Bunn-O-Matic LCC-2 LP Operation Manual

Below you will find brief information for Liquid Coffee Chilled Dispenser LCC-2 LP. The Liquid Coffee Chilled Dispenser delivers two types of coffee plus hot water. The dispenser can be set up for continuous draw (by the cup) for self-serve applications, or portion-control to fill carafes and decanters for wait staff.

PDF
Document
Liquid Coffee Chilled Dispenser LCC-2 LP Installation & Operating Manual | Manualzz

Advertisement

Advertisement

/

Advertisement

Key features

  • Continuous Draw

  • Portion Control

  • Hot Water Dispense

  • Rinse Alarm Feature

  • Programmable Dispense Volume

  • Calibratable Flow Rates

  • Empty Product Warning

Frequently asked questions

Open the dispenser door, select Prime on the Function Selector Switch and Run on the Mode Selector Switch, close the dispenser door, place a container under the dispense tip, activate the appropriate dispenser until concentrate flows from the dispense nozzle, priming may take 5 to 10 seconds, open the dispenser door, select Normal on the Function Selector Switch.

Disconnect the dispenser from the power source, shut off and disconnect the incoming water supply, remove the right side access panel, pull out drain tube to empty into a sink or a container with a minimum of 200 ounce capacity, make sure drain clamp is closed, then remove drain plug, direct tube into sink or container and open drain clamp, continue draining tank until ALL of the water is out, be careful when draining the water as it may be very hot, close drain clamp, insert drain plug, place drain tube back into machine, and replace the right side access panel.

Open the door of the dispenser and select PROGRAM on the Mode Selector Switch, depress and hold the MENU switch for approximately 10 sec, the unit will display “C1 run” when it has entered the Calibration Mode, select PRIME on the Function Selector Switch, place a container under the left Dispense Tip and depress the Regular dispense switch until a steady stream of concentrate comes out the tip (5 to 10 seconds), stop priming and allow the tip to stop dripping, discard the concentrate collected, place a 50 ml graduated cylinder under the Left Dispense Tip, press & Hold the Regular dispense switch, the dispenser will display a 20 second count down timer and then shut the pump OFF automatically, release the dispense switch, keep the graduated cylinder under dispense tip until all the concentrate has dripped out, measure the volume of concentrate collected in the graduated cylinder, if the amount collected is not within the acceptable range, empty the graduated cylinder and repeat STEPS 6 – 9, if the amount collected is still not within range, replace the pump tubing with a new Tube Kit, when satisfied with the volume of concentrate collected, press the MENU switch, the current Calibration volume “C1 XX” will be displayed, use the (-) / (+) keys to adjust number displayed to the amount measured in STEP 9, depress the MENU switch to display the Decaffeinated Concentrate Pump calibration menu “C2 run” and repeat STEPS 3 – 13 above for the right side “Decaf” pump.