OWNER S MANUAL Inverter Split-type Room Air Conditioner


Add to my manuals
15 Pages

advertisement

OWNER S MANUAL Inverter Split-type Room Air Conditioner | Manualzz

OWNER S MANUAL

Inverter Split-type Room Air Conditioner

Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.

Downloaded from AC-Manual.com Manuals

SOCIABLE REMARK

The follow contents apply only the countries of Europe.

DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.

It is prohibited to dispose of this appliance in domestic household waste.

For disposal, there are several possibilities:

A) The municipality has established collection systems, where electronic waste can be disposed of at least free of charge to the user.

B) When buying a new product, the retailer will take back the old product at least free of charge.

C) The manufacture will take back the old appliance for disposal at least free of charge to the user.

D) As old products contain valuable resources, they can be sold to scrap metal dealers.

Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground-water and find their way into the food chain.

Downloaded from AC-Manual.com Manuals

CONTENTS

SAFETY PRECAUTIONS .......................................................................................

1

PARTS NAMES .....................................................................................................

3

OPERATING TEMPERATURE ..............................................................................

4

MANUAL OPERATION .........................................................................................

4

ADJUSTING AIR FLOW DIRECTION.....................................................................

5

HOW THE AIR CONDITIONER WORKS................................................................

6

OPTIMAL OPERATION ..........................................................................................

6

MAINTENANCE.......................................................................................................

7

OPERATION TIPS .................................................................................................

9

TROUBLESHOOTING TIPS...................................................................................

11

Read This Manual

Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner.

You'll find many answers to common problems in the chart of troubleshooting tips. If you review the chart of Troubleshooting Tips first, you may not need to call for service.

!

CAUTION

Contact an authorised service technician for repair or maintenance of this unit.

Contact the installer for installation of this unit.

The air conditioner is not intended for use by young children or invalids without supervision.

Young children should be supervised to ensure that they do not play with the air conditioner.

If the power cord is to be replaced, replacement work shall be performed by authorised personnel only.

Installation work must be performed in accordance with the national wiring standards by authorised personnel only.

Downloaded from AC-Manual.com Manuals

SAFETY PRECAUTIONS

To prevent injury to the user or other people and property damage, the following instructions must be followed.

Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications.

!

WARNING

This symbol indicates the possibility of death or serious injury.

!

CAUTION

This symbol indicates the possibility of injury or damage to property.

Meanings of symbols used in this manual are as shown below.

Never do this.

!

Always do this.

!

Connect with the power properly.

!

WARNING

Do not operate or stop the unit by inserting or pulling out the power plug.

It may cause electric shock or fire due to heat generation.

Do not damage or use an unspecified power cord.

!

!

Otherwise, it may cause electric shock or fire due to excess heat generation.

Do not modify power cord length or share the outlet with other appliances

It may cause electric shock or fire due to heat generation.

!

Always ensure effective earthing.

No earthing may cause electric shock.

Disconnect the power if strange sounds, smell, or smoke comes from it.

It may cause fire and electric shock.

Use the correctly rated breaker or fuse.

Do not operate with wet hands or in damp environment.

It may cause electric shock.

Do not allow water to run into electric parts.

It may cause failure of machine or electric shock.

Do not use the socket if it is loose or damaged.

It may cause fire and electric shock.

Do not use the power cord close to heating appliances.

!

It may cause electric shock or fire.

Do not direct airflow at room occupants only.

This could damage your health.

Always install circuit breaker and a dedicated power circuit.

No installation may cause fire and electric shock.

Do not open the unit during operation.

It may cause electric shock.

Do not use the power cord near flammable gas or combustibles, such as gasoline, benzene, thinner, etc.

It may cause an explosion or fire.

There is risk of fire or electric shock.

It may cause fire and electric shock.

!

Ventilate room before operating air conditioner if there is a gas leakage from another appliance.

It may cause explosion, fire and, burns.

Do not disassemble or modify unit.

It may cause failure and electric shock.

1

Downloaded from AC-Manual.com Manuals

When the air filter is to be removed, do not touch the metal parts of the unit.

It may cause an injury.

!

CAUTION

Turn the main power off when cleaning or maintaining the product.

There is risk of electric shock.

!

Ventilate the room well when used together with a stove, etc.

An oxygen shortage may occur.

!

When the unit is to be cleaned, switch off, and turn off the circuit breaker.

Do not clean unit when power is on as it may cause fire and electric shock, it may cause an injury.

!

Stop operation and close the window in storm or hurricane.

Operation with windows opened may cause wetting of indoor and soaking of household furniture.

Do not place obstacles around air-inlets or inside of air-outlet.

It may cause failure of appliance or accident.

!

Do not put a pet or house plant where it will be exposed to direct air flow.

This could injure the pet or plant.

!

Hold the plug by the head of the power plug when taking it out.

Failue to do so may cause electric shock and damage.

Ensure that the installation bracket of the outdoor appliance is not damaged due to prolonged exposure.

If bracket is damaged, there is concern of damage due to falling of unit.

!

Do not use for special purposes.

Do not use this air conditioner to preserve precision devices, food, pets, plants, and art objects.

It may cause deterioration of quality, etc.

Turn off the main power unit for a long time.

It may cause failure of product or fire.

!

Always insert the filters securely. Clean filter once every two weeks.

Operation without filters may cause failure.

Do not use strong detergent such as wax or thinner. Use a soft cloth for cleaning.

Appearance may be deteriorated due to change of product color or scratching of its surface.

Do not place heavy object on the power cord and take care so that the cord is not compressed.

There is danger of fire or electric shock.

!

Use caution when unpacking and installing. Sharp edges could cause injury.

Do not drink water drained from air conditioner.

It contains contaminants and could make you sick.

!

If water enters the unit, turn the unit off at the power outlet and switch off the circuit breaker. Isolate supply by taking the power-plug out and contact a qualified service technician.

2

Downloaded from AC-Manual.com Manuals

PARTS NAMES

INDOOR UNIT

3

Air inlet

2

4

5

Air outlet

6

OUTDOOR UNIT

9

Air inlet

Air outlet

1

7

8

10

DISPLAY PANEL

NOTE:

The display panel on the indoor unit would look like one of following:

Infrared signal receptor

TIMER RUN

DEF.

AUTO

12

11

INDOOR UNIT

1

Front panel frame

2

Front panel

3

4

5

6

7

Air filter

Horizontal air flow grille

Vertical air flow louver

Room temperature sensor

Display panel

8

9

10

11

Infrared signal receiver

Remote controller

Drain hose, refrigerant connecting pipe

Connective cable

12

Stop valve

DISPLAY PANEL

OPERATION/RUN indicator:

The indicator flashes once every second after power is on and illuminates when the air conditioner is in operation.

TIMER indicator:

The indicator illuminates when TIMER is set ON.

PRE-DEF./DEF. Indicator

(For cooling& heating model only)

:

This indicator illuminates when the air conditioner starts defrosting automatically or when the Anticold air feature is activated in heating operation.

AUTO indicator:

This indicator flashes when the air conditioner is in AUTO operation.

Note:

All the pictures in this manual are for explanation purpose only. They may be slightly different from the air conditioner you purchased. The actual shape shall prevail.

Infrared signal receptor

OPERATION AUTO

TIMER

PRE-DEF

3

Downloaded from AC-Manual.com Manuals

OPERATING TEMPERATURE

Mode

Temperature

Room temperature

Cooling operation

>17 C

Heating operation

<30 C

Drying operation

>10 C

Outdoor temperature

0 C

~

50 C

( -15 C

~

50 C:For the models with low temperature cooling system)

-15 C

~

34 C

0 C

~

50 C

CAUTION:

1. If air conditioner is used outside of the above conditions, certain safety protection features may come into operation and cause the unit to function abnormally.

2. Room relative humidity less than 80%. If the air conditioner operates in excess of this figure, the surface of the air conditioner may attract condensation. Please sets the vertical air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.

3. Optimum performance will be achieved within these operating temperature.

MANUAL OPERATION

Manul operation can be used temporarily in case you can not find the remote controller or its batteries are exhausted.

Manual control button

AUTO/COOL

Manual control button

AUTO/COOL

NOTE: The unit must be turned off before operating the manual control button. If the unit is operational, continue pressing the manual control button until the unit is off.

1

2

3

Open and lift the front panel up to an angle until it remains fixed with a clicking sound.

One press of the manual control button will lead to the forced AUTO operation. If press the button twice within five seconds, the unit will operate under forced COOL operation.

Close the panel firmly to its original position.

CAUTION:

This button is used for testing purposes only. You had better not choose it.

To restore the remote controller operation, use the remote controller directly.

4

Downloaded from AC-Manual.com Manuals

ADJUSTING AIR FLOW DIRECTION

Lever

Adjust the air flow direction properly otherwise, it might cause discomfort or cause uneven room temperatures.

Adjust the horizontal louver using the remote controller.

Adjust the vertical louver manually.

To set the vertical air flow(Up--Down) direction

Perform this function while the unit is in operation.

Use the remote controller to adjust the air flow direction. The horizontal louver can be moved at

,, and down automatically. Please refer to the

REMOTE CONTROLLER OPERATION MANUAL

,,

for details.

To set the horizontal air flow direction (left - right)

Adjust the vertical louver manually using the lever on the left or right side of the vertical louver arm

(Depending on model). Take care not to catch fingers on the fan, horizontal louver or to damage vertical louvers. When the air conditioner is in operational and the horizontal louver is in a specific position, move the lever at left (or right, depending on model) end of the air outlet to the desired position.

!

CAUTION

The DIRECTION/SWING button will be disabled when the air conditioner is not in operation(including when the TIMER

ON is set).

Do not operate the air conditioner for long periods with air flow direction set downward in cooling or dry mode.

the

Otherwise, condensation may occur on the surface of the horizontal louver causing moisture to drop on to the floor or on furnishings.

Do not move the horizontal louver manually. Always use the

DIRECTION/SWINGbutton. If you move this louver manually, it may malfunction during operation. If the louver malfunctions, stop the air conditioner once and restart it.

When the air conditioner is started immediately after it was stopped, the horizontal louver might not move for approximately 10 seconds.

Open angle of the horizontal louver should not be set too small, as COOLING or HEATING performance may be impaired due to too restricted air flow area.

Do not operate unit with horizontal louver in closed position.

When the air conditioner is connected to power (initial power), the horizontal louver may generate a sound for 10 seconds, this is a normal operation.

5

Downloaded from AC-Manual.com Manuals

HOW THE AIR CONDITIONER WORKS

ECONOMIC (SLEEP) operation

Set

Temperature

1

1

1 hour

1 hour

Cooling

ECONOMIC (SLEEP) operation

Set

Temperature

1

1

1 hour

1 hour

Heating

AUTOMATIC OPERATION

When you set the air conditioner in AUTO mode, it will automatically select cooling, heating(cooling/heating models only), or fan only operation depending on what temperature you have selected and the room temperature.

The air conditioner will control room temperature automatically round the temperature point set by you.

If the AUTO mode is uncomfortable, you can select desired conditions manually.

ECONOMIC(SLEEP) OPERATION

When you push ECONO (SLEEP) button on remote controller during cooling, heating(cooling only type without), or AUTO operation , the air conditioner will automatically increase (cooling) or decrease (heating) 1 per hour.

The set temperature will be steady 2 hours later. The fan speed will be automatically controlled. This feature can maintain the most comfortable temperature and save more energy for you.

DRYING OPERATION

The fan speed will be automatically controlled under dry operation.

During the dry operation, if the room temperature is lower

O than 10 C, the compressor stops operation and restarts

O until the room temperature is above 12 C.

OPTIMAL OPERATION

To achieve optimal performance, please note the following:

Adjust the air flow direction correctly so that it is not directed on people.

Adjust the temperature to achieve the highest comfort level. Do not adjust the unit to excessive temperature levels.

Close doors and windows on COOL or HEAT modes, or performance may be reduced.

Use TIMER ON button on the remote controller to select a time you want to start your air conditioner.

Do not put any object near air inlet or air outlet, as the efficiency of the air conditioner may be reduced and the air conditioner may stop running.

Clean the air filter periodically, otherwise cooling or heating performance may be reduced.

Do not operate unit with horizontal louvre in closed position.

6

Downloaded from AC-Manual.com Manuals

MAINTENANCE

Filter Handle

WARNING

It is necessary to stop the air conditioner and disconnect the power supply before cleaning.

Cleaning the indoor unit and remote controller

CAUTIONS

Use a dry cloth to wipe the indoor unit and remote controller.

A cloth dampened with cold water may be used on the indoor unit if it is very dirty.

The front panel of the indoor unit can be removed and cleaned with water. Then wipe it with a dry cloth.

Do not use a chemically treated cloth or duster to clean the unit.

Do not use benzine, thinner, polishing powder, or similar solvents for cleaning. These may cause the plastic surface to crack or deform.

Cleaning the air filter

A clogged air filter reduces the cooling efficiency of this unit. Please clean the filter once every 2 weeks.

1. Lift the indoor unit panel up to an angle until it stops with a clicking sound.

2. Take hold of the handle of the air filter and lift it up slightly to take it out from the filter holder, then pull it downwards.

3. Remove the AIR FILTER from the indoor unit.

Clean the AIR FILTER once two weeks.

Clean the AIR FILTER with a vacuum cleaner or water, then dry it up in cool place.

Downloaded from AC-Manual.com Manuals

7

MAINTENANCE

Air freshening filter

Air freshening filter

4. Remove the air freshening filter from its support frame

(The installation and removing method of the air freshening filter is different depending on the models, see the pictures marked and on the left.

Clean the air freshening filter at least once a month, and replace it every 4-5 months.

Clean it with vacuum cleaner, then dry it in cool place.

5. Install the air freshening filter back into position.

6. Insert the upper portion of air filter back into the unit taking care that the left and right edges line up correctly and place filter into position.

Maintenance

If you plan to idle the unit for a long time, perform the following:

(1) Operate the fan for about half a day to dry the inside of the unit.

(2) Stop the air conditioner and disconnect power.

Remove the batteries from the remote controller.

(3) The outdoor unit requires periodic maintenance and cleaning. Do not attempt to do this yourself.

Contact your dealer or servicer.

Checks before operation

Check that the wiring is not broken off or disconnected.

Check that the air filter is installed.

Check if the air outlet or inlet is blocked after the air conditioner has not been used for a long time.

CAUTIONS

Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges.

Do not use water to clean inside the air conditioner.

Exposure to water can destroy the insulation, leading to possible electric shock.

When cleaning the unit, first make sure that the power and circuit breaker are turned off.

8

Downloaded from AC-Manual.com Manuals

OPERATION TIPS

The following events may occur during normal operation.

1.

Protection of the air conditioner.

Compressor protection

The compressor can't restart for 3 minutes after it stops.

Anti-cold air (Cooling and heating models only)

The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached.

A) When heating has just starting.

B) Defrosting.

C) Low temperature heating.

The indoor or outdoor fan stop running when defrosting (Cooling and heating models only).

Defrosting (Cooling and heating models only )

Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low and humidity is high resulting in lower heating efficiency of the air conditioner.

During this condition air conditioner will stop heating operation and start defrosting automatically.

The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and the amount of frost buildup on the outdoor unit.

2.

A white mist coming out from the indoor unit

A white mist may generate due to a large temperature difference between air inlet and air outlet on COOL mode in an indoor environment that has a high relative humidity.

A white mist may generate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting.

3.

Low noise of the air conditioner

You may hear a low hissing sound when the compressor is running or has just stopped running.

This sound is the sound of the refrigerant flowing or coming to a stop.

You can also hear a low "squeak" sound when the compressor is running or has just stopped running. This is caused by heat expansion and cold contraction of the plastic parts in the unit when the temperature is changing.

A noise may be heard due to louver restoring to its original position when power is first turned on.

4.

Dust is blown out from the indoor unit.

This is a normal condition when the air conditioner has not been used for a long time or during first use of the unit.

5.

A peculiar smell comes out from the indoor unit.

This is caused by the indoor unit giving off smells permeated or smoke.

from building material, from furniture,

6.

The air conditioner turns to FAN only mode from COOL or HEAT (For cooling and heating models only) mode.

When indoor temperature reaches the temperature setting on air conditioner, the compressor will stop automatically, and the air conditioner turns to FAN only mode. The compressor will start again when the indoor temperature rises on COOL mode or falls on HEAT mode (For cooling and heating models only) to the set point.

9

Downloaded from AC-Manual.com Manuals

7. Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed.

8.

Heating mode (For cooling and heating models only)

The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit during heating operation. When the outdoor temperature falls, heat drawn in by the air conditioner decreases accordingly. At the same time, heat loading of the air conditioner increases due to larger difference between indoor and outdoor temperature. If a comfortable temperature can't be achieved supplementary heating device.

by the air conditioner, we suggest you use a

9.

Auto-restart function

Power failure during operation will stop the unit completely.

For the unit without Auto-restart feature, when the power restores, the OPERATION indicator on the indoor unit starts flashing. To restart the operation, push the ON/OFF button on the remote controller. For the unit with Auto-restart feature, when the power restores, the unit restarts automatically with all the previous settings preserved by the memory function.

10. Lightning or a car wireless telephone operating nearby may cause the unit to malfunction.

Disconnect the unit with power and then re-connect the unit with power again. Push the

ON/OFF button on the remote controller to restart operation.

Downloaded from AC-Manual.com Manuals

10

TROUBLESHOOTING TIPS

Malfunctions and Solutions

Stop the air conditioner immediately if one of the following faults occur. Disconnect the power and contact the nearest customer service center.

OPERATION/RUN indicator or other indicators flash rapidly (5 times every second) and this flash can't be fixed by disconnecting the power, and then connect it in again.

Trouble

Fuse blows frequently or circuit breaker trips frequently.

Other objects or water penetrate the air conditioner.

The remote controller won't work or works abnormally.

Other abnormal situations.

Malfunctions

Unit does not start

Power cut

Cause

Unit may have become unplugged.

What should be done?

Wait for power to be restored.

Check that plug is securely in wall receptacle.

Replace the fuse.

Fuse may have blown.

Battery in Remote controller may have been exhausted.

Replace the battery.

Unit not cooling or heating

(Cooling/ heating models only) room very well while air flowing out from the air

The time you have set with timer is incorrect.

Inappropriate temperature setting.

Air filter is blocked.

Doors or Windows are open.

Air inlet or outlet of indoor or outdoor unit has been blocked.

Wait or cancel timer setting.

Set temperature correctly. For detailed method please refer to

" "

Clean the air filter.

Close the doors or windows.

Clear obstructions away first, then restart the unit.

Compressor 3 minutes protection has been activated.

Wait.

If the trouble has not been corrected, please contact a local dealer or the nearest customer service center. Be sure to inform them of the detailed malfunctions and unit model.

Notes: Do not attempt to repair the unit yourself.

Always consult an authorised service provider.

11

Downloaded from AC-Manual.com Manuals

The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.

CS383-U1

202000190149

20100630

Downloaded from AC-Manual.com Manuals

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

advertisement