HP 11i Version 1 -UX operating system Installation and Update Guide
PDF
문서
광고
광고
HP-UX 11i Version 1 Installation and Update Guide HP Servers and Workstations Manufacturing Part Number : 5991-0662 December 2004, Edition 13 Printed in the United States © Copyright 1983-2004 Hewlett-Packard Development Company, L.P. Legal Notices Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. HP-UX Release 10.20 and later and HP-UX Release 11.00 and later (in both 32- and 64-bit configurations) on all HP 9000 computers are Open Group UNIX 95 branded products. Intel and Itanium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Java is a US trademark of Sun Microsystems, Inc. UNIX is a registered trademark of The Open Group. Windows and Windows NT are U.S. registered trademarks of Microsoft Corporation. This product includes software developed by the Apache Software Foundation. This documentation is based on information from the Apache Software Foundation (http://www.apache.org). This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit (http://www.openssl.org). This product includes cryptographic software written by Eric Young ([email protected]). This product includes PHP, freely available from the PHP Group (http://www.php.net). This product includes software developed by the OpenLDAP Project (http://www.openldap.org). 2 Contents About This Document Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Publishing History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Document Organization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Typographical Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HP-UX Release Name and Release Identifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HP-UX 11i v1 Resources. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Third-Party Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Other HP Web Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HP Encourages Your Comments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 13 14 16 17 18 18 21 21 24 1. Welcome to HP-UX 11i Version 1 Media Kit Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 HP-UX 11i v1 Operating Environments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 The Next Step. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 2. System Requirements for Cold-Installing and Updating System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . How to Plan Your Disk Space Needs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Disk Space Allocation for File Partitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Disk Space Requirements for a Cold-Install . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Disk Space Requirements for an Update . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Supported Servers and Workstations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Unsupported Servers and Workstations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Supported Network Drivers, Mass Storage Drivers, and SCSI Devices . . . . . . . . . . . . Supported Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Identification of Model, OS/OE, and Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . The Next Step. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 33 33 34 35 36 42 43 44 45 47 3. Choosing an Installation Method Supported Cold-Install Paths to HP-UX 11i v1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Supported Update Paths to HP-UX 11i v1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Deciding Which Method to Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . When to Cold-Install. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 51 53 54 3 Contents When to Update . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Additional Cold-Install Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Additional Update Considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . If You Have an Existing HP-UX 11i v1 System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standard HP-UX Bundle Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Patch Management Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Online Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . The Next Step. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 56 57 58 59 59 60 61 4. Preparing to Install or Update to HP-UX 11i v1 Cold-Install Tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Task 1: Backing Up Your Configuration Files. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Task 2: Backing Up Your System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Task 3: Updating Your Ignite-UX Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Task 4: Locating Source Media and Codewords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Update Tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Task 1: Identifying Software Versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Task 2: Rebuilding the Kernel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Task 3: Renaming Your Log Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Task 4: Backing Up Your System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Task 5: Locating Source Media and Codewords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Backing Up Your System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Task 1: Backing Up Your Data Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Task 2: Creating an Operating System Recovery Archive . . . . . . . . . . . . . . . . . . . . . Locating Source Media and Codewords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . The Next Step. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 64 65 65 66 67 67 67 68 68 68 69 69 70 72 74 5. Cold-Installing HP-UX 11i v1 Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reviewing the Cold-Install Process. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cold-Installing HP-UX 11i v1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Task 1: Booting Your Machine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Task 2: Selecting Your Installation Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Task 3: Configuring Your Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Task 4: Deselecting OE Software Bundles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Task 5: Finishing Your Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 76 77 79 80 81 82 84 85 Contents Retrieving Information After Cold-Installing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 The Next Step. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 6. Updating to HP-UX 11i v1 Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 Updating Netscape Directory Server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 Reviewing the Update Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 Updating Tips. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 Updating to HP-UX 11i v1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 Task 1: Creating a Network Depot (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 Task 2: Installing the Latest Update-UX Bundle (Required). . . . . . . . . . . . . . . . . . 100 Task 3: Using update-ux (Required) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 Post-Update Task: Configuring OE Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 The Next Step. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 7. Installing HP Applications and Patches Installing HP-UX Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tips for Installing or Updating HP Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . Installing HP-UX Applications from the DVD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HP-UX Patching and Patch Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . The Next Step. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 114 115 117 118 8. Verifying System Install or Update Verifying the HP-UX Cold-Install or Update . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Task 1: Listing All Software Installed on Your System . . . . . . . . . . . . . . . . . . . . . . Task 2: Verifying Bundles Are Installed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Backing Up the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . The Next Step. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 120 121 122 123 A. Booting HP Servers and Workstations Halting the Autoboot Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Booting Workstations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Booting HP Servers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Booting V-Class Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Searching for Other Bootable Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 127 129 132 134 5 Contents B. Known Problems and Troubleshooting Known Problems Discovered in This Release. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Install Known Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Update Known Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Common Install and Update Error and Warning Messages . . . . . . . . . . . . . . . . . . . . Problems Reading HP-UX 11i v1 DVD Media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Problems Configuring HP-UX 11i v1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Kernel Build Warnings for krm Module During Cold-Install or Update. . . . . . . . . cdrecord Application Requires Patch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Enabling AutoFS on High Availability Servers Can Cause NFS Packages to Be Dropped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hardware Information Not Captured on Systems with Floppy Drive. . . . . . . . . . . Auto-Port Aggregation Will Not Work on rp7410 Systems . . . . . . . . . . . . . . . . . . . EISA Cards Not Supported on 64-bit OS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100BT HSC-FX Cards Do Not Work on HP-UX 11i v1. . . . . . . . . . . . . . . . . . . . . . . SCSI PCI Restrictions for OLA/R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SCSI PCI HBA Documentation Correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HP-UX Apache-based Web Server Requires LD Patch to Start and Stop . . . . . . . . Problems with Large Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Un-installing HP-UX 11i v1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Re-installing SD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Recovering a Corrupt System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Patch Required for fbackup (1M) and frecover (1M) on SDLT320, SDLT220, and DLTvs80 Tape Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Verifying and Adding Diagnostic Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Problems Affecting Non-C Locales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Difference Between English and Japanese HP-UX STK . . . . . . . . . . . . . . . . . . . . . Warning When Updating to Non-C locales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 137 142 153 160 163 163 163 164 165 165 166 166 166 167 169 170 171 172 173 173 174 175 175 175 C. HP-UX 11i v1 Software Bundles Core Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Always Installed Software (Stand-Alone) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Always-Installed Software (OE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Always-Installed Network and Mass Storage Drivers. . . . . . . . . . . . . . . . . . . . . . . . . Default-Installed Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Selectable Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 178 179 180 183 184 186 Contents Selectable Network Drivers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187 D. Configuring Built-In PCI Networking 1000Base-T (Gigabit Ethernet) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Optional Step: Configure Jumbo Frame Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Optional: Troubleshooting a Fast Ethernet Migration to HP-UX 11i . . . . . . . . . . . . How the Automatic Merge Works Using the BTLAN.100 Script . . . . . . . . . . . . . . . Optional: Manual Merging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Manual Merging Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 190 192 192 193 193 E. Controlling Memory Utilization of VxFS 3.5 on HP-UX 11i v1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Controlling the inode Cache . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Controlling the Buffer Cache. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Conclusion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198 199 200 201 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203 7 Contents 8 Tables Table 1. Publishing History Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Table 2. HP-UX 11i Releases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Table 1-1. Supported Operating Environments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 Table 2-1. File Partition Disk Space Allocation by Operating Environment . . . . . . .34 Table 2-2. Supported Servers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 Table 2-3. Supported Workstations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41 Table 3-1. Updating from Previous HP-UX Releases . . . . . . . . . . . . . . . . . . . . . . . . . .51 Table 3-2. December 2004 Patch Bundles (by Media Location). . . . . . . . . . . . . . . . . .58 Table 4-1. HP Licensing Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73 Table 6-1. Updating Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96 Table B-1. Known Install and Update Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . .136 Table B-2. Known Install Problems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .137 Table B-3. Known Update Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .142 Table B-4. Common Install and Update Error and Warning Messages . . . . . . . . . .153 Table C-1. Core Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .178 Table C-2. Always Installed Software (Stand-Alone) . . . . . . . . . . . . . . . . . . . . . . . . .179 Table C-3. Always-Installed Software by Operating Environment . . . . . . . . . . . . . .180 Table C-4. Default-Installed Software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184 Table C-5. Selectable Software (All OEs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186 9 Tables 10 Figures Figure 5-1. Cold-Installing HP-UX 11i v1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78 Figure 6-1. Updating to HP-UX 11i v1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95 11 Figures 12 About This Document This guide describes installing (called cold-installing) and updating your HP 9000 system to the latest release of HP-UX 11i v1. The document printing date and part number indicate the document’s current edition. The printing date will change when a new edition is printed. Minor changes may be made at reprint without changing the printing date. The document part number will change when extensive changes are made. Document updates may be issued between editions to correct errors or document product changes. The latest version of this document can be found online at the HP Technical Documentation Web site: http://docs.hp.com/ Intended Audience This document is intended for system administrators responsible for installing, configuring, and managing HP-UX 11i v1 on HP 9000 systems. Administrators are expected to have knowledge of operating system concepts, commands, and configuration. This document is not a tutorial. Publishing History To ensure that you receive the latest edition, you should subscribe to the appropriate product support service. Contact your HP sales representative for details. Table 1 Document Manufacturing Part Number Publishing History Details Operating Systems Supported Supported Product Versions Publication Date 5991-0662 HP-UX 11i v1 B.11.11 December 2004 5990-7279 HP-UX 11i v1 B.11.11 June 2004 5187-4496 HP-UX 11i v1 B.11.11 December 2003 13 Document Organization The HP-UX 11i Version 1 Installation and Update Guide is divided into many chapters and appendixes, which contain information about installing and updating HP-UX 11i v1. IMPORTANT The Read Before Installing or Updating to HP-UX 11i Version 1 DVD booklet that comes with the HP-UX 11i v1 media contains last-minute cold-install and update information that was not available when this guide was published. Make sure to review the booklet before continuing. • Chapter 1, “Welcome to HP-UX 11i Version 1,” on page 25 Use this chapter to learn about the media kit contents and Operating Environments of HP-UX 11i v1 (B.11.11). • Chapter 2, “System Requirements for Cold-Installing and Updating,” on page 31 Use this chapter to learn about the system requirements either to cold-install or update to HP-UX 11i v1. • Chapter 3, “Choosing an Installation Method,” on page 49 Use this chapter to help you decide the most appropriate method to install HP-UX 11i v1 on your system. • Chapter 4, “Preparing to Install or Update to HP-UX 11i v1,” on page 63 Use this chapter to learn the details of the required and recommended tasks to prepare your system for HP-UX 11i v1. • Chapter 5, “Cold-Installing HP-UX 11i v1,” on page 75 Use this chapter to learn how to cold-install the HP-UX 11i v1 Operating System (OS) and selected Operating Environment (OE). Alternative cold-install methods such as installing from depots or from golden images are also discussed. 14 • Chapter 6, “Updating to HP-UX 11i v1,” on page 91 Use this chapter to learn how to update your system to HP-UX 11i v1 using the update-ux command. Several examples are provided to assist you with your update scenario. • Chapter 7, “Installing HP Applications and Patches,” on page 113 Use this chapter to learn how to update applications on your system that are not installed or updated with HP-UX 11i v1 Operating Environments. • Chapter 8, “Verifying System Install or Update,” on page 119 Use this chapter to learn how to verify a successful install or update to HP-UX 11i v1. • Appendix A, “Booting HP Servers and Workstations,” on page 125 Use this appendix to learn about booting various HP servers and workstations using the built-in Boot ROM firmware interface. • Appendix B, “Known Problems and Troubleshooting,” on page 135 Use this appendix to learn about the known problems and troubleshooting steps for the install and update. • Appendix C, “HP-UX 11i v1 Software Bundles,” on page 177 Use this appendix to learn about the Operating Environments (OEs) and media contents. • Appendix D, “Configuring Built-In PCI Networking,” on page 189 Use this appendix to learn how to configure built-in (or core) PCI networking cards in HP Servers and Workstations. • Appendix E, “Controlling Memory Utilization of VxFS 3.5 on HP-UX 11i v1,” on page 197 Use this appendix to learn about the effect of two VxFS tunables, vx_ninode and vxfs_bc_bufhwm, on system memory consumption and learn about the guidelines on setting them for machines with relatively low RAM. 15 Typographical Conventions This document uses the following conventions: 16 audit (5) An HP-UX manpage. In this example, audit is the name and 5 is the section in the HP-UX Reference. On the web and on the Instant Information CD, it may be a hot link to the manpage itself. From the HP-UX command line, you can enter “man audit” or “man 5 audit” to view the manpage. See man (1). Book Title The title of a book. On the web and on the Instant Information CD, it may be a hot link to the book itself. KeyCap The name of a keyboard key. Note that Return and Enter both refer to the same key. Emphasis Text that is emphasized. Bold Text that is strongly emphasized. Bold The defined use of an important word or phrase. ComputerOut Text displayed by the computer. UserInput Commands and other text that you type. Command A command name or qualified command phrase. Variable The name of a variable that you may replace in a command or function or information in a display that represents several possible values. [ ] The contents are optional in formats and command descriptions. If the contents are a list separated by |, you must choose one of the items. { } The contents are required in formats and command descriptions. If the contents are a list separated by |, you must choose one of the items. ... The preceding element may be repeated an arbitrary number of times. | Separates items in a list of choices. HP-UX Release Name and Release Identifier Each HP-UX 11i release has an associated release name and release identifier. The uname (1) command with the -r option returns the release identifier. Table 2 lists the releases available for HP-UX 11i. Table 2 HP-UX 11i Releases Release Identifier Release Name Supported Processor Architecture B.11.11 HP-UX 11i v1 PA-RISC B.11.20 HP-UX 11i v1.5 Intel Itanium B.11.22 HP-UX 11i v1.6 Intel Itanium B.11.23 HP-UX 11i v2 PA-RISC and Intel Itanium 17 Related Documents This section discusses documentation for, and other sources of information about, HP-UX 11i v1. HP-UX 11i v1 Resources The following sources provide detailed information about HP-UX 11i v1: • HP-UX 11i v1 Instant Information CD The Instant Information CD provides HP-UX documentation supporting the release. • Manual Pages For the HP-UX 11i v1 release, the manual pages (manpages) are available on the HP-UX Welcome Page of your system, on the Instant Information CD in the HP-UX Reference document, through the use of the man command, and at the HP Technical Documentation Web site: http://docs.hp.com/hpux/os/11iv1/index.html#HP-UX%20Refe rence%20%28Manpages%29 • HP-UX Welcome Page The HP-UX Welcome Page on your HP-UX 11i v1 system contains pointers to information to help you use your HP-UX system. • Release Notes The HP-UX 11i Version 1 Release Notes describes what is new, has changed, and has been deprecated or obsoleted in the current release compared to the previous HP-UX 11i v1 release. You can find the release notes in the following locations: — HP-UX Instant Information CD. See “Media Kit Contents” on page 26 for more information. — The HP Technical Documentation Web site: http://docs.hp.com/ Here you will find the release notes pertinent to all previous releases of HP-UX, as well as release notes for various individual products. 18 • README (Read Before Installing) Documents README documents or Read Before Installing (RBI) media booklets contain information about the installation process that may not appear in this HP-UX 11i Version 1 Installation and Update Guide. Any product contained in the release may have a README document, so several README documents may be included. The Read Before Installing or Updating to HP-UX 11i Version 1 booklet is included with your media kit. The following references assume you know how to mount a DVD on your system. Files located on mounted DVD drives are referenced as dvd_mount_point, followed by the file path on the DVD media. NOTE If you plan to read the HP-UX 11i v1 DVDs on an HP-UX 11i v1 system, then you need to install the PHKL_28025 patch. The PHKL_28025 patch is in the GOLDBASE11i bundle as of June 2003, which you can find on the Support Plus media for HP-UX 11i v1 or at the IT Resource Center Web site: http://itrc.hp.com The PHKL_28025 patch supersedes PHKL_25760. • Bundle Readme Files Bundle readme files (in text and HTML formats) contain additional installation instructions, notes about problems in current and previous releases, a list of patches and their dependencies, and changes since the last release. You can print or view these files directly from the DVD, for example: more /dvd_mount_point/DOCS/PATCH/QPK1111.readme.html • Patch Text Files Patch text files for all patches are on the DVD in the /dvd_mount_point/DOCS/PATCH/TEXT_FILES directory. These files provide detailed information about the patch. Patch text files are also included with individual patches that you retrieve from HP. 19 TIP To simplify sharing of patch information, you may want to copy the documentation files onto your own system. The hyperlinks from the HTML bundle readme files to the patch text files work as long as the HTML files reside in the same directory as the TEXT_FILES subdirectory. • White Papers on HP-UX White papers associated with the HP-UX 11i v1 release are available at the HP Technical Documentation Web site: http://docs.hp.com/hpux/os/11iv1 Other white papers, including an HP-UX 11i v1 overview, can be found at the HP-UX Information Library at the HP Web site: http://www.hp.com/products1/unix/operating/infolibrary/ index.html You can find additional information about HP-UX 11i v1 at the HP Technical Documentation Web site in the HP-UX 11i v1 operating environments collection under Installing and Updating: http://www.docs.hp.com/hpux/os/11iv1/index.html#Installing%2 0and%20Updating Other documents in this collection include: • Managing Systems and Workgroups: A Guide for HP-UX System Administrators • Patch Management User Guide for HP-UX 11.x Systems • Ignite-UX Administration Guide • Software Distributor Administration Guide • Software Package Builder 1.0 User’s Guide • HP System Partitions Guide • HP-UX 11i Version 1 Reference Some or all of these documents are available on the Instant Information CD and in printed form. 20 Third-Party Resources You can find additional information about HP-UX 11i v1 in Disk and File Management Tasks on HP-UX — Prentice-Hall, Hewlett-Packard Professional Books, 1997. Other HP Web Resources The following Web sites provide a variety of information regarding the HP-UX 11i v1 release: • HP Workstations and HP 9000 Servers: — For workstations: http://www.hp.com/workstations/ — For servers: http://www.hp.com/products1/unix/operating/ • HP Software Depot: http://software.hp.com • HP Software Releases and Media: http://www.software.hp.com/RELEASES-MEDIA • Software Availability Matrix: http://software.hp.com/MATRIX • After installation of HP-UX 11iv1, all HP-specific documentation is included in the HP Apache-based Web Server software: http://yourserver.com/hp_apache_docs Or you can find it in the /opt/apache/hp_apache_docs/ directory. The latest information for the HP Apache-based Web Server is at the following Web site: http://www.hp.com/go/webserver • HP Technical Documentation feedback form: http://docs.hp.com/assistance/feedback.html • HP-UX 11i v1 documentation, including release notes, guides, and white papers: http://docs.hp.com/hpux/os/11iv1 21 • HP-UX 11i v1 information: http://forums.itrc.hp.com http://www.hp.com • Patch Management User Guide for HP-UX 11.x Systems: http://docs.hp.com • HP-UX patches and patch information from the HP IT Resource Center Web site: http://itrc.hp.com Select maintenance and support (hp products) then select the appropriate patching tools. To receive HP Security Bulletins, under maintenance and support, select subscribe to security bulletin & patch digests. • HP-UX Software Transition Kit: http://devresource.hp.com/STK • High-availability products: http://docs.hp.com/hpux/ha • Ignite-UX information and download: http://software.hp.com/products/IUX • Latest hardware support tools (diagnostics) information, including STM and EMS Hardware Monitors: http://docs.hp.com/hpux/diag • International information: http://www.hp.com Select a country or region if you are not automatically directed. • Localized user guides: http://docs.hp.com Use the navigation menu to select a language. • Safety and ergonomic information: http://www.hp.com/ergo • 22 Servicecontrol Manager: http://software.hp.com/products/SCMGR • Software Distributor: http://software.hp.com/products/SD_AT_HP • Support Plus Web site: http://software.hp.com/SUPPORT_PLUS • System administration for HP-UX systems: http://docs.hp.com/hpux/os/11iv1 http://forums.itrc.hp.com • System firmware: http://docs.hp.com/hpux/hw/index.html#System%20Firmware 23 HP Encourages Your Comments HP encourages your comments concerning this document. We are truly committed to providing documentation that meets your needs. Please send comments to: http://docs.hp.com/assistance/feedback.html Please include document title, manufacturing part number, and any comment, error found, or suggestion for improvement you have concerning this document. Also, please include what we did right so we can incorporate it into other documents. 24 1 Welcome to HP-UX 11i Version 1 HP-UX 11i Version 1, for the PA-RISC architecture, offers a full range of HP-UX Operating Environments (OEs), including systems management and high-availability software products. This chapter introduces you to the media kit contents and Operating Environments of HP-UX 11i Version 1 (B.11.11). The HP-UX 11i v1 OEs are integrated and tested software solutions containing the operating system and selected applications. What You Will Find in This Chapter Chapter 1 • “Media Kit Contents” on page 26 • “HP-UX 11i v1 Operating Environments” on page 28 • “The Next Step” on page 30 25 Welcome to HP-UX 11i Version 1 Media Kit Contents Media Kit Contents This guide is part of the HP-UX 11i v1 media kit, which includes the following CDs, DVDs, and documents: • HP-UX 11i v1 (B.11.11) DVD — Contains the HP-UX Operating System (OS), Operating Environments (OEs), required networking software, Update-UX, Ignite-UX, and online diagnostics. • HP-UX 11i v1 Support Plus CD — Contains the current HP-UX 11i v1 patch bundles and OnlineDiag bundle to fix defects and enable new hardware. • HP-UX 11i v1 (B.11.11) Applications DVD — Contains HP-UX application software. • HP-UX 11i v1 Instant Information CD — Contains HP-UX manuals, release notes, and white papers. See the CD booklet for more information. • HP-UX 11i v1 Internet Express DVD — Contains a collection of Open Source Web, Internet, and security services that have been tested and qualified on HP-UX. • Read Before Installing or Updating to HP-UX 11i Version 1 — Provides last-minute information for HP-UX 11i v1. Read this booklet before cold-installing or updating HP-UX. The booklet is also available at the HP Technical Documentation Web site: http://docs.hp.com/hpux/os/11iv1 • HP-UX 11i Version 1 Release Notes — Describes new features and functionality changes for HP-UX 11i v1. Release Notes are available on the Instant Information CD and at the HP Technical Documentation Web site: http://docs.hp.com/hpux/os/11iv1 • HP-UX 11i Version 1 Installation and Update Guide (this document) — Describes the media kit and instructions to cold-install or update to the latest release of HP-UX. The guide is also available at the HP Technical Documentation Web site: http://docs.hp.com/hpux/os/11iv1 26 Chapter 1 Welcome to HP-UX 11i Version 1 Media Kit Contents NOTE If you plan to read the HP-UX 11i v1 DVDs on an HP-UX 11i v1 system, or to cold-install HP-UX 11i v1 from a depot on an HP-UX 11i v1 system, then you need to install the PHKL_28025 patch. See “Problems Reading HP-UX 11i v1 DVD Media” on page 160 for information on mounting the HP-UX 11i v1 DVD. The PHKL_28025 patch is in the GOLDBASE11i bundle as of June 2003, which you can find on the Support Plus media for HP-UX 11i v1 or at the IT Resource Center Web site: http://itrc.hp.com The PHKL_28025 patch supersedes PHKL_25760. Chapter 1 27 Welcome to HP-UX 11i Version 1 HP-UX 11i v1 Operating Environments HP-UX 11i v1 Operating Environments Operating Environments (OEs) are tested and integrated application bundles designed to work with the operating system and provide the functionality needed for your system’s purpose. The following OEs are included on the HP-UX 11i v1 (B.11.11) DVD: • HP-UX 11i v1 Foundation OE (FOE) — Designed for the demands of Web servers, content servers, and front-end servers, this OE includes applications such as HP-UX Web Server Suite, Java 2 Standard Edition technology, and Mozilla Application Suite. This OE is bundled as HPUX11i-OE. • HP-UX 11i v1 Enterprise OE (EOE) — Designed for database application servers and logic servers, this OE contains the HP-UX 11i v1 Foundation OE bundles and additional applications such as GlancePlus Pak to enable an enterprise-level server. This OE is bundled as HPUX11i-OE-Ent. • HP-UX 11i v1 Mission Critical OE (MCOE) — Designed for the large, powerful, back-end application servers and database servers that access customer files and handle transaction processing, this OE contains the Enterprise OE bundles, plus applications such as HP Serviceguard and Workload Manager to enable a mission-critical server. This OE is bundled as HPUX11i-OE-MC. • HP-UX 11i v1 Minimal Technical OE (MTOE) — Designed for workstations running HP-UX 11i v1, this OE includes the Mozilla Application Suite, Perl, VxVM, and Judy applications, plus the OpenGL Graphics Developer’s Kit. This OE is bundled as HPUX11i-MTOE. • HP-UX 11i v1 Technical Computing OE (TCOE) — Designed for both compute-intensive workstation and server applications, this OE contains the MTOE bundles plus extensive graphics applications and Math Libraries. This OE is bundled as HPUX11i-TCOE. For more information about the contents of the Operating Environments, see Appendix C, “HP-UX 11i v1 Software Bundles,” on page 177. 28 Chapter 1 Welcome to HP-UX 11i Version 1 HP-UX 11i v1 Operating Environments Table 1-1 details the supported Operating Environments for HP servers and workstations: Table 1-1 Supported Operating Environments HP Commercial Servers HP Workstations Chapter 1 FOE EOE MCOE X X X MTOE TCOE X X X 29 Welcome to HP-UX 11i Version 1 The Next Step The Next Step Continue with Chapter 2, “System Requirements for Cold-Installing and Updating,” on page 31. 30 Chapter 1 2 System Requirements for Cold-Installing and Updating This chapter helps you assess the current state of your system prior to cold-installing or updating to HP-UX 11i v1. What You Will Find in This Chapter IMPORTANT • “System Requirements” on page 32 • “How to Plan Your Disk Space Needs” on page 33 • “Supported Servers and Workstations” on page 36 • “Unsupported Servers and Workstations” on page 42 • “Supported Network Drivers, Mass Storage Drivers, and SCSI Devices” on page 43 • “Supported Firmware” on page 44 • “Identification of Model, OS/OE, and Software” on page 45 • “The Next Step” on page 47 Review the Read Before Installing or Updating to HP-UX 11i v1 DVD booklet. It describes last-minute information that was not available when this guide was published. Time Estimate for This Chapter: Approximately 1 hour to compare the system requirements in this chapter with your system. Chapter 2 31 System Requirements for Cold-Installing and Updating System Requirements System Requirements For cold-install or update to HP-UX 11i v1, you need the following: NOTE 32 • A supported system. See “Supported Servers and Workstations” on page 36. • HP-UX 11i v1 OE and Application (AR) media (a two-DVD set) • 1 GB memory, minimum • 1 GB swap space, minimum If your system has less than 1 GB of memory, you may need to manually set VxFS tunables for optimal performance after cold-installing or updating to HP-UX 11i v1. For more information about these tunables, see Appendix E, “Controlling Memory Utilization of VxFS 3.5 on HP-UX 11i v1,” on page 197. Chapter 2 System Requirements for Cold-Installing and Updating How to Plan Your Disk Space Needs How to Plan Your Disk Space Needs This section provides hints and information to help you determine your disk needs for HP-UX 11i v1. If you need more disk space, be sure to order the equipment and plan on installing it after backing up your current system. • • Record the hardware path to the DVD drive. Develop a clear configuration plan, including: — — — — — • • File system sizes Swap space size Dump device Disk and file system parameters Mirroring information If installing application programs other than those supplied within an HP-UX 11i v1 Operating Environment (OE), consider the vendor’s size recommendations. When planning disk space, refer to these documents: — Managing Systems and Workgroups: A Guide for HP-UX System Administrators — This manual is available on the Instant Information CD and at the HP Technical Documentation Web site: http://docs.hp.com — Disk and File Management Tasks on HP-UX — Prentice-Hall, Hewlett-Packard Professional Books, 1997. Disk Space Allocation for File Partitions Depending on your system’s purpose, you may need to determine how much disk space you will need for each file partition before you cold-install or update to HP-UX 11i v1. For example, if you plan to install applications from other vendors, you may need to modify the size of the /opt partition to accommodate their size. Chapter 2 33 System Requirements for Cold-Installing and Updating How to Plan Your Disk Space Needs Disk Space Requirements for a Cold-Install Table 2-1 lists the amount of disk space allocated for the indicated partitions during a default cold-install for each Operating Environment. (The percentage used in each partition is in parentheses.) Table 2-1 Partition File Partition Disk Space Allocation by Operating Environment1 FOE EOE MCOE TCOE MTOE / 208 MB (78% used) 208 MB (81% used) 208 MB (81% used) 208 MB (77% used) 223 MB (83% used) /stand 304 MB (21% used) 304 MB (21% used) 304 MB (21% used) 304 MB (21% used) 300 MB (23% used) /var 4.5 GB (2% used) 4.5 GB (2% used) 4.5 GB (2% used) 4.5 GB (2% used) 1.5 GB (6% used) /usr 2.6 GB (76% used) 2.7 GB (75% used) 2.7 GB (75% used) 3.7 GB (61% used) 3.7 GB (62% used) /tmp 208 MB (4% used) 208 MB (4% used) 208 MB (4% used) 208 MB (4% used) 200 MB (4% used) /opt 3.6 GB (52% used) 3.7 GB (53% used) 3.7 GB (53% used) 4.5 GB (58% used) 2.7 GB (63% used) /home 32 MB (26% used) 32 MB (26% used) 32 MB (26% used) 32 MB (26% used) 20 MB (41% used) Total2 11.5 GB (37% used) 11.7 GB (37% used) 11.7 GB (36% used) 13.5 GB (38% used) 8.7 GB (50% used) 1. The results are from using the bdf (1M) command; your results may vary if you use the du (1) command. 2. Totals are not exact due to rounding. Depending on how much disk space is available, you can change the partition size to meet your needs. For information about modifying your file system, refer to Managing Systems and Workgroups: A Guide for HP-UX System Administrators at the HP Technical Documentation Web site: http://docs.hp.com 34 Chapter 2 System Requirements for Cold-Installing and Updating How to Plan Your Disk Space Needs Disk Space Requirements for an Update To ensure a successful update to HP-UX 11i v1, make sure that you have at least as much disk space allocated to the file partitions listed in Table 2-1 on page 34, and that each partition (most importantly, /usr, /opt, and /var) has at least 10-20 percent free space to allow for any growth. Additionally, make sure that you have at least 1 GB allocated for /swap. Extra Space Cold-installing or updating the HP-UX 11i v1 Technical Computing OE Needed with TCOE (TCOE) and the Minimal Technical OE (MTOE) installs all CDE and MTOE languages rather than just a selected language. To remove unneeded CDE language bundles after installing the TCOE or MTOE, list them using swlist and remove unneeded bundles using swremove. You can also choose to deselect unneeded bundles during the installation process. For information on how to deselect software bundles that are installed by default during a cold-install, see “Task 4: Deselecting OE Software Bundles” on page 84. For information on how to deselect software bundles that are installed by default during an update, see “Task 3: Using update-ux (Required)” on page 102. See Chapter 8, “Verifying System Install or Update,” on page 119 for examples of swlist and swremove. Refer to the HP-UX 11i v1 Release Notes for software dependencies: http://docs.hp.com/hpux/os/11iv1/index.html Chapter 2 35 System Requirements for Cold-Installing and Updating Supported Servers and Workstations Supported Servers and Workstations The following tables outline the supported HP-UX 11i v1 configurations for HP servers and workstations. NOTE The following table includes servers that have been discontinued; that is, they are no longer sold, but are still supported, as of the time of this writing. The table does not list servers that have been obsoleted1, nor does it list servers that may have been added after this document was developed. For the most up-to-date information about the support of HP-UX 11i v1 on older servers, as well as the most recently supported servers, consult your HP Sales Representative. For further information about HP servers, workstations, and systems hardware, see the HP documentation Web site at http://docs.hp.com/hpux/hw/. 1. “Obsoleted” means that the server has been discontinued (it is no longer sold) and is no longer supported by HP. 36 Chapter 2 System Requirements for Cold-Installing and Updating Supported Servers and Workstations Supported HP Servers Table 2-2 outlines the supported HP-UX 11i v1 configurations for HP servers. Table 2-2 Bezel or Model A-Class: A180, A180C Supported Servers 32-bit Support D-Class: D270, D280, D370, D380, D390 A180/A180C discontinued February 1, 2001. 3 bp2200 blade (in an HP bh3710 chassis) 3 A400/A500 discontinued September 1, 2002. HP-UX model string: 900/800/HPServerBlade8600/3xx2 PA-7xxx D220/D230 discontinued June 1, 2000. D320 discontinued September 1, 2001, and D330 discontinued February 1, 2001. 3 PA-8xxx 3 3 D270/D280/D370 discontinued June 1, 2000. D380 discontinued November 1, 2000, and D390 discontinued September 1, 2001. Kx20: PA-7200LC processor All other K-Class servers: PA-8xxx 3 Chapter 2 PA-8500 and newer processors PA-8600 processor only K-Class: Kx20, Kx70, Kx80, K250, K360, K450, K460 L-Class: L1000, L2000 Comments PA-7300LC 3 A-Class: A400, A500 D-Class: D220, D230, D320, D330 64-bit Support 3 3 Kx20 discontinued September 1999. Kx70 discontinued November 1, 2000. Kx80 discontinued September 1, 2001. K250/K450 discontinued December 1, 2000. K360/K460 discontinued June 1, 2000. PA-8500 and newer processors L1000/L2000 discontinued May 1, 2002. 37 System Requirements for Cold-Installing and Updating Supported Servers and Workstations Table 2-2 Bezel or Model Supported Servers (Continued) 32-bit Support L-Class: L1500, L3000 3 N-Class: N4000 R-Class: R380, R390 64-bit Support 3 Comments PA-8600 and newer processors L1500/L3000 discontinued January 1, 2004. PA-8500 and newer processors Discontinued April 25, 2003. PA-8000 and newer processors 3 3 rp2400 R380 discontinued August 1, 2000. R390 discontinued September 1, 2001. PA-8500 processor 3 HP-UX model string: A400-44 Discontinued September 1, 2002. rp2405/rp2405-2 3 rp2430/rp2430-1 PA-8700 processor Discontinued November 1, 2004. PA-8700 processor 3 HP-UX model string: A400-6X Discontinued November 1, 2004. rp2450 PA-8500 and newer processors 3 HP-UX model string: A500-44 or A500-5X Discontinued September 1, 2002. rp2470/rp2470-2 PA-8700 processors 3 HP-UX model string: A500-6X or A500-7X Discontinued November 1, 2004. rp3410/rp3410-2 3 PA-8800 processors rp3440/rp3440-4 3 PA-8800 and newer processors rp4440/rp4440-8 3 PA-8800 and newer processors 38 Chapter 2 System Requirements for Cold-Installing and Updating Supported Servers and Workstations Table 2-2 Bezel or Model Supported Servers (Continued) 32-bit Support 64-bit Support rp5400 Comments PA-8500 and PA-8600 processors 3 HP-UX model string: L1000-36, -44, -5X Discontinued May 1, 2002. rp5405/rp5405-4 3 rp5430 PA-8700 processors HP-UX model string: L3000-6X PA-8600 and newer processors 3 HP-UX model string: L1500-5X, -6X, -7X, or -8X Discontinued July 1, 2004. rp5450 PA-8500 and PA-8600 processors 3 HP-UX model string: L2000-36, -44, -5X Discontinued May 1, 2002. rp5470/rp5470-4 PA-8600 and newer processors 3 HP-UX model string: L3000-5X, -6X, -7X, or -8X Discontinued July 1, 2004. rp7400 PA-8500 processors 3 HP-UX model string: N4000-65 or N4000-75 Discontinued February 1, 2003. rp7405/rp7405-8 and rp7410/rp7410-8 3 rp7420/rp7420-16 3 Chapter 2 PA-8700 processor HP-UX model string: 9000/800/rp7410 (both rp7405 and rp7410) PA-8800 and newer processors 39 System Requirements for Cold-Installing and Updating Supported Servers and Workstations Table 2-2 Bezel or Model Supported Servers (Continued) 32-bit Support 64-bit Support rp8400/rp8400-16 Comments PA-8700 and newer processors 3 HP-UX model string: S16K-A rp8420/rp8420-32 3 PA-8800 and newer processors Superdome SD16 3 HP-UX model string: 9000/800/S16000 Superdome SD16A 3 HP-UX model string: 9000/800/SD16A Superdome SD32 3 HP-UX model string: 9000/800/S32000 Superdome SD32A 3 HP-UX model string: 9000/800/SD32A Superdome SD64 3 HP-UX model string: 9000/800/S64000 Superdome SD64A 3 HP-UX model string: 9000/800/SD64A T-Class: T600 V-Class: V2200, V2250, V2500, V2600 40 3 3 PA-8xxx Discontinued August 1, 1999. PA-8200 and newer processors 3 V2200 discontinued September 1999. V2250 discontinued July 1, 2000. V2500 discontinued January 1, 2001. V2600 discontinued December 1, 2001. Chapter 2 System Requirements for Cold-Installing and Updating Supported Servers and Workstations Supported HP Workstations Table 2-3 outlines the supported HP-UX 11i v1 configurations for HP workstations. Table 2-3 Supported Workstations Model(s) 32-bit Support 64-bit Support Comments Series 700: PA-7xxx 3 All 712, 715/64/80/100/100XC, 725/100, 743, 744, 745, 748i, 748 B-Class: PA-7300LC 3 B132L, B132L+, B160L, B180L B-Class: PA-8500 and forward 3 Bx000 B-Class: PA-8600 3 B2600 C-Class: PA-7xxx 3 C-Class: PA-8xxx 3 C100, C110, C160L 3 C160, C180, C180-XP,C200, C240, C360 C-Class: PA-8500 and forward 3 C3x00 C-Class: PA-8700 and forward 3 C3650, C3700, C3750 C-Class: PA-8800 3 C8000 J-Class: PA-7xxx 3 J-Class: PA-8000/8200 3 J200, J210, J210XC 3 J280, J282, J2240 J-Class: PA-8500 and forward 3 J5x00, J6000, J7000 J-Class: PA-8700 and forward 3 J6700, J6750 Chapter 2 41 System Requirements for Cold-Installing and Updating Unsupported Servers and Workstations Unsupported Servers and Workstations The following HP servers, HP workstations, and HP graphics adapters are no longer supported: • Servers: E-, F-, G-, H-, and I-Class • Workstations: 705, 710, 715/33, 715/50, 715/75, 720, 725/50, 725/75, 730, 735, 750,755 • Graphics adapters: GRX, CRX, CRX-24, CRX-48Z NOTE C3700 and J6700 workstations require PA-8700 processor board upgrades (to version 2.3) to support HP-UX 11i v1. Contact your HP Customer Engineer for more details. NOTE As of the September 2002 HP-UX 11i v1 release, HP 3D Graphics are no longer supported on PA-RISC systems older than version 2.0. If you have an older PA-RISC workstation and need 3D Graphics, HP recommends that you do not install or update to this release of the Technical Computing Operating Environment (TCOE) or Minimal Computing Operating Environment (MCOE). 42 Chapter 2 System Requirements for Cold-Installing and Updating Supported Network Drivers, Mass Storage Drivers, and SCSI Devices Supported Network Drivers, Mass Storage Drivers, and SCSI Devices For a complete list of supported network drivers, mass storage drivers, and SCSI devices, refer to the HP-UX 11i Version 1 Release Notes at the HP Technical Documentation Web site: http://docs.hp.com/hpux/os/11iv1/index.html NOTE Chapter 2 Installing or updating to HP-UX 11i v1 installs a minimum set of default networking drivers that apply to the system. You may need to select or specify other available networking drivers to enable other cards on your system. This can easily be done during install or update by following the instructions for your selected migration path. 43 System Requirements for Cold-Installing and Updating Supported Firmware Supported Firmware Firmware changes frequently. Make sure your system has the latest firmware installed to support, for example, the latest versions of I/O adapters, mass storage devices, and devices used when you install from media or a network depot. • For the latest HP-UX 11.x firmware updates, go to the IT Resource Center (ITRC) Web site: http://itrc.hp.com Log in to your appropriate region. Click maintenance and support (hp products), then find individual patches and firmware. If you have to patch your firmware, the ITRC provides a patch database to search and instructions in the patch documentation on how to patch the firmware. HP also provides the Subscriber’s Choice. You can sign up to receive email notices for firmware updates. • For firmware revisions needed for HP-UX boot support on I/O adapters, go to the HP Technical Documentation Web site: http://docs.hp.com/hpux/hw/index.html#System%20Firmware • For the latest firmware documentation, go to the HP Technical Documentation Web site and search for firmware: http://docs.hp.com 44 Chapter 2 System Requirements for Cold-Installing and Updating Identification of Model, OS/OE, and Software Identification of Model, OS/OE, and Software Before you cold-install or update to HP-UX 11i v1, you need to identify the model of your system and other information. Identifying the Model To determine the model number of your system, enter: model To verify that HP-UX 11i v1 is supported on your system, see “Supported Servers and Workstations” on page 36. Identifying the OS To identify the OS version that your system is currently running, enter: uname -r When a system has HP-UX 11i v1 installed, you can determine which revision (Release ID) is installed by entering the following command: /usr/sbin/swlist -l bundle The HPUXBaseAux bundle indicates the current installed revision level. The revision level is indicated both in the bundle version number and in the description text. Identifying the OE To identify the Operating Environment currently installed on your system, use swlist. For example: /usr/sbin/swlist The output of this command includes a line that identifies the installed OE. For example: HPUX11i-OE B.11.11 HP-UX 11i Operating Environment Component Chapter 2 45 System Requirements for Cold-Installing and Updating Identification of Model, OS/OE, and Software Identifying Installed Software To identify the software products on a system or media, use swlist. For example, to show revision and descriptive title of all software installed on a system, enter: /usr/sbin/swlist To list all products and their versions on a DVD mounted at /dvdrom, enter: /usr/sbin/swlist -s /dvdrom To get a table of contents and product details, enter: /usr/sbin/swlist -dvl product -a readme @ /dvdrom The swlist command has many options to expand or narrow the listing to specific attributes. Refer to the swlist (1M) manpage or the Software Distributor Administration Guide, available on the Instant Information CD and at the HP Technical Documentation Web site: http://docs.hp.com/hpux/os/11iv1 46 Chapter 2 System Requirements for Cold-Installing and Updating The Next Step The Next Step Continue with Chapter 3, “Choosing an Installation Method,” on page 49. Chapter 2 47 System Requirements for Cold-Installing and Updating The Next Step 48 Chapter 2 3 Choosing an Installation Method This chapter provides information and scenarios to help you choose the most appropriate method to install HP-UX 11i v1 on your system. What You Will Find in This Chapter • “Supported Cold-Install Paths to HP-UX 11i v1” on page 50 • “Supported Update Paths to HP-UX 11i v1” on page 51 • “Deciding Which Method to Use” on page 53 • “If You Have an Existing HP-UX 11i v1 System” on page 58 • “Standard HP-UX Bundle Considerations” on page 59 • “Online Diagnostics” on page 60 • “The Next Step” on page 61 Time Estimate for This Chapter: Approximately 1 hour to read about the cold-install and update paths, and to choose a method. NOTE Chapter 3 For customers ordering new systems with the Instant Ignition option (also known as factory integrated), the cold-installation process described here has already been performed. Skip this chapter and proceed to installing applications and patching software. See Chapter 7, “Installing HP Applications and Patches,” on page 113. 49 Choosing an Installation Method Supported Cold-Install Paths to HP-UX 11i v1 Supported Cold-Install Paths to HP-UX 11i v1 Cold-install means installing system software on a new (un-installed) or existing system by completely rebuilding the volume group, erasing the existing operating system and data on that volume, and installing the new operating system and specified software and data. An advantage of cold-install is that supported software can be installed without regard for the software currently on the system, or concern for cleaning up old software. You can cold-install HP-UX 11i v1 and its accompanying Operating Environment on any supported system listed in “Supported Servers and Workstations” on page 36. You can cold-install on any supported system from the following HP-UX operating systems: NOTE 50 • HP-UX 9.x • HP-UX 10.01 • HP-UX 10.10 • HP-UX 10.20 • HP-UX 10.30 • HP-UX 11.0 • HP-UX 11.10 • HP-UX 11i v1 If your system already is running any version of the HP Apache-based Web Server, installing or updating to an HP-UX 11i v1 Operating Environment will install the version of HP-UX Web Server Suite included with the HP-UX 11i v1 OE. Refer to the HP-UX 11i v1 Release Notes for more information. Chapter 3 Choosing an Installation Method Supported Update Paths to HP-UX 11i v1 Supported Update Paths to HP-UX 11i v1 Update means using the update-ux command and Software Distributor (SD) tools to selectively overwrite the operating system and application software from a media or network source depot. An advantage of performing an update is that it leaves user data, configuration, and applications in place. You can update to HP-UX 11i v1 from the following HP-UX operating systems: • HP-UX 10.20 • HP-UX 11.0 • HP-UX 11i v1 If you update an existing HP-UX OS to the December 2004 version of HP-UX 11i v1, the system must be running either HP-UX 10.20 or HP-UX 11.0. Updating from any other release to HP-UX 11i v1 is not supported. Table 3-1 lists the supported update paths from previous releases of HP-UX to the current release of HP-UX 11i v1. Table 3-1 From Chapter 3 Updating from Previous HP-UX Releases To This HP-UX 11i v1 Release With or Without an Operating Environment HP-UX 9.x, 10.01, or 10.10 Update to HP-UX 10.20 before updating to HP-UX 11i v1 HP-UX 10.20 Update to HP-UX 11i v1 HP-UX 10.30 Update to HP-UX 11.0 before updating to HP-UX 11i v1 HP-UX 11.0 Update to HP-UX 11i v1 HP-UX 11.10 Update is not supported HP-UX 11i v1 Update to HP-UX 11i v1 OS or OE. or both 51 Choosing an Installation Method Supported Update Paths to HP-UX 11i v1 NOTE If you attempt to update from this release (HP-UX 11i v1 December 2004) to the HP-UX 11i v2 September 2004 release, the update process will stop and you will get the following message: ERROR: Updating from the newer 11i v1 December 2004 Update Release to the earlier 11i v2 September 2004 Update Release is not supported. See latest 11i v1 Install/Update Guide for more information. What To Do HP supports the following HP-UX 11i v2 (B.11.23) cold-install and update paths for this release: 52 • You can cold-install the September 2004 HP-UX 11i v2 (B.11.23) release. • You can update from HP-UX 11i v1 (B.11.11) June 2004 and earlier HP-UX 11i v1 releases to the September 2004 HP-UX 11i v2 release. Chapter 3 Choosing an Installation Method Deciding Which Method to Use Deciding Which Method to Use Now that you have evaluated your system and ordered any needed hardware, you need to decide whether to cold-install or update to HP-UX 11i v1 on your system. The process described in this guide cold-installs and updates a single system from local media. • If you are cold-installing or updating one system at a time — Cold-install or update directly from the CDs or DVDs in the HP-UX 11i v1 media kit: — HP-UX 11i v1 OE media (2 CDs or 1 DVD) — Boot and install a new system or update an existing system. — Support Plus CD — Install current HP-UX 11i v1 patch bundles and OnlineDiag bundle to fix defects and enable new hardware. — HP-UX Application media (multiple CDs or 1 DVD) — Install applications not installed with the OE or install a newer version of an OE application. • If you plan to cold-install or update on many systems in your enterprise — You can use an Ignite-UX server to cold-install or update using one of the following methods: — Golden Image — Create a golden image from which to cold-install. A golden image is a snapshot of a known, good operating system installation and configuration for use in installing other clients. The copied (source) client is called the golden image. This install image can contain the OS and OE, other applications, and any needed patches. After the archive is in place, either on the Ignite-UX server or on another system, cold-install on each client system in a single-pass operation; you need to reboot each client only once. — Network Depot — Use Software Distributor (SD) commands to create depots containing OS, OE, and other software bundles, then install from the depot using Ignite-UX. For help with this method, refer to the swinstall (1M) manpage, the Software Distributor Administration Guide, and the Ignite-UX Administration Guide. Chapter 3 53 Choosing an Installation Method Deciding Which Method to Use For details on installing an Ignite-UX server, refer to the Ignite-UX Administration Guide supplied on the Instant Information CD and at the HP Technical Documentation Web site: http://docs.hp.com/hpux/os/11iv1 When to Cold-Install CAUTION The cold-install process erases software on the root volume before installing HP-UX 11i v1. If you want to retain any existing software, make sure to back up that software before migrating or use update. Cold-installing using Ignite-UX overwrites everything on the target disk. You can cold-install rather than update to HP-UX 11i v1 when: • You have a new system. • You are managing several systems with similar OS configurations. • Your disk space needs reconfiguration. See “How to Plan Your Disk Space Needs” on page 33. • Your systems are organized with clean separation of the OS from user, application, and data files. • Overwriting the root (/) volume on existing systems will not cause a loss of applications or data. • Your system configuration is not listed as a supported update path. See “Supported Update Paths to HP-UX 11i v1” on page 51. You can cold-install from any supported configuration. See “Supported Servers and Workstations” on page 36. See Chapter 4, “Preparing to Install or Update to HP-UX 11i v1,” on page 63 for more information about preparing your system for cold-install and then read the cold-install process using Ignite-UX in Chapter 5, “Cold-Installing HP-UX 11i v1,” on page 75. 54 Chapter 3 Choosing an Installation Method Deciding Which Method to Use When to Update You can update rather than cold-install HP-UX 11i v1 when: IMPORTANT • You are updating from a supported HP-UX 10.20, HP-UX 11.0, and HP-UX 11i v1 system. See “Supported Update Paths to HP-UX 11i v1” on page 51 for specific details. • You are concerned about recovering unique applications and data on your root volume, and do not want to write over non-OS files, which occurs when cold-installing HP-UX 11i v1. • Each system has a unique configuration. • Current disk space is sufficient for HP-UX 11i v1. See “How to Plan Your Disk Space Needs” on page 33. If /stand is not of sufficient size, the partition can be resized, requiring the root disk to be reformatted. In this case, you must cold-install rather than update your system. To determine whether /stand is large enough to support this release of HP-UX 11i v1, see “Disk Space Requirements for a Cold-Install” on page 34. This installation method uses the update-ux command and Software Distributor (SD) tools to selectively overwrite the operating system and application software from media or a network source depot. An advantage of performing an update is that it leaves user data, configuration, and applications in place. Updating to HP-UX 11i v1 is limited to the supported paths listed in “Supported Update Paths to HP-UX 11i v1” on page 51. See Chapter 4, “Preparing to Install or Update to HP-UX 11i v1,” on page 63 for details on how to prepare your system to update to HP-UX 11i v1. The update process is described in Chapter 6, “Updating to HP-UX 11i v1,” on page 91. Chapter 3 55 Choosing an Installation Method Deciding Which Method to Use Additional Cold-Install Considerations The following sections provide additional information to assist you in deciding whether to cold-install HP-UX 11i v1. Using VxVM Rootability Ignite-UX now provides you the option to install and configure VxVM 3.5 on your root volume. If you plan to configure your root volume with VxVM 3.5, make sure you read the supporting VxVM 3.5 documentation included on the Instant Information CD. Cold-Installing on Partitioned Systems HP-UX must be installed on the boot disk assigned to each partition after the partition has been configured. Configuring the boot disk is explained in the HP System Partitions Guide manual, available on the HP-UX 11i v1 Instant Information CD and at the HP Technical Documentation Web site: http://docs.hp.com 56 Chapter 3 Choosing an Installation Method Deciding Which Method to Use Additional Update Considerations The following sections provide additional information to assist you in deciding whether to update to HP-UX 11i v1. Updating to 64-bit OS update-ux defaults to the OS word-width that your system is currently running. For example, if the target system is running 32-bit OS, this will be the default for the new OS to be installed. For information on how to override the default, refer to the update-ux (1M) manpage. Update-UX Contains a Default-Installed Selection File The Update-UX product includes a default selections file, update-ux.selections, which is installed in /usr/lib/sw. This file provides a list of bundles that are selected for install during an OS update. Update-UX provides support for the -f selection_file option on the update-ux command line. With this option you can create your own selections file and specify that your file be used in place of the default selections file. This provides you with the flexibility to deselect any bundles listed in the update-ux.selections file by providing your own file, which does not contain these bundles. To do this, you must first install the March 2004 version or later version of the Update-UX product onto your target system, then copy and edit the /usr/lib/sw/update-ux.selections file as desired. When executing Update-UX, your custom selections file can be specified on the update-ux command line via the -f selection_file option. VxVM Rootability Not Enabled with update-ux With the September 2002 release of HP-UX 11i v1, you cannot enable VxVM rootability through the update process using update-ux. If you want to manage your root volume with VxVM, you can choose to enable rootability in either of the following ways: Chapter 3 • Cold-installing HP-UX 11i v1. See “Using VxVM Rootability” on page 56. • Using the VxVM conversion tools provided in the Base-VXVM and FEATURE11-11 bundles that are installed with HP-UX 11i v1. For more information, refer to the VERITAS Volume Manager 3.5 Release Notes and VERITAS Volume Manager 3.5 Administrator’s Guide on the Instant Information CD. 57 Choosing an Installation Method If You Have an Existing HP-UX 11i v1 System If You Have an Existing HP-UX 11i v1 System If your system is already running HP-UX 11i v1, you may only want to install one or more patch bundles to proactively address defects or to enable new hardware. If you only install the patch bundles, these bundles will not include the application updates provided on the OE media. Rather than doing a complete migration to the current HP-UX 11i v1 OS or OE, consider using swinstall to install the latest patch bundles (Table 3-2) to meet your system needs: Table 3-2 Patch Bundle HWEnable11i GOLDBASE11i GOLDAPPS11i December 2004 Patch Bundles (by Media Location) Description HP-UX 11i v1 OE Media SupportPlus1 Enables new hardware and delivers critical patches for HP-UX 11i v1 systems X X Fixes defects for HP-UX 11i v1 OS and network drivers included in OEs X2 Fixes defects for HP-UX 11i v1 OE applications X2 1. Support Plus bundles are available on a biannual basis via CD and the Web. For more details and to download recent bundles, go to this Web site: http://software.hp.com/SUPPORT_PLUS/ 2. These bundles contain patches with the highest ratings from tests in the HP Enterprise Patch Test Center. For instructions on installing patch bundles on an existing HP-UX 11i v1 system, see Chapter 6, “Updating to HP-UX 11i v1,” on page 91. 58 Chapter 3 Choosing an Installation Method Standard HP-UX Bundle Considerations Standard HP-UX Bundle Considerations Standard HP-UX bundles supply diagnostics and patches for HP-UX core files, applications, and diagnostic products. These bundles enable new hardware, fix known defects, and provide diagnostics tools. In some cases, a patch may deliver new software functionality. All bundle software is cumulative and replaces completely any previous bundle release for the same operating system (OS) release. See Appendix C, “HP-UX 11i v1 Software Bundles,” on page 177 for a listing of the always-installed, default-installed, and selectable software bundles. Patch Management Resources The Patch Management User Guide for HP-UX 11.x Systems provides information and procedures on how to acquire and install standard HP-UX patch bundles, including the HWE and Quality Pack (QPK) bundles. Go to the HP Technical Documentation Web site: http://docs.hp.com/hpux/os/11iv1 Chapter 3 59 Choosing an Installation Method Online Diagnostics Online Diagnostics HP-UX 11i v1 automatically installs diagnostics on all systems to provide required hardware support. These tools, contained in the OnlineDiag bundle, give you a complete solution to verify, troubleshoot, and monitor Itanium-based system hardware, including CPUs, memory, interface cards, and mass storage and other devices. CAUTION Uninstalling the OnlineDiag bundle prevents products with dependencies on the diagnostics from functioning correctly. Not installing OnlineDiag removes protections against hardware failures that diagnostics provide. Without the tools, it is much harder to troubleshoot and fix problems if a hardware failure occurs. To ensure the reliability of your computer system, HP highly recommends installing the OnlineDiag bundle with HP-UX 11i v1. With a media install, the OnlineDiag bundle is default installed with any HP-UX 11i Operating Environment. The tools in OnlineDiag: • Protect you against some hardware failures, for example, some memory problems. • Provide EMS hardware monitors that notify you of hardware events that may indicate impending hardware failure. • Maintain logs that can give you critical help in determining the cause of failures. • Enable you to troubleshoot system problems with the system online or offline. For most computer systems, no special configuration of the diagnostics is necessary. For complete information, go to the Diagnostics Web site: http://docs.hp.com/hpux/diag 60 Chapter 3 Choosing an Installation Method The Next Step The Next Step After deciding which method to use to install HP-UX 11i v1, you can start preparing your system for either cold-install or update. Proceed to Chapter 4, “Preparing to Install or Update to HP-UX 11i v1,” on page 63. IMPORTANT Chapter 3 Make sure you review the Read Before Installing or Updating to HP-UX 11i v1 DVD booklet for situations not discussed in Chapter 3, “Choosing an Installation Method,” on page 49 that may apply to your system. 61 Choosing an Installation Method The Next Step 62 Chapter 3 4 Preparing to Install or Update to HP-UX 11i v1 This chapter details the preparation tasks required to cold-install or update to HP-UX 11i v1. What You Will Find in This Chapter • “Cold-Install Tasks” on page 64 • “Update Tasks” on page 67 • “Backing Up Your System” on page 69 • “Locating Source Media and Codewords” on page 72 • “The Next Step” on page 74 Time Estimate for This Chapter: Approximately 2 hours to gather the information needed and perform the prescribed tasks. Chapter 4 63 Preparing to Install or Update to HP-UX 11i v1 Cold-Install Tasks Cold-Install Tasks Prior to cold-installing HP-UX 11i v1, perform these tasks: • Back up any configuration files you want to reinstall. • Back up your system using any supported HP-UX backup software. • If you intend to cold-install HP-UX 11i v1 on more than one system, update your Ignite-UX server. • Locate source media and codewords. Task 1: Backing Up Your Configuration Files If you plan to cold-install HP-UX 11i v1 on a system that already has HP-UX installed, make sure to save the files that you want to reinstall, such as: • Configuration files in /etc • The contents of /usr/local • Any local home directories (that is, those you do not import from another system) • Any configuration files located in the /etc/opt directories for installed software If multiple users are preparing for the cold-install, you might consider creating a file system. Mount it with sam. Then create a subdirectory for each system or user (for example, /backup/your_sys). As root, copy the files. For example: 1. Copy all config files from /etc on a system named system1 to system system2. On system2, enter: mkdir /backup/system1/etc rcp -p your_name@system1:/etc/* /backup/system1/etc/ 2. Copy your local home directory to the backup system: mkdir /backup/system1/home rcp -pr your_name@system1:/home/ /backup/system1/home/ 64 Chapter 4 Preparing to Install or Update to HP-UX 11i v1 Cold-Install Tasks Colors and Fonts If you want to preserve your colors and fonts in CDE, execute the following command on the system you are updating: xrdb -q > xrdb.save Then save the xrdb.save file in your backup directory. Task 2: Backing Up Your System Back up your system before performing a cold-install, and again after the cold-install is complete. If a problem occurs, you can easily restore the system to its original state. See “Backing Up Your System” on page 69 for more information. Task 3: Updating Your Ignite-UX Server If you intend to cold-install HP-UX 11i v1 on more than one system, update your Ignite-UX server. The HP-UX 11i v1 DVD contains the complete Ignite-UX product. When you cold-install HP-UX 11i v1 from the media, a subset of Ignite-UX is used to perform the installation on a single system. If you plan to update an existing Ignite-UX server to install HP-UX 11i v1 on more than one system in your network, update your Ignite-UX server first. Chapter 4 65 Preparing to Install or Update to HP-UX 11i v1 Cold-Install Tasks Updating your Ignite-UX server and using it to update other systems ensures that: • You keep consistent kernel configuration with specific drivers, daemons, and kernel tunables on all systems. • You have the following commands to create an operating system recovery archive: make_net_recovery and make_tape_recovery. Refer to the make_net_recovery (1M) and make_tape_recovery (1M) manpages for information. You can also download the latest Ignite-UX software and documentation from the Ignite-UX Web site: http://software.hp.com/products/IUX Task 4: Locating Source Media and Codewords Locate the source media needed for the cold-install. See “Locating Source Media and Codewords” on page 72 for instructions. 66 Chapter 4 Preparing to Install or Update to HP-UX 11i v1 Update Tasks Update Tasks Prior to updating to HP-UX 11i v1, perform these tasks: • Identify all software products and bundles on your system. • Rebuild the HP-UX kernel. • Rename your log files to make it easier to find problems encountered during an update. • Back up your system using any supported HP-UX backup software. • Locate source media and codewords. Task 1: Identifying Software Versions Run the swlist command, and print the list of all software products and bundles prior to updating to HP-UX 11i v1. For example, enter: /usr/sbin/swlist | lp After updating to HP-UX 11i v1, run the swlist command again and print the list of all products and bundles. Compare the two lists to determine what software products and bundles still need to be updated. Task 2: Rebuilding the Kernel The update can fail if the HP-UX kernel build fails in the starting environment. To ensure that you have a reliable starting point, rebuild the kernel before you update: 1. As root, enter: /usr/sbin/mk_kernel 2. Fix any problems listed in the mk_kernel output. 3. Reboot your system to ensure that your new kernel boots. Chapter 4 67 Preparing to Install or Update to HP-UX 11i v1 Update Tasks Task 3: Renaming Your Log Files To make it easier to look for problems encountered during an update, rename the log files before starting an update: 1. cd /var/adm/sw 2. As root, rename each log file. For example: mv swagent.log swagent_old.log Task 4: Backing Up Your System Back up your system before performing an update, and again after the update is complete. If a problem occurs, you can easily restore the system to its original state. See “Backing Up Your System” on page 69 for more information. Task 5: Locating Source Media and Codewords Locate the source media needed for the update. See “Locating Source Media and Codewords” on page 72 for instructions. 68 Chapter 4 Preparing to Install or Update to HP-UX 11i v1 Backing Up Your System Backing Up Your System Back up your system before performing a cold-install or update, and again after the cold-install or update. If a problem occurs, you can easily restore the system to its original state. Backing up your system includes the following tasks: • Task 1: Backing Up Your Data Files • Task 2: Creating an Operating System Recovery Archive Task 1: Backing Up Your Data Files The most effective way to ensure against loss of your system's data is to copy the data from your system onto storage media (such as magnetic tape or optical disk) that you can store away from your system, so that you can recover the data if something happens to your primary copies. You can choose from a number of different backup methods depending on your system backup needs. The /usr/sbin/fbackup command is the recommended HP-UX backup utility. The fbackup command can do the following: • Indicate specific files or directories to include or exclude from a backup • Specify different levels of backup on a daily, a weekly, or monthly basis • Create an online index file Using the normal tape location to do a full backup, insert a new tape and enter: fbackup -f/dev/rmt/0m -i -v Later, to return the system to its previous state, use the frecover command. Refer to the frecover (1M) manpage for examples or the Managing Systems and Workgroups: A Guide for HP-UX System Administrators. The guide is available at the HP Technical Documentation Web site: http://docs.hp.com/hpux/os/11iv1 Chapter 4 69 Preparing to Install or Update to HP-UX 11i v1 Backing Up Your System Task 2: Creating an Operating System Recovery Archive To protect your data, create an operating system recovery archive to be used in the event of a system crash. The Ignite-UX server has two commands you can use to create an operating system recovery archive: • make_net_recovery Use this command to create an operating system recovery archive on another system on the network. • make_tape_recovery Use this command to create an operating system recovery archive on a bootable recovery tape for an LVM or whole disk file system while it is up and running. NOTE The Ignite-UX recovery commands only back up the Operating System files and not your data files. Using make_net_recovery The Ignite-UX server has the make_net_recovery command to create an operating system recovery archive on another system on the network. The archive created by make_net_recovery is specific to the system it was created for and its identity includes host name, IP address, networking information, and so on. In the event of root disk failure, you use the Ignite-UX server to restore the system by installing the operating system recovery archive. The contents of the operating system recovery archive always include all files and directories that are essential to bringing up a functional system. This essential list is predefined by make_net_recovery. You can run make_net_recovery in its interactive mode to review the directories and files that make up the essential list, and also to add or remove other data from the archive on a disk/volume group, file, or directory basis. 70 Chapter 4 Preparing to Install or Update to HP-UX 11i v1 Backing Up Your System For more information on using make_net_recovery, refer to the make_net_recovery (1M) manpage or the Ignite-UX Administration Guide. The guide is available on the HP-UX 11i v1 Instant Information CD and at the HP Technical Documentation Web site: http://docs.hp.com/hpux/os/11iv1 Using make_tape_recovery The Ignite-UX server’s make_tape_recovery command creates a bootable operating system recovery tape for an LVM or whole disk file system while it is up and running. When a system has a logical volume layout, the recovery tape only includes data from the root volume group, plus data from any non-root volume group containing the /usr directory. You can run make_tape_recovery either on the Ignite-UX server or locally on the system from which you are trying to make an operating system recovery tape. To create the bootable recovery tape, enter: /opt/ignite/bin/make_tape_recovery -Av where A specifies the entire root disk or volume group and v is for verbose mode. Also, you can specify more than one volume group with the -x option. If you intend to use a tape drive other than the default (/dev/rmt/0m), modify the command to point to the device you want to use, for example, a tape drive at /dev/rmt/3mn: /opt/ignite/bin/make_tape_recovery -Av -a /dev/rmt/3mn To recover a failed system disk or volume group after an operating system recovery tape has been made, simply load the recovery tape, boot the system and interrupt the boot sequence to redirect to the tape drive. Allow the install process to complete. Do not intervene. The system will reboot and, because map files for all associated volume groups have been saved on the tape, any other existing volume groups are imported and mounted automatically. Data that is not in the root volume group must be backed up and recovered using normal backup utilities. For more information on using make_tape_recovery, refer to the make_tape_recovery (1M) manpage on an Ignite-UX server or the Ignite-UX Administration Guide. The guide is available on the HP-UX 11i v1 Instant Information CD and at the HP Technical Documentation Web site: http://docs.hp.com/hpux/os/11iv1 Chapter 4 71 Preparing to Install or Update to HP-UX 11i v1 Locating Source Media and Codewords Locating Source Media and Codewords Now that you have backed up your system and important data files, you need to locate the source media needed for the cold-install or update: • If you are cold-installing or updating one system at a time — Cold-install or update directly from the DVDs in the HP-UX 11i v1 media kit: — HP-UX 11i v1 OE media (2 CDs or 1 DVD) — Boot and install a new system or update an existing HP-UX 10.20, HP-UX 11.0, or HP-UX 11i system. — Support Plus CD — Install current HP-UX 11i v1 patch bundles to fix defects in the OS and OE applications. — HP-UX Application media (multiple CDs or 1 DVD) — Install applications not installed with the OE or install a newer version of an OE application. Some applications installed with an HP-UX 11i v1 OE may be older versions than those available on the HP-UX Applications CDs or DVD supplied in the media kit. Products available on Application CDs or DVD are listed in the CD_TABLE_OF_CONTENTS file on each CD or DVD. • If you plan to cold-install on many systems in your enterprise — Use an Ignite-UX server to create a golden image from which to cold-install. A golden image is a snapshot of a known, good operating system installation and configuration for use in installing other clients. The copied (source) client is called the golden image. This install image can contain the OS and OE, other applications, and any needed patches. After the archive is in place, either on the Ignite-UX server or on another system, cold-install on each client system in a single-pass operation; you need to reboot each client only once. For details on installing an Ignite-UX server, refer to the Ignite-UX Administration Guide supplied on the HP-UX Instant Information CD and at the HP Technical Documentation Web site: http://docs.hp.com/hpux/os/11iv1 72 Chapter 4 Preparing to Install or Update to HP-UX 11i v1 Locating Source Media and Codewords You can obtain a codeword for a purchased product by contacting one of the HP licensing services in Table 4-1: Table 4-1 Location Asia HP Licensing Services Telephone 0120.42.1231 (Inside Japan) Email [email protected] 0426.48.9310 (Inside Japan) +81.426.48.9312 (Outside Japan) NOTE Europe +33 (0)4.76.14.15.29 [email protected] North America (800) 538-1733 [email protected] For more information on HP licensing services and codeword redemption, go to Software License Manager Web site: http://licensing.hp.com The Codeword Request forms also list the telephone numbers and Web site for codeword redemption. Chapter 4 73 Preparing to Install or Update to HP-UX 11i v1 The Next Step The Next Step You are now ready to cold-install or update to HP-UX 11i v1. 74 • To cold-install: see Chapter 5, “Cold-Installing HP-UX 11i v1,” on page 75. • To update: see Chapter 6, “Updating to HP-UX 11i v1,” on page 91. Chapter 4 5 Cold-Installing HP-UX 11i v1 This chapter describes cold-installing HP-UX 11i v1. What You Will Find in This Chapter • “Before You Begin” on page 76 • “Reviewing the Cold-Install Process” on page 77 • “Cold-Installing HP-UX 11i v1” on page 79 • “Retrieving Information After Cold-Installing” on page 87 • “The Next Step” on page 89 Time Estimate for This Chapter: Approximately 2-3 hours, depending on your system and whether you are installing the HP-UX operating system (OS) or an HP-UX Operating Environment (OE). NOTE For customers ordering new systems with the Instant Ignition option (also known as factory ignited), the cold-installation process described here has already been performed. Skip this chapter and proceed to Chapter 8, “Verifying System Install or Update,” on page 119. CAUTION The cold-install process overwrites everything on the root (/) disk. Make sure you completed backups in “Backing Up Your System” on page 69. Chapter 5 75 Cold-Installing HP-UX 11i v1 Before You Begin Before You Begin Before you cold-install HP-UX 11i v1, make sure that: 76 • Your system meets the system requirements to install and operate HP-UX 11i v1. For more details see Chapter 2, “System Requirements for Cold-Installing and Updating,” on page 31. • You are installing from a supported migration path. See “Supported Cold-Install Paths to HP-UX 11i v1” on page 50. • You understand all of the considerations provided in Chapter 3, particularly “Additional Cold-Install Considerations” on page 56. • You have completed the preparation tasks required to cold-install your system. For more information see Chapter 4, “Preparing to Install or Update to HP-UX 11i v1,” on page 63. Chapter 5 Cold-Installing HP-UX 11i v1 Reviewing the Cold-Install Process Reviewing the Cold-Install Process Figure 5-1 on page 78 shows the overall process, along with alternative methods of cold-installing HP-UX 11i v1. Alternative methods of cold-installing include the following: NOTE Chapter 5 • Installing from network depots — Use Software Distributor commands to create depots containing OS, OE, and other software bundles, then install from the depot using Ignite-UX. For help with this method, refer to the swinstall (1M) manpage, the Software Distributor Administration Guide, and the Ignite-UX Administration Guide. • Installing from golden images — If you need to install the same OS/OE and applications on many systems in your network, use an Ignite-UX server as explained in the Ignite-UX Administration Guide. With Ignite-UX, you can create a single install image (golden image) containing OS/OE bundles, application bundles, and patch bundles, then install the image on multiple systems in your environment. If your system is on HP Mission Critical Support, discuss the proper method of installing and patching the OE with your HP Customer Engineer. 77 Cold-Installing HP-UX 11i v1 Reviewing the Cold-Install Process Figure 5-1 Cold-Installing HP-UX 11i v1 Determine install approach From Media Install 11i OS/OE using Ignite-UX Install non-OE applications using swinstall If Factory Integrated From Depots 1 Create 2 install depots: • OE depot: OS/OE, QPK 4 • AR depot: Applications, QPK 4 (See Chapter 7.) Install from OE depot using Ignite-UX with config files for both depots Install QPK patches from the Support Plus CD using swinstall (See Chapter 7.) Using tools from ITRC, identify and install additional needed patches 3 From Golden Image 2 Create Install Golden Image using Ignite-UX Server 2 Install image using Ignite-UX Server Install non-OE applications from AR depot using swinstall (See Chapter 7.) 1 For help creating depots, refer to the Software Distributor Administration Guide. 2 Install 3rd-party and internal software Create archive/recovery image Golden image can contain OS/OE, patches, and application bundles. For help creating golden images, refer to the Ignite-UX Administration Guide. 3 The Custom Patch Manager (CPM) can be found at the ITRC (http://itrc.hp.com) and can be used to find additional needed patches, such as patches for non-OE applications and new security patches. 4 Quality Pack on the Support Plus CD contains patch bundles for the OS, OEs, and applications; Select the GOLDQPK11i depot, which contains both the GOLDBASE11i and GOLDAPPS11i bundles, for both the OE depot and AR depot. Done 78 Chapter 5 Cold-Installing HP-UX 11i v1 Cold-Installing HP-UX 11i v1 Cold-Installing HP-UX 11i v1 This section describes cold-installing from the HP-UX 11i v1 CDs or DVDs, including the operating system, a selected Operating Environment (OE) bundle, network drivers, CDE language bundle, diagnostics, and required patches from the Support Plus CD. Before you begin, review Appendix B, “Known Problems and Troubleshooting,” on page 135 for any installation issues that apply to your system. This section contains the following tasks: • “Task 1: Booting Your Machine” on page 80 • “Task 2: Selecting Your Installation Type” on page 81 • “Task 3: Configuring Your Installation” on page 82 • “Task 4: Deselecting OE Software Bundles” on page 84 • “Task 5: Finishing Your Installation” on page 85 Required Media Have these media ready from the HP-UX 11i v1 media kit: CAUTION Chapter 5 • HP-UX 11i v1 OE CDs or DVD • Support Plus CD Cold-installing overwrites everything on the target disk. 79 Cold-Installing HP-UX 11i v1 Cold-Installing HP-UX 11i v1 Task 1: Booting Your Machine This task describes how to boot your system from the install media. Step 1. Make sure any external devices connected to the target system are turned on and operational. Step 2. Insert the HP-UX 11i v1 CD or DVD into the drive. Step 3. Stop the autoboot by pressing Esc on workstations or any key on servers. The boot console menu is displayed. If you need help, enter HELP Step 4. Ensure that Fast Boot is enabled. a. Select the Configuration Menu CO b. If the Fast Boot selection is available, switch Fast Boot ON: FB ON c. Return to the Main Menu MA (Switch Fast Boot back OFF after installing HP-UX 11i.) The full memory check that is run when Fast Boot is OFF may take several hours on a large system. Step 5. Search for bootable devices, using the choices displayed (for example, enter search or sea). A table similar to this is displayed: Path# ----P0 P1 P2 Device Path ----------SCSI LAN.1.2.3.4.5.6 FWSCSI.6.0 Device Type ----------HP DVD-ROM 1.2.3.4 IBM DDRS-34560WS Of the media listed, a SCSI device (FWSCSI) is usually a disk, whereas a single-ended SCSI device (SCSI) can be a disk, CD or DVD drive. Step 6. Boot from the CD or DVD drive using the listed path number. For the drive shown in the previous example (P0), enter BOOT P0 Step 7. After a few minutes, at the Interact with IPL? prompt press n. The install kernel loads (3-5 minutes), after which a screen might prompt you to enter the keyboard language of your console. Step 8. Enter the number and press Enter again to confirm. 80 Chapter 5 Cold-Installing HP-UX 11i v1 Cold-Installing HP-UX 11i v1 Task 2: Selecting Your Installation Type The system displays the Ignite-UX Welcome screen for the HP-UX installation process. When the initial Ignite-UX Welcome screen appears, read how to navigate and select choices on this terminal interface: • Use the Tab key to navigate between fields and the arrow keys to navigate within fields. • Use the Return/Enter key to select an item. Pressing Return/Enter or the spacebar opens a menu list. • For Help, use Ctrl-K for navigation key help and Ctrl-F (or F1) for context-sensitive help. • You can enter the underlined letter of an item (such as I for install HP-UX) to navigate more quickly. The remainder of this section describes how to choose the degree of customization needed to configure your installation. Step 1. From the Ignite-UX Welcome screen, select Install HP-UX to begin interacting with the Ignite-UX (cold-install) program and then press Enter. The system displays the User Interface and Media Options window. Step 2. From the User Interface and Media Options window, choose the degree of customizing needed to configure the installation. Mark your choices and select OK. • Select the default setting (Media only installation) shown in Source Location Options for installing from a CD or DVD. • Select from one of the three choices shown in User Interface Options: — Guided Installation provides tutorial information and limited choices for inexperienced Ignite-UX users. (Ignite-UX enables you to exit from Guided Installation. You can restart the configuration using Advanced Installation later either by selecting the Cancel button or pressing C.) Chapter 5 81 Cold-Installing HP-UX 11i v1 Cold-Installing HP-UX 11i v1 — Advanced Installation enables you to customize your system on tabbed screens. Use this mode to change VxVM settings. You may also find it convenient to set system parameters, network services, file-system characteristics, and other configuration details. For more help on using Advanced Installation, refer to the Ignite-UX Administration Guide. — No User Interface uses all the defaults and begins the session. The remaining sections take you through the Guided Installation option. Step 3. If your system has a tape drive attached, the Media Installation Selection screen appears: Media Installation Selection This screen provides an option to switch the install source from the default CD/DVD to a recovery tape. This is helpful for those systems and for tape devices which do not support booting from a tape. [ * ] [ ] [ OK CD/DVD Installation Boot from CD/DVD, Recover from Tape ] [ Cancel ] [ Help ] Step 4. Tab to [ OK ] and press Enter. Task 3: Configuring Your Installation At this point, the system displays the Install HP-UX Wizard screen for the HP-UX installation process. You are now at the first step of the Install HP-UX Wizard. This section describes how to configure your installation using the Guided Installation process. Step 1. From the Install HP-UX Wizard screen, select an overall system configuration. Press Enter to accept the default option, HP-UX B.11.11 Default. The system displays the Operating Environment screen. Step 2. From the Operating Environment screen, select the type of Operating Environment you want to install on your system. Press Enter to view the choices. Step 3. On the Root Disk screen select the disk to store your root file system. Press Enter to view the choices. If you are unsure of what to choose, keep the default selection that has been calculated by the install program. 82 Chapter 5 Cold-Installing HP-UX 11i v1 Cold-Installing HP-UX 11i v1 Step 4. On the Root Swap Space screen, specify the amount of root swap space you need. Press Enter to view the choices. Some initial calculations have been performed by the install program, and a recommended value has been set for you. You can either accept this value or change it before continuing. Step 5. On the File System Type screen, select the type of file system you want to use. Unless you have other requirements, use the default value chosen by the install program. NOTE If you select VxVM, the root disk cannot be moved to another SCSI bus or address that results in a change in the hardware path to the device. If it is moved, you may not be able to boot safely from it. This is similar to the limitation present in LVM. Step 6. On the Root Group screen, specify how many disks you want placed into the root disk volume group. If you have more than one disk, select Yes to choose the Striping option. Step 7. On the Languages screen, browse the available languages, marking the desired selections. During the first boot, you may have been asked this already. Step 8. On the Additional Software screen, select any additional software that you want loaded onto your system. Browse the list, marking your selections, then continue to the next step. Step 9. On the Pre-Install Disk Information screen, identify which disks to overwrite during the install process. If you see a disk in the list that you do not want included, back up to the root disk selection and choose another disk. Otherwise, continue on to the next step. Step 10. On the Pre-Install Check Information screen (Step 2), review any errors, warnings, or notes. Warnings are simply informational. If there are any errors, you need to resolve them before the installation can continue. Step 11. On the System Summary screen, use the Show Summary button to view a summary of how your system will be configured. If you see any problems, or want to change any of your selections, back up to the appropriate step, and make the needed changes. Otherwise, select Finish (at the bottom of the tabs). You can Cancel at this time. If you cancel, you can start again. Chapter 5 83 Cold-Installing HP-UX 11i v1 Cold-Installing HP-UX 11i v1 Step 12. At the end of the Guided Installation session, a screen is displayed that enables you to review any messages that Ignite-UX encountered. If there are any errors, resolve them before continuing with the installation. NOTE Ignore any message stating that /var needs to be larger than available to hold a dump file. /var typically only needs to be set to 50-100 percent as large as the current memory to handle dump files. Task 4: Deselecting OE Software Bundles If you use the Guided Installation or Advanced Installations, then you can deselect the software bundles that are installed by default. For a list of default-installed software bundles, see “Default-Installed Software” on page 184. If you choose the No User Interface option, then you cannot deselect the default-installed software bundles. To deselect the software bundles: Step 1. In the Guided Installation or Advanced Installation windows, select the Software tab. Step 2. Use the arrow keys to select a bundle and the spacebar to change the option. IMPORTANT 84 Do not deselect the HPUXBaseAux, HWEnable11i, OnlineDiag, FEATURE11-11, or BUNDLE11i bundles. If in doubt, leave the selections as default. Other software products may be selectable. However, HP recommends that you do not deselect any products at this time. For example, you may deselect a software bundle that is necessary for another program to work correctly. Chapter 5 Cold-Installing HP-UX 11i v1 Cold-Installing HP-UX 11i v1 Task 5: Finishing Your Installation Finishing the Guided Installation process begins with filesets being copied from the media to the hard disk. The system automatically reboots during the installation process. Installing HP-UX 11i v1 installs a minimum set of default networking drivers that apply to the system. Refer to the HP-UX 11i v1 Release Notes available at: http://docs.hp.com/hpux/os/11iv1/index.html You may need to select or specify other available networking drivers to enable other cards on your system. Step 1. Select Finish to complete the Guided Installation. The system configures the hard disks and loads a minimum set of commands and libraries. SD then downloads all the products and patches from CD1 or DVD1. Step 2. When prompted, replace the HP-UX 11i v1 CD or DVD with the requested CD or DVD from the media kit. Software is automatically loaded from each CD or DVD. If you see the following message you may have pressed Enter before changing the CD or DVD: Unable to verify CD-ROM media content ... If so, verify that you have changed the CD or DVD and then select the displayed Recovery Action 1: Retry software Load... and press Enter again. The system automatically reboots after all software has been loaded. Step 3. Eject the last CD or DVD. Step 4. Depending on how you set up your parameters, the system either sets basic network configurations automatically, or calls the set_parms command after it has rebooted to enable you to set the root password, date and time, time zone, IP address, and additional network parameters. After set_parms is executed, then the Welcome to HP-UX screen is displayed. Step 5. To use a keyboard on this interface, you must specify a language mapping to be used by X Windows and the Internal Terminal Emulator (ITE). Choose the appropriate language. For English, select number 26. Chapter 5 85 Cold-Installing HP-UX 11i v1 Cold-Installing HP-UX 11i v1 Step 6. You are prompted to answer a few questions before you can use the system. The first is whether or not you plan to use the system on a network. Enter the basic network information for your system. Step 7. Confirm your choices. You are now finished with the install procedures and presented with a login screen. Step 8. Log in to the system as root. Step 9. After the cold-install, store the HP-UX CDs or DVDs in a safe place. You may need them to install drivers or other software later. Step 10. After installing or updating applications, insert the HP-UX Support Plus CD and install the Quality Pack patch bundles to fix defects in the operating system and OE applications to ensure your system is functioning at the highest quality. For example: /usr/sbin/swinstall -s /cdrom/GOLDQPK11i \ -x patch_match_target=true -x autoreboot=true The depot named GOLDQPK11i includes two quality pack bundles, GOLDBASE11i, which provides defect fixes for the Base OE (including the always-installed and selectable driver products), and GOLDAPPS11i, which provides defect fixes for the OE applications. For more about this package, refer to the Quality Pack page available at the following Web site: http://us-support.external.hp.com/estaff/bin/doc.pl/screen=e staffDocs/distrib_redir=0+1099518879|*?File=patches_main%2Fh pux_bundles_overview.htm 86 Chapter 5 Cold-Installing HP-UX 11i v1 Retrieving Information After Cold-Installing Retrieving Information After Cold-Installing After completing the cold-install, you can retrieve the information you had previously saved onto another system. Create a New Root Home Directory Consider creating a root home directory that is not /. Doing this keeps the user root dot files out of the / directory. Make sure it is on the root volume by calling it something like /homeroot. Doing this is especially important if you are using Logical Volume Manager (LVM) and /home is a separate volume. 1. From the CDE login screen, select Options -> Command Line Login and log in as root. 2. Except on trusted systems, edit /etc/passwd to change the home directory from root to /homeroot and save it. 3. Create the /homeroot directory: mkdir /homeroot 4. Move root’s personal files (files beginning with . ) to /homeroot: mv /.[a-zA-Z]* /homeroot 5. Exit and log in again as root. Recover Files Recover all the customized and personal files that you saved previously by merging them manually. For example, do not overwrite /etc/passwd with your old version. Instead, either paste in entries from your old files or merge the old information into the new files. Chapter 5 87 Cold-Installing HP-UX 11i v1 Retrieving Information After Cold-Installing Restore /home If you had a local home directory, you can restore it as follows: • For instance, if you copied it to /backup/system1/home, enter these commands: cd /backup/system1/home find -depth | cpio -pdm /system1/home • If you backed it up to tape with fbackup, enter: frecover -x -i /system1/home -v Restore Other Files Carefully use the same techniques to restore other files and directories, such as /usr, /local, and /opt. For help in importing entire volume groups, refer to either Managing Systems and Workgroups: A Guide for HP-UX System Administrators or Managing Superdome Complexes. The commands cited in this section do not write over newer files, so your new operating system and any files you update are well protected. 88 Chapter 5 Cold-Installing HP-UX 11i v1 The Next Step The Next Step Continue with Chapter 7, “Installing HP Applications and Patches,” on page 113. Chapter 5 89 Cold-Installing HP-UX 11i v1 The Next Step 90 Chapter 5 6 Updating to HP-UX 11i v1 This chapter describes updating your system to HP-UX 11i v1 using the update-ux command. What You Will Find in This Chapter • “Before You Begin” on page 92 • “Reviewing the Update Process” on page 94 • “Updating Tips” on page 96 • “Updating to HP-UX 11i v1” on page 98 • “Post-Update Task: Configuring OE Applications” on page 111 • “The Next Step” on page 112 Time Estimate for This Chapter: Approximately 3-4 hours, depending on your system and whether you are installing the HP-UX operating system (OS) or an HP-UX Operating Environment (OE). Chapter 6 91 Updating to HP-UX 11i v1 Before You Begin Before You Begin Before you update to HP-UX 11i v1, make sure that: • You are updating from a supported migration path. See “Supported Update Paths to HP-UX 11i v1” on page 51. • You understand all of the considerations provided in Chapter 3, particularly “Additional Update Considerations” on page 57. • Your system meets the system requirements to update and operate HP-UX 11i v1. For more details see Chapter 2, “System Requirements for Cold-Installing and Updating,” on page 31. • You have completed the preparation tasks required to update your system. For more information see Chapter 4, “Preparing to Install or Update to HP-UX 11i v1,” on page 63. CAUTION If the Distributed File System (DFS) is installed and in use on your HP-UX 10.20 system to manage large numbers of files, update-ux removes it and associated data during the update to HP-UX 11i v1. If you need to continue using DFS, do not update to HP-UX 11.x or HP-UX 11i v1. NOTE If your system already is running any version of the HP Apache-based Web Server, installing or updating to an HP-UX 11i v1 Operating Environment installs the version of HP-UX Web Server Suite included with the HP-UX 11i v1 OE. Refer to the HP-UX 11i v1 Release Notes for more information. 92 Chapter 6 Updating to HP-UX 11i v1 Before You Begin Updating Netscape Directory Server Although the Netscape Directory Server (NDS) Version 6.02 is included in HP-UX 11i v1 OEs, you must explicitly select NDS during the install or update process. If you do not select NDS, it will not be installed with HP-UX 11i v1. NOTE Currently, Netscape Directory Server Version 6.02 is not included with the HP-UX 11i v1 Operating Environments. If you want to have the iPlanet 5.0 product, order the AR1202 CD or DVD for this product separately. CAUTION If you have NDS version B.02.00.05 and are updating to HP-UX 11i v1, be sure either to select the new version of NDS during the update or to remove the old version from your system. If you run NDS version B.02.00.05 with HP-UX 11i v1, the server will cease to work and all client systems may lose the ability to have anyone log in. After NDS is installed or updated with HP-UX 11i v1, additional configuration steps are required to initiate NDS. Refer to the NDS release notes available on the HP-UX 11i v1 Instant Information CD for instructions. Chapter 6 93 Updating to HP-UX 11i v1 Reviewing the Update Process Reviewing the Update Process This section describes updating to HP-UX 11i v1 using the update-ux command and Software Distributor (SD) tools to selectively overwrite the operating system and application software from a media or network source depot. Figure 6-1 on page 95 shows the overall update process. You can update your system using one of the following methods: • From a network depot — Use Software Distributor commands to create depots containing OS, OE, and other software bundles, then install from the depot using Ignite-UX. For help with this method, refer to the swinstall (1M) manpage, the Software Distributor Administration Guide, and the Ignite-UX Administration Guide. See “Updating from a Network Depot” on page 107 for an example. • From DVD media — Use the update-ux command described in “Updating to HP-UX 11i v1” on page 98. NOTE If your system is on HP Mission Critical Support, discuss the proper method of installing and patching the OE with your HP Customer Engineer. IMPORTANT You must install the latest version of Update-UX prior to updating your system. Failure to do so may cause the update to fail. 94 Chapter 6 Updating to HP-UX 11i v1 Reviewing the Update Process Figure 6-1 Updating to HP-UX 11i v1 Create archive/recovery image Determine update approach update Important! Install update-ux (See page 100.) depots Determine source from media cold-install Cold-Install from media, depots or golden image (See Chapter 5.) Continue to update OS/OE from 11i OE media using update-ux (Start at page 102.) Update non-OE applications from Application media using swinstall Create one or more depots Update to 11i OE from depot containing OS/OE and Support Plus bundles using update-ux (See page 107.) Update non-OE applications using swinstall (See Chapter 7.) (See Chapter 7.) Identify and install non-OE Install patches from Support Plus media using swinstall (See Chapter 7.) Identifypatches and install non-OE patches using Custom Patch Install 3rd-party and internal software Create archive/recovery image DONE Chapter 6 95 Updating to HP-UX 11i v1 Updating Tips Updating Tips Table 6-1 suggests some tips and recommendations to be aware of during an update process: Table 6-1 Updating Tips Topic Monitoring the Update Process Tip If you want to view the update process in detail, open another terminal window and drag it aside so you can also watch for any messages on the window running update-ux. Then, use the tail command to view swinstall messages being logged: tail -f /var/adm/sw/swagent.log If you want to log all messages directed to the console, use the script command. For example, to log all messages into a file named /tmp/updateOS, enter: script -a /tmp/updateOS To halt the script log process, enter: exit Running Other Commands You can run other commands during an update, such as viewing files and tail. However, do not run other Software Distributor commands during an update; doing so may cause the commands to function improperly. All Software Does Not Get Updated The update-ux command updates the HP-UX OS and any software specified in additional software bundles available on the source media or depot. When an OE is specified, some products in the OE are not updated automatically when a version of the product not previously installed with an OE already exists on the system. You have to update or reinstall those products after updating HP-UX 11i v1. For more information about how to update these additional software bundles, see “Updating Selectable Software” on page 110. 96 Chapter 6 Updating to HP-UX 11i v1 Updating Tips Table 6-1 Topic In Case of Trouble Updating Tips (Continued) Tip The update-ux command returns an error value when it is not successful: 1 - Error during execution; update aborted. 2 - Update aborted via user action (-n or keyboard press) Messages are recorded in /var/adm/sw/swagent.log, /var/adm/sw/swinstall.log, and /var/adm/sw/update-ux.log. When updating Ignite-UX, also look at its log in /var/adm/sw/. If you encounter a problem during the update process, review Appendix B, “Known Problems and Troubleshooting,” on page 135 for possible solutions. Chapter 6 97 Updating to HP-UX 11i v1 Updating to HP-UX 11i v1 Updating to HP-UX 11i v1 Updating your system using update-ux includes the following tasks: 1. Create a network depot so you can update other systems on the network. See “Task 1: Creating a Network Depot (Optional)” on page 99. If you are not creating a network depot, you can skip this task. 2. Install the latest version of the update-ux command on your system. See “Task 2: Installing the Latest Update-UX Bundle (Required)” on page 100. 3. Use update-ux to update your system. See “Task 3: Using update-ux (Required)” on page 102. Several examples are provided to assist you with some of the most common scenarios for using update-ux. After updating to HP-UX 11i v1, you might need to configure OE Applications to make your system fully functional. NOTE update-ux removes all HP-UX 10.x patches from the system prior to updating to HP-UX 11i v1. Any 10.x applications left on the system after the update may not be supportable if they required those patches. After migrating your system, consult the documentation for those remaining applications for HP-UX 11i v1 requirements. CAUTION If you are using CDs to update an HP-UX 10.20 system to the HP-UX 11i v1 December 2004 (B.11.11) Operating Environments, the update-ux command will fail because HP-UX 10.20 does not support Rockridge extension. To resolve this issue, first update to the desired HP-UX 11i v1 December 2003 Operating Environments and then update to the desired HP-UX 11i v1 December 2004 Operating Environments. 98 Chapter 6 Updating to HP-UX 11i v1 Updating to HP-UX 11i v1 Task 1: Creating a Network Depot (Optional) If you want to update other systems on the network then you must first create a network depot before you update your system and other systems. NOTE This optional step pertains to creating a network depot so you can update other systems on the network. If you already have a network depot, go to “Task 2: Installing the Latest Update-UX Bundle (Required)” on page 100. As root, follow this procedure to create a network depot from the HP-UX 11i v1 CD or DVD onto a depot server or other system running HP-UX 11i v1 in your network: Step 1. Verify that you have at least 2 GB of free space to create the network depot on another system in your network. If this space is not available, use sam either to create a new volume group or to extend an existing volume group. For help, refer either to SAM help or Managing Systems and Workgroups: A Guide for HP-UX System Administrators. Step 2. Log in as root and mount the logical volume on a new directory named /update. This directory will hold your network depot. Step 3. Insert the HP-UX 11i v1 CD or DVD into the drive. Step 4. Find the CD or DVD device file name: ioscan -f -C disk | more /dev/dsk/c1t2d0 is a typical CD device name. Step 5. Create the directory under root(/): • • CD: mkdir /cdrom DVD: mkdir /dvdrom Step 6. Mount the CD or DVD onto the new directory as a file system. For example: • • Chapter 6 CD: mount /dev/dsk/c1t2d0 /cdrom DVD: mount /dev/dsk/c1t2d0 /dvdrom 99 Updating to HP-UX 11i v1 Updating to HP-UX 11i v1 Step 7. Merge all products on the mounted CD or DVD to the target depot, for example /update/update-depot: • • CD: swcopy -s /cdrom \* @ /update/update-depot DVD: swcopy -s /dvdrom \* @ /update/update-depot Step 8. Unmount the CD or DVD from its directory: • • CD: umount /cdrom DVD: umount /dvdrom If you are updating to HP-UX 11i v1 using CD, follow steps 9 - 10; if you are using DVD, continue to “Task 2: Installing the Latest Update-UX Bundle (Required)” on page 100. Step 9. Insert the requested HP-UX 11i v1 CD. Step 10. Repeat Steps 6 through 8 for the requested OE CDs and the Support Plus CD. The network depot is now ready to update your system to HP-UX 11i v1. Continue with “Task 2: Installing the Latest Update-UX Bundle (Required)” on page 100. Task 2: Installing the Latest Update-UX Bundle (Required) This procedure describes how to install the latest version of the UPDATE-UX bundle, which includes the update-ux command. Step 1. Find the CD or DVD device file name: ioscan -f -C disk | more /dev/dsk/c1t2d0 is a typical CD device name. Step 2. Create the directory under root(/): • • CD: mkdir /cdrom DVD: mkdir /dvdrom Step 3. Mount the CD or DVD onto the new directory as a file system. For example: • • 100 CD: mount /dev/dsk/c1t2d0 /cdrom DVD: mount /dev/dsk/c1t2d0 /dvdrom Chapter 6 Updating to HP-UX 11i v1 Updating to HP-UX 11i v1 Step 4. Using ksh, Posix-sh, or Bourne shell, install update-ux on the target system; the depot example uses depot_server:/var/depots/my_depot • CD: swinstall -r -s /cdrom Update-UX \ \@ /var/adm/sw/update-ux.root 2> • DVD: swinstall -r -s /dvdrom Update-UX \ \@ /var/adm/sw/update-ux.root 2> swinstall -r -s depot_server:/var/depots/my_depot \ Update-UX \@ /var/adm/sw/update-ux.root 2> TIP The backslash (\) at the end of the first line is not needed if you enter the complete command on one line. The -r option writes log files to the specified alternate root (pseudo-root) location, update-ux.root. (Do not specify any other alternate root location.) Because the HP-UX 11i v1 Software Distributor tool contains many keywords that 10.20 and 11.00 SD do not recognize, installing update-ux initially at this alternate root location eliminates many unnecessary update-ux warnings. Immediately after update-ux is installed, a script copies update-ux to /usr/sbin/. When update-ux runs for the first time, it removes the initial version at the alternate root location. Chapter 6 101 Updating to HP-UX 11i v1 Updating to HP-UX 11i v1 Task 3: Using update-ux (Required) After you have installed the Update-UX bundle on the target system and, optionally, created an update depot containing all software to be installed, you can now proceed to update your target system. The Update-UX product includes a default selections file, update-ux.selections, which is installed in /usr/lib/sw. This file provides a list of bundles that are selected for install during an OS update. Update-UX provides support for the -f selection_file option on the update-ux command line. With this option you can create your own selections file and specify that your file be used in place of the default selections file. This provides you with the flexibility to deselect any bundles listed in the update-ux.selections file by providing your own file, which does not contain these bundles. To do this, you must first install the March 2004 version or later version of the Update-UX product onto your target system, then copy and edit the /usr/lib/sw/update-ux.selections file as desired. When executing Update-UX, your custom selections file can be specified on the update-ux command line via the -f selection_file option. Use the following syntax to run the update-ux command: update-ux -s source_location [-?] [-n|-y] [-i] [-f selection_file] [-x option=value] [sw_spec] where: -s source_location Specifies the source containing the new software depot. Possible locations are a local directory, a mounted DVD containing a depot, or a remote system-and-depot combination. All paths used in the source_location must be absolute paths. If source_location is a remote system and depot combination, specify the remote system first, followed by the absolute path to the remote depot, separated by a colon with no spaces; for example: swperf:/var/spool/sw -? 102 Prints the usage statement. Chapter 6 Updating to HP-UX 11i v1 Updating to HP-UX 11i v1 -n|-y Specifies whether or not update-ux issues a message and waits for your response to continue whenever something unexpected is attempted. Specify -n first (or omit this option) to have update-ux “not continue” when an error is issued. When you have reviewed or resolved all errors, use -y instead of -n to have update-ux ignore all messages that require a user response. -f selection_file Reads the list of software selections from selection_file instead of (or in addition to) the command line. This option enables you to select and update optional software or to deselect default-installed software. -i Specifies the swinstall interactive user interface to select software products from a depot or bundle during the update. For more information, refer to the swinstall (1M) manpage. -x option=value Specifies swinstall options to be applied during the update. For a typical update, no swinstall options are required. swinstall -p (preview) is not supported. For information on swinstall options, refer to the swinstall (1M) manpage or the Software Distributor Administration Guide. sw_spec Specifies one or more optional software bundles to be updated, such as an Operating Environment (OE) bundle name, a network-driver bundle, or Ignite-UX. If an OE bundle name is not included on the command line, only the core OS is updated. For more information, see Appendix C, “HP-UX 11i v1 Software Bundles,” on page 177. For more about update-ux, refer to the update-ux (1M) manpage. Chapter 6 103 Updating to HP-UX 11i v1 Updating to HP-UX 11i v1 Examples: Using update-ux to Update Your System Your system configuration and your planning determine how you use update-ux. This section provides some scenarios and examples of how you might use update-ux to update your system: 104 • “Updating to HP-UX 11i v1 OS (OE Installed)” on page 105 explains how to update to HP-UX 11i v1 with an Operating Environment. • “Updating to HP-UX 11i v1 OS (No OE Installed)” on page 106 describes how to update the HP-UX 11i v1 OS without an Operating Environment. • “Adding or Upgrading an OE” on page 106 explains how to update your system by either adding or upgrading the Operating Environment on your system. • “Downgrading an OE” on page 107 explains how to move your system from an advanced Operating Environment to a smaller Operating Environment. • “Updating from a Network Depot” on page 107 explains how to update your system from a server on the network. • “Updating Using Interactive Software Selection” on page 108 explains how to use the interactive option to manually select the software you want to update. • “Updating to a 64-bit OS” on page 108 shows you how to move a 32-bit system to a 64-bit OS. • “Update Using match_target” on page 109 explains how to update your system using the match_target option. • “Updating Selectable Software” on page 110 explains how to update your system with selectable software bundles. Chapter 6 Updating to HP-UX 11i v1 Updating to HP-UX 11i v1 Recommended Update Updating to HP-UX 11i v1 OS (OE Installed) To update to HP-UX 11i v1 and include an HP-UX 11i v1 Operating Environment, you need to specify the OE bundle name in the update-ux command. The OE bundle names are: HPUX11i-OE HP-UX 11i v1 Foundation OE HPUX11i-OE-Ent HP-UX 11i v1 Enterprise OE HPUX11i-OE-MC HP-UX 11i v1 Mission Critical OE HPUX11i-MTOE HP-UX 11i v1 Minimal Technical OE HPUX11i-TCOE HP-UX 11i v1 Technical Computing OE For example, to update to HP-UX 11i v1 and install the HP-UX 11i v1 Foundation OE, insert the HP-UX 11i v1 DVD in the local drive mounted at /dvdrom. As root, enter: /usr/sbin/update-ux -s /dvdrom HPUX11i-OE Alternately, if you want to update to HP-UX 11i v1 and install the Enterprise OE (from a supported update path), enter: /usr/sbin/update-ux -s /dvdrom HPUX11i-OE-Ent NOTE Make sure to read “Supported Update Paths to HP-UX 11i v1” on page 51 to ensure that you are updating your system from a supported update path. NOTE Make sure that you install all of the selectable OE bundles that you want at the same time that you do your update. See “Updating Selectable Software” on page 110 for more information. For details on what is included in each of the Operating Environments, see Appendix C, “HP-UX 11i v1 Software Bundles,” on page 177. Chapter 6 105 Updating to HP-UX 11i v1 Updating to HP-UX 11i v1 Updating to HP-UX 11i v1 OS (No OE Installed) IMPORTANT If you already have an Operating Environment installed on your system, you cannot use this scenario. Instead, use “Updating to HP-UX 11i v1 OS (OE Installed)” on page 105. Attempting this scenario when you already have an Operating Environment installed will cause update-ux to fail. NOTE HP strongly recommends that you update your system with an Operating Environment to provide you with an integrated and tested set of supporting software and applications. If you do not specify an OE bundle, update-ux only installs the OS, networking, diagnostic, and CDE bundles listed in Appendix C, “HP-UX 11i v1 Software Bundles,” on page 177. Any additional software bundles associated with an OE are not installed. For example, to update the HP-UX 11i v1 OS, insert the HP-UX 11i v1 DVD in the local mounted drive and enter the following command: /usr/sbin/update-ux -s /dvdrom Adding or Upgrading an OE To install an OE on an HP-UX 11i v1 system not containing an OE, or to upgrade HP-UX 11i v1 to higher-level OE (for example, HP-UX 11i v1 Foundation OE to HP-UX 11i v1 Enterprise OE), insert the HP-UX 11i v1 DVD and specify the new OE using the update-ux command. For example, to add the HP-UX 11i v1 Enterprise OE, enter: /usr/sbin/update-ux -s /dvdrom HPUX11i-OE-Ent When the update is complete, the original OE bundle wrapper (if one existed) is removed and replaced with the new bundle wrapper. 106 Chapter 6 Updating to HP-UX 11i v1 Updating to HP-UX 11i v1 IMPORTANT Upgrading to a higher level OE is supported only if you are updating from a lower level HP-UX 11i v1 Operating Environment. You cannot update, for example, from an HP-UX 11i v1.6 Foundation OE to HP-UX 11i v1 Enterprise OE. You cannot downgrade from a higher level OE to a lower level OE. Downgrading an OE If you want to downgrade your system from a higher-level OE, say, from Mission Critical OE to Foundation OE, first use update-ux to install the lower level OE from the latest set of HP-UX 11i v1 media, then use swremove to remove the unwanted OE bundle and its software. For example, to move from the 64-bit Mission Critical OE to the 64-bit default HP-UX 11i v1 OE: Step 1. As root, add default HP-UX 11i v1 OE: • • CD: /usr/sbin/update-ux -s /cdrom -y HPUX11i-OE DVD: /usr/sbin/update-ux -s /dvdrom -y HPUX11i-OE The -y option causes update-ux to ignore warning messages and complete the update. Step 2. Remove the Mission Critical software: /usr/sbin/swremove HPUX11i-OE-MC This command removes the IPD entries and software for the additional (superset) software in the Mission Critical OE, leaving the default HP-UX 11i v1 OE software intact. Updating from a Network Depot To update from a network depot on a remote system named netdepot, include the path to the depot in the update-ux command. The following example does an update to the HP-UX 11i v1 Enterprise OE: /usr/sbin/update-ux -s netdepot:/update/update_depot \ HPUX11i-OE-Ent Chapter 6 107 Updating to HP-UX 11i v1 Updating to HP-UX 11i v1 Updating Using Interactive Software Selection To interactively select software for an update, use the -i option. For example: /usr/sbin/update-ux -s /cdrom -i update-ux displays swinstall’s interactive user interface with software already selected to match the default update. Now you can change software selections. For example, you can select a non-default network driver or a web browser before performing the update. Because update-ux selects OS, networking, language, and diagnostic bundles by default, the interactive user interface provides a way to deselect the default software. CAUTION Do not combine -i and -x options in the same update-ux command. For help using swinstall in interactive mode, refer to the swinstall (1M) manpage or the Software Distributor Administration Guide. Updating to a 64-bit OS IMPORTANT Make sure that your system can support the 64-bit OS before running this command. For more information, see “Updating to 64-bit OS” on page 57. If you have decided to update an HP-UX 11i v1 32-bit system to a 64-bit OS, use the following command: • • 108 CD: /usr/sbin/update-ux -s /cdrom -a 64 DVD: /usr/sbin/update-ux -s /dvdrom -a 64 Chapter 6 Updating to HP-UX 11i v1 Updating to HP-UX 11i v1 Update Using match_target The following command using the match_target option installs the entire HPUX11i-OE bundle, including all OS, networking, CDE, and diagnostic bundles described in the previous example and any software selected by match_target. The software you want to install might not come from a bundle. • • Updating Existing OE Components Only CD: /usr/sbin/update-ux -s /cdrom \ -x match_target=true HPUX11i-OE DVD: /usr/sbin/update-ux -s /dvdrom -x match_target=true HPUX11i-OE The following command updates the same OE (HPUX11i-OE) and installs the OS, networking, CDE, and diagnostics bundles. • CD: /usr/sbin/update-ux -s /cdrom -x match_target=true HPUX11i-OE. • DVD: /usr/sbin/update-ux -s /dvdrom -x match_target=true HPUX11i-OE. The difference from the previous example is that the dot (.) following the OE bundle name installs the OE bundle wrapper, not the entire OE. With this variation, only those OE components that are already installed on your system get updated. Any new OE components and products are not installed. If no argument is specified, then only the OS and its components are updated. However, HP does not recommend using match_target to update your system to an OE without also specifying an argument because: Chapter 6 • If software arguments are not specified, match_target only installs filesets matching those already on your system. Filesets containing any new HP-UX 11i v1 functionality introduced are not selected. • Some software that is installed does not include bundle wrappers, making identification of software on the system more difficult. 109 Updating to HP-UX 11i v1 Updating to HP-UX 11i v1 Updating Selectable Software To update to HP-UX 11i v1 and include additional selectable bundles such as Software Package Builder bundle, like SwPkgBuilder, follow these steps: Step 1. If you want to install the HP-UX 11i v1 Foundation Operating Environment bundles listed in Appendix C, “HP-UX 11i v1 Software Bundles,” on page 177, plus the SwPkgBuilder Software Package Builder bundle, enter from the DVD media as root: /usr/sbin/update-ux -s /dvdrom HPUX11-OE SwPkgBuilder If you want only to update your system with a selectable software bundle, enter: /usr/sbin/update-ux -s /dvdrom SwPkgBuilder Step 2. Complete any configuration for HP software explained in the HP-UX 11i v1 Release Notes available on the Instant Information CD and at: http://docs.hp.com/hpux/os/11iv1 110 Chapter 6 Updating to HP-UX 11i v1 Post-Update Task: Configuring OE Applications Post-Update Task: Configuring OE Applications After updating to an HP-UX 11i v1 Operating Environment (OE), some OE products need post-installation configuration to make them functional. This may be indicated by a message logged in /var/adm/sw/swagent.log. Refer to each product’s installation instructions for details. The location of OE product documentation is listed in the HP-UX 11i v1 Release Notes, available on the Instant Information CD and at the HP Technical Documentation Web site: http://docs.hp.com Chapter 6 111 Updating to HP-UX 11i v1 The Next Step The Next Step Continue with the Chapter 7, “Installing HP Applications and Patches,” on page 113. 112 Chapter 6 7 Installing HP Applications and Patches This chapter describes how to install HP applications from the Applications DVD, and provides references for patching and patch management. Before you begin, make sure you have already completed installing or updating HP-UX. What You Will Find in This Chapter • “Installing HP-UX Applications” on page 114 • “HP-UX Patching and Patch Management” on page 117 • “The Next Step” on page 118 Time Estimate for This Chapter: Approximately 1-2 hours per patch (less if you download and install multiple patches in a single session) and 1-2 hours per application. Chapter 7 113 Installing HP Applications and Patches Installing HP-UX Applications Installing HP-UX Applications Your HP-UX 11i v1 media kit contains the HP-UX Applications DVD. The Applications DVD has optional development tools and system management software that you can choose to install as new or to update existing software on your system. TIP You can find the complete list of applications included in the HP-UX 11i v1 release in the HP Application Availability Matrix: http://www.software.hp.com/MATRIX Tips for Installing or Updating HP Applications Here are some tips for installing or updating HP applications: • HP-UX Applications DVDs have an ASCII file on each DVD called TABLE_OF_CONTENTS that lists all software products delivered with the Applications DVD. You can view this ASCII file with vi, emacs, or any other text editor. • To minimize the number of required reboots for installation of applications and patches you can use the same swinstall session. • For HP applications, documentation exists that explains how to install and use an application. The documents may include release notes, readme files, CD and DVD booklets, white papers, and guides. Refer to the Instant Information CD or go to the HP Technical Documentation Web site: http://docs.hp.com 114 Chapter 7 Installing HP Applications and Patches Installing HP-UX Applications Installing HP-UX Applications from the DVD You must boot HP-UX 11i v1 to install HP-UX application software products. Use the following procedure to install products from the Applications DVD: Step 1. Insert the Applications DVD in the DVD drive. Step 2. Mount the Applications DVD. To install software from the Applications DVD, you must mount the DVD as a file system that HP-UX 11i v1 can access: a. Determine the DVD device name. Use the ioscan -funC disk command to list disk devices, including the DVD devices. b. Create a mount point for the Applications DVD, if one does not yet exist. The mount point is a directory that HP-UX uses as an access point for the DVD. Often a /dvdrom directory is used. If this directory does not exist, create it using the mkdir /dvdrom command. c. Use the mount command to mount the DVD. Using the mount command, specify the DVD device name and mount point. For example, the following command mounts the /dev/dsk/c1t0d0 device as the /dvdrom directory: mount /dev/dsk/c1t0d0 /dvdrom Refer to the mount (1M) manpage for details. Step 3. To determine which products and versions are on your system, use the swlist command: /usr/sbin/swlist -l product Chapter 7 115 Installing HP Applications and Patches Installing HP-UX Applications Step 4. Use swinstall to install software from the Applications DVD. The following example uses swinstall to install software from the source mounted at /dvdrom: swinstall -i -s /dvdrom Refer to the swinstall (1M) manpage for details. Step 5. Select and install software from the Applications DVD. The swinstall program presents an interface for selecting and installing software from the DVD. Step 6. Unmount and eject the Applications DVD. You must unmount the DVD before you can eject it from the DVD drive. The DVD is automatically unmounted whenever the server reboots. Use the umount command to unmount the DVD. For example, umount /dvdrom unmounts the /dvdrom file system. Refer to the umount (1M) manpage for details. 116 Chapter 7 Installing HP Applications and Patches HP-UX Patching and Patch Management HP-UX Patching and Patch Management HP releases patches to deliver incremental updates to your system. Patches are best known for delivering defect fixes, but also deliver new functionality and features, enable new hardware, and update firmware. You can use HP-UX patches to update HP-UX software without having to completely reinstall your system application. For patching information, patch management strategies, and patch tools, refer to the Patch Management User Guide for HP-UX 11.x Systems at the HP Technical Documentation Web site: http://docs.hp.com/hpux/os/11iv1/ In addition, the IT Resource Center is a good resource for patches, tools, and information: http://itrc.hp.com NOTE Chapter 7 The HP patch resources are for HP-related patches only. To install or upgrade other vendor patches and applications, refer to the appropriate vendor documentation. 117 Installing HP Applications and Patches The Next Step The Next Step Continue with Chapter 8, “Verifying System Install or Update,” on page 119. 118 Chapter 7 8 Verifying System Install or Update This chapter provides steps to verify that your system is ready and back in production. Before you begin, make sure you have already completed either cold-installing or updating to HP-UX 11i v1. What You Will Find in This Chapter • “Verifying the HP-UX Cold-Install or Update” on page 120 • “Backing Up the System” on page 122 • “The Next Step” on page 123 Time Estimate for This Chapter: Approximately 2-3 hours to verify the installation or update of HP-UX. TIP Chapter 8 This chapter provides verification information for the HP-UX cold-install and update. To verify other vendor applications, refer to the appropriate vendor documentation. 119 Verifying System Install or Update Verifying the HP-UX Cold-Install or Update Verifying the HP-UX Cold-Install or Update To verify that HP-UX 11i v1 was installed or updated successfully, use the Software Distributor commands swlist and swverify, as described in this section. TIP For help with these commands, refer to the swlist (1M) and swverify (1M) manpages, and the Software Distributor Administration Guide, which is available on the Instant Information CD or at the HP Technical Documentation Web site: http://docs.hp.com/hpux/os/11iv1 Task 1: Listing All Software Installed on Your System Step 1. Run swlist to display a list of all software installed on your system: /usr/sbin/swlist You can control the detail level of the information displayed with the -l option. Step 2. Run swlist with options to display all bundles installed: /usr/sbin/swlist -l bundle Step 3. Run swlist with options to display all products installed or all file sets installed: /usr/sbin/swlist -l product /usr/sbin/swlist -l fileset Step 4. For a cold install, compare your list with the list of software products in the TABLE_OF_CONTENTS files on the HP-UX 11i v1 Operating Environment DVD and on the Applications DVD. 120 Chapter 8 Verifying System Install or Update Verifying the HP-UX Cold-Install or Update Task 2: Verifying Bundles Are Installed Step 1. Run swverify to verify that each bundle is intact: /usr/sbin/swverify bundlename For example, to verify that an installed English 64-bit OS is intact, enter the command: /usr/sbin/swverify HPUXBase64 Step 2. To verify all HP software on your system, enter the command: /usr/sbin/swverify \* The selection process determines dependencies of software. After the list, the system displays the following message: * Selection succeeded. Then, the analysis process verifies that each required file is loaded (existence and revision), that all required dependencies are met, and then it runs any available verification scripts for the product. After the analysis, the system displays the following message: * Analysis succeeded. If the analysis fails, either view the/var/adm/sw/swagent.log to review the analysis log or run the swjob command listed at the end of the swverify report sent to standard output. After the verification, the system displays the following message: * Verification succeeded. Chapter 8 121 Verifying System Install or Update Backing Up the System Backing Up the System Now that you have a solid system configuration, you need to back it up. This provides you with a stable configuration that you can use to rebuild the system, if necessary. For more information, see “Backing Up Your System” on page 69. 122 Chapter 8 Verifying System Install or Update The Next Step The Next Step Now that you have installed or updated your system and have all the HP applications and patches that you need, you must configure your system. You can find many of the configuration tasks in Managing Systems and Workgroups: A Guide for HP-UX System Administrators. The guide is available at the HP Technical Documentation Web site: http://docs.hp.com/hpux/os/11iv1/index.html Chapter 8 123 Verifying System Install or Update The Next Step 124 Chapter 8 Booting HP Servers and Workstations A Booting HP Servers and Workstations This appendix describes booting various HP servers and workstations using the built-in Boot ROM firmware interface. As explained here, the built-in boot process differs between newer and older workstations and servers. What You Will Find in This Appendix: NOTE • “Halting the Autoboot Process” on page 126 • “Booting Workstations” on page 127 • “Booting HP Servers” on page 129 • “Booting V-Class Systems” on page 132 • “Searching for Other Bootable Devices” on page 134 For help booting partitions in HP Superdome and S-Class servers, see the Managing HP Superdome Complexes manual, available on the Instant Information CD and on the Web: http://docs.hp.com/hpux/os/11i/ NOTE If you need help during the boot process, enter: help Appendix A 125 Booting HP Servers and Workstations Halting the Autoboot Process Halting the Autoboot Process 1. Make sure any external devices connected to the target system are switched ON. 2. Switch ON the target computer or cycle power. 3. Insert the install media into the drive. At the Stop Autoboot message: • Workstations: Press and hold down Esc. • Servers: Press and hold down Esc or any other key. 4. See the appropriate following section for your system’s boot process. If you need help during the boot process, enter: help 126 Appendix A Booting HP Servers and Workstations Booting Workstations Booting Workstations Newer workstation After stopping the boot process, the system displays a menu: boot menu Command Auto [boot|search] [on|off] Boot [pri|alt|scsi.addr] [isl] Boot lan[.lan_addr] [install] [isl] Chassis [on|off] Diagnostic [on|off] Fastboot [on|off] Help Information LanAddress Monitor [type] Path [pri|alt] [lan.id|SCSI.addr] Pim [hpmc|toc|lpmc] Search [ipl] [scsi|lan [install]] Secure [on|off] Description Display or set auto flag Boot from primary, alternate or SCSI Boot from LAN Enable chassis codes Enable/disable diagnostic boot mode Display or set fast boot flag Display the command menu Display system information Display LAN station addresses Select monitor type Change boot path Display PIM info Display potential boot devices Display or set security mode When you see the boot menu: Step 1. Enter: search Step 2. If the CD or DVD device is identified in the list shown by the search command, proceed with the following steps. Otherwise, check the device and cable connections and repeat the search. Step 3. Enter: boot scsi.x Use the SCSI address of the boot device for x. Step 4. If you see the prompt, Interact with IPL (y or n)?, enter: n (The bottom selections may not appear unless you hold down Esc.) Appendix A 127 Booting HP Servers and Workstations Booting Workstations Older workstation boot menu Older HP Workstations display a menu similar to this: b) Boot from specified device s) Search for bootable devices a) Enter Boot Administration mode x) Exit and continue boot sequence ?) Help Select from menu: To start a search for bootable devices, enter: s Older workstation search results Searching for Devices with Bootable Media. To terminate search, press and hold the ESCAPE key. Device Selection Device Path Device Type and Utilities P0 scsi.6.0 HP 2213A IPL P1 scsi.3.0 HP HP35480A IPL P2 scsi.0.0 TOSHIBA CD-ROM XM-3301TA IPL Enter boot selection, (h)elp, or e(x)it: You will see a list of Pn selections, as shown above. If your boot device does not appear in the search list: Step 1. Check the hardware. To exit, enter: x Step 2. To initiate another search, enter: s Step 3. At the prompt Enter boot selection, enter the Pn device selection for the device containing your install media. If you know the SCSI address of the device beforehand, you can skip the search and simply enter this at the Select from menu prompt: b scsi.x After choosing the boot path and loading the Ignite-UX tool, the Ignite-UX keyboard languages screen appears (if your system has a PC-style keyboard). From this point on, respond to the requests for information on this and successive screens. 128 Appendix A Booting HP Servers and Workstations Booting HP Servers Booting HP Servers As noted previously, you can halt the server autoboot process and redirect it to boot from the desired media device. To do so, press any key during the autoboot process to display a Main Menu: Newer server boot menu ----------------------- Main Menu -------------------------Command Description BOot [PRI|ALT|<path>] Boot from specified path PAth [PRI|ALT] [<path>] Display or modify a path SEArch [DIsplay|IPL] [<path>] Search for boot devices COnfiguration menu Displays or sets boot values INformation menu Displays hardware information SERvice menu Displays service commands DIsplay Redisplay the current menu HElp [<menu>|<command>] Display help for menu or command RESET Restart the system --------Main Menu: Enter command or menu > You only need to enter the initial capital letters for each command. Step 1. Determine the boot device that contains the install media. The Alternate Boot Device is typically set to the CD/DVD drive. If this is the case, enter: bo alt Step 2. To search for available boot devices, type: search (or sea) Appendix A 129 Booting HP Servers and Workstations Booting HP Servers Newer server search results Here is a typical output: Searching for potential boot device. This may take several minutes. To discontinue, press any key. Path Number Device Path Device Type --------------------------------------------------------------------P0 56/52.0 (dec) Seq. record access media P1 56/52.3 (dec) Seq. record access media P2 56/52.4 (dec) Random access media P3 56/52.6 (dec) Random access media Main Menu: Enter command or menu > For example, enter: bo pn where pn is the path number for the install device shown in the search output. You can also specify the device by the hardware path, such as 56/52.0, in place of the path number. Booting a server For Models 8x7, 845, 835, 870, and other older HP Servers, the boot display looks like this: Console path = 56.0.0.0.0.0.0 38.0.0.0.0.0.0 Primary boot path = 52.2.0.0.0.0.0 (dec) 34.00000002.0.0.0.0.0 Alternate boot path = 52.0.0.0.0.0.0 34.0.0.0.0.0.0 (dec) (hex) (hex) (dec) (hex) 64 MB of memory configured and tested. Autoboot from primary path enabled. To override, press any key within 10 seconds. Boot from primary boot path (Y or N)?> n Boot from alternate boot path (Y or N)?> Enter boot path, command, or ?> Step 1. Switch the system ON. Step 2. Press any key to stop the autoboot process. Step 3. Insert the install media. 130 Appendix A Booting HP Servers and Workstations Booting HP Servers Step 4. Determine the hardware path of the install device from your system administrator. (There is no search capability to determine this information on older HP server models). • If the primary path shown on your screen is not the same as that for the install device, respond with n to Boot from primary boot path. In this case, you will then be asked if you want to boot from the alternate path, which is typically set to the CD or DVD device. • If the primary path shown on your screen matches that for the install device, respond with: y • If neither the primary or alternate device paths correspond to that for the CD or DVD device, respond with n to both prompts. In this case, enter the hardware path of the device (for example, 52.3.0) at the prompt: Enter boot path, command, or ?> Step 5. To the question Interact with IPL (y or n)?, enter: n TIP To start over at this point, simply switch the system OFF and ON again. After choosing the boot path and the install utility loads, the keyboard languages screen appears (if your system has a PC-style keyboard). Respond to the requests for information on this and the following screens. Loading the install kernel takes 3 to 5 minutes. Appendix A 131 Booting HP Servers and Workstations Booting V-Class Systems Booting V-Class Systems V2200 system boot To boot the system from the install media, first power-up the system and console any external drive, as explained earlier. Portions of a typical V-Class boot display are shown below. To stop the system boot process and select the device with the install media, press any key within 10 seconds after you see “System is HP 9000 V2000 series”: OBP reboot SPP2000, POST version 3.1.4.0, compiled 1997/06/27 10:38:45 LAB #0001 Booting OBP... System is HP 9000 V2000 series Autoboot and Autosearch flags are both OFF or we are in HP core mode. Processor is entering manual boot mode. ... If the system is set to auto-boot, you will see this: Processor is starting the autoboot process. To discontinue, press any key within 10 seconds. ... Press any key to see the boot menu: Command AUto [BOot|SEArch ON|OFF] BOot [PRI|ALT|<path> <args>] BootTimer [time] CLEARPIM CPUconfig [<proc>] [ON|OFF] DEfault DIsplay ForthMode IO LS [<path>|flash] OS [hpux|sppux] PASSword PAth [PRI|ALT|CON] [<path>] PDT [CLEAR|DEBUG] PIM_info [cpu#] [HPMC|TOC|LPMC] RESET [hard|debug] RESTrict [ON|OFF] SCSI [INIT|RATE] [bus slot val] SEArch [<path>] SECure [ON|OFF] TIme [cn:yr:mo:dy:hr:mn[:ss]] VErsion Command: 132 Description Display or set the specified flag Boot from a specified path Display or set boot delay time Clear PIM storage Configure/Deconfigure Processor Set the sytem to defined values Display this menu Switch to the Forth OBP interface List the I/O devices in the system List the boot or flash volume Display/Select Operating System Set the Forth password Display or modify a path Display/clear Non-Volatile PDT state Display PIM of current or any CPU Force a reset of the system Display/Select restricted access to Forth mode List/Set SCSI controller parms Search for boot devices Display or set secure boot mode Display or set the real-time clock Display the firmware versions Appendix A Booting HP Servers and Workstations Booting V-Class Systems To determine the boot path, enter: pa Primary boot path Alternate boot path Console path Keyboard path Booting from the primary path = = = = 1/0:0.4.0 15/3 15/1 15/1 If your boot device (CD) is mounted at the primary path, enter: bo pri Device : /pci@fe,90000/symbios@0,0/sd@4,0:cntl Directory : LIF File : HPUX Arguments : hpux Loading : HPUX ............ %%xxxxxx%% bytes loaded. 101456 + 61440 + 864184 start 0xd01cc0 Boot: disc(1/0/0.4.0;0)/disc(1/0/0.4.0;0):INSTALL 7245824 + 1328048 + 706428 start 0x29168 HPUX: kernel load begins ... The install kernel then loads from the CD device. Appendix A 133 Booting HP Servers and Workstations Searching for Other Bootable Devices Searching for Other Bootable Devices If your CD is not mounted at the primary path, enter sea (search) at the command prompt to see a general listing of devices. The CD will be listed with its hardware path. For example: Command: sea Searching for Devices with Bootable Media. Device Selection Device Path Device Type ----------------------------------------------------------------P0 5/2:0.2.0 Disk : SEAGATE ST34371W 0484 P1 5/2:0.3.0 CD-ROM : TOSHIBA CD P2 1/2:0.9.0 Disk : SEAGATE ST19171W 0019 P3 1/0:0.4.0 Disk : SEAGATE ST19171W 0019 Command: For this example, boot the CD with: boot p1 The install kernel then loads from the CD device. NOTE The latest system firmware is required to support HP-UX Boot for the newer IO HBA Cards. The latest system firmware also corrects search problems with new bootable devices. 134 Appendix A Known Problems and Troubleshooting B Known Problems and Troubleshooting This section contains critical information for you to review before you start installing or updating to HP-UX 11i v1. Before installing or updating to HP-UX 11i, be sure to read this entire appendix as well as Read Before Installing or Updating to HP-UX 11i v1 CD booklet for additional late-breaking information. For information and patches on other known problems, go to the HP IT Resource Center web site: http://itrc.hp.com What You Will Find in This Appendix: • “Known Problems Discovered in This Release” on page 136 • “Install Known Problems” on page 137 • “Update Known Problems” on page 142 • “Common Install and Update Error and Warning Messages” on page 153 • “Problems Reading HP-UX 11i v1 DVD Media” on page 160 • “Problems Configuring HP-UX 11i v1” on page 163 • “Problems with Large Systems” on page 170 • “Un-installing HP-UX 11i v1” on page 171 • “Re-installing SD” on page 172 • “Recovering a Corrupt System” on page 173 • “Verifying and Adding Diagnostic Drivers” on page 174 • “Problems Affecting Non-C Locales” on page 175 Appendix B 135 Known Problems and Troubleshooting Known Problems Discovered in This Release Known Problems Discovered in This Release Table B-1 describes problems known to occur in the December 2004 HP-UX 11i v1 release. Table B-1 Known Install and Update Problems Problem Description/Action VxVM Disk Group Error During Install No validation is done on the disk group name to see if it conflicts with a disk group name currently imported on the system being installed. If the name conflicts with an imported disk group the creation of the extra disk group will fail. This is a feature of VxVM to prevent the creation of duplicate disk groups. If you do encounter this problem you will be presented with something like the following messages: vxvm:vxdg: ERROR: Disk group dg02: cannot create: Disk group exists and is imported ERROR: Command "/sbin/vxdg init dg02 dg0201=c17t12d0 dg0202=c17t13d0" failed. The configuration process has incurred an error, would you like to push a shell for debugging purposes? (y/[n]) To continue and ignore the error enter y and at the shell prompt enter exit 2 and press return. If you do not wish to continue the installation answer n. To resolve this issue, export VxVM disk groups before starting an install session if you plan on recreating them via the Installation User Interface. For more information, see the Ignite-UX FAQ: http://software.hp.com/products/IUX/faq.html 136 Appendix B Known Problems and Troubleshooting Install Known Problems Install Known Problems Table B-2 describes install problems known to occur in the HP-UX 11i v1 release. Table B-2 Known Install Problems Problem Description/Action “Kernel size is very large” Warning During Cold-Install During a cold-install, the following warning message may appear in your swagent.log: WARNING: Kernel size is very large. The kernel may not boot or may show decreased performance in small memory systems. Actual kernel size: 33118076 bytes * Build_Kernel: Complete * Boot_From_Client_Disk: Begin * Rebooting machine as expected. Please disregard the above warning, the check for the kernel size limit incorrectly uses the 32 MB value instead of the 64 MB value supported on HP-UX 11i v1. PHKL_27447 will correctly set the kernel size limit that gets checked during the creation of new HP-UX 11i v1 kernels. Known issues with OE Media Install Tools and Network Depots The Ignite-UX install tool on the OE media supports the use of network depots. However, network depots must match the media depots for the choices in the install tool to work properly. The Ignite-UX documentation also explains the setup and use of network depots without using the OE media for each installation. See the following web site for information on the Ignite-UX product: http://software.hp.com/products/IUX/ Appendix B 137 Known Problems and Troubleshooting Install Known Problems Table B-2 Known Install Problems (Continued) Problem Description/Action Kernel Build Fails on 64-bit Install On J2240 workstations having an SCSI floppy drive, cold-installing 64-bit OS will fail during the kernel build with an “unsatisfied symbols” error. Edit the /stand/system file to delete the floppy driver: • In the shell provided, use vi to edit the /stand/system file: vi /stand/system • Delete the line: sflop • Press Cntl D to close the window. The install process should now rebuild the kernel and complete successfully. The SCSI floppy drive will be non-operational, and is not supported on this system with 64-bit HP-UX 11i OS. vPars version A.02.03 Required for rp7405, rp7410 and rp8400 Servers with PDC Firmware Version 17.005 If you received an rp7405, rp7410 or rp8400 server with PDC firmware version 17.005 (overall firmware version 6.0), and you intend to use Virtual Partitions (vPars), you must obtain vPars version A.02.03. This latest version of vPars addresses compatibility issues with PDC firmware version 17.005. rp7405, rp7410 and rp8400 servers shipped from the factory on or after September 5, 2003 have PDC version 17.005 installed. PDC firmware version 17.005 is required to support the latest PCI and PCI-X I/O cards. If you have any questions, please contact your Customer Support Engineer for additional details and information. 138 Appendix B Known Problems and Troubleshooting Install Known Problems Table B-2 Known Install Problems (Continued) Problem Description/Action Visual Conference Product Does Not Install or Update with CD Media On the latest release of HP-UX11i v1, a checkinstall script error causes the Visual Conference product to be excluded from the TCOE Operating Environment. If you are installing or updating to the June 2004 TCOE Operating Environment from CD media (not DVD) you will be affected. You must reinstall the Visual Conference product after you’ve completed your cold install or update using swinstall. xntpd Fails to Start on Reboot After Installing GOLDQPK11i Patch Bundle After installing the GOLDQPK11i patch bundle, xntpd may fail to start after the initial reboot of the system. In your syslog.log file, you may encounter a similar message: Sep 23 14:46:23 <system_name> xntpd[1812]: tickadj = 625, tick = 10000, tvu_maxslew = 6 1875 Sep 23 14:46:23 <system_name> xntpd[1812]: precision = 6 usec Sep 23 14:46:23 <system_name> xntpd[1812]: bind() fd 4, family 2, port 123, addr 00000000, in_classd=0 flags=1 fails: Address already in use You might find a similar message in your rc.log file: Start time synchronization Output from ‘/sbin/rc2.d/S660xntpd start’: 23 Sep 14:46:23 ntpdate[1810]: the NTP socket is in use,exiting xntpd To resolve this problem: • Stop xntpd: /sbin/init.d/xntpd stop • Verify xntpd is down: ps -ef | grep xntpd • Start xntpd /sbin/init.d/xntpd start Appendix B 139 Known Problems and Troubleshooting Install Known Problems Table B-2 Known Install Problems (Continued) Problem Description/Action IETHER-00 Networking Driver Requires Critical Fixes from PHNE_29947 HP has released PHNE_29947 to address critical defects with the IETHER driver in the IEther-00 bundle (11.11.05) that is delivered with the HP-UX 11i v1 OE update for June 2004. The IETHER driver supports the built-in LAN on the C8000 workstation, along with the add-in GigEthernet cards (A7011A and A7012A). You can obtain PHNE_29947 from the IT Resource Center (ITRC) from the following URL: http://itrc.hp.com 140 Appendix B Known Problems and Troubleshooting Install Known Problems Table B-2 Known Install Problems (Continued) Problem Description/Action System Console "kthread table full" or "fork failed" Messages This section was modified in the March 2003 release to reflect how the maxusers tunable value varies depending on the type of system you have. After a successful cold install, the system starts displaying console messages such as kthread table full or fork failed console These messages are also logged in /var/adm/syslog.log. This is caused by the maxusers kernel tunable not set at high enough value. An example of what you might see is the following message logged onto the system console: kthread: table is full You would also see the following message being logged in /var/adm/syslog.log: Jan 30 09:21:39 sd2600 vmunix: kthread: table is full To correct this, increase the maxusers tunable: • Log on as root and edit /stand/system and add the following value (depending on your system): — Large 64-way systems (Superdome): maxusers 400 — 16-way systems: maxusers 200 Consult your HP Customer Engineer for setting the appropriate values on your system • Run the following commands: mk_kernel -v -o /stand/vmunix kmupdate reboot -r Appendix B 141 Known Problems and Troubleshooting Update Known Problems Update Known Problems Table B-3 describes update problems known to occur in the HP-UX 11i v1 release. Table B-3 Known Update Problems Problem Description/Action Ignore error message: Pay Per Use Failed During upgrade of your HP-UX 11i v1 (B.11.11) system, the following error message is in the rc.log: /sbin/rc[41]: /sbin/rc2.d/S700ppu: not found. "/sbin/rc2.d/S700ppu start" FAILED Or you may see this message in the console log: Initialize Pay Per Use............ Failed These messages are extraneous, do not cause any ill effects, and you can ignore them. DMI/SCR Become Unbundled After Update After updating to the September 2003 release (or later) of HP-UX 11i v1, you may encounter a warning after running the swlist command indicating that DMI/SCR (B6816AA) was unbundled during the update: # # Product(s) not contained in a Bundle: # DMI B.11.11.30 Interface for HP-UX SCR B.11.11.30 Configuration Repository Desktop Management System You will encounter this warning if DMI/SCR (B6816AA) was installed prior to updating. DMI/SCR will continue to work after the update. If you plan to continue using DMI/SCR, HP recommends that you download the latest version of DMI from http://software.hp.com. Starting with the September 2003 release, DMI will no longer be shipped as part of the Operating Environments. Instead, it will be available and supported as a web-only product. 142 Appendix B Known Problems and Troubleshooting Update Known Problems Table B-3 Known Update Problems (Continued) Problem Description/Action Unsupported Upgrade of ServiceControl Manager Causes SCR Error During Update While updating an HP-UX 10.20 system to either the Foundation, Enterprise or Mission Critical Operating Environment, you may encounter the following error messages in swagent.log appearing to affect SCR: ERROR: [300076] Cannot delete the definition for product "SCR" from the target "/". The product is not empty, it still contains filesets. These error messages are caused by an unsupported upgrade of ServiceControl Manager 3.0 from a version of SCM earlier than version 2.5. SCM 3.0 only supports upgrades from version 2.5 or higher. Because this is an unsupported upgrade path, no changes will be made to either SCR or ServiceControl Manager. If you are updating an HP-UX 10.20 system to either the Foundation, Enterprise, or Mission Critical Operating Environment, and you have a version of ServiceControl Manager earlier than version 2.5, you will encounter these errors. To resolve this problem: • Use the swremove (1M) command to remove the existing ServiceControl Manager bundle from the system • With your HP-UX 11i v1 media, use the swinstall (1M) command to install the latest version of ServiceControl Manager (B8339BA) on your system. Appendix B 143 Known Problems and Troubleshooting Update Known Problems Table B-3 Known Update Problems (Continued) Problem Description/Action Boot Error Messages Appear After Updating from HP-UX 11.0 (with MirrorDisk/UX Installed) to HP-UX 11i v1 TCOE If you are updating to HP-UX 11i v1 TCOE from HP-UX 11.0 with MirrorDisk/UX installed, the following error message may appear during the boot process: /sbin/bcheckrc: Checking for LVM volume groups and Activating (if any exist) Volume group "/dev/vg00" has been successfully changed. vgsync: Error, "vgsync" is not a valid LVM command. vxfs fsck: sanity check: root file system OK (mounted read/write) Checking hfs file systems /sbin/fsclean: /dev/vg00/lvol1 (mounted) ok HFS file systems are OK, not running fsck Checking vxfs file systems /dev/vg00/lvol8 : vxfs fsck: sanity check: /dev/vg00/lvol8 OK /dev/vg00/lvol3 : vxfs fsck: sanity check: root file system OK (mounted read/write) /dev/vg00/lvol4 : vxfs fsck: sanity check: /dev/vg00/lvol4 OK /dev/vg00/lvol5 : vxfs fsck: sanity check: /dev/vg00/lvol5 OK /dev/vg00/lvol6 : vxfs fsck: sanity check: /dev/vg00/lvol6 OK /dev/vg00/lvol7 : vxfs fsck: sanity check: /dev/vg00/lvol7 OK Cleaning /etc/ptmp... This error message may appear during reboot after the updating from HP-UX 11.0 with MirrorDisk/UX installed to HP-UX 11i v1 TCOE. MirrorDisk/UX for HP-UX 11i is not included with TCOE. As a result, when the HP-UX 11.0 version of MirrorDisk/UX is removed from the system, the commands associated with HP MirrorDisk/UX are not properly deleted. This causes the LVM startup script to believe that HP MirrorDisk/UX is installed on the system. To resolve this problem you must purchase and install MirrorDisk/UX for HP-UX 11i v1. 144 Appendix B Known Problems and Troubleshooting Update Known Problems Table B-3 Known Update Problems (Continued) Problem Description/Action ApacheStrong Becomes Unbundled After Update After updating to the June 2003 release of HP-UX 11i v1, you may encounter a warning after running the swlist command, indicating that ApacheStrong was unbundled during the update: # # Product(s) not contained in a Bundle: # ApacheStrong 1.3.26.06.09 HP Apache-based Web Server with Strong (128bit) Encryption If you previously installed ApacheStrong 1.3.x prior to updating to this release, you may encounter this warning. You can safely disregard this warning. The HP-UX Web Server Suite and ApacheStrong 1.3.x will function properly. parmgr.1m Errors on MCOE Update from HP-UX 11.0 to HP-UX 11i v1 After updating from HP-UX 11.0 to HP-UX 11i v1 MCOE, the following mtime, stime, and permission errors may appear in your swverify.log file: * [140112] Checking files for fileset "OS-Core.CORE-JPN-S-MAN,l=/,r=B.11.11". ERROR: [40258] File "/usr/share/man/ja_JP.SJIS/man1m.Z/parmgr.1m" should have mode "444" but the actual mode is "555". ERROR: [40263] File "/usr/share/man/ja_JP.SJIS/man1m.Z/parmgr.1m" should have mtime "974188800" but the actual mtime is "1032497544". ERROR: [40265] File "/usr/share/man/ja_JP.SJIS/man1m.Z/parmgr.1m" should have size "3244" bytes but the actual size is "3472" bytes. ERROR: [140113] Fileset "OS-Core.CORE-JPN-S-MAN,l=/,r=B.11.11" had file errors. You can disregard these errors. The parmgr (1M) manpage will work correctly. Appendix B 145 Known Problems and Troubleshooting Update Known Problems Table B-3 Known Update Problems (Continued) Problem Description/Action HP Apache May Hang On Reboot after System Update from Golden System Image (GSI) Depot When upgrading from a GSI-installed system containing an OE with HP Apache 2.0, some systems may hang while attempting to shutdown the Apache Web Server. The problem is caused by an obsolete PID from the httpd daemon being copied from the GSI Golden Image Depot to the client system. You may be affected if you are upgrading from a GSI HP-UX 11.0 Depot containing HP Apache 2.0 to HP-UX 11i v1. GSI Depot (Server): 1. Shut down your HP Apache Web Server before creating the GSI Depot by typing /opt/hpapache2/bin/apachectl stop 2. Verify that the following file has been deleted: /opt/hpapache2/logs/httpd.pid Client System: Delete the following file (if present) after installing the GSI Depot and before an update install: /opt/hpapache2/logs/httpd.pid MLIB 8.3 Produces Warning During Update When updating from MLIB 8.1 (or earlier) to MLIB 8.3 the following warning may appear in the /var/adm/sw/swagent.log: WARNING: Incomplete definition for the product "MLIBPROD", beginning at line 44452. The following attributes are not defined:filesets the filesets contained in the product You can disregard this warning message; there is no problem with the installation. 146 Appendix B Known Problems and Troubleshooting Update Known Problems Table B-3 Known Update Problems (Continued) Problem Description/Action X11MotifDevKit Produces Incompatible Error After Upgrade from HP-UX 10.20 After updating from HP-UX 10.20 to HP-UX 11i v1, the following errors may appear in your swverify.log: ERROR: [140167] The product "X11MotifDevKit,l=/,r=B.10.20.02" is not compatible with this system's architecture or operating system. * [140061] Configured X11MotifDevKit.X11R6-PRG,l=/,r=B.10.20.02 [140155] The corequisite "X11.X11R6-SHLIBS,r=B.10.*" for fileset "X11MotifDevKit.X11R6-PRG,l=/,r=B.10.20.02" cannot be successfully resolved. ERROR: [140151] The dependencies for fileset "X11MotifDevKit.X11R6-PRG,l=/,r=B.10.20.02" cannot be resolved (see previous lines). * [140112] Checking files for fileset "X11MotifDevKit.X11R6-PRG,l=/,r=B.10.20.02". WARNING: [40257] Directory "/" should have mode "555" but the actual mode is "755". WARNING: [40261] Directory "/" should have group,gid "other,1" but the actual group,gid is "root,0". WARNING: [40259] Directory "/usr/newconfig" should have owner,uid "root,0" but the actual owner,uid is "bin,2". WARNING: [40261] Directory "/usr/newconfig" should have group,gid "other,1" but the actual group,gid is "bin,2". WARNING: [140114] Fileset "X11MotifDevKit.X11R6-PRG,l=/,r=B.10.20.02" had file warnings. ERROR: [140043] Verify failed X11MotifDevKit.X11R6-PRG,l=/,r=B.10.20.02 The problem is differences in the X11MotifDevKit between HP-UX 10.20 and HP-UX 11i. You may experience this problem if you are updating from HP-UX 10.20 to HP-UX 11i v1, and have not updated your system with the latest HP-UX 10.20 patch bundles. After you have updated your system to HP-UX 11i v1, re-install the HP-UX 11i v1 Developer’s Kit located in the HP-UX 11i v1 Application Software media kit (CD/DVD). For servers, install B3394BA and for workstations, install B3392BA. Appendix B 147 Known Problems and Troubleshooting Update Known Problems Table B-3 Known Update Problems (Continued) Problem Description/Action OpenView SNMP Agent Produces Error with Upgrade to HP-UX 11i v1 Due to a preinstall script error, customers upgrading to HP-UX 11i v1 may see the following error: * [140184] Installing fileset "OVSNMPAgent.MASTER,r=B.11.11" (54 of 1293). * [20255] Running "postinstall" script for fileset "OVSNMPAgent.MASTER". * [20255] Running "preinstall" script for fileset "OVSNMPAgent.SUBAGT-HPUNIX". kill: 616: The specified process does not exist. NOTE: You may need to restart SNMP agents. The error is caused by the kill command trying to end a process that is already terminated. When the OVSNMPAgent.MASTER fileset is installed, it invokes a kill command to terminate any existing SNMP agents. The next fileset, OVSNMPAgent.SUBAGT-HPUNIX, also attempts to terminate any SNMP Agent processes. If you are migrating from HP-UX 10.20 or HP-UX 11.0 to HP-UX 11i v1, you may receive this error message during the installation of the OpenView SNMP bundle. You can safely ignore this message. 148 Appendix B Known Problems and Troubleshooting Update Known Problems Table B-3 Known Update Problems (Continued) Problem Description/Action “Initialize of the ITO Control Agent failed” Error During update-ux Session Beginning in June 2002, the ITO-SE single system event management component was removed from the GlancePlus Pak 2000 product. If you are updating from HP-UX 10.20 or HP-UX 11.0 and you have a version of GlancePlus Pak 2000 released prior to June 2002, update-ux will try to remove the ITO-SE component prior to updating to a newer GlancePlus Pak. You may encounter the following error when update-ux removes the file sets belonging to the ITO-SE component: * Beginning the Unconfigure Execution Phase. * Filesets: 3 * Files: 163 * Kbytes: 15427 * Running remove setup command /usr/lbin/sw/remove_setup. Error opcctla (Control Agent)(14791) : Initialize of the ITO Control Agent failed. (OpC30-1036) Can't lookup (OpC20-108) Can't lookup (OpC20-108) Stopping all /usr/bin/ps: /usr/bin/ps: servers: Communications failure (dce / rpc). servers: Communications failure (dce / rpc). ITO Agent processes... (OpC30-1192) couldn't get console device alias not enough memory for hash table No action required. The ITOAgent unconfigure script generates the error prior to the file sets being removed. Appendix B 149 Known Problems and Troubleshooting Update Known Problems Table B-3 Known Update Problems (Continued) Problem Description/Action Firmware Patches Should Not Be Included in Cold-Install or Update Session If you are migrating from either HP-UX 10.20 or HP-UX 11.0, HP strongly recommends you do not include firmware patches while running a cold-install or update session. The following systems are affected: • A-Class • L-Class • N-Class Many of the HP-UX 11i v1 firmware patches rely on HP-UX 11i v1 tools and system calls. During the cold-install or update process, your system is still running either the HP-UX 10.20 or HP-UX 11.0 kernel. The firmware installation fails because of system call differences between the HP-UX 11i v1 kernel and older kernel versions. HP strongly recommends that you install any firmware patches after you have completed the cold-install or update process and your system is running HP-UX 11i v1. Specific HP-UX 11i v1 firmware patches are available at the following website: http://itrc.hp.com Analyzing Log Files To help identify a problem with running update-ux, remember that errors are logged in two separate log files: • update-ux errors: /var/adm/sw/update-ux.log and /var/adm/sw/swagent.log • swinstall errors: /var/adm/sw/swinstall.log and /var/adm/sw/swagent.log SD commands log errors to /var/adm/sw/swagent.log, plus their own log. Simply checking more than one log file may reveal the problem you are troubleshooting. 150 Appendix B Known Problems and Troubleshooting Update Known Problems Table B-3 Known Update Problems (Continued) Problem Description/Action Update Fails if nstrpty Kernel Parameter Set as a Formula If the value of the nstrpty kernel parameter is specified as a formula (for example, nstrpty (NPTY*2)), then updating to HP-UX 11i will fail with this error: /var/tmp/BAAa10554/catalog/Streams-TIO/STRTIO-KRN/posti nstall[82]: (NPTY): The specified number is not valid for this command. ERROR: The “postinstall” script for “Streams-TIO.STRTIO-KRN” failed (exit code “1”). The script location was “/var/tmp/BAAa10554/catalog/Streams-TIO/STRTIO-KRN/post install”. To prevent this, convert the value of nstrpty to a number. To check the kernel parameters, run SAM and select: Kernel Configuration -> Configurable Parameters If the nstrpty kernel parameter is specified as a formula, then before you update, use SAM (Kernel Configuration -> Configurable Parameters) to change the formula to a numeric value. You do not need to rebuild the kernel or reboot the system. Appendix B 151 Known Problems and Troubleshooting Update Known Problems Table B-3 Known Update Problems (Continued) Problem Description/Action Kernel Build Failure When updating a workstation running on a HP-UX 10.20 32-bit OS to HP-UX 11i 32-bit OS/OE, the update may fail if a USB driver is configured on the system. This will not occur when updating to HP-UX 11i 64-bit OS. If this occurs, update-ux displays this message on the console before quitting: Loading the kernel... /usr/ccs/bin/ld: Unsatisfied symbols: wsio_get_service (code) Stop... ERROR: The kernel build failed... Remove the USB drivers and repeat the update: • As root, edit /stand/system: vi /stand/system • Find and delete all USB drivers: usbd, hsd, hub, hid • Save the system file and quit the editor. • Continue the update by entering: update-ux -kernel_build HP A3740A Fibre Channel PCI Tachyon Not Supported 152 The HP A3740A Fibre Channel PCI Tachyon adapter is not supported on HP-UX 11i v1. Before you install HP-UX 11i v1, please replace any A3740A PCI adapters in your system with A5158A PCI 1 GB Tachyon TL adapters or A6795A PCI 2 Gb Tachlite adapters. Then connect any Fibre Channel Mass Storage devices previously connected to A3740A adapters to either of the adapters. Appendix B Known Problems and Troubleshooting Common Install and Update Error and Warning Messages Common Install and Update Error and Warning Messages As an install or update progresses, you will see messages relating to the progress being entered into the log file. These messages usually refer to normal behavior. ERROR and WARNING messages, however, have the following significance: ERROR Indicates a serious problem, usually requiring action from the user in order to proceed with an installation. WARNING Indicates something out of the ordinary and may require action. If you see a message or experience unusual behavior, see the following pages for likely solutions. This section includes some update-ux error messages and typical recovery actions. Table B-4 describes common install and update error and warning messages known to occur in the HP-UX 11i v1 release. Table B-4 Common Install and Update Error and Warning Messages Problem Description/Action Selected Locale Not Available Warning! One or more of your selected locales are not available. Please invoke the commands "locale" and "locale -a" to verify your selections and the available locales. Continuing processing using the "C" locale. Ignore this message which appears when updating from HP-UX 10.20 in every locale except C. The local environment, such as Japanese, is temporarily disabled during the update session. Appendix B 153 Known Problems and Troubleshooting Common Install and Update Error and Warning Messages Table B-4 Common Install and Update Error and Warning Messages Problem Description/Action Multiple OE Errors Installing both the HP-UX 11i Operating Environment and the Enterprise Operating Environment on the same system is not a standard update path. If you continue with this operation, use the swremove(1M) to remove the Enterprise Operating Environment after the update is complete. Complete the update. Then remove the HPUX11i-OE-Ent bundle using the swremove command. Changing from the Enterprise Operating Environment to the Mission Critical Operating Environment at the same time as you change from a 32 bit OS to a 64 bit OS is not a tested operation... Although you can change OS word-width and move from one OE to another at the same time, we recommend performing separate operations. In this case: • Update OS to new word-width: /usr/sbin/update-ux -s /cdrom -a 64 • Install the desired OE: /usr/sbin/update-ux -s /cdrom HPUX11i-OE-MC For more about changing OEs, see “Adding or Upgrading an OE” on page 106. 154 Appendix B Known Problems and Troubleshooting Common Install and Update Error and Warning Messages Table B-4 Common Install and Update Error and Warning Messages Problem Description/Action Servicecontrol Manager Filesets May Indicate Incorrect Permissions Some Servicecontrol Manager directories may indicate that they have incorrect permissions during an update to the June 2004 version of HP-UX 11i v1. You can safely ignore these warnings. Servicecontrol Manager will work correctly. These warnings have been fixed for subsequent Servicecontrol Manager releases.You may encounter the following warning messages in your swagent.log: * [140112] Checking files for fileset "SysMgmtAgent.MX-AGENT,l=/,r=B.03.00.07". WARNING: [40259] Directory "/opt/mx/bin" should have owner,uid "root,0" but the actual owner,uid is "bin,2". WARNING: [40259] Directory "/opt/mx/lib" should have owner,uid "root,0" but the actual owner,uid is "bin,2". WARNING: [40259] Directory "/opt/mx/newconfig" should have owner,uid "root,0" but the actual owner,uid is "bin,2". WARNING: [40259] Directory "/opt/mx/newconfig/etc" should have owner,uid "root,0" but the actual owner,uid is "bin,2". WARNING: [40259] Directory "/opt/mx/newconfig/etc/opt" should have owner,uid "root,0" but the actual owner,uid is "bin,2". WARNING: [40259] Directory "/opt/mx/newconfig/etc/opt/mx" should have owner,uid "root,0" but the actual owner,uid is "bin,2". WARNING: [40259] Directory "/opt/mx/newconfig/etc/opt/mx/config" should have owner,uid "root,0" but the actual owner,uid is "bin,2". WARNING: [40259] Directory "/var/opt/mx/config" should have owner,uid "root,0" but the actual owner,uid is "bin,2". WARNING: [40259] Directory "/var/opt/mx/data" should have owner,uid "root,0" but the actual owner,uid is "bin,2". WARNING: [40259] Directory "/var/opt/mx/logs" should have owner,uid "root,0" but owner,uid is "bin,2". Appendix B 155 Known Problems and Troubleshooting Common Install and Update Error and Warning Messages Table B-4 Common Install and Update Error and Warning Messages Problem Description/Action Warning Displays WARNING: There were errors installing from the first depot. See the /var/adm/sw/swagent.log for details. WARNING: Continuing could cause the OS update to fail Do you want to continue ? (y/n) Press y to continue the update. Afterward, review /var/adm/sw/swagent.log. Disk Space Usage Error To perform this OS update, it is required that the xxx partition have at least yyy KB of free space and it currently has zzz KB of free space Reconfigure your disk per the minimum recommendations in the message. Then run the update-ux command again. swinstall Analysis Error The analysis phase failed while installing from the first depot. See the /var/adm/sw/swagent.log for details. The swinstall analysis on software from HP-UX 11i v1 CD1 failed and update-ux quit. Correct the indicated problem and run the command again. Post-update swverify Error After updating your system to an HP-UX 11i v1 OE, run swverify to ensure that all application software previously on your system is still compatible with the new OS. If you get an error like this: The product "xyz,l=/,r=B.xx.xx" is not compatible with this system’s architecture or operating system. The indicated software (xyz) has not been updated to HP-UX 11i. To update the software, mount the HP-UX 11i v1 Applications CD that contains the software and install the new version using the swinstall command. For more details, see Chapter 7. 156 Appendix B Known Problems and Troubleshooting Common Install and Update Error and Warning Messages Table B-4 Common Install and Update Error and Warning Messages Problem Description/Action Root (/) Volume Lock Error If update-ux quits after you extended a volume size, you may see an error containing these lines: ERROR: The command: /var/adm/sw filter /var/adm/sw/update-ux/swinstall... This error will be logged in /var/adm/sw/swinstall.log: Error: Cannot lock “/” because another command hold a conflicting lock ... This error indicates that other processes have locked the root volume, preventing update-ux from completing a successful update. Wait 10 minutes and retry the update-ux command again. EISA 100BT Warning Message When you remove an EISA 100BT product from a system or update a system having EISA 100BT to any later releases of HP-UX, you may find the following message in the /var/adm/sw/swagent.log file: Running remove setup command /usr/lbin/sw/remove_setup. /dev/diag/ether* not found. This behavior is present in HP-UX 10.20 to HP-UX 11i (B.11.11) versions of this product. Presence or absence of this file on a system will not have any impact on this product. You may safely ignore this message. Appendix B 157 Known Problems and Troubleshooting Common Install and Update Error and Warning Messages Table B-4 Common Install and Update Error and Warning Messages Problem Description/Action PHSS_29731 X/Motif Runtime Periodic Patch Could Not Be Installed During a cold install or update, you may encounter the following warning: WARNING: [140394] The patch ‘PHSS_29731, l=/, r=1.0’ contains some filesets which are superseded and some filesets which are not superseded. The superseding patch may be incorrect or may need to be reapplied. This warning is caused by the following items being installed during the same session: • X11 • TechPrintServ • PHSS_29371 (note that this is the "superseding patch" that the warning text refers) You can find the X11 and TechPrintServ filesets in the Operating Environments (OEs) on the core media, and you can find patch PHSS_29371 in the June 2004 Quality Pack patch bundle on the Support Plus media. Patch PHSS_29371 must be reinstalled. 158 Appendix B Known Problems and Troubleshooting Common Install and Update Error and Warning Messages Table B-4 Common Install and Update Error and Warning Messages Problem Description/Action Using Ignite-UX with HP-UX 11i v1 OEs and Patch Bundles In order for Ignite-UX to properly load patch bundles, the configuration file for the install depot needs to be modified. The sd_software_list definition needs to be removed from the bundle definitions for all patch bundles in the depot. It is important that all the patch bundles in the configuration file are modified to allow for patch supersession to work properly. The following patch bundles are supported for installation with the desired HP-UX 11i v1 OE from a single depot source: BUNDLE11i HWEnable11i FEATURE11-11 GOLDAPPS11i GOLDBASE11i If you have added any custom patch bundles to your install depot, the sd_software_list definition for those bundles should be removed also. With the sd_software_list definition removed, SD will use autoselect_patches to resolve which patches should be installed. Appendix B 159 Known Problems and Troubleshooting Problems Reading HP-UX 11i v1 DVD Media Problems Reading HP-UX 11i v1 DVD Media The HP-UX 11i v1 DVD media contains large volumes of data that may cause your DVD device to fail while reading the DVD media contents during an update. This particularly affects you if you use Update-UX or other Software Distributor (SD) tools. For example, you may encounter similar error messages if you attempt to read DVD media with a large volume of data from Update-UX: ERROR: File "/dvd/catalog/SOE/SOE.2/INFO": No such file or directory(2). Cannot copy it to file "/var/tmp/BAAa04482/catalog/SOE/SOE.2/INFO". ERROR: File "/var/tmp/BAAa04482/catalog/SOE/SOE.2/INFO" does not exist. ERROR: The catalog files for product "SOE,r=B.11.11" failed to load. Check the above output for details. ERROR: Cannot continue the Analysis Phase until the previous errors are corrected. To resolve this problem, do one of the following: • For HP-UX 11.00 or 11.11, install the appropriate patches listed in this section before you update to the latest version of HP-UX 11i v1 (recommended). • For HP-UX 10.20, use the pfs_mount (1M) command to mount the DVD. To patch your system, use the following patches (patch descriptions are in parentheses) for your current OS version: NOTE The listed HP-UX 11i v1 patches are included in the December 2003 (and later) version of the HP-UX 11i v1 install kernel. If you are planning to cold-install HP-UX 11i v1 (December 2003 or later), you do not need to install these patches. 160 Appendix B Known Problems and Troubleshooting Problems Reading HP-UX 11i v1 DVD Media Patches for Systems Currently Running HP-UX 11i v1 • PHKL_26269 (11.11 Rock Ridge extension for ISO-9660) • PHKL_28025 (11.11 Rock Ridge extension for ISO-9660) • PHCO_25841 (11.11 Add Rock Ridge extension to mount_cdfs (1M)) Patches for Systems Currently Running HP-UX 11.0 • PHKL_26450 (11.00 Rock Ridge extension for ISO-9660) • PHKL_28060 (11.00 Y2k; Rock Ridge extension for ISO-9660) • PHCO_26449 (11.00 Add Rock Ridge extension to mount_cdfs (1M)) Patches for Systems Currently Running HP-UX 10.20 No patches are available. Please note that Update-UX fails when updating from HP-UX 10.20 to HP-UX 11i v1 (B.11.11.0412) using CD media. If you are using CDs to update an HP-UX 10.20 system to the HP-UX 11i v1 December 2004 (B.11.11) Operating Environments, the update-ux command will fail because HP-UX 10.20 does not support Rockridge extension. The following is the output from the update-ux.log: NOTE: The fileset "SW-GETTOOLS.SD-SUPPORT,r=B.11.11.0406" is already installed. If you wish to reinstall this fileset, change the "reinstall" option to "true". * Reading source for file information. ERROR: File "/cdrom/catalog/SOE/SOE.2/INFO": No such file or directory (2). Cannot copy it to file "/var/tmp/BAAa03877/catalog/SOE/SOE.2/INFO". ERROR: File "/var/tmp/BAAa03877/catalog/SOE/SOE.2/INFO" does not exist. ERROR: The catalog files for product "SOE,r=B.11.11" failed to load.Check the above output for details. ERROR: Cannot continue the Analysis Phase until the previous errors are corrected. To resolve this issue, first update to the desired HP-UX 11i v1 December 2003 Operating Environments and then update to the desired HP-UX 11i v1 December 2004 Operating Environments. Appendix B 161 Known Problems and Troubleshooting Problems Reading HP-UX 11i v1 DVD Media Determining Whether You Need to Install the Patches To determine whether your system already has the listed patches installed, run the following: /usr/sbin/swlist -l patch | grep patch_name where patch_name is one of the listed patches for your operating system version. If nothing is printed to standard output, you need to install the patches from one of the following sources: • The GOLDBase11i bundle on the Support Plus CD (June 2003 or later) for HP-UX 11i v1 • The QPK1100 bundle on the Support Plus CD (September 2003 or later) for HP-UX 11.0 • The IT Resource Center website (requires login): http://itrc.hp.com • The anonymous IT Resource Center FTP site: ftp://ftp.itrc.hp.com 162 Appendix B Known Problems and Troubleshooting Problems Configuring HP-UX 11i v1 Problems Configuring HP-UX 11i v1 Read these items before installing or updating to HP-UX 11i v1. Kernel Build Warnings for krm Module During Cold-Install or Update During a cold-install or update, you may encounter a warning message in either /var/opt/ignite/local/install.log or /var/adm/sw/update-ux.log indicating that debug information may be corrupted. The warning may appear as follows: Generating module: krm... /usr/lbin/sw/bin/mkdir -p /stand/build Compiling /stand/build/conf.c... Loading the kernel... (Warning) Optimizing ADDILs in the presence of the debug information. Debug information may be corrupted (1594) Generating kernel symbol table... What To Do You may safely disregard this warning cdrecord Application Requires Patch The cdrecord application delivered with the XCDROAST-RUN fileset in the TC-OpenSource product requires kernel patch PHKL_24283 or one of its successors (including PHKL_26410 and PHKL_27225) Appendix B 163 Known Problems and Troubleshooting Problems Configuring HP-UX 11i v1 Enabling AutoFS on High Availability Servers Can Cause NFS Packages to Be Dropped Restarting NFS clients (with nfs.client stop/start) or NFS servers (with nfs.server stop/start) while NFS packages are running on the High Available (HA) server will cause the exported file systems that tie to NFS packages to be dropped. This is because the SG-NFS exported file systems are handled interactively and they are not in the /etc/exports file. When stopping NFS clients or NFS servers, it will unexport all the file systems on the system through the /usr/sbin/exportfs -au command. The file systems will be re-exported if they have the entries in /etc/exports file at the starting phase again, but not the file systems exported interactively by the NFS packages. How Do You Know You are affected if you enable AutoFS on an HA server. if This Affects You? What To Do Enabling AutoFS on the HA NFS server needs to be done with caution. However, this kind of configuration is fully supported if one of these two actions is taken before stopping the AutoFS daemon: 1. Manually move all NFS packages to the adoptive server node. 2. Halt all NFS packages. The Auto FS daemon can be stopped either with the kill -9 command, the nfs.client script, or the nfs.server script. Once the AutoFS daemon is restarted, the NFS packages can be restarted or manually moved back to the server node. AutoFS can be restarted either with the /usr/sbin/automountd command or the nfs.client script. 164 Appendix B Known Problems and Troubleshooting Problems Configuring HP-UX 11i v1 Hardware Information Not Captured on Systems with Floppy Drive On systems with a floppy-disk drive attached, hardware information will not be captured in the System Configuration Repository (SCR) under HP-UX 11i. After updating a system with a floppy drive from 10.20 to 11i, you will find a core file in /usr/dmi/bin, and hpuxci (HP-UX DMI Component Instrumentation) will not be running. How Do You Know This problem affects you if there is a floppy drive attached to (or installed If This Affects in) your system, and you use the System Configuration Repository (SCR) You? to store hardware information. Since the hpuxci is not running, hardware information will not be captured. The problem occurs if /dev/floppy exists. What To Do A fix for the problem will be made available in the earliest follow-up patch release for 11i. In the meantime, if you depend on the SCR, you should either not update to 11i, or remove the floppy drive. NOTE If /dev/floppy exists, hpuxci sets default attributes for the device. The code that does this does not null-terminate the string passed to atoi() which results in a segfault (segmentation fault). The fix for this will terminate the string correctly. Auto-Port Aggregation Will Not Work on rp7410 Systems The igelan driver for core rp2710 cards does not support Auto-Port Aggregation (APA). What To Do To fix this problem install patch PHNE_25833 (or any patch that supersedes it). Appendix B 165 Known Problems and Troubleshooting Problems Configuring HP-UX 11i v1 EISA Cards Not Supported on 64-bit OS EISA I/O drivers for TermIO, FDDI, 100BT and Token Ring cards are supported on HP-UX 32-bit OS, but not 64-bit OS. You will not see an error or warning message stating that these EISA products will not work after installing or updating to 64-bit OS. 100BT HSC-FX Cards Do Not Work on HP-UX 11i v1 The100BT HSC-FX cards, J3514A#002 and J3516A#002, do not work under 11i. The card is claimed, but the link does not come up. This card is supported on K-Class, D-Class and A-180 systems. If you are not sure whether or not the card is installed in your system, use the appropriate command: ioscan -kfClan | grep J3514A#002 (on K-Class) ioscan -kfClan | grep J3516A#002 (on A-180 or D-Class) If the card is installed, you will see the hardware path, interface number and other details displayed on the screen. To fix the problem, either install patch PHNE_22727 or replace the HSC-FX card with an HSC-TX card, J3514A#001 (K-class) or J3516A#001 (A-180 and D-Class). If you replace the card, you will also need an FX-to-TX converter. The converter is not an HP product but has been qualified for use with HP cards; it is made by Transition Networks, part number C/E-100BTX-FX-04(SC). SCSI PCI Restrictions for OLA/R Online addition and replacement (OLA/R) of PCI HBAs is available in HP-UX 11i v1 on the HP 9000 L-Class, N-Class, and Superdome systems. This feature allows you to add or replace a failed HBA without having to reboot the system. Some restrictions in the ability to perform online addition (OLA) and/or online replacement (OLR) apply with these SCSI HBAs: • • • • • 166 A4800A A5149A A5150A A5159A A5838A Appendix B Known Problems and Troubleshooting Problems Configuring HP-UX 11i v1 You can find more information about SCSI HBA OLA/R restrictions by going to the HP-IT Resource Center (ITRC), at the following URL: http://itrc.hp.com 1. Go to the area for knowledge trees 2. Under "Hardware" select Networks 3. Select mass storage connectivity 4. Select scsi hba’s 5. Select technical support This takes you to a page titled "scsi hba’s." (You might want to bookmark this page, for future reference.) 6. Select the ola/r support link in the list on the left side of the page; this takes you to the SCSI HBA OLA/R restrictions. SCSI PCI HBA Documentation Correction An error exists in the current manual for each of following SCSI PCI Host Bus Adapters (HBAs): A4800A, A5149A, A5150A, and A5159A The content for the “Setting the SCSI IDs” section of the “Installing the Adapter” chapter is not correct. The correct content for the “Setting the SCSI IDs” section is as follows: You must assign the SCSI host bus adapter and each SCSI device a separate SCSI ID (0 through 15 for a 16-bit SCSI bus). The device's priority on the SCSI bus is determined by the device's SCSI ID. The order of SCSI ID priorities (from highest to lowest) is 7, 6, 5, 4, 3, 2, 1, 0, 15, 14, 13, 12, 11, 10, 9, and 8. A device with SCSI ID 7 has the highest priority, and one with SCSI ID 8 has the lowest. When you are assigning SCSI IDs, we recommend you give the SCSI host bus adapter higher priority than the other SCSI devices on the bus. SCSI ID 7 is the preset SCSI ID for your HP SCSI host bus adapter (giving it the highest priority on the SCSI bus). Set each of the other SCSI devices on the bus to one of the remaining SCSI ID's. For a multi-initiator (High Availability [HA]) configuration-where multiple SCSI host bus adapters are connected to the same SCSI bus-the SCSI host bus adapter that carries the most traffic should be assigned a SCSI ID of 7 (giving it the highest priority), then you Appendix B 167 Known Problems and Troubleshooting Problems Configuring HP-UX 11i v1 must change the SCSI ID of each of the remaining SCSI host bus adapter's on the bus from the preset setting (7), to the next highest priority remaining SCSI IDs (e.g. 6, 5, 4... and so on). If you plan to boot your system from a hard disk drive on the SCSI bus, you should assign that drive the next highest priority unassigned SCSI ID. If there is only one SCSI host bus adapter (SCSI ID = 7), the hard disk drive would be assigned a SCSI ID of 6. If there are multiple SCSI host bus adapters, the hard disk drive would be assigned the next highest priority SCSI ID available after all of the SCSI host bus adapters have been assigned higher priority SCSI IDs. The peripheral device SCSI IDs are usually set with jumpers or a switch on the peripheral. Refer to the peripheral manufacturer's instructions to determine the ID of each device and how to change it. You must have no duplication of SCSI IDs on a SCSI bus-the system will hang or crash if duplicate SCSI IDs are on the bus. See the “Checking SCSI Bus Compatibility” section of the Service and User Guide for details on conforming and changing SCSI IDs. The following manuals are affected: • HP A4800A PCI FWD SCSI Host Bus Adapter Service and User Guide (A3725-96031, E0201), page 30 • HP A5149A PCI Ultra2 SCSI Host Bus Adapter Service and User Guide (A5149-96003, E0201), page 31 • HP A5150A PCI Dual Port Ultra2 SCSI Host Bus Adapter Service and User Guide (A5150-96002, E0201), page 35 • HP A5159A PCI Dual Port FWD SCSI Host Bus Adapter Service and User Guide (A5159-96002), page 31 168 Appendix B Known Problems and Troubleshooting Problems Configuring HP-UX 11i v1 HP-UX Apache-based Web Server Requires LD Patch to Start and Stop IMPORTANT Due to an ld defect, you may encounter problems starting and stopping HP-UX Apache-based Web Server (hpuxwsApache). At the time of this writing, HP is unable to include a patch. To fix this problem, follow the steps below: To verify and install the required version of ld and libdld for the HP-UX Apache-based Web Server: Step 1. Verify that you are using ld and libdld version B.11.32 or higher. To determine the version, enter the following command: ld -V Step 2. If the version number is less than B.11.32, install Patch PHSS_26560. See “HP-UX Patching and Patch Management” on page 117 for more information on patches. Step 3. As root, manually start HP Apache using the following command: /opt/hpws/apache/bin/apachectl1 start Additional Documentation For detailed configuration and installation instructions, see the following HP Apache documentation in the paths listed below (or at http://machinename/hp_docs/apache/document after the web server is started): HP Apache Admin Guide: /opt/hpws/hp_docs/apache/apache.admin.guide HP Apache Release Notes: /opt/hpws/hp_docs/apache/apache.release.notes Appendix B 169 Known Problems and Troubleshooting Problems with Large Systems Problems with Large Systems After a system is cold-installed, you may wish to add all the file systems that existed under the previous installation, either manually or using sam. However, for a large number of file systems (for example, over a hundred), some tables in the kernel may be too small to allow correct booting. This is because the newly-installed kernel contains default values for kernel tables sizes, and does not allow for special configurations made to the previous kernel. For example, the first boot after adding the file systems may result in error messages displayed to the console, such as: inode: table is full proc: table is full file: table is full The boot may fail in other ways. For example, you may have to repair the file system manually: • The kernel may need to be re-configured before booting. The following settings should allow the kernel to be booted, but may not be optimal for performance: ninode = 2048 (default is 476) nproc = 1024 (default is 276) nfile = 2048 (default is 790) • Alternatively, you may re-configure the kernel using one of these methods: — Select an appropriate bundle of sam-tuned parameters from sam’s kernel configuration Actions menu. — Raise maxusers to a large value, such as 200. Determine the correct configuration for your system. 170 Appendix B Known Problems and Troubleshooting Un-installing HP-UX 11i v1 Un-installing HP-UX 11i v1 If you cannot resolve problems after installing or updating to HP-UX 11i v1, you may wish to un-install 11i. The process depends upon the install or update process you followed: • Assuming that you have made a make_tape_recovery or make_net_recovery tape using Ignite-UX, boot the system from that media to return the OS and any archived applications to the previous release. This is covered in the Ignite-UX Administration Guide, available on the HP-UX 11i v1 Instant Information CD and on this web page: http://docs.hp.com/ If you don’t use Ignite-UX or do not have a current make_tape_recovery tape, read on.... • If your applications and data are on a separate disk from the OS, cold-install the previous OS over 11i. This ensures a clean OS installation, removing all previous upgrade and patch information. • If applications and/or data are on the same volume with the OS, boot from the previously-saved system recovery tape to return to a previous OS. These "expert recovery" processes are in the Ignite-UX Administration Guide. To determine what applications are on the system and where they are located, use swlist. If you only need to remove applications or patches from the system, use swremove. See the Software Distributor Administration Guide for details. Appendix B 171 Known Problems and Troubleshooting Re-installing SD Re-installing SD If your system needs re-updating and/or you find that Software Distributor (SD) needs updating, you can re-install SD. To update SD, you must first load the install-sd utility onto your system, then use install-sd to get the new version of SD. Step 1. The install-sd utility is in the catalog/SW-DIST/pfiles directory on the HP-UX 11i v1 OE CD1. If install-sd is not in /var/tmp, load it. For example, to load install-sd from a local CD mounted at /cdrom, enter: cp /cdrom/catalog/SW-DIST/pfiles/install-sd /var/tmp The install-sd command uses the /var/tmp directory by default and needs at least 2MB of free space. Step 2. Copy the swagent.Z file from the CD: cp /cdrom/catalog/SW-DIST/pfiles/swagent.Z /var/tmp Step 3. Make install-sd executable: chmod +x /var/tmp/install-sd Step 4. Run install-sd to install the SW-DIST product onto your system: /var/tmp/install-sd -s /sd_cdrom For more about the install-sd command, see Appendix C of the Software Distributor Administration Guide, available on the Instant Information CD and on this web page: http://docs.hp.com Help on using install-sd is also on the Software Distributor web site: http://www.hp.com/products/SD_AT_HP 172 Appendix B Known Problems and Troubleshooting Recovering a Corrupt System Recovering a Corrupt System If your system will not boot at the login prompt, or the system boots but critical files are corrupt, adversely affecting system performance, it may be useful to restore system elements from the HP-UX Install/Update/ Recovery media. If there are little or no user applications or data on the system, the best recovery method is usually to cold-install the OS, as explained in Chapter 5, “Cold-Installing HP-UX 11i v1,” on page 75. This will erase all data and software on the root disk. If you wish try to preserve user data or applications on the root disk, however, procedures are available to rebuild the OS. These “expert recovery” procedures are explained in the Ignite-UX Administration Guide. This guide is available on the HP-UX Instant Information CD (which you can view via an HP-UX or Windows/NT system), and also on this web page: http://docs.hp.com/hpux/os/11i/oe/ Patch Required for fbackup (1M) and frecover (1M) on SDLT320, SDLT220, and DLTvs80 Tape Drives Patch PHCO_28998 is now available from the ITRC. PHCO_28998 fixes defects with the fbackup and frecover commands to work with the latest SDLT320, SDLT220 and DLTvs80 tape drives. To download the patch: Step 1. Go to the following URL: http://www.itresourcecenter.hp.com Step 2. Log in with your IT Resource Center user ID and password Step 3. Under maintenance and support (hp products), select find individual patches and firmware (under the patching heading), then enter the desired patch number NOTE You can also download a patch using anonymous ftp on the ftp://ftp.itrc.hp.com server. Appendix B 173 Known Problems and Troubleshooting Verifying and Adding Diagnostic Drivers Verifying and Adding Diagnostic Drivers HP-UX 11i v1 automatically installs Support Tools on all systems to provide required hardware support. These tools, contained in the OnlineDiag bundle, give you a complete solution for verifying, troubleshooting, and monitoring HP system hardware. This includes CPUs, memory, interface cards, mass storage devices, and other devices. To see if the diagnostic drivers are present and to use sam to install them if they are not: Step 1. cd /stand Step 2. Run the what command on the kernel file from which the system is booted, usually vmunix: /usr/bin/what vmunix | grep diag If the diagnostic drivers are there, the output contains diag1, and diag2 on workstations and diag0, diag1, and diag2 on servers. If not, load the drivers as follows: Step 3. As root, run sam: /usr/sbin/sam Step 4. From the sam menus, select Kernel Configuration/Subsystems, then select the DIAGNOSTICS subsystem. Pull down the Actions menu and select Add Subsystem to Kernel. The third column of the matrix, Pending, should now show In for the DIAGNOSTICS subsystem. Step 5. Select Actions -> Process New Kernel. Confirm that you want to reboot the system when prompted. Help with using Support Tool Manager and the other diagnostics is in the Support Plus: Diagnostics User’s Guide, available on the Support Plus CD in: /cdrom/DIAGNOSTICS/DIAG_USR.PDF 174 Appendix B Known Problems and Troubleshooting Problems Affecting Non-C Locales Problems Affecting Non-C Locales Difference Between English and Japanese HP-UX STK The English and Japanese versions of the STK bundled with HP-UX 11i v1 may contain differing documentation (the STK tools are identical for both languages). To verify that you have the latest Japanese documentation set, view these web sites: http://devresource.hp.com/STK_ja_JP.SJIS Warning When Updating to Non-C locales Warning! One or more of your selected locales are not available. Please invoke the commands "locale" and "locale -a" to verify your selections and the available locales. Continuing processing using the "C" locale. Ignore this message which appears when updating from 10.20 in every locale except C. The local environment, such as Japanese, is temporarily disabled during the update session. Appendix B 175 Known Problems and Troubleshooting Problems Affecting Non-C Locales 176 Appendix B HP-UX 11i v1 Software Bundles C HP-UX 11i v1 Software Bundles This appendix describes the software bundles included in the HP-UX 11i v1 media contents. What You Will Find in This Appendix Appendix C • “Core Software” on page 178 • “Always Installed Software (Stand-Alone)” on page 179 • “Always-Installed Software (OE)” on page 180 • “Always-Installed Network and Mass Storage Drivers” on page 183 • “Default-Installed Software” on page 184 • “Selectable Software” on page 186 • “Selectable Network Drivers” on page 187 177 HP-UX 11i v1 Software Bundles Core Software Core Software The core software installed for all Operating Environments comprise the following software bundles: Table C-1 Bundle Name Core Software Description HPUXBase32 or HPUXBase64 HP-UX 11i v1 Base OS installation, either 32- or 64-bit HPUXBaseAux Additional OS software including SD, SCR EMS Framework, Judy Libraries, Update-UX, ObAM5, and Partition Manager 178 Appendix C HP-UX 11i v1 Software Bundles Always Installed Software (Stand-Alone) Always Installed Software (Stand-Alone) The software listed in Table C-2 is always installed with the HP-UX 11i v1 operating system. Table C-2 Always Installed Software (Stand-Alone) Bundle Name Description OnlineDiag HP-UX 11i v1 Support Tools HWEnable11i Support for new hardware BUNDLE11i Required OS Patches FEATURE11-11 Feature Enablement Bundle - includes required patches for the following bundles: Base-VXVM Appendix C Base-VXVM Base VxVM (v3.5) B9073BA Instant Capacity on Demand (iCOD) OpenSSL OpenSSL Npar nPartition Provider B8465BA WBEM Services 179 HP-UX 11i v1 Software Bundles Always-Installed Software (OE) Always-Installed Software (OE) The software listed in Table C-3 is installed by Operating Environment (OE). The Operating Environments are represented as follows: FOE Foundation Operating Environment EOE Enterprise Operating Environment MCOE Mission Critical Operating Environment MTOE Minimal Technical Operating Environment TCOE Technical Computing Operating Environment For the latest version information, refer to the Read Before Installing or Updating to HP-UX 11i v1 DVD booklet. Table C-3 Always-Installed Software by Operating Environment Bundle / Description Foundation Enterprise Mission Critical TCOE MTOE B8324BA 3 Cluster Object Manager B5736DA EMS HA Monitors 3 3 B5139EA Enterprise Cluster Master (ECM) Toolkit 3 T1868AA HP 3D Technology for Java 2 Standard Edition version 1.3 180 3 Appendix C HP-UX 11i v1 Software Bundles Always-Installed Software (OE) Table C-3 Always-Installed Software by Operating Environment Bundle / Description Foundation Enterprise Mission Critical TCOE MTOE T1869AA 3 HP 3D Technology API for Java 1.4 B8724AA HP CIFS/9000 Client B8725AA HP CIFS/9000 Server 3 3 3 3 3 3 3 3 B6061AA 3 HP MLIB Math Software Library B6060BA 3 HP Message-Passing Interface (MPI) B3929DA HP OnlineJFS 3.3 3 3 3 3 B3835DA HP Process Resource Manager T1905BA HP Serviceguard 3 B5140BA HP Serviceguard NFS Toolkit 3 B8843CA HP-UX Workload Manager Appendix C 3 181 HP-UX 11i v1 Software Bundles Always-Installed Software (OE) Table C-3 Always-Installed Software by Operating Environment Bundle / Description Foundation Enterprise Mission Critical TCOE MTOE 3 3 T1302AA 3 HP-UX Workload Manager Toolkit B2491BA MirrorDisk/UX 3 3 3 3 MySQL MySQL open-source database 3 B6268AA OpenGL 3D Graphics DK and RTE B3701AA 3 3 3 3 3 3 3 3 OV GlancePlus Pak B7697BA PRM Libraries J5849AA PAM Kerberos 3 TechSysConf Technical System Configuration B7580AA Visualize Conference 182 3 3 3 3 Appendix C HP-UX 11i v1 Software Bundles Always-Installed Network and Mass Storage Drivers Always-Installed Network and Mass Storage Drivers You can find the information that was formerly contained in this section in the HP-UX 11i v1 Release Notes. It is available at the HP Technical Documentation Web site: http://docs.hp.com/hpux/os/11iv1/index.html The HP 9000 and HP Integrity Server Connectivity Web site also provides more driver information: http://www.hp.com/products1/serverconnectivity/index.html Appendix C 183 HP-UX 11i v1 Software Bundles Default-Installed Software Default-Installed Software The software bundles listed in Table C-4 are installed on all Operating Environments by default. You can deselect any of these bundles before you install or update your system. Table C-4 Default-Installed Software Bundle Name Description B6848BA Ximian GNOME 1.4 GTK+ Libraries ISEEPlatform Instant Support Enterprise Edition (ISEE) MOZILLA Mozilla Application Suite MOZILLAsrc Mozilla Source Distribution NParCmds Enhanced nPartition Commands B8339BA Service Control Manager ParMgr Partition Manager perl Perl Programming Language HP-UX Web Server Suite 1 hpuxwsApache HP-UX Apache-based Web Server hpuxwsTomcat HP-UX Tomcat-based Servlet Engine hpuxwsWebmin HP-UX Webmin-based Admin hpuxwsXml HP-UX XML Web Server Tools Java Bundles 184 T1455AA Java 2 Standard Edition Runtime Plugin for Netscape and Mozilla (v1.3) B9789AA Java 2 Standard Edition Runtime Environment (v1.3) T1458AA Java 2 Standard Edition Runtime Plugin for Mozilla (v1.4) Appendix C HP-UX 11i v1 Software Bundles Default-Installed Software Table C-4 Bundle Name Default-Installed Software (Continued) Description T1457AA Java 2 Standard Edition Runtime Environment (v1.4) B9788AA Java 2 Standard Edition Software Development Kit/Runtime Environment (v1.3) T1456AA Java 2 Standard Edition Software Development Kit/Runtime Environment (v1.4) T1457AA addon Java 2 Standard Edition Runtime Environment Add-On T1456AA addon Java 2 Standard Edition Software Development Kit Add-On 1. In June 2003, HP Apache rebundled into four separate bundles as part of the HP-UX Apache Web Server Suite, and replaces the HP Apache bundle in previous releases. Appendix C 185 HP-UX 11i v1 Software Bundles Selectable Software Selectable Software The bundles listed in Table C-5 are not installed or updated by default. You must select the desired bundles prior to installing or updating your system. Table C-5 Selectable Software (All OEs) Bundle Name B5725AA Description HP-UX Installation Tools (Ignite-UX) Includes the following packages: Ignite-UX-11-23 - Ignite-UX for 11.23 Ignite-IA-11-22 - Ignite-UX for 11.22 Ignite-UX-11-00 - Ignite-UX for 11.0 Ignite-UX-11-11 - Ignite-UX for 11i v1 186 J5083AA HP-UX HIDS (Servers Only) B9901AA HP IPFilter JAVAOOB Java Out-of-box Utility J4269AA Netscape Directory Server (LDAP) T2351AA Pay Per Use SwPkgBuilder Software Package Builder Appendix C HP-UX 11i v1 Software Bundles Selectable Network Drivers Selectable Network Drivers You can find the information that was formerly contained in this section in the HP-UX 11i v1 Release Notes. It is available at the HP Technical Documentation Web site: http://docs.hp.com/hpux/os/11iv1/index.html The HP 9000 and HP Integrity Server Connectivity Web site also provides more driver information: http://www.hp.com/products1/serverconnectivity/index.html Appendix C 187 HP-UX 11i v1 Software Bundles Selectable Network Drivers 188 Appendix C Configuring Built-In PCI Networking D Configuring Built-In PCI Networking This appendix describes configuring built-in (or core) PCI networking cards in HP workstations and servers. Appendix D 189 Configuring Built-In PCI Networking 1000Base-T (Gigabit Ethernet) 1000Base-T (Gigabit Ethernet) These instructions apply to the 1000Base-T (Gigabit Ethernet) product. They assume that the card has been factory installed and the software already loaded on your disk. Step 1. Log in as root and verify that the card and its hardware path are displayed by executing the command: ioscan. Step 2. Run the System Administration Manager: sam. Step 3. Double click Networking and Communications. Step 4. Double click Network Interface Cards. Step 5. Highlight the Gigabit Ethernet card and choose Configure from the Actions menu. Step 6. Fill in the form according to the instructions. Step 7. Click on the OK button to activate the card and then select exit from the “File” menu until you exit SAM. Optional Step: Configure Jumbo Frame Size Jumbo frames have an mtu_size of 9000 bytes. If using Jumbo Ethernet frames, ensure that all end stations on a given LAN (that is, no routers or layer 3 switches in between) have the same MTU setting. However switch ports in the LAN can have any MTU setting greater than or equal to the end station MTU. 1. Obtain the PPA number of the card by executing: lanscan 2. Choose one of two configuration methods that will permanently save your configuration. You can either: • 190 use the GUI-based system admin manager (SAM). To use SAM, type sam at the HP-UX system prompt; then double-click Networking and Communications, and then Advanced Configuration--see the Ethernet Support Guide for details, and then do the steps for verifying the MTU size; or Appendix D Configuring Built-In PCI Networking 1000Base-T (Gigabit Ethernet) • edit the configuration file in /etc/rc.config.d/using an editor such as “vi.” Depending on your driver, the filename can be either hpgelanconf, hpigelanconf, or hpietherconf. Set the mtusize by editing either HP_GELAN_MTU[0]=mtusize, HP_IGELAN_MTU[0]=mtusize, or HP_IETHER_MTU[0]=mtusize, and insert the proper interface name: HP_GELAN_INTERFACE_NAME, HP_IGELAN_INTERFACE_NAME, or HP_IETHER_INTERFACE_NAME. When the system reboots, the interface will be configured for jumbo frame operation. 3. Verify MTU change by executing: netstat -rn. If MTU has not changed, execute the following commands: ifconfig lan PPA_number unplumb ifconfig lan PPA_number ip_address netmask netmask up 4. To check (or verify) the current Ethernet frame size, execute: lanadmin -m PPA_number Alternative way to temporarily configure jumbo frame size: Execute: lanadmin -M mtu_size PPA_number. The PPA number is the one we obtained from the output of lanscan. For jumbo frames set the mtu_size to 9000 (bytes). Note: using lanadmin will not preserve your settings across reboots. Appendix D 191 Configuring Built-In PCI Networking Optional: Troubleshooting a Fast Ethernet Migration to HP-UX 11i Optional: Troubleshooting a Fast Ethernet Migration to HP-UX 11i The following information is applicable only if your Fast Ethernet update to HP-UX 11i fails. In HP-UX 11i, the drivers for PCI and HSC-based Fast Ethernet networking are consolidated into one driver called btlan, which is pre-installed as part of the kernel. The configuration files used by these networking drivers in HP-UX 10.20 and 11.0—hpbtlanconf (btlan), hpbase100conf (btlan3), hpgsc100conf (btlan4), hppci100conf (btlan5), and hpsppci100conf (btlan6), which are in the /etc/rc.config.d directory, are merged into one file. IMPORTANT The configuration files used by the PCI and HSC-based Fast Ethernet networking drivers are automatically updated as part of the process of migrating to HP-UX 11i. If the update process fails, the PCI and HSC pre-update configuration files have to be merged manually as explained further in the following paragraphs. How the Automatic Merge Works Using the BTLAN.100 Script During an update, a configuration script called BTLAN.100, automatically merges HSC and PCI pre-11i Fast Ethernet configuration files into one file called hpbtlanconf. Once the BTLAN.100 script creates the merged configuration file, it is placed temporarily in the /var/adm/sw/save_custom/UNIFIED_MER directory, and the original configuration files are saved with the extension .obsolete. During the consolidated btlan driver installation, the merged configuration file is then moved to the /etc/rc.config.d directory as hpbtlanconf. Note that the BTLAN.100 script will only merge the driver-specific configuration files if the corresponding hardware is present on the system, and if the files have at least one LAN interface configured. (For 192 Appendix D Configuring Built-In PCI Networking Optional: Troubleshooting a Fast Ethernet Migration to HP-UX 11i example, if the system had the HSC-based Fast Ethernet networking driver [btlan4] and corresponding hardware [HSC cards], then the hpgsc100conf configuration file should have at least one card configured in it.) Optional: Manual Merging If the update process is abandoned because of preupdate script failures (other than syntax errors in configuration files or a duplicate LAN interface error), then the configuration files have to be merged manually. Once this has been done, you can then continue the update process. (Once the update process is restarted, answer NO (N) at the prompt, Do you want to proceed in merging the configuration files into one? [Y|N].) Manual Merging Procedure 1. Find out which of the five configuration files listed below exists in the /etc/rc.config.d directory. • • • • • hpbtlanconf (btlan) hpbase100conf (btlan3) hpgsc100conf (btlan4) hppci100conf (btlan5) hpsppci100conf (btlan6) 2. For each of the files found in Step 1, use the command ioscan -kfC lan to find out if corresponding hardware is present. Driver Name: File Name a. b. c. d. e. btlan -- hpbtlanconf btlan3 -- hpbase100conf btlan4 -- hpgsc100conf btlan5 -- hppci100conf btlan6 -- hpsppci100conf If hardware is present, check to see if any LAN interface is configured. For example, the configuration for hpbtlanconf (btlan) would show as follows: HP_BTLAN_INTERFACE_NAME[0]=lan1 HP_BTLAN_STATION_ADDRESS[0]=0x080009C4686E HP_BTLAN_SPEED[0]=100HD Appendix D 193 Configuring Built-In PCI Networking Optional: Troubleshooting a Fast Ethernet Migration to HP-UX 11i 3. Create the file hpbtlanconf.merge in the directory /etc/rc.config.d as shown below: ##################################################################### (#) hpbtlanconf # hpbtlanconf: contains config values for HP PCI/HSC 100Base-T interfaces # # HP_BTLAN_INTERFACE_NAME Name of interface (lan0, lan1, . . .) # HP_BTLAN_STATION_ADDRESS Station address of interface # HP_BTLAN_SPEED Speed and duplex mode # # The interface name, major number, card instance and ppa may be # obtained from the lanscan (1m) command. # The station address and speed are set through the lanadmin command. ##################################################################### HP_BTLAN_INTERFACE_NAME[0]= HP_BTLAN_STATION_ADDRESS[0]= HP_BTLAN_SPEED[0]= ##################################################################### # The HP_BTLAN_INIT_ARGS are reserved by HP. they are NOT user changeable. ##################################################################### HP_BTLAN_INIT_ARGS="HP_BTLAN_STATION ADDRESS HP_BTLAN_SPEED" # End of hpbtlanconf configuration file 4. As described in steps a, b, and c below, merge every LAN interface (as shown to be configured in Step 2) into the file hpbtlanconf in the /var/adm/sw/save_custom/UNIFIED_MER directory. a. First, note that a set of three parameters is required for each LAN interface: • • • HP_BTLAN_INTERFACE_NAME, HP_BTLAN_STATION_ADDRESS and HP_BTLAN_SPEED. b. Second, note that the index value used for the set of three parameters should be unique for each interface. For example: HP_BTLAN_INTERFACE_NAME[0]=lan1 HP_BTLAN_STATION_ADDRESS[0]=0x080009C4686E HP_BTLAN_SPEED[0]=100HD HP_BTLAN_INTERFACE_NAME[1]=lan2 HP_BTLAN_STATION_ADDRESS[1]=0x080009C4B23C HP_BTLAN_SPEED[1]=FULL 194 Appendix D Configuring Built-In PCI Networking Optional: Troubleshooting a Fast Ethernet Migration to HP-UX 11i c. Finally, merge all LAN interfaces by creating a set of three parameters with a unique index for each: • Copy the value of the interface name into the parameter HP_BTLAN_INTERFACE_NAME. • Copy the value of the station address into the parameter HP_BTLAN_STATION_ADDRESS. • If the SPEED parameter exists, and if its value (lowercase or uppercase) is 100FD or 100HD, 10FD or 10HD or auto_on, copy the value into the HP_BTLAN_SPEED parameter. However, if the SPEED parameter does not exist, and the DUPLEX parameter has been set and its value (lowercase or uppercase) is FULL or HALF, copy the value to HP_BTLAN_SPEED parameter. If neither the SPEED nor DUPLEX parameter values have not been set, do not put any value for the HP_BTLAN_SPEED parameter. 5. If the hpbtlanconf configuration file already exists (as /etc/rc.config.d/hpbtlanconf), copy it to /etc/rc.config.d/hplanconf.obsolete. 6. Move the file hpbtlanconf.merge to hpbtlanconf by using the command mv -f /etc/rc.config.d/hpbtlanconf.merge /etc/rc.config.d/hpbtlanconf 7. Restart the update process. Answer NO (N) at the prompt, Do you want to proceed in merging the configuration file into one? [Y|N]. Appendix D 195 Configuring Built-In PCI Networking Optional: Troubleshooting a Fast Ethernet Migration to HP-UX 11i 196 Appendix D Controlling Memory Utilization of VxFS 3.5 on HP-UX 11i v1 E Controlling Memory Utilization of VxFS 3.5 on HP-UX 11i v1 This appendix discusses the effect of two VxFS tunables vx_ninode and vxfs_bc_bufhwm, on system memory consumption and provides guidelines on setting them for machines with relatively low RAM. What You Will Find in This Appendix: • “Introduction” on page 198 • “Controlling the inode Cache” on page 199 • “Controlling the Buffer Cache” on page 200 • “Conclusion” on page 201 Appendix E 197 Controlling Memory Utilization of VxFS 3.5 on HP-UX 11i v1 Introduction Introduction VxFS 3.5 resorts to caching objects in memory as a way to improve performance. Most of the memory consumed by VxFS is used to cache inodes (in the inode cache) and metadata (in the buffer cache). The sizes of these caches and the behavior of VxFS are controlled by a set a tunables. The performance of VxFS can be tailored to meet a variety of usage scenarios taking into account variations in machine configurations via the use of these tunables. The default settings of these tunables are meant to provide good performance for typical deployment configurations. However, these default values can result in the VxFS driver consuming more memory, especially when the file systems are stressed (under heavy file system load). For machines low on RAM, these tunables may need to be manually turned down depending on the expected use of the machine and the performance required of the file system. VxFS 3.5 exposes two global tunables, vx_ninode and vxfs_bc_bufhwm, that control the size of the inode cache and buffer cache respectively and thereby affect system memory consumption by the file system driver. This appendix discusses when and why the sizes of the inode and buffer caches will need to be tuned down from their default values on certain configurations. The following sections describe these tunables in detail as well as the effects of changing their default values. 198 Appendix E Controlling Memory Utilization of VxFS 3.5 on HP-UX 11i v1 Controlling the inode Cache Controlling the inode Cache As a matter of course, VxFS file systems allocate and free up inodes as required by the load on the file system. VxFS caches these inodes for better performance (faster lookups). In general, larger inode caches help file systems perform better for file/web server loads. The global (static) tunable vx_ninode, represents the maximum possible size of the VxFS inode cache. Normally, the size of the inode cache is decided (auto-tuned) at boot time by VxFS depending on the amount of physical memory in the machine, provided that the value of vx_ninode is set to zero (default). However, system low on RAM (typically less than or equal to 1GB/CPU may not require a large inode cache if file systems are not exposed to file/web server loads, or file system performance is not critical. It is recommended that the value of vx_ninode be set to more than that of nfile, an HP-UX tunable that represents the maximum number of file descriptors. Appendix E 199 Controlling Memory Utilization of VxFS 3.5 on HP-UX 11i v1 Controlling the Buffer Cache Controlling the Buffer Cache VxFS 3.5 implements a private buffer cache used exclusively for metadata. The allocations made for this buffer cache are not static but grow and shrink during system usage depending on the load on the file system. The global (static) tunable, vxfs_bc_bufhwm, represents the maximum possible size of the VxFS buffer cache. The maximum size of the metadata buffer cache is decided (auto-tuned) at boot time based on system memory size, provided that the value of vxfs_bc_bufhwm is set to zero (default). As with the tunable vx_ninode, a large metadata buffer cache can help improve file system performance especially during metadata-intensive loads (stat, create, remove, link, lookup operations). However, systems low on RAM (having typically 1GB/CPU or less) may not need a large metadata buffer cache if file system load is not metadata-intensive or performance is not critical. In such circumstances, the value of vxfs_bc_bufhwm can be manually tuned down, subject to a minimum of 6144 (6MB). 200 Appendix E Controlling Memory Utilization of VxFS 3.5 on HP-UX 11i v1 Conclusion Conclusion VxFS uses in-memory caches for objects that results in improved file system performance. The cache sizes are controlled by tunables that are auto-tuned at boot time by the driver. For situations where the auto-tuned values are not optimal, users are provided with the ability to set these tunables. Appendix E 201 Controlling Memory Utilization of VxFS 3.5 on HP-UX 11i v1 Conclusion 202 Appendix E Index Symbols /etc, 64 /etc/passwd, 87 /home, 87, 88 /local, 88 /opt, 64, 88 /usr, 88 /usr/local/, 64 /usr/sbin, 101 /var, 84 Numerics 100BT HSC-FT card not supported on 11i, 166 64-bit OS considerations, 57 update example, 108 updating to, 57 A adding an OE, 106 additional software guided installation, 83 administration URL, 23 advanced installation, 82 alternative install methods, 77, 94 analyzing log files, 150 Apache updating an existing version, 50, 92 Apache-based Web Server, 21 applications, 113 configuring after update, 111 Applications DVD, 26 autoboot halting, 80, 126 aways-installed software bundles, 180 B backup, 64, 65, 71, 122 before you begin installing, 76 updating, 92 boot device types, 80 boot information newer series 800, 129, 130 older series 700, 128 older series 800, 130 Superdome, 56 boot Main Menu, 80 buffer cache VxFS, 200 bundles always-installed software, 179, 180 core software, 178 default-installed software, 184 selectable software, 186 C cache buffer, 200 inode, 199 CDE (Common Desktop Environment), 35, 64, 87 choosing file system, 82 cleaning log files, 64, 65, 68 codewords, 72 cold-install, 32, 53, 54 alternative methods, 53 compared to update, 54 considerations, 56 instant ignition, 49 deciding an installation method, 54 definition, 50 flowchart, 78 kernel build fails, 138 Netscape Directory Server, 93 paths, 50 procedure, 79 troubleshooting, 138 typical problems, 138 vs. update, 53 commands fbackup, 69 frecover, 69 ioscan, 99, 100 make_net_recovery, 70, 171 make_tape_recovery, 71, 171 mk_kernel, 67 mount, 99, 100 sam, 99 swcopy, 100 swinstall, 94, 101 swlist, 67 203 Index swremove, 107 uname, 17, 45 update-ux, 91, 98, 100, 101, 102, 105 configuration, 64, 85 OE Applications, 111 configuring HP-UX 11i problems, 163 considerations 64-bit OS, 57 bundle, 58 cold-install, 56 instant ignition, 49 Netscape Directory Server, 93 update, 57 contents media kit, 26, 177 core software bundles, 178 corrupt system recovering, 173 creating a depot, 99 creating new root directory, 87 D deciding an installation method cold-install, 54 update, 55 default-installed software, 184 depots creating, 99 diagnostics not installed, 174 online, 60, 84 verifying and adding, 174 directories, 87 disk space, 33 disk space requirements, 33 partitions, 33 usage errors, 156 disk volume, 83 downgrading OE, 107 drivers, 43, 85 selectable, 187 updating network, 43 DVDs HP-UX 11i v1, 26 HP-UX 11i v1 Application Release, 26 204 Internet Express, 26 E Enterprise OE, 105 ergonomics, 22 error codes with update-ux, 97 error messages, 153 error recovery, update-ux, 153 errors disk space usage, 156 disk-space usage, 156 I/O, 154 multiple I/O, 154 post-update verify, 156 root vol. locked, 157 swinstall, 156 update/install, 153 examples adding an OE, 106 downgrading OE, 107 update from network depot, 107 update selectable software, 110 update to 64-bit OS, 108 update using interactive software selection, 108 update using match_target, 109 update-ux, 104 updating 11i v1 OE, 105 upgrading OE, 106 F factory ignited, 49, 77, 94 Fast Boot, enabling, 80 feedback, 21 file partitions, 34 file sizes, 33 file system, 82 firmware recommendations, applying patches, downloading updates, 44 floppy drives update problems, 165 flowchart cold-install process, 78 update process, 95 Index FOE, 105 forums system administration, 23 Foundation OE, 105 frecover command, 88 G General Release patch bundle, 58 GOLDAPPS11i patch bundle, 58 GOLDBASE11i patch bundle, 58 golden images, 77, 94 guided installation, 82 H halting autoboot, 80, 126 hardware failures, 60 hints disk space, 33 home directory, 87 how to apply firmware patches, 44 cold-install, 79 update, 98 update using interactive software selection, 108 HP-UX 11i 100BT HSC-FT card supported, 166 64-bit OS considerations, 57 configuration problems, 163 OLA/R support, 166 patch bundles, 58 un-installing, 171 update (no OE), 106 update procedure, 102 update to 64-bit OS, 108 updating, 91, 98 HP-UX 11i v1 Applications DVD, 26 cold-install deciding when, 54 considerations, 56 deciding which method, 53 DVDs, 26 existing system, 49 Installation and Update Guide, 26 Instant Information CD, 26 Internet Express DVD, 26 migrating from older releases, 50 rebuilding kernel before updating, 67 Release Notes, 26 update deciding when, 55 HWEnable11i patch bundle, 58 I I/O errors, 154 identifying model, 45 identifying OE, 45 identifying OS, 45 identifying software, 45 IDS 9000, 186 Ignite-UX, 22, 53, 54, 65, 70, 71, 81, 186 VxVM, 56 install before you begin, 76 verify, 119, 120 install information, 87 install kernel autobooting (S800), 129 booting (s700), 127 stopping autoboot (S800), 129 installing, 79, 81, 82 installing from instant ignition, 49 installing OnlineDiag, 60 installing software, 114 install-sd, 172 Instant Ignition, 77, 94 installing from, 49 interactive mode updating with, 108 interactive software selection, 108 introduction, 59 ioscan, 99, 100, 114 IPFilter, 186 ITRC, 22, 23 J Java Out-of-Box, 186 JAVAOOB, 186 K kernel, 67 NTPY Parameter, 151 rebuilding, 67 L languages, 22 large systems, 170 205 Index legal notice, 2 locales problems with non-C, 175 localization, 22 locating codewords, 72 locating source media, 72 log files cleaning, 64, 65, 68 LVM, 87 M make_net_recovery, 65, 70 make_tape_recovery, 71 match_target, 109 using, 109 MCOE, 105 media, 72, 79 contents media kit, 177 kit, 26 migration paths deciding a method, 53 from previous HP-UX releases, 50 mk_kernel, 67 model, 45 mount, 99, 100 MTOE, 35, 105 multiple I/O errors, 154 N Netscape Directory Server, 186 considerations, 93 updating, 93 network depot, 99 update example, 107 network drivers, 85 selectable, 187 networking updating drivers, 43 new root, 87 NTPY, 151 O OEs adding an OE, 106 bundle names, 105 configuring applications, 111 downgrading, 107 206 Enterprise OE, 105 Foundation OE, 105 MCOE, 105 MTOE, 105 TCOE, 105 updating, 91 OLA/R support, 166 older HP-UX Releases migrating to HP-UX 11i v1, 50 OnlineDiag, 60 operating environments, 28, 29, 35, 45 adding an OE, 106 configuring applications, 111 downgrading, 107 Enterprise OE, 105 Foundation OE, 105 MCOE, 105 MTOE, 105 TCOE, 105 updating, 91, 105 upgrading, 106 optional software, 114 OS, 45 un-installing, 171 updating, 91 overview, 59 updating, 94 P parameters NTPY, 151 patch bundles available bundles, 58 GOLDAPPS11i, 58 GOLDBASE11i, 58 HWEnable11i, 58 patches, 22, 113 Pay Per Use, 186 PCI drivers, 43 planning, 33 post-installation tasks, 87 pre-installed, 49 problems configuring HP-UX 11i, 163 floppy drives, 165 non-C locales, 175 Index update, 151 process, 79 update, 94 Q Quality Pack patch bundle, 58 R Read Before Installing or Updating to HP-UX 11i v1 DVD booklet, 26 rebuild kernel, 67 rebuilding kernel, 67 record software versions, 67 recover corrupt system, 173 recovering files, 87 re-installing SD, 172 release notes, 21 required media, 79 requirements, 32 restoring /home, 88 restoring /local, 88 restoring /opt, 88 restoring /usr, 88 retrieving install information, 87 reviewing cold-install, 79 root, 83, 87 root disk, 82 root swap space, 82 root volume, 83 rootability VxVM, 56 S safety, 22 sam, 64, 99 saving configuration files, 64 SCM, 23 SCSI, 43 SD, 23 re-installing, 172 selectable network drivers, 187 software, 186 IDS 9000, 186 Ignite-UX, 186 IPFilter, 186 Java Out-of-Box, 186 Netscape Directory Server, 186 Pay Per Use, 186 software package builder, 186 selectable drivers, 43 selectable software updating, 110 selected locale not availavble, 153, 175 selecting additional software, 83 servers, 42 Servicecontrol Manager, 23 set_parms, 85 sizes file partitions, 34 software, 45 always-installed, 180 core bundles, 178 media, 177 record versions, 67 selectable, 186 updating selectable software, 110 software depots, 77, 94 Software Distributor, 23 software package builder, 186 software selection interactive mode, 108 software transition kit, 22 source media, 72 specifying swap space, 82 STK, 22 storage, 43 Superdome booting patitions, 56 installing HP-UX, 56 support, 21 Support Plus patch bundles, 58 supported systems, 42 swap space, 82 swcopy, 100 swinstall, 77, 94, 101, 114 errors, 156 swlist, 35, 67, 120 swremove, 35, 107 swverify, 120 system backup, 71 system backup, 122 system requirements, 32 T TCOE, 35, 105 tips updating, 96 207 Index trademark notices, 2 transition kit, 22 troubleshooting installs/updates, 153 large systems, 170 U uninstalling HP-UX 11i, 171 update 64-bit OS, 57 before you begin, 92 deciding an installation method, 55 error codes, 97 examples adding an OE, 106 from network depot, 107 interactive software selection, 108 selectable software, 110 to 64-bit OS, 108 upgrading OE, 106 using match_target, 109 flowchart, 95 from a network depot, 107 how to, 98 HP-UX 11i, 102 interactive mode, 108 Netscape Directory Server, 93 network drivers, 43 NPTY parameter failure, 151 operating environments, 91 OS, 91 OS without OE, 106 overview, 94 problem with floppy drives, 165 selected locale not available, 153, 175 steps create network depot, 99 installing update-ux, 100 using update-ux, 102 swcopy, 100 tips, 67, 96 clean log files, 64, 65, 68 configuration, 111 rebuild kernel, 67 record software versions, 67 208 to 64-bit OS, 57 to an 11i v1 OE, 105 troubleshooting, 153 update-ux command, 102 vs. cold-install, 55 update process flowchart, 95 monitoring, 96 recording software versions, 67 running other commands, 96 update-ux, 91, 98, 101 analyzing log files, 150 command syntax, 102 do not use -i and -x together, 108 error codes, 97 examples, 104 downgrading OE, 107 from network depot, 107 install using swinstall, 101 installing, 100 interactive software selection, 108 match_target option, 109 multiple I/O errors, 154 problems, 151 update 11i v1 OE, 105 using, 102 updating Ignite-UX, 65 usage errors disk space, 156 using make_net_recovery, 70 V VERITAS rootability, 56 VUE, 64 VxVM rootability, 56 W white papers, 21 workstations, 42 ">
/
다운로드
친절한 알림입니다. 여기에서 문서를 볼 수 있습니다. 그러나 가장 중요한 것은 AI가 이미 읽었다는 것입니다. 복잡한 내용을 간단하게 설명하고, 모든 언어로 질문에 답변하고, 가장 길거나 복잡한 문서도 빠르게 탐색할 수 있도록 도와줍니다.
광고