Lucent Technologies APX 8000 MAX TNT, DSLTNT Network device Administration Guide
Below you will find brief information for Network device APX 8000 MAX TNT, Network device APX 8000 DSLTNT. These network devices are designed to provide high-speed, reliable data connectivity for businesses and organizations. They offer a wide range of features and capabilities, including support for various network protocols, security features, and remote management capabilities.
Advertisement
Advertisement
APX 8000
™
/MAX TNT
®
/DSLTNT
™
Administration Guide
Part Number: 7820-0804-002
For software version 8.0
May 2000
Copyright© 2000 Lucent Technologies. All rights reserved.
This material is protected by the copyright laws of the United States and other countries. It may not be reproduced, distributed, or altered in any fashion by any entity (either internal or external to Lucent Technologies), except in accordance with applicable agreements, contracts, or licensing, without the express written consent of Lucent Technologies. For permission to reproduce or distribute, please email your request to [email protected]
.
Notice
Every effort was made to ensure that the information in this document was complete and accurate at the time of printing, but information is subject to change.
Safety, Compliance, and Warranty Information
Before handling any Lucent Access Networks hardware product, read the Access Networks Safety and Compliance Guide included in your product package.
See that guide also to determine how products comply with the electromagnetic interference (EMI) and network compatibility requirements of your country.
See the warranty card included in your product package for the limited warranty that Lucent Technologies provides for its products.
Security Statement
In rare instances, unauthorized individuals make connections to the telecommunications network through the use of access features.
Trademarks
4ESS, 5ESS, A Network of Expertise, AnyMedia, AqueView, AUDIX, B-STDX 8000, B-STDX 9000, Beyond Compare, CaseView, Cajun, CajunDocs,
CAJUNVIEW, Callmaster, CallVisor, CBX 500, CellPipe, ChoiceNet, ClearReach, ComOS, cvMAX, DACScan, Dacsmate, Datakit, DEFINITY,
Definity One, DSLMAX, DSL Terminator, DSLPipe, DSLTNT, Elemedia, Elemedia Enhanced, EMMI, End to End Solutions, EPAC, ESS, EVEREST,
Gigabit-scaled campus networking, Globalview, GRF, GX 250, GX 550, HyperPATH, Inferno, InfernoSpaces, Intragy, IntragyAccess, IntragyCentral,
Intuity, IP Navigator, IPWorX, LineReach, LinkReach, MAX, MAXENT, MAX TNT, Multiband, Multiband PLUS, Multiband RPM, MultiDSL, Multi-
Voice, MultiVPN, Navis, NavisAccess, NavisConnect, NavisCore, NavisRadius, NavisXtend, NetCare, NetLight, NetPartner, OneVision,
Open Systems Innovations, OpenTrunk, P550, PacketStar, PathStar, Pinnacle, Pipeline, PMVision, PortMaster, SecureConnect, Selectools, Series56,
SmoothConnect, Stinger, SYSTIMAX, True Access, WaveLAN, WaveMANAGER, WaveMODEM, WebXtend, and Where Network Solutions Never End are trademarks of Lucent Technologies. Advantage Pak, Advantage Services, AnyMedia, Beyond Compare, End to End Solutions, Inter.NetWorking,
MAXENT, and NetWork Knowledge Solutions are service marks of Lucent Technologies. Other trademarks, service marks, and trade names mentioned in this publication belong to their respective owners.
Copyrights for Third-Party Software Included in Lucent Access Networks Software Products
C++ Standard Template Library software copyright© 1994 Hewlett-Packard Company and copyright© 1997 Silicon Graphics. Permission to use, copy, modify, distribute, and sell this software and its documentation for any purpose is hereby granted without fee, provided that the above copyright notice appear in all copies and that both that copyright notice and this permission notice appear in supporting documentation. Neither Hewlett-Packard nor Silicon Graphics makes any representations about the suitability of this software for any purpose. It is provided “as is” without express or implied warranty.
Berkeley Software Distribution (BSD) UNIX software copyright© 1982, 1986, 1988, 1993 The Regents of California. All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1. Redistributions of source code must retain the above copyright notice, this list of conditions, and the following disclaimer. 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions, and the following disclaimer in the documentation and/or other materials provided with the distribution. 3. All advertising materials mentioning features or use of this software must display the following acknowledgement: This product includes software developed by the University of California, Berkeley, and its contributors. 4. Neither the name of the University nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS “AS IS” AND ANY EXPRESS OR IMPLIED WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
OR SERVICES; LOSS OF USE, DATA OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF
LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Ordering Information
You can order the most up-to-date product information and computer-based training online at http://www.lucent.com/ins/bookstore
.
Feedback
Lucent Technologies appreciates your comments, either positive or negative, about this manual. Please send them to [email protected]
.
Lucent Technologies
Customer Service
Customer Service provides a variety of options for obtaining information about Lucent products and services, software upgrades, and technical assistance.
Finding information and software on the Internet
Visit the Web site at http://www.lucent.com/ins for technical information, product information, and descriptions of available services.
Visit the FTP site at ftp://ftp.ascend.com
for software upgrades, release notes, and addenda.
Obtaining technical assistance
You can obtain technical assistance by telephone, email, fax, modem, or regular mail, as well as over the Internet.
Gathering information you will need
If you need to contact Lucent for help with a problem, make sure that you have the following information when you call or that you include it in your correspondence:
• Product name and model
• Software and hardware options
• Software version
• If supplied by your carrier, Service Profile Identifiers (SPIDs) associated with your line
• Your local telephone company’s switch type and operating mode, such as AT&T 5ESS
Custom or Northern Telecom National ISDN-1
• Whether you are routing or bridging with your Lucent product
• Type of computer you are using
• Description of the problem
Calling Lucent from within the United States
In the U.S., you can take advantage of Priority Technical Assistance or an Advantage service contract, or you can call to request assistance.
Priority Technical Assistance
If you need to talk to an engineer right away, call (900) 555-2763 to reach the Priority Call queue. The charge of $2.95 per minute does not begin to accrue until you are connected to an engineer. Average wait times are less than 3 minutes.
Advantage Services
Advantage Services is a comprehensive selection of services. Installation services help get your Lucent Wide Area Network (WAN) off to the right start. Ongoing maintenance and
APX 8000/MAX TNT/DSLTNT Administration Guide iii
support services provide hardware and software solutions to keep your network operating at peak performance. For more information, call (800) 272-3634.
Other telephone numbers
For a menu of Lucent’s services, call (800) 272-3634. Or call (510) 769-6001 for an operator.
Calling Lucent from outside the United States
You can contact Lucent by telephone from outside the United States at one of the following numbers:
Telephone outside the United States
Austria/Germany/Switzerland
Benelux
France
Italy
Japan
Middle East/Africa
Scandinavia
Spain/Portugal
UK
(510) 769-8027
(+33) 492 96 5672
(+33) 492 96 5674
(+33) 492 96 5673
(+33) 492 96 5676
(+81) 3 5325 7397
(+33) 492 96 5679
(+33) 492 96 5677
(+33) 492 96 5675
(+33) 492 96 5671
For the Asia-Pacific region, you can find additional support resources at http://www.lucent.com/ins/international/apac/
.
Obtaining assistance through correspondence
Send your technical support questions to one of the following email addresses, or correspond by fax, BBS, or regular mail with Customer Service in Lucent’s U.S. offices in Alameda, CA:
• Email from within the U.S.— [email protected]
• Email from Europe, the Middle East, or Africa—
• Email from the Asia-Pacific region— [email protected]
• Fax—(510) 814-2312
• Customer Support BBS (by modem)—(510) 814-2302
• Write to Lucent at the following address:
Attn: Customer Service
Lucent Technologies
1701 Harbor Bay Parkway
Alameda, CA 94502-3002
USA iv APX 8000/MAX TNT/DSLTNT Administration Guide
Contents
Chapter 1
About This Guide ........................................................................... xvii
Administering Slot Cards............................................................... 1-1
APX 8000/MAX TNT/DSLTNT Administration Guide v
Contents
Chapter 2
vi
TAOS System Administration ........................................................ 2-1
APX 8000/MAX TNT/DSLTNT Administration Guide
Contents
Chapter 3
Network Administration ................................................................. 3-1
Using the Netstat command to display the routing table ......................................... 3-5
APX 8000/MAX TNT/DSLTNT Administration Guide vii
Contents
Chapter 4
Chapter 5
viii
Using Debug Commands ............................................................... 4-1
Creating User Profiles .................................................................... 5-1
APX 8000/MAX TNT/DSLTNT Administration Guide
Contents
Chapter 6
Overview of RADIUS pseudo-user profile settings .............................................. 5-11
Examples of configuring a filter profile in RADIUS ............................................ 5-12
SNMP Administration ..................................................................... 6-1
RFC 2574 (SNMPv3 User-Based Security Model (USM) MIB)............................ 6-5
Ascend Advanced Agent MIB (advanced.mib)..................................................... 6-11
Ascend Answer Profile MIB (mibanswer.mib) ..................................................... 6-11
Ascend Frame Relay Profile MIB (mibfrmrl.mib) ................................................ 6-14
Ascend Service Management MIB (srvcmgmt.mib) ............................................. 6-15
Ascend UDS3 Profile MIB (mibuds3net.mib) ...................................................... 6-16
Ascend WAN Dialout MIB (wandialout.mib) ...................................................... 6-16
APX 8000/MAX TNT/DSLTNT Administration Guide ix
Contents
Chapter 7
x
Using Administrative Profiles........................................................ 7-1
APX 8000/MAX TNT/DSLTNT Administration Guide
Contents
Appendix A
Getting TAOS Unit Core Dumps .................................................... A-1
Appendix B
Log Messages on the TAOS Unit................................................... B-1
Syslog messages initiated by a Secure Access Firewall .......................................... B-9
Appendix C
PPP Decoding Primer ..................................................................... C-1
APX 8000/MAX TNT/DSLTNT Administration Guide xi
Figures
APX 8000/MAX TNT/DSLTNT Administration Guide xiii
Tables
APX 8000/MAX TNT/DSLTNT Administration Guide xv
About This Guide
What is in this guide
This guide describes how to manage and troubleshoot the APX 8000™, MAX TNT®, and
DSLTNT™ TAOS units. It assumes that you have set up your unit as described in the APX
8000 Hardware Installation Guide, or the MAX TNT/DSLTNT Hardware Installation Guide, and the APX 8000/MAX TNT/DSLTNT Physical Configuration Guide. You must also have the unit configured for network connectivity as described in the APX 8000/MAX TNT/DSLTNT
WAN, Routing, and Tunneling Configuration Guide.
Each chapter in the guide focuses on a particular aspect of TAOS unit administration and operations. The chapters describe tools for system management, network management, and
SNMP management.
Although some of the sections in this manual deal with security issues, the APX 8000/MAX
TNT/DSLTNT WAN, Routing, and Tunneling Configuration Guide provides a more comprehensive approach to such topics as securing the unit, using firewalls, and understanding the more complex authentication procedures (such as the use of dynamic passwords).
To perform many of the tasks in this manual, you must have administrative permission on the
TAOS unit. For instructions on logging into the TAOS unit with administrative permissions,
see “Logging into the TAOS unit” on page 2-2.
Note:
This manual describes the full set of features for APX 8000, MAX TNT, and DSLTNT units running True Access™ Operating System (TAOS) software version 8.0.2 or later. Some features might not be available with earlier versions or specialty loads of the software.
This manual hereafter refers to your product as a TAOS unit.
!
Warning:
Before installing your TAOS unit, be sure to read the safety instructions in the
Access Networks Safety and Compliance Guide. For information specific to your unit, see the
“Safety-Related Electrical, Physical, and Environmental Information” appendix in your unit’s hardware installation guide.
What you should know
This guide is for the person who installs, configures, and maintains a TAOS unit. To configure a unit, you need to understand the following:
• Internet or telecommuting concepts
• Wide Area Network (WAN) concepts
• Local Area Network (LAN) concepts, if applicable
APX 8000/MAX TNT/DSLTNT Administration Guide xvii
About This Guide
Documentation conventions
Documentation conventions
Following are all the special characters and typographical conventions used in this manual:
Convention Meaning
|
>
Monospace text Represents text that appears on your computer’s screen, or that could appear on your computer’s screen.
Boldface monospace text
Represents characters that you enter exactly as shown (unless the characters are also in
italics
—see Italics, below). If you could enter the characters but are not specifically instructed to, they do not appear in boldface.
Italics
[ ]
Represent variable information. Do not enter the words themselves in the command. Enter the information they represent. In ordinary text, italics are used for titles of publications, for some terms that would otherwise be in quotation marks, and to show emphasis.
Square brackets indicate an optional argument you might add to a command. To include such an argument, type only the information inside the brackets. Do not type the brackets unless they appear in bold type.
Separates command choices that are mutually exclusive.
Key1-Key2
Points to the next level in the path to a parameter or menu item. The item that follows the angle bracket is one of the options that appears when you select the item that precedes the angle bracket.
Represents a combination keystroke. To enter a combination keystroke, press the first key and hold it down while you press one or more other keys. Release all the keys at the same time. (For example,
Ctrl-H means hold down the Control key and press the H key.)
Press Enter
Note:
Means press the Enter, or Return, key or its equivalent on your computer.
Introduces important additional information.
!
Caution:
!
Warning:
Warns that a failure to follow the recommended procedure could result in loss of data or damage to equipment.
Warns that a failure to take appropriate safety precautions could result in physical injury.
Warns of danger of electric shock.
Warning:
xviii APX 8000/MAX TNT/DSLTNT Administration Guide
About This Guide
Documentation set
Documentation set
The APX 8000/MAX TNT/DSLTNT documentation set consists of the following manuals.
•
Read me first:
–
Access Networks Safety and Compliance Guide
Contains important safety instructions and country-specific compliance information that you must read before installing a TAOS unit.
–
TAOS Command-Line Interface Guide
Introduces the TAOS command-line environment and shows how to use the command-line interface effectively. This manual describes keyboard shortcuts and introduces commands, security levels, profile structure, and parameter types.
•
Installation and basic configuration:
– APX 8000 Hardware Installation Guide
Shows how to install APX 8000 hardware and includes APX 8000 technical specifications.
– MAX TNT/DSLTNT Hardware Installation Guide
Shows how to install MAX TNT and DSLTNT hardware and includes technical specifications for these units.
– APX 8000/MAX TNT/DSLTNT Physical Interface Configuration Guide
Shows how to configure the cards installed in a TAOS unit and their line attributes for such functions as framing, signaling, and channel usage. It also describes how calls are routed through the system and includes information about configuring the unit in a
Signaling System 7 (SS7) environment. This guide explains shelf controller redundancy for an APX 8000 unit.
•
Configuration:
– APX 8000/MAX TNT/DSLTNT ATM Configuration Guide
Describes how to configure Asynchronous Transfer Mode (ATM) operations on a
TAOS unit. This guide explains how to configure physical layer attributes and how to create permanent virtual circuit (PVC) and switched virtual circuit (SVC) ATM interfaces. It includes information about ATM direct and ATM-Frame Relay circuits.
– APX 8000/MAX TNT/DSLTNT Frame Relay Configuration Guide
Describes how to configure Frame Relay operations on a TAOS unit. This guide explains physical layer configuration and restrictions and how to create permanent virtual circuit (PVC) and switched virtual circuit (SVC) interfaces. It includes information about Multilink Frame Relay (MFR) and link management, as well as
Frame Relay and Frame Relay direct circuits.
– APX 8000/MAX TNT/DSLTNT WAN, Routing, and Tunneling Configuration Guide
Shows how to configure LAN and WAN routing for analog and digital dial-in connections on a TAOS unit. This guide includes information about IP routing, Open
Shortest Path First (OSPF) routing, Internet Group Management Protocol (IGMP) routing, multiprotocol routers, Virtual Routers (VRouters), and tunneling protocols.
– MultiVoice™ for MAX TNT/DSLTNT Configuration Guide
Shows how to configure the MultiVoice application to run on a MAX TNT unit in both Signaling System 7 (SS7) and H.323 Voice over IP (VoIP) configurations.
APX 8000/MAX TNT/DSLTNT Administration Guide xix
About This Guide
Documentation set
• RADIUS: TAOS RADIUS Guide and Reference
Describes how to set up a TAOS unit to use the Remote Authentication Dial-In User
Service (RADIUS) server and contains a complete reference to RADIUS attributes.
• Administration and troubleshooting: APX 8000/MAX TNT/DSLTNT Administration
Guide (this guide),
Describes how to administer a TAOS unit, including how to monitor the system and cards, troubleshoot the unit, and configure the unit to use the Simple Network Management
Protocol (SNMP).
•
Reference:
–
APX 8000/MAX TNT/DSLTNT Reference
An alphabetic reference to all commands, profiles, and parameters supported on
TAOS units.
– TAOS Glossary
Defines terms used in documentation for TAOS units.
xx APX 8000/MAX TNT/DSLTNT Administration Guide
Administering Slot Cards
1
Typical system administration tasks for the TAOS unit’s slot cards include viewing status information, removing a slot card configuration, and disabling lines. For information about
managing your TAOS unit, see Chapter 2, “TAOS System Administration.”
Viewing installed slot cards
The Show command displays information about the slot cards installed in the TAOS unit and the status of each card. In a multishelf system, the Show command displays cards in all shelves of the system. You can also use the Show command for a particular slot card. For an example,
see “Viewing information about a particular slot card” on page 1-3.
The following example illustrates use of the Show command that displays a list of slot cards installed in the left controller, as well as lists primary status on the multishelf system: super->show
Controller { left-controller } ( PRIMARY ):
APX 8000/MAX TNT/DSLTNT Administration Guide 1-1
Administering Slot Cards
Viewing installed slot cards
{ shelf-1 slot-2 0 } UP csmx-card
{ shelf-1 slot-4 0 } UP hdlc2ec-card
{ shelf-1 slot-5 0 } UP madd2-card
{ shelf-1 slot-7 0 } UP oc3-atm-card
{ shelf-1 slot-8 0 } UP hdlc2ec-card
{ shelf-1 slot-9 0 } UP ether3-card
{ shelf-1 slot-11 0 } RESET 8e1-card
{ shelf-1 slot-12 0 } UP hdlc2-card
{ shelf-1 slot-13 0 } UP csmx-card
{ shelf-1 slot-14 0 } UP hdlc2-card
{ shelf-1 slot-15 0 } UP hdlc2ec-card
{ shelf-1 slot-16 0 } UP hdlc2ec-card
{ shelf-1 slot-17 0 } UP hdlc2ec-card
{ shelf-1 slot-19 0 } UP ether3-card
{ shelf-1 slot-20 0 } UP hdlc2-card
{ shelf-1 slot-21 0 } UP hdlc2-card
{ shelf-1 slot-22 0 } UP csmx-card
{ shelf-1 slot-23 0 } UP t3-card
{ shelf-1 slot-24 0 } UP hdlc2-card
{ shelf-1 slot-25 0 } UP hdlc2-card
{ shelf-1 slot-26 0 } UP csmx-card
{ shelf-1 slot-27 0 } UP hdlc2-card
{ shelf-1 slot-29 0 } UP ether3-card
{ shelf-1 slot-30 0 } UP csmx-card
{ shelf-1 slot-33 0 } UP t3-card
{ shelf-1 slot-34 0 } UP hdlc2ec-card
{ shelf-1 slot-36 0 } UP 8t1-card
{ shelf-1 slot-38 0 } UP ether3-card
{ shelf-1 slot-39 0 } UP ether3-card
The output lists the physical address of each slot in which a slot card is installed. The address is in the form {shelf slot item}. Each listing also shows the status of the card and the type of card installed.
The status can be reported as follows:
Status
UP
DOWN
POST
LOAD
Signifies
Normal operational mode.
Not in operational mode.
The card is running power-on self tests.
The card is loading code as part of booting up.
1-2 APX 8000/MAX TNT/DSLTNT Administration Guide
Administering Slot Cards
Viewing information about a particular slot card
Status
UP
OCCUPIED
RESET
NONE
Signifies
Normal operational mode.
The slot is occupied by a two-slot card (such as the
48 modem card in shelf 1, slots 3 and 4, in the example above).
The card is being reset.
The card has been swapped out, but its configuration remains in NVRAM.
The Show command can report the following types of slot cards:
Label
unknown
4/1ether-card
4ether-card
4ether2-card
48modem-card
48modem-56k-card
8e1-card
8t1-card csmx-card ds3-atm-card shelf-controller
Signifies
Current software does not recognize the card in the slot.
Ethernet card with one 100Mbps and four 10Mbps ports.
Ethernet card with four 10Mbps ports.
Ethernet card with one 100Mbps and three 10Mbps ports.
48 V.34 modem card.
Series56 Digital Modem card.
8-line E1 slot card.
8-line T1 slot card.
Series56 II Digital Modem card.
DS3 card with ATM support.
Shelf-controller card.
Viewing information about a particular slot card
To use the Show command for information about a particular command, add the shelf and slot-card numbers as arguments. For example: admin>show 1 3
Shelf 1 ( standalone ):
{ shelf-1 slot-3 0 } UP 4ether2-card:
{ shelf-1 slot-3 1 } UP ethernet-1
{ shelf-1 slot-3 2 } UP ethernet-2
{ shelf-1 slot-3 3 } UP ethernet-3
{ shelf-1 slot-3 4 } UP ethernet-4
{ shelf-1 slot-3 5 } 100-Base-T
Opening a session with a slot card
To open a session with a slot card, use the Open command as in the following example:
APX 8000/MAX TNT/DSLTNT Administration Guide 1-3
Administering Slot Cards
Changing a slot state
admin>
open 1 7
where 1 is the shelf number and 7 is the slot number.
On the master shelf of a multishelf system, you can open a session with a slave shelf. For example: admin> open 3 17
You cannot use the Open command from the slave shelf.
After you have established a session with the card, the prompt changes to indicate the type of card, its slot number, and its shelf number. To list the commands available on the card, enter a
?
or help , as in the following example: t1-1/1> ?
? ( user )
auth ( user )
cbcardif ( debug )
cbsnmptrap ( debug )
cbStats ( debug )
checkd ( debug )
clear ( user )
clock-source ( diagnostic )
debug ( diagnostic )
debugd ( debug )
display ( debug )
dp-decode ( debug )
dp-ram-display ( debug )
dpram-test ( debug )
dspBypassClients ( debug )
dspDial ( debug )
dspSetDddTimeslot ( debug )
fakeCalledId ( debug )
fakeClid ( debug )
fe-loop ( diagnostic )
fill ( debug )
frreset ( debug )
[More? <ret>=next entry, <sp>=next page, <^C>=abort]
For information about the card-level commands, see the APX 8000/MAX TNT/DSLTNT
Reference.
To exit the session with the card, enter quit
, as in the following example: t1-1/1>
quit
Changing a slot state
To force a change in the state of a slot, use the Slot command, as shown in the following examples.
To bring a slot down, use the Slot command with the
-d
option, and specify the shelf and slot number of the card you want to shut down. For example:
1-4 APX 8000/MAX TNT/DSLTNT Administration Guide
Administering Slot Cards
Changing a device state
admin>
slot -d 1 3
slot 1/3 state change forced
When you bring a card down with the Slot command, it only remains down until the next reboot.
To bring a slot up: admin>
slot -u 1 3
slot 1/3 state change forced
You cannot change the state of a slave shelf controller by using the Slot –u or Slot –d commands.
Changing a device state
To force a change in the state of a device, use the Device command, as shown in the following examples.
To bring a device down: admin>
device -d {{1 3 6} 24}
slot 1/3 state change forced
To bring a device back up: admin>
device -u {{1 3 6} 24}
slot 1/3 state change forced
Removing a slot card and its configuration
TAOS unit slot cards are hot swappable. When you remove a card, the system retains its configuration. This enables you to re-install the card or install another of the same type in the same slot, without reconfiguring the system or uploading a backup configuration. One side-effect of this feature is that the NVRAM used to store configuration information is not cleared when a card is removed, until you explicitly clear the configuration.
When a card has been removed, it shows up with a status of NONE in the Show command output. For example: admin> show 1 13
Shelf 1 ( master ):
{ shelf-1 slot-13 0 } NONE slot-card-8t1:
{ shelf-1 slot-13 1 } t1-line-1
{ shelf-1 slot-13 2 } t1-line-2
{ shelf-1 slot-13 3 } t1-line-3
{ shelf-1 slot-13 4 } t1-line-4
{ shelf-1 slot-13 5 } t1-line-5
{ shelf-1 slot-13 6 } t1-line-6
{ shelf-1 slot-13 7 } t1-line-7
{ shelf-1 slot-13 8 } t1-line-8
APX 8000/MAX TNT/DSLTNT Administration Guide 1-5
Administering Slot Cards
Viewing the clock source for a slot card
The NONE status indicates that the card was removed but its profiles have been saved. The
TAOS unit remembers that a card was in that slot and saves its profiles until a card of a different type is installed in the same slot, or until the administrator enters the Slot -r command, as in the following example: admin> slot -r 13 slot 1/13 removed
In either case, all the old profiles associated with the slot are deleted. If a different type of card is inserted, appropriate new profiles are created.
Viewing the clock source for a slot card
The Clock-Source command can be run on the shelf controller or on an individual card, as in the following example on a T1 card: admin>
open 1 1
t1-1>
clock-source
Master line: 3
Source List:
Source: line 3 Available* priority: 1
Sources with layer 2 up, which are preferred, are marked with an asterisk. For information about configuring the clock source see the hardware installation guide.
Recovering from a failed slot-card installation
If you installed a new slot card before upgrading the system software, and the slot card does not come up properly, there are two ways to recover:
• Use the NVRAM command.
• Remove the slot card.
Using the NVRAM command
!
Caution:
Using the NVRAM command resets the entire system. This method cannot be done remotely because the NVRAM command clears the TAOS unit’s configuration, including its
IP address. Before performing this procedure make sure you have access to the TAOS unit’s serial port.
To recover from a failed slot-card installation by this method:
1
Save the current system configuration. For example: admin>save network bonzo 971001
This saves the configuration to a file named 971001 in the TFTP home directory on a host named bonzo
.
2
Clear the system configuration and restart the TAOS unit by executing the NVRAM command:
1-6 APX 8000/MAX TNT/DSLTNT Administration Guide
Administering Slot Cards
Recovering from a failed slot-card installation
admin>nvramclear
3
Restore the saved system configuration.
You can either restore it through the serial port, or you can reassign an IP address and default gateway through the serial port, then use the Load command to load the rest of the configuration as in the following example: admin>load config network bonzo 971001
This restores the configuration from a file named 971001 in the TFTP home directory on a host named bonzo .
Removing the slot card
To recover from a failed slot-card installation by removing the slot card:
1
Save the current configuration of any profiles on the card. For example: admin>save network bonzo 971001 t1
This saves the configuration of all the T1 profiles to a file named 971001 in the TFTP home directory on a host named bonzo
.
2
Bring down the card, as in the following example: admin> slot -d 1 1
This disables the slot card in shelf 1, slot 1.
3
Remove the card profile: admin> slot -r 1 1
4
Bring the card back up: admin> slot -u 1 1
5
Restore the configuration of any profiles on the card. For the T1 card in this example, you would enter the following command: admin>load config network bonzo 971001
This restores the configuration from a file named 971001 in the TFTP home directory on a host named bonzo .
APX 8000/MAX TNT/DSLTNT Administration Guide 1-7
Administering Slot Cards
Displaying line status
Displaying line status
To display the activity of the TAOS unit’s WAN lines, enter the Line command: admin>
line
[
all
|
enabled
] [
top
|
bottom
] where
• all
displays all lines.
• enabled
displays enabled lines.
• top displays the status window at the top of the screen.
• bottom
displays the status window at the bottom of the screen.
Figure 1-1 shows an example of a line-status window for the T3 card.
Figure 1-1. Example of a T3 card line-status window
1 Connections, 1 Sessions |"my T3" 1/15/00 LA la la la la la la la
0065 FRM2-SLC MPP 09/02/1 56000| 1/15/01 LA T-------- -------- --------
| 1/15/02 LA T-------- -------- --------
| 1/15/03 LA T-------- -------- --------
| 1/15/04 LA T-------- -------- --------
| 1/15/05 LA T-------- -------- --------
| 1/15/06 LA T-------- -------- --------
| 1/15/07 LA T-------- -------- --------
|-----------------------------------------------
|M: 520 L: notice Src: shelf-1/slot-15
|
| Line 28 up
|
|
|
|
--------------------------------------------------------------------------------
[ Next/Last Line: <up/dn arw>, Next/Last Page: <pg up/dn>, Exit: <esc> ]
The first entry in the right-hand area of the screen shows the overall status of the DS3 line and each of its seven component DS2 channels. One DS2 includes 4 DS1s. The other entries represent each of the component DS1s.
The Line commands put the window in line-status mode, in which the following message appears below the status window:
[Next/Last Conn:<dn/up arw>, Next/Last Page:<pg dn/up>,Exit: <esc>]
The message indicates the key sequences you can use for displaying additional information in the line status area. The Down Arrow and Up Arrow keys display the next and previous T1 line in the list, respectively. The Page Down and Page Up keys display the list a screen at a time.
When the line-status mode message is displayed, the system prompt does not appear at the bottom of the window. Press the Escape key to exit this mode and return to the system prompt.
Line status information includes the following identifiers and codes:
1-8 APX 8000/MAX TNT/DSLTNT Administration Guide
Administering Slot Cards
Displaying line status
• Line identifier in shelf/slot/line format
• Two-character code indicating the line’s link status
• Single-character code indicating channel status
• Single-character code indicating channel type
Following are the link-status codes:
Code Description
LA
LS
LF
NT
(link active)
(UDS3 lines)
(UDS3 lines)
The line is active and physically connected
Loss of Signal. No signal has been detected.
Loss of Frame. A signal is present but is not valid for framing.
The E1 line is active and configured as network-side equipment.
TE
RA
(red alarm)
The E1 line is active and configured as user-side equipment.
The line is unconnected, improperly configured, experiencing a very high error rate, experiencing a loss-of-receive-signal, or is not supplying adequate synchronization.
YA
(yellow alarm) The TAOS unit is receiving a Yellow Alarm pattern, an indication that the other end of the line cannot recognize the signals the TAOS unit is transmitting.
The D channel for a PRI line is not currently communicating.
DF
(d-channel fail)
1S
(all ones) A keep-alive (also known as a Blue Alarm) signal is being sent from the PRI network to the TAOS unit to indicate that the line is currently inoperative.
ID
(idle—DS3 only) The DS3 interface has detected an Idle Signal transmitted from the other side. This generally indicates that the line is provisioned but is not in use.
WF
(wrong framing—DS3 only)
The DS3 interface has detected that the other side is using a framing format that differs from the one the local DS3 interface is configured for (C-bit-parity or M13).
Following are the channel-status codes:
Code:
.
(period)
* (asterisk)
- (hyphen) b
Description
The channel is not available because of one of the following reasons:
• Line is disabled
• Channel has no physical link
• Channel does not exist
• Channel configuration specifies that it is unused
• Channel is reserved for framing (first E1 channel only)
The channel is connected in a current call.
The channel is currently idle (but in service).
The channel is a backup NFAS D channel (T1 PRI only).
APX 8000/MAX TNT/DSLTNT Administration Guide 1-9
Administering Slot Cards
Displaying line status
Code
N
P
E
I
S
T
Description
E1 line
T1 PRI signaling
All other NFAS types
NFAS Primary
NFAS Secondary
T1 inband signaling
Additional option for displaying line status
The Line command can display line status on screen with paged output (the output is passed to a more
function before display) and supports the grep-like capability of searching for particular strings.
If you use the Line command without options, or with the all
, enabled
, top,
or bottom arguments, it opens the Line status window. With the
-p
option, the command displays the status information at the command line.
To use the Line command, you must have System permissions. The Line command supports the following syntax: admin> help line line usage: line [ [all | enabled ] [ top | bottom] ] | [ -p ]
Option
-p
Description
Print line status information to screen.
With the
-p
option, the Line command displays line status information directly to screen. For example, the following is sample output for T1 lines: admin> line -p
1-10 APX 8000/MAX TNT/DSLTNT Administration Guide
Administering Slot Cards
Administering DS3-ATM cards
Address Line State CARR LOOP DS0 Channel Status Signaling Type
1/01/01 ACTIVE -- LOOP ........ ........ ........ inband
1/01/02 RED ALARM LOC -- ........ ........ ........ r1-inband
1/01/03 ACTIVE -- -- -------- -------- -------- inband
1/01/04 RED ALARM -- -- ........ ........ ........ isdn-nfas
1/01/05 RED ALARM LOC -- ........ ........ ........ inband
1/01/06 DISABLED -- -- @@@@@@@@ @@@@@@@@ @@@@@@@@ inband
1/01/07 DISABLED -- -- @@@@@@@@ @@@@@@@@ @@@@@@@@ inband
1/01/08 DISABLED -- -- @@@@@@@@ @@@@@@@@ @@@@@@@@ inband
Following is sample output for E1 lines: admin> line -p
Address Line State CARR LOOP DS0 Channel Status Signaling Type
1/14/01 ACTIVE -- -- .------- -------- s------- e1-indian-signa
1/14/02 RED ALARM LOC -- ........ ........ ........ e1-dpnss-signal
1/14/03 ACTIVE -- -- .------- -------- s-------e1-indian-signa
1/14/04 DISABLED -- -- @@@@@@@@ @@@@@@@@ @@@@@@@@ @@@@@@@@
1/14/05 DISABLED -- -- @@@@@@@@ @@@@@@@@ @@@@@@@@ @@@@@@@@
1/14/06 DISABLED -- -- @@@@@@@@ @@@@@@@@ @@@@@@@@ @@@@@@@@
1/14/07 DISABLED -- -- @@@@@@@@ @@@@@@@@ @@@@@@@@ @@@@@@@@
1/14/08 DISABLED -- -- @@@@@@@@ @@@@@@@@ @@@@@@@@ @@@@@@@@
The command displays the following line status information:
Output field
Address
Line State
CARR
LOOP
DS0 Channel Status
Signaling Type
Description
Shelf/Slot/Line number of the line. This information was displayed in the Line window in previous releases, and is documented in the APX 8000/MAX TNT/DSLTNT Reference.
Status of the line. This information was displayed in the Line window in previous releases, and is documented in the APX
8000/MAX TNT/DSLTNT Reference. In addition, the LB line-state indicator has been added to indicate that an E1 line is looped back via the fe-loop
command on the E1 card.
(Carrier). If the system detects a loss of carrier on a line,
LOC
is displayed. If the line sees carrier, it displays dashes (
--
).
(Loopback status). If the line is locally looped,
LOOP
is displayed.
Otherwise, the column contains dashes (
--
).
State of the individual DS0 lines. This information was displayed in the Line window in previous releases, and is documented in the
APX 8000/MAX TNT/DSLTNT Reference.
The type of signaling in use on the line. This information was displayed in the Line window in previous releases, and is documented in the APX 8000/MAX TNT/DSLTNT Reference.
Administering DS3-ATM cards
The DS3ATM#lines, Framer, and ATMDumpCall commands allow you to perform diagnostics on the DS3-ATM card.
APX 8000/MAX TNT/DSLTNT Administration Guide 1-11
Administering Slot Cards
Administering DS3-ATM cards
Using the DS3ATMlines command
This command uses the following syntax: admin> ds3atmlines
-option
where
-
option
may be one of the following:
Option
-a
-d
-f
-u
Effect
Displays all available DS3-ATM lines.
Displays disabled DS3-ATM lines.
Displays free DS3-ATM lines.
Displays in-use DS3-ATM lines.
In the following example, the DS3-ATMlines command displays all DS3-ATM lines: admin> ds3atmlines -a
All DS3-ATM lines:
(dvOp dvUpSt dvRq sAdm nailg)
Line { 1 4 1 } (Up Idle UP UP 00000)
Regardless of which option you enter, the DS3-ATMlines command displays the following information:
Column Name
dvOp dvUpSt dvRq
SAdm nailg
Description
The operational state of the DS3 line. Values can be:
• Down
• Up
The up status of the DS3 line. Values can be:
• Idle
• Reserved
• Assigned
The required state of the DS3 line. Values can be:
• Down
• Up
The desired state of the device. Values can be:
• Down
• Up
The nailed group that this line is assigned to.
Using the Framer command
The Framer command is a low-level management tool for use during diagnostic sessions with the DS3-ATM card. For example, to use the Framer command on a DS3 card on shelf 1 in slot
3, first enter the Open command as follows:
1-12 APX 8000/MAX TNT/DSLTNT Administration Guide
Administering Slot Cards
Administering DS3-ATM cards
admin>
open 1 3
Then, enter the Framer command: ds3-atm-1/3>
framer -
option
where
-option
is one of the following:
Option
-t
-d
-l
-r
-s
-c
-?
Effect
Toggles debug output.
Dump ATM framer chip status information. The information this command displays is also available from the status lights on the card and in the DS3-ATM-Stat profile.
Toggle a local loopback.
Toggle a remote loopback.
Synchronize to the DS3-ATM profile. The TAOS unit automatically re-reads the line configuration whenever it comes up.
Clear the error counters.
Displays this summary.
For example, to view overall status information about the DS3-ATM line, enter the Framer command with the
-d
option: ds3-atm-1/4> framer -d
Framer is Enabled
RED_ALARM_LED : Off
YELLOW_ALARM_LED: Off
AIS_LED : Off
OOF_LED : Off
ACTIVE_LED : On
F-Bit Error Counter: 35
P-Bit Error Counter: 20
C-PBit Error Counter: 10
FEB Error Counter: 51
BPV Error Counter: 12
EZD Error Counter: 39
Following are the Framer command output fields with descriptions:
State
Red_Alarm_LED
Yellow_Alarm_LED
AIS_LED
OOF_LED
Description
On indicates the line is not connected, or it is improperly configured, experiencing a very high error rate, or supplying inadequate synchronization.
On indicates the card is receiving yellow-alarm from far end.
On indicates the card is receiving alarm indication signal
On indicates the near end is in an out of frame condition.
APX 8000/MAX TNT/DSLTNT Administration Guide 1-13
Administering Slot Cards
Administering DS3-ATM cards
State
Active_LED
Description
On indicates multipoint established.
The remaining parameters indicate the errors on the DS3 line. (Refer to RFC 1407 for complete description of these errors.)
Parameter
F Bit Error Counter
P Bit Error Counter
CP Bit Error Counter
FEB Error Counter
BPV Error Count
EZD Error Counter
Description
Framing bit errors received since the last TAOS unit’s reset or the error counters were cleared.
P-bit errors indicate that TAOS unit received a P-bit code on the DS3 M-frame that differs from the locally calculated code.
For C-Bit-Parity lines indicates that number of parity errors since the last TAOS unit’s reset.
Far end block errors received since the last TAOS unit’s reset.
Bipolar Violation (BPV) errors may indicate that the line sent consecutive one bits with the same polarity. It could also mean that three or more consecutive zeroes were sent or an incorrect polarity.
Number of Excessive Zero Detect (EZD) line code violations that have occurred since the error counters were cleared.
Using the ATMDumpCall command
The ATMDumpCall command is a low-level management tool for use during diagnostic sessions with the DS3-ATM card. It allows you to view the ATM call blocks, which contain information about outgoing calls.
For example, to manage a DS3 card on the shelf 1 in slot 3, first enter the Open command as follows: admin> open 1 3
Then, enter the ATMDumpCall command: ds3-atm-1/3> atmdumpcall -option where
-option
is one of the following:
Option
-a
-l
-u
Effect
Display all ATM call blocks, even those that are inactive.
Display DS3-ATM line configuration information.
Display in-use ATM call blocks.
For example, to view all ATM call blocks, enter the ATMDumpCall command with the
-a option:
1-14 APX 8000/MAX TNT/DSLTNT Administration Guide
Administering Slot Cards
Administering DS3-ATM cards
ds3-atm-1/3>
atmdumpcall -a
atmdumpcall -a
ATM Call Block Table:
Addr. Index Active callID routeID State Vpi/Vci Prof_Name Sess_Up
E00C47F0 0 1 1 1 CONNECTED 1/43 atm-30-sw Yes
E00C4834 1 1 2 2 CONNECTED 15/1023 Yossi-TNT Yes
E00C4878 2 1 3 3 CONNECTED 1/56 Yoss-P220 Yes
E00C48BC 3 0 65535 0 INACTIVE 0/0 - No
E00C4900 4 0 65535 0 INACTIVE 0/0 - No
.
.
.
E00C5868 62 0 65535 0 INACTIVE 0/0 - No
E00C58AC 63 0 65535 0 INACTIVE 0/0 - No
ATM Free Blocks: 360
ATM Used Blocks: 0
Using the OAMLoop command
The OAMLoop command sends ATM Operation-And-Maintenance (OAM) loop-back cells on an ATM interface, to obtain information about the results of the looped cells. It uses the following syntax: admin> oamloop -option where option is one of the following:
Option
-e
-s
–c count
–i sec
shelf slot vpi
Description
(End-to-End). Transmit an end-to-end OAM loop cell, to be looped by the user connection point. This option and the
-s option are mutually exclusive, and one of them must be specified on the command line.
(Segment). Transmit a segment OAM loop cell, to be looped by the first network connection point. This option and the
-e
option are mutually exclusive, and one of them must be specified on the command line.
Transmit the specified number of cells. If this argument is not specified, the count defaults to 0, which means that the cells are transmitted continuously until the administrator sends an interrupt by pressing Ctrl-C.
Transmit the cells at the specified interval in seconds. If this argument is not specified, the interval defaults to one second.
Specifies the shelf in which the DS3-ATM card is located.
Specifies the slot in which the DS3-ATM card is located.
Specifies the Virtual Path Identifier on which to transmit the looped-back cells.
APX 8000/MAX TNT/DSLTNT Administration Guide 1-15
Administering Slot Cards
Administering Ethernet cards
Option
vci
Description
Specifies the Virtual Channel Identifier on which to send the looped-back cells.
Following is an example OAMloop command line and output: admin> oamloop -c 10 -e 1 2 1 32
Received our End2End OAM loopback cell, Id=9
Received our End2End OAM loopback cell, Id=10
Received our End2End OAM loopback cell, Id=11
Received our End2End OAM loopback cell, Id=12
Received our End2End OAM loopback cell, Id=13
Received our End2End OAM loopback cell, Id=14
Received our End2End OAM loopback cell, Id=15
Received our End2End OAM loopback cell, Id=16
Received our End2End OAM loopback cell, Id=17
Received our End2End OAM loopback cell, Id=18
--- OAM loop statistics ---
10 cells transmitted, 10 cells received, 0% cell loss
Looping back the DS3-ATM line
For diagnostics, you might want to loopback the DS3 interface by using the Loopback parameter in the DS3-ATM profile. While the interface is looped back, normal data traffic is interrupted. The Loopback parameter in the DS3-ATM profile supports the following settings:
• No-Loopback. The default, specifies that the DS3 line is operating normally.
• Facility-Loopback. During a facility loopback, the DS3 card returns the signal it receives on the DS3 line.
• Local-Loopback. During a local loopback, the DS3 receive path is connected to the DS3 transmit path at the D3 multiplexer. The transmitted DS3 signal is still sent to the network as well.
Line statistics are displayed in the DS3-ATM-Stat profile. For information about this profile,
see “Using DS3-ATM-Stat profiles” on page 7-9.
To configure a loopback, proceed as in the following example:
1
Read the DS3-ATM profile: admin> read ds3-atm {1 3 1}
DS3-ATM/{ shelf-1 slot-3 1 } read
2
Activate the loopback: admin> set line loopback= [facility-loopback|local-loopback]
3
To end the loopback, set the Loopback parameter to No-Loopback: admin> set line loopback = no-loopback
Administering Ethernet cards
For all Ethernet interfaces except the shelf controller, the TAOS unit detects and flags changes in the interface link-state. You can enable a feature in the Ethernet profile that causes automatic
1-16 APX 8000/MAX TNT/DSLTNT Administration Guide
Administering Slot Cards
Administering Ethernet cards
routing table updates based on physical link-state changes. Routes to a disabled (down) interface are deleted from the IP routing table, so alternative configured routes can be used instead, and the routes are added again when the interface comes back up. You can also choose to administratively shut down a LAN interface by disabling its Ethernet profile.
The following parameters, shown with their default settings, are related to LAN-interface link-state changes:
ETHERNET {shelf-N slot-N item-N}
enabled = yes
link-state = up
link-state-enabled = no
For information about configuring a management-only Ethernet interface, see the hardware installation guide for your unit.
Enabling or disabling an Ethernet interface
The Enabled parameter in an Ethernet profile specifies whether a LAN interface is enabled (the default) or disabled. If Enabled is set to No, packets routed to and received on the interface are discarded. Note that the user-specified state is preserved across system resets.
An interface may also be disabled by using the Ifmgr command, or it may be marked as down by the Ethernet driver when Link-State-Enabled is Yes and Link-State is Down.
To enable an interface, set the Enabled parameter to Yes (the default), or use the Ifmgr Up option. Note, however, that if there are physical problems with the interface, specifying the interface as up might not enable it.
To disable an interface with the Ifmgr command, proceed as in the following example:
1
Open a session with an Ethernet card: admin> open 1 4 ether-1/4> ifmgr
2
View the interface table: ether-1/4> ifmgr -d if slot:if u p ifname mac addr local-addr
--------------------------------------------------------------
000 0:00:000 * pb0 000000000000 0.0.0.0/32
001 1:17:011 * ie1-4-1 00c07b6d23f0 11.1.1.1/32
002 1:17:013 * ie1-4-2 00c07b6d23f1 11.1.2.1/32
003 1:17:015 * ie1-4-3 00c07b6d23f2 11.1.3.1/32
004 1:17:017 * ie1-4-4 00c07b6d23f3 11.1.4.1/32
005 1:17:019 * ie1-4-5 00c07b6d23f4 11.1.5.1/32
<end>
3
Mark the interface as down by specifying its name: ether-1/4> ifmgr down ie1-4-1
The Ifmgr display indicates that the interface is disabled by displaying a dash instead of an asterisk in the Up column ( u ): ether-1/4> ifmgr -d if slot:if u p ifname mac addr local-add
------------------------------------------------------------------
000 0:00:000 * pb0 000000000000 0.0.0.0/32
APX 8000/MAX TNT/DSLTNT Administration Guide 1-17
Administering Slot Cards
Administering Ethernet cards
001 1:17:011 - ie1-4-1 00c07b6d23f0 0.0.0.0/32
002 1:17:013 * ie1-4-2 00c07b6d23f1 11.1.2.1/32
003 1:17:015 * ie1-4-3 00c07b6d23f2 11.1.3.1/32
004 1:17:017 * ie1-4-4 00c07b6d23f3 11.1.4.1/32
005 1:17:019 * ie1-4-5 00c07b6d23f4 11.1.5.1/32
<end>
Note:
A disabled Ethernet interface is also shown with a dash in Netstat command output.
To mark an interface as up, enter a command similar to the following: ether-1/4> ifmgr up ie1-4-1
For more information about the Ifmgr command, see “IFMgr” on page 4-16.
Specifying how the link state affects the IP routing table
The Link-State-Enabled parameter signifies whether the value of the Link-State parameter affects the IP routing tables. If it is set to Yes, routes to an interface are deleted when the link state is down, and added back when the interface comes back up again. If the parameter is set to No (the default), packets are routed to the interface regardless of its link-state. If the interface is down, packets are discarded rather than transmitted over using an alternative route.
A read-only indication of physical link-state
The Link-State parameter shows the physical state of the LAN interface: up or down. The parameter can only be set by the Ethernet driver. A LAN interface is down if it cannot transmit or receive network traffic (for example, if the Ethernet cable is unplugged or the Ethernet hub on that interface is down). For the shelf-controller Ethernet interface, the value of the
Link-State parameter is set to Unknown.
Checking multiple IP interfaces on an Ethernet port
In the following Ifmgr command output, the physical interface 1-12-1 has two IP-Interface profiles associated with it. The first is named ie1-12-1
(the default profile), and the second is named ie1-12-1-1 : admin> ifmgr -d bif slot sif u m p ifname host-name remote-addr local-addr
---------------------------------------------------------------------------
000 1:17 000 * ie0 - 0.0.0.0/32 200.168.6.188/32
001 1:17 001 * lo0 - 0.0.0.0/32 128.0.0.1/32
002 0:00 000 * rj0 - 0.0.0.0/32 128.0.0.2/32
003 0:00 000 * bh0 - 0.0.0.0/32 128.0.0.3/32
004 0:00 000 * local - 0.0.0.0/32 128.0.0.1/32
005 0:00 000 * mcast - 0.0.0.0/32 225.0.0.0/32
006 1:12 001 * ie1-12-1 - 0.0.0.0/32 10.5.6.7/32
007 1:12 002 * ie1-12-2 - 0.0.0.0/32 0.0.0.0/32
008 1:12 003 * ie1-12-3 - 0.0.0.0/32 0.0.0.0/32
009 1:12 004 * ie1-12-4 - 0.0.0.0/32 0.0.0.0/32
010 1:12 005 * ie1-12-1-1 - 0.0.0.0/32 10.9.1.212./24
1-18 APX 8000/MAX TNT/DSLTNT Administration Guide
Administering Slot Cards
Administering T1 and T3 cards
Administering T1 and T3 cards
TAOS unit T1and T3 cards are all administered in much the same way. In most cases,
administration of the individual T1 lines on the three cards is identical. Table 1-1 briefly
describes the different methods you can use to manage the T1 and T3 cards and show where each method is discussed in this manual.
Table 1-1. T1-line maintenance tasks
Task/section of this manual Description Associated parameter or command
“Quiescing a PRI line or T1 channels” on page 1-19.
Quiescing a PRI line allows you to gradually take a line or channels out of service.
Maintenance-State parameter
Quiesce command
“Specifying FDL” on page 1-20.
Your T1 service provider can use Facilities
Data Link (FDL) to monitor the status of your line.
FDL parameter
T1channel command
“Checking the status of T1 channels” on page 1-21.
“The FE-Loop command” on page 1-23.
Display the administrative state and nailed-group assignment of the T1 channels.
“Displaying DS1-level diagnostics for T1 cards” on page 1-22.
Display T1 channel errors.
Loopback the T1 line.
T1-Stats command
FE-Loop
Quiescing a PRI line or T1 channels
Quiescing a PRI line takes the line out of service by removing channels from service as active calls disconnect. The switch used by the carrier affects whether the line is taken out of service or busied out. For details, see the Quiesce command description in the APX 8000/MAX
TNT/DSLTNT Reference.
You can quiesce a line by using either of the following methods:
• Maintenance-State parameter in the T1 profile
• Quiesce command
Restoring a line or channel that has been quiesced can take up to 10 minutes.
Using the Maintenance-State parameter
To quiesce a line with the Maintenance-State parameter, proceed as in the following example: admin> set line maintenance-state=yes admin> write
T1/{ shelf-1 slot-2 1 } written
APX 8000/MAX TNT/DSLTNT Administration Guide 1-19
Administering Slot Cards
Administering T1 and T3 cards
Using the Quiesce command
You can enter the Quiesce command to quiesce a PRI line, port, or channel. The command uses the following syntax: admin>
quiesce -d
|
e
|
r
|
q
|
t
line
where
• -d quiesces a single DS0 channel.
•
-e
restores a quiesced DS0 channel.
• -r line restores the quiesced line.
• -q line quiesces a PRI line.
•
-t
toggles the diagnostic display.
For example, to quiesce a T1 PRI line at port 4 of a card installed in slot 2: admin>
quiesce -q {1 2 4}
QUIESCE: line 1/2/4, enable=T, isPri=T
Restoring a line or channel that has been quiesced can take up to 3.5 minutes, because only 1 service message per channel is sent to the switch, at a rate of one per second.
To restore the line quiesced in the preceding example: admin>
quiesce -r {1 2 4}
QUIESCE: line 1/2/4, enable=T, isPri=T
Following is an example of quiescing a single channel: admin>
quiesce -d {{1 2 4} 1}
Specifying FDL
The facilities data link (FDL) is used by the telephone company to monitor the quality and performance of T1 lines. If your carrier’s maintenance devices require regular data-link reports, and if the line is not configured for D4 framing, you can specify the type of protocol to use (AT&T, ANSI, or Sprint).
You cannot use FDL reporting on a line configured for D4 framing. However, you can obtain
D4 and ESF performance statistics in the FDL Stats windows or the DSX MIB, even if you do not choose an FDL protocol. (For further information, see the Frame-Type parameter description in the APX 8000/MAX TNT/DSLTNT Reference).
Note:
DS3-level FDL capabilities such as the Far-End Alarm and Control Channel (FEAC) and Path Maintenance Data Link are currently unsupported.
To specify the type of FDL, proceed as in the following example: admin> read t1 {1 2 1}
T1/{ shelf-1 slot-2 1 } read admin> set fdl = [none|at&t|ansi|sprint] admin> write
1-20 APX 8000/MAX TNT/DSLTNT Administration Guide
Administering Slot Cards
Administering T1 and T3 cards
Checking the status of T1 channels
To show T1-channel information, enter the T1Channels command. Use the following syntax: admin>
t1channels - a
|
d
|
c
|
i
where
•
-a
displays all available channels.
•
-d
displays the disabled channels.
•
-c
displays all possible channels.
•
-i
displays in-use channels.
For example, to display all T1 channels available, use the -a option: admin> t1channels -a
T1 channels available for use:
(dvOp dvUpSt dvRq sAdm nailg)
Channel { { 1 1 3 } 1 } (Up Idle UP UP
00000)
Channel { { 1 1 3 } 2 } (Up Idle UP UP
00000)
Channel { { 1 1 3 } 3 } (Up Idle UP UP
00000)
Channel { { 1 1 3 } 4 } (Up Idle UP UP
00000)
Channel { { 1 1 3 } 5 } (Up Idle UP UP
00000)
Channel { { 1 1 3 } 6 } (Up Idle UP UP
00000)
Channel { { 1 1 3 } 7 } (Up Idle UP UP
00000)
Channel { { 1 1 3 } 8 } (Up Idle UP UP
00000)
Channel { { 1 1 3 } 9 } (Up Idle UP UP
00000)
Channel { { 1 1 3 } 10 } (Up Idle UP UP
00000)
Channel { { 1 1 3 } 11 } (Up Idle UP UP
00000)
Channel { { 1 1 3 } 12 } (Up Idle UP UP
00000)
To display information about which T1 channels are in use: admin> t1channels -i
T1 channels allocated/in-use:
(dvOp dvUpSt dvRq sAdm nailg)
Channel { { 1 1 1 } 1 } (Up Assign UP UP 00000) I
Channel { { 1 1 1 } 9 } (Up Assign UP UP 00006) I
Channel { { 1 1 1 } 10 } (Up Assign UP UP 00006) I
Channel { { 1 1 1 } 11 } (Up Assign UP UP 00006) I
APX 8000/MAX TNT/DSLTNT Administration Guide 1-21
Administering Slot Cards
Administering T1 and T3 cards
Channel { { 1 1 1 } 12 } (Up Assign UP UP 00006) I
Channel { { 1 1 1 } 13 } (Up Assign UP UP 00006) I
Channel { { 1 1 1 } 14 } (Up Assign UP UP 00006) I
Channel { { 1 1 1 } 15 } (Up Assign UP UP 00006) I
Channel { { 1 1 1 } 16 } (Up Assign UP UP 00006) I
Channel { { 1 10 10 } 1 } (Up Assign UP UP 00005) I
Displaying DS1-level diagnostics for T1 cards
The T1-Stats command reports DS1-level line errors. Before entering the command, use the
Open command to open a session with the installed card. For example, to open a session with a card in shelf 1, slot 13: admin>
open 1 13
Then enter the T1-Stats command. The following example shows the command’s syntax: t1-1/13>
t1-stats
t1-stats [ -c ] <line> get error statistics for the line
-c: reset statistics to zero
To view DS1-level statistics on the first line on the card: t1-1/13>
t1-stats 1
Line 1:
CRC Errors: 0
Frame Slips: 8
Framing Bit Errors: 0
Out of Frame Events: 0
Line Code Violations: 0
Table 1-2 explains the T1-Stats fields.
Table 1-2. T1-Stats command fields
Field
CRC Errors
Frame Slips
Framing Bit Errors
Out of Frame Events
Event that increments the field
Indicates that a CRC-6 checksum shows data corruption in the signal.
The TAOS unit receives T1 data at a frequency higher or lower than the internal line clock. In the process of realigning itself to the transmitter, the TAOS unit can skip or repeat a frame.
Framing bit errors occur when the TAOS unit receives T1 data at a frequency higher or lower than that of the internal line clock. In the process of realigning itself to the transmitter, the
TAOS unit can skip or repeat a frame.
The TAOS unit no longer detects a framing pattern in the receiving signal, or it detects a pattern at a different relative offset than expected.
1-22 APX 8000/MAX TNT/DSLTNT Administration Guide
Administering Slot Cards
Administering T1 and T3 cards
Table 1-2. T1-Stats command fields (continued)
Field
Line Code Violations
Event that increments the field
The TAOS unit detected either a Bipolar Violation or Excessive
Zeros, which means that one of the low-level T1 rules for encoding data was violated in the received signal.
The following example shows how to view and reset the statistics to zero on line 2: t1-1/13>
t1-stats -c 2
Line 2:
CRC Errors: 2
Frame Slips: 3
Framing Bit Errors: 0
Out of Frame Events: 0
Line Code Violations: 3
Statistics cleared.
The Statistics cleared message at the end of the display indicates that the statistics have been reset to 0 (zero), because the command included the –c option.
The FE-Loop command
When a T1 line is looped back to the network, either as a result of the FE-Loop diagnostic command issued from the T1 card command line interface or as a result of loopback requests received from the network, the T1 line status display on the shelf controller shows the
LB
(loopback) status for the line.
The following examples demonstrate the use of the FE-Loop command:
To verify that the hardware is functioning properly, perform a local loopback by using the
FE-Loop command with the in option. For example, to internally loop back the first DS1 in slot 1: admin>
open 1 1
t1-1/1> t1-1/1>
fe-loop 1 in on
You can use this command when the line is in RA state. After looping back the line internally, state should change to LA. Note that the T3 card does not support the FE-Loop in
option.
To turn the internal loopback off: t1-1/1>
fe-loop 1 in off
To cause the unit to transmit the received signal back towards the network, enter the following command: t1-1/1>
fe-loop 1 out on
The receive side of the T1 is not bridged to the APX 8000. This command can be useful in testing the path to the TAOS unit by:
• Verifying that the switch can synchronize to its own returned signal.
APX 8000/MAX TNT/DSLTNT Administration Guide 1-23
Administering Slot Cards
Administering T1 and T3 cards
• Supporting test equipment that sends out a test pattern, such as a Quasi-Random Signal
(QRS), and verifying that the pattern is received unmodified.
To turn the remote loopback off: t1-1/1>
fe-loop 1 out off
Using DS3 diagnostics
The DS3Link command is a low-level management tool for use during diagnostic sessions with the T3 card. To open a session with the installed DS3 card, use the Open command.
For example, to manage a DS3 card on shelf 1 in slot 15, first enter the Open command as follows: admin>
open 1 15
Then, enter the DS3Link command: t3-1/15>
ds3link -
option
where
-option
is one of the following:
Option
-s
-t
-?
-a
-b on
-b off
-c
-d 1 - 7
-i on
-i off
-l on
-l off
Effect
Displays current DS3 line alarms.
Transmits a DS3 Alarm Indication Signal (Blue Alarm).
Stops transmitting a DS3 Alarm Indication Signal (Blue Alarm).
Displays and clears line error statistics.
Displays current DS2 line state.
Internally loops back the DS3 payload.
Halt internal loop back.
Externally loops back the DS3 payload.
Halt external loop back.
Displays line error statistics without clearing.
Toggles debug output.
Displays this summary.
To display alarms on the line: t3-15> ds3link -a
Loss of Signal: false
Out of Frame: false
Alarm Indication Signal: false
Idle Signal: false
Yellow Signal: false
In Red Alarm: false
C-bit parity framing: false
1-24 APX 8000/MAX TNT/DSLTNT Administration Guide
Administering Slot Cards
Administering T1 and T3 cards
A display of true
for C-bit parity framing would not indicate an alarm state, but that the far end is using C-bit parity.
To display and clear line error statistics: t3-1/15> ds3link -c
Line Code Violations: 2136611
Framing Errors: 67279
Excessive Zeros: 2098353
P-bit Parity Errors: 217318
C-bit Parity Errors: 0
Far End Block Errors: 0
DS2 1 Framing Errors: 8415
DS2 2 Framing Errors: 8415
DS2 3 Framing Errors: 8415
DS2 4 Framing Errors: 8415
DS2 5 Framing Errors: 8415
DS2 6 Framing Errors: 8415
DS2 7 Framing Errors: 8415
Statistics cleared.
To display the line state of the third DS2: t3-1/15> ds3link -d 3
State of DS2 3:
Out of Frame: false
Alarm Indication Signal: false
Yellow Signal: false
In Red Alarm: false
Reserved Bit: false
Performing an external loopback
To perform an external loopback test, use the -l option as follows: t3-1/15>
ds3link -l on
DS3 remote loopback activated t3-1/15>
ds3link -l off
DS3 remote loopback deactivated
Performing an internal loopback
An internal DS3 loopback connects the DS3 receive path to the DS3 transmit path at the D3.
The transmitted DS3 signal is still sent to the network.
To perform an internal loopback test, use the -i option as follows: t3-1/15> ds3link -i on
DS3 internal loopback activated
APX 8000/MAX TNT/DSLTNT Administration Guide 1-25
Administering Slot Cards
Administering E1 cards
t3-1/15> ds3link -i off
DS3 internal loopback deactivated
Note:
DS1 external loopbacks can be invoked manually with the FE-Loop command on the
DS3 card. In addition, you can display DS1 error statistics with the T1-Stats command. To use these commands, first use the Open command to open a session with the card, as described at the beginning of this section.
Administering E1 cards
The E1-Stats command reports DS1-level line errors on E1 cards. Before entering it, use the
Open command to open a session with the installed card. For example, to open a session with a card in shelf 1, slot 13: admin>
open 1 13
Then enter the E1-stats command. The following example shows the command’s syntax: e1-1/13> e1-stats e1-stats [ -c ] <line> get error statistics for the line
-c: reset statistics to zero
To view DS1-level statistics on the first line on the card: e1-1/13> e1-stats 1
DS1 Line 1:
CRC Errors: 0
Frame Slips: 9872
Framing Bit Errors: 0
Far End Block Errors: 0
Line Code Violations: 0
Statistics cleared.
To view and reset the statistics to 0 (zero) on line 2: e1-1/13> e1-stats -c 2
Line 2:
CRC Errors: 0
Frame Slips: 9872
Framing Bit Errors: 0
Far End Block Errors: 0
Line Code Violations: 0
Statistics cleared.
The
Statistics cleared
message at the end of the display indicates that the statistics have been reset to 0 (zero), because the command included the
–c
the E1-Stats fields.
Table 1-3. E1-Stats command fields
Field
CRC Errors
Event that increments the field
A CRC-6 checksum shows data corruption in the signal.
1-26 APX 8000/MAX TNT/DSLTNT Administration Guide
Administering Slot Cards
Administering UDS3 cards
Table 1-3. E1-Stats command fields (continued)
Field Event that increments the field
Frame Slips
Framing Bit Errors
The TAOS unit receives E1 data at a frequency higher or lower than the internal line clock. In the process of realigning itself to the transmitter, the TAOS unit can skip or repeat a frame.
Framing bit errors occur when the TAOS unit receives E1 data at a frequency higher or lower than that of the internal line clock. In the process of realigning itself to the transmitter, the TAOS unit can skip or repeat a frame.
Out of Frame Events The TAOS unit no longer detects a framing pattern in the receiving signal, or it detects a pattern at a different relative offset than expected.
Line Code Violations The TAOS unit detected either a Bipolar Violation or Excessive
Zeros, which means that one of the low-level E1 rules for encoding data was violated in the received signal.
Far end block errors The far end reported an error in an E1 frame transmitted by the
TAOS unit.
Administering UDS3 cards
The UDS3lines and UDS3dump commands enable you to monitor the UDS3 card.
Using the UDS3lines command
This command uses the following syntax: admin> uds3lines -option where
-option
may be one of the following:
Option
-a
-d
-f
-u
Effect
Displays all available UDS3 lines.
Displays disabled UDS3 lines.
Displays free UDS3 lines.
Displays in-use UDS3 lines.
In the following example, the UDS3lines command displays the all UDS3 lines: admin> uds3lines -a
All UDS3 lines:
(dvOp dvUpSt dvRq sAdm nailg)
Line { 1 13 1 } (Up Idle UP UP 00131)
APX 8000/MAX TNT/DSLTNT Administration Guide 1-27
Administering Slot Cards
Administering UDS3 cards
Regardless of which option you enter, the UDS3lines command displays the following information:
Column Name
dvOp dvUpSt dvRq
SAdm nailg
Description
The operational state of the UDS3 line. Values can be:
• Down
• Up
The up status of the UDS3 line. Values can be:
• Idle
• Reserved
• Assigned
The required state of the UDS3 line. Values can be:
• Down
• Up
The desired state of the device. Values can be:
• Down
• Up
The nailed group that this line is assigned to.
Using the UDS3Dump command
The UDS3dump card-level command displays the information about the DS3 interface. To use this command, first open a session to the UDS3 card, then issue the UDS3dump command, using the following syntax: uds3-1/11> uds3dump interval where
interval
may be one of the following:
Option
0
1-96
97
Effect
Displays the DS3 MIB (RFC 1407) dsx3CurrentTable.
Displays the DS3 MIB (RFC 1407) dsx3IntervalTable.
Displays the DS3 MIB (RFC 1407) dsx3TotalTable.
In the following example, the UDS3dump command displays the current interval table: uds3-1/13> uds3dump 0
Index PESs PSESs SEFSs UASs LCVs PCVs LESs CCVs CESs CSESs
---------------------------------------------------------------
0 0 0 0 1 0 0 0 0 0 0
1-28 APX 8000/MAX TNT/DSLTNT Administration Guide
Administering Slot Cards
Administering UDS3 cards
The output contains the following fields (refer to RFC 1407 for complete description of these errors):
Field
PESs
PSESs
SEFSs
UASs
LCVs
PCVs
LESs
CCVs
CESs
Description
A P-bit errored second is a second during which one of the following error conditions occurs:
• A P-Bit error
• An out of frame error
• An incoming A1S signal
Note that the count is not incremented by the number of unavailable seconds.
A P-bit severely errored second is a second during which one of the following error conditions occurs:
• There are 44 or more P-Bit errors
• An out of frame error
• An incoming A1S signal
Note that the count is not incremented by the number of unavailable seconds.
A severely errored framing second is a second during which one of the following error conditions occurs:
• An out of frame error
• An incoming A1S signal
The number of seconds the interface is unavailable. Note that only LES and SEFS errors are counted while the interface is unavailable.
A line coding violation error is the sum of bipolar (BPV) and excessive zero (EXZ) errors. An excessive zero error increments the count by one no matter how many zeros are transmitted.
P-bit errors indicate that TAOS unit received a P-bit code on the DS3
M-frame that differs from the locally calculated code.
A line errored seconds is a second during which one of the following error conditions occurs:
• A C-bit coding violation error
• A loss of signal error
A C-bit coding violation error indicates a parity error.
A C-bit errored second is a second during which one of the following error conditions occurs:
• A C-bit coding violation error
• An out of frame error
• An incoming A1S signal
This applies only to SYNTRAN and C-bit Parity DS3 lines. Note that the count is not incremented by the number of unavailable seconds.
APX 8000/MAX TNT/DSLTNT Administration Guide 1-29
Administering Slot Cards
Administering modems
Field
CSESs
Description
A C-bit severely errored second is a second during which one of the following error conditions occurs:
• There are 44 or more C-bit coding violation errors
• An out of frame error
• An incoming A1S signal
This applies only to SYNTRAN and C-bit Parity DS3 lines. Note that the count is not incremented by the number of unavailable seconds.
Administering modems
The TAOS unit provides diagnostic commands to display modem status, bring modems or channels up or down, or quiesce modems.
Using the Modem command to display modem status
To show modem information, enter the Modem command:
modem
-
a
|-
d
|-
f
|-
g
|-
i
|-
m
|-
s
where
• -a Displays all available modems.
•
-d
Displays the disabled channels.
• -f Displays failed or non-existent modems.
• -g Displays available good modems.
•
-i
Displays in-use modems.
• -m Displays all possible modems.
• -s Displays suspect modems.
For example, to see which modems are in use: admin>
modem -i
Modems allocated/in-use
Modem {1 14 1}
(dv0p dvUpSt DvRq sAdm)
(Up Assign UP UP )
For more information about the Modem command refer to the APX 8000/MAX TNT/DSLTNT
Reference.
Bringing a modem or channel up or down
To administratively up or down a device, you can use the Device command or a Device-State
For example, to administratively down modem 24 in slot 3 on shelf 1:
1-30 APX 8000/MAX TNT/DSLTNT Administration Guide
Administering Slot Cards
Administering modems
admin>
device -d {{1 3 24} 0}
To bring the modem back up: admin>
device -u {{1 3 24} 0}
Disabling a modem
To disable a modem:
1
Read in the LAN Modem profile. For example: admin>
read LAN-Modem
LAN-MODEM/{ shelf-1 slot-2 0 } read
2
Disable the modem: admin>
set modem-disable-mode 1= disable
3
Write the profile to commit your changes: admin>
write
LAN-MODEM/{ shelf-1 slot-2 0 } written
Quiescing digital modems
The system creates a LAN-Modem profile for each installed modem card. Removing or downing a modem card does not delete this profile or change its contents. You can use the
LAN-Modem profile to quiesce digital modems. Quiescing a modem makes it available for maintenance in a graceful way, not by tearing down the current connection, but by taking the channel out of service as soon as the connection is dropped.
To use a LAN-Modem profile, first open it and list its contents. For example: admin>
read lan {1 6 0}
LAN-MODEM/{ shelf-1 slot-6 0 } read admin>
list
physical-address* = { shelf-1 slot-6 0 } modem-disable-mode = [ enable enable enable enable enable +
Then, to quiesce a modem, list its Modem-Disable-Mode setting and change it to disable
.
For example: admin>
list modem-dis
...(All 48 modem settings are displayed) admin>
list 20
admin>
set = disable
admin>
write
LAN-MODEM/{ shelf-1 slot-6 0 } written
To bring the modem back up: admin> set = enable
APX 8000/MAX TNT/DSLTNT Administration Guide 1-31
Administering Slot Cards
Administering modems
admin> write
LAN-MODEM/{ shelf-1 slot-6 0 } written
Note:
When you quiesce a modem, you can also quiesce an arbitrary idle T1 channel at the same time by using the Dis-Channel setting. For details, see the APX 8000/MAX TNT/DSLTNT
Reference.
1-32 APX 8000/MAX TNT/DSLTNT Administration Guide
TAOS System Administration
2
APX 8000/MAX TNT/DSLTNT Administration Guide 2-1
TAOS System Administration
Logging into the TAOS unit
This chapter explains how to perform common system administration tasks on your TAOS unit. It focuses on tasks you can perform on the system as a whole, such as resetting the unit, setting the time and date, configuring logging, and backing up and restoring a configuration.
For information about managing the TAOS slot cards, see Chapter 1, “Administering Slot
Logging into the TAOS unit
To administer the system, you can log in from a PC connected to the TAOS unit’s serial port, or from a workstation that has Telnet access to the system. When you log in, you are prompted for a user name:
User:
To log in with administrative (superuser) privileges, enter the default password (
Lucent
) assigned to the TAOS unit Admin login at the factory:
User: admin
Password: Ascend
The name specified in the Admin User profile appears as your system prompt. For example: admin>
If you are already connected to the TAOS unit as a different user, use the Auth command to log in as the administrator: admin> auth admin
Password:
Note:
Because the Admin login has superuser privileges, you should change the default password immediately. Be sure to write down the password you assign and store it in a safe place.
Following is an example of changing the password for the Admin login: admin> read user admin
USER/admin read admin> set password = top-secret admin> write
USER/admin written
All subsequent administrator logins will be required to supply the new password. (For more
information about configuring User profiles, see Chapter 5, “Creating User Profiles.”)
Securing the serial port
By default, when users connect to the serial port on the shelf controller, they are logged in with the Admin User profile. To secure the serial port with a username and password, proceed as follows:
1
Read the Serial profile: admin>read serial { 1 17 2}
2-2 APX 8000/MAX TNT/DSLTNT Administration Guide
TAOS System Administration
Specifying a management-only Ethernet interface
2
Set the User-Profile to null: admin>set user =
3
Set Auto-Logout to Yes: admin>set auto-logout = yes
This automatically logs out the current User profile if DTR is lost on the serial port.
4
Write the profile: admin>write
Now users connecting to the serial port must supply a valid username and password for access to the TAOS unit.
Specifying a management-only Ethernet interface
You can specify that one of the TAOS unit’s Ethernet interfaces is for management only. The management-only interface can be the shelf-controller port or a port on an installed Ethernet card. Following is the relevant parameter, which is shown with its default setting:
[in IP-INTERFACE/{ { any-shelf any-slot 0 } 0 }] management-only-interface = no
Setting Management-Only-Interface to Yes means that incoming traffic on the interface terminates in the system itself. It is not forwarded on any other interface. In addition, only traffic generated by the system is forwarded on the management-only interface. Traffic generated externally is dropped on the interface.
To configure a management interface, proceed as in the following example: admin> read ip-int {{ 1 12 1 } 0}
IP-INTERFACE/{ { shelf-1 slot-12 1 } 0 } read admin> set management-only = yes admin> write
IP-INTERFACE/{ { shelf-1 slot-12 1 } 0 } written
The IfMgr –d command displays a Management Only field to reflect the port’s status.
Overview of TAOS commands
Each card in the TAOS unit has its own set of commands. The commands on the shelf controller typically affect the operation of the entire system. The commands on particular cards, such as the T1 or Ethernet cards, affect only the cards themselves. This section explains the commands available on the shelf controller.
For information about commands available on the cards, see Chapter 1, “Administering Slot
Cards,” or the APX 8000/MAX TNT/DSLTNT Reference. For information on debug commands,
see Chapter 4, “Using Debug Commands.”
APX 8000/MAX TNT/DSLTNT Administration Guide 2-3
TAOS System Administration
Overview of TAOS commands
Command permission-levels
Commands are organized by permission levels, as described in Table 2-1. A user gains access
to a particular command by logging in to the TAOS unit by means of a user profile that
specifies the required permission level. (To create a User profile, see Chapter 5, “Creating User
Profiles.”) By default, the Admin profile specifies permission to execute all commands.
Table 2-1. Permission levels
Permission level
Code
Debug
Diagnostic
System
Term-Serv
Update
User
Description
Allows you to format and manage the PCMCIA cards that store the system software.
Specialized commands used to troubleshoot the cards. Under most circumstances, these commands are not required for correct operation of the TAOS unit, and in some circumstances might produce undesirable results. (For information about the debug
commands, see Chapter 4, “Using Debug Commands.”
Commands used to monitor the TAOS unit and its cards.
Commands that allow you to manage and configure the TAOS unit.
Accesses the TAOS unit’s terminal server.
Commands that allow you to update the system configuration.
Simple commands available to all users that allow log in.
Commands overview
Table 2-2 briefly describes the TAOS commands available on the shelf-controller. Many of the
commands are used in later sections of this manual to perform certain system administration tasks. For complete details of each command, see the APX 8000/MAX TNT/DSLTNT
Reference.
Table 2-2. TAOS system administration commands
Command Name
?
Arptable
Auth
Callroute
Permission Level Effect
User
System
User
Diagnostic
Displays a list of commands.
Displays or modifies the TAOS unit’s Address
Resolution Protocol (ARP) table.
Selects a new User profile.
Displays the call-routing database.
2-4 APX 8000/MAX TNT/DSLTNT Administration Guide
TAOS System Administration
Overview of TAOS commands
Table 2-2. TAOS system administration commands (continued)
Command Name
Clear
Clock-Source
Clr-History
Connection
Date
Debug
Delete
Device
Dir
Dircode
Dnstab
DS3ATMlines
Ether-Display
Help
Fatal-History
Format
Fsck
Get
HDLC
If-Admin
IGMP
IP-pools
Ipcache
Permission Level
User
Diagnostic
System
System
Update
Diagnostic
Update
Diagnostic
System
System
System
System
Diagnostic
User
System
Code
Code
System
System
Diagnostic
System
System
System
Effect
Clears the terminal session screen and places the system prompt at the top row of the VT100 window.
Displays clock-source statistics.
Clears the fatal-error history log.
Displays the connection-status window.
Sets the system date.
Enables or disable diagnostic output.
Permanently deletes a profile from local storage.
Brings a device up or down.
Lists profiles and profile types.
Shows contents of PCMCIA card code.
Displays DNS table entries.
Displays DS3-ATM line information.
Displays contents of received Ethernet packets.
Displays help about a particular command.
Lists fatal-error history log.
Prepares a flash card for use.
Verifies the filesystem on a PCMCIA flash card. If errors are detected, they are reported.
No errors are fixed.
Displays fields in a profile.
Displays HDLC-channel information.
Administer an interface.
Displays IGMP multicast statistics.
Displays the status of the IP address pools configured in the IP-Global profile.
Displays IP route caches.
APX 8000/MAX TNT/DSLTNT Administration Guide 2-5
TAOS System Administration
Overview of TAOS commands
Line
List
Load
Log
Modem
Netstat
New
NSlookup
Table 2-2. TAOS system administration commands (continued)
Command Name
IProute
Nvram
Open
OSPF
Ping
Power
Quiesce
Read
Refresh
Reset
Save
System
System
Update
System
System
System
System
Diagnostic
Permission Level Effect
System
Update
Diagnostic
System
Diagnostic
System
System
System
System
Update
Update
Enables you to manually add or delete IP routes. Routing table changes made by using this command are not remembered across system resets.
Displays the line status window.
Lists fields in working profile.
Uploads code or saved configuration to flash.
Invokes/controls the event log window.
Displays modem information.
Displays routing or interface tables.
Creates a new profile.
Resolves the IP address of a specified host name by performing a DNS lookup.
Clears configuration and reboot system
Starts session with slot card.
Displays information related to OSPF routing, including Link-State Advertisements (LSAs), border routers’ routing tables, and the OSPF areas, interfaces, statistics, and routing table.
Sends ICMP echo_request packets to the specified host as a way to verify that the host is up and the transmission path to the host is open.
Displays power supply statistics.
Temporarily disables a modem or DS0 channel.
Makes the specified profile the working profile.
Refreshes the remote configuration.
Reboots the system.
Saves profile for future restore.
2-6 APX 8000/MAX TNT/DSLTNT Administration Guide
TAOS System Administration
Overview of TAOS commands
Table 2-2. TAOS system administration commands (continued)
Command Name
Screen
Set
Show
Slot
Status
T1channels
Telnet
Terminal-Server
Traceroute
UDS3lines
Uptime
Userstat
Version
View
Whoami
Write
System
System
Diagnostic
System
System
Diagnostic
Termserv
Diagnostic
Permission Level Effect
System
System
Diagnostic
System
System
System
User
Update
Changes the status window display size for the current session.
Sets a parameter’s value.
Shows shelves, slots, or items.
Administers a slot card.
Displays system status or hide status window.
Displays T1 channel information.
Opens a Telnet session to another host.
Enters terminal-server mode.
Traces the route an IP packet follows by launching UDP probe packets.
Displays unchannelized DS3 line information.
Displays how long the TAOS unit has been up since its last reset.
Displays user-session status.
Displays software version information.
Changes content of a status window.
Displays current User profile name.
Writes a profile.
APX 8000/MAX TNT/DSLTNT Administration Guide 2-7
TAOS System Administration
Displaying system and slot card uptime
Displaying system and slot card uptime
The Uptime command reports how long the system and its individual cards have been up. The slotLastChange
MIB object in the Lucent Enterprise MIB also enables network management stations to obtain uptime information.
The Uptime command uses the following syntax: super->help uptime uptime usage: uptime [ [ -a ] | [ [ shelf ] slot ] ] uptime display the TNT system uptime.
uptime slot display the TNT slot card uptime.
uptime shelf slot display the TNT slot card uptime.
uptime -a display the uptime for all TNT slot cards.
uptime -? display this usage message.
Without an argument, the command displays system uptime. But in the following example, the command displays the uptime for all slot cards in the UP state (cards that are not in the UP state are not reported): super->uptime -a
22:03:43
{ shelf-1 slot-2 } csmx-card 3 days 05:23:08 8.0.2c5
{ shelf-1 slot-4 } hdlc2ec-card 3 days 05:24:00 8.0.2c5
{ shelf-1 slot-5 } madd2-card 3 days 05:23:52 8.0.2c5
{ shelf-1 slot-7 } oc3-atm-card 3 days 05:24:18 8.0.2c5
{ shelf-1 slot-8 } hdlc2ec-card 3 days 05:24:00 8.0.2c5
{ shelf-1 slot-9 } ether3-card 3 days 05:24:34 8.0.2c5
{ shelf-1 slot-12 } hdlc2-card 3 days 05:24:08 8.0.2c5
{ shelf-1 slot-13 } csmx-card 3 days 05:23:08 8.0.2c5
{ shelf-1 slot-14 } hdlc2-card 3 days 05:24:08 8.0.2c5
{ shelf-1 slot-15 } hdlc2ec-card 3 days 05:24:00 8.0.2c5
{ shelf-1 slot-16 } hdlc2ec-card 3 days 05:24:00 8.0.2c5
{ shelf-1 slot-17 } hdlc2ec-card 3 days 05:24:00 8.0.2c5
{ shelf-1 slot-19 } ether3-card 3 days 05:24:34 8.0.2c5
{ shelf-1 slot-20 } hdlc2-card 3 days 05:24:08 8.0.2c5
{ shelf-1 slot-21 } hdlc2-card 3 days 05:24:08 8.0.2c5
{ shelf-1 slot-22 } csmx-card 3 days 05:23:08 8.0.2c5
{ shelf-1 slot-23 } t3-card 3 days 05:24:26 8.0.2c5
{ shelf-1 slot-24 } hdlc2-card 3 days 05:24:08 8.0.2c5
{ shelf-1 slot-25 } hdlc2-card 3 days 05:24:08 8.0.2c5
{ shelf-1 slot-26 } csmx-card 3 days 05:23:08 8.0.2c5
{ shelf-1 slot-27 } hdlc2-card 3 days 05:24:08 8.0.2c5
{ shelf-1 slot-29 } ether3-card 3 days 05:24:34 8.0.2c5
2-8 APX 8000/MAX TNT/DSLTNT Administration Guide
TAOS System Administration
Displaying the system version
{ shelf-1 slot-30 } csmx-card 3 days 05:23:08 8.0.2c5
{ shelf-1 slot-33 } t3-card 3 days 05:24:26 8.0.2c5
{ shelf-1 slot-34 } hdlc2ec-card 3 days 05:24:00 8.0.2c5
{ shelf-1 slot-36 } 8t1-card 3 days 05:24:46 8.0.2c5
{ shelf-1 slot-38 } ether3-card 3 days 05:24:34 8.0.2c5
{ shelf-1 slot-39 } ether3-card 3 days 05:24:34 8.0.2c5
{ shelf-1 left-controller } shelf-controller 3 days 05:25:51 (
PRIMARY )
Note:
The left and right controllers are both reported in the display.
Uptime displays the current time (
20:18:18 in the preceding example), identifies the slot card, the software version running on the card, and displays the length of time the system has been up, in days followed by hours:minutes:seconds. The following example shows that a csmx card in slot 2 has been up for 3 days, 5 hours, 23 minutes and 8 seconds: super->
uptime 1 2
20:18:18
{ shelf-1 slot-2 } csmx-card 3 days 05:23:08 8.0.2c5
Displaying the system version
Use the Version command to determine which system software version is installed. For example: admin> version
Software version 8.0.1
Viewing the factory configuration
The read-only Base profile displays the software versions, enabled features, network interfaces, and other system information. To view the Base profile, use the Get command. For example: admin>get base
[in BASE] shelf-number = 1 software-version = 8 software-revision = 0 software-level = b manufacturer = dba-lucent-mfg d-channel-enabled = yes aim-enabled = yes switched-enabled = yes multi-rate-enabled = yes t1-pri-conversion-enabled = yes frame-relay-enabled = yes maxlink-client-enabled = enabled
APX 8000/MAX TNT/DSLTNT Administration Guide 2-9
TAOS System Administration
Viewing the factory configuration
data-call-enabled = yes r2-signaling-enabled = no serial-number = 7050270 hardware-level = 0 countries-enabled = 511 domestic-enabled = yes modem-dialout-enabled = yes firewalls-enabled = no network-management-enabled = no phs-support = no selectools-enabled = no routing-protocols-disabled = no apx-adsl-restricted = no apx-sdsl-restricted = no apx-idsl-restricted = no xcom-ss7 = disabled ss7asg = disabled atmp-enabled = enabled l2tp-enabled = disabled pptp-enabled = disabled ipinip-enabled = disabled
The Base profile displays system information that is not modified across resets. These values are read from the system ROM, security PAL, and from the hardware assembly itself. (For information about the parameters, see the APX 8000/MAX TNT/DSLTNT Reference.)
Note:
The shelf-number is always 1 in a single-shelf system. In a multi-shelf system, it must be unique for each shelf.
Adjusting screen width
The TAOS unit allows command-line input and terminal-server banners up to 255 characters, rather than the previous limit of 80 characters. Horizontal scrolling of the command line allows viewing of commands and banners that are wider than the terminal display.
To set the width of the terminal display window for the current session, use the Screen command. To specify the width to use for every login to the command-line interface, use the
Screen-Width parameter in a User profile.
Setting screen width for the current session
The Screen command enables you to specify the width of the screen. The command uses the following syntax: screen -w <width>
The Width argument is a value from
80
to
256
and default is
80
. For example: admin> screen -w 256
The specified screen width is the number of characters that are visible without scrolling, including the system prompt and spaces following it. For example, if the screen width is 80 characters and the prompt is admin>
(a 6-character prompt followed by a space), the maximum number of visible characters in a command is 72. If the user enters a long command,
2-10 APX 8000/MAX TNT/DSLTNT Administration Guide
TAOS System Administration
Setting the system name
for example that has 100 characters, 28 of the characters will not be visible at any one time.
The user can scroll to the characters not currently visible by moving the cursor left or right.
The following control sequence allows users to redraw the current line:
Control sequence
Ctrl-L, Ctrl-R
Effect
Redraw line
All existing control sequences continue to work as in previous releases. For details, see the
TAOS Command-Line Interface Guide.
Customizing a User profile for screen width
To enable you to specify the screen width for all subsequent sessions, the following parameter
(shown with its default setting) has been added to User profiles:
[in USER/""] screen-width = 80
Parameter
Screen-Width
Specifies
Number of characters allowed on a command line or terminal-server banner. An integer from 80 (the default) to 255.
Following is an example of how to customize a user’s profile for a screen width of 120 characters: admin> read user admin
USER/admin read admin> set screen-width = 120 admin> write -f
USER/admin written
Setting the system name
The TAOS unit sends this name to callers whenever it establishes a PPP link. The name is not used in DNS lookups.
You specify the system name in the System profile. For example, to set the TAOS unit’s system name to apx01 , proceed as follows: admin> read system
SYSTEM read admin> set name = apx01 admin> write
SYSTEM written
APX 8000/MAX TNT/DSLTNT Administration Guide 2-11
TAOS System Administration
Setting the system time and date
Setting the system time and date
This section explains how to set the TAOS unit’s system clock. The TAOS unit can also use
Simple Network Time Protocol (SNTP—described in RFC 1305) to set and maintain its system time by communicating with an SNTP server across an IP interface. For information about configuring the TAOS unit to use SNTP, see the APX 8000/MAX TNT/DSLTNT WAN,
Routing, and Tunneling Configuration Guide.
Use the Date command to set the system time and date if it is incorrect when the system initializes. To view the date and time, enter the Date command with no argument: admin> date
Mon Dec 20 11:11:00 1999
To set it, append the current date and time to the Date command, in the following format: yymmddhhmm
This format uses a two-digit number for each of the following settings: year, month, day, hour, and minute, in that order. For example: admin> date 9911021743
Mon Dec 20 17:43:00 1999
In the year field, 00 - 89 represents years 2000 to 2089, and 90-99 represents years 1990 to
1999. For example, to set a date in the year 1999, proceed as in the following example: admin> date 9910130029
Wed Oct 22 0:29:00 1999
To set a date in the year 2001, proceed as in the following example: admin>
date 0110130029
Sat Dec 25 0:29:00 2001
You can also Get the Timedate profile to view the information: admin> get timedate
[in TIMEDATE] time = { 17 43 34 } date = { Monday December 2 1998 }
The Time and Date parameters in the Timedate profile cannot be set directly. To change their values, use the Date command as shown above.
Managing onboard NVRAM
The system configuration is stored in the onboard non volatile random access memory
(NVRAM). Some error conditions might require that you clear the TAOS unit’s configuration and reboot. When you clear NVRAM, the system is reinitialized and comes up unconfigured, just as it was when you first installed it.
2-12 APX 8000/MAX TNT/DSLTNT Administration Guide
TAOS System Administration
Resetting the unit
!
Caution:
Make sure you have a recent backup before using the NVRAM command.
To see how NVRAM is being used, enter the NVRAM command with the -u option: admin> nvram -u
To clear NVRAM, restoring the unit to its initial, unconfigured state, enter the NVRAM command without specifying an option: admin> nvram
To clear NVRAM and enter debug mode, use the -t option: admin> nvram -t
Resetting the unit
When you reset the TAOS unit, it restarts and terminates all active connections. All users are logged out and the default security level, configured in the User-Profile parameter, is reactivated. In addition, a system reset can cause a WAN line to temporarily be shut down due to momentary loss of signaling or framing information.
To reset the unit, enter the Reset command: admin> reset
During a reset, the TAOS unit runs its Power-On Self Test (POST), just as it would if the unit were power-cycled.
Viewing clock-source information
If a line is specified as the clock-source, it can be used as the source of timing information for synchronous connections, so both the sending device and the receiving device can determine where one block of data ends and the next begins. If multiple T1 lines specify that they are the clock-source (the default configuration), you can assign clock-source priority among multiple
T1 lines.
To view the clock-source statistics, enter the Clock-Source command: admin> clock-source
Master: slot-1/1 line 3
Source List:
Source: slot-1/1 Available priority: 1
Sources with layer 2 up, which are preferred, are marked with an asterisk. For information about configuring the clock source, see the hardware installation guide.
APX 8000/MAX TNT/DSLTNT Administration Guide 2-13
TAOS System Administration
Viewing clock-source information
DOS-compatible FAT-16 flash memory format
Shelf controller PCMCIA flash memory cards use a DOS-compatible general-purpose file system. In the initial release, the file system is supported on the TAOS shelf controller
PCMCIA flash cards and Intel-compatible linear flash cards, but it has been designed with a minimum of platform dependencies.
The new flash format allows for hierarchical directories and eliminates the need to revise the file system format between versions. In addition, you can read and write the data on the flash card with a standard laptop or palmtop running OS/2 or a Windows version that supports Flash
Translation Layer (FTL) linear flash memory.
File formats
The file allocation table-16 (FAT-16) file system is implemented on top of FTL. For details about the formats, see PCMCIA Media Storage Formats, Chapter 5: Flash Translation Layer
Microsoft FAT12 and FAT16 volume formats.
Note:
Filenames on TAOS flash cards must be compatible with the DOS 8.3 format.
A FAT-16 file system can store a large number of files in a hierarchy of directories. After you format flash under this software version, the flash card contains a top-level directory named
/current
, which contains the currently running version of the TAOS software as well as code image files for all supported slot cards. The slot card images are extracted from the tar file and stored as individual files with a .
ffs
filename extension. For example: apxsr.ffs
tnt8t1.ffs
tnthdlc2.ffs
The new flash format also allows you to load a new software version or configuration data to the TAOS from a laptop running Windows or OS/2, rather than from a TFTP server. Because the FAT on FTL format is supported only on linear flash cards in this release, the laptop must have FTL linear flash.
Loading file to the flash file system
The Load command supports an image type of file for Trivial File Transfer Protocol (TFTP) transfers to a flash card formatted for the FAT-16 format. Images of type file are not checked for an Internet Telnet Protocol (ITP) header, and are stored by name in the
/current directory of the specified flash card. For example, the following command loads a voice-announcement file named busy.au
from a TFTP server at 10.10.10.10 to the
/current directory on flash card 1 (the default): admin> load file network 10.10.10.10 busy.au
When used to load a tar file, the Load command lists the filename of each code image in the file as the image is being extracted. For example: admin> load tar network 10.10.10.10 apxrel.tar file apxrel.tar...
untaring and loading image for...
shelf controller (apxsr/apxsr.ffs)...
8t1-card (tnt8t1/tnt8t1.ffs)...
skipping t3-card (tntt3/tntt3.ffs)...
2-14 APX 8000/MAX TNT/DSLTNT Administration Guide
TAOS System Administration
Using PCMCIA flash cards
ether3-card (tntenet3/tntenet3.ffs)...
hdlc2-card (tnthdlc2/tnthdlc2.ffs)...
skipping 4swan-card (tntswan/tntswan.ffs)...
skipping 48modem-56k-card (tntmdm56k/tntmdm56k.ffs)...
skipping 48modem-card (tntmdm/tntmdm.ffs)...
done.
Creating directories in the flash file system
The mkdir command creates directories in the flash file system. The slash character (/) separates the elements of a pathname. For example, the following command creates a directory named oldconf at the top level of the flash card in slot 1: admin> mkdir 1/oldconf
The following command creates a subdirectory named config1
within the oldconf directory: admin> mkdir 1/oldconf/conf1
You can move files into a directory by using the mv command. For example, the following command moves a file named 0001conf to the new subdirectory on flash card 1: admin> mv 1/current/0001conf 1/oldconf/conf1/0001conf
Checking the flash file system
The Fsck command prints a summary of file structures on the card. For example: admin> fsck 2
Volume Stats:
Block Size: 512 (typical: 512)
Blocks Per Cluster: 3 (typical: 1, may be powers of 2 up to 16)
Reserved Blocks: 1 (typical: 1, but may be 0 - hundreds)
Number of FATs: 2 (must be 2)
Number of Root Directory Entries: 96 (typically between 32 and 224)
Total Blocks: 11264
Media Descriptor: f0 (ignored)
Volume Info calculated from values above:
Blocks Per Fat: 11
Fat Start Block: 1
Root Dir Start Block: 23
Data Start Block: 29
Number of Root Dir Blocks: 6
Number of Clusters: 3745
FAT Type: Fat12
Cluster Usage
Usable Clusters: 3743
Free Clusters: 1828
Clusters lost during interrupted writes: 0
Other reserved clusters: 1909
Using PCMCIA flash cards
Each TAOS unit’s shelf supports up to two PCMCIA flash-memory cards. The system comes with onboard NVRAM, and each flash card provides its own additional memory. At present,
APX 8000/MAX TNT/DSLTNT Administration Guide 2-15
TAOS System Administration
Using PCMCIA flash cards
the flash cards contain code for the slot cards, the shelf-controller, and profiles. The system configuration is stored in the onboard NVRAM.
The PCMCIA slots on the shelf-controller are labeled 1 (the slot on top) and 2 (the slot below).
Formatting a flash card
Before using a PCMCIA card in the TAOS unit, you must format it. First insert the card into slot 1 or slot 2 in the shelf-controller, then use the Format command. Following are examples of formatting the card in slot 1: admin> format flash-card-1
Or: admin> format 1
Flash-card-1 is the card inserted in the leftmost of the two PCMCIA slots.
For a list of error messages that might appear when using the Format command, see
Appendix B, “Log Messages on the TAOS Unit.”
Displaying the contents of flash
The system comes with onboard NVRAM, and each flash card provides its own additional memory. The system configuration is stored in the onboard NVRAM.
To check the slot-card images stored in the flash card code directory, use the Dircode command, as shown in the following example: admin>
dircode
Flash card code directory:
Card 1, directory size 16
shelf-controller reg good 1237961 Nov 24 12:19 8.0
8t1-card reg good 203393 Nov 24 12:19 8.0
t3-card reg good 224951 Nov 24 12:19 8.0
4ether-card reg good 177007 Nov 24 12:19 8.0
hdlc2-card reg good 640052 Nov 24 12:19 8.0
4swan-card reg good 425375 Nov 24 12:19 8.0
10-unchan-t1-card reg good 510029 Nov 24 12:19 8.0
ds3-atm-card reg good 444831 Nov 24 12:19 8.0
csmx-card reg good 806361 Nov 24 12:20 8.0
The information displayed by this command includes the card number (1 or 2) and the size of the code directory. It also shows the following information about each code module:
• Type of card supported
• Subtype of the code, which can be regular or diagnostic
• Status, which can be good (present and complete), write (being copied), or bad
(incomplete or corrupt)
2-16 APX 8000/MAX TNT/DSLTNT Administration Guide
TAOS System Administration
Using PCMCIA flash cards
• Size of the code
• Date the code was loaded to the flash card
• Code version
For a list of error messages that might appear when using the Dircode command, see
Appendix B, “Log Messages on the TAOS Unit.”
Checking the file system
If the Dircode command shows a code status other than Good, or if you suspect inconsistencies in the flash card files, use the Fsck command to check the code directory. The Fsck command checks inconsistent conditions in the code directory as well as file contents on a PCMCIA flash card. For each file found, the command displays the type-name, type-number, decimal and hex byte counts, and date written to flash.
If errors are detected they are reported but not fixed. If the Fsck command reports errors, you should reformat the card and then load the code again. If necessary, download the code file again from the Lucent (Ascend) FTP server.
To check the file-system on the flash card in PCMCIA slot 1, use the Fsck command as shown in the following example: super->fsck 1
Card version info ’SiliconTech ~64MB FLASH
Card~’
Volume Stats:
Block Size: 512 (typical: 512)
Blocks Per Cluster: 16 (typical: 1, may be powers of 2 up to 16)
Reserved Blocks: 1 (typical: 1, but may be 0 - hundreds)
Number of FATs: 2 (must be 2)
Number of Root Directory Entries: 512 (typically between 32 and 224)
Total Blocks: 125952
Media Descriptor: f0 (ignored)
Volume Info calculated from values above:
Blocks Per Fat: 31
Fat Start Block: 1
Root Dir Start Block: 63
Data Start Block: 95
Number of Root Dir Blocks: 32
Number of Clusters: 7866
FAT Type: Fat16
Cluster Usage
APX 8000/MAX TNT/DSLTNT Administration Guide 2-17
TAOS System Administration
Updating system software
Usable Clusters: 7864
Free Clusters: 6048
Clusters lost during interrupted writes: 0
Other reserved clusters: 1798
For details of the command-line options for the Fsck command, see the APX 8000/MAX
TNT/DSLTNT Reference.
Updating system software
For information on updating system software, see the TAOS True Access Operating System
Addendum.
Loading specific slot-card images
The TAOS unit supports a large number of slot cards, so the Tar files containing slot-card code images might be too large to load on an 8MB flash card. The Load-Select administrative profile enables you to specify which slot-card images to load to flash when you use a Load Tar command such as the one shown below: admin> load tar network 10.10.10.10 tntrel.tar
Following a system reset, the TAOS unit creates the Load-Select profile if it is not present. The profile lists the entire set of supported slot-card images and an intended load action for each card type when the image is present in a Tar file. It also contains an Unknown-Cards parameter, which represents new cards that were not supported in the previous system version.
When loading the Tar file, the system uses settings in the Load-Select profile to load only specific slot-card images. To prevent version-related problems, it then deletes code images that were present on the flash card but were not updated.
For examples of upgrade procedures using the Load-Select profile, see the TAOS True Access
Operating System Addendum.
Following are sample contents of the Load-Select profile:
[in LOAD-SELECT] unknown-cards = auto
8t1 = auto
8e1 = auto t3 = auto ut1 = auto ue1 = auto uds3 = auto ds3-atm = auto enet = auto enet2 = auto mdm-v34 = auto mdm56k = auto amdm = auto
2-18 APX 8000/MAX TNT/DSLTNT Administration Guide
TAOS System Administration
Backing up and restoring a configuration
anmdm = auto hdlc = auto hdlc2 = auto swan = auto
Each parameter in the profile represents a card type, and can be set to Auto, Load, or Skip, to specify the action to take when the code image is present in a Tar file. (The Load-Select profile does not list the Shelf-Controller code, because that image is always loaded from the updated
Tar file.)
• The Auto setting (the default) causes the system to load images for cards that are installed in the TAOS unit, and skip images for cards that are not installed. A card is considered present in the system if a Slot-Type profile exists for that card type. The system creates a
Slot-Type profile when it first detects the presence of a card, and does not delete the profile unless the administrator uses the Slot –r command to permanently remove a card that is no longer installed in the system, or clears NVRAM. To ensure that the system does not load unnecessary images, use Slot –r to remove Slot-Type profiles for cards that are no longer installed in the system.
• The Load setting causes the system to load the image, even if there is no card of that type installed.
• The Skip setting causes the system to skip the image, even if there is a card of that type installed.
Loading an extracted code image
You can override the settings in the Load-Select profile with options to the Load command.
For example, if you extract the contents of a Tar archive and then issue the following Load command: admin>
load mdm56k network 10.10.10.10 apxmdm56k.ffs
The system loads the 56K-modem image even if the Load-Select profile indicates that it should be skipped. For details on the Load command, see the APX 8000/MAX TNT/DSLTNT
Reference.
Backing up and restoring a configuration
The Save command saves all configured profiles, all profiles of a specified type, or a specific profile to a file on a local disk or to a file on a network host. You can then use that file to restore the TAOS unit’s configuration. Note that to save passwords, you must have sufficient
Saving the configuration to a local file
To save the TAOS unit’s configuration to a file on the system you are using to access the
TAOS unit, turn on the capture function in your VT100 emulation software, and enter the Save command as follows: admin> save -a console
APX 8000/MAX TNT/DSLTNT Administration Guide 2-19
TAOS System Administration
Backing up and restoring a configuration
The entire configuration is written to the specified file. You might want to print a copy of the configuration for later reference.
The
–a
option saves all parameters, even those that are set to their default values.
Saving the configuration to a network host
To save the configuration on network host, you must specify the hostname and the full path of a filename, as in the following example: admin> save -a network host1 /config/981001 configuration being saved to 10.65.212.19
In the sample command line, host1
is the network host and
/config/981001
is the file name.
Restoring or updating the configuration
You can restore a full configuration that you saved with the Save command, or you can upload more specific configuration information, such as single profile.
To restore configuration information, use the Load command.
Restoring from a local file
Before you start the restore procedure, verify that your terminal emulation program has an autotype (or ASCII file upload) feature. Autotype allows your emulator to transmit a text file over its serial port. You should also verify that the data rate of your terminal emulation program is set to 9600 baud or lower and that the term-rate parameter in the System profile is also set to 9600 or lower, and that the Term-Rate parameter in the System profile is set to the same rate. Speeds higher than 9600 baud might cause transmission errors.
To restore a configuration from a file on the system you are using to access the TAOS unit, set up your VT100 emulation software to send the file, and enter the Load command as follows: admin> load config console
Restoring from a network host
To restore a configuration from a file on a network host, enter the Load command as follows: admin> load config network hostname filename
Where hostname
is the name of the host and filename
is the name of the file in which the configuration is stored.
Updating the configuration
You can use the Load command to upload code for any of the slot cards to a flash card. For example, to upload new code for an eight port T1 card from a file named
8t1.ffs
on a network host named server1
: admin> load t1-8 network server1/cfg/8t1.ffs
2-20 APX 8000/MAX TNT/DSLTNT Administration Guide
TAOS System Administration
Using the status window
Saving and Restoring to a PCMCIA flash card
To save or restore full configuration information, use the Save command, as follows.
super-> ? save save save all configuration profiles, all profiles of a given type,
or a specific profile by writing it in a form that can be replayed
to a unit to restore its configuration
usage: save [ -a ] [ -m ] < target > [ profile-type [ profile-index ] ]
or
specify a list of profiles to be included in or excluded from the
network save operation
usage: save [ -a ] [ -m ] network <host> <filename> [ -p |
-x profile1 profile2 ...]
< target >: network < host > < filename >, console, flash
< device/filename >
[ -a ]: explicitly save all fields, even those with default values
[ -m ]: use mib tags instead of field and value names
[ -p ]: save specified list of profiles
[ -x ]: save all profiles, except the specified list
Using the status window
The status windows provide information about what is currently happening in the TAOS unit.
For example, one status window displays up to 31 of the most recent system events that have occurred since the TAOS unit was powered up, and another displays statistics about the currently active session. An 80-column by 24-row VT100 window is required for use of the status screens.
This section describes the default configuration of the Status windows. For information about
Status window command summary
By default, the status window is not displayed upon login, but only when you explicitly request it with one of the following commands:
• Status—Opens or closes the status window.
• Connection—Opens the status window with the connection information displayed.
APX 8000/MAX TNT/DSLTNT Administration Guide 2-21
TAOS System Administration
Using the status window
• Line—Opens the status window with the line information display.
• Log—Opens the status window with the log information display.
• View—Changes the information displayed in the top or bottom status window.
For details on using these commands, see the APX 8000/MAX TNT/DSLTNT Reference.
Opening and closing the status window
To open the system status window, enter the Status command: admin> status
The system prompt moves just below the status window. If the system prompt is not visible below the status window, press Escape to display it.
To close the status window, enter the Status command again: admin> status
Understanding the status window
The status window (Figure 2-1) has three main areas. In its default configuration, these areas
contain the following information:
• Connection information is displayed on the left side of the window.
• General information, such as serial number, software version, and uptime are displayed in the upper-right side of the window.
• Log information is displayed in the lower-right side of the window.
Figure 2-1. System status window
Left: Connection Top: General
2-22
Bottom: Log
APX 8000/MAX TNT/DSLTNT Administration Guide
TAOS System Administration
Using the status window
Connection status information
With the default setting in a User profile, the left area of the status window initially displays
connection information, as shown in Figure 2-1. One line appears for each active connection,
showing the user or station name, type of connection, T1 shelf, line, and channel on which the call was placed or received, and the bandwidth or baud rate of the connection.
If the status window is not already displayed, or if you want to scroll through the list of connections, use the Connection command as in the following example: admin> connection
If the Status window is not displayed, the Connection command opens it and displays the connection-status-mode message below the Status window (if the Status window is already open, the Connection command just displays the message):
[Next/Last Conn:<dn/up arw>, Next/Last Page:<pg dn/up>,Exit: <esc>]
This message indicates the key sequences you can use for displaying additional information in the Connection status area. The Down Arrow and Up Arrow keys display the next and previous connection, respectively, in the list of active connections.
When the connection-status-mode message is displayed, the system prompt does not appear at the bottom of the window. Press the Escape key to exit this mode and return to the system prompt.
General status information
With the default setting in a User profile, the top area of the status window initially displays general status information about the TAOS unit, including its serial number, the version of system software it is running, and the number of packets transmitted and received. This area also shows the current system date and time and how long the system has been up.
If the top of the status window is displaying another kind of information, such as T1 line information, you can redisplay the general status information with the View command: admin> view top general
Log messages
With the default setting in a User profile, the bottom area of the status window initially displays the most recent message from the TAOS unit’s log buffer. The number of system event messages stored in the log is set by the Save-Number parameter in the Log profile.
The first line of the event log window shows the log entry number (M: 00 through M: N, where
N is set in the save-number parameter of the Log profile), the level of message, and the device on which the event occurred. The last line shows the date and time when the event occurred.
The middle of the window displays the text of the most recent message.
If the status window is not already displayed, or if you want to scroll through the log, use the
Log command: super> log
APX 8000/MAX TNT/DSLTNT Administration Guide 2-23
TAOS System Administration
Using the status window
If the Status window is not displayed, the Log command opens it and displays the log-mode message below the Status window (if the Status window is already open, the Log command just displays the message):
[Back: <up arw>, Forward: <dn arw>, Start: <pg up>, End: <pg dn>, Exit:
<esc>]
This message indicates the key sequences you can use for displaying additional information in the Log area:
• The Down Arrow and Up Arrow keys display the next and previous message in the buffer, respectively.
• The Page Up and Page Down. keys display the first and last message in the buffer, respectively.
When the log-mode message is displayed, the system prompt does not appear at the bottom of the window. Press the Escape key to exit this mode and return to the system prompt.
Displaying WAN line information
The status window can also display information about the WAN lines on the TAOS unit. For
details, see “Displaying line status” on page 1-8.
Changing current status window sizes
The Screen command enables you to change the size of the terminal emulator and status windows for the current session. (For information about changing the terminal emulator and
The following command changes window display sizes for the current session only: admin> screen screen-length [status-length]
If the Status window is open when you execute the Screen command, the Screen command resizes it dynamically. If it is not open, the Status window is resized when you next open it.
The screen-length option specifies the number of lines displayed in the terminal window. Note that screen-length must be at least 6 lines greater than the value of status-length.
The optional status-length option specifies the number of lines displayed in the status window, including dividing lines. The following example changes the terminal window to 55 lines high and the status windows to 22 lines high.
admin> screen 55 22
If you only specify the screen-length option, and it is not greater than the configured
status-length by at least 6 lines, the TAOS unit automatically adjusts the length of the status windows. This is shown in the following example: admin> screen 55 22 new screen-length 55 new status-length 22 admin> screen 24 error: screen-length conflict, adjusting status-length from 22 to 18
2-24 APX 8000/MAX TNT/DSLTNT Administration Guide
TAOS System Administration
Reviewing the fatal error log
new screen-length 24 new status-length 18
Reviewing the fatal error log
The TAOS unit’s fatal error log contains messages related to the its operations.
To view the log of fatal errors, enter the Fatal-History. For example: admin>
fatal-history
OPERATOR RESET: Index: 99 Revision: 2.0
Date: 01/30/2000. Time: 16:55:38
Shelf 1 (apxsr)
Reset from unknown, user profile admin.
SYSTEM IS UP: Index: 100 Revision: 2.0
Shelf 1 (apxsr)
Date: 01/30/2000. Time: 16:56:12
The command’s output information includes the date and time at which the error occurred, the system software version that was running at that time, the slot number on which the error occurred, and a stack trace record of the event. (For a list of fatal error messages, see
Appendix B, “Log Messages on the TAOS Unit.”)
To clear the fatal error log, enter the Clr-History command: admin> clr-history
Configuring message logging
The TAOS unit generates error and event messages related to its operations. You can display these messages with the following commands:
• Log—Invoke or control the event log window.
• Fatal-History—List fatal error history log.
In the Log and User profiles you can configure the way in which the messages are handled .
The Log profile defines system-wide event logging parameters, including the number and level of messages to save and whether to communicate with a Syslog daemon.
Table 2-3 lists the sections describing common tasks you might have to perform to configure
message logging on the TAOS unit. The table includes a brief description of each task, and lists the parameters you will use.
APX 8000/MAX TNT/DSLTNT Administration Guide 2-25
TAOS System Administration
Configuring message logging
(For complete information about the associated parameters, see the APX 8000/MAX
TNT/DSLTNT Reference.)
Table 2-3. Overview of configuring logging on a TAOS unit
Task
Configuring system logging on a
Configuring Syslog on the TAOS unit
Description of task Related parameters
You can configure the level and number of messages that are logged to the TAOS unit’s log. These messages are displayed in the log status window.
Save-Number
Save-Level
Syslog is an IP protocol that allows you to track events on the TAOS unit. A host running a
Syslog daemon is typically a UNIX host, but it may also be a Windows system.
Sylsog-Enabled
Call-Info
Host
Port
Facility
Configuring system logging on a TAOS unit
The TAOS unit records system events in its status window event log. You can use the
Save-Level and Save-Number parameters in the Log profile to configure the level and number of messages logged.
The Save-Level parameter specifies the lowest level of message to be saved for status display.
The lowest possible level is None (this is the default). The highest level is Debug. For a list of the log message levels, see the APX 8000/MAX TNT/DSLTNT Reference.
The Save-Number parameter specifies the number of messages to be saved in the status display. The default is 100.
To configure the system log on the TAOS unit, proceed as in the following example:
1
Read in the Log profile: admin> read log
LOG read
2
Specify the type of message you want logged: admin> set save-level = emergency
3
Specify the number of messages to save in the event log: admin> set save-number=200
4
Write the profile to save the changes: admin> write
LOG written
Specifying a session ID base
The SessionID-Base parameter specifies the base number to use for generating a unique ID for each session. If SessionID-Base is zero, the TAOS unit sets the initial base for session IDs to the absolute clock. For details, see the APX 8000/MAX TNT/DSLTNT Reference.
2-26 APX 8000/MAX TNT/DSLTNT Administration Guide
TAOS System Administration
Configuring message logging
Configuring Syslog on the TAOS unit
To maintain a permanent log of a TAOS unit’s system events and send Call Detail Reporting
(CDR) reports to a host that can record and process them, configure the TAOS unit to report events to a Syslog host on the local IP network.
The host running a Syslog daemon is typically a UNIX host, but it may also be a Windows system. If the log host is not on the same subnet as the TAOS unit, it must have a route to that
Note:
Do not configure the TAOS unit to send reports to a Syslog host that can only be reached by a dial-up connection. That would cause the TAOS unit to dial the log host for every logged action, including hang ups.
To configure Syslog, you might need to set some or all of the following parameters:
Parameter
Sylsog-Enabled
Call-Info
Host
Port
Facility
Syslog-Format
Description
Enables Syslog.
Specifies whether the TAOS unit sends a one-line Syslog message to the Syslog host when an authenticated call terminates. This message includes information such as the called and calling number and the encapsulation, data rate, and length of session.
The IP address of the Syslog host.
Specifies the port number on which the remote Syslog daemon is listening. It is set to port 514 by default.
Identifies the messages as being from a particular TAOS unit.
Specifies whether the messages the TAOS unit sends to Syslog are in TAOS format (the default) or in another format as other
Lucent products.
To configure Syslog reporting on the TAOS unit, proceed as in the following example:
1
Read in the Log profile: admin> read log
LOG read
2
Enable Syslog: admin> set syslog-enabled = yes
3
Specify that you want end of call information sent: admin> set call-info=end-of-call
4
Specify the IP address of the host running Syslog: admin> set host=10.2.3.4
5
Specify the port the Syslog daemon is listening on: admin> set port=588
APX 8000/MAX TNT/DSLTNT Administration Guide 2-27
TAOS System Administration
Checking the power supplies
The TAOS unit will send all messages out on this port as soon as you write the Log profile.
6
Specify the Syslog facility: admin> set facility=local0
After setting a log facility number, you need to configure the Syslog daemon to write all messages containing that facility number to a particular log file. This file will be the
TAOS unit log file.
7
Specify the format of Syslog messages: admin> set syslog-format = max
8
Write the profile to save the changes: admin> write
LOG written
Note that Call-Info is intended for diagnostic support. It uses UDP, which provides no guaranteed delivery, so it should not be used for billing purposes.
Configuring the Syslog daemon
To configure the Syslog daemon to interact with the TAOS unit, you need to modify the
/etc/syslog.conf
file on the log host. This file specifies which action the daemon will perform when it receives messages from a particular log facility number (which represents the
TAOS unit). For example, if you set Log Facility to Local5 in the TAOS unit, and you want to log its messages in
/var/log/tnt01
, add the following line to
/etc/syslog.conf
: local5.info<tab>/var/log/tnt01
Note:
The Syslog daemon must reread
/etc/syslog.conf
after it has been changed.
Checking the power supplies
To check the status of the APX 8000 unit’s redundant power supplies, enter the Power command. For example: admin> power
Power supply A not present
Power supply B present, OK temp= OK
Power supply C present, OK temp= OK
Power supply D not present
You can also use the Lucent Power Supply MIB to manage and monitor the power supplies.
Using a script to configure the TAOS unit
The TAOS unit’s CLI allows you to create configuration scripts with a simple text editor and a
Telnet client program with a Text Upload feature. This section briefly describes how you could use a script to make changes to the TAOS unit’s configuration.
Following are the basic steps:
2-28 APX 8000/MAX TNT/DSLTNT Administration Guide
TAOS System Administration
Using a script to configure the TAOS unit
1
Create a text file that contains the configuration commands as you would enter them in the
TAOS unit’s CLI.
2
Log into the TAOS unit with sufficient permissions to change the configuration.
3
To upload the file to the TAOS unit, use the upload file feature of your Telnet or terminal software.
Creating a text file
Following is an example of a text file that configures a T1 line in shelf 1, slot 1.
new T1 set name = SF set physical-address shelf = shelf-1 set physical-address slot = slot-1 set physical-address item-number = 1 set line-interface enabled = yes set line-interface frame-type = esf set line-interface encoding = b8zs set line-interface clock-source = eligible write -f
;
Note:
The Write -f command causes the script to overwrite an existing configuration without prompting.
You can use this file as a basis for configuring all twenty-eight lines on a DS3 card by changing the parameters, such as Item-Number, as required. Carefully review your text file to make sure it is correct.
Logging into the TAOS unit
To log into the TAOS unit for administrative tasks, use a profile that has write permissions, as in the following example:
% telnet mytnt
User: admin
Password: mypassword admin>
If you are already logged into the TAOS unit, make sure you are at the highest level by entering the list ..
command (possibly more than once), as in the following example: admin>list .. name = ““ physical-address* = { shelf-1 slot-1 1 } line-interface = { yes esf b8zs eligible middle-priority inband wink-start digi+ admin>list .. error: at highest level
APX 8000/MAX TNT/DSLTNT Administration Guide 2-29
TAOS System Administration
Displaying user session information
Uploading the text file
Use an ASCII text upload to upload the text file directly to the TAOS unit’s prompt. Carefully review your changes through the console.
Displaying user session information
You can obtain TAOS system user session information with the Userstat and Finger commands.
Using the Userstat command
The Userstat command displays the active users on the TAOS unit. To display the most complete information about active sessions, use the -l option, as in the following example: admin>
userstat -l
SessionID Line/Chan Slot:Item Tx/Rx Rate Svc Address Username
228687860 1.01.02/01 1:03:01/01 56K/56K PPP 10.100.0.1 barney
228687861 1.02.03/02 1:04:02/00 28800/33600 PPP 10.168.6.24 jake
<end user list> 2 active user(s)
Following are the Userstat output fields with descriptions:
Field
SessionID
Line/Chan
Slot:Item
Tx/Rx Rate
Description
Unique ID assigned to the session.
Physical address (shelf.slot.line/channel) of the network port on which the connection was established, (for example, a T1 line/channel).
Shelf:slot:item/logical-item of the host port to which the call was routed (for example, modem, HDLC channel).
Transmit and receive rate. Note that for modem connections, the transmit rate is set automatically to the receive rate, because modem cards do not support asymmetric data rate connections.
2-30 APX 8000/MAX TNT/DSLTNT Administration Guide
TAOS System Administration
Displaying user session information
Field
Svc
Description
Type of service in use for the session. Following are the possible values:
--- (The service is being negotiated.)
PPP (Point-to-Point Protocol)
SLP (Serial Line IP)
MPP (Multilink Protocol Plus)
MP (Multilink Protocol)
X25 (X.25)
FRY (Frame Relay)
EUR (EU-RAW)
EUI (EU-UI)
TLN (Telnet)
BTN (Binary Telnet)
TCP (raw TCP)
TRM (Terminal Server)
VCN (Virtual Connect)
D25 (D-channel X.25)
DTP (DTPT)
The number dialed to initiate this session.
Dialed#
(displays only with -l option)
ConnTime
(displays only with -l option)
IdleTime
(displays only with -l option)
The amount of time (in hours:minutes:seconds format) since the session was established.
The amount of time (in hours:minutes:seconds format) since data was last transmitted across the connection.
To terminate a user, use the
-k
option, as in the following example: admin>
userstat
SessionID Line/Chan Slot:Item Rate Svc Address Username
246986325 1.01.02/01 1:13:01/000 33600 PPP 100.100.8.2 100.100.8.2
<end user list> 1 active user(s) admin>
userstat -k 246986325
Session 246986325 cleared
The Userstat command can terminate PPP, SLIP, MP+, Telnet, Telnet binary, Raw TCP, or terminal server user sessions. You cannot use the -k option to terminate Frame Relay or DTPT service types.
You can configure the Userstat command output with the Userstat-Format parameter. For information, see the APX 8000/MAX TNT/DSLTNT Reference.
Userstat options to display address and username
The Userstat command supports the following new options:
•
-a
, to take the IP address of a session as input and display the associated session details.
•
-u
, to take a username and display the associated session details.
•
-o
, to restrict the Userstat command output to specified fields.
Following is the new command usage statement:
APX 8000/MAX TNT/DSLTNT Administration Guide 2-31
TAOS System Administration
Displaying user session information
admin> help userstat userstat usage: userstat -options [ params ] [ -o [format] ]
command options:
-s show users (default)
-k <sessionID> kill a user session
-a <ipAddress> show the session with matching <ipAddress>
-u <username> show the session with matching <username>
-l wide format (> 80 characters)
-d dump, do not pass output through more
format values:
One or More of the following format characters
%i SessionID
%l Line/Chan
%s Slot:Item
%r Tx/Rx Rate
%d Type of Service
%a Address
%u Username
%c ConnTime
%t IdleTime
%n Dialed#
default : %i %l %s %r %d %a %u %c %t %n
Using the -o format specifier option
Use the -o option with one or more format specifiers to display only the fields of interest. For example, for an active session, the Userstat command shows the following details: admin> userstat
SessionID Line/Chan Slot:Item Tx/Rx Rate Svc Address Username
288532030 1.01.01/012 1:03:01/002 56000/56000 PPP 1.1.1.238 net1
<end user list> 1 active user(s)
If you use the
-o
option and indicate the codes for SessionID and Line/Channel information, the command shows only the following details: admin> userstat -o %i %l
SessionID Line/Chan
288532030 1.01.01/012
<end user list> 1 active user(s)
Using the -a and -u options
Use the
-a
option to display information related to a known IP address. It requires an IP address argument on the command line. For example: admin> userstat -a 1.1.1.238
SessionID Line/Chan Slot:Item Tx/Rx Rate Svc Address Username
288532030 1.01.01/012 1:03:01/002 56000/56000 PPP 1.1.1.238 net1
<end user list> 1 active user(s)
To display only the relevant username, include the -o option as follows: admin> userstat -a 1.1.1.238 -o %u
2-32 APX 8000/MAX TNT/DSLTNT Administration Guide
TAOS System Administration
Displaying user session information
Username net1
<end user list> 1 active user(s)
Use the -u option to display information related to a known username. It requires a user-name argument on the command line. For example: admin> userstat -u net1
SessionID Line/Chan Slot:Item Tx/Rx Rate Svc Address Username
288532030 1.01.01/012 1:03:01/002 56000/56000 PPP 1.1.1.238 net1
<end user list> 1 active user(s)
To display only the user’s IP address, include the
-o
option as follows: admin> userstat -u net1 -o %a
Address
1.1.1.238
<end user list> 1 active user(s)
Using the Finger command
Finger is described in RFC 1288. To enable it in the TAOS unit, set the Finger parameter to
Yes, as follows:
1
Read the IP-Global profile: admin> read ip-global
2
Set Finger to Yes: admin> set finger = yes
3
Write the profile: admin> write
The default value for this parameter is No, which causes the TAOS unit to reject queries from
Finger clients with the following message:
Finger online user list denied.
Setting the Finger parameter to Yes enables the TAOS unit to accept Finger queries and return the requested active session details to a remote client. The client can ask for a short or wide format. For example, a UNIX client can request the wide (140-character) format by using the
-l option, as in the following command which displays, in wide format, session information for the system named apx1 :
#
finger -l @apx1
The following command displays the same information in narrow (80-character) format:
#
finger @apx1
The client can also request the details of all sessions, or of a single session. For example, to request information about a single user named Tupshin:
#
finger tupshin@apx1
APX 8000/MAX TNT/DSLTNT Administration Guide 2-33
TAOS System Administration
Remote management of other units
The Finger forwarding service, which uses the hostname format
@host1@host2
, is not supported. If the remote client uses the forwarding request format, the client sees the following message:
Finger forwarding service denied.
Remote management of other units
The Remote command is available in the terminal-server interface on host cards that accept digital calls, and as a command on the TAOS shelf controller. As on other TAOS platforms, the Remote command is used to remotely manage another unit.
Opening a remote management session
During a remote management session, the user interface of the remote device is displayed as if you had opened a Telnet connection to the device. For example: admin> remote allwynp50
allwynp50 Edit
Main Edit Menu
Configure
>00-000 System
20-000 Ethernet
30-000 Serial WAN
10-100 1
Link A
B1 A
B2
20-100 Sessions
>1 Active
20-300 WAN Stat
>Rx Pkt: 667435 ^
Tx Pkt:
CRC:
3276757
323v
00-100 Sys Option
>Security Prof:1 ^
Software +8.0+
S/N:4293801 v
00-200 11:23:55
M31 Line Ch
Outgoing Call
20-500 DYN Stat
Qual Good 01:23:44
OK 1 channel
CLU 100% ALU 100%
20-400 Ether Stat
>Rx Pkt: 99871435
Tx Pkt:
Col:
76876757
73298
00-400 HW Config
>BRI Interface
Adrs: 00c05b45390
Enet I/F: AUI
Press Ctrl-n to move cursor to the next menu item. Press return to select it.
Press Tab to move to another window--thick border indicates active window.
The Remote command argument is the station name, which must match the value of a Station parameter in a Connection profile, or the user ID at the start of a RADIUS profile. The connection must use the MP+ protocol, and the connection must already be established when you use the Remote command.
When you use the Remote command on the shelf controller, it locates the host card that has an active connection to the remote unit. It then opens a session to that card, invokes the terminal-server interface, and uses the Remote command on the card to bring up the remote management session. The Remote command uses a proprietary protocol to connect to the remote unit and bring up its LCD menu, which can be used to reconfigure the unit. However, because your initial permissions are set by the default Security profile on the remote system, you might need to authenticate the Full Access or other administrator-level Security profile before managing the unit.
2-34 APX 8000/MAX TNT/DSLTNT Administration Guide
TAOS System Administration
Remote management of other units
You can also manually open a session with the host card that has an active connection to the remote unit, invoke the terminal-server, and run the Remote command on the slot card. For example: admin> userstat -s
SessionID Line/Chan Slot:Item Tx/Rx Rate Svc Address Username
228687860 1.01.02/01 1:03:01/01 56K/56K PPP 10.100.0.1 clarap75
228687861 1.02.03/02 1:04:02/00 28800/33600 MPP 10.168.6.24 allwynp50
<end user list> 2 active user(s) admin> open 1 4 hdlc2-1/4> terminal-server ascend% remote allwynp50
Terminating a remote management session
To exit from the remote management session and return to the command-line interface session on the shelf controller, press Ctrl-C three times in quick succession.
If you opened the session on a slot card, press Ctrl-\ to end the session. You can then quit the terminal server and the slot card session to return to the shelf controller.
Either end of the connection can terminate an MP+ connection by hanging up all channels of the connection.
Note:
A remote management session can time out, because the traffic it generates does not reset the idle timer. Therefore, the Idle parameter in the Connection profile at both the calling and answering ends of the connection must be disabled during a remote management session, and restored just before exiting. Remote management works best at higher terminal speeds.
Error messages
The TAOS generates an error message for any condition that causes the session to terminate before sending the full number of packets. The following error messages can appear:
Message
not authorized cannot find profile for <station> profile for <station> does not specify MPP cannot establish connection for
<station>
<station> did not negotiate MPP
Explanation
Permissions are insufficient for beginning a remote management session. You must authenticate a User profile that enables the
System permission.
No profile was found for the specified station name.
A profile was located for the specified station name, but it did not specify the MP+ encapsulation protocol.
The MP+ connection to the remote station could not be established.
The remote station did not negotiate an MP+ connection. Possibly the profile for the TAOS dial-in did not specify MP+.
APX 8000/MAX TNT/DSLTNT Administration Guide 2-35
TAOS System Administration
Reloading profiles from RADIUS
Message
far end does not support remote management management session failed far end rejected session
Explanation
The remote station is running a version of
TAOS that does not support remote management.
A temporary condition, such as premature termination of the connection, caused the management session to fail.
The remote station was configured to reject remote management. (The Remote Mgmt parameter was set to no
in the remote station’s System profile.)
Reloading profiles from RADIUS
Use the Refresh command to open a connection to a RADIUS server and retrieve the latest configuration information. (For information about RADIUS, see the APX 8000/MAX
TNT/DSLTNT Reference.)
The Refresh command uses the following syntax:
refresh -a|-n|-p|-r|-t
-r
-t
-s
Option
-a
-n
-p
Description
Refresh all types of configuration.
Refresh nailed profiles configuration.
Refresh address pools configuration.
Refresh static routes configuration.
Refresh terminal server configuration.
Clears the current Source Auth information (purging all existing
Source Auth entries from the cache) and reloads it from RADIUS.
When you use the -n option, the TAOS unit requests a reload of all nailed profiles from the
RADIUS server: admin> refresh -n
You can specify how nailed connections are handled following a Refresh –n by using the
Perm-Conn-Upd-Mode parameter in the System profile. If set to All (the default), all existing permanent connections are brought down and then brought up again (along with any new connections) following the update. This causes service interruption every time any nailed profile is updated or added.
If set to Changed, only new connections are created, and only those with modified attribute values are reestablished.
2-36 APX 8000/MAX TNT/DSLTNT Administration Guide
TAOS System Administration
Configuring the dialout timer
Configuring the dialout timer
The Max-Dialout-Time parameter in the System profile specifies the maximum number of seconds the system waits for a Call Setup Complete from the remote side when dialing out. If the TAOS unit cannot establish the call before the timer expires, the dialout attempt fails. The dialout timer allows increased flexibility for international dialing.
Valid values are from 0 to 255. The default is 20 seconds. If set to zero, the TAOS unit uses its internal default of 20 seconds. In the following example, the dialout timer is set to 60 seconds: admin> read system
SYSTEM read admin> set max-dialout-time = 60 admin> write
SYSTEM written
The Max-Dialout-Time setting does not influence the modem timeout to detect carrier.
Modems have an internal timer that counts down from dialout to establishing carrier with the remote modem (including training) which for Rockwell modems has a default of 45 seconds.
APX 8000/MAX TNT/DSLTNT Administration Guide 2-37
Network Administration
3
The TAOS unit supports several network management commands, which are useful for locating the sources of problems on the network and for communicating with other hosts for management purposes.
Some of the network management tools focus on routing and interface information. They enable you to display the routing and interface tables, view real-time routing statistics, display route caches, and make changes to the routing table. The OSPF command supports numerous arguments for viewing information about the OSPF link-state database, adjacencies, and other aspects of the router configuration.
Other tools are geared toward network usage, and enable you to display packets received on
LAN interfaces, display the ARP cache, Ping a host, and log into a host by means of Rlogin or
Telnet.
For complete information about the commands described in this chapter, see the APX
8000/MAX TNT/DSLTNT Reference.
Diagnostic tools for TCP/IP networks
The TAOS unit maintains an internal IP routing table. You can configure the system to use RIP or OSPF to propagate the information in that table to other routers, receive information from other routers, or both, on any LAN or WAN interface. For information about configuring the router, see the APX 8000/MAX TNT/DSLTNT WAN, Routing, and Tunneling Configuration
Guide.
Using the Ping command to test connectivity
The Ping command is useful for verifying that the transmission path between the TAOS unit and another station is open. Ping sends an ICMP echo_request packet to the specified station. It
APX 8000/MAX TNT/DSLTNT Administration Guide 3-1
Network Administration
Diagnostic tools for TCP/IP networks
the station receives the packet, it returns an ICMP echo_response packet. For example, to Ping the host techpubs
: admin>
ping techpubs
PING techpubs (10.65.212.19): 56 data bytes
64 bytes from 10.65.212.19: icmp_seq=0 ttl=255 time=0 ms
64 bytes from 10.65.212.19: icmp_seq=3 ttl=255 time=0 ms
^C
--- techpubs ping statistics ---
2 packets transmitted, 2 packets received, 0% packet loss round-trip min/avg/max = 0/0/0 ms
You can terminate the Ping exchange at any time by pressing Ctrl-C. When you press Ctrl-C, the command reports the number of packets sent and received, the percentage of packet loss, the number of duplicate or damaged echo_response packets (if any), and round-trip statistics.
In some cases, round-trip times cannot be calculated.
During the Ping exchange, the TAOS unit displays information about the packet exchange, including the Time-To-Live (TTL) of each ICMP echo_response packet.
The maximum TTL for ICMP Ping is 255, while and the maximum TTL for TCP is often 60 or lower, so you might be able to Ping a host but not be able to run a TCP application (such as
Telnet or FTP) to that station. If you Ping a host running a version of Berkeley UNIX before
4.3BSD-Tahoe, the TTL report is 255 minus the number of routers in the round-trip path. If you Ping a host running the current version of Berkeley UNIX, the TTL report is 255 minus the number of routers in the path from the remote system to the station performing the Ping.
Using the Netstat command to display the interface table
At system startup, the TAOS unit creates an IP interface, in the active state, for each Ethernet interface that has a configured IP-Interface profile, and for the built-in loopback, reject, and blackhole interfaces. It also creates IP interfaces in the inactive state for remote connections.
For each IP interface that is not configured as a private route, the TAOS unit also adds a route to the routing table.
IP interfaces change between the active and inactive state as switched calls are brought up and
netstat -i
-in
option, as in the ie0 1500 192.168.7.0/24 192.168.7.135 71186 2 53131 96 lo0 1500 127.0.0.1/32 127.0.0.1 53195 0 53195 0 rj0 1500 127.0.0.2/32 127.0.0.2 0 0 0 0 bh0 1500 127.0.0.3/32 127.0.0.3 0 0 0 0 wanabe 1500 127.0.0.3/32 127.0.0.3 0 0 0 0 local 65535 127.0.0.1/32 127.0.0.1 59753 0 59753 0 mcast 65535 224.0.0.0/4 224.0.0.0 0 0 0 0 tunnel7 1500 192.168.7.0/24 192.168.7.135 0 0 0 0
3-2 APX 8000/MAX TNT/DSLTNT Administration Guide
Network Administration
Diagnostic tools for TCP/IP networks
Name MTU Net/Dest Address Ipkts Ierr Opkts Oerr vr0main 1500 192.168.7.135/32 192.168.7.135 0 0 0 0 sip0 65535 - - 0 0 0 0 wan10 1528 200.4.2.2 192.168.7.135 0 0 0 0 wan11 1528 200.5.2.2 192.168.7.135 0 0 0 0 wan12 1528 200.6.1.2 192.168.7.135 0 0 0 0 wan13 1528 200.6.2.2 192.168.7.135 0 0 0 0 wan14 1528 200.100.2.2 192.168.7.135 0 0 0 0 wan15 1528 200.100.3.2 192.168.7.135 0 0 0 0 wan16 1528 200.4.4.2 192.168.7.135 0 0 0 0 wan17 1500 200.6.100.2 200.1.100.2 0 0 0 0 wan18 1528 200.4.4.3 192.168.7.135 0 0 0 0 wan19 1528 200.4.2.3 192.168.7.135 0 0 0 0 wan20 1528 200.3.2.2 192.168.7.135 0 0 0 0 wan21 1528 200.3.1.2 192.168.7.135 0 0 0 0 wan22 1528 200.4.103.2 192.168.7.135 0 0 0 0 wan23 1500 200.4.101.3 200.2.101.2 0 0 0 0
..
..
..
ie1-5-1 1500 200.1.1.0/24 200.1.1.2 0 0 1 0 ie1-5-2 1500 200.1.2.0/24 200.1.2.2 0 0 1 0 ie1-5-3 1500 200.2.1.0/24 200.2.1.2 75837 0 75838 0 ie1-5-4 1500 200.2.2.0/24 200.2.2.2 0 0 1 0 ie1-5-5 1500 - - 0 0 0 0
APX 8000/MAX TNT/DSLTNT Administration Guide 3-3
Network Administration
Diagnostic tools for TCP/IP networks
The interface table contains the following information:
Column name
Name
MTU
Net/Dest
Address
Ipkts
Ierr
Opkts
Oerr
Description
Name of the interface:
• ie0-n
—The shelf-controller Ethernet interfaces.
• ie[shelf]-[slot]-[item] —The Ethernet interfaces for
Ethernet cards.
• lo0 —The loopback interface.
• rj0
—The reject interface, used in network summarization.
• bh0 —The blackhole interface, used in network summarization.
• wanN —A WAN connection, entered as it becomes active.
• wanabe
—An inactive RADIUS dialout profile.
• local —The local machine.
• mcast —The multicast interface, which represents the multicast forwarder for the entire class-D address space.
• tunnelN
—A pseudo-interface that is used only when the
TAOS unit is configured as an ATMP Router Home Agent. In that configuration, the TAOS unit creates a route for each registered Mobile Client. Regardless of how many tunnels the
Home Agent may terminate, there is always a single tunnel interface. (The number appended to the tunnel interface name is an internal number used by the system.)
(Maximum Transmission Unit) The maximum packet size allowed on the interface.
Network or the target host this interface can reach.
Address of this interface.
Number of packets received.
Number of packets that contain errors.
Number of packets transmitted.
Number of transmitted packets that contain errors.
3-4 APX 8000/MAX TNT/DSLTNT Administration Guide
Network Administration
Diagnostic tools for TCP/IP networks
Displaying and modifying IP routes
This section explains how to display the TAOS unit’s IP routing table. It also explains how to use the Netstat command to display the IP routing table and the IProute command to add or delete static routes. For complete information about configuring IP routing on the TAOS unit, see the APX 8000/MAX TNT/DSLTNT WAN, Routing, and Tunneling Configuration Guide.
Using the Netstat command to display the routing table
To display the routing table, enter the Netstat command with the
–r
argument, as in the following example: admin>
netstat -r
Destination Gateway IF Flg Pref Met Use Age
127.0.0.0/8 - bh0 CP 0 0 0 154417
127.0.0.1/32 - local CP 0 0 0 154417
127.0.0.2/32 - rj0 CP 0 0 0 154417
182.21.33.0/24 192.168.7.1 ie0 SG 60 8 0 150873
192.168.7.0/24 - ie0 C 0 0 50041 154417
192.168.7.135/32 - local CP 0 0 2522 154417
..
..
..
216.64.222.0/24 192.168.7.1 ie0 SG 60 8 1456 150873
224.0.0.0/4 - mcast CP 0 0 0 154417
224.0.0.1/32 - local CP 0 0 0 154417
224.0.0.2/32 - local CP 0 0 0 154417
224.0.0.5/32 - local CP 0 0 0 154417
224.0.0.6/32 - local CP 0 0 0 154417
224.0.0.9/32 - local CP 0 0 0 154417
255.255.255.255/32 - ie0 CP 0 0 0 154417
The columns in the routing table contain the following information:
Column Description
Destination
The route’s target address. To send a packet to this address, the TAOS unit uses this route. If the target address appears more than once in the routing table, the TAOS unit uses the most specific route (having the largest subnet mask) that matches that address.
Gateway
The next hop router that can forward packets to the given destination.
Direct routes (without a gateway) show a hyphen in this column.
APX 8000/MAX TNT/DSLTNT Administration Guide 3-5
Network Administration
Diagnostic tools for TCP/IP networks
Column
IF
Flg
Pref
Metric
Use
Age
Description
The name of the interface through which to send packets over this route:
• ie0
or ie[shelf]-[slot]-[item]
is an Ethernet interface.
• lo0
is the loopback interface.
• rj0
is the reject interface, used in network summarization.
• bh0
is the blackhole interface, used in network summarization.
• wanN
is a WAN connection, entered as it becomes active.
• wanabe
indicates an inactive RADIUS dialout profile.
• local
indicates a single route targeted at the local machine.
• mcast
indicates a route to a virtual device. The route encapsulates the multicast forwarder for the entire class D address space.
One or more of the following flags:
•
C
—a directly connected route, such as Ethernet
•
I
—an ICMP redirect dynamic route
•
N
—placed in the table via SNMP MIB II
•
O
—A route learned from OSPF
•
R
—a route learned from RIP
• r
—a transient RADIUS-like route
•
S
—a static route
•
?
—a route of unknown origin, which indicates an error
•
G
—an indirect route via a gateway
•
P
—a private route
•
T
—a temporary route
•
M
—a multipath route
•
*
—a backup static route for a transient RADIUS-like route
The preference value. See the description of the Preference parameter for information about defaults for route preferences.
A RIP-style metric for the route, with a range of 0-16. Routes learned from
OSPF show a RIP metric of 10. OSPF cost-infinity routes show a RIP metric of 16.
A count of the number of times the route was referenced since it was created. (Many of these references are internal, so this is not a count of the number of packets sent over this route.)
The age of the route in seconds. RIP and ICMP entries are aged once every
10 seconds.
Modifying the routing table
The IProute command enables you to manually add routes to the routing table, delete them, or change their preference or metric values. The command is useful for temporary routing changes. Changes you make to the routing table with the IProute command do not persist
3-6 APX 8000/MAX TNT/DSLTNT Administration Guide
Network Administration
Diagnostic tools for TCP/IP networks
across system resets. RIP and OSPF updates can add back any route you remove with IProute
Delete. Also, the TAOS unit restores all routes listed in the IP-Route profile after a system reset.
The IProute command uses the following syntax:
iproute option
Syntax element add delete
Description
Add an IP route to the routing table.
Delete an IP route from the routing table.
Adding a static IP route to the routing table
To add a static IP route to the TAOS unit’s routing table, use the IProute Add command:
iproute add
dest_IPaddr [/subnet_mask] gateway_IPaddr [/subnet_mask]
[
pref
] [
metric
]
Syntax element dest_IPaddr
[/
subnet_mask
]
gateway_IPaddr
[/
subnet_mask
]
pref metric
Description
Destination network address. The optional subnet mask specifies the number of bits in the mask. The default is 0.0.0.0/0. Note that the router uses the most specific route (having the largest mask) that matches a given destination.
IP address of the router that can forward packets to the destination network, and optional subnet mask (in bits). The default is 0.0.0.0.
Route preference. The default is 100.
Virtual hop count of the route. You can enter a value between 1 and 15. The default is 1. Note that RIP and OSPF updates can change the metric for any route, including one you have modified manually by using the IProute command.
For example, consider the following command: admin>
iproute add 10.1.2.0/24 10.0.0.3/24 1
It adds a route to the 10.1.2.0 network and all of its subnets, through the IP router located at
10.0.0.3/24. The metric to the route is 1 (one hop away).
If you try to add a route to a destination that is already in the routing table, the TAOS unit does not replace the existing route unless it has a higher metric than the route you attempt to add. If you get the message
Warning: a better route appears to exist
, the TAOS unit has rejected your attempt to add a route.
APX 8000/MAX TNT/DSLTNT Administration Guide 3-7
Network Administration
Diagnostic tools for TCP/IP networks
Deleting a static IP route from the routing table
To remove a static IP route from the TAOS unit’s routing table, enter the IProute Delete command:
iproute delete
dest_IPaddr[/subnet_mask][gateway_IPaddr[/subnet_mask]]
The arguments are the same as for IP Route Add. For example, the following command removes the route to the 10.1.2.0 network: admin>
iproute delete 10.1.2.0 10.0.0.3/24
You can also change the metric or preference value of an existing route by using the IProute command. For example, if the routing table contains the following route:
Destination Gateway IF Flg Pref Met Use Age
10.122.99.0/24 10.122.99.1 wan4 SG 100 7 0 48630
You could change the metric as follows: admin>
iproute add 10.122.99.0/24 10.122.99.1 50 3
Using the TraceRoute command to trace routes
The TraceRoute command is useful for locating slow routers or diagnosing IP routing problems. It traces the route an IP packet follows, by launching UDP probe packets with a low
Time-To-Live (TTL) value and then listening for an ICMP time exceeded
reply from a router. For example, to trace the route to the host techpubs : admin> traceroute techpubs traceroute to techpubs (10.65.212.19), 30 hops max, 0 byte packets
1 techpubs.eng.ascend.com (10.65.212.19) 0 ms 0 ms 0 ms
Probes start with a TTL of one and increase by one until of the following conditions occur:
• The TAOS unit receives an ICMP port unreachable
message. (The UDP port in the probe packets is set to an unlikely value, such as 33434, because the target host is not intended to process the packets. A port unreachable
message indicates that the packets reached the target host and were rejected.)
• The TTL value reaches the maximum value. (By default, the maximum TTL is set to 30.)
You can use the -m option to specify a different TTL. For example: admin> traceroute -m 60 techpubs traceroute to techpubs (10.65.212.19), 60 hops max, 0 byte packets
1 techpubs.eng.abc.com (10.65.212.19) 0 ms 0 ms 0 ms
TraceRoute sends three probes at each TTL setting. The second line of output shows the address of the router and the round trip time of each probe. If the probe answers come from different gateways, the address of each responding system is shown. If there is no response within a three-second timeout interval, the second line of output lists an asterisk.
For the details of the TraceRoute command, see the APX 8000/MAX TNT/DSLTNT Reference.
3-8 APX 8000/MAX TNT/DSLTNT Administration Guide
Network Administration
Diagnostic tools for TCP/IP networks
Using the NSlookup command to verify name service setup
You can retrieve a host address by using the NSlookup command, provided that the TAOS unit has been configured with the address of a name server. (For information about configuring name servers, see the APX 8000/MAX TNT/DSLTNT WAN, Routing, and Tunneling
Configuration Guide). If a host has several IP interfaces, the command returns several addresses.
To retrieve the IP address of the host techpubs
, proceed as in the following example: admin>
nslookup techpubs
Resolving host techpubs.
IP address for host techpubs is 10.65.212.19.
Using the ARPtable command to display the ARP cache
The Address Resolution Protocol (ARP) translates between IP addresses and media access control (MAC) addresses as defined in RFC 826. Hosts broadcast an ARP request that is received by all hosts on the local network, and the one host that recognizes its own IP address sends an ARP response with its MAC address.
The TAOS unit maintains a cache of known IP addresses and host MAC, addresses which enables it to act as a proxy for ARP requests for target hosts across the WAN, provided that proxy mode is turned on. (For configuring proxy ARP, see APX 8000/MAX TNT/DSLTNT
WAN, Routing, and Tunneling Configuration Guide.)
With the ARPtable command, you can display the ARP table, add or delete ARP table entries, or clear the ARP cache entirely. To display the ARP cache, enter the ARPtable command without any arguments, as in the following example: admin> arptable
IP Address MAC Address Type IF Retries/Pkts/RefCnt Time Stamp
10.103.0.141 00:B0:24:BE:D4:84 DYN 0 0/0/1 23323
10.103.0.2 00:C0:7B:7A:AC:54 DYN 0 0/0/599 23351
10.103.0.220 00:C0:7B:71:83:02 DYN 0 0/0/2843 23301
10.103.0.1 08:00:30:7B:24:27 DYN 0 0/0/4406 23352
10.103.0.8 00:00:0C:06:B3:A2 DYN 0 0/0/6640 23599
10.103.0.7 00:00:0C:56:57:4C DYN 0 0/0/6690 23676
10.103.0.49 00:B0:80:89:19:95 DYN 0 0/0/398 23674
The ARP table displays the following information:
Column
IP Address
MAC Address
Type
IF
Description
The address contained in ARP requests.
The MAC address of the host.
How the address was learned, that is, dynamically (DYN) or by specification of a static route (STAT).
The interface on which the TAOS unit received the ARP request.
APX 8000/MAX TNT/DSLTNT Administration Guide 3-9
Network Administration
Diagnostic tools for TCP/IP networks
Column
Retries
Pkts
Description
The number of retries needed to refresh the entry after it timed out.
The number of packets sent out to refresh the entry after it timed out.
To add an ARP table entry, use the
-a
option, as in the following example: admin> arptable -a 10.65.212.3 00:00:81:3D:F0:48
To delete an ARP table entry, use the -d option, as in the following example: admin> arptable -a 10.9.8.20
To clear the entire ARP table, use the
-f
option: admin> arptable -f
Displaying protocol statistics
The Netstat command displays the TAOS unit’s IP interface and routing tables, protocol statistics, and active sockets. By default (without an argument), the Netstat command reports information about both UDP and TCP. Following is an example that shows the use of Netstat without any arguments to display UDP and TCP socket information: admin> netstat udp:
-Socket- Local Port InQLen InQMax InQDrops Total Rx
1/c 0 1023 0 1 0 0
1/c 1 520 0 0 0 15510
1/c 2 7 0 32 0 0
1/c 3 123 0 32 0 0
1/c 4 5150 0 256 0 0
1/c 5 1022 0 128 0 0
1/c 6 161 0 32 0 0
1/c 7 1797 0 128 0 22
1/8 0 1018 0 128 0 0
1/8 1 20108 0 32 0 0
1/8 2 1008 0 128 0 0
1/8 3 1798 0 128 0 0
1/9 0 1021 0 128 0 0
1/9 1 20109 0 32 0 0
1/9 2 1009 0 128 0 0
1/9 3 1799 0 128 0 0
1/10 0 1020 0 128 0 0
1/10 1 20110 0 32 0 0
1/10 2 1010 0 128 0 0
1/10 3 1800 0 128 0 0
1/11 0 1017 0 128 0 0
1/11 1 20111 0 32 0 0
1/11 2 1011 0 128 0 0
1/11 3 1801 0 128 0 0
1/12 0 1019 0 128 0 0
3-10 APX 8000/MAX TNT/DSLTNT Administration Guide
Network Administration
Diagnostic tools for TCP/IP networks
1/12 1 20112 0 32 0 0
1/12 2 1012 0 128 0 0
1/12 3 1802 0 128 0 0 tcp:
-Socket- Local Remote State
1/c 0 192.168.7.135.79 *.* LISTEN
1/c 1 192.168.7.135.1723 *.* LISTEN
1/c 2 192.168.7.135.23 *.* LISTEN
1/c 4 192.168.7.135.23 172.20.32.137.42863 ESTABLISHED
1/c 9 192.168.7.135.23 206.65.212.10.1991 ESTABLISHED
The output shows the queue depth of various UDP ports, as well as the total packets received and total packets dropped on each port. The total-packets-received count includes the total packets dropped. For this sample output, the SNMP queue depth was set to 32. For information about queue depths, see the APX 8000/MAX TNT/DSLTNT WAN, Routing, and Tunneling
Configuration Guide.
The Netstat command supports the –s option, which displays protocol statistics. The –s option uses the following syntax:
netstat -s identifiers
If no identifiers follow the
–s
option, all protocol statistics are shown. If specified, the identifiers determine the type of protocol statistics to display. Valid identifiers include udp
, tcp
, icmp
, ip
, igmp
, or mcast
. Following is an example that displays all statistics: admin>
netstat -s
udp:
15636 packets received
0 packets received with no ports
0 packets received with errors
0 packets dropped
68 packets transmitted tcp:
0 active opens
7 passive opens
0 connect attempts failed
0 connections were reset
2 connections currently established
1457 segments received
0 segments received out of order
1728 segments transmitted
18 segments retransmitted
5 active closes
0 passive closes
0 disconnects while awaiting retransmission icmp:
216 packets received
0 packets received with errors
Input histogram:
216 echo requests
APX 8000/MAX TNT/DSLTNT Administration Guide 3-11
Network Administration
Diagnostic tools for TCP/IP networks
271 packets transmitted
0 packets not transmitted due to lack of resources
Output histogram:
216 echo replies
24 destination unreachable
31 time exceeded ip:
28860 packets received
0 packets received with header errors
0 packets received with address errors
0 packets received forwarded
0 packets received with unknown protocols
0 inbound packets discarded
17310 packets delivered to upper layers
2084 transmit requests
0 discarded transmit packets
49 outbound packets with no route
0 reassemblies timeout
268 reassemblies required
12 reassemblies succeeded
244 reassemblies failed
12 fragmentation succeeded
0 fragmentation failed
24 fragmented packets created
0 route discards due to lack of memory
64 default ttl igmp:
0 packets received
0 bad checksum packets received
0 bad version packets received
0 query packets received
0 leave packets received
0 packets transmitted
0 query packets sent
0 response packets sent
0 leave packets sent mcast:
0 packets received
0 packets forwarded
0 packets in error
0 packets dropped
0 packets transmitted
3-12 APX 8000/MAX TNT/DSLTNT Administration Guide
Network Administration
Diagnostic tools for TCP/IP networks
Logging into a network host
The Rlogin and Telnet commands enable you to log into a network host from the TAOS unit.
Using the Rlogin command
The Rlogin command initiates a login session from a host card, such as a modem or HDLC card, to a remote host. For example, to log into the host techpubs
, first open a session with the host card. Then issue the Rlogin command: hdlc-1/16> rlogin techpub
s
Password:
Last login: Wed Oct 2 10:31:36 from marcel.marceau
SunOS Release 4.1.4 (TECHPUBS-BQE) #1: Wed Jan 4 08:56:59
PDT 2000 techpubs%
You can log out of the remote host by entering the Rlogin escape sequence (tilde-dot): techpubs% ~.
Connection closed.
Or, you can log out explicitly: techpubs% logout
Connection closed.
If you wish, you can change the default escape character from a tilde to any other character.
For details, see the APX 8000/MAX TNT/DSLTNT Reference.
If your user name on the TAOS unit is different from your user name on the remote host, you can specify a user name on the Rlogin command line. For example: admin> rlogin -l marcel techpubs
Password:
Using the Telnet command
The Telnet command initiates a login session to a remote host. For example, to Telnet into the host techpubs : admin> telnet techpubs
Connecting to techpubs (10.65.212.19) ...
Escape character is ’^]’
Connected
SunOS UNIX (techpubs)
You can close the Telnet session by logging out of the remote host: techpubs% logout
Connection closed.
APX 8000/MAX TNT/DSLTNT Administration Guide 3-13
Network Administration
Diagnostic tools for TCP/IP networks
Pattern detection and reporting in the TCP-Clear data stream
You can run the Tokencount diagnostic command to detect and report the number of instances of a specified pattern (a token) in the TCP-Clear data stream sent by the TAOS. On the shelf controller, the command enables or disables the token-counting process, specifies up to four patterns, clears counters, and displays token information system-wide. Updates to the command specified on the shelf controller are immediately propagated to the host cards.
Note:
Running the token-counting process incurs a substantial system performance penalty.
When token-counting is enabled, the system scans all outbound data sent to TCP-Clear sessions for a specified pattern, and increments a counter for each match. If the system resets, it loses the token information.
Tokencount command syntax
On the shelf controller, the Tokencount command supports the following syntax: usage: tokencount -option [ params ]
-a clear counter for (a)ll tokens
-c n (c)lear counter for nth token
-d (d)isable token counting in the TCP-CLEAR buffer
-e (e)nable token counting in the TCP-CLEAR buffer
-i display counter (i)nfo
-u n pattern (u)pdate type nth token pattern
-? display this summary
Option
-a
-c n
-d
-e
-i
-u n
Description
Set token counters to zero. If the system resets, all token counters are set to zero. If a card resets, counters on that card are set to zero.
Set the counter for the specified token to zero.
Disable the token-counting process.
Enable the token-counting process.
Display the current token search information, including the number found of each defined token.
Define a search token pattern and assign it the specified number.
Each pattern can contain up to 20 characters, but the first specified character cannot be repeated in the pattern more than eight times. You can specify the pattern as a combination of alphanumeric, hexadecimal, octal, and special characters, but output on the host is always in hexadecimal format. The following special characters are significant when specifying the pattern:
Characters
\x##
\##
\a
\b
Meaning
Hex format
Octal format
Alarm
Backspace
ASCII value
N/A. To insert a 2-digit hexadecimal number in the pattern, precede the number with
\x
.
N/A. To insert a 2-digit octal number, precede the number with a backslash.
7
8
3-14 APX 8000/MAX TNT/DSLTNT Administration Guide
Network Administration
Diagnostic tools for TCP/IP networks
Characters
\f
\\
\"
\’
\n
\r
\t
\v
Meaning
Form feed
Newline
Return
Tab
Vertical tab
Backslash
Quotation mark
Apostrophe
ASCII value
11
92
34
44
12
10
13
9
Examples of using Tokencount
The following commands enable the token-counting process and define four token patterns: admin> tokencount -e admin> tokencount -u 1 \xB0\x35\xFF\x10\x01 admin> tokencount -u 2 LC\n admin> tokencount -u 3 A1\12\15 admin> tokencount -u 4 \a\b\f\n\r\t\v\\\’\" admin> tokencount -i
Tokencount is enabled
Number of "\xB0\x35\xFF\x10\x01" token received:0
Number of "LC\n" token received:0
Number of "A1\12\15" token received:0
Number of "\a\b\f\n\r\t\v\\\’\"" token received:0
The next commands open a session with a modem card in shelf 5, slot 6 and display the token information gathered on that card: admin> open 5 6 csm3-5/6> tokencount
Tokencount is enabled
"0xb00x350xff0x100x1" token received:0
"0x4c0x430xa" token received:0
"0x410x310xa0xd" token received:0
"0x70x80xc0xa0xd0x90xb0x5c0x270x22" received:0
Tokencount error messages
When Tokencount is enabled, it can generate the following error messages: error: token type index must be in the range of 1 to 4
The number specified in the Tokencount -u command is out of the valid range from 1 to 4.
error: max. token size is 20
More than 20 characters were specified as a pattern in the Tokencount -u command.
error: wrong token type index
The character immediately following Tokencount -u was not numeric.
APX 8000/MAX TNT/DSLTNT Administration Guide 3-15
Network Administration
Diagnostic tools for IGMP multicast interfaces
Diagnostic tools for IGMP multicast interfaces
The IGMP command displays information about IGMP groups and clients. This can be useful for tracking the IGMP group memberships and active client interfaces.
Displaying IGMP group information
To display active multicast group addresses and clients (interfaces) registered for each group, enter the IGMP command with the group option: admin>
igmp group
IGMP Group address Routing Table Up Time: 0:0:22:17
Hash Group Address Members Expire time Counts
10 224.0.2.250
2 0:3:24 3211 :: 0 S5
1 0:3:21 145 :: 0 S5
0(Mbone) ...... 31901 :: 0 S5
The output contains the following fields:
Field
Hash
Group address
Members
Expire time
Counts
Description
Index to a hash table (displayed for debugging purposes only).
IP multicast address used for the group. An asterisk indicates the IP multicast address being monitored, meaning that members join this address by local application.
ID of each member of each multicast group. The zero ID represents members on the same Ethernet interface as the TAOS unit. All other
IDs go to members of each group as they inform the TAOS unit that they have joined the group. If a client is a member of more than one group to which the TAOS unit forwards multicast packets, it has more than one multicast ID.
When this membership expires. The TAOS unit sends out IGMP queries every 60 seconds, so the expiration time is usually renewed.
If the expiration time is reached, the TAOS unit removes the entry from the table. If the field contains periods, this membership never expires.
Number of packets forwarded to the client, number of packets dropped due to lack of resources, and the state of the membership.
The state is displayed for debugging purposes.
3-16 APX 8000/MAX TNT/DSLTNT Administration Guide
Network Administration
Diagnostic tools for IGMP multicast interfaces
Displaying IGMP client information
To display a list of multicast clients, enter the IGMP command with the client
option: admin>
igmp client
IGMP Clients
Client Version RecvCount CLU ALU
0(Mbone) 1 0 0 0
2 1 39 68 67
1 1 33310 65 65
The output contains the following fields:
Field
Client
Version
RecvCount
CLU
ALU
Description
ID of the interface on which the client resides. The value 0 (zero) represents the Ethernet. Other numbers are WAN interfaces, numbered according to when they became active.
Mbone
is the interface on which the multicast router resides.
Version of IGMP being used.
Number of IGMP messages received on the client’s interface.
Current Line Utilization and Average Line Utilization. Both indicate the percentage of bandwidth utilized across this interface. If bandwidth utilization is high, some IGMP packet types are not forwarded.
APX 8000/MAX TNT/DSLTNT Administration Guide 3-17
Network Administration
Diagnostic tools for OSPF routers
Diagnostic tools for OSPF routers
The OSPF diagnostic-level commands enable the administrator to display information related to OSPF routing, including the link state advertisements (LSAs), border routers’ routing table, and the OSPF areas, interfaces, statistics, and routing table. To display the usage statement, enter the OSPF command with the
?
option: admin> ospf ospf ? OSPF help information ospf size OSPF size ospf areas OSPF areas ospf stats OSPF statistics ospf intf [ip-address] OSPF summary/detail interface information ospf lsa area ls-type ls-id ls-orig OSPF detail link-state advertisement ospf lsdb [area] OSPF link-state DB summary for an ospf nbrs [neighbor-id] OSPF summary/detail neighbor information ospf routers OSPF routers ospf ext OSPF external AS advertisements ospf rtab OSPF routing table ospf database OSPF entire database summary ospf internal OSPF internal routes
Displaying general information about OSPF routing
To display general information about OSPF, enter the OSPF command with the stat option.
For example: admin> ospf stats
OSPF version: 2
OSPF Router ID: 10.103.0.254
AS boundary capability: Yes
Attached areas: 1 Estimated # ext. (5) routes: 65536
OSPF packets rcvd: 71788 OSPF packets rcvd w/errs: 19
Transit nodes allocated: 812 Transit nodes freed: 788
LS adv. allocated: 2870 LS adv. freed: 2827
Queue headers alloc: 64 Queue headers avail: 64
# Dijkstra runs: 10 Incremental summ. updates: 0
Incremental VL udates: 0 Buffer alloc failures: 0
Multicast pkts sent: 27343 Unicast pkts sent: 1154
LS adv. aged out: 0 LS adv. flushed: 507
Incremental ext.(5) updates: 1014 Incremental ext.(7) updates: 0
3-18 APX 8000/MAX TNT/DSLTNT Administration Guide
Network Administration
Diagnostic tools for OSPF routers
External (Type 5) LSA database -
Current state: Normal
Number of LSAs: 43
Number of overflows: 0
The following table describes the output:
Field Specifies
OSPF version
OSPF Router ID
Version of the OSPF protocols running.
IP address assigned to the TAOS unit, which is typically the address specified for the Ethernet interface.
AS boundary capability
Yes if the TAOS unit functions as an ASBR or No if it does not function as an ASBR.
Number of areas to which this TAOS unit attaches.
Attached areas
Estimated # ext.(5) routes
Number of ASE-5 routes that the TAOS unit can maintain before it goes into an overload state.
OSPF packets rcvd
OSPF packets rcvd w/ errs
Total number of OSPF packets received by the TAOS unit.
Total number of OSPF errored packets received by the TAOS unit.
Transit nodes allocated
LS adv. freed
Allocated transit nodes generated only by Router LSAs (Type
1) and Network LSAs (Type 2).
Transit nodes freed
Freed transit nodes generated only by Router LSAs (Type 1) and Network LSAs (Type 2).
Number of LSAs freed.
Queue headers alloc
Number of queue headers allocated. LSAs can reside in multiple queues. Queue headers are the elements of the queues that contain the pointer to the LSA.
Queue headers avail
Available memory for queue headers. To prevent memory fragmentation, the TAOS unit allocates memory in blocks.
The TAOS unit allocates queue headers from the memory blocks. When the TAOS unit frees all queue headers from a specific memory block, the TAOS unit returns the block to the pool of available memory blocks.
# Dijkstra runs
Incremental summ. updates
Incremental VL updates
Buffer alloc failures
Number of times that the TAOS unit has run the Dijkstra algorithm (short path computation).
Number of summary updates that the TAOS unit runs when small changes cause generation of Summary LSAs (Type 3) and Summary Router LSAs (Type 4).
Number of incremental virtual link updates that the TAOS unit performs.
Number of buffer allocation problems that the TAOS unit has detected and from which it has recovered.
APX 8000/MAX TNT/DSLTNT Administration Guide 3-19
Network Administration
Diagnostic tools for OSPF routers
Field Specifies
Multicast pkts sent
Number of multicast packets sent by OSPF.
Unicast pkts sent
Number of unicast packets sent by OSPF.
LS adv. aged out
Number of LSAs that the TAOS unit has aged and removed from its tables.
Number of LSAs that the TAOS unit has flushed.
LS adv. flushed
Incremental ext.(5) updates
Number of incremental ASE-5 updates.
Incremental ext.(7) updates
Number of incremental ASE-7 updates.
Current state
State of t he External (Type-5) LSA database: Normal or
Overload.
Number of LSAs
Number of LSAs in the External (Type-5) LSA database.
Number of overflows
Number of ASE-5s that exceeded the limit of the database.
Displaying the OSPF database
To display the entire OSPF database, enter the OSPF command with the database option.
For example: admin>
ospf database
Router Link States (Area: 0.0.0.0)
Type LS ID LS originator Seqno Age Xsum
RTR 10.101.0.1 10.101.0.1 0x800002a1 746 0x8bd8
RTR 10.101.0.2 10.101.0.2 0x800002d6 539 0x0ea1
RTR 10.102.0.1 10.102.0.1 0x800002a3 2592 0x9bc1
RTR 10.103.0.204 10.103.0.204 0x800001ba 1173 0x725f
RTR 10.103.0.254 10.103.0.254 0x80000301 534 0x7066
RTR 10.104.0.1 10.104.0.1 0x800002ad 777 0xb98e
RTR 10.104.0.2 10.104.0.2 0x80000193 1258 0x265a
RTR 10.105.0.2 10.105.0.2 0x80000299 865 0x4295
RTR 10.105.0.3 10.105.0.3 0x800002e5 1057 0x4449
RTR 10.105.0.4 10.105.0.4 0x80000310 1585 0x5775
RTR 10.105.0.61 10.105.0.61 0x800002ae 1204 0xcf2e
RTR 10.105.0.200 10.105.0.200 0x80000263 213 0x4b25
RTR 10.123.0.8 10.123.0.8 0x80000401 1071 0xecf2
RTR 10.123.0.254 10.123.0.254 0x80000401 1175 0xad39
RTR 12.151.0.2 12.151.0.2 0x800006ee 825 0x0531
RTR 192.1.1.1 192.1.1.1 0x8000039b 18 0xb04b
RTR 210.210.210.1 210.210.210.1 0x800001aa 201 0x5338
# advertisements: 17
Checksum total: 0x7946c
Network Link States (Area: 0.0.0.0)
Type LS ID LS originator Seqno Age Xsum
NET 10.101.0.1 10.101.0.1 0x80000236 746 0x1d45
NET 10.102.0.1 10.102.0.1 0x80000235 2592 0x1f40
3-20 APX 8000/MAX TNT/DSLTNT Administration Guide
Network Administration
Diagnostic tools for OSPF routers
NET 10.104.0.2 10.104.0.2 0x80000179 830 0x67a8
NET 10.105.0.8 10.123.0.8 0x80000304 1071 0x0ccd
NET 10.123.0.6 12.151.0.2 0x8000023d 825 0x59ed
NET 100.103.100.204 10.103.0.204 0x80000029 252 0x8b34
# advertisements: 6
Checksum total: 0x1961b
External ASE5 Link States
Type LS ID LS originator Seqno Age Xsum
ASE5 10.103.1.0 10.103.0.204 0x8000004f 1726 0xd23f
ASE5 10.103.2.0 10.103.0.204 0x8000004f 1716 0xc749
ASE5 10.103.3.0 10.103.0.204 0x8000004f 1704 0xbc53
ASE5 10.103.4.0 10.103.0.204 0x8000004f 1692 0xb15d
ASE5 10.103.6.0 10.103.0.204 0x8000004f 1672 0x9b71
ASE5 10.103.7.0 10.103.0.204 0x8000004f 1666 0x907b
ASE5 10.103.8.0 10.103.0.204 0x8000004f 1641 0x8585
ASE5 10.107.0.0 10.103.0.254 0x80000104 250 0x1413
ASE5 10.113.0.0 10.103.0.254 0x80000121 250 0x0e76
ASE5 10.200.0.2 10.103.0.254 0x80000001 231 0xa823
ASE5 10.222.0.2 10.103.0.254 0x80000001 202 0x9f16
ASE5 11.0.0.0 10.103.0.254 0x80000027 250 0x49a6
ASE5 11.103.0.0 10.103.0.254 0x80000121 250 0xfc10
ASE5 14.240.0.0 10.103.0.204 0x800001a4 199 0x0926
ASE5 50.151.0.2 10.103.0.254 0x80000121 250 0xa90a
ASE5 101.103.0.0 10.103.0.254 0x80000121 250 0x664c
..
..
# advertisements: 44
Checksum total: 0x191d3a
The following table describes the output:
Field
Type
LS ID
LS originator
Specifies
Type of link as defined in RFC 1583:
• Type 1 (RTR) are router-LSAs that describe the collected states of the router’s interfaces.
• Type 2 (NET) are network-LSAs that describe the set of routers attached to the network.
• Types 3 and 4 (SUM) describe routes to networks in remote areas or AS boundary routers.
• Type 5 (ASE) are AS-external-LSAs that describe routes to destinations external to the Autonomous System. A default route for the Autonomous System can also be described by an
AS-external-LSA. The ext
option only displays ASE5 LSAs.
• Type 7 are ASE-7 link advertisements that are only flooded within an NSSA.
Target address of the route.
Address of the advertising router.
APX 8000/MAX TNT/DSLTNT Administration Guide 3-21
Network Administration
Diagnostic tools for OSPF routers
Field Specifies
Seqno
Checksum total
Hexadecimal number that begins with 80000000 and increments by one for each LSA received.
Age
Xsum
Age of the route in seconds.
Checksum of the LSA.
# advertisements
Total number of entries in the database.
Checksum of the database.
Displaying OSPF external AS advertisements
To display only OSPF External AS advertisements, include the ext
option with the OSPF command. For example: admin>
ospf ext
Type LS ID LS originator Seqno Age Xsum
ASE5 10.103.1.0 10.103.0.204 0x8000004f 1702 0xd23f
ASE5 10.103.2.0 10.103.0.204 0x8000004f 1692 0xc749
ASE5 10.103.3.0 10.103.0.204 0x8000004f 1680 0xbc53
ASE5 10.103.4.0 10.103.0.204 0x8000004f 1668 0xb15d
ASE5 10.103.6.0 10.103.0.204 0x8000004f 1648 0x9b71
ASE5 10.103.7.0 10.103.0.204 0x8000004f 1642 0x907b
ASE5 10.103.8.0 10.103.0.204 0x8000004f 1617 0x8585
..
..
ASE5 214.240.0.127 10.103.0.204 0x800001a4 175 0xdb0b
ASE5 223.57.40.0 10.103.0.254 0x80000121 226 0x7540
ASE5 223.57.40.244 10.103.0.254 0x80000121 226 0xe3dc
# advertisements: 46
Checksum total: 0x1a1d9e
The output of this command is the same as for the OSPF database command, with the exception of the Type. The OSPF Ext command only shows ASE5 type LSAs.
Displaying OSPF internal AS advertisements
To display OSPF internal AS advertisements, include the internal option with the OSPF command. For example: admin>
ospf internal
Area: 0.0.0.1
Destination Mask Cost
33.240.0.0 255.255.255.224 1
103.240.0.0 255.255.255.192 1
113.240.0.0 255.255.255.128 1
183.240.0.0 255.255.255.128 1
193.240.0.0 255.255.255.128 1
203.240.0.0 255.255.255.128 1
3-22 APX 8000/MAX TNT/DSLTNT Administration Guide
Network Administration
Diagnostic tools for OSPF routers
The following table describes the output:
Field
Area
Destination
Mask
Cost
Specifies
Area in which the router resides.
The route’s target address. To send a packet to this address, the TAOS unit uses this route. If the target address appears more than once in the routing table, the TAOS unit uses the most specific route (having the largest subnet mask) that matches that address.
Subnet mask of the route.
Cost of the router.
Displaying the OSPF link-state database
To display the link-state database for the first configured area (or for the only defined area), include the lsdb option with the OSPF command. The TAOS unit does not currently operate as an ABR, so each TAOS unit’s OSPF interface belongs to the same area. (That area number does not have to be the default backbone area 0.0.0.0.)
For example: admin>
ospf lsdb
Area: 0.0.0.0
Type LS ID LS originator Seqno Age Xsum
RTR 10.101.0.1 10.101.0.1 0x8000029f 720 0x8fd6
RTR 10.101.0.2 10.101.0.2 0x800002d1 126 0x189c
RTR 10.102.0.1 10.102.0.1 0x800002a2 767 0x9dc0
RTR 10.102.0.2 10.102.0.2 0x800002cc 124 0x862c
RTR 10.103.0.204 10.103.0.204 0x800001b8 1147 0x765d
RTR 10.103.0.254 10.103.0.254 0x800002fb 167 0x8cc9
RTR 10.104.0.1 10.104.0.1 0x800002ab 751 0xbd8c
RTR 10.104.0.2 10.104.0.2 0x80000191 1232 0x2a58
RTR 10.105.0.2 10.105.0.2 0x80000297 843 0x4693
RTR 10.105.0.3 10.105.0.3 0x800002e3 1032 0x4847
RTR 10.105.0.4 10.105.0.4 0x8000030e 1560 0x5b73
RTR 10.105.0.61 10.105.0.61 0x800002ac 1178 0xd32c
RTR 10.105.0.200 10.105.0.200 0x80000261 194 0x4f23
RTR 10.123.0.8 10.123.0.8 0x800003ff 1045 0xf1ef
RTR 10.123.0.254 10.123.0.254 0x800003ff 1149 0xb236
RTR 12.151.0.2 12.151.0.2 0x800006ec 799 0x092f
RTR 192.1.1.1 192.1.1.1 0x80000398 1791 0xb648
RTR 210.210.210.1 210.210.210.1 0x800001a8 175 0x5736
NET 10.101.0.1 10.101.0.1 0x80000234 720 0x2143
NET 10.102.0.1 10.102.0.1 0x80000234 767 0x213f
NET 10.104.0.2 10.104.0.2 0x80000177 804 0x6ba6
NET 10.105.0.8 10.123.0.8 0x80000302 1045 0x10cb
NET 10.123.0.6 12.151.0.2 0x8000023b 799 0x5deb
NET 100.103.100.204 10.103.0.204 0x80000027 226 0x8f32
# advertisements: 24
Checksum total: 0xa2ae6
APX 8000/MAX TNT/DSLTNT Administration Guide 3-23
Network Administration
Diagnostic tools for OSPF routers
The fields in the output contain the following information:
Field Specifies
Area
Type
Area ID.
Indicates the type of link as defined in RFC 1583:
• Type 1 (RTR) are router-LSAs that describe the collected states of the router’s interfaces.
• Type 2 (NET) are network-LSAs that describe the set of routers attached to the network.
• Types 3 and 4 (SUM) describe routes to networks in remote areas or AS boundary routers.
• Type 7 are ASE-7 link advertisements that are only flooded within an NSSA.
LS ID
Specifies the target address of the route.
LS originator
Specifies the address of the advertising router.
Seqno
Indicates a hexadecimal number that begins with 80000000 and increments by one for each LSA received.
Age
Xsum
Specifies the age of the route in seconds.
Indicates the checksum of the LSA.
advertisements
Specifies the total number of entries in the link-state database.
Checksum total
Indicates the checksum of the link-state database.
You can expand each entry in the link-state database to view additional information about a particular LSA, as explained in the next section.
Displaying OSPF link-state advertisements
To view detailed information about a link-state advertisement, use the following format for the
OSPF command: ospf lsa area ls-type ls-id ls-orig
The command requires that you include the first four fields of the LSA as listed in the database. You can select the first four fields and paste them in after typing the command. For example, to show an expanded view of the last entry in the link-state database shown in the previous section: admin> ospf lsa 0.0.0.0 ase 10.5.2.160 10.5.2.162
LSA type: ASE ls id: 10.5.2.160 adv rtr: 110.5.2.162 age: 568 seq #: 80000037 cksum: 0xfffa
Net mask: 255.255.255.255 Tos 0 metric: 10 E type: 1
Forwarding Address: 0.0.0.0 Tag: c0000000
The output differs depending on the type of link. The following is an example of a router LSA: admin> ospf lsa 0.0.0.0 rtr 192.1.1.1 192.1.1.1
3-24 APX 8000/MAX TNT/DSLTNT Administration Guide
Network Administration
Diagnostic tools for OSPF routers
LS age: 66
LS options: (0x2) E
LS type: 1
LS ID (destination): 192.1.1.1
LS originator: 192.1.1.1
LS sequence no: 0x80000399
LS checksum: 0xb449
LS length: 48
Router type: (0x2) ASBR
# router ifcs: 2
Link ID: 10.105.0.8
Link Data: 10.105.0.7
Interface type: (2) TrnsNetwork
No. of metrics: 0
TOS 0 metric: 10 (0)
Link ID: 10.123.0.6
Link Data: 10.123.0.7
Interface type: (2) TrnsNetwork
No. of metrics: 0
TOS 0 metric: 10 (0)
The next example is for a network LSA: admin> ospf lsa 0.0.0.0 net 100.103.100.204 10.103.0.204
LS age: 814
LS options: (0x2) E
LS type: 2
LS ID (destination): 100.103.100.204
LS originator: 10.103.0.204
LS sequence no: 0x80000027
LS checksum: 0x8f32
LS length: 36
Network mask: 255.255.0.0
Attached Router: 10.103.0.204 (1)
Attached Router: 10.103.0.254 (1)
Attached Router: 10.123.0.254 (1)
For information about the fields in the output of these commands, see the APX 8000/MAX
TNT/DSLTNT Reference or RFC 1583.
Displaying the OSPF routing table
To display the OSPF routing table, include the rtab option with the OSPF command. For example: admin>
ospf rtab
DTyp RType Destination Area Cost Flags Next hop(s)
IfNum
RTE FIX 50.151.0.2/32 - 1 0x81 0.0.0.6
6
RTE FIX 130.57.40.243/32 - 10 0x1 0.0.0.6
6
RTE FIX 130.57.0.0/16 - 10 0x2 0.0.0.6
APX 8000/MAX TNT/DSLTNT Administration Guide 3-25
Network Administration
Diagnostic tools for OSPF routers
6
RTE FIX 140.57.40.244/32 - 10 0x1 0.0.0.6
6
RTE FIX 140.57.0.0/16 - 10 0x2 0.0.0.6
6
RTE FIX 150.57.40.245/32 - 10 0x1 0.0.0.6
6
RTE FIX 150.57.0.0/16 - 10 0x2 0.0.0.6
6
RTE FIX 160.57.40.246/32 - 10 0x1 0.0.0.6
6
RTE FIX 160.57.0.0/16 - 10 0x2 0.0.0.6
6
..
..
..
The fields in the output contain the following information:
Field
DType
RType
Destination
Area
Cost
Flags
Next hop(s)
#
Specifies
Internal route type. DType displays one of the following values: RTE
(generic route), ASBR (AS border route), or BR (area border route).
Internal router type. RType displays one of the following values: FIX
(static route), NONE, DEL (deleted or bogus state), OSPF
(OSPF-computed), OSE1 (type 1 external), or OSE2 (type 2 external).
Destination address and subnet mask of the route.
Area ID of the route.
Cost of the route.
Hexadecimal number representing an internal flag.
Next hop in the route to the destination.
Number of the interface used to reach the destination.
The fields in the output contain the following information:
Field
LSA type ls id adv rtr age seq # cksum
Specifies
Type of Link-State Advertisement.
Target address of the router.
Address of the advertising router.
Age of the route in seconds.
Number that begins with 80000000 and increments by one for each
LSA received.
Checksum for the LSA.
3-26 APX 8000/MAX TNT/DSLTNT Administration Guide
Network Administration
Diagnostic tools for OSPF routers
Field
Net mask
Tos metric
E type
Forwarding
Address
Tag
Specifies
Subnet mask of the LSA.
Type of Service for the LSA.
Cost of the link, not of a route. The cost of a route is the sum of all intervening links, including the cost of the connected route.
External type of the LSA indicating either 1 (Type 1) or 2 (Type 2)
Forwarding Address of the LSA (described in RFC 1583).
Tag of the LSA (described in RFC 1583).
Displaying information about OSPF areas
To display information about OSPF areas, include the areas
option with the OSPF command. For example: admin> ospf areas
Area ID Authentication Area Type #ifcs #nets #rtrs #brdrs #intnr
0.0.0.0
Simple-passwd Normal 1 0 2 0 3
The fields in the output contain the following information:
Field
Area ID
Authentication
Area Type
#ifcs
#nets
#rtrs
#brdrs
#intnr
Specifies
Area number in dotted-decimal format.
Type of authentication: Simple-passwd, MD5, or Null.
Type of OSPF area: Normal, Stub, or NSSA.
Number of TAOS unit interfaces specified in the area.
Number of reachable networks in the area.
Number of reachable routers in the area.
Number of reachable area border routers in the area.
Number of reachable internal routers in the area.
Displaying information about OSPF routers
To display OSPF routers, include the routers option with the OSPF command. For example: admin>
ospf routers
DType RType Destination Area Cost Next hop(s) IfNum
ASBR OSPF 10.101.0.1 0.0.0.0 11 10.101.0.2 20
ASBR OSPF 10.101.0.2 0.0.0.0 10 10.101.0.2 20
ASBR OSPF 10.103.0.204 0.0.0.0 1 100.103.100.204 24
ASBR OSPF 10.104.0.1 0.0.0.0 12 10.105.0.4 21
10.105.0.61 21
ASBR OSPF 10.104.0.2 0.0.0.0 11 10.105.0.4 21
APX 8000/MAX TNT/DSLTNT Administration Guide 3-27
Network Administration
Diagnostic tools for OSPF routers
10.105.0.61 21
BR OSPF 10.105.0.2 0.0.0.0 1 10.105.0.2 21
ASBR OSPF 10.105.0.2 0.0.0.0 1 10.105.0.2 21
ASBR OSPF 10.105.0.3 0.0.0.0 1 10.105.0.3 21
ASBR OSPF 10.105.0.4 0.0.0.0 1 10.105.0.4 21
ASBR OSPF 10.105.0.61 0.0.0.0 1 10.105.0.61 21
ASBR OSPF 10.105.0.200 0.0.0.0 1 10.105.0.200 21
ASBR OSPF 10.123.0.8 0.0.0.0 1 10.105.0.8 21
ASBR OSPF 10.123.0.254 0.0.0.0 1 100.103.100.123 24
BR OSPF 12.151.0.2 0.0.0.0 1 10.105.0.6 21
ASBR OSPF 192.1.1.1 0.0.0.0 1 10.105.0.7 21
The fields in the output contain the following information:
Field
DType
RType
Destination
Area
Cost
Next hop(s)
IfNum
Specifies
Internal route type. DType displays one of the following values: RTE
(generic route), ASBR (AS border route), or BR (area border route).
Internal router type.
Router’s IP address.
Area in which the router resides.
Cost of the router.
Next hop in the route to the destination.
Number of the interface used to reach the destination.
Displaying OSPF interfaces
To display summarized information about all OSPF interfaces or specific information about a single interface, include the intf option with the OSPF command.
Displaying summarized information
To display summarized information on OSPF interfaces, enter the following command: admin> ospf intf
Ifc Address Phys Assoc. Area Type State #nbrs #adjs DInt
10.103.0.254 ie0 0.0.0.0 Brdcst DR 0 0 40
10.105.0.254 ie1-7-1 0.0.0.0 Brdcst Other 9 1 40
100.103.100.254 ie1-7-4 0.0.0.0 Brdcst Other 2 2 40
50.151.0.2 apx1 0.0.0.0 P-P P-P 0 0 120
10.103.0.254 m2 0.0.0.0 P-P P-P 1 1 120
10.103.0.254 m1 0.0.0.0 P-P
P-P 1 1 120
3-28 APX 8000/MAX TNT/DSLTNT Administration Guide
Network Administration
Diagnostic tools for OSPF routers
The fields in the output contain the following information:
Field
Ifc Address
Phys
Assoc. Area
Type
State
#nbrs
#adjs
DInt
Specifies
Address assigned to the TAOS unit’s Ethernet interface. To identify
WAN links, use the Type and Cost fields.
Name of the interface or the Connection profile for WAN links.
Area in which the interface resides.
Point-to-Point (P-P) or Broadcast (Brdcst). WAN links are P-P links.
State of the link according to RFC 1583. There are many possible states, and not all states apply to all interfaces.
Number of neighbors of the interface.
Number of adjacencies on the interface.
Number of seconds that the TAOS unit waits for a router update before removing the router’s entry from its table. The interval is called the Dead Interval.
Displaying specific information about a specific interface
To display detailed information for a specific interface, enter the following command: admin>
ospf intf
interface-address
For example: admin> ospf intf 194.194.194.2
Interface address: 194.194.194.2
Attached area: 0.0.0.0
Physical interface: phani (wan1)
Interface mask: 255.255.255.255
Interface type: P-P
State: (0x8) P-P
Designated Router: 0.0.0.0
DR Priority:
Dead interval:
Backup DR: 0.0.0.0
Remote Address: 194.194.194.3
5 Hello interval: 30
120 TX delay: 1
Rxmt interval:
Poll interval:
5
0
Max pkt size: 1500 TOS 0 cost:
# Neighbors: 1 # Adjacencies:
10
1
# Mcast floods: 1856 # Mcast acks: 1855
# Full adjs.: 1
The fields in the output contain the following information:
Field
Interface Address
Attached Area
Physical interface
Specifies
IP address specified for the TAOS unit’s Ethernet interface.
Area in which the interface resides.
Name of the interface or the Connection profile for WAN links.
APX 8000/MAX TNT/DSLTNT Administration Guide 3-29
Network Administration
Diagnostic tools for OSPF routers
Field
Interface type
State
Designated Router
Backup DR
Remote Address
DR Priority
Hello interval
Rxmt interval
Dead interval
TX delay
Poll interval
Max pkt size
TOS 0 Count
# neighbors
# adjacencies
# Full adjs.
# Mcast floods
# Mcast acks
Specifies
Point-to-Point (P-P) or Broadcast (Bcast). WAN links are P-P links.
State of the link according to RFC 1583. There are many possible states, and not all states apply to all interfaces.
IP address of the designated router for the interface.
IP address of the backup designated router for the interface.
IP address of the remote end of a Point to Point (WAN) link.
Priority of the designated router.
Interval in seconds that the TAOS unit sends Hello packets
(as defined in RFC 1583).
Retransmission interval (as described in RFC 1583).
Number of seconds that the TAOS unit waits for a router update before removing the router’s entry from its table.
Interface transmission delay.
Poll interval of nonbroadcast multiaccess networks.
Maximum size of a packet that the TAOS unit can send to the interface.
Type of Service normal (0) cost.
Number of neighbors.
Number of adjacencies.
Number of fully-formed adjacencies.
Number of multicast floods on the interface.
Number of multicast acknowledgments on the interface.
Displaying OSPF neighbors
To display information about OSPF neighbors to the TAOS unit, include the nbrs option with the OSPF command. For example: admin> ospf nbrs
Neighbor ID Neighbor addr State LSrxl DBsum LSreq Prio Ifc
10.105.0.4 10.105.0.4 2Way/- 0 0 0 5 ie1-7-1
10.105.0.2 10.105.0.2 2Way/- 0 0 0 5 ie1-7-1
12.151.0.2 10.105.0.6 2Way/- 0 0 0 1 ie1-7-1
10.105.0.3 10.105.0.3 2Way/- 0 0 0 5 ie1-7-1
10.105.0.61 10.105.0.61 2Way/- 0 0 0 5 ie1-7-1
210.210.210.1 10.105.0.49 Exstar/BDR 0 0 0 5 ie1-7-1
192.1.1.1 10.105.0.7 2Way/- 0 0 0 5 ie1-7-1
10.123.0.8 10.105.0.8 Full/DR 0 0 0 5 ie1-7-1
10.105.0.200 10.105.0.200 2Way/- 0 0 0 5 ie1-7-1
10.103.0.204 100.103.100.204 Full/DR 0 0 0 5 ie1-7-4
3-30 APX 8000/MAX TNT/DSLTNT Administration Guide
Network Administration
Diagnostic tools for IPX routers
10.123.0.254 100.103.100.123 Full/BDR 0 0 0 5 ie1-7-4
10.102.0.2 10.102.0.2 Init/- 0 0 0 5 m1
10.101.0.2 10.101.0.2 Full/- 0 0 0 5 m1
The fields in the output contain the following information:
Field Specifies
Neighbor ID
Address assigned to the interface. In the TAOS unit, the IP address is always the address assigned to the Ethernet interface.
Neighbor addr
IP address of the router used to reach a neighbor (often the same address as the neighbor itself).
State
LSrxl
DBsum
State of the link-state database exchange. Full indicates that the databases are fully aligned between the TAOS unit and its neighbor.
For a description of possible states, see RFC 1583.
Number of LSAs in the retransmission list.
Number of LSAs in the database summary list.
LSreq
Prio
Ifc
Number of LSAs in the request list.
Designated router election priority assigned to the TAOS unit.
Interface name for the Ethernet or Connection profile name for the
WAN.
To display information about a particular OSPF neighbor, append the
Neighbor ID to the nbrs
option. For example: admin>
ospf nbrs 10.105.0.4
OSPF Router ID: 10.105.0.4
Neighbor IP address: 10.105.0.4
Neighbor State: (0x8) 2Way
Physical interface: ie1-7-1 (ie1-7-1)
DR choice: 10.105.0.8
Backup choice: 10.105.0.49
DR Priority: 5
DB summ qlen: 0 LS rxmt qlen: 0 LS req qlen: 0
Last hello: 6
# LS rxmits: 0 # Direct acks: 0 # Dup LS rcvd: 0
# Old LS rcvd: 0 # Dup acks rcv: 0 # Nbr losses: 0
# Adj. resets: 0
Diagnostic tools for IPX routers
The TAOS unit provides two diagnostic commands for monitoring IPX networks, Show
Netware Servers and Show Netware Networks.
APX 8000/MAX TNT/DSLTNT Administration Guide 3-31
Network Administration
Diagnostic tools for displaying filter information
To display the IPX service table, first enter the Terminal-Server command to access the TAOS unit’s terminal server interface, then enter the Show command with the netware servers option. For example: admin>
terminal-server
** Ascend APX Terminal Server ** ascend%
show netware servers
IPX address type server name ee000001:000000000001:0040 0451 server-1
The output contains these fields:
• IPX address : The IPX address of the server. The address uses this format:
network number:node number:socket number
• type : The type of service available (in hexadecimal format). For example, 0451 designates a file server.
• server name
: The first 35 characters of the server name.
To display the IPX routing table, enter the Show command with the netware networks option. For example: ascend%
show netware networks
network next router hops ticks origin
CFFF0001 00000000000 0 1 Ethernet S
The output contains these fields:
Fields Descriptions
network
The IPX network number.
next router
The address of the next router, or 0 (zero) for a direct or WAN connection.
hops ticks origin
The hop count from the shelf controller to the network.
The tick count to the network.
The name of the profile used to reach the network. If the origin is a network connected to a TAOS unit’s Ethernet interface, the Origin field displays
Ethernet
.
Note:
An
S
or an
H
flag can appear next to the origin.
S
indicates a static route.
H
indicates a hidden static route. Hidden static routes occur when the router learns of a better route.
Diagnostic tools for displaying filter information
The Filterdisp command enables you to display information about filters in use for active sessions. The command uses the following syntax: filterdisp usage: filterdisp <sessNum>
without <sessNum> : display all active sessions and
their filter names
with <sessNum> : display filter details of the session
3-32 APX 8000/MAX TNT/DSLTNT Administration Guide
Network Administration
Diagnostic tools for displaying filter information
Displaying filter information for all active sessions
With no arguments, the command output lists all active sessions with associated filter information. For example: admin> filterdisp
ID Username Src Route-Filter Data-Filter Call-Filter TOS-Filter
--------------------------------------------------------------------
010 dialin-23 ext
016 dialin-4 ext
017 edleung ext < filters present >
018 jwebster ext < filters present >
019 pyan loc datfilt2 callfilt4 tostestfilt
020 guest ext
021 pvc2 loc route-pvc gen_callfilt
022 pvc4 loc gen_callfilt
023 pvc5 loc
<end user list> 9 active user(s)
The output displays a session ID number, username, and an indication of where the session was authenticated (local or external). Sessions authenticated by local profiles display the filter names specified in the Connection profile. Externally authenticated sessions, such as RADIUS sessions, have no associated filter names so they appear with a
<filters present> notation. The columns in the command output provide the following information:
Output field
ID
Username
Src
Route-Filter
Data-Filter
Call-Filter
TOS-Filter
Specifies
Identification number for the session.
Name of the authenticated profile.
Source of the profile: whether it is downloaded through RADIUS
(ext) or is a local profile (loc).
If a route filter has been applied to the session. For sessions authenticated locally, the name of the filter is supplied. For externally authenticated sessions,
<filters present> indicates that a route filter has been applied. If blank, no route filter applies.
If a data filter has been applied to the session. For sessions authenticated locally, the name of the filter is supplied. For externally authenticated sessions, <filters present> indicates that a data filter has been applied. If blank, no data filter applies.
If a call filter has been applied to the session. For sessions authenticated locally, the name of the filter is supplied. For externally authenticated sessions, <filters present> indicates that a call filter has been applied. If blank, no call filter applies.
If a type of service (TOS) filter has been applied to the session. For sessions authenticated locally, the name of the filter is supplied.
For externally authenticated sessions,
<filters present> indicates that a TOS filter has been applied. If blank, no TOS filter applies.
APX 8000/MAX TNT/DSLTNT Administration Guide 3-33
Network Administration
Diagnostic tools for displaying filter information
Displaying filter details for a single active session
To display the filter details for a particular session, specify the session ID as an argument on the Filterdisp command line. (To obtain the session ID number, first use the Filterdisp command without an argument, as described in the preceding section.) If you specify an invalid session number, the command returns an error. For example: admin> filterdisp 3
Error: Invalid user session ID
The following sample output shows that no filters are applied to the sessions: admin> filterdisp 23
Hostname: pvc5
No associated filters admin> filterdisp 10
Hostname: dialin-4
No associated external filters
In the following sample output, call filters have been applied to a session that was authenticated locally: admin> filterdisp 22
Hostname: pvc4
Call Filter
Direction: In
Forward = no
Type = Generic Filter offset = 0 len = 0 more = no comp-neq = no dummyForPadding = 0 mask = 00:00:00:00:00:00:00:00:00:00:00:00 value = 00:00:00:00:00:00:00:00:00:00:00:00
Call Filter
Direction: Out
Forward = yes
Type = Generic Filter offset = 0 len = 0 more = no comp-neq = no dummyForPadding = 0 mask = 00:00:00:00:00:00:00:00:00:00:00:00 value = 00:00:00:00:00:00:00:00:00:00:00:00
The following sample output shows filters applied to an externally authenticated session: admin> filterdisp 17
Hostname: edleung searching for external filters...
Externally obtained filters exist
Data Filter
Direction: Out
3-34 APX 8000/MAX TNT/DSLTNT Administration Guide
Network Administration
Displaying software version log messages
Forward = yes
Type = IP Filter protocol = 0 source-address-mask = 0.0.0.0
source-address = 0.0.0.0
destination-address-mask = 0.0.0.0
destination-address = 0.0.0.0
Src-Port-Cmp = none source-port = 0
Dst-Port-Cmp = none dest-port = 0 tcp-estab = no
Forward = yes
Type = Generic Filter offset = 12 len = 2 more = no comp-neq = no dummyForPadding = 0 mask = ff:ff:00:00:00:00:00:00:00:00:00:00 value = 08:06:00:00:00:00:00:00:00:00:00:00
Displaying software version log messages
To facilitate troubleshooting procedures, you can configure the TAOS unit to log the current software version every hour, rather than at system startup only. Following is a sample log message:
LOG debug, Shelf 1, Controller, Time: 13:00:46--
Software version 8.0.0
Following is the relevant parameter, shown with its default value:
[in LOG] log-software-version = no
Parameter
Log-Software-Version
Specifies
Enable/disable hourly log messages reporting the current software version. The message is sent to the Syslog host. If Debug permission is enabled, the message is also displayed on the screen.
Displaying Ethernet packet contents
The Ether-Display command displays the hexadecimal contents of Ethernet packets being received and transmitted on the specified Ethernet port. You must specify how many octets of each packet you want to display.
The Ether-Display command requires that you enable debug output as follows: admin> debug on
Diagnostic output enabled
The following example displays 12 octets of each packet on a ports:
APX 8000/MAX TNT/DSLTNT Administration Guide 3-35
Network Administration
Displaying Ethernet packet contents
admin>
ether-display 0 12
ETHER XMIT: 12 of 60 octets
107E1350: 00 c0 80 89 03 d7 00 c0 7b 6b 9f d6 ........
{k..
ETHER XMIT: 12 of 64 octets
107E1350: 00 c0 80 89 03 d7 00 c0 7b 6b 9f d6 ........
{k..
ETHER RECV: 12 of 60 octets
107B8FD4: 00 c0 7b 6b 9f d6 00 c0 80 89 03 d7 ..{k....
....
ETHER XMIT: 12 of 407 octets
107E1350: 00 c0 80 89 03 d7 00 c0 7b 6b 9f d6 ........
{k..
ETHER XMIT: 12 of 161 octets
107E1350: 00 c0 80 89 03 d7 00 c0 7b 6b 9f d6 ........
{k..
ETHER RECV: 12 of 60 octets
..
..
..
To stop displaying the Ethernet statistics, specify 0 (zero) octets: admin> ether-display 0 0
Alternatively, you can stop the display by disabling debug output: admin> debug off
Diagnostic output disabled
For complete information about the Ether-Display command, see the APX 8000/MAX
TNT/DSLTNT Reference.
3-36 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
4
!
Note:
Every attempt has been made to confirm that this chapter correctly describes the functionality and output of the TAOS unit’s debug commands. However, while debug mode can be a very valuable troubleshooting tool for anyone, its primary focus is on the requirements of Lucent’s development engineers. For this reason, Lucent does not guarantee the completeness of the list of commands published for a given release nor the exhaustive cataloging of their functionality.
Caution:
Under most circumstances, debug commands are not required for correct operation of the TAOS unit. And in some circumstances they might produce undesirable results. Please use the following information with caution. Contact Lucent Technical Support with any questions or concerns.
Enabling debug permissions
Before you can access the debug commands, you must log into the TAOS unit with a User profile that specifies debug privileges.
To enable debugging privileges:
1
Open a user profile: admin> open user admin
2
Enable debug permissions: admin> set allow-debug=yes
This is a hidden parameter. It does not appear in the interface.
3
Write the profile to save the changes: admin> write
APX 8000/MAX TNT/DSLTNT Administration Guide 4-1
Using Debug Commands
Enabling debug output
Note that when you are logged into the TAOS unit with debug privileges, the interface might display normally unavailable parameters and commands, some of which are not configurable in certain situations. For this reason, you should create a special profile for debugging purposes, and only use that profile when you are debugging the TAOS unit.
Enabling debug output
To enable debug output for all commands on the system or on a card, use the Debug command as in the following examples.
To enable debug: hdlc-2/1> debug on
Diagnostic output enabled
To disable debug: hdlc-2/1> debug off
Diagnostic output disabled
When you enable debug output, the TAOS unit displays the debug messages on the terminal screen.
Debug levels
Debug levels vary depending on the command. But generally, the lower you set the debug level, the fewer messages the TAOS unit displays. Setting the debug level to 0 (zero) disables the debug output for the command.
Set the debug level with the
-t
option, as in the following examples: admin> ifmgr -t 0 ifmgr debug level is now 0 (disabled) admin> ifmgr -t 4 ifmgr debug level is now 4 (enabled)
Getting online help for debug commands
To see a list of all commands, including the debug commands, enter ?
at the command prompt, as in the following example: admin> ?
? ( user )
@fatalTest ( debug )
acctevnt ( debug )
addrpool ( debug )
ARA ( debug )
aracbmgr ( debug )
arptable ( system )
atmpdebug ( debug )
4-2 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
Using combinations of commands
auth ( user )
briChannels ( system )
brouterDebug ( debug )
brouterLoad ( debug )
brouterMessage ( debug )
brouterSave ( debug )
brouterstats ( debug )
cadslLines ( system )
callback ( debug )
callblocks ( debug )
callroute ( diagnostic )
cbacctevnt ( debug )
cbcardif ( debug )
cbcifping ( debug )
[More? <ret>=next entry, <sp>=next page, <^C>=abort]
To get basic help for a debug command, enter the Help command, followed by the name of the debug command, as in the following example: admin> help ifmgr ifmgr usage: ifmgr -option
-d (d)isplay interface table entries.
-d <ifNum> (d)etails of given i/f table entry.
-t (t)oggle debug display.
ifmgr [up|down] [ifNum|ifName]
Using combinations of commands
Since most debug commands are designed to give a developer information about specific portions of TAOS unit’s functionality, you might find it helpful to use commands in combination to troubleshoot different problems.
For example, if you see problems with the initial connection of remote users, you might want to use a combination of
Networki
,
Routmgr
and
Wantoggle
to obtain a complete view of three functions involved in establishing a call.
When troubleshooting modem-related issues, you might want to use Modemdrvstate ,
Modemdiag and Mdialout (if modem outdial is supported on your TAOS unit) to get all modem-related information for your calls.
Using several commands simultaneously not only gives you a clearer picture of a given situation, it also shows you a chronological timeline of the events that are happening.
APX 8000/MAX TNT/DSLTNT Administration Guide 4-3
Using Debug Commands
Using the debug commands
Using the debug commands
Debug commands allow you to monitor and diagnose different areas of the TAOS unit’s functionality. This section lists some of the more common debug commands and the areas of the TAOS unit’s they apply to.
Frame Relay
The following commands display information about Frame Relay interfaces.
Calls
The following commands display information about how the TAOS unit handles calls.
• Callback
• Tntcall
Authentication
The following commands display information about how the TAOS unit authenticates calls.
• Raddbgdump
• Radif
• Radstats
Host-side devices
The following commands display information about the TAOS unit’s host devices.
4-4 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
Using the debug commands
Network-side devices
The following commands display information about the TAOS unit’s network devices.
• Networki
• Pridisplay
• WANdisplay
• Wantoggle
Protocols
The following commands display information about the TAOS unit’s protocols.
• Addrpool
• Ctcheck
• Lcstate
• Leakpool
• Ospfavltree
• Ospfdebug
• Tcpflushtimer
Tunneling
• ModemDrvState
• Modemd1stats, Modemd2stats, Modemd3stats
• Ether-Stats
• Ifmgr
The following commands display TAOS unit tunneling information.
• Tunneldebug
APX 8000/MAX TNT/DSLTNT Administration Guide 4-5
Using Debug Commands
Using the debug commands
System and devices
The following commands display information about the TAOS unit’s system and devices.
• Stackusage
• Tsshow
• Watchdogtoggle
Terminal server
The following commands display information about the TAOS unit’s terminal server.
• Telnetdebug
• Tsbadterminfo
Special administrative commands
The following command should only be used when requested by Lucent technical support.
• Coredump
4-6 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
Alphabetical list of debug commands
Alphabetical list of debug commands
This section describes the TAOS unit’s debug commands in alphabetic order. The information is organized for quick reference, and does not include tutorials.
Acct-Failsafe
Description: The Acct-Failsafe debug command is available on the master shelf or the slot host cards for verifying correct accounting proxying. Slave shelf controllers and slot line cards do not support this command. (Slot host cards do not include the -d option.) admin> acct-failsafe usage: acct-failsafe -option [ params ]
-d <shelf> <slot>
(d)isplay AFS info for <shelf> <slot>
-d (d)isplay AFS info for all relevant slots
-t (t)oggle module debug level
-? display this summary
To display information about the calls on any slot which are candidates for proxy accounting.: admin> acct-failsafe -d
Slot 1/8:
HashTable @ 10542160, bucketCount: 192, callCount: 23, hashName
<afs-1:8>
Slot 2/5:
HashTable @ 10585730, bucketCount: 48, callCount: 7, hashName
<afs-2:5>
To display the same information for a single slot card in shelf 1, slot 8: admin> acct-failsafe -d 1 8
Slot 1/8:
HashTable @ 10542160, bucketCount: 192, callCount: 23, hashName
<afs-1:8>
To specify which level of debug to use for the command, use the –t option. A debug level of zero indicates none (no messages). A level of 7 is fairly verbose.
Addrpool
Description: Displays messages related to dynamic address pooling. The command is a toggle that alternately enables and disables the debug display.
Usage: Enter
addrpool
at the command prompt.
Example: Following are several examples of output produced when Addrpool is active.
With 18 addresses currently allocated from a pool:
ADDRPOOL: lanAllocate index 0 inuse 18
The address 208.147.145.155 was just allocated:
ADDRPOOL: allocate local pool address [208.147.145.155]
APX 8000/MAX TNT/DSLTNT Administration Guide 4-7
Using Debug Commands
ATMPdebug
The address 208.147.145.141 is to be freed because the user of that address has hung up. The
TAOS unit must find the pool to which the address belonged, then free the address so it is available for another user:
ADDRPOOL: found entry by base [208.147.145.141] entry
[208.147.145.129]
ADDRPOOL: free local pool address [208.147.145.141]
In the IP Global profile, the Pool-Base-Address [1] is set to 192.168.8.8, and Assign-Count [1] is set to 4:
ADDRPOOL: Deleting addrPool
ADDRPOOL: New Addr pool rc = 0 addrPool index 1 ip [192.168.8.8] count 4
The Assign-Address parameter of an existing pool is changed from 4 to 3:
ADDRPOOL: Deleting addrPool
ADDRPOOL: New Addr pool rc = 0 addrPool index 1 ip [192.168.8.8] count 3
A second pool is created. In the IP Global profile, the Pool-Base-Address [2] is set to
192.168.8.8, and Assign-Count [2] is set to 10:
ADDRPOOL: Deleting addrPool
ADDRPOOL: New Addr pool rc = 0 addrPool index 1 ip [192.168.8.8] count 4
ADDRPOOL: New Addr pool rc = 0 addrPool index 1 ip [192.168.8.8] count 4 addrPool index 2 ip [192.168.10.1] count 10
The second pool is deleted:
ADDRPOOL: Deleting addrPool
ADDRPOOL: New Addr pool rc = 0 addrPool index 1 ip [192.168.8.8] count 4
ATMPdebug
Description: Displays messages related to Lucent’s Ascend Tunnel Management Protocol
(ATMP) sessions. (ATMP is described in RFC 2107.) The command is a toggle that alternately enables and disables the debug display. You would normally use this command with the
Tunneldebug command.
Usage: Enter
atmpdebug
at the command prompt.
Example:
The mobile node sends a request to foreign agent asking for connection to the home agent:
ATMP: sendRegReq: HA=200.67.1.254:5150 RcvUdp=5150
ATMP: Id=162, FA=130.67.40.254
ATMP:MC=141.111.40.82, HomeNetName=[]
The home agent sets up a tunnel:
ATMP: received cmd <RegisterRequest> from 130.67.40.254:5150
ATMP: procRegReq: from=130.67.40.254:5150
4-8 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
AuthenDebug
ATMP: FA=130.67.40.254, MC=141.111.40.82, HomeNet=
ATMP: sendChallReq: to 130.67.40.254:5150, Id=162, EC=Good completion
ATMP: received cmd <ChallengeReply> from 130.67.40.254:5150
ATMP: procChallReply: from 130.67.40.254:5150, Id=162
ATMP: sendRegisterReply: to udp=5150, Id=162, Tunnel=156, EC=Good completion
AuthenDebug
Description: Displays messages related to Link Control Protocol (LCP) authentication on the
TAOS unit. The command is a toggle that alternately enables and disables the debug display.
This command is available on host cards such as the HDLC card and the modem card,
Usage:
authendebug
Example: The following display indicates a successful PAP authentication.
AUTH: lcp_pap_req(remote=0)
AUTH-3: verify_pap(given<len.id=13:140.57.40.135, pwdLen=6>)
AUTH-3: verify_pap No authData - getting one
AUTH-3: verify_pap: authDispatcher() == OK
AUTH-3: verify_pap_callback: AUTHCOMMAND_SUCCESS
BrouterDebug
Description: Displays messages related to the router functionality of the TAOS unit. The command is a toggle that alternately enables and disables the debug display.
You can use this command for a general view of the load experienced by the TAOS unit.
Usage: Enter
brouterdebug
at the command prompt.
Example: Typically, brouterdebug
displays very few messages. The following session took place over a period of several minutes on a TAOS unit with 40–45 users active.
admin>
brouterdebug
BROUTER debug display is ON
BROUTER_LOAD_MSG: time= 0
BROUTER_LOAD_MSG: time= 1
BROUTER_LOAD_MSG: time= 0 admin> brouterdebug
BROUTER debug display is OFF
The BROUTER_LOAD_MSG message is an indication of how busy the TAOS unit’s router function is. A low number, as is illustrated here, indicates the router is not experiencing any problems.
BrouterLoad
Description: Reports router backlog time, which indicates whether the TAOS unit is experiencing any delay. The time is shown in ticks. Multiply the number of ticks by ten to get the time in milliseconds.
You can use this command for a general view of the load experienced by the TAOS unit.
APX 8000/MAX TNT/DSLTNT Administration Guide 4-9
Using Debug Commands
Ctdebug
Usage: Enter
brouterload
at the command prompt.
Example: The following display indicates no delays in the router.
admin> brouterload
BROUTER load time is 0 ticks (x10msec)
Ctdebug
Description: Displays messages related to CIDR routing. The command is a toggle that alternately enables and disables the debug display.
Usage: Enter
ctdebug
at the command prompt.
Example:
admin>
ctdebug
CIDR tree debug is 0
Cubit
Description: Displays the statistics of the shelf controller’s 3 cubit chips. The command used to gather statistics from the chips. The cubit chips direct packet-bus traffic between each other, between each other and the shelf-controller SAR and slot card SAR, and intershelf to other cubits.
Usage:
cubit -s|-r|-w|-d|-i
|
-z [ parameters ]
Syntax element
-s
-r cubit vpi
-d cubit startVPI
-i
-z
Description
Show the statistics of all 3 cubits.
Read the content of the cubit at the specified
VPI.
Dump the content of the cubit.
Re-initialize the cubits.
Reset the cubits.
Example:
In the following example, cubit B is not operating normally and the shelf controller might be defective. Note that receive errors are logged as resets: admin>
cubit -s
Cells CUBIT_A CUBIT_B CUBIT_I
----- ------- ------- -------
received: 1316806 0 2740761 discarded: 0 0 0 misrouted: 0 0 0
HEC Error: 0 0 0
Resets: 0 5151 0
4-10 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
DTunnel
The following example indicates that the multishelf is operating normally: admin>
cubit -s
Cells CUBIT_A CUBIT_B CUBIT_I
----- ------- ------- -------
received: 557088 3990584 3497345 discarded: 0 0 0 misrouted: 0 0 0
HEC Error: 0 0 0
Resets: 0 0 0
DTunnel
Description: Displays the status of enabled tunnels on the TAOS unit.
Usage: Enter
dtunnel
at the command prompt.
Example:
admin> dtunnel
MajDev Proto Agent Mode HA Type IPX sap UDP password
------ ----- ---------- ------- ------- ----- --------
7 ATMP Home-Agent Router disabled 5150 lucent
Idle-Limit 120 mins
Tunnels:
--------------------------------------------------
Tunnel 36734 IfNum 65535 Majdev 7 Agent Address 130.67.40.254:5150
Ident=0x56 TN=0x47BF DnsSN=0
ATMP Home-Agent
State 5 (UP) Router Mode Home Network Name
Remote client Idle-Limit 120 mins
Client IP Address 141.111.40.86/32
--------------------------------------------------
Tunnel 36732 IfNum 65535 Majdev 7 Agent Address 130.67.40.254:5150
Ident=0x55 TN=0x47BE DnsSN=0
ATMP Home-Agent
State 5 (UP) Router Mode Home Network Name
Remote client Idle-Limit 120 mins
Client IP Address 141.111.40.85/32
Ether-Stats
Description: Displays all statistics and error counters maintained by the 10Base-T Ethernet driver.
Usage:
ether-stats 0 n
Where
0
is the first Ethernet port for which to display statistics and n
is the last.
Example:
APX 8000/MAX TNT/DSLTNT Administration Guide 4-11
Using Debug Commands
FRDLstate
admin>
ether-stats 0
Tx unicast: 48382
non-unicast: 23736
octets: 10746332
collisions: 443
dma under: 0
cts loss: 0
no carrier: 0
late coll: 0
Rx unicast: 45952
non-unicast: 31307
octets: 13491043
collisions: 0
short frame: 0
dma over: 0
no resource: 0
Alignment: 0
Unaligns: 0
Length Errs: 0
Restarts: 0 admin> ether-stats 0-10
Tx unicast: 48559
non-unicast: 23784
octets: 10805138
collisions: 443
dma under: 0
cts loss: 0
no carrier: 0
late coll: 0
Rx unicast: 46165
non-unicast: 31500
octets: 13576590
collisions: 0
short frame: 0
dma over: 0
no resource: 0
Alignment: 0
Unaligns: 0
Length Errs: 0
Restarts: 0
FRDLstate
4-12
Description: Displays information regarding the state of the Frame Relay connections, focusing mostly on Data Link information. The command is a toggle that alternately enables and disables the debug display.
Usage: Enter
frdlstate
at the command prompt.
Example:
APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
FRdump
admin> frdlstate
FRDLCALL state display is now ON
In this example, an outgoing call is to be placed. A route to the destination is available over a
Frame Relay link. The following message appears:
FRDLCALL: Clear Call for route: 136
The following message indicates that an outgoing call is connected:
FRDLCALL-136: call complete, status 1, 0 channels
The next message indicates that either the TAOS unit or the far end device has destroyed a route. The TAOS unit updates its table to reflect this routing change.
FRDLCALL-136: dead call
FRDLCALL-136: route destroyed
FRdump
Description: Displays a snapshot of the Frame Relay Interface table. The display shows data for each DLCI assigned to a Frame Relay link.
Usage: Enter
frdump
at the command prompt.
Example:
admin>
frdump
* Frname State DLinkAddr routeID.id frmgrLink dlIfNum dlIfSpeed
frt14 CONNECTED 1012c920 15 0 738 512000
*dlci Addr ifNum routeID dataLink state
304 100cada0 23 136 1012c920 INACTIVE
frt18 CONNECTED 1012ffa0 14 0 742 1536000
*dlci Addr ifNum routeID dataLink state
306 101719a0 33 36 1012ffa0 ACTIVE
604 10193c60 27 32 1012ffa0 ACTIVE
603 10191fe0 26 31 1012ffa0 ACTIVE
frt17 CONNECTED 10149b60 13 0 741 1536000
*dlci Addr ifNum routeID dataLink state
305 101975e0 32 35 10149b60 ACTIVE
600 101910a0 24 30 10149b60 ACTIVE
303 1018cea0 22 28 10149b60 ACTIVE
301 10186360 20 26 10149b60 ACTIVE frt16 CONNECTED 1017ad20 7 0 740 1536000
*dlci Addr ifNum routeID dataLink state
605 101961e0 29 34 1017ad20 ACTIVE
300 1018a820 21 27 1017ad20 ACTIVE frswan4 CONNECTED 10125ba0 2 0 734 64000
*dlci Addr ifNum routeID dataLink state
411 101592a0 31 5 10125ba0 ACTIVE
407 10155ae0 30 4 10125ba0 ACTIVE
403 10153be0 25 3 10125ba0 ACTIVE
APX 8000/MAX TNT/DSLTNT Administration Guide 4-13
Using Debug Commands
FRinARP
FRinARP
Description: Performs an Inverse ARP test over the specified Frame Relay link and DLCI.
You can use FRinARP to help troubleshoot connectivity and routing problems over a Frame
Relay link.
Usage: frinarp Frame_Relay_profile_name DLCI
Example:
admin>
frinarp FR-1 38
frInArp: frinarp frname dlci
Inverse Arp op 2304 hw type 3840 prot type 8 hw len 2 prot len 4
Source Hw address 0401 Target Hw address 0000
Source Protocol address cd933401 Target Protocol address cd930005
FRLinkState
Description: Displays Frame Relay control messages. The command is a toggle that alternately enables and disables the debug display.
Usage: Enter
frlinkstate
at the command prompt.
Example:
admin>
frlinkstate
FR control msg display is ON
The following message indicates that the TAOS unit sent a Frame Relay Status Enquiry. The
Send sequence number is 135. The Receive sequence number is 134.
FRMAIN: time 67192300, send status enquiry (135,134)
The next message indicates that DLCI 16 is being processed. This is a normal message. You should see one process
message for each DLCI.
process pvc dlci 16
FRLMI
Description: Displays Frame Relay Local Management Interface (LMI) information. The command is a toggle that alternately enables and disables the debug display.
Usage: Enter frlmi
at the command prompt.
Example:
admin>
frlmi
FRMAIN: Lmi display is ON
FRMAIN: Setting timer DTE
The following message validates the consistency of sequence numbers in LMI messages. The
144 after want
indicates the original sequence number the TAOS unit sent. The two numbers after the second got
indicate the switch’s Send sequence number and the Switch’s report of the last sequence number it received from the TAOS unit, respectively. The original sequence number should match the switch’s report of the last sequence number it received.
FRMAIN: Time 67201400, got link report: want (*,144), got (144,144)
4-14 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
FRMgrDump
FRMgrDump
Description: Displays the Frame Relay link and DLCI information, including states and counters.
Usage: Enter
frmgrdump
at the command prompt.
Example:
admin>
frmgrdump
Data Link Info
Status
B04FBD40 ACTIVE B04C0480 1532 19759603 19530429
Status enq sent = 66710 rsp rcvd = 66763 upd rcvd = 53 timeouts = 1
Errors
UI field = 0 PD field = 0
CR field = 0 msg type = 0 stat rsp = 0 lock shf = 0 inv info = 0 rpt type = 0
Last Error type = 5 time = 6100
Fr Type 0 value: 20 octets @ B04FBE26
[0000]: 04 91 03 CC 45 00 00 3A 4B 0E 00 00 7F 11 54 D7
[0010]: CD 93 08 07
LMI type = AnnexD
DTE Monitor n391 = 6, t391 = 10, n392 = 3, n393 = 4
Event: recv seq 155 send Seq 155 Index = 0, cycles left = 4
OK OK OK OK OK OK OK OK OK OK
DCE Monitor t392 = 15,n392 = 3, n393 = 4
Event: dce send seq 0 index = 0
OK OK OK OK OK OK OK OK OK OK
DLCI info
--addr-- dlci --state- userHndl n201 --check- -pkt xmit- -pkt recv-
B04C09A0 0 ACTIVE 0 1532 NO CHECK 66710 66763
---DE--- --FECN-- --BECN-- -crTime- chgTime pending
0 0 0 100 100 FALSE
FRPriorityErrors
Description: Reports statistics about Frame Relay priority errors on a host card. All values in its output should be zero. A non-zero value indicates an extreme shortage of memory.
For example: hdlc-1/5>
frPriorityErrs
Output:
_sendStatusEnquiryNoMbuf: 0
_mkStatusReplyNoBuf: 0
_mkStatusReplyMbuf: 0
FRScert
Description: Toggles between Sprint and Frame Relay Forum LMI checks. The default is the
Sprint certification policy. In most cases, the default setting is correct and should not be changed.
APX 8000/MAX TNT/DSLTNT Administration Guide 4-15
Using Debug Commands
FRstate
Usage: Enter
frscert
at the command prompt.
Example:
admin>
frscert
frSCert is FRFCert admin>
frscert
frSCert is SCert
FRstate
Description: Displays messages related to Frame Relay state changes. The command is a toggle that alternately enables and disables the debug display.
Usage: Enter
frstate
at the command prompt.
Example: An administrator enables the display, data is received from the Frame Relay interface and processed, and the administrator disables the display.
admin>
frstate
FRrly state display is ON
FRRLYIF: Calling frifRecv routeId 20
FR1490 dataFrom wan entry state 2
FRRLYIF: Send up stack ifnum 1
FRRLYIF: Calling frifRecv routeId 20
FR1490 dataFrom wan entry state 2
FRRLYIF: Send up stack ifnum 7
FRRLYIF: frIfSend ifNum 1
FR1490 data to wan entry state 2
FRRLYIF: datatoWan datalink B04C0480 admin>
frstate
FRrly state display is OFF
GRE
Description: Displays the TAOS unit’s Generic Routing Encapsulation (GRE) information.
The command has little practical use other than as a tool for developmental engineering.
IFMgr
Description: Displays interface-table entries for the Ethernet interface, toggles the debug display, and marks an interface as enabled or disabled. This command is available on the shelf controller and on host cards such as the Ethernet, modem, and HDLC cards. The output differs slightly depending on where the command is executed.
Usage:
ifmgr [
-d
[
ifnam/ifnum
] |
-t
] [
up
|
down ifnum
|
ifname
]
Syntax element
-d
-d ifname/ifnum
Description
Display interface table entries.
Display details of the specified interface name or number.
4-16 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
IFMgr
Syntax element Description
-t
Toggle debug display.
up | down ifnum | ifname
Enable or disable the specified interface. These options have the same effect as setting the Enabled parameter in the Ethernet profile, and are subject to the same limitations.
Example: To view the IFMgr usage summary for an Ethernet card in slot 4, first open a session to the card: admin> open 1 4
Then you can use the
-d
option to view the interface number and name: ether-1/4> ifmgr -d if slot:if u p ifname mac addr local-addr
---------------------------------------------------
000 0:00:000 * pb0 000000000000 0.0.0.0/32
001 1:17:011 * ie1-4-1 00c07b6d23f0 11.1.1.1/32
002 1:17:013 * ie1-4-2 00c07b6d23f1 11.1.2.1/32
003 1:17:015 * ie1-4-3 00c07b6d23f2 11.1.3.1/32
004 1:17:017 * ie1-4-4 00c07b6d23f3 11.1.4.1/32
005 1:17:019 * ie1-4-5 00c07b6d23f4 11.1.5.1/32
<end>
The IFMgr -d output for an Ethernet card contains the following fields:
Field
if slot:if u p ifname mac addr local-addr
Description
Ethernet interface number.
Shelf, slot and system-wide interface number. (This interface number is reported by executing the IFMgr command on the shelf controller.)
Flag indicating whether the interface is up (*) or down (-).
Flag indicating whether the interface is permanent. A
P indicates a permanent interface. A hyphen (-) or a blank indicates that it is not.
A permanent interface is an interface configured in the command-line interface and stored in the TAOS unit’s
NVRAM. All the Ethernet interfaces and the virtual interfaces made for Connection profiles are permanent.
Transient interfaces are those the TAOS unit builds from
RADIUS, TACACS, or an Answer profile. These interfaces have no interface entry when the connection is down.
Interface name.
Interface MAC address.
Interface local address.
APX 8000/MAX TNT/DSLTNT Administration Guide 4-17
Using Debug Commands
IFMgr
Following is an example of disabling an interface: ether-1/4>
if mgr down ie1-4-1
The IFMgr
-d
output indicates that the interface is disabled by displaying a hyphen instead of an asterisk in the Up ( u
) column: ether-1/4> ifmgr -d if slot:if u p ifname mac addr local-addr
---------------------------------------------------
000 0:00:000 * pb0 000000000000 0.0.0.0/32
001 1:17:011 - ie1-4-1 00c07b6d23f0 0.0.0.0/32
002 1:17:013 * ie1-4-2 00c07b6d23f1 11.1.2.1/32
003 1:17:015 * ie1-4-3 00c07b6d23f2 11.1.3.1/32
004 1:17:017 * ie1-4-4 00c07b6d23f3 11.1.4.1/32
005 1:17:019 * ie1-4-5 00c07b6d23f4 11.1.5.1/32
<end>
Note:
The Netstat command also displays a hyphen to indicate a disabled Ethernet interface.
To mark an interface as up, use the up
option: ether-1/4> ifmgr up ie1-4-1
An interface can be administratively disabled by using the IFMgr command or by updating the
Ethernet profile, or it can be marked as down by the Ethernet driver when Link-State-Enabled is Yes and Link-State is Down. Therefore, using the
Up
option to the IFMgr command does not necessarily enable the interface. However, it does mark the interface as up.
Following is an example of using the IFMgr command on the shelf controller: admin>
ifmgr -d
bif slot sif u m p ifname host-name remote-addr local-addr
----------------------------------------------------------------------------
000 1:17 000 * ie0 - 0.0.0.0/32 192.168.7.133/32
001 1:17 001 * lo0 - 0.0.0.0/32 127.0.0.1/32
002 0:00 000 * rj0 - 0.0.0.0/32 127.0.0.2/32
003 0:00 000 * bh0 - 0.0.0.0/32 127.0.0.3/32
004 0:00 000 * wanabe - 0.0.0.0/32 127.0.0.3/32
005 0:00 000 * local - 0.0.0.0/32 127.0.0.1/32
006 0:00 000 * mcast - 0.0.0.0/32 224.0.0.0/32
007 0:00 000 - tunnel7 - 0.0.0.0/32 192.168.7.133/32
008 1:11 001 * p wan8 apx-t1-t32 200.2.1.2/32 192.168.7.133/32
009 1:11 002 * p wan9 apx-t1-t32 200.2.2.2/32 192.168.7.133/32
010 1:11 003 * p wan10 apx-e1-t22 200.3.2.2/32 192.168.7.133/32
011 1:11 004 * p wan11 apx-e1-t32 200.5.1.2/32 192.168.7.133/32
012 1:11 005 * p wan12 apx-e1-t32 200.5.2.2/32 192.168.7.133/32
013 1:11 006 * p wan13 apx-t1-t22 200.1.1.2/32 192.168.7.133/32
014 1:15 001 * p wan14 apx-t1-s1- 100.1.100.2/32 100.6.100.2/32
015 1:11 007 * p wan15 apx-e1-t22 200.3.1.2/32 192.168.7.133/32
016 1:11 008 * p wan16 cisco-t221 200.4.103.2/32 192.168.7.133/32
017 1:11 009 * p wan17 m-e1-t2211 200.4.4.2/32 192.168.7.133/32
018 1:11 010 * p wan18 m-e1-t2212 200.4.4.3/32 192.168.7.133/32
019 1:17 000 - p wan19 m2t81 200.8.1.2/32 192.168.7.133/32
020 1:17 000 - p wan20 m41 200.4.1.2/32 200.6.1.2/32
021 1:16 001 * p wan21 p1321n<>p1 0.0.0.0/32 0.
0.0.0/32
4-18 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
IFMgr
[More? <ret>=next entry, <sp>=next page, <^C>=abort]
The IFMgr output on cards other than the Ethernet card includes the following fields:
Field
bin slot sif u m p ifname host-name remote-addr local-addr
Description
Bundle interface number. There is one interface number per bundle, including MPP connections. It is the global interface-table number.
Shelf and slot the interface is assigned to.
Slot interface.
Flag indicating whether the interface is up (*) or down (-).
Indicates that the interface is part of an MP bundle.
Flag indicating whether the interface is permanent. A
P
indicates a permanent interface. A hyphen (-) or a blank indicates that it is not.
A permanent interface is an interface that is configured in the command-line interface and stored in the TAOS unit’s NVRAM. All the Ethernet interfaces and the interfaces based on Connection profiles are permanent. Transient interfaces are those the TAOS unit builds from RADIUS, TACACS, or an Answer profile. These interfaces have no interface entry when the connection is down.
Interface name.
Host name of remote device.
Remote address of device as configured in a Connection profile.
Local address of device as configured in a Connection profile.
Following is an example of displaying information about a particular interface: admin> ifmgr -d 009 inUse: Yes hostName: apx-t1-t3212-s4 dialoutName:
ExternalAuth: No
ExternFilters: No
ExternRoutes @ 0
ExternIpxRoutes @ 0 miscInfo @ 0 reDirectDest: 0.0.0.0
DLCI routeId: 34
MP(P) id: 0
Logical iff: 2 virtual id: 0, virtual next @ 0, virtual main @ 0 minor device: 9 device status: 0x303 mtu: 1528 ip_addr: 192.168.9.133
dstip_addr: 100.2.1.2
APX 8000/MAX TNT/DSLTNT Administration Guide 4-19
Using Debug Commands
IPXRIPdebug
netmask: 255.255.255.0
net: 192.168.9.0
subnet: 192.168.9.133
bcast: 192.168.9.255
nbcast: 192.168.9.133
directed-bcast: no macaddr: 000000000000 inp_qcnt: 0 out_qcnt: 0 nexthop: 0.0.0.0
Num pkts queued for brouter: 0 proxy_arp_mode: 0 proxy_arp_head: 0
No associated connection profile
The ICMP-Reply-Directed-Bcast parameter in the IP-Global profile specifies whether the
TAOS unit responds to directed-broadcast ICMP echo requests. If set to No, the system does not respond to any directed-broadcast ICMP requests. The setting of this parameter is shown in the Directed-Bcast field in the Ifmgr output.
IPXRIPdebug
Description: Displays incoming and outgoing IPX RIP traffic. The command is a toggle that alternately enables and disables the debug display.
Usage: Enter
ipxripdebug
at the command prompt.
Example:
admin> ipxripdebug
IPX-RIP state display is ON
The following message appears as the TAOS unit sends an IPX RIP packet announcing its route:
IPXRIP: 10000a17 announced 0 routes on interface 1000:
Next, a Pipeline 50 has dialed the TAOS unit. The TAOS unit receives a RIP route from the
Pipeline.
IPXRIP: received response from ac1b0001:00c07b5e04c0 (1 nets).
The following message indicates that the TAOS unit is delaying sending a RIP packet to prevent the interpacket arrival time from being shorter than busy/slow boxes can handle. An
IPX router should never violate the minimum broadcast delay.
IPX-RIP: too soon to send on interface 1000.
IPXRIP: 10000a81 announced 0 routes on interface 1000:
IPXRIP: received response from ac1b0001:00c07b6204c0 (1 nets).
IPXRIP: 10000aa6 announced 0 routes on interface 1000:
IPXRIP: received response from ac1b0001:00c07b5504c0 (1 nets).
IPXRIP: 10000abc announced 0 routes on interface 1000:
4-20 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
Lanval
Lanval
Description: Displays messages related to external validation requests. You can use this command in conjunction with radif to troubleshoot authentication issues.
Usage: Enter
lanval
at the command prompt.
Example:
admin>
lanval
LANVAL state display is ON
LANVAL: radius auth, id B054AD60
LANVAL: radius callback, id B054AD60, auth SUCCESS
LANVAL:_lanvFreeInfo: freeing iprof@B05A9360
LifDebug
Description: Displays ISDN layer 2 and layer 3 information. The command is a toggle that alternately enables and disables the debug display.
Usage: Enter
lifdebug
at the command prompt.
Example: Following are several examples of
LifDebug
output: admin> lifdebug
LIF debug is now ON
A packet is being sent over the WAN. The packet is constructed:
LIF_SendPkt(): DSL 0, source 0x400, destination 0x300, event 0x340, SAPI 0, CES 1, Call_Id 77, Chan_Id 0
The following message displays the contents of the packet:
PACKET:
Header (4): a0 50 59 b0 Info (9): 08 02 00 00 84 08 02 80 90 01
L3_Go: source 0x400, event 0x340, DSL 0, call_id 77, ces 1
L3_ProcessUserEvent(): State 0x9, Event 0x84, Index 6,
DSL 0, CallID 77
Another packet is sent:
LIF_SendPkt(): DSL 0, source 0x300, destination 0x205, event 0x240, SAPI 0, CES 1, Call_Id 77, Chan_Id 0
PACKET:
Header (4): a0 50 59 b0 Info (9): 08 02 83 fe 45 08 02 80 90 00
L3_Go(): end of L3 task, NLCB State 10
L2_Go(): DSL_Id=0, SAPI=0, CES=1, TEI=0, Event=240
L2_ProcessEvent(): DSL 0, index 13, state 7
L2_ProcessEvent(): DSL 0, index 19, state 7
L2_Go(): DSL_Id=0, SAPI=0, CES=1, TEI=0, Event=1
L2_ProcessEvent(): DSL 0, index 1, state 7
L2_Go() end: DLCB->State 7
APX 8000/MAX TNT/DSLTNT Administration Guide 4-21
Using Debug Commands
MdbStr
MdbStr
!
Description: Modifies the default modem AT command strings used by the modems on the
TAOS unit for both incoming and outgoing calls. Previously, you could not modify the AT command for modems on the TAOS unit. You could only affect the string in minor ways by modifying the parameters in the Terminal-Server>Modem-Configuration subprofile. Note that when the modem card or the TAOS unit is reset, the AT command strings revert to their defaults.
The MdbStr command also allows you to return the string to its factory default settings.
The modem chip in the TAOS unit supports AT commands up to 56 characters in length. To fully support all possible functionality, each command is sent as two separate strings. You can modify one or both strings.
Caution:
The AT command string initializes the modems it supports. When you change the
AT command string, you are changing the functionality of the modems. Use this command with caution.
Here are the two default strings for the TAOS unit:
1
AT&F0&C1V0W1X4
2
AT%C3\N3S2=255S95=44S91=10+MS=11,1,300,33600A
Usage:
mdbstr [ 0 ] [ 1 ] [ 2 ] [ AT-command-string ]
Example: The following examples show you how to modify each portion of the AT command string:
To override the existing first string with a new string: mdbstr 1 AT&F0&C1V1W1
This will override the second portion of the AT command string: mdbstr 2 AT%C3\N3S2=255S95=44S91=10+MS=11,1,300,14400A
This will return both strings to their factory default settings: mdbstr 0
MDialout
Description: Displays messages related to modem dial out. This command can be used in conjunction with the ModemDrvState command to get detailed information about outbound modem calls.
The command is a toggle that alternately enables and disables the debug display.
Usage: Enter
mdialout
at the command prompt.
Example: In the following example, a modem on the TAOS unit prepares to make an outbound modem call, but never receives a dialtone.
admin> mdialout
MDIALOUT-2/4: >> CURR state=Await_Off_Hook, NEW
4-22 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
MDialSess
event=Event_Off_Hook
MDIALOUT-2/4: connected to DSP!
MDIALOUT-2/4: rqst tone (14) via channelIndex 0
MDIALOUT-2/4: tone generation started.
MDIALOUT-2/4: >> CURR state=Await_Dial_Tone, NEW event=Event_Dialtone_On
MDIALOUT-2/4: decode timer started.
MDIALOUT-2/4: << NEW state=Await_1st_Digit
MDIALOUT-2/4: enabling tone search, channel index=0, timeslot=0
MDIALOUT-2/4: << NEW state=Await_1st_Digit
MDIALOUT-2/4: >> CURR state=Await_1st_Digit, NEW event=Event_On_Hook
MDIALOUT-2/4: stopping decode timer.
MDIALOUT-2/4: rqst tone (15) via channelIndex 0
MDIALOUT-2/4: disabling tone search, channel index=0
MDIALOUT-2/4: disconnected from DSP.
MDIALOUT-2/4: << NEW state=Await_Off_Hook
MDIALOUT-2/4: >> CURR state=Await_Off_Hook, NEW event=Event_Close_Rqst
MDIALOUT-?/?: << NEW state= <DELETED>
MDialSess
Description: Displays all the active modem dialout sessions.
Usage: Enter mdialsess
at the command prompt.
Example:
admin>
mdialsess
entry slot:mdm route port hookDetect DSP:tone:timr:decode state
1 6:4 145 16 pollForOff n : n : n : n Await_Off_Hook
ModemD1Stats, ModemD2Stats, ModemD3Stats
Description: Displays modem statistics. ModemD1Stats displays statistics for the first 16 modems, ModemD2Stats displays statistics for the second 16 modems, and ModemD3Stats displays statistics for the last 16 modems.
Usage:
modemd1stats
To use this command, first open a session with a modem card, then enter the command.
Example:
modem-1/2>
modemd1stats
modem: ansFail ansOK 1-2400 2.4-14.4 14.4-up 21.6+up 28.8+up
1/ 0: 3 171 0 0 171 171 171
1/ 1: 3 171 0 0 171 171 171
1/ 2: 2 172 0 0 172 172 172
1/ 3: 2 172 0 0 172 172 171
1/ 4: 4 170 0 0 170 170 170
APX 8000/MAX TNT/DSLTNT Administration Guide 4-23
Using Debug Commands
ModemDrvDump
1/ 5: 1 173 0 0 173 173 172
1/ 6: 0 174 0 0 174 174 174
1/ 7: 1 173 0 0 173 173 173
1/ 8: 1 173 0 0 173 173 173
1/ 9: 0 174 0 0 174 174 174
1/10: 2 172 0 0 172 172 172
1/11: 1 173 0 0 173 173 173
1/12: 1 173 0 0 173 173 173
1/13: 0 174 0 0 174 174 174
1/14: 1 173 0 0 173 173 173
1/15: 3 171 0 0 171 171 170
ModemDrvDump
Description: Displays information about the status of each modem.
Usage: Enter
modemdrvdump
at the command prompt.
Example: Following is a message about modem 0 (the first modem) in the modem card in slot
3 on the TAOS unit. The numbers in brackets indicate number of calls with unexpected open requests, unexpected Rcode events, unexpected release events, and unexpected timeouts:
MODEMDRV-3/0: Unexp Open/Rcode/Rlsd/TimOut=[0,0,0,0]
ModemDrvState
Description: Displays communication to and from the modem driver on the TAOS unit. You can see which buffers are allocated and which AT command strings are being used to establish modem connections.
You can also determine whether data is received from the modem in an understandable format.
If line quality is poor, the modem driver attempts to parse incoming data from the modem, but it might not be successful. This command can be used in conjunction with the MDialout command to get detailed information about outbound modem calls.
The command is a toggle that alternately enables and disables the debug display.
Usage: Enter
modemdrvstate
at the command prompt.
Example: Following are examples of a modem call coming into the TAOS unit, and a modem call being cleared from the TAOS unit: admin>
modemdrvstate
MODEMDRV debug display is ON
Modem 1 on the modem card in slot 3 has been assigned to answer an incoming modem call:
MODEMDRV-3/1: modemOpen modemHandle B04E3898, hdlcHandle B026809C, orig 0
The modem is idle, so it is available to answer the call:
MODEMDRV-3/1: _processOpen/IDLE
The next two lines show the TAOS unit’s modem sending the first string:
4-24 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
ModemDrvState
MODEMDRV: Answer String, Part 1 - AT&F0E0+A8E=,,,0
A buffer needs to be allocated for sending the command out to the WAN:
MODEMDRV-3/1: _hdlcBufSentFnc: buffer = 2E12EAE0, status = SENT
Buffers are allocated for data being received from the WAN:
MODEMDRV-3/1: _hdlcBufRcvdFnc: data=2E13ADF0, len=8, parseState[n,v]=[0,0], status= RCVD
MODEMDRV-3/1: _hdlcBufRcvdFnc: data=2E13BA20, len=5, parseState[n,v]=[0,0], status= RCVD
The TAOS unit’s modem receives an OK from the calling modem:
MODEMDRV-3/1: data =OK
The process is repeated for strings 2 and 3:
MODEMDRV-3/1: processTimeout/DIAL_STR2[2D]
MODEMDRV: Answer String, Part 2 - AT&C1V1\V1W1X4S10=60
MODEMDRV-3/1: _hdlcBufSentFnc: buffer = 2E12EAE0, status = SENT
MODEMDRV-3/1: _hdlcBufRcvdFnc: data=2E13C038, len=2, parseState[n,v]=[0,0], status= RCVD
MODEMDRV-3/1: data = 0
MODEMDRV-3/1: _processTimeout/DIAL_STR3
MODEMDRV: Answer String, Part 3 -
AT%C3\N3S2=255S95=44S91=10+MS=11,1,300,33600,A
Now result codes are processed to clarify the characteristics of the connection.
MODEMDRV-1/1: _hdlcBufRcvdFnc: data=9880C628, len=48, parseState[n,v]=[1,0], stD
MODEMDRV-1/1: data =
CONNECT 115200/V34/LAPM/V42BIS/28800:TX/33600:
MODEMDRV-1/1: decodeSLC[15]=<CONNECT 115200/> checking for error correction
MODEMDRV-1/1: decodeSLC[4]=<V34/> checking for error correction
MODEMDRV-1/1: decodeSLC[5]=<LAPM/> checking for error correction[29]
MODEMDRV-1/1: decodeSLC[7]=<V42BIS/> checking for compression[21]
MODEMDRV-1/1: decodeSLC[9]=<28800:TX/> checking for xmit[1]
MODEMDRV-1/1: _hdlcBufRcvdFnc: data=9880C828, len=4, parseState[n,v]=[4,0], staD
MODEMDRV-1/1: data = RX
> checking for recv[0]C[9]=<33600:RX decodeSLC complete
At this point the modem call is up, and the modem driver has completed its tasks. The call will be passed to Ethernet resources:
MODEMDRV-3/1: _processRcodeEvent/AWAITING RLSD, mType=5, RLSD=0
MODEMDRV-3/1: _processRlsdChange/AWAITING RLSD = 1
Following is the normal sequence of steps for a modem call that is cleared (by either modem).
Modem 5 on the modem card in slot 7 of the TAOS unit is freed from the previous call, and it is reinitialized (so it is available for the next call).
APX 8000/MAX TNT/DSLTNT Administration Guide 4-25
Using Debug Commands
MPCMtoggle
MODEMDRV-7/5: modemClose modemHandle B04E6F38
MODEMDRV-7/5: _closeConnection:ONLINE, event=3
MODEMDRV-7/5: _processTimeout/INIT
MPCMtoggle
Description: Displays information about related channel addition with Multilink
Point-to-Point connections. This information is not related to MP+ or BACP connections. This command displays only information from connections established as MP (RFC1717) connections.
The command is a toggle that alternately enables and disables the debug display.
Usage: Enter
mpcmtoggle
at the command prompt.
Example:
admin>
mpcmtoggle
MPCM debug is now ON
MPCM-432: adding 1 channels
MPentry
Description: Displays information for a specified, active, MP or MP+ connection, including the options negotiated in the connection. This command can be extremely helpful when researching MP or MP+ compatibility issues.
Note:
The MpID number that must be entered is an internally generated number. To get a list of all currently assigned MpID numbers on your TAOS unit, enter the
IFmgr -d
command and specify an interface name or number.
Usage: Enter
mpentry
at the command prompt.
Example: The following example shows an MP+ call (noted as MPP). The End Point
Discriminator (used to bundle the channels together) is shown under bundle id . In this case, it is the hardware MAC address of the calling device.
admin>
mpentry
MpID required admin>
mpentry 28
MP entry 28 @ B055DE60
MpID 28, Flags: delete No, remote No, ncp Yes, mpp Yes bacp No bundle id: 15 octets @ B0558BE0
[0000]: 03 00 C0 7B 53 97 07 73 65 63 61 2D 68 73 76 vjInfo @ B0562060 startTime 227521989, mrru: local 1524, peer 1524 send: ifIx 1, count 0, seq 77268 / recv: seq 75046
IF 50, send idle 0, recv idle 1, last seq 75045 mode 0 #chans 1
Head:
Tail
Reassembe packet cnt 0 bad lrg pkts 0
4-26 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
MPPCM
MPPCM
Description: Displays MP+ call-management information. The command is a toggle that alternately enables and disables the debug display. You can use it in conjunction with the
MPtoggle command, since each command logs debug from a different place in code, but both display information based on multichannel connections.
Usage: Enter
mppcm
at the command prompt.
Example:
admin> mppcm
MPPCM debug is now ON
The following 8 messages indicate that a second channel is added to a 1-channel MP+ connection:
MPP-5: Event = Utilization, CurrentState = Idle/A
MPP-5: check dynamic says: current = 1, recommended = 2
MPP-5: requesting 1 additional channel(s)
MPP-5: 1 call(s) posssible.
MPP-5: new state is: Add/C
MPP-5: Event = RxAddComplete, CurrentState = Add/C
MPP-5: enterIdleA, AddLock = Yes, RemoveLock = No
MPP-5: new state is: Idle/A
The following 12 messages indicate that a remote management session is brought up for the
MP+ user with MpID 28. You can open a remote session to an MP+ user from the terminal server.
MPP-28: Event = StartRM, CurrentState = Idle/A
MPP-28: start remote management
MPP-28: new state is: Idle/A
MPP-28: Event = RxRmRsp, CurrentState = Idle/A
MPP-28: remote management response (0)
MPP-28: new state is: Idle/A
MPP-28: Event = RxRmTxReq, CurrentState = Idle/A
MPP-28: new state is: Idle/A
MPP-28: Event = RecvRMM, CurrentState = Idle/A
MPP-28: new state is: Idle/A
MPP-28: Event = StopRM, CurrentState = Idle/A
MPP-28: stop remote management admin>
mppcm
MPPCM debug is now OFF
MPtoggle
Description: Displays information about MP and MP+ connections. You can use this command in conjunction with the MPPCM command, since each command logs debug from a different place in code, but both display information based on multichannel connections. The command is a toggle that alternately enables and disables the debug display.
Usage: Enter
mptoggle
at the command prompt.
Example:
APX 8000/MAX TNT/DSLTNT Administration Guide 4-27
Using Debug Commands
MSstat
admin>
mptoggle
MP debug is now ON
MP-26: sending control message 191
MP-5: sending control message 76 admin>
mptoggle
MP debug is now OFF
MSstat
Description: The MSstat command displays information about communications with other shelves over the intershelf TDM bus. On the master shelf, the command displays statistics for the slave shelves. On a slave shelf, it displays statistics for the master and other slaves.
Usage: msstat
Example: From a master shelf: admin>
msstat
SH State TxQs TxSeq RxSeq Resend Timer LinkUp
2 4 0 13312 13116 3 0 2
3 4 0 12405 11822 0 0 2
4 2 0 0 0 0 1 0
5 2 0 0 0 0 1 0
6 2 0 0 0 0 1 0
7 2 0 0 0 0 1 0
8 2 0 0 0 0 1 0
9 2 0 0 0 0 1 0
Note that there are entries for all shelves (2-9), even though this system has only three shelves.
The MSstat command’s output includes the following fields:
Field
SH
State
TxQs
TxSeq
RxSeq
Resend:
Timer
LinkUp
Description
Shelf number
Indicates the state of the multishelf communications. Values can be:
• 1—No communications.
• 2—Communications are initializing.
• 3—Communications are initializing.
• 4—Operational.
Number of messages in queue but not yet sent.
Number of messages sent.
Number of messages received.
Number of retransmitted messages.
Number of seconds the shelf has been in the current state.
Number of times communications between the shelves have been established.
4-28 APX 8000/MAX TNT/DSLTNT Administration Guide
NetIF
Using Debug Commands
NetIF
Example: From a slave shelf: shelf-router-3/17>
msstat
SH State TxQs TxSeq RxSeq Resend Timer LinkUp
1 4 0 13693 13991 0 0 1
Note that on a slave shelf, only the master shelf is shown.
Description: Displays the TAOS unit’s network interface mappings.
Usage: netif -m -q -t -v -?
Syntax element
-m
-q
-t
-v
-?
Description
Display mappings for the specified map type.
Display the queue for a map.
Toggle debug display.
Display valid mapping tables.
Display this summary.
Example:
admin> netif -v map 0x1042C0E0: type 0 (call-id), id 0x1042B5A0 admin> netif -m 0
SHELF SLOT SysID SlotID
1 1 52 2
1 6 90 58
1 6 89 57
1 6 86 56
1 6 78 51
1 6 72 50
1 6 71 49
1 6 70 48
1 6 69 47
1 6 68 46
1 6 62 45
1 6 61 44
.
.
.
APX 8000/MAX TNT/DSLTNT Administration Guide 4-29
Using Debug Commands
PBecho
PBecho
Description: Tests the multishelf packet bus by using it to send traffic from one shelf controller to another.
The PBecho command is similar to Ping in that it sends a packet to a known destination and echoes the packet back. Because each cell contains a unique destination address to a shelf and slot within the system, you can test the packet bus by simply sending packets across it.
Usage:
pbecho
shelf slot count size
Syntax element
shelf slot count size
Description
Specifies the shelf to which to direct the echo packet.
Specifies slot to which to direct to the echo packet.
Specifies the number of packets to send.
Specifies the size of the packets to send.
PermConn-List
Description: Displays a list of all permanent connection profiles in the TAOS unit.
Usage: Enter
permconn-list
at the command prompt.
Pools
Example: In the following example, an administrator sends a thousand 1500-byte packets from the master shelf-controller to the slave shelf-controller in shelf 3: admin>
pbecho 3 17 1000 1500
pbus: Echo packets sent: 1000 rcvd: 1000 error: 0
The output of the command indicates that the slave controller received 1000 packets and echoed them back to the master shelf-controller. To further test the packet bus traffic across the multishelf system, the administrator could repeat the command a few times with different packet sizes, then, use the same command to send packets from the slave shelf-controller to the master.
Description: Displays a snapshot of a large selection of memory pools, the size of each pool, and the status of each pool. At the end of the list is a summary of the total memory allocation in the TAOS unit.
Memory is dynamically allocated to support various tasks, and should be freed when a particular task has been completed. Taking pools snapshots over an extended period of time can help troubleshoot a problem with a memory leak, in which memory is allocated for a task but never freed.
Snapshots should never show the entire quantity of allocated memory (or even any single pool) increasing over an extended period of time.
Usage: Enter
pools
at the command prompt.
4-30 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
Pools
Example: The number of pools displayed is usually very large. The following example displays just a portion of the typical output. admin>
pools
Pool Name size limit inUse hiWat heapAdrs
Accounting Session Change Registrants 8 0 1 1
103CCAE0
AcctEvnt 14 0 127 127 103CCAE0
AfsHashEntry 191 0 0 0 103CCBE0
AfsTaskMsg 219 0 0 0 103CCBE0
AssignedChannelPool 32 0 127 139 103CCAE0
AuthData 116 0 0 0 103CCBE0
BrouterPool 80 0 2 14 103CCB60
.
.
.
volatile profile instance 16 0 171 184 103CCAE0 volatile profile type info 12 0 7 7 103CCAE0
The first portion of the Pools command output includes the following fields:
Field Description
Pool name Pool name.
Size Size of the pool, in kilobytes.
Limit
InUse
Maximum number of buffers that can be allocated to a pool.
Number of pools in use.
HiWat
HeapAdrs
Highest number of pools allocated to a task since the TAOS unit was brought up.
Memory address of pool.
Following the list of pools, the Pools command displays a summary of memory usage:
total pools: 175
total buffers in use: 10593
total memalloc: 261685
total memfree: 258558
memalloc in use: 3129
memalloc failures: 0
memfree failures: 0
memalloc high water: 3146
Histogram of memalloc’d memory block sizes:
2659 buffers in range [64,127]
632 buffers in range [128,255]
2 buffers in range [256,511]
22 buffers in range [512,1023]
9 buffers in range [1024,2047]
21 buffers in range [2048,4095]
APX 8000/MAX TNT/DSLTNT Administration Guide 4-31
Using Debug Commands
PortInfo
3 buffers in range [4096,8191]
7 buffers in range [8192,16383]
6 buffers in range [32768,65535]
2 buffers in range [131072,262143]
1 buffers in range [262144,524287]
Total memory in use: 1295104 bytes in 3364 buffers
Histogram of free memory block sizes:
12 buffers in range [128,255]
1 buffers in range [256,511]
2 buffers in range [1024,2047]
1 buffers in range [1048576,2097151]
Total free memory: 1503680 bytes in 16 buffers
Following are descriptions of some of the more important fields in this display:
Field Description
total pools
Total number of pools in use.
total buffers in use
Number of buffers in use.
total memalloc total memfree
Total number of times the TAOS unit allocated a block of memory for use.
Total number of times the TAOS unit freed a block of memory. This should be fairly close to total memalloc. memalloc in use memalloc failures memfree failures memalloc high water
Total number of memory pools in use. This is the difference between total allocated and total freed.
Total number of times the TAOS unit failed to allocate a block of memory for use.
Total number of times the TAOS unit failed to free a block of memory.
The highest number of memory pools in use at any one time.
PortInfo
Description: Displays information about the TAOS unit’s ports.
Usage: portinfo port-number
Example:
admin>
portinfo 1
Printing fixed/allocated ports for slot 1
Linear Port: 1
- fixed: TRUE
- relative #: 0
- paired port: 65535
- slave: FALSE
- physical: FALSE
4-32 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
PPPdump
PPPdump
Description: Very similar to the WANdisplay diagnostic command. But the PPPdump command strips out escape characters that are present for asynchronous PPP users (who are dialing in with modems). The escape characters are necessary because of the asynchronous nature of the data stream. Stripping them out simply clarifies the presentation of the data.
If you enter the command while traffic streams heavily through your TAOS unit, the resulting amount of output can make it tedious to find the information you’re looking for. The screen might even display the message ----- data lost ----, which just means that not all the output can be displayed on the screen.
You might prefer to use the PPPdump command during a period of low throughput.
Usage: First open a session with a host card, then enter pppdump n where
n
is the number of octets to display per frame. Specifying a value of 0 (zero) disables the logging of this data.
Example: Following are two examples of the display of an asynchronous call, one produced by WANdisplay and the other by PPPdump.
The following frames were logged by entering
wandisplay 64
:
7E FF 7D 23 C0 21 7D 21 7D 21 7D 20 7D 37 7D 22 7D 26 7D 20 7D 2A 7D
20 7D 20 2D 7D 23 7D 26 3A AA 7E
7E FF 7D 23 C0 21 7D 21 7D 21 7D 20 23 7D 20 7D 24 7D 20 7D 20 7D 22
7D 7E
To get the data stream without escape characters, the 0x7D bytes need to be stripped, and the byte following each 0x7D byte needs to be decremented by 0x20.
With PPP dump, the data is automatically converted and displayed:
7E FF 03 C0 21 01 01 00 17 02 06 00 0A 00 00 2D 03 06 3A AA 7E 7E
FF 03 C0 21 01 01 00 23 00 24 00 00 02 7E
See Also: WANdisplay, WANnext, WANopen
PPPFSM
Description: Displays changes to the PPP state machine as PPP users connect. The command is a toggle that alternately enables and disables the debug display.
Usage: First open a session with a host card, then enter
pppfsm
at the command prompt.
Example: The following display shows the complete establishment of a PPP session: admin>
pppfsm
PPPFSM state display is ON
PPPFSM-97: Layer 0 State INITIAL Event OPEN...
PPPFSM-97: ...New State STARTING
PPPFSM-97: Layer 0 State STARTING Event UP...
PPPFSM-97: ...New State REQSENT
PPPFSM-97: Layer 1 State INITIAL Event UP...
PPPFSM-97: ...New State CLOSED
PPPFSM-97: Layer 2 State INITIAL Event UP...
APX 8000/MAX TNT/DSLTNT Administration Guide 4-33
Using Debug Commands
PPPinfo
PPPFSM-97: ...New State CLOSED
PPPFSM-97: Layer 3 State INITIAL Event UP...
PPPFSM-97: ...New State CLOSED
PPPFSM-97: Layer 4 State INITIAL Event UP...
PPPFSM-97: ...New State CLOSED
PPPFSM-97: Layer 5 State INITIAL Event UP...
PPPFSM-97: ...New State CLOSED
PPPFSM-97: Layer 6 State INITIAL Event UP...
PPPFSM-97: ...New State CLOSED
PPPFSM-97: Layer 7 State INITIAL Event UP...
PPPFSM-97: ...New State CLOSED
PPPFSM-97: Layer 8 State INITIAL Event UP...
PPPFSM-97: ...New State CLOSED
PPPFSM-97: Layer 9 State INITIAL Event UP...
PPPFSM-97: ...New State CLOSED
PPPFSM-97: Layer 0 State REQSENT Event RCONFREJ...
PPPFSM: irc_new scr 4
PPPFSM-97: ...New State REQSENT
PPPFSM-97: Layer 0 State REQSENT Event RCONFACK...
PPPFSM-97: ...New State ACKRECD
PPPFSM-97: Layer 0 State ACKRECD Event RCONFREQ...
PPPFSM-97: ...New State ACKRECD
PPPFSM-97: Layer 0 State ACKRECD Event RCONFREQ...
PPPFSM-97: Layer 1 State CLOSED Event OPEN...
PPPFSM-97: ...New State REQSENT
PPPFSM-97: ...New State OPENED
PPPFSM: PAP Packet
PPPFSM-97: Layer 6 State CLOSED Event OPEN...
PPPFSM-97: ...New State REQSENT
PPPFSM-97: Layer 4 State CLOSED Event OPEN...
PPPFSM-97: ...New State REQSENT
PPPFSM-97: Layer 4 State REQSENT Event RCONFREQ...
PPPFSM-97: ...New State REQSENT
PPPFSM: ccp Packet code 1
PPPFSM-97: Layer 6 State REQSENT Event RCONFREQ...
PPPFSM-97: ...New State REQSENT
PPPFSM: ccp Packet code 2
PPPFSM-97: Layer 6 State REQSENT Event RCONFACK...
PPPFSM-97: ...New State ACKRECD
PPPFSM-97: Layer 4 State REQSENT Event RCONFACK...
PPPFSM-97: ...New State ACKRECD
PPPinfo
Description: Displays information about established PPP sessions. The command has little practical use other than as a tool for developmental engineering.
Usage:
pppinfo index [ all ]
Syntax element
index
all
Description
Selects a particular PPP information table.
Displays information about embedded structures.
4-34 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
PPPstate
Example:
admin>
pppinfo 1
Ncp[LCP] = B02B396C
Ncp[AUTH] = B02B39BC
Ncp[CHAP] = B02B3A0C
Ncp[LQM] = B02B3A5C
Ncp[IPNCP] = B02B3AAC
Ncp[BNCP] = B02B3AFC
Ncp[CCP] = B02B3B4C
Ncp[IPXNCP] = B02B3B9C
Ncp[ATNCP] = B02B3BEC
Ncp[UNKNOWN] = B02B3C3C
Mode = async nOpen pending = 0
LocalAsyncMap = 0
RemoteAsyncMap = 0
Peer Name = N/A
Rmt Auth State = RMT_NONE aibuf = 0 ipcp = B03E502C vJinfo = 0 localVjInfo = 0 bncpInfo = B03E559C ipxInfo = B03E55DC remote = no
Bad FCS = a
PPPstate
Description: Displays the state of a PPP connection. Different PPP calls can be routed (call routing, as opposed to IP or IPX routing) through a TAOS unit differently. The command is a toggle that alternately enables and disables the debug display.
The command has little practical use other than as a tool for developmental engineering.
Usage: Enter
pppstate
at the command prompt.
Example: The following message indicates that data is moved directly from the WAN to the
Ethernet segment. WAN data can be redirected to other resources (X.75 handler or V.120 handler) before it is ready to be sent to the Ethernet segment.
PPP-116: Redirect async wan direct
PRIdisplay
Description: Displays all ISDN PRI D-channel signaling packets that are either received or sent through the PRI interfaces.
Usage: To use this command, first open a session with a network card configured for PRI signaling (for example, a T1 or E1 card). Then enter the PRIdisplay command. The command uses the following syntax:
APX 8000/MAX TNT/DSLTNT Administration Guide 4-35
Using Debug Commands
RADacct
pridisplay number-of-octets-to-display line
Syntax element Description
number-of-octets-to-display
Specifies the number of octets in the PRI messages to display. Specify 0 (zero) to disable the display.
line
The PRI line to display. Specify 0 (zero) to display any line.
Example:
e1-1/15>
pridisplay 128 0
Display the first 128 bytes of PRI messages e1-1/15> PRI-XMIT-7: 10:37:00: 4 of 4 octets
800F1020: 00 01 01 73 ...s
PRI-RCV-7: 10:37:00: 4 of 4 octets
800F3CA0: 00 01 01 73 ...s
PRI-XMIT-7: 10:37:10: 4 of 4 octets
800F1020: 00 01 01 73 ...s
PRI-RCV-7: 10:37:10: 4 of 4 octets
800F3CA0: 00 01 01 73 ...s
PRI-XMIT-7: 10:37:20: 4 of 4 octets
800F1020: 00 01 01 73 ...s
PRI-RCV-7: 10:37:20: 4 of 4 octets
800F3CA0: 00 01 01 73 ...s
PRI-XMIT-7: 10:37:30: 4 of 4 octets
800F38E0: 00 01 01 73 ...s
PRI-RCV-7: 10:37:30: 4 of 4 octets
800F3CE0: 00 01 01 73 ...s
pridisplay 0
PRI message display terminated
RADacct
4-36
Description: Displays RADIUS accounting information. The RADacct command displays very few messages if RADIUS Accounting is functioning correctly.
(RADif
displays more detailed information for troubleshooting RADIUS-related issues.) The RADacct command is a toggle that alternately enables and disables the debug display.
Usage: Enter
radacct
at the command prompt.
Example:
admin>
radacct
RADACCT debug display is ON
A user hangs up and a stop record is generated.
RADACCT-147:stopRadAcct
The following message indicates that there is some load on the network, and the sending of a stop record is delayed. This is not necessarily an indication of a problem.
RADACCT-147:_endRadAcct: STOP was delayed
APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
RADif
RADif
Description: Displays RADIUS-related messages. RADif is a powerful diagnostic command, because it displays RADIUS messages the TAOS unit receives as well as messages that it sends. Output from
RADif
, in conjunction with running your RADIUS daemon in debug mode (using the
-x
option), gives you virtually all the information you need to clarify issues relating to user authentication.
You can also validate the IP port that you have configured (or think you have configured), and the user name that is being sent by the client.
The command is a toggle that alternately enables and disables the debug display.
Usage: Enter
radif
at the command prompt.
Example: Following are messages you might see for a successful RADIUS authentication:
RADIF: authenticating <8:my_name> with PAP
RADIF: _radiusRequest: id 41, user name <9:my_name>
RADIF: _radiusRequest: challenge len = <0>
The IP address and RADIUS Daemon Authentication port are displayed:
RADIF: _radiusRequest: socket 5 len 89 ipaddr 01010101 port
65534->1645
RADIF: _radCallback
RADIF: _radCallback, buf = B05BBFA0
The response is sent back from RADIUS. In this case, the user my_name has passed authentication. Following is a list of the most common responses:
1 - Authentication Request
2 - Positive acknowledgement
3 - Rejection
4 - Accounting request
5 - Accounting response
7 - Password change request
8 - Password change positive acknowledgement
9 - Password change rejection
11 - Access challenge
29 - Password - next code
30 - Password New PIN
31 - Password Terminate Session
32 - Password Expired
RADIF: _radCallback, authcode = 2
RADIF: Authentication Ack
After, authenticating a user, the RADIUS daemon sends the attributes from the user profile to the TAOS unit. The TAOS unit creates the user’s Connection profile from these attributes, and
RADif displays them. (See the TAOS RADIUS Guide and Reference for a complete list of attribute numbers.)
RADIF: attribute 6, len 6, 00 00 00 02
RADIF: attribute 7, len 6, 00 00 00 01
RADIF: attribute 8, len 6, ff ff ff fe
RADIF: attribute 9, len 6, ff ff ff 00
RADIF: attribute 11, len 12, 73 74 64 2e
APX 8000/MAX TNT/DSLTNT Administration Guide 4-37
Using Debug Commands
RADservdump
RADIF: attribute 12, len 6, 00 00 05 dc
RADIF: attribute 10, len 6, 00 00 00 00
RADIF: attribute 13, len 6, 00 00 00 01
RADIF: attribute 244, len 6, 00 00 11 94
RADIF: attribute 169, len 6, 00 00 11 94
RADIF: attribute 170, len 6, 00 00 00 02
RADIF: attribute 245, len 6, 00 00 00 00
RADIF: attribute 235, len 6, 00 00 00 01
A RADIUS Accounting Start packet is sent to the RADIUS Accounting Server (using port
1646):
RADIF: _radiusAcctRequest: id 42, user name <9:my_name>
RADIF: _radiusAcctRequest: socket 6 len 82 IP cf9e400b port 1646,
ID=42
RADIF: _radCallback
RADIF: _radCallback, buf = B05433C0
RADIF: _radProcAcctRsp: user:<9:my_name>, ID=42
RADservdump
Description: Use this command to verify the configuration you have set in the External-Auth profile.
Usage: Enter
radservdump
at the command prompt.
This does not display any information related to the configuration of either your RADIUS
Authentication server or your RADIUS Accounting server.
Example: For the following example, the TAOS unit has been configured with two RADIUS servers, 1.1.1.1 and 2.2.2.2. The port has not been changed from its default of 1700.
admin> radservdump
Rad serv vars: port=1700,sockId=8
0) clients=1010101
1) clients=2020202
2) clients=0
3) clients=0
4) clients=0
5) clients=0
6) clients=0
7) clients=0
8) clients=0
RADsessdump
Description: Displays the state of all RADIUS Accounting sessions.
Usage: Enter
radsessdump
at the command prompt.
Example:
admin> radsessdump
RadActSess: state route sessID nasPort authM evTime
loadd 00289 252365175 012032 local 523932
4-38 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
RADstats
loadd 00288 252365174 012032 local 523946
loadd 00287 252365173 012032 local 523945
loadd 00286 252365172 012032 local 523946
loadd 00227 252355493 012032 local 370610
loadd 00226 252355492 012032 local 370611
loadd 00225 252355491 012032 local 370608
loadd 00224 252355490 012032 local 370609
loadd 00004 252332182 012032 none 29
loadd 00003 252332181 012032 none 28
loadd 00002 252332180 012032 none 27
loadd 00001 252332179 012032 none 26
The RADsessdump command displays the following information:
Column Name:
Route
SessID
NASPort authM evTime
Description
Internal route ID.
Session ID. This depends on the route ID.
Statistics about the call. The first two digits indicate the type of call:
1 indicates a digital call, 2 indicates an analog call. The next two digits indicate the line on which the call was received. The last two digits indicate the channel on which the call was received.
Method of authentication.
Event time. This is a time stamp.
RADstats
Description: Displays a compilation of RADIUS Authentication and Accounting statistics.
Usage: Enter radstats
at the command prompt.
Example:
admin> radstats
RADIUS authen stats:
In the following message, A denotes Authentication. O denotes Other. There were 612
Authentication requests sent and 612 Authentication responses received:
0 sent[A,O]=[612,15], rcv[A,O]=[612,8]
602 were authenticated successfully, and 18 were not: timout[A,O]=[0,6], unexp=0, bad=18, authOK=602
In the next message, the IP address of the RADIUS server is 1.1.1.1, and the curServerFlag
indicates whether or not this RADIUS server is the current authentication server. (You can have several configured RADIUS servers, but only one is current at any one time.)
0
indicates no.
1
indicates yes.
IpAddress 1.1.1.1, curServerFlag 1
RADIUS accounting stats:
APX 8000/MAX TNT/DSLTNT Administration Guide 4-39
Using Debug Commands
Reset
The next message indicates that the TAOS unit sent 1557 Accounting packets and received
1555 responses (
ACKs
from the Accounting server). Therefore, the unexp
value is
2
. This is not necessarily an indication of a problem, but might be the result of the TAOS unit timing out a particular session before receiving an
ACK
from the RADIUS server. Momentary traffic load might cause this condition. The value of bad
is the number of packets that were formatted incorrectly by either the TAOS unit or the RADIUS server.
0 sent=1557, rcv=1555, timout=0, unexp=2, bad=0
In the next message, note that the Accounting server is different from the Authentication server. The Accounting and Authentication servers do not need to be running on the same host, although they can be.
IpAddress 2.2.2.2, curServerFlag 1
Local Rad Acct Stats:
The next two messages can be used to look for traffic congestion problems or badly formatted
Accounting packets. Under typical conditions, you might see a few packets whose acknowledgments fail.
The following message indicates whether any RADIUS requests have been dropped by the
TAOS unit. With this particular message, no requests were dropped. 1557 were sent successfully.
nSent[OK,fail]=[1557,0], nRcv=1557, nDrop[QFull,Other]=[0,0]
The following message indicates whether any session timeouts resulted from failure to receive
RADIUS responses. The message also indicates responses that are received by the TAOS unit but do not match any expected responses. The TAOS unit keeps a list of sent requests, and expects a response for each request. In the following message, one response was received from the RADIUS server that did not match any of the requests that the TAOS unit had sent out.
This might be caused by a corrupted response packet, or by the TAOS unit timing out the session before the response was received.
nRsp[TimOut,NoMatch]=[0,1], nBackoff[new,norsp]=[0,0]
The following messages display a summarized list of RADIUS server statistics.
Local Rad Serv Stats: unkClient=0 index 0 #Sent = 0, #SendFail=0 badAuthRcv = 0, badPktRcv = 0
Reset
Description: This command resets the TAOS unit. When you reset the unit, it restarts and all active connections are terminated. All users are logged out and the default security level is reactivated. In addition, any active WAN lines are temporarily shut down due to loss of signaling or framing information. After a reset, the TAOS unit runs POST (power-on self-tests).
Usage: reset
Example: To reset the unit: admin>
reset
See Also: NVRAM
4-40 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
Resrcmgr
Resrcmgr
Description: Displays the information from the TAOS unit’s shelf controller.
Usage: Enter
resrcmgr
at the command prompt.
Example: The following syntax is supported.
admin> ? resrcmgr usage: resrcmgr -i|u|?
-i list resource (i)tem information
-u list resource (u)sage information
-? display this summary
Revision
Description: Displays the serial number of the box.
Usage: Enter
revision
at the command prompt.
Example: In the following message,
7172461
is the serial number of the TAOS unit.
admin> revision revision = 0 1 10 7172461
RoutMgr
Description: Displays information about the routing of incoming calls to either the Ethernet or modem ports. RoutMgr, when used in conjunction with Networki, can show valuable call routing information. If you have problems with users not connecting, and the incoming calls disconnect within one or two seconds of being presented to the TAOS unit , use RoutMgr and
Networki to look for possible clues.
The command is a toggle that alternately enables and disables the debug display.
Usage: Enter
routmgr
at the command prompt.
Example:
admin>
routmgr
ROUTMGR debug is now ON
ROUTMGR: buildIncomingRoute, port 0, phone <4990>
ROUTMGR: routMgrTask routeID=106, port=0, phone=4990
ROUTMGR-106: _matchPhoneNumber
There are no port limitations configured in the T1 profile:
ROUTMGR-106: _matchAnyPort
The next two messages show that the Bearer Capability in the ISDN setup message for the call indicates that it is a voice call, and that the call is routed to an available modem:
ROUTMGR-106: voice call
ROUTMGR: giving call to lan/hostif
At this point, the call is passed to other TAOS unit functions to continue the connection setup.
Following is output from RoutMgr when a call is cleared.
APX 8000/MAX TNT/DSLTNT Administration Guide 4-41
Using Debug Commands
SAR
ROUTMGR: destroyRoute routeID = 106, cause = CLEAR
ROUTMGR-106: port is 59
ROUTMGR: deallocateCapabilityrouteID=106, capability=ALL
ROUTMGR: route 106 destroyed
SAR
Description: Shows packet bus statistics. Packet-bus traffic enters and exits a slot card (and shelf controller) by means of a chip called a SAR.
Usage: sar -option
Where
-option
is one of the following:
Option
-s
-s -a
-s -i shelf slot
-s -m
-c
-c -a
-c -i shelf slot
-v shelf slot
-l
-y
-z
Description
Show SAR errors.
Show all statistics.
Show SAR statistics for the indicated shelf and slot.
Show SAR memory partition.
Clear global statistics.
Clear all statistics.
Clear statistics for indicated shelf and slot.
Display the SAR virtual circuit table for the specified shelf and slot.
List open channels.
Loop back cell statistics (shelf controller only).
Send loopback cell (shelf controller only).
Example:
In the following example, an administrator checks for SAR errors and finds that there are none.
ad min> sar -s
Ver RxAlrt RxStop RxRstrt NoRxBuf bsPrErr cmPrErr busErr NoTxMBx NoRxMBx s
8
0 0 0 0 0 0 0 0 0 6
In the next example, the administrator displays all the SAR statistics for the system: admin>
sar -s -a
SH/SL Tx TxDone TxNoBuf Rx RxErr RxUnFlow RxOvRun a
1/ 1 8 8 0 5816 0 0 0 0
1/11 736947 736947 0 736473 0 0 0 0
1/16 27637 27637 0 27494 0 0 0 0
1/17 160 160 0 160 0 0 0 0
1/19 174588 174588 0 174588 0 0 0 0
2/21 822669 822669 0 822653 4 0 0 0
3/21 1109332 1109332 0 1109301 5 0 0 0
4-42 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
SNTP
4/21 145403 145403 0 0 0 0 0 0
5/21 145403 145403 0 0 0 0 0 0
6/21 145403 145403 0 0 0 0 0 0
7/21 145403 145403 0 0 0 0 0 0
8/21 145403 145403 0 0 0 0 0 0
9/21 145403 145403 0 0 0 0 0 0
In the following example, the administrator displays SAR statistics for shelf 1, slot 17 (the master shelf-controller).
admin> sar -s -i 1 17
SH/SL Tx TxDone TxNoBuf Rx RxErr RxUnFlow
RxOvRun a
1/17 160 160 0 160 0 0 0
0
SNTP
Description: Displays messages related to the Simple Network Time Protocol (SNTP) functionality of the TAOS unit. The command is a toggle that alternately enables and disables the debug display.
Usage: Enter
sntp
at the command prompt.
Example: Following are three examples of messages displayed with SNTP enabled.
The TAOS unit accepts time from a configured NTP server. The following message appears if the TAOS unit does not accept a supplied time:
Reject:li= x stratum= y tx= z
The following message indicates that the TAOS unit accepts the time from a specified NTP server:
Server= 0 Time is b6dd82ed d94128e
Because the stored time is off by more than one second, it is adjusted:
SNTP: x Diff1= y Diff2= z
StackLimit
Description: If any TAOS unit function uses all but 128 or fewer of the bytes available for the stack, this command enables a checking routine that logs a warning to the Fatal-History log.
The command is a toggle that alternately enables and disables the debug display.
Description: This command will enable a checking routine that will log a warning to the
Fatal-History log whenever any TAOS unit’s function usage gets within 128 bytes from the end of the stack. The command is a toggle that alternately enables and disables the debug display.
Usage: Enter
stacklimit
at the command prompt.
APX 8000/MAX TNT/DSLTNT Administration Guide 4-43
Using Debug Commands
TDM
TDM
-s
-l
-t
-u
-?
-c
-d
-f
-r
Description: Used to set up or query the TDM bus.
Usage: tdm
[-option ] [
itemA itemB
] [
connectionId
] where
-option
is one of the following:
Option
-a
Description
Allocate by first available. (Used when setting up a TDM connection to test).
Connect channels.
Disconnect a channel.
Allocate a TDM channel by round robin.
Display TDM manager statistics.
List all connections.
Toggle TDM manager debug output.
Display TDM channel usage statistics.
Display this summary.
The other syntax elements are:
Element
-x number
itemA itemB connectionID
Description
Set the next TDM channel to check.
Logical address to connect from.
Logical address to connect to.
ID of connection to disconnect.
Example: Following are some examples of output from the TDM command. admin>
tdm -l
--id-- --cstate-- cnt tdm# ---src(A)--- ---dst(B)---
1 connected 8 32 01:02:04/001 01:11:01/001
33 01:02:04/002 01:11:01/002
34 01:02:04/003 01:11:01/003
35 01:02:04/004 01:11:01/004
36 01:02:04/005 01:11:01/005
37 01:02:04/006 01:11:01/006
38 01:02:04/007 01:11:01/007
39 01:02:04/008 01:11:01/008
2 connected 24 40 01:02:06/001 01:11:01/009
41 01:02:06/002 01:11:01/010
42 01:02:06/003 01:11:01/011
43 01:02:06/004 01:11:01/012
4-44 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
TDMtst
admin>
tdm -s
Number of total connections: 9
Number of active connections: 9
Number of available channels: 839
Number of used channels: 185
Number of disconnection errors: 0
Number of bad received messages: 0
Number of invalid events: 0
Number of missing connections: 0
Number of bad events: 0
Number of bad states: 0 admin>
tdm -u
(non-empty entries ONLY)
timslot nUsed --currSrc--- --currDst---
32 1 01:02:04/001 01:11:01/001
33 1 01:02:04/001 01:11:01/001
34 1 01:02:04/001 01:11:01/001
35 1 01:02:04/001 01:11:01/001
36 1 01:02:04/001 01:11:01/001
37 1 01:02:04/001 01:11:01/001
38 1 01:02:04/001 01:11:01/001
39 1 01:02:04/001 01:11:01/001
40 1 01:02:06/001 01:11:01/009
.
.
.
TDMtst
Description: TDMtst runs on the HDLC card and tests the TDM bus. You can use it to verify communication between HDLC cards. Because the command tests byte-stream communication on the TDM bus, which must use a known time slot, it requires some setup before it can verify TDM traffic.
Usage: tdmtst
-option where
-option
is one of the following:
Option
-o channel
physical-address logical-address
-c channel
-e channel count size
-b channel count size
Description
Open a TDM channel between the physical address and the logical address.
Close the TDM channel.
Send packets across the TDM bus on the open channel.
Send packets across the TDM bus on the open channel.
APX 8000/MAX TNT/DSLTNT Administration Guide 4-45
Using Debug Commands
TelnetDebug
Option
-x channel string
-s
-t
TelnetDebug
Description
Send the specified string over the TDM channel.
Display the TDM test statistics.
Toggle debug level.
Description: Displays messages as Telnet connections are attempted or established. The
Telnet protocol negotiates several options as sessions are established, and TelnetDebug displays the Telnet option negotiations.
The command is a toggle that alternately enables and disables the debug display.
Usage: Enter
telnetdebug
at the command prompt.
Example: The following session shows a successful Telnet connection from the TAOS unit’s terminal server to another UNIX host.
admin>
telnetdebug
TELNET debug is now ON
The far-end UNIX host has been contacted:
TELNET-4: TCP connect
For this Telnet session, the TAOS unit will support options 24 and 1. The UNIX host should respond with either
DO
or
WONT
:
TELNET-4: send WILL 24
TELNET-4: recv WILL 1
The UNIX host will support option 1:
TELNET-4: repl DO 1
The TAOS unit receives a request to support option 3:
TELNET-4: recv WILL 3
The TAOS unit will support option 3:
TELNET-4: repl DO 3
The UNIX host will support option 3:
TELNET-4: recv DO 3
The UNIX host will not support option 24:
TELNET-4: recv DONT 24
The TAOS unit will not support option 24:
TELNET-4: repl WONT 24
The UNIX host will support options 1 and 3:
4-46 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
TNTMP
TELNET-4: recv WILL 1
TELNET-4: recv WILL 3
TNTMP
Description: Displays information about MP and MP+ bundles and their channels. You can execute the TNTMP command on a shelf controller or on an HDLC card. You must first execute the Open command to open a session with the card.
Permission level: Debug
Usage: tntmp -i
Example: To display information about MP and MP+ bundles and their channels: admin> tntmp -i mpBundleID=13 masterSlot=1/15 masterMpID=2 ifCount=2 rtIf=1/17:6
routeID slot ifNum localIfNum localMpID
32 1/15 1 1 2
33 9/ 2 193 1 2
This command works on HDLC cards as well. First, open a session with HDLC card, and then execute the TNTMP command. For example: admin> open 1 15 hdlc-1/15> tntmp -i mpBundleID=13 masterSlot=1/15 masterMpID=2 ifCount=2 rtIf=1/17:6
routeID slot ifNum localIfNum localMpID
32 1/15 1 1 2
33 9/ 2 193 1 2
In this example, the output shows a two-channel MP or MP+ bundle, with the first channel in slot 1/15 and the second (slave) channel in slot 9/2.
The command displays the following information:
Field
mpBundleID masterSlot masterMpID ifCount rtIf routeID
Description
The globally known bundle ID for the whole system. If the connection adds channels for additional bandwidth on demand, the call for those channels is compared to the current bundle and assigned the same bundle ID as the other channels of the call.
The channel that was established as the base channel of the connection. After the TAOS unit authenticates a call that is not part of an existing bundle, it establishes the base channel of the connection. That channel becomes the master of the multilink connection.
The bundle ID at the master slot card. (The masterMpID is always the same as the localMpID for channels on the master slot card.)
The number of channels in the bundle.
The shelf/slot:id for the Route Logical Interface.
The globally known ID for each call.
APX 8000/MAX TNT/DSLTNT Administration Guide 4-47
Using Debug Commands
TSshow
Field
slot ifnum localIfNum localMpID
Description
The shelf/slot numbers of the channels in the MP or MP+ bundle.
Channel number on the master slot card.
The channel number on the local slot card. For HDLC cards, the channels are numbered 1–192. In the output in the example, the master slot
(1/15) shows channel number 1. The interface number for the slave slot (9/2) is also 1, meaning the first channel on that card. However, at the master slot card, the slave interface number is mapped to a pseudo-interface number greater than 192, so it is not confused with channels on the master slot.
The bundle ID known locally to the slot card.
TSshow
Description: Displays uptime and revision information about the TAOS unit. The Uptime command and the Software-Version parameter display the same information.
Usage:
tsshow [ ? ] [
uptime
] [
revision
]
Syntax element:
?
uptime revision
Description:
List all options.
Display system uptime.
Display software and version currently running.
Example: Following are some samples of TSshow output: admin> tsshow
Show what? Type ’tsshow ?’ for help.
admin> tsshow ? tsshow ? Display help information tsshow uptime Display system uptime.
tsshow revision Display system revision.
admin> tsshow uptime system uptime: up 36 days, 9 hours, 59 minutes, 27 seconds admin> tsshow revision system revision: tntsr 2.0.0
TunnelDebug
Description: Displays messages related to setting up Generic Routing Encapsulation (GRE) tunnels on the TAOS unit. The command is a toggle that alternately enables and disables the debug display.You would normally use this command with the ATMPdebug command.
Usage: Enter
tunneldebug
at the command prompt.
Example: The following example shows an ATMP tunnel being set up:
4-48 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
TunnelSlot
TUNNELTNT.CB[1/7]: Event=Start-Tunnel SN=80
TUNNELTNT[1/7]: DUMP [Start-Tunnel] SN=80 MC=1/17/24/10052400
HN=[] priHA=[200.67.1.254] secHA=[] Udp=5150 pass=[ascend]
IP=141.111.40.55 Mask=255.255.255.255 IPX=00000000:000000000000
TUNNEL: createFAsession: priHA=[200.67.1.254] secHA=[] udpPort=5150
ifNum=1/17/24/10052400 MajDev=7 password=ascend
mcIpAddr=141.111.40.55/32
TUNNEL-411: Alloc 1019F660 Id=411 TN=411
TUNNEL-411: resolving 200.67.1.254, port=5150, SN=411
TUNNEL-START: In progress
TUNNELTNT[1/7]: DUMP [Start-Tunnel-Rsp] SN=411 MC=1/7/4/10059440
LocalSN=80 GlobalSN=411 Status=In progress
TUNNEL: _dnsCallback: name=[200.67.1.254], ip=200.67.1.254 DNS=411
TUNNEL-411: tunnelSetStatus: status=Good completion
TUNNELTNT[1/7]: DUMP [Update-Tunnel] SN=411
TunnelNumber=405 mcRtIf=1/7/4/10059440 HomeRtIf=0/0/0/0
HomeAgent=200.67.1.254:5150 HomeNetwork=[] Flags=10 AgentMode=2
IP=141.111.40.55 Mask=255.255.255.255 IPX=00000000:000000000000
TUNNELTNT[1/7]: DUMP [Set-Status] SN=411 ErrorCode=0
TUNNELTNT[1/7]: DUMP [Start-Tunnel-Rsp] SN=411 MC=1/7/4/10059440
LocalSN=80 GlobalSN=411 Status=In progress
TunnelSlot
Description: The command has little practical use other than as a tool for developmental engineering.
Update
Description: Modifies optional functionality of the TAOS unit. To enable some options, you must obtain a set of hash codes (supplied by a Lucent Technical Support representative) that will enable the functionality in your TAOS unit. After each string is entered, the word complete appears, indicating that the TAOS unit accepted the hash code.
If you enter update
without a text string modifier, the TAOS unit displays a list of current configuration information.
Usage:
update [ text_string ]
Example:
admin>
update
Host interfaces: 4
Net interfaces: 4
Port 1 channels: 255
Port 2 channels: 255
Port 3 channels: 255
Port 4 channels: 255
Field features 1: 182
Field features 2: 33
Field features 3: 54
Protocols: 1
APX 8000/MAX TNT/DSLTNT Administration Guide 4-49
Using Debug Commands
WANdisplay
admin> update 5 1023 12321312312312321
The following two messages indicate that the text strings were entered incorrectly: update command: invalid arg 3!
update command: disallowed
The following message indicates that the TAOS unit accepted the update string: update command: command complete.
WANdisplay
Description: Displays all packets received from, or sent to any of the WAN interfaces.
Because WANdisplay output shows what the TAOS unit is receiving from and sending to the remote device, the information can be very helpful in resolving PPP negotiation problems.
If you enter the command on your TAOS unit while traffic is heavy, the resulting amount of output can make it tedious to find the information you are looking for. The screen might even display the message
----- data lost -----
, which means that not all output can be displayed on the screen.
Depending on the types of information you need to gather, you might prefer to use the
WANdisplay command during a period of low throughput, or to use WANdsess, WANopen or
WANnext to focus the display.
Usage: wandisplay number-of-octets-to-display
Enter
wandisplay 0
to disable the logging of this information.
Example: Following are several examples of WANdisplay output. Note that the bytes are displayed in hexadecimal format.
admin> wandisplay 24
Display the first 24 bytes of WAN messages
> RECV-272:: 1 octets @ 5E138F74
[0000]: 0D
RECV-272:: 13 octets @ 5E13958C
[0000]: 0A 41 63 63 65 70 74 3A 20 69 6D 61 67
XMIT-276:: 1011 octets @ 2E12D8A4
[0000]: 7E 21 45 00 03 EE 54 2B 40 00 37 06 BA 09 CF 2B
[0010]: 00 86 D0 93 91 90 1A 0A admin> wandisplay 0
WAN message display terminated
WANdsess
Description: Shows WAN data as it is received and transmitted for a particular user. The
WANdsess command is very similar to the WANdisplay command, but when you use
WANdsess, the TAOS unit displays only incoming and outgoing packets for a specific user.
WANdsess is particularly helpful on a TAOS unit with several simultaneous active connections. The command acts as a filter, allowing you to focus your troubleshooting.
Use the WANdsess command with host cards only. You must first execute the Open command to open a session with the modem or HDLC card.
4-50 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
WanEventsStats
Usage: wandsess session-name octets
Syntax element session-name octets
Description
Name of a local Connection profile or a RADIUS user profile.
Maximum number of octets to display per packet. If you specify 0
(zero), the TAOS unit does not display any data.
Example: To open a session with a modem card, and activate the display of WAN data for
Tim’s sessions: admin>
open 1 7
modem-1/7>
wandsess tim
RECV-tim:300:: 1 octets @ 3E13403C
[0000]: 7E 21 45 00 00 3E 15 00 00 00 20 7D 31 C2 D2
RECV-tim:300:: 15 octets @ 3E133A24
[0000]: D0 7D B3 7D B1 B3 D0 7D B3 90 02 04 03 00 35
XMIT-tim:300:: 84 octets @ 3E12D28C
[0000]: 7E 21 45 00 00 4E C4 63 00 00 1C 7D 31 17 5F D0
[0010]: 93 90 02 D0 93 91 B3 00
Note that the bytes are displayed in hexadecimal format.
See Also: WANdisplay, WANopening
WanEventsStats
Description: Displays statistics about WAN events of interest on a host card.
Usage: First, open a session to a host card, then enter
waneventstats
at the command prompt.
Example:
modem-1/2>
wanEventStats
Output:
_sendCachedData() Counts:
NullWanInfo 0
BufLen: 0
NullHandle: 0
BadState: 0
QueuingFails: 0
ToMbufFails: 0
SendOk: 0
_loseCachedData() Counts:
NoBuf: 0
LoseOk: 0
_cachePrioData() Counts:
BadData: 0
MallocFails: 0
PrevCache: 0
CacheOk: 0
APX 8000/MAX TNT/DSLTNT Administration Guide 4-51
Using Debug Commands
WanEventsStats
WanInfo Instance Error Counts:
_wanBufferSent: 0
_wanBufferRcvd: 0
_wanBreakRcvd: 0
_modemEventHandlerInstanceMismatch: 0
WanInfo TxPending Error Counts: 0 wanSendData() Counts:
_wanSendDataOk: 1fd2e
_wanSendDataHighPriority: 1fd2e
_wanSendDataNormPriority: 0
_wanSendDataNoInpMbuf: 0
_wanSendDataBadLen: 0
_wanSendDataNormPrioNoBuf: 0
_wanSendDataNoRoute: 0
In this output, the following counters should always be set to zero (a non-zero value indicates an error condition):
NullWanInfo 0
BufLen: 0
NullHandle: 0
BadState: 0
NoBuf: 0
BadData: 0
_wanBufferSent: 0
_wanBufferRcvd: 0
_wanBreakRcvd: 0
_modemEventHandlerInstanceMismatch: 0
WanInfo TxPending Error Counts: 0
_wanSendDataNoInpMbuf: 0
_wanSendDataBadLen: 0
The rest of the counters can have non-zero values, although most of them indicate how busy the system is and should have small values. For example, the following counters record high-priority message caching events:
SendOk: 0
LoseOk: 0
CacheOk: 0
The next counters record send message requests. These are the only counters that record normal events rather than errors. The first _wanSendDataOk counter represents the count of all
HDLC packets sent out, which may be quite a large number. The other two counters represent the two types of HDLC data, normal and high priority. Their sum should equal the value of
_wanSendDataOk in the absence of errors. For example:
_wanSendDataOk: 1fd2e
_wanSendDataHighPriority: 1fd2e
_wanSendDataNormPriority: 0
The next counter records dropped normal priority messages. A non-zero value indicates the number of normal messages dropped due to lack of a buffer. To some extent this indicates how
4-52 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
WANopening
busy the system is, but because sessions have a buffer quota, it is possible to drop a normal message and increment this counter even when the system is not overloaded and when it is not out of buffers.
_wanSendDataNormPrioNoBuf: 0
The next counter reports requests to send a packet being processed after the session has been terminated. This is a normal occurrence when a call terminates during data transfer. (Its value should normally be relatively small but not necessarily non-zero.)
_wanSendDataNoRoute: 0
The following counters record the system’s inability to obtain a DRAM or HDLC buffer for high priority message caching:
QueuingFails: 0
ToMbufFails: 0
MallocFails: 0
The following counter records high priority messages that have been dropped from the cache due to the arrival of another high priority message for the same session:
PrevCache: 0
WANopening
Description: Shows WAN data as it is received and transmitted during connection establishment for all users. The WANopening command is particularly helpful for troubleshooting connection problems in which users make the initial connection, but are disconnected within a few seconds. The output of WANopening is very similar to the output of
WANdisplay, but WANopening only shows packets until the connection has been completely negotiated.
Use the WANopening command with host cards only. You must first execute the Open command to open a session with the modem or HDLC card.
Usage:
wanopening octets
The
octets
value specifies the maximum number of octets to display per packet. If you specify 0 (zero), the TAOS unit does not log WAN data
Example: To open a session with a modem card, and activate the display of WAN data received and transmitted during connection establishment: admin>
open 1 7
modem-1/7>
wanopening
Display the first 24 bytes of WAN messages
RECV-272:: 1 octets @ 5E138F74
[0000]: 0D
RECV-272:: 13 octets @ 5E13958C
[0000]: 0A 41 63 63 65 70 74 3A 20 69 6D 61 67
XMIT-276:: 1011 octets @ 2E12D8A4
[0000]: 7E 21 45 00 03 EE 54 2B 40 00 37 06 BA 09 CF 2B
[0010]: 00 86 D0 93 91 90 1A 0A
APX 8000/MAX TNT/DSLTNT Administration Guide 4-53
Using Debug Commands
WANtoggle
Note that the bytes are displayed in hexadecimal format.
See Also: WANdisplay, WANdsess
WANtoggle
Description: Displays messages from the WAN drivers on the TAOS unit, including the status of calls that are passed from the TAOS unit’s call routing routines as the connection is prepared to be passed to the Ethernet drivers.
If you enter the command while traffic through your TAOS unit is heavy, the resulting amount of output can make it tedious to find the information you are looking for. The screen might even display the message
----- data lost -----
, which just means that not all the output can be displayed on the screen. You might prefer to use this command during a period of low throughput.
The command is a toggle that alternately enables and disables the debug display.
Usage: Enter
wantoggle
at the command prompt.
Example: Following is a typical example of output produced by a modem call into the TAOS unit. After the incoming call is determined to be an analog call, a modem is directed to answer it.
WAN-389: wanOpenAnswer
WAN-389: modem redirected back to wan
WAN-389: Startup frame received
WAN-389: Detected unknown message
WAN-389: Detected ASYNC PPP message
WAN-389: wanRegisterData, I/F 58
The next two messages appear when the call is cleared.
WAN-389: wanCloseSession, I/F 58
The last message is not an indication of a problem. The modem clears the call a split second before the software releases its resources. The software does a check on the modem, which has already been released. This message is not an indication of a problem.
WAN-??: no modem assoc w WanInfo
4-54 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Debug Commands
Special administrative debug commands
Special administrative debug commands
Generating warning messages from a Coredump server
When coredumps are set up and enabled, you can specify an additional range of warning messages that will cause a coredump. The following new parameters (shown with default values) enable you to specify an additional range of Warning message index values to cause a coredump:
[in DEBUG/{ any-shelf any-slot 0 }] min-warning-core-dump = 0 max-warning-core-dump = 0
Parameter Specifies
Min-Warning-Core-Dump Minimum Warning message index value to cause a coredump.
This value must be less than or equal to the
Max-Warning-Core-Dump value. The default zero means that only
Warnings from 101 to 121 cause a coredump. The valid range is from 1 to 9999.
Max-Warning-Core-Dump Maximum Warning message index value to cause a coredump.
This value must be greater than or equal to the
Min-Warning-Core-Dump value. The default zero means that only
Warnings from 101 to 121 cause a coredump. The valid range is from 1 to 9999.
For example, the following command specify that in addition to Warnings 101 through 121,
Warnings 500 through 600 will generate a coredump: admin> read debug { 1 1 1}
DEBUG/{ shelf-1 slot-1 1 } read admin> set min-warning-core-dump = 500 admin> set max-warning-core-dump = 600 admin> write
DEBUG/{ shelf-1 slot-1 1 } written
Changes to the Debug profile are effective immediately.
APX 8000/MAX TNT/DSLTNT Administration Guide 4-55
Creating User Profiles
5
User profiles are for TAOS unit system administration. Do not confuse them with Connection profiles. User profiles are used by administrators who need access to the TAOS unit’s command line interface to monitor or configure the unit. Connection profiles contain authentication and configuration information for a remote device or user and allow the remote user to connect to the TAOS unit for WAN or LAN access.
You can create any number of User profiles and fine-tune the privileges they allow. In addition to authentication and permission information, User profiles also contain parameters that affect how the user’s environment appears at login.
The TAOS unit ships with two predefined User profiles, named Admin and Default. The
Admin account is the super-user, with full read-write permissions. Default is set to the other extreme. It authorizes the minimal use of commands.
Many sites choose to create some administrative accounts in a read-only mode, to allow those users to check status windows, read log buffers, and execute diagnostic commands. You need at least one administrative account in read-write mode, but you may choose to create several such accounts.
APX 8000/MAX TNT/DSLTNT Administration Guide 5-1
Creating User Profiles
Understanding the User profile parameters
Understanding the User profile parameters
Table 5-1 describes common tasks you might have to perform to configure a User profile. The
table includes a brief description of each task and lists the parameters you will use.
Table 5-1. Overview of User profile tasks
Task
Setting the name and password
Activating the profile
Description of task Associated parameters
When you create a new User profile with the New command, the system creates a default instance of the profile and reads it into the edit buffer. The name and password you assign to the profile represent a user or host name and a password used to authenticate that user at login.
Name
Password
The User profile is activated when you first create it. If you set Active-Enabled to No, the profile is not available for use.
Active-Enabled
Assigning permissions
Logging the user out when idle
Permissions control which actions the user who logs in with this profile can perform on the TAOS unit.
Allow-Termserv
Allow-System
Allow-Diagnostic
Allow-Update
Allow-Password
Allow-Code
With the Idle-Timeout setting, you can specify the number of seconds a Telnet session can remain logged in with no keyboard activity.
Idle-Timeout
Setting the command-line prompt
Specifying which status windows are displayed at login
Defining which log messages will be displayed
The default command-line prompt is
TNT>
. If you set the prompt to an asterisk, the TAOS unit uses the name parameter as the prompt. For example, for the admin
User profile, the prompt would be admin>
.
Prompt
You can display status windows by default at login, and you can specify what information should be displayed initially in the top, bottom, and left windows.
Default-Status
Left-Status
Top-Status
Bottom-Status
You can specify that log messages should be displayed immediately in the interface, instead of written to a log.
You can also specify at which level the immediate display should begin. The lowest level is none , indicating that no messages should be displayed in the command-line interface. The highest level is debug .
Log-Message-Level
5-2 APX 8000/MAX TNT/DSLTNT Administration Guide
Creating User Profiles
Understanding command permissions
Understanding command permissions
Permissions control which actions the user who logs in with a particular profile can perform on the TAOS unit. Each permission enables the use of a command class. When you use the Help command to display available commands, the left column shows command names, and the right column shows the command class. For example: admin> ?
? ( user ) arptable ( system ) auth ( user ) cadslLines ( system ) callroute ( diagnostic ) cgCtrl ( system ) clear ( user ) clock-source ( diagnostic ) clr-history ( system ) connection ( system ) dadslLines ( system ) date ( update ) debug ( diagnostic ) delete ( update ) device ( diagnostic ) dir ( system ) dircode ( system ) dnstab ( system ) ds3AtmLines ( system ) ether-display ( diagnostic ) fatal-history ( system )
Typically, read-write accounts enable the System command class. They might also enable the
Update and Code command classes. Read-only accounts might be limited to the Diagnostic
command class. Table 5-2 shows the commands associated with each permission:
Table 5-2. Permissions and associated commands
Permission
N/A
(always enabled)
Command class
User
Commands in this class
?
Auth
Clear
Help
Quit
Whoami
APX 8000/MAX TNT/DSLTNT Administration Guide 5-3
Creating User Profiles
Understanding command permissions
Table 5-2. Permissions and associated commands (continued)
Permission Command class
Allow-System System ARPtable
BRIChannels
Clr-History
Connection
Dir
Dircode
DNStab
Fatal-History
Get
HDLC
IGMP
IPcache
IP-Pools
IProute
Line
List
Log
Modem
Allow-Diagnostic Diagnostic Callroute
Clock-Source
Debug
Device
DS3ATMlines
Ether-Display
If-Admin
NSlookup
Allow-Update Update Date
Delete
Load
Nvram
Allow-Code Code
Allow-Termserv Termserv. This permission enables the user to invoke the Terminal-Server command and use the terminal-server interface.
Format
Terminal-Server
Commands in this class
Netstat
New
OSPF
Power
Quiesce
Read
Refresh
Screen
Set
Show
Status
SWANlines
T1channels
UDS3lines
Userstat
Version
View
OAMLoop
Open
Ping
Rlogin
Slot
Telnet
Traceroute
Uptime
Reset
Save
Write
Fsck
5-4 APX 8000/MAX TNT/DSLTNT Administration Guide
Creating User Profiles
Sample User profiles
Table 5-2. Permissions and associated commands (continued)
Permission Command class
Allow-Password N/A
Commands in this class
The Allow-Password permission enables the user to view passwords. If set to No, the user sees a row of asterisks instead of the actual configured password. If the administrator that backs up system configurations does not have the Allow-Password permission set to Yes, passwords are not saved as part of the configuration.
Sample User profiles
If you have administrative privileges, you can create any number of User profiles that grant other administrators various degrees of access to the system.
When you create a new profile by specifying its index on the command line, the Default profile is used as the template. In the following is an example, an administrator creates a read-write administrative login named Bill, which has access to System, Diagnostic, and Update command classes: admin> new user admin
USER/admin read admin> set name = bill admin> set password = my-password admin> set allow-password = yes admin> set allow-code = no admin> write
USER/bill written
Following is an example of creating a User profile named Test, which is based on the Admin profile but restricts some permissions and has a different password: admin> new user admin
USER/admin read admin> set name = test admin> set password = test-pw admin> set allow-termserv = no admin> set allow-update = no admin> set allow-code = no admin> write
USER/admin written
In the following example, an administrator creates a profile that enables the user to use the terminal-server commands but not to perform any other actions:
APX 8000/MAX TNT/DSLTNT Administration Guide 5-5
Creating User Profiles
Customizing the environment for a User profile
admin> new user
USER/default read admin> set name = techpubs admin> set password = december admin> set allow-termserv= yes admin> set prompt = * admin> set log-display-level = none admin> write
USER/techpubs written
To log in by means of the new profile: admin> auth techpubs
Password: december
Customizing the environment for a User profile
In addition to authentication and permission information, User profiles also contain parameters that affect how the user’s environment appears at login. You can customize the following areas:
• The system prompt
• Whether the status window is displayed by default
• Information contained in the status window
• The level of log messages displayed
Setting the system prompt
The default command-line prompt is
TNT>
. You configure the prompt with the Prompt parameter. An asterisk in this setting causes the TAOS unit to substitute the value of the profile’s name parameter upon successful login. For example, for the Admin profile, the prompt would be as follows: admin>
Specifying status window information
The TAOS unit generates a continuous stream of statistics about its activities. You can specify in a User profile whether these statistics should always be displayed when a user logs in using that profile, what the areas of the window should display by default, and the size of the status windows. Opening the status window requires an 80-column by 24-row VT100 window.
The contents of the status window are determined by the following parameters in a User profile
(show with their default values):
• Left-Status = Connection-List
• Top-Status = General-Info
• Bottom-Status = Log-Window
5-6 APX 8000/MAX TNT/DSLTNT Administration Guide
Creating User Profiles
Customizing the environment for a User profile
The size of the status window are determined by the following parameters in a User profile
(shown with their default values)
• Screen-Length = 24
• Status-Length = 18
See the APX 8000/MAX TNT/DSLTNT Reference for details of using these parameters.
Figure 5-1 shows the default contents for each area of the status window:
Figure 5-1. Information in the status window
Left: Connection Top: General
2 Connections
001 tomw PPP 1/7/14 19200
002 timl MP 1/7/3 56000
Status
Serial number: 6201732 Version: X.0.0
Rx Pkt: 11185897
Tx Pkt: 42460
Col: 129
04/27/2000 12:20:15 Up: 3 days, 21:47:32
M: 48 L: info Src: shelf-1/controller
48 out of 48 modems passed POST
Issued: 16:48:02, 04/27/2000
Bottom: Log
Following is an example of configuring the User profile to display the status window upon login, and to show line information in the bottom area of the window. It also configures a larger terminal emulator window and status screens: admin> read user test
USER/test read admin> set default-status = yes admin> set bottom-status = line-status admin> set screen-length = 36 admin> set status-length = 30 admin> write
USER/test written
Note that Status-Length must be at least 6 lines smaller than Screen-Length.
APX 8000/MAX TNT/DSLTNT Administration Guide 5-7
Creating User Profiles
Customizing the environment for a User profile
Setting log levels for each login
You can configure the User profile to display a certain level of log messages immediately in the interface, in addition to writing them to a log file. Following is an example that causes critical, alert, and emergency messages to be displayed in the interface, interrupting whatever work might be going on at the prompt: admin> read user test
USER/test read admin> set log-display-level = critical admin> write
USER/test written
Critical messages indicate that an interface has gone down or a security condition has been noted. Alert messages indicate that something undesirable has happened but probably will not prevent normal operation of the system. Emergency messages indicate that something undesirable has happened and will probably prevent normal operation.
Other levels include Error messages (an error condition has occurred), Warning messages
(something out of the ordinary has occurred, such as a login failure), Notice (events in normal operation, such as a link going up or down), Info (changes that are not normally of interest),
Debug (messages related to debugging configurations), and None (no messages are displayed).
Logging in as a different user
To login with a different User profile, use the Auth command, as in the following example: admin> auth test
Password:@3wPZHd2
You must supply the password configured in the specified profile to be logged in as the user.
Logging in as a different user can be helpful for verifying that the User profile permissions are correct.
Specifying a timeout for logins
You can specify a timeout period after which idle sessions on the TAOS unit disconnect. The default is 60 seconds. To configure an idle timeout, proceed as in the following example:
1
Read the System profile: admin> read system
2
Specify an idle time period: admin> set idle-logout=120
3
Write the profile: admin> write
SYSTEM written
5-8 APX 8000/MAX TNT/DSLTNT Administration Guide
Creating User Profiles
Creating and managing remote user profile filters
Finding the current user
To find out which User profile you are currently using, enter the Whoami command. For example: admin> whoami admin
Creating and managing remote user profile filters
You can create RADIUS pseudo-user profiles that define data filters, and then apply the filters to multiple local Connection or RADIUS profiles by referring to the pseudo-user profile name.
When the TAOS receives a Filter-ID in an Access-Accept packet from RADIUS, it searches for a matching local filter. If it does not find one, the TAOS unit requests the filter from the
RADIUS server. You can specify how the system should behave if the filter referred to in a profile is not found. The system can either establish the session and log a message about the missing filter, or terminate the call if a filter is not found.
Externally defined filters are cached locally for a configurable interval. The FiltCache command displays statistics about each cached RADIUS filter profile, and enables you to flush profiles from the cache.
Current limitations
In this release, the remote filter implementation is subject to the following limitations:
• Filters applied to dialout calls are not supported in this release.
• Call filters, route filters, and TOS filters are not supported in this release. Only data filters are currently supported.
Overview of local profile settings
Following are the local parameters related to dynamic remote filters:
[in ANSWER-DEFAULTS:session-info] filter-required = no
[in CONNECTION:session-options] filter-required = no data-filter = ""
[in IP-GLOBAL] default-filter-cache-time = 1440
APX 8000/MAX TNT/DSLTNT Administration Guide 5-9
Creating User Profiles
Creating and managing remote user profile filters
Parameter
Filter-Required
Data-Filter
Default-Filter-Cache-
Time
Specifies
Whether access to the filter is required for the session. With the default value of No, the system establishes the session even if the specified filter is not found. If the parameter is set to yes
, the system disconnects the call if the filter is not found. This setting does not apply if the profile does not refer to a filter by name.
The Answer-Defaults setting is used for RADIUS user profiles that apply a filter and do not explicitly specify a value for
Ascend-Filter-Required (50).
Name of a Filter profile associated with the connection. The name can be of a local profile or a filter pseudo-user profile in RADIUS.
However, if a local Connection profile does not use authentication, it cannot specify a RADIUS filter profile.
Number of minutes to cache RADIUS filter profiles that do not include a value for Ascend-Cache-Time (57). The default is
1440
(24 hours). Once the cache timer expires, cached profiles are deleted from system memory. The next time a remote filter is needed, the system retrieves the profile from RADIUS and stores it in cache again. Keeping a profile in cache increases the performance of establishing sessions that use the filter, at the cost of some system memory. If this parameter is set to
0
(zero), the default timer is disabled so that only RADIUS profiles that specify a cache time are cached.
Overview of RADIUS user profile settings
RADIUS user profile support for filter profiles is provided by the following vendor-specific attributes (VSAs):
RADIUS attribute
Filter-ID (11)
Ascend-Filter-Required
(50)
Value
Name of a local or remote filter profile associated with the connection.
Whether access to the filter is required for the session. With the default value of Required-No (0), the system establishes the session even if the specified filter is not found. If the attribute is set to Required-Yes (1), the system disconnects the call if the filter is not found. This setting does not apply if the profile does not refer to a filter by name. If this attribute is not specified, the
Answer-Defaults setting is used to determine system behavior when the specified filter is not found.
5-10 APX 8000/MAX TNT/DSLTNT Administration Guide
Creating User Profiles
Creating and managing remote user profile filters
Overview of RADIUS pseudo-user profile settings
A filter profile is a pseudo-user profile in which the first two lines have the following format:
profile-name Password = "ascend" Service-Type = Outbound
The profile-name value is any name you assign to the profile. Duplicate filter names are not allowed. If a local Filter profile is already stored, the TAOS does not retrieve a filter profile of the same name from the RADIUS server. Filter profile definitions can include the following attribute-value pairs:
RADIUS attribute Value
Ascend-Data-Filter (242) An abinary-format filter specification using one of the following formats:
"generic dir action offset mask value compare
[more]"
"ip dir action [ dstip n.n.n.n/nn ] [ srcip
n.n.n.n/nn ][ proto ] [ destport cmp value ] [ srcport cmp value ] [est]]"
Ascend-Cache-Refresh
(56)
Whether the timer for cached routes in this profile is reset each time a new session becomes active that refers to the pseudo-user profile. Refresh-No (0) does not reset the timer. Refresh-Yes (1) resets the cache timer when a session referring to the profile becomes active.
Ascend-Cache-Time (57) Number of minutes to cache the profile. Once the cache timer expires for a RADIUS profile, the profile is deleted from system memory. The next time it is needed, the system retrieves it from
RADIUS and stores it in cache again. Keeping a profile in cache increases the performance of route lookups, at the cost of some system memory. The minimum possible cache time is 0 minutes, which causes the system to retrieve the profile for every route lookup in the table. This setting is usually not desirable. If this attribute is not specified, the IP-Global setting is used.
To use these attributes, the RADIUS server must support vendor-specific attributes (VSAs) and the TAOS must be configured in VSA compatibility mode. Following are the relevant settings:
[in EXTERNAL-AUTH] auth-type = radius
[in EXTERNAL-AUTH:rad-auth-client] auth-radius-compat = vendor-specific
For details about these settings, see the APX 8000/MAX TNT/DSLTNT Reference. For details about defining data filters in RADIUS, see the APX 8000/MAX TNT/DSLTNT WAN, Routing,
and Tunneling Configuration Guide.
APX 8000/MAX TNT/DSLTNT Administration Guide 5-11
Creating User Profiles
Creating and managing remote user profile filters
Examples of configuring a filter profile in RADIUS
Following is a sample RADIUS filter profile: filter-c Password = "ascend", Service-Type = Outbound
Ascend-Cache-Time = 20,
Ascend-Cache-Refresh = Refresh-Yes,
Ascend-Data-Filter = "ip out forward tcp dstip 10.1.1.3/16",
Ascend-Data-Filter = "ip out drop"
The cache timer has been set to 20 minutes, and the timer is reset each time the filter is applied to a session.
The following commands configure a default cache time for RADIUS filter profiles: admin> read ip-global
IP-GLOBAL read admin> set default-filter-cache-time = 180 admin> write
IP-GLOBAL written
Following is a sample RADIUS filter profile that makes use of the default because a value for
Ascend-Cache-Time (57) is not explicitly specified: filter-e Password = "ascend", Service-Type = Outbound
Ascend-Data-Filter = "ip out forward tcp dstip 10.2.2.2/28",
Ascend-Data-Filter = "ip out drop"
Examples of applying remote filters
The following commands modify a Connection profile so that the session uses a remote filter and the system disconnects the call if the filter is not found: admin> read connection p50-v2
CONNECTION/p50-v2 read admin> set session-options data-filter = filter-c admin> set session-options filter-required = yes admin> write
CONNECTION/p50-v2 written
Following is a sample RADIUS profile that applies the same filter profile with the same requirements. This profile also specifies how the filters must be cached for this connection: p50-v2 Password = "my-password", Service-Type = Framed
Framed-Protocol = PPP,
Framed-IP-Address = 10.1.1.1,
Framed-IP-Netmask = 255.0.0.0,
Filter-ID = "filter-c",
Ascend-Filter-Required = Required-Yes
The following commands configure the system to reject incoming calls when the RADIUS user profile specifies a filter that is not found, and the user profile does not explicitly say what to do if the filter is not found: admin> read answer-defaults
ANSWER-DEFAULTS read
5-12 APX 8000/MAX TNT/DSLTNT Administration Guide
Creating User Profiles
Creating and managing remote user profile filters
admin> set session-info filter-required = yes admin> write
ANSWER-DEFAULTS written
Following is a sample RADIUS profile that makes use of the default because a value for
Ascend-Filter-Required (55) is not explicitly specified: p50-v2 Password = "my-password", Service-Type = Framed
Framed-Protocol = PPP,
Framed-IP-Address = 10.1.1.1,
Framed-IP-Netmask = 255.0.0.0,
Filter-ID = "filter-c"
Managing remote filters
Filters defined in RADIUS pseudo-user profiles are accessible in the command-line interface as if they were local Filter profiles. For example, in the following listing, the profiles named filter-a
and filter-b
are local Filter profiles, and the profile named filter-c
is a filter profile obtained from RADIUS: admin> dir filter
464 01/04/2000 19:01:49 filter-a
470 01/04/2000 19:10:57 filter-b
3901 01/04/2000 20:01:50 filter-c
You can read and list the contents of the remote filters in the usual way, as if they were local profiles. For example: admin> read filter filter-c
FILTER/filter-c read (read-only) admin> list
[in FILTER/filter-c] filter-name* = filter-c input-filters = [ { no no generic-filter { 0 0 no no + output-filters = [ { yes no ip-filter { 0 0 no no +
Note:
You cannot change RADIUS filter specifications from the command-line interface.
You can delete RADIUS filter profiles by using the delete
command. For example: admin> delete filter filter-c
Delete profile FILTER/filter-c? [y/n] y
FILTER/filter-c deleted
APX 8000/MAX TNT/DSLTNT Administration Guide 5-13
Creating User Profiles
Default-Filter-Cache-Time
Parameter reference entries
Default-Filter-Cache-Time
Description: Specifies the default time (in minutes) during which the RADIUS filter profile remains locally cached on the TAOS.
Usage: Specify an integer. The default is
1440
minutes (24 hours). If you specify
0
(zero), the system does not cache the profile.
Example:
set default-filter-cache-time = 720
Location: IP-Global
See Also: Filter-Required
Filter-Required
Description: Specifies whether the TAOS establishes a call if the filter profile applied in the caller’s Connection profile cannot be found locally or in RADIUS.
Usage: Specify yes
or no
. The default is no
.
• yes specifies that the TAOS does not establish a call if the filter profile applied in the caller’s Connection profile cannot be found locally or in RADIUS.
• no specifies that the TAOS establishes a call if the filter profile applied in the caller’s
Connection profile cannot be found locally or in RADIUS.
Example:
set filter-required = yes
Dependencies: Consider the following:
• If the call needs to be brought down, the cause code 425 results. If the call is allowed to come up, the system logs a notice-level message that the filter cannot be found.
• If the Ascend-Filter-Required attribute is missing in the RADIUS user profile, the TAOS uses the Filter-Required value in the Answer-Defaults profile.
Location: Answer-Defaults > Session-Info, Connection > Session-Options
5-14 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
6
The TAOS unit supports SNMP (Simple Network Management Protocol) on a TCP/IP network. An SNMP management station that uses supported MIBs can query the TAOS unit, set some parameters, sound alarms when certain conditions appear in the TAOS unit, and so forth. The TAOS unit has its own SNMP password security (community strings), which you should set up to protect the TAOS unit from being reconfigured from an SNMP station.
The TAOS unit supports profiles that control which classes of events will generate traps to be sent to an SNMP manager, which SNMP managers may access the unit, and community strings to protect that access. This chapter describes SNMP support on the TAOS unit and also shows you how to set up the unit to work with SNMP.
SNMP support
This section describes the SNMP supported on the TAOS unit.
Standard MIBS
This section describes the standard MIBs supported on the TAOS unit.
RFC 1213 (MIB-II)
Enables you to monitor and configure basic components of the TAOS unit’s system, interfaces, and protocols. Note that the interface table in MIB-II is superseded by RFC 2233 (Interface
MIB).
RFC 1253 (OSPF MIB)
Enables you to monitor and configure OSPF version 2.
APX 8000/MAX TNT/DSLTNT Administration Guide 6-1
SNMP Administration
SNMP support
RFC 1315 (Frame Relay MIB)
The Frame Relay MIB specifies SNMP MIB variables for Frame Relay DTEs. The TAOS unit’s HDLC cards support this MIB.
RFC 1317 (RS232 MIB)
Enables you to monitor and configure asynchronous or synchronous serial links with
RS-232-like control signals.
RFC 1398 (Ethernet MIB)
Enables you to monitor the TAOS unit’s Ethernet interfaces.
RFC 1406 (DS1 MIB)
Enables you to query the state and configuration of T1 or E1 lines. The TAOS unit supports all tables in this MIB except the dsx1FracTable
.
In addition, TAOS unit’s also support loopback modes using the Get and Set requests on the dsx1LoopBackConfig
object of the DS1 MIB (RFC 1406).The dsx1NoLoop
and dsx1LineLoop
loopback modes are supported on both T1 and E1 lines. The dsx1PayloadLoop
loopback mode is not supported.
RFC 1407 (DS3 MIB)
Enables you to query the state and configuration of T3 or E3 lines.
RFC 1695 (ATM MIB)
Enables you to manage the ATM interface on the TAOS unit’s DS3-ATM card. The TAOS unit supports the following groups in the ATM MIB related to network endpoints:
• (1) ATM Interface configuration group
• (2) ATM Interface DS3 PLCP group
• (3) ATM Interface TC Sublayer group
• (5) ATM Interface VCL configuration group
• (8) ATM Interface AAL5 VCC performance statistics group
Currently it is not possible to define new connections solely by using SNMP management, so many of the read-write and read-create parameters were changed to read-only.
RFC 1696 (Modem MIB)
The Modem MIB defines managed objects for modems. The TAOS unit supports all objects in the Modem MIB.
The Modem MIB defines an mdmIndex
object whose value is used as an index into the tables defined in the MIB, with each modem in a managed system assigned a unique index value.
This object is supported in the TAOS unit as a read-only Modem-Table-Index parameter in the
Admin-State profile.
6-2 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
SNMP support
The value of this parameter is allocated by the system when it first detects the presence of a modem card.
The fact that the TAOS unit supports hot-swapable cards requires a relaxation of the MIB definition of the mdmIndex
object in the same manner that RFC 1573 relaxes the ifIndex definition. The MIB definition of mdmIndex
specifies that
• the index value must be in the range of 1 to mdmNumber, and
• the value must remain constant from one reinitialization of the network management agent to the next.
A modem card may be added to or removed from the TAOS unit without reinitializing the
SNMP agent, which affects both of these definitions. For example, if a modem card is inserted into slot 1 of a new TAOS unit’s system, its 48 modems are allocated the index values 1 through 48. If another modem card is inserted into slot 3, its modems are allocated the index values 49 through 96. If the TAOS unit is rebooted, these values remain constant. If the modem card in slot 1 is removed and the TAOS unit is rebooted again, the index values for the modem card in slot 3 still remain constant with the range 49 through 96, even though the value of mdmNumber is now 48.
RFC 1850 (OSPF Traps, Version 2 MIB)
TAOS units support OSPF traps as defined in RFC 1850, OSPF Version 2 Management
Information Base. For an OSPF trap to be generated when the trap condition occurs, OSPF traps must be enabled, either in the Trap profile or by setting the corresponding bit in the new
MIB object, ospfSetTrap
, defined in RFC 1850. In addition, the individual trap that represents the trap condition must be enabled.
RFC 2233 (Interface MIB)
The TAOS unit supports the Interface MIB based on RFC 2233, which supersedes the SNMP
MIB-II interface table defined in RFC1213. The interface table contains only the system’s physical interfaces and nailed (permanent) interfaces.
The index value of an interface does not change following a system reset, and if an entry is removed from the interface table dynamically, its index value is not reused until the management station has been reinitialized. The interface table does not contain virtual circuit interfaces, such as a Frame Relay datalink configured on a channelized DS1 interface.
Table 6-1 describes the TAOS unit’s support for RFC 2233.
Table 6-1. TAOS unit support for RFC 2233
RFC 2233 Table
ifTable
Comment
The ifTable from MIB-II (RFC 1213) and is fully supported on the TAOS unit.
APX 8000/MAX TNT/DSLTNT Administration Guide 6-3
SNMP Administration
SNMP support
Table 6-1. TAOS unit support for RFC 2233 (continued)
RFC 2233 Table Comment
ifXTable
The TAOS unit supports this table with the following exceptions:
• The
OwnerString
object is not supported.
• The
InterfaceIndexOrZero
object is not supported.
• The 64-bit HighCounter objects are not supported.
• The ifPromiscuousMode
object is read-only.
Not supported on the TAOS unit.
ifStackTable ifRcvAddressTable Not supported on the TAOS unit.
ifTestTable Not supported on the TAOS unit.
RFC 2515 (ATM MIB)
Enables you to manage the ATM interface on the TAOS unit’s DS3-ATM card. The TAOS unit supports Get operations on the following tables of the ATM MIB described in RFC 2515,
Definitions of Managed Objects for ATM Management:
• ATM Interface configuration table
• ATM Interface DS-3 Physical Layer Convergence Protocol (PLCP) table
• ATM Interface transmission convergence (TC) sublayer table
• ATM Interface virtual channel link (VCL) configuration table
• ATM Interface ATM Adaptation Layer 5 (AAL5) virtual channel connection (VCC) performance statistics table
Set operations are not yet supported. In addition, the following SNMPv2-related changes were made to rfc2514.mib
:
• The definition of atmMIB and atmMIBObjects were moved here from rfc2515.mib
.
• All the definitions were modified to SNMPv1 Structure of Management Information
(SMI).
• The SNMPv1 entries atmNoTrafficDescriptor
, atmClpNoTaggingNoScr
, and atmClpTaggingNoScr
are deprecated.
The following SNMPv2-related changes were made to rfc2515.mib
:
• The definitions of atmMIB
and atmMIBObjects
were moved to rfc2514.mib
.
• All MIB fields with Current Status were changed to Mandatory.
• MAX-Access syntax was changed to Access for all the fields.
• Fields with read-create access were changed to read-write.
• Set functions are not supported on the following parameters, so they have been changed from read-write to read-only:
6-4 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
SNMP support
– atmInterfaceConfEntry
parameters
– atmVclReceiveTrafficDescrIndex
, atmVclTransmitTrafficDescrIndex and atmVclAdminStatus in atmVclTable
– atmVccAalType
, atmVccAal5CpcsTransmitSduSize
, atmVccAal5CpcsReceiveSduSize
, atmVccAal5EncapsType
, atmVclRowStatus
, atmVclCastType
and atmVclConnKind
in atmVclTable
• Read-write permissions were changed to read-only permission in the following tables:
– atmTrafficDescrParamTable
– atmVplTable
• The atmVpCrossConnectTable
and atmVcCrossConnectTable
tables are not supported.
RFC 2574 (SNMPv3 User-Based Security Model (USM) MIB)
TAOS units support security enhancements based on the SNMPv3 user-based security model
(USM) described in RFC 2574. In this release, SNMPv3 encryption is not supported. The
Priv-Protocol parameter is set to no-priv
and its value cannot be modified.
In addition to the security enhancement features, SNMPv3 supports the
GetBulkRequest
PDU. Its purpose is to minimize the number of protocol exchanges required to retrieve a large amount of management information. The
GetBulkRequest
PDU allows an SNMPv3 manager to request a response that is as large as possible given the constraints on message size.
To use SNMPv3, the network-management license must be enabled in the system. The following commands verify that the network management license has been enabled on the system: admin> get base network-management
[in BASE:network-management-enabled] network-management-enabled = yes
Overview of SNMPv3 settings
Following are the relevant parameters, shown with their default settings:
[in SNMP] snmp-message-type = v1-and-v3 security-level = none
[in SNMPv3-USM-USER/""] name* = "" password = "" active-enabled = no read-write-access = no auth-protocol = md5-auth priv-protocol = no-priv
APX 8000/MAX TNT/DSLTNT Administration Guide 6-5
SNMP Administration
SNMP support
Parameter
SNMP-Message-Type
Security-Level
Name
Password
Active-Enabled
Read-Write-Access
Auth-Protocol
Priv-Protocol
Specifies
SNMP protocol used by the SNMP agent in the unit. If the parameter is set to v1-and-v3
(the default), the SNMP agent uses both SNMPv1 and SNMPv3 protocols. With the v1-only setting, the SNMP agent uses only the SNMPv1 protocol and will discard SNMPv3 messages. If the parameter is set to v3-only
, the SNMP agent uses only the SNMPv3 protocol.
Security level of the SNMP agent when SNMPv3 is in use. With the default none
setting, no security level checking is required for incoming message. If the parameter is set to auth-nopriv
, the
SNMPv3-USM-User profile for the user sending a message must have the Auth-Protocol set to md5-auth
or sha-auth
.
Otherwise, the SNMP agent returns a REPORT message to the manager indicating an unsupported security level.
This parameter does not apply to SNMPv1 messages.
Username. Messages sent to or from the SNMP engine on behalf of this name will use the security parameters specified in this profile. The value can contain up to 23 characters and can include special characters by using the \xNN format with the ASCII code for the character. For example, the value test\x20\x21 represents the string “ test !
”.
A password, up to 20 characters in length, which maps to a 16 or
20 octet key, in compliance with RFC 2574. Passwords are case sensitive and can include special characters by using the \xNN format with the ASCII code for the character. For example, the value test\x20\x21
represents the string “ test !
” This setting is required if Auth-Protocol is set to a value other than no-auth
.
Enable/disable SNMPv3 user-based security model (USM) features for this user. The default value is no .
Enable/disable read-write access to the unit’s MIBs for this user.
With the default no value, the user has read access only, which enables viewing but not modification of the MIBs.
Enable/disable authentication of messages sent on behalf of this user to or from the SNMP engine, and if enabled, the type of authentication protocol to be used. If this parameter is set to a value other than no-auth
, the Password parameter must specify the password to be used. Following are the valid values: no-auth disables authentication for this user.
md5-auth (the default value) enables authentication and specifies that the MD5 protocol must be used.
sha-auth
enables authentication and specifies that SHA protocol must be used.
Enable/disable encryption of messages sent on behalf of this user to or from the SNMP engine, and if enabled, the type of privacy protocol to be used. Not currently supported.
6-6 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
SNMP-Message-Type
Example of configuring SNMPv3 USM
To configure the USM features for a user, you must specify a name for the profile and set the
Active-Enabled parameter to yes . You must also specify a password if the Auth-Protocol parameter is set to anything but no-auth .
The following commands specify that MD5 authentication must be used for messages sent on behalf of a user named testv3
to or from the SNMP engine. The user is assigned read-write access to the unit’s MIBs.
admin> new snmpv3-usm-user testv3
SNMPv3-USM-USER/testv3 read admin> set password = 1rma\x21w admin> set active-enabled = yes admin> set read-write-access = yes admin> write
SNMPv3-USM-USER/testv3 written admin> list
[in SNMPv3-USM-USER/testv3] name* = testv3 password = ****** active-enabled = yes read-write-access = yes auth-protocol = md5-auth priv-protocol = no-priv
Example of restricting the agent to SNMPv3
The following commands cause the SNMP agent to use only SNMPv3 and to check a user’s security level before allowing access: admin> read snmp
SNMP read admin> set snmp-message-type = v3-only admin> set security-level = auth-nopriv admin> write
SNMP written
Parameter reference entries
SNMP-Message-Type
Description: SNMP protocol used by the SNMP agent in the unit.
Usage: Specify one of the following values:
• v1-and-v3
(the default) causes the SNMP agent to use both SNMPv1 and SNMPv3 protocols.
• v1-only
causes the SNMP agent to use only the SNMPv1 protocol and discard any other type of messages.
• v3-only
causes the SNMP agent to use only the SNMPv3 protocol and discard other types of messages.
APX 8000/MAX TNT/DSLTNT Administration Guide 6-7
SNMP Administration
Security-Level
Example:
set snmp-message-type = v3-only
Location: SNMP profile
See Also: Security-Level
Security-Level
Description: Security level of the SNMP agent when SNMPv3 is in use.
Usage: Specify one of the following values:
• none
(the default) means that no security level checking is required for incoming messages.
• auth-nopriv
means that the SNMPv3-USM-User profile for the user sending a message must have the Auth-Protocol set to a value other than no-auth.
Example:
set security-level = auth-nopriv
Dependencies: This parameter does not apply to SNMPv1 messages.
Location: SNMP profile
See Also: SNMP-Message-Type
Active-Enabled
Description: Activates a SNMPv3 USM user profile and makes it available for use.
Usage: Specify Yes or No. No is the default.
Example:
set active-enabled = yes
Location: SNMPv3-USM-User profile
See Also: Auth-Protocol, Name, Password, Priv-Protocol, Read-Write-Access
Auth-Protocol
Description: Specifies whether or not the TAOS unit can authenticate SNMPv3 messages sent to and from the SNMP engine on behalf of the SNMPv3 USM user. Also, specifies the type of authentication protocol the unit uses.
Usage: Specify one of the following settings:
• no-auth —No authentication.
• md5-auth (the default)—The TAOS unit uses the MD5 protocol to authenticate incoming and outgoing messages.
• sha-auth
—The TAOS unit uses the SHA protocol to authenticate incoming and outgoing messages.
Example:
set auth-protocol = md5-auth
Location: SNMPv3-USM-User profile
See Also: Active-Enabled, Name, Password, Priv-Protocol, Read-Write-Access
6-8 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
Name
Name
Description: Specifies the user for whom the TAOS unit exchanges an SNMPv3 USM message.
Usage: Specify a name that contains up to 23 characters. The name can include special characters by using the \xNN format with the ASCII code for the character. For example, the value test\x20\x21 represents the string “test !”.
Example:
set name = testv3
Location: SNMPv3-USM-User profile
See Also: Active-Enabled, Auth-Protocol, Password, Priv-Protocol, Read-Write-Access
Password
Description: Specifies the user’s password, which maps to a 16 or 20 octet key, in compliance with RFC 2574. Passwords are case sensitive.
Usage: Specify up to 20 characters. The password can include special characters by using the
\xNN format with the ASCII code for the character. For example, the value test\x20\x21 represents the string “test !”.
Example:
set password = 1rma\x21w
Dependencies: In the SNMPv3-USM-User profile, you must specify a password if the
Auth-Protocol parameter is set to a value other than no-auth
.
Location: SNMPv3-USM-User profile
See Also: Active-Enabled, Auth-Protocol, Name, Priv-Protocol, Read-Write-Access
Priv-Protocol
Description: Specifies whether or not messages that are sent to or from the SNMP engine can be protected by encryption and the type of privacy protocol to be used.
Usage: The default is no-priv
. In this release, you cannot change the default setting.
Dependencies: The TAOS unit’s SNMPv3 engine does not support encryption/decryption.
Location: SNMPv3-USM-User profile
See Also: Active-Enabled, Auth-Protocol, Name, Password, Read-Write-Access
Read-Write-Access
Description: Specifies whether or not the TAOS unit grants the SNMPv3 USM user read and write access to the unit’s management information base (MIB) settings.
Usage: Specify Yes or No. No is the default. With the default No value, the user has read access only, which enables viewing but not modification of the MIBs.
Example:
set read-write-access = no
Location: SNMPv3-USM-User profile
APX 8000/MAX TNT/DSLTNT Administration Guide 6-9
SNMP Administration
Read-Write-Access
See Also: Active-Enabled, Auth-Protocol, Name, Password, Priv-Protocol
Ascend enterprise MIBS
The Enterprise MIB is registered with the IANA (Internet Assigned Numbers Authority) as: enterprises 529 with this value:
1.3.6.1.4.1.529
Ascend MIB (ascend.mib)
The Ascend MIB consists of the following groups:
• products (1)
• slots (2)
• hostTypes (3)
• advancedAgent (4)
• lanTypes (5)
• doGroup (6)
• hostStatus (7)
• console (8)
• systemStatusGroup (9)
• eventGroup (10)
• callStatusGroup (11)
• sessionStatusGroup (12)
• radiusGroup (13)
• mCastGroup (14)
• lanModemGroup (15)
• firewallGroup (16)
• wanDialoutPkt (17)
• powerSupply (18)
• multiShelf (19)
• miscGroup (20)
• asgGroup (21)
• flashGroup (22)
• configuration (23)
• atmpGroup (24)
• srvcMgmtGroup (26)
6-10 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
Read-Write-Access
Ascend Advanced Agent MIB (advanced.mib)
The TAOS unit supports the Ascend Advanced MIB, previously called the WAN MIB. The
Advanced MIB defines objects related to WAN lines, channels, and ports.
MIB variables for summarizing B channel states
The Advanced MIB includes wanLineChannelUsageTable(29)
, immediately following advancedAgent(4)
. The new table contains read-only integer variables that reflect the total count of B channels in any particular state for any given line usage. For example, you can use the table to retrieve the sum of all signaling channels (the number of connected calls) on all trunk lines, or to retrieve the sum of nailed, idle, or ringing channels, or the sum of connected DTPT channels on network (NT) lines.
The new table is indexed by the line usage and B channel state, as defined by the wanLineUsage and wanLineChannelState enumerations in advanced.mib. The MIB currently identifies nine possible line usages and 24 B channel states, yielding a total of 216 new variables that represent the sum of all B channels in a given state for a given line usage.
Ascend Answer Profile MIB (mibanswer.mib)
Part of the Ascend MIB Configuration group (group 23), this MIB corresponds to the
Answer-Defaults profile in the command line interface.
Ascend ATMP MIB (atmp.mib)
Enables you to configure and monitor Ascend Tunnel Management Protocol (ATMP) tunnels.
For a complete description of ATMP, see RFC 2107, K. Hamzeh, “Lucent’s Ascend Tunnel
Management Protocol - ATMP.”
Ascend Call MIB (call.mib)
Contains a table of entries for the status of each call in the system, including analog, digital, and Frame Relay-encapsulated calls. This MIB monitors the physical layer of the calls, including the slot and port. The Ascend Session MIB enables you to monitor the network layer of calls.
Variables added from event.mib to call.mib
A number of new entries have been added to the callStatus
and callActive
tables in the Ascend Call MIB, making more information about the call available to the SNMP user.
The callStatus
Table in the Ascend Call MIB includes the following new fields:
Field name
callStatusCalledPartyID callStatusCallingPartyID callStatusMultiLinkID
Reports
Called party number (if available).
Calling party number (if available). For outgoing calls, this field is set to null.
MP+ bundle ID for MP+ calls. For a non-MP+ call, this field is set to
0
(zero).
APX 8000/MAX TNT/DSLTNT Administration Guide 6-11
SNMP Administration
Read-Write-Access
The callActiveTable
in the Ascend Call MIB includes the following new fields:
Field name
callActiveCalledParyID callActiveCallingPartyID callActiveMultiLinkID
Reports
Called party number (if available).
Calling party number (if available). For outgoing calls, this field is set to null.
MP+ bundle ID for MP+ calls. For a non-MP+ call, this field is set to
0
(zero).
Ascend DS3 Profile MIB (mibds3net.mib)
Part of theAscend MIB Configuration group (group 23), this MIB corresponds to the T3 profile in the command line interface.
Ascend Event MIB (event.mib)
This read-only MIB enables you to monitor the TAOS unit’s events. Includes connect progress and disconnect codes for calls.
Idle Time variable in the active session table
In addition to displaying the idle time for an active session by using the userstat -o %t command, the same information is made available to SNMP management stations through the ssnActiveIdleTime
object in the sessionActiveTable
. The object uses Object ID sessionActiveEntry.8
. Itshows the time the session has been idle in 0.01-second increments). Following is the object definition: ssnActiveIdleTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "The time, current session has been idle.
For non-TNT and non-Max platforms 0 is always
reported."
::= { sessionActiveEntry 8 }
TCP-Clear login host IP address reported
The IP address of login hosts for TCP-Clear sessions is reported in the Simple Network
Management Protocol (SNMP) event Management Information Base (MIB), Syslog messages, and the output of the Userstat command.
SNMP event MIB changes
When a TCP-Clear connection is successfully established, the login host’s IP address is specified in the eventUserIPAddress
object in the SNMP callCleared
event. The definition of the eventUserIPAddress
object in the event MIB has been modified as follows: eventUserIPAddress OBJECT-TYPE
SYNTAX IpAddress
6-12 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
Read-Write-Access
ACCESS read-only
STATUS mandatory
DESCRIPTION "IP address of the remote user or login host.
Applicable only if ’eventType’ is serviceChanged(4)
nameChanged(5) or callCleared. Value of a TCP-Clear
login host IP address is returned once a TCP-Clear
connection was successfully connected earlier in
a serviceChanged event.
The value 0.0.0.0 is returned if address is unknown
or if not applicable."
::= { eventEntry 13 }
Syslog messages
When a TCP-Clear session is terminated, the login host’s IP address is displayed instead of the zero address (0.0.0.0) in the Syslog message. For example:
[3/7/2/0] STOP: ’johnfan’; cause 11.; progress 43.; host 10.1.1.1
[MBID 2] [johnfan]
Userstat command output
For an active TCP-Clear session, the login host’s IP address is displayed instead of the zero address (0.0.0.0) in the Userstat Address field. For example:
SessionID Line/Chan Slot:Item Tx/Rx Rate Svc Address Username
286993415 3.01.08/012 3:07:03/000 26400/26400 TCP 10.1.1.1 johnfan
<end user list> 1 active user(s)
Note:
If the TCP-Clear connection fails (if the login attempt has not been successfully established between the TAOS unit and any of the specified login hosts), the Userstat command shows the zero address in the Address field.
Ascend Firewall MIB (firewall.mib)
Enables you to dynamically configure Ascend Secure Access Firewalls that were created with
Secure Access Manager (SAM). With this MIB, you can create or disable the firewall’s dynamic rules.
Ascend Flash MIB (flash.mib)
Enables you to monitor the status of the TAOS unit’s flash cards, store or retrieve configuration files, or format the flash cards.
SNMP: Configuration of TFTP port for network management
The flashOperationTftpPort
object has been added to the Ascend Flash MIB to configure the TFTP port setting for environments in which a network management station is running more than one management application, with a TFTP server local to each application.
The flashOperationTftpPort
object is defined in the Flash MIB and used in the load-config
, save-config
, and tftp-load
Flash MIB operations. The object’s default setting is 69, which is the default port for TFTP operations. The object is defined as follows in the Flash MIB:
APX 8000/MAX TNT/DSLTNT Administration Guide 6-13
SNMP Administration
Read-Write-Access
flashOperationTftpPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object defines the port # to use on the remote system
when starting a TFTP operation using a flashOperationCommand. The
default port is 69/(tcp/udp) Trivial File Transfer."
::= { flashOperation 8 }
The new Flash MIB has the following structure:
|- 1 flashDevice flashGroup.1
| |- 1 flashDevices flashGroup.1.1
| \_ 2 flashDeviceTable flashGroup.1.2
| \_ 1 flashDeviceEntry flashGroup.1.2.1
| |- 1 flashDeviceSocket flashGroup.1.2.1.1
| |- 2 flashDeviceController flashGroup.1.2.1.2
| |- 3 flashDeviceControllerSocket flashGroup.1.2.1.3
| |- 4 flashDeviceSize flashGroup.1.2.1.4
| |- 5 flashDeviceUsed flashGroup.1.2.1.5
| |- 6 flashDeviceState flashGroup.1.2.1.6
| |- 7 flashDeviceMaster flashGroup.1.2.1.7
| |- 8 flashDeviceFormatStatus flashGroup.1.2.1.8
| +- 9 flashDeviceDescription flashGroup.1.2.1.9
|- 2 flashFileTable flashGroup.2
| \_ 1 flashFileEntry flashGroup.2.1
| |- 1 flashFileIndex flashGroup.2.1.1
| |- 3 flashFileSocket flashGroup.2.1.3
| |- 4 flashFileSize flashGroup.2.1.4
| |- 5 flashFileStatus flashGroup.2.1.5
| |- 6 flashFileName flashGroup.2.1.6
| |- 7 flashFileChecksum flashGroup.2.1.7
| |- 8 flashFileVersion flashGroup.2.1.8
| |- 9 flashFileAccess flashGroup.2.1.9
| +- 10 flashFileDateTimeStamp flashGroup.2.1.10
\_ 3 flashOperation flashGroup.3
|- 1 flashOperationStatus flashGroup.3.1
|- 2 flashOperationCommand flashGroup.3.2
|- 3 flashOperationHost flashGroup.3.3
|- 4 flashOperationDestFileName flashGroup.3.4
|- 5 flashOperationSrcFileName flashGroup.3.5
|- 7 flashOperationSocket flashGroup.3.7
|+- 8 flashOperationTftpPort flashGroup.3.8
Ascend Frame Relay Profile MIB (mibfrmrl.mib)
Part of the Ascend MIB Configuration group (group 23), this MIB corresponds to the
Frame-Relay profile in the command line interface.
Ascend Internet Profile MIB (mibinet.mib)
Part of the Ascend MIB Configuration group (group 23), this MIB corresponds to the
Connection profile in the command line interface.
6-14 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
Read-Write-Access
Ascend Lan Modem MIB (lmodem.mib)
Enables you to monitor the status of the TAOS unit’s digital modems, including the number available, number of bad or suspect modems, and usage statistics. It also allows you to disable individual modems.
Ascend Multicast MIB (mcast.mib)
This read-only MIB enables you to view the status of the multicast heartbeat monitor.
Ascend Multishelf MIB (ms.mib)
This MIB manages multishelf configuration, including whether the shelf is a master or a slave, its shelf number, and multishelf statistics.
Ascend Power Supply MIB (ps.mib)
This MIB manages the TAOS unit’s power supplies.
Ascend RADIUS MIB (radius.mib)
Enables you to view the status of Ascend RADIUS accounting and authentication servers, including client requests and the servers’ responses. You can also use this MIB to mark a
RADIUS server as the current server.
Ascend Resources MIB (resource.mib)
Enables you to report utilization and availability details about terminating access resources such as modems, HDLC channels, and MultiDSP devices.
For cards that support resourceUsageTable
and resourceTable
in resource.mib
, the system can report utilization details such as the number of active, available, disabled, suspect, or inoperable devices. This information can be useful for capacity planning and resource management. The system also reports the percentage of available modems, HDLC channels, or DSPs within a device or device group, to enable immediate detection of modem, HDLC, or DSP failure.
The following host cards support this feature:
• Series56 II, and Series56 III Digital Modem
• MutiDSP
• Hybrid Access (HDLC2-EC)
The following object has been added to the Ascend Enterprise MIB ( ascend.mib
): resourcesGroup OBJECT IDENTIFIER ::= { ascend 27 }
Ascend Service Management MIB (srvcmgmt.mib)
Enables you to manage Dialed Number Information Service (DNIS) services on the TAOS unit. When the DNIS management mode is enabled, Network Management Stations (NMS) such as NavisAccess manages the TAOS unit’s modem and HDLC resources.
APX 8000/MAX TNT/DSLTNT Administration Guide 6-15
SNMP Administration
Configuring SNMP access and security
Ascend Session MIB (session.mib)
Contains a table of entries for the status of each session in the system, including the IP address, type of session (PPP, MPP, Telnet, and so on), and MPP statistics.
Ascend UDS3 Profile MIB (mibuds3net.mib)
Part of the Ascend MIB Configuration group (group 23), this MIB corresponds to the UDS3 profile in the command line interface.
Ascend WAN MIB (wan.mib)
Assigns the SNMP Object IDs (OIDs) for the WAN interfaces.
Ascend WAN Dialout MIB (wandialout.mib)
Enables you to monitor the packets the TAOS unit receives that causes it to dialout.
Modified method for adding SNMP object IDs
Previously, algorithms used to assign Object IDs to new MIB members could result in dictionary conflicts across TAOS platforms and software versions. New methodologies make such conflicts much less likely. The MIB files distributed with the TAOS unit’s ensure that
SNMP managers begin using the newer dictionaries that will be maintained across future upgrades.
Ascend Enterprise traps
Defines Ascend-specific traps that alert NMS when certain events have occurred on the TAOS unit, such as when a Telnet session fails to authenticate, the TAOS unit is reset, or a Frame
Relay DLCI is brought up or torn down.
Configuring SNMP access and security
The SNMP profile contains SNMP-readable information related to the unit itself and its SNMP security. There are two levels of security: community strings, which must be known by a community of SNMP managers to access the box, and address security, which excludes SNMP access unless it is initiated from a specified IP address.
These are the related parameters:
SNMP enabled = no read-community = public read-write-community = write enforce-address-security = no read-access-hosts = [ 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0
0.0.0.0 ] write-access-hosts = [ 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0
0.0.0.0 ]
6-16 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
Configuring SNMP access and security
contact = "" location = ""
SNMP profile configuration overview
Table 6-2 provides some background information on tasks you may need to perform to
configure SNMP on the TAOS unit. For complete details on each parameter, see the APX
8000/MAX TNT/DSLTNT Reference.
Table 6-2. SNMP profile configuration tasks
Task
Enabling SNMP access
Setting community strings
Setting up and enforcing address security
Specifying who to contact about problems and the location of the unit
Specifying a queue depth
Description
If the enabled parameter in the SNMP profile is set to No
(the default), the TAOS unit cannot be accessed by SNMP utilities.
The read-community parameter specifies the SNMP community name for read access (up to 32 characters), and the read-write-community parameter specifies SNMP community name for read/write access.
If the enforce-address-security parameter is set to No (its default value), any SNMP manager that presents the right community name will be allowed access. If it is set to Yes, the TAOS unit checks the source IP address of the SNMP manager and allows access only to those IP addresses listed in the read-access-host and write-access-host arrays.
Each array can include up to five host addresses.
The contact and location fields are SNMP readable and settable, and should indicate the person to contact about this unit, and its location.
The default queue depth for SNMP requests is zero, which means the packets will not be dropped, no matter how busy the SNMP subsystem gets. If the queue were to grow too large in an extremely loaded routing environment, the system could ultimately run out of memory. Valid values for the queue depth are 0–1024.
APX 8000/MAX TNT/DSLTNT Administration Guide 6-17
SNMP Administration
Setting up SNMP traps
Sample SNMP profile
This example enables SNMP access, enforces address security, and prevents write access: admin> read snmp
SNMP read admin> list enabled = no read-community = public read-write-community = write enforce-address-security = no read-access-hosts = [ 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0
0.0.0.0 ] write-access-hosts = [ 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0
0.0.0.0 ] contact = "" location = "" admin> set enabled = yes admin> set enforce-address-security = yes admin> set read-access 1 = 10.2.3.4 admin> set read-access 2 = 10.2.56.123 admin> set queue-depth = 32 admin> write
SNMP written
Setting up SNMP traps
An SNMP trap is a mechanism for reporting system change in real time, such as reporting an incoming call. When a trap is generated by some condition, a traps-PDU (protocol data unit) is sent across the Ethernet to the SNMP manager.
You can configure the TAOS unit to send traps to an SNMP manager by specifying the address of the manager in a Trap profile. Traps can be enabled or disabled by class (error events, port state change events, or security events) or individually.
The following parameters relate to setting SNMP traps:
TRAP host-name* = "" community-name = "" host-address = 0.0.0.0
alarm-enabled = yes security-enabled = no port-enabled = no slot-enabled=no
For details on the actual events that generate traps in the various classes, see the Ascend
Enterprise MIB, or see the APX 8000/MAX TNT/DSLTNT Reference.
6-18 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
Setting up SNMP traps
TAOS unit trap support
The TAOS unit does not support the systemUseExceeded
trap.
Port-State change events are currently not applicable to the TAOS unit. These include:
• portInactive
• portDualDelay
• portWaitSerial
• portHaveSerial
• portRinging
• portCollectDigits
• portWaiting
• portConnected
• portCarrier
• portLoopback
• portAcrPending
• portDteNotReady
• portUseExceeded
In addition, the TAOS unit does not support billing features that include these traps:
• portUseExceeded
• systemUseExceeded
APX 8000/MAX TNT/DSLTNT Administration Guide 6-19
SNMP Administration
Setting up SNMP traps
Individual SNMP traps
Individual traps are enabled by default. The following parameters determine which traps are forwarded to an SNMP manager:
Parameter Meaning
Slot-Enabled The system generates a trap when a slot card is brought up or down.
Slot-Card-Reset-Enabled An SNMP user can view the Fatal Log table, and the TAOS unit can inform the user of a reason for a restart when one is available.
The following SNMP elements have been introduced to support this feature:
• The fatalLogTable
object
• The slotCardResetTrap
trap
The sysLastRestartReasonTrap
include fatalLogIndex
and sysAbsoluteCurrentTime
in its definition: sysLastRestartReasonTrap TRAP-TYPE
ENTERPRISE ascend
VARIABLES { sysLastRestartReason, fatalLog-
Index,
sysAbsoluteCurrentTime }
DESCRIPTION "This trap is sent to all managers having the
alarm condition enabled if the
sysLastRestartReason is not unknown
(value of 0)."
::= 26
A new slotCardResetTrap trap has been defined to inform the MIB manager that a slot card has been reset: slotCardResetTrap TRAP-TYPE
ENTERPRISE ascend
VARIABLES { fatalLogIndex, fatalLogReason,
sysAbsoluteCurrentTime, slotIndex
}
DESCRIPTION "This trap is sent to all managers having the
alarm condition enabled"
Coldstart-Enabled
Warmstart-Enabled
Linkdown-Enabled
The system generates a trap when the TAOS unit reinitializes itself such that the configuration of the SNMP manager or the system itself might be altered.
The system generates a trap when the TAOS unit reinitializes itself such that neither the configuration of SNMP manager or the system itself is altered.
The system generates a trap when a failure occurs in a communication link between the unit and the SNMP manager.
6-20 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
Setting up SNMP traps
Parameter Meaning
Linkup-Enabled
Ascend-Enabled
Call-Log-Dropped-Pkt-
Enabled
Console-Enabled
Console-State-Change
The system generates a trap when the communication link between the unit and the SNMP manager comes back up.
(Also known as the Ascend Enterprise trap.) When both this parameter and Port-Enabled are set to Yes, a trap is generated to indicate a change of state in a host interface. All port connections are monitored in a state machine and reported via this trap.
If enabled (the default), the system generates a trap when the value of the callLoggingDroppedPacketCount
variable in the call-logging MIB is changed from 0 to 1 (which indicates that packets are being dropped) or from 1 to 0 (which indicates that packets are no longer being dropped). SNMP management stations can obtain the value of the variable at any time by using SNMP
Get.
The system generates a trap when the console has changed state.
The console entry can be read to see what its current state is.
The SNMP agent on the TAOS sends the console’s IP address in addition to the console index in the Console-State-Change trap.
The Console-State-Change trap carries the information displayed in the following example:
1999-07-02 12:07:26 eng-fast-4.ascend.com
[192.168.25.4] enterprises.529:
Enterprise Specific Trap (12)Uptime:0:16:43 enterprises.529.8.2.1.1.2=2 enterprises.529.12.2.1.4.2=IpAddress:10.40.40.133
Config-Change-Enabled Enables or disables the configuration-change trap (Trap 30). The trap is enabled by default, which causes the system to issue the trap whenever the system configuration is modified or a new software version is loaded. If the parameter is set to no , the system does not issue the trap for those events. An SNMP management station can receive a Trap (30) and a string containing the date, time, and information about the user that changed the configuration.
OSPF-Set-Trap-Enabled For an OSPF trap to be generated when the trap condition occurs,
OSPF traps must be enabled, either in the Trap profile or by setting the corresponding bit in the new MIB object, ospfSetTrap
, defined in RFC 1850.
Use-Exceeded-Enabled The system generates a trap when a specific port has exceeded the number of DS0 minutes allocated to it, or the system DS0 usage has been exceeded.
Password-Enabled
FR-Linkup-Enabled
When both this parameter and Security-Enabled are set to Yes, all failed Telnet login attempts generate a trap.
If both this parameter and Alarm-Enabled are set to Yes, a trap is sent whenever a DLCI is brought up.
FR-Linkdown-Enabled If both this parameter and Alarm-Enabled are set to Yes, a trap is sent whenever a DLCI is brought down.
APX 8000/MAX TNT/DSLTNT Administration Guide 6-21
SNMP Administration
Setting up SNMP traps
Parameter Meaning
Event-Overwrite-Enabled The system generates a trap when a new event has overwritten an unread event. This trap is sent only for systems which support the
Ascend accounting MIB. Once sent, additional overwrites will not cause another trap to be sent until at least one table’s worth of new events have occurred.
RADIUS-Change-
Enabled
The system generates a trap when a new RADIUS server is being accessed. This trap returns the objectID and IP address of the new server.
Suspect-Access-Resource
-Enabled
Description: Specifies that whenever a terminating modem has received four successive calls for which it cannot establish a connection, the unit sends a trap to all SNMP managers in the alarm group.
Once the managing TAOS unit sends the trap, the suspect modem is not assigned to terminate calls until all available resources are exhausted. For example, if a modem drops five calls, the system generates the trap and places the offending modem at the end of the list of available terminating resources.
Usage: Specify one of the following values:
• yes
directs the TAOS to send the suspectAccessResource
trap when a terminating modem card has received four or more calls for which it could not establish a connection.
• no
instructs the TAOS not to send the suspectAccessResource
trap.
Example:
set suspect-access-resource-enabled = yes
Dependencies: The Suspect-Access-Resource-Enabled parameter has an effect only on TAOS units with one or more of the following slot cards installed:
• Series56 II, and Series56 III Digital Modem
• MultiDSP
Location: Trap
Mcast-Monitor-Enabled The system generates a trap when multicast heartbeat monitoring is configured and the system did not receive the configured number of heart-beat packets on a multicast interface.
LAN-Modem-Enabled The system generates a trap when a digital modem is moved to the suspect list.
Dirdo-Enabled The system generates a trap when a T-Online call comes in and no answer/subaddress has been received.
Slot-Profile-Change-
Enabled
The system generates a trap when a Slot-State profile is created due to slot insertion, or the current-state transitions into
Oper-State-Down, Oper-State-Up, Oper-State-Dump, or
Oper-State-None states.
6-22 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
Setting up SNMP traps
Parameter Meaning
Power-Supply-Enabled The system generates a trap when a power supply module is added or removed.
Multishelf-Enabled The system generates a trap when a master shelf detects up/down state changes of the peer shelf in a multishelf configuration.
Authentication-Enabled The system generates a trap when an authentication failure occurs.
Overview of RFC 1850 OSPF traps
TAOS units support OSPF traps as defined in RFC 1850, OSPF Version 2 Management
Information Base. For an OSPF trap to be generated when the trap condition occurs, OSPF traps must be enabled, either in the Trap profile or by setting the corresponding bit in the new
MIB object, ospfSetTrap , defined in RFC 1850. In addition, the individual trap that represents the trap condition must be enabled.
Overview of trap definitions
Following are the relevant parameters (shown with default values) in an ospfSet Trap profile:
[in TRAP/""] ospf-enabled = no ospf-if-config-error-enabled = no ospf-if-auth-failure-enabled = no ospf-if-state-change-enabled = no ospf-if-rx-bad-packet = no ospf-tx-retransmit-enabled = no ospf-nbr-state-change-enabled = no ospf-virt-if-config-error-enabled = no ospf-virt-if-auth-failure-enabled = no ospf-virt-if-state-change-enabled = no ospf-virt-if-rx-bad-packet = no ospf-virt-if-tx-retransmit-enabled = no ospf-virt-nbr-state-change-enabled = no ospf-originateLsa-enabled = no ospf-maxAgeLsa-enabled = no ospf-lsdb-overflow-enabled = no ospf-approaching-overflow-enabled = no
Parameter
OSPF-enabled
OSPF-if-config-errorenabled
Specifies
Enable/disable generation of OSPF traps. When set to no
(the default), no OSPF traps are generated regardless of individual
OSPF trap settings in the profile. When set to yes
, trap generation depends on whether the specific OSPF trap is enabled.
Enable/disable trap generation if a packet has been received on a nonvirtual interface from a router whose configuration conflicts with this router’s configuration. The system generates this trap when it detects configuration error types from 1 to 9, as defined in
RFC 1850. Generation of the trap typically indicates a failure to form an adjacency, although this is not always the case. Traps for error type 10 (optionsMismatch) are not currently supported.
(OSPF Trap 4)
APX 8000/MAX TNT/DSLTNT Administration Guide 6-23
SNMP Administration
Setting up SNMP traps
Parameter Specifies
OSPF-if-auth-failureenabled
OSPF-if-state-changeenabled
Enable/disable trap generation if a packet has been received on a nonvirtual interface from a router whose authentication key or authentication type conflicts with this router’s authentication key or authentication type. (OSPF Trap 6)
Enable/disable trap generation if the state of a nonvirtual OSPF interface has changed. This trap is generated when the interface state regresses (for example, goes from Dr to Down) or progresses to a terminal state (Point-to-Point, DR Other, Dr, or Backup).
(OSPF Trap 16)
OSPF-if-rx-bad-packet Enable/disable trap generation if an OSPF packet has been received on a nonvirtual interface that cannot be parsed. (OSPF
Trap 8)
OSPF-tx-retransmitenabled
Enable/disable trap generation if an OSPF packet has been retransmitted on a nonvirtual interface. All packets that are retransmitted are associated with a link-state database (LSDB) entry. The LS type, LS ID, and Router ID are used to identify the
LSDB entry. (OSPF Trap 10)
OSPF-nbr-state-changeenabled
Enable/disable trap generation if the state of a nonvirtual OSPF neighbor has changed. This trap is generated when the neighbor state regresses (for example, changes from Attempt or Full to
1-Way or Down) or progresses to a terminal state (for example,
2-Way or Full). When an neighbor transitions from or to Full on nonbroadcast multiaccess (NBMA) and broadcast networks, the trap is generated by the designated router. A designated router transitioning to Down is noted by OSPFIfStateChange. (OSPF
Trap 2)
OSPF-virt-if-config-error
-enabled
Enable/disable trap generation if a packet has been received on a virtual interface from a router whose configuration parameters conflict with this router’s configuration parameters. The system generates this trap when it detects configuration error types from 1 to 9, as defined in RFC 1850. Generation of the trap typically indicates a failure to form an adjacency, although this is not always the case. Traps for error type 10 (optionsMismatch) are not currently supported. (OSPF Trap 5)
OSPF-virt-if-auth-failureenabled
Enable/disable trap generation if a packet has been received on a virtual interface from a router whose authentication key or authentication type conflicts with this router’s authentication key or authentication type. (OSPF Trap 7)
OSPF-virt-if-state-change
-enabled
Enable/disable trap generation if the state of an OSPF virtual interface has changed. (OSPF Trap 1)
OSPF-virt-if-rx-badpacket
Enable/disable trap generation if an OSPF packet has been received on a virtual interface that cannot be parsed. (OSPF Trap
9)
6-24 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
Setting up SNMP traps
Parameter
OSPF-virt-if-txretransmit-enabled
OSPF-virt-nbr-statechange-enabled
OSPF-originateLsaenabled
OSPF-maxAgeLsaenabled
OSPF-lsdb-overflowenabled
OSPF-approachingoverflow-enabled
Specifies
Enable/disable trap generation if an OSPF packet has been retransmitted on a virtual interface. All packets that are retransmitted are associated with an LSDB entry. The LS type, LS
ID, and Router ID are used to identify the LSDB entry. (OSPF
Trap 11)
Enable/disable trap generation if the state of an OSPF virtual neighbor has changed. (OSPF Trap 3)
Enable/disable trap generation if a new LSA has been originated by this router due to a topology change. (OSPF Trap 12)
Enable/disable trap generation if an LSA in the router’s link-state database has aged to MaxAge. (OSPF Trap 13)
Enable/disable trap generation if the number of LSAs in the router’s link-state database has exceeded OSPFExtLsdbLimit.
(OSPF Trap 14)
Enable/disable trap generation if the number of LSAs in the router’s link-state database has exceeded 90 percent of
OSPFExtLsdbLimit. (OSPF Trap 15)
Example of setting traps in the Trap profile
The following commands cause the system to generate traps when the router receives a packet from an OSPF router in which a configuration mismatch (such as an invalid OSPF version number or an address conflict) or an authentication failure occurs: admin> read trap monitor-ospf
TRAP/monitor-ospf read admin> set ospf-enabled = yes admin> set ospf-if-config-error-enabled = yes admin> set ospf-if-auth-failure-enabled = yes admin> write
TRAP/monitor-ospf written
SNMP support for OSPF traps
In addition to the Trap profile changes, a new MIB ( rfc1850.mib
) is distributed as part of this release. Management stations and browsers used to manage OSPF load rfc1850.mib
instead of the old rfc1253.mib
. A new MIB object, ospfSetTrap
is defined according to RFC 1850 for enabling trap events:
.iso.org.dod.internet.mgmt.mib-2. ospf.ospfTrap.ospfTrapControl.ospfSetTrap
This object defaults initially to the octet string {’\0x0’, ’0x0’, ’0x0’, ’0x0’} (or the hex value 0x0), which disables all trap events. The value of this object is stored in
NVRAM.
APX 8000/MAX TNT/DSLTNT Administration Guide 6-25
SNMP Administration
Setting up SNMP traps
SNMP support for the Idle Time variable
In addition to displaying the idle time for an active session by using the userstat -o %t command, the same information is made available to SNMP management stations through the ssnActiveIdleTime
object in the sessionActiveTable
. The object uses Object ID sessionActiveEntry.8
. It shows the time the session has been idle in 0.01-second increments). Following is the object definition: ssnActiveIdleTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "The time, current session has been idle.
For non-TNT and non-Max platforms 0 is always
reported."
::= { sessionActiveEntry 8 }
SNMP trap configuration overview
Table 6-3 provides some background information on tasks you may need to perform to
configure the TAOS unit to send SNMP traps. For complete details on each parameter, see the
APX 8000/MAX TNT/DSLTNT Reference.
Table 6-3. SNMP trap configuration tasks
Task Description Associated parameters
Specifying the host running the SNMP manager
The Host-Name field is the index for the Trap profile, so it must contain a name. If DNS or YP/NIS is supported, it can contain the hostname of a system running an SNMP manager. If the host-address field contains an IP address, the specified name is not used to actually locate the host.
The host-address can specify an IP address of the destination host. If DNS or YP/NIS is not supported, it must contain the host’s address.
Host-Name
The community string for communicating with the SNMP manager
The community name field must contain the community name associated with the SNMP PDU.
Classes of traps to be sent to the specified host
The next three fields specify whether the TAOS unit traps alarm events, security events, and port events and sends a trap-PDU to the SNMP manager. For a description of the events that generate these traps, see the APX 8000/MAX TNT/DSLTNT Reference.
Community-Name
Alarm-Enabled
Security-Enabled
Port-Enabled
6-26 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
Setting up SNMP traps
Table 6-3. SNMP trap configuration tasks (continued)
Task
Individual traps to be sent to the specified host
Description Associated parameters
In addition to enabling whole classes of traps, you can specify individual SNMP traps to forward to an
SNMP manager. Individual traps are enabled by default.
Slot-Enabled
Coldstart-Enabled
Warmstart-Enabled
Linkdown-Enabled
Linkup-Enabled
Ascend-Enabled
Console-Enabled
Use-Exceeded-Enabled
Password-Enabled
FR-Linkup-Enabled
FR-Linkdown-Enabled
Event-Overwrite-Enabled
RADIUS-Change-Enabled
Mcast-Monitor-Enabled
LAN-Modem-Enabled
Dirdo-Enabled
Slot-Profile-Change-Enabled
Power-Supply-Enabled
Multishelf-Enabled
Authentication-Enabled
Example SNMP trap configuration
In the following example, the host-name is used only as a profile index, not to locate the actual host on the network. A community name is specified, security-class traps are added to the default alarm-class traps, and this host receives a trap if the multishelf link goes down. admin> new trap
TRAP/"" read admin> list host-name* = "" community-name = "" host-address = 0.0.0.0
alarm-enabled = yes security-enabled = no port-enabled = no slot-enabled = no admin> set host-name = security-traps admin> set community-name = Ascend admin> set host-address = 10.2.3.4 admin> set security-enabled = yes admin> set slot-enabled = yes admin> write
TRAP/security-traps written
APX 8000/MAX TNT/DSLTNT Administration Guide 6-27
SNMP Administration
Managing SNMP interfaces
Because security traps and the Password-Enabled and Authentication-Enabled individual traps are enabled, two traps are sent when either of the related conditions occur. The individual trap provides additional information about the specific event that triggered the trap.
Managing SNMP interfaces
The TAOS unit supports the Interface MIB based on RFC 2233, which supersedes the SNMP
MIB-II defined in RFC1213. The interface table contains only the system’s physical interfaces and nailed (permanent) interfaces.
The index value of an interface does not change following a system reset, and if an entry is removed from the interface table dynamically, its index value is not reused until the management station has been reinitialized. The interface table does not contain virtual circuit interfaces, such as a Frame Relay datalink configured on a channelized DS1 interface.
The If-Admin command is a diagnostic tool for managing SNMP interfaces. To see its usage: admin> if-admin usage: if-admin -a|d|l|r|u|? [ interface ]
-a list (a)available SNMP interface numbers
-d administratively (d)own an SNMP interface
-l (l)ist SNMP interface/device address mapping
-r (r)eset SNMP interface/device address mappings
-u administratively (u)p an SNMP interface
-? display this summary
To see a list of available SNMP interface numbers, use the
-a
option: admin> if-admin -a
Available SNMP interface numbers
118 - infinity
To see a list of all SNMP interface numbers assigned by the system: admin>if-admin -l
SNMP-IF DEVICE ADDRESS STATUS
1 - { 1 17 1} 1
2 - { 1 1 1 } 1
3 - { 1 1 2 } 1
4 - { 1 1 3 } 1
5 - { 1 1 4 } 1
6 - { 1 1 5 } 1
7 - { 1 1 6 } 1
8 - { 1 1 7 } 1
9 - { 1 1 8 } 1
..
..
To bring an SNMP interface up or down, use the If-Admin command with the
-d
option, and specify the interface number. For example: admin> if-admin -d 2 interface 2 state change forced
6-28 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
Managing SNMP interfaces
To bring a downed device back up, use the If-Admin command with the
-u
option, and specify the interface number. For example: admin> if-admin -u 2 interface 2 state change forced
Initiating interface state changes
To bring an SNMP interface up or down, use the If-Admin command.
To bring an interface down: admin> if-admin -d 2 interface 2 state change forced
To bring an interface up: admin> if-admin -u 2 interface 2 state change forced
Resetting SNMP interface table sequentially
By default, the SNMP interface table is built as slot-cards are installed in the TAOS unit. The
If-admin command
–r option enables the administrator to reset the order of the table to be sequential based on slot number.
When you use the If-Admin command with the –r option, the order of the SNMP interface table is reset to a deterministic order. The T1 lines will appear in the SNMP interface table before the packet-passing interfaces such as Ethernet, modem, and HDLC cards. The T1 line interfaces will be ordered based on slot number order.
Note:
You must reset the TAOS unit for the new order to take effect.
For example: admin> if-admin -r
SNMP interface mappings reset.
Reset system in order to take effect.
Note:
This command should not fail, but if for some reason it does, attempt it again. If it fails a second time, you should bring down all slot cards (
Slot –d
), remove all slot cards by using
Slot –r
, reset the system, and run the
If-admin – r command again.
APX 8000/MAX TNT/DSLTNT Administration Guide 6-29
SNMP Administration
Ascend MIB hierarchy
Ascend MIB hierarchy
Figure 6-1 illustrates the Ascend MIB hierarchy.
Figure 6-1. Ascend MIB hierarchy iso (1) org (3) dod (6) internet (1) private (4) enterprise (1) ascend (529) products (1) slots (2) hostTypes (3) advancedAgent(4) lanTypes (5) doGroup (6) hostStatus (7) console (8) systemStatusGroup (9) eventGroup (10) callStatusGroup (11) sessionStatusGroup (12) radiusGroup (13) mCastGroup (14) lanModemGroup (15) firewallGroup (16) wanDialoutPkt (17) powerSupply (18) multiShelf (19) miscGroup (20) asgGroup (21) flashGroup (22) configuration (23) atmpGroup (24) callLoggingGroup (25) srvcMgmtGroup (26)
products (1)
The products
group is defined as: products ::= { enterprise ascend1 }
with this value:
1.3.6.1.4.1.529.1
It contains the following objects:
multiband (1) max (2) pipeline (3) max-tnt (4) dslTnt (5)
6-30 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
Ascend MIB hierarchy
slots (2)
The slots
group is defined as: slots ::= { enterprise ascend 2 }
with this value:
1.3.6.1.4.1.529.2
It contains the following objects:
slotNumber(1) slotTable(2) slotEntry (1)
slotIndex (1)
slotName (2)
slotType (3)
slotFixed (4)
slotItems (5)
slotSpecific (6)
slotSerialNumber (7)
slotStatus (8)
slotLastChange (9) slotItemTable (3) slotItemEntry (1)
slotItemSlotIndex (1)
slotItemIndex (2)
slotItemFirstIf (3)
slotItemIfCount (4)
slotItemSpecific (5)
slotItemStatus (6) slotIfTable (4) slotifEntry (1) slotSlotIfIndex (1)
slotIfSlotIndex (2)
slotIfItemIndex (3)
hostTypes (3)
The hostTypes
group is defined as: hostTypes ::= { enterprise ascend 3 }
with this value:
1.3.6.1.4.1.529.3
It contains the following objects:
hostTypeAny (1) hostTypeDual (2) hostTypeQuad (3) hostTypeAim2 (4) hostTypeAim6 (5)
APX 8000/MAX TNT/DSLTNT Administration Guide 6-31
SNMP Administration
Ascend MIB hierarchy
advancedAgent (4)
The advancedAgent
group is defined as: advancedAgent ::= { enterprise ascend 4 }
with this value:
1.3.6.1.4.1.529.1
It contains the following objects:
wanUseTrunkGroups(20) wanLineTable (21) wanLineEntry (1)
wanLineIfIndex (1) wanLineName (2) wanLineType (3) wanLineChannels (4) wanLineState (5) wanLineStateString (6) wanLineActiveChannels (7) wanLineUsage (8) wanLineHuntGrpPhoneNumber1 (9) wanLineHuntGrpPhoneNumber2 (10) wanLineHuntGrpPhoneNumber3 (11) wanLineAvailableChannels (12) wanLineSwitchedChannels (13) wanLineDisabledChannels (14) wanLineNailedChannels (15) wanLineOutOfServiceChannels (16) wanLineChannelTable(22) wanLineChannelEntry (1)
wanLineChannelIfIndex (1)
wanLineChannelIndex (2)
wanLineChannelState (3)
wanLineChannelStateString (4)
wanLineChannelErrorCount (5)
wanLineChannelUsage (6)
wanLineChannelTrunkGroup (7)
wanLineChannelPhoneNumber (8)
wanLineChannelSlot (9)
wanLineChannelPort (10)
wanLineChannelNailedState (11) wanAvailableChannels (23) wanSwitchedChannels (24) wanDisabledChannels (25) wanActiveChannels (26) wanNailedChannels (27) wanOutOfServiceChannels (28)
lanTypes (5)
The lanTypes
group is defined as: products ::= { enterprise ascend 5}
with this value:
1.3.6.1.4.1.529.5
The Ascend MIB lanTypes
group contains the following objects:
lanTypeAny (1) lanTypeEthernet (2) lanTypeEtherData (3)
6-32 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
Ascend MIB hierarchy
doGroup (6)
The doGroup
is defined as: products ::= { enterprise ascend 6 }
with this value:
1.3.6.1.4.1.529.6
The Ascend MIB doGroup
contains the following objects:
doTable (1) doEntry (1) doSlotIndex (1) doItemIndex (2) doDial (3) doHangUp (4) doAnswer (5) doExtendBW (6) doContractBW (7) doBegEndRemoteLB (8) doBegEndBERT (9) doResynchronize (10)
hostStatus (7)
The hostStatus
group is defined as: hostStatus ::= { enterprise ascend 7 } with this value:
1.3.6.1.4.1.529.7
It contains the following objects:
hostStatusTable (1) hostStatusEntry (1) hostStatusSlotIndex (1)
hostStatusItemIndex (2)
hostStatusLocalName (3)
hostStatusDialNum (4)
hostStatusCallType (5)
hostStatusCallMgm (6)
hostStatusDataSvc (7)
hostStatusCallState (8)
hostStatusRemName (9)
hostStatusChannels (10)
hostStatusDuration (11)
console (8)
The console
group is defined as: console ::= { enterprise ascend 8 }
with this value:
1.3.6.1.4.1.529.8
It contains the following objects:
consoleNumber (1) consoleTable (2) consoleEntry (1)
consoleIndex (1)
consoleIf (2)
consoleType (3)
consoleSecurity (4)
consoleSpecific (5)
APX 8000/MAX TNT/DSLTNT Administration Guide 6-33
SNMP Administration
Ascend MIB hierarchy
systemStatusGroup (9)
The systemStatusGroup
is defined as: systemStatusGroup ::= { enterprise ascend 9 }
with this value:
1.3.6.1.4.1.529.9
It contains the following objects:
sysAbsoluteStartupTime (1) sysSecsSinceStartup (2) sysMibVersionNum (3) sysMibMinorRevNum (4) sysConfigTftp (5)
sysConfigTftpCmd (1)
sysConfigTftpStatus (2)
sysConfigTftpHostAddr (3)
sysConfigTftpFilename (4)
sysConfigTftpPort (5)
sysConfigTftpParameter (6) sysConfigRadius (6)
sysConfigRadiusCmd (1)
sysConfigRadiusStatus (2) sysAbsoluteCurrentTime (7) sysReset (8) sysLoadName (9) sysAuthPreference (10) sysSPROM (11)
sysSPROMSerialNumber (1)
sysSPROMOptions1 (2)
sysSPROMOptions2 (3)
sysSPROMCountries1 (4) resetStat (12)
resetStatEther (1)
resetStatWAN (2)
resetStatAll (3) sysLastRestartReason (13)
eventGroup (10)
The eventGroup
is defined as: eventGroup ::= { enterprise ascend 10 } with this value:
1.3.6.1.4.1.529.10
6-34 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
Ascend MIB hierarchy
It contains the following objects:
eventMaximumNumberOfEvents (1) eventOldestEventIdNumber (2) eventLatestEventIdNumber (3) eventTable(4) eventEntry (1)
eventIdNumber (1)
eventTimeStamp (2)
eventType (3)
eventCallReferenceNum (4)
eventDataRate (5)
eventSlotNumber (6)
eventSlotLineNumber (7)
eventSlotChannelNumber (8)
eventModemSlotNumber (9)
eventModemOnSlot (10)
eventCurrentService (11)
eventUserName (12)
eventUserIPAddress (13)
eventUserSubnetMask (14)
eventDisconnectReason (15)
eventCallCharge (17)
eventCalledPartyID (18)
eventCallingPartyID (19)
eventInOctets (20)
eventOutOctets (21)
eventMultiLinkID (22)
eventXmitRate (23) eventCurrentActiveCalls (5) eventCurrentActiveSessions ( 6) eventTotalCalls ( 7) eventTotalSessions ( 8) eventTotalCallsAnswered ( 9) eventTotalCallsOriginated ( 10) eventTotalCallsCleared ( 11) eventTotalBaudRateChanges ( 12) eventTotalServiceChanges ( 13) eventTotalNameChanges ( 14) eventTotalNoModems ( 15)
callStatusGroup (11)
The callStatusGroup
is defined as: callStatusGroup ::= { enterprise ascend 11 }
with this value:
1.3.6.1.4.1.529.11
APX 8000/MAX TNT/DSLTNT Administration Guide 6-35
SNMP Administration
Ascend MIB hierarchy
It contains the following objects:
callStatusMaximumEntries (1) callStatusTable (2) callStatusEntry (1)
callStatusIndex (1)
callStatusValidFlag (2)
callStatusStartingTimeStamp (3)
callStatusCallReferenceNum (4)
callStatusDataRate (5)
callStatusSlotNumber (6)
callStatusSlotLineNumber (7)
callStatusSlotChannelNumber (8)
callStatusModemSlotNumber (9)
callStatusModemOnSlot (10)
callStatusIfIndex (11)
callSessionIndex (12)
callStatusType (13)
callStatusXmitRate (14)
callStatusPortType (15) callStatusHighWaterMark (3) callCurrentAnalogOutgoing (4) callCurrentAnalogIncoming (5) callCurrentDigitalOutgoing (6) callCurrentDigitalIncoming (7) callCurrentFROutgoing (8) callCurrentFRIncoming (9) callTotalAnalogOutgoing (10) callTotalAnalogIncoming (11) callTotalDigitalOutgoing (12) callTotalDigitalIncoming (13) callTotalFROutgoing (14) callTotalFRIncoming (15) callActiveTable (16) callActiveEntry (1)
callActiveCallReferenceNum (1)
callActiveIndex (2)
callActiveValidFlag (3)
callActiveStartingTimeStamp (4)
callActiveDataRate (5)
callActiveSlotNumber (6)
callActiveSlotLineNumber (7)
callActiveSlotChannelNumber (8)
callActiveModemSlotNumber (9)
callActiveModemOnSlot (10)
callActiveIfIndex (11)
callActiveSessionIndex (12)
callActiveType (13)
callActiveXmitRate (14)
callActivePortType (15)
sessionStatusGroup (12)
The sessionStatusGroup is defined as: sessionStatusGroup ::= { enterprise ascend 12 }
with this value:
1.3.6.1.4.1.529.12
It contains the following objects:
ssnStatusMaximumSessions (1) sessionStatusTable (2) sessionStatusEntry (1)
ssnStatusIndex (1)
ssnStatusValidFlag (2)
ssnStatusUserName (3)
ssnStatusUserIPAddress (4)
ssnStatusUserSubnetMask (5)
ssnStatusCurrentService (6)
ssnStatusCallReferenceNum (7) sessionActiveTable (3) sessionActiveEntry (1)
ssnActiveCallReferenceNum (1)
ssnActiveIndex (2)
ssnActiveValidFlag (3)
ssnActiveUserName (4)
ssnActiveUserIPAddress (5)
ssnActiveUserSubnetMask (6)
ssnActiveCurrentService (7) mppActiveStatsTable (4) mppActiveStatsEntry (1)
mppStatsMpID (1)
mppStatsRemoteName (2)
mppStatsQuality (3)
mppStatsBandwidth (4)
mppStatsTotalChannels (5)
mppStatsCLU (6) mppStatsALU (7)
mppStatsStartingTimeStamp (8)
6-36 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
Ascend MIB hierarchy
radiusGroup (13)
The radiusGroup
is defined as: radiusGroup ::= { enterprise ascend 13 }
with this value:
1.3.6.1.4.1.529.13
It contains the following objects:
radiusNumAuthServers (1) radiusNumAcctServers (2) radiusAuthStatsTable (3) radiusAuthStatsEntry (1)
radAuthServerIndex (1)
radAuthLoginRqstSent (2)
radAuthOtherRqstSent (3)
radAuthRqstTimedOut (4)
radAuthOtherRqstTimedOut (5)
radAuthRspRcvd (6)
radAuthOtherRspRcvd (7)
radAuthUnexpRspRcvd (8)
radAuthBadRspRcvd (9)
radAuthAckRspRcvd (10)
radAuthHostIPAddress (11)
radAuthCurrentServerFlag (12) radiusAcctStatsTable (4) radiusAcctStatsEntry (1)
radAcctServerIndex (1)
radAcctRqstSent (2)
radAcctRqstTimedOut (3)
radAcctRspRcvd (4)
radAcctUnexpRspRcvd (5)
radAcctHostIPAddress (6) radAcctCurrentServerFlag (7) radiusNewNASPortIDFormat (5)
mCastGroup (14)
The mCastGroup is defined as: mCastGroup ::= { enterprise ascend 14 }
with this value:
1.3.6.1.4.1.529.14
It contains the following objects:
eartBeatMulticastGroupAddress (1) eartBeatSourceAddress (2) eartBeatSlotTimeInterval (3) eartBeatSlotCount (4) eartBeatPacketCount (5)
APX 8000/MAX TNT/DSLTNT Administration Guide 6-37
SNMP Administration
Ascend MIB hierarchy
lanModemGroup (15)
The lanModemGroup
is defined as: lanModemGroup ::= { enterprise ascend 15 }
with this value:
1.3.6.1.4.1.529.15
It contains the following objects:
availLanModem (1) availLanModemTable (2) availLanModemEntry (1)
availLanModemSlotIndex (1)
availLanModemPortIndex (2)
availLanModemUsedCount (3)
availLanModemBadCount (4)
availLanModemLast32 (5) suspectLanModem (3) suspectLanModemTable (4) suspectLanModemEntry (1)
suspectLanModemSlotIndex (1)
suspectLanModemPortIndex (2)
suspectLanModemUsedCount (3)
suspectLanModemBadCount (4)
suspectLanModemLast32 (5) disabledLanModem (5) disabledLanModemTable (6) disabledLanModemEntry (1)
disabledLanModemSlotIndex (1)
disabledLanModemPortIndex (2)
disabledLanModemUsedCount (3)
disabledLanModemBadCount (4)
disabledLanModemLast32 (5) deadLanModem (7) deadLanModemTable (8) deadLanModemEntry (1)
deadLanModemSlotIndex (1)
deadLanModemPortIndex (2)
deadLanModemState (3) busyLanModem (9) busyLanModemTable (10) busyLanModemEntry (1)
busyLanModemSlotIndex (1)
busyLanModemPortIndex (2)
busyLanModemUsedCount (3)
busyLanModemBadCount (4)
busyLanModemLast32 (5)
busyDirection (6) suspectTrapState (11)
firewallGroup (16)
The firewallGroup
is defined as: firewallGroup ::= { enterprise ascend 16 }
with this value:
1.3.6.1.4.1.529.16
It contains the following objects:
firewallStatus (1) firewallControl (2)
fwallCtrlRuleName ( 1)
fwallCtrlExecute ( 2)
fwallCtrlTimeOut ( 3)
fwallCtrlExtAddr ( 4)
fwallCtrlExtAddrMask ( 5)
fwallCtrlExtPort ( 6)
fwallCtrlExtPortMax ( 7)
fwallCtrlIntAddr ( 8)
fwallCtrlIntAddrMask ( 9)
fwallCtrlIntPort ( 10)
fwallCtrlIntPortMax ( 11)
fwallCtrlRoutAddr ( 12)
fwallCtrlAddrOpts (13)
6-38 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
Ascend MIB hierarchy
wanDialoutPkt (17)
The wanDialoutPkt
group is defined as: wanDialoutPkt ::= { enterprise ascend 17 }
with this value:
1.3.6.1.4.1.529.17
It contains the following objects:
wanDialoutPktTableSize (1) wanDialoutPktMaxSize (2) wanDialoutPktCount (3) wanDialoutPktTable (4) wanDialoutPktEntry (1)
wanDialoutPktIndex (1)
wanDialoutPktTime (2)
wanDialoutPktPhoneNumber (3)
wanDialoutPktProtocolType (4)
wanDialoutPktInfo (5)
powerSupply (18)
The powerSupply
group is defined as: powerSupply ::= { enterprise ascend 18 }
with this value:
1.3.6.1.4.1.529.18
It contains the following objects:
powerSupplyCount (1) powerSupplyTable (2) powerSupplyEntry (1)
powerSupplyIndex (1)
powerSupplyState (2)
powerSupplyOperationalState (3) powerSupplyStateTrapState (3) powerSupplyOperationalStateTrapState (4)
multiShelf (19)
The multiShelf
group is defined as: multiShelf ::= { enterprise ascend 19 } with this value:
1.3.6.1.4.1.529.19
It contains the following objects:
myShelfNumber (1) myShelfOperation (2) masterShelfNumber (3) multiShelfTableSize (4) multiShelfTable (5) multiShelfTable (1)
multiShelfIndex (1)
multiShelfState (2)
multiShelfResentFrames (3)
multiShelfNLinkUp (4)
multiShelfTxQs (5)
multiShelfTxSeq (6)
multiShelfRxSeq (7)
multiShelfTimerValue (8) multiShelfStateTrapState (6)
APX 8000/MAX TNT/DSLTNT Administration Guide 6-39
SNMP Administration
Ascend MIB hierarchy
miscGroup (20)
The miscGroup
is defined as: miscGroup ::= { enterprise ascend 20 }
with this value:
1.3.6.1.4.1.529.20
It contains the following objects:
iscGroupFRTable (1) iscGroupFREntry (1)
flashGroup (22)
The flashGroup
is defined as: flashGroup ::= { enterprise ascend 22 } with this value:
1.3.6.1.4.1.529.22
It contains the following objects:
flashDevice (1)
flashDevices (1)
flashDeviceTable (2) flashDeviceEntry (1)
flashDeviceIndex (1)
flashDeviceController (2)
flashDeviceSlot (3)
flashDeviceSize (4)
flashDeviceUsed (5)
flashDeviceState (6)
flashDeviceMaster (7)
flashDeviceFormatStatus (8)
flashDeviceDescription (9) flashFileTable (2) flashFileEntry (1)
flashFileIndex (1)
flashFileController (2)
flashFileCard (3)
flashFileSize (4)
flashFileStatus (5)
flashFileName (6) flashFileChecksum (7)
flashFileVersion (8)
flashFileAccess (9)
flashFileDateTimeStamp (10) flashOperation (3) flashOperationStatus (1)
flashOperationCommand (2)
flashOperationHost (3)
flashOperationDestFileName (4)
flashOperationSrcFileName (5)
flashOperationController (6)
flashOperationCard (7)
flashOperationLoadType (8)
6-40 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
Ascend MIB hierarchy
configuration (23)
The configuration
group is defined as: configuration ::= { enterprise ascend 23 }
with this value:
1.3.6.1.4.1.529.23
It contains the following objects:
mibinternetProfile (1) mibframeRelayProfile (2) mibanswerProfile (3) mibud3NetworkProfile (4) mibuds3NetworkProfile (5) mibcadslNetworkProfile (6) mibdadslNetworkProfile (7) mibsdslNetworkProfile (8) mibvdslNetworkProfile (9)
APX 8000/MAX TNT/DSLTNT Administration Guide 6-41
SNMP Administration
Ascend MIB hierarchy
mibinternetProfile (1)
The mibInternetProfile
has the value:
1.3.6.1.4.1.529.23.1
The mibInternetProfile
in the configuration
group contains the following objects:
ibinternetProfileTable (1)
MibinternetProfileEntry (1)
internetProfile__ipx_options__dial_query(52)
internetProfile__session_options__call_filter(65)
internetProfile__session_options__data_filter(66)
internetProfile__station (1)
internetProfile__active (2)
internetProfile__ipx_options__sap(51)
internetProfile__session_options__filter_persistence(67) internetProfile__session_options__idle_timer(68)
internetProfile__encapsulation_protocol(3)
internetProfile__called_number_type(4)
internetProfile__ipx_options__rip(50)
internetProfile__session_options__ts_idle_mode(69)
internetProfile__session_options__ts_idle_timer(70)
internetProfile__dial_number(5)
internetProfile__clid(6)
internetProfile__ipx_options__peer_mode(49)
internetProfile__session_options__backup(71)
internetProfile__session_options__secondary(72)
internetProfile__ip_options__ip_routing_enabled(7)
internetProfile__ip_options__vj_header_prediction(8)
internetProfile__ipx_options__ipx_routing_enabled(48)
internetProfile__session_options__atmp_gateway(73) internetProfile__session_options__max_call_duration(74)
internetProfile__ip_options__remote_address(9)
internetProfile__ip_options__local_address(10)
internetProfile__ip_options__tos_filter(47)
internetProfile__session_options__vtp_gateway(75)
internetProfile__session_options__blockcountlimit(76)
internetProfile__ip_options__routing_metric(11)
internetProfile__ip_options__preference(12)
internetProfile__ip_options__tos_options__apply_to(46)
internetProfile__session_options__blockduration(77)
internetProfile__session_options__max_atmp_tunnels(78)
internetProfile__ip_options__down_preference(13)
internetProfile__ip_options__private_route(14)
internetProfile__ip_options__tos_options__type_of_service(45)
internetProfile__session_options__max_vtp_tunnels(79)
internetProfile__session_options__redial_delay_limit(80)
internetProfile__ip_options__multicast_allowed(15)
internetProfile__ip_options__address_pool(16)
internetProfile__ip_options__tos_options__precedence(44)
internetProfile__session_options__ses_rate_type(81)
internetProfile__session_options__ses_rate_mode(82)
internetProfile__ip_options__ip_direct(17)
internetProfile__ip_options__rip(18)
internetProfile__ip_options__tos_options__active(43)
internetProfile__session_options__ses_adsl_cap_up_rate(83)
internetProfile__session_options__ses_adsl_cap_down_rate(84)
internetProfile__ip_options__route_filter(19)
internetProfile__ip_options__source_ip_check(20)
internetProfile__ip_options__client_default_gateway(42)
internetProfile__session_options__ses_adsl_dmt_up_rate(85)
internetProfile__session_options__ses_adsl_dmt_down_rate(86)
internetProfile__ip_options__ospf_options__active(21)
internetProfile__ip_options__ospf_options__area(22)
internetProfile__ip_options__client_dns_addr_assign(41)
internetProfile__session_options__rx_data_rate_limit(87)
internetProfile__session_options__tx_data_rate_limit(88)
internetProfile__ip_options__ospf_options__area_type(23)
internetProfile__ip_options__ospf_options__hello_interval(24)
internetProfile__ip_options__client_dns_secondary_addr(40)
internetProfile__telco_options__answer_originate(89)
internetProfile__telco_options__callback(90)
internetProfile__ip_options__ospf_options__dead_interval(25)
internetProfile__ip_options__ospf_options__priority(26)
internetProfile__ip_options__client_dns_primary_addr(39)
internetProfile__telco_options__call_type(91)
internetProfile__telco_options__nailed_groups(92)
internetProfile__ip_options__ospf_options__authen_type(27)
internetProfile__ip_options__ospf_options__auth_key(28)
internetProfile__ip_options__multicast_group_leave_delay(38)
internetProfile__telco_options__ft1_caller(93)
internetProfile__telco_options__force_56kbps(94)
internetProfile__ip_options__ospf_options__key_id(29)
internetProfile__ip_options__ospf_options__cost(30)
internetProfile__ip_options__multicast_rate_limit(37)
internetProfile__telco_options__data_service(95)
internetProfile__telco_options__call_by_call(96)
internetProfile__ip_options__ospf_options__down_cost(31)
internetProfile__ip_options__ospf_options__ase_type(32)
internetProfile__ip_options__ospf_options__non_multicast(36)
internetProfile__telco_options__billing_number(97)
internetProfile__telco_options__transit_number(98)
internetProfile__ip_options__ospf_options__ase_tag(33) internetProfile__ip_options__ospf_options__transit_delay(34)
internetProfile__telco_options__expect_callback(99)
internetProfile__telco_options__dialout_allowed(100)
internetProfile__telco_options__delay_callback(101)
internetProfile__ppp_options__send_auth_mode(102)
internetProfile__ppp_options__send_password(103)
internetProfile__ppp_options__substitute_send_name(104)
internetProfile__ppp_options__recv_password(105)
internetProfile__ppp_options__link_compression(106)
internetProfile__ppp_options__mru(107)
internetProfile__ppp_options__lqm(108)
internetProfile__ppp_options__lqm_minimum_period(109)
internetProfile__ppp_options__lqm_maximum_period(110)
internetProfile__ppp_options__cbcp_enabled(111)
internetProfile__ppp_options__mode_callback_control(112)
internetProfile__ppp_options__delay_callback_control(113)
internetProfile__ppp_options__trunk_group_callback_control(114
internetProfile__ppp_options__split_code_dot_user_enabled(115
internetProfile__ppp_options__ppp_interface_type(116) internetProfile__mp_options__base_channel_count(117)
internetProfile__mp_options__minimum_channels(118)
internetProfile__ipx_options__net_number(53)
internetProfile__mp_options__maximum_channels(119)
internetProfile__ipx_options__net_alias(54)
internetProfile__mp_options__bacp_enable(120)
internetProfile__ipx_options__sap_filter(55)
internetProfile__mpp_options__aux_send_password(121)
internetProfile__ipx_options__ipx_spoofing(56)
internetProfile__mpp_options__dynamic_algorithm(122)
internetProfile__ipx_options__spoofing_timeout(57)
internetProfile__mpp_options__bandwidth_monitor_direction(123
internetProfile__ipx_options__ipx_sap_hs_proxy(58)
internetProfile__mpp_options__increment_channel_count(124)
internetProfile__ipx_options__ipx_header_compression(59)
internetProfile__mpp_options__decrement_channel_count(125) internetProfile__bridging_options__bridging_group(60)
internetProfile__mpp_options__seconds_history(126)
internetProfile__bridging_options__dial_on_broadcast(61)
internetProfile__mpp_options__add_persistence(127)
internetProfile__bridging_options__ipx_spoofing(62)
internetProfile__mpp_options__sub_persistence(128)
internetProfile__bridging_options__spoofing_timeout(63)
internetProfile__mpp_options__target_utilization(129)
internetProfile__bridging_options__bridge_type(64)
6-42 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
Ascend MIB hierarchy
internetProfile__fr_options__frame_relay_profile(130)
internetProfile__fr_options__dlci(131)
internetProfile__fr_options__circuit_name(132)
internetProfile__fr_options__fr_direct_enabled(133)
internetProfile__calledNumber(189)
internetProfile__dhcp_options__reply_enabled(190)
internetProfile__dhcp_options__pool_number(191)
internetProfile__dhcp_options__maximum_leases(192)
internetProfile__fr_options__fr_direct_profile(134)
internetProfile__fr_options__fr_direct_dlci(135)
internetProfile__sharedprof_options(193) internetProfile__t3pos_options__x25_profile(194) internetProfile__tcp_clear_options__detect_end_of_packet(136) internetProfile__t3pos_options__max_calls(195) internetProfile__tcp_clear_options__end_of_packet_pattern(137) internetProfile__t3pos_options__auto_call_x121_address(196)
internetProfile__tcp_clear_options__flush_length(138)
internetProfile__tcp_clear_options__flush_time(139)
internetProfile__ara_options__recv_password(140)
internetProfile__ara_options__maximum_connect_time(141)
internetProfile__comb_options__password_required(142)
internetProfile__comb_options__interval(143)
internetProfile__comb_options__base_channel_count(144)
internetProfile__comb_options__compression(145)
internetProfile__x25_options__x25_profile(146)
internetProfile__x25_options__lcn(147)
internetProfile__x25_options__x3_profile(148)
internetProfile__x25_options__max_calls(149)
internetProfile__x25_options__vc_timer_enable(150)
internetProfile__x25_options__x25EncapsType(151)
internetProfile__x25_options__auto_call_x121_address(152)
internetProfile__x25_options__reverse_charge(153)
internetProfile__t3pos_options__reverse_charge(197)
internetProfile__t3pos_options__answer(198)
internetProfile__t3pos_options__t3PosHostInitMode(199)
internetProfile__t3pos_options__t3PosDteInitMode(200)
internetProfile__t3pos_options__t3PosEnqHandling(201)
internetProfile__t3pos_options__t3PosMaxBlockSize(202) internetProfile__t3pos_options__t3PosT1(203)
internetProfile__t3pos_options__t3PosT2(204)
internetProfile__t3pos_options__t3PosT3(205)
internetProfile__t3pos_options__t3PosT4(206)
internetProfile__t3pos_options__t3PosT5(207)
internetProfile__t3pos_options__t3PosT6(208)
internetProfile__t3pos_options__t3PosMethodOfHostNotif(209)
internetProfile__t3pos_options__t3PosPidSelection(210)
internetProfile__t3pos_options__t3PosAckSuppression(211)
internetProfile__t3pos_options__x25_rpoa(212)
internetProfile__x25_options__call_mode(154)
internetProfile__x25_options__answer(155)
internetProfile__x25_options__inactivity_timer(156)
internetProfile__x25_options__if_mtu(157)
internetProfile__x25_options__x25_rpoa(158)
internetProfile__x25_options__x25_cug_index(159)
internetProfile__x25_options__x25_nui(160)
internetProfile__x25_options__pad_banner(161)
internetProfile__x25_options__pad_prompt(162)
internetProfile__x25_options__pad_nui_prompt(163)
internetProfile__x25_options__pad_nui_pw_prompt(164)
internetProfile__x25_options__pad_alias1(165)
internetProfile__x25_options__pad_alias2(166)
internetProfile__x25_options__pad_alias3(167)
internetProfile__x25_options__pad_diag_disp(168)
internetProfile__x25_options__pad_default_listen(169)
internetProfile__t3pos_options__x25_cug_index(213)
internetProfile__t3pos_options__x25_nui(214)
internetProfile__t3pos_options__data_format(215)
internetProfile__t3pos_options__link_access_type(216)
internetProfile__framed_only(217)
internetProfile__altdial_number1(218)
internetProfile__altdial_number2(219)
internetProfile__altdial_number3(220)
internetProfile__x32_options__x32_profile(221)
internetProfile__x32_options__call_mode(222)
internetProfile__tunnel_options__profile_type(223)
internetProfile__tunnel_options__tunneling_protocol(224)
internetProfile__tunnel_options__max_tunnels(225)
internetProfile__tunnel_options__atmp_ha_rip(226)
internetProfile__tunnel_options__primary_tunnel_server(227)
internetProfile__tunnel_options__secondary_tunnel_server(228)
internetProfile__x25_options__pad_default_pw(170)
internetProfile__eu_options__dce_addr(171)
internetProfile__eu_options__dte_addr(172)
internetProfile__eu_options__mru(173)
internetProfile__x75_options__k_frames_outstanding(174)
internetProfile__x75_options__n2_retransmissions(175)
internetProfile__x75_options__t1_retran_timer(176)
internetProfile__x75_options__frame_length(177)
internetProfile__tunnel_options__udp_port(229)
internetProfile__tunnel_options__password(230)
internetProfile__tunnel_options__home_network_name(231)
internetProfile__tunnel_options__unused(232)
internetProfile__pri_numbering_plan_id(233)
internetProfile__vrouter(234)
internetProfile__atm_options__atm1483type(235)
internetProfile__atm_options__vpi(236)
internetProfile__appletalk_options__atalk_routing_enabled(178) internetProfile__atm_options__vci(237) internetProfile__appletalk_options__atalk_static_ZoneName(179) internetProfile__action__(238)
internetProfile__appletalk_options__atalk_static_NetStart(180)
internetProfile__appletalk_options__atalk_static_NetEnd(181)
internetProfile__appletalk_options__atalk_Peer_Mode(182)
internetProfile__usrRad_options__acct_type(183)
internetProfile__usrRad_options__acct_host(184)
internetProfile__usrRad_options__acct_port(185)
internetProfile__usrRad_options__acct_key(186)
internetProfile__usrRad_options__acct_timeout(187)
internetProfile__usrRad_options__acct_id_base(188) mibinternetProfile__tcp_clear_options__portTable (2)
internetProfile__tcp_clear_options__port__station (1)
internetProfile__tcp_clear_options__port__index__ (2)
internetProfile__tcp_clear_options__port (3) mibinternetProfile__tcp_clear_options__hostTable (3)
internetProfile__tcp_clear_options__host__station (1)
internetProfile__tcp_clear_options__host__index__ (2)
internetProfile__tcp_clear_options__host (3) mibinternetProfile__ipx_options__ipx_sap_hs_proxy_netTable (4)
internetProfile__ipx_options__ipx_sap_hs_proxy_net__station (1)
internetProfile__ipx_options__ipx_sap_hs_proxy_net__index__ (2
internetProfile__ipx_options__ipx_sap_hs_proxy_net (3)
APX 8000/MAX TNT/DSLTNT Administration Guide 6-43
SNMP Administration
Ascend MIB hierarchy
mibframeRelayProfile (2)
The mibframeRelayProfile
has the value:
1.3.6.1.4.1.529.23.2
The mibframeRelayProfile
in the configuration
group contains the following objects:
mibframeRelayProfileTable (1) mibframeRelayProfileEntry (1)
frameRelayProfile__fr_name (1)
frameRelayProfile__active (2)
frameRelayProfile__nailed_up_group (3)
frameRelayProfile__nailed_mode (4)
frameRelayProfile__called_number_type (5)
frameRelayProfile__switched_call_type (6)
frameRelayProfile__phone_number (7)
frameRelayProfile__billing_number (8)
frameRelayProfile__transit_number (9)
frameRelayProfile__link_mgmt (10)
frameRelayProfile__call_by_call_id (11)
frameRelayProfile__link_type (12)
frameRelayProfile__n391_val (13)
frameRelayProfile__n392_val (14)
frameRelayProfile__n393_val (15)
frameRelayProfile__t391_val (16)
frameRelayProfile__t392_val (17) frameRelayProfile__MRU (18)
frameRelayProfile__dceN392_val (19)
frameRelayProfile__dceN393_val (20)
frameRelayProfile__link_mgmt_dlci (21)
frameRelayProfile__action (22)
6-44 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
Ascend MIB hierarchy
mibanswerProfile (3)
The mibAnswerProfile
has the value:
1.3.6.1.4.1.529.23.3
The mibanswerProfile
in the configuration
group contains the following objects:
mibanswerProfileTable (1) mibanswerProfileEntry (1)
answerProfile__index (1)
answerProfile__use_answer_for_all_defaults (2)
answerProfile__force_56kbps (3)
answerProfile__profiles_required (4)
answerProfile__clid_auth_mode (5)
answerProfile__ppp_answer__enabled (6)
answerProfile__ppp_answer__receive_auth_mode (7)
answerProfile__ppp_answer__disconnect_on_auth_timeout (8)
answerProfile__ppp_answer__bridging_group (9)
answerProfile__ppp_answer__link_compression (10)
answerProfile__ppp_answer__mru (11)
answerProfile__ppp_answer__lqm (12)
answerProfile__ppp_answer__lqm_minimum_period (13)
answerProfile__ppp_answer__lqm_maximum_period (14)
answerProfile__mp_answer__enabled (15)
answerProfile__mp_answer__minimum_channels (16)
answerProfile__mp_answer__maximum_channels (17)
answerProfile__mp_answer__bacp_enable (18)
answerProfile__mpp_answer__enabled (19)
answerProfile__mpp_answer__dynamic_algorithm (20)
answerProfile__mpp_answer__bandwidth_monitor_direction (21)
answerProfile__mpp_answer__increment_channel_count (22)
answerProfile__mpp_answer__decrement_channel_count (23)
answerProfile__mpp_answer__seconds_history (24)
answerProfile__mpp_answer__add_persistence (25)
answerProfile__mpp_answer__sub_persistence (26)
answerProfile__mpp_answer__target_utilization (27)
answerProfile__fr_answer__enabled (28)
answerProfile__tcp_clear_answer__enabled (29)
answerProfile__ara_answer__enabled (30)
answerProfile__v120_answer__enabled (31)
answerProfile__v120_answer__frame_length (32) answerProfile__x25_answer__enabled (33)
answerProfile__x25_answer__x25_profile (34)
answerProfile__x25_answer__x3_profile (35)
answerProfile__x25_answer__max_calls (36)
answerProfile__x25_answer__vc_timer_enable (37)
answerProfile__x25_answer__auto_call_x121_address (38)
answerProfile__x25_answer__reverse_charge (39)
answerProfile__x25_answer__x3_custom_prof (40) answerProfile__comb_answer__enabled (41)
answerProfile__comb_answer__password_required (42)
answerProfile__comb_answer__interval (43)
answerProfile__comb_answer__compression (44)
answerProfile__eu_answer__euraw_enabled (45)
answerProfile__eu_answer__euui_enabled (46)
answerProfile__eu_answer__dce_addr (47)
answerProfile__eu_answer__dte_addr (48)
answerProfile__eu_answer__mru (49)
answerProfile__ip_answer__enabled (50)
answerProfile__ip_answer__vj_header_prediction (51)
answerProfile__ip_answer__assign_address (52)
answerProfile__ip_answer__routing_metric (53)
answerProfile__ipx_answer__enabled (54)
answerProfile__ipx_answer__peer_mode (55)
answerProfile__session_info__call_filter (56)
answerProfile__session_info__data_filter (57)
answerProfile__session_info__filter_persistence (58)
answerProfile__session_info__idle_timer (59)
answerProfile__session_info__ts_idle_mode (60)
answerProfile__session_info__ts_idle_timer (61)
answerProfile__session_info__max_call_duration (62)
answerProfile__x75_answer__enabled (63)
answerProfile__x75_answer__k_frames_outstanding (64) answerProfile__x75_answer__n2_retransmissions (65)
answerProfile__x75_answer__t1_retran_timer (66)
answerProfile__x75_answer__frame_length (67)
answerProfile__framed_only (68)
answerProfile__action (69)
APX 8000/MAX TNT/DSLTNT Administration Guide 6-45
SNMP Administration
Ascend MIB hierarchy
mibuds3NetworkProfile (5)
The mibuds3Profile
has the value:
1.3.6.1.4.1.529.23.5
The mibuds3NetworkProfile
in the configuration
group contains the following objects:
mibuds3NetworkProfileTable (1) mibuds3NetworkProfileEntry (1)
uds3NetworkProfile__shelf (1)
uds3NetworkProfile__slot (2)
uds3NetworkProfile__item (3)
uds3NetworkProfile__name (4)
uds3NetworkProfile__physical_address__shelf (5)
uds3NetworkProfile__physical_address__slot (6)
uds3NetworkProfile__physical_address__item_number (7)
uds3NetworkProfile__enabled (8)
uds3NetworkProfile__profile_number (9)
uds3NetworkProfile__line_config__trunk_group (10)
uds3NetworkProfile__line_config__nailed_group (11) uds3NetworkProfile__line_config__route_port__slot_number__slot_number (12) uds3NetworkProfile__line_config__route_port__slot_number__shelf_number (13) uds3NetworkProfile__line_config__route_port__relative_port_number__relative_port_number (14)
uds3NetworkProfile__line_config__activation (15)
uds3NetworkProfile__line_config__call_route_info__shelf (16)
uds3NetworkProfile__line_config__call_route_info__slot (17)
uds3NetworkProfile__line_config__call_route_info__item_number (18)
uds3NetworkProfile__line_config__line_type (19)
uds3NetworkProfile__line_config__line_coding (20)
uds3NetworkProfile__line_config__loopback (21)
uds3NetworkProfile__action (22)
6-46 APX 8000/MAX TNT/DSLTNT Administration Guide
SNMP Administration
Ascend MIB hierarchy
atmpGroup (24)
The atmpGroup
group is defined as: atmpGroup ::= { enterprise ascend 24 }
with this value:
1.3.6.1.4.1.529.24
It contains the following objects:
atmpAgentMode (1) atmpAgentType (2) atmpAgentUDPPort (3) atmpAgentGreMtu (4) atmpAgentForceFragmentation (5) atmpAgentHAIdleLimit (6) atmpLastErrorGenerated (7) atmpAgentSentErrorTo (8) atmpLastErrorRecv (9) atmpAgentRecvErrorFrom (10) atmpEnableAtmpTraps (11) atmpAgentNumberFATunnels (12) atmpAgentNumberHATunnels (13) atmpAgentNumberLocalTunnels (14) atmpAgentTunnelHighWater (15) atmpTunnelTable (16) atmpTunnelEntry (1)
atmpTunnelIndex (1)
atmpTunnelId (2)
atmpHAIpAddress (3)
atmpFAIpAddress (4)
atmpTunneledProtocol (5)
atmpTunnelType (6)
atmpTunnelState (7)
atmpMnIpAddress (8)
atmpMnNetmask (9)
atmpMnIpxNetAddress (10)
atmpMnIpxNodeAddress (11) atmpHNProfileName (12)
atmpHNMaxTunnels (13)
atmpFAPrimaryHAAddress (14)
atmpFASecondaryHAAddress (15)
atmpFASsnStatusIndex (16)
atmpFAUserName (17)
atmpInPkts (18)
atmpInOctets (19)
atmpInErrPkts (20)
atmpOutOctets (22)
atmpOutErrPkts (23)
atmpPktsForcedToFragment (24)
atmpPktsFailedFragment (25)
APX 8000/MAX TNT/DSLTNT Administration Guide 6-47
Using Administrative Profiles
7
The TAOS unit provides a number of profiles that either monitor administration information or enable the administrator to change the state of a slot, line, or device. (For discussion of profiles not directly related to system administration, for example, profiles related to configuring lines, connections, or calls, see the APX 8000/MAX TNT/DSLTNT WAN, Routing, and Tunneling
Configuration Guide or the hardware installation guide for your unit.)
Following are the TAOS unit’s administrative profiles:
Profile
Admin-State-Perm-If
Admin-State-Phys-If
Base
Call-Info
Device-State
DS3-ATM-Stat
Error
LAN-Modem
Log
Description
SNMP Permanent Interface Admin State
SNMP Physical Interface Admin State
System version and enabled features
Active call information
Device Operational State
DS3-ATM status
Fatal Error Log
LAN modem disable state
System event logging configuration
APX 8000/MAX TNT/DSLTNT Administration Guide 7-1
Using Administrative Profiles
How the TAOS unit creates administrative profiles
Profile
Slot-Info
Slot-State
Slot-Type
SNMP
System
T1-Stat
T3-Stat
Timedate
Trap
User
Description
Slot information
Slot Operational State
Slot Type profile
SNMP profiles
System-level parameters
T1 and E1 line status
T3 line status
Current system time and date
SNMP trap destinations
Administrative user accounts
For information about the parameters contained within each of these profiles, see the APX
8000/MAX TNT/DSLTNT Reference.
An administrative profile uses the same set of commands as does any configuration profile in the TAOS unit. For example: admin> read t1-stat { 1 5 1}
T1-STAT/{ shelf-1 slot-5 1 } read admin> list physical-address* = { shelf-1 slot-5 1 } line-state = active channel-state = [ nailed-up nailed-up nailed-up nailed-up nailed-up nailed-up n+ error-count=[0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ] loss-of-carrier = False loss-of-sync = False ais-receive = False yellow-receive = False ber-receive = False carrier-established = True network-loopback = False
How the TAOS unit creates administrative profiles
The TAOS unit allocates SNMP interfaces when a card comes up for the first time. For example, the initial installation of a T1 card creates eight SNMP interfaces, one for each T1 line. Admin-State profiles are stored in NVRAM to keep state information over system resets, so a physical device keeps the same SNMP interface number across system reset or power failures.
Each physical interface in the system has an associated Admin-State-Phys-If profile and each nailed connection, such as a Frame Relay connection or a nailed PPP connection, has an
7-2 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Administrative Profiles
Using the Telnet Access Control List (TACL) profile
associated Admin-State-Perm-If profile. These profiles store the object’s desired state and
SNMP interface number.
At system startup, the TAOS unit reads the Admin-State profiles. If the addressed device is not present in the system and has been replaced by a device of another type, the TAOS unit deletes that profile and creates a new one, with a new SNMP interface number. The next time the system is reset or power cycles, the old device’s SNMP interface number becomes available for reassignment. This means that pulling a slot card does not free up interface numbers. When you reinstall the slot card, the same interface number is assigned. Also, pulling a slot card and replacing it with a slot card of another type does not free up the old interface numbers until the next power cycle or system reset.
For example, each T1 line has an Admin-State-Phys-If profile, and each of the 48 modems on a modem card has a profile. To read the Admin-State-Phys-If profile for the first T1 line in Slot
2, use the Read and List commands, as in the following example: admin>read admin-state-phys-if {1 2 1}
ADMIN-STATE-PHYS-IF/{ shelf-1 slot-2 1 } read admin>list
[in ADMIN-STATE-PHYS-IF/{ shelf-1 slot-2 1 }] device-address* = { shelf-1 slot-2 1 } slot-type = 8t1-card snmp-interface = 34 modem-table-index = 0 desired-state = admin-state-up desired-trap-state = trap-state-enabled
Using the Telnet Access Control List (TACL) profile
To enable you to permit Telnet access to the TAOS unit only from specific IP addresses, the
TAOS system supports a new Telnet Access Control List (TACL) profile. You must have
System authorization to create, read, or modify the profile.
You can configure up to 20 entries in the TACL profile. Each entry can specify a host address
(with a /32 subnet mask) or a subnet address. Specifying a subnet address allows access from any of the addresses in the subnet range.
The TACL profile contains the following parameters, shown here with default values:
[in TACL] enable-permit = no
[in TACL:permit-list[1]] valid-entry = no source-address = 0.0.0.0/0 source-address-mask = 0.0.0.0
APX 8000/MAX TNT/DSLTNT Administration Guide 7-3
Using Administrative Profiles
Using the Admin-State-Perm-If profile
Parameter
Enable-Permit
Valid-Entry
Source-Address
Source-Address-Mask
Specifies
Enable/disable control over Telnet access to the unit on the basis of the Permit-List settings in the TACL profile. If set to no
(the default), the Permit-List settings have no effect. If set to yes
, only the IP addresses specified in the Permit-Lists are allowed to telnet into the TAOS command-line interface. Setting Enable-Permit to yes
has no effect if no Permit-Lists have been specified.
Enable/disable the Permit-List entry.
Source IP address of a host or subnet to be allowed Telnet access to the TAOS unit. The specified subnet mask determines whether the entry is valid for a single host or a subnet. If you specify the subnet mask as part of the Source-Address value, the
Source-Address-Mask value is set automatically to the corresponding dotted decimal value.
The subnet mask to be applied to the Source-Address value before enabling a host Telnet access to the unit. You can set the value directly in dotted decimal format or by including a subnet as part of the Source-Address value.
For example, the following commands create a TACL profile that enables Telnet access from
30 host addresses from 10.27.34.1 to 10.27.34.31: admin> new tacl
TACL read admin> set enable-permit = yes admin> set permit-list 1 valid-entry = yes admin> set permit-list 1 source-address-mask = 10.27.34.1/27 admin> list permit-list 1
[in TACL:permit-list[1] (changed)] valid-entry = yes source-address = 10.27.34.1/27 source-address-mask = 255.255.255.224
admin> write
TACL written
Using the Admin-State-Perm-If profile
The Admin-State-Perm-If profile holds information about the TAOS unit’s nailed interfaces.
The system creates a profile for an active nailed interface and assigns it an interface index. For example: admin> dir admin-state-perm
21 08/28/1998 13:21:37 frswan1
21 08/28/1998 13:21:37 frswan6
27 08/28/1998 13:22:11 radius-frt1.1
30 09/02/1998 15:38:07 apx-e1-ds3a-uds3
30 09/02/1998 17:31:42 apx-e1-ds3a-ds3a
7-4 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Administrative Profiles
Using the Admin-State-Phys-If profile
The Admin-State-Perm-If profile contains the following parameters (shown here with sample values):
[in ADMIN-STATE-PERM-IF/frswan1] station* = frswan1 snmp-interface = 19 desired-state = admin-state-up desired-trap-state = trap-state-enabled inet-profile-type = 1
Parameter
Station
SNMP-Interface
Desired-State
Desired-Trap-Sate
Inet-Profile-Type
Specifies
Name of a nailed profile (PPP or Frame Relay), which may be a local Connection profile or a RADIUS profile.
Interface table index assigned to the nailed interface whose state is stored in this profile.The system assigns a numeric value.
Desired administrative state of the addressed device. The system sets it to Admin-State-Down if an operator downs the device, or to
Admin-State-Up if an operator attempts to bring up the device in normal operations mode. An operator can change the admin state by using SNMP SET commands, or the Slot or If-Admin commands.
Desired link up/down enable state of the interface.The system sets it to Trap-State-Enabled if an operator specifies that linkUp/linkDown traps should be generated for the interface, or to
Trap-State-Disabled if an operator specifies that linkUp/linkDown traps should not be generated for the interface.
If the nailed profile is a local profile (0) or a RADIUS profile (1).
Using the Admin-State-Phys-If profile
The Admin-State-Phys-If profile holds information about the system’s physical interfaces. For example: admin> dir admin-state-phys
17 08/06/1998 17:03:57 { shelf-1 slot-13 1 }
17 08/06/1998 17:03:57 { shelf-1 slot-13 2 }
17 08/06/1998 17:03:57 { shelf-1 slot-13 3 }
17 08/06/1998 17:03:57 { shelf-1 slot-13 4 }
17 08/06/1998 17:03:57 { shelf-1 slot-13 5 }
17 08/06/1998 17:03:57 { shelf-1 slot-13 6 }
APX 8000/MAX TNT/DSLTNT Administration Guide 7-5
Using Administrative Profiles
Using the Device-State profile
The system creates a profile for each of its physical interfaces. The Admin-State-Phys-If profile contains the following parameters (shown here with sample values):
[in ADMIN-STATE-PHYS-IF/{ shelf-1 slot-13 1 }] device-address* = { shelf-1 slot-13 1 } slot-type = hdlc2-card snmp-interface = 0 modem-table-index = 0 desired-state = admin-state-up desired-trap-state = trap-state-enabled
Parameter
Device-Address
Slot-Type
SNMP-Interface
Modem-Table-Index
Desired-State
Desired-Trap-Sate
Specifies
Physical slot address within the system.
Type of card at that address.
Interface table index assigned to the device whose state is stored in this profile.The system assigns a numeric value, which does not change as long as the interface is present in the system. If the card is removed and its profiles deleted (for example, by using a Slot –r command), the index number is freed for future use.
Modem table index assigned to the device whose state is stored in this profile. The system assigns a numeric value. The value is 0 for devices that are not modems.
Desired administrative state of the addressed device. The system sets it to Admin-State-Down if an operator downs the device, or to
Admin-State-Up if an operator attempts to bring up the device in normal operations mode. An operator can change the admin state by using SNMP SET commands, or the Slot or If-Admin commands.
Desired link up/down enable state of the interface.The system sets it to Trap-State-Enabled if an operator specifies that linkUp/linkDown traps should be generated for the interface, or to
Trap-State-Disabled if an operator specifies that linkUp/linkDown traps should not be generated for the interface.
Using the Device-State profile
Every host interface or network interface (such as a T1 or E1 channel) on the TAOS unit has a
Device-State profile, which stores the current state of the device and allows you to change it.
For example, each eight port T1 card has 192 Device-State profiles (one for each T1 channel).
Similarly, each modem card has 48 Device-State profiles (one for each modem).
To open one of the profiles, proceed as in the following example: admin> read device {{1 3 1} 24}
DEVICE-STATE/{ { shelf-1 slot-3 1 } 24 } read admin> list device-address* = { { shelf-1 slot-3 1 } 24 } device-state = down-dev-state
7-6 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Administrative Profiles
Using the Device-Summary profile
up-status = idle-up-status reqd-state = up-reqd-state
In the output, the Device-State parameter shows the current operational state of the device, which can be down, up, or none. (None indicates that the device does not exist.)
The Up-Status parameter is ignored unless the device is up (Device-State=Up-Dev-State). If the device is up, Up-Status shows the status of the device, which can be idle, reserved (will not be used until all idle devices of the same type are in use), or assigned (in use).
The Reqd-State parameter indicates the required operational state of the device, which can be up or down. Changing this value initiates a state change for the device. The change is complete when Device-State changes to match Reqd-State. This setting is not persistent across system resets or power cycles. At system startup, the TAOS unit reinitializes the required state to match the actual state of the card.
Using the Device-Summary profile
The read-only Device-Summary profiles record the status and availability of the modem and
HDLC resources on the TAOS unit. This profile is not stored in NVRAM, so it is not persistent across system resets or power cycles.
To view the modem resources on a TAOS unit, proceed in the following example: admin>
read device-summary modem
DEVICE-SUMMARY/modem read admin>
list
[in DEVICE-SUMMARY/modem] device-class* = modem total-count = 48 operational-count = 48 disabled-count = 0
The parameters in the Device-Summary profiles are described below:
Parameter
Device-Class
Total-Count
Operational-Count
Disabed-Count
Description
The type of device. Values can be any of the following:
• Modem
• Unknown
Total number of devices in the specified class.
Total number of devices in the specified class that are in the Up operational and Up administrative states.
Total number of devices in the specified class that are in the Down operational or Down administrative state.
APX 8000/MAX TNT/DSLTNT Administration Guide 7-7
Using Administrative Profiles
Using the Slot-Info profile
Using the Slot-Info profile
The read-only Slot-Info profile stores information about each slot card that has successfully booted. This profile is not stored in NVRAM, so it is not persistent across system resets or power cycles. It is created when the slot card boots, and is deleted when the slot card is removed or when the TAOS unit’s system is rebooted. It can be read by SNMP managers.
To view the Slot-Info profile, read and list its contents, as in the following example: admin> read slot-info {1 1 0}
SLOT-INFO/{ shelf-1 slot-1 0 } read admin> list
[in SLOT-INFO/{ shelf-1 slot-1 0 }] slot-address* = { shelf-1 slot-1 0 } serial-number = 7470634 software-version = 7.0
software-revision = 4 software-level = b hardware-level = 0 software-release = 1
For information about the parameters in the Slot-Info profiles, see the APX 8000/MAX
TNT/DSLTNT Reference .
Using Slot-State profiles
When you set the required operational state of a slot, the TAOS unit initiates a state change. In terms of settings, Current-State changes to match Reqd-State. This setting is not persistent across system resets or power cycles. At system startup, the TAOS unit reinitializes the required state to match the actual state of the card.
To read a Slot-State profile and display its contents, proceed as in the following example: admin> read slot-state {1 1 0}
SLOT-STATE/{ shelf-1 slot-1 1 } read admin> list slot-address* = { shelf-1 slot-1 0 } current-state = oper-state-down reqd-state = reqd-state-up
The slot address is the physical address of the slot, and cannot be set directly. The
Current-State value shows the current operational state of the slot, and can be any of the states described below.
State
Oper-State-Down
Oper-State-Up
Oper-State-Diag
Oper-State-Dump
Description
The slot is in a nonoperational state.
The slot is in normal operations mode.
The slot is in diagnostics mode.
The slot is dumping core.
7-8 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Administrative Profiles
Using DS3-ATM-Stat profiles
State
Oper-State-Pend
Oper-State-Post
Oper-State-None
Description
The slot is no longer down, but is not yet ready for normal operation. This value denotes a transitional state in which additional shelf-to-slot communications are required to make the slot fully operational.
The slot is running a self-test.
The slot is empty.
The Reqd-State parameter indicates the required operational state of the slot, which can be up or down. Changing this value initiates a state change for the device. To use the Slot-State profile to change slot states, proceed as in the following example.
To bring a slot down: admin> read slot-state {1 3 6}
SLOT-STATE/{ shelf-1 slot-3 6 } read admin> set reqd-state = reqd-state-down admin> write
SLOT-STATE/{shelf-1 slot-3 6} written
To bring the slot back up: admin> set reqd-state = reqd-state-up admin> write
SLOT-STATE/{ shelf-1 slot-3 6} written
Using DS3-ATM-Stat profiles
To display the status of the DS3-ATM line, read and list the DS3-ATM-Stat profile, as in the following example: admin> read ds3-atm-stat {1 7 1}
DS3-ATM-STAT/{ shelf-1 slot-7 1 } read admin> list physical-address*={shelf-1 slot-7 1 } line-state = active f-bit-error-count = 0 p-bit-error-count = 0 cp-bit-error-count = 0 feb-error-count = 0 bpv-error-count = 0 loss-of-signal = False loss-of-frame = False yellow-receive = False ais-receive = False
APX 8000/MAX TNT/DSLTNT Administration Guide 7-9
Using Administrative Profiles
Using T1-Stat profiles
The Line-State parameter shows the overall state of the line which can be any of the following:
State
Does-Not-Exist
Disabled
Loss-of-Signal
Loss-of-Frame
Yellow-Alarm
AIS-Receive
Active
Description
Link is not physically on board.
Line disabled.
Near end has lost signal.
Near end has lost frame.
Receiving yellow-alarm from far end.
Receiving alarm indication signal
Multipoint established.
The remaining parameters indicate the errors on the DS3 line. (Refer to RFC 1407 for complete description of these errors.)
Parameter
F-Bit-Error-Count
P-Bit-Error-Count
CP-Bit-Error-Count
FEB-Error-Count
BPV-Error-Count
Loss-of-Signal
Loss-of-Frame
Yellow-Receive
AIS-Receive
Description
Framing bit errors received since the last TAOS unit reset.
P-bit errors indicate that TAOS unit received a P-bit code on the DS3 M-frame that differs from the locally calculated code.
For C-Bit-Parity lines indicates that number of parity errors since the last TAOS unit reset.
Far end block errors received since the last TAOS unit reset.
Bipolar Violation (BPV) errors may indicate that the line sent consecutive one bits with the same polarity. It could also mean that three or more consecutive zeroes were sent or an incorrect polarity.
True indicates a loss of signal. False indicates that the carrier is maintaining a connection.
True indicates a loss of framing. False indicates that the line is up and in frame.
True indicates that the local device has received a Yellow
Alarm indication. False specifies that the local device has not received a Yellow Alarm indication.
True indicates that the local device has received alarm indication signal. False indicates local device has not received and alarm indication signal.
Using T1-Stat profiles
The T1-Stat profile displays the status of the T1 lines and their channels. Each T1 line has a separate profile. When the T3 card is operational, it creates a T3-Stat profile and twenty-eight
T1-Stat profiles, which store the current status of the DS3 and each component DS1.
7-10 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Administrative Profiles
Using UDS3-Stat profiles
To display the status of the T1 line, read and list the T1-Stat profile, as in the following example: admin>
read t1-stat {1 8 1}
T1-STAT/{ shelf-1 slot-8 1 } read admin>
list
physical-address* = { shelf-1 slot-10 7 } line-state = disabled channel-state = [ disabled disabled disabled disabled disabled + error-count = [ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ] loss-of-carrier = False loss-of-sync = False ais-receive = False yellow-receive = False ber-receive = False carrier-established = False network-loopback = False
The Line-State parameter shows the overall state of the line which can be any of the following:
State
Does-Not-Exist
Disabled
Loss-of-Sync
Yellow-Alarm
AIS-Receive
No-D-Channel
Active
Description
Link is not physically on board.
Line disabled.
Red-alarm state, plus or minus.
Yellow-alarm state.
Receiving keep-alive signal
D-Channel failure.
Multipoint established.
The channel-state parameter shows the state of each channel. Possible states are:.
State
Unavailable
Unused
Out-of-service
Nailed-up
Description
Not available.
Not in use.
Out of service.
Nailed.
The Error-Count parameter shows an error count for each channel.
For complete descriptions of the parameters in the T1-Stat profile, see to the APX 8000/MAX
TNT/DSLTNT Reference.
Using UDS3-Stat profiles
To display the status of the UDS3 line, read and list the UDS3-Stat profile, as in the following example:
APX 8000/MAX TNT/DSLTNT Administration Guide 7-11
Using Administrative Profiles
Using UDS3-Stat profiles
admin> read uds3-stat {1 13 1}
UDS3-STAT/{ shelf-1 slot-13 1 } read admin> list line-state = active f-bit-error-count = 0 p-bit-error-count = 0 cp-bit-error-count = 0 feb-error-count = 0 bpv-error-count = 0 loss-of-signal = False loss-of-frame = False yellow-receive = False ais-receive = False
The Line-State parameter shows the overall state of the line which can be any of the following:
State
Does-Not-Exist
Disabled
Loss-of-Signal
Loss-of-Frame
Yellow-Alarm
AIS-Receive
Active
Description
Link is not physically on board.
Line disabled.
Near end has lost signal.
Near end has lost frame (also known as a red alarm).
Receiving yellow-alarm from far end.
Receiving alarm indication signal
Multipoint established.
The remaining parameters indicate the errors on the DS3 line. (Refer to RFC 1407 for complete description of these errors.)
Parameter
F-Bit-Error-Count
P-Bit-Error-Count
CP-Bit-Error-Count
FEB-Error-Count
BPV-Error-Count
Loss-of-Signal
Loss-of-Frame
Description
Framing bit errors received since the last TAOS unit reset.
P-bit errors indicate that TAOS unit received a P-bit code on the DS3 M-frame that differs from the locally calculated code.
For C-Bit-Parity lines indicates that number of parity errors since the last TAOS unit reset.
Far end block errors received since the last TAOS unit reset.
Bipolar Violation (BPV) errors may indicate that the line sent consecutive one bits with the same polarity. It could also mean that three or more consecutive zeroes were sent or an incorrect polarity.
True indicates a loss of signal. False indicates that the carrier is maintaining a connection.
True indicates a loss of framing (also known as a red alarm). False indicates that the line is up and in frame.
7-12 APX 8000/MAX TNT/DSLTNT Administration Guide
Using Administrative Profiles
Using UDS3-Stat profiles
Parameter
Yellow-Receive
AIS-Receive
Description
True indicates that the local device has received a Yellow
Alarm indication. False specifies that the local device has not received a Yellow Alarm indication.
True indicates that the local device has received alarm indication signal. False indicates local device has not received and alarm indication signal.
Using the Call-Logging Server profile
You can control to which server the TAOS unit sends its logging information, provided that the
Call-Logging profile is properly configured and enabled. Following are the relevant parameters, shown with default settings:
[in CALL-LOGGING] call-log-server-index = host-1
Parameter Description
Call-Log-Server-Index Which of the configured call-log-host-
N settings are used as the active call-logging server. Valid values are host-1
(the default), host-2
, and host-3
. If the TAOS unit cannot authenticate the specified server, it attempts to use the next configured server.
To enable you to make this choice from an SNMP management station, the callLoggingCurrentServerFlag in the callLoggingServerEntry , which is in the Ascend call-logging MIB, is a read-write variable. The variable can be set to 1 (active) or 2
(standby). Following is the new definition: callLoggingCurrentServerFlag OBJECT-TYPE
SYNTAX INTEGER {
active(1),
standby(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "Value indicates whether this entry is the current
Call Logging server or not. The standby(2) is not
set-able it is a value to report the standby status
of the Call Logging server."
::= { callLoggingServerEntry 2 }
APX 8000/MAX TNT/DSLTNT Administration Guide 7-13
Getting TAOS Unit Core Dumps
A
What is a core dump?
A TAOS core dump is a snapshot of the TAOS unit’s shelf controller or slot card memory. A
Lucent representative might ask you to obtain a core dump to help diagnose a problem. To get a core dump from the TAOS unit, you must use the Coredump command on the TAOS unit and the Ascendump utility on a local UNIX workstation.
The Coredump command controls how the TAOS unit generates core dumps. Ascendump controls how the TAOS unit core dumps are written to disk. You can specify that the core dump be collected whenever there is a fatal error, or you can get the core dump at any time from the server running Ascendump or from the TAOS unit itself.
The core-dump server can be connected through any LAN or WAN interface, and may be multiple hops away. The only restriction is that the data path from a crashing shelf or card must pass through shelves or cards that are still alive. The only exception is that a crashing shelf can dump through its own Ethernet port, and a crashing Ethernet card can dump through one of its own Ethernet ports.
The TAOS unit uses UDP to write core dumps over the Ethernet.
!
Caution:
Do not use core dumps unless specifically requested to by a Lucent representative.
APX 8000/MAX TNT/DSLTNT Administration Guide
Preliminary May 10, 2000
A-1
Getting TAOS Unit Core Dumps
Before you begin
Before you begin
Before installing and using the Ascendump utility, make sure you:
• Are familiar with the UNIX shell and know how to change directories, get information about files, use FTP, start processes, check available disk space, and so on.
• Have a local UNIX workstation running Solaris, SUNOS, or BSDI UNIX. (To use core dump on other versions of UNIX, contact technical support.)
• Have a minimum of 16Mb free disk space on the core-dump server. Note, however, that more space might be required under certain circumstances, such as if you are core dumping the core from the 32M DRAM card.
• Have downloaded the appropriate version of Ascendump from the Ascend FTP server
( ftp.ascend.com/pub/Utilities/coredump
).
• Have installed it in the directory from which you want to run it, and have used the chmod
+x command to make the file executable.
The Ascendump daemon
Ascendump has the following syntax:
ascendump [-v -r -c -u -p] [-n email-recipient] [-s slot] [-d
directory] [host]
Option
-v
-r
-c
-p
-s slot
-u
-n email-recipient
-d directory
Explanation
accept
Reset the TAOS unit after the core dump. This is the default in daemon mode.
Do not reset the box after the core dump. This is the default in client mode.
Print diagnostics to the terminal screen instead of Syslog.
By default the server mode uses Syslog and the client mode prints to the terminal.
Dump the memory of the card in slot number
slot
.
Network traffic will be forwarded through the shelf controller. In a multishelf system, a slot card can only dump through its own shelf controller.
Store files uncompressed. By default files are compressed with gzip
.
Send an email notification to the specified email recipient.
You can use this option more than once to designate multiple recipients. You can also use mail aliases.
The directory path for writing the core dumps. The default is
/usr/ascendumps
.
host
A-2
Preliminary May 10, 2000
APX 8000/MAX TNT/DSLTNT Administration Guide
Getting TAOS Unit Core Dumps
Coredump command
Coredump command
The Coredump command’s syntax provides the following valid entries:
coredump
coredump enable | local | remote [server ]
coredump disable coredump now coredump trace
Syntax element coredump enable
Description local remote
server
disable now trace
Enables Coredump. If you do not specify a server, the core-dump server remains unchanged.
The most commonly used mode. In Local mode the Ascendump daemon listens for packets from the TAOS unit. The Ascendump daemon operates in server mode, and the TAOS unit core dump facility operates in client mode.
Enables the Ascendump daemon to pull a core dump from the TAOS unit. Remotely initiated core dumps can be a security risk, so they are disabled by default. If you enable remote core dumps, they remain enabled only until the TAOS unit resets. That is, a reset restores the default setting.
The host that has the Ascendump daemon installed.
Disables Coredump.
Forces an immediate core dump to the machine running the
Ascendump daemon. This is useful for testing the core dump process.
Toggles serial debug traces which can be useful to a Lucent representative if a customer is having difficulties.
Core dump naming conventions and file characteristics
The core-dump files use the following naming convention:
hostname-[shelf, slot]-loadname-swversion-YYMMDD-HH:MM.gz where:
•
hostname
is the hostname or IP address of the Ascend unit.
•
shelf,slot
is the shelf and slot number of the card that has dumped its core. (This applies only to the TAOS unit.)
•
loadname
is the name of the software load running on the TAOS unit.
•
swversion
is the version of the software load running on the TAOS unit.
•
yymmdd-hh:mm
is a date and time stamp. Each dump file can be four to eight megabytes in size.
APX 8000/MAX TNT/DSLTNT Administration Guide
Preliminary May 10, 2000
A-3
Getting TAOS Unit Core Dumps
Examples
For example: tnt10.abc.com-1,3-tntmdm56k-1.3Ap22-980101-13:42.gz
When transferring the core-dump files via FTP, use binary mode.
Trigger events
The events that normally trigger a core dump are system or slot-card resets. These usually show up in the fatal error log either as “Fatal Errors” or “Operator Resets.” You cannot specify the types of events that trigger core dumps.
UDP port numbers
The TAOS unit listens for core dumps on the UDP port given by the following formula:
10,000 + (shelf-number *100) + slot-number
For example, for a card on shelf 1, slot 5, the UDP port for the core dump is 10105. For the shelf controller (slot number 17) on shelf 1, the UDP port for the core dump is 10117.
Similarly, the shelf controller on shelf 8 uses UDP port 10817.
Examples
This section uses examples to show how to get core dumps from the TAOS unit.
Enabling Ascendump
To start the Ascendump daemon, proceed as in the following example:
% ./ascendump -v -u -d /usr/ascendumps
This example runs the daemon in verbose mode and will write the core dumps in uncompressed format to
/usr/ascendumps
.
Enabling core dumps on the TAOS unit
In the following example, the TAOS unit writes the core dump to the host at 172.31.4.34 whenever there is a fatal error: admin> coredump local 172.31.4.34 coreDump: Sending arp request...
core dump server is ‘172.31.4.34 ip=[172.31.4.34/16], mac=[00:60:83:7d:15:8f] coredump over UDP is enabled locally only with server
172.31.4.34
A-4
Preliminary May 10, 2000
APX 8000/MAX TNT/DSLTNT Administration Guide
Getting TAOS Unit Core Dumps
Examples
Pulling a core dump from the TAOS unit
In the following example, the TAOS unit enables the Ascendump daemon to solicit a dump from the TAOS unit. The Ascendump daemon is operating in client mode, and the TAOS unit’s core-dump facility is operating in server mode.
admin> coredump remote
Once remote core dumps are enabled on the TAOS unit, an administrator can “pull” a core dump as in the following example:
% ascendump -d /usr/ascendumps tnt10 where
/usr/ascendumps
is the directory on the Ascendump server and tnt10
is the name of the TAOS unit from which to get the core dump.
Initiating an immediate core dump
In the next example, an administrator forces an immediate core dump: admin> coredump now
Getting core dumps from slot cards
You can configure the Ascendump daemon to request a core dump from a particular TAOS unit’s slot. In the following example the modem card in slot 4 of the TAOS named tnt10 will write to the Ascendump server when it crashes:
1
After opening a session with the card, execute Coredump with the remote option: modem-4> coredump remote
2
Start the Ascendump daemon in slot mode:
% ./ascendump -v -u -s 4 -d /usr/ascendump
Disabling core dumps
To disable core dumps on the TAOS : admin> coredump disable coredump over UDP is disabled
Fatal error log and core dumps
The fatal-error log lists the pseudouser coredump
as the responsible user when the master shelf controller resets after a core dump. For example:
OPERATOR RESET: Index: 99 Revision: 1.3Ap8 Shelf 1 (tntsr)
Date: 09/12/1997. Time: 15:52:43
Reset from unknown, user profile coredump.
APX 8000/MAX TNT/DSLTNT Administration Guide
Preliminary May 10, 2000
A-5
Getting TAOS Unit Core Dumps
Troubleshooting core dumps
Troubleshooting core dumps
Take the following steps if you have difficulty setting up the TAOS unit core dumps:
1
If you have previously installed Ascendump in inetd.conf
, temporarily disable it now, by commenting out the Ascendump line, then, logged in as root, send the SIGHUP command to inetd .
2
Change to a writable directory, and enter
ascendump -p -v -d
–
-v
is verbose mode, which prints progress reports as the core dump proceeds, keeps the daemon in the foreground, and handles dumps serially, all of which make debugging easier.
–
-p
prints diagnostics to stderr
instead of through Syslog (whose output on most systems goes to
/var/adm/messages
).
–
-d
puts the dump files in the current directory.
Performing initial tests in this manner saves time by making failures immediately diagnosable.
3
On the TAOS , enable core dumps to the server machine that is running Ascendump.
4
Look for old debug profiles by entering,
dir debug
from the master shelf controller.
The only reason to have a debug profile on a card other than the master shelf controller is to override the settings for the master shelf controller. Unless you want to do that, you should define a single debug profile for the master shelf controller and delete all other debug profiles.
5
Test slot-card dumps by opening a session with a slot card. You should perform a test dump first on the T1 or E1 card, if present, because these cards have smaller memories, and are quick to reboot.
6
From the session on the card, enter
coredump
to check the status of core dump. The resulting output should report that core dump is enabled and that dumps will be directed to
the server you specified in step 3.
7
Force a core dump with the following command:
coredump now
Ascendump should print something like this:
$ ascendump -p -v -d ascendump: Dumping compressed DRAM image to ‘./tnt10.abc.com-1,11tnt8t1-1.3Ae0-971022-11:17.gz’
Section ‘.data’: dumping 2048 pages from address 0x80000000
.......1 Mb.......2 Mb
Occasionally, core dump fails because gzip is not installed or not in the user’s path. If this is the case, you should download gzip-1.2.4.tar.gz
from any GNU FTP mirror site, then compile and install it, or use the -u (uncompressed) option in the Ascendump command line.
If you still have unexplained failures, run tcpdump or snoop or a packet sniffer on the
Ethernet segment attached to the TAOS that is in the route to the dump server. Do the same on the Ethernet segment attached to the dump server in the route to the TAOS .
Coredump uses UDP, so filter UDP packets. If there’s too much UDP traffic, you might want to filter on port-number ranges as well. For information about the UDP port core dump uses,
see “UDP port numbers” on page A-4.
A-6
Preliminary May 10, 2000
APX 8000/MAX TNT/DSLTNT Administration Guide
Getting TAOS Unit Core Dumps
Troubleshooting core dumps
Proceed to testing more cards by opening CLI channels to them and using the coredump now command. Finish by testing Coredump from the master shelf controller.
Once you have established that core dump works, reinstate your inetd.conf
entry, if present, or add one if necessary. Be sure that the entry points to the same Ascendump binary that you just tested.
Here is a sample inetd.conf
entry: ascendump dgram udp nowait root /usr/local/bin/ascendump ascendump -n dump-notify
The
-n dump-notify
argument tells Ascendump to send email to the email alias dumpnotify
whenever a core dump is captured.
APX 8000/MAX TNT/DSLTNT Administration Guide
Preliminary May 10, 2000
A-7
Log Messages on the TAOS Unit
B
The TAOS unit logs fatal and warning error messages to the fatal error log. If the system crashes before creating a log entry, it prints a stack trace to the console serial port.
System-status messages, however, go to the Syslog host (if enabled) and the Status log.
Fatal and warning error messages
Each time the TAOS unit reboots, it logs a fatal error message to the fatal error log. The fatal error log also notes Warnings, which indicate situations that did not cause the TAOS unit to reset. Development engineers use Warnings for troubleshooting purposes. When a Warning occurs, the TAOS unit has detected an error condition and has recovered from it. Available flash space limits the number of entries in the fatal error log, and entries rotate on a First-in,
First-out (FIFO) basis. You can clear the log by using the Clr-History command.
Format of fatal and warning error messages
Fatal and warning messages have the format shown in the following example:
WARNING: Index: 171 Revision: 8.0.2 Slot 9/2 (csm3v)
Date: 12/22/1999. Time: 20:57:59
Location: e0020b54 e006f568 e005d6b8 e005fd90 e005e4dc e00770a8
The first line indicates the type of error (fatal or warning), the index number of the error, the software revision number, the shelf and slot on which the error occurred,
The second line shows the date and time of the error.
The third line displays the top six program counter addresses from the execution stack active at the time of the crash.
APX 8000/MAX TNT/DSLTNT Administration Guide B-1
Log Messages on the TAOS Unit
Definitions of fatal errors
Definitions of fatal errors
Following are definitions, by index number, of the fatal errors that the TAOS unit can report. If you experience a fatal error, contact Lucent Technical Support.
Index
1
2
15
16
17
18
11
12
13
14
19
20
21
6
7
4
5
8
9
10
Definition
Assert invoked during program execution.
An Assert has been placed in the code. This problem can be either hardware related or software related.
Out of memory during memory allocation
This is an out-of-memory condition, sometimes termed a memory leak.
Switch type bad
LIF error
LCD error
ISAC (BRI) timeout
BRI physical layer timeout.
Processor exception
A processor-exception error caused the reset.
Invalid task switch (EXEC)
No mail descriptor (EXEC)
This reset occurs if the TAOS unit tries to allocate a mail message when there are none left. The cause is usually a memory leak.
No mail buffer memory (EXEC)
No task to run (EXEC)
No timer memory (EXEC)
No timer pool (EXEC)
Wait called while in critical section (EXEC)
DSP not responding
DSP protocol error
DSP internal error
DSP loss of sync
DSP unused
DDD not responding
23
24
25
X25 buffer error
X25 init error
X25 stack error
B-2 APX 8000/MAX TNT/DSLTNT Administration Guide
30
31
32
33
Index
27
28
Definition
Memory allocation of zero length
Memory allocation of negative length
The reset was the result of a software loop.
Too large memory copy
Magic sequence missing (MEMCPY)
Wrong magic sequence (MEMCPY)
Bad start address (MEMCPY)
Log Messages on the TAOS Unit
Definitions of fatal errors
37 DRAM card error
Indicates that a DRAM card of unknown size is inserted in the DRAM slot or that the DRAM card failed POST. Applies to the Pipeline 220 only.
This reset is logged immediately before the TAOS unit goes down.
Instead of a standard stack backtrace, the message includes the active security-profile index. 0 (zero) indicates an unknown security profile. On the
TAOS unit, the Default profile is number 1, and the Full Access profile is number
9.
As a complement to entry 99, this entry is logged as the TAOS unit is coming up.
For a normal, manual reset, you should see a fatal error 99 followed by a fatal error 100.
APX 8000/MAX TNT/DSLTNT Administration Guide B-3
Log Messages on the TAOS Unit
Definitions of warning messages
Definitions of warning messages
Warnings are not the results of reset conditions. Most are detected problems from which the
TAOS unit typically recovers fully. Following are the definitions, by index number, of the warnings the TAOS unit can report. Warning messages, by themselves, are not necessarily cause for concern. They are used by development engineers to determine the cause of fatal errors. Contact Lucent technical support if warning messages are accompanied by fatal errors.
Index
101
102
103
104
105
106
107
108
109
110
111
Definition
Buffer already in use
Buffer belongs to wrong pool
Buffer belongs to wrong heap
Buffer not previously allocated
This warning can be logged under different conditions. For example, double freeing of memory and low-memory conditions can both generate a warning 104.
Buffer bad memory allocation
Buffer belongs to bogus pool
Buffer belongs to bogus heap
Memory management code (or other modules) detected that the buffer header of what should have been a free buffer was corrupted by the previous overwrite.
Buffer negative length memory allocation
A negative length request was made to the memory allocation code.
Buffer zero length memory allocation
This warning is similar to Warning 108, except that a zero length request is made to the memory allocation code.
Error in buffer boundary
Error buffer too big
Indicates that a software routine has tried to allocate a block of memory greater than 64Kbytes.
117
118
119
120
113
114
115
116
Error buffer segment count zero
Error buffer trailer magic
Error in buffer trailer
Error in buffer trailer length
Error in buffer trailer user magic
Error buffer write after free
Error buffer not in use
Error buffer magic in memory copy
B-4 APX 8000/MAX TNT/DSLTNT Administration Guide
Log Messages on the TAOS Unit
Definitions of warning messages
176
177
178
179
180
Index
121
130
140
145
150
151
152
153
154
160
161
165
170
171
175
181
182
Definition
Error next buffer magic in memory copy
PPP async buffer in use
Indicates a PPP error.
Error no timers
LCD memory allocation failure
Indicates that a memory-copy routine was called, but the source buffer was much larger than expected.
Error memory copy too large
Error memory copy magic missing
Error memory copy wrong magic
Error memory copy bad start address
WAN buffer leak
Indicates an error in the WAN drivers.
Error in terminal-server state
Indicates an error in the WAN drivers.
Error in terminal server semaphore
Error in telnet free driver
STAC timeout
Indicates a hardware error in the STAC compression chip.
STAC data not owned
Error in the STAC compression chip.
EXEC failure
Indicates that there is insufficient memory to start a new task.
EXEC restricted
EXEC no mailbox
EXEC no resources
Unexpected error
Channel map stuck
Caused by a missing channel on a T1/PRI line.
Channel display stuck
New call without disconnect request
Indicates that a Disconnect message to the Central Office (CO) was not sent. The problem can be caused by conditions on the TAOS unit or at the CO. When the
TAOS unit encounters the condition, it assumes the CO is correct, and answers the call.
APX 8000/MAX TNT/DSLTNT Administration Guide B-5
Log Messages on the TAOS Unit
Fatal crash information on console
Index
303
304
305
306
194
195
301
302
190
191
192
193
183
184
185
186
1001
1002
1003
1006
381
382
383
550
1010
1011
Definition
New call without disconnect response
Disconnect request dropped
Spyder buffer error
Spyder descriptor error
TCP send buffer too big
TCP sequence gap
TCP too much data
TCP write attempt too large
TCP options bad
Modem message parsing failed
TACACS Plus pointer inconsistency
TACACS Plus index inconsistency
TACACS Plus TCP inconsistency
TACACS Plus TCP out-of-range socket
TACACS Plus socket mismatch
TACACS Plus unexpected authentication state
Error in filter list
Error no count in filter list
Error mismatch count filter list
No Ethernet transmit buffer
Waiting for Ethernet controller
Ethernet ACK command failed
Ethernet reset invoked
Ethernet controller unavailable (wait fail)
Bad Ethernet transmit interrupt
Ethernet transmit not completed
Fatal crash information on console
If the TAOS unit crashes without being able to write to the fatal error log, it prints a stack trace to the console serial port at the bit rate defined in the Serial profile. The trace reports the following information:
FE: N, Load: loadname, Version: version
Stack trace: 0xaddr-0 0xaddr-1 0xaddr-2 0xaddr-3 0xaddr-4 0xaddr-5
The first line indicates the number of the error and the software revision number.
B-6 APX 8000/MAX TNT/DSLTNT Administration Guide
Log Messages on the TAOS Unit
Syslog messages
The second line displays the top six program counter addresses from the execution stack active at the time of the crash.
Syslog messages
Syslog offloads to a host computer, known as the Syslog host. The Host parameter in the Log profile specifies the Syslog host, which saves the system status messages in a log file.
See the UNIX man pages about logger(1)
, syslog(3)
, syslog.conf(5)
, and syslogd(8)
for details of the syslog
daemon. The Syslog function requires UDP port
514.
The TAOS unit can report the following session data about various errors logged via Syslog:
Data Description
[shelf/slot/line/channel] Physical channel identifier.
[MBID xxx]
Session identifier.
[name]
[ calling -> called ]
The authenticated name.
The calling number or the called number, or both.
Progress code
Disconnect code
A TAOS unit-specific code indicating the progress of the call. (For a list of progress codes, see the APX
8000/MAX TNT/DSLTNT Reference.)
A TAOS unit-specific code indicating the reason the call was disconnected. (For a list of disconnect codes, see the APX 8000/MAX TNT/DSLTNT Reference.)
For a given session identifier, multiple physical channel identifiers are possible. For example, one identifier might be for a T1 lineThis is shown in the sample log below, in which messages include the MBID, DNIS, and CLID in brackets. In this example, slot 1/2 is an 8T1 card, and slot 1/3 is a 48-modem card.
...: [1/2/1/2] [MBID 1; 9995551212 -> 7898] Incoming Call
...: [1/3/1/0] [MBID 1; 9995551212 -> 7898] Assigned to port
...: [1/2/1/2] [MBID 1; 9995551212 -> 7898] Call Connected
...: [1/3/1/0] [MBID 1] [johnc-pc] LAN session up: <johnc-pc>
...: [1/3/1/0] [MBID 1] [johnc-pc] LAN session down: <johnc-pc>
...: [1/3/1/0] [MBID 1; 9995551212 -> 7898] Call Terminated
...: [1/3/1/0] [MBID 1] [johnc-pc] : STOP: ’johnc-pc’; cause 45.; progress 60.; host 10.1.26.2
APX 8000/MAX TNT/DSLTNT Administration Guide B-7
Log Messages on the TAOS Unit
Syslog messages
End of call information
If the Call-Info parameter is set to End-of-Call, the TAOS unit reports the following information to Syslog at the end of each authenticated call:
• Station name
• Calling phone number
• Called phone number
• Encapsulation protocol
• Data rate (in bits per second)
• Progress code and disconnect reason
• Number of seconds before authentication
• Number of bytes or packets received during authentication
• Number of bytes or packets sent during authentication
• Length of session (in seconds)
• Number of bytes or packets received during the session
• Number of bytes or packets sent during the session
The following example of a Syslog message shows the information it provides about the terminated call:
"Conn=("cjones-p50" 5106785291->? PPP 56000 60/185) \
Auth=(3 347/12 332/13) \
Sess=(1 643/18 644/19), Terminated"
The information also appears in the connection-status window, and is logged as a message at level Info.
If some of the information is not available, that field displays either a question mark (for strings) or a zero (for numerals).
DNIS and CLID information
Syslog messages pertaining to a call display DNIS and CLID information, provided that the information is known. Following is an example that shows the DNIS 7895 in Syslog messages:
LOG info, Shelf 1, Controller, Time: 17:48:56--
† shelf 1, slot 1, line 1, channel 6, dnis 7895, Incoming Call, MBID
001
LOG info, Shelf 1, Controller, Time: 17:48:56--
† shelf 1, slot 2, dnis 7895, Assigned to port, MBID 001
LOG info, Shelf 1, Controller, Time: 17:48:57--
† shelf 1, slot 1, line 1, channel 6, dnis 7895, Call Connected, MBID
001
LOG warning, Shelf 1, Controller, Time: 17:49:20--
† shelf 1, slot 1, line 1, channel 6, dnis 7895, Call Disconnected
LOG info, Shelf 1, Controller, Time: 17:4
9:20--
† shelf 1, slot 2, Call Terminated
B-8 APX 8000/MAX TNT/DSLTNT Administration Guide
Log Messages on the TAOS Unit
Syslog messages
Syslog messages initiated by a Secure Access Firewall
Depending on the settings specified in Secure Access Manager (SAM), the TAOS unit might generate Syslog packets about packets detected by Secure Access Firewall. By default, SAM specifies generation of a Syslog message about every packet blocked by the firewall. All messages initiated by a firewall are in the following format:
date time router name LUCENT: interface message
•
date
is the date the message was logged by syslog.
•
time
is the time the message was logged by syslog.
•
router
is the router this message was sent from.
•
interface
is the name of the interface ( ie0
, wan0
, and so on), unless a call filter logs the packet as it brings up the link, in which case the word call
appears.
• The
message
format has a number of fields, one or more of which may be present.
The message fields appear in the following order:
protocol local direction remote length frag log tag
Table B-1. Syslog message fields for Secure Access Firewalls
Field
protocol local direction remote length frag
Description
Can be the four hexadecimal character Ether Type or one of the following network protocol names: ARP, RARP, IPX, Appletalk. For
IP protocols, the field contains either the IP protocol number (up to 3 decimal digits) or one of the following names: IP-in-IP, TCP, ICMP,
UDP, ESP, AH. In the special case of ICMP, the field also includes the ICMP Code and Type ([Code]/[Type]/icmp).
For non-IP packets, local
is the source Ethernet MAC address of transmitted packets and the destination Ethernet MAC address of received packets. For a nonbridged WAN connection, the two MAC addresses are zeros. For IP protocols,
local is the IP source address of transmitted packets and the IP destination address of received packets. In the case of TCP or UDP, it also includes the TCP or UDP port number ([IP-address];[port]).
An arrow (<- or ->) indicating the direction in which the packet was traveling (receive and send, respectively).
For non-IP protocols, remote has the same format that
local
has non-IP packets, but remote shows the destination Ethernet MAC address of transmitted packets and the source Ethernet MAC address of received packets. For IP protocols, remote has the same format as local but shows the IP destination address of transmitted packets and the IP source address of received packets.
The length of the packet in octets (8-bit bytes).
Indicates that the packet has a nonzero IP offset or that the IP
More-Fragments bit is set in the IP header.
APX 8000/MAX TNT/DSLTNT Administration Guide B-9
Log Messages on the TAOS Unit
Syslog messages
Table B-1. Syslog message fields for Secure Access Firewalls (continued)
Field
log tag
Description
Reports one or more messages based upon the packet status or packet header flags. The packet status messages include:
• corrupt—the packet is internally inconsistent
• unreach—the packet was generated by an “unreach=” rule in the firewall
• !pass—the packet was blocked by the data firewall
• bringup—the packet matches the call firewall
• !bringup—the packet did not match the call firewall
• TCP flag bits that will be displayed include syn, fin, rst.
• syn is will only be displayed for the initial packet which has the
SYN flag and not the ACK flag set. contains any user defined tags specified in the filter template used by
SAM.
The backoff queue error message in the Syslog file
Accounting records are kept until they are acknowledged by the accounting server. Up to 100 unacknowledged records are stored in the backoff queue. If the unit never receives an acknowledgment to an accounting request, it will eventually run out of memory. In order to keep this situation from the occurring, the unit deletes the accounting records and displays this error message in the syslog file:
Backoff Q full, discarding user username
This error generally occurs for one of the following reasons:
• You enabled RADIUS accounting on the TAOS unit, but not on the RADIUS server.
• The Acct-Port or Acct-Key are incorrect. The Acct-Key must match the value assigned in the RADIUS clients file or the TACACS+ configuration file.
• You are using a PortMaster® server rather than a TAOS unit server.
B-10 APX 8000/MAX TNT/DSLTNT Administration Guide
Log Messages on the TAOS Unit
Flash card error messages
Flash card error messages
When a Load, Format, or Dircode command fails, the TAOS unit logs the messages described in this section.
Load command messages
Table B-2 lists the error messages that might appear when using the Load command:
Table B-2. Load command error messages
Error message Description
load: error: flash card write failed: card full
There is no space to load software on the flash card.
load: error: specified flash card not present
No flash card is detected in the specified slot (1 or 2).
load: error: specified flash card not formatted
A Format command is required before loading the software. load: error: specified flash card is write-protected
The flash card’s write-protect switch is set.
load: error: specified flash image is currently in use
A slot card in the LOAD state is currently accessing the flash card.
Format command messages
Table B-3 lists the error messages might appear when using the Format command:
Table B-3. Format command error messages
Error message Description
error: flash card
N
is not present
No flash card is detected in the specified slot (1 or 2).
error: flash card
N
is unavailable The flash card in the specified slot is already being formatted, is just coming up, or is in an error condition.
error: flash card
N
is write-protected
The write-protect switch is set on the card in the specified slot (1 or 2).
error: flash card
N
is currently in use
One or more images on the flash card are being read by a slot card in the
LOAD state or are being written as part of a code download.
APX 8000/MAX TNT/DSLTNT Administration Guide B-11
Log Messages on the TAOS Unit
Flash card error messages
Dircode command messages
Table B-4 lists the error messages might appear when using the Dircode command:
Table B-4. Dircode command error messages
Error message Description
Card
N
is not formatted for use with this system
The flash card is blank, corrupted, or formatted for another environment, such as DOS. To use this card, you must issue a Format command first.
Card
N
is temporarily unavailable The flash card is currently coming up or is being formatted.
Card
N
is unavailable The flash card experienced an error and is inaccessible.Check that the card is inserted properly.
B-12 APX 8000/MAX TNT/DSLTNT Administration Guide
PPP Decoding Primer
C
Many of the diagnostic commands display raw data. This Primer is designed to assist you in decoding PPP, MP, MP+ and BACP negotiations. The negotiations can be logged with the
Diagnostic commands
PPPDump
,
WANDisplay
,
WANDSess
,
WANNext
or
WANOpen
. For more detailed information than this guide provides, refer to the specific RFCs. A partial list of pertinent RFCs appears at the end of this guide.
Breaking down the raw data
An important concept to keep in mind is that each device negotiates PPP independently, so the options might be identical for each direction of the session.
During PPP negotiation, frame formats in the various protocols are very similar. They share the following characteristics:
•
FF 03
indicating it is a PPP frame.
• A two-byte Protocol Identifier.
• A one-byte Packet Format ID number
• A one-byte ID number.
• A two-byte length.
• Options for the protocol.
Below is a table of the most common protocols you’ll see in Lucent diagnostic traces:
Identifier:
C0 21
C0 23
C2 23
80 21
80 29
80 2B
80 31
Description:
Link Control Protocol (LCP)
Password Authentication Protocol (PAP)
Challenge Handshake Authentication Protocol (CHAP)
Internet Protocol (IP)
Appletalk Protocol
Novell’s Internetwork Packet Exchange (IPX)
Bridging PDU
APX 8000/MAX TNT/DSLTNT Administration Guide C-1
PPP Decoding Primer
Annotated traces
Identifier:
80 FD
Description:
Compression Control Protocol (CCP)
Following are the packet formats:
Packet Format ID Description
01
02
03
04
05
06
07
08
09
0A
0B
Configure Request
Configure Acknowledgment
Configure Non-Acknowledgment
Configure Reject
Terminate Request
Terminate Acknowledgment
Code Reject
Protocol Reject
Echo Request
Echo Reply
Discard Request
Note:
If a packet received from the wan fails the Cyclic Redundancy Check (CRC) the display is similar to the following, where
RBAD
denotes Received BAD:
RBAD-27:: 8712 octets @ 26CFE8
[0000]: fe dd dd dd dd dd dd dd dd dd dd dd dd dd dd dd
[0010]: dd dd dd dd dd dd dd dd dd dd dd dd dd dd dd dd
[0020]: dd dd dd dd dd dd dd dd dd dd dd dd dd dd dd dd
[0030]: dd dd dd dd dd dd dd dd dd dd dd dd dd dd dd dd
Annotated traces
Use the following traces as guides to help you decode other traces.
LCP Configure Request - MP+, MRU of 1524, MRRU of 1524 and End Point Discriminator using the device’s MAC address:
XMIT-3:: 29 octets @ 2C2E94
[0000]: ff 03 c0 21 01 01 00 19 00 04 00 00 01 04 05 f4
[0010]: 11 04 05 f4 13 09 03 00 c0 7b 4c e0 4c
This is a second LCP Configure Request from the same device. Everything in the packet is identical to the previous packet, except the ID number has incremented from 01 to 02:
XMIT-3:: 29 octets @ 2C2E94
[0000]: ff 03 c0 21 01 02 00 19 00 04 00 00 01 04 05 f4
[0010]: 11 04 05 f4 13 09 03 00 c0 7b 4c e0 4c
C-2 APX 8000/MAX TNT/DSLTNT Administration Guide
PPP Decoding Primer
Annotated traces
LCP Configure Request - CHAP authentication, Magic number
RECV-3:: 19 octets @ 2BEB8C
[0000]: ff 03 c0 21 01 60 00 0f 03 05 c2 23 05 05 06 4e
[0010]: 36 c9 05
LCP Configure Acknowledgment - This device will authenticate using CHAP. The Magic number is also acknowledged:
XMIT-3:: 19 octets @ 2C2E94
[0000]: ff 03 c0 21 02 60 00 0f 03 05 c2 23 05 05 06 4e
[0010]: 36 c9 05
LCP Configure Reject - MP+, MRU of 1524, MRRU of 1524 and End Point Discriminator.
This rejection shows two things. It shows that the remote side does not support MP+ or MP, since MP+ and the MRRU were rejected. This will have to be a PPP connection. Also, since the MRU of 1524 was rejected, the default of 1500 is assumed. There needs to be an MRU, so a rejection of a given value only means to use the default value.
At this point, this device will need to retransmit another LCP Configure Request, removing all the rejected options.
RECV-3:: 29 octets @ 2BF1A4
[0000]: ff 03 c0 21 04 02 00 19 00 04 00 00 01 04 05 f4
[0010]: 11 04 05 f4 13 09 03 00 c0 7b 4c e0 4c
LCP Configure Request - Note all values that were previously rejected are no longer in the packet:
XMIT-3:: 8 octets @ 2C2E94
[0000]: ff 03 c0 21 01 04 00 04
LCP Configure Acknowledgment -
RECV-3:: 8 octets @ 2BF7BC
[0000]: ff 03 c0 21 02 04 00 04
At this point, since both sides have transmitted LCP Configure Acknowledgments, LCP is up and the negotiation moves to the authentication phase.
This device receives a CHAP challenge from the remote end:
RECV-3:: 21 octets @ 2BFDD4
[0000]: ff 03 c2 23 01 01 00 11 04 4e 36 c9 5e 63 6c 63
[0010]: 72 34 30 30 30
This device transmits its encrypted user name and password:
XMIT-3:: 36 octets @ 2C2E94
[0000]: ff 03 c2 23 02 01 00 20 10 49 b8 e8 54 76 3c 4a
[0010]: 6f 30 16 4e c0 6b 38 ed b9 4c 26 48 5f 53 65 61
[0020]: 74 74 6c 65
The remote device sends a CHAP Acknowledgment:
RECV-3:: 8 octets @ 2C03EC
[0000]: ff 03 c2 23 03 01 00 04
APX 8000/MAX TNT/DSLTNT Administration Guide C-3
PPP Decoding Primer
Annotated traces
At this point, the negotiation moves from authentication to negotiation of Network Control
Protocols (NCPs). The TAOS unit supports Bridging Control Protocol (BCP), IPCP, IPXCP and ATCP.
IPCP Configure Request - Van Jacobsen Header Compression, IP address of 1.1.1.1
RECV-3:: 20 octets @ 2C0A04
[0000]: ff 03 80 21 01 e3 00 10 02 06 00 2d 0f 00 03 06
[0010]: 01 01 01 01
BCP Configure Request -
RECV-3:: 8 octets @ 2C101C
[0000]: ff 03 80 31 01 55 00 04
IPCP Configure Request - IP address of 2.2.2.2
XMIT-3:: 14 octets @ 2C2E94
[0000]: ff 03 80 21 01 01 00 0a 03 06 02 02 02 02
IPCP Configure Reject - Van Jacobsen Header Compression. The remote device should send another IPCP Configure Request and remove the request to do VJ Header Compression:
XMIT-3:: 14 octets @ 2C2E94
[0000]: ff 03 80 21 04 e3 00 0a 02 06 00 2d 0f 00
BCP - Protocol Reject. This local device is not configured to support bridging.
XMIT-3:: 8 octets @ 2C2E94
[0000]: ff 03 80 31 08 55 00 04
IPCP Configure Acknowledgment
RECV-3:: 14 octets @ 2C1634
[0000]: ff 03 80 21 02 01 00 0a 03 06 01 01 01 01
IPCP Configure Request - Note VJ Header Compression is not requested this time.
RECV-3:: 14 octets @ 2C1C4C
[0000]: ff 03 80 21 01 e4 00 0a 03 06 02 02 02 02
IPCP Configure Acknowledgment
XMIT-3:: 14 octets @ 2C2E94
[0000]: ff 03 80 21 02 e4 00 0a 03 06 01 01 01 01
At this point, a PPP connection has been successfully negotiated. The caller was successfully authenticated by means of CHAP and IPCP was the only successfully configured NCP. IPX,
Appletalk and bridging will not be supported during this session.
Below are two packets used in determining link quality:
LCP Echo request packet
RECV-3:: 16 octets @ 2BEB8C
[0000]: ff 03 c0 21 09 01 00 0c 4e 36 c9 05 00 00 00 00
LCP Echo Response
XMIT-3:: 16 octets @ 2C2E94
[0000]: ff 03 c0 21 0a 01 00 0c 00 00 00 00 00 00 00 00
C-4 APX 8000/MAX TNT/DSLTNT Administration Guide
PPP Decoding Primer
Example of MP+ call negotiation
Example of MP+ call negotiation
LCP Configuration Request - MP+, MRU of 1524, MRRU of 1524, End Point Discriminator using the device’s MAC address:
XMIT-31:: 29 octets @ D803C
[0000]: ff 03 c0 21 01 01 00 19 00 04 00 00 01 04 05 f4
[0010]: 11 04 05 f4 13 09 03 00 c0 7b 5c d3 71
LCP Configure Request - MP+, MRU of 1524, PAP authentication is required. MRRU of
1524, End Point Discriminator using the device’s MAC address:
RECV-31:: 33 octets @ D4FBC
[0000]: ff 03 c0 21 01 01 00 1d 00 04 00 00 01 04 05 f4
[0010]: 03 04 c0 23 11 04 05 f4 13 09 03 00 c0 7b 53 f0
[0020]: 7a
LCP Configuration Acknowledgment -
RECV-31:: 29 octets @ D55CC
[0000]: ff 03 c0 21 02 01 00 19 00 04 00 00 01 04 05 f4
[0010]: 11 04 05 f4 13 09 03 00 c0 7b 5c d3 71
LCP Configuration Acknowledgment -
XMIT-31:: 33 octets @ D803C
[0000]: ff 03 c0 21 02 01 00 1d 00 04 00 00 01 04 05 f4
[0010]: 03 04 c0 23 11 04 05 f4 13 09 03 00 c0 7b 53 f0
[0020]: 7a
At this point, LCP is up. Next is the authentication phase. The local device agreed to authenticate using PAP, so it should transmit its user name and password. Note that it is not encrypted, and user name and password can be decoded very easily:
PAP Authentication Request - User name is shown in hexadecimal and must be converted to ascii. User name is 0x6a 0x73 0x6d 0x69 0x74 0x68 (jsmith) and password is 0x72 0x65 0x64
(red):
XMIT-31:: 20 octets @ D803C
[0000]: ff 03 c0 23 01 01 00 10 06 6a 73 6d 69 74 68 03 72
[0010]: 65 64
PAP Authentication Acknowledgment -
RECV-31:: 9 octets @ D5BDC
[0000]: ff 03 c0 23 02 01 00 05 00
Authentication is successful. Final negotiation determines protocols to be supported over the link.
Note:
MP+ was negotiated, and both devices begin sending MP+ packets from here. The data portion of the packet is identical to PPP, but there is an 8-byte MP+ header instead of the
2-byte PPP header:
In the following packet,
00 3d is the designation for a Multilink packet. The next byte designates whether this packet is fragmented. The next three bytes are the sequence number.
You’ll see them increment by one for each packet sent or received.
APX 8000/MAX TNT/DSLTNT Administration Guide C-5
PPP Decoding Primer
Example of MP+ call negotiation
Next, the 80 31 01 designates this as a BCP Configure Request:
RECV-31:: 20 octets @ D61EC
[0000]: ff 03 00 3d c0 00 00 00 80 31 01 01 00 0a 03 03
[0010]: 01 07 03 00
BCP Configure Request:
XMIT-31:: 20 octets @ D803C
[0000]: ff 03 00 3d c0 00 00 00 80 31 01 01 00 0a 03 03
[0010]: 01 07 03 00
BCP Configure Acknowledgment:
XMIT-31:: 20 octets @ D864C
[0000]: ff 03 00 3d c0 00 00 01 80 31 02 01 00 0a 03 03
[0010]: 01 07 03 00
BCP Configure Acknowledgment:
RECV-31:: 20 octets @ D67FC
[0000]: ff 03 00 3d c0 00 00 01 80 31 02 01 00 0a 03 03
[0010]: 01 07 03 00
BCP is up and the session begins sending bridged traffic. No routed protocols were negotiated.
The following packets are sent as part of the MP+ protocol. They are sent at one-second intervals. These packets are used by each unit to validate the existence of the link. It gives the devices a secure way to determine whether the link is still up, even if there is no data traffic passing between the devices.
RECV-31:: 8 octets @ D5BDC
[0000]: ff 03 00 3d c0 00 00 05
XMIT-31:: 8 octets @ D803C
[0000]: ff 03 00 3d c0 00 00 04
RECV-31:: 8 octets @ D61EC
[0000]: ff 03 00 3d c0 00 00 06
XMIT-31:: 8 octets @ D803C
[0000]: ff 03 00 3d c0 00 00 05
C-6 APX 8000/MAX TNT/DSLTNT Administration Guide
PPP Decoding Primer
Example of MP+ call negotiation
The following RFCs provide more detail about the subjects listed in their titles:
RFC1552
RFC1638
RFC1661
RFC1934
RFC1962
RFC1974
RFC1989
RFC1990
RFC1994
Identifier Title
RFC1378
PPP AppleTalk Control Protocol (ATCP)
PPP Internetwork Packet Exchange Control Protocol (IPXCP)
PPP Bridging Control Protocol (BCP)
Point-to-Point Protocol (PPP)
Multilink Protocol Plus (MP+)
PPP Compression Control Protocol (CCP)
PPP Stac LZS Compression Protocol
PPP Link Quality Monitoring
PPP Multilink Protocol (MP)
PPP Challenge Handshake Authentication Protocol
APX 8000/MAX TNT/DSLTNT Administration Guide C-7
Index
A
accounting displaying messages
displaying state of RADIUS session
session statistics
address pools, displaying information about
Addrpool command, using
adjacencies, displaying OSPF
Admin User profile default password for
logging in with
privileges with
Admin, logging in as
administrative profiles how created
Admin-State profiles, how created
Admin-State-Perm-If profile described
using
Admin-State-Phys-If profile described
using
Advanced Agent MIB, TAOS unit support
alarms, displaying T3
Answer Profile MIB, TAOS unit support for
areas, displaying OSPF
ARP adding a table entry
cache described
clearing the ARP table
deleting a table entry
inverse for Frame Relay
viewing the ARP table
ARPtable command, using
AS advertisements displaying external
displaying internal
AS border routers, information about
Ascend MIB advancedAgent group
atmpGroup
callStatusGroup
APX 8000/MAX TNT/DSLTNT Administration Guide configuration group
console group
described
doGroup
eventGroup
firewallGroup
flashGroup
hostStatus group
hostTypes group
lanModemgroup
lanTypes group
mCastGroup
mibanswerProfile
mibframeRelayProfile
mibinternetProfile
mibuds3NetworkProfile
miscGroup
multiShelf group
powerSupply group
products group
radiusGroup
sessionStatusGroup
slots group
systemStatusGroup
wanDialoutPkt group
Ascendump described
example of enabling
in local mode
obtaining
preliminary steps for
remote mode
specifying host installed on
AT command strings, modifying
ATM diagnostics with Framer command
displaying call blocks
displaying lines
looping back lines
status of lines
ATM, looping back
ATMDumpCall command, using
ATMP using ATMPdebug command
using DTunnel command to get information about
,
ATMP MIB, APX 8000 support
Index-1
Index
B
ATMPdebug command, using
Auth command logging in using
using
AuthenDebug command, using
authentication
Auth command
debugging
displaying LCP messages
logging in as different user
session statistics
SNMP
,
User profiles
using RADservdump to verify setup
B
backing up, APX 8000 configuration
Backoff Q full message, explained
Base profile described
information stored across resets
BrouterDebug command, using
BrouterLoad command, using
C
call blocks, ATM, displaying
Call MIB, APX 8000 support
calls dialout timer
displaying state of
end of call information reported by Syslog
example of incoming modem
example of MPP negotiation
forwarding info to Syslog when terminates
information about incoming call routing
channels bringing modem up or down
checking status of T1
displaying status of
overall state of
quiescing a channel
removing from service
CIDR displaying messages about
CLID, information in Syslog
clients, displaying IGMP
clock source
Index-2 preferred
viewing
viewing for slot card
clocking viewing source
viewing source for slot card
Code permission level, explained
Code-level command, permissions needed to use
commands
Addrpool
ARPtable
ATMDumpCall
ATMPdebug
AuthenDebug
BrouterDebug
BrouterLoad
Ctdebug
Cubit
Debug overview
Device
DS3ATMlines
DS3Link
DTunnel
E1-Stats
Ether-Display
Ether-Stats
FE-Loop
Finger
for status window
Framer
,
FRDLstate
FRdump
FRinARP
FRLinkState
FRLMI
FRMgrDump
FRPriorityErrors
FRScert
FRstate
GRE
If-Admin
IFMgr
IGMP
IProute
IPXRIPdebug
Lanval
LifDebug
Line
list of debug
MdbStr
,
MDialout
MDialSess
Modem
ModemD1Stats, ModemD2Stats, ModemD3Stats
,
ModemDrvDump
APX 8000/MAX TNT/DSLTNT Administration Guide
ModemDrvState
MPCMtoggle
MPentry
MPPCM
MPtoggle
MSstat
NetIF
Netstat
NSlookup
OAMLoop
Open
Open on slave shelf
OSPF
overview of
overview of shelf controller
PBecho
permission levels
permissions described
Ping
,
Pool
,
PortInfo
PPPdump
PPPFSM
PPPinfo
PPPstate
PRIdisplay
Quiesce
RADacct
RADif
RADservdump
RADsessdump
RADstats
Reset
Revision
Rlogin
RoutMgr
SAR
Show
,
Show Netware Networks
Show Netware Servers
Slot
SNTP
StackLimit
T1Channels
T1-Stats
TDM
,
TDMtst
Telnet
TelnetDebug
TNTMP
TraceRoute
TSshow
TunnelDebug
TunnelSlot
UDS3Dump
UDS3Lines
Update
APX 8000/MAX TNT/DSLTNT Administration Guide
Index
C
Userstat
using combinations of debug
WANdisplay
WANdsess
WanEventsStats
WANopening
WANtoggle
configuration backing up profiles
clearing
displaying system options
Log profile
refreshing from RADIUS
removing slot card
restoring
restoring from a local file
restoring from a network
saving to a local file
saving to a network host
scripts, using
SNMP profile
SNMP traps
User profile
via SNMP
Connection profile
Frame Relay Direct
Connection status
connections displaying information about MP
displaying information about MP and MPP
displaying information about MPP
displaying information about MPP and MP
displaying information about setup
information about
terminating user
console, fatal crash information on
core dump disabling
enabling
enabling on MAX TNT
examples of
in multishelf system
initiating immediate
MAX TNT in local mode
naming conventions for files
overview of
preliminary steps for
pulling from TNT
remote mode
specifying server
trigger events
troubleshooting
UDP port numbers for
Coredump command, described
core-dump server, restrictions on
Index-3
Index
D
Ctdebug command, using
Cubit command, using
D
D channel, displaying signaling
D4 framing, cannot be used with FDL
data link, information for Frame Relay
date, setting system
debug commands getting online help for
list of
overview of
using combinations of
debug levels, described
debug output, enabling
debug permissions enabling
levels explained
debug profiles, deleting
Debug-level commands
TNTMP
default administrative password
Default User profile, privileges with
defaults, restoring system to
Device command, using
devices changing state of
changing state of with Admin-State-Perm-If profile
,
changing state of with Admin-State-Phys-If profile
,
managing
quiescing
Device-State profile, using
Device-Summary profile, using
Diagnostic permission level, explained
Diagnostic-level commands, permission needed to use
,
diagnostics
ATM with Framer command
getting DS1
getting T3
dialout
MDialout command
timer for
Dircode command, using
directed broadcasts, setting displayed in IFmgr command output
disabling modem, explained
DLCI
displaying which applied to Frame Relay link
displaying with the FRMgrDump command
DNIS, information in Syslog
DNS, performing a DNS lookup
DS1 MIB, described
DS1s getting diagnostics for
status codes
DS2 lines displaying state of
status codes
DS3 ATM card administering
using the ATMDumpCall command
using the Framer command
DS3 lines checking status of unchannelized
DS3 MIB, described
DS3 Profile MIB, APX 8000 support
DS3-ATM profile, using
DS3ATMlines command, using
DS3Link command, using
DTPT, cannot terminate sessions with Userstat
DTunnel command, using
E
E1 lines displaying clock source information
getting diagnostics for
monitoring
E1-Stats command, using
error information
error messages
did not negotiate MPP
cannot establish connection for
cannot find profile for
far end does not support remote management
far end rejected session
management session failed
not authorized
profile for does not specify MPP
errors definition of fatal
logged by Syslog
on T1 channels
status window, displayed
Ether-Display command, using
Ethernet
APX 8000 monitors interface state
Index-4 APX 8000/MAX TNT/DSLTNT Administration Guide
Index
F
displaying information about a particular interface
,
displaying interfaces
displaying statistics about
enabling or disabling interfaces
how link state affects routing table
multiple IP interfaces on port
viewing link state
viewing packet contents
Ethernet card, administering
Ethernet interface marking as up or down
specifying management only
Ether-Stats command, using
Event MIB, APX 8000 support
events types of
WAN
External-Auth profile, verifying configuration in
Flash MIB, APX 8000 support
Format command, using to format flash cards
Frame Relay data link information on
FRDLstate command
FRdump command
FRinARP command
FRLinkState command
FRLMI command
FRMgrDump command
FRPriorityErrors command
FRScert command
FRstate command
state changes
Userstat command and
Frame Relay MIB, described
Frame Relay Profile MIB, APX 8000 support
Framer command, using
FRDLstate command, using
FRdump command, using
FRinARP command, using
FRLinkState command, using
FRLMI command, using
FRMgrDump command, using
FRPriorityErrors command, using
FRScert command, using
FRstate command, using
Fsck command, using to check flash card format
F
factory configuration, displaying
fatal error log core dumps and
described
logging message to when stack reaches limit
reading
fatal error messages described
format of
fatal errors crash information on console
definition of
description of
FDL
D4 framed lines and
specifying
features, displaying enabled
FE-Loop command, using
Finger forwarding service not supported
using command
Firewall MIB, APX 8000 support
flash card described
displaying contents of
displaying directory information
file-system checking a card
formatting
overflow from loading unknown cards
performing a file system check
flash card slots, on APX 8000 shelf controller
G
GRE command, using
groups displaying IGMP
finding channels associated with nailed
H
hash codes, using Update commands with
HDLC card testing communication between
help, getting for debug commands
hidden routes, IPX
host card, displaying WAN events for
hosts
DNS lookups
logging into network
APX 8000/MAX TNT/DSLTNT Administration Guide Index-5
I
Index
I
Idle logout
Idle parameter
If-Admin command administering SNMP interfaces with
examples
IFMgr command using
viewing multiple IP interfaces on Ethernet port with
,
IGMP client information
diagnostic tools for
group information
IGMP command displaying client information
using
inband signaling
installation, recovering from failed slot card
interfaces active IGMP
description of table
diagnostic tools for IGMP multicast
displaying network mappings
displaying with Netstat command
enabling and disabling Ethernet
enabling or disabling Ethernet
Frame Relay
how IP interfaces are created
information about a particular Ethernet
initiating changes in SNMP
managing SNMP
multicast forwarding
multiple IP on Ethernet port
OSPF
OSPF, displaying
permanent defined
resetting SNMP table
SNMP
,
SNMP described
specifying management only
table of Ethernet
the IP interface table
transient defined
viewing Ethernet link state
Internet Profile MIB, APX 8000 support
IP displaying and modifying routes
interfaces displayed with Netstat command
multiple interfaces on Ethernet port
system administration for
IP addresses, displaying
IP routing table, displaying
IProute command described
using to temporarily modify routing table
IP-Route profile, routes restored after reset
IPX diagnostic tools for
IPXRIPdebug command
IPXRIPdebug command, using
ISDN
LifDebug command
PRIdisplay command
quiescing PRI line
L
Lan Modem MIB, APX 8000 support
LAN-Modem profile
Lanval command, using
LCP authentication, displaying messages related to
LifDebug command, using
Line command, using
Line status window channel status codes in
link status codes in
lines
displaying DS2 state
displaying T3 statistics
DS1 status
DS2 status
overall state of
removing PRI from service
status of
link state
Frame Relay
OSPF advertisements
OSPF database
viewing link state
link-state database, displaying
LMI displaying information about
displaying Sprint or Frame Relay forum checks
Load command, loading code for specific card
Load-Select profile, how to use
log messages in status window
level displayed on a per-user basis
status window, displayed
Log profile displaying contents
example configuration
how many messages to save
message level
Index-6 APX 8000/MAX TNT/DSLTNT Administration Guide
number of messages
syslog daemon
logging as different user
configuring Syslog
levels for User profiles
setting up Syslog
specifying remote port for Syslog
specifying session ID base
logging in as a different user
described
login and User profiles
determining current user profile
displaying status windows
to network host using Rlogin
to network host using Telnet
to network hosts from APX 8000
logout, for idle sessions
loopback enabling external for T3
enabling for T1 interface
enabling for T3
enabling internal for T3
M
Maintenance-State command. using
management, specifying Ethernet interface for
MdbStr command, using
MDialout command, using
MDialSess command, using
memory displaying NVRAM used
displaying pools
NVRAM
messages
Backoff Q full
definition of warning
fatal and warning error described
fatal error definitions
format of fatal and warning
log for User profiles
log messages in status window
specifying levels of debug
Syslog
MIBs
Ascend
Ascend enterprise
Ascend MIB hierarchy
Frame Relay
Modem
APX 8000/MAX TNT/DSLTNT Administration Guide
Index
M
support on APX 8000
Modem card, administering
Modem command, using
modem dialout, active sessions
Modem MIB, described
modem strings, revert to default values after reset
ModemD1Stats, command, using
ModemD2Stats command, using
ModemD3Stats command, using
ModemDrvDump command, using
ModemDrvState command, using
modems bringing channel up or down
disabling
displaying status
MdbStr command
MDialSess command
ModemD1Stats, ModemD2Stats, ModemD3Stats commands
ModemDrvDump
ModemDrvState command
monitoring
quiescing
monitoring
E1 lines
UDS3 card
MP displaying information about
ID number
MPCMtoggle command, using
MPentry command, using
MPP displaying information about
displaying information about connections
example of call negotiation
MPPCM command, using
MPtoggle command, using
MSstat command, using
multicast diagnostic tools for interfaces
IGMP client information
IGMP group information
multicast forwarding, administration
Multicast MIB, APX 8000 support
multichannel connections, debugging
multishelf
PBecho command
SAR command
statistics about
TDM command
using Cubit command to monitor
multishelf bus, displaying communications over
Index-7
Index
N
Multishelf MIB, APX 8000 support
N
nailed connections, refreshing from RADIUS
nailed group finding channel associated with
name, specifying for APX 8000
negotiation modifying modem
user session messages
neighbors, displaying OSPF
NetIF command, using
Netstat command displaying the interface table
using
using to display routing table
network administration
IPX
logging into network hosts
multicast interfaces
OSPF tools for
performing a DNS lookup
pinging hosts
Rlogin sessions
TCP/IP networks
Telnet sessions
tracing routes
viewing the ARP table
network connectivity, testing with Ping
NFAS signaling
Nslookup command, using
NVRAM displaying amount used
managing
not cleared when you remove slot card
using to recover from slot card upgrade
O
OAMLoop command, using
Open command cannot use on slave shelf
using
OSPF diagnostic tools for
displaying the routing table
external AS advertisements, displaying
general information about
information about areas
information about AS border routers
information about link-state database
Index-8 interfaces
interfaces, displaying information about
internal AS advertisements, displaying
link-state advertisements
link-state database
neighbors
routing table
OSPF command, using
outbound modem calls displaying information about
P
packet bus traffic on
packets displaying for particular user
displaying packets received from or sent to WAN
,
formats in PPP sessions
viewing Ethernet
parameters
Idle
passwords assigning to Admin login
default Admin
permissions needed to view
required for logging into system
requiring for serial port
PBecho command using
PCMCIA flash cards
permanent interface, defined
permission levels
Code explained
Debug explained
Diagnostic explained
System explained
Term-Serv explained
Update explained
User explained
permissions
Allow-Code
Allow-Diagnostic
Allow-Password
Allow-System
Allow-Termserv
Allow-Update
described
enabling debug
levels
logging in as Admin
Ping command, using
APX 8000/MAX TNT/DSLTNT Administration Guide
Pools command, using
PortInfo command, using
ports displaying port info
information about TCP and UDP
specifying remote for Syslog
UDP for core dump
Port-State events, not supported on APX 8000
Power command, using
power supplies, checking status of
Power Supply MIB, APX 8000 support
PPP annotated traces in sessions
APX 8000 name used for session
displaying session info
frame formats in negotiation
most common protocols in negotiations
packet formats in sessions
state information
using WANdisplay to resolve PPP negotiation problems
PPPdump commands, using
PPPFSM command, using
PPPinfo commands, using
PPPstate command, using
PRI displaying D-channel signaling
quiescing
PRIdisplay command, using
profiles administrative
administrative, how created
Admin-State-Perm-If
Admin-State-Phys-If
Base information stored across resets
Connection
Frame Relay Direct
Device-State
Device-Summary
DS3-ATM
,
refreshing nailed
sample SNMP
sample User
Slot-Info
Slot-State
SNMP overview
T1-Stat
UDS3-Stat
User pre-defined
prompts, specifying for User profile
protocols
ARP
IGMP
most common
Index
Q
OSPF
SNTP
statistics
Telnet
UDP, probe
Q
queue depth, displaying
Quiesce command and switch types
example use
quiescing T1 lines (in T3 card) or channels
quiescing T1 lines or channels
R
RADacct command, using
RADif command, using
RADIUS
RADacct command
RADif command
RADservdump command
RADsessdump
RADstats command
refreshing configuration
refreshing nailed profiles from
running in debug mode
RADIUS MIB, APX 8000 support
RADservdump command, using
RADsessdump command, using
RADstats commands, using
remote management session, timing out
Reset command, using
resetting single shelf system
restoring saved configurations
Revision command, using
revision, displaying system
RFC 1213, APX 8000 support
RFC 1253, APX 8000 support
RFC 1315,APX 8000 support
RFC 1317, APX 8000 support
RFC 1398, APX 8000 support
RFC 1406, APX 8000 support
RFC 1695, APX 8000 support
RFC 1695, described
RFC 1696, APX 8000 support
APX 8000/MAX TNT/DSLTNT Administration Guide Index-9
Index
S
RIP, displaying IPX RIP traffic
Rlogin command, using
routes adding static to routing table
changing
displaying and modifying IP
hidden and static IPX
routing displaying router backlog time
IPX diagnostic tools
IPX RIP traffic
OSPF areas
OSPF AS border routers
OSPF external AS advertisements
OSPF information
OSPF internal AS advertisements
OSPF link-state advertisements
OSPF link-state database
OSPF neighbors
OSPF routing table
tracing routes
using BrouterDebug command to get information about
routing table adding static route to
displaying and modifying
displaying with Netstat command
fields explained
how affected by link state
modifying temporarily
RoutMgr command, using
S
SAR command, using
SAR, statistics for
Screen command, status window length and
scripts, configuring APX 8000 with
Secure Access Firewall, Syslog messages initiated by
,
security changing Admin password
overview of SNMP
securing the serial port
serial number, viewing
serial port, securing
serial WAN card displaying information
Service Management MIB, APX 8000 support
session IDs, specifying base for
Session MIB, APX 8000 support
sessions annotated PPP traces
debugging Telnet
displaying information about using Finger
displaying packets for particular session
displaying setup messages
displaying user information
example of MPP negotiation
logging out idle
opening with slot card
PPP info
PPP state information
Syslog information about
terminating
shelf controller, commands available on
Show command types of slot cards reported
viewing slot cards with
Show Netware Networks command
Show Netware Servers command
slave shelf, cannot use Open command
slot cards administering UDS3
changing state of
changing state of in Slot-State profile
commands on
displaying uptime for
DS3 ATM, administering
Ethernet, administering
getting core dump from
installed reported by Slot-Info profile
loading software for
loading software for new cards
loading software for specific cards
managing
modem, administering
opening session with
recovering from failed installation
removing card and configuration
removing from system
Slot command to temporarily down
software images stored on flash card
T1, T3 administering
type reported by Show command
viewing clock source for
viewing information about particular card
viewing installed
viewing status of
Slot command on slave shelf
to temporarily down a slot card
using
Slot-Info profile, using
Slot-State profile, using
SNMP
Index-10 APX 8000/MAX TNT/DSLTNT Administration Guide
access and security overview
address security
Ascend enterprise MIB
Ascend MIB
Ascend MIB hierarchy
Ascend MIB support
classes of traps generated
community string for SNMP PDU
community strings
DS1 MIB
DS3 MIB
enabling access to the unit
Frame Relay MIB
host to receive traps
If-Admin command
individual trap support on APX 8000
initiating interface changes
interacting with manager utilities
interface numbers
interfaces allocated at startup
managing interfaces
managing SNMP interfaces
Modem MIB
resetting interface table
sample profile
setting up traps
TAOS unit support
trap configuration overview
trap example
trap support on APX 8000
traps, defined
SNMP interface table, how built
SNMP profile configuration overview
displaying contents
example configuration
SNTP command, using
software loading for new cards
loading for specific card
slot card stored on flash card
upgrading system
StackLimit command, using
state changing device
changing slot card
static routes adding to routing table
IPX
statistics getting DS1
status
channel status codes
checking T1
checking T1 channels
APX 8000/MAX TNT/DSLTNT Administration Guide
Index
S
checking UDS3
connections
displaying modem
displaying serial WAN
displaying T3
displaying UDS3
displaying WAN
general information
line status
log messages
T1 card
T3 card
User profiles, and
WAN lines
status window commands for
connection information
connections
default contents of
default size
defining contents
described
displaying
displaying upon login
general
information displayed in for User profile
length
line status
log
navigating
opening and closing
vt100 requirement
WAN line information in
Syslog configuring
configuring APX 8000 to interact with
configuring daemon
DNIS and CLID information in
end of call information for
forwarding call info to when call terminates
messages
messages initiated by Secure Access Firewall
specifying remote port
system checking power supplies
configuration stored in NVRAM
configuring with a script
displaying revision
displaying uptime
removing slot card
removing slot card from
resetting
restoring configuration from a local file
restoring configuration from a network host
saving configuration to a local file
Index-11
Index
T
saving configuration to a network host
setting date and time
updating with hash codes
version
viewing installed slot card
system administration allowing remote management
core dumps
device state changes
devices, managing
displaying the contents of flash
displaying the system version
file system checking a flash card
log messages
logging in as Admin
logging in with Admin User profile
network overview
overview
quiescing modems
quiescing T1 lines (in T3 card) or channels
quiescing T1 lines or channels
session IDs
setting a system name
slot cards, managing
SNMP interfaces
system-level commands
TCP/IP
system options, displaying
System permission level, explained
System profile allowing remote management
setting a system name
setting session ID base
system software, after upgrade if slot card does not come up
system software, upgrading
system status
System-level commands described
permissions needed to use
T
T1 card opening session to
T1 channels checking status of
monitoring on T1 card
quiescing
T1 interface, enabling loopbacks
T1 lines checking status of
configuring via SNMP
displaying clock source information
Index-12 displaying status of on T3 card
getting diagnostics for
monitoring performance (FDL)
quiescing
quiescing and switch types
quiescing ISDN PRI
T1Channels command using
using on T3 card
T1-Stat profile
T3 card and,
using
T1-Stats command, using
T3 alarms, displaying
T3 card displaying status of T1 lines
displaying status of unchannelized lines
getting DS1 diagnostics for
opening session with
using the DS3Link command
using theT1Channels command
T3 lines
C-bit parity and
configuring via SNMP
displaying status of
enabling external loopback
enabling internal loopback
enabling loopback
getting diagnostics for
tables, routing and interface
TAOS unit displaying enabled features
logging in
resetting
serial number of
SNMP support
system administration overview
upgrading system software
TCP, displaying information about
TCP/IP, system administration for
TDM bus setting up and querying
test
testing
TDM command using
TDMtst command using
Telnet command, using
Telnet, debugging
TelnetDebug command, using
Terminal-Server, permissions needed to use
Term-Serv permission level, explained
APX 8000/MAX TNT/DSLTNT Administration Guide
time, setting system
timeouts, specifying idle
timer, for dialout calls
TNTMP command
TraceRoute command, using
traces, annotated
transient interface, defined
Trap profile displaying contents
example configuration
traps
Ascend enterprise
configuration overview
example of
setting up
support for individual on APX 8000
support on APX 8000
trigger events, for core dumps
TSshow command, using
TunnelDebug command, using
tunneling
ATMPdebug command
displaying setup messages
DTunnel command
TunnelDebug command
TunnelSlot command
TunnelSlot command, using
U
UDP ports for core dump
information about
UDS3 displaying status
lines, displaying
statistics, displaying
UDS3 card administering
monitoring
UDS3 lines, displaying status of on UDS3 card
UDS3 Profile MIB, APX 8000 support
UDS3Dump command, using
UDS3Lines command, using
UDS3-Stat profile, using
Update command, using
Update commands, permissions needed to use
Update permission level, explained
Update-level commands, Reset
upgrade, if slot card does not come up after
Index
U
uptime displaying
displaying system
User permission level, explained
User profiles customizing environment of
default password for Admin
determining current
example configuration
information displayed in status window for
log levels for
logging in as different user
logging in using
logging in using different
name and password
parameters described
permission levels
permission levels for
pre-defined
restoring default due to inactivity
samples
specifying system prompt for
status information settings
status window settings
status windows and log messages
user name as prompt
user session information, displaying
username and password, requiring for serial port
users displaying active
displaying information about using Finger
displaying packets for session
terminating sessions
Userstat command configuring format of output
using
using to display active users
V
validation
Lanval command
requests for
Version command, using
W
WAN displaying counters of events
displaying events for
displaying packets
displaying packets during connection setup
WANtoggle command
APX 8000/MAX TNT/DSLTNT Administration Guide Index-13
Index
W
WAN Dialout MIB, APX 8000 support
WAN lines displaying status of
information about
status codes
WAN MIB, APX 8000 support
WANdisplay command stopping output
using
WANdsess command, using
WanEventsStats command
WANopening command, using
WANtoggle command, using
warning messages definition of
format of
Write command, -f forces change
Index-14 APX 8000/MAX TNT/DSLTNT Administration Guide
Download
Advertisement
Key features
High-speed data connectivity
Support for various network protocols
Security features
Remote management capabilities
Slot card administration
TAOS system administration
Network administration
Debug commands
User profile creation
SNMP administration
Frequently asked questions
Use the 'show slot' command to view the installed slot cards.
Use the 'set clock' command to set the system time and date.
Use the 'ping' command to test the connectivity of a network host.
Use the 'debug' command to enable debug output.
Use the 'user' command to create a user profile.