Essick EA1201 Humidifier Owner's Manual

Add to My manuals
8 Pages

advertisement

Essick EA1201 Humidifier Owner's Manual | Manualzz
 MANUAL
&
USE
MODEL:
EA1201 Silver and Black
Touch screen control
Variable Speed Motor
Automatic Humidistat
Automatic Shutoff
Nighttime Setting
SAVE THE ENVIRONMENT
RECYCLE APPROPRIATE MATERIALS
To order parts and accessories call
1-800-547-3888
1872484 4-2013
EVAPORATIVE
HUMIDIFIER
FT IETS LT ры ее: NE
RECTA
French and Spanish
Instructions included.
Se incluyen instrucciones
En Español y Francés.
Directives en Francais et en
espagnol compris
Printed in China
IMPORTANT SAFEGUARDS
General Safety Instructions
READ BEFORE USING YOUR HUMIDIFIER
DANGER: means if the safety information is not followed someone will be
seriously injured or killed.
WARNING: means if the safety information is not followed someone could be
seriously injured or killed.
CAUTION: means if the safety information is not followed someone may be
injured.
1. To reduce the risk of fire or shock hazard, this humidifier has a polarized plug
(one blade is wider than the other.) Plug humidifier directly into a 120V, А.С.
electrical outlet. Do not use extension cords. If the plug does not fully fit
into the outlet, reverse plug. If it still does not fit, contact a qualified electrician
to install the proper outlet. Do not change the plug in any way.
2. Keep the electric cord out of traffic areas. To reduce the risk of fire hazard,
never put the electric cord under rugs, near heat registers, radiators, stoves or
heaters.
3. Always unplug the unit before moving, cleaning or removing the fan assembly
section from the humidifier, or whenever it is not in service.
4. Keep the humidifier clean.
5. Do not put foreign objects inside the humidifier.
6. Do not allow unit to be used as a toy. Close attention is necessary when used
by or near children.
7. To reduce the risk of electrical hazard or damage to humidifier, do not tilt, joit
or tip humidifier while unit is running.
8. To reduce the risk of damage to humidifier, unplug when not in use.
9. To reduce the risk of accidental electrical shock, do not touch the cord or
controls with wet hands.
10. To reduce the risk of fire, do not use near an open flame such as a candle or
other flame source.
WARNING: For your own safety, do not use humidifier if any parts are
damaged or missing.
WARNING: To reduce risk of fire, electric shock, or injury always unplug
before servicing or cleaning.
WARNING: To reduce the risk of fire or shock hazard, do not pour or spill
water into control or motor area. If controls get wet, let them dry completely
and have unit checked by authorized service personnel before plugging in.
INTRODUCTION
Your Essick Air evaporative humidifier adds invisible moisture to your home by
moving dry air through a saturated wick. As air moves through the wick, the
water evaporates into the air, leaving behind any white dust, minerals, or
dissolved and suspended solids. Because the water is evaporated, there is no
messy mist or spray, just clean and invisible moist air.
As the evaporative wick traps accumulated minerals from the water, its ability to
absorb and evaporate water decreases. We recommend changing the wick at
the beginning of every season. In hard water areas, more frequent replacement
may be necessary to maintain your humidifier's efficiency.
Use only Essick Air brand replacement wicks and chemicals. To order parts,
wicks and chemicals call 1-800-547-3888. The EA1201 humidifier uses 3 Wicks
part number HDC311. Only the Essick Air evaporative wick guarantees the
certified output of your humidifier. Use of wicks other than Essick Air brand may
void your warranty as well as the certification of output and may reduce the
efficiency of your humidifier.
ABOUT YOUR HUMIDIFIER
HUMIDIFIED AIR QUT
THROUGH TCP
TOUCH
CONTROL PANEL
— DRY AIR
IN THROUGH
SIDES & BACK
POUR IN
FILL DOOR
> Ш
fl
= )
i
Ñ— A
FEATURES
Output per 24 hrs 12 gallons
Water capacity 3.5 gallons
2500 (avg. construction)
Sg. fi. coverage 3000+ (tight construction)
Fan Speeds Variable (9)
Replacement wicks HDC311
Automatic humidistat Yes
Auto shutoff Yes
Control type Digital Touchscreen
Volts 120
Hertz 60
| Watts 80
NOTE: If excessive condensation forms, reduce set
hiimidity level! 11ntil condensation no lonaer forms
How it Works
Dry air is drawn into the
- unit- through-- the sides
where the air in pulled
through the saturated wicks
and becomes moisturized
before it is fan forced out
the top of the unit to the
room.
Location Tips
Place humidifier in area
that needs most humidity
is needed or where moist
Air will be circulated
throughout house such
as near a cold air return.
DO NOT place unit:
o directly in from of hot
air duct or radiator.
e near thermostat or hot
air register
e next to window
e Up against heavy
drapery of curtains
ASSEMBLY
UNPACKING AND SETTING UP THE UNIT
1. Open the carton and lift out the humidifier.
2. Lift the humidifier chassis (top part) off the base to locate the accessory kit
inside, including:
+ Caster kit
¢ Bacterial freatment sample
WICK
EVAPORATIVE WICKS
5. Three (3) HDC311 wicks
(provided) fit into the wick
frame.
To replace wicks separate the
wick frame top from the wick
frame base and slide wicks
into each of the three
sections. Secure wick frame
top to the base by positioning
the slots on the top onto the
tabs on the base.
Ensure the float is in position,
place the chassis onto the base
and the unit is ready for filling.
CHASSIS
FRAME
ASSEMBLY
+ Evaporative Wicks (3)
+ Manual
CASTERS
3. Remove wick frame and float
assembly from base.
Turn the base upside down.
Insert each caster stem into a
caster hole on each corner of
the humidifier bottom. The
casters should fit snugly and
be inserted until the stem
shoulder reaches the cabinet
surface. Turn the base right
side up. Replace float back in
its place.
4.
SLOT
(6 PLCS)
WICK: 33 Deas WICK
FRAME: RE 19 BAY
BASE,
a8.
{6 PLCS)
i :
Er
FILLING INFORMATION
8. Your humidifier is equipped with a
convenient front pour- in door. Use a
pitcher to fill the unit through the spout FOURIN -
door. When the door is opened an LED FILL DOOR
light illuminates the MAX FILL line
inside. The reservoir holds 3.5 gallons.
Do Not Overfill.
NOTE: Fill unit with cool, fresh {preferably
unsoftened) water. If you only have softened
water available in your home, you can use it,
but mineral buildup will occur more quickly.
NOTE: On initial fill up, it will take approximately 20 minutes for the wick to
become fully saturated.
CONTROLS AND OPERATION
1. Plug cord into wall
receptacle. Your
humidifier is now
ready for use. The
humidifier should not
to be near any heat
registers.
DIGITAL DISPLAY
RG =
HUMIDITY
2. Place the unit at least
FOUR inches away
from any walls.
Unrestricted airflow
| FAN SPEED into the unit will result
SETTINC POWER in the best efficiency
| | and performance.
3. The digital touch screen panel allows you to control the fan speed and humidity
[evel by simply tapping the appropriate up or down arrow switch on the front of the
panel.
4. À digital display provides information on the status of the unit. Depending on which
function is being accessed, it displays ambient and set humidity, fan speed and
status of the unit. |
FAN SPEED
5. Tap the up arrow or down arrow on the FAN SPEED section to adjust the fan.
The display will show F1 through F9 proceeding from low to high speed.
NOTE: When excessive condensation exists, a lower speed setting is recommended.
HUMIDITY CONTROL
NOTE: The EA1201 has an automatic humidistat that cycles the humidifier on and
off as required to maintain the selected setting. |
6. Atinitial startup the ambient humidity of the room will be displayed.
7. Tap the up or down arrow in the HUMIDITY SET section of the panel to
adjust the humidity level in 5% increments. At 65% set point, the unit wil
operate continuously.
INCREASE
FAN SPEED
DECREASE
FAN SPEED
HUMIDITY
HUMIDITY LEVEL
OTHER INDICATIONS
8. When the unit runs out of water the control will display a flashing” F*. When
the unit is completely out of water, the motor will shut off.
9. This humidifier has a check filter reminder timed to appear after 720 hours of
operation. When the Check Filter (CF) message is displayed, disconnect the
power cord and check the condition of the filter. The CF function is reset after
plugging the unit back in.
NIGHTTIME SETTING
10. As a convenience, a nighttime setting switch (Crescent moon} extinguishes all
lights on the control panel but leaves all settings in their current state. Touch
any of the switches to reset the panel to the normal lighting.
CARE AND MAINTENANCE
CAUTION: Disconnect power before filling, cleaning or servicing unit. Keep grille
dry at all times.
Cleaning your humidifier regularly helps eliminate odors and bacterial / fungal
growth. Ordinary household bleach is a good disinfectant and can be used to
wipe out the humidifier base and bottle/reservoir after cleaning. We recommend
cleaning your humidifier at least once every two weeks to maintain optimum
environmental conditions for your home.
We also recommend using Essick Air Bacteriostat Treatment each time you refill
your humidifier to eliminate bacterial growth. Add bacteriostat according to the
instructions on the bottle. Please call 1-800-647-3888 to order Bacteriostat
Treatment reference part number 1970.
1. Turn off unit completely and unplug from outlet.
2. Lift out the water bottles and the power pack.
3. Carry bottles and base to cleaning basin. Lift wick from the base allowing the
water to drain. Rinse wick under fresh water only. Do not use soap,
detergent, or any other cleaners on the wick. Leave in sink fo drain.
REMOVING SCALE
4. Empty the water from the reservoir. Fill reservoir % full with fresh water and
add 8 oz. (1 cup) of white vinegar. Let stand 20 minutes. Then empty
solution.
5. Dampen a soft cloth with white vinegar and wipe out reservoir to remove
scale. Rinse the reservoir thoroughly with fresh water to remove scale and
cleaning solution before disinfecting.
DISINFECTING UNIT
6. Fill reservoir %@ full with water and add 1 teaspoon of bleach to each. Wipe
cabinet and reservoir surfaces with this solution. Let solution stay for 20
minutes, then rinse with water until bleach smell is gone. Dry with clean cloth.
7. Refill unit and re-assemble per ASSEMBLY instructions.
SUMMER STORAGE
1. Clean unit as outlined in Care & Maintenance section.
2. Discard used wick and any water in the reservoir or bottles and allow to dry
thoroughly before storage. Do not store with water inside reservoir or bottles.
3. Do not store unit in an attic or other high-temperature area, as damage will occur.
4. Install new filter at beginning of season.
6
Parts List for EA1201
Replacement Parts Available for Purchase
Item no. | Description Part Number
1 Trim Ring 1B72447
2 Fill Door 1B72450
3 Fill Float 1B72487
4 Wick Frame Top | 1B72444
5 Wicks (3) HDC311
6 Wick Frame Bottom 1872445
7 Float Retainer S98830496C002
8 Float F34829816 -
9 Casters (4) 1B5460070
10 Manual (not shown) 1B72484
ESSICK AIR PRODUCTS
HUMIDIFIER WARRANTY
POLICY
EFFECTIVE APRIL 1, 2013
SALES RECEIPT REQUIRED AS PROOF OF
PURCHASE FOR ALL WARRANTY CLAIMS.
This product is warranted against defects in workmanship and materials as listed below:
One year from the date of sale on factory installed components,
Two years from the date of sale on motor and control.
Thirty (30) days on replacement components.
This warranty does not apply to fitters or wicks which are customer replaceable parts.
. This warranty applies only to the original purchaser of the product when itis purchased from
a reputable retailer/dealer.
This warranty does not apply fo damage from accident, misuse, alierations, unauthorized
repairs, unauthorized use, mishandling, unreasonable use, abuse, including failure to perform
care and maintenance as listed in the owners manual, normal wear and tear, nor where the
connected voltage is more than 5% above the nameplate voltage, nor to the equipment or
products being improperly installed or wired or maintained in violation of this Owners Manual.
Alterations include the substitution of name brand components including, but not limited to
wicks and bacteria treatment.
THIS PRODUCT IS NOT INTENDED FOR COMMERCIAL USE. THIS IS THE SOLE AND
- EXCLUSIVE WARRANTY GIVEN BY MANUFACTURER WITH RESPECT TO THE PRODUCTS [|
AND, TO THE MAXIMUM EXTENT PERMITTED BY LAW, IS IN LIEU OF AND EXCLUDES ALL
OTHER WARRANTIES AND CONDITIONS, EXPRESSED OR IMPLIED, ARISING BY
OPERATION OF LAW OR OTHERWISE. INCLUDING WITHOUT LIMITATION,
MERCHANTABILITY AND/OR FITNESS FOR A PARTICULAR PURPOSE.
No employes, agent, dealer or other person is authorized to give any warranties or conditions
on behalf of the manufacturer. The customer shall be responsible for all costs incurred in the
removal or reinstallation and shipping of the product for repairs
Within the limitations of this warranty, purchaser with inoperative units should contact
customer service @ 800-547-3888 for paperwork and instructions on the return of the unit
for replacement. A copy of the sales receipt is required before authorization to return a
unit for repair is approved. The manufacturer will replace the chassis, at its discretion, with
return freight paid by the manufacturer and that TO THE MAXIMUM EXTENT PERMITTED BY
LAW, THE MANUFACTURER IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND,
INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGE OR LOSS OF PROFITS OR
REVENUES.
This warranty will be null & void if purchaser attempts to repair or replace any parts