advertisement
▼
Scroll to page 2
of
32
Owner’s Operation and Maintenance Manual Supine Bath Tub IH6300 Fixed Height IH6300ADH Adjustable Height AFTER INSTALLATION, PLEASE CALL CUSTOMER SERVICE AT 1-800-668-2337 TO ARRANGE FOR AN IN-SERVICE ON THE TUB DEALER: This manual MUST be given to the user of the tub. USER: BEFORE using this tub, read this manual and save for future reference. For more information regarding Invacare products, parts, and services, please visit www.invacare-ccg.com WARNING DO NOT USE THIS PRODUCT OR ANY AVAILABLE OPTIONAL EQUIPMENT WITHOUT FIRST COMPLETELY READING AND UNDERSTANDING THESE INSTRUCTIONS AND ANY ADDITIONAL INSTRUCTIONAL MATERIAL SUCH AS OWNER’S MANUALS, SERVICE MANUALS OR INSTRUCTION SHEETS SUPPLIED WITH THIS PRODUCT OR OPTIONAL EQUIPMENT. IF YOU ARE UNABLE TO UNDERSTAND THE WARNINGS, CAUTIONS OR INSTRUCTIONS, CONTACT A HEALTHCARE PROFESSIONAL, DEALER OR TECHNICAL PERSONNEL BEFORE ATTEMPTING TO USE THIS EQUIPMENT OTHERWISE, INJURY OR DAMAGE MAY OCCUR. THE INITIAL SET UP OF THIS TUB MUST BE PERFORMED BY A QUALIFIED TECHNICIAN. PROCEDURES OTHER THAN THOSE DESCRIBED IN THIS MANUAL MUST BE PERFORMED BY A QUALIFIED TECHNICIAN. ACCESSORIES WARNING Invacare products are specifically designed and manufactured for use in conjunction with Invacare accessories. Accessories designed by other manufacturers have not been tested by Invacare and are not recommended for use with Invacare products. For further information on this product, please call the following: Customer Service ‐ 1‐800‐668‐2337 Technical Support ‐ 1‐800‐668‐2337 Supine Bath Tub 2 Part No 1096926 TABLE OF CONTENTS TABLE OF CONTENTS SPECIAL NOTES ................................................................................ 5 LABEL LOCATION ............................................................................ 6 TYPICAL PRODUCT PARAMETERS .................................................... 7 FEATURES ........................................................................................ 8 SECTION 1—GENERAL GUIDELINES ................................................... 9 Installation ....................................................................................................................................................9 Electrical .......................................................................................................................................................9 Grounding Instructions.........................................................................................................................9 Plumbing........................................................................................................................................................9 Maintenance and Inspection...................................................................................................................10 Electrical Shock Hazard ......................................................................................................................10 Disinfecting.................................................................................................................................................10 Operation...................................................................................................................................................10 SECTION 2—DISINFECTING THE TUB .............................................. 12 Disinfecting the Tub Using the Closed Loop System.......................................................................12 SECTION 3—OPERATION ................................................................ 13 Overview ....................................................................................................................................................13 Preparing the Tub for Use......................................................................................................................13 Operating the Tub....................................................................................................................................14 Using Water Temperature Setting ..................................................................................................14 Operating Shower/Massage Wand ..................................................................................................15 Filling the Tub .......................................................................................................................................15 Using Hydromassage ...........................................................................................................................15 Adjusting Tub Height - Model IH6300ADH ONLY .........................................................................16 Raising the Supine Tub........................................................................................................................16 Lowering the Supine Tub ...................................................................................................................16 SECTION 4—INSTALLATION ........................................................... 17 Preparing the Work Area.......................................................................................................................17 Securing the Tub.......................................................................................................................................18 Electrical Hook-up....................................................................................................................................19 Electrical Installation ................................................................................................................................21 Plumbing Hook-Up...................................................................................................................................22 Plumbing Installation ................................................................................................................................23 Part No 1096926 3 Supine Bath Tub TABLE OF CONTENTS TABLE OF CONTENTS SECTION 5—MAINTENANCE ........................................................... 25 Parts Information......................................................................................................................................25 Safety Inspection Checklists...................................................................................................................25 Initially.....................................................................................................................................................25 Before Each Use ...................................................................................................................................25 Every 80-150 Baths..............................................................................................................................25 Every Six Months..................................................................................................................................26 Maintenance for IH6300ADH Adjustable Height ONLY Glide Pads ...........................................26 Removing Soap Film and Hard Water Deposits ...............................................................................26 Removing Calcium Deposits, Scale and Lime Build-up ....................................................................26 Heavy Duty Cleaning Procedure ..........................................................................................................27 Calibrating the Disinfectant Flowmeter ..............................................................................................28 Maintenance Record ................................................................................................................................30 SECTION 6—TROUBLESHOOTING .................................................... 31 LIMITED WARRANTY ..................................................................... 32 Supine Bath Tub 4 Part No 1096926 SPECIAL NOTES SPECIAL NOTES Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage. Refer to the table below for definitions of the signal words. SIGNAL WORD MEANING DANGER Danger indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING Warning indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Caution indicates a potentially hazardous situation which, if not avoided, may result in property damage or minor injury or both. NOTICE THE INFORMATION CONTAINED IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. RADIO FREQUENCY INTERFERENCE Most electronic equipment is influenced by Radio Frequency Interference (RFI). CAUTION should be exercised with regard to the use of portable communication equipment in the area around such equipment. If RFI causes erratic behavior, PUSH the Red Power Switch OFF IMMEDIATELY. DO NOT turn the Power Switch ON while transmission is in progress. MAINTENANCE Maintenance MUST be performed ONLY by qualified personnel. Information on maintenance and adjustment of the thermoscopic mixing valve (RADA) is in the RADA Owner’s Manual which is included with this product. Part No 1096926 5 Supine Bath Tub LABEL LOCATION LABEL LOCATION ! WARNING DO NOT install a heater in the tub. Installing a heater will violate safety codes and may result in scalding injuries to the user. P/N 1150694 Rev P/N 1150694 Rev AA %+ ! % 1150694 ! WARNING ! WARNING This dispensing system has been factory tested and calibrated for use with INVACARE Disinfectant. The use of any disinfectant with a dilution ratio or viscosity level different than that of INVACARE Disinfectant will result in an improper mixture of disinfectant and water. This may cause your system to be improperly disinfected - or in some instances, not disinfected at all. If you choose to use a product other than INVACARE Disinfectant, Invacare will not be responsible for the proper calibration or function of your disinfectant system. "#$ % #&$"''() './.0'12).3'1"4.( %#<==9 # #< #% % , ! #% +(.@8&' !/8.( %# &)1'7.00.3+./29:;9 # 5 %8 (.(6(723 (56('72 .72; 8'1 >?0 51 '? 0() #% # ! #* & +##, PAR9992 BEFORE using Supine Tub READ U N D E R S TA N D Owner's Manual proper operation safety procedures. the and the for and 1095611 Disinfectant Cabinet Read and understand ALL information on Invacare disinfectant BEFORE use. Refer to Owner's Manual for proper disinfecting procedures. 1095523 ! WARNING Rev.A(1) - 02/00 BEFORE immersing patient or operating the shower/massage wand, check that the water temperature is between 95˚ and 105˚ fahrenheit (35˚ and 41˚ C) to avoid scalding the patient. 1095524 Rev.A(1) - 02/00 1095523 ! WARNING For disinfecting use ONLY. DO NOT use for showering. Refer to Owner's Manual for proper disinfecting procedures. 1095526 Rev.A(1) - 02/00 1095611 1095524 Rev.A(1) - 02/00 1095526 ! WARNING DO NOT stand in tub. Tub surfaces are slippery when wet. Serious injury may occur. 1097288 Rev.A(1) - 02/00 ! WARNING DO NOT STAND ON TUB FRAME. 1097288 Frame is slippery when wet. Foot injury possible when adjusting tub height. 1095525 Rev.A(1) - 02/00 1095525 ! WARNING ELECTRICAL SHOCK HAZARD. All disassembly and maintenance of the Supine Tub MUST be done by a qualified technician, certified electrician or plumber. Disconnect electrical supply or turn OFF circuit breaker before performing any maintenance to the Supine Tub. 1097132 Rev.A(1) - 02/00 ! DANGER The National Electrical Code requires the use of a ground fault circuit interrupter on all therapeutic pools and tubs (hydro-therapeutic tanks). Failure to follow this requirement could result in serious or fatal injury. 1097132 1095610 Rev.A(1) - 02/00 1095610 NOTE: Model IH6300ADH ONLY CAUTION ! Some state and local plumbing codes require the installation of a “reduced pressure zone” (RPZ) assembly on both the incoming hot and cold supply lines to prevent back flow contamination into the potable water system. Invacare recommends you check local plumbing code requirements to determine if RPZs are required on your tub installation. RPZs are NOT supplied by Invacare and are to be provided by the customer if required. DANGER ELECTRICAL SHOCK HAZARD. For use with hospital grade GFCI receptacle ONLY. Failure to do so may result in an electrical shock and/or serious or fatal injury. DO NOT remove this label. 1097131 Rev.A(1) - 02/00 1097131 P/N 1150759 Rev A 1150759 Supine Bath Tub 6 Part No 1096926 TYPICAL PRODUCT PARAMETERS TYPICAL PRODUCT PARAMETERS IH6300 FIXED HEIGHT IH6300ADH ADJUSTABLE HEIGHT Height Tub Rim 32 inches (813 mm) Raised N/A 41 inches (1041 mm) Lowered N/A 27 inches (686 mm) Overall Tub Height 56 inches (1422 mm) Raised N/A 65 inches (1651 mm) Lowered N/A 51 inches (1295 mm) Tub Exterior 38 inches (965 mm) 38 inches (965 mm) Tub Interior at Shoulder 30 inches (762 mm) 30 inches (762 mm) Tub Interior at Hip 25 inches (635 mm) 25 inches (635 mm) Tub Interior at Foot 22 inches (559 mm) 22 inches (559 mm) Overall Tub Length 94 inches (2388 mm) 94 inches (2388 mm) Tub Interior 69 inches (1753 mm) 69 inches (1753 mm) Frame Base 49 inches (1245 mm) 49 inches (1245 mm) Tub (shipping weight) 725 lbs (329 kg) 725 lbs (329 kg) Tub (empty) 700 lbs (318 kg) 700 lbs (318 kg) Tub w/ 103 gal of water (max water capacity) 1575 lbs (714 kg) 1575 lbs (714 kg) Floor Load Capacity 66 PSI (45 n/cm2) 66 PSI (45 n/cm2) Maximum 103 gal (390 l) 103 gal (390 l) w/ Tub Occupied (average usage) 70-77 gal maximum (265-292 l) 70-77 gal maximum (265-292 l) Water Fill Rate 24 gal per min (91 l/min) 24 gal per min (91 l/min) Water Pressure 65 PSI maximum (448 kPa) 65 PSI maximum (448 kPa) Water Drain Rate 25 gal per min (95 l/min) 25 gal per min (95 l/min) Pump Motor 3/4 HP 3/4 HP Flow Rate 70 gal per min (265 l/min) 70 gal per min (265 l/min) Classification Class I, Type B Class I, Type B Ingress Protection IPX5 IPX5 Power 115 VAC; 50/60 Hz 115 VAC; 50/60 Hz Current Rating 11 amp continuous, maximum 13 amp continuous, maximum Width Length Weight Water Capacity Hydromassage System Electrical Part No 1096926 7 Supine Bath Tub FEATURES FEATURES Model IH6300 Fixed Height Tub CONTROL PANEL Model IH6300ADH Adjustable Height Tub TUB INTERIOR Disinfectant Flow Meter Disinfectant Cabinet Disinfectant On/Off Shower Massage Wand Water Temperature Thermometer Water Temperature Control Valve Disinfectant Wand Shower ON/OFF Tub Fill ON/OFF Tub Controls UP/Down Whirlpool Aerator Whirlpool ON/OFF Tub Fill Spout Overflow Whirlpool Jets Whirlpool Inlet Drain NOTE: Model IH6300ADH Adjustable Height Tub Shown. Supine Bath Tub 8 Part No 1096926 SECTION 1—GENERAL GUIDELINES SECTION 1—GENERAL GUIDELINES WARNING SECTION 1 - GENERAL GUIDELINES contains important information for the safe operation and use of this product. Check all parts for shipping damage before using. In case of damage, DO NOT use the equipment. Contact the ICCG dealer for further instructions. Installation ICCG assumes no responsibility for code infractions or damage to components due to improper installation. Use extreme care during installation. The installation area MUST be able to support the 66 pounds per square inch load capacity of the Supine Tub. After installation and before use ensure all parts are properly and securely installed. Ensure bathroom floor is dry and free of obstructions before transporting or assembling unit. Be certain ALL electrical work is performed by a qualified electrician and is in compliance with local electrical codes. Electrical Grounding Instructions Model IH6300 Supine Tub MUST be direct wired to wall using hot, neutral and ground wires in accordance with the National Electrical Code. External wiring MUST be grounded through a 15 amp breaker and GFCI receptacle. Model IH6300ADH Supine Tub MUST be plugged into a hospital grade GFCI receptacle with a 15 AMP breaker. Plumbing Be certain ALL plumbing work is performed by a qualified plumber. Some state and local plumbing codes require the installation of a “reduced pressure zone” (RPZ) assembly on both the incoming hot and cold supply lines to prevent back flow contamination into the potable water system. Invacare recommends you check local plumbing code requirements to determine if RPZs are required on your tub installation. RPZs are NOT supplied by Invacare and are to be provided by the customer if required. The hot water supply to the tub MUST NOT exceed 110° F (43° C) to protect the user from scalding. Part No 1096926 9 Supine Bath Tub SECTION 1—GENERAL GUIDELINES When operating water pressure exceeds 55 p.s.i., pressure regulators (similar to the ¾‐inch Watts U5) MUST be installed. Maintenance and Inspection If any part of the system is NOT functioning properly, DO NOT use the system. Have the system serviced to correct the problem. The system MUST be maintained on a regular basis to ensure it is functioning properly. Electrical Shock Hazard All disassembly and maintenance of the tub MUST be done by a qualified technician, certified electrician or plumber. Disconnect electrical supply or turn Off circuit breaker before performing any maintenance to the tub. Disinfecting Disinfect the tub after initial set up and ALWAYS disinfect the tub AFTER each use to avoid resident infection and contamination of the tub. DO NOT disinfect the tub when it is occupied otherwise injury may occur. ALWAYS wear gloves, protective apron, and face shield protection when disinfecting or cleaning your tub. ALWAYS handle disinfectants, cleaning compounds, and powdered sanitizers with extreme care. Physical or mechanical damage caused by improper handling or usage of such products will not be the responsibility of ICCG. DO NOT attempt to turn on whirlpool pump during the disinfectant cycle. Doing so could result in skin or eye contact with the disinfectant, which is corrosive. If contact is made, rinse IMMEDIATELY with water. If irritation occurs, consult a physician. ALWAYS read and follow disinfectant label directions carefully. NEVER use abrasive cleaners like scouring powder or liquid cleaners containing pumice stone. The use of these types of cleaners will make the gel‐coat finish of your tub scratched and dull. NEVER use cleaners containing iodine, bromine, Betadine® or methylene blue. The use of these types of cleaners will cause the tub to stain. Never use cleaners containing bleach. Use of these types of cleaners will dry out the rubber seals and gaskets and the tub will not function properly. Operation DANGER Keep hair and body away from suction guard when pump is running. Supine Bath Tub 10 Part No 1096926 SECTION 1—GENERAL GUIDELINES The Supine Tub is specifically designed to be used with a bath lift. ICCG recommends use of the Traverse Lift Model 1200 ONLY. Bath lifts designed by other manufacturers are NOT to be utilized with the Supine Tub. Use of these products is prohibited and will void ICCG’s Supine Tub warranty. Use ONLY Traverse Lift Model 1200 to maintain resident safety and product utility. Refer to the lift owner’s manual for complete life operating and safety instructions. NEVER operate whirlpool without water level above the whirlpool jets. Severe pump damage will result. DO NOT operate this unit without the guard over the (water intake) suction fitting. The guard is a safety device that reduces the potential hazard of hair or body entrapment. To reduce the risk of injury, DO NOT permit children or infirm persons to use this unit unless they are supervised at all times. Recommended length of a bath is 5 to 10 minutes. However, if you become nauseous or dizzy or develop a headache, get out at once and cool down. Get medical attention if symptoms persist. Also, check with a physician before using this unit again. Anyone under a doctorʹs supervision, pregnant, or with poor health, should check with a physician before using this unit. DO NOT use directly after eating or while under the influence of alcohol or drugs. Part No 1096926 11 Supine Bath Tub SECTION 2—DISINFECTING THE TUB SECTION 2—DISINFECTING THE TUB WARNING Disinfect the tub after EACH use to avoid resident infection and contamination of the tub. DO NOT disinfect the tub when it is occupied otherwise injury may occur. Read and understand all information on Invacare brand disinfectant before use. ALWAYS wear rubber gloves, an apron and a face shield when using disinfectant. In case of eye or skin contact, follow procedures on disinfectant container. The disinfectant dispensing system has been factory tested and calibrated for use with Invacare disinfectant. The use of any disinfectant with a dilution ratio (½ oz. per gallon) or viscosity level different than that of Invacare disinfectant will result in an improper mixture of disinfectant and water. This may cause your system to be improperly disinfected - or in some instances, not disinfected at all. If using any disinfectant with a dilution ratio or viscosity level different than that of Invacare disinfectant or if switching from one type of disinfectant to another type, the disinfectant flowmeter MUST be calibrated before performing this procedure. Refer to Calibrating the Disinfectant Flowmeter on page 28. DO NOT use the disinfectant wand for showering. The disinfectant wand is to be used for disinfecting ONLY. CAUTION NEVER use abrasive cleaners like scouring powder or liquid cleaners containing pumice stone. The use of these types of cleaners will make the gel-coat finish of your tub scratched and dull. NEVER use cleaners containing iodine, bromine, Betadine or methylene blue. The use of these types of cleaners will cause the tub to stain. Never use cleaners containing bleach. Use of these types of cleaners will dry out the rubber seals and gaskets and the tub will not function properly. Disinfecting the Tub Using the Closed Loop System NOTE: For this procedure, refer to FIGURE 2.1. NOTE: Ensure that the whirlpool jets and whirlpool inlet fitting are closed before starting this procedure. 1. Clean the entire tub surface to remove visible tissue residue and fluid. 2. Depending on the type of whirlpool jets that are in your tub, close all jets by performing one of the following: • Turn the center of the jet clockwise to a full stop. • Push the center of the jet in. 3. Close the whirlpool inlet by gently pulling the plug in the center of the inlet cover outward until it stops. 4. Open aerator by rotating aerator knob two turns counter‐clockwise. 5. Open disinfectant cabinet on the top of the tub. Whirlpool Jet DETAIL “A” 6. Ensure that disinfectant siphon tube is placed in WHIRLPOOL JET disinfectant container. AND INLET DETAILS 7. Hold the disinfectant wand over the interior of the tub. Push In To 8. Adjust water temperature to 105°F (40°C). Turn Clockwise Close to Close 9. Turn disinfectant On/Off valve to the On position. NOTE: Liquid will begin flowing from the disinfectant wand into the tub. Whirlpool Inlet 10. Turn the adjustment knob on the flow meter until the Plug floating ball rises to a level of 35 cc/min. NOTE: At 35 cc/min., disinfectant is being mixed with water at DETAIL “B” the proper ratio. TUB DETAILS 11. Continue to hold the disinfectant wand over the Adjustment Knob Flow meter interior of the tub. Ball NOTE: When disinfectant has totally filled the interior plumbing, liquid will begin to flow from the disinfectant wand. NOTE: Invacare recommends that you thoroughly scrub all interior surfaces of the tub with disinfectant. The use of a long‐ handled brush will make this operation easier. Disinfectant Cabinet Disinfectant 12. Spray the interior surfaces of the tub, including the Siphon Tube Disinfectant whirlpool jets, overflow fitting and whirlpool inlet On/Off Valve fitting with disinfectant. Scrub all interior surfaces. Disinfectant 13. Turn the disinfectant On/Off valve to the Off position. Wand 14. Return disinfectant wand to its holder. 15. After scrubbing the interior surfaces, leave the disinfectant in the loop and on the tub surfaces for ten Overflow minutes. 16. Use the shower/massage wand on the pulse setting and Whirlpool Jets direct the spray into both whirlpool jets to back flush until the water discharging from the whirlpool inlet is Whirlpool Inlet clear. 17. Rinse all interior tub surfaces. 18. Reverse STEPS 2 and 3 to open the whirlpool jets and FIGURE 2.1 Disinfecting the Tub Using the Closed Loop whirlpool inlet. System Supine Bath Tub 12 Part No 1096926 SECTION 3—OPERATION SECTION 3—OPERATION Overview The tub is designed to improve the efficiency and environmental safety of your facilityʹs operation. However, if the tub is not operated or maintained properly, the benefits designed into the system will not be realized. The purpose of this manual is to provide you with recommended procedures to help you obtain the maximum efficiency and safety while using your tub. When using the tub, perform these procedures in the following order: 1. Preparing the tub for use 2. Transferring the resident into the tub 3. Bathing 4. Transferring the resident from the tub Preparing the Tub for Use NOTE: For this procedure, refer to FIGURE 3.1. NOTE: Make sure that your tub has been disinfected before preparing the tub for use. Turn CounterClockwise To Open NOTE: This procedure must be performed after disinfecting the tub to finalize the disinfecting process. Whirlpool Jet 1. Open the whirlpool inlet by pushing the inlet plug in the center of the inlet cover in until it stops. Pull Out To Open Shower/ Massage Wand 2. Open all whirlpool jets by performing one of the following: • Turn the center jet counter‐ clockwise to a full stop. • Pull the center of the jet out. Whirlpool Inlet Inlet Plug 3. Using shower/massage wand on Pulse setting, direct water spray into the whirlpool jets to back‐flush the system until water coming from the whirlpool inlet is clear. Refer to Operating Shower/ Massage Wand on page 15. 4. Rinse all interior tub surfaces with shower/massage wand on Spray setting. FIGURE 3.1 Preparing the Tub for Use 5. Visually inspect tub for damage and to ensure that all tub surfaces are clean and that no visible disinfectant residue remains. Part No 1096926 13 Supine Bath Tub SECTION 3—OPERATION Operating the Tub WARNING DO NOT stand in tub. Tub surfaces are slippery when wet. Serious injury may occur. DO NOT stand on tub frame. Frame is slippery when wet. BEFORE immersing the resident or operating the shower/massage wand, check that the water temperature is between 95° F and 105° F (35° C and 41° C) to avoid scalding the resident. Disinfect the tub after EACH use to avoid resident contamination. NOTE: For this procedure, refer to FIGURE 3.2. Using Water Temperature Setting Flow Water Thermometer ‐ Measures the temperature of water coming from the tub fill spout or shower/massage wand. Water Temperature Control Valve ‐ Sets and maintains constant temperature for all incoming water. WARNING ALWAYS hand test the incoming water temperature and the water temperature in the tub BEFORE immersing the resident. Failure to do so may result in a scalding injury. Model IH6300 Tub Fill ON/OFF Flow Water Thermometer Model IH6300ADH Tub Fill ON/OFF Shower ON/OFF Flow Water Thermometer Water Temperature Control Valve Whirlpool Aerator Whirlpool On/Off Whirlpool On/Off FIGURE 3.2 Supine Bath Tub Shower ON/OFF Tub Control Up Tub Control Down Using Water Temperature Setting 14 Part No 1096926 SECTION 3—OPERATION Operating Shower/Massage Wand NOTE: STEPS 1 ‐ 3 are to be performed while holding the shower/massage wand over the tub. Refer to Features on page 8 for additional illustrations. 1. Turn shower/massage wand on to desired flow by rotating knob. 2. Adjust water temperature while watching thermometer. 3. Adjust shower spray by rotating shower wand head. NOTE: Refer to the following chart for shower head adjustment settings. Stream Shower Spray Mixture of Spray and Pulse Massage Pulse Massage 4. Turn shower On/Off knob to Off position when finished. Filling the Tub 1. Close the drain. 2. Turn tub fill On/Off valve to On position by rotating knob. 3. Adjust water temperature while watching thermometer. 4. Turn tub fill On/Off valve to Off position when water reaches desired level. NOTE: If hydromassage use is anticipated, water level MUST be completely above whirlpool jets. NOTE: Before starting hydromassage, open the whirlpool inlet and whirlpool jets. Using Hydromassage CAUTION Before starting hydromassage, water level MUST be completely above whirlpool jets otherwise damage to the motor/pump will result. 1. Open the whirlpool inlet by pushing in on the plug in the whirlpool inlet fitting. 2. Open all whirlpool jets by performing one of the following: • Turn the center of the jet counter‐clockwise to a full stop. • Pull the center of the jet out. 3. Add Invacare Defoamer to bath water. Refer to Defoamer bottle for directions. 4. Push whirlpool On/Off button to start whirlpool jets. 5. Adjust the whirlpool aerator for desired water agitation by rotating the knob. 6. After use, push whirlpool On/Off button to stop whirlpool jets. 7. Drain the tub. Part No 1096926 15 Supine Bath Tub SECTION 3—OPERATION Adjusting Tub Height - Model IH6300ADH ONLY WARNING DO NOT stand on tub frame. Frame is slippery when wet. Foot injury is possible when adjusting tub height. CAUTION DO NOT adjust height more than three cycles (up and down) within a ten minute period. Damage to the actuator may result. NOTE: The supine tub stops automatically when maximum height adjustment Up or Down is reached. Raising the Supine Tub 1. Press and hold tub control Up button. 2. Release tub control Up button when desired height is reached. Lowering the Supine Tub 1. Press and hold tub control Down button. 2. Release tub control Down button when desired height is reached. Supine Bath Tub 16 Part No 1096926 SECTION 4—INSTALLATION SECTION 4—INSTALLATION Preparing the Work Area NOTE: For this procedure, refer to FIGURE 4.1. 1. Determine location for the supine bath tub installation. NOTE: Follow recommended floor plan when installing tub. 2. Carefully remove the tub from carton. 3. Remove tub from shipping pallet by removing screws from leg mounting pads. 4. Model IH6300 ONLY ‐ Remove the screws that secure the rear access panel to access the pump electrical connections (Detail “A” of FIGURE 4.1). DETAIL "A" 142 inches (3606 mm) 3 ft (914 mm) Access Panel Wall 38 in. (965 mm) 3 ft (914 mm) Screw (1 of 4) 3 ft (914 mm) 94 inches (2388 mm) 1 ft (304 mm) Leg Mounting Pads FIGURE 4.1 Preparing the Work Area Part No 1096926 17 Supine Bath Tub SECTION 4—INSTALLATION Securing the Tub NOTE: For this procedure, refer to FIGURE 4.1 on page 17 and FIGURE 4.2. 1. Set the tub in place. 2. Mark location of anchor holes, using pre‐drilled holes in leg mounting pads as a template (Detail “A” of FIGURE 4.1). 3. Move tub away from mounting area. WARNING Protective eye wear MUST be worn when drilling to avoid possible eye injury. 4. Drill anchor holes in floor. Use a jack‐drill with a carbide bit for concrete floors or a wood bit for wood floors. 5. Reposition the tub in mounting area, aligning the holes in the leg mounting pads with the holes drilled in STEP 4. WARNING DO NOT adjust height of legs more than 1 inch (25.4 mm); leg will disassemble from leg mounting pad and serious injury may occur. 6. Level the tub by adjusting the telescopic legs either up or down, using a wrench, to achieve the desired height. 7. Check to make sure tub is level by placing a level on the front and sides of the tub (Detail “A” of FIGURE 4.2). 8. Repeat STEPS 6 and 7 until tub is level. 9. Secure legs to floor using fasteners appropriate for the floor material and in keeping with local codes (Detail “B” of FIGURE 4.2). DETAIL “A” - LEVELING DETAIL “B” - SECURING TUB Level Leveling Side to Side Leg 1-inch (25.4 mm) Maximum Adjustment Lag Bolt Level Anchor Leveling End to End Lag Bolt Leg Mounting Pad Anchor FIGURE 4.2 Securing the Tub Supine Bath Tub 18 Part No 1096926 SECTION 4—INSTALLATION Electrical Hook-up WARNING Be certain ALL electrical work is performed by a qualified electrician and is in compliance with local electrical codes. Before installing and connecting the tub, make certain that the electric power source is SHUT OFF to avoid electrical shock. NOTE: For this procedure, refer to FIGURE 4.3 on page 20. NOTE: For installation details refer to on page 20. 1. Install the electrical hook‐ups per FIGURE 4.3. Part No 1096926 19 Supine Bath Tub SECTION 4—INSTALLATION DETAIL “A” - ELECTRICAL HOOK UP LOCATION Electrical Hookup DETAIL “B” - ELECTRICAL HOOK UP DETAILS IH6300 Fixed Height Use 15 Amp GFCI Breaker Only IH6300ADH Adjustable Height Use 15 Amp Hospital Grade GFCI Receptacle Only 115 V Electrical DETAIL “C” - ELECTRICAL SCHEMATIC GREEN WHITE BLACK Wall Tub Wall Pump Motor DETAIL “E” - MOTOR END PLATE DETAIL “D” - MOTOR COVER Air Switch Line Ground (GREEN) Motor Cover Line Line (BLACK) Neutral (WHITE) Neutral Ground FIGURE 4.3 Electrical Hook-up Supine Bath Tub 20 Part No 1096926 SECTION 4—INSTALLATION Electrical Installation DANGER The National Electric Code requires the use of a ground fault circuit interrupter on all therapeutic pools and tubs (hydrotherapeutic tanks). Failure to follow this requirement could result in serious or fatal injury. ELECTRICAL SHOCK HAZARD. All disassembly and maintenance of the tub MUST be done by a qualified technician, certified electrician or plumber. Disconnect electrical supply or turn OFF circuit breaker before performing any maintenance to the tub. WARNING Be certain ALL electrical work is performed by a qualified electrician and is in compliance with local electrical codes. All electrical conduit, fittings and wire to unit are to be supplied and installed by a professional electrician in accordance with the National electrical code as a minimum requirement, including the supply and installation of a Ground Fault Circuit Interrupter (GFCI). Before installing and connecting the tub, make certain that the electrical power source is shut off to avoid electrical shock. NOTE: For this procedure, refer to FIGURE 4.4. 1. Install a 115V electrical hook‐up per local electrical codes. 2. For Model IH6300, perform the following: A. Remove the screws that attach the rear access panel to the tub. B. Route electrical line through electrical line routing hole in tub frame. C. Connect ground, neutral and hot wires from wall directly to motor through the electrical line routing hole. I DETAIL “A” - MODEL IH6300 Motor Rear Access (Panel Removed) Screw (1 of 4) Electrical Line Routing Hole DETAIL “B” - MODEL IH6300ADH DANGER Model IH6300ADH - Electric shock hazard. Use only with hospital grade GFCI receptacle. Failure to do so may result in an electrical shock and/or serious or fatal injury. Hospital Grade Plug 3. For Model IH6300ADH ‐ Plug hospital grade plug into pre‐installed GFCI protected hospital grade receptacle (Detail “B” of FIGURE 4.4). Part No 1096926 FIGURE 4.4 Electrical Installation 21 Supine Bath Tub SECTION 4—INSTALLATION Plumbing Hook-Up WARNING Be certain ALL plumbing work is performed by a qualified plumber and is in compliance with local codes. NOTE: For this procedure, refer to Refer to FIGURE 4.5. NOTE: For installation details refer to Plumbing Installation on page 23. CAUTION The 2 inch PVC stub MUST be recessed into the floor to make the elbow flush with the floor. For Model IH6300ADH, this will allow smooth up and down movement of the hose. Otherwise, drain tubing and fittings could be crushed at low point of operation. 1. Install the plumbing hook‐ups per FIGURE 4.5. DETAIL “A” - HOOK UP LOCATIONS 3.5 in (89 mm) 10.0 in 6.5 in (165 mm) (254 mm) 5.5 in (140 mm) Cold Hot DETAIL “B” - DRAIN AND ROUGH-IN LOCATIONS 3/4 in. Ball Valve MUST be a minimum of 6 in above the floor Drain Centerline of Tub Wall 36 in. (915 mm) 6 in. (152 mm) Tub Front of Tub 2 in. PVC stub Back of Tub Elbow Drain FIGURE 4.5 Plumbing Hook-Up Supine Bath Tub 22 Part No 1096926 SECTION 4—INSTALLATION Plumbing Installation WARNING Be certain ALL plumbing work is performed by a qualified plumber. Some state and local plumbing codes require the installation of a “reduced pressure zone” (RPZ) assembly on both the incoming hot and cold supply lines to prevent back flow contamination into the potable water system. Invacare recommends you check local plumbing code requirements to determine if RPZs are required on your tub installation. RPZs are NOT supplied by Invacare and are to be provided by the customer if required. The hot water supply to the tub MUST NOT exceed 110o F (43° C) to protect the user from scalding. CAUTION Purge water lines. Hot and cold lines MUST be purged (blown down) to clear lines of debris prior to connection. Valves and spray heads may become inoperable and/ or damaged if lines are not properly cleared. Items damaged in this way are not covered under the warranty. When operating water pressure exceeds 55 PSI, pressure regulators (similar to the ¾-inch Watts U5) MUST be installed. NOTE: For this procedure, refer to FIGURE 4.6 on page 24. 1. Purge water lines. Hot and cold lines MUST be purged (blown down) prior to connection, to clear lines of debris. 2. Connect hot and cold supply lines to appropriate copper stubs found on back of tub (Detail “A” of FIGURE 4.6). 3. Install On/Off valves at wall and use unions between valves and stubs. 4. Connect drains in accordance with local plumbing codes. 5. Assemble hand held shower and disinfectant wands. 6. Check operation of tub according to operating instructions. NOTE: Check local codes regarding maximum water temperature allowed at hot water outlets for facility type. Part No 1096926 23 Supine Bath Tub SECTION 4—INSTALLATION DETAIL “A” - PLUMBING INSTALLATION Cold Water Inlet Hot Water Inlet DETAIL “B” - PLUMBING SCHEMATIC In House Water Service HOT COLD Check Valve Optional Pressure Regulator Shower/Massage Wand RADA Mixing Valve Shower/Massage Wand Valve Back Flow Preventer Disinfectant Line Tub Fill Valve Disinfectant Valve Jet Intake Pump Tub Fill Disinfectant Injector Disinfectant Line Flow meter Disinfectant Wand Invacare Disinfectant Check Valve Disinfectant Line to Jets and Intake Back Flow Preventer Drain from Overflow Drain Disinfectant Line to Wand FIGURE 4.6 Plumbing Installation and Schematic Supine Bath Tub 24 Part No 1096926 SECTION 5—MAINTENANCE SECTION 5—MAINTENANCE WARNING Before performing any maintenance to the tub, make certain that the electric power source is shut off to avoid electrical shock. Be certain ALL electrical work is performed by a qualified electrician and is in compliance with local codes. If any part of the system is NOT functioning properly, DO NOT use the system. Have the system serviced to correct the problem. The system MUST be maintained on a regular basis to ensure it is functioning properly. ELECTRICAL SHOCK HAZARD. All disassembly and maintenance of the tub MUST be done by a qualified technician, certified electrician or plumber. Disconnect electrical supply or turn OFF circuit breaker before performing any maintenance to the tub. Parts Information NOTE: For parts information, please contact Invacare Continuing Care Group Technical Service at (866) 616‐2631. NOTE: Every six months or as necessary, have a qualified technician perform a thorough inspection and servicing. Routine maintenance will extend the life and efficiency of your tub. Safety Inspection Checklists Initially ❑ Ensure that the maximum water supply temperature does not exceed 110° F (43°C). ❑ Ensure that the maximum water pressure does not exceed 65 PSI. ❑ Verify the water flow temperature with a separate thermometer. ❑ Visually inspect for cracks in the tub surface. ❑ Check that all labels are present and legible. Replace if necessary. Before Each Use ❑ Disinfect the tub. ❑ Ensure that the maximum water supply temperature does not exceed 110° F (43°C). ❑ Ensure that the maximum water pressure does not exceed 65 PSI. ❑ Visually inspect for cracks in the tub surface. Every 80-150 Baths ❑ Perform the heavy duty cleaning procedure on the tub. Refer to Heavy Duty Cleaning Procedure on page 27. Part No 1096926 25 Supine Bath Tub SECTION 5—MAINTENANCE Every Six Months ❑ Verify the water flow temperature with a separate thermometer. ❑ Visually inspect plumbing for leaks. ❑ Check that all labels are present and legible. Replace if necessary. ❑ IH6300ADH ONLY ‐ Re‐apply white lithium grease. Refer to Maintenance for IH6300ADH Adjustable Height ONLY Glide Pads on page 26. Maintenance for IH6300ADH Adjustable Height ONLY Glide Pads NOTE: For this procedure, refer to FIGURE 5.1. Glide Pad NOTE: Glide pads require white lithium grease applied twice a year. Rub Panel 1. Remove side panel to access glide pads. 2. Generously apply white lithium grease to stainless steel rub panel. 3. Repeat STEPS 1‐2 for the opposite side. 4. Replace side panels. FIGURE 5.1 Maintenance for IH6300ADH Adjustable Height ONLY Glide Pads Removing Soap Film and Hard Water Deposits Use a commercially available cleaner such as Invacare’s Heavy Duty Cleaner to thoroughly spray the exposed surfaces, including the openings of the tub jets and tub suction fitting. Use a long handled soft brush or similar product to wipe down all surfaces and allow the heavy duty cleaner to remain in contact with the exposed surfaces for approximately ten minutes. Rinse off surfaces using the shower wand, adjusted to spray position. Removing Calcium Deposits, Scale and Lime Build-up Spray a commercially available cleaner (full strength) for the intended application on all surfaces to be cleaned. Allow the cleaner to remain in contact with surfaces for at least five minutes to as long as 12 hours. Rinse off surfaces using the shower wand, adjusted to the spray position. Use the cleaner according to the manufacturer’s instructions. Supine Bath Tub 26 Part No 1096926 SECTION 5—MAINTENANCE Heavy Duty Cleaning Procedure WARNING DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as owner’s manuals, service manuals or instruction sheets supplied with this product or optional equipment. If you are unable to understand the warnings, cautions or instructions, contact a healthcare professional, dealer or technical personnel before attempting to use this equipment - otherwise, injury or damage may occur. The disinfectant dispensing system has been factory tested and calibrated for use with Invacare disinfectant. The use of any disinfectant with a dilution ratio (½ oz per gallon) or viscosity level different than that of Invacare disinfectant will result in an improper mixture of disinfectant and water. This may cause your system to be improperly disinfected - or in some instances, not disinfected at all. If using any disinfectant with a dilution ratio or viscosity level different than that of Invacare disinfectant or if switching from one type of disinfectant to another type, the disinfectant flowmeter must be calibrated before performing this procedure. Refer to the tub owner’s manual or to the calibration instruction sheet, part number 1154272, for the calibration procedure. ALWAYS wear rubber gloves, an apron and face shield protection during disinfecting, cleaning and rinsing procedures. In case of eye or skin contact, follow procedures on disinfectant container. CAUTION NEVER use abrasive cleaners like scouring powder or liquid cleaners containing pumice stone. The use of these types of cleaners will make the gel-coat finish of your tub scratched and dull. NEVER use cleaners containing iodine, bromine, Betadine or methylene blue. The use of these types of cleaners will cause the tub to stain. Never use cleaners containing bleach. Use of these types of cleaners will dry out the rubber seals and gaskets and the tub will not function properly. Before starting the whirlpool pump, the water level must be completely above the whirlpool jets. Otherwise damage to the motor/pump will result. In addition to disinfecting your tub after every use, you will need to perform this procedure approximately once every 80‐150 baths. 1. Clean the entire surface of the tub to remove visible tissue residue and fluid. 2. Rinse the inside surface of the tub with the shower/massage wand on the spray setting. 3. Rotate the water temperature valve to adjust the water temperature to 105o F. NOTE: This will maximize the cleaning solutionʹs ability to clean and disinfect the system. 4. Close the drain. 5. Make sure the whirlpool jets are open. NOTE: The required amount of water to cover the whirlpool jets is 50 gallons. 6. Fill the tub above the whirlpool jets. NOTE: The required amount of Invacare Heavy Duty Cleaner is 200 ounces. 7. Add the Invacare Heavy Duty Cleaner to the water in the tub. 8. Spray pre‐mixed Invacare Heavy Duty Cleaner on the remaining surfaces. 9. Press the whirlpool on/off button to turn on the whirlpool pump and let the pump run for 60 seconds. 10. Turn off the pump and allow the heavy duty cleaner/water solution to remain in the tub for 10 minutes. 11. During this ten‐minute waiting time, take a long handled brush and thoroughly scrub all interior surfaces of the tub. 12. Open the drain to allow the heavy duty/water solution to drain from the tub. 13. Use the shower/massage wand on the pulse setting and direct the spray into both whirlpool jets to back flush until the water discharging from the whirlpool inlet is clear. 14. Rinse the tub thoroughly with the shower wand on the spray setting. 15. Check the tub for damage and to ensure all surfaces of the tub are clean and that no visible residuals remain. If residuals are found, repeat STEPS 13 and 14. Part No 1096926 27 Supine Bath Tub SECTION 5—MAINTENANCE Calibrating the Disinfectant Flowmeter WARNING DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as owner’s manuals, service manuals or instruction sheets supplied with this product or optional equipment. If you are unable to understand the warnings, cautions or instructions, contact a healthcare professional, dealer or technical personnel before attempting to use this equipment - otherwise, injury or damage may occur. The disinfectant dispensing system has been factory tested and calibrated for use with Invacare disinfectant. The use of any disinfectant with a dilution ratio (½ oz. per gallon) or viscosity level different than that of Invacare disinfectant will result in an improper mixture of disinfectant and water. This may cause your system to be improperly disinfected - or in some instances, not disinfected at all. If using any disinfectant with a dilution ratio or viscosity level different than that of Invacare disinfectant or if switching from one type of disinfectant to another type, the disinfectant flowmeter MUST be calibrated using this procedure before disinfecting the tub. This procedure should only be attempted by qualified maintenance personnel. Failure to heed these precautions could result in injury to the tub operator or resident. ALWAYS wear rubber gloves, an apron and face shield protection during disinfecting, cleaning and rinsing procedures. In case of eye or skin contact, follow procedures on disinfectant container. NOTE: For this procedure, refer to FIGURE 5.2 on page 29. NOTE: Equipment needed: • • • Bucket or Pail, at least 1 Gallon Graduated plastic bottle, at least 16 ounces Felt Tip Pen 1. Open the whirlpool aerator by rotating two turns counterclockwise. 2. If the tub is equipped with a disinfectant wand, hold the wand over the interior of the tub. 3. Pour exactly one gallon of water into the bucket/pail. 4. Mark the bucket/pail at the gallon level using the felt tip pen. 5. Empty the bucket/pail. 6. Pour a whole number of ounces of disinfectant into the graduated plastic bottle. NOTE: For example, pour 2 or 3 ounces, but not 2½ ounces, otherwise the results will be skewed. NOTE: DO NOT use water instead of disinfectant. This would cause a false reading. 7. Note the number of ounces in the graduated plastic bottle. 8. Open the service access cabinet door. 9. Insert the disinfectant draw tube into the graduated plastic bottle. 10. Turn the black knob on the flow meter valve five turns counterclockwise to open the metering valve. 11. Close all jets by pushing the center of each jet in or turning the center of the jet clockwise. 12. Close the whirlpool inlet by pulling the inlet plug out. 13. Turn the disinfectant valve to the on position. NOTE: Liquid will be heard filling the interior plumbing of the tub. 14. Note the position of the floating ball in the flow meter. Supine Bath Tub 28 Part No 1096926 SECTION 5—MAINTENANCE 15. Adjust the injector by performing one of the following: • Bottom of Floating Ball Reads Greater Than 35 ‐ Less disinfectant needs to be added to the mixture. Loosen the screw on the injector to draw less disinfectant into the solution. • Bottom of Floating Ball Reads Less Than 35 ‐ More disinfectant needs to be added to the mixture. Tighten the screw on the injector to draw more disinfectant into the solution. 16. When the bottom of the floating ball is near 35, turn the black adjustment knob on the flow meter until the bottom of the floating ball is at 35. 17. Place the bucket/pail under the burp fitting to collect the disinfectant. Use a funnel if necessary. 18. Note the number of ounces in the graduated plastic bottle. 19. Let the bucket/pail fill to one gallon. 20. Turn the disinfectant valve to the off position. 21. Remove the disinfectant draw tube from the plastic bottle. 22. Examine the amount of disinfectant remaining in the plastic bottle. 23. Subtract the amount of disinfectant remaining from the amount noted in STEP 18. 24. Perform one of the following: • Approximately ½‐ounce of disinfectant has been used ‐ Proceed to STEP 23. • Much more or much less than ½‐ounce of disinfectant has been used ‐ repeat STEPS 1‐18. 25. Position the disinfectant draw tube into the disinfectant solution. 26. Disinfect the tub. Refer to Disinfecting the Tub Using the Closed Loop System on page 12. Adjustment Knob Flow meter Ball Disinfectant Cabinet Disinfectant Siphon Tube Disinfectant On/Off Valve Disinfectant Siphon Tube Injector Screw FIGURE 5.2 Calibrating the Disinfectant Flowmeter Part No 1096926 29 Supine Bath Tub SECTION 5—MAINTENANCE Maintenance Record DATE Supine Bath Tub MAINTENANCE PERSON TYPE OF MAINTENANCE PERFORMED 30 NOTES Part No 1096926 SECTION 6—TROUBLESHOOTING SECTION 6—TROUBLESHOOTING SYSTEM/OPERATION Adjustable Height Model IH6300ADH SYMPTOMS Tub will not raise or lower FAULTS SOLUTION Glide pads not greased Grease glide pads. Refer to Maintenance for IH6300ADH Adjustable Height ONLY Glide Pads on page 26. Bad electrical connections Check electrical connections at the control box. Actuator overloaded Wait 5 minutes and try adjusting height again. Actuator burned out Contact an Invacare Dealer. Obstacle in tub path Inspect and remove obstacle. No electrical power to tub Check and reset breaker or GFCI. Hydromassage System System will not start No electrical power to tub Check and reset breaker or GFCI. System not prepared Be sure water level is above jets. Check that inlet plug on tub is depressed. System is ineffective Disinfecting System Tub Operation No discharge from disinfectant wand No water flow Switch hose disconnected Reconnect hose to switch and motor. Water deposits in whirlpool jets Disassemble and clean whirlpool jets. Whirlpool jets closed Open whirlpool jets. Aerator closed Open aerator. Whirlpool intake clogged Inspect intake and remove obstruction. Whirlpool jets open Close whirlpool jets. Whirlpool intake open Close whirlpool intake. Hose kinked Inspect hose and unkink. Disinfectant siphon tube kinked Inspect siphon tube and unkink. Flow meter adjustment knob turned off Turn flow meter adjustment knob to proper setting. Water supply turned off Turn on water supply. Restricted water flow RADA valve. Refer to RADA owner’s manual. Inspect and clean RADA valve. NOTE: If problems are not remedied by the suggested means above, contact an Invacare Dealer. Part No 1096926 31 Supine Bath Tub LIMITED WARRANTY PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975. This warranty is extended only to the original purchaser/user of our products. This warranty gives you specific legal rights and you may also have other legal rights which vary from state to state. Invacare Continuing Care Group (ICCG) warrants its bathing/whirlpool products to be free from defects in materials and workmanship for a period of three years from the date of purchase. Warranty obligation is limited to parts replacement only. Warranty replacement parts are only covered for the duration of the warranty period. All purchased replacement parts will carry a 30-day warranty from the date of shipment. If within such warranty period any such product shall be proven to be defective, such product shall be repaired or replaced, at ICCG's option. This warranty does not include any labor or shipping charges incurred in replacement part installation or repair of any such product. ICCG's sole obligation and your exclusive remedy under this warranty shall be limited to such repair and/or replacement. For warranty service, please contact the dealer from whom you purchased your ICCG product. In the event you do not receive satisfactory warranty service, please write directly to ICCG at the address below. Provide dealer's name, address, model number, date of purchase, indicate nature of the defect and, if the product is serialized, indicate the serial number. ICCG will issue a return authorization. The defective unit or parts must be returned for warranty inspection using the serial number, when applicable, as identification within thirty days of return authorization date. DO NOT return products to our factory without our prior consent. C.O.D. shipments will be refused; please prepay shipping charges. LIMITATIONS AND EXCLUSIONS: THE WARRANTY SHALL NOT APPLY TO PROBLEMS ARISING FROM NORMAL WEAR OR FAILURE TO ADHERE TO THE ENCLOSED INSTRUCTIONS. LABOR; EXPENDABLE ITEMS, I.E. SHOWER HOSES, VALVES, “O” RINGS, SEALS; PARTS BROKEN DUE TO ABUSE OR IMPROPER USE; ITEMS THAT BECOME INOPERABLE DUE TO LACK OF MAINTENANCE, OR NON COMPATIBLE CHEMICALS; STAINS DUE TO HARD WATER, IODINE SOLUTIONS, OR OTHER UNAPPROVED CHEMICALS; “SPIDER” CRACKS OR “CRACKING” DUE TO MISHANDLING OR ABUSE. IN ADDITION, THE FOREGOING WARRANTY SHALL NOT APPLY TO SERIAL NUMBERED PRODUCTS IF THE SERIAL NUMBER HAS BEEN REMOVED OR DEFACED; PRODUCTS SUBJECTED TO NEGLIGENCE, ACCIDENT, IMPROPER OPERATION, MAINTENANCE OR STORAGE; OR PRODUCTS MODIFIED WITHOUT ICCG'S EXPRESS WRITTEN CONSENT INCLUDING, BUT NOT LIMITED TO: MODIFICATION THROUGH THE USE OF UNAUTHORIZED PARTS OR ATTACHMENTS: PRODUCTS DAMAGED BY REASON OF REPAIRS MADE TO ANY COMPONENT WITHOUT THE SPECIFIC CONSENT OF ICCG; PRODUCTS DAMAGED BY CIRCUMSTANCES BEYOND ICCG'S CONTROL; PRODUCTS REPAIRED BY ANYONE OTHER THAN AN ICCG DEALER, SUCH EVALUATION SHALL BE SOLELY DETERMINED BY ICCG. THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES WHATSOEVER, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND THE SOLE REMEDY FOR VIOLATIONS OF ANY WARRANTY WHATSOEVER, SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT PURSUANT TO THE TERMS CONTAINED HEREIN. THE APPLICATION OF ANY IMPLIED WARRANTY WHATSOEVER SHALL NOT EXTEND BEYOND THE DURATION OF THE EXPRESS WARRANTY PROVIDED HEREIN. THE MANUFACTURER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER. THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE/PROVINCIAL LAWS AND REQUIREMENTS. Invacare Continuing Care Group www.invacare-ccg.com USA One Invacare Way Elyria, Ohio USA 44036-2125 All rights reserved. Trademarks are identified by the symbols ™ and ®. All trademarks are owned by or licensed to Invacare Corporation unless otherwise noted. Betadine is a registered trademark of Purdue Pharma L.P. ©2008 Invacare Corporation Canada 994 Hargrieve Rd. London Ontario N6E 1P5 Canada Part No 1096926 For customer service: 800-668-2337 Rev E - 4/08
advertisement
Related manuals
advertisement