Trane PTEF, PTHF Packaged Terminal Air Conditioner Installation, Operation, and Maintenance
PDF
Dokument
Annonce
Annonce
Installation, Operation, and Maintenance ProSpace™ Packaged Terminal Air Conditioner (PTAC) Models PTEF and PTHF S A F E T Y WA R N I N G Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. November 2015 PTAC-SVX002A-EN industry replacements for CFCs such as HCFCs and HFCs. Introduction The ProSpace™ Packaged Terminal Air Conditioners and heat pumps provide a high standard of quality in performance, workmanship, durability and appearance as they heat and cool the occupied air space year round. This manual provides information for ease of installation, operation and maintenance. All models are designed for through–the–wall installation. Separate installation instructions are included with all accessory components. General Information Read this manual completely and carefully before starting any work. Write down the model and serial number on the space provided on the product registration card. The model and serial number can be located on the serial number plate attached to the unit. These numbers are required for any service work. I m p o rt a n t : Ensure that this manual is left with the owner for future reference. Observe all local codes and ordinances. Warnings, Cautions, and Notices Safety advisories appear throughout this manual as required. Your personal safety and the proper operation of this machine depend upon the strict observance of these precautions. Important Responsible Refrigerant Practices Trane believes that responsible refrigerant practices are important to the environment, our customers, and the air conditioning industry. All technicians who handle refrigerants must be certified. The Federal Clean Air Act (Section 608) sets forth the requirements for handling, reclaiming, recovering and recycling of certain refrigerants and the equipment that is used in these service procedures. In addition, some states or municipalities may have additional requirements that must also be adhered to for responsible management of refrigerants. Know the applicable laws and follow them. WA R N I N G Prope r Fi el d Wi ring a nd Groundi ng Required! Fa il u re to f ol lo w c ode c o ul d r es u lt i n de at h or s e r i o u s i n j u r y. All field w ir in g MUST be p er for med b y qualif ied per sonnel. Improperly installed and grounded field wiring poses FIRE and ELECTROCUTION h a z a r d s . To a v o i d t h e s e h a z a r d s , y o u M U S T f o l l o w requirements for field wiring installation and grounding as described in NEC and your local/ state electrical codes. The three types of advisories are defined as follows: WARNING CAUTION NOTICE Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. It could also be used to alert against unsafe practices. Indicates a situation that could result in equipment or property-damage only accidents. Important Environmental Concerns Scientific research has shown that certain man-made chemicals can affect the earth’s naturally occurring stratospheric ozone layer when released to the atmosphere. In particular, several of the identified chemicals that may affect the ozone layer are refrigerants that contain Chlorine, Fluorine and Carbon (CFCs) and those containing Hydrogen, Chlorine, Fluorine and Carbon (HCFCs). Not all refrigerants containing these compounds have the same potential impact to the environment. Trane advocates the responsible handling of all refrigerants-including ©2015 Trane All rights reserved PTAC-SVX002A-EN WA R N I N G Pe r s o n a l P r o t e c t i v e E q u i p m e n t ( P P E ) Re q u i r e d! Fai l ure t o we a r p rop er PP E for th e jo b be in g u n d e rt a k e n c o u l d r e s u l t i n d e a t h o r s e r i o u s i n j u r y. Te ch n i c i a n s , i n o r d e r t o p r o t e c t t h e m s e l v e s f r o m p o t e n t i a l e l e c t r i c a l , m e ch a n i c a l , a n d ch e m i c a l h a z a r d s , M U ST f o l l o w p r e c a u t i o n s i n t h i s m a n u a l a n d o n t h e t a g s , s t i ck e r s , a n d l a b e l s , a s w e l l a s t h e instructions below: • • • Before installing/servicing this unit, t e ch n i c i a n s M U S T p u t o n a l l P P E r e q u i r e d f o r t h e w o r k b e i n g u n d e rt a k e n ( E x a m p l e s ; c u t r e s i s t a n t g l ov e s / s l e e v e s , b u t y l g l ov e s , s a f e t y glasses, hard hat/bump cap, fall protection, electrical PPE and arc flash clothing). A LWAY S r e f e r t o a p p r o p r i a t e M a t e r i a l S a f e t y D a t a S h e e t s ( M S D S ) / Sa f e t y D a t a S h e e t s (SDS) and OSHA guidelines for proper PPE. When working with or around hazardous ch e m i c a l s , A LWAY S r e f e r t o t h e a p p r o p r i a t e MSDS/SDS and OSHA/GHS (Global Harmon ized Syst em of Classificat io n an d Labelling of Chemicals) guidelines for i nf orma ti on on a l lo wab le p er s on a l ex po s ure levels, proper respiratory protection and handling instructions. I f t h e r e i s a r is k o f en er g i ze d el e ct r i ca l c o n t a c t , a r c , o r f l a s h , t e ch n i c i a n s M U S T p u t o n a l l P P E i n a c c o r d a n c e w i t h O S H A , N F PA 7 0 E , o r o t h e r c o u n t r y- s p e c i f i c r e q u i r e m e n t s for arc flash protection, PRIOR to servicing the unit. NEVER PERFORM ANY SWITCHING, D I S C O N N E C T I N G , O R VO LTA G E T E S T I N G WITHOUT PROPER ELECTRICAL PPE AND A R C F L A S H C LO T H I N G . E N S U R E E L E C T R I C A L M E T E R S A N D E QU I P M E NT A R E P R O P E R LY R AT E D F O R I NT E N D E D VO LTA G E . • Do not start or stop the air conditioner by unplugging the power cord or turning off the power at the electrical box. • Do not cut or damage the power cord. • If the power cord is damaged it should only be replaced by an authorized Trane service representative. • In the event of a malfunction (sparks, burning smell, etc.) immediately stop the operation, disconnect the power cord, and call an authorized Trane service representative. • Do not operate the air conditioners with wet hands. • Do not pull on the power cord. • Do not drink any water that is drained from the air conditioners. CAUTION! Avoid Injury or Damage to the Unit or Other Property • Provide occasional ventilation during use. Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups or make units run excessively. • Do not place containers containing water on unit. • Turn off the air conditioner at the power source when it will not be used for an extended period of time. • Periodically check the condition of the unit's installation base for any damage. • Do not apply heavy pressure to the radiator fins of the units. • Operate the unit with air filters in place. • Do not block or cover the intake grille, discharge area and outlet ports. • Ensure that any electrical/electronic equipment is one yard away from the unit. • Do not use or store flammable gases near the unit. Safety Precautions WARNINGS! Installation Before installing and operating the Trane ProSpace unit, observe the following safety precautions. • Carefully read the installation section before beginning. • Follow all manual content as shown. • Observe all local, state, and national electrical codes. • Use qualified, licensed personnel during installation and setup. • Observe all Cautions, Warnings, and Notices provided in this manual. DANGER! Avoid Serious Injury or Death • Do not attempt to install air conditioner by yourself. • This air conditioner contains no user-serviceable parts. Always call an authorized Trane service representative for repairs. • When moving the air conditioner, always call an authorized Trane service representative for disconnection and re-installation. • Do not insert or place fingers or objects into the air discharge area in the unit. PTAC-SVX002A-EN Copyright This document and the information in it are the property of Trane, and may not be used or reproduced in whole or in part without written permission. Trane 3 reserves the right to revise this publication at any time, and to make changes to its content without obligation to notify any person of such revision or change. 4 Trademarks All trademarks referenced in this document are the trademarks of their respective owners. PTAC-SVX002A-EN Table of Contents Model Number Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Unit Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Intelligence. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Memory. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Quiet Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Random Compressor Restart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Compressor Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Automatic Room Freeze Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Automatic Quick Warm-Up (Heat Pump Models Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Dual–8 display and LED Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Fan Configuration Optimization for Selected Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Other Unit Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Electrical. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Power Connection Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 All Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Grounding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Voltage Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Cord/Connected Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Power Cord Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Trane Wall Sleeve and Grille . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Considerations for Use of Existing Sleeves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Installing the Chassis Into Wall Sleeve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Adjusting Air Direction- Only for Duct Installations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Dip Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Keypad Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Auxillary Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Wiring the Wall Thermostat. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Energy Management Input (Front Desk Control) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Intelligent Self-Checking Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Control Buttons and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Operating the Remote Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Care and Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 PTAC-SVX002A-EN 5 Ta b l e o f C o n t e n t s Front Panel and Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Outdoor Coil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Base Pan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 6 PTAC-SVX002A-EN Model Number Description Use the following to determine the correct model number. P T E F 070 2 G AA Digit 1,2 Digit 3 Digit 4 Digit 5-7 Digit 8 Digit 9 Digit 10,11 • Di gi t 1 , 2 ; Produ c t Fam i l y – • • Digit 3; Heating M ethods – E = Cooling with Electric Heat – H = Heat Pump with Electric Heat Digit 4; Development Seq uence – • • • • PTAC-SVX002A-EN PT = Packaged Terminal Unit F Di g i t 5 t h r o u g h 7 ; S i ze a n d C o o l i n g – 070 = 7,000 Btu – 090 = 9,000 Btu – 120 = 12,000 Btu – 150 = 15,000 Btu Digit 8; Electrical Voltage – 1 = 208/230 Vac – 2 = 265 Vac Di g i t 9 ; E l e ct r i c H e at S i ze – G = Maximum of 3.5 kW – H = Maximum of 5.0 kW D i g i t 10 , 11 ; D e s i g n S e q u e n c e – AA = First – AB = Second 7 Unit Features This unit has many features that are different from those found on standard PTAC models. The owner should become familiar with these features in order to fully understand the operation and capabilities of the unit: Intelligence The unit has an on board computer which utilizes real-time diagnostics to prolong the life of the unit. There is an LED indicator on the control board, behind the front panel, that flashes an error code if the unit detects a faulty condition. In many situations, the unit automatically clears the fault condition and continues operating with no interruption. However, In some cases, the condition cannot be cleared and the unit will require servicing. In those situations, an F x failure mode displays on the digital display. N o t e : Refer to the diagnostic codes in the section,“Intelligent Self-Checking Control,” p. 23. Memory In the event there is a power lost, all of the control settings (Setpoint, Mode, Fan Speed, ON/OFF and Configuration) are retained in memory. After power is restored, the unit starts back up in the previous mode (and configuration) prior to a power loss. Quiet Design The ProSpace has two (2) fan motors and a tangential blower wheel for optimum quietness. The indoor fan always runs, at a minimum of 10 seconds, before the compressor in order to reduce the sound of the compressor starting. Random Compressor Restart The compressor is equipped with a 2–minute, 45 second to 3–minute 15 second random restart delay feature. This helps to prevent power surges after a power outage (for example, when many PTACs start at the same time). Whenever the unit is plugged in, or when power has been restarted, a random compressor restart occurs to help avoid power surges. Compressor Protection The ProSpace has a random start-up delay of three (3) minutes on the compressor, with a minimum compressor run time of three (3) minutes, to prevent short cycling of the compressor and to maximize its life. Automatic Room Freeze Protection This protection feature automatically ensures the indoor temperature does not fall below freezing. When the PTAC is configured for freeze protection (the default condition), the power is supplied to the unit, and if the unit senses a temperature below 40°F, the fan motor and electric heater turn ON and warms the room to 50°F (10°C). The unit can be configured to have freeze protection turned OFF. Automatic Quick Warm-Up (Heat Pump Models Only) If the room temperature falls to 5°F (-15°C) below the setpoint temperature, the reverse cycle heat is shut OFF and the electric strip heat is turned ON for one (1) cycle, until room temperature rises. 8 PTAC-SVX002A-EN U n i t Fe a t u r e s Dual–8 display and LED Display The ProSpace has two (2) 8-segment nixie tubes and the following 13 LED indicators: • High • Med • Low • Auto • Cool • Fan • Heat • On • Off • Setpoint • Indoor • Status • Timer • M o d e I n d i c a t o r D i s p l a y : when the air conditioner operates in a certain mode, the corresponding mode indicator is lit. • O N / O F F I n d i c a t o r : displays in green when the controller is ON and red when controller is OFF. • F a n S p e e d D i s p l a y : when the air conditioner operates at HIGH, MED, LOW, or AUTO fan speed, the corresponding indicator is lit. • D u a l - 8 D i s p l a y : ambient temperature can be displayed in cooling and heating modes by changing settings using the keypad. Displays N o t e : Under cooling or heating mode, the Dual-8 displays the set temperature and (the Dual-8 displays indoor ambient temperature under fan mode. • D i s p l a y D a t a w i t h 3 – b i t s : the Dual-8 displays a ten digit + the unit digit at first and then displays BLANK + hundred digit. Fan Configuration Optimization for Selected Application The unit can be optimized for selected applications by configuring the fan to run in Continuous mode or cycle ON/OFF with the compressor and electric heater (can be different for both heating and cooling modes). In cycle mode, the fan continues to run after the compressor or electric heater stops in order to blow off any residual heat or cool left on coil. Other Unit Configurations PTAC-SVX002A-EN • Display either Fahrenheit (F°) or Celsius (C°). • Optimize the room temperature sensor reading to the exact application— one for cooling, one for drying, and one for heating (indoor temperature sensor biasing). • Emergency Heat (for Heat Pump Only); disable the compressor during heating mode operation (heat only with Electric Heat). • Configure the unit to display only the room temperature or setpoint during heating and cooling modes. • Configure the unit to limit the controlling setpoint range. The display always shows the complete setpoint range, but the controlling setpoint is limited to the configured minimum/ maximum setpoint selected. 9 Unit Fe at ur es 10 • Energy Management (also referred to as Front Desk Control); an input is provided so that the unit can be manually disabled from a different location. If the unit detects 24 Vac on this input, it automatically turns itself OFF. If no voltage is detected on the input, the unit runs normally. • Wall Thermostat Control; a wired wall thermostat can be connected to the unit. If so, the unit must be configured to disable the keypad. PTAC-SVX002A-EN Electrical WA R N I N G Li ve Electrical Components! Fa il ur e to f ol lo w a ll el e ct ri ca l s a fe ty p re ca ut i ons whe n e xp os ed t o li ve e l ec t ri ca l c o m p o n e n t s c o u l d r e s u l t i n d e a t h o r s e r i o u s i n j u r y. When it is necessary to work with li ve electrical components, have a qualified licensed electrician or other indi vidual who has been properly trained in handling li ve electrical components perform these tasks. Power Connection Options Appropriate power cord accessory kit is determined by the voltage and the amperage of the branch circuit, based on the unit amperage requirements (for example, electric heater size). The unit ships without a power cord. N o t e : Ensure the outlet matches the appropriate prong configuration on the plug. It should be within reach of the service cord. All wiring, including installation of the receptacle, must be in accordance with the NEC™ and all local codes, ordinances and regulations. National codes require the use of an arc fault or leakage current detection device on all 208/230V power cords. For 265V units, if power cord accessory option is selected, then the cord is only l8" long and must plug into the accessory electrical 265V sub-base. All Units I m p o rt a n t : Follow NEC and local electrical codes when installing electrical supply wiring. The following is only shown as a sample. Use recommended wire size (Table 1) and install a single-branch circuit. All units are designed to operate off only one (1) single branch circuit. N o t e : Only use copper conductors. Branch circuit wire is single circuit from main box. AWG wire sizes are based on copper wire at a 140°F (60°C) temperature rating. Table 1. Common Branch Circuit Wire Sizes Nameplate Amps AWG Wire Size 7.0 to 12 14 12.1 to 16 12 16.1 to 24 10 Grounding For safety and protection, the unit is grounded through the service cord plug or through separate ground wire provided on hard wired units. Ensure that the branch circuit or general purpose outlet is grounded. PTAC-SVX002A-EN 11 Electrical Voltage Supply Check voltage supply at outlet. For satisfactory results, the voltage range must always be within the ranges specified on the data information plate. Power cord does not ship with the unit. The cord to order is determined by the unit voltage and the desired electric heat capacity. Cord/Connected Units The 250 Vac field supplied outlet must match the plug for standard 208/230V units and be within reach of the service cord. N o t e : Do NOT use 30 amp cord with size 07 units. Table 2. Electric Heater and Cord Information, PTEF07xxx and PTHF07xxx Voltage 230 Vac Amps Heater Size Plug Layout 265 Vac 15 20 15 20 2.5 kW 3.5 kW 2.5 kW 3.5 kW G G G G W NEMA Plug Cord # W 6-15P 6-20P 7-15P 7-20P PWR00286 PWR00288 PWR00287 PWR00289 Table 3. Electric Heater and Cord Information, PTEF and PTHF Size 09, 12, and 15 Voltage Amps Heater Size Plug Layout 230 Vac 265 Vac 15 20 30 15 20 30 2.5 kW 3.5 kW 5.0 kW 2.5 kW 3.5 kW 5.0 kW G G G G W NEMA Plug Cord # G G W W 6-15P 6-20P 6-30P 7-15P 7-20P 7-30P PWR00286 PWR00288 PWR00290 PWR00287 PWR00289 PWR00291 Power Cord Protection N o t e : Power cord does not ship with the unit. The power cord for 230/208V units provide protection from fire. The unit power automatically disconnects when unsafe conditions are detected. Power to the unit can be restored by pressing the reset button on plug head. Upon completion of unit installation for 230/208V models, an operational check should be performed using the TEST/RESET buttons on the plug head. N o t e : Models with 265V do not incorporate this feature because they require use of an electrical sub-base accessory. Connection to a wall socket is not permitted for 265V units. All 265V units must be hard wired using the hard wire kit or make use of the plug-in receptacle in the standard sub-base. 12 PTAC-SVX002A-EN Installation Trane Wall Sleeve and Grille The image below shows the typical unit components that are ordered and installed. I m p o rt a n t : Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under warranty. To install the Trane Wall Sleeve and Grille, refer to the latest installation instructions, PTAC-SVN028 and PTAC-SVN027. Considerations for Use of Existing Sleeves I m p o rt a n t : For retrofit applications, foam seals on outdoor coil tube sheets must make a seal between the coil and the grill or loss of performance and premature damage to the major components can result. WA R N I N G Li ve Electrical Components! Fa il ur e to f ol lo w a ll el e ct ri ca l s a fe ty p re ca ut i ons whe n e xp os ed t o li ve e l ec t ri ca l c o m p o n e n t s c o u l d r e s u l t i n d e a t h o r s e r i o u s i n j u r y. When it is necessary to work with li ve electrical components, have a qualified licensed electrician or other indi vidual who has been properly trained in handling li ve electrical components perform these tasks. In applications when the unit is a replacement, it is recommended to use a Trane sleeve. This unit can be retrofitted to other manufacturers similar sleeves if outdoor unit airflow is not restricted or recirculated. N o t e : Ensure the outdoor grille is installed on the sleeve. For any sleeve retrofit applications, be sure that the foam seals (factory installed on the tube sheets) provide a good seal between the grille and outdoor coil tube sheets. These foam seals provide a barrier that stops the inside air from mixing with the outside air (known as air recirculation). PTAC-SVX002A-EN 13 Installation I m p o rt a n t : Inspect the wall sleeve thoroughly prior to installation. The manufacturer does not assume responsibility for costs or damage due to defects in the sleeve or for improper installation. Remove any existing foam baffles installed on competitor’s outdoor grille. General Electric Metal Wall Sleeve; interchangeable with ProSpace wall sleeve. General Electric Plastic Wall Sleeve; remove bottom seal from plastic sleeve. 14 PTAC-SVX002A-EN Installation Installing the Chassis Into Wall Sleeve N OT I C E Equipment Damage! Use spreader bar s to prevent straps from damaging the unit. Install the bars between l i ft i n g s t r a p s , b o t h u n d e r n e a t h t h e u n i t a n d a b ov e t h e u n i t t o p r e v e n t t h e s t r a p s f r o m crushing the unit cabinet or damaging the finish. 1. Carefully remove shipping tape from the front panel and vent door. 2. Remove shipping screw from the vent door, if present. 3. Remove front panel. Consider the following electrical guideline before sliding the unit back into the wall. • PTAC-SVX002A-EN All units require a cord or a hard-wired kit to be added to complete electrical connection to the building. Follow the instructions provided with those accessories. 15 Installation 16 4. Lift unit level and slide unit into wall sleeve until foam seal rests firmly against front of wall sleeve. 5. Secure with four screws (supplied) through the unit flange holes. 6. Re-install front panel by first, hooking tabs over top rail of unit and then pushing in on the bottom of the front panel until it snaps into place. PTAC-SVX002A-EN System Configuration Adjusting Air Direction- Only for Duct Installations PTAC-SVX002A-EN 1. Remove front panel. 2. Remove louver screws that hold the louver insert in place on the back side of the front panel. 3. Turn louver insert and rotate it 180°. 4. Replace louver insert. 5. Replace screws and the front panel. 17 Sys t em C o n f i g u r a ti o n Dip Switches The auxiliary dip switch controls are located behind the front panel and through an opening below the control panel. To access, you must remove the front panel. The dip switches are accessible without opening the control box, but the unit must be powered OFF to effectively change functions. N o t e : Factory settings for dip switches will be in the DOWN position. Refer to the following for the functionality of each dip switch position. 1 2 3 4 5 6 7 Freeze Guard Setpoint Limit 2 Setpoint Limit 1 Fan CON/CYC for Cooling/ Energy Saver: Cooling Fan CON/CYC for Heating Energy Saver: Heating Wall Thermostat Enable Electric Heat Only for Heat Pumps Table 4. Dip Switch Descriptions 18 Dip Switch Number Up Down Default Remarks 1: Electric Heating Only/Emergency Heat. This setting is typically used for Emergency Heating. Electric Heat Only Heat Pump Down For only heat pump units. 2: Wall Thermostat Enable. A wired wall thermostat can be connected to the unit. The dip switch must be adjusted accordingly in order to allow the wall thermostat control of the unit. When unit is in wall thermostat mode, the control panel is disabled. Wall Thermostat Enable Control Panel Enable Down 3: Energy Saver Dip Switches. Allows the fan to operate in continuous or cycle mode while the unit is in heating or cooling mode. Dip Switch 3: Continuous and allows the fan to run continuously, circulating air even when the temperature setting has been satisfied. Dip Switch Fan Continuous Run for Heating. Fan Cycle for Heat Down 4: Energy Saver Dip Switches. Allows the fan to cycle ON and OFF with the compressor or electric heater. The fan stops a short time after the temperature setting is satisfied. This is the most efficient mode for electrical usage. Fan Cycle for Cool. Fan Continuous Run for Cooling Down PTAC-SVX002A-EN System Configuration Table 4. Dip Switch Descriptions (continued) Dip Switch Number Up 5/6: Setpoint Temperature Limits. Provides a range of temperature control. Up/Up 68°F to 75°F (20°C to 24°C) 7: Room Freeze Protection. If the unit senses a room temperature below 40°F (4.44°C), the fan motor and electric strip heat turns ON and warms the room to 50°F (10°C). The fan stops a short time after the temperature is satisfied. Freeze Guard Disable Down Up/ Down 63°F to 80°F (18°C to 28°C) Down/ Up 65°F to 78°F (19°C to 26°C) Down/ Down 61°F to 86°F (16°C to 30°C) Freeze Guard Enable Default Remarks Up/Up 61°F to 86°F (16°C to 30°C) Config. 5 and 6 combine to select set point range. When setpoint limit set, display always shows full range. Down Keypad Configuration The Trane ProSpace can be customized by configuring the keypad. 1. To enter the keypad configuration screen, first power up the unit. 2. Within the 30 seconds after power-up press and hold both the f a n s p e e d + (5) seconds. buttons for five N o t e : If waiting more than 30 seconds after power-up, you cannot access the keypad configuration. Power down and power up the unit again to restart the process. 3. To scroll through the available options, press and release the f a n s p e e d button to select the keypad configurations. The stored value displays. 4. To exit the configuration screen, press the m o d e button or after 30 seconds, the unit will automatically exit the configuration screen. 5. To modify configuration settings, press and release simultaneously, either the Se t p o i n t + or Se t p o i n t + buttons. Choose from the following four (4) options: PTAC-SVX002A-EN • F a h r e n h e i t / C e l s i u s D i s p l a y S w i t ch ; changes between degrees Fahrenheit (F, default) and Celsius (C) on the display. • I n d o o r A i r Te m p e r a t u r e S e n s o r B i a s i n g f o r C o o l i n g M o d e ; adjusts the room air temperature reading when in cooling mode (not normally required). • I n d o o r A i r Te m p e r a t u r e S e n s o r B i a s i n g f o r H e a t i n g M o d e ; adjusts the room air temperature reading when in heating mode (not normally required). • I n d o o r Te m p e r a t u r e D i s p l a y ; changes between showing the setpoint or desired temperature during heating and cooling modes (SP, default) or displaying the actual room temperature during heating and cooling modes (AA). – Selecting SP displays the desired setpoint temperature during heating and cooling modes, regardless of what the actual temperature is in the room . – Selecting AA displays the room temperature during heating, cooling, and fan-only modes – Changing the mode button to either heating or cooling modes displays the setpoint for 10 seconds. After the 10 seconds, the room temperature displays. – Depressing the ON-OFF when the unit is OFF, and the last mode was either cooling or heating, the setpoint displays for 10 seconds before displaying the room temperature. – Depressing either or during heating and cooling mode displays the setpoint for 10 19 Sys t em C o n f i g u r a ti o n seconds before displaying the room temperature. 6. Press or to switch between E m e r g e n c y A u t o C o o l i n g A l l o w e d (displays as CA) and E m e r g e n c y A u t o C o o l i n g R e j e c t e d (displays as CD). 7. 20 When activating Auto Cooling Operation and room temperature reaches 85°F while the unit is in the S TO P mode, the unit automatically starts in Air Conditioning Operation and shuts off when the room temperature reaches 80°F. PTAC-SVX002A-EN Auxillary Controls Wiring the Wall Thermostat WA R N I N G Li ve Electrical Components! Fa il ur e to f ol lo w a ll el e ct ri ca l s a fe ty p re ca ut i ons whe n e xp os ed t o li ve e l ec t ri ca l c o m p o n e n t s c o u l d r e s u l t i n d e a t h o r s e r i o u s i n j u r y. When it is necessary to work with li ve electrical components, have a qualified licensed electrician or other indi vidual who has been properly trained in handling li ve electrical components perform these tasks. N OT I C E Equipment Damage! Fa il ur e to f ol lo w in st ruc t io ns w i ll r es ul t i n pre m a tur e fa il u re of th e un it . I m p r o p e r w i r i n g m a y d a m a g e u n i t e l e c t r o n i c s . C o m m o n b u s i n g i s n o t p e r m i tt e d . D a m a g e o r e rr a t i c o p e r a t i o n m a y r e s u l t . To wire the to the thermostat: 1. Check to be sure power to unit is disconnected. 2. Route the wire through the thermostat under the sleeve and behind the front panel as shown below. PTAC-SVX002A-EN 21 Auxillary Controls 3. Remove the terminal connector to simplify wiring. 4. Connect wires from the thermostat to terminals on unit terminal connector. N o t e : Thermostat wire is field supplied. Recommended wire gauge is 18 to 20 gauge, solid thermostat wire. Energy Management (24 Vac) Common R W Y O GH GL C • R; 24 Vac • W; Electric Heat • Y; Compressor • O; Reversing Valve (Heat Pump Connection Only) • GH; High Fan • GL; Low Fan • C; Common (Typically for Digital Thermostats) N o t e : Any incorrect input combinations are captured as thermostat wiring failures and will light the STATUS LED indicator on main board. 5. Reinstall terminal connector. 6. Ensure that unit is configured for wall thermostat enable. 7. Replace control panel label with control panel guard. 8. Power-up the unit. General Notes: • Anytime there is a second-stage call for heating from the wall thermostat,, the unit automatically switches over to electric heating for heat pump models. • For thermostats with two (2) fan speed output (such as Low fan or Hi fan), the fan speed is determined by how the terminal connector is wired. When using Low fan speed, wire the GL output from the thermostat to GL on the terminal block. When using Hi fan speed, wire the GH output from the thermostat to GH on the terminal block. . 22 PTAC-SVX002A-EN Auxillary Controls Energy Management Input (Front Desk Control) The controller can handle a switch signal from remote energy management input, called an EM signal or front desk control. The input must be 24 Vac. When the system receives a 24 Vac signal, it turns OFF the unit; otherwise it is in normal control. This function is disabled under Freeze Guard protection. Intelligent Self-Checking Control The. PTAC has an on-board computer continuously checks key components of the unit to ensure they are operating properly. Under normal operation, the unit status indicator (STATUS, on main PCB), light is steadily ON. If there is a major problem, the unit shuts down and displays a diagnostic failure code on the control. If it is a minor error and the unit can correct it by itself, the diagnostic code is flashed on the status LED that is easily seen when the front panel is removed. Refer to the following table of diagnostic codes. Table 5. Diagnostic Codes Diagnostic Code Code Description Explanation 1 Indoor air temp sensor open or short. An 8-segment display Fl, STATUS light flashes once an then OFF 3 seconds, repeat.(a) 2 Indoor coil sensor open or short. An 8-segment display F2, STATUS light flashes 2 times and then OFF 3 seconds, repeat. 3 Outdoor coil sensor open or short. An 8-segment display F4, STATUS light flashes 3 times and then OFF 3 seconds, repeat. 4 Freeze guard protection. An 8-segment display FP. 5 Indoor coil freeze protection. The STATUS light flashes 5 times and then OFF 3 seconds, repeat. 6 Outdoor coil high temp protection. The STATUS light flashes 6 times and then OFF 3 seconds, repeat. 7 Defrost (heat pump type). The STATUS light flashes 7 times and then OFF 3 seconds, repeat. 8 Indoor coil high temp protection. The STATUS light flashes 8 times and then OFF 3 seconds, repeat. 9 Thermostat wiring error. The STATUS light flashes 9 times and then OFF 3 seconds, repeat. (a) PTAC-SVX002A-EN When the status light is flashing, it is ON 1 second and then OFF 1 second. 23 Operation The following sections describe the operation of the Trane ProSpace unit. Control Buttons and Functions The section describes the buttons and functionality of the Trane ProSpace unit. • O N / O F F ; turns the unit ON or OFF. • M o d e ; switches between Cool, Fan, Heat, or Dry (optional). Pressing this button when in OFF mode and the controller resumes to the operation status before power-off. • WA R M E R o r C O O L E R ; the dual–8 nixie tube displays the indoor temperature for 15 seconds and then turns OFF. It is used to increase/decrease the temperature or timer setting. • F a n ; sets the High, Medium, Low or Auto fan speeds. • T i m e r ; sets the timer function by using either of the buttons on the control panel or by the remote controller. – T i m e r O N f u n c t i o n ; the timer can be set to ON when the unit is OFF. Setting range is between O.5 hours to 24 hours. When timer ON setting is reached, the system stops and operates according to the set mode. – T i m e r O F F f u n c t i o n ; When the unit is off, timer OFF can be set. Setting range is between O.5 hours, to 24 hours. When timer OFF setting is reached, the system stops operation. – T i m e r P r e v i e w f u n c t i o n : use this function to preview the remaining time of timer. • S l e e p f u n c t i o n ; can only be set only using the remote controller. • D r y f u n c t i o n ; the air conditioner can dehumidify and make the room air dry and comfortable. • B u z z e r o p t i o n ; when the controller is energized, or when a valid remote control signal or /button signal is received, the buzzer beeps. • A u t o F a n S p e e d f u n c t i o n ; can be automatically selected according to different modes or indoor temperature to achieve a higher comfort level. • E m e r g e n c y C o o l i n g O p e r a t i o n f u n c t i o n ; When the indoor ambient temperature is 86°F (30°C), the unit starts cooling automatically. When the indoor ambient reaches 80.6°F (27°C), the unit stops operation. • F- c o d e Re m o t e C o n t r o l l e r f u n c t i o n ; optional. Operating the Remote Control The optional ProSpace remote control has many of the features that are accessible through the ProSpace front panel. Ensure that there are no obstructions between the receiver and the remote controller. I m p o rt a n t : Do not drop or throw the remote control. Do not spill any liquids in the remote control. Do not put the remote control directly into the sunlight or near hot surfaces. 24 PTAC-SVX002A-EN Operation ON AUTO COOL DRY FAN HEAT OFF °F OPER °C AUTO .5H SWING SLEEP LOCK SPEED ON / OFF MODE FAN SWING SLEEP TIMER • O N / O F F ; press to turn O N the unit and press again to turn O F F the unit. When turning ON / OFF the unit, the T i m e r and S l e e p functions are cancelled, but the pre-setting time is retained. • M O D E ; press to cycle through the mode selections in the following order: Cool to Dry to Fan to Heat. In Heat mode, the initial value is 82°F (28°C) and in other modes, the initial value is 77°F (25°C). N o t e : Heat Mode is only for cooling/heating units. If in Cooling Mode, there is no action taken when the unit receives a call for heating. B l o w- o v e r h e a t : when the unit is running in Heat Mode or Auto Heat Mode, the compressor and indoor fan running, to turn the unit off, the compressor, outdoor fan will stop running. The upper and lower guide boards rotate to a horizontal position, the indoor fan run at LOW FAN speed, and the 10 seconds later, the unit turns OFF. • FA N ; press to cycle through the fan speed selection in the following order: AUTO to FAN 1 to FAN 2. The speeds are represented on the remote as vertical bars increasing in size for each speed. When initializing the fan, the AUTO setting is default. N o t e : Only LOW Fan Mode can be selected in DRY mode. Pressing this key can not adjust the fan speed, but can send message to the unit. PTAC-SVX002A-EN • S L E E P ; Press to select SLEEP ON/OFF. When powering the unit, the SLEEP OFF setting is default. After setup is complete, the signal for SLEEP Mode displays on the unit. While in SLEEP Mode, the TIMER setting can be adjusted. SLEEP Mode is not available in FAN and AUTO Modes. Once the unit is turned OFF, the SLEEP Mode is cancelled. • S W I N G ; not used. • T I M E R ; in SWITCH OFF state, press this key to set the time for AUTO SWITCH ON state. The range of setting is between O.5 hours to 24 hours. The characters T-ON and H flash for 5 seconds and within this 5–second flash, press this key once to complete the setting and send the message to the unit. If this setting is valid, the set time displays for 2 seconds before displaying the temperature message. During the 5–second flash, press + key to increase the time value and - to decrease the value. The values increase/decrease in increments of 0.5 hours with each press of the key. Pressing this key in rapid successions to increase/decrease the values will advance the increments quickly. The remote controller can increase the set time by 0.5 hours every 0.25 seconds. After energizing the unit, the default is NO TIMER 25 Operation setting and the T-ON or H characters do not display. When the temperature display becomes constant, press this key again to display the remaining set time. The time values, T-ON and H, display constantly for 2 seconds. After 2 seconds, the preset temperature displays. Within these 2 seconds, press this key again to CANCEL the AUTO SWITCH ON and send the message. Pressing this key in SWITCH ON state allows the time to be set to AUTO SWITCH OFF. Press ON/OFF key to switch on the unit and CANCEL the AUTO SWITCH ON state. N o t e : The +/- buttons are used to increase/decrease value settings for either time or temperature. Refer to the sub-sections below about how to use the +/- buttons to set temperature values. – + B u tt o n ; press this button to set increased temperature values when unit is ON. Continuously press and hold this button for more than 2 seconds until °F (°C) displays. In AUTO Mode, the temperature can not be set up, but this button can send the signal. Temperature ranges are between 61°F and 86°F (16°C and 30°C). N o t e : To switch between Fahrenheit and Celsius, press and hold the - a n d M O D E keys simultaneously while in S W I T C H O F F state. – • - B u tt o n ; .press this button to set decreased temperature values when unit is ON. Continuously press and hold this button for two seconds to decrease the temperature value. The temperature adjustment is unavailable in AUTO Mode, but this button can send the signal. LO C K ; to LOCK and UNLOCK (default) the keypad, press and hold the - o r + a n d M O D E keys simultaneously while in either S W I T C H O N S W I T C H O F F states. The unit show the LOCK icon when in LOCK Mode, in which case, the lock icon flashes three (3) times upon operation of any key. The LOCK icon does not display when the unit is in UNLOCK Mode. Changing Batteries in the Remote Control The remote requires two (2) AAA, 1.5V batteries. 1. From the back side of the remote, gently press down on the battery cover and slide it towards the bottom of the unit. 2. Remove the old batteries from the battery compartment. 3. Insert two (2) new batteries into the battery compartment. Ensure the batteries poles match the polarity when inserting them into the battery compartment: + to + and - to -. N o t e : Only use the recommended battery type. If the remote has not been used for an extended period of time, check the expiration date on the batteries or check for battery leakage. 4. Slide the battery cover back onto the remote until the tab clicks. B E ST P R AC T I C E : Check your local city/state for proper recycling procedures. A battery is an electrochemical device with the ability to convert chemical energy to electrical energy to provide power to electronic devices. Batteries contain heavy metals such as mercury, lead, cadmium, and nickel, which can contaminate the environment when batteries are improperly disposed of. When incinerated, certain metals might be released into the air or can concentrate in the ash produced by the combustion process. Batteries may produce the following potential problems or hazards: • 26 Pollute the lakes and streams as the metals vaporize into the air when burned • Contribute to heavy metals that potentially may leach from solid waste landfills. • Expose the environment and water to lead and acid. • Contain strong corrosive acids. May cause burns or danger to eyes and skin. PTAC-SVX002A-EN Care and Cleaning Periodic care and cleaning of the ProSpace unit is essential to keep it running efficiently. Front Panel and Case Turn unit off and disconnect power supply. To clean, use a soft brush, water, and a mild detergent. D O N OT use bleach or abrasives. Some commercial cleaners may damage the plastic parts. Outdoor Coil I m p o rt a n t : Product failure due to improper care or lack of maintenance is not covered under warranty. Airflow restriction may cause damage to the unit. Coil on outdoor side of unit should be checked regularly. Unit will need to be removed from its sleeve to inspect dirt build-up that can occur inside of the coil. If clogged with dirt or soot, the coil should be professionally cleaned. N o t e : Never use a high-pressure sprayer on the coil. Base Pan Periodically check the base pan and clean if required. Air Filter I m p o rt a n t : Do not the operate unit without filters in place. If a filter becomes torn or damaged, it should be replaced immediately. Operating without filters in place or with damaged filters will allow dirt and dust to reach indoor coil and reduce cooling, heating, airflow, and the efficiency of the unit. Airflow restriction may cause damage to unit. This unit contains two (2) air filters. To maintain unit efficiency, clean the filters at least every 30 days (or sooner depending on application). Keeping filter clean: • Decreases the cost of operation. • Saves energy. • Prevents a clogged indoor coil. • Reduces the risk of premature component failure. To clean the air filters, vacuum off any heavy soil and contaminates. Run water through the filters and then dry thoroughly before replacing them back into the unit. PTAC-SVX002A-EN 27 Care and Cleaning Use the following checklist to ensure proper care of the ProSpace unit. Equipment operation should be checked and verified several times during each year. Clean both sides of outdoor coil. (Never use high pressure spray on coils.) Clean base pan and outdoor vent filter. Clean outdoor orifice and fan. Clean indoor coil. (Never use high pressure spray on coils.) Clean indoor fan, wire screen and front panel. Clean or install new indoor - air inlet filter(s). Clean wall sleeve and outdoor grille. Inspect cord and receptacle. Secure electrical connections. Ensure front panel is properly mounted and not damaged. Ensure wall sleeve is installed properly. Ensure heat and cool cycles operate properly. 28 PTAC-SVX002A-EN Troubleshooting Issue Possible Causes Resolution Unit does not start. • Unit may have become unplugged. • • Fuse may be blown. Ensure that the plug is securely in the wall receptacle. • Circuit breaker may be tripped. • Replace the fuse.(a) • Turn ON the unit. The unit shows green when ON and red when OFF. If the LED is not lit, there may be a problem with power or damage to the control. • Ensure that curtains, blinds, or furniture are not restricting or blocking unit airflow. • Reset to a lower or higher temperature setting. • Remove and clean filters. • Allow a sufficient amount of time for the unit to heat or cool the room. Start heating/cooling early before outdoor temperatures, cooking heat, or gatherings of people begin to make the room uncomfortable. • Close the vent door. • Check the dip switch settings for the desired comfort level. • Wait approximately three (3) minutes for the compressor to start. • The unit may be in a diagnostic condition. (Refer to the section, Intelligent Selfchecking Control.) • The unit may be set for Celsius instead of Fahrenheit. Unit makes noises. • Clicking, gurgling, and whooshing sounds are normal during the operation of the unit. Water dripping outside. • If a drain kit has not been installed, condensation run-off during very hot and humid weather is normal. (b) • If a drain kit has been installed and is connected to a drain system, check gaskets and fitting around the drain for leaks or clogs. • Wall sleeve must be installed level for proper drainage of the condensation. Check that the installation is level and make any necessary adjustments. Unit not cooling or heating the room. • Unit may be OFF or in wall thermostat mode. • Unit may be in a protection or diagnostic failure mode. (Refer to the section, Intelligent Self-checking Control.) • Unit air discharge section is blocked. • Temperature setting is not high or low enough. Setpoint limits may not allow the unit to heat or cool the room to the desired temperature. • Unit air filters are dirty. • Room is excessively hot or cold when unit is started. • Vent door left open. • Unit may be in a protection of diagnostic failure mode. (Refer to the section, Intelligent Self-checking Control.) • Compressor is in time delay mode. There is a protective time delay (approximately 3 seconds) on starting the compressor after a power outage (or restarting after it has been turned OFF) to prevent tripping of the compressor overload. Unit display shows strange numbers/ characters. Water dripping inside. PTAC-SVX002A-EN • Wall sleeve is not installed level. 29 Tr o u b l e s h o o t i n g Issue Ice or frost forms on the indoor coil. Compressor protection. (a) (b) 30 Possible Causes Resolution • Low outdoor temperature. • • Dirty air filters. When the outdoor temperature is approximately 55°F (12.7°C) or below, frost may form on the indoor coil when the unit is in cooling mode. Switch unit to FAN mode until the ice or frost melts. • Remove and clean the air filters. • Random Compressor Restart; whenever the unit is plugged in or the power has been restarted, a random compressor restart occurs. After a power outage, the compressor restarts after approximately three (3) minutes. • Compressor Protection; to prevent short cycling of the compressor, there is a random star-up delay of three (3) minutes and a minimum compressor runtime of three (3) minutes. • Power may have cycled so the compressor is in a restart protection mode. If the circuit breaker is tripped or the fuse has blown more than once, contact a qualified electrician. If the unit is installed where condensation can drip into unwanted areas, install an accessory drain kit and connect it to the draining system. PTAC-SVX002A-EN Notes PTAC-SVX002A-EN 31 Notes Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, Trane offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.Trane.com. Trane has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2015 Trane All rights reserved PTAC-SVX002A-EN 12 Nov 2015 We are committed to using environmentally Supersedes (New) conscious print practices that reduce waste. ">
/
Download
Bare en venlig påmindelse. Du kan se dokumentet lige her. Men vigtigst af alt har vores AI allerede læst det. Den kan forklare komplekse ting i enkle vendinger, besvare dine spørgsmål på ethvert sprog og hjælpe dig med hurtigt at navigere selv de længste eller mest komplicerede dokumenter.
Annonce