EMC CLARiiON Server Support software, Host Agent, Storage System Initialization Utility, Server Utility, Command Line Interface, admsnap software Installation guide
Below you will find brief information for CLARiiON Server Support, Host Agent, Storage System Initialization Utility. This guide describes how to install and remove the EMC Navisphere Host Agent, Navisphere Storage System Initialization Utility, Navisphere Server Utility, Navisphere Command Line Interface (CLI), and admsnap software on a Linux operating system. This installation guide describes how to install and remove EMC Navisphere Host Agent, Navisphere Storage System Initialization Utility, Navisphere Server Utility, Navisphere Command Line Interface (CLI), and admsnap software on a Linux operating system.
Advertisement
Advertisement
EMC CLARiiON Server Support
Products for Linux Servers
Installation Guide
P/N 300–002–041, Revision A16
March 6, 2009
This guide describes how to install and remove the EMC
®
Navisphere
®
Host Agent, Navisphere Storage System Initialization Utility, Navisphere
Server Utility, Navisphere Command Line Interface (CLI), and admsnap software on a Linux operating system.
IMPORTANT
If you have a Linux virtual machine, refer to one the following docs:
For VMware ESX Server systems – EMC CLARiiON Server Support
Products for VMware ESX Servers and Virtual Machines Installation Guide
For Windows Server 2008 with Hyper-V system– EMC CLARiiON Server
Support Products for Windows Server 2008 with Hyper Installation Guide
If you do not know if your system is a virtual machine, consult your system administrator.
Topics include:
Before you start ............................................................................. 3
About EMC Navisphere server software ......................................... 5
Finding current information ........................................................... 8
Installing and removing the Navisphere Storage System Initialization
Utility .......................................................................................... 9
Running the Navisphere Storage System Initialization Utility ........... 13
Determining whether to install the host agent or server utility
Requirements for the host agent, server utility, and CLI ................... 21
Installing or removing the Navisphere Host Agent and CLI ............. 22
Configuring the Navisphere Host Agent ........................................ 31
Using the event monitor configuration file ..................................... 33
Running the Navisphere Host Agent ............................................. 34
Installing and removing the Navisphere Server Utility .................... 37
1
Running the Navisphere Server Utility ........................................... 42
Installing and removing the Admsnap Utility ................................. 47
Running the Admsnap Utility ........................................................ 52
2
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
Before you start
❑
Read the release notes for your CX4 series, CX3 UltraScale
™ series, or CX series storage system, which are available in the Technical
Documentation and Advisories section on the
Powerlink
® website.
❑
Read the release notes for your AX4–5 series or AX150 series storage system, which are available on the Service & Support page of the storage-system support website.
The url for the storage-system support website is in the Documentation and
Support document that shipped with your storage system.
❑
Refer to the E-Lab
™
Interoperability Navigator on the
Powerlink
® website for information on supported operating system versions, including virtual machines, with a CX4 series, CX3
UltraScale
™ series, or CX series storage system.
❑
Refer to the Support Matrix link on the Install page of the storage-system support website for information on supported operating system versions, including virtual machines, with an
AX4–5 series or AX150 series storage system. For AX100 series systems, refer to the Supported Configurations in the “Technical descriptions” section of the storage-system support website.
Storage-system terminology
This document uses the following storage-system terms:
CX4 series
— to refer to CX4-120, CX4-240, CX4-480, and CX4-960 storage systems.
CX3 series
— to refer to CX3 model 10 systems, CX3 model 20 systems, CX3 model 40 systems, and CX3 model 80 storage systems.
CX series
— to refer to CX300 series, CX500 series, and CX700 storage systems.
AX4-5 series
— to refer to AX4-5SC, AX4-5SCi, AX4-5, AX4-5i storage systems.
AX150 series
— to refer to AX150SC, AX150SCi, AX150, and AX150i storage systems.
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
3
AX series
— to refer to AX150 series and AX100 series storage systems. AX100 series systems include the AX100SC, AX100SCi,
AX100, and AX100i systems.
Minimum FLARE revision required for your storage system
Table 1 lists the minimum FLARE
® version that your CLARiiON
® storage system requires and the server software that it supports.
Table 1 Minimum FLARE versions and supported software
Storage system
AX4-5 series
AX150 series
AX100 series
Minimum FLARE version
02.23.050.5.5xx
02.20.xxx.5.yyy
02.16.xxx.5.yyy
CX4–120, CX4–240, CX4–480, and CX4–960
CX3–10c
CX3 model 20 systems, CX3 model 40 systems, and CX3 model 80 systems
CX700, CX500 series, and
CX300 series
04.28.000.5.xxx
03.24.010.5.xxx
03.22.xxx.5.yyy
02.16.xxx.5.yyy
Supported server software
Storage systems with Navisphere Express
— Navisphere Storage System Initialization Utility
— Navisphere Server Utility
— Navisphere CLI
Storage systems with Navisphere Manager
— Navisphere Storage System Initialization Utility
— Navisphere Host Agent
— Navisphere Server Utility
— Admsnap Utility
— Navisphere CLI
Storage systems with Navisphere Manager
— Navisphere Storage System Initialization Utility
— Navisphere Host Agent
— Navisphere Server Utility
— Admsnap Utility
— Navisphere CLI
4
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
About EMC Navisphere server software
The EMC server-based software listed below is available on Powerlink and on the server support CD that shipped with your storage system or your upgrade kit (for upgrading AX4-5 series or AX series systems to Navisphere Manager).
For information on the server software supported with your CLARiiON
® storage system and the minimum FLARE
®
version required, refer to Minimum
FLARE revision required for your storage system, page 4
Navisphere Storage System Initialization Utility
Navisphere Host Agent
Navisphere Server Utility
Admsnap Utility
Navisphere Command Line Interface (CLI)
About the Navisphere Storage System Initialization Utility
For Fibre Channel storage systems, use the Navisphere
® initialization utility to discover storage systems and set network parameters (IP address, subnet mask, and default gateway). In addition, for iSCSI storage systems with iSCSI data ports attached to Windows servers, use the utility to set network parameters for these ports.
For CX series storage systems, an authorized service provider must install and run the initialization utility.
You can run the initialization utility from the server support CD or you can install it on a server or other host such as a Navisphere off-array management station. The only requirement is that the host be connected to the same network subnet as the storage-system management ports.
About the Navisphere Host Agent
The host agent registers the server’s host bus adapter (HBA) with the attached storage system when the host agent service starts. This action
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
5
sends the initiator records for each HBA to the storage system. Initiator records are used to control access to storage-system data.
The agent can then retrieve information from the storage system automatically at startup or when requested by Navisphere Manager or CLI.
The host agent can also:
Send operating system drive mapping information to the attached
CLARiiON® storage systems.
Monitor storage-system events and notify personnel by email, page, or modem when any designated event occurs.
Retrieve LUN world wide name (WWN) and capacity information from Symmetrix® storage systems.
About the Navisphere Server Utility
The server utility allows you to perform the following functions:
Update server information to the storage system
— Lets you send the server name and IP address to the storage system and, if needed later on, allows you to update or view this data.
Verify server high availability (HA)
— Lets you determine if the server is configured for high availability (HA) by verifying that the server has at least one connection path to each storage-system
SP, and that PowerPath
® or some other failover software, such as
VMware native, DMP, PV Links, or HP native failover for 11iV3 is running. The utility does not detect any other native failover software, such as Sun StorEdge Traffic Manager or Linux native multipath (MPIO).
Use the snapshot feature (Navisphere Express only)
— On storage systems with Navisphere Express, you can start and stop a snapshot on the source server (server assigned to the source virtual disk or source LUN), or you can allow or remove access to the snapshot by the secondary server (server assigned to the snapshot).
On AX4–5 series storage systems with Navisphere Manager, you cannot use the server utility to manage snapshots. Instead, you must install and use the admsnap utility.
6
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
You can run the Navisphere Server Utility from the CD or you can install it on the servers that are connected to the storage system. We strongly recommend that you install the utility on each server that is connected to the storage system.
About the Admsnap Utility
The Admsnap Utility is an executable program that you can run interactively or with a script to manage SnapView
® clones and snapshots. The Admsnap Utility resides on the servers connected to the storage system with the SnapView driver installed.
Use admsnap commands to:
Scan for new storage devices
Make storage devices inaccessible to the server operating system
Flush cached data to disk
List current snapshot devices
Map and unmap to a SnapView session
Start and stop a SnapView session
If you upgraded your storage system to Navisphere Manager and want to manage snapshots, you must use the SnapView software and the Admsnap
Utility. For more information on SnapView and admsnap, refer to the
Navisphere Manager help and the EMC SnapView Command Line Interfaces
Reference.
About the Navisphere CLI
The CLI complements, or is an alternative to Manager. It provides a command line interface for storage-system management, including storage provisioning, status and configuration information retrieval, and control. You can use the CLI to automate management functions through shell scripts and batch files. For more information, refer to the
EMC Navisphere Command Line Interface (CLI) Reference Guide.
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
7
Finding current information
The most up-to-date information about the CLARiiON® server software is posted on the EMC Powerlink® website. We recommend that you download the latest information before you install any server software.
To access EMC Powerlink, use the following link:
http://Powerlink.EMC.com
After you log in, select Support > Technical Documentation and
Advisories
and find the following:
Navisphere Host Agent/CLI and Utilities Release Notes.
EMC SnapView Command Line Interfaces Reference (P/N 069001181).
For the most current management and security content, refer to the
EMC Navisphere Manager help.
For Navisphere CLI commands, refer to the latest revision of the EMC Navisphere Command Line Interface (CLI) Reference (P/N
300–003–628).
8
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
Installing and removing the Navisphere Storage System Initialization
Utility
EMC recommends that you install the utility on the server; however, you can run the Navisphere Storage System Initialization Utility from the server support CD.
IMPORTANT
If you have a Linux virtual machine, refer to one the following docs:
For VMware ESX Server systems – EMC CLARiiON Server Support
Products for VMware ESX Servers and Virtual Machines Installation
Guide
For Windows Server 2008 with Hyper-V system– EMC CLARiiON
Server Support Products for Windows Server 2008 with Hyper
Installation Guide
If you do not know if your system is a virtual machine, consult your system administrator.
Installation prerequisites
To initialize a storage system using the Navisphere Storage System
Initialization Utility, the server must meet the following requirements:
Run a supported version of the operating system.
Be connected to the same subnet as the 10/100 management ports of the storage system that you want to initialize. This server may also be a server with Fibre Channel connections to the storage system.
If you have an earlier version of the storage system initialization utility installed, you must uninstall it before installing an updated version.
Installing the Navisphere Storage System Initialization Utility on a Linux server
EMC recommends that you install the most recent version of the
Navisphere Storage System Initialization Utility software that is appropriate for your configuration. You can download the most recent version from the software download page on the Powerlink website (CX4 series, CX3 series, CX series, and AX4-5 series) or on the
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
9
10
storage-system support website (AX series). You can also install the software from the server support CD (any storage system); however, the CD may not contain the most recent version for your configuration.
1. Log in to the root account of a Linux server that is on the same subnet as the storage system.
2. At the command line prompt, look for an existing initialization utility:
rpm -qi naviinittool
If an earlier version of the software has been installed, you must remove it before continuing.
3. To download the software for CX4 series, CX3 series, CX series, or
AX4–5 series storage systems, do the following: a. From the Navigator drop-down menu at the top right of the
Powerlink
website, select Software Downloads and Patches.
b. Select the appropriate initialization utility version to download and select the option to save the zip file to your server.
c. At the command line prompt, navigate to the directory where you saved the zip file and unzip the file.
unzip Linux-INITTOOL-
version.zip where version is the version listed in the filename.
d. Enter the one of the following commands to install the initialization utility package:
Linux servers:
rpm -ivh naviinittool-
version-build.noarch.rpm
Power Linux servers (version 6.28.10 or higher):
rpm -ivh naviinittoolPowerPC-
version-build.ppc64.rpm where version and build are the version number and the build number of the initialization utility.
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
If you are upgrading the utility on the server, use -U in place of -i.
4. To download the software for AX series storage systems, do the following: a. On the storage-system support website select the link to download software.
b. Select the appropriate Navisphere Storage System Initialization
Utility version to download and select the option to save the zip file to your server.
c. At the command line prompt, navigate to the directory where you saved the zip file and unzip the file.
unzip Linux-INITTOOL-
version.zip where version is the version listed in the filename.
d. Enter the following command to install the initialization utility package:
rpm -ivh naviinittool-
version-build.noarch.rpm where version and build are the version number and the build number of the initialization utility.
If you are upgrading the utility on the server, use -U in place of -i.
5. To install the software from the server support CD (any storage system), do the following: a. In the drive of a Linux server, insert the server support CD, which shipped with the storage system or the upgrade kit (for
AX4-5 series or AX series systems upgrading to Navisphere
Manager).
b. From a console window, mount the CD using the mount command for your operating system version.
c. From the CD directory, change to the Linux directory:
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
11
cd linux
This directory contains the Linux install packages.
d. Install the initialization utility:
rpm -ivh naviinittool.noarch.rpm
If you are upgrading the utility on the server, use -U in place of -i.
e. When installation is complete, remove the CD from the server’s
CD drive.
Removing the Navisphere Storage System Initialization Utility from a Linux server
1. Log in to the server as root or as a member of an administrative group.
2. Open a terminal window and enter the following command to remove the Storage System Initialization Utility:
rpm -e naviinittool
12
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
Running the Navisphere Storage System Initialization Utility
You can start the storage system initialization utility from the server on which it is installed or from the server support CD. The storage system initialization utility has three methods for executing commands — a user interface (UI) version, a command line interface that can be scripted, or a text-based utility that cannot be scripted.
Before continuing, make sure that the storage system is powered up completely.
For storage-system initialization, connect the server from which you are running the utility and the storage system to the same network subnet. Once you have assigned an IP address to the storage system, the server and storage system can be on different subnets.
Starting the initialization utility on a Linux server
To start the text-based version of the utility, enter:
/opt/Navisphere/bin/naviinittoolcli
To start the command line version of the utility, enter:
/opt/Navisphere/bin/naviinittoolcli
and any of the command line
switches in Using the command line initialization utility, page 15.
Starting the initialization utility on a Linux server from the CD
To start the text-based or command line version of the initialization utility from the CD, do the following:
1. On the server, log in to the root account.
2. In the server’s drive, insert the server support CD, which shipped with the storage system or the upgrade kit (for AX4-5 series or AX series systems upgrading to Navisphere Manager).
3. From a console window, mount the CD-ROM drive by entering the following command:
mount /mnt/cdrom
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
13
4. Change to the CD-ROM directory by entering the following command:
cd /mnt/cdrom
5. Navigate to the Linux directory:
cd Linux
6. Depending on which version of the initialization utility you want to start and run from the CD, enter the appropriate command:
Text-based version — ./naviinittoolcli
Command line version — ./naviinittoolcli and any of the command
line switches in Using the command line initialization utility, page 15.
Using the text-based initialization utility
After you start the utility, it automatically scans the subnet for supported storage systems. When this storage-system discovery operation is complete, the utility lists, by hardware serial number, all uninitialized and initialized storage systems it found. The hardware serial number for CX4 series storage systems is on a hanging tag at the rear of the storage system.The hardware serial number for CX3 and
CX series storage systems is on a blue label located on the SPE chassis behind the front bezel.The hardware serial number for AX4-5 and AX series storage systems is on a blue label on the rear of the chassis.
If the storage system you are installing was not discovered, verify the cable connections between the storage system and the host running the utility.
Use the information in the “Storage-System Management Ports” worksheet from the storage-system configuration planning guide, planning worksheets document, or the administration worksheet, and follow the instructions on the screen to change the storage system’s name, to set the network parameters for the storage-system 10/100 management ports, and to set the storage system’s management user account settings.
14
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
For a CX4 or CX3 series storage system
If you entered an SP IP address for the first time or changed an SP IP address, the utility reboots the storage system, and the SP fault light on the back of each SP starts blinking. The reboot takes several minutes to complete. When it has completed, the SP fault light (LEDs) on each
SP stops blinking and remains off.
For an AX4-5 series storage system
If you entered an SP IP address for the first time or changed an SP
IP address, the utility reboots the storage system, and green activity lights flash. The reboot takes 5 to 6 minutes to complete. When it has completed, the power button on each SP remains solid/steady green.
For an AX series storage system
If you entered an SP IP address for the first time or changed an SP IP address, the utility reboots the storage system and the SP Boot/Fault light on the back of each SP starts blinking. The reboot takes several minutes to complete. When it has completed, the SP Boot/Fault light on each SP stops blinking and remains off.
Using the command line initialization utility
After you start the command line version of the initialization utility, use any of the switches below with the naviinittoolcli .
eula
[-language language]
discover
[-all] [-xml]
configure
–serial serialnumber [-file filename] [–ipa
spAIpaddress|–sphosta spAhostname] [-ipb spBIpaddress
|–sphostb spBhostname] [–mask subnetmask] [–gateway gatewayaddress]
[-user username] [–password password] [–storagename storageName]
[-ipv6mode |automatic|disable| [manual [-globalprefix prefix
[-ipv6gateway ipv6gateway]] [ -help] where:
eula
Displays the EMC end-user license agreement (EULA) in the specified language.
-language language The default language is English.
Currently, the only valid language is English.
discover
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
15
Discovers and displays a list of partially initialized storage systems.
-all Discovers and displays a list of initialized and partially initialized storage systems.
-xml Specifies that the output is in xml format.
configure
Specifies the network parameters for the specified storage system.
-serial serialnumber Specifies the serial number of the storage system you want to initialize.
-file filename
-ipa spAipaddress |-sphosta spAhostname
Specifies the name of the file that will store all the network parameters.
Specifies the IP address of SP A, or the server name for SP A for the specified storage system.
-ipb spBipaddress |-sphostb spBhostname Specifies the IP address of SP B, or the server name for SP B for the specified storage system.
-mask subnetmask
-gateway gateway
-user username
-password password
-storagename storagename
-help
Specifies the subnet mask for the specified storage system.
Specifies the gateway for the specified storage system.
Specifies the storage-system login username.
Specifies the storage-system login password.
Specifies the name for the specified storage system.
Displays the help screen and does not start the initialization process
16
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
-ipv6mode automatic | disable |
[manual –globalprefix prefix –ipv6gateway
ipv6gateway]
Specifies the configuration type for the IPv6 network. Refer to the IPv6 configuration type table below for details. IPv6 is supported with CX4 series systems only.
Table 2 IPv6 parameter values based on IPv6 configuration type (CX4 series systems only)
Existing configuration type
(What you see when you open the initialization utility)
New configuration type
(What you see after changing the configuration type)
Disabled Auto Manual
Disabled
All IPv6 parameteers are blank and grayed out.
IPv4 will be used
All IPv6 parameters are set to
TBD*
Link Local:
TBD*
Global IP: TBD*
Global
Prefix:
Blank/editable
Gateway:
blank/editable
Link Local:
visible**
Auto
Current IPv6 parameters are visible but not editable.
All IPv6 parameters are blank and grayed out *
IPv4 will be used
Global IP:
Global
Prefix:
Gateway:
visible** visible/editable** visible/editable**
Manual Link Local:
Global IP:
Global
Prefix:
Gateway:
visible visible visible/editable visible/editable
All IPv6 parameters are blank and grayed out * IPv4
will be used
Current IPv6
Link Local parameter is visible. All others are set to TBD **
* After changing the configuration type from Disabled to Auto or Manual, or from Auto or Manual to Disabled, the new values will be set after the automatic reboot of the storage system. After the reboot completes, open the initialization utility again to view the new IPv6 values.
** After changing the configuration type from Manual to Auto or from Auto to Manual, a reboot is not required.
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
17
Determining whether to install the host agent or server utility
Depending on your application needs, you can install the host agent, server utility, or both on an attached server.
If you want to install both applications, you must install version 6.22.20
or later of the server utility either before or after you install the host agent. The registration feature of the server utility will be disabled and the host agent will be used to register the server’s NICs or iSCSI
HBAs to the storage system.
Prior to version 6.22.20 of the server utility, you could not install the host agent and server utility on the same server. However, you could install them on different servers that are connected to the same storage system.
If you do not want to install both applications, but want to use some of the features available in the server utility, you can run the server utility from the server support CD.
If you have an AX4-5 series or AX series storage system running
Navisphere Express, you can install only the server utility. The host agent is supported only on CX4 series, CX3 series, CX series, AX4-5 series, and AX series storage systems running Navisphere Manager.
Table 3 describes the differences between the host agent and the server
utility on a server attached to a storage system.
Depending on the version of the server utility, some of the features listed in
may not be available.
18
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
Function
Pushes LUN mapping and OS information to the storage system.
Runs automatically to send information to the storage system.
Provides high-availability
(HA) validation.
Requires network connectivity to the storage system.
Table 3 Differences between the host agent and the server utility
Host agent
Yes – LUN mapping information is displayed in the Manager UI next to the LUN icon or with the CLI using the lunmapinfo command.
Yes – No user interaction is required.
No – You can run the server utility’s
HA validation feature from the CD without having to install the server utility.
Yes – Network connectivity allows
LUN mapping information to be available to the storage system.
Server utility
AX4–5 series and AX series storage systems
Yes – LUN mapping information is displayed in the
Manager UI next to the LUN icon, or with the CLI using the -lunmapinfo command. In Navisphere Express this information is displayed in the Manage Virtual Disks page.
Note: The text
Manually Registered appears next to the hostname icon in the Manager UI indicating that the host agent was not used to register this server.
CX4 series, CX3 series, and CX series storage systems
No – LUN mapping information is not sent to the storage system. Only the server’s name, ID, and IP address are sent to the storage system.
Note: The text
Manually Registered appears next to the hostname icon in the Manager UI indicating that the host agent was not used to register this server.
AX4–5 series and AX series storage systems
No – You must manually update the information by starting the utility or you can create a script to run the utility. Since you run the server utility on demand, you have more control as to how often or when the utility is executed.
CX4 series, CX3 series, and CX series storage systems
No – You must manually update the information by starting the utility or you can create a script to run the utility. Since you run the server utility on demand, you have more control as to how often or when the utility is executed.
AX4–5 series and AX series storage systems
Currently not supported.
CX4 series, CX3 series, and CX series storage systems
Yes – The HA validation feature verifies that failover software is installed on the server and that working paths exist between the server and each SP in the storage system.
AX4–5 series and AX series storage systems
No – LUN mapping information is sent through a data path to the storage system.
CX4 series, CX3 series, and CX series storage systems
No – LUN mapping information is not sent to the storage system.
Note that if you are using the server utility to upload a high-availability report to the storage system, you must have network connectivity.
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
19
Function
Requires installation.
Host agent
Yes – You must install the host agent on the server.
Server utility
AX4–5 series and AX series storage systems
No – You can run the server utility from the CD. However, we recommend that you install it on the server.
CX4 series, CX3 series, and CX series storage systems
No – You can run the server utility from the CD. However, we recommend that you install it on the server.
Note: If you install the host agent and then version 6.22.20 or later of the server utility, the server utility’s registration service feature will not be installed. Prior to version 6.22.20 of the server utility, you could not install the host agent and server utility on the same server.
20
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
Requirements for the host agent, server utility, and CLI
To run the host agent, CLI, or server utility, your server must meet the following requirements:
Run a supported version of the Linux operating system.
For Fibre Channel connections, have the EMC CLARiiON supported HBA hardware and driver installed.
Be connected to at least one SP (two SPs for high availability) in each storage system either directly or through a switch or hub. Each
SP must have an IP connection.
For the host agent and CLI only - Be on a TCP/IP network connected to at least one SP (two SPs for high availability) in the storage system. The TCP/IP network connection allows the server to send
LUN mapping information to the storage system and it allows
Navisphere Manager or CLI to communicate with the storage system over the network.
Have a configured TCP/IP network connection to any remote hosts that you will use to manage the server’s storage systems, including: z z any server whose browser you will use to access Manager 6.X.
any Windows Server 2008, 2003, or Windows 2000 server running Storage Management Server software.
z any AIX, HP-UX, Linux, VMware ESX Server, NetWare, Solaris,
Windows Server 2003, or Windows 2000 server running the CLI.
If you want to use the CLI on the server to manage storage systems on a remote server, the server must be on a TCP/IP network connected to both the remote server and each SP in the remote server’s storage system. The remote server can be running AIX, HP-UX, Linux, Solaris, or the Windows operating system.
For information about the specific revisions of the server operating system and the storage-system FLARE and Access Logix
™ software that are required for your version of the host agent, see the release notes for the host agent
on the EMC Powerlink website. To access this website, see Finding current
.
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
21
Installing or removing the Navisphere Host Agent and CLI
You can install both the host agent and CLI, or you can install them separately. If you will install both, install the host agent first.
IMPORTANT
If you have a Linux virtual machine, refer to one the following docs:
For VMware ESX Server systems – EMC CLARiiON Server Support
Products for VMware ESX Servers and Virtual Machines Installation
Guide
For Windows Server 2008 with Hyper-V system– EMC CLARiiON
Server Support Products for Windows Server 2008 with Hyper
Installation Guide
If you do not know if your system is a virtual machine, consult your system administrator.
To modify an existing host agent configuration refer to the next section.
If you want to install the host agent and use some of the features in the server
utility, see Determining whether to install the host agent or server utility , page 18
Installing the host agent and CLI on a Linux server
EMC recommends that you install the most recent version of the
Navisphere Host Agent and CLI software that is appropriate for your configuration. You can download the most recent version from the software download page on the Powerlink website (CX4 series, CX3 series, CX series, and AX4-5 series) or on the storage-system support website (AX series). You can also install the software from the server support CD (any storage system); however, the CD may not contain the most recent version for your configuration.
1. On the Linux server, log in to the root account.
2. At a command line prompt, look for an existing host agent and CLI package by entering one of the following commands:
rpm -qa | grep navi
22
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
If an earlier version of the naviagentcli or naviagent software package is listed, you must remove it before installing the new host agent and CLI package.
3. To download the software for CX4 series, CX3 series, CX series, or
AX4–5 series storage systems with Navisphere Manager, do the following: a. From the Navigator drop-down menu at the top right of the
Powerlink
website, select Software Downloads and Patches.
b. Select the appropriate Navisphere Host Agent/CLI version to download and select the option to save the zip file to your server.
c. At the command line prompt, navigate to the directory where you saved the zip file and unzip the file.
unzip Navi_Agent_CLI_Linux-
version.zip where version is the version listed in the filename.
d. Enter the following command to install both the host agent and
CLI packages:
rpm -ivh naviagentcli-
version-build.noarch.rpm where version and build are the version and build number for the
Navisphere Host Agent/CLI.
The system displays the word navigentcli and a series of pound (#) signs. When the installation is complete, the system prompt reappears.
4. To download the software for AX series storage systems with
Navisphere Manager, do the following: a. On the storage-system support website, select the link to download software.
b. Select the appropriate Navisphere Host Agent/CLI version to download and select the option to save the zip file to your server.
c. At the command line prompt, navigate to the directory where you saved the zip file and unzip the file.
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
23
24 unzip Navi_Agent_CLI_Linux-
version.zip where version is the version listed in the filename.
d. Enter the following command to install both the host agent and
CLI packages:
rpm -ivh naviagentcli-
version-build.noarch.rpm where version and build are the version and build number for the
Navisphere Host Agent/CLI.
The system displays the word navigentcli and a series of pound (#) signs. When the installation is complete, the system prompt reappears.
5. To install the software from the server support CD (any storage system), do the following: a. In the server’s drive, insert the server support CD that shipped with your storage system or the upgrade kit (for AX4-5 series or
AX series systems upgrading to Navisphere Manager).
b. From a console window, mount the CD using the mount command for your operating system version.
c. From the CD directory, change to the Linux directory by entering the following command:
cd linux
This directory contains the Linux install packages.
d. Enter the following command to install both the host agent and
CLI packages:
rpm -ivh naviagentcli.noarch.rpm
The system displays the word navigentcli and a series of pound (#) signs. When the installation is complete, the system prompt reappears.
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
e. If you installed the software from the server support CD, unmount the CD, and then remove the CD from the CD drive.
If the File Manager window is open to the /mnt/cdrom directory, you need to close this window first before attempting to unmount the CD.
6. Verify that Navisphere Agent and/or CLI are installed by using the
rpm -qa | grep navi
command.
Before you can use the host agent or CLI, you must modify the user login scripts and configure the host agent configuration file.
7. If you have a multihomed host (multiple NIC cards installed on the host), create an agentID.txt file to ensure that the agent finds the correct NIC card.
A multihomed host machine has multiple IP addresses connected to networks; it is physically connected to multiple data links that can be on the same or different networks. When you install Navisphere Host Agent on a multihomed host, the host agent, by default, binds to the first NIC in the host. If your host is multihomed, for the host agent to successfully register with the desired CLARiiON storage system, you need to configure the host agent to bind to a specific NIC. You do this by setting up an agentID.txt file.
a. Using a text editor that does not add special formatting, create or edit a file named agentID.txt (case sensitive) in either / (root) or in a directory of your choice.
b. Add the following two separate lines to the agentID.txt file, with no special formatting:
First line:
Fullyqualified hostname of the host
Second line:
IP address of the HBA/NIC port that you want Navisphere agent to use
For example, if your host is named host28 on the domain
mydomain.com
and your host contains two HBAs/NICs,
HBA1/NIC1 with IP address 192.111.222.2 and HBA2/NIC2
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
25
with IP address 192.111.222.3, and you want the host agent to use NIC 2, you would configure agentID.txt as follows:
host28.mydomain.com
192.111.222.3
The agentID.txt file should contain only these two lines, without any formatting. The first line should contain the hostname and the second line should contain the IP address of the HBA/NIC port as described above. Both lines should end with a carriage return. As a result, the cursor will be on a third line but this line should not contain any text.
c. Save the agentID.txt file.
d. If you created the agentID.txt file in a directory other than root, for host agent to restart after a system reboot using the correct path to the agentID.txt file, set the environment variable
EV_AGENTID_DIRECTORY
to point to the directory where you created agentID.txt.
e. If a HostIdFile.txt file is present in the directory shown for your operating system, delete or rename it. The HostIdFile.txt file is located in /var/log/HostIdFile.txt.
f.
Stop and then restart the host agent.
g. Once the host agent has restarted, verify that the host agent is using the IP address that is entered in the agentID.txt file. To do this, view the new HostIdFile.txt file. You should see the IP address that is entered in the agentID.txt file.
Installing the Navisphere CLI on a Linux server
EMC recommends that you install the most recent version of the
Navisphere CLI software that is appropriate for your configuration.
You can download the most recent version from the software download page on the Powerlink website (CX4 series, CX3 series, CX series, and
AX4-5 series) or on the storage-system support website (AX series).
You can also install the software from the server support CD (any storage system); however, the CD may not contain the most recent version for your configuration.
1. On the Linux server, log in to the root account.
2. At the command line prompt, look for any existing CLI by typing:
26
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
rpm -qi navicli
If an earlier version of the software has been installed, you must remove it before continuing.
3. To download the software for CX4 series, CX3 series, CX series, or
AX4–5 series storage systems, do the following: a. From the Navigator drop-down menu at the top right of the
Powerlink
website, select Software Downloads and Patches.
b. Select the appropriate Navisphere CLI version to download and select the option to save the zip file to your server.
c. At the command line prompt, navigate to the directory where you saved the zip file and unzip the file.
unzip Linux_navicli-
version.zip where version is the version listed in the filename.
d. Enter the following command to install the CLI package:
Linux servers:
rpm -ivh navicli-
version-build.noarch.rpm
Power Linux servers (version 6.28.10 or higher):
rpm -ivh naviseccli_PowerPC-
version-build.ppc64.rpm
This will install Secure CLI only.
where version and build are the version and build number for the
Navisphere CLI.
The system displays the word navicli and a series of pound
(#) signs. When the installation is complete, the system prompt reappears.
4. To download the software for AX series storage systems with
Navisphere Manager, do the following:
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
27
28
a. On the storage-system support website, select the link to download software.
b. Select the appropriate Navisphere CLI version to download and select the option to save the zip file to your server.
c. At the command line prompt, navigate to the directory where you saved the zip file and unzip the file.
unzip Linux_navicli-
version.zip where version is the version listed in the filename.
d. Enter the following command to install the CLI package:
rpm -ivh navicli-
version-build.noarch.rpm where version and build are the version and build number for the
Navisphere CLI.
The system displays the word navicli and a series of pound
(#) signs. When the installation is complete, the system prompt reappears.
5. To install the software from the server support CD (any storage system), do the following: a. In the server’s drive, insert the server support CD that shipped with your storage system or the upgrade kit (for AX4-5 series or
AX series systems upgrading to Navisphere Manager).
b. From a console window, enter the following command:
mount /mnt/cdrom
The CD can also be mounted from either the Gnome or KDE desktop.
c. Change to the CD directory by entering the following command:
cd /mnt/cdrom
d. Change to the Linux directory by entering the following command:
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
cd linux
This directory contains the Linux install packages.
e. Enter the following command to install the CLI package:
rpm -ivh navicli.noarch.rpm
The system displays the word navicli and a series of pound
(#) signs. When the installation is complete, the system prompt reappears.
f.
If the File Manager window is open to the /mnt/cdrom directory, you need to close this window first before attempting to unmount the CD. Then enter the following commands:
cd umount /mnt/cdrom
6. Verify that Navisphere CLI is installed by using the rpm -qa | more command.
Modifying user login scripts
To use navicli commands at the root prompt without typing a leading
./
before the commands (for example, ./navicli getagent), you must modify the $PATH environment variable in the user login script.
Follow the steps listed below to modify the environment variable
PATH
:
1. Add /opt/Navisphere/bin to $PATH:
PATH=$PATH:/opt/Navisphere/bin export PATH
To verify the path enter:
echo $PATH
2. Set the environment variable $PATH for all login sessions: a. For the user profile, edit $HOME/.bash_profile b. For the user startup script, edit $HOME/.bashrc
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
29
3. If you are setting up a new server, go to Running the Navisphere Host
Agent , page 34. If you are just upgrading the host agent or CLI on
an existing system, you have finished the upgrade.
Removing the host agent and CLI from a Linux server
To avoid losing site-specific information, copy the agent configuration file
(agent.config) to a safe location before removing any Navisphere software.
1. Log in as root or as a member of an administrative group.
2. Open a terminal window and depending on which version you are running, enter one of the following commands to stop the host agent, and then uninstall the host agent and CLI files.
Version 6.16.x.x.x (or later)
/etc/init.d/naviagent stop rpm -e naviagentcli
| naviagent
Version 6.7.0.4.7 (or earlier)
/etc/init.d/naviagent stop rpm -e naviagentcli-
version | naviagent-version
For example, rpm -e naviagentcli-6.7.0.4.7-1 or rpm -e
naviagent-6.6.0.4.7-1
The system removes all files required to run the host agent and CLI.
A backup copy of the configuration file is saved in /etc/Navi-
sphere/agent.config.rpmsave
.
Removing the Navisphere CLI from a Linux server
1. Log in to the Linux server as root or as a member of an administrative group.
2. Open a terminal window and enter the following command to remove CLI:
rpm -e navicli
The system removes all files required to run Navisphere CLI.
30
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
Configuring the Navisphere Host Agent
Before you can use the Navisphere CLI navicli register command to configure your storage system, you must make sure the host agent
configuration file includes a privileged user, as described in Adding
The pathname of the host agent configuration file is /etc/Navisphere/agent.con-
fig
.
If you are configuring a legacy storage system, refer to revision A10 of this guide.
A legacy system is an FC series storage system that is not running storage management server software.
Adding privileged users
If you will use Navisphere CLI to configure any storage system, the host agent configuration file must include an entry that defines the person who will issue the CLI commands as a privileged user.
To define a privileged user, add a local or remote privileged user by adding the appropriate entry below.
For a local user:
user
name
For a remote user:
user
name@hostname
where name is the person’s account name and hostname is the name of the remote server the person will be using.
The default host agent configuration file includes a user root entry.
Saving the host agent configuration file
1. Save the host agent configuration file.
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
31
2. If you have finished adding information to the host agent configuration file, stop and restart the host agent by entering the following commands:
/etc/init.d/naviagent stop
/etc/init.d/naviagent start
32
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
Using the event monitor configuration file
The Navisphere Host Agent can monitor storage-system events and take such action as sending email or paging you if specified events occur. The event monitor that ships with Navisphere Manager provides an interactive way to define these events and actions. If you do not have event monitor, you can still define such events and actions by editing the event monitor configuration file.
/etc/Navisphere/Navimon.cfg
The file is self-documenting; that is, text in it describes how to define events and the actions you want taken if the events occur. You can test the file after editing it using the Navisphere CLI command
responsetest
, as explained in the Navisphere Command Line Interface
Reference.
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
33
Running the Navisphere Host Agent
This section describes how to test the host agent connections and how to start and stop the host agent.
Starting and stopping the Navisphere Host Agent
The host agent starts automatically when you bring the server up to init level 3. When you first start the host agent, look at the system log for the server’s operating system to make sure the agent started and no device errors occurred. The system log is located in /var/log/messages.
When a storage system experiences heavy input/output traffic (that is, applications are using the storage system), information may not be reported to the host agent in a timely manner, resulting in the host agent taking several minutes to execute a storage-system management task. This behavior is most evident when one host agent is managing multiple storage systems. Also, if the
SP event log is large and the host agent configuration file is set up to read all events, it may take a few minutes for the host agent to start.
Starting the host agent
Log in as root and enter this command:
/etc/init.d/naviagent start
Stopping the host agent
Log in as root and enter this command:
/etc/init.d/naviagent stop
Testing the host agent connections
Before continuing, you should test the host agent connections as follows:
1. Start the host agent as described in Starting and stopping the
Navisphere Host Agent, page 34.
2. Look for any errors on the console and in the operating system log to make sure the agent started and no device errors occurred.
34
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
3. Verify that the host agent on the server can see the storage system as follows: a. Enter the following CLI command:
naviseccli
|navicli [-d device]| -h hostname port
-list -hba
You cannot specify both the –d switch and –h switch.
where:
[-d device] is the device name for the storage system (only supported with legacy systems).
-h
hostname is the IP address of the SP.
For each HBA in the server, a listing similar to the following will be displayed. For storage systems in a SAN (shared storage) environment, the listing includes HBAs in all connected hosts.
Information about each HBA:
HBA UID: 10:00:00:60:B0:3E:46:AC:10:00:00:60:B0:3E:46:AC
Server Name: siux134
Server IP Address: 128.221.208.134
HBA Model Description:
HBA Vendor Description:
HBA Device Driver Name:
Information about each port of this HBA:
SP Name: spa
HBA Devicename: sp0
Trusted: NO
Logged In: YES
Source ID: 1
Defined: YES
Initiator Type: 0
Storage Group Name:
Storage Group 134 b. In the listing, examine the information for each HBA installed in the host to verify the path from the HBA to the SP.
Host agent status and error logging
While the system is running, the operating system tracks information about host agent events and host agent errors, and places this information in log files on the server.
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
35
The host agent error log tracks information about the host agent’s startup, the host agent shutdown, and errors that might occur, such as the host agent’s inability to access a device in the configuration file. If problems occur, log files are a good place to start your troubleshooting.
Host agent events and errors are logged in /var/log/agent.log. System events are logged in /var/log/messages.
36
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
Installing and removing the Navisphere Server Utility
This section describes how to install the Navisphere Server Utility.
IMPORTANT
If you have a Linux virtual machine, refer to one the following docs:
For VMware ESX Server systems – EMC CLARiiON Server Support
Products for VMware ESX Servers and Virtual Machines Installation
Guide
For Windows Server 2008 with Hyper-V system– EMC CLARiiON
Server Support Products for Windows Server 2008 with Hyper
Installation Guide
If you do not know if your system is a virtual machine, consult your system administrator.
Installing the Navisphere Server Utility on a Linux server
EMC recommends that you install the most recent version of the
Navisphere Server Utility software that is appropriate for your configuration. You can download the most recent version from the software download page on the Powerlink website (CX4 series, CX3 series, CX series, and AX4-5 series) or on the storage-system support website (AX series). You can also install the software from the server support CD (any storage system); however, the CD may not contain the most recent version for your configuration.
1. Log in to the root account.
2. At the command line prompt, look for any existing server utility:
rpm -qi naviserverutil
If you have an AX100 series storage system and a previous version of the server utility was not detected with the command above, try entering rpm
-qi axnaviserverutil
.
3. If an earlier version of the software has been installed, you must remove it before continuing.
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
37
38 rpm -e naviserverutil
4. To download the software for CX4 series, CX3 series, CX series, or
AX4–5 series storage systems, do the following: a. From the Navigator drop-down menu at the top right of the
Powerlink
website, select Software Downloads and Patches.
b. Select the appropriate Navisphere Server Utility version to download and select the option to save the zip file to your server.
c. At the command line prompt, navigate to the directory where you saved the zip file and unzip the file.
unzip Linux_HOSTUTIL-
version.zip where version is the version listed in the filename.
d. Install the Navisphere Server Utility on the server:
Linux servers (except PLinux and SuSE ia64 servers):
rpm -ivh naviserverutil
.platform.rpm
Power Linux servers (version 6.28.10 or higher):
rpm -ivh naviinittoolPowerPC-
version-build.ppc64.rpm
SuSE ia64 servers:
rpm -i naviserverutil_suse
version-build.platform.rpm where version and build are the version number and the build number of the server utility and platform is your Linux platform number (for example, i386, ia64, or x86-64).
If you are upgrading the utility on the server, use -U in place of -ivh.
The installation process adds a line to the /etc/rc.d/rc.local file that starts the server utility on reboot, provided root has execute permission for the /etc/rc.d/rc.local file.
5. To download the software for AX series storage systems, do the following:
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
a. On the storage-system support website, select the link to download software.
b. Select the appropriate Navisphere Server Utility version to download and select the option to save the zip file to your server.
c. At the command line prompt, navigate to the directory where you saved the zip file and unzip the file.
unzip Linux_HOSTUTIL-
version.zip where version is the version listed in the filename you downloaded.
d. Install the Navisphere Server Utility on the server:
rpm -ivh naviserverutil
.platform.rpm
For a SuSE ia64 system, use the following command:
rpm -i naviserverutil_suse
version-build.platform.rpm where version and build are the version number and the build number of the server utility and platform is your Linux platform number (for example, i386, ia64, or x86-64).
If you are upgrading the utility on the server, use -U in place of -ivh.
The installation process adds a line to the /etc/rc.d/rc.local file that starts the server utility on reboot, provided root has execute permission for the /etc/rc.d/rc.local file.
6. To install the software from the server support CD (any storage system), do the following: a. In the server’s drive, insert the server support CD, which shipped with the storage system or the upgrade kit (for AX4-5 series or AX series systems upgrading to Navisphere Manager).
b. From a console window, mount the CD using the mount command for your operating system version.
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
39
c. From the CD directory, change to the Linux directory by entering the following command:
cd linux
This directory contains the Linux install packages.
d. Install the Navisphere Server Utility on the server:
rpm -ivh naviserverutil
.platform.rpm
For a SuSE ia64 system, use the following command:
rpm -i naviserverutil_suse
.platform.rpm where platform is your Linux platform number (for example,
i386
, ia64, or x86-64).
If you are upgrading the utility on the server, use -U in place of -ivh.
The installation process adds a line to the /etc/rc.d/rc.local file that starts the server utility on reboot, provided root has execute permission for the /etc/rc.d/rc.local file.
e. Remove the CD from the server’s CD drive.
Removing the server utility from a Linux server
1. Log in as root or as a member of an administrative group.
2. Open a terminal window and, depending on which version of the server utility is installed, enter the appropriate command to remove the server utility:
rpm -e naviserverutil
or
rpm -e axnaviserverutil
40
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
To determine which version is installed, enter rpm -qi naviserverutil or
rpm -qi axnaviserverutil
. If the utility is installed, information about the utility is displayed.
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
41
Running the Navisphere Server Utility
This section describes how to start and use the server utility. You can run the server utility from the server or from the server support CD.
Starting the Navisphere Server Utility on a Linux server
1. Open a console window.
2. Navigate to the Navisphere bin directory and run the server utility:
/opt/Navisphere/bin/naviserverutilcli
Starting the Navisphere Server Utility on a Linux server from the CD
1. Log in to the root account.
2. In the server’s drive, insert the server support CD, which shipped with the storage system or the upgrade kit (for AX4-5 series or AX series systems upgrading to Navisphere Manager).
3. From a console window, mount the CD using the mount command for your operating system version.
4. From the CD directory, change to the Linux directory by entering the following command:
cd linux
This directory contains the Linux install packages.
5. Run the server utility:
./naviserverutilcli
Using the Navisphere Server Utility
The Navisphere Server Utility allows you to perform the following functions:
Update server information on the storage system
Perform snapshot tasks (Navisphere Express only)
42
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
Generate a high-availablity report
Updating server information on the storage system
The Update Server Information option allows you to send information about the server to all connected storage systems. To update server information, select option 1 from the server utility’s Welcome screen, and follow the instructions on the utility.
Performing snapshot tasks
For information on using the snapshot tasks option, refer to the
Navisphere Express online help.
Generating a high-availability report
The Generate high availability report option (option 3) and the
naviserverutilcli hav
command determine if the server is configured for high availability by verifying that the server has at least one connection path to each storage-system SP, and that PowerPath or some other failover software, such as DMP, is running. The utility will not detect any other native failover software, such as Linux native multipath (MPIO).
After the verification, the utility generates a summary report and saves it to the server. If you issue the -upload switch with the
naviserverutilcli hav
command, the utility also sends the report to the specified storage system.
Generate a high-availability report to:
check the status of a server.
prepare for software installation on a storage system.
For AX4 systems only
— Use the -upload switch to upload the HA report to the storage system only if you will use the Navisphere Software Assistant to install new software. We strongly recommend that you use the Software
Assistant, and not the -ndu install command to update your software. The
-ndu install
command does not perform the same pre-installation validation checks as the Software Assistant. The Software Assistant is included in the
Navisphere Service Taskbar.
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
43
Checking the status of a server
To periodically check the high-availability status of a server, you can select option 3 from the server utility’s Welcome screen, and follow the instructions in the utility to generate a high-availability report, or issue the naviserverutilcli hav[-directory | -d outputdirectory] command.
where:
-directory | -d
outputdirectory
Specifies the directory to which you want to deposit the report on the server. This switch is required only if you are running the server utility from the CD. Otherwise the report is automatically saved to the Navisphere Server Utility installation directory.
If the server utility is installed on your server and you specify a directory, the directory you specify will override the server utility’s installation directory.
Preparing for software installation on a storage system
If you are generating a high-availability report as a prerequisite to updating storage-system software, you need to upload this report to the storage system prior to installing the software on the storage system.
To generate and upload an HA report, issue the following command from the directory in which you installed the utility:
naviserverutilcli hav -upload -ip
IPaddress |-h
IPaddress|network_name -user|-u username -password|-p
userpassword -scope|-s scopelevel -secfilepath securityfilepath
-port 443|2163
[-directory | -d outputdirectory] where:
44
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
-ip IPaddress
-h IPaddress |
network_name
-user | -u
username
-password | -p
userpassword
Specifies the IP address of an SP on the storage system to which you will upload the report. You cannot use this switch in conjunction with the -h switch.
Specifies the IP address or the network name of an SP on the storage system to which you will upload the report. You cannot use this switch in conjunction with the -ip switch.
Specifies the login name for the storage system. You must use this switch in conjunction with the -password | -p and -scope | -s switches. You
cannot use this switch in conjunction with the -secfilepath switch.
Specifies the password required for access to the storage system. You must use this switch in conjunction with the -user | -u and -scope | -s switches. You cannot use this switch in conjunction with the -secfilepath switch.
-scope | -s
scopelevel
-secfilepath
securityfilepath
Specifies the level of access this username and password has to the storage system: 0 = global; 1 = local; 2 = LDAP. You must use this switch in conjunction with the -user | -u and -password | -p switches. You
cannot use this switch in conjunction with the -secfilepath switch.
Searches the security file for the specified IP address. If the utility does not find the specified IP address, then the utility will use the default entry in the security file.
A security file is required to run this switch. For information on how to create a security file, refer to the EMC Navisphere Command Line (CLI)
Reference guide.
You cannot use this switch in conjunction with the -user | -u, -password |
-p , and -scope | -s switches.
-port 443 | 2163 Specifies the Navisphere Management Server port number. The default is 443.
-directory | -d
outputdirectory
Specifies the directory to which you want to deposit the report on the server. This switch is required only if you are running the server utility from the CD. Otherwise the report is automatically saved to the
Navisphere Server Utility installation directory.
If the server utility is installed on your server and you specify a directory, the directory you specify will override the server utility’s installation directory.
After uploading the HA report
In addition to running the server utility to validate server high availability, we strongly recommend that you perform the following manual checks.
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
45
Verify support of software and hardware
— Make sure that you have verified that all software and hardware is supported according to the EMC E-Lab™ Interoperability Navigator and support matrices.
This tool does not verify that you are running supported switch firmware, nor that you are using redundant switches (recommended).
Upgrading storage–system software
— If you are about to perform a storage-system online software upgrade or you added an HBA, a
LUN, or changed connectivity (added a path or changed zoning): z Make sure that you have validated all software and hardware that are supported and interoperable according to EMC E-Lab
Interoperability Navigator and support matrices.
z Verify that all LUNs (virtual disks) that your servers will access during the upgrade are under path management software control. For servers running PowerPath and DMP, see the
Failover Software section on the Details tab of the report and locate these LUNs. If they are not in the list, the server will lose access to those LUNs during the software upgrade.
46
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
Installing and removing the Admsnap Utility
EMC strongly recommends that you install admsnap on all servers connected to a storage system that has the SnapView driver installed.
IMPORTANT
If you have a Linux virtual machine, refer to one the following docs:
For VMware ESX Server systems – EMC CLARiiON Server Support
Products for VMware ESX Servers and Virtual Machines Installation
Guide
For Windows Server 2008 with Hyper-V system– EMC CLARiiON
Server Support Products for Windows Server 2008 with Hyper
Installation Guide
If you do not know if your system is a virtual machine, consult your system administrator.
Installation prerequisites
Before you can install and use the Admsnap Utility, you must:
Install SnapView on a supported CLARiiON storage system. For a list of supported storage systems, refer to the release notes for
SnapView and admsnap.
Enable data access control on the same CLARiiON storage system.
Installing the Admsnap Utility on a Linux Server
EMC recommends that you install the most recent version of the
Admsnap Utility software that is appropriate for your configuration.
You can download the most recent version from the software download page on the Powerlink website (CX4 series, CX3 series, CX series, and
AX4-5 series) or on the storage-system support website (AX series).
You can also install the software from the server support CD (any storage system); however, the CD may not contain the most recent version for your configuration.
1. Log in as root or as a member of an administrative group.
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
47
48
2. Open a terminal window and enter the following command to list any admsnap package that may be currently installed:
rpm -qi admsnap
3. Examine the list for an earlier version of admsnap.
If an earlier version is installed, remove it as described in Removing
the Admsnap Utility from a Linux server, page 51.
4. To download the software for CX4 series, CX3 series, CX series, or
AX4–5 series storage systems with Navisphere Manager, do the following: a. From the Navigator drop-down menu at the top right of the
Powerlink
website, select Software Downloads and Patches.
b. Select the appropriate Admsnap Utility version to download and select the option to save the zip file to your server.
c. At the command line prompt, navigate to the directory where you saved the zip file and unzip the file.
unzip admsnap_
version.zip where version is the version listed in the filename.
d. Install admsnap using the rpm -ivh command (Red Hat) or the
yast
command (SuSe).
Red Hat Linux users:
rpm -ivh admsnap-
version-build.platform.rpm
SuSe Linux users:
yast -l SuSe_admsnap-
version-build.platform.rpm
SuSe Linux users with PLinux (version 6.28.10 or higher):
yast -l admsnap_Linux_ppc64_enUS_
version.rpm
The software is installed in the directory /usr/admsnap with the following files:
/usr/admsnap/admsnap
/usr/admsnap/man/man1/admsnap.1
/usr/admsnap/readme
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
5. To install the software for AX series storage systems with
Navisphere Manager, do the following: a. On the storage-system support website, select the link to download software.
b. Select the appropriate Admsnap Utility version to download section and select the option to save the zip file to your server.
c. At the command line prompt, navigate to the directory where you saved the zip file and unzip the file.
unzip admsnap_
version.zip where version is the version listed in the filename.
d. Install admsnap using the rpm -ivh command (Red Hat) or the
yast
command (SuSe).
Red Hat Linux users — use the following command:
rpm -ivh admsnap-
version-build.platform.rpm where version and build are the version number and the build number of the Admsnap Utility and platform is your Linux platform number.
SuSe Linux users — use the following command:
yast -i SuSe_admsnap-
version-build.platform.rpm where version and build are the version number and the build number of the Admsnap Utility and platform is your Linux platform number (see the Red Hat examples above).
The software is installed in the directory /usr/admsnap with the following files:
/usr/admsnap/admsnap
/usr/admsnap/man/man1/admsnap.1
/usr/admsnap/readme
6. To install the software from the server support CD (any storage system), do the following: a. In the server’s drive, insert the server support CD that shipped with your storage system or the upgrade kit (for upgrading
AX4-5 series or AX series systems to Navisphere Manager).
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
49
50
b. From a console window, mount the CD using the mount command for your operating system version.
c. From the CD directory, change to the Linux directory by entering the following command:
cd linux
This directory contains the Linux install packages.
d. List the filenames on the CD:
ls
You will see four admsnap rpm packages for different platforms.
These rpm packages are for the Intel 64-bit platform (ia64), AMD processor-based Linux or Intel Xeon-based Linux platform
(x86_64), Intel 32-bit Linux platform (i386), and SuSE Linux platform (ia64).
e. Install admsnap using the rpm -ivh command (Red Hat) or the
yast
command (SuSe).
Red Hat Linux users — use the following command:
rpm -ivh admsnap
.platform.rpm where platform is your Linux platform number.
For example:
rpm -ivh admsnap.i386rpm
rpm -ivh admsnap.ia64.rpm
rpm -ivh admsnap.x86_64.rpm
SuSe Linux users — use the following command:
yast -i admsnap
.platform.rpm where platform is your Linux platform number (see the Red
Hat examples above).
The software is installed in the directory /usr/admsnap with the following files:
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
/usr/admsnap/admsnap
/usr/admsnap/man/man1/admsnap.1
/usr/admsnap/readme
f.
Unmount (umount) the CD file system by entering:
cd umount /dev/cdrom
g. Remove the CD from its drive.
You have installed admsnap on a Linux server.
7. Verify that the correct version of admsnap is installed by entering the following command:
/usr/admsnap/admsnap help
This command displays a message about the help command, which includes the revision number of the installed admsnap software.
8. Configure MANPATH to access the Linux man pages. Edit the /etc/man.config file by adding the following lines:
MANPATH /usr/admsnap/man
9. Configure sg devices by using the MAKEDEV utility. For information on how to use the MAKEDEV utility, refer to the
MAKEDEV man pages.
Removing the Admsnap Utility from a Linux server
1. Log in as root or as a member of an administrative group.
2. Open a terminal window and enter the following command to list any admsnap package that is currently installed:
rpm -q admsnap
3. To remove the previous version of the admsnap software, enter:
rpm -e
name
where name is the admsnap program name displayed by the command in step 2.
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
51
Running the Admsnap Utility
Refer to the EMC SnapView Command Line Interfaces Reference for information on running admsnap commands.
52
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
Copyright© 2004–2009 EMC Corporation. All Rights Reserved.
EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice.
THE INFORMATION IN THIS PUBLICATION IS PROVIDED "AS IS." EMC CORPORATION
MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO
THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Use, copying, and distribution of any EMC software described in this publication requires an applicable software license.
For the most up-to-date regulatory document for your product line, go to the Technical
Documentation and Advisories section on EMC Powerlink.
For the most up-to-date listing of EMC product names, see EMC Corporation Trademarks on
EMC.com
All other trademarks mentioned herein are the property of their respective owners.
EMC CLARiiON Server Support Products for Linux Servers Installation Guide
53
Download
Advertisement
Key features
Storage system initialization
Host agent installation
Server utility installation
Command line interface installation
Admsnap utility installation
Removing software
Configuring the host agent
Using the event monitor configuration file
Running the host agent
Running the server utility
Frequently asked questions
Table 1 on page 4 lists the minimum FLARE versions required for each storage system and the server software it supports.
Table 3 on page 19 describes the differences between the host agent and server utility.
The latest information is posted on the EMC Powerlink website. You can access it using the link: http://Powerlink.EMC.com