EIP CD30 Owner's Manual
Add to my manuals16 Pages
EIP CD30 is capable of removing moisture from the air, preventing problems like rust, rot, mold, and condensation. It works by drawing in air through an inlet grille, cooling it below its dew point, and collecting the condensed moisture. The cooled air is then reheated and discharged into the room at a lower relative humidity. It is suitable for use in offices, shops, houses, restaurants, public houses, and more. The device features a control humidistat that allows you to set the desired relative humidity level.
advertisement
OWNER’S MANUAL
Drawing : - TPC137
Issue : - 7
Date : - 23/11/16
www.eipl.co.uk
Page 1 of 16
Drawing : - TPC137
Issue : - 7
Date : - 23/11/16
UNPACKING
Carefully remove the CD30 dehumidifier unit from its transit box and visually check for signs of transit damage. If there is evidence of damage DO NOT attempt to operate the unit, call your supplier for advice. Do not discard the packing; it will be useful when transporting the dehumidifier unit in the future.
INTRODUCTION
Dehumidifiers remove moisture from the air that is circulating through the unit.
The resulting reduction of relative humidity helps prevent rust, rot, mould, mildew and condensation within the room, or other enclosed spaces where the dehumidifier is used.
A dehumidifier consists of a motor-compressor unit, a refrigerant condenser, an air circulating fan, a refrigerated surface, a means of collecting and disposing the condensed moisture and a cabinet to house these components.
The fan draws air through the refrigerated surface and cools it below its dew point, removing moisture which is collected and led away. The cool air then passes the hot condenser, where it is reheated. With the addition of other radiated heat the air is discharged into the room at a higher temperature but lower relative humidity than when the air entered the unit. Continuous circulation of the room air through the dehumidifier unit gradually reduces the relative humidity in the room.
The CD30 has been designed for the exacting conditions which can prevail in offices, shops, houses, restaurants, public houses etc. It combines lightness and compactness with high reliability and strength. The gas, which is used inside the hermetically sealed refrigeration circuit is R134a and contains no
CFC’s and has therefore a zero ozone depletion factor.
Page 2 of 16
Drawing : - TPC137
Issue : - 7
Date : - 23/11/16
SPECIFICATIONS
M
ODEL
:
CD30 CD30E
H
EIGHT
:
W
IDTH
:
L
ENGTH
:
W
EIGHT
:
A
IRFLOW
:
300mm
304mm
550mm
23 Kg
150 M
3
/Hr
300mm
350mm
550mm
25 Kg
150 M
3
/Hr
P
OWER
S
UPPLY
:
P
OWER
F
INISH
:
E
FFECTIVE
V
OLUME
:
240V, 1 ph, 50Hz
360W (max)
240V, 1 ph, 50Hz grey epoxy coating
85M
3
460W (max) grey epoxy coating
85M
3
R
EFRIGERANT
T
YPE
/Q
TY
:
R134a (170g) R134a (170g)
"This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The refrigeration system is hermetically sealed.
The Global Warming Potential (GWP) of refrigerants used in products manufactured by Ebac
Industrial Products Ltd is as follows
R134a – 1300
R407c – 1610
For type and weight of refrigerant contained in this unit, please refer to the product data label"
Page 3 of 16
Drawing : - TPC137
Issue : - 7
Date : - 23/11/16
INSTALLATION
POSITIONING:
Position the dehumidifier unit in the center of the room to be conditioned if at all possible. However if a damp patch is particularly apparent the outlet grille should be pointed towards it.
NOTE: Both inlet grille and outlet grille of the dehumidifier unit must have clear space around them and not be obstructed in anyway.
WIRING:
Connect the power mains cable to a 5 or 13 Amp power supply. As follows:-
230V supply
Brown
Blue
Green/Yellow
Live
Neutral
Earth (ground)
DRAINAGE:
Connect a 12.5mm inside diameter hose to the condensate outlet pipe
(positioned centrally, beneath the air inlet grille). Secure the hose using a worm drive clip. The hose should at no point be raised higher than the outlet pipe. Hose should be ran to a permanent drain. Failure to observe this requirement will result in flooding of the dehumidifier.
Page 4 of 16
Drawing : - TPC137
Issue : - 7
Date : - 23/11/16
OPERATION
The operation of the dehumidifier is to remove moisture from the air by having it condense on the cold tubes of the evaporator coil. The air then passes over the hot condenser coil and returns to the conditioned space slightly warmer and dryer than when it entered the dehumidifier unit.
AIR MOVING SYSTEM:
Air is drawn in through the inlet grille at the rear of the dehumidifier (below the handle) and over the two heat exchanges (evaporator/condenser coils) under the influence of the axial fan, which is driven by the motor. The operation of the fan is to run continuously whenever the power is supplied to the dehumidifier. The fan motor used in the dehumidifier unit is induction protected i.e. the motor is able to take stalled current without burning out the motor windings.
DEFROST OPERATION:
Should the ambient temperature fall below 15°C the ice will form on the evaporator coil as the air is passed over it, and in turn the efficiency of the unit will drop. To prevent the build up of ice on the evaporator coil a timer is incorporated to energize the hot-gas defrost valve every 55mins for a period of 4mins. Operating the hot-gas valve causes the evaporator coil to defrost and the water to drain down to the condensate pan and into the drainage tube.
HIGH TEMPERATURE CUTTOUT:
The CD30 dehumidifier has been designed to work in ambient temperatures between -5°C and +35°C. Should the temperature in the room become excessive a thermostat within the compressor casing will open and dehumidifying will stop, until the thermostat resets itself.
HUMIDISTAT CONTROL:
The CD30 is fitted with a control humidistat, which measures the relative humidity of the air within the room to be conditioned. The humidistat incorporates a pointer and scale, which can be adjusted, and set to a relative humidity level that is acceptable to maintain the required conditions within the room. The humidistat controls the on/off function of the dehumidifier, when the relative humidity of the air in the room falls below the set point of the humidistat the dehumidifier will switch off, but when the relative humidity of the air starts to rise again and passes the set point the unit will switch on. The humidistat is used for the on/off function as it is a cost effective method which ensures power is only used when needed.
Page 5 of 16
Drawing : - TPC137
Issue : - 7
Date : - 23/11/16
WARNING:
• Due to the high pressures within the refrigeration circuit, under no circumstances must direct heat be applied to the evaporator coil in an attempt to remove the build up of ice.
• No attempt should be made to cut open any part of the refrigeration circuit due to high pressures and gas involved.
• If the unit is switched off at the mains power supply for any reason, the unit must be allowed to stand at rest for at least three minutes before restarting. Failure to do so may cause the unit to blow the fuses owing to the compressor due to there being a refrigerant imbalance.
Page 6 of 16
SPECIAL FEATURES
(Where Fitted)
Temperature Controlled Defrost
Drawing : - TPC137
Issue : - 7
Date : - 23/11/16
The ‘CD30E’ Dehumidifier unit can be fitted with temperature sensitive devices which will operate in conjunction with the defrost control. In normal operation the defrost control will come into operation every 55minutes, this is to ensure that there will be no build up of ice at lower temperatures, but where year round conditions need to be maintained the dehumidifier will have to operate across a wider range of temperatures. To ensure that the dehumidifier operates most efficiently this temperature sensitive device will restrict the operation to the times when the evaporator coil is at –2ºC.
Heated Condensate Drainage Tube
The ‘CD30E’ dehumidifier unit can be fitted with a heater tape, which will run
the length of the condensate drainage tube. The effect of this heated condensate drainage tube will ensure that when the drainage point for the unit is not in the same room, but is run outside the room and could fall below freezing point, the tube will be warm enough to still allow the condensate to flow. Ensure that the heater tape does not protrude past the condensate drainage tube, if it does then the tape should be doubled up and fed back up into the condensate tube.
Control Humidistat
This humidistat operates in the same way as the normal humidistat to control the on/off function of the dehumidifier units, but is factory pre-set at 55% RH to maintain the relative humidity air at the set point.
Alarm Humidistat
This humidistat, which has been factory pre-set at 70% RH, allows for connection to an external warning system. This warning indicating system will be monitored by the customer and will warn and indicate when the relative humidity of the air within the room has risen above a warning level due to a fault, either with the dehumidifier or due to some other circumstances and will require a service engineer.
NOTE RATING OF ALARM HUMIDISTAT IS 3.5A @ 240V
Alarm Wiring: Plug L – Normally open contacts
Plug N – Close on humidity rise
Plug E – Earth
Page 7 of 16
Drawing : - TPC137
Issue : - 7
Date : - 23/11/16
ROUTINE SERVICE
WARNING:
ENSURE THAT THE POWER CORD TO THE MACHINE HAS
BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE
SERVICE. THE SERVICING AND REPAIR OF THIS UNIT
SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED
PERSON.
To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows:
Removal of the cover is achieved by means of four screws at the sides of the unit at base level. With the cover removed all maintenance can be carried out.
1. Clean the surface of the evaporator and condenser coils by blowing the dirt out from behind the fins with compressed air. Hold the nozzle of the air hose away from the coil (approx 6”) to avoid damaging the fins. Alternatively, vacuum clean the coils.
WARNING:
DO NOT STEAM CLEAN REFRIGERATION COILS
2. Check that the fan is firmly secured to the motor shaft and that the fan rotates freely.
The motor is sealed for life and does not require any lubrication
3. To check the refrigerant charge, run the unit for 15 minutes and briefly remove the cover. The evaporator coil should be evenly frost coated across its surface. At temperatures above 25°C, the coil may be covered with droplets of water rather than frost. Partial frosting accompanied by frosting of the thin capillary tubes, indicates loss of refrigerant gas or low charge.
4. Check all wiring connections.
I
F ANY OF THE PRECEDING PROBLEMS OCCUR
,
CONTACT THE
E
BAC
S
ERVICE
C
ENTER PRIOR TO CONTINUED OPERATION OF THE UNIT TO
PREVENT PERMANENT DAMAGE
.
Page 8 of 16
Drawing : - TPC137
Issue : - 7
Date : - 23/11/16
REPAIRS
1. Should an electrical component fail, consult the Factory Service
Center to obtain the proper replacement part.
2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory
Service Center prior to initiating this action.
Any competent refrigeration technician will be able to service the equipment. The following procedure must be used: a. The source of the leak must be determined and corrected. b. The machine should be thoroughly evacuated before recharging. c. The unit must be recharged with refrigerant measured accurately by weight. d. For evacuation and recharging of the machine, use the crimped and brazed charging stub attached to the side of the refrigerant compressor.
The charging stub should be crimped and rebrazed after servicing. N
EVER
allow permanent service valves to be fitted to
any part of the circuit. Service valves may leak causing further loss of refrigerant gas.
3. The refrigerant compressor fitted to the dehumidifier is a durable unit that should give many years of service. Compressor failure can result from the machine losing its refrigerant gas. The compressor can be replaced by a competent refrigeration technician.
Failure of the compressor can be confirmed by the following procedure: a. Establish that power is present at the compressor terminals using a voltmeter. b. With the power disconnected, check the continuity of the internal winding by using meter across the compressor terminals. An open circuit indicates that the compressor should be replaced. c. Check that the compressor is not grounded by establishing that a circuit does not exist between the compressor terminals and the shell of the compressor.
Page 9 of 16
Drawing : - TPC137
Issue : - 7
Date : - 23/11/16
S
YMPTOM
Little or no airflow
Little or no water extraction
Little or no defrost when required
TROUBLESHOOTING
C
AUSE
1. Loose fan on shaft
2. Fan motor burnt out
3. Dirty refrigeration coils
4. Loose electrical wiring
5. Control humidistat either set too high or malfunctioning
1. Insufficient air flow
2. Compressor fault
3. Loss of refrigerant gas
1. Faulty Timer
2. Faulty bypass timer
R
EMEDY
1. Tighten fan
2. Replace the fan motor
3. See Routine Maintenance
Section
4. Check the wiring diagram to find fault and repair
5. Adjust humidistat as required or replace
1. Check all of the above
2. Contact the Factory
Service Center
3. Contact the Factory
Service Center
1. Contact the Factory
Service Center
2. Contact the Factory
Service Center
Page 10 of 16
Drawing : - TPC137
Issue : - 7
Date : - 23/11/16
CD30
SPARE PARTS LIST
D
ESCRIPTION
Product Part Number
Compressor
Compressor OH Protector
Compressor Relay
By-Pass Valve
Condenser Coil
Evaporator Coil
Filter Dryer
Fan Motor
Fan Blade
Control Humidistat
Warning Humidistat
Frostat
Control Defrost Device
PCB Timer
Solenoid Coil
1139500
3022132
3021519
3021520
3020811
3020740
2013713
3020937
3035752
3031516
3031516
1613700
3030422
1139525
3022132
3021519
3021520
3020811
3020740
2013713
3020937
3035752
-
-
1016900
3030422
P
-
-
ART
1013700
3022132
3021519
3021520
3020811
3020740
2013713
3020937
3035752
1601900
3030422
N
UMBER
-
1135400
3022132
3021519
3021520
3020811
3020740
2013713
3020937
3035752
3031516
1613700
3030422
1138100
3022132
3021519
3021520
3020811
3020740
2013713
3020937
3035752
-
-
1601900
3030422
1138600
3022132
3021519
3021520
3020811
3020740
2013713
3020937
3035752
3040129 3040129 3040129 3040129 3040129 3040129
3035141 3035141 1132200 1132200 1132200 1132200
3035141 3035141 - - - -
-
-
1601900
3030422
Humidistat Knob
Control Knob
3090611 3090611
- -
Control Knob Cap (black) 3090612 3090612
Warning Knob Cap (orange) 3090645 3090645
Panel Mounting Plug 3035997 3035997
Free Socket
Feet
Mains Cable
Condensate Drain Tube
Worm Drive Clip
Cover fixing Clip Nut
3035998
3100758
-
-
-
-
-
-
-
2019708 2019708 2019708 2019708
-
-
-
-
-
-
-
-
-
-
-
- - - -
3100758 3100758 3100758 3100758
3031225 3031225 2133711 2133711 2131145 2131144
3014338 3014338 3014338 3014338 3014338 3014338
3086101 3086101 3086101 3086101 3086101 3086101
3080507 3080507 3080501 3080501 3080501 3080501
Spare parts available online www.EIPLDIRECT.com
Page 11 of 16
Drawing : - TPC137
Issue : - 7
Date : - 23/11/16
CD30I STAND & CD30I INDICATOR BOX
SPARE PARTS LIST
D
ESCRIPTION
CD30I Stand
Adjustable Tilt Guide
CD30I Indicator Box
Red Neon Lamp
M16 Gland Type
Resistor 180K Ohms
Female Insert Contact Type
Hood
Cable Seal
Female Contact
Green Neon Indicator Lamp
Sealing Washer
6-way Terminal Block
P
ART
N
UMBER
1139535
3050305
1139530
3032272
3032512
3032883
3033810
3033811
3033813
3033815
3034584
3035423
3036810
Page 12 of 16
Drawing : - TPC137
Issue : - 7
Date : - 23/11/16
WARNINGS
This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the application in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
If the SUPPLY CORD is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person in order to avoid hazard.
This product contains fluorinated greenhouse gases covered by the Kyoto
Protocol. The refrigeration system is hermetically sealed.
The Global Warming Potential (GWP) of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows
R134a – 1300
R407c – 1610
For type and weight of refrigerant contained in this unit, please refer to the product data label
Due to the high pressures within the refrigeration circuit, under no circumstances must direct heat be applied to the evaporator coil in an attempt to remove the build-up of ice.
No attempt should be made to cut open any part of the refrigeration circuit due to high pressures and gas involved.
If the unit is switched off at the mains power supply for any reason, the unit must be allowed to stand at rest for at least three minutes before restarting.
Page 13 of 16
Drawing : - TPC137
Issue : - 7
Date : - 23/11/16
Page 14 of 16
Drawing : - TPC137
Issue : - 7
Date : - 23/11/16
Page 15 of 16
Drawing : - TPC137
Issue : - 7
Date : - 23/11/16
UK Head Office
Ebac Industrial Products Ltd
St Helens Trading Estate
Bishop Auckland
County Durham
DL14 9AD
Tel: +44 (0) 1388 664400
Fax: +44 (0) 1388 662590 www.eipl.co.uk
American Sales Office
Ebac Industrial Products Inc
700 Thimble Shoals Blvd.
Suite 109, Newport News
Virginia, 23606-2575
USA
Tel: +01 757 873 6800
Fax: +01 757 873 3632 www.ebacusa.com
German Sales Office
Ebac Industrial Products Ltd.
Gartenfelder Str. 29-37
Gebäude 35
D-13599, Berlin
Germany
Tel: +49 3043 557241
Fax: +49 3043 557240 www.eip-ltd.de
Page 16 of 16