64 UNIX or OpenVMS operating system
when it hangs, clear the SRM console password (see Section 2.9.2), or force a
halt assertion (see Section 1.13). The Halt button operates like issuing an SRM
halt command.
Windows NT does not recognize a HALT, so the jumper on the motherboard is
set differently for Windows NT (see Figure 1–9). When the jumper is in the NT
setting, pressing the Halt button is like issuing an SRM initialize command—
the system goes through power-up tests (as shown in Section 1.2).
Your system is shipped with the halt/reset jumper set in the correct position for
your operating system. If you are installing Windows NT after you have
purchased your system, or if you are switching between Windows NT and other
operating systems, you must check your jumper, and possibly have it reset. See
Appendix A for resetting the jumper.
Using Halt to Shut Down the Operating System
You can use the Halt button if the Tru64 UNIX or OpenVMS operating system
hangs. Pressing the Halt button halts the operating system back to the SRM
console firmware. From the console, you can use the crash command to force a
crash dump at the operating system level. See Section 2.12 for an example.
The Windows NT operating system does not support halts on this system.
Pressing the Halt button during a Windows NT session will initiate a system
reset.
Using Halt to Clear the Console Password
The SRM console firmware allows you to set a password to prevent unauthorized access to the console. If you forget the password, the Halt button, with the
login command, lets you clear the password and regain control of the console.
Section 2.9.2 describes the procedure.
Operations 1-49
1.13 Halt Assertion
A halt assertion allows you to disable automatic boots of the
operating system so that you can perform tasks from the SRM
console.
Under certain conditions, you might want to force a “halt assertion.” A halt
assertion differs from a simple halt in that the SRM console “remembers” the
halt. The next time you power up, the system ignores the SRM power-up script
(nvram) and ignores any environment variables that you have set to cause an
automatic boot of the operating system. The SRM console displays this
message:
,EPXEWWIVXMSRHIXIGXIH
2:6%1TS[IVYTWGVMTXRSXI\IGYXIH
%983C%'8-32!&3386)78%68ERH37C8=4)!28MKRSVIHMJETTPMGEFPI
Halt assertion is useful for disabling automatic boots of the operating system
when you want to perform tasks from the SRM console. It is also useful for
disabling the SRM power-up script if you have accidentally inserted a command
in the script that will cause a system problem. These conditions are described
in the sections “Disabling Autoboot” and “Disabling the SRM Power-Up Script.”
You can force a halt assertion using the Halt button, the RCM halt command,
or the RMC haltin command. Observe the following guidelines for forcing a
halt assertion.
Halt Assertion with Halt Button or RMC Halt Command
Press the Halt button on the local system (or enter the RMC halt command
from a remote system) approximately five seconds after starting power up or
when the SRM console is running. The system halts at the SRM console, and
the halt status is saved. The next time the system powers up, the saved halt
status is checked.
NOTE: Wait 5 seconds after the system begins powering up before pressing the
Halt button or remotely entering the RMC halt command. Press the
button for several seconds.
1-50 DS10 Console Reference
Halt Assertion with RMC Haltin Command
Enter the RMC haltin command at any time except during power-up. For
example, enter haltin during an operating system session or when the
AlphaBIOS console is running.
If you enter the RMC haltin command during a Tru64 UNIX or OpenVMS
session, the system halts back to the SRM console, and the halt status is saved.
The next time the system powers up, the saved halt status is checked.
If you enter the RMC haltin command when Windows NT or AlphaBIOS is
running, the interrupt is ignored. However, you can enter the RMC haltin
command followed by the RMC reset command to force a halt assertion. Upon
reset, the system powers up to the SRM console, but the SRM console does not
load the AlphaBIOS console.
Clearing a Halt Assertion
Clear a halt assertion as follows:
•
If the halt assertion was caused by pressing the Halt button or remotely
entering the RMC halt command, the console uses the halt assertion once,
then clears it.
•
If entering the RMC haltin command caused the halt assertion, enter the
RMC haltout command or cycle power on the local system.
Disabling Autoboot
The system automatically boots the selected operating system at power-up or
reset if the following environment variables are set:
•
For Tru64 UNIX and OpenVMS, the SRM environment variables os_type,
auto_action, bootdef_dev, boot_file, and boot_osflags
•
For Windows NT, the SRM os_type environment variable and the Auto
Start selection in the AlphaBIOS Standard CMOS Setup screen
You might want to prevent the system from autobooting so you can perform
tasks from the SRM console. Use one of the methods described previously to
force a halt assertion. When the SRM console prompt is displayed, you can enter
commands to configure or test the system. Chapter 2 describes the SRM
console commands and environment variables.
Operations 1-51
Disabling the SRM Power-Up Script
The system has a power-up script (file) named “nvram” that runs every time the
system powers up. If you accidentally insert a command in the script that will
cause a system problem, disable the script by using one of the methods described
previously to force a halt assertion. When the SRM console prompt is displayed,
edit the script to delete the offending command. See Section 2.4 for more
information on editing the nvram script.
1-52 DS10 Console Reference
Chapter 2
SRM Console
The SRM console is the command-line interface that supports the Tru64 UNIX
and OpenVMS operating systems. (Windows NT uses the SRM test command,
only.) The SRM console is used to bootstrap the operating system, configure
and test the system hardware, examine system options for errors, and set or
change environment variables.
This chapter describes the SRM commands and environment variables.
Sections in this chapter are:
•
Invoking the SRM Console
•
Updating Firmware
•
Commands
•
Forcing a System Crash Dump
•
Show Commands
•
Using Environment Variables
•
Creating a Power-Up Script
•
Depositing and Examining Data
•
Booting the Operating System
•
Reading a File
•
Configuring a PCI NVRAM
Module
•
Initializing the System
•
•
Finding Help
Testing the System
•
•
Set Commands
Switching from SRM to
AlphaBIOS Console
•
Secure Mode
•
•
Stopping and Starting CPU
Environment Variable
Summary
SRM Console
2-1
2.1
Invoking the SRM Console
When a system is powered up, the SRM console runs and either
remains running or passes control to another console or an
operating system. If the system is already running, invoke the
SRM console by shutting down the operating system or by
pressing the Halt button on the control panel.
If you are running Tru64 UNIX or OpenVMS Alpha operating system
To invoke the SRM console, do one of the following steps:
•
Shut down the operating system according to the procedure described in
your operating system documentation.
--or--
•
Press the Halt button on the control panel, if your system is running either
OpenVMS or Tru64 UNIX.
Following one of these steps, the console prompt, >>>, will be displayed. You
are now at the SRM console.
If you are running AlphaBIOS
To switch to the SRM console, do one of the following steps:
•
Select either OpenVMS console (SRM) or Tru64 UNIX console (SRM)
from the Console Selection in the Advanced CMOS Setup screen. Save
the setting by pressing the F10 key. Push the system Halt/Reset button to
start the SRM console.
--or--
•
Press the Halt/Reset button, wait 5 seconds, and then press the Halt button.
The SRM console will boot.
After you have performed tasks in the console mode, you must boot the
operating system with the boot command to go back to the operating mode.
2-2 DS10 Console Reference
2.2
Commands
This section presents a command summary (Table 2–1), Gives
the syntax for the console commands (Table 2–2), and explains
the special keystrokes and characters available in SRM console
mode (Table 2–3).
2.2.1
Command Summary
Table 2–1 Summary of SRM Console Commands
Command
alphabios
boot
clear envar
clear password
continue
crash
deposit
edit
examine
Function
Loads and starts the AlphaBIOS console.
Loads and starts the operating system.
Resets an environment variable to its default value.
Sets the password to zero.
Resumes program execution.
Forces a crash dump at the operating system level.
Writes data to the specified address.
Invokes the console line editor on a RAM file or on the
nvram file (power-up script).
Displays the contents of a memory location, register, or
device.
halt
Halts the specified processor. (Same as stop.)
help
Displays information about the specified console
command.
initialize
lfu
login
Resets the system to a known state.
Runs the Loadable Firmware Update Utility.
Turns off secure mode, enabling access to all SRM console
commands during the current session.
Continued on next page.
SRM Console
2-3
Table 2–1 Summary of SRM Console Commands (Continued)
Command
more
prcache
set envar
set host
set password
set secure
show envar
show config
show cpu
show device
show memory
show pal
show power
show version
stop
test
Function
Displays a file one screen at a time.
Utility that initializes and displays status of the
optional PCI NVRAM device.
Sets or modifies the value of an environment
variable.
Connects to an MSCP DUP server on a DSSI device.
Sets the console password for the first time or
changes an existing password.
Enables secure mode without requiring a restart of
the console.
Displays the state of the specified environment
variable.
Displays the configuration at the last system
initialization.
Displays the state of each processor in the system.
Displays a list of controllers and their devices in the
system.
Displays memory module information.
Displays the version of the privileged architecture
library code (PALcode).
Displays information about the power supply, system
and PCI fans, CPU fan, and temperature.
Displays the version of the console program.
Halts the processor. (Same as halt.)
Runs firmware diagnostics for the system.
2-4 DS10 Console Reference
2.2.2
Commands: Syntax
Table 2–2 Syntax for SRM Console Commands
Parameter
Length
Case
Abbreviation
Options
Numbers
Attribute or Action
Up to 255 characters, not including the terminating
carriage return or any characters deleted as the
command is entered. A command longer than 80
characters and without the backslash character (see
Table 2–3) causes display of an error message.
Upper- or lowercase characters can be used for input.
Characters are displayed in the case in which they are
entered.
Only by dropping characters from the end of words. You
must enter the minimum number of characters to
identify the keyword unambiguously. Abbreviation of
environment variables is allowed with the show
command.
You can use command options, to modify the
environment, after the command keyword or after any
symbol or number in the command. See individual
command descriptions for examples.
Most numbers in console commands are in decimal
notation. Two exceptions, both of which use hexadecimal
notation, are addresses and numbers used in the deposit
command. The default radix can be overridden by
inserting %d before numbers you want to express in
decimal, %b before binary, %o before octal, or %x before
hexadecimal. Register names (for example, R0) are not
considered numbers and use decimal notation.
No
characters
A command line with no characters is a null command.
The console program takes no action and does not issue
an error message; it returns the console prompt. The
console supports command line recall and editing.
Spaces or
tabs
Multiple adjacent spaces and tabs are compressed and
treated as a single space. The console program ignores
leading and trailing spaces.
SRM Console
2-5
2.2.3
Commands: Special Keystrokes and Characters
Table 2–3 Special Characters for SRM Console
Character
Return or
Enter
Backslash \
←Backspace
Delete
Help
Ctrl/A or F14
Ctrl/B or ↑
Function
Terminates a command line. No action is taken on a
command until it is terminated. If no characters are
entered and this key is pressed, the console just
redisplays the prompt.
Continues a command on the next line. Must be the last
character on the line to be continued.
Moves the cursor left one position, deleting one
character.
Deletes the previous character.
Entered at the console prompt without arguments, it
displays first-level help. When pressed after part of a
command, displays options available.
Toggles between insert and overstrike modes. The
default is overstrike.
Recalls previous command or commands. The last 16
commands are stored in the recall buffer.
Ctrl/C
Terminates the process that is running. Clears Ctrl/S;
resumes output suspended by Ctrl/O. When entered as
part of a command line, deletes the current line. Ctrl/C
has no effect as part of a binary data stream.
Ctrl/E
Moves the cursor to the end of the line.
Ctrl/F or →
Moves the cursor right one position.
Ctrl/H
Moves the cursor to the beginning of the line.
Ctrl/J
Deletes the previous word.
Continued next page.
2-6 DS10 Console Reference
Character
Ctrl/O
Function
Stops output to the console terminal for the current
command. Toggles between enable and disable. The output
can be reenabled by other means as well: when the console
prompts for a command, issues an error message, or enters
program mode, or when Ctrl/P is entered.
Ctrl/P
Halts the machine.
Ctrl/Q
Resumes output to the console terminal that was
suspended by Ctrl/S.
Ctrl/R
Redisplays the current line. Deleted characters are
omitted. This command is useful for hardcopy terminals.
Ctrl/S
Suspends output to the console terminal until Ctrl/Q is
entered. Cleared by Ctrl/C.
Ctrl/U
Deletes the current line.
*
"... "
#
Wildcarding for commands such as show.
Double quotes enable you to denote a string for
environment variable assignment.
Specifies that all text between it and the end of the line is a
comment. Control characters are not considered part of a
comment.
SRM Console
2-7
2.3
Show Commands
Several commands are used to display the system configuration:
show config, show cpu, show device, show memory, show
network, show pal, show power, and show version.
2.3.1
Show Config
The show config command displays a list of devices found on the
system interconnect and I/O buses. This is the configuration at
the most recent initialization.
Syntax:
show config
Example 2–1 Show Config Command
>>> show config
AlphaServer DS10 466 MHz
SRM Console:
PALcode:
Processors
CPU 0
V5X-XXX
OpenVMS PALcode V1.56-45, Tru64 UNIX PALcode V1.50-48
Alpha 21264-4 466 MHz
Bcache size: 2 MB
Core Logic
Cchip
Dchip
Pchip 0
DECchip 21272-CA Rev 2
DECchip 21272-DA Rev 2
DECchip 21272-EA Rev 2
TIG
Arbiter
Rev 2.1
Rev 3.30 (0x7E)
MEMORY
Array #
------0
Size
---------256 MB
SROM Revision: V1.8.208
Base Addr
--------000000000
Total Bad Pages = 0
Total Good Memory = 256 MBytes
PCI Hose 00
Bus 00
Slot 01: Acer Labs M1543C USB
Bus 00
Slot 03: Acer Labs M1543C PMU
Bus 00
Slot 07: Acer Labs M1543C
Bus 00
Slot 09: DE500-BA Network Controller
ewa0.0.0.9.0
Bridge to Bus 1, ISA
2-8 DS10 Console Reference
08-00-2B-86-1B-BA
Bus 00
Bus 00
Slot 11: DE500-BA Network Controller
ewb0.0.0.11.0
Slot 13: Acer Labs M1543C IDE
dqa.0.0.13.0
dqa1.1.0.13.0
Slot 14: DEC PowerStorm
Bus 00
Slot 15: DECchip 21152-AA
Bus 00
Slot 16: QLogic ISP1020
pkc0.6.0.16.0
dkc0.0.0.16.0
dkc200.2.0.16.0
Slot 17: Mylex DAC960
dra.0.0.17.0
dra0.0.0.17.0
dra1.0.0.17.0
dra2.0.0.17.0
dra3.0.0.17.0
Slot 00: NCR 53C875
pka0.7.0.2000.0
dka100.1.0.2000.0
dka300.3.0.2000.0
dka500.5.0.2000.0
Slot 01: NCR 53C875
pkb0.7.0.2001.0
dkb0.0.0.2001.0
dkb200.2.0.2001.0
dkb400.4.0.2001.0
Slot 02: DE500-AA Network Controller
ewc0.0.0.2002.0
Bus 00
08-00-2B-86-1B-BB
CD-532E
Bridge to Bus 2, PCI
Bus 00
Bus 02
Bus 02
Bus 02
ISA
Slot
0
Device
Name
Type
0
1
2
3
4
5
MOUSE
KBD
COM1
COM2
LPT1
FLOPPY
Embedded
Embedded
Embedded
Embedded
Embedded
Embedded
Enabled
Yes
Yes
Yes
Yes
Yes
Yes
SCSI Bus ID 6
RZ1CB-BA
RZ1CB-BA
1
1
1
1
Member
Member
Member
Member
JBOD
JBOD
JBOD
JBOD
SCSI Bus ID 7
RZ1CB-CA
RZ1CB-CA
RZ1EF-AB
SCSI Bus ID 7
RZ1CB-CA
RZ1DB-CS
RZ1CB-CA
00-06-2B-00-26-1C
BaseAddr
60
60
3f8
2f8
3bc
3f0
IRQ
DMA
12
1
4
3
7
6
2
>>>
SRM Console
2-9
2.3.2
Show Device
The show device command displays status for devices and
controllers in the system: SCSI and MSCP devices, the internal
floppy drive, and the network.
Syntax:
show device [controller_name]
controller_name
The controller name or abbreviation. When abbreviations
or wildcards are used, all controllers that match the type
are displayed. If no name is given, the display is a list of all
devices and controllers in the system.
Example 2–2 Show Device Command
>>> sho device
dka0.0.0.14.0
dka100.1.0.14.0
dqa0.0.0.13.0
dva0.0.0.0.0
ewa0.0.0.9.0
ewb0.0.0.11.0
pka0.7.0.14.0
>>>
DKA0
DKA100
DQA0
DVA0
EWA0
EWB0
PKA0
RZ2CA-KA N1H1
RZ2CA-KA N1H1
CD-532E- A 1.0A
08-00-2B-86-1F-71
08-00-2B-86-1F-70
SCSI Bus ID 7 5.57
An example of a device name is dka200.2.0.7.1. Table 2-4 shows the
interpretation of this device name.
2-10 DS10 Console Reference
Table 2–4 Device Naming Convention
dk
Category
Description
Driver ID
Two-letter designator of port or class driver
dk
SCSI disk
dq
ATAPI CD-ROM
mk
SCSI tape
dr
RAID set device
mu
DSSI tape
du
DSSI disk
pk
SCSI port
dv
Diskette drive
pu
DSSI port
ew
Ethernet port
fw
FDDI device
Storage adapter
ID
One-letter designator of storage adapter
(a, b, c...).
Device unit
number
Unique number (MSCP unit number). SCSI
unit numbers are forced to 100 X node ID.
2
Bus node number
Bus node ID.
0
Channel number
Used for multi-channel devices.
7
Logical slot
number
Corresponds to PCI slot number, as shown in
Table 2–5.
1
Hose number
0 — PCI 0
a
200
1 — PCI 1
Table 2–5 PCI Address Assignments
Physical
Slot #
Logical
Slot #
PCI
ID_SEL
Description/Position
3
17
AD 28
64-bit slot (top slot)
2
16
AD 27
64-bit slot (second from top)
1
15
AD 26
64-bit slot (second from bottom)
0
14
AD 25
32-bit slot (bottom slot)
SRM Console
2-11
2.3.3
Show Memory
The show memory command displays information about each
memory bank: slot number, size in megabytes, and the starting
address.
Syntax:
show memory
Example 2–3 Show Memory Command
>>> show memory
Array #
------0
1
2
3
Size
---------128 MB
128 MB
128 MB
128 MB
Base Addr
--------000000000
008000000
010000000
018000000
Total Bad Pages = 0
Total Good Memory = 512 MBytes
>>>
2.3.4
Show PAL
The show pal command displays the versions of Tru64 UNIX and
OpenVMS PALcode. PALcode is the Alpha Privileged
Architecture Library code, written to support Alpha processors.
It implements architecturally defined processor behavior.
Syntax:
show pal
Example 2–4 Show PAL Command
>>> show pal
pal OpenVMS PALcode V1.56-45, Tru64 UNIX PALcode V1.50-48
>>>
2-12 DS10 Console Reference
2.3.5
Show Power
The show power command displays status information about the
power supply, the system, PCI and CPU fans, and temperature.
This command is useful for displaying the error state of a Tru64
UNIX or OpenVMS system that shuts down because of a fan,
temperature, or power supply failure.
Syntax:
show power
If the system can be restarted, use this command. (If it cannot, use the RMC
status command. See Chapter 4.)
Example 2–5 Show Power Command
>>> show power
Power Supply
System Fan
PCI Fan
CPU Fan
Temperature
Status
good
good
good
good
good
Current ambient temperature is 34 degrees C
System shutdown temperature is set to 55 degrees C
2 Environmental events are logged in nvram
Do you want to view the events? (Y/<N>) y
Total Environmental Events: 2 (2 logged)
1
2
000
000
0
0
0:00
0:00
Temperature, Fans, Power Supplies Normal
Temperature, Fans, Power Supplies Normal
Do you want to clear all events from nvram? (Y/<N>) y
>>>
SRM Console
2-13
2.3.6
Show Version
The show version command displays the version of the SRM
console program that is installed on the system.
Syntax:
show version
Example 2–6 Show Version Command
>>> show version
version
>>>
2.4
V5.4-2 MAY 19 1999 14:24:16
Creating a Power-Up Script
A special nonvolatile file named “nvram” is stored in EEROM,
and is always invoked during the power-up sequence. You can
create an nvram script to include any commands you want the
system to execute at power-up. You alter, create and edit the
nvram script using the SRM edit command. With edit, lines can
be added, overwritten, or deleted.
Syntax:
edit file
where file is the name of the file to be edited.
The editing commands are:
Help
List
Renumber
Displays the brief help file.
Lists the current file prefixed with line numbers.
Renumbers the lines of the file in increments of 10.
Exit
Leaves the editor and closes the file, saving all changes.
Quit
Leaves the editor and closes the file without saving changes.
Nn
Nn text
Deletes line number nn.
Adds or overwrites line number nn with text.
2-14 DS10 Console Reference
NOTE: It is possible to disable the system by editing the nvram script. For
example, if you include the initialize command in the script, the
system will go into an endless loop. To fix this, press the Halt button
while the system is powering up. You can then edit the script to delete
the offending command.
Example 2–7 shows how to modify the user-created power-up script, “nvram.”
The pound sign (#) indicates explanatory comments. In this example the script
is edited to include a command that allows you to boot the Tru64 UNIX
operating system over the network.
Example 2–7 Editing the nvram Script
>>> edit nvram
editing ‘nvram’
0 bytes read in
*10 set ewa0_protocols bootp
*list
10 set ewa0_protocols bootp
*exit
27 bytes written out to nvram
>>> nvram
#Modify user power-up script, nvram.
#List current file with line numbers.
#Close file and save changes.
#Execute the script.
To clear the script, enter line numbers without any text. This deletes the lines.
See Example 2–8.
Example 2–8 Clearing the nvram Script
>>> edit nvram
editing ‘nvram’
20 bytes read in
*10
*exit
0 bytes written out to nvram
>>>
SRM Console
2-15
2.5
Booting the Operating System
The boot command is used to boot the operating system. The boot
command initializes the processor, loads a program image from
the specified boot device, and transfers control to that image.
Syntax: boot [-file filename] [-flags [value]] [-halt]
[-protocols enet_protocol] [boot_dev]
-file filename
The boot file.
-flags [value]
Specifies additional information to the loaded image or
operating system. In Tru64 UNIX, specifies boot flags.
In OpenVMS, specifies system root number and boot
flags. This qualifier overrides the setting of the
boot_osflags environment variable. See the
boot_osflags environment variable for a list of
settings and their meanings.
-halt
Forces the bootstrap operation to halt and invoke the
console program once the bootstrap image is loaded and
page tables and other data structures are set up.
Console device drivers are not shut down. Transfer
control to the image by entering the continue
command.
-protocols
enet_protocol
Either mop (default) or bootp. This qualifier overrides
the setting of the ew*0_protocols environment
variable.
boot_dev
A device path or list of devices from which the console
program attempts to boot, or a saved boot specification
in the form of an environment variable. This qualifier
overrides the setting of the bootdef_dev environment
variable. Use the bootdef_dev environment variable
to define the default boot device string.
2-16 DS10 Console Reference
Example 2–9 Boot Command
>>> b dkc0
(boot dkc0.0.0.16.0 -flags 0)
block 0 of dkc0.0.0.16.0 is a valid boot block
reading 898 blocks from dkc0.0.0.16.0
bootstrap code read in
base = 200000, image_start = 0, image_bytes = 70400
initializing HWRPB at 2000
initializing page table at ffb6000
initializing machine state
setting affinity to the primary CPU
jumping to bootstrap code
OpenVMS (TM) Alpha Operating System, Version V7.1-2
%SYSINIT-I- waiting to form or join an OpenVMS Cluster
%VMScluster-I-LOADSECDB, loading the cluster security database
%EWA0, Fast(100baseTX) mode set by console
%EWB0, Fast(100baseTX) mode set by console
. . .
%CNXMAN, Completing VMScluster state transition
$! Copyright (c) 1998 Digital Equipment Corporation. All rights reserved.
%STDRV-I-STARTUP, OpenVMS startup begun at 23-APR-1999 11:31:48.97
%MSCPLOAD-I-CONFIGSCAN, enabled automatic disk serving
. . .
The OpenVMS system is now executing the site-specific startup commands.
. . .
Welcome to OpenVMS (TM) Alpha Operating System, Version V7.1-2
Username:
SRM Console
2-17
2.6
Configuring a PCI NVRAM Module
The prcache command is used for system configuration to check
PCI NVRAM configuration information and battery status, to
clear data from the NVRAM module, and to set the date of the
next battery replacement. The command is used only with
Tru64 UNIX systems.
Syntax:
prcache -{f,z,b}
-f
Checks configuration information and battery status.
-z
Clears valid data; writes zeros to memory.
-b
Sets the date (month and year) for battery replacement.
Example 2–10 Prcache Command
>>> prcache -f
PCI NVRAM Disk Cache: passed
Size:
2MB
PCI Memory Address: 40000000
System ID: 12000000
State: - not valid
Battery Status: good (Charging)
Battery Disconnect Circuit Status: enabled
>>> prcache -z
This command will zero the PCI NVRAM Disk Cache
Do you really want to continue [Y/N] ? : y
clearing disk cache
>>>
2-18 DS10 Console Reference
2.7
Testing the System
The test command runs console-based exercisers for devices in
the system. Ctrl/C can abort testing.
test [-t time] [-q] [option]
Syntax:
-t time
-q
NOTE:
Specifies the run time in seconds. The default for system test is
120 seconds (2 minutes).
Disables the display of status messages as exerciser processes
are started and stopped during testing. Sets the environment
variable d_verbose to zero.
If you are running the Microsoft Windows NT operating system, switch from
AlphaBIOS to the SRM console in order to enter the test command. Select
Tru64 UNIX Console (SRM) or OpenVMS Console (SRM) from the
Advanced CMOS Setup of the AlphaBIOS console screen, save the setting by
pressing the F10 key, and then reset the system.
Example 2–11 Test Command
>>> test
environment variable t_cnt created
System test, runtime 150 seconds
Type ^C if you wish to abort testing once it has started
Default zone extended at the expense of memzone.
Use INIT before booting
Testing Ethernet device(s)
Testing VGA
Testing Memory
Testing IDE/ATAPI disks (read-only)
Testing SCSI disks (read-only)
Testing DKA* devices (read-only)..
No other SCSI disks to test
Testing floppy drive (dva0, read-only)
No diskette present, skipping floppy test
SRM Console
2-19
ID
Program
-------- -----------00001ae5
memtest
310378496
00001aea
memtest
306184192
00001b07
memtest
310378496
00001b54
exer_kid
215040
00001b74
exer_kid
8732672
00001b7b
exer_kid
8732672
ID
Program
-------- -----------00001ae5
memtest
549453824
00001aea
memtest
545259520
00001b07
memtest
545259520
00001b54
exer_kid
421888
00001b74
exer_kid
14434304
00001b7b
exer_kid
14434304
ID
Program
-------- -----------00001ae5
memtest
780140544
00001aea
memtest
780140544
00001b07
memtest
780140544
00001b54
exer_kid
631808
00001b74
exer_kid
20168704
00001b7b
exer_kid
20168704
ID
Program
-------- -----------00001ae5
memtest
1019215872
00001aea
memtest
1019215872
00001b07
memtest
1019215872
00001b54
exer_kid
835584
00001b74
exer_kid
27066368
Device
Pass Hard/Soft Bytes Written Bytes Read
------------ ------ --------- ------------- ----------memory
4
0
0
310378496
memory
4
0
0
306184192
memory
3
0
0
310378496
dqa0.0.0.13.
0
0
0
0
dka0.0.0.14.
0
0
0
0
dka100.1.0.1
0
0
0
0
Device
Pass Hard/Soft Bytes Written Bytes Read
------------ ------ --------- ------------- ----------memory
6
0
0
549453824
memory
6
0
0
545259520
memory
6
0
0
545259520
dqa0.0.0.13.
0
0
0
0
dka0.0.0.14.
0
0
0
0
dka100.1.0.1
0
0
0
0
Device
Pass Hard/Soft Bytes Written Bytes Read
------------ ------ --------- ------------- ----------memory
8
0
0
780140544
memory
8
0
0
780140544
memory
8
0
0
780140544
dqa0.0.0.13.
0
0
0
0
dka0.0.0.14.
0
0
0
0
dka100.1.0.1
0
0
0
0
Device
Pass Hard/Soft Bytes Written Bytes Read
------------ ------ --------- ------------- ----------memory
11
0
0
1019215872
memory
10
0
0
1019215872
memory
10
0
0
1019215872
dqa0.0.0.13.
0
0
0
0
dka0.0.0.14.
0
0
0
0
2-20 DS10 Console Reference
00001b7b
exer_kid dka100.1.0.1
0
0
0
0
27066368
ID
Program
Device
Pass Hard/Soft Bytes Written Bytes Read
-------- ------------ ------------ ------ --------- ------------- ----------00001ae5
memtest memory
13
0
0
1254096896
1254096896
00001aea
memtest memory
13
0
0
1249902592
1249902592
00001b07
memtest memory
12
0
0
1254096896
1254096896
00001b54
exer_kid dqa0.0.0.13.
0
0
0
0
1043456
00001b74
exer_kid dka0.0.0.14.
0
0
0
0
32800768
00001b7b
exer_kid dka100.1.0.1
0
0
0
0
32784384
ID
Program
Device
Pass Hard/Soft Bytes Written Bytes Read
-------- ------------ ------------ ------ --------- ------------- ----------00001ae5
memtest memory
15
0
0
1488977920
1488977920
00001aea
memtest memory
15
0
0
1484783616
1484783616
00001b07
memtest memory
14
0
0
1488977920
1488977920
00001b54
exer_kid dqa0.0.0.13.
0
0
0
0
1241088
00001b74
exer_kid dka0.0.0.14.
0
0
0
0
39665664
00001b7b
exer_kid dka100.1.0.1
0
0
0
0
39649280
ID
Program
Device
Pass Hard/Soft Bytes Written Bytes Read
-------- ------------ ------------ ------ --------- ------------- ----------00001ae5
memtest memory
17
0
0
1723858944
1723858944
00001aea
memtest memory
17
0
0
1723858944
1723858944
00001b07
memtest memory
16
0
0
1723858944
1723858944
00001b54
exer_kid dqa0.0.0.13.
0
0
0
0
1445888
00001b74
exer_kid dka0.0.0.14.
0
0
0
0
45350912
00001b7b
exer_kid dka100.1.0.1
0
0
0
0
45350912
Test time has expired...
System test complete
>>>
System test, runtime 1200 seconds
Type ^C if you wish to abort testing once it has started
SRM Console
2-21
Default zone extended at the expense of memzone.
Use INIT before booting
Testing Ethernet device(s)
Testing VGA
Testing Memory
Testing IDE/ATAPI disks (read-only)
Testing SCSI disks (read-only)
Testing floppy drive (dva0, read-only)
Test time has expired...
System test complete
>>>
2-22 DS10 Console Reference
2.8
2.8.1
Set Commands
Set Password
The set password command sets the console password for the
first time or changes an existing password. It is necessary to set
the password only if the system is going to operate in secure
mode.
Syntax:
set password
The password length must be between 15 and 30 alphanumeric characters.
If a password has not been set and the set password command is issued, the
console prompts for a password and verification.
If a password has been set and the set password command is issued, the
console prompts for the new password and verification, then prompts for the old
password. The password is unchanged if the validation password entered does
not match the existing password in the NVRAM.
Example 2–12 Set Password Command
>>> set password
# Password is not echoed.
Please enter the password:
Please enter the password again: # Validation is not echoed.
>>>
>>> set password
# Changing a password.
Please enter the password:
Please enter the password again:
Now enter the old password:
>>>
>>> set password
# Password entered is
Please enter the password:
# too short.
Password length must be between 15 and 30 characters
>>>
SRM Console
2-23
2.8.2
Set Secure
The set secure command enables secure mode without requiring
a restart of the console. If the password has been set, the console
will be secured and only a small subset of commands can be
performed. If a password has not been set, you are prompted to
do so.
Syntax:
set secure
Example 2–13 Set Secure Command
>>> set secure
# In this example a password
# has been set.
Console is secure. Please login.
>>> b dkb0
Console is secure - parameters are not allowed.
>>> login
Please enter the password:
# Password is not echoed.
>>> b dkb0
(boot dkb0.0.0.3.1)
.
.
>>> set secure
# Password has not been set.
Secure not set. Please set the password.
>>>
2-24 DS10 Console Reference
2.9
Secure Mode
When the console is in secure mode, the only commands
recognized are boot, login, continue, and start. Placing the console
in secure mode ensures that unauthorized persons cannot gain
access to the system. The commands for console security are set
password, clear password, and set secure. The login command
turns off security features during the current console session.
The boot command does not accept command line parameters in secure mode.
The console boots using the environment variables stored in NVRAM
(boot_file, bootdef_dev, boot_flags). After a successful boot, the console is
secured if there is a valid password.
The start and continue commands are valid on a secure console. After either
command is executed, the console is secured if there is a valid password. This
prevents an intruder from accessing the system.
2.9.1
Login Command and Secure Mode
The login command turns off the security features, enabling
access to all SRM console commands during the current session.
The system automatically returns to secure mode as soon as the
boot, continue, or start command is entered or when the system is
initialized.
When the login command is entered, the user is prompted for the current
system password. If a password has not been set, a message is displayed
indicating that there is no password in NVRAM. If a password has been set, this
prompt is displayed:
Please enter the password:
If the password entered matches the password in NVRAM when the prompt is
redisplayed, the console is no longer in secure mode and all console commands
can be performed.
NOTE:
If you enter the login command when a halt assertion exists, the
command fails, even if you enter the correct password. See Section 1.13
for information on halt assertion.
SRM Console
2-25
Example 2–14 Secure Mode and Login Command
>>> login
# System is not in secure mode.
>>>
Secure not set. Please set the password.
>>> login
Please enter the password:
>>>
# System is in secure mode.
# Password is not echoed.
>>> login
Please enter the password:
# System is in secure mode.
# Incorrect password is
# entered.
Invalid password
>>>
2.9.2
Clear Password
The clear password command clears the password environment
variable, setting it to zero. This command is used when you want
access to all the SRM console commands, but the system is in
secure mode. In order to use clear password, you must know the
current password.
To clear the password without knowing the current password, use the login
command, with the Halt button or RMC halt command, as described in the
section on the login command.
Example 2–15 Clear Password Command
>>> clear password
Please enter the password:
Password successfully cleared.
>>>
>>> clear password
Please enter the password:
Console is secure
>>>
2-26 DS10 Console Reference
# Password is not echoed.
# Invalid password entered.
2.9.3
Resetting the Password
If you have forgotten the current password, clear the password as follows:
From the Local Console Terminal
1. Enter the login command: >>> login
2. At the Enter Password: prompt, press the Halt button, then press the Return
key.
The password is now cleared and the console cannot be put into secure mode
unless a new password is set.
From the RMC
1. Enter the login command: >>> login
2. At the Enter Password: prompt, enter the RMC escape sequence.
3. At the RMC>>> prompt, enter the halt command and then the quit
command:
RMC>>> halt
RMC>>> quit
4. At the SRM console, clear the password:
>>> clear password
SRM Console
2-27
2.10 Stopping and Starting CPU
The halt (or stop) command stops program execution on a CPU
that is still running a booted program.
Syntax:
halt (or stop) 0
where 0 is the number of the CPU to halt.
For the DS10 system, this command has no effect because the single CPU is
halted when the system is at the console prompt.
2.11 Updating Firmware
The lfu command is used to update firmware from the SRM
console prompt. The lfu command starts the Loadable Firmware
Update (LFU) Utility.
The syntax is: lfu
Example 2–16 Lfu Command
>>> lfu
Checking dqa0.0.0.13.0 for the option firmware files. . .
Checking dva0 for the option firmware files. . .
Option firmware files were not found on CD or floppy.
If you want to load the options firmware,
please enter the device on which the files are located(ewa0),
or just hit <return> to proceed with a standard console update: dva0
Please enter the name of the options firmware files list, or
Hit <return> to use the default filename (ds10fw.txt) :
Copying ds10fw.txt from dva0. . .
Copying PC264NT.ROM from dva0. . .
Copying DS10SRM.ROM from dva0. . .
2-28 DS10 Console Reference
***** Loadable Firmware Update Utility *****
-----------------------------------------------------------------Function
Description
-----------------------------------------------------------------Display
Displays the system’s configuration table.
Exit
Done exit LFU (reset).
List
Lists the device, revision, firmware name, and update
revision.
Readme
Lists important release information.
Update
Replaces current firmware with loadable data image.
Verify
Compares loadable and hardware images.
? or Help
Scrolls this function table.
-----------------------------------------------------------------UPD> update *
Confirm update on:
nt
srm
[Y/(N)]y
WARNING: updates may take several minutes to complete for each device.
DO NOT ABORT!
nt
Updating to 5.69...
srm
Updating to 5.4-2...
Verifying 5.69...
PASSED.
Verifying 5.4-2...
PASSED.
UPD> exit
NOTE: If the system has been shut down from a booted program (most
commonly, the operating system) or in some other way halted back to
the SRM console, the system must be reset before running LFU.
See Chapter 1 for more information about LFU.
SRM Console
2-29
2.12 Forcing a System Crash Dump
The crash command forces a crash dump at the operating system
level (Tru64 UNIX or OpenVMS; has no effect on Windows NT).
This command is used when an error has caused the system to
hang and can be halted with the Halt button or the RMC halt
command. This command restarts the operating system and
forces a crash dump to the selected device.
Syntax:
crash [device]
where device is the name of the device to which the crash dump is written.
Example 2–17 Crash Command
>>> crash
CPU 0 restarting
DUMP: 401408 blocks available for dumping.
DUMP: 38535 required for a partial dump.
DUMP: 0x805001 is the primary swap with 401407, start our last 38534
: of dump at 362873, going to end (real end is one more, for
header)
DUMP.prom: dev SCSI 1 3 0 4 400 0 0, block 131072
DUMP: Header to 0x805001 at 401407 (0x61fff)
DUMP.prom: dev SCSI 1 3 0 4 400 0 0, block 131072
DUMP: Dump to 0x805001: ..................: End 0x805001
DUMP.prom: dev SCSI 1 3 0 4 400 0 0, block 131072
DUMP: Header to 0x805001 at 401407 (0x61fff)
succeeded
halted CPU 0
halt code = 5
HALT instruction executed
PC = fffffc00004e2d64
>>>
2-30 DS10 Console Reference
2.13 Using Environment Variables
Environment variables pass configuration information between
the console and the operating system. Their settings determine
how the system powers up, boots the operating system, and
operates.
You issue an init command to activate a new
environment variable.
Environment variables are set or changed with the set envar command (where
envar is a placeholder for the environment to be changed) and set to default
values with the set -default envar command. Their values are viewed with the
show envar command. User-defined nonvolatile environment variables are
created with the edit command described in Section 2.4. Section 2.19 describes
the environment variables in detail.
2.13.1
set envar
The set command sets or modifies the value of an environment
variable. It can also be used to create a new environment
variable if the name used is unique. Environment variables are
used to pass configuration information between the console and
the operating system. The setting of these variables determines
how the system powers up, boots the operating system, and
operates.
Syntax:
-default
set [-default] envar value
Restores an environment variable to its default setting.
envar
The name of the environment variable to be displayed. The
wildcard * displays all environment variables, which are:
console, kbd_hardware_type, language, ocp_text
and os_type
value
The new value of the environment variable.
Whenever you modify the value of any environment variables, the new value
takes effect only after you reset the system by pressing the Halt/Reset button or
issuing the initialize command.
SRM Console
2-31
2.13.2
show envar
The show envar command displays the current value (or setting)
of an environment variable.
show envar
Syntax:
envar
The name of the environment variable to be displayed. The
wildcard * displays all environment variables, which are:
console, kbd_hardware_type, language, ocp_text
and os_type.
Example 2–18 Setting and Showing Environment Variables
>>> show console
console
>>> set console serial
>>> show console
console
>>> init
graphics
serial
# The system must be init’ed for
the new parameters to take effect
Example 2–19 Creating a User-Defined Environment Variable
>>> edit nvram
editing ‘nvram’
0 bytes read in
*10 set mopv3_boot 1
*exit
17 bytes written out to nvram
>>>
In Example 2–19 the nvram script is edited so that an environment variable
called “mop3_boot” is created and set to 1 on each power-up. By default, MOP
boot sends four MOP V4 requests before defaulting to MOP V3. This usercreated environment variable forces the SRM console to bypass MOP V4
requests. This speeds up MOP booting on networks with MOP V3 software.
2-32 DS10 Console Reference
2.14 Depositing and Examining Data
Example 2–20 Deposit Command
>>> dep -b -n 1ff pmem:0 0
# Clear 1st 512 bytes of physical mem.
>>> d -l -n 3 vmem:1234 5
# Deposit 5 into four longwords starting
# at virtual memory address 1234.
>>> d -n 8 r0 ffffffff
# Load GPRs R0 through R8 with -1.
>>> d -l -n 10 -s 200 pmem:0 8
# Deposit 8 in the 1 longword of the
# first 17 pages in physical memory
>>> d -l pmem:0 0
# Deposit 0 to physical mem address 0.
>>> d + ff
# Deposit FF to physical mem address 4.
>>> d scbb 820000
# Deposit 820000 to SCBB.
st
Example 2–21 Examine Command
>>> examine pc
PC psr: 0 (
PC)
# Examine the program counter.
0000000000001170
>>> examine sp
gpr:
F0 (
R30)
# Examine the stack pointer.
0000000000072A60
>>> e -n 6 r4
grp: 20 (
R4) 0000000000005000
grp: 28 (
R5) 000000000FFFE000
grp: 30 (
R6) 00000003F8000C00
grp: 38 (
R7) 0000000053F761AE
grp: 40 (
R8) 0000010000000000
grp: 48 (
R9) 00000003F7800100
grp: 50 (
R10) 00000000000C7FFC
>>> examine pmem:400EC
pmem: 400EC A49D0078A47D0070
# Examine register R4 & the next 6 registers.
# Examine physical memory.
SRM Console
2-33
2.15 Reading a File
The more command displays a file one screen at a time.
Syntax:
more [file...]
where file is the name of the file to be displayed.
The more command is similar to that used in the MS-DOS and UNIX operating
systems. It is useful for displaying output that scrolls too quickly to be viewed.
For example, when you power up the system, the system startup messages
scroll, and the messages are logged to an event log
When the >>> prompt displays, you can use the more command to display the
contents of the event log file.
Example 2–22 More Command
>>> more el
# Display SRM console’s event log one screen at a time.
. . .
--More-- (SPACE - next page, ENTER - next line, Q - quit)
# Display online help one screen at a time.
>>> help * | more
. . .
--More-- (SPACE - next page, ENTER - next line, Q - quit)
2-34 DS10 Console Reference
2.16 Initializing the System
The initialize command resets the system and executes powerup tests.
Syntax:
initialize
After self-tests are executed, the system autoboots unless:
•
A halt assertion condition exists (see Section 1.13) –or–
•
The auto_action environment variable is set to halt (see Section 2.19.1).
If the auto_action environment variable is set to boot or restart and no halt
assertion condition exists, the system autoboots. In all other cases, the system
stops in console mode and does not attempt to boot.
Example 2–23 Initialize Command
>>> init
Initializing...
256 Meg of system memory
probing hose 0, PCI
probing PCI-to-ISA bridge, bus 1
probing PCI-to-PCI bridge, bus 2
bus 0, slot 9 -- ewa -- DE500-BA Network Controller
bus 0, slot 11 -- ewb -- DE500-BA Network Controller
bus 0, slot 13 -- dqa -- Acer Labs M1543C IDE
bus 0, slot 13 -- dqb -- Acer Labs M1543C IDE
bus 0, slot 14 -- vga -- DEC PowerStorm
bus 2, slot 0 -- pka -- NCR 53C875
bus 2, slot 1 -- pkb -- NCR 53C875
bus 2, slot 2 -- ewc -- DE500-AA Network Controller
bus 0, slot 16 -- pkc -- QLogic ISP1020
bus 0, slot 17 -- dra -- Mylex DAC960
Testing the System
Testing the Disks (read only)
Testing the Network
System Temperature is 34 degrees C
CPU 0
Alpha 21264-4 466 MHz
SROM Revision: V1.8.208
TIG
Rev 2.1
Arbiter
Rev 3.30 (0x7E)
Array #
Size
Base Addr
---------------- --------0
512 MB
000000000
1
512 MB
020000000
2
128 MB
050000000
3
256 MB
040000000
Total Bad Pages = 0
Total Good Memory = 1408 MBytes
AlphaServer DS10 466 MHz Console V5.4-2 MAY 19 1999 14:24:16
>>>
SRM Console
2-35
2.17 Finding Help
The help command displays basic information about the use of
console commands when the system is in console mode.
Syntax:
Command . . .
help [command . . . ]
Command or topic for which help is requested. The options are:
None
Displays the complete list of commands for
which you can receive help.
Command_name
Displays information about the console
command.
Argument_string
(such as “sh”)
Displays information about all commands
that begin with that string.
Example 2–24 Help Command
>>> help set
NAME
set
FUNCTION
Set an option or modify the value of an environment
variable.
SYNOPSIS
set <option> <value> or <envar> [-] <value>
where
<option>={host,mode}
where
<envar>={auto_action,bootdef_dev,boot_osflags,...}
[-default]
2-36 DS10 Console Reference
2.18 Switching from SRM to AlphaBIOS Console
The alphabios command loads and starts the AlphaBIOS console.
This is necessary for running AlphaBIOS-based utilities (such as
the RAID configuration utility). To switch from SRM to
AlphaBIOS, issue the alphabios command.
Syntax:
alphabios
To return to the SRM console:
•
If the os_type environment variable is set to unix or openvms, reset the
system by pressing the Halt/Reset button,--or--
•
If the os_type environment variable is set to nt, select Tru64 UNIX
console (SRM) or OpenVMS console (SRM) from the Advanced CMOS
Setup screen, save the setting by pressing key F10 and then reset the
system.
To switch permanently to the AlphaBIOS console:
If the permanent operating system is changed to Windows NT, you will want to
switch permanently to the AlphaBIOS console. To accomplish this:
1. Set the SRM os_type environment variable to nt.
2. Set the SRM console environment variable to graphics.
3. Reset the system with the initialize command, the Halt/Reset button, or by
power cycling.
Example 2–25 Switching to the AlphaBIOS Console
>>> alphabios
SRM Console
2-37
2.19 Environment Variable Summary
Environment variables pass configuration information between
the console and the operating system. Their settings determine
how the system powers up, boots the operating system, and
operates. Environment variables are set or changed with the set
envar command and returned to their default values with the
clear envar command. Their values are viewed with the show
envar command.
Table 2–6 lists the environment variables. Detailed descriptions follow. The
environment variables are specific to the SRM console.
Table 2–6 Environment Variable Summary
Environment Variable
auto_action
Function
Specifies the console’s action at power-up, a failure,
or a reset.
bootdef_dev
Specifies the default boot device string.
boot_osflags
Specifies the default operating system boot flags.
com*_baud
console
cpu_enabled
ew*0_mode
Changes the default baud rate of the COM1 or COM2
serial port.
Specifies the device on which power-up output is
displayed (serial terminal or graphics monitor).
Enables or disables a specific secondary CPU.
Specifies the connection type of the default Ethernet
controller.
ew*0_protocols
Specifies network protocols for booting over the
Ethernet controller.
kbd_hardware_
type
Specifies the default console keyboard type.
language
Specifies the console keyboard layout.
2-38 DS10 Console Reference
Table 2–6 Environment Variable Summary (Continued)
Environment Variable
ocp_text
os_type
Function
Overrides the default OCP display text with specified
text.
Specifies the operating system. Valid entries are:
openvms, unix, and nt.
password
A password stored in the NVRAM used to secure the
console.
pci_parity
Disables or enables parity checking on the PCI bus.
pk*0_fast
pk*0_host_id
pk*0_soft_term
tt_allow_login
Enables fast SCSI mode.
Specifies the default value for a controller host bus
node ID.
Enables or disables SCSI terminators on systems
that use the QLogic ISP1040 SCSI controller.
Enables or disables login to the SRM console
firmware on other console ports.
SRM Console
2-39
2.19.1
auto_action
Specifies the action the console takes any time the system
powers up, fails, or resets. When the setting involves autoboot,
the system boots from the default boot device specified by the
value of the bootdef_dev environment variable.
set auto_action value
Syntax:
where value can be:
halt
The system remains in console mode after power-up or a system
crash.
boot
The system boots automatically when it is turned on and halts after
a system failure.
restart
The system boots automatically when it is turned on or after it fails.
NOTE: If a halt assertion exists, the console ignores the auto_action setting and
halts at the SRM console. See Section 1.13 for information on halt
assertion.
2.19.2
bootdef_dev
The bootdef_dev environment variable specifies one or more
devices for booting the operating system. When more than one
device is listed, the system searches in the order listed and boots
from the first device with operating system software.
Syntax:
set bootdef_dev boot_device
Where boot_device is the name of the device on which the system software has
been loaded. To specify more than one device, separate the names with commas.
Enter the command show bootdef_dev to display the current default boot
device. Enter the command show device for a list of all devices in the system.
2-40 DS10 Console Reference
2.19.3
boot_osflags
The boot_osflags environment variable passes information to the
boot command. That information is dependent on the operating
system to be booted.
Syntax for Tru64 UNIX:
set boot_osflags flags_value
where flags_value can be:
a
Load operating system software from the specified boot device
(autoboot). Boot to multi-user mode.
i
Prompt for the name of a file to load and other options (boot
interactively). Boot to single-user mode.
s
Stop in single-user mode. Boots /vmunix to single-user mode and
stops at the # (root) prompt.
D
Full dump; implies “s” as well. By default, if Tru64 UNIX crashes, it
completes a partial memory dump. Specifying “D” forces a full
dump if the system crashes.
Syntax for OpenVMS: set boot_osflags root_number, boot_flags
Where root_number is the directory number of the system disk on which
OpenVMS files are located. For example:
root_number
Root Directory
0 (default)
[SYS0.SYSEXE]
1
[SYS1.SYSEXE]
2
[SYS2.SYSEXE]
3
[SYS3.SYSEXE]
And boot_flags are the hexadecimal value of the bit number or numbers set. To
specify multiple boot flags, add the flag values (logical OR). See Table 2–7.
SRM Console
2-41
Table 2–7 Settings for boot_osflags Bootflags (OpenVMS)
Flags_Value
Bit Number
Meaning
1
0
Bootstrap conversationally (enables you to
modify SYSGEN parameters in SYSBOOT).
2
1
Map XDELTA to running system.
4
2
Stop at initial system breakpoint.
8
3
Perform diagnostic bootstrap.
10
4
Stop at the bootstrap breakpoints.
20
5
Omit header from secondary bootstrap
image.
80
7
Prompt for the name of the secondary
bootstrap file.
100
8
Halt before secondary bootstrap.
10000
16
Display debug messages during booting.
20000
17
Display user messages during booting.
2-42 DS10 Console Reference
2.19.4
com1_baud
The default baud rate for the system is 9600. With the com1_baud
environment variable, you can set the baud rate to match that of
the device connected to the port.
Syntax:
set com1_baud baud_value
where baud_value is the new baud rate. A list of possible values is displayed by
attempting to set this environment variable to an unacceptable value (for
example, set com2_baud xxx).
NOTE: Disable the RMC to select a baud rate other than 9600. See Chapter 4.
You will be asked to confirm the change, as shown in Example 2–26.
Example 2–26 Changing Baud Rate
>>> set com1_baud 19200
Embedded Remote Console only supports 9600 baud. Continue? (Y/[N]) n
bad value - com1_baud not modified
>>>
2.19.5
com1_mode
The set com1_mode command sets the bypass modes of the
remote management console (see Chapter 4)
For modem connections, you can set the com1_mode variable to allow data to
partially or completely bypass the RMC. The bypass modes are snoop mode, soft
bypass mode, and firm bypass mode.
•
In snoop mode, you can type an escape sequence to enter RMC mode. RMC
mode provides a command-line interface for issuing commands to monitor
and control the system.
•
In soft bypass mode, you cannot enter RMC mode. But if an alert condition
or loss of carrier occurs, the RMC switches into snoop mode. From snoop
mode you can enter RMC mode.
SRM Console
2-43
•
In firm bypass mode, you cannot enter RMC mode. To enter RMC mode
from firm bypass mode, reset the com1_mode variable from the SRM
console.
set com1_mode value
Syntax:
where value can be:
snoop
Data partially bypasses RMC, but RMC taps into the data lines
and listens passively for the RMC escape sequence.
soft_bypass
Data bypasses RMC, but RMC switches automatically into snoop
mode if an alert condition or loss of carrier occurs.
firm_bypass
Data bypasses RMC. RMC is effectively disabled.
Example:
>>> set com1_mode
COM1_MODE (SNOOP, SOFT_BYPASS, FIRM_BYPASS)
2.19.6
console
The console terminal can be either a graphics monitor or a
serial terminal. The console environment variable specifies
which is used. Whenever you change the value of console, you
must reset the system by pressing the Halt/Reset button or
issuing the initialize command.
Syntax:
set console output_device
where output_device can be:
graphics
(default)
serial
The console terminal is a graphics monitor or a device connected
to the VGA or TGA module.
The console terminal is the device connected to the COM1 port.
2-44 DS10 Console Reference
2.19.7
ew*0_mode
Sets an Ethernet controller to run an AUI, ThinWire, or twistedpair Ethernet network. The default is auto-sense. For the fast
setting, the device defaults to fast.
set ew*0_mode value
Syntax:
where value can be:
aui
auto-sense
Device type is AUI.
Device type is sensed by the console.
twisted-pair
Device type is 10BaseT (twisted pair).
fast duplex,
twisted-pair
Device type is duplex 10BaseT.
fast
fast FD
BNC
auto-negotiate
2.19.8
Device type is fast SCSI.
Device type is fast full duplex SCSI.
Device type is BNC.
DE500-BA
ew*0_protocols
Enables network protocols for booting and other functions.
Syntax:
set ew*0_protocols protocol_value
where protocol_value can be:
mop (default)
bootp
bootp,mop
Sets the network protocol to mop (Maintenance Operations
Protocol), the setting typically used with the OpenVMS
operating system.
Sets the network protocol to bootp, the setting typically
used with the Tru64 UNIX operating system.
When both are listed, the system attempts to use the mop
protocol first, regardless of which is listed first. If not
successful, it then attempts the bootp protocol.
SRM Console
2-45
2.19.9
kbd_hardware_type
Used only on systems with the language variant 3C (Français),
this environment variable sets the keyboard hardware type as
either PCXAL or LK411 and enables the system to interpret the
terminal keyboard layout correctly.
set kbd_hardware_type keyboard_type
Syntax:
where keyboard_type can be:
pcxal
(default)
lk411
Selects the default keyboard hardware type.
Selects the LK411 keyboard layout for use with language
variant 3C (Français).
Whenever you change the value of kbd_hardware_type, you must reset the
system by pressing the Halt/Reset button or issuing the initialize command.
2.19.10 language
Specifies the keyboard layout, which is language dependent.
The setting of the language environment variable must match the
language of the keyboard variant. Whenever you change the
value of language, you must reset the system by pressing the
Halt/Reset button or issuing the initialize command.
Syntax:
set language language_code
where language_code can be:
0
30
32
34
36
38
3A
3C
3E
No language (cryptic)
Dansk (Danish)
Deutsch (German)
Deutsch (Schweiz) (Swiss)
English (American)
English (British/Irish)
Español (Spanish)
Français (French)
Français (Canadian)
2-46 DS10 Console Reference
40
42
44
46
48
4A
4C
4E
Français (Suisse Romande)
Italiano (Italian)
Nederlands (Netherlands)
Norsk (Norwegian)
Portuguese (Portuguese)
Suomi (Finnish)
Svenska (Swedish)
Belgisch-Nederlands (Dutch)
2.19.11 os_type
The os_type environment variable specifies the default operating
system. This variable is set at the factory to the setting for the
operating system purchased. Use this command to change the
factory default setting. Whenever you change the value of
os_type, you must reset the system by pressing the Halt/Reset
button or issuing the initialize command.
set os_type os_type
Syntax:
where os_type can be:
unix
Tru64 UNIX is the default operating system, and the SRM
firmware is started during power-up or reset.
openvms
OpenVMS is the default operating system, and the SRM firmware
is started during power-up or reset.
nt
Windows NT is the default operating system. The SRM firmware
is started, and it loads and starts the AlphaBIOS firmware during
power-up or reset. (If a halt assertion condition exists, this
environment variable is overridden, and the SRM firmware does
not load and start the AlphaBIOS console.)
2.19.12 password
Sets or clears the console password stored in NVRAM.
Syntax:
set password
where the password is not an argument to the set password command; the
console prompts the user for the string, which must be between 15 and 30
characters.
SRM Console
2-47
2.19.13 pci_parity
Disables or enables parity checking on the PCI bus.
set pci_parity value
Syntax:
where value can be:
(default) on
Enables PCI parity checking.
off
Disables PCI parity checking.
Some PCI devices do not implement PCI parity checking, and some have a
parity-generating scheme in which the parity is sometimes incorrect or is not
fully compliant with the PCI specification. A side effect of this is that
superfluous PCI parity errors are reported by the host PCI bridge. In such
cases, the device can be used as long as parity is not checked; disabling PCI
parity checking prevents false parity errors that can cause system problems.
2.19.14 pk*0_fast
Enables fast SCSI to perform in either standard or fast mode.
set pk*0_fast scsi_speed
Syntax:
where scsi_speed can be:
(default) 1
0
The controller is in fast SCSI mode.
The controller is in standard SCSI mode.
If the system has at least one fast SCSI device, set the default controller speed
to fast SCSI (1). Devices on a controller that connects to both standard and fast
SCSI devices will perform at the appropriate rate for the device. If the system
has no fast SCSI devices, set the default controller speed to standard SCSI (0).
If a fast SCSI device is on a controller set to standard, it will perform in
standard mode.
2-48 DS10 Console Reference
2.19.15 pk*0_host_id
Sets the controller host bus node ID to a value between 0 and 7.
set pk*_host_id scsi_node_id
Syntax:
where scsi_node_id is the bus node ID, a number from 0 to 7.
Each SCSI bus in the system requires a controller. Buses can theoretically
support up to eight devices; however, the eighth device must always be a
controller. Each device on the bus, including the controller, must have a unique
ID, which is a number between 0 and 7. This is the bus node ID number.
On each bus, the default bus node ID for the controller is set to 7. You do not
need to change the controller bus node ID unless you place two or more
controllers on the same bus.
To list the controllers on your system, enter the command show device. SCSI
devices begin with the letters “pk” (for example, pka0). The third letter is the
adapter ID for the controller. When entering the command set pk*0_host_id,
replace the asterisk with the adapter ID letter.
2.19.16 pk*0_soft_term
Enables or disables SCSI terminators. This command applies to
systems that use the QLogic ISP1040 SCSI controller. The
QLogic ISP1040 SCSI controller implements the 16-bit wide SCSI
bus. The QLogic module has two terminators, one for the low
eight bits and one for the high eight bits.
set pk*0_soft_term value
Syntax:
where value can be:
Off
Disables termination of all 16 bits.
(default) low
Enables low eight bits and disables high eight bits.
High
Enables high eight bits and disables low eight bits.
On
Enables all 16 bits.
Diff
Places the bus in differential mode.
SRM Console
2-49
2.19.17 tt_allow_login
Enables or disables login to the SRM console firmware on
alternate console ports. If the environment variable console is set
to serial, the primary console device is the terminal connected
through the COM1 port. The command set tt_allow_login 1 enables
logins through either the COM2 port or a graphics monitor.
set tt_allow_login value
Syntax:
where value can be:
(default) 1
Enables login through the COM2 port or a graphics monitor.
0
Disables login through the COM2 port or a graphics monitor.
2-50 DS10 Console Reference
Chapter 3
AlphaBIOS Console
AlphaBIOS is the graphical interface that supports the Microsoft Windows NT
operating system and some utility programs. This chapter explains how to
perform common system management tasks with AlphaBIOS.
Sections in this chapter are:
•
Starting AlphaBIOS
•
Keyboard Conventions and Help
•
System Configuration
•
Updating Firmware
•
Setting Up the Hard Disk
•
Performing Setup Tasks
•
Installing Operating System
•
Selecting the Version of Windows NT
•
Designating a Primary Operating System
•
Switching from AlphaBIOS to SRM Console
•
Running Utility Programs
NOTE: To run firmware tests on a Windows NT system, switch to the SRM
console and issue the test command. See Section 2.7.
AlphaBIOS Console
3-1
3.1
Starting AlphaBIOS
Start AlphaBIOS Setup by pressing F2 from the Boot screen
displayed at power-up or reset.
Figure 3–1 Boot Screen
PK1450 - 98
3-2 DS10 Console Reference
The boot screen shown in Figure 3–1 is displayed at power-up and reset. Press
F2 at this screen to enter the setup program.
The AlphaBIOS Setup screen (Figure 3–2) is displayed. From this screen you
can select the tasks to perform. Use the arrow keys to select the menu item you
want and press Enter. (Refer to Section 3.2 for information on navigating the
AlphaBIOS screens.)
Figure 3–2 AlphaBIOS Setup Screen
AlphaBIOS Setup
F1= Help
Display System
AlphaBIOS Upgrade…
Hard Disk Setup…
CMOS Setup…
Network Setup…
Install NT
Operating System
Utilities
About AlphaBIOS…
Press ENTER to partition or format hard disks.
ESC = Exit
AlphaBIOS Console
3-3
3.2
Keyboard Conventions and Help
AlphaBIOS uses widely accepted keys and key combinations for
navigating the interface and selecting items.
Figure 3–3 Typical First-Level Help Screen
Help: CMOS Setup
F1=Key Help
F3
Change color scheme.
F6
Enter Advanced CMOS Setup.
F7
Set factory default CMOS settings.
ESC
Exit CMOS Setup and discard any changes.
F10
Exit CMOS Setup and save changes,
including changes from Advanced CMOS Setup.
ENTER=Continue
PK-0724
AlphaBIOS uses DOS and Windows keyboard conventions for navigating the
interface and selecting items. The valid keystrokes are listed in the keyboard
help screens.
Two levels of keyboard help are available. The first level is reached by pressing
F1 once, and shows explanations of the keystrokes available for the specific part
of AlphaBIOS currently displayed. An example of the help displayed by pressing
F1 once, in this case from the CMOS Setup screen, is shown in Figure 3–3.
The second level of keyboard help, reached by pressing F1 from the first help
screen, shows explanations of the keystrokes available for navigating the
interface throughout AlphaBIOS (see Figure 3–4).
3-4 DS10 Console Reference
Figure 3–4 Second-Level Help Screen
AlphaBIOS Setup
F1=Help
Help: Action Keys
TAB
Move highlight forward between fields of a dialog.
SHIFT+TAB
Move highlight backward between fields of a dialog.
Move highlight within a menu, or cycle through available field
values in a dialog window.
ALT+
Drop down a menu of choices from a drop-down listbox.
drop-down listbox can be recognized by the
symbol.
HOME
Move to the beginning of a text entry field.
END
Move to the end of a test entry field.
A
Move to the left or right in a text entry field.
ESC
Discard changes and/or backup to previous screen.
ENTER=Continue
PK-0725
AlphaBIOS Console
3-5
3.3
System Configuration
3.3.1
Displaying the System Configuration
The Display System Configuration screen gives information
about the system’s installed processor, memory, attached
devices, and option boards. From the AlphaBIOS Setup screen
select Display System Configuration, then the category for the
information you need.
Figure 3–5 Display System Configuration Screen
Display System Configuration
Systemboard Configuration
Hard Disk Configuration
PCI Configuration
SCSI Configuration
ISA Configuration
Memory Configuration
Integrated Peripherals
System Type:
AlphaServer DS10
Processor: Alpha 21264-4, Revision V1.8.208 (1 Processor)
Speed:
466 MHz
Cache:
2 MB
Memory:
512 MB
Floppy Drive A:
Floppy Drive B:
Keyboard:
3.5” 1.44 MB
None
U.S. 101-key keyboard
AlphaBIOS Version: 6.40-1
ESC = Exit
3-6 DS10 Console Reference
990121.1130
F1= Help
Display the system configuration as follows:
1. Start AlphaBIOS, select Display System Configuration, and press Enter.
2. In the Display System Configuration screen, use the arrow keys to select
the configuration category you want to see.
From this screen, you can view configuration information about:
•
System board
•
Hard disk
•
PCI bus
•
SCSI configuration
•
ISA configuration (detected ISA devices)
•
Memory
•
Integrated peripherals
The sections that follow explain the display for each component.
AlphaBIOS Console
3-7
3.3.2
System Board Configuration
Figure 3–6 System Board Configuration
Display System Configuration
Systemboard Configuration
Hard Disk Configuration
PCI Configuration
SCSI Configuration
ISA Configuration
Memory Configuration
Integrated Peripherals
➊
System Type:
➋ Processor:
➌
Speed:
➍
Cache:
➎ Memory:
AlphaServer DS10
Alpha 21264-4, Revision V1.8.208 (1 Processor)
466 MHz
2 MB
512 MB
Floppy Drive A:
Floppy Drive B:
Keyboard:
3.5” 1.44 MB
None
U.S. 101-key keyboard
➏ AlphaBIOS Version: 6.40-1
ESC = Exit
3-8 DS10 Console Reference
990121.1130
F1= Help
➊ System type — The model number of the system.
➋ Processor — The model and revision of the processor chip. Revisionlevel information can be useful in troubleshooting problems with
technical support personnel.
➌ Speed — The speed of the processor.
➍ Cache — The amount of static RAM cache memory installed.
➎ Memory — The amount of main memory in the system.
➏ Firmware version — The version of AlphaBIOS currently running on
the system.
AlphaBIOS Console
3-9
3.3.3
Hard Disk Configuration
Figure 3–7 Hard Disk Configuration
Display System Configuration
F1= Help
Systemboard Configuration
Hard Disk Configuration
PCI Configuration
SCSI Configuration
ISA Configuration
Memory Configuration
Integrated Peripherals
➊
➋
Disk 0
ATAPI #0, SCSI ID 0
8063 MB
QUANTUM FIREBALL SE8 API.
Partition 1
4095 MB
FAT
➐
Partition 2
➏
6 MB ➑ FAT
Partition 3
3962 MB
FAT
➌
➍
➎
ENTER =Select ESC = Exit
NOTE: This screen is for information only; it cannot be edited. To make
changes to the hard disk setup, use the Hard Disk Setup screen.
3-10 DS10 Console Reference
➊ Physical Disk ID – Based on the SCSI ID. The disk with the lowest
SCSI ID is disk 0, the disk with the next lowest SCSI ID is disk 1.
➋ Controller – The brand and model of the SCSI chip used on the SCSI
controller.
➌ Controller number – Based on how many SCSI controllers of a
particular type are installed in the system. The first controller of a
type is always numbered 0.
➍ SCSI ID number – A unique number you assign to each SCSI device
installed in the system. This is usually done with jumpers or a thumb
wheel attached to the drive housing.
➎ Size – The raw capacity of the drive. Formatting the drive with
different file systems, FAT or NTFS, may result in different usable
capacity because of the differences in storage management under those
file systems.
➏ Partition number – Within a single drive, partition numbers are
assigned in sequential order: 1, 2, 3, and so on. The partitions
populate the drive from the innermost cylinders to the outermost
cylinders. If you have a large hard disk (over 800 MB) and plan to use
the FAT file system, break the disk into several smaller partitions
because the FAT file system uses disk space more efficiently at smaller
partition sizes. This is not a concern for the NTFS file system,
however, since it uses disk space very efficiently at all partition sizes.
➐ Partition size – The raw (unformatted) storage capacity of the
partition. Actual storage space will differ based on the file system with
which the partition is formatted.
➑ Partition format – The file system (if any) used on a partition. This
field displays FAT, NTFS, or unrecognized (if the partition is
unformatted).
AlphaBIOS Console
3-11
3.3.4
PCI Configuration
Figure 3–8 PCI Configuration
Display System Configuration
F1= Help
Systemboard Configuration
Hard Disk Configuration
PCI Configuration
SCSI Configuration
ISA Configuration
Memory Configuration
Integrated Peripherals
➊
➋
➌
➍
Device Name
AcerLabs USB 5237
AcerLabs PCI-ISA
DIGITAL
DIGITAL
AcerLabs IDE
Matrox Millenium
Device Type
USB
ISA bridge
Ethernet
Ethernet
IDE
VGA
Revision
3
195
65
65
193
0
Physical Slot
Embedded
Embedded
Embedded
Embedded
Embedded
Slot 3
ENTER = Select ESC =Exit
3-12 DS10 Console Reference
➊ Device name — The name and model of the device as recorded in the
device’s firmware.
➋ Device type — Lists the function of the device in the system.
➌ Revision — The revision level of the device signifies the number of
times it has been updated by the manufacturer.
➍ Physical slot — Lists the actual PCI slot number to which the device is
attached.
Figure 3–9 PCI Slots
PCI Slot 4
64 Bit
PCI Slot 3
64 Bit
PCI Slot 2
PCI Slot 1
64 Bit
32 Bit
PK1045-99
You can find additional detail about any of the PCI devices listed in the
Advanced PCI Information screen. Follow this procedure to view this screen:
1. Press Enter to enable selection in the device list.
2. Use the arrow keys to select the device for which you want additional detail.
3. Press Enter, and the detail is displayed.
4. Press Escape to return to the table of PCI devices.
The Advanced PCI Information screen is shown in Figure 3–10.
AlphaBIOS Console
3-13
Figure 3–10 Advanced PCI Information
Display System Configuration
Advanced PCI Information
➊
➋
F1=Help
➌
Bus Number=0, Device Number=1, Function Number=0
➍
Configuration Space:
Register
Hex offset
Vendor ID
Device ID
Command
Status
Revision ID
Prog. I/F
Sub Class Code
Class Code
Cache Line Size
Latency Timer
Header Type
BIST
Base Address 0
ENTER
00
02
04
06
08
09
0a
0b
0c
0d
0e
0f
10
Hex
1090
5237
0280
0280
03
10
03
0c
08
20
00
00
03884000
â
=Continue
➊ Bus number — The virtual PCI bus number.
➋ Device number — The PCI bus device number.
➌ Function number — Represents the number assigned to a particular
function on a multifunction device. For example, a combination
Ethernet/SCSI controller would be listed twice, with the first function
listed as 0 and the other as 1.
➍ Configuration header space — Displays the information in the selected
device’s PCI configuration space.
Press ESC to return to the list of PCI devices.
3-14 DS10 Console Reference
3.3.5
SCSI Configuration
Figure 3–11 SCSI Configuration
Display System Configuration
Systemboard Configuration
Hard Disk Configuration
PCI Configuration
SCSI Configuration
ISA Configuration
Memory Configuration
Integrated Peripherals
F1= Help
ATAPI #0
ATAPI #1
➊
ATAPI #0, SCSI ID 255, SCSI Bus 0
➋
➌
➍
SCSI
Device
Size
Description
➎
0
Disk 0
8063
Quantum Fireball SE8 API
ENTER = Select ESC =Exit
AlphaBIOS Console
3-15
➊ SCSI controller information — Describes the physical characteristics of
the selected SCSI controller. This line includes:
Controller — Brand and model of SCSI chip used on the SCSI
controller.
Controller number — Based on the number of SCSI controllers of a
particular type in the system. The first controller of a type is always
numbered 0.
SCSI ID number — A unique number assigned to the SCSI controller.
The standard scheme in numbering controllers is for controllers to be
SCSI ID 7.
SCSI bus number — Indicates if the controller is first or second in the
system. The first controller is tied to SCSI bus 0, and the second to
SCSI bus 1.
➋ SCSI ID — A unique number you assign to each SCSI device controlled
by the controller. This is usually done with jumpers or a thumb wheel
attached to the drive housing.
➌ Device type —Hard disk, CD-ROM, scanner, or other type of device.
➍ Size — The raw capacity of the drive. Formatting the drive with
different file systems (for example, FAT and NTFS) may result in
different usable sizes because of differences in the way those file
systems manage storage. This field is left blank if it is not applicable to
a device (for example, a scanner).
➎ Description — The name and model of the device as recorded in the
device’s firmware.
3-16 DS10 Console Reference
3.3.6
Memory Configuration
Figure 3–12 Memory Configuration
Display System Configuration
F1= Help
Systemboard Configuration
Hard Disk Configuration
PCI Configuration
SCSI Configuration
ISA Configuration
Memory Configuration
Integrated Peripherals
System Memory Configuration
Bank 0: 64 MB (32 MB per DIMM)
-- Starting Address = 0x00000000
Bank 1: 64 MB (32 MB per DIMM)
-- Starting Address = 0x40000000
ESC =Exit
AlphaBIOS Console
3-17
3.3.7
Integrated Peripherals
Figure 3–13 Integrated Peripherals
Display System Configuration
F1=Help
Systemboard Configuration
Hard Disk Configuration
PCI Configuration
SCSI Configuration
ISA Configuration
Memory Configuration
Integrated Peripherals
Integrated Peripheral State
➊
➋
➌
➍
Serial 0:
Enabled [ port 0x3f8, IRQ 4 ]
Serial 1:
Enabled [ port 0x2f8, IRQ 3]
Parallel:
Enabled [ port 0x3bc, IRQ 7]
Floppy Ctrl: Enabled [ port 0x3f0, IRQ 6, DMA2]
Kbd/Mouse: Enabled [ port 0x60, kbd IRQ 1, mouse IRQ 12]
Acer IDE Chnl 0: Enabled [ port 0x1f0, IRQ 14]
ESC
=Exit
➊ Device type — The physical device as it exists on the system board.
➋ MS-DOS name — Shows if the device is enabled, and if it is enabled,
the addressable MS-DOS name for the device.
➌ Port address — The physical memory location for data received into
the device, and sent from the device, respectively.
➍ Interrupt — The interrupt request line (IRQ) used by the device to get
the CPU’s attention.
3-18 DS10 Console Reference
3.4
Updating Firmware
Insert the CD-ROM or diskette with the updated firmware and
select Upgrade AlphaBIOS from the main AlphaBIOS Setup
screen. Use the Loadable Firmware Update Utility (LFU) to
perform the update. The LFU exit command causes a system
reset.
Figure 3–14 Updating Firmware
AlphaBIOS Setup
F1=Help
Display System
AlphaBIOS upgrade…
Hard Disk Setup…
CMOS Setup…
Network Setup…
Install Windows NT…
Utilities
About AlphaBIOS…
Press ENTER to install new firmware image(s) from floppy, CD-ROM, or
Network.
ESC
=Exit
AlphaBIOS Console
3-19
As new versions of Windows NT are released, it might be necessary to upgrade
AlphaBIOS to the latest version. Also, as improvements are made to
AlphaBIOS, you may wish to upgrade to take advantage of new features.
Use this procedure to upgrade from an earlier version of AlphaBIOS:
1. Insert the diskette or CD-ROM containing the AlphaBIOS upgrade.
2. If you are not already running AlphaBIOS Setup, restart your system and
press F2 when the Boot screen is displayed.
3. In the main AlphaBIOS Setup screen, select AlphaBIOS Upgrade and
press Enter.
The system is reset and the Loadable Firmware Update (LFU) utility is
started.
4. When the upgrade is complete, issue the LFU exit command. The system is
reset and you are returned to AlphaBIOS.
3-20 DS10 Console Reference
3.5
Setting Up the Hard Disk
Either execute an express or a custom hard disk setup. An
express setup, described here, creates the recommended
partitions on the first hard disk, but it does not map bad sectors.
Custom hard disk setup is described in Sections 3.5.1 and 3.5.2.
Figure 3–15 Hard Disk Setup Screen
Hard Disk Setup
➊
➋
➌
➍
Disk 0
AIC78XX #0, SCSI ID 0
DEC
RZ1CB-CS (C)
Partition 1
Partition 2
➏
Disk 1
AIC78XX #0, SCSI ID 1
DEC
RZ1CB-CS (C)
Partition 1
F1= Help
➎
4091 MB
➐
4085 MB
FAT
6 MB ➑ FAT
4091 MB
4091 MB
NTFS
➒
INSERT =New DEL = Delete
F6 =Format
F7 =Express ESC
=Exit
CAUTION: Hard disk changes are immediate; unintended data loss could
occur, use care when changing your hard disk arrangement.
➊ Physical disk ID — Based on the SCSI ID. The disk with the lowest
SCSI ID is disk 0, the disk with the next lowest SCSI ID is disk 1, and
so on.
➋ Controller — Brand and model of SCSI chip used on the SCSI
controller.
➌ Controller number — Based on how many SCSI controllers of a
particular type are installed in the system. The first controller of a type
is always numbered 0.
AlphaBIOS Console
3-21
➍ SCSI ID number — A unique number you assign each SCSI device in
the system. This is usually done by jumpers or a thumb wheel attached
to the drive.
➎ Size — The raw capacity of the drive. Formatting the drive with
different file systems (for example, FAT and NTFS) may result in
different usable sizes because of the differences in how storage is
managed under those file systems.
➏ Partition number — Within a single drive, partition numbers are
assigned in sequential order: 1, 2, 3, and so on. The partitions populate
the drive from the innermost cylinders to the outermost. If you have a
large hard disk (over 800 MB) and plan to use the FAT file system, it is
a good idea to break the disk into several smaller partitions because
the FAT file system uses disk space more efficiently at smaller
partition sizes. This is not necessary for the NTFS file system, since it
uses disk space very efficiently at all partition sizes.
➐ Partition size — The raw (unformatted) storage capacity of the
partition. Actual storage space will differ based on the file system with
which the partition is formatted.
➑ Partition format — The file system (if any) used on a partition. This
field displays FAT, NTFS, or unrecognized (if the partition is
unformatted).
➒ Disk setup options
Insert partition (Insert key) — Use this option to create new partitions.
Before creating a new partition, be sure to select an unpartitioned
space. Pressing the Insert key while an already partitioned space is
selected causes an informational error to be displayed.
Delete partition (Delete key) — Use this option to delete existing
partitions. Before deleting a partition, be sure to back up any data you
want to save on the partition. Deleting a partition deletes all data on
that partition but leaves the rest of the disk unaffected. Pressing the
Delete key while an unpartitioned space is selected displays an
informational error.
Format partition (F6 key) — Format a partitioned space with the FAT
file system.
Express setup (F7 key) — Create the default recommended partition
arrangement for Windows NT.
3-22 DS10 Console Reference
Exit (Escape key) — Return to the AlphaBIOS Setup screen.
An express hard disk setup creates the recommended partition arrangement on
the first hard disk (disk 0). It does not, however, format the large partition with
NTFS, and it does not map bad sectors on the disk. The NTFS formatting can be
done once Windows NT has been installed.
To perform an express hard disk setup
1. If you have any needed information on your disk, back it up before
proceeding.
2. Start AlphaBIOS Setup, select Hard Disk Setup, and press Enter.
3. Press F7 to enter Express Setup.
4. Press F10 to continue with the setup.
AlphaBIOS Console
3-23
3.5.1
Creating and Deleting Partitions Manually
Use the Create Partition and Delete Partition options if you
need to create a custom hard disk partition arrangement or
otherwise manually manage your hard disk partitions.
Figure 3–16 Create New Partition Dialog Box
Hard Disk Setup
Disk 0
QLISP1040 #0, SCSI ID 3
510 MB
Partition 1
200 MB
Unused
310 MB
Create new partition, Disk 0 Partition 2
NTFS
Disk 1
NTFS
FAT
Available space:
310 MB
New Partition Size:
200
ENTER
= Continue
ESC
MB
= Cancel
To create a partition
1. Start AlphaBIOS and select Hard Disk Setup. Press Enter.
2. Select the disk on which to create the partition.
3. If one or more partitions already exist on the disk, select the unpartitioned
space.
4. Press Insert. A dialog box is displayed, similar to Figure 3–16.
5. Type the size of the partition to create and press Enter.
3-24 DS10 Console Reference
To delete a partition
1. Start AlphaBIOS and select Hard Disk Setup. Press Enter.
2. Select the partition to be deleted (see ➊ in Figure 3–17).
3. Press Delete. A dialog box is displayed (see ➋).
4. Press F10 to confirm the deletion.
Figure 3–17 Delete Partition Dialog Box
Hard Disk Setup
Disk 0
➊
Disk 1
QLISP1040 #0, SCSI ID 3
Partition 1
Partition 2
Unused
510 MB
200 MB
200 MB
100 MB
NCRC810 #0, SCSI ID 5
Partition 1
Parti
1001
995
MB
MB
NTFS
FAT
NTFS
FAT
Delete Disk 0, Partition 2
The delete operation will destroy all
data on partition 2 of Disk 0. ➋
Press F10 to continue. Press ESC to
Cancel.
F10
=Continue
ES C
=Cancel
AlphaBIOS Console
3-25
3.5.2
Formatting a FAT Partition
AlphaBIOS can format partitions with the FAT file system. Use
Windows NT to format a partition using NTFS.
Figure 3–18 Formatting a FAT Partition
Hard Disk Setup
Disk 0
➊
Disk 1
QLISP1040 #0, SCSI ID 3
Partition 1
Partition 2
Unused
NCRC810 #0, SCSI ID 5
Partition 1
Parti
➋
510
200
200
100
MB
MB
MB
MB
1001
995
MB
MB
Choose Format Method:
Format Method
Standard
Format
Standard Format
Quick Format
F10
=Continue
3-26 DS10 Console Reference
ES C
=Cancel
NTFS
Unrecognized
NTFS
FAT
To format a FAT partition
1. Start AlphaBIOS and select Hard Disk Setup. Press Enter.
2. Select the partition to be formatted (see ➊ in Figure 3–18).
3. Press F6. A dialog box is displayed, asking whether to perform a quick or
standard format (see ➋). If you select Quick Format, the formatting is
completed immediately, but no bad sectors are mapped. If you select
Standard Format, a dialog box similar to that in Figure 3–19 is displayed
while the drive is formatted, showing the progress of the formatting.
Standard formatting maps bad sectors.
4. Select a format method and press Enter.
Figure 3–19 Standard Formatting
Hard Disk Setup
Disk
0
Disk
1
QLISP1040 #0,
510
MB
Partition 1
Partition 2
Unused
NCRC810
#0,
Partition
Partition
SCSI
SCSI
ID
ID
5
1
2
3
200
200
100
MB
MB
MB
1001
MB
995 MB
6 MB
NTFS
Unrecognized
NTFS
FAT
Formatting…
25%
ESC
=Cancel
AlphaBIOS Console
3-27
3.6
Performing Setup Tasks
CMOS Setup is used to configure several system parameters.
CMOS Setup has two modes: Standard CMOS Setup is used to
configure basic system parameters; Advanced CMOS Setup is
used for system-specific parameters and password protection.
Figure 3–20 Standard CMOS Setup Screen
CMOS Setup
1 Date: Friday,
Time:
April
1999
23
F1=Help
1999
13:22:27
2 Floppy Drive A: 3.5" 1.44 MB
Floppy Drive B: None
U.S. 101-key keyboard
3 Keyboard:
4
Auto Start: Enabled
Auto Start Count: 30 Seconds
Press
or
to modify date fields.
take effect immediately.
Date modifications will
5
F3=Color
F6=Advanced
F7=Defaults
ESC=Discard Changes
F10=Save Changes
PK-0749d
To enter Standard CMOS Setup
Start AlphaBIOS, select CMOS Setup, and press Enter.
3-28 DS10 Console Reference
➊ Date and time — When setting the time, use the 24-hour format. (For
example, 10:00 p.m. is 22:00:00.)
➋ Floppy drive — The only drive type supported is 3.5 inch, 1.44 MB.
➌ Keyboard — The keyboard setting makes it possible to use most
language keyboards. To ensure correct character mappings, the
language of your keyboard, Windows NT, and the keyboard language
selection in CMOS Setup should all match.
➍ Auto start and auto start count — The Auto Start setting determines
whether the primary operating system is automatically started after
the system is reset or power-cycled. The Auto Start Count setting is the
amount of time the Boot screen is displayed before the default system
is automatically started. This delay gives you the opportunity, after
resetting or power-cycling the system, to select another version of
Windows NT to start or to enter AlphaBIOS Setup.
➎ Standard CMOS Setup options
Color (F3 key) — Repeatedly cycles through the available AlphaBIOS
color schemes.
Advanced (F6 key) — Displays the Advanced CMOS Setup screen.
Defaults (F7 key) — Restores the default Standard CMOS Setup
values without affecting the Advanced CMOS Setup values.
Discard changes (Escape key) — Restores the settings in effect when
you started CMOS Setup. This option also discards changes made in
Advanced CMOS Setup.
Save changes (F10 key) — Saves changes made in both the standard
and advanced modes of CMOS Setup.
Continued on next page
AlphaBIOS Console
3-29
Figure 3–21 Advanced CMOS Setup Screen
CMOS Setup
F1
Advanced CMOS Setup
➊
➋
➌
➍
PCI Parity Checking:
Power-up Memory Test:
AlphaBIOS Password Option:
Console Selection:
Disabled
Full
Disabled
Windows NT Console
(AlphaBIOS)
➎
Warm Reboot:
Enabled
F1
¹
Press º or ¹ to to enable or disable detection of PCI bus parity error.
Some non-compliant PCI option boards do not work properly with PCI parity
checking enabled.
➏
ESC
= Discard Changes
F10
= Save Changes
To Enter Advanced CMOS Setup
1. Start AlphaBIOS, select CMOS Setup, and press Enter.
2. In the Standard CMOS Setup screen, press F6.
3-30 DS10 Console Reference
➊ PCI parity checking — Enables and disables settings for PCI parity
checking, which ensures data integrity across the PCI bus. Because
some third-party PCI options do not correctly implement PCI parity
generation, the default is Disabled.
➋ Power-up memory test — Enables and disables settings for the powerup memory test.
➌ Password setup — Enables and disables settings for password setup.
Password protection provides two levels of security for your system:
setup, which requires a password to start AlphaBIOS Setup, and
startup, which requires a password before the system initializes.
Startup protection provides more comprehensive protection than setup
protection because the system cannot be used at all until the correct
password is entered.
➍ Console selection — Switches from AlphaBIOS to SRM firmware. If
you select OpenVMS (SRM) or Tru64 UNIX (SRM), the next time you
reset your system, the SRM firmware will be loaded instead of
AlphaBIOS. This menu selection changes the setting of the os_type
environment variable in the SRM console.
➎ Warm Reboot — Enable (the default) results in the system restarting
normally on a shutdown and restart from the operating system.
Disable results in the necessity to restart the machine by pressing
reset or power-cycling.
➏ Advanced CMOS Setup options
Discard changes (Escape key) —Restores those settings in effect when
you started Advanced CMOS Setup. This does not discard changes
made to Standard CMOS Setup.
Save Changes (F10 key) — Saves changes made in Advanced CMOS
Setup. When exiting CMOS Setup, you must also save your changes
at the Standard CMOS Setup screen for the changes to be stored
permanently.
AlphaBIOS Console
3-31
3.7
Installing Operating System
Install your operating system from the CD-ROM. Up to three
versions of the operating system can be resident in the system at
one time. Read the instructions carefully; it is easy to install
the wrong CD-ROM driver.
Figure 3–22 Installing Windows NT
AlphaBIOS Setup
Display System Configuration…
AlphaBIOS Upgrade…
Hard Disk Setup…
CMOS Setup…
Network Setup…
Install Operating System
Utilities
About AlphaBIOS…
8
Press ENTER to install Windows NT.
ESC =Exit
3-32 DS10 Console Reference
F1= Help
If Windows NT was installed at the factory, Windows NT setup will start
automatically the first time the system powers up.
NOTE: Steps 1 and 2 in the following procedure are necessary only when you
are first setting up your system. On subsequent installations and
upgrades, begin at step 3.
1. Use CMOS Setup to set the system date and time: start AlphaBIOS
Setup, select CMOS Setup, and press Enter.
2. Perform an express hard disk setup: return to the main AlphaBIOS Setup
screen, select Hard Disk Setup, and press Enter.
3. Put the Windows NT CD into the CD-ROM drive.
4. Start AlphaBIOS Setup, select Install Windows NT, and press Enter.
Follow the prompts to complete the installation. For more information on
installing Windows NT, refer to the Installation Guide in your Windows NT
software package.
AlphaBIOS Console
3-33
3.8
Selecting the Version of Windows NT
Up to three versions of Windows NT can reside on the system at
one time. Select the version that will be started from the
Operating System Selection Setup screen.
Figure 3–23 Operating System Selections
Operating System Selection Setup
Windows NT Server 4.0
Windows NT Server 5.0
Boot Name:
Boot File:
OS Path:
OS Options:
INSERT = New
DEL = Delete
Primary Operating System
Windows NT Server
4.0
Disk 0, partition 2
\os\winnt40\osloader.exe
Disk 0,
\WINNT4
partition 1
F6
= Edit
F8
= Primary
F7
= Copy
F9
= Validate
ES
C
F10
= Discard Changes
= Save Changes
Operating System Selection Setup
Windows NT Server 5.0
Windows NT Server 4.0
Boot Name:
Boot File:
OS Path:
OS Options:
INSERT
DEL
= New
= Delete
Primary Operating System
Windows NT Server
5.0
Disk 0, partition 2
Disk 0, partition 1
\os\winnt50\osloader.exe
\WINNT5
F6
= Edit
F8
= Primary
F7
= Copy
F9
= Validate
3-34 DS10 Console Reference
ES
C
F10
= Discard Changes
= Save Changes
NOTE: The term “operating system selection,” as it is used in this context, refers
to a version of Windows NT. It does not pertain to the Tru64 UNIX and
OpenVMS operating systems.
Each operating system selection is a set of information for a version of Windows
NT. It describes the disk and partition containing the OSLOADER.EXE file
associated with a particular operating system installation, as well as the path to
the operating system itself. In addition, the operating system selection contains
any options passed to the operating system during boot.
By default, one operating system selection is displayed on the AlphaBIOS
Boot screen for each operating system installed on the system. It is not
normally necessary to modify operating system selections, since the Windows
NT installation creates and modifies operating system selections as needed. If
you add SCSI controllers after the installation of Windows NT, it may be
necessary to modify operating system selections. Depending on what kind of
SCSI controller is added, in which slot it is placed, and where its driver is in the
startup order relative to other existing controllers, the disk numbering may
change and modification of operating system selections may be required.
AlphaBIOS Console
3-35
3.9
Designating a Primary Operating System
3.9.1
Selecting a Primary Operating System
Figure 3–24 Primary Operating System
AlphaBIOS 5.29
Please select the operating system to start:
1
Windows NT Server 4.0
Windows NT Server 5.0
Use
and
to move the highlight to your choice.
Press Enter to choose.
CMOS Setup
Date:
Time:
Friday,
11:26:22
Nov
7
1997
Floppy Drive A: 3.5" 1.44 MB
Floppy Drive B: None
Keyboard: U.S. 101-key keyboard
Auto Start: Enabled
Auto Start Count: 30 Seconds
2
Operating System Selection Setup
Windows NT Server 4.0
Windows NT Server 5.0
Primary Operating System
3
PK-0720D-97
3-36 DS10 Console Reference
Three versions of Windows NT can reside on the system at the same time. This
is useful in a variety of circumstancesfor example, when testing application
compatibility across different versions of Windows NT.
Each time you install a separate version of Windows NT, a new operating
system selection is created. Although you can start any of the installed versions
of Windows NT, one of them must be the primary operating system. The version
of Windows NT that you select as the primary operating system is the one that
automatically starts if the Auto Start option is enabled in AlphaBIOS.
Figure 3–24 illustrates the relationship between multiple installations of the
operating-system, Auto Start, and the primary operating system.
➊
The primary operating system is listed first on the Boot screen.
➋
The primary operating system starts automatically if the Auto Start
option is enabled in CMOS Setup.
➌
The primary operating system can be selected in the Operating
System Selection Setup screen.
Follow this procedure to designate a new primary operating system:
1. From the AlphaBIOS Setup screen select Utilities. In the selection box
that is displayed, choose OS Selection Setup.
2. The Operating System Selection Setup screen is displayed. Select the
primary operating system from the list displayed.
AlphaBIOS Console
3-37
3.9.2
Primary Operating System and the Auto Start Option
The process of setting up your operating system selections is
similar to using an editor. You can make changes to your
operating system selections and then either save your changes
or exit without saving.
Figure 3–25 Operating System Selection Setup
Operating System Selection Setup
Windows NT Server 4.0
2
3
4
5
1
Primary Operating System
Boot Name: Windows NT Server 4.0
Boot File: Disk 0, Partition 2
\os\winnt400\osloader.exe
OS Path:
Disk 0, Partition 1
\WINNT400
OS Options:
6
INSERT=New
DEL=Delete
F6=Edit
F7=Copy
F8=Primary
F9=Validate
ESC=Discard Changes
F10=Save Changes
PK-0737C-97
AlphaBIOS boots Windows NT in two stages. The first stage involves reading
an OS Loader program from a disk. The OS Loader program is named
OSLOADER.EXE. The selection for the operating system must describe the
path where AlphaBIOS will find the OS Loader program. The OS Loader
program must be located on a partition formatted with the FAT file system.
Once the OS Loader program executes, it uses the services provided by
AlphaBIOS to load the operating system components. After the operating
system is loaded, the OS Loader starts execution of the operating system.
3-38 DS10 Console Reference
➊ Primary operating system — The OS that appears first on the
AlphaBIOS Boot screen. It is also the version of the OS that
automatically starts if Auto Start is selected. Any of the operating
system selections can be the primary operating system.
➋ Boot name — Each boot name is associated with an operating system
selection. Windows NT setup automatically creates a boot name each
time you install the operating system. Because the boot name is only a
name, you can modify it at any time without affecting the rest of the
operating system selection. The boot name must have at least one
character.
➌ Boot file — Describes the disk, partition, path, and name of the file that
AlphaBIOS passes control to during the process of starting the operating
system. This setting is created along with the operating system selection
during Windows NT setup, and the user does not usually modify it.
However, this setting can be modified if necessary. For example, a
developer testing different versions of OSLOADER.EXE can store the
different versions in different locations and modify this line to start the
operating system with the different versions as needed.
During Operating System Selection Setup, you can select the disk
and partition for the location of the boot file from a list of choices
presented in a list box. To open a list of values for the field, press the Alt
and down arrow keys together. When you select a boot file location and
name, AlphaBIOS searches for the specified program on the specified
partition. If the search fails, a warning is displayed, saying that the file
does not exist. You are given the choice to continue with the changes
anyway or to cancel the operation and fix the problem.
➍ OS path — Describes the disk, partition, and path to the operating
system root directory for an operating system selection.
During Operating System Selection Setup, you can select the disk
and partition for the location of the boot file from a list of choices
presented in a list box. To open a list of possible values for the field,
press the Alt and down arrow keys at the same time. When you select or
enter an OS path, AlphaBIOS searches for the directory. If the search
fails, a warning is displayed, saying that the directory does not exist.
You are given the choice to continue with the changes anyway or to
cancel the operation and fix the problem.
AlphaBIOS Console
3-39
➎ OS options — Lists the startup parameters passed to the operating
system for an operating system selection. One example of a startup
parameter is whether to start the operating system in debug mode. By
default, Windows NT does not add any entries to this field. This field
can be modified.
➏ Operating System Selection Setup options — You can use the
options listed at the bottom of the screen to edit operating system
selections. When you edit an OS selection, the fields of the OS selection
are validated when you exit the OS Selection Setup screen.
Depending on the option you choose, one of the following dialog boxes
will display.
New OS selection (Insert key) — Displays the Insert New Operating
System Selection dialog box, with default values for the new OS
selection already filled in. You can change these values as necessary.
Delete OS selection (Delete key) — Tags the currently selected OS
selection for deletion. Although the OS selection is removed from the
screen, it is not actually deleted until you save changes.
You can also delete all of your OS selections at once by pressing the
Control and Delete keys at the same time while in the Operating
System Selection Setup screen.
NOTE: If you delete all the OS selections, a dialog box is displayed
informing you that no OS selections exist and offering three
options. You can create a new OS selection, exit without saving
changes, or exit and save changes.
Edit OS selection (F6 key) — Edit all values of an OS selection by
selecting the OS selection to edit and pressing F6. A dialog box is
displayed with current information. You can then edit the OS selection
fields.
Copy OS selection (F7 key) — Create a new OS selection by using an
existing OS selection as a template. Select the OS selection you want to
copy and press F7. A dialog box is displayed with the values of your OS
selection. You can then edit the OS selection fields. If you do not make
any changes, a duplicate copy of the OS selection you copied is made.
3-40 DS10 Console Reference
Primary operating system (F8 key) — Sets the selected OS selection as
the primary operating system. When you make an OS selection
primary, it is displayed first on the Operating System Selection
Setup screen with the text “Primary Operating System.” In addition,
the primary operating system is displayed first on the AlphaBIOS
Boot screen and is automatically started if Auto Start is enabled.
Validate OS selection (F9 key) — Validates the fields in the currently
selected OS selection. The validation routine checks that the OS loader
file and OS directory fields contain valid paths and that the
OSLOADER.EXE file exists in the directory specified. At the end of the
validation, a dialog box is displayed describing the results of the
validation. If there is an error in an OS selection, the validation
routine displays a dialog box describing the component of the OS
selection that is in error. At this point you can choose to edit the OS
selection to correct the error, or delete the OS selection altogether.
You can also validate all OS selections at once by pressing the Control
and F9 keys at the same time. All OS selections are validated in the
order they are listed on screen.
Discard changes (Escape key) — Returns to the AlphaBIOS Setup
screen without saving changes.
Save changes (F10 key) — Saves changes and returns to the
AlphaBIOS Setup screen.
AlphaBIOS Console
3-41
3.10 Switching from AlphaBIOS to SRM Console
You can run firmware-based diagnostics from the SRM console.
You must be in the SRM to boot OpenVMS or UNIX. To switch
from AlphaBIOS to the SRM console, press the Halt/Reset button
on the control panel, and the system will power up. Press the
Halt/Reset button as the system is going through self-tests and
you will be at the SRM console.
Alternatively, select Tru64 UNIX (SRM) or OpenVMS (SRM) from
the Advanced CMOS Setup screen and reset the system.
Figure 3–26 Switching to the SRM Console
Advanced CMOS Setup
PCI Parity Checking:
Disabled
Power-up Memory Test:
Enabled
AlphaBIOS Password Option:
Console Selection:
F1=Help
Disabled
Digital UNIX Console (SRM)
Console (AlphaBIOS)
Power-up Memory Test Windows
Length: NTFull
OpenVMS Console (SRM)
Digital UNIX Console (SRM)
Press
or
to select the firmware console that will be presented
the next time the system is power-cycled.
ESC=Discard Changes
F10=Save Changes
PK-0750B-96
3-42 DS10 Console Reference
Firmware-based diagnostics are run from the SRM console. To boot Tru64
UNIX or OpenVMS, you need to change the Halt/Reset jumper on the
motherboard (see Appendix A).
Follow this procedure to switch from AlphaBIOS to SRM:
1. In AlphaBIOS, select CMOS Setup and press Enter.
2. In the CMOS Setup screen press F6. The Advanced CMOS Setup screen
is displayed.
3. Select Tru64 UNIX console (SRM) or OpenVMS console (SRM) and
press F10.
4. The CMOS Setup screen is displayed. Press F10 to save the change.
5. Reset the system by powering off and then on again for the changes to take
effect.
To return to the AlphaBIOS console, issue the alphabios or nt command at the
SRM console prompt.
AlphaBIOS Console
3-43
3.11 Running Utility Programs
Maintenance programs such as RAID configuration utilities are
run from the AlphaBIOS Utilities menu.
Figure 3–27 Run Maintenance Program Dialog Box
PK14656-98
➊ Program name — The program to be run. It must be an executable
program with an .EXE extension. It is not necessary to type the
extension. Programs run from AlphaBIOS must be written as ARC
compatible images.
➋ Location — The location from which the program in the Program Name
field will be run if no path is entered along with the program name. To
display a list of available disks and partitions, press the Alt and down
arrow keys at the same time. Once the list is displayed, use the arrow
keys to cycle through the selections.
3-44 DS10 Console Reference
3.11.1
Running Utilities from a Graphics Monitor
1. Start AlphaBIOS Setup. If the system is in the SRM console, set the SRM
console environment variable to graphics and issue the command
alphabios.
2. From AlphaBIOS Setup, select Utilities, then select Run Maintenance
Program from the submenu that is displayed, and press Enter. See Figure
3–28.
3. In the Run Maintenance Program dialog box (Figure 3–27), type the
name of the program to be run in the Program Name field. Then Tab to the
Location list box, and select the hard disk partition, floppy disk, or CD-ROM
drive from which to run the program.
4. Press Enter to execute the program.
Figure 3–28 AlphaBIOS Utilities Menu
PK1467-98
AlphaBIOS Console
3-45
3.11.2
Running Utilities from a Serial Terminal
Utilities are run from a serial terminal in the same way as from a monitor with
graphics capabilities enabled. The menus are the same, but some keys are
different.
Table 3-1 AlphaBIOS Option Key Mapping
AlphaBIOS Key
VTxxx Key
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
Insert
Delete
Backspace
Escape
Ctrl/A
Ctrl/B
Ctrl/C
Ctrl/D
Ctrl/E
Ctrl/F
Ctrl/P
Ctrl/R
Ctrl/T
Ctrl/U
Ctrl/V
Ctrl/W
Ctrl/H
Ctrl/[
1. Start AlphaBIOS Setup by issuing the command alphabios.
2. Press F2 in the AlphaBIOS Boot screen.
3. From AlphaBIOS Setup, select Utilities, and select Run Maintenance
Program from the submenu that is displayed. Press Enter.
4. In the Run Maintenance Program dialog box, type the name of the
program to be run in the Program Name field. Then tab to the Location list
box, and select the hard disk partition, floppy disk, or CD-ROM drive from
which to run the program.
5. Press Enter to execute the program.
3-46 DS10 Console Reference
Chapter 4
Remote Management Console
The remote management console (RMC) provides a command-line user interface
for entering commands to monitor and control the system. In addition to doing
routine monitoring, you can invoke the command-line interface to perform
remote power on/off, halt, and reset.
The RMC can detect alert conditions such as overtemperature, fan failure, and
power supply failure and automatically dial a pager phone number or another
computer system to notify the remote operator of the alert condition.
This chapter explains the operation and use of the RMC. Sections are:
•
RMC Components
•
Remote Halt (In/Out)
•
Terminal Setup
•
Configuring Remote Dial-In
•
Operating Modes
•
Configuring Dial-Out Alert
•
Entering the RMC
•
Dialing In
•
SRM Environment
Variables for COM1
•
Resetting RMC to Factory
Defaults
•
Status Monitoring
•
Troubleshooting Tips
•
Remote Power (On/Off)
•
RMC Commands
Remote Management Console
4-1
4.1
RMC Components
The RMC resides in an independent microprocessor on the
system motherboard and allows a remote operator to connect to
the system COM1 port from a modem or from a serial terminal
or terminal emulator.
Figure 4–1 Location of RMC Components on Motherboard
RMC PIC
Processor
1
1
RMC
Jumper
Halt/Reset
Jumper
PK0246b
The RMC logic is implemented using an 8-bit microprocessor, PIC17C44, as the
primary control device. The RMC PIC is programmed with code to control
access to various environmental status bits.
You can gain access to the RMC as long as AC power is available to the system
(through the wall outlet). Thus, if the system fails, you can still access the RMC
and gather information about the failure. The jumper position shown in Figure
4–1 is the default position set in manufacturing which enables the RMC.
4-2
DS10 Console Reference
4.2
Terminal Setup
Remote connection is made through a modem connected to the
COM1 port. To set up the modem, you first use a local terminal
on the COM1 port to set up the parameters of the modem and
RMC connection. You then disconnect the terminal and connect
the modem.
Figure 4–2 Setups for RMC Mode
VT
1
A
B
2
1
PK1051
You can connect a terminal or a modem to the COM1 port, but not both at the
same time. You use the terminal to set RMC parameters for the connection,
then connect the modem. See Section 4.9.
Remote Management Console
4-3
4.3
Operating Modes
RMC runs in three modes on this system: Snoop, soft bypass, and
firm bypass. The bypass modes are set with the set com1_mode
command from the SRM console.
Figure 4–3 Bypass Mode
System
COM1
SRM/AlphaBIOS
Consoles
Operating System
DUART
COM1 Port
UART
RMC PIC
Processor
Bypass
Modem Port
UART
RMC COM1
Port (Local)
Modem
RMC>
Local Serial Terminal
(MMJ Port)
Modem
RMC>
Remote Serial Terminal
or Terminal Emulator
PK0908b
NOTE: The internal system COM1 port should not be confused with the
external COM1 serial port on the back of the system. The internal
COM1 port is used by software to send data either to the COM1 port on
the system or to the RMC modem port if a modem is connected.
4-4
DS10 Console Reference
Snoop Mode (Default Mode)
In snoop mode data partially bypasses the RMC. The data and control signals
are routed from the system COM1 port to the external modem port, but the
RMC taps into the data lines and listens passively for the RMC escape
sequence. If it detects the escape sequence, it enters RMC mode.
The escape sequence is also delivered to the system on the bypassed data lines.
If you decide to change the default escape sequence, be sure to choose a unique
sequence so that the system software does not interpret characters intended for
the RMC.
Because snoop mode does not filter every piece of data, it is useful when you
want to monitor the system but also ensure optimum COM1 performance.
Bypass Modes
In bypass modes, note that the internal system COM1 port is connected directly
to the modem port. The RMC passively listens to the escape sequence from the
external COM1 port, when the RMC escape sequence is captured.
Soft Bypass Mode
In soft bypass mode all data and control signals are routed directly from the
system COM1 port to the external modem port, and the RMC does not listen to
traffic on the COM1 data lines. If an alert condition or loss of carrier occurs,
however, the RMC detects it and switches automatically into snoop mode. In
soft bypass mode, the RMC also initializes the modem for dialing in and dials
out when an alert is detected.
Soft bypass mode is useful if management applications need the COM1 channel
to perform a binary download, because it ensures that RMC does not
accidentally interpret some binary data as the escape sequence.
Firm Bypass Mode
Firm bypass mode effectively disables the RMC. All data and control signals
are routed directly from the system COM1 port to the external modem port. In
firm bypass mode, the RMC dial-in and call-out features are disabled. Firm
bypass mode is useful if you want the system, or an application (such as Insight
Manager or ServerWorks)—not the RMC—to fully control the modem port and
you want to disable RMC features.
Remote Management Console
4-5
4.4
Entering the RMC
You type an escape sequence to invoke the RMC. You can enter
RMC from a modem or the local serial console terminal. You can
enter the RMC from the local terminal regardless of the current
operating mode. You can set up RMC parameters.
1. Invoke the RMC from a serial terminal by typing the following default
escape sequence:
^[^[ rmc
This sequence is equivalent to typing Ctrl/left bracket, Ctrl/left bracket, and
rmc. On some keyboards, the Esc key functions like the Ctrl/left bracket
combination.
To exit RMC, enter the quit command. This action returns you to
whatever you were doing before you invoked the RMC.
2.
4.5
SRM Environment Variables for COM1
Several SRM environment variables allow you to set up the
COM1 serial port for use with the RMC.
You may need to set the following environment variables from the SRM console,
depending on how you decide to set up the RMC. See Chapter 2 for information
on setting SRM environment variables.
Table 4–1 SRM Environment Variables for COM1
Variable
com1_baud
com1_flow
com1_mode
com1_modem
4-6
Function
Sets the baud rate of the COM1 serial/modem port. The
default is 9600.
Specifies the flow control on the serial port. The default is
software.
Specifies the COM1 data flow paths so that data either
flows through the RMC or bypasses it. This environment
variable can be set from either the SRM or the RMC.
Specifies to the operating system whether or not a modem
is present.
DS10 Console Reference
4.6
Status Monitoring
Use the RMC status command to check the current state of the
system’s sensors as well as the current escape sequence and
alarm information.
40%8*36178%897
*MVQ[EVI6IZMWMSR:
7IVZIV4S[IV32
61',EPX(IEWWIVXIH
61'4S[IV'SRXVSP32
4S[IV7YTTP]3/
7]WXIQ*ERW3/'49*ER3/
8IQTIVEXYVI®'[EVRMRKWEX®'TS[IVSJJEX®'
)WGETI7IUYIRGIB?B?61'
6IQSXI%GGIWW(MWEFPIH
61'4EWW[SVHWIX
%PIVX)REFPI(MWEFPIH
%PIVX4IRHMRK=)7
-RMX7XVMRK%8*):7!
(MEP7XVMRK%8<(8
%PIVX7XVMRK
'SQCQSHI72334
0EWX%PIVX%'0SWW
;EXGLHSK8MQIVWIGSRHW
%YXSVIFSSX3**
0SKSYX8MQIVQMRYXIW
9WIV7XVMRK
Table 4–2 Status Command Fields
Field
Firmware Revision
Server Power
RMC Halt
Meaning
Revision of RMC firmware on the microcontroller.
On = System is on.
Off = System is off.
Asserted = System has been halted.
Deasserted = Halt has been released from halt.
Continued on next page.
Remote Management Console
4-7
Table 4–2 Status Command Fields (Continued)
Power Control On = System has powered on from RMC.
Off = System has powered off from RMC.
Power Supply
System Fans
CPU Fan
Temperature
Escape Sequence
OK = PCI and system fan are operating.
FAIL = PCI or system fan failure has been detected.
OK = Fan on CPU chip is operating.
FAIL = CPU fan failure has been detected.
Reports current temperature and system limits.
Current escape sequence for access to RMC console.
Remote Access
Enable = Modem for remote access is enabled.
Disable = Modem for remote access is disabled.
RMC Password
Set = Password set for modem access.
Not set = No password set for modem access.
Alert Enable
Alert Pending
Init String
Dial String
Alert String
Enabled = Dial-out enabled for sending alerts.
Disabled = Dial-out is disabled for sending alerts.
Yes = Alert has been triggered.
No = No alert has been triggered.
Initialization string that was set for modem access.
Phone number dialed when an alert occurs.
Identifies the system that triggered the alert to the paging
service. Usually the phone number of the monitored system.
Com1_mode
Can be set to snoop, soft-bypass, or firm-bypass.
See Section 4.3.
Last Alert
Type of alert (for example, power supply failed).
Watchdog timer
Autoreboot
Logout Timer
User String
4-8
OK = Auxiliary 5V is working.
Reports time set by user using set wdt command; can be up
to 60 seconds in increments of 10. When it times out, alert is
sent.
ON = Autoreboot feature enabled.
OFF = Autoreboot feature disabled.
The amount of time before the RMC terminates an inactive
modem connection. The default is 20 minutes.
Notes supplied by user.
DS10 Console Reference
4.7
Remote Power (On/Off)
You can power a monitored system on or off from the RMC using
console monitor commands.
Figure 4–4 Power Button
PK1043b
Remote Power-On
The RMC power {on, off} commands can be issued remotely to power the
system on or off. They have the same function as the Power button on the
control panel. The Power button, however, has precedence.
•
If the system has been powered off with the Power button, the RMC cannot
power the system on.
•
If the system has been powered on with the Power button, and the power
off command is used to turn the system off, you can toggle the Power button
off, then on, to power the system back on.
When you issue the power on command, the terminal exits the RMC and
reconnects to the system’s COM1 port.
61'"TS[IVSR
6IXYVRMRKXS'31TSVX
61'"TS[IVSJJ
Remote Management Console
4-9
4.8
Remote Halt (In/Out)
You can issue a halt to a monitored system from the RMC using
console monitor commands. Under OpenVMS and Tru64 UNIX,
the system will halt. Under Windows NT, the command will be
ignored.
Figure 4–5 Halt/Reset Jumper
1
1
Setting for
OpenVMS
& Tru64 UNIX
Setting for
Windows NT
PK0246c
The RMC halt in command can be issued remotely to halt the system.
The RMC halt out command can be issued to deassert the halt.
These commands have the same function as the Halt button on the control
panel (see Figure 4–6) for OpenVMS and Tru64 Unix. The Halt button under
Windows NT operates differently because the Halt/Reset jumper is set
differently (see Figure 4–5).
4-10
DS10 Console Reference
Figure 4–6 Halt/Reset Button
PK1043c
Table 4–3 Halt/Reset Button Function under Operating Systems
Operating System
OpenVMS and
Tru64 UNIX
Windows NT
Function
Suspends the operating system and
returns control to the SRM or RMC console.
Resets the system.
The Halt button, however, does not override the halt {in, out} commands. If
you halt the system with halt in, you must use halt out to deassert the halt
state.
When you issue either the halt in or halt out command under OpenVMS or
Tru64 UNIX, the terminal exits the RMC and reconnects to the system’s COM1
port.
61'"LEPXMR
6IXYVRMRKXS'31TSVX
61'"LEPXSYX
6IXYVRMRKXS'31TSVX
Remote Management Console
4-11
4.9
Configuring Remote Dial-In
Before you can dial in through the RMC modem port or enable
the system to call out in response to system alerts, you must
configure the RMC for remote dial-in.
Connect your serial terminal to the COM1 port and turn it on. Set up the RMC
parameters. Then disconnect the serial terminal, connect the modem, and
check your configuration.
Example 4–1 Dial-In Configuration
61'"WIXTEWW[SVH
➊
61'4EWW[SVH
:IVMJMGEXMSR
61'"WIXMRMX
➋
-RMX7XVMRK%8*):<7!
61'"IREFPIVIQSXI
➌
1SHIQ[MPPFIIREFPIH[LIRMXMWGSRRIGXIH➍
61'"WXEXYW
➎
6IQSXI%GGIWW)REFPIH
NOTE: The following modems require the initialization strings shown here.
For other modems, see your modem documentation.
Modem
Initialization String
Motorola 3400 Lifestyle 28.8
AT&F0E0V0X0S0=2
AT &T Dataport 14.4/FAX
AT&F0E0V0X0S0=2
Hayes Smartmodem Optima 288
V-34/V.FC + FAX
AT&FE0V0X0S0=2
4-12
DS10 Console Reference
➊
Sets the password that is prompted for at the beginning of a modem
session. The string cannot exceed 14 characters and is not case sensitive.
For security, the password is not echoed on the screen. When prompted for
verification, type the password again.
➋
Sets the initialization string. The string is limited to 31 characters and
can be modified depending on the type of modem used. Because the
modem commands disallow mixed cases, the RMC automatically converts
all alphabetic characters entered in the init string to uppercase.
The RMC automatically configures the modem’s flow control according to
the setting of the SRM com1_flow environment variable. The RMC also
enables the modem carrier detect feature to monitor the modem
connectivity.
➌
Enables remote access to the RMC modem port by configuring the modem
with the setting stored in the initialization string.
➍
Because you have the serial terminal connected and not the modem, the
system responds that the modem will be enabled when it is connected.
➎
Verify the settings and check that the Remote Access field is set to
Enabled, ready for the modem to be connected.
➏
Disconnect the serial terminal, connect the modem and check that the
modem’s TR light is lit. See Section 4.11 for dialing in instructions.
Remote Management Console
4-13
4.10 Configuring Dial-Out Alert
When you are not monitoring the system through a modem
connection, you can use the RMC dial-out alert feature to
remain informed of system status. If dial-out alert is enabled,
and the RMC detects alarm conditions within the managed
system, it can call a preset pager number.
You must configure remote dial-in for the dial-out feature to be enabled. See
Section 4.9. To set up the dial-out alert feature, enter the RMC from the local
serial terminal.
Example 4–2 Dial-Out Alert Configuration
61'"WIXHMEP
(MEP7XVMRK%8<(8
61'"WIXEPIVX
%PIVX7XVMRK
61'"IREFPIEPIVX
1SHIQ[MPPFIIREFPIH[LIRMXMWGSRRIGXIH
61'"GPIEVEPIVX
61'"WIRHEPIVX
%PIVXHIXIGXIH
Disconnect the serial terminal and connect the modem at COM1 port.
You should receive an alert within 30 minutes of modem connection.
➊
➋
➌
➍
➎
# Once the alert is received, reconnect the serial terminal and clear the test alert.
61'"GPIEVEPIVX
61'"WXEXYW
%PIVX)REFPI)REFPIH
➏
➐
A typical alert situation might be as follows:
•
The RMC detects an alarm condition caused by excessive temperature.
•
The RMC dials the operator’s pager and sends a message identifying the
system.
•
The operator dials the system from a remote serial terminal.
•
The operator invokes the RMC, checks system status, and powers down the
managed system.
4-14
DS10 Console Reference
•
When the problem is resolved, the operator powers up and reboots the
system.
•
The dial-out alert feature is enabled as part of the dial-in setup. See
Section 4.9.
The elements of the dial string and alert string are shown in Table 4–4. Paging
services vary, so you need to become familiar with the options provided by the
paging service you will be using. The RMC supports only numeric messages.
➊
Sets the string to be used by the RMC to dial out when an alert condition
occurs. The dial string must include the appropriate modem commands to
dial the number. In this example, 1-508-555-3333 is the pager number.
➋
Sets the alert string, typically the phone number of the modem connected
to the remote system. The alert string is appended after the dial string,
and the combined string is sent to the modem when an alert condition is
detected. In this example, the system’s modem number is 1-508-555-4444.
➌
Enables the RMC to page a remote system operator.
Because the modem is not connected at the COM1 port at this time, the
RMC notifies you that the alert will be enabled at connection.
➍
Clears any alert that may be pending. This ensures that the send alert
command will generate an alert condition.
➎
Forces an alert condition. This command is used to test the setup of the
dial-out alert function. It must be issued from the local serial terminal.
The RMC tries to send the alert immediately. Because the modem is not
connected at the COM1 port at this time, the RMC resets the paging
interval to at most 30 minutes, and will send the alert again. If the pager
does not receive the alert within 30 minutes, re-check your setup.
➏
Clears the current alert so that the RMC can capture a new alert. The last
alert is stored until a new event overwrites it. The Alert Pending field of
the status command becomes NO after the alert is cleared.
➐
Verifies the settings. Check that the Alert Enable field is set to Enabled.
NOTE: If you do not want dial-out paging enabled at this time, enter the
disable alert command after you have tested the dial-out alert
function. Alerts continue to be logged, but no paging occurs.
Continued on next page
Remote Management Console
4-15
Table 4–4 Elements of Dial String and Alert String
Dial String
The dial string is case sensitive. The RMC automatically converts all
alphabetic characters to uppercase
ATXDT
AT = Attention.
X = Forces the modem to dial “blindly” (not seek the dial
tone). Enter this character if the dial-out line modifies its
dial tone when used for services such as voice mail.
D = Dial
T = Tone (for touch-tone)
9,
The number for an outside line (in this example, 9). Enter
the number for an outside line if your system requires it.
, = Pause for 2 seconds.
15085553333
Phone number of the paging service.
Alert String
,,,,,,
Each comma (,) provides a 2-second delay. In this example,
a delay of 12 seconds is set to allow the paging service to
answer.
5085553332#
A call-back number for the paging service. The alert string
must be terminated by the pound (#) character.
;
A semicolon (;) must be used to terminate the entire string.
4-16
DS10 Console Reference
4.11 Dialing In
To start a remote monitoring session, dial in, using the dial
string you entered during the setup procedure. Enter the RMC
modem password, and then type the escape sequence.
1. After completing the setup procedure, dial in, enter the RMC password at
the Modem password: prompt. When a prompt is displayed, type the escape
sequence. In the following example, the system is at the SRM console when
the modem connection is made.
%8(8
6-2+-2+
6-2+-2+
'322)'8%65:0%41
1SHIQTEWW[SVH
;IPGSQIXS61':
"""B?B?VQG
61'"
(sequence is not echoed)
2. At the RMC> prompt, enter commands to monitor and control the remote
system.
3. When you have finished your modem session, enter the hangup command
to cleanly terminate the modem session and disconnect from the system.
Remote Management Console
4-17
4.12 Resetting the RMC to Factory Defaults
If the RMC escape sequence is set to something other than the
default, and the sequence has been lost or forgotten, the RMC
must be reset to factory settings to restore the default escape
sequence. See Appendix A.
Figure 4–7 RMC Jumpers (Default Positions)
RMC PIC
Processor
1
RMC
Jumper
PK0246c
WARNING: To prevent injury, access is limited to persons who have
appropriate technical training and experience. Such persons are expected
to understand the hazards of working within this equipment and take
measures to minimize danger to themselves or others.
4-18
DS10 Console Reference
4.13 Troubleshooting Tips
Table 4–5 lists possible causes and suggested solutions for
symptoms you might see.
Table 4–5 RMC Troubleshooting
Symptom
Possible Cause
Suggested Solution
If you are not at the RMC prompt, a system reset or initialization disconnects
the modem.
SRM clears modem
connections on power-up.
Reconnect the modem.
See Section 4.11.
RMC does not answer when the modem is called.
Modem cables may be
incorrectly installed.
Check modem phone lines
and connections.
RMC remote access is
disabled.
Enter enable remote
access command from
RMC.
RMC does not have a valid
password set.
Enter set password and
enable remote commands
from the RMC.
On power-up, the RMC defers
initializing the modem for 30
seconds to allow the modem to
complete its internal diagnostics and initializations.
Wait 30 seconds after
powering up the system
and the RMC before
attempting to dial in.
Modem may have had power
cycled since last being initialized or modem is not set up
correctly.
Enter enable remote
command from the RMC
console.
Continued on next page.
Remote Management Console
4-19
Table 4–5 RMC Troubleshooting (Continued)
Symptom
Possible Cause
Suggested Solution
After the system is powered up, the COM1 port seems to hang and then
starts working after a few seconds.
This delay is normal.
Wait a few seconds for
the COM1 port to start
working.
New password and escape sequence are forgotten.
RMC console must be
reset to factory defaults.
See Section 4.12.
The remote user sees a “+++” string on the screen.
The modem is confirming
whether the modem has really
lost carrier
This is normal
behavior.
The message “unknown command” is displayed when the user enters a
carriage return by itself.
The terminal or terminal
emulator is including a line
feed character with the
carriage return.
Change the terminal or
terminal emulator
setting so that “new
line” is not selected.
Cannot enable modem or modem will not answer.
The modem is not configured
correctly to work with the
RMC.
4-20
DS10 Console Reference
Modify the modem
initialization string
according to your
modem documentation.
4.14 RMC Commands
The remote management console supports setup commands and
commands for remotely managing the system.
clear {alert, port}
disable (alert, reboot, remote)
enable (alert, reboot, remote)
halt {in, out}
hangup
help or ?
power {on, off}
quit
reset
send alert
set {alert, com1_mode, dial, escape, init, logout, password, user, wdt}
status
Remote Management Console
4-21
Command Conventions
Observe the following conventions for entering RMC commands:
•
Enter enough characters to distinguish the command.
NOTE: The reset and quit commands are exceptions.
You must enter the entire word for these commands to work.
•
For commands consisting of two words, enter the entire first word and at
least one letter of the second word. For example, you can enter disable a
for disable alert.
•
For commands that have parameters, you are prompted for the parameter.
•
Use the Backspace key to erase input.
•
If you enter a nonexistent command or a command that does not follow
conventions, the following message is displayed:
)6636YRORS[RGSQQERH
•
If you enter a string that exceeds 14 characters, the following message is
displayed:
)6636SZIVJPS[
4-22
DS10 Console Reference
4.14.1 clear alert
The clear alert command clears the current alert condition and
causes the RMC to stop paging the system operator at the
remote location.
If the alert is not cleared, the RMC continues to page the remote operator every
30 minutes if both remote access and alerts are enabled.
The clear alert command clears the current alert so that the RMC can capture
a new alert. The last alert is stored until a new event overwrites it. The Alert
Pending field of the status command becomes NO after the alert is cleared.
Syntax:
clear alert
4.14.2 clear port
The clear port command uses the console port modem control
signals to clear any “stuck” conditions on the system’s COM1
port.
The clear port command attempts to free the port by resetting all UARTs
controlled by the RMC if the port is currently locked by an application program,
without resetting the entire system.
Syntax:
clear port
NOTE: This command also causes the modem to disconnect.
4.14.3 disable alert
The disable alert command disables the RMC from paging a
remote system operator.
Monitoring continues and alerts are still logged in the Last Alert field of the
status command, but alerts are not sent to the remote operator.
Syntax:
disable alert
Remote Management Console
4-23
4.14.4 disable remote
The disable remote command disables remote access to the RMC
modem port and disables automatic dial-out alerts.
Syntax:
disable remote
4.14.5 enable alert
The enable alert command enables the RMC to page a remote
system operator.
Before you can enter the enable alert command, you must configure remote
dial-in and call-out, set an RMC password (set password command), and
enable remote access (enable remote command) to the RMC modem port.
Syntax:
Example:
enable alert
61'"WIXHMEP
(MEP7XVMRKEX\HX
61'"WIXEPIVX
%PIVX7XVMRK
61'"IREFPIEPIVX
1SHIQ[MPPFIIREFPIH[LIRMXMWGSRRIGXIH
The system notifies you that when you connect the modem (after disconnecting
the serial terminal at the COM1 port), the alert will be enabled. Before you
connect the modem, you can issue the status command to see if the Alert
Enable field is set to Enabled.
If the enable alert command fails, the following error message is displayed:
)6636IREFPIJEMPIH
.
4-24
DS10 Console Reference
4.14.6 enable remote
The enable remote command enables remote access to the RMC
modem port by configuring the modem with the setting stored in
the initialization string.
This command also allows the RMC to automatically dial the phone number set
with the set dial command upon detection of alert conditions.
Before you can enter the enable remote command, you must configure remote
dial-in by setting an RMC password (set password command) and initialization string. The enable remote command remains in effect until you enter the
disable remote command.
Syntax:
Example:
enable remote
61'"WIXTEWW[SVH
61'4EWW[SVH
:IVMJMGEXMSR
61'"WIXMRMX
-RMX7XVMRK%8*):<7!
61'"IREFPIVIQSXI
1SHIQ[MPPFIIREFPIH[LIRMXMWGSRRIGXIH
The system notifies you that when you connect the modem (after disconnecting
the serial terminal at the COM1 port), remote access will be enabled. Before you
connect the modem, you can issue the status command to see if the Remote
Access field is set to Enabled.
If the enable remote command fails, the following error message is displayed:
)6636IREFPIJEMPIH
Remote Management Console
4-25
4.14.7 halt (in/out)
You can issue a halt to a monitored system from RMC using
console monitor commands.
The effect of this command
depends on the setting of the HALT/RESET jumper on the
motherboard. See Section 4.8 for a full discussion of this
feature.
The halt in command is equivalent to pressing the Halt button on the control
panel. The effect depends on which operating system you are running, and how
the Halt/Reset switch is set. The default settings are:
Operating System
OpenVMS and
Tru64 UNIX
Windows NT
Function
Suspends the operating system and
returns control to the SRM or RMC console.
Resets the system.
The operator at the control panel can override the halt in command by pressing
the Power button.
Syntax:
halt in
halt out
Example:
61'"LEPXMR
6IXYVRMRKXS'31TSVX
NOTE: The halt in command does not halt systems running Windows NT.
However, if you power up after the halt in command has been issued,
the system stops in the SRM console. To load AlphaBIOS, issue the halt
out command before powering up.
You cannot use halt out to release a halt if the Halt button on the control panel
is latched in. If you issue the command, the following message is displayed:
61'"LEPXSYX
,EPXFYXXSRMW-2
4-26
DS10 Console Reference
4.14.8 hangup
The hangup command terminates the modem session.
If you do not issue the hangup command, the session is disconnected
automatically after a period of idle time set by the set logout command. The
default is 20 minutes
Syntax:
hangup
4.14.9 help or ?
The help or ? command displays the RMC command set.
Syntax:
Example:
help or ?
61'"LIPT
GPIEV_EPIVXTSVXa
HMWEFPI_EPIVXVIFSSXVIQSXIa
IREFPI_EPIVXVIFSSXVIQSXIa
LEPX_MRSYXa
LERKYT
LIPTSV#
TS[IV_SJJSRa
UYMX
VIWIX
WIRHEPIVX
WIX_EPIVXGSQCQSHIHMEPIWGETIMRMXPSKSYXTEWW[SVHYWIV[HXa
WXEXYW
4.14.10 power off
The power off command is equivalent to turning off the system
power from the control panel.
If the system is already powered off, this command has no effect. You can
override the power off command either by issuing a power on command or by
toggling the Power button on the control panel.
Syntax:
power off
Remote Management Console
4-27
4.14.11 power on
The power on command is equivalent to turning on the system
power from the control panel.
If the system is already powered on, this command has no effect. After the
power on command is issued, the user’s terminal exits the RMC and
reconnects to the system’s COM1 port.
Syntax:
Example:
power on
61'"TS[IVSR
6IXYVRMRKXS'31TSVX
The power on command does not turn on the system if the Power button on the
control panel is in the OFF position. Check the Power button if you issue the
power on command and receive the following message:
61'"TS[IVSR
*EMPIHXSTS[IVSR
4.14.12 quit
The quit command exits RMC from a serial terminal and returns
the user’s terminal to the system’s COM1 port.
You must enter the entire word for the command to take effect.
Syntax:
Example:
quit
61'"UYMX
6IXYVRMRKXS'31TSVX
4-28
DS10 Console Reference
4.14.13 reset
The reset command is equivalent to pushing the Reset button on
the control panel.
The reset command restarts the system. The terminal exits RMC and
reconnects to the server’s COM1 port. You must enter the entire word for the
command to take effect.
Syntax:
Example:
reset
61'"VIWIX
6IXYVRMRKXS'31TSVX
4.14.14 send alert
The send alert command forces an alert condition.
This command is used to test the setup of the alert dial-out function, sending an
alert condition to the pager or the phone.
However, since your serial terminal is connected while you are entering the
command, initially the alert will not be able to be sent. When the RMC cannot
page the operator, it may be that the modem or terminal is in use. The RMC
waits approximately 30 minutes, and then resends the alert. This allows you to
connect the modem, and wait for the alert string.
If the pager does not receive the alert after a half an hour, re-check your setup.
Syntax:
Example:
send alert
61'"WIRHEPIVX
%PIVXHIXIGXIH
Remote Management Console
4-29
4.14.15 set alert
The set alert command sets the alert string that is transmitted
through the modem when an alert condition is detected.
Set the alert string to the phone number of the modem connected to the remote
system. The alert string is appended after the dial string, and the combined
string is sent to the modem.
The alert string cannot exceed 63 characters, and consists of the following
elements:
,,,,,, Each comma (,) provides a 2-second delay. In this example, a
delay of 12 seconds is set to allow the paging service to
answer.
5085554444#
A call-back number for the paging service. The alert string
must be terminated by the pound (#) character.
;
A semicolon (;) must be used to terminate the entire string.
The example shown below is generic. Because paging services vary, be sure to
listen to the options provided by the paging service to determine the appropriate
delay and the menu options.
Syntax:
Example:
set alert
61'"WIXEPIVX
EPIVX"
4-30
DS10 Console Reference
4.14.16 set com1_mode
The set com1_mode command specifies the COM1 data flow
paths, so that data either passes through the RMC or bypasses it.
See Section 4.3 for descriptions of the RMC modes.
set com1_mode value
Syntax:
where value can be:
snoop
soft_bypass
firm_bypass
Data partially bypasses the RMC, but the RMC taps into the
data lines and listens passively for the RMC escape sequence.
Data bypasses RMC, but the RMC switches automatically into
snoop mode if an alert condition or loss of carrier occurs.
Data bypasses the RMC. The RMC is effectively disabled.
Example:
"""WIXGSQCQSHI
'31C13()7233473*8C&=4%77*-61C&=4%77
Remote Management Console
4-31
4.14.17 set dial
The set dial command sets the dial string to be used by the RMC
to dial out when an alert condition occurs.
The dial string must be in the correct format for the attached modem. If a
paging service is to be contacted, the dial string must include the appropriate
modem commands to dial the number, wait for the line to connect, and send the
appropriate touch tones to leave a pager message. The dial string is limited to
31 characters.
Because the modem commands do not allow mixed cases, the RMC converts all
alphabetic characters in the dial string to uppercase.
Syntax:
Example:
set dial
61'"WIXHMEP
(MEP7XVMRK%8<(8
where:
ATXDT
AT = Attention.
X = Forces the modem to dial “blindly” (not seek the dial
tone). Enter this character if the dial-out line modifies its
dial tone when used for services such as voice mail.
D = Dial
T = Tone (for touch-tone)
9,
The number for an outside line (in this example, 9). Enter
the number for an outside line if your system requires it.
, = Pause for 2 seconds.
15085553333
4-32
Phone number of the paging service. (In this example it is 1–
area code 508 – exchange 555 – number 3333.)
DS10 Console Reference
4.14.18 set escape
The set escape command changes the escape sequence used for
invoking the RMC.
The escape sequence can be any character string, not to exceed 14 characters. A
typical sequence consists of two or more control characters. It is recommended
that control characters be used in preference to ASCII characters. Use the
status command to verify the escape sequence.
Be sure to record the new escape sequence. If you forget the escape sequence,
you must reset the RMC to the factory defaults. See Section 4.12 for
information on setting the RMC to the factory defaults.
The following example consists of two instances of the Esc key and the letters
“FUN.” The “F” is not displayed when you set the sequence because it is
preceded by the escape character. Enter the status command to see the new
escape sequence.
Syntax:
Example:
set escape
61'"WIXIWGETI
)WGETI7IUYIRGIYR
61'"WXEXYW
)WGETI7IUYIRGIB?B?*92
Remote Management Console
4-33
4.14.19 set init
The set init command sets the modem initialization string.
The initialization string is limited to 31 characters and can be modified
depending on the type of modem used.
Syntax:
set init
Some typical initialization strings are:
Initialization String
Modem
at&f0e0v0x0s0=2
Motorola 3400 Lifestyle 28.8
at&f0e0v0x0s0=2
AT &T Dataport 14.4/FAX
at&fe0v0x0s0=2
Hayes Smartmodem Optima 288 V-34/V.FC + FAX
Example:
61'"WIXMRMX
-RMX7XVMRKEXJIZ\W!
61'"
Because the modem commands do not allow mixed cases, the RMC converts all
alphabetic characters entered in the init string to uppercase.
The RMC configures the modem’s flow control according to the setting of the
SRM com1_flow environment variable. The RMC also enables the modem
carrier detect feature to monitor the modem connectivity.
4-34
DS10 Console Reference
4.14.20 set logout
The set logout command sets the amount of time before the RMC
terminates an inactive modem connection. The default is 20
minutes.
The settings are in tens of minutes, 0–9. The zero (0) setting disables logout.
With logout disabled, the RMC never disconnects the idle modem session.
The following example sets the logout timer to 50 minutes.
Syntax:
Example:
set logout
61'"WIXPSKSYX
0SKSYX8MQIXIRWSJQMRYXIW
4.14.21 set password
The set password command allows you to set or change the
password that is prompted for at the beginning of a modem
session.
A password must be set to enable access through a modem. The string cannot
exceed 14 characters. For security, the password is not echoed on the screen.
When prompted for verification, type the password again. If you mistype,
reenter the set password command.
Syntax:
Example:
set password
61'"WIXTEWW
61'4EWW[SVH
:IVMJMGEXMSR
)6636:IVMJMGEXMSRJEMPIHTEWW[SVHMWRSXWIX
61'"WIXTEWW
61'4EWW[SVH
:IVMJMGEXMSR
Remote Management Console
4-35
4.14.22 set user
The set user command allows you to set a user string to be
displayed in the status command.
You may want to make notes regarding the system. The string is limited to 63
characters and is displayed in the User String field when you enter the status
command. In this example, the operator leaves a reminder that the power
supply needs to be replaced.
Syntax:
Example:
set user
61'"WIXYWIV
9WIV7XVMRKRIIHXSVITPEGI47
4.14.23 set wdt
The watchdog timer is a value up to 60 seconds, in increments of
10, set by the user, that can be used by software. This feature is
not currently used in any applications or operating systems.
Syntax:
Example:
set wdt
61'"WIX[HX
4.14.24 status
The status command displays the system status and the current
RMC settings.
Table 4–2 describes each field of the status command output.
Syntax:
Example:
4-36
status
See Section 4.6 for an example of the status command output.
DS10 Console Reference
Appendix A
Setting Jumpers
This appendix gives information on the correct settings of the jumpers on the
DS10 motherboard. If you are switching to Windows NT from OpenVMS or
Tru64 UNIX, you may want to change the HALT jumper.
Sections include:
•
Warnings and Cautions
•
Remove Power from the System
•
Open the System
•
Remove the Floppy Disk Enclosure
•
Set Jumpers
•
Restore Power
Setting Jumpers A-1
A.1
Warnings and Cautions
WARNING: To prevent injury, access is limited to persons
who have appropriate technical training and experience. Such
persons are expected to understand the hazards of working
within this equipment and take measures to minimize danger
to themselves or others.
The CPU module, RMC PIC processor, and memory modules
have parts that operate at high temperatures. Wait 2 minutes
after power is removed before touching any module.
Always wear a grounded wrist strap when servicing internal
components of the system
CAUTION: To reduce the risk of electrical shock or damage to
the equipment, do not disable the power cord grounding plug.
The grounding plug is an important safety feature. Plug the
power cord into a grounded (earthed) electrical outlet that is
easily accessible at all times. Disconnect power by unplugging
the power cord from the electrical outlet or the system
ACHTUNG: Um Verletzungen zu vermeiden, ist der Zugriff
nur Personen gestattet, die eine entsprechende technische
Schulung vorweisen können und über die notwendige
Erfahrung verfügen. Des weiteren sollten die Gefahren, denen
diese Personen bei der Arbeit mit dem Gerät ausgesetzt sein
könnten, bekannt sein, und die folgenden notwendigen Schritte
eingeleitet werden, um das Gefahrenrisiko für sowohl diese als
auch andere Personen zu minimieren:
1. Entfernen Sie leitfähigen Schmuck.
2. Schalten Sie das System vor dem Zugriff auf den
Systemkartenbehälter aus. Warten Sie zwei Minuten, bis sich
die Komponenten abgekühlt haben.
3. Tragen Sie bei der Berührung von internen Komponenten
ein Antistatikarmband.
A-2 DS10 Console Reference
A.2
Remove Power from the System
Be sure to remove the AC power cord from either the wall outlet
or the system cabinet. Power remains active in the RMC PIC
processor when the system is powered off using only the control
panel power switch. Also the CPU and memory modules have
parts that operate at high temperatures. Wait 2 minutes after
power is removed before touching any module.
Figure A–1 Removing Power from the System
115V
230V
PK1047a
1. Turn off the system and all external peripheral devices.
2. Unplug the system from the wall outlet.
3. Wait at least 15 seconds, to allow time for the power supply capacitors to
fully discharge.
4. Wait 2 minutes after power is removed before touching any module.
Setting Jumpers A-3
A.3
Open the System
Remove the cover to gain access to the system. See Figure A–2.
Figure A–2 Opening the System Cabinet
1
2
3
PK1021a-99
1. Unlock the top cover ➊.
2. Loosen the captive screw at the top of the bulkhead ➋.
3. Push down on the lever to the right of the screw and pull it out,
perpendicular to the system.
4. Slide the cover toward the back of the system ➌. Lift it off.
A-4 DS10 Console Reference
A.4
Remove the Floppy Disk Enclosure
To access the jumpers, remove the floppy disk drive enclosure.
Figure A–3 Removing the Floppy Disk Enclosure
1
2
PK1018-99
1. Hold on to the cylinder pins, which secure the floppy disk enclosure. Pull
the pins toward the center (see Figure A–3 ➊).
2. Pull the floppy drive unit back and up ➋.
3. Place the unit on top of the CD-ROM drive. You do not need to remove the
cables. Cable lengths have been designed to move the unit out of the way
without disconnecting.
Setting Jumpers A-5
A.5
Set Jumpers
There are three jumpers on the motherboard, which you can
now access. Do not change the Timer Disable jumper or any of
the switches. Correct positions are given in Figure A–4.
Figure A–4 Setting Jumpers on the Motherboard
SW3
SW2
SW1
1
ON
1
ON
1
ON
Halt/Reset Select
Remote Console
Management Jumper
1
1
For OpenVMS
& Tru64 UNIX
Timer Disable Jumper
1
1
For Windows NT
PK0246e
A-6 DS10 Console Reference
•
The Halt/Reset Select jumper affects the operation of the control panel Halt
button. You may be changing this jumper if you are switching to or from
the Windows NT operating system.
•
The RMC jumper enables or disables the remote management console.
•
Do not change the setting of the Timer jumper or any of the switches.
Table A-1 Jumpers and Factory Default Positions
Default position
Jumper
OpenVMS, Tru64 UNIX:
Set for Halt
Windows NT: Set for Reset.
Pins 1-2
RMC
Set for Enable RMC
Pins 2-3
Timer
Set for Enable Timer
Hang jumper loose from pin
1; do not jumper to pin 2.
Halt/Reset
Select
Pins 2-3
To change the jumper on the Halt/Reset Select or RMC jumpers, wearing an
anti-static strap, move the pin to the position described in Table A-1.
Setting Jumpers A-7
A.6
Restore Power
Close up the system and restore power.
1. Replace the floppy drive enclosure (see Section A.4). Check that the cables
are clear and not pinched.
2. Replace the system cover, sliding it forward (see Section A.3). Secure with
the handle and lock on the bulkhead.
3. Plug the AC power cord back into the system or wall outlet, whichever you
disconnected (see Section A-2).
4. Push the On button on the control panel and power up.
A-8 DS10 Console Reference
Index
A
Advanced CMOS setup screen,
AlphaBIOS, 3-30
Alphabios command, SRM, 2-3, 2-38
AlphaBIOS console, 1-5
boot screen, 1-20, 3-2
checking PCI parity, 3-31
displaying system configuration, 36
enabling and disabling settings for
memory test, 3-31
finding help, 3-4
first-level help screen, 3-4
key conventions, 3-4
running in serial mode, 3-46
second-level help screen, 3-5
setting date and time, 3-29
setting keyboard language, 3-29
setting password, 3-31
setup screen, 3-3
starting, 3-2
switching from SRM, 2-37
switching to SRM, 3-31, 3-42
auto_action environment variable,
SRM, 1-5, 2-38, 2-40
Auxiliary power supply,
RMC, 4-1
B
Baud rate, setting for COM* ports, 243
boot command, SRM, 1-6, 1-7, 1-9, 111, 1-12, 1-13, 1-17, 1-19, 2-3, 2-17
passing information to command, 241
using in secure mode, 2-25
Boot screen, AlphaBIOS, 1-20, 3-2
boot_file environment variable, SRM,
1-7, 1-9, 1-13, 1-15, 1-17, 2-25
boot_flags environment variable,
SRM, 2-25
boot_osflags environment variable,
SRM, 1-7, 1-9, 1-13, 1-15, 1-17, 238, 2-41
OpenVMS, 2-41, 2-42
Tru64 UNIX, 2-41
boot_reset environment variable,
SRM, 1-13
bootdef_dev environment variable,
SRM, 1-7, 1-9, 1-13, 1-15, 1-17, 225, 2-38
Booting
OpenVMS, 1-12
from cluster disk, 1-14
from local disk, 1-12
from remote disk, 1-16
passing information to command, 241
Tru64 UNIX, 1-6
from local disk, 1-6
from remote disk, 1-8
Windows NT, 1-20
C
clear alert command (RMC), 4-23
clear envar command, SRM, 2-3
clear password command, SRM, 2-3,
2-26
clear port command (RMC), 4-23
CMOS setup screen, AlphaBIOS, 328, 3-30
COM* ports, setting baud rate, 2-43
com*_baud environment variable,
SRM, 2-38, 2-43
COM1 environment variables, 4-7
Index-1
Command conventions, RMC, 4-22
Command syntax, SRM console, 2-5
Configuring parameters, AlphaBIOS
console, 3-28
Console
AlphaBIOS, 1-5
specifying, 3-31
SRM, 1-5
switching from AlphaBIOS to
SRM, 3-42
switching from SRM to
AlphaBIOS, 2-37
Console commands, SRM, 2-3
Console environment variable, SRM,
2-31, 2-32, 2-38, 2-44
Console terminal
specifying type, 2-44
continue command, SRM, 2-3
using in secure mode, 2-25
cpu_enabled environment variable,
SRM, 2-38
crash command, SRM, 2-3, 2-30
Crash dump, 2-30
D
Date, setting in AlphaBIOS console,
3-29
deposit command, SRM, 2-3, 2-33
Depositing data, 2-33
Device naming conventions, SRM, 211
Dial-in configuration, 4-12
Dialing in, 4-17
Dial-out alerts, 4-14
disable alert command (RMC), 4-23
disable remote command (RMC), 4-24
display command, LFU, 1-41
Display system configuration screen,
AlphaBIOS console, 3-6
Displaying system configuration, 2-8
AlphaBIOS console, 3-6
Displaying the value or setting of an
environment variable, 2-32
Index-2
E
edit command, SRM, 2-3, 2-33
enable alert command (RMC), 4-24
enable remote command (RMC), 4-25
Environment variables, SRM, 2-31
auto_action, 1-5
boot_file, 1-7, 1-9, 1-13, 1-15, 1-17,
2-25
boot_flags, 2-25
boot_osflags, 1-7, 1-9, 1-13, 1-15,
1-17
boot_reset, 1-13
bootdef_dev, 1-7, 1-9, 1-13, 1-15,
1-17, 2-25
displaying the value or setting, 2-32
modifying, 2-31
os_type, 1-5
password, 2-26
setting, 2-31
summary, 2-38
Escape sequence (RMC), 4-6
Ethernet, specifying controller type, 245
ew*0_mode environment variable,
SRM, 2-38, 2-45
ew*0_protocols environment variable,
SRM, 2-38, 2-45
examine command, SRM, 2-3, 2-33
Examing data, 2-33
exit command, LFU, 1-27, 1-31, 1-37,
1-40, 1-41
F
Finding help
AlphaBIOS console, 3-4
SRM console, 2-36
Firmware
updating, 1-27
updating from AlphaBIOS, 3-19
updating from CD-ROM, 1-28
updating from floppy disk, 1-32, 134
updating from network device, 1-38
updating from SRM, 2-28
updating, AlphaBIOS selection, 126
updating, SRM command, 1-26
Formatting hard disk, AlphaBIOS, 321, 3-24, 3-26
OpenVMS, 1-18
Tru64 UNIX, 1-10
Windows NT, 1-22
Installing Windows NT, 3-32
Integrated peripherals screen,
AlphaBIOS, 3-18
IOD, 1-5
G
Graphics monitor, specifying as
console terminal, SRM, 2-44
H
halt command, SRM, 2-3, 2-28
halt in command (RMC), 4-26
Halt, remote, 4-11
hangup command (RMC), 4-13, 4-17,
4-27
Hard disk configuration screen,
AlphaBIOS, 3-10
Hard disk setup screen, AlphaBIOS,
3-21
Hard disk, AlphaBIOS
creating and deleting partitions, 324
error conditions, 1-44
formatting a FAT partition, 3-26
setting up, 3-21
Help
AlphaBIOS console, 3-4
AlphaBIOS first-level help screen,
3-4
AlphaBIOS second-level help
screen, 3-5
help command, LFU, 1-41, 1-42
help command, SRM, 2-3, 2-36
help or ? commands (RMC), 4-27
I
initialize command, SRM, 2-3, 2-15,
2-35
Initializing the system, 2-35
Installing
K
kbd_hardware_type environment
variable, SRM, 2-31, 2-32, 2-38, 246
Key conventions
AlphaBIOS console, 3-4
Key mapping, AlphaBIOS in serial
mode, 3-46
Keyboard
setting language, AlphaBIOS, 3-29
specifying hardware type, SRM, 246
specifying layout, SRM, 2-46
L
language environment variable, SRM,
2-31, 2-32, 2-38, 2-46
LFU
starting, 1-26, 1-27
starting the utility, 1-26
typical update procedure, 1-27
updating firmware from CD-ROM,
1-28
updating firmware from floppy
disk, 1-32, 1-34
updating firmware from network
device, 1-38
lfu command, LFU, 1-35, 1-37, 1-41,
1-42
lfu command, SRM, 1-27, 2-3, 2-28
LFU commands
display, 1-41
exit, 1-27, 1-31, 1-37, 1-40, 1-41
help, 1-41, 1-42
lfu, 1-35, 1-37, 1-41, 1-42
Index-3
list, 1-27, 1-31, 1-35, 1-37, 1-39, 140, 1-41, 1-42
readme, 1-41, 1-42
summary, 1-41
update, 1-27, 1-31, 1-41, 1-43
verify, 1-41, 1-43
list command, LFU, 1-27, 1-31, 1-35,
1-39, 1-41, 1-42
Loadable Firmware Update utility. See
LFU
login command, SRM, 2-3, 2-26
using in secure mode, 2-25
M
Maintenance programs, AlphaBIOS,
3-44
Memory configuration screen,
AlphaBIOS, 3-17
Memory test
enabling and disabling settings in
AlphaBIOS, 3-31
Modifying an environment variable,
SRM, 2-31
more command, SRM, 2-4, 2-34
specifying as default operating
system, 2-47
Operating system
booting OpenVMS, 1-12
from cluster disk, 1-14
from local disk, 1-12
from remote disk, 1-16
booting Tru64 UNIX, 1-6
from local disk, 1-6
from remote disk, 1-8
booting Windows NT, 1-20
installing Tru64 UNIX, 1-10
installing OpenVMS, 1-18
installing Windows NT, 1-22, 3-32
specifying default, 2-47
Operating system selection setup
screen, AlphaBIOS, 3-38
Operating system selection, defined,
3-35
Operating system selections screen,
AlphaBIOS, 3-34
os_type environment variable, SRM,
1-5, 1-21, 2-32, 2-47, 3-31
P
N
Naming conventions, SRM, 2-11
Network protocols, enabling for
booting and other functions, SRM,
2-45
O
ocp_text environment variable, SRM,
2-31, 2-32, 2-39
OpenVMS
booting, 1-12
from cluster disk, 1-14
from local disk, 1-12
from remote disk, 1-16
console for, 2-1
installing, 1-18
Index-4
Pagers, 4-15
Parameters, configuring in
AlphaBIOS console, 3-28
password environment variable, SRM,
2-26
Password, setting in AlphaBIOS
console, 3-31
PCI
enabling and disabling parity
checking on bus, SRM, 2-47, 248
finding device information,
AlphaBIOS, 3-14
parity checking in AlphaBIOS, 3-31
PCI card cage
slot numbers, 2-12
PCI configuration screen, AlphaBIOS,
3-12
PCI options
slot numbers, 2-12
pci_parity environment variable,
SRM, 2-39, 2-47, 2-48
pk*0_fast environment variable, SRM,
2-39, 2-48
pk*0_host_id environment variable,
SRM, 2-39, 2-49
pk*0_soft_term environment variable,
SRM, 2-39, 2-49
power off command (RMC), 4-27
power on command (RMC), 4-28
Power-on/off, from RMC, 4-9
Power-up, specifying console action,
SRM, 2-40
prcache command, SRM, 2-4, 2-18
Primary operating system,
AlphaBIOS, 3-36
Q
quit command (RMC), 4-6, 4-28
R
Reading a file, 2-34
readme command, LFU, 1-41, 1-42
Remote console monitor. See RMC
Remote dial-in, 4-17
Remote power-on/off, 4-9
reset command (RMC), 4-16, 4-29
Reset, from RMC, 4-11
Reset, specifying console action,
SRM, 2-40
RMC
accessing, 4-5
auxiliary power supply, 4-1
clear alert command, 4-23
clear port command, 4-23
command conventions, 4-22
commands, 4-21
configuring call-out, 4-12
dial-out alerts, 4-14
disable alert command, 4-23
disable remote command, 4-24
enable alert command, 4-24
enable remote command, 4-25
entering, 4-6
escape sequence, 4-6
exiting, 4-6
halt in command, 4-26
hangup command, 4-13, 4-17, 4-27
help or ? commands, 4-27
power off command, 4-27
power on command, 4-28
quit command, 4-6, 4-28
remote halt, 4-11
remote power-on/off, 4-11
remote reset, 4-11
reset command, 4-29
resetting to factory defaults, 4-18
send alert command, 4-29
set alert command, 4-30
set dial command, 4-32
set escape command, 4-33
set init command, 4-34
set logout command, 4-35
set password command, 4-35
set user command, 4-36
status command, 4-7, 4-36
terminal setup, 4-3
troubleshooting, 4-19
RMC mode, 4-4
Running maintenance programs,
AlphaBIOS, 3-44
Running utility programs, 3-44
S
SCSI
enabling and disabling terminators,
SRM, 2-46
enabling Fast SCSI, SRM, 2-45
setting controller host bus node ID,
SRM, 2-46
SCSI configuration screen,
AlphaBIOS, 3-15
send alert command (RMC), 4-32
Index-5
Serial terminal, specifying as console
terminal, SRM, 2-40
set alert command (RMC), 4-15, 4-18,
4-33
set dial command (RMC), 4-18, 4-34
Set dial command (RMC), 4-15
set envar command, SRM, 2-4, 2-28,
2-29
set escape command (RMC), 4-35
set host command, SRM, 2-4
set init command (RMC), 4-36
Set init command (RMC), 4-15
set logout command (RMC), 4-37
set password command (RMC), 4-15,
4-37
set password command, SRM, 2-4, 221
set secure command, SRM, 2-4, 2-22
set user command (RMC), 4-38
Setting an environment variable, 2-28
Setting up the hard disk, AlphaBIOS,
3-21
Setup screen, AlphaBIOS, 3-3
show config command, SRM, 2-4, 2-8
show device command, SRM, 1-6, 17, 1-9, 1-12, 1-13, 1-15, 1-17, 2-4,
2-10
show envar command, SRM, 1-12, 24, 2-28, 2-29
show memory command, SRM, 2-4,
2-12
show pal command, SRM, 2-4, 2-12
show power command, SRM, 2-4, 213
show version command, SRM, 2-4, 214
Special characters, SRM console, 2-6
SRM console, 1-5, 2-1–2-47
command syntax, 2-5
device naming conventions, 2-11
invoking, 2-2
special characters, 2-6
summary of commands, 2-3
Index-6
summary of environment variables,
2-35
switching from AlphaBIOS, 3-31,
3-42
switching to AlphaBIOS, 2-34
SRM console commands
alphabios, 2-3, 2-35
boot, 1-7, 1-9, 1-11, 1-13, 1-17, 119, 2-3, 2-18
using in secure mode, 2-22
clear envar, 2-3
clear password, 2-3, 2-24
continue, 2-3
using in secure mode, 2-22
crash, 2-3, 2-27
deposit, 2-3, 2-30
edit, 2-3, 2-30
examine, 2-3, 2-30
halt, 2-3, 2-25
help, 2-3, 2-33
initialize, 2-3, 2-15, 2-32
lfu, 1-27, 2-3, 2-25
login, 2-3, 2-23
using in secure mode, 2-22
more, 2-4, 2-31
prcache, 2-4, 2-19
set envar, 2-4, 2-28, 2-29
set host, 2-4
set password, 2-4, 2-21
set secure, 2-4, 2-22
show config, 2-4, 2-8
show device, 1-7, 1-9, 1-13, 1-15,
1-17, 2-4, 2-10
show envar, 2-4, 2-28, 2-29
show memory, 2-4, 2-12
show pal, 2-4, 2-12
show power, 2-4, 2-13
show version, 2-4, 2-14
start
using in secure mode, 2-22
stop, 2-4, 2-25
summary of commands, 2-3
test, 2-4, 2-20
SRM console environment variables
auto_action, 2-35, 2-37
boot_osflags, 2-35, 2-38, 2-39
boot_osflags, DIGITAL UNIX, 238
boot_osflags, OpenVMS, 2-38
bootdef_dev, 2-35
com*_baud, 2-35, 2-40
commands for displaying the value
or setting, 2-28
commands for modifying, 2-28
commands for setting, 2-28
commands for using, 2-28
console, 2-35, 2-40
cpu_enabled, 2-35, 2-41
ew*0_mode, 2-35, 2-41
ew*0_protocols, 2-35, 2-41
kbd_hardware_type, 2-35, 2-42
language, 2-35, 2-43
ocp_text, 2-36
os_type, 1-21, 2-44, 3-31
pci_parity, 2-36, 2-44, 2-45
pk*0_fast, 2-36, 2-45
pk*0_host_id, 2-36, 2-46
pk*0_soft_term, 2-36, 2-46
tt_allow_login, 2-36, 2-47
SRM firmware
enabling and disabling login to, 247
Standard CMOS setup screen,
AlphaBIOS, 3-28
start command, SRM
using in secure mode, 2-22
Starting AlphaBIOS, 3-2
status command (RMC), 4-8, 4-38
stop command, SRM, 2-4, 2-25
Syntax
SRM console commands, 2-5
System board configuration screen,
AlphaBIOS, 3-8
System configuration
displaying in AlphaBIOS console,
3-6
displaying in SRM console, 2-8
System crash dump, 2-27
System failure, specifying console
action, SRM, 2-37
T
Terminal setup (RMC), 4-3
test command, SRM, 2-4, 2-19
Testing the system (all operating
systems), 2-19
Time, setting in AlphaBIOS console,
3-29
Troubleshooting
RMC, 4-19
Tru64 UNIX
booting, 1-6
from local disk, 1-6
from remote disk, 1-8
console for, 2-1
installing, 1-10
specifying as default operating
system, 2-47
tt_allow_login environment variable,
SRM, 2-39, 2-50
U
update command, LFU, 1-27, 1-31, 137, 1-40, 1-41, 1-43
Updating firmware
AlphaBIOS console, 3-19
from AlphaBIOS console, 1-26
from SRM console, 1-26
SRM console, 2-28
Utility programs, 3-44
running from serial terminal, 3-46
V
verify command, LFU, 1-41, 1-43
Version selection, Windows NT, 3-34
W
Windows NT
auto start, 3-38
booting, 1-20
Index-7
designating primary operating
system, 3-36
installing, 1-22, 3-32
selecting version, 3-34
Index-8
specifying as default operating
system, 2-47
starting automatically, 3-29, 3-38
">
/
Pakua
Kikumbusho tu cha kirafiki. Unaweza kuona hati hapa hapa. Lakini muhimu zaidi, AI yetu tayari imesoma. Inaweza kuelezea mambo magumu kwa maneno rahisi, kujibu maswali yako katika lugha yoyote, na kukusaidia kuvinjari haraka hata hati ndefu au ngumu zaidi.
Tangazo