advertisement
▼
Scroll to page 2
of 12
Air Conditioning Mistral High wall Fan Coils Air Conditioning ENVIRONMENTAL COMFORT Sabiana s.p.a. • via Piave, 53 • 20011 Corbetta • Milano • Italy • phone +39.02.97203.1 r.a. / +39.02.97270429 / +39.02.97270576 fax +39.02.9777282 / +39.02.9772820 • www.sabiana.it • [email protected] Copertina MISTRAL.indd 1 B/01/09 COD. A4240100 MISTRAL - EX - 01/09 Mistral High wall Fan Coils ISO 9001 - Cert. n° 0545/3 Unit heaters Radiant panels Fan coils Air handling units Flues ENVIRONMENTAL COMFORT 20-01-2009 10:28:16 CONTENTS • Constructional characteristics and main components • Dimensions and weights • Eurovent certification • Operating limits • Cooling capacity • Heating capacity • Water side pressure drop • Infra-red remote control for SI-IR • SI model - Electrical connections • SI/SI-IR accessories Air Con d i t i o n i n g ENVIRONMENTAL COMFORT Page 3 3 4 4 5 5 5 6 8 10 Mistral HIGH WALL FAN COIL The Sabiana Mistral high wall fan coils harmonoiusly combine the needs of performance, silence, ease of installation and simple maintenance, through a range of three models available with both elegantly designed infra-red remote controls and wall-mounted controls. SI Model without infra-red remote control SI/SI-IR accessories 2 way valve 2 way valve ON-OFF with thermoelectric actuator. Suitable for the connection with Ø 12mm pipes. Actuator characteristics: -Max. ambient temperature: -Supply: -Power: -Protection: -Reaction time: -Max. glycol content of water: 50°C 230 V - 50/60 Hz 5W IP 44 approx. 4 min. 50% Valves characteristics: -Max. rated pressure: -Kvs: -Maximum pressure difference for valve to close (∆PMAX): -Valve connection (external thread): 16 bar 1,7 80 kPa 1/2” SI units can be operated using the Sabiana wall-mounted controls after having completed the simple electrical connections. SI-IR Model with infra-red remote control SI-IR units are operated using the elegantly designed infra-red remote control, providing complete control over the functions of the unit. Frame Change-Over CH 15-25 Frame for installation of valves (non included). To be used with the following controls: TMO-T and TMO-T-AU. Automatic summer/winter switch to be installed in contact with the water circuit. RED BLACK Sabiana take part to the Eurovent program of fan coil performance certification. The official figures are published in the Eurovent web site (www.eurovent-certification.com). The tested performances are: • Cooling total emission at the following conditions: - Water temperature +7°C E.W.T. +12°C L.W.T. - Entering air temperature +27°C dry bulb +19°C wet bulb • Cooling sensible emission at the following conditions: - Water temperature +7°C E.W.T. +12°C L.W.T. - Entering air temperature +27°C dry bulb +19°C wet bulb • Heating emission (2 pipe units) at the following conditions: - Entering water temperature +50°C (entrata) - Entering air temperature +20°C - Water flow rate as for the cooling conditions • Heating emission (4 pipe units) at the following conditions: - Water temperature +70°C E.W.T. +60°C L.W.T. - Entering air temperature +20°C • Fan absorption • Water pressure drop • Sound power TME low temperature cut-out thermostat To be used with the following controls: TMO-T and TMO-T-AU. To be fitted between the coil fins; when connecting the control, the TME probe cable must be separated from the power supply wires. It stops the fan when the water temperature is lower than 38°C and it starts the fan when is higher than 42°C. The descriptions and illustrations provided in this publication are not binding: Sabiana reserves the right, whilst maintaining the essential characteristics of the types described and illustrated, to make, at any time, without the requirement to promptly update this piece of literature, any changes that it considers useful for the purpose of improvement or for any other manufacturing or commercial requirements. 11 Copertina MISTRAL.indd 2 20-01-2009 10:28:18 Constructional characteristics and main components Versions SI three models without valves for wired wall controls SI-IR three models without valves with IR infra-red remote control SI-IR-V two models with 3 way fitted valves and with IR infra-red remote control Cabinet Made from a strong ABS structure with exceptional mechanical characteristics and excellent resistance to ageing. Filter Washable-regenerable synthetic filter, readily accessible. Fan assembly and electric motor Tangential fan with three-speed motor, ensuring high efficiency and minimal noise levels. Heat exchange coil Made from copper tubes and aluminium fins; the coil has two 12mm diameter copper pipe connections. Supplied complete with the connectors to be fitted at the end of the water pipes and on the fan coil connections. Condensate collection tray Made from plastic, with 16mm OD fitting. Drilling template Each unit is supplied with a paper template for mounting the unit on the wall. Dimensions and weights Model SI / SI-IR SI / SI-IR SI / SI-IR SI-IR-V SI-IR-V 1 2 3 2 4 Weight kg 11 11 14 11 14 L mm 830 830 907 830 907 H mm 285 285 290 285 290 P mm 189 189 195 189 195 Eurovent certification The following standard rating conditions are used: Cooling (summer mode) Air temperature: +27°C dry bulb Water temperature: +7°C E.W.T. +19°C wet bulb +12°C L.W.T. Heating (winter mode) Air temperature: +20°C Water temperature: +50°C E.W.T. water flow rate as for the cooling conditions Models without valve (accessory on request) Model Speed Air flow Cooling total emission Cooling sensible emission Heating ∆p Cooling ∆p Heating Fan Sound power Sound pressure m3/h kW kW kW kPa kPa W dB(A) dB(A) SI / SI-IR 1 2 334 376 1.60 1.73 1.28 1.39 2.07 2.22 5.0 6.0 4.0 6.0 22 24 36 39 27 30 1 3 436 1.91 1.70 3.05 7.0 7.0 26 46 35 m3/h kW kW kW kPa kPa W dB(A) dB(A) SI-IR-V 2 1 2 3 439 478 540 1.60 1.75 1.95 1.45 1.60 1.75 2.95 3.20 3.50 13.0 15.0 18.0 9.0 14.0 17.0 40 42 46 47 51 55 38 42 44 SI / SI-IR 1 2 403 522 1.95 2.31 1.54 1.86 2.50 3.00 6.0 9.0 4.0 6.0 36 38 39 42 30 33 2 3 632 2.60 2.30 4.15 11.0 7.0 42 48 37 SI / SI-IR 1 2 570 691 3.00 3.39 2.36 2.72 4.05 4.52 9.0 12.0 9.0 11.0 36 38 47 50 39 41 Models with fitted valve Model Speed Air flow Cooling total emission Cooling sensible emission Heating ∆p Cooling ∆p Heating Fan Sound power Sound pressure * SI-IR-V 4 1 2 3 507 527 600 2.20 2.35 2.50 1.75 1.90 2.10 3.85 4.15 4.50 18.0 22.0 25.0 14.0 16.0 19.0 48 50 60 53 56 60 45 47 49 Sound pressure in open field conditions at 1 metre from front of unit Operating limits Water flow MAX. working pressure: 8 bar Air flow Suitable relative humidity 25-85% Supply Single phase 230V / 1 / 50Hz MIN. height: 2,3 m MAX. height: 3,2 m Installation MIN. entering water temperature: +5°C MAX. entering water temperature: +60°C MIN. entering air temperature: +6°C MAX. entering air temperature: +40°C 3 3 780 3.60 2.80 5.30 14.0 14.0 47 55 44 Cooling emission Entering air temperature: +27°C Model Speed SI / SI-IR 1 SI / SI-IR 2 SI / SI-IR 3 SI-IR-V 2 SI-IR-V 4 Air flow m3/h 436 376 334 632 522 403 780 691 570 540 478 439 600 527 507 Max Med Min Max Med Min Max Med Min Max Med Min Max Med Min +19°C wet bulb Relative humidity 47% Water temperature Water temperature Water temperature Water temperature EWT 5 - LWT 10 EWT 7 - LWT 12 EWT 9 - LWT 14 EWT 12 - LWT 17 Water Total Sensible Water Total Sensible Water Total Sensible Water Total Sensible flow emission emission flow emission emission flow emission emission flow emission emission l/h kW kW l/h kW kW l/h kW kW l/h kW kW 406 2.36 1.74 329 1.91 1.70 244 1.42 1.36 186 1.08 1.08 368 2.14 1.57 298 1.73 1.39 222 1.29 1.22 169 0.98 0.98 339 1.97 1.44 275 1.60 1.28 205 1.19 1.12 153 0.89 0.89 556 3.23 2.37 447 2.60 2.30 335 1.95 1.86 256 1.49 1.49 490 2.85 2.08 397 2.31 1.86 298 1.73 1.63 225 1.31 1.31 413 2.40 1.73 335 1.95 1.54 253 1.47 1.35 186 1.08 1.08 772 4.49 3.32 619 3.60 2.80 476 2.77 2.63 375 2.18 2.18 714 4.15 3.04 583 3.39 2.72 444 2.58 2.40 344 2.00 2.00 630 3.66 2.64 516 3.00 2.36 394 2.29 2.08 299 1.74 1.74 420 2.45 2.00 334 1.95 1.75 284 1.65 1.65 225 1.30 1.30 387 2.25 1.90 299 1.75 1.60 267 1.55 1.55 212 1.20 1.20 361 2.10 1.80 277 1.60 1.45 245 1.45 1.45 203 1.10 1.10 533 3.10 2.30 430 2.50 2.10 319 1.85 1.85 253 1.50 1.50 498 2.90 2.20 404 2.35 1.90 298 1.75 1.75 238 1.40 1.40 464 2.70 2.05 378 2.20 1.75 283 1.65 1.65 225 1.30 1.30 Heating emission Entering air temperature: +20°C Model Speed SI / SI-IR 1 SI / SI-IR 2 SI / SI-IR 3 SI-IR-V 2 SI-IR-V 4 Max Med Min Max Med Min Max Med Min Max Med Min Max Med Min Air flow m3/h 436 376 334 632 522 403 780 691 570 540 478 439 600 527 507 Water temperature Water temperature Water temperature EWT 60 - LWT 50 EWT 50 - LWT 40 EWT 45 - LWT 40 Water flow Total emission Water flow Total emission Water flow Total emission l/h kW l/h kW l/h kW 292 3.60 202 2.70 383 2.33 267 3.06 181 2.08 343 1.98 244 2.80 166 1.92 314 1.82 451 4.90 276 3.70 522 3.18 354 4.07 241 2.79 452 2.64 293 3.37 200 2.31 377 2.18 630 6.90 404 4.67 744 4.60 534 6.14 371 4.28 680 3.93 462 5.32 322 3.72 588 3.40 300 3.50 210 2.45 404 2.35 275 3.20 189 2.20 361 2.10 253 2.95 176 2.05 344 2.00 386 4.40 275 3.20 533 3.10 357 4.15 245 2.85 490 2.85 331 3.85 227 2.65 446 2.60 Water side pressure drop Pressure drop for mean water temperature of 10°C; for different temperatures multiply the pressure drop figure by the K correction factors in the table: °C 20 30 40 50 60 70 80 K 0,94 0,90 0,86 0,82 0,78 0,74 0,70 SI-IR Infra-red remote control Infra-red remote control The Mistral SI-IR are very high quality units designed for residential application. The elegance of the aesthetics, the electronic management and the top quality components ensure perfect integration into the environment and a high level of comfort. A.MODE Used to select the mode of operation (cooling, heating, dehumidifying/dry, fan). B.ROOM TEMPERATURE SET Used to set the room temperature or program the timer. C.FAN ( ) Used to set the fan speed in sequence to automatic, high, medium, low. D.SWING Used to start or stop vertical swing of the louvers or flaps and to set the required airflow direction upwards or downwards. E.TIMER Used to set or cancel timer operation. F. SLEEP ( ) Used to set or cancel the SLEEP function. G.SMART ( ) Upon pressing this button the appliance automatically establishes the most suitable mode of operation to ensure maximum comfort. H.SUPER ( ) Used to start or stop fast cooling (fast cooling works with the fan at high speed and the temperature automatically set at 18°C). I. ON/OFF Used to switch the appliance on and off. Note:the settings continue to appear on the display even with the fan coil switched off. Indicator symbols on the liquid crystal display: SI-IR Infra-red remote control Connection terminal block SI-IR 1 / SI-IR 2 / SI-IR-V 2 SI-IR 3 / SI-IR-V 4 SI Model - Electrical connections Wiring diagram Electrical connections with Sabiana electronic controls - Manual speed switch. Identification Code - Manual Summer/Winter switch. - Electronic thermostat for fan control (ON-OFF). TMO - T 9060161 - Electronic thermostat for valve(s) control (ON-OFF) (the fan keeps working). - It allows to control the low temperature cut-out thermostat (TME). - It allows to install the Summer/Winter switch centralized and remote, or to control it with an automatic change-over fitted on the water pipe (for 2 pipe installations only). The latter case needs the adjustment of the jumper on the control board (see the instruction leaflet supplied with the control). Same characteristics as TMO-T, adding: Identification Code - Manual or automatic speed switch. - Electronic thermostat for fan control (ON-OFF). TMO - T - AU 9060164 - Electronic thermostat for valve(s) control (ON-OFF). - Simultaneus thermostatic control of the valves and fan (ON-OFF). - It allows to install the Summer/Winter switch centralized and remote, or to control it with an automatic change-over fitted on the water pipe (for 2 pipe installations only). The latter case needs the adjustment of the jumper on the control board (see the instruction leaflet supplied with the control). Note:with 4 pipe installations and continuous chilled and hot water supply, it allows the automatic summer/winter change-over in accordance to the room temperature (-1°C = Winter, +1°C = Summer, Dead Zone 2°C). LEGEND SI = SI electrical board TMO-T = TMO-T electrical board TMO-T-AU = TMO-T-AU electrical board CH = Remote Summer/Winter switch E = Valve set (2 pipe installation) SI Model - Electrical connections Electrical connections of more units with Sabiana electronic controls A maximum of 4 units can be connected together; the units must be of the same size. Identification Code TMO - T 9060161 Identification Code TMO - T - AU 9060164 WARNING: a maximum of 4 units can be connected together; the units must be of the same size. Accessori SI/SI-IR 3 way valve frame Water flow control kit with 3 way ON-OFF valves with thermoelectric actuator. The kit includes the connection pipes and the valves. This kit allows the water fl ow to be diverted from the coil in order to cut out operation. Descrizption Q.ty A.3 way valve kit with support 1 B. Paper installation template 1 C. Spacer 1 D. Adhesive insulation for fan coil base 1 E. Condensate drain pipe 1 F. Insulation for condensate drain pipe 1 G. Expansion plugs with screws4 H. Plastic strap 1 I. Screws M5 x 6,5 2 L. Supporting bracket (mod. 1 and 2) 1 M. Screws 3,5 x 6,5 1 N. Screw M5 x 10 (mod. 3 and 4) 1 O. Supporting bracket (mod. 3 and 4) 1 P. Supporting bracket (mod. 3 and 4) 1 Instructions 1 3 way valve technical data MAX. operating temperature Actuator movement Power supply Power supply cable Input Regulation signal Ambient operating temperature Thrust Max. differential pressure: - Maximum aperture flow coefficient - By-pass flow coefficient Reaction time (in operation) Protection Heating element Weight 10 100°C 2,5 mm 230 V 0,6 mt 5W ON-OFF 0 ÷ 50°C 180 N (40 lbs) 1,7 Kvs 1,5 Kvs 2 - 4 min. IP 42 PTC 0,13 kg CONTENTS • Constructional characteristics and main components • Dimensions and weights • Eurovent certification • Operating limits • Cooling capacity • Heating capacity • Water side pressure drop • Infra-red remote control for SI-IR • SI model - Electrical connections • SI/SI-IR accessories Air Con d i t i o n i n g ENVIRONMENTAL COMFORT Page 3 3 4 4 5 5 5 6 8 10 Mistral HIGH WALL FAN COIL The Sabiana Mistral high wall fan coils harmonoiusly combine the needs of performance, silence, ease of installation and simple maintenance, through a range of three models available with both elegantly designed infra-red remote controls and wall-mounted controls. SI Model without infra-red remote control SI/SI-IR accessories 2 way valve 2 way valve ON-OFF with thermoelectric actuator. Suitable for the connection with Ø 12mm pipes. Actuator characteristics: -Max. ambient temperature: -Supply: -Power: -Protection: -Reaction time: -Max. glycol content of water: 50°C 230 V - 50/60 Hz 5W IP 44 approx. 4 min. 50% Valves characteristics: -Max. rated pressure: -Kvs: -Maximum pressure difference for valve to close (∆PMAX): -Valve connection (external thread): 16 bar 1,7 80 kPa 1/2” SI units can be operated using the Sabiana wall-mounted controls after having completed the simple electrical connections. SI-IR Model with infra-red remote control SI-IR units are operated using the elegantly designed infra-red remote control, providing complete control over the functions of the unit. Frame Change-Over CH 15-25 Frame for installation of valves (non included). To be used with the following controls: TMO-T and TMO-T-AU. Automatic summer/winter switch to be installed in contact with the water circuit. RED BLACK Sabiana take part to the Eurovent program of fan coil performance certification. The official figures are published in the Eurovent web site (www.eurovent-certification.com). The tested performances are: • Cooling total emission at the following conditions: - Water temperature +7°C E.W.T. +12°C L.W.T. - Entering air temperature +27°C dry bulb +19°C wet bulb • Cooling sensible emission at the following conditions: - Water temperature +7°C E.W.T. +12°C L.W.T. - Entering air temperature +27°C dry bulb +19°C wet bulb • Heating emission (2 pipe units) at the following conditions: - Entering water temperature +50°C (entrata) - Entering air temperature +20°C - Water flow rate as for the cooling conditions • Heating emission (4 pipe units) at the following conditions: - Water temperature +70°C E.W.T. +60°C L.W.T. - Entering air temperature +20°C • Fan absorption • Water pressure drop • Sound power TME low temperature cut-out thermostat To be used with the following controls: TMO-T and TMO-T-AU. To be fitted between the coil fins; when connecting the control, the TME probe cable must be separated from the power supply wires. It stops the fan when the water temperature is lower than 38°C and it starts the fan when is higher than 42°C. The descriptions and illustrations provided in this publication are not binding: Sabiana reserves the right, whilst maintaining the essential characteristics of the types described and illustrated, to make, at any time, without the requirement to promptly update this piece of literature, any changes that it considers useful for the purpose of improvement or for any other manufacturing or commercial requirements. 11 Copertina MISTRAL.indd 2 20-01-2009 10:28:18 Air Conditioning Mistral High wall Fan Coils Air Conditioning ENVIRONMENTAL COMFORT Sabiana s.p.a. • via Piave, 53 • 20011 Corbetta • Milano • Italy • phone +39.02.97203.1 r.a. / +39.02.97270429 / +39.02.97270576 fax +39.02.9777282 / +39.02.9772820 • www.sabiana.it • [email protected] Copertina MISTRAL.indd 1 B/01/09 COD. A4240100 MISTRAL - EX - 01/09 Mistral High wall Fan Coils ISO 9001 - Cert. n° 0545/3 Unit heaters Radiant panels Fan coils Air handling units Flues ENVIRONMENTAL COMFORT 20-01-2009 10:28:16
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement