TECHNICAL MANUAL

Add to My manuals
87 Pages

advertisement

TECHNICAL MANUAL | Manualzz

TECHNICAL MANUAL

FREEZER : F23-S, F23-SH

F49-S, F49-SH

F72-S, F72-SH

REFRIGERATOR : R23-S, R23-SH, R23-G

R49-S, R49-SH, R49-G

R72-S, R72-SH, R72-G

MERCHANDISERS : GR26H, GR48S, GR72H

- 1 -

A. GENERA L

1. SPECIFICATION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A3

1) GENERAL

2) MAIN COMPONENTS

2. REFRIGERATION CYCLE - - - - - - - - - - - - - - - - - - - - - - - - - - A9

3. TROUBLE SHOOTING - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A11

1) CHECKING THE POWER SUPPLY

2) CHECKING THE POWER SUPPLY OF CONTROL BOARD

3) CHECKING THE CONTROL PART OF REFRIGERATION CYCLE

4) CHECKING THE DEFROST PART

5) WHEN THE UNIT DOES NOT COOL

6) WHEN THERE IS A ABNORMAL NOISE

7) WHEN THE TEMPERATURE DOES NOT DISPLAY

8) WHEN THE LAMP DOES NOT LIGHT

9) CHECKING SENSOR

4. FEATURE CHART - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A22

5. WIRING DIAGRAM - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A28

6. REPLACEMENT OF COMPONENTS - - - - - - - - - - - - - - - - - - A37

- 2 -

1. SPECIFICATION

1.1 GENERAL - SOLID DOOR FREEZER & REFRIGERATOR (FULL DOOR / HALF DOOR)

PRODUCT

MODEL

Capacity

Net Capacity

Exterior Dimension (W)

(Including casters

Door Handles)

(D)

(H)

Interior Dimension

Product Weight

Door Type

(W)

(D)

(H)

SOLID (FULL/HALF) DOOR

FREEZER

F23-S /

F23-SH

650 ℓ(23ft

3 )/

648 ℓ(22.9ft

3 )

552 ℓ(19.5ft

3 )/

551 ℓ(19.4ft

3 )

695

(27.4”)

F49-S /

F49-SH

1,385 ℓ(49ft

3 )/

1,381 ℓ(48.8ft

3 )

1,195 ℓ(42.2 ft

3 )/

1,191 ℓ(42.1 ft

3 )

1,400

(55.2”)

SOLID (FULL/HALF) DOOR

F72-S /

F72-SH

2,035 ℓ(72ft

3 )/

2,028 ℓ(71.6ft

3 )

1,790 ℓ(63.2ft

3 )/

1,782 ℓ(63ft

3 )

R23-S /

R23-SH

650 ℓ(23ft

3 )/

648 ℓ(22.9ft

3 )

552 ℓ(19.5ft

3 )/

551 ℓ(19.4ft

3 )

1,980

(78.0”)

838

㎜ (33”)

695

(27.4”)

REFRIGERATOR

R49-S /

R49-SH

1,385 ℓ(49ft

3 )/

1,381 ℓ(48.8ft

3 )

2,035 ℓ(72ft

3 )/

2,028 ℓ(71.6ft

3 )

1,195 ℓ(42.2 ft

3 )/

1,191 ℓ(42.1 ft

3 )

1,790 ℓ(63.2ft

3 )/

1,782 ℓ(63ft

3 )

1,400

(55.2”)

R72-S /

R72-SH

1,980

(78.0”)

600

(23.6

”)

124

㎏(273 lb)/

126

㎏(278 lb)

Swing 1EA/

Swing 2EA

1,305

(51.4

”)

194

㎏(428 lb)/

198

㎏(437 lb)

Swing 2EA/

Swing 4EA

2,127

㎜ (83.7”)

1,885

(74.2

”)

635

㎜ (25”)

600

(23.6

”)

1,545

㎜ (60.8”)

255

㎏(562 lb)/

260

㎏(573 lb)

121

㎏(267 lb)/

123

㎏(271 lb)

Swing 3EA/

Swing 6EA

Swing 1EA/

Swing 2EA

1,305

(51.4

”)

1,885

(74.2

”)

186

㎏(410 lb)/

190

㎏(419 lb)

253

㎏(558 lb)/

258

㎏(569 lb)

Swing 2EA/

Swing 4EA

Swing 3EA/

Swing 6EA

Door Material Stainless steel (STS)

Shelves 4EA 8EA 12EA 4EA 8EA 12EA

Power Voltage AC 115V/60Hz

Plug in - Installation

Amps

Compressor

Refrigerant

Range of Temperature

Door auto-close equipment

Door stop

NEMA 5-15P

8.5A

3/5HP

10.5A

4/5HP

NEMA 5-20P

12.0A

1HP

7.5A

1/3HP

NEMA 5-15P

7.5A

1/3HP

10.0A

3/5HP

250 g

(8.8 oz)

R-404A

340 g

(12.0 oz)

Below -18℃ (0°F)

400 g

(14.1 oz)

210 g

(7.4 oz)

R-134a

220 g

(7.8 oz)

R-404A

300 g

(10.6 oz)

0℃ ~ 4℃ (+32°F ~ +40°F)

Auto-close for Spring

120˚ Stop

Air suction equipment

Caster 4” × 4EA

Air damper

4” × 6EA 4” × 4EA

Condensing unit Sliding Type

◈ Above specifications are subjected to change without prior notice for quality improvement.

◈ The nameplate(includes Serial Number) is located on the upper left of the cabinet interior.

- 3 -

4” × 6EA

Type of Condenser

Condenser pipe

Diameter

Condenser Fan Motor

Dryer

Temperature Control

Running Indication

Interior Temp.

Indication

Interior Lamp

(Incandescent lamp)

Defrost for evaporator

Defrost sheath heater

Defrost pan heater

Drain heater

Door switch

Power switch

1.2 MAIN COMPONENTS - SOLID DOOR FREEZER & REFRIGERATOR

PRODUCT

MODEL

SOLID (FULL/HALF) DOOR

FREEZER

F23-S /

F23-SH

F49-S /

F49-SH

F72-S /

F72-SH

NEK2150GK

(Embraco)

NT2178GKV

(Embraco)

NT2192GKV

(Embraco)

Compressor

(Manufacture)

Compressor

Capacity(kcal/h)

Type of Compressor motor

LBP 628 LBP 903 LBP 1051

SOLID (FULL/HALF) DOOR

REFRIGERATOR

R23-S /

R23-SH

R49-S /

R49-SH

R72-S /

R72-SH

NW108LHB1

(DAEWOO-Korea)

NEK2150GK

(Embraco)

LBP 325 LBP 628

Compressor O.L.P

Compressor Relay

Starting Capacitor

Running Capacitor

T0873/G9

MST18RN-

3041

RVA9AD3C-121

189~227 ㎌

/ 165V

25 ㎌ / 400V

CSR

CRA1773-

3029

GA3RMU0002

RVA2AE3C-105

243~292 ㎌

/ 165V

35 ㎌ / 400V

4TM801SFBZZ-52

R6R8MD22SS

125 ㎌ / 200V

16 ㎌ / 250V

T0873/G9

RVA9AD3C-121

189~227 ㎌

/ 165V

25 ㎌ / 400V

Type of Evaporator

Evaporator pipe

Diameter

Cooling Fan Motor

9.52mm (3/8")

Cu pipe + Al fin + Blue color coating

12.7mm

(1/2 ”)

IS3225LTSA, 120V/60Hz

9.52mm (3/8")

Cu pipe + Al fin

7.00mm (0.28")

MA7425W1, 120V/60Hz

OD 25.4mm (1"), XH-9, 30g(1.06oz)

Thermistor

Digital Display

Digital Display

40W × 1EA 40W × 2EA 40W × 1EA

Heated defrost (Control of thermistor)

450W 670W 944W

60W 128W 90W

9W

SP201R-7DR, AC125V

SL112A, AC125V/12A

Off cycle

-

-

-

40W × 2EA

- 4 -

2.1 GENERAL - GLASS DOOR REFRIGERATOR

PRODUCT GLASS (FULL) DOOR REFRIGERATOR

MODEL

Capacity

Net Capacity

Exterior Dimension

(Including casters

Door Handles)

Interior Dimension

Product Weight

Door Type

Door Material

Shelves

Power Voltage

Plug in - Installation

Amps

Compressor

Refrigerant

(W)

(D)

(H)

(W)

(D)

(H)

Range of Temperature

Door auto-close equipment

Door stop

Air suction equipment

Caster

R23-G

650 ℓ

(23 ft 3 )

552 ℓ

(19.5 ft 3 )

695

(27.4”)

600

(23.6

126

”)

(278 lb)

Swing 1EA

4EA

R49-G

1,385 ℓ

(49 ft 3 )

1,195 ℓ

(42.2 ft 3 )

1,400

(55.2”)

835

㎜ (32.9”)

2,127

㎜ (83.7”)

1,305

(51.4

”)

635

㎜ (25”)

1,545

㎜ (60.8”)

200

(441 lb)

Swing 2EA

Glass + Al(A6063S)

8EA

AC 115V/60Hz

NEMA 5-15P

7.5A

1/3HP

7.5A

1/3HP

R-134a

230 g

(8.1 oz)

R-134a

230 g

(8.1 oz)

0℃ ~ 4℃ (+32°F ~ +40°F)

Auto-close for Spring

120˚ Stop

Air damper

4” × 4EA

R72-G

2,035 ℓ

(72 ft 3 )

1,790 ℓ

(63.2 ft 3 )

1,980

(78.0”)

1,885

(74.2

”)

271

(597 lb)

Swing 3EA

12EA

8.5A

3/5HP

R-404A

330 g

(11.6 oz)

4” × 6EA

Condensing unit Sliding Type

◈ Above specifications are subjected to change without prior notice for quality improvement.

◈ The nameplate(includes Serial Number) is located on the upper left of the cabinet interior.

- 5 -

2.2 MAIN COMPONENTS - GLASS DOOR REFRIGERATOR

PRODUCT GLASS (FULL) DOOR REFRIGERATOR

MODEL

Compressor

(Manufacture)

Compressor Capacity(kcal/h)

Type of Compressor motor

Compressor O.L.P

Compressor Relay

Starting Capacitor

Running Capacitor

Type of Evaporator

Evaporator pipe Diameter

Cooling Fan Motor

Type of Condenser

Condenser pipe Diameter

Condenser Fan Motor

Dryer

Temperature Control

Running Indication

Interior Temp. Indication

Interior Lamp (LED)

Defrost for evaporator

Defrost sheath heater

Defrost pan heater

Drain heater

Door switch

Power switch

Light switch

R23-G

NW108LHB1

(DAEWOO-Korea)

LBP 325

R49-G

CSR

4TM801SFBZZ-52

R6R8MD22SS

R72-G

NEK2150GK

(Embraco)

LBP 628

T0873/G9

RVA9AD3C-121

125 ㎌ / 200V

16 ㎌ / 250V

189~227 ㎌ / 165V

25 ㎌ / 400V

Cu pipe + Al fin + Blue color coating

9.52mm (3/8")

IS3225LTSA, 120V/60Hz

Cu pipe + Al fin

7.00mm (0.28")

MA7425W1, 120V/60Hz

OD 25.4mm (1"), XH-9, 30g(1.06oz)

Thermistor

Digital Display

Digital Display

6W x 1EA 6W x 2EA

Off cycle

-

-

-

SP201R-7DR, AC125V

SL112A, AC125V/12A

RL1-3, 16A/250V, ON-OFF

6W x 3EA

- 6 -

3.1 GENERAL - MERCHANDISERS

PRODUCT MERCHANDISERS

MODEL

Capacity

Net Capacity

Exterior Dimension

(Including casters

Door Handles)

Interior Dimension

Net Weight

Door Type

Door Material

Shelves

Power Voltage

Plug in - Installation

Amps

Compressor

(W)

(D)

(H)

(W)

(D)

(H)

Refrigerant

Range of Temperature

Door auto-close equipment

Door stop equipment

Air suction equipment

Caster

Condensing unit

Door switch

Power(or Lamp) switch

GR26H

736 ℓ (26 ft

3 )

677 ℓ (23.9 ft

3 )

720

㎜ (28.4”)

844

㎜ (33.3”)

2,017

㎜ (79.4”)

640

㎜ (25”)

719

㎜ (28.3”)

1,584

㎜ (62.4”)

130

㎏ (287 lb)

Swing 1EA

Glass + PVC

4EA

3.9A

1/4 HP

GR48S

1359 ℓ (48 ft

3 )

1339 ℓ (47.3 ft

3 )

1,350

㎜ (53.2”)

780

㎜ (30.7”)

2,012

㎜ (79.2”)

1,280

㎜ (50.4”)

642

㎜ (25.3”)

1,562

㎜ (61.5”)

215

㎏ (474 lb)

Sliding 2EA

Glass + PVC

8EA

AC 115V/60Hz

NEMA 5-15P

10.0A

1/2 HP

R-134a

300g (10.6 oz) 460g (16.2 oz)

Auto-close for Spring

120˚ Stop

0℃ ~ 4℃ (32℉ ~ 40℉)

Auto-close for slope

-

-

Adjust foot 4EA

-

Adjust foot 6EA

-

Sliding Type

-

SL112A, AC125V/12A

GR70H

1982 ℓ (70 ft

3 )

1877 ℓ (66.3 ft

3 )

1,980

㎜ (78”)

835

㎜ (32.9”)

2,126

㎜ (83.7”)

1,885

㎜ (74.2”)

635

㎜ (25”)

1,545

㎜ (60.8”)

325

㎏ (716 lb)

Swing 3EA

Glass + Al

12EA

10.0A

3/5 HP

R-404A

360g (12.7 oz)

Auto-close for Spring

120˚ Stop

Air damper

Adjust foot 6EA

-

◈ Above specifications are subjected to change without prior notice for quality improvement.

◈ The nameplate(includes Serial Number) is located on the upper left of the cabinet interior.

- 7 -

3.2 MAIN COMPONENTS - MERCHANDISERS

PRODUCT MERCHANDISERS

MODEL

Compressor

(Manufacture)

Compressor Capacity(kcal/h)

Type of Compressor motor

Compressor O.L.P

Compressor Relay

Starting Capacitor

Running Capacitor

Type of Evaporator

Evaporator pipe Diameter

Cooling Fan Motor

Type of Condenser

Condenser pipe Diameter

Condenser Fan Motor

Dryer

Temperature Control

Running Indication

Interior Temp. Indication

Interior Lamp

(Fluorescent lamp)

Ad. Panel Fluorescent Lamp

Ballast

Ballast Name

(Manufacture)

SMPS

SMPS Name

(Manufacture)

Defrost for evaporator

Defrost sheath heater

Defrost pan heater

Drain heater

GR26H

SK182C-L2U

(SAMSUNG)

LBP 256

RSCR

4TM444NHBYY

J531Q32E4R7M1802

-

12 ㎌/250V

GR48S

CAJ4476Y(A)

(Tecumseh-France)

HBP 1946

CSIR

CRA38014

3ARR3*2M*

250 ㎌/160V

-

GR70H

NEK2150GK

(Embraco)

LBP 628

CSR

T0873/G9

RVA9AD3C-121

189~227 ㎌

/ 165V

25 ㎌ / 400V

Cu pipe + Al fin

9.52 mm (3/8")

IS3225LTSA, 120V/60Hz

Cu pipe + Al fin

9.52 mm (3/8")

MA7425W1, 120V/60Hz

Thermostat

(GNF-250L)

OD 25.4mm (1"), XH-9, 30g(1.06oz)

Thermostat

(GNF-240L)

-

-

7.00mm (0.28")

Thermostat

(GNF-246L)

32W × 1EA

20W × 1EA

32W(Double)×1EA

B232I120RH-A

(ADVANCE)

-

-

-

-

-

32W × 1EA

32W × 1EA

32W(Double)×1EA

B232I120RH-A

(ADVANCE)

-

-

Off cycle

-

-

-

6W(LED) × 3EA

20W(LED) × 1EA

-

-

60W(DC12V)

LVP-60-12

(MEAN WELL)

-

-

-

- 8 -

2. REFRIGERATION CYCLE

Mechanical refrigeration is accomplished by continuously circulating, evaporating, and condensing a fixed supply of refrigerant in a closed system. Evaporation occurs at allow temperature and pressure while condensation occurs at high temperature and pressure. Thus it is possible to transfer heat fom an area of low temperature (i.e., refrigerated compartment) to an area of high temperature (i.e., surrounding of refrigerator).

CONDENSER

CAPILLARY TUBE

COMPRESSOR

EVAPORATOR

THE BASE REFRIGERATION CYCLE

Beginning the cycle at the evaporator inlet the low pressure liquid expands, absorbs heat (so refrigerator inner-cabinet is cooled), and evaporates, changing to allow low pressure gas at the evaporator outlet.

The compressor pumps this gas from the evaporator, increases its pressure, and discharges the high pressured- temperature gas to the condenser.

The condenser lets high pressured- temperature gas emit the heat (so surrounding of the condenser is warmed) in order to make it condense.

The capillary tube prevents high pressured- temperature liquid from entering the evaporator in order to lower the pressure in the evaporator and control the flow of refrigerant into the evaporator automatically.

Eventually the desired air temperature in refrigerator inner-cabinet is reached, the thermostat (temperature controller) will break the electrical circuit to the compressor motor and stop the compressor.

- 9 -

As the temperature of the air rises, the thermostat (or controller) remakes the electrical circuit. The compressor starts, and cycle continues.

The schematic refrigeration (or freezing) cycle of F23/F49/F72/R23/R49/R72/GR26/GR48/GR70 is like below.

MODEL COMPRESSOR

F23-S/SH, R72-G,GR70H NEK2150GK

F49-S/SH

F72-S/SH

R23/R49-S/SH,R23/R49-G

R72-S/SH

GR26H

GR48S

NT2178GKV

NT2192GKV

NW108LHB1

CAJ4461Y(A)

SK182C-L2U

CAJ4476Y(A)

No.

1

2

Part Name

COMPRESSOR

CONDENSER

7

8

9

5

6

3

4

EVAPORATOR

DRYER

ACCUMULATOR

DISCHARGE PIPE

DRYER CONNECT PIPE

CAPILLARY TUBE

SUCTION PIPE (INNER-CABINET)

10 SUCTION PIPE (COMPRESSOR)

11 CHARGE PIPE (COMPRESSOR)

12 CHARGE PIPE (DRYER)

Description

C1220TS-O,H

C1220TS-O,H

C1220T-H

C1220T-1/4H

C1220T-O

C1220T-O

C1220T-H

C1220T-O

C1220T-O

C1220T-O

C1220T-O

Remark

- 10 -

3. TROUBLESHOOTING

1) CHECKING THE POWER SUPPLY

① F23 / F49 / F72 / R23 / R49 / R72 ② GR26H / GR48S / GR70H

Is the power cord

Plugged in?

YES

NO

Plug in

Is the power cord

Plugged in?

YES

NO

Plug in

Is the rated voltage supplied?

YES

NO

Correct

Is the rated voltage supplied?

YES

NO

Correct

Is the power cord normal?

YES

NO

Defective power cord

Is the power switch

“OFF” position?

YES

NO

NORMAL

Move to “ON” position

- 11 -

Is the power cord normal?

YES

NO

Defective power cord

NORMAL

2) CHEKING THE POWER SUPPLY OF CONTROL BOARD

① F23 / F49 / F72 / R23 / R49 / R72

Is the rated voltage supplied to the C/B?

YES

NO

Check wiring

Does the fuse fail?

YES

Defective fuse

NO

NOTES

* C/B: Control Board

(Printed Circuit Board)

* Fuse Spec: AC250V, 8A

* Transformer Spec.

Primary: AC115V

Secondary: AC12V (Red wire)

AC20V (Blue wire)

Is the coil winding of transformer open?

YES

NO Defective transformer

Is the secondary output volt, of trans, normal

NO

Defective transformer

YES

Is the DC 24V supplied to coil part in relay?

NO

Check C/B

YES

- 12 -

Does the contact part in relay continue?

YES

NORMAL

NO

Defective

Relay

3) CHECKING THE CONTROL PART OF REFRIGERATION CYCLE

① F23 / F49 / F72 / R23 / R49 / R72

Check the power supply

Is the to comp. connected properly?

NO

Correct

Are the sensors in

C/B connected properly?

NO

Correct

YES

YES

Check the resistance of T-Sensor

NO

Defective

T-sensor

& OLP in comp. assembled properly?

Correct

YES

YES

Is the temp. displayed in D/B properly?

NO

Defective

MICOM

Check the continuity of OLP in compressor

NO

Defective

OLP

YES

YES

Check the temperature set point

Check the continuity of relay in compressor

YES

NO

Defective relay

YES

Defective compressor

NO

Temperature resetting

Check the power supply of control board

NOTES

* C/B: Control Board

* D/B: Display Board

* OLP: Over load Protector

- 13 -

② GR26H / GR48S / GR70H

Check the power supply

When the thermostat is OFF.

Does the comp. run?

NO

YES

Defective thermostat

Is the to comp. connected properly?

NO

YES

Correct

& OLP in comp. assembled properly?

YES

Check the continuity of OLP in compressor

NO

Defective OLP

YES

Correct

Check the continuity of relay in compressor

NO

Defective relay

YES

Defective compressor

- 14 -

4) CHECKING THE DEFROST PART

① F23 / F49 / F72

Check the power supply

Do the B/M and D-

Sensor located in place?

NO

Correct

YES

Do the wiring to the heater and B/M connected properly?

NO

Check wiring

YES

Check the resistance of

D-sensor

YES

NO

Defective

D-Sensor

Does the B/M continue below

41℉(5℃)

YES

NO

Defective

Bi-Metal

Dose the defrost output on C/B normal in defrost mode?

NO Defective

Control Board

YES

Defective MICOM

Are the defrost heaters normal?

NO

Defective heater

YES

NOTES

* C/B: Control Board

* B/M: Bi-Metal

(Temp. Limiting Controller)

- 15 -

② R23 / R49 / R72

Check the power supply

Do the D-Sensor located in place?

NO

Correct

YES

Check the resistance of

D-sensor

YES

NO

Defective

D-Sensor

Dose the defrost output on C/B normal in defrost mode?

NO

Defective

Control Board

YES

Defective micom

NOTES

* C/B: Control Board

- 16 -

5) WHEN THE UNIT DOES NOT COOL

① All Models

Does the compressor run normally?

NO

Check the control part of refrigeration cycle

YES

Is the unit located in a level place?

YES

NO

Correct

Is the temperature set point proper?

NO

Temperature resetting

YES

Are the goods loaded properly?

NO

Correct

YES

Does the cool air leak?

YES

Check door gasket

NO

Does the frost form excessively in evaporator?

YES

Freezer: Check the defrost part

NO

Refrigerator: forced defrost dust on condenser fin?

NO

Clean

Does the cond.

NO

(eva.) fan motor rotate normally?

Defective motor, fan

YES

Does the refrigerant leak?

YES

Correct

NO

Is the refrigerant line restricted?

YES

Correct

NO

Excluding GR26H, GR48S

GR70H

Is the contact of door switch normal?

NO

Defective door switch

YES

When door closed.

Are the door S/We pushed by the top of door?

NO

Apply spacer between door switch and the top of door

YES

Check compressor

- 17 -

6) WHEN THERE IS A ABNORMAL NOISE

① All Models

Is the unit located in a level place?

YES

NO

Correct

Is the high voltage supplied?

YES

Adjust voltage

NO

Are the pipes rattled?

YES Reform to be free of contact

NO

Are the parts assembled tightly?

NO

Tighten

YES

- 18 -

Are the fans bent?

YES

Defective fan

NO

Do the fans rotate well?

NO

Defective fan, motor

YES

Is there any noise in motor?

YES

Defective motor

NO

Comp. is running but the unit does not cool

YES

7) WHEN THE TEMPERATURE DOES NOT DISPLAY

① F23 / F49 / F72 / R23 / R49 / R72

Check the power supply

Check the power supply in control board

Is the connect ion between C/B and D/B properly?

NO

Tighten

YES

Is the micom inserted on C/B properly?

YES

Replace display board

NOTES

* C/B: Control Board

* D/B: Display Board

NO

Tighten

- 19 -

8) WHEN THE LAMP DOES NOT LIGHT

① F23 / F49 / F72 / R23 / R49 / R72 ② GR26H / GR48S / GR70H

Check the power supply

Check the power supply

Check the connecting points with socket

YES

Adjust the lamp for good connection

Is the lamp defective?

YES

NO

Defective lamp

Check the continuity of lamp switch

YES

NO

Defective lamp switch

When door closed.

Are the door S/We pushed by the top of door?

NO

Apply spacer between door switch and the top of door

YES

Check wiring

Check the connecting points with socket

NO

Adjust the lamp for good connection

YES

Is the lamp defective?

YES

NO

Defective lamp

Check the continuity of lamp switch

YES

NO

Defective lamp switch

Check the continuity of ballast

YES

Check wiring

NO

Defective ballast

* Incandescence Lamp: 40W * Fluorescent Lamp: 32W

- 20 -

9) CHECKING SENSOR

Sensor assembly consists of T-sensor (lead wire: orange) and D-sensor (lead wire: blue).

The T-sensor is used for cabinet temperature control and the D-sensor is used for defrost control.

The resistance of the sensor varies depending on temperature.

If you Immerse the sensor in a glass containing ice water for 2 minutes and then check for the resistance between sensor leads, the normal reading is 7.88 ㏀ (T-sensor) / 30 ㏀ (D-sensor).

Temperature (℉/℃)

-5 / -21

0 / -18

10 / -12

23 / -5

32 / 0

41 / 5

50 / 10

60 / 16

70 / 21

T-sensor (±6.5%)

Resistance (㏀)

D-sensor (±5.5%)

23.04

19.76

14.65

10.10

7.88

6.20

7.91

3.82

3.00

79.17

68.92

52.61

37.55

30.00

24.13

19.53

15.56

12.48

- 21 -

4. FEATURE CHART

1) F23/R23-S

2) F49/R49-S

- 22 -

3) F72/R72-S

4) F23/R23-SH

- 23 -

5) F49/R49-SH

6) F72/R72-SH

- 24 -

7) R23-G

8) R49-G

- 25 -

9) R72-G

10) GR26H

AD. Panel

Door (Glass)

Door handle

BALLAST

AD. PANEL

FAN COVER

COOLING FAN

COOLING FAN MOTOR

EVAPORATOR

LAMP

COVER LAMP

DOOR FRAME

WATER COLLECTOR

DRAIN HOSE

LAMP

SHELF SUPPORT

SHELF

DOOR HANDLE

Lower grille

Adjust foot

[ Front view ]

LOWER GRILLE

CONDENSER

CONDENSER FAN MOTOR MOTOR BRKT COMPRESSOR

[ Side view ]

DRYER

SUCTION PIPE

- 26 -

11) GR48S

AD. Panel

Door (Glass)

Door handle

Lower grille

Adjust foot

[ Front view ]

COOLING FAN COVER

BALLAST

AD. PANEL

LAMP

COOLING FAN

LAMP

LAMP TUBE

COOLING FAN MOTOR

EVAPORATOR

WATER COLLECTOR

DRAIN HOSE

SHELF SUPPORT

SHELF

DOOR HANDLE

DOOR FRAME

CENTER POST

LOWER GRILL

CONDENSER

CONDENSER FAN MOTOR

MOTOR BRKT

COMPRESSOR

[ Side view ]

DRIER

SUCTION PIPE

12) GR70H

- 27 -

5. WIRING DIAGRAMS

1) F23-S

2) F49-S

- 28 -

3) F72-S

4) R23-S

- 29 -

5) R49-S

6) R72-S

- 30 -

7) R23-SH

8) R49-SH

- 31 -

9) R72-SH

10) F23-SH

- 32 -

11) F49-SH

12) F72-SH

- 33 -

13) R23-G

6) R49-G

- 34 -

6) R72-G

7) GR26H

- 35 -

8) GR48S

9) GR70H

- 36 -

6. REPLACEMENT OF COMPONENTS

1) CONDENSING UNIT

(F49/F72/R49/R72/GR70H) (F23/R23/GR26H) a) Unplug the power cord before service. b) Remove screw securing the lower grille.

* Remove screw securing the reinforce angle.(GR48S)

(GR48S)

(F49/F72/R49/R72/GR70H) (F23/R23/GR26H) a) Separate the compressor harness out of the terminal block. b) Remove screws securing the unit base plate and pull out condensing unit with care. c) Replace the necessary com-ponent.

(GR48S)

CAUTION

1. Please pull out or push in the unit base plate carefully to prevent capillary tube, pipes and wires from damaging.

2. It is recommend to arrange wires after you push in the unit base plate.

- 37 -

2-1) LAMP (GR26H) a) Unplug the power cord before service. b) Remove screw securing the Ad. Panel Frame and pull out the Ad. Panel Frame with care. c) Separate the Ad. Panel. d) Separate the Lamp from the Lamp Holder. e) Separate the Lamp Socket and replace the Lamp with care.

♠ Lamp Description: AC115V, F17T8/TL950

- 38 - a) Unplug the power cord before

service. b) Separate the Lamp from the

Lamp Holder. c) Separate the Lamp Socket and

the Lamp wire. d) Replace the Lamp with care.

2-2) LAMP (GR48S) a) Unplug the power cord before service. b) Remove screw securing the Ad. Panel Side. c) Separate the Ad. Panel. d) Separate the Lamp from the Lamp Holder. e) Separate the Lamp Socket and replace the Lamp with care.

♠ Lamp Description: AC115V, FHF32SSEX-D-5

- 39 - a) Unplug the power cord before service. b) Separate the Lamp from the

Lamp Holder. c) Separate the Lamp Socket and

the Lamp wire. d) Replace the Lamp with care

.

B. OPERATION AND ELECTRONIC CONTROLLER

FUNCTION

1. OPERATION FOR F23, F49, F72, R23, R49, R72 MODELS - - - - - B2

1) BASIC OPERATION

2) ELECTRONIC CONTROLLER SETTING MODE

3) NORMAL CONTROL PROCESS

4) ERROR CODE

2. OPERATION FOR GR26H, GR48S, GR70H MODELS - - - - - - - - - B12

1) BASIC OPERATION

2) DEFROST

3) CONTROL TEMPERATURE

4) LAMP

3. INSTRUCTION FOR RE-HINGING DOOR - - - - - - - - - - - - - - - - - B13

- 40 -

1. OPERATION FOR F23/F49/F72(FREEZER), R23/R49/R72(REFRIGERATOR)

1) BASIC OPERATION

① Plug in the power cord and turn on the power switch located on the bottom of the top grille right side.

[ The unit should be plugged into a 115V±10%, 60Hz (F23, F49, F72, R23, R49, R72 models) ]

② Display panel will be lit for 2 seconds with buzzer then displays cabinet interior temperature (T-sensor) and running conditions.

* Freezer : If cabinet interior temperature is higher than 14℉ (-10℃) compressor will run without

delay, and lower than 14℉ (-10℃), compressor will run after 3 minutes.

* Refrigerator : If cabinet interior temperature is higher than 50℉ (10℃) compressor will run

without delay, and lower than 50℉ (10℃), compressor will run after 3 minutes.

③ The default OPERATING TEMPERATURE SETTING

* Freezer :Temperature set point (setting mode sign [St]) is –5℉ (-20℃)

Temperature differential set point (setting mode sign [di]) is 8℉ (4℃)

Range of adjustable set point: -22℉~ 8℉(-30℃ ~ -10℃)

* Refrigerator : Temperature set point (setting mode sign [St]) is 36℉ (4℃) in solid door refrigerator

Temperature set point (setting mode sign [St]) is 35℉ (4℃) in glass door refrigerator

Temperature differential set point (setting mode sign [di]) is 8℉ (4℃)

Range of adjustable set point: 25℉~ 50℉ (2℃ ~10℃)

④ Defrost frequency

* Freezer : It is controlled by MICOM and the default defrost frequency is 12 hours.

* Refrigerator : It is controlled by MICOM and the default defrost frequency is 12 hours.

⑤ The light inside the cabinet comes on when the door is opened in Solid Door models

while light is always on in Glass Door models.

The cabinet interior cooling fan has 3 seconds delay when the door is closed.

When COMP. is OFF, EVA. fan repeats ON and OFF according to setting times

If door is opened , EVA. fan OFF and then closed the door, EVA. fan repeats ON and OFF according to setting times

- 41 -

⑥ If door is opened, door open warning sign (LED) will turn on.

If door is opened more than 30 seconds, the sound alarm beeps 3 times, if open more than 60 seconds, the sound alarm beeps 5 times and if open more than 5 minutes, the sound alarm will beep continuously.

⑦ Cabinet interior temperature

* Freezer : If it is higher than 14℉ (-5℃), the panel displays [Hi] and

lower than -50℉ (-40℃), the panel displays [Lo].

* Refrigerator : If it is higher than 68℉ (15℃), the panel displays [Hi] and

lower than 14℉ (-2℃), the panel displays [Lo].

- 42 -

2) ELECTRONIC CONTROLLER SETTING MODE

Display

St di th

Description

Temperature Setting Mode

Temperature Differential Setting Mode

Cabinet Temperature Verification Mode dt tb

Defrost Frequency Setting Mode

Rapid Freeze Mode (Freezer Only) dF Forced Defrost Mode

SE Temperature Unit Converter mode(℉ ↔℃)

※ In converting Temperature Unit (℉ ↔℃), 1℉ (1℃) deviation can occur.

- 43 -

No Setting Mode

1

Temperature

Setting

Mode

Mode

Sign

How to Setting

“St”

1.To enter this mode, press [MODE/SET] and [UP or DOWN] simultaneously until [St] is displayed.

2. Then press [MODE/SET] to see current temperature set point.

3. To change the set point, press [UP or DOWN] until the desired value is displayed.

4. At the end of the sequence, press [MODE/SET] to set the value.

5. To display the cabinet temperature again, press [UP or DOWN] until [th] is displayed and then press [VERIFY].

2

Temperature

Differential

Setting

Mode

“di”

6. Range of adjustable set point : -22℉~8℉(-30℃~ -10℃) (Freezer)

Range of adjustable set point : 25℉~50℉(2℃ ~ 10℃) (Refrigerator)

1. To enter this mode, press [MODE/SET] and [UP or DOWN] simultaneously until [di] is displayed.

2. Then press [MODE/SET] to see current temperature differential.

3. To change the set point, press [UP or DOWN] until the desired value is displayed.

4. At the end of the sequence, press [MODE/SET] to set the value.

5. To display the cabinet temperature again, press [UP or DOWN] until [th] is displayed and then press [VERIFY].

6. Range of adjustable set point : 4℉~16(2℃~10) (Freezer)

Range of adjustable set point : 4℉~16(2℃~10) (Refrigerator)

(The Unit of Setting : 2℉(2℃))

- 44 -

No

3

Setting Mode

Defrost

Frequency

Setting

Mode

Mode

Sign

How to Setting

“dt”

1. To enter this mode, press [MODE/SET] and [UP or DOWN] simultaneously until [dt] is displayed.

2. Then press [MODE/SET] to see current defrost frequency.

3. To change the defrost frequency, press [UP or DOWN] until the desired value is displayed.

4. At the end of the sequence, press [MODE/SET] to set the value.

5. To display the cabinet temperature again, press [UP or DOWN] until [th] is displayed and then press [VERIFY].

4

Forced Defrost

Mode

“dF”

6. Range of adjustable defrost frequency : 4Hr to 12Hr

(The Unit of frequency : 2Hr)

1. To enter this mode, press [MODE/SET] and [UP or DOWN] simultaneously until [dF] is displayed.

2. Then press [MANUAL DF] more than 2 seconds to start forced defrost.

5

6

Cancelation of

Forced Defrost

Mode

3. During defrosting, [dF] is displayed instead of the cabinet temperature.

Flash

"dF"

1. During forced defrost, press [MANUAL DF] more than

2 seconds to stop forced defrost.

2. The [dF] will be flash 5 times and then return to normal display mode.

1. To enter this mode, press [MODE/SET] and [UP or DOWN] simultaneously until [tb] is displayed.

2. Then press [MODE/SET] more than 2 seconds to start rapid freeze mode.

Rapid Freeze

Mode

(Freezer)

"tb"

3. During rapid freeze, [tb] is displayed instead of the cabinet temperature.

- 45 -

3) NORMAL CONTROL PROCESS

No FUNCTION

1

2

Initial

Operating

Normal

Operating

FUNCTION SPEC

1. After Power ON, Display panel will be lightened for 2 seconds with buzzer then displays cabinet interior temperature.

2. If cabinet interior temperature is higher than 14℉(-10℃) Freezer or 50℉(10℃)

Refrigerator, compressor will run without delay, and lower than 14℉(-10℃)

Freezer or 50℉(10℃) Refrigerator, compressor will run after 3 minutes.

1. Compressor and condenser fan motor is controlled by T-sensor and MICOM program.

2. Compressor ON/OFF Temperature

Compressor ON : Temperature Setting Value +

(Temperature Differential Setting Value/2)

Compressor OFF : Temperature Setting Value -

(Temperature Differential Setting Value/2) ex) St: -9℉(-23℃), di: 10℉(6℃) ⇒ Compressor ON : -9+(10/2) = -4℉(-20℃),

Compressor OFF: -9-(10/2) = -14℉(-26℃)

St: 39℉(4℃), di: 10℉(6℃) ⇒ Compressor ON : 39+(10/2) = 44℉(7℃),

Compressor OFF: 39-(10/2) = 34℉(1℃)

- 46 -

No

3

FUNCTION

Rapid

Freeze

(Freezer)

FUNCTION SPEC

1. Compressor and cabinet interior cooling fan is running continuously for

120 minutes without control by sensor.

2. It is impossible to set the other modes during Rapid Freeze Mode.

It is necessary to cancel the Rapid Freeze Mode before setting the other modes.

3. If Defrost Mode become in the Rapid Freeze Mode duration,

Defrost Mode will start after the Rapid Freeze Mode finished.

4. Rapid Freeze Mode will be start after Defrost Mode finished not during

Defrost Mode. [tb] is displayed from starting the Rapid Freeze Mode.

4

Defrost

(Freezer)

1. Defrost process is like below

Process Controlled Part

Pre-Cool

Compress or On

Evaporator Fan On

Condenser Fan On

Defrost Heater Off

Defrost

Pause

Compress or Off

Evaporator Fan Off

Condenser Fan Off

Defrost Heater On

Compress or Off

Evaporator Fan Off

Condenser Fan Off

Defrost Heater Off

Evaporator

Fan Delay

Compress or On

Evaporator Fan Off

Condenser Fan On

Defrost Heater Off

Description

① It prevent exceed temperature rise during defrosting,

② Cycle is run continuously until current compressor cut-out temperature reach.

③ Maximum time: 30minutes

① Preprogrammed frequency interval

② If D-sensor is higher than 50℉, defrost heater off

③ Maximum time: 40minutes

① Time: 5minutes

① If D-sensor is lower than -4℉, fan delay terminated

② Maximum time: 10minutes

Defrost

(Refrigerator)

1. Defrost cycle can be set up by button on control panel from 4h to 12hr.

(measurement unit: 2hr / default: 12hr)

2. Defrost control change

1) Defrost start : according to the defrost cycle by set up.

2) Defrost end : Comp OFF (during MAX time), Eva fan ON, dF ON (on display screen)

3) Defrost ends regardless of time when the temp is higher than pre-set defrost end temp.

4) 'dF' is displayed on screen for 3min after defrost end.

- Defrost end time (MAX) : 30min

- Defrost end temp : 41℉(5℃)

- 47 -

No

5

FUNCTION

Default

Setting

(Freezer)

FUNCTION SPEC

1. Temperature Setting : -5(-20), Temp.Differential Setting : 8(4) in display

2. Displayed Temperature : -8(-21)(comp. off) ~ 0(-17)(comp. on)

owing to correction factor

3. T-Sensor Operating Temperature :

-9(-22)(comp. off) ~ -1(-18)(comp. on)

4. Defrost Frequency Setting : 12Hr

Default

Setting

(Refrigerator)

1. Temperature Setting : 36(4), Temperature Differential Setting : 8(4)

2. Operating Temperature : 40(6)(comp. on) ~ 32(2)(comp. off)

3. Defrost Frequency Setting : 12Hr

6

7

Back UP

Error

Display

2. The setting is memorized.

1. If cabinet interior temp. is higher than 14℉(-5℃) Freezer or 68℉ (15℃)

Refrigerator, the panel displays [Hi], and lower than -50℉(-40℃) Freezer or

14℉(-2℃) Refrigerator, the panel displays [Lo].

2. Press [down] button 5 times with pressing and holding [up] button, the Error display mode is activated and it displays errors.

3. When there are more than 2 errors, the errors are displayed alternately.

4. If you press [MODE/SET] button, the error display mode will be finished

- 48 -

4) ERROR CODE

4-1) Freezer

Error

Code

Condition Possible Cause When error occurring, operation

C1

During normal mode (not defrost mode), D-sensor sensing is • Ambient Temperature higher than 23℉ and too low (below-5℉)

Compressor does not run for • T-sensor defective

60min after compressor off

1) Register “C1”

2) Compressor ON:20Minutes

3) Compressor OFF:5Minutes

4) Operate 2),3) three times

5) Operate Normal Mode

C2

Entering defrost mode, D-sensor sensing is higher than 50℉ and

T-sensor sensing is lower than

• D-sensor defective

14℉

1) Register “C2”

2) Operate Pre-Cool step:

30Minutes

3) Defrost Heater ON: 20Minutes

4) Operate the rest Defrost Mode

C3

After defrost mode elapsed for

40minutes, D-sensor sensing is

• D-sensor defective

• Defrost heater lower than 23℉ defective

1) Register “C3”

2) Operate the rest Defrost Mode

C4

T-sensor sensing is more

• Refrigerant leak

• Control board than 18℉higher than temperature set point for 4hours

Additional Possible Cause: Too many hot goods loaded!!

defective

• Door not sealing

• Not enough defrosts

• Condenser dirty

• Sensor defective

1) Register “C4”

2) Compressor ON:20Minutes

3) Compressor OFF:5Minutes

4) Operate 2),3) three times

5) Operate Normal Mode

• N/A N/A C- No error code

- 49 -

4-2) Refrigerator

Error

Code

Condition Possible Cause When error occurring

C1

C2

C3

C4

During normal mods, Tsensor sensing lasts “Lo" status more than 60 minutes

• T-Sensor defective

• Lead defective

1) Register "C1"

2) Compressor ON : 15 Minutes

3) Compressor OFF: 5 Minutes

4) Operate 2), 3) repeatedly until the error is clear

5) Operate Normal Mode

6) Defrost cycle is operated by Dsensor

1) Register “C2”

2) Compressor OFF: 22 Minutes

During normal mode Tsensor sensing lasts "Hi"

• Sensor housing defective (due status more than 60 to other substance)

• Sensor internal defective minutes

3) Compressor ON : 15 Minutes

4) Operate 2), 3) repeatedly until the error is clear

5) Operate Normal Mode

6) Defrost cycle is operated by Dsensor

After defrost mode elapsed for 30 minutes.

D-sensor sensing is

• Not enough defrosts lower than 32°F

1) Register "C3

2) Error check

3) Main power reset

T-Sensor sensing is more than 18°F higher than point for 4 hours and more temperature set

• Too many hot goods loaded

• Refrigerant leak

• Control board defective

• Door not sealing

• Not enough defrosts

• Condenser dirty

• Sensor defective

1) Register “C4”

2) Compressor OFF: 15 Minutes

3) Compressor ON : 5 Minutes

4) Operate 2), 3) repeatedly until the error is clear

5) Operate Normal Mode

6) Defrost cycle is operated by Dsensor

C5

D-Sensor Sensing is over 140°F or under -

• D-Sensor defective

• Lead defective

55.4°F for 1 minute

1) Register "C5”

2) Defrost end is operated by time

(30 Minutes)

- 50 -

2. OPERATION FOR GR26H, GR48S, GR70H MODELS

1) BASIC OPERATION

① Plug in the power cord and turn on the lamp switch located on the left of the temperature controller.

[ The unit should be plugged into a 115V±10%, 60Hz]

② The controller(Thermostat) has been preset "3" position at the factory

2) DEFROST

① This unit uses an off cycle defrost. No needs any programming.

3) CONTROL TEMPERATURE

① The temperature controller is mounted on top of the cabinet interior.

② The controller has been preset "4" position at the factory to maintain the average cabinet temperature of 38℉ (3℃)

ON

OFF

LAMP S/W Only

4) LAMP

① The light comes on when the lamp switch is on.

- 51 -

5 5

TEMP. CONTROLLER

3. INSTRUCTION FOR RE-HINGING DOOR (F23/R23)

Re hinging

- 52 -

▣ To change the door mounting from right hand to left hand hinges you will need the following;

▣ Medium to large size Phillips Screwdriver

146413 Door Hinge Kit - Lower Left

146442 Door Hinge Kit - Top Left

STEP1. Remove the door (Figure 1) a) Remove the Top Grille (seven screws) b) Remove the Lower Grille (four screws) c) Remove the Top Hinge (#1) (four screws) d) Lift and remove the Door e) Remove the Bottom Hinge (#7) (four screws)

STEP2. Convert the Door a) Replace the Spring Guide (#4) with Bushing (#9)-(SEE 146413 HINGE KIT) b) Replace the Bushing (#5) with the Spring Guide (#4).

STEP3. Reinstall the Door (figure 2) a) Install Bottom Left Hinge (#1) with Bushing (#10)-(SEE 146413 HINGE KIT) b) Set Door in place on Bottom Hinge c) Insert Spring (#8) (silver) into Spring Guide (#4) as shown in figure 3-(SEE 146442 HINGE KIT) d) Install the Top Hinge (#7) as shown in figure 4-(SEE 146442 HINGE KIT)

(confirm that spring ends are engaged in the spring guide and hinge) e) Replace the Top and Lower Grilles

Note:

The silver colored spring (#8) is for left hand hinged door and the yellow color spring (#3) is for right hand hinged doors.

The letter "L" is marked on the left hand bushings (#9 and #10)

- 53 -

C. SERVICE LIST AND EXPLODED VIEW

1. COMMERCIAL FREEZERS AND REFRIGERATORS - - - - - - - - - - C2

1) F23/F49/F72-S, R23/R49/R72-S SERVICE LIST & EXPLODED VIEW

2) F23/F49/F72-SH, R23/R49/R72-SH SERVICE LIST & EXPLODED VIEW

3) R23/R49/R72-G SERVICE LIST & EXPLODED VIEW

2. MERCHANDISERS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C23

1) GR26H, GR48S, GR70H SERVICE LIST & EXPLODED VIEW

- 54 -

15

16

17

18

19

12

13

14

20

21

1. COMMERCIAL FREEZERS AND REFRIGERATORS

1-1. SERVICE LIST (F23/F49/F72-S , R23/R49/R72-S)

PART No.

No. PART NAME

Door Hinge Kit - Top Right

F23-S F49-S F72-S R23-S R49-S R72-S

146441 146441 146441 146441 146441 146441 1

2 Door Hinge Kit - Top Left NA 146442 146442 NA 146442 146442

3

4

5

6

Door Hinge Kit - Lower Right

Door Hinge Kit - Lower Left

Door Hinge Kit - Lower Center

Control PCB Assembly (115V)

Used thru 12/2014

Control PCB Assembly (115V)

Universal (℉/℃) PCB

Main Transformer (115V)

146412 146412 146412 146412 146412 146412

NA 146413 146413 NA 146413 146413

NA NA 146414 NA NA 146414

146416 146417 146418 150313 150313 150313

150539 150540 150541 150538 150538 150538

146420 146420 146420 146420 146420 146420 7

8

9

10

11

11-1

DC Relay

Relay Wire Harness

Front PCB Wire Harness

Temperature Sensor use up to 12/2011

Sensor Kit (Includes

T-sensor and D-sensor)

Pilaster

146421 146421 146421 146421 146421 146421

146423 146423 146423 146423 146423 146423

146424 146424 146424 146424 146424 146424

146425 146427 146429

146426 146428 146430 146426 146428 146430

146411 146411 146411 146411 146411 146411

22

23

Shelf Clip 146489 146489 146489 146489 146489 146489

Door Assembly - Right Hand 146436 146437 146439 146436 146437 146439

Door Assembly - Left Hand

Door Gasket

Lamp (115V)

Lamp Socket

Lamp Cover

Top Grille Assembly (115V)

Top Grill Cover - Right

Front PCB Assembly

Used thru 12/2014

Front PCB Assembly

Universal (℉/℃) PCB

Control Decal

NA 146438 146440 NA 146438 146440

146444 146444 146445 146444 146444 146445

146408 146408 146408 146408 146408 146408

146409 146409 146409 146409 146409 146409

146410 146410 146410 146410 146410 146410

146433 146434 146435 146433 146434 146435

146431 146431 146431 146431 146431 146431

146419 146419 146419 146419 146419 146419

150537 150537 150537 150537 150537 150537

146432 146432 146432 146432 146432 146432

- 55 -

No.

33

34

35

30

31

32

27

28

29

24

25

26

41

42

43

36

37

38

39

40

PART NAME

Light Switch

Door Lock& Key

Power Switch

Condensate Pan w/paper

Lower Grille Assembly

Caster Kit

Power Cord

Evaporator Coil

Defrost Limit Switch

Defrost Heater (115V)

Drain Heater (115V)

Drain Pan Heater (115V)

Evaporator Fan Guard

F23-S F49-S

PART No.

F72-S R23-S R49-S R72-S

146449 146449 146449 146449 146449 146449

146443 146443 146443 146443 146443 146443

146450 146450 146450 146450 146450 146450

146386 146387 146387 146386 146387 146387

146388 146389 146390 146388 146389 146390

100436 100436 100437 100436 100436 100437

138533 138533 161576 138533 138533 138533

146392 146394 146396 146391 146393 161569

146404 146404 146404 NA NA NA

146397 146398 146399

146403 146403 146403

146400 146401 146402

NA

NA

NA

NA

NA

NA

NA

NA

NA

146405 146405 146405 146405 146405 146405

Evaporator Fan Blade 146406 146406 146406 146406 146406 146406

Evaporator Fan Motor (115V) 146407 146407 146407 146407 146407 146407

Condenser Coil

Condenser Fan Blade

Condenser Fan Motor (115V) 146370 146370 146370 146370 146370 146370

Suction pipe(B) Assembly

Dryer

161567 161570 161570 161562 161562 161567

146371 146371 146371 146371 146371 146371

161568 161571 161574 161563 161563 161568

161564 161564 161575 161564 161564 161564

44

45

Compressor (115V) 150556 161572 161577 161565 161565 150556

46

47

Compressor Electrical Kit

Shelf

Shelf Kit(1Shelf + 4 Clips)

150557 161573 161578 161566 161566 150557

146446 146446

146446 146447 146446 146447

146448 146448

146516 146517

146516

146518

146516 146517

146516

146518

* Shelf: F(R) 72 - 146446 (ENDS), 146448 (CENTER)

* Shelf Kit: F(R) 72 - 146516 (ENDS), 146518 (CENTER)

* Cap. Tube: 161592(F23/49, R23/49/72), 161593(F72)

- 56 -

1-2. F23-S EXPLODED VIEW

- 57 -

1-3. F49-S EXPLODED VIEW

- 58 -

1-4. F72-S EXPLODED VIEW

- 59 -

1-5. R23-S EXPLODED VIEW

- 60 -

1-6. R49-S EXPLODED VIEW

- 61 -

1-7. R72-S EXPLODED VIEW

- 62 -

16

17

18

19

20

21

1

2

3

4

5

2-1. SERVICE LIST( F23/F49/F72-SH , R23/R49/R72-SH)

No. PART NAME

Door Hinge Kit - Top Right

PART No.

F23-SH F49-SH F72-SH R23-SH R49-SH R72-SH

146441 146441 146441 146441 146441 146441

6

Door Hinge Kit - Top Left

Door Hinge Kit - Lower Right

Door Hinge Kit - Lower Left

Door Hinge Kit - Lower Center

Control PCB Assembly (115V)

Used thru 12/2014

Control PCB Assembly (115V)

Universal (℉/℃) PCB

Main Transformer (115V)

NA

146412 146412 146412 146412 146412 146412

NA 146413 146413 NA 146413 146413

NA

146442 146442

NA 146414

NA

NA

146442 146442

NA 146414

146416 146417 146418 150313 150313 150313

150539 150540 150541 150538 150538 150538

146420 146420 146420 146420 146420 146420 7

8

9

10

11

11-1

12

13

DC Relay

Relay Wire Harness

Front PCB Wire Harness

Temperature Sensor use up to 12/2011

Sensor Kit (Includes

T-sensor and D-sensor)

Pilaster

146421 146421 146421 146421 146421 146421

146423 146423 146423 146423 146423 146423

146424 146424 146424 146424 146424 146424

NA NA NA 146425 146427 146429

146426 146428 146430 146426 146428 146430

146411 146411 146411 146411 146411 146411

146489 146489 146489 146489 146489 146489

14

14-1

15

15-1

Shelf Clip

Door Assembly - Upper Right

Hand

Door Assembly - Upper Left

Hand

Door Assembly – Lower Right

Hand

Door Assembly – Lower Left

Hand

Door Gasket

160501 160505 160510 160501 160505 160510

NA 160507 160512 NA 160507 160512

160502 160502 160511 160502 160502 160511

NA 160508 160513 NA 160508 160513

160503 160503 160514 160503 160503 160514

22

23

Lamp (115V)

Lamp Socket

Lamp Cover

Top Grille Assembly (115V)

Top Grill Cover - Right

Front PCB Assembly

Usedthru 12/2014

Front PCB Assembly

Universal (℉/℃) PCB

Control Decal

146408 146408 146408 146408 146408 146408

146409 146409 146409 146409 146409 146409

146410 146410 146410 146410 146410 146410

146433 146434 146435 146433 146434 146435

146431 146431 146431 146431 146431 146431

146419 146419 146419 146419 146419 146419

150537 150537 150537 150537 150537 150537

146432 146432 146432 146432 146432 146432

- 63 -

No.

33

34

35

30

31

32

27

28

29

24

25

26

41

42

43

36

37

38

39

40

44

45

PART NAME

Light Switch

Door Lock& Key

Power Switch

Condensate Pan w/paper

Lower Grille Assembly

Caster Kit

Power Cord

Evaporator Coil

Defrost Limit Switch

Defrost Heater (115V)

Drain Heater (115V)

Drain Pan Heater (115V)

Evaporator Fan Guard

Compressor (115V)

F23-SH F49-SH

PART No.

F72-SH R23-SH R49-SH R72-SH

146449 146449 146449 146449 146449 146449

146443 146443 146443 146443 146443 146443

146450 146450 146450 146450 146450 146450

146386 146387 146387 146386 146387 146387

146388 146389 146390 146388 146389 146390

100436 100436 100437 100436 100436 100437

138533 138533 161576 138533 138533 138533

146392 146394 146396 146391 146393 161569

146404 146404 146404 NA NA NA

146397 146398 146399

146403 146403 146403

146400 146401 146402

NA

NA

NA

NA

NA

NA

NA

NA

NA

146405 146405 146405 146405 146405 146405

Evaporator Fan Blade 146406 146406 146406 146406 146406 146406

Evaporator Fan Motor (115V) 146407 146407 146407 146407 146407 146407

Condenser Coil

Condenser Fan Blade

Condenser Fan Motor (115V) 146370 146370 146370 146370 146370 146370

Suction pipe(B) Assembly

Dryer

161567 161570 161570 161562 161562 161567

146371 146371 146371 146371 146371 146371

161568 161571 161574 161563 161563 161568

161564 161564 161575 161564 161564 161564

150556 161572 161577 161565 161565 150556

Compressor Electrical Kit 150557 161573 161578 161566 161566 150557

46

47

Shelf

Shelf Kit(1Shelf + 4 Clips)

146446 146447

146516 146517

146446

146448

146516

146518

146446 146447

146516 146517

146446

146448

146516

146518

48

49

Door Hinge Kit - Center Right 160504 160504 160504 160504 160504 160504

Door Hinge Kit - Center Left NA 160509

* Shelf: F(R) 72 - 146446 (ENDS), 146448 (CENTER)

* Shelf Kit: F(R) 72 - 146516 (ENDS), 146518 (CENTER)

160509

* Cap. Tube: 161592(F23/49-SH, R23/49/72-SH), 161593(F72-SH)

NA 160509 160509

- 64 -

2-2. F23-SH EXPLODED VIEW

- 65 -

2-3. F49-SH EXPLODED VIEW

- 66 -

2-4. F72-SH EXPLODED VIEW

- 67 -

2-5. R23-SH EXPLODED VIEW

- 68 -

2-6. R49-SH EXPLODED VIEW

- 69 -

2-7. R72-SH EXPLODED VIEW

- 70 -

3-1. SERVICE LIST (R23/R49/R72-G)

No. PART NAME

1

2

3

4

5

6

11-1

16

17

18

19

12

13

14

15

20

21

7

8

8A

9

10

10A

11

22

23

Door Hinge Kit - Top Right

Door Hinge Kit - Top Left

Door Hinge Kit - Lower Right

Door Hinge Kit - Lower Left

Door Hinge Kit - Lower Center

Control PCB Assembly (115V)

Used thru 12/2014

Control PCB Assembly (115V)

Universal (℉/℃) PCB

Main Transformer (115V)

DC Relay

LED DRIVER

Relay Wire Harness

Front PCB Wire Harness

LED Wire Harness

Temperature Sensor use up to 12/2011

Sensor Kit (Includes

T-sensor and D-sensor)

Pilaster

Shelf Clip

Door Assembly - Right Hand

Door Assembly - Left Hand

Door Gasket

LED (6W)

LED Fixture

LED wire cover

Top Grille Assembly

Top Grill Cover - Right

Front PCB Assembly

Used thru 12/2014

Front PCB Assembly

Universal (℉/℃) PCB

Control Decal

150538

146420

146421

160530

146423

146424

160529

146425

146426

146411

146489

160520

NA

160525

160526

160527

160528

160531

146431

146419

R23-G

160515

NA

160517

NA

NA

150313

150537

146432

- 71 -

150538

146420

146421

160530

146423

146424

160533

146427

146428

146411

146489

160521

160523

160525

160526

160527

160528

160534

146431

146419

PART No.

R49-G

160515

160516

160517

160518

NA

150313

150537

146432

150538

146420

146421

150571

146423

146424

160535

146429

146430

146411

146489

160522

160524

146482

160526

160527

160528

160536

146431

146419

R72-G

160515

160516

160517

160518

160519

150313

150537

146432

No. PART NAME

R23-G

40

41

42

43

44

37

38

39

45

46

47

32

33

34

35

36

29

30

31

24

24A

25

26

27

28

Light S/W  Door Switch (rename)

Light Switch

Door Lock& Key

Power Switch

Condensate Pan w/paper

Lower Grille Assembly

Caster Kit

Power Cord

Evaporator Coil

Defrost Limit Switch

Defrost Heater (115V)

Drain Heater (115V)

Drain Pan Heater (115V)

Evaporator Fan Guard

Evaporator Fan Blade

Evaporator Fan Motor (115V)

Condenser Coil

Condenser Fan Blade

Condenser Fan Motor (115V)

Suction pipe(B) Assembly

Dryer

Compressor (115V)

Compressor Electrical Kit

Shelf

146449

160532

146443

146450

146386

146388

100436

138533

146391

NA

NA

NA

NA

146405

146406

146407

161562

146371

146370

161563

161564

161565

161566

146446

Shelf Kit(1Shelf + 4 Clips) 146516

* Shelf: F(R) 72 - 146446 (ENDS), 146448 (CENTER)

* Shelf Kit: F(R) 72 - 146516 (ENDS), 146518 (CENTER)

* Cap. Tube: 161592(R23/49/72-G)

- 72 -

PART No.

R49-G

146393

NA

NA

NA

NA

146405

146406

146407

146449

160532

146443

146450

146387

146389

100436

138533

161562

146371

146370

161563

161564

161565

161566

146447

146517

R72-G

161569

NA

NA

NA

NA

146405

146406

146407

146449

160532

146443

146450

146387

146390

100437

138533

161567

146371

146370

161568

161564

150556

150557

146446 / 146448

146516 / 146518

3-2. R23-G EXPLODED VIEW

- 73 -

3-3. R49-G EXPLODED VIEW

- 74 -

3-4. R72-G EXPLODED VIEW

- 75 -

2. MERCHANDISERS

1-1. SERVICE LIST (GR26H, GR48S, GR70H)

13-2

20

21

22

23

24

25

17

18

19

14

15

16

5

6

3

4

7

1

2

8

9

10

11

12-1

12-2

13-1

No. PART NAME

Door Hinge Kit - Top Right

Door Hinge Kit - Top Left

Door Hinge Kit - Lower Right

Door Hinge Kit - Lower Left

Door Hinge Kit - Lower Center

Ballast

Pilaster

Shelf Clip

Door Assembly - Right Hand

Door Assembly - Left Hand

Door Gasket

Advertising Panel Wire A

Advertising Panel Wire B

Interior Light Wire A

Interior Light Wire B

Lamp (115V)

Lamp Cover End

Lamp Cover

Advertising Panel - Blank

Advertising Panel Frame

Advertising Panel Frame-Left

Advertising Panel Frame-Right

Advertising Panel Frame-Bottom

Advertising Panel Frame-Top

Condensate Pan w/paper

Lower Grille Assembly

Foot Kit

NA

NA

146466 / 146467

146468

146469

146495

146497

NA

NA

NA

NA

146386

146463

146502

GR26H

146481

NA

146471

NA

NA

146491

146470

146489

146478

NA

146483

150190

NA

- 76 -

150526

150527

146466

146468

146469

146494

NA

146505

146506

146503

146504

146460

146462

146502

PART No.

GR48S

NA

NA

NA

NA

NA

146491

146470

146489

146477

146480

NA

150524

150525

NA

NA

NA

NA

NA

146493

NA

146500

146501

146498

146499

146387

146461

146502

GR70H

160515

160516

160517

160518

160519

NA

146411

146489

161582

161584

146482

NA

NA

No. PART NAME

36

37

38

31

32

33

34

35

39

40

41

42

26

27

28

29

30

Power Cord

Evaporator Coil

Evaporator Fan Guard

Evaporator Fan Blade

Evaporator Fan Motor

Temperature Control

Light Switch

Capillary Tube

Suction pipe(B) Assembly

Dryer

Condenser Coil

Condenser Fan Blade

Condenser Fan Moto

Compressor

Compressor Electrical Kit

Shelf

Shelf Kit(1Shelf + 4Clips)

43

44

45

SMPS (60W)

LED (20W)

LED (6W)

NA

NA

NA

46 LED Fixture NA

47 LED wire cover

* Shelf: GR48S - 146486 (LEFT), 146487 (RIGHT)

NA

* Shelf Kit: GR48S - 146521 (LEFT), 146522 (RIGHT)

GR70H - 161586 (ENDS), 161588 (CENTER)

* Cap. Tube: 161592(GR70H)

- 77 -

GR26H

146475

146465

146405

146406

146407

146474

146450

146458

146457

146384

146372

146371

146370

146452

146454

146488

146523

146473

146450

NA

146456

146384

146455

146371

146370

PART No.

GR48S

146475

146464

146405

146406

146407

146451

146453

146486 / 146487

146521 / 146522

NA

NA

NA

NA

NA

GR70H

138533

161569

146405

146406

146407

146472

146450

NA

161568

161564

161567

146371

146370

150556

150557

NA / NA

161586 / 161588

161580

161581

160526

160527

160528

1-2. GR26H EXPLODED VIEW

- 78 -

1-3. GR48S EXPLODED VIEW

- 79 -

1-4. GR70H EXPLODED VIEW

- 80 -

D. COMPRESSOR & ACCESSORIES CHECK LIST

1. F23-S/SH, R72-G, R72-S/SH, GR70H - - - - - - - - - - - - - - - - - - - - D2

2. F49-S/SH - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D3

3. F72-S/SH - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D4

4. R23/R49-S/SH, R23/49-G - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D5

5. GR26H - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D6

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D7 6. GR48S

- 81 -

1. F23-S/SH, , R72-S/SH/G, GR70H

① Compressor Spec. : NEK2150GK (R-404A), 115V/60Hz, CSR Type

② Maker : EMBRACO

③ Cooling Capacity : 628kcal/Hr - LBP

④ Starting Capacitor Spec. : 189~227 ㎌ / 165V

⑤ Running Capacitor Spec. : 25 ㎌ / 400V

⑥ Relay Spec. : RVA9AD3C-121

⑦ O.L.P Spec. : T0873/G9

OLP

EARTH

3

C

S

M

* Comp. Winding Resistance: C - M → 0.77Ω, C - S → 4.5Ω (RT 25 ℃( 77℉))

* O.L.P Winding Resistance: 3- C → 0 Ω (OK), ∞ Ω (NG)

* Relay Winding Resistance: 1 -2 → 0 Ω (OK), ∞ Ω (NG)

BLACK

WIRE

WIRE

WHITE

2

1

< COMP. Wiring Diagram>

- 82 -

2. F49-S/SH

① Compressor Spec. : NT2178GKV (R-404A), 115V/60Hz, CSR Type

② Maker : EMBRACO

③ Cooling Capacity : 903kcal/Hr - LBP

④ Starting Capacitor Spec. : 243~292 ㎌ / 165V

⑤ Running Capacitor Spec. : 35 ㎌ / 400V

⑥ Relay Spec. : RVA9AD3C-121

⑦ O.L.P Spec. : MST18RN-3041

S

C

3

M

EART

OL

* Comp. Winding Resistance: C - M → 0.40Ω, C - S → 2.60Ω (RT 25 ℃( 77℉))

* O.L.P Winding Resistance: 3 - C → 0 Ω (OK), ∞ Ω (NG)

* Relay Winding Resistance: 1 - 2 → 0 Ω (OK), ∞ Ω (NG)

BLACK

WIRE

WIRE

WHITE

2

1

- 83 -

< COMP. Wiring Diagram>

3. F72-S/SH

① Compressor Spec. : NT2192GKV (R-404A), 115V/60Hz, CSR Type

② Maker : EMBRACO

③ Cooling Capacity : 1,051kcal/Hr - LBP

④ Starting Capacitor Spec. : 243~292 ㎌ / 165V

⑤ Running Capacitor Spec. : 35 ㎌ / 400V

⑥ Relay Spec. : RVA2AE3C-105

⑦ O.L.P Spec. : CRA1773-3029 GA3RMU0002

S

C

M

OL

3

EART

* Comp. Winding Resistance: C - M → 0.34Ω, C - S → 2.59Ω (RT 25 ℃( 77℉))

* O.L.P Winding Resistance: 3 -

C → 0 Ω (OK), ∞ Ω (NG)

* Relay Winding Resistance: 1 - 2 → 0 Ω (OK), ∞ Ω (NG)

BLACK

WIRE

WIRE

WHITE

2

1

- 84 -

< COMP. Wiring Diagram>

4. R23/R49-S/SH, R23/R49-G

① Compressor Spec. : NW108LHB1 (R-134a), 115V/60Hz, CSR Type

② Maker : DAEWOO-KOREA

③ Cooling Capacity : 325kcal/Hr - LBP

④ Starting Capacitor Spec. : 125 ㎌ / 200V

⑤ Running Capacitor Spec. : 16 ㎌ / 250V

⑥ Relay Spec. : R6R8MD22SS

⑦ O.L.P Spec. : 4TM801SFBZZ-52

C(C-1)

C-1

3 2

S(6) M(5)

< COMP. Terminal >

< OLP >

1

5

< RELAY >

C-1 OLP

3

2

RELAY

1

< COMP. Wiring Diagram>

* Comp. Winding Resistance: C - M → 1.20Ω, C - S → 6.18Ω(RT 25℃,77℉)

* O.L.P Winding Resistance: 1 - 11 → 0 Ω (OK), ∞ Ω (NG)

On/Off Temperature - O/T: 135 ℃, C/T: 61℃

* Relay Winding Resistance: M (5) – C-1 → 0 Ω (OK), ∞ Ω (NG)

S (6) – C-1 → ∞ Ω (OK)

* PTC: 6.8

- 85 -

6

6. GR26H

① Compressor Spec. : SK182C-L2U (R-134a), 115V/60Hz, RSCR Type

② Maker : SAMSUNG-KOREA

③ Cooling Capacity : 243kcal/Hr - LBP

④ Relay Spec. : PTHAR-T4R7M180D/J531Q32E4R7M1802

⑤ O.L.P Spec. : 4TM444NHBYY-53

C(1)

2 3

1

S(6)

M(5)

5

6

1-1

< Comp. Terminal > < RELAY

>

< OLP >

* Comp. Winding Resistance: C - M → 2.3Ω, C - S → 3.8Ω (RT 25 ℃(77 ℉))

* O.L.P Winding Resistance: 1 - 11 → 0 Ω (OK), ∞ Ω (NG)

* Relay Winding Resistance: 5 - 6 → 0 Ω (OK), ∞ Ω (NG)

2 - 3 → 0 Ω (OK), ∞ Ω (NG)

* Measuring the resistance, the bottom of the relay must be downward (like fig.1)

Fig.1

3

1

OLP

2

RELAY

< COMP. Wiring Diagram>

- 86 -

7. GR48S

① Compressor Spec. : CAJ4476Y (A) (R-134a), 115V/60Hz, CSIR Type

② Maker : TECUMSEH-FRANCE

③ Cooling Capacity : 1,946kcal/Hr - HBP

④ Starting Capacitor Spec. : 250 ㎌ / 160V

⑤ Relay Spec. : 3ARR3*2M*

⑥ O.L.P Spec. : CRA38014

C

OLP

S

M

3

S/C

Earth

< RELAY BOX >

* Comp. Winding Resistance: C - M → 0.72Ω, C - S → 3.68Ω (RT 20 ℃( 68℉))

* O.L.P Winding Resistance: 3 -

C → 0 Ω (OK), ∞ Ω (NG)

* Relay Winding Resistance: 1 - 2 → 0 Ω (OK), ∞ Ω (NG)

Black wire

RELAY

2

White wire

1

2

1

2N

3L

4

5

S/C

1

AC115V

60Hz

OLP

S

3

C

< COMP. Wiring Diagram>

M

- 87 -