Abstract

This document provides Virtual Connect release information for version 4.21. This document supercedes the information in the release notes published with version 4.20. This document is intended for the person who installs, administers, and troubleshoots servers and storage systems. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.

Part Number: 798988-001

October 2014

Edition: 1

© Copyright 2014 Hewlett-Packard Development Company, L.P.

The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.

Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212,

Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor’s standard commercial license.

Adobe™ is a trademark of Adobe Systems Incorporated.

Contents

Update recommendation ............................................................................................................... 4

Supersedes information ................................................................................................................. 4

Product models ............................................................................................................................. 4

Operating systems ........................................................................................................................ 5

Languages ................................................................................................................................... 5

Enhancements .............................................................................................................................. 5

Fixes ........................................................................................................................................... 6

Issues and workarounds ................................................................................................................ 7

Prerequisites ................................................................................................................................. 8

Installation instructions ................................................................................................................. 10

Important notes ........................................................................................................................... 13

Acronyms and abbreviations ........................................................................................................ 15

Related information ..................................................................................................................... 15

Documentation feedback ............................................................................................................................. 16

Contents 3

Update recommendation

Update Recommendation: Recommended

Supersedes information

Supersedes: 4.20

For Virtual Connect 4.21, these release notes comprise the release documentation set. Use the following documents for Virtual Connect 4.21:

HP Virtual Connect for c-Class BladeSystem Version 4.20 User Guide

HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 4.20 User

Guide

HP Virtual Connect for c-Class BladeSystem Setup and Installation Guide, Version 4.20

All of these documents can be found on the HP website ( http://www.hp.com/go/vc/manuals ).

Product models

IMPORTANT: This document may have references to products yet to be announced. For more information, contact your HP representative.

Virtual Connect 4.21 is supported on the following interconnect modules:

HP VC Flex-10/10D Module

HP VC FlexFabric 10Gb/24-port Module

HP VC Flex-10 10Gb Enet Module

HP VC FlexFabric-20/40 F8 Module

HP VC 4Gb Fibre Channel Module for BladeSystem c-Class (enhanced NPIV)

HP VC 8Gb 20-Port FC Module

HP VC 8Gb 24-Port FC Module

IMPORTANT: Beginning with VC 3.70, the HP 1/10Gb VC Enet Module (399593-B22) and the

HP 1/10Gb-F VC Enet Module (447047-B21) are no longer supported. Beginning with VC 4.10, the HP 4Gb VC-FC Module (409513-B21) is no longer supported.

Update recommendation 4

Operating systems

The HP Virtual Connect version 4.21 firmware package operates in an embedded environment within each

Virtual Connect module; therefore, it is not dependent on any operating system.

For more information, see the HP Operating Systems and Virtualization Software Support for ProLiant Servers web page on the HP website ( http://h18004.www1.hp.com/products/servers/software/index.html

), or view the Operating Systems section for Integrity Servers on the HP website

( http://h20341.www2.hp.com/integrity/us/en/systems/integrity-systems-overview.htm

).

Languages

Languages supported for this release: English, Japanese

Enhancements

The VC 4.21 release includes no new features.

Version 4.20 of Virtual Connect contains support for the following enhancements:

Manageability enhancements: o

The sFlow feature allows network administrators to monitor and analyze the network traffic flow in the datacenter. The sFlow settings can be modified by users with Network, Domain, or Server user role permissions. o

FIP snooping information display, which provides FCoE connectivity details for administrators. o

CLI show config command, with the includepoolinfo option to save a configuration script that includes MACs, WWNs, and virtual serial numbers for your domain. For more information, see the HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem User Guide on the HP website ( http://www.hp.com/go/vc/manuals ).

The following HP products are now supported: o o

HP Virtual Connect FlexFabric-20/40 F8 Module

HP FlexFabric 20Gb 2-port 630FLB Adapter o o

HP FlexFabric 20Gb 2-port 630M Adapter

HP LPe1605 16Gb FC HBA for BladeSystem c-Class

Operating systems 5

Fixes

The VC 4.21 release resolves the following issue:

After updating Flex-10/10D modules to VC firmware 4.20, one or more modules might shut down due to a single instance of a high temperature reading from one of eight sensors on the module. For additional information, see Customer Advisory c04459474

( http://h20564.www2.hp.com/portal/site/hpsc/public/kb/docDisplay/?docId=c04459474 ).

The VC 4.20 release resolves the following issues:

DCBX traffic will not be sent on any VC uplink ports that are not capable of FCoE traffic. For more information, see related Customer Advisory c04173675

( http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c

04173675 ).

VCEM is unable to add a domain containing profiles with user-defined Network Access Groups into a

VC Domain Group. See Customer Advisory c0380654

( http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c

03805654 ).

When manually removing an external-manager using the VCM CLI, if the Virtual Serial Number range is not properly specified, the server profile control will not be released from external management.

When updating VC firmware to 4.10, VCSU activation may abort on other modules after the backup module is activated. See Customer Advisory c04122651

( http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c

04122651 ).

VCM CLI hangs on the show config command when the SNMP read-only community string is null/blank.

After upgrading the Virtual Connect firmware to version 4.10 on a VC domain that contains VC Fibre

Channel 8Gb/20 port modules, some of the server blade HBAs may fail to log back into the SAN fabric. See Customer Advisory c04103189

( http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c

04103189 ).

Some Fibre Channel statistics may be invalid on Virtual Connect FlexFabric modules running firmware version 4.10. See Customer Advisory c04117141

( http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c

04117141 ).

Stacking link DAC cables fail after firmware upgrade.

CLI command reset statistics with encX:Y:* wildcard does not work.

Cannot "Reset Statistics" from GUI on FlexFabric FC connections.

Profiles may not display correctly in the VCM Web UI when they are created via VCM CLI and the

SharedServerVlanID is set to false.

VC-FC 8/24 modules may unexpectedly reboot due to a software fault when an HPUX HPVM is in use on blades in the same enclosure.

Fixes 6

Browsers can remember the cryptKeyrestore password.

In HP SIM, when a Managed Report is run against VC-FC modules, the returned description for the modules appear as NULL or as the serial number of the module.

The detailed port statistics field cosq[N]_ucast_DroppedPkts incorrectly reports the number of per CoS queue dropped packets on HP VC FlexFabric 10Gb/24-port Modules and HP VC Flex-10 10Gb Enet

Modules.

After an enclosure import or recovery, profiles that enter a pending state could encounter an FCoE SAN outage with FlexFabric 10Gb/24 Port Modules.

Issues and workarounds

Issue

Configbackup restore fails in configuration with Multiple Enclosure after upgrading from VC 2.xx to VC

4.20.

Workaround

HP recommends customers with an ME environment upgrade from VC 2.xx to an intermediate firmware version, such as VC 3.70 or VC 4.10, and then upgrade to VC 4.20.

Issue

VC shows a profile pending when a VC module is removed and inserted.

Workaround

The customer must power cycle the server in a maintenance window to clear the status.

Issue

A server using an HP FlexFabric 20Gb 2-port 630FLB/630M Adapter and configured to use Ethernet Jumbo frames may experience lower FCoE throughput if server traffic is oversubscribed(that is more than 20Gb) over the FlexFabric Adapter port and the server is only reading disks without writing them. This is because of

Ethernet traffic consuming excess bandwidth.

Workaround

Configure the server to use standard 1500 byte MTU frames. Alternatively, ensure that server traffic

(FCoE + Ethernet) doesn’t oversubscribe the port bandwidth of 20Gb.

Issue

If a single server is passing FCoE traffic and port monitoring is enabled, the FCoE traffic rate can drop significantly.

Issue

The VCM GUI does not redirect to the correct IP after a VC failover.

Workaround

The next failover succeeds without any issues. Refreshing the browser or closing and opening a new session redirects the browser to the correct IP address.

Issue

Issues and workarounds 7

Errors are received when changing an FCoE network to a different module in a VCEM environment.

Workaround

The customer must revert the changes, and then complete or cancel the domain maintenance mode. If the uplink must be changed to a different module, the customer can delete the existing network, and then re-create the network with the same name, but use different uplinks.

Issue

After configuring LDAP authentication, users logging in that do not have Domain role permissions receive an error when attempting to access the Local Users page. The error is only a notification because Local Users settings cannot be modified by users who do not possess Domain role permissions.

Issue

If an HP ProLiant BL870c i2 Server is present in bays 3 and 4 of a c3000 enclosure, then the Hardware

Overview page in VC Manager does not display the correct graphical picture of the server. VC Manager manages the server properly. It is only the graphical image that is incorrect.

Issue

In a VC domain with a VC profile assigned to a HP ProLiant BL2x220 Server Blade, when the I/O module connected to the dual-technology port is replaced with a module using single-blade technology, the OA detects that the identity of the server changed, but VC does not detect the change. As a result, the OA does not power on the server blade until VC updates the server configuration.

Workaround

To resolve the problem, unassign and reassign the profiles to the two server bays (for example, Bays 1a and 1b), perform a hot-plug install of the server, or simulate a hot-plug install of the server using the OA reset server command. The problem can also be resolved if VC restarts, fails over, reboots, receives a firmware update, or re-evaluates the server after an OA failover.

Issue

Under certain circumstances, the checkpoint status icon in the GUI persists for a long time and is not cleared.

The CLI also shows a "Checkpoint Status: Invalid" status in the show domain command output. This condition occurs periodically after a VCSU firmware upgrade of the VC module firmware.

Workaround

To resolve this issue, reset VCM on the primary module or reset the primary module using the OA.

Prerequisites

VC SR-IOV prerequisites: o

Supports the following adapters:

HP Flex-10 10Gb 2-port 530FLB Adapter

HP FlexFabric 10Gb 2-port 534FLB Adapter

HP Flex-10 10Gb 2-port 530M Adapter

HP FlexFabric 10Gb 2-port 534M Adapter

HP NC552m Flex-10 Adapter

Prerequisites 8

o

HP NC553m 10Gb 2-P FlexFabric Converged Network Adapter

HP FlexFabric 10Gb 2-port 554M Adapter

HP Flex-10 10Gb 2-port 552M Adapter

HP FlexFabric 10Gb 2-port 554FLB Adapter

HP FlexFabric 20Gb 2-port 630FLB Adapter

HP FlexFabric 20Gb 2-port 630M Adapter

Supports the following operating systems:

Windows 2012 (64-bit)

VMware ESXi 5.1 U2, 5.5 (64-bit)

RHEL 5.9 and 5.10 (64-bit with KVM)

RHEL 6.4 and 6.5 (64-bit with KVM)

SLES 11 SP2, SP3 (64-bit with KVM)

The lowest VCEM 7.3.0 support compatibility mode is set to VC 3.30.

If you are planning to use VC 4.21 firmware in a VCEM environment, HP recommends upgrading to

VCEM v7.3.0. For more information about the VC firmware that is compatible with VCEM, see the

Virtual Connect Enterprise Manager User Guide on the HP website

( http://h20000.www2.hp.com/bizsupport/TechSupport/DocumentIndex.jsp?contentType=Support

Manual&lang=en&cc=us&docIndexId=64179&taskId=101&prodTypeId=18964&prodSeriesId=360

1866 ).

Customers using Insight Control for VMware vCenter Server should upgrade to version 6.3 when using

Virtual Connect firmware version 3.30 and later. Version 6.3 fixes a known issue with version 6.2 where Virtual Connect data did not display correctly.

The Virtual Connect GUI requires a minimum of 512 MB of available memory to operate efficiently.

To operate with HP VC 8Gb 20-Port FC Modules, all HP Emulex LPe1205 8Gb FC HBAs that are revision A (identified by label EDC A-4904) must perform a CFL region 19 flash update. For download and installation instructions, see the LPe1205 product page on the HP website ( http://www.hp.com

).

Virtual Connect Manager version 4.21 requires Adobe Flash Player 11.1.x or higher before you can log in. HP recommends updating to Adobe Flash Player 11.5 or higher for Windows and 11.2 for Linux systems.

The recommended Adobe Flash Player web browser plug-in can be downloaded and installed from the

Adobe website ( http://get.adobe.com/flashplayer/ ), or downloaded as a standalone executable from the Adobe website ( http://www.adobe.com/downloads ).

For the latest Adobe Flash Player Security Bulletin Updates, see the Adobe website

( http://www.adobe.com/support/security/index.html#flashplayer ).

When VC 4.10 is configured in "IPv6 Only" mode, the OA "Enclosure IP Mode" must also be configured through the OA CLI or OA GUI. However, you must ensure that any OA IPv4 addresses are cleared or the VC module cannot function correctly. To recover, clear any OA IPv4 addresses using the

OA CLI or OA GUI, and then reset the VC module. For more information, see the "Enabling IPv6 support" section in the HP Virtual Connect for c-Class BladeSystem Version 4.20 User Guide in the

Virtual Connect Information Library ( http://www.hp.com/go/vc/manuals ).

Prerequisites 9

Installation instructions

To update the VC firmware, use the HP BladeSystem c-Class Virtual Connect Support Utility.

HP recommends that you always use the latest version available. For more information about VCSU, see the

HP BladeSystem c-Class Virtual Connect Support Utility release notes in the Virtual Connect Information

Library ( http://www.hp.com/go/vc/manuals ). To download the VC firmware and the VCSU utility, view the

BladeSystem for ProLiant Release Set Compatibility Table on the HP website

( http://www.hp.com/go/bladesystemupdates ) and select the appropriate download.

VC 4.21 supports SPP 2014.09.0, SPP 2014.06.0, SPP 2014.02.0 (B), and Maintenance Supplement

bundle for SPP 2014.02.0 B, but only for the features that are compatible between VC 4.21 and the corresponding SPPs. The VC 4.21 firmware can be downloaded separately from the HP website. HP also recommends using the most current updates for the firmware and drivers subsequent to the 2014.02.0 (B) release. When available, they can be obtained from the HP Single Point of Connectivity Knowledge (SPOCK) website ( http://www.hp.com/storage/spock ). The link to Virtual Connect is under the category "Other

Hardware" in the list of selections on the left.

Firmware upgrade requirements

IMPORTANT: When updating VC firmware, update each domain with the entire firmware package, which includes the individual VC-Enet and VC-FC firmware. Updating only the VC-Enet firmware or only the VC-FC firmware is not supported.

IMPORTANT: For VC 4.21 upgrades when Virtual Connect Enterprise Manager (VCEM) is in use, HP recommends upgrading to VCEM v7.3.0. For more information about the VC firmware that is compatible with VCEM, see the latest version of the Virtual Connect Enterprise Manager

User Guide on the HP website

( http://h20000.www2.hp.com/bizsupport/TechSupport/DocumentIndex.jsp?contentType=Su pportManual&lang=en&cc=us&docIndexId=64179&taskId=101&prodTypeId=18964&prodSe riesId=3601866 ).

Each HP Virtual Connect firmware package contains a separate HP VC-FC firmware version. The following tables show the version of VC-FC firmware included with each VC firmware package.

IMPORTANT: When upgrading the HP VC 4Gb FC firmware from version VC-FC 1.2x to version

VC-FC 1.4x, the VC-FC module can drop connectivity temporarily during the activation process.

A redundant customer configuration experiences a failover with no loss of application connectivity to the fabric.

Virtual Connect firmware v1.31 v1.32, v1.34 v2.01, v2.02 v2.10, v2.12 v2.30–v2.33 v2.34

VC 4Gb FC firmware within Virtual

Connect

1.20

1.21

1.30

1.32

1.40

1.41

VC 8Gb 20-Port FC firmware within Virtual

Connect

1.32

1.40

1.41

VC 8Gb 24-Port FC firmware within Virtual

Connect

1.00

1.01

1.01

Installation instructions 10

Virtual Connect firmware v3.0x v3.10, v3.15 v3.17, v3.18 v3.30 v3.51, v3.60, v3.70 v3.75 v4.01 v4.10 v4.20, v4.21

VC 4Gb FC firmware within Virtual

Connect

1.40

1.41

1.41

1.42

1.43

1.44

1.44

2.00

2.01

VC 8Gb 20-Port FC firmware within Virtual

Connect

1.40

1.41

1.41

1.42

1.43

1.44

1.44

2.00

2.01

VC 8Gb 24-Port FC firmware within Virtual

Connect

1.02

1.03

1.04

1.04

1.04

1.04

1.05

1.10

1.11

The following table shows firmware upgrade/downgrade support for the HP VC 4Gb FC Modules or HP VC

8Gb 20-Port FC Modules.

VC Versions To

1.31

To

1.32,

1.34

To

2.01,

2.02

To

2.10,

2.12

To v2.3x

To

3.0x

To

3.10,

3.15,

3.17,

3.18

To 3.30,

3.51,

3.60,

3.70,

3.75,

4.01,

4.10

To 4.20,

4.21

From VC 1.31

— Normal Fabric outage

*

From VC 1.32/1.34 Normal —

Fabric outage

*

From VC 2.01/2.02 Fabric outage

*

Fabric outage

*

From VC 2.10/2.12 Fabric outage

From VC 2.3x

*

Fabric outage

*

Fabric outage

*

Fabric outage

*

Fabric outage

*

Fabric outage

*

From VC 3.0x

From VC

3.10/3.15/

3.17/3.18

Fabric outage

*

Fabric outage

*

Fabric outage

*

Fabric outage

*

Fabric outage

*

Fabric outage

*

From VC

3.30/3.51/

3.60/3.70/3.75/

4.01/4.10

Fabric outage

*

Fabric outage

*

Fabric outage

*

From 4.20, 4.21

Fabric outage

*

Fabric outage

*

Fabric outage

*

Fabric outage

*

Fabric outage*

Fabric outage

*

Fabric outage

*

Fabric outage*

Fabric outage

Fabric outage*

Fabric outage

Fabric outage

Fabric outage*

* * *

Normal Normal Normal Normal Normal

Fabric outage

*

Fabric outage

*

Fabric outage

*

Fabric outage

*

Fabric outage

*

Normal Normal Normal Normal

Fabric outage*

Fabric outage*

Fabric outage*

Fabric outage*

Normal Normal Normal

Fabric outage

*

Fabric outage

*

Fabric outage

*

Normal Normal

Fabric outage

*

Fabric outage

*

Normal

Fabric outage*

Fabric outage*

Fabric outage*

Fabric outage*

Fabric outage*

Fabric outage*

Fabric outage*

Fabric outage*

Fabric outage*

Installation instructions 11

* Always reset the module after the upgrade or downgrade.

On HP Virtual Connect 4Gb Fibre Channel Modules (with enhanced NPIV), downgrading the firmware to any version older than VC 2.10 is not supported.

Firmware version for HP BladeSystem for ProLiant

The firmware versions and software versions listed in this section have been tested as a solution set using HP

Maintenance Supplement Bundle for SPP 2014.02.0, version 2014.04 as a baseline, and are fully supported by HP. VC 4.21 supports SPP 2014.09.0, SPP 2014.06.0, SPP 2014.02.0 (B), and Maintenance

Supplement Bundle for SPP 2014.02.0 B, but only for the features that are compatible between VC 4.21 and the corresponding SPPs. For best results, follow the pre-deployment planning steps in the HP Virtual Connect

for c-Class BladeSystem Setup and Installation Guide and the HP BladeSystem ProLiant Firmware

Management Best Practices Implementer Guide on the HP website

( http://h18004.www1.hp.com/products/servers/service_packs/documentation/index.html

) to deploy the baseline set with component updates.

HP Service Pack for ProLiant is the replacement product for Insight Foundation (PSPs, Smart Update Firmware

DVD, and other systems software). To download the update, see the HP Service Pack for ProLiant website

( http://www.hp.com/go/spp ).

CAUTION: HP recommends using the specific firmware and software versions listed together to ensure complete solution component compatibility and full functionality. These versions have been tested as a set. Using other version levels might result in operational issues.

Baseline Firmware Release Set

The contents of HP Maintenance Supplement Bundle for SPP is documented in the HP Maintenance

Supplement Bundle for SPP Release Notes and HP Maintenance Supplement Bundle for SPP Server Support

Guide on the HP website

( http://h18004.www1.hp.com/products/servers/service_packs/documentation/index.html

).

Additional information

Versions 3.15 and higher of HP Virtual Connect Manager check the server ROM image version and display an incompatible state only for server blades that have a VC Server Profile assigned and are using incompatible server ROM versions.

Virtual Connect does not have the capability to perform version checking of the mezzanine card firmware.

Validate this information through server POST for mezzanine support utilities.

Server blades and mezzanine cards that do not meet the required firmware versions do not accept Virtual

Connect-assigned parameters such as MACs and WWNs properly and therefore maintain factory defaults.

However, these server blades do have the Ethernet network and Fibre Channel fabric connectivity specified in their Virtual Connect server profiles. This connectivity enables you to use network-based firmware update tools for server blade and mezzanine firmware updates.

For Virtual Connect Fibre Channel and FlexFabric modules, the supported firmware and OS drivers are listed in the HP Single Point of Connectivity Knowledge (SPOCK) website ( http://www.hp.com/storage/spock ).

The link to Virtual Connect is under the category "Other Hardware" in the list of selections on the left.

Firmware version for HP BladeSystem for Integrity

To obtain HP BladeSystem Release Sets for Integrity, see the HP website

( http://h18004.www1.hp.com/products/blades/integrity-release-sets.html

).

Installation instructions 12

Important notes

A serious issue that could cause a network outage when upgrading directly from VC 2.xx release version to VC 4.20 release in a Multi-Enclosure environment. Upgrade from VC 2.xx to VC 3.70 or VC

4.10 first, and then upgrade from VC 3.70 or VC 4.10 to VC 4.20 in a Multi-Enclosure setup.

At a minimum, use of IPv6 requires the SPP 2013.09.0 (B) release. The minimum OA firmware version required is 4.01, and the minimum iLO 4 firmware version required is 1.30.

FCoE protocol, which includes FIP Snooping, is not supported on uplinks with SFP-LR transceivers.

Any configuration using Integrity server blades should only use OA firmware version 3.60. For more information, see the HP website

( https://h20566.www2.hp.com/portal/site/hpsc/template.PAGE/public/kb/docDisplay/?docId=e mr_na-c03613140 ).

When connecting a Virtual Connect FlexFabric 10Gb/24-port Module directly to 3PAR storage systems in the VC multi-enclosure environment, a server profile migration of a SAN-booted server between enclosures is not supported. Similarly, in the domains managed by Virtual Connect Enterprise Manager

(VCEM), a server profile migration of a SAN-booted server between enclosures is not supported.

To perform a server profile migration of a SAN-booted server between enclosures directly attached to a 3PAR storage system in the VC multi-enclosure environment, the following manual steps are required: a.

Power off the server. b.

Un-assign the server profile. c. d. e.

Change the Primary and Secondary Target WWNs in the FC Boot Parameters section of the profile to reflect the WWNs of the 3PAR storage array ports directly connected to the destination enclosure.

Assign the profile to the destination location.

Power on the destination server.

Although the GUI enables the selection of SNMP v2 traps, the VC 4Gb FC Module and the VC 8Gb

20-Port FC Module remain as v1 traps.

During OA failover or other management network disruptions, VC SNMP traps might not reach the management station.

Changes in the server RBSU can override Virtual Connect server profile settings for PXE (enabled or disabled). If you make a change in RBSU, that change is not reflected in Virtual Connect Manager. If you set PXE through RBSU, HP recommends using the "Use-BIOS" setting.

The latest version of the VC-specific MIBs, 9.50 or higher, can be downloaded from the HP Systems

Insight Manager "MIB Kit" site on the HP website

( http://h18006.www1.hp.com/products/servers/management/hpsim/mibkit.html

).

The LLDP-MIB and LLDPv2 MIB files can be downloaded directly from IEEE: o

LLDP-MIB ( http://www.ieee802.org/1/files/public/MIBs/LLDP-MIB-200505060000Z.txt

) o o

LLDP-V2-MIB ( http://www.ieee802.org/1/files/public/MIBs/LLDP-V2-MIB-200906080000Z.txt

)

LLDP-V2-TC-MIB

( http://www.ieee802.org/1/files/public/MIBs/LLDP-V2-TC-MIB-200906080000Z.txt

)

Important notes 13

To access Virtual Connect documentation for current and past releases, see the HP website

( http://h18004.www1.hp.com/products/blades/components/c-class-tech-installing.html

).

Important notes 14

Acronyms and abbreviations

FCoE

Fibre Channel over Ethernet

LLDP

Link Layer Discovery Protocol

MIB management information base

OA

Onboard Administrator

SPP

HP Service Pack for ProLiant

VC

Virtual Connect

VCEM

Virtual Connect Enterprise Manager

VCM

Virtual Connect Manager

VCSU

Virtual Connect Support Utility

WWN

World Wide Name

Related information

Virtual Connect Enterprise Manager support

Acronyms and abbreviations 15

For information about the VC firmware that is compatible with VCEM, see the latest version of the Virtual

Connect Enterprise Manager User Guide on the HP website

( http://h20000.www2.hp.com/bizsupport/TechSupport/DocumentIndex.jsp?contentType=SupportManu al&lang=en&cc=us&docIndexId=64179&taskId=101&prodTypeId=18964&prodSeriesId=3601866 ).

Documentation feedback

HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback ( mailto:[email protected]

).

Include the document title and part number, version number, or the URL when submitting your feedback.

Related information 16