advertisement
TECHNICAL MANUAL
FREEZER : F23-S, F23-SH
F49-S, F49-SH
F72-S, F72-SH
REFRIGERATOR : R23-S, R23-SH, R23-G
R49-S, R49-SH, R49-G
R72-S, R72-SH, R72-G
MERCHANDISERS : GR26H, GR48S, GR72H
- 1 -
A. GENERA L
1. SPECIFICATION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A3
1) GENERAL
2) MAIN COMPONENTS
2. REFRIGERATION CYCLE - - - - - - - - - - - - - - - - - - - - - - - - - - A9
3. TROUBLE SHOOTING - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A11
1) CHECKING THE POWER SUPPLY
2) CHECKING THE POWER SUPPLY OF CONTROL BOARD
3) CHECKING THE CONTROL PART OF REFRIGERATION CYCLE
4) CHECKING THE DEFROST PART
5) WHEN THE UNIT DOES NOT COOL
6) WHEN THERE IS A ABNORMAL NOISE
7) WHEN THE TEMPERATURE DOES NOT DISPLAY
8) WHEN THE LAMP DOES NOT LIGHT
9) CHECKING SENSOR
4. FEATURE CHART - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A22
5. WIRING DIAGRAM - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A28
6. REPLACEMENT OF COMPONENTS - - - - - - - - - - - - - - - - - - A37
- 2 -
1. SPECIFICATION
1.1 GENERAL - SOLID DOOR FREEZER & REFRIGERATOR (FULL DOOR / HALF DOOR)
PRODUCT
MODEL
Capacity
Net Capacity
Exterior Dimension (W)
(Including casters
Door Handles)
(D)
(H)
Interior Dimension
Product Weight
Door Type
(W)
(D)
(H)
SOLID (FULL/HALF) DOOR
FREEZER
F23-S /
F23-SH
650 ℓ(23ft
3 )/
648 ℓ(22.9ft
3 )
552 ℓ(19.5ft
3 )/
551 ℓ(19.4ft
3 )
695
㎜
(27.4”)
F49-S /
F49-SH
1,385 ℓ(49ft
3 )/
1,381 ℓ(48.8ft
3 )
1,195 ℓ(42.2 ft
3 )/
1,191 ℓ(42.1 ft
3 )
1,400
㎜
(55.2”)
SOLID (FULL/HALF) DOOR
F72-S /
F72-SH
2,035 ℓ(72ft
3 )/
2,028 ℓ(71.6ft
3 )
1,790 ℓ(63.2ft
3 )/
1,782 ℓ(63ft
3 )
R23-S /
R23-SH
650 ℓ(23ft
3 )/
648 ℓ(22.9ft
3 )
552 ℓ(19.5ft
3 )/
551 ℓ(19.4ft
3 )
1,980
㎜
(78.0”)
838
㎜ (33”)
695
㎜
(27.4”)
REFRIGERATOR
R49-S /
R49-SH
1,385 ℓ(49ft
3 )/
1,381 ℓ(48.8ft
3 )
2,035 ℓ(72ft
3 )/
2,028 ℓ(71.6ft
3 )
1,195 ℓ(42.2 ft
3 )/
1,191 ℓ(42.1 ft
3 )
1,790 ℓ(63.2ft
3 )/
1,782 ℓ(63ft
3 )
1,400
㎜
(55.2”)
R72-S /
R72-SH
1,980
㎜
(78.0”)
600
㎜
(23.6
”)
124
㎏(273 lb)/
126
㎏(278 lb)
Swing 1EA/
Swing 2EA
1,305
(51.4
㎜
”)
194
㎏(428 lb)/
198
㎏(437 lb)
Swing 2EA/
Swing 4EA
2,127
㎜ (83.7”)
1,885
㎜
(74.2
”)
635
㎜ (25”)
600
㎜
(23.6
”)
1,545
㎜ (60.8”)
255
㎏(562 lb)/
260
㎏(573 lb)
121
㎏(267 lb)/
123
㎏(271 lb)
Swing 3EA/
Swing 6EA
Swing 1EA/
Swing 2EA
1,305
(51.4
㎜
”)
1,885
(74.2
㎜
”)
186
㎏(410 lb)/
190
㎏(419 lb)
253
㎏(558 lb)/
258
㎏(569 lb)
Swing 2EA/
Swing 4EA
Swing 3EA/
Swing 6EA
Door Material Stainless steel (STS)
Shelves 4EA 8EA 12EA 4EA 8EA 12EA
Power Voltage AC 115V/60Hz
Plug in - Installation
Amps
Compressor
Refrigerant
Range of Temperature
Door auto-close equipment
Door stop
NEMA 5-15P
8.5A
3/5HP
10.5A
4/5HP
NEMA 5-20P
12.0A
1HP
7.5A
1/3HP
NEMA 5-15P
7.5A
1/3HP
10.0A
3/5HP
250 g
(8.8 oz)
R-404A
340 g
(12.0 oz)
Below -18℃ (0°F)
400 g
(14.1 oz)
210 g
(7.4 oz)
R-134a
220 g
(7.8 oz)
R-404A
300 g
(10.6 oz)
0℃ ~ 4℃ (+32°F ~ +40°F)
Auto-close for Spring
120˚ Stop
Air suction equipment
Caster 4” × 4EA
Air damper
4” × 6EA 4” × 4EA
Condensing unit Sliding Type
◈ Above specifications are subjected to change without prior notice for quality improvement.
◈ The nameplate(includes Serial Number) is located on the upper left of the cabinet interior.
- 3 -
4” × 6EA
Type of Condenser
Condenser pipe
Diameter
Condenser Fan Motor
Dryer
Temperature Control
Running Indication
Interior Temp.
Indication
Interior Lamp
(Incandescent lamp)
Defrost for evaporator
Defrost sheath heater
Defrost pan heater
Drain heater
Door switch
Power switch
1.2 MAIN COMPONENTS - SOLID DOOR FREEZER & REFRIGERATOR
PRODUCT
MODEL
SOLID (FULL/HALF) DOOR
FREEZER
F23-S /
F23-SH
F49-S /
F49-SH
F72-S /
F72-SH
NEK2150GK
(Embraco)
NT2178GKV
(Embraco)
NT2192GKV
(Embraco)
Compressor
(Manufacture)
Compressor
Capacity(kcal/h)
Type of Compressor motor
LBP 628 LBP 903 LBP 1051
SOLID (FULL/HALF) DOOR
REFRIGERATOR
R23-S /
R23-SH
R49-S /
R49-SH
R72-S /
R72-SH
NW108LHB1
(DAEWOO-Korea)
NEK2150GK
(Embraco)
LBP 325 LBP 628
Compressor O.L.P
Compressor Relay
Starting Capacitor
Running Capacitor
T0873/G9
MST18RN-
3041
RVA9AD3C-121
189~227 ㎌
/ 165V
25 ㎌ / 400V
CSR
CRA1773-
3029
GA3RMU0002
RVA2AE3C-105
243~292 ㎌
/ 165V
35 ㎌ / 400V
4TM801SFBZZ-52
R6R8MD22SS
125 ㎌ / 200V
16 ㎌ / 250V
T0873/G9
RVA9AD3C-121
189~227 ㎌
/ 165V
25 ㎌ / 400V
Type of Evaporator
Evaporator pipe
Diameter
Cooling Fan Motor
9.52mm (3/8")
Cu pipe + Al fin + Blue color coating
12.7mm
(1/2 ”)
IS3225LTSA, 120V/60Hz
9.52mm (3/8")
Cu pipe + Al fin
7.00mm (0.28")
MA7425W1, 120V/60Hz
OD 25.4mm (1"), XH-9, 30g(1.06oz)
Thermistor
Digital Display
Digital Display
40W × 1EA 40W × 2EA 40W × 1EA
Heated defrost (Control of thermistor)
450W 670W 944W
60W 128W 90W
9W
SP201R-7DR, AC125V
SL112A, AC125V/12A
Off cycle
-
-
-
40W × 2EA
- 4 -
2.1 GENERAL - GLASS DOOR REFRIGERATOR
PRODUCT GLASS (FULL) DOOR REFRIGERATOR
MODEL
Capacity
Net Capacity
Exterior Dimension
(Including casters
Door Handles)
Interior Dimension
Product Weight
Door Type
Door Material
Shelves
Power Voltage
Plug in - Installation
Amps
Compressor
Refrigerant
(W)
(D)
(H)
(W)
(D)
(H)
Range of Temperature
Door auto-close equipment
Door stop
Air suction equipment
Caster
R23-G
650 ℓ
(23 ft 3 )
552 ℓ
(19.5 ft 3 )
695
㎜
(27.4”)
600
(23.6
126
㎜
”)
㎏
(278 lb)
Swing 1EA
4EA
R49-G
1,385 ℓ
(49 ft 3 )
1,195 ℓ
(42.2 ft 3 )
1,400
㎜
(55.2”)
835
㎜ (32.9”)
2,127
㎜ (83.7”)
1,305
㎜
(51.4
”)
635
㎜ (25”)
1,545
㎜ (60.8”)
200
㎏
(441 lb)
Swing 2EA
Glass + Al(A6063S)
8EA
AC 115V/60Hz
NEMA 5-15P
7.5A
1/3HP
7.5A
1/3HP
R-134a
230 g
(8.1 oz)
R-134a
230 g
(8.1 oz)
0℃ ~ 4℃ (+32°F ~ +40°F)
Auto-close for Spring
120˚ Stop
Air damper
4” × 4EA
R72-G
2,035 ℓ
(72 ft 3 )
1,790 ℓ
(63.2 ft 3 )
1,980
㎜
(78.0”)
1,885
(74.2
㎜
”)
271
㎏
(597 lb)
Swing 3EA
12EA
8.5A
3/5HP
R-404A
330 g
(11.6 oz)
4” × 6EA
Condensing unit Sliding Type
◈ Above specifications are subjected to change without prior notice for quality improvement.
◈ The nameplate(includes Serial Number) is located on the upper left of the cabinet interior.
- 5 -
2.2 MAIN COMPONENTS - GLASS DOOR REFRIGERATOR
PRODUCT GLASS (FULL) DOOR REFRIGERATOR
MODEL
Compressor
(Manufacture)
Compressor Capacity(kcal/h)
Type of Compressor motor
Compressor O.L.P
Compressor Relay
Starting Capacitor
Running Capacitor
Type of Evaporator
Evaporator pipe Diameter
Cooling Fan Motor
Type of Condenser
Condenser pipe Diameter
Condenser Fan Motor
Dryer
Temperature Control
Running Indication
Interior Temp. Indication
Interior Lamp (LED)
Defrost for evaporator
Defrost sheath heater
Defrost pan heater
Drain heater
Door switch
Power switch
Light switch
R23-G
NW108LHB1
(DAEWOO-Korea)
LBP 325
R49-G
CSR
4TM801SFBZZ-52
R6R8MD22SS
R72-G
NEK2150GK
(Embraco)
LBP 628
T0873/G9
RVA9AD3C-121
125 ㎌ / 200V
16 ㎌ / 250V
189~227 ㎌ / 165V
25 ㎌ / 400V
Cu pipe + Al fin + Blue color coating
9.52mm (3/8")
IS3225LTSA, 120V/60Hz
Cu pipe + Al fin
7.00mm (0.28")
MA7425W1, 120V/60Hz
OD 25.4mm (1"), XH-9, 30g(1.06oz)
Thermistor
Digital Display
Digital Display
6W x 1EA 6W x 2EA
Off cycle
-
-
-
SP201R-7DR, AC125V
SL112A, AC125V/12A
RL1-3, 16A/250V, ON-OFF
6W x 3EA
- 6 -
3.1 GENERAL - MERCHANDISERS
PRODUCT MERCHANDISERS
MODEL
Capacity
Net Capacity
Exterior Dimension
(Including casters
Door Handles)
Interior Dimension
Net Weight
Door Type
Door Material
Shelves
Power Voltage
Plug in - Installation
Amps
Compressor
(W)
(D)
(H)
(W)
(D)
(H)
Refrigerant
Range of Temperature
Door auto-close equipment
Door stop equipment
Air suction equipment
Caster
Condensing unit
Door switch
Power(or Lamp) switch
GR26H
736 ℓ (26 ft
3 )
677 ℓ (23.9 ft
3 )
720
㎜ (28.4”)
844
㎜ (33.3”)
2,017
㎜ (79.4”)
640
㎜ (25”)
719
㎜ (28.3”)
1,584
㎜ (62.4”)
130
㎏ (287 lb)
Swing 1EA
Glass + PVC
4EA
3.9A
1/4 HP
GR48S
1359 ℓ (48 ft
3 )
1339 ℓ (47.3 ft
3 )
1,350
㎜ (53.2”)
780
㎜ (30.7”)
2,012
㎜ (79.2”)
1,280
㎜ (50.4”)
642
㎜ (25.3”)
1,562
㎜ (61.5”)
215
㎏ (474 lb)
Sliding 2EA
Glass + PVC
8EA
AC 115V/60Hz
NEMA 5-15P
10.0A
1/2 HP
R-134a
300g (10.6 oz) 460g (16.2 oz)
Auto-close for Spring
120˚ Stop
0℃ ~ 4℃ (32℉ ~ 40℉)
Auto-close for slope
-
-
Adjust foot 4EA
-
Adjust foot 6EA
-
Sliding Type
-
SL112A, AC125V/12A
GR70H
1982 ℓ (70 ft
3 )
1877 ℓ (66.3 ft
3 )
1,980
㎜ (78”)
835
㎜ (32.9”)
2,126
㎜ (83.7”)
1,885
㎜ (74.2”)
635
㎜ (25”)
1,545
㎜ (60.8”)
325
㎏ (716 lb)
Swing 3EA
Glass + Al
12EA
10.0A
3/5 HP
R-404A
360g (12.7 oz)
Auto-close for Spring
120˚ Stop
Air damper
Adjust foot 6EA
-
◈ Above specifications are subjected to change without prior notice for quality improvement.
◈ The nameplate(includes Serial Number) is located on the upper left of the cabinet interior.
- 7 -
3.2 MAIN COMPONENTS - MERCHANDISERS
PRODUCT MERCHANDISERS
MODEL
Compressor
(Manufacture)
Compressor Capacity(kcal/h)
Type of Compressor motor
Compressor O.L.P
Compressor Relay
Starting Capacitor
Running Capacitor
Type of Evaporator
Evaporator pipe Diameter
Cooling Fan Motor
Type of Condenser
Condenser pipe Diameter
Condenser Fan Motor
Dryer
Temperature Control
Running Indication
Interior Temp. Indication
Interior Lamp
(Fluorescent lamp)
Ad. Panel Fluorescent Lamp
Ballast
Ballast Name
(Manufacture)
SMPS
SMPS Name
(Manufacture)
Defrost for evaporator
Defrost sheath heater
Defrost pan heater
Drain heater
GR26H
SK182C-L2U
(SAMSUNG)
LBP 256
RSCR
4TM444NHBYY
J531Q32E4R7M1802
-
12 ㎌/250V
GR48S
CAJ4476Y(A)
(Tecumseh-France)
HBP 1946
CSIR
CRA38014
3ARR3*2M*
250 ㎌/160V
-
GR70H
NEK2150GK
(Embraco)
LBP 628
CSR
T0873/G9
RVA9AD3C-121
189~227 ㎌
/ 165V
25 ㎌ / 400V
Cu pipe + Al fin
9.52 mm (3/8")
IS3225LTSA, 120V/60Hz
Cu pipe + Al fin
9.52 mm (3/8")
MA7425W1, 120V/60Hz
Thermostat
(GNF-250L)
OD 25.4mm (1"), XH-9, 30g(1.06oz)
Thermostat
(GNF-240L)
-
-
7.00mm (0.28")
Thermostat
(GNF-246L)
32W × 1EA
20W × 1EA
32W(Double)×1EA
B232I120RH-A
(ADVANCE)
-
-
-
-
-
32W × 1EA
32W × 1EA
32W(Double)×1EA
B232I120RH-A
(ADVANCE)
-
-
Off cycle
-
-
-
6W(LED) × 3EA
20W(LED) × 1EA
-
-
60W(DC12V)
LVP-60-12
(MEAN WELL)
-
-
-
- 8 -
2. REFRIGERATION CYCLE
Mechanical refrigeration is accomplished by continuously circulating, evaporating, and condensing a fixed supply of refrigerant in a closed system. Evaporation occurs at allow temperature and pressure while condensation occurs at high temperature and pressure. Thus it is possible to transfer heat fom an area of low temperature (i.e., refrigerated compartment) to an area of high temperature (i.e., surrounding of refrigerator).
CONDENSER
CAPILLARY TUBE
COMPRESSOR
EVAPORATOR
THE BASE REFRIGERATION CYCLE
Beginning the cycle at the evaporator inlet the low pressure liquid expands, absorbs heat (so refrigerator inner-cabinet is cooled), and evaporates, changing to allow low pressure gas at the evaporator outlet.
The compressor pumps this gas from the evaporator, increases its pressure, and discharges the high pressured- temperature gas to the condenser.
The condenser lets high pressured- temperature gas emit the heat (so surrounding of the condenser is warmed) in order to make it condense.
The capillary tube prevents high pressured- temperature liquid from entering the evaporator in order to lower the pressure in the evaporator and control the flow of refrigerant into the evaporator automatically.
Eventually the desired air temperature in refrigerator inner-cabinet is reached, the thermostat (temperature controller) will break the electrical circuit to the compressor motor and stop the compressor.
- 9 -
As the temperature of the air rises, the thermostat (or controller) remakes the electrical circuit. The compressor starts, and cycle continues.
The schematic refrigeration (or freezing) cycle of F23/F49/F72/R23/R49/R72/GR26/GR48/GR70 is like below.
MODEL COMPRESSOR
F23-S/SH, R72-G,GR70H NEK2150GK
F49-S/SH
F72-S/SH
R23/R49-S/SH,R23/R49-G
R72-S/SH
GR26H
GR48S
NT2178GKV
NT2192GKV
NW108LHB1
CAJ4461Y(A)
SK182C-L2U
CAJ4476Y(A)
No.
1
2
Part Name
COMPRESSOR
CONDENSER
7
8
9
5
6
3
4
EVAPORATOR
DRYER
ACCUMULATOR
DISCHARGE PIPE
DRYER CONNECT PIPE
CAPILLARY TUBE
SUCTION PIPE (INNER-CABINET)
10 SUCTION PIPE (COMPRESSOR)
11 CHARGE PIPE (COMPRESSOR)
12 CHARGE PIPE (DRYER)
Description
C1220TS-O,H
C1220TS-O,H
C1220T-H
C1220T-1/4H
C1220T-O
C1220T-O
C1220T-H
C1220T-O
C1220T-O
C1220T-O
C1220T-O
Remark
- 10 -
3. TROUBLESHOOTING
1) CHECKING THE POWER SUPPLY
① F23 / F49 / F72 / R23 / R49 / R72 ② GR26H / GR48S / GR70H
Is the power cord
Plugged in?
YES
NO
Plug in
Is the power cord
Plugged in?
YES
NO
Plug in
Is the rated voltage supplied?
YES
NO
Correct
Is the rated voltage supplied?
YES
NO
Correct
Is the power cord normal?
YES
NO
Defective power cord
Is the power switch
“OFF” position?
YES
NO
NORMAL
Move to “ON” position
- 11 -
Is the power cord normal?
YES
NO
Defective power cord
NORMAL
2) CHEKING THE POWER SUPPLY OF CONTROL BOARD
① F23 / F49 / F72 / R23 / R49 / R72
Is the rated voltage supplied to the C/B?
YES
NO
Check wiring
Does the fuse fail?
YES
Defective fuse
NO
NOTES
* C/B: Control Board
(Printed Circuit Board)
* Fuse Spec: AC250V, 8A
* Transformer Spec.
Primary: AC115V
Secondary: AC12V (Red wire)
AC20V (Blue wire)
Is the coil winding of transformer open?
YES
NO Defective transformer
Is the secondary output volt, of trans, normal
NO
Defective transformer
YES
Is the DC 24V supplied to coil part in relay?
NO
Check C/B
YES
- 12 -
Does the contact part in relay continue?
YES
NORMAL
NO
Defective
Relay
3) CHECKING THE CONTROL PART OF REFRIGERATION CYCLE
① F23 / F49 / F72 / R23 / R49 / R72
Check the power supply
Is the to comp. connected properly?
NO
Correct
Are the sensors in
C/B connected properly?
NO
Correct
YES
YES
Check the resistance of T-Sensor
NO
Defective
T-sensor
& OLP in comp. assembled properly?
Correct
YES
YES
Is the temp. displayed in D/B properly?
NO
Defective
MICOM
Check the continuity of OLP in compressor
NO
Defective
OLP
YES
YES
Check the temperature set point
Check the continuity of relay in compressor
YES
NO
Defective relay
YES
Defective compressor
NO
Temperature resetting
Check the power supply of control board
NOTES
* C/B: Control Board
* D/B: Display Board
* OLP: Over load Protector
- 13 -
② GR26H / GR48S / GR70H
Check the power supply
When the thermostat is OFF.
Does the comp. run?
NO
YES
Defective thermostat
Is the to comp. connected properly?
NO
YES
Correct
& OLP in comp. assembled properly?
YES
Check the continuity of OLP in compressor
NO
Defective OLP
YES
Correct
Check the continuity of relay in compressor
NO
Defective relay
YES
Defective compressor
- 14 -
4) CHECKING THE DEFROST PART
① F23 / F49 / F72
Check the power supply
Do the B/M and D-
Sensor located in place?
NO
Correct
YES
Do the wiring to the heater and B/M connected properly?
NO
Check wiring
YES
Check the resistance of
D-sensor
YES
NO
Defective
D-Sensor
Does the B/M continue below
41℉(5℃)
YES
NO
Defective
Bi-Metal
Dose the defrost output on C/B normal in defrost mode?
NO Defective
Control Board
YES
Defective MICOM
Are the defrost heaters normal?
NO
Defective heater
YES
NOTES
* C/B: Control Board
* B/M: Bi-Metal
(Temp. Limiting Controller)
- 15 -
② R23 / R49 / R72
Check the power supply
Do the D-Sensor located in place?
NO
Correct
YES
Check the resistance of
D-sensor
YES
NO
Defective
D-Sensor
Dose the defrost output on C/B normal in defrost mode?
NO
Defective
Control Board
YES
Defective micom
NOTES
* C/B: Control Board
- 16 -
5) WHEN THE UNIT DOES NOT COOL
① All Models
Does the compressor run normally?
NO
Check the control part of refrigeration cycle
YES
Is the unit located in a level place?
YES
NO
Correct
Is the temperature set point proper?
NO
Temperature resetting
YES
Are the goods loaded properly?
NO
Correct
YES
Does the cool air leak?
YES
Check door gasket
NO
Does the frost form excessively in evaporator?
YES
Freezer: Check the defrost part
NO
Refrigerator: forced defrost dust on condenser fin?
NO
Clean
Does the cond.
NO
(eva.) fan motor rotate normally?
Defective motor, fan
YES
Does the refrigerant leak?
YES
Correct
NO
Is the refrigerant line restricted?
YES
Correct
NO
Excluding GR26H, GR48S
GR70H
Is the contact of door switch normal?
NO
Defective door switch
YES
When door closed.
Are the door S/We pushed by the top of door?
NO
Apply spacer between door switch and the top of door
YES
Check compressor
- 17 -
6) WHEN THERE IS A ABNORMAL NOISE
① All Models
Is the unit located in a level place?
YES
NO
Correct
Is the high voltage supplied?
YES
Adjust voltage
NO
Are the pipes rattled?
YES Reform to be free of contact
NO
Are the parts assembled tightly?
NO
Tighten
YES
- 18 -
Are the fans bent?
YES
Defective fan
NO
Do the fans rotate well?
NO
Defective fan, motor
YES
Is there any noise in motor?
YES
Defective motor
NO
Comp. is running but the unit does not cool
YES
7) WHEN THE TEMPERATURE DOES NOT DISPLAY
① F23 / F49 / F72 / R23 / R49 / R72
Check the power supply
Check the power supply in control board
Is the connect ion between C/B and D/B properly?
NO
Tighten
YES
Is the micom inserted on C/B properly?
YES
Replace display board
NOTES
* C/B: Control Board
* D/B: Display Board
NO
Tighten
- 19 -
8) WHEN THE LAMP DOES NOT LIGHT
① F23 / F49 / F72 / R23 / R49 / R72 ② GR26H / GR48S / GR70H
Check the power supply
Check the power supply
Check the connecting points with socket
YES
Adjust the lamp for good connection
Is the lamp defective?
YES
NO
Defective lamp
Check the continuity of lamp switch
YES
NO
Defective lamp switch
When door closed.
Are the door S/We pushed by the top of door?
NO
Apply spacer between door switch and the top of door
YES
Check wiring
Check the connecting points with socket
NO
Adjust the lamp for good connection
YES
Is the lamp defective?
YES
NO
Defective lamp
Check the continuity of lamp switch
YES
NO
Defective lamp switch
Check the continuity of ballast
YES
Check wiring
NO
Defective ballast
* Incandescence Lamp: 40W * Fluorescent Lamp: 32W
- 20 -
9) CHECKING SENSOR
Sensor assembly consists of T-sensor (lead wire: orange) and D-sensor (lead wire: blue).
The T-sensor is used for cabinet temperature control and the D-sensor is used for defrost control.
The resistance of the sensor varies depending on temperature.
If you Immerse the sensor in a glass containing ice water for 2 minutes and then check for the resistance between sensor leads, the normal reading is 7.88 ㏀ (T-sensor) / 30 ㏀ (D-sensor).
Temperature (℉/℃)
-5 / -21
0 / -18
10 / -12
23 / -5
32 / 0
41 / 5
50 / 10
60 / 16
70 / 21
T-sensor (±6.5%)
Resistance (㏀)
D-sensor (±5.5%)
23.04
19.76
14.65
10.10
7.88
6.20
7.91
3.82
3.00
79.17
68.92
52.61
37.55
30.00
24.13
19.53
15.56
12.48
- 21 -
4. FEATURE CHART
1) F23/R23-S
2) F49/R49-S
- 22 -
3) F72/R72-S
4) F23/R23-SH
- 23 -
5) F49/R49-SH
6) F72/R72-SH
- 24 -
7) R23-G
8) R49-G
- 25 -
9) R72-G
10) GR26H
AD. Panel
Door (Glass)
Door handle
BALLAST
AD. PANEL
FAN COVER
COOLING FAN
COOLING FAN MOTOR
EVAPORATOR
LAMP
COVER LAMP
DOOR FRAME
WATER COLLECTOR
DRAIN HOSE
LAMP
SHELF SUPPORT
SHELF
DOOR HANDLE
Lower grille
Adjust foot
[ Front view ]
LOWER GRILLE
CONDENSER
CONDENSER FAN MOTOR MOTOR BRKT COMPRESSOR
[ Side view ]
DRYER
SUCTION PIPE
- 26 -
11) GR48S
AD. Panel
Door (Glass)
Door handle
Lower grille
Adjust foot
[ Front view ]
COOLING FAN COVER
BALLAST
AD. PANEL
LAMP
COOLING FAN
LAMP
LAMP TUBE
COOLING FAN MOTOR
EVAPORATOR
WATER COLLECTOR
DRAIN HOSE
SHELF SUPPORT
SHELF
DOOR HANDLE
DOOR FRAME
CENTER POST
LOWER GRILL
CONDENSER
CONDENSER FAN MOTOR
MOTOR BRKT
COMPRESSOR
[ Side view ]
DRIER
SUCTION PIPE
12) GR70H
- 27 -
5. WIRING DIAGRAMS
1) F23-S
2) F49-S
- 28 -
3) F72-S
4) R23-S
- 29 -
5) R49-S
6) R72-S
- 30 -
7) R23-SH
8) R49-SH
- 31 -
9) R72-SH
10) F23-SH
- 32 -
11) F49-SH
12) F72-SH
- 33 -
13) R23-G
6) R49-G
- 34 -
6) R72-G
7) GR26H
- 35 -
8) GR48S
9) GR70H
- 36 -
6. REPLACEMENT OF COMPONENTS
1) CONDENSING UNIT
(F49/F72/R49/R72/GR70H) (F23/R23/GR26H) a) Unplug the power cord before service. b) Remove screw securing the lower grille.
* Remove screw securing the reinforce angle.(GR48S)
(GR48S)
(F49/F72/R49/R72/GR70H) (F23/R23/GR26H) a) Separate the compressor harness out of the terminal block. b) Remove screws securing the unit base plate and pull out condensing unit with care. c) Replace the necessary com-ponent.
(GR48S)
※ CAUTION
1. Please pull out or push in the unit base plate carefully to prevent capillary tube, pipes and wires from damaging.
2. It is recommend to arrange wires after you push in the unit base plate.
- 37 -
2-1) LAMP (GR26H) a) Unplug the power cord before service. b) Remove screw securing the Ad. Panel Frame and pull out the Ad. Panel Frame with care. c) Separate the Ad. Panel. d) Separate the Lamp from the Lamp Holder. e) Separate the Lamp Socket and replace the Lamp with care.
♠ Lamp Description: AC115V, F17T8/TL950
- 38 - a) Unplug the power cord before
service. b) Separate the Lamp from the
Lamp Holder. c) Separate the Lamp Socket and
the Lamp wire. d) Replace the Lamp with care.
2-2) LAMP (GR48S) a) Unplug the power cord before service. b) Remove screw securing the Ad. Panel Side. c) Separate the Ad. Panel. d) Separate the Lamp from the Lamp Holder. e) Separate the Lamp Socket and replace the Lamp with care.
♠ Lamp Description: AC115V, FHF32SSEX-D-5
- 39 - a) Unplug the power cord before service. b) Separate the Lamp from the
Lamp Holder. c) Separate the Lamp Socket and
the Lamp wire. d) Replace the Lamp with care
.
B. OPERATION AND ELECTRONIC CONTROLLER
FUNCTION
1. OPERATION FOR F23, F49, F72, R23, R49, R72 MODELS - - - - - B2
1) BASIC OPERATION
2) ELECTRONIC CONTROLLER SETTING MODE
3) NORMAL CONTROL PROCESS
4) ERROR CODE
2. OPERATION FOR GR26H, GR48S, GR70H MODELS - - - - - - - - - B12
1) BASIC OPERATION
2) DEFROST
3) CONTROL TEMPERATURE
4) LAMP
3. INSTRUCTION FOR RE-HINGING DOOR - - - - - - - - - - - - - - - - - B13
- 40 -
1. OPERATION FOR F23/F49/F72(FREEZER), R23/R49/R72(REFRIGERATOR)
1) BASIC OPERATION
① Plug in the power cord and turn on the power switch located on the bottom of the top grille right side.
[ The unit should be plugged into a 115V±10%, 60Hz (F23, F49, F72, R23, R49, R72 models) ]
② Display panel will be lit for 2 seconds with buzzer then displays cabinet interior temperature (T-sensor) and running conditions.
* Freezer : If cabinet interior temperature is higher than 14℉ (-10℃) compressor will run without
delay, and lower than 14℉ (-10℃), compressor will run after 3 minutes.
* Refrigerator : If cabinet interior temperature is higher than 50℉ (10℃) compressor will run
without delay, and lower than 50℉ (10℃), compressor will run after 3 minutes.
③ The default OPERATING TEMPERATURE SETTING
* Freezer :Temperature set point (setting mode sign [St]) is –5℉ (-20℃)
Temperature differential set point (setting mode sign [di]) is 8℉ (4℃)
Range of adjustable set point: -22℉~ 8℉(-30℃ ~ -10℃)
* Refrigerator : Temperature set point (setting mode sign [St]) is 36℉ (4℃) in solid door refrigerator
Temperature set point (setting mode sign [St]) is 35℉ (4℃) in glass door refrigerator
Temperature differential set point (setting mode sign [di]) is 8℉ (4℃)
Range of adjustable set point: 25℉~ 50℉ (2℃ ~10℃)
④ Defrost frequency
* Freezer : It is controlled by MICOM and the default defrost frequency is 12 hours.
* Refrigerator : It is controlled by MICOM and the default defrost frequency is 12 hours.
⑤ The light inside the cabinet comes on when the door is opened in Solid Door models
while light is always on in Glass Door models.
The cabinet interior cooling fan has 3 seconds delay when the door is closed.
When COMP. is OFF, EVA. fan repeats ON and OFF according to setting times
If door is opened , EVA. fan OFF and then closed the door, EVA. fan repeats ON and OFF according to setting times
- 41 -
⑥ If door is opened, door open warning sign (LED) will turn on.
If door is opened more than 30 seconds, the sound alarm beeps 3 times, if open more than 60 seconds, the sound alarm beeps 5 times and if open more than 5 minutes, the sound alarm will beep continuously.
⑦ Cabinet interior temperature
* Freezer : If it is higher than 14℉ (-5℃), the panel displays [Hi] and
lower than -50℉ (-40℃), the panel displays [Lo].
* Refrigerator : If it is higher than 68℉ (15℃), the panel displays [Hi] and
lower than 14℉ (-2℃), the panel displays [Lo].
- 42 -
2) ELECTRONIC CONTROLLER SETTING MODE
Display
St di th
Description
Temperature Setting Mode
Temperature Differential Setting Mode
Cabinet Temperature Verification Mode dt tb
Defrost Frequency Setting Mode
Rapid Freeze Mode (Freezer Only) dF Forced Defrost Mode
SE Temperature Unit Converter mode(℉ ↔℃)
※ In converting Temperature Unit (℉ ↔℃), 1℉ (1℃) deviation can occur.
- 43 -
No Setting Mode
1
Temperature
Setting
Mode
Mode
Sign
How to Setting
“St”
1.To enter this mode, press [MODE/SET] and [UP or DOWN] simultaneously until [St] is displayed.
2. Then press [MODE/SET] to see current temperature set point.
3. To change the set point, press [UP or DOWN] until the desired value is displayed.
4. At the end of the sequence, press [MODE/SET] to set the value.
5. To display the cabinet temperature again, press [UP or DOWN] until [th] is displayed and then press [VERIFY].
2
Temperature
Differential
Setting
Mode
“di”
6. Range of adjustable set point : -22℉~8℉(-30℃~ -10℃) (Freezer)
Range of adjustable set point : 25℉~50℉(2℃ ~ 10℃) (Refrigerator)
1. To enter this mode, press [MODE/SET] and [UP or DOWN] simultaneously until [di] is displayed.
2. Then press [MODE/SET] to see current temperature differential.
3. To change the set point, press [UP or DOWN] until the desired value is displayed.
4. At the end of the sequence, press [MODE/SET] to set the value.
5. To display the cabinet temperature again, press [UP or DOWN] until [th] is displayed and then press [VERIFY].
6. Range of adjustable set point : 4℉~16℉(2℃~10℃) (Freezer)
Range of adjustable set point : 4℉~16℉(2℃~10℃) (Refrigerator)
(The Unit of Setting : 2℉(2℃))
- 44 -
No
3
Setting Mode
Defrost
Frequency
Setting
Mode
Mode
Sign
How to Setting
“dt”
1. To enter this mode, press [MODE/SET] and [UP or DOWN] simultaneously until [dt] is displayed.
2. Then press [MODE/SET] to see current defrost frequency.
3. To change the defrost frequency, press [UP or DOWN] until the desired value is displayed.
4. At the end of the sequence, press [MODE/SET] to set the value.
5. To display the cabinet temperature again, press [UP or DOWN] until [th] is displayed and then press [VERIFY].
4
Forced Defrost
Mode
“dF”
6. Range of adjustable defrost frequency : 4Hr to 12Hr
(The Unit of frequency : 2Hr)
1. To enter this mode, press [MODE/SET] and [UP or DOWN] simultaneously until [dF] is displayed.
2. Then press [MANUAL DF] more than 2 seconds to start forced defrost.
5
6
Cancelation of
Forced Defrost
Mode
3. During defrosting, [dF] is displayed instead of the cabinet temperature.
Flash
"dF"
1. During forced defrost, press [MANUAL DF] more than
2 seconds to stop forced defrost.
2. The [dF] will be flash 5 times and then return to normal display mode.
1. To enter this mode, press [MODE/SET] and [UP or DOWN] simultaneously until [tb] is displayed.
2. Then press [MODE/SET] more than 2 seconds to start rapid freeze mode.
Rapid Freeze
Mode
(Freezer)
"tb"
3. During rapid freeze, [tb] is displayed instead of the cabinet temperature.
- 45 -
3) NORMAL CONTROL PROCESS
No FUNCTION
1
2
Initial
Operating
Normal
Operating
FUNCTION SPEC
1. After Power ON, Display panel will be lightened for 2 seconds with buzzer then displays cabinet interior temperature.
2. If cabinet interior temperature is higher than 14℉(-10℃) Freezer or 50℉(10℃)
Refrigerator, compressor will run without delay, and lower than 14℉(-10℃)
Freezer or 50℉(10℃) Refrigerator, compressor will run after 3 minutes.
1. Compressor and condenser fan motor is controlled by T-sensor and MICOM program.
2. Compressor ON/OFF Temperature
Compressor ON : Temperature Setting Value +
(Temperature Differential Setting Value/2)
Compressor OFF : Temperature Setting Value -
(Temperature Differential Setting Value/2) ex) St: -9℉(-23℃), di: 10℉(6℃) ⇒ Compressor ON : -9+(10/2) = -4℉(-20℃),
Compressor OFF: -9-(10/2) = -14℉(-26℃)
St: 39℉(4℃), di: 10℉(6℃) ⇒ Compressor ON : 39+(10/2) = 44℉(7℃),
Compressor OFF: 39-(10/2) = 34℉(1℃)
- 46 -
No
3
FUNCTION
Rapid
Freeze
(Freezer)
FUNCTION SPEC
1. Compressor and cabinet interior cooling fan is running continuously for
120 minutes without control by sensor.
2. It is impossible to set the other modes during Rapid Freeze Mode.
It is necessary to cancel the Rapid Freeze Mode before setting the other modes.
3. If Defrost Mode become in the Rapid Freeze Mode duration,
Defrost Mode will start after the Rapid Freeze Mode finished.
4. Rapid Freeze Mode will be start after Defrost Mode finished not during
Defrost Mode. [tb] is displayed from starting the Rapid Freeze Mode.
4
Defrost
(Freezer)
1. Defrost process is like below
Process Controlled Part
Pre-Cool
Compress or On
Evaporator Fan On
Condenser Fan On
Defrost Heater Off
Defrost
Pause
Compress or Off
Evaporator Fan Off
Condenser Fan Off
Defrost Heater On
Compress or Off
Evaporator Fan Off
Condenser Fan Off
Defrost Heater Off
Evaporator
Fan Delay
Compress or On
Evaporator Fan Off
Condenser Fan On
Defrost Heater Off
Description
① It prevent exceed temperature rise during defrosting,
② Cycle is run continuously until current compressor cut-out temperature reach.
③ Maximum time: 30minutes
① Preprogrammed frequency interval
② If D-sensor is higher than 50℉, defrost heater off
③ Maximum time: 40minutes
① Time: 5minutes
① If D-sensor is lower than -4℉, fan delay terminated
② Maximum time: 10minutes
Defrost
(Refrigerator)
1. Defrost cycle can be set up by button on control panel from 4h to 12hr.
(measurement unit: 2hr / default: 12hr)
2. Defrost control change
1) Defrost start : according to the defrost cycle by set up.
2) Defrost end : Comp OFF (during MAX time), Eva fan ON, dF ON (on display screen)
3) Defrost ends regardless of time when the temp is higher than pre-set defrost end temp.
4) 'dF' is displayed on screen for 3min after defrost end.
- Defrost end time (MAX) : 30min
- Defrost end temp : 41℉(5℃)
- 47 -
No
5
FUNCTION
Default
Setting
(Freezer)
FUNCTION SPEC
1. Temperature Setting : -5℉(-20℃), Temp.Differential Setting : 8℉(4℃) in display
2. Displayed Temperature : -8℉(-21℃)(comp. off) ~ 0℉(-17℃)(comp. on)
owing to correction factor
3. T-Sensor Operating Temperature :
-9℉(-22℃)(comp. off) ~ -1℉(-18℃)(comp. on)
4. Defrost Frequency Setting : 12Hr
Default
Setting
(Refrigerator)
1. Temperature Setting : 36℉(4℃), Temperature Differential Setting : 8℉(4℃)
2. Operating Temperature : 40℉(6℃)(comp. on) ~ 32℉(2℃)(comp. off)
3. Defrost Frequency Setting : 12Hr
6
7
Back UP
Error
Display
2. The setting is memorized.
1. If cabinet interior temp. is higher than 14℉(-5℃) Freezer or 68℉ (15℃)
Refrigerator, the panel displays [Hi], and lower than -50℉(-40℃) Freezer or
14℉(-2℃) Refrigerator, the panel displays [Lo].
2. Press [down] button 5 times with pressing and holding [up] button, the Error display mode is activated and it displays errors.
3. When there are more than 2 errors, the errors are displayed alternately.
4. If you press [MODE/SET] button, the error display mode will be finished
- 48 -
4) ERROR CODE
4-1) Freezer
Error
Code
Condition Possible Cause When error occurring, operation
C1
During normal mode (not defrost mode), D-sensor sensing is • Ambient Temperature higher than 23℉ and too low (below-5℉)
Compressor does not run for • T-sensor defective
60min after compressor off
1) Register “C1”
2) Compressor ON:20Minutes
3) Compressor OFF:5Minutes
4) Operate 2),3) three times
5) Operate Normal Mode
C2
Entering defrost mode, D-sensor sensing is higher than 50℉ and
T-sensor sensing is lower than
• D-sensor defective
14℉
1) Register “C2”
2) Operate Pre-Cool step:
30Minutes
3) Defrost Heater ON: 20Minutes
4) Operate the rest Defrost Mode
C3
After defrost mode elapsed for
40minutes, D-sensor sensing is
• D-sensor defective
• Defrost heater lower than 23℉ defective
1) Register “C3”
2) Operate the rest Defrost Mode
C4
T-sensor sensing is more
• Refrigerant leak
• Control board than 18℉higher than temperature set point for 4hours
Additional Possible Cause: Too many hot goods loaded!!
defective
• Door not sealing
• Not enough defrosts
• Condenser dirty
• Sensor defective
1) Register “C4”
2) Compressor ON:20Minutes
3) Compressor OFF:5Minutes
4) Operate 2),3) three times
5) Operate Normal Mode
• N/A N/A C- No error code
- 49 -
4-2) Refrigerator
Error
Code
Condition Possible Cause When error occurring
C1
C2
C3
C4
During normal mods, Tsensor sensing lasts “Lo" status more than 60 minutes
• T-Sensor defective
• Lead defective
1) Register "C1"
2) Compressor ON : 15 Minutes
3) Compressor OFF: 5 Minutes
4) Operate 2), 3) repeatedly until the error is clear
5) Operate Normal Mode
6) Defrost cycle is operated by Dsensor
1) Register “C2”
2) Compressor OFF: 22 Minutes
During normal mode Tsensor sensing lasts "Hi"
• Sensor housing defective (due status more than 60 to other substance)
• Sensor internal defective minutes
3) Compressor ON : 15 Minutes
4) Operate 2), 3) repeatedly until the error is clear
5) Operate Normal Mode
6) Defrost cycle is operated by Dsensor
After defrost mode elapsed for 30 minutes.
D-sensor sensing is
• Not enough defrosts lower than 32°F
1) Register "C3
2) Error check
”
3) Main power reset
T-Sensor sensing is more than 18°F higher than point for 4 hours and more temperature set
• Too many hot goods loaded
• Refrigerant leak
• Control board defective
• Door not sealing
• Not enough defrosts
• Condenser dirty
• Sensor defective
1) Register “C4”
2) Compressor OFF: 15 Minutes
3) Compressor ON : 5 Minutes
4) Operate 2), 3) repeatedly until the error is clear
5) Operate Normal Mode
6) Defrost cycle is operated by Dsensor
C5
D-Sensor Sensing is over 140°F or under -
• D-Sensor defective
• Lead defective
55.4°F for 1 minute
1) Register "C5”
2) Defrost end is operated by time
(30 Minutes)
- 50 -
2. OPERATION FOR GR26H, GR48S, GR70H MODELS
1) BASIC OPERATION
① Plug in the power cord and turn on the lamp switch located on the left of the temperature controller.
[ The unit should be plugged into a 115V±10%, 60Hz]
② The controller(Thermostat) has been preset "3" position at the factory
2) DEFROST
① This unit uses an off cycle defrost. No needs any programming.
3) CONTROL TEMPERATURE
① The temperature controller is mounted on top of the cabinet interior.
② The controller has been preset "4" position at the factory to maintain the average cabinet temperature of 38℉ (3℃)
ON
OFF
LAMP S/W Only
4) LAMP
① The light comes on when the lamp switch is on.
- 51 -
5 5
TEMP. CONTROLLER
3. INSTRUCTION FOR RE-HINGING DOOR (F23/R23)
Re hinging
- 52 -
▣ To change the door mounting from right hand to left hand hinges you will need the following;
▣ Medium to large size Phillips Screwdriver
146413 Door Hinge Kit - Lower Left
146442 Door Hinge Kit - Top Left
STEP1. Remove the door (Figure 1) a) Remove the Top Grille (seven screws) b) Remove the Lower Grille (four screws) c) Remove the Top Hinge (#1) (four screws) d) Lift and remove the Door e) Remove the Bottom Hinge (#7) (four screws)
STEP2. Convert the Door a) Replace the Spring Guide (#4) with Bushing (#9)-(SEE 146413 HINGE KIT) b) Replace the Bushing (#5) with the Spring Guide (#4).
STEP3. Reinstall the Door (figure 2) a) Install Bottom Left Hinge (#1) with Bushing (#10)-(SEE 146413 HINGE KIT) b) Set Door in place on Bottom Hinge c) Insert Spring (#8) (silver) into Spring Guide (#4) as shown in figure 3-(SEE 146442 HINGE KIT) d) Install the Top Hinge (#7) as shown in figure 4-(SEE 146442 HINGE KIT)
(confirm that spring ends are engaged in the spring guide and hinge) e) Replace the Top and Lower Grilles
Note:
The silver colored spring (#8) is for left hand hinged door and the yellow color spring (#3) is for right hand hinged doors.
The letter "L" is marked on the left hand bushings (#9 and #10)
- 53 -
C. SERVICE LIST AND EXPLODED VIEW
1. COMMERCIAL FREEZERS AND REFRIGERATORS - - - - - - - - - - C2
1) F23/F49/F72-S, R23/R49/R72-S SERVICE LIST & EXPLODED VIEW
2) F23/F49/F72-SH, R23/R49/R72-SH SERVICE LIST & EXPLODED VIEW
3) R23/R49/R72-G SERVICE LIST & EXPLODED VIEW
2. MERCHANDISERS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C23
1) GR26H, GR48S, GR70H SERVICE LIST & EXPLODED VIEW
- 54 -
15
16
17
18
19
12
13
14
20
21
1. COMMERCIAL FREEZERS AND REFRIGERATORS
1-1. SERVICE LIST (F23/F49/F72-S , R23/R49/R72-S)
PART No.
No. PART NAME
Door Hinge Kit - Top Right
F23-S F49-S F72-S R23-S R49-S R72-S
146441 146441 146441 146441 146441 146441 1
2 Door Hinge Kit - Top Left NA 146442 146442 NA 146442 146442
3
4
5
6
Door Hinge Kit - Lower Right
Door Hinge Kit - Lower Left
Door Hinge Kit - Lower Center
Control PCB Assembly (115V)
Used thru 12/2014
Control PCB Assembly (115V)
Universal (℉/℃) PCB
Main Transformer (115V)
146412 146412 146412 146412 146412 146412
NA 146413 146413 NA 146413 146413
NA NA 146414 NA NA 146414
146416 146417 146418 150313 150313 150313
150539 150540 150541 150538 150538 150538
146420 146420 146420 146420 146420 146420 7
8
9
10
11
11-1
DC Relay
Relay Wire Harness
Front PCB Wire Harness
Temperature Sensor use up to 12/2011
Sensor Kit (Includes
T-sensor and D-sensor)
Pilaster
146421 146421 146421 146421 146421 146421
146423 146423 146423 146423 146423 146423
146424 146424 146424 146424 146424 146424
146425 146427 146429
146426 146428 146430 146426 146428 146430
146411 146411 146411 146411 146411 146411
22
23
Shelf Clip 146489 146489 146489 146489 146489 146489
Door Assembly - Right Hand 146436 146437 146439 146436 146437 146439
Door Assembly - Left Hand
Door Gasket
Lamp (115V)
Lamp Socket
Lamp Cover
Top Grille Assembly (115V)
Top Grill Cover - Right
Front PCB Assembly
Used thru 12/2014
Front PCB Assembly
Universal (℉/℃) PCB
Control Decal
NA 146438 146440 NA 146438 146440
146444 146444 146445 146444 146444 146445
146408 146408 146408 146408 146408 146408
146409 146409 146409 146409 146409 146409
146410 146410 146410 146410 146410 146410
146433 146434 146435 146433 146434 146435
146431 146431 146431 146431 146431 146431
146419 146419 146419 146419 146419 146419
150537 150537 150537 150537 150537 150537
146432 146432 146432 146432 146432 146432
- 55 -
No.
33
34
35
30
31
32
27
28
29
24
25
26
41
42
43
36
37
38
39
40
PART NAME
Light Switch
Door Lock& Key
Power Switch
Condensate Pan w/paper
Lower Grille Assembly
Caster Kit
Power Cord
Evaporator Coil
Defrost Limit Switch
Defrost Heater (115V)
Drain Heater (115V)
Drain Pan Heater (115V)
Evaporator Fan Guard
F23-S F49-S
PART No.
F72-S R23-S R49-S R72-S
146449 146449 146449 146449 146449 146449
146443 146443 146443 146443 146443 146443
146450 146450 146450 146450 146450 146450
146386 146387 146387 146386 146387 146387
146388 146389 146390 146388 146389 146390
100436 100436 100437 100436 100436 100437
138533 138533 161576 138533 138533 138533
146392 146394 146396 146391 146393 161569
146404 146404 146404 NA NA NA
146397 146398 146399
146403 146403 146403
146400 146401 146402
NA
NA
NA
NA
NA
NA
NA
NA
NA
146405 146405 146405 146405 146405 146405
Evaporator Fan Blade 146406 146406 146406 146406 146406 146406
Evaporator Fan Motor (115V) 146407 146407 146407 146407 146407 146407
Condenser Coil
Condenser Fan Blade
Condenser Fan Motor (115V) 146370 146370 146370 146370 146370 146370
Suction pipe(B) Assembly
Dryer
161567 161570 161570 161562 161562 161567
146371 146371 146371 146371 146371 146371
161568 161571 161574 161563 161563 161568
161564 161564 161575 161564 161564 161564
44
45
Compressor (115V) 150556 161572 161577 161565 161565 150556
46
47
Compressor Electrical Kit
Shelf
Shelf Kit(1Shelf + 4 Clips)
150557 161573 161578 161566 161566 150557
146446 146446
146446 146447 146446 146447
146448 146448
146516 146517
146516
146518
146516 146517
146516
146518
* Shelf: F(R) 72 - 146446 (ENDS), 146448 (CENTER)
* Shelf Kit: F(R) 72 - 146516 (ENDS), 146518 (CENTER)
* Cap. Tube: 161592(F23/49, R23/49/72), 161593(F72)
- 56 -
1-2. F23-S EXPLODED VIEW
- 57 -
1-3. F49-S EXPLODED VIEW
- 58 -
1-4. F72-S EXPLODED VIEW
- 59 -
1-5. R23-S EXPLODED VIEW
- 60 -
1-6. R49-S EXPLODED VIEW
- 61 -
1-7. R72-S EXPLODED VIEW
- 62 -
16
17
18
19
20
21
1
2
3
4
5
2-1. SERVICE LIST( F23/F49/F72-SH , R23/R49/R72-SH)
No. PART NAME
Door Hinge Kit - Top Right
PART No.
F23-SH F49-SH F72-SH R23-SH R49-SH R72-SH
146441 146441 146441 146441 146441 146441
6
Door Hinge Kit - Top Left
Door Hinge Kit - Lower Right
Door Hinge Kit - Lower Left
Door Hinge Kit - Lower Center
Control PCB Assembly (115V)
Used thru 12/2014
Control PCB Assembly (115V)
Universal (℉/℃) PCB
Main Transformer (115V)
NA
146412 146412 146412 146412 146412 146412
NA 146413 146413 NA 146413 146413
NA
146442 146442
NA 146414
NA
NA
146442 146442
NA 146414
146416 146417 146418 150313 150313 150313
150539 150540 150541 150538 150538 150538
146420 146420 146420 146420 146420 146420 7
8
9
10
11
11-1
12
13
DC Relay
Relay Wire Harness
Front PCB Wire Harness
Temperature Sensor use up to 12/2011
Sensor Kit (Includes
T-sensor and D-sensor)
Pilaster
146421 146421 146421 146421 146421 146421
146423 146423 146423 146423 146423 146423
146424 146424 146424 146424 146424 146424
NA NA NA 146425 146427 146429
146426 146428 146430 146426 146428 146430
146411 146411 146411 146411 146411 146411
146489 146489 146489 146489 146489 146489
14
14-1
15
15-1
Shelf Clip
Door Assembly - Upper Right
Hand
Door Assembly - Upper Left
Hand
Door Assembly – Lower Right
Hand
Door Assembly – Lower Left
Hand
Door Gasket
160501 160505 160510 160501 160505 160510
NA 160507 160512 NA 160507 160512
160502 160502 160511 160502 160502 160511
NA 160508 160513 NA 160508 160513
160503 160503 160514 160503 160503 160514
22
23
Lamp (115V)
Lamp Socket
Lamp Cover
Top Grille Assembly (115V)
Top Grill Cover - Right
Front PCB Assembly
Usedthru 12/2014
Front PCB Assembly
Universal (℉/℃) PCB
Control Decal
146408 146408 146408 146408 146408 146408
146409 146409 146409 146409 146409 146409
146410 146410 146410 146410 146410 146410
146433 146434 146435 146433 146434 146435
146431 146431 146431 146431 146431 146431
146419 146419 146419 146419 146419 146419
150537 150537 150537 150537 150537 150537
146432 146432 146432 146432 146432 146432
- 63 -
No.
33
34
35
30
31
32
27
28
29
24
25
26
41
42
43
36
37
38
39
40
44
45
PART NAME
Light Switch
Door Lock& Key
Power Switch
Condensate Pan w/paper
Lower Grille Assembly
Caster Kit
Power Cord
Evaporator Coil
Defrost Limit Switch
Defrost Heater (115V)
Drain Heater (115V)
Drain Pan Heater (115V)
Evaporator Fan Guard
Compressor (115V)
F23-SH F49-SH
PART No.
F72-SH R23-SH R49-SH R72-SH
146449 146449 146449 146449 146449 146449
146443 146443 146443 146443 146443 146443
146450 146450 146450 146450 146450 146450
146386 146387 146387 146386 146387 146387
146388 146389 146390 146388 146389 146390
100436 100436 100437 100436 100436 100437
138533 138533 161576 138533 138533 138533
146392 146394 146396 146391 146393 161569
146404 146404 146404 NA NA NA
146397 146398 146399
146403 146403 146403
146400 146401 146402
NA
NA
NA
NA
NA
NA
NA
NA
NA
146405 146405 146405 146405 146405 146405
Evaporator Fan Blade 146406 146406 146406 146406 146406 146406
Evaporator Fan Motor (115V) 146407 146407 146407 146407 146407 146407
Condenser Coil
Condenser Fan Blade
Condenser Fan Motor (115V) 146370 146370 146370 146370 146370 146370
Suction pipe(B) Assembly
Dryer
161567 161570 161570 161562 161562 161567
146371 146371 146371 146371 146371 146371
161568 161571 161574 161563 161563 161568
161564 161564 161575 161564 161564 161564
150556 161572 161577 161565 161565 150556
Compressor Electrical Kit 150557 161573 161578 161566 161566 150557
46
47
Shelf
Shelf Kit(1Shelf + 4 Clips)
146446 146447
146516 146517
146446
146448
146516
146518
146446 146447
146516 146517
146446
146448
146516
146518
48
49
Door Hinge Kit - Center Right 160504 160504 160504 160504 160504 160504
Door Hinge Kit - Center Left NA 160509
* Shelf: F(R) 72 - 146446 (ENDS), 146448 (CENTER)
* Shelf Kit: F(R) 72 - 146516 (ENDS), 146518 (CENTER)
160509
* Cap. Tube: 161592(F23/49-SH, R23/49/72-SH), 161593(F72-SH)
NA 160509 160509
- 64 -
2-2. F23-SH EXPLODED VIEW
- 65 -
2-3. F49-SH EXPLODED VIEW
- 66 -
2-4. F72-SH EXPLODED VIEW
- 67 -
2-5. R23-SH EXPLODED VIEW
- 68 -
2-6. R49-SH EXPLODED VIEW
- 69 -
2-7. R72-SH EXPLODED VIEW
- 70 -
3-1. SERVICE LIST (R23/R49/R72-G)
No. PART NAME
1
2
3
4
5
6
11-1
16
17
18
19
12
13
14
15
20
21
7
8
8A
9
10
10A
11
22
23
Door Hinge Kit - Top Right
Door Hinge Kit - Top Left
Door Hinge Kit - Lower Right
Door Hinge Kit - Lower Left
Door Hinge Kit - Lower Center
Control PCB Assembly (115V)
Used thru 12/2014
Control PCB Assembly (115V)
Universal (℉/℃) PCB
Main Transformer (115V)
DC Relay
LED DRIVER
Relay Wire Harness
Front PCB Wire Harness
LED Wire Harness
Temperature Sensor use up to 12/2011
Sensor Kit (Includes
T-sensor and D-sensor)
Pilaster
Shelf Clip
Door Assembly - Right Hand
Door Assembly - Left Hand
Door Gasket
LED (6W)
LED Fixture
LED wire cover
Top Grille Assembly
Top Grill Cover - Right
Front PCB Assembly
Used thru 12/2014
Front PCB Assembly
Universal (℉/℃) PCB
Control Decal
150538
146420
146421
160530
146423
146424
160529
146425
146426
146411
146489
160520
NA
160525
160526
160527
160528
160531
146431
146419
R23-G
160515
NA
160517
NA
NA
150313
150537
146432
- 71 -
150538
146420
146421
160530
146423
146424
160533
146427
146428
146411
146489
160521
160523
160525
160526
160527
160528
160534
146431
146419
PART No.
R49-G
160515
160516
160517
160518
NA
150313
150537
146432
150538
146420
146421
150571
146423
146424
160535
146429
146430
146411
146489
160522
160524
146482
160526
160527
160528
160536
146431
146419
R72-G
160515
160516
160517
160518
160519
150313
150537
146432
No. PART NAME
R23-G
40
41
42
43
44
37
38
39
45
46
47
32
33
34
35
36
29
30
31
24
24A
25
26
27
28
Light S/W Door Switch (rename)
Light Switch
Door Lock& Key
Power Switch
Condensate Pan w/paper
Lower Grille Assembly
Caster Kit
Power Cord
Evaporator Coil
Defrost Limit Switch
Defrost Heater (115V)
Drain Heater (115V)
Drain Pan Heater (115V)
Evaporator Fan Guard
Evaporator Fan Blade
Evaporator Fan Motor (115V)
Condenser Coil
Condenser Fan Blade
Condenser Fan Motor (115V)
Suction pipe(B) Assembly
Dryer
Compressor (115V)
Compressor Electrical Kit
Shelf
146449
160532
146443
146450
146386
146388
100436
138533
146391
NA
NA
NA
NA
146405
146406
146407
161562
146371
146370
161563
161564
161565
161566
146446
Shelf Kit(1Shelf + 4 Clips) 146516
* Shelf: F(R) 72 - 146446 (ENDS), 146448 (CENTER)
* Shelf Kit: F(R) 72 - 146516 (ENDS), 146518 (CENTER)
* Cap. Tube: 161592(R23/49/72-G)
- 72 -
PART No.
R49-G
146393
NA
NA
NA
NA
146405
146406
146407
146449
160532
146443
146450
146387
146389
100436
138533
161562
146371
146370
161563
161564
161565
161566
146447
146517
R72-G
161569
NA
NA
NA
NA
146405
146406
146407
146449
160532
146443
146450
146387
146390
100437
138533
161567
146371
146370
161568
161564
150556
150557
146446 / 146448
146516 / 146518
3-2. R23-G EXPLODED VIEW
- 73 -
3-3. R49-G EXPLODED VIEW
- 74 -
3-4. R72-G EXPLODED VIEW
- 75 -
2. MERCHANDISERS
1-1. SERVICE LIST (GR26H, GR48S, GR70H)
13-2
20
21
22
23
24
25
17
18
19
14
15
16
5
6
3
4
7
1
2
8
9
10
11
12-1
12-2
13-1
No. PART NAME
Door Hinge Kit - Top Right
Door Hinge Kit - Top Left
Door Hinge Kit - Lower Right
Door Hinge Kit - Lower Left
Door Hinge Kit - Lower Center
Ballast
Pilaster
Shelf Clip
Door Assembly - Right Hand
Door Assembly - Left Hand
Door Gasket
Advertising Panel Wire A
Advertising Panel Wire B
Interior Light Wire A
Interior Light Wire B
Lamp (115V)
Lamp Cover End
Lamp Cover
Advertising Panel - Blank
Advertising Panel Frame
Advertising Panel Frame-Left
Advertising Panel Frame-Right
Advertising Panel Frame-Bottom
Advertising Panel Frame-Top
Condensate Pan w/paper
Lower Grille Assembly
Foot Kit
NA
NA
146466 / 146467
146468
146469
146495
146497
NA
NA
NA
NA
146386
146463
146502
GR26H
146481
NA
146471
NA
NA
146491
146470
146489
146478
NA
146483
150190
NA
- 76 -
150526
150527
146466
146468
146469
146494
NA
146505
146506
146503
146504
146460
146462
146502
PART No.
GR48S
NA
NA
NA
NA
NA
146491
146470
146489
146477
146480
NA
150524
150525
NA
NA
NA
NA
NA
146493
NA
146500
146501
146498
146499
146387
146461
146502
GR70H
160515
160516
160517
160518
160519
NA
146411
146489
161582
161584
146482
NA
NA
No. PART NAME
36
37
38
31
32
33
34
35
39
40
41
42
26
27
28
29
30
Power Cord
Evaporator Coil
Evaporator Fan Guard
Evaporator Fan Blade
Evaporator Fan Motor
Temperature Control
Light Switch
Capillary Tube
Suction pipe(B) Assembly
Dryer
Condenser Coil
Condenser Fan Blade
Condenser Fan Moto
Compressor
Compressor Electrical Kit
Shelf
Shelf Kit(1Shelf + 4Clips)
43
44
45
SMPS (60W)
LED (20W)
LED (6W)
NA
NA
NA
46 LED Fixture NA
47 LED wire cover
* Shelf: GR48S - 146486 (LEFT), 146487 (RIGHT)
NA
* Shelf Kit: GR48S - 146521 (LEFT), 146522 (RIGHT)
GR70H - 161586 (ENDS), 161588 (CENTER)
* Cap. Tube: 161592(GR70H)
- 77 -
GR26H
146475
146465
146405
146406
146407
146474
146450
146458
146457
146384
146372
146371
146370
146452
146454
146488
146523
146473
146450
NA
146456
146384
146455
146371
146370
PART No.
GR48S
146475
146464
146405
146406
146407
146451
146453
146486 / 146487
146521 / 146522
NA
NA
NA
NA
NA
GR70H
138533
161569
146405
146406
146407
146472
146450
NA
161568
161564
161567
146371
146370
150556
150557
NA / NA
161586 / 161588
161580
161581
160526
160527
160528
1-2. GR26H EXPLODED VIEW
- 78 -
1-3. GR48S EXPLODED VIEW
- 79 -
1-4. GR70H EXPLODED VIEW
- 80 -
D. COMPRESSOR & ACCESSORIES CHECK LIST
1. F23-S/SH, R72-G, R72-S/SH, GR70H - - - - - - - - - - - - - - - - - - - - D2
2. F49-S/SH - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D3
3. F72-S/SH - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D4
4. R23/R49-S/SH, R23/49-G - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D5
5. GR26H - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D6
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D7 6. GR48S
- 81 -
1. F23-S/SH, , R72-S/SH/G, GR70H
① Compressor Spec. : NEK2150GK (R-404A), 115V/60Hz, CSR Type
② Maker : EMBRACO
③ Cooling Capacity : 628kcal/Hr - LBP
④ Starting Capacitor Spec. : 189~227 ㎌ / 165V
⑤ Running Capacitor Spec. : 25 ㎌ / 400V
⑥ Relay Spec. : RVA9AD3C-121
⑦ O.L.P Spec. : T0873/G9
OLP
EARTH
3
C
S
M
* Comp. Winding Resistance: C - M → 0.77Ω, C - S → 4.5Ω (RT 25 ℃( 77℉))
* O.L.P Winding Resistance: 3- C → 0 Ω (OK), ∞ Ω (NG)
* Relay Winding Resistance: 1 -2 → 0 Ω (OK), ∞ Ω (NG)
BLACK
WIRE
WIRE
WHITE
2
1
< COMP. Wiring Diagram>
- 82 -
2. F49-S/SH
① Compressor Spec. : NT2178GKV (R-404A), 115V/60Hz, CSR Type
② Maker : EMBRACO
③ Cooling Capacity : 903kcal/Hr - LBP
④ Starting Capacitor Spec. : 243~292 ㎌ / 165V
⑤ Running Capacitor Spec. : 35 ㎌ / 400V
⑥ Relay Spec. : RVA9AD3C-121
⑦ O.L.P Spec. : MST18RN-3041
S
C
3
M
EART
OL
* Comp. Winding Resistance: C - M → 0.40Ω, C - S → 2.60Ω (RT 25 ℃( 77℉))
* O.L.P Winding Resistance: 3 - C → 0 Ω (OK), ∞ Ω (NG)
* Relay Winding Resistance: 1 - 2 → 0 Ω (OK), ∞ Ω (NG)
BLACK
WIRE
WIRE
WHITE
2
1
- 83 -
< COMP. Wiring Diagram>
3. F72-S/SH
① Compressor Spec. : NT2192GKV (R-404A), 115V/60Hz, CSR Type
② Maker : EMBRACO
③ Cooling Capacity : 1,051kcal/Hr - LBP
④ Starting Capacitor Spec. : 243~292 ㎌ / 165V
⑤ Running Capacitor Spec. : 35 ㎌ / 400V
⑥ Relay Spec. : RVA2AE3C-105
⑦ O.L.P Spec. : CRA1773-3029 GA3RMU0002
S
C
M
OL
3
EART
* Comp. Winding Resistance: C - M → 0.34Ω, C - S → 2.59Ω (RT 25 ℃( 77℉))
* O.L.P Winding Resistance: 3 -
C → 0 Ω (OK), ∞ Ω (NG)
* Relay Winding Resistance: 1 - 2 → 0 Ω (OK), ∞ Ω (NG)
BLACK
WIRE
WIRE
WHITE
2
1
- 84 -
< COMP. Wiring Diagram>
4. R23/R49-S/SH, R23/R49-G
① Compressor Spec. : NW108LHB1 (R-134a), 115V/60Hz, CSR Type
② Maker : DAEWOO-KOREA
③ Cooling Capacity : 325kcal/Hr - LBP
④ Starting Capacitor Spec. : 125 ㎌ / 200V
⑤ Running Capacitor Spec. : 16 ㎌ / 250V
⑥ Relay Spec. : R6R8MD22SS
⑦ O.L.P Spec. : 4TM801SFBZZ-52
C(C-1)
C-1
3 2
S(6) M(5)
< COMP. Terminal >
< OLP >
1
5
< RELAY >
C-1 OLP
3
2
RELAY
1
< COMP. Wiring Diagram>
* Comp. Winding Resistance: C - M → 1.20Ω, C - S → 6.18Ω(RT 25℃,77℉)
* O.L.P Winding Resistance: 1 - 11 → 0 Ω (OK), ∞ Ω (NG)
On/Off Temperature - O/T: 135 ℃, C/T: 61℃
* Relay Winding Resistance: M (5) – C-1 → 0 Ω (OK), ∞ Ω (NG)
S (6) – C-1 → ∞ Ω (OK)
* PTC: 6.8
Ω
- 85 -
6
6. GR26H
① Compressor Spec. : SK182C-L2U (R-134a), 115V/60Hz, RSCR Type
② Maker : SAMSUNG-KOREA
③ Cooling Capacity : 243kcal/Hr - LBP
④ Relay Spec. : PTHAR-T4R7M180D/J531Q32E4R7M1802
⑤ O.L.P Spec. : 4TM444NHBYY-53
C(1)
2 3
1
S(6)
M(5)
5
6
1-1
< Comp. Terminal > < RELAY
>
< OLP >
* Comp. Winding Resistance: C - M → 2.3Ω, C - S → 3.8Ω (RT 25 ℃(77 ℉))
* O.L.P Winding Resistance: 1 - 11 → 0 Ω (OK), ∞ Ω (NG)
* Relay Winding Resistance: 5 - 6 → 0 Ω (OK), ∞ Ω (NG)
2 - 3 → 0 Ω (OK), ∞ Ω (NG)
* Measuring the resistance, the bottom of the relay must be downward (like fig.1)
Fig.1
3
1
OLP
2
RELAY
< COMP. Wiring Diagram>
- 86 -
7. GR48S
① Compressor Spec. : CAJ4476Y (A) (R-134a), 115V/60Hz, CSIR Type
② Maker : TECUMSEH-FRANCE
③ Cooling Capacity : 1,946kcal/Hr - HBP
④ Starting Capacitor Spec. : 250 ㎌ / 160V
⑤ Relay Spec. : 3ARR3*2M*
⑥ O.L.P Spec. : CRA38014
C
OLP
S
M
3
S/C
Earth
< RELAY BOX >
* Comp. Winding Resistance: C - M → 0.72Ω, C - S → 3.68Ω (RT 20 ℃( 68℉))
* O.L.P Winding Resistance: 3 -
C → 0 Ω (OK), ∞ Ω (NG)
* Relay Winding Resistance: 1 - 2 → 0 Ω (OK), ∞ Ω (NG)
Black wire
RELAY
2
White wire
1
2
1
2N
3L
4
5
S/C
1
AC115V
60Hz
OLP
S
3
C
< COMP. Wiring Diagram>
M
- 87 -
advertisement
Related manuals
advertisement