HP Smart Array P822 Controller


Add to my manuals
19 Pages

advertisement

HP Smart Array P822 Controller | Manualzz

QuickSpecs

Overview

HP Smart Array P822 Controller

The HP Smart Array P822 Controller is a Full height, 6 Gb/s, PCIe 3.0, Serial Attached SCSI (SAS) RAID controller that provides enterprise class, second generation storage performance, maximum external scalability, and data protection for select HP ProLiant Gen8 rack servers and tower servers.

It features two internal and four external SAS ports. Advanced storage functionality, including online RAID level migration with flash backed write cache (FBWC), global online spare, and pre-failure warning all result in increased server uptime. Data compatibility gives customers an easy upgrade path to future Smart Array Controllers.

HP Smart Array Advanced Pack 2.0 is included with this controller providing advanced functionality, including features such as RAID 1

ADM (Advanced Data Mirroring), making it easier for customers to protect their data.

What's New

HP SmartCache is base feature of this controller that improves application workload performance by caching hot data to SSDs

Up to 4x better Solid State Disk (SSD) read performance with the SSD Smart Path firmware and driver based feature for Smart

Array controllers

DA - 14341 Worldwide — Version 12 — April 18, 2014 Page 1

QuickSpecs

Overview

Models

HP Smart Array P822

Controller

HP Smart Array P822 Controller

HP Smart Array P822/2GB FBWC 6Gb 2-ports-Int/4-ports Ext SAS Controller 615418-B21

DA - 14341 Worldwide — Version 12 — April 18, 2014 Page 2

QuickSpecs

Standard Features

The Smart Array

Advantage

HP Smart Array P822 Controller

HP's innovative design and integration work of the Smart Array family of products creates customer value that is unmatched in the industry. Use of Smart Array products across multiple applications results in a much lower Total Cost of Ownership (TCO) than any other server storage RAID product. The HP Smart Array family brings an unparalleled return on investment through:

Data Compatibility

among all models of Smart Array controllers allows simple and easy upgrades any time needs for higher performance, capacity, and availability increase. Even successive generations of

Smart Array controllers understand the data format of other Smart Array Controllers.

Consistent Configuration and Management Tools

. All Smart Array products utilize a standard set of management and utility software. These tools minimize Total Cost of Ownership (TCO) by reducing training requirements and technical expertise necessary to install and maintain the HP server storage.

Universal Drive

form factors (2.5" and 3.5") are used across multiple HP servers, disk enclosures and storage systems. With compatibility across many enterprise platforms, you are free to deploy and redeploy these drives to quickly deliver increased storage capacity, migrate data between systems, and easily manage spare drives.

Smart Carrier

is used across multiple HP Servers. With compatibility across many enterprise platforms, you are free to deploy and re-deploy these drives to quickly deliver increased storage capacity, migrate data between systems, and easily manage spare drives.

Pre-Failure Warranty

means HP Insight Manager not only reports when a drive is going to fail but allows replacement of failing drives prior to actual failure. For complete details, consult the HP Support Center or refer to your HP Server documentation.

Key Features

Seamless upgrades to and from other HP Smart Array controllers.

Storage interface (SAS/SATA)

Two Mini SAS 4i connectors for attachment to internal drive backplanes

Four Mini SAS 4x connectors for attachment to JBODs and external tape drives

6 Gb/s SAS technology delivers up to 600 MB/s per physical link.

6 Gb/s SATA technology delivers up to 600 MB/s for directly attached SATA drives.

Mix-and-match SAS and SATA drives. Deploy drive technology as needed to fit the computing environment.

Support for SAS tape drives, SAS tape autoloaders and SAS tape libraries.

Host interface (PCI-e)

PCI-e 3.0 8x host interface provides up to 8 GiB/s in each direction

RAID controller features

2GB flash-backed write cache (not all of which is available for user data)

RAID 0, 1, 1+0, 5, 6, 50, 60, and 1 ADM

Recovery ROM protects against ROM corruption

Smart Array Advanced Pack 2.0 license key included (see below)

The HP SSD Smart Path feature included in the Smart Array software stack improves SSD read performance by bypassing the Smart Array firmware for the optimal performance path to the SSD.

The HP SmartCache licensed feature (available as an additional option) is a controller-based read caching solution in a DAS environment that caches the most frequently accessed data ("hot" data) onto lower latency SSDs to dynamically accelerate application workloads.

Consistent management software among all Smart Array family products, including Array

Configuration Utility (ACU), Systems Insight Manager (SIM), Array Diagnostic Utility (ADU), Online

ROM Configuration Utility (ORCA), and Intelligent Provisioning

SAS 2.0 (6 Gb/s, 3 Gb/s, and 1.5 Gb/s). 6 Gb/s bandwidth supports larger numbers of SAS drives in the SAS subsystem and provides better support for future high-bandwidth SSDs.

SATA 2.6 (6 Gb/s and 3 Gb/s)

DA - 14341 Worldwide — Version 12 — April 18, 2014 Page 3

QuickSpecs

Standard Features

HP Smart Array P822 Controller

24 SAS/SATA physical links distributed across six Mini SAS connectors

Two Mini SAS 4i connectors (8 physical links): for attachment to internal drive backplanes

Four Mini SAS 4x connectors (16 physical links): for attachment to JBODs and external tape drives

Storage Interface

(SAS/SATA)

Host Interface

(PCI-e)

RAID Processor and

Expander

Interface Speeds

PCI-e 3.0 (8 GT/s)

Eight lane mechanical connector

Electrically supports one, four, and eight lanes

P822 includes a Sierra SRCv 8x6G SAS RAID-on-chip featuring:

Eight SAS/SATA physical links, each supporting 6 and3 Gb/s for SAS and SATA protocol

Eight PCI-e 3.0 lanes each supporting 8 Gb/s

DDR3-1600 MHz memory controller

High performance MIPS-based multi-processor subsystem

Hardware XOR and Reed-Solomon Engines for RAID 5 and RAID 6 acceleration

The P822 2GB array accelerator features a flash-backed write cache. If the cache DRAM contains data when power is lost, the data is copied into flash memory of the cache module, drawing power from attached capacitors. When power is restored, if the flash memory chips contain write data, the data is copied back into the DRAM so it can be flushed to the drives.

Advantages over battery-backed cache architectures include:

No 72-hour deadline for retrieving the data before the batteries fully discharge

Capacitors charge faster than batteries; controller disables the write cache for only a few minutes waiting for capacitors to charge rather than a few hours waiting for batteries to charge

No need for periodic battery replacement

No special disposal process

P822 supports the latest interface speed

Interface

PCI-e

SAS/SATA

RAID cache

Maximum bandwidth

*

8 GiB/s (in each direction)

14.4GiB/s (in each direction)

2 GB/s

* Not counting protocol overhead.

Notes

PCI-e 3.0 (8 lanes at 8 GT/s)

SAS-2 (24 physical links at 6 Gb/s)

DDR3-1600 MHz SDRAM (64-bit data and 8bit ECC)

DA - 14341 Worldwide — Version 12 — April 18, 2014 Page 4

QuickSpecs

HP Smart Array P822 Controller

Standard Features

Native Command Queuing

(NCQ)

Native Command Queuing (NCQ) is a technology designed to increase performance of SATA hard disk drives by allowing the individual hard disk to internally optimize the order in which received read and write commands are executed. This can reduce the amount of unnecessary going back-and-forth on the drive's heads, resulting in increased performance for workloads where multiple simultaneous read/write requests are outstanding, most often occurring in server or storage-type applications. Without NCQ the drive has to process and complete one command at a time. For NCQ to be enabled, it must be supported and turned on in the controller and in the hard drive itself.

Native Command Queuing (NCQ) is a technology designed to increase performance of SATA hard disk drives by allowing the individual hard disk to internally optimize the order in which received read and write commands are executed. This can reduce the amount of unnecessary going back-and-forth on the drive's heads, resulting in increased performance for workloads where multiple simultaneous read/write requests are outstanding, most often occurring in server or storage-type applications. Without NCQ the drive has to process and complete one command at a time. For NCQ to be enabled, it must be supported and turned on in the controller and in the hard drive itself.

NOTE:

Please see the SATA Hard Drive QuickSpecs for specific SATA hard drive capacities that support NCQ: http://h18000.www1.hp.com/products/quickspecs/13021_div/13021_div.html

Dual Domain Support

Number of Drives

RAID Levels

Dual domain SAS creates redundant pathways for external drives from servers to storage devices. The redundant paths created by these configurations reduce or eliminate single points of failure within the storage network. This provides increased levels of high availability with redundant paths from the controller to the drives. Dual domain SAS implementations make it possible to tolerate host bus adapter

(HBA) or controller failure, external cable failure, expander failure, cable pulls, expander failure and failure in a spanned disk (JBOD) environments.

P822 supports up to 227 drives. Examples:

27 internal drives plus eight HP D2700 Disk Enclosures with 25 drives each (227 drives)

27 internal drives plus eight HP D2600 Disk Enclosures with 12 drives each (123 drives)

RAID 0 (striping)

provides no extra data protection. Data is striped across all drives in the array to increase performance. RAID 0 requires a minimum of one drive.

RAID 1 (mirroring)

protects against failure of one drive. Data is duplicated on a pair of drives. RAID 1 requires a minimum of two drives. Also see the Advanced Pack Mirror Splitting and Combining feature.

RAID 1+0 (mirroring and striping)

protects against failure of one drive (and failure of particular multiple drives). RAID 1+0 is a nested RAID method that uses RAID 0 striping across RAID 1 arrays to provide performance and protection. RAID 1+0 requires a minimum of four drives. Also see the

Advanced Pack Mirror Splitting and Combining feature.

RAID 5 (distributed data guarding)

protects against failure of one drive. Data protection is provided by parity data distributed across all the drives. When a physical drive fails, data that was on the failed drive can be calculated from the remaining parity data and user data on the other drives in the array. This recovered data is usually written to an online spare drive through a process called a rebuild. RAID 5 requires a minimum of three drives.

RAID 6 with ADG

(Advanced Data Guarding): This is the highest level of fault tolerance. It allocates two sets of parity data across drives and allows simultaneous write operations. This level of fault tolerance can withstand two simultaneous drive failures without downtime or data loss.

DA - 14341 Worldwide — Version 12 — April 18, 2014 Page 5

QuickSpecs

Standard Features

HP Smart Array P822 Controller

RAID 50 (RAID 5+0)

protects against failure of one drive (and failure of particular multiple drives).

RAID 50 is a nested RAID method that uses RAID 0 striping across RAID 5 arrays. RAID 50 tolerates one drive failure in each spanned array without loss of data. RAID 50 requires less rebuild time than single RAID 5 arrays RAID 50 requires a minimum of six drives.

RAID 60 (RAID 6+0)

allows administrators to split the RAID 6 storage across multiple external boxes. RAID 60 requires a minimum of eight drives. RAID 60 is a nested RAID method that uses RAID

0 block-level striping across multiple RAID 6 arrays with dual distributed parity. With the inclusion of dual parity, RAID 60 will tolerate the failure of two disks in each spanned array without loss of data.

RAID 1 ADM (Advanced Data Mirroring)

allows customers to create mirrored RAID set using 3 identical hard drives. This provides customers with a 2nd "live spare" for RAID 1(+0) configurations.

This allows customers to rebuild a failed drive in a RAID 1(+0) set without the array entering into a degraded state.

Online Management

Features

Availability

Online Capacity Expansion (increase array size feature)

Advanced Capacity Expansion (shrink array and move array features)

Online RAID Level Migration (change the fault tolerance level of a configured logical drive)

Online Stripe Size Migration (change the stripe size of a configured logical drive)

Online Spares (provide automatic drive replace for a failed drive in RAID levels other than RAID 0)

User Selectable Expand and Rebuild Priority (select the priority of rebuilding data from a failed drive over current requests from the operating system)

User Selectable Stripe Size

User Selectable Read and Write Cache Sizes

Logical Drive Extension (increase logical drive size without disturbing data)

User Selectable Surface Scan idle interval (control the background process that scans drives for bad sectors, and verify the consistency of RAID 5 and RAID 6 parity data)

Physical Drive Write Cache control (enable drive write cache for applications like video editing that that can tolerate data loss, and/or systems that have redundant and uninterruptible power supplies)

Provides increased server uptime by providing advanced storage functionality:

Online RAID Level Migration (between any RAID level)

Online Capacity Expansion

Logical Drive Capacity Extension

Global Online Spare

Pre-Failure Warranty

DA - 14341 Worldwide — Version 12 — April 18, 2014 Page 6

QuickSpecs

Standard Features

Fault Prevention

HP Smart Array P822 Controller

The following features offer detection of possible failures before they occur, allowing preventive action to be taken:

S.M.A.R.T.: Self Monitoring Analysis and Reporting Technology first developed at HP detects possible hard disk failure before it occurs, allowing replacement of the component before failure occurs.

Drive Parameter Tracking monitors drive operational parameters, predicting failure and notifying the administrator.

Dynamic Sector Repairing continually performs background surface scans on the hard disk drives during inactive periods and automatically remaps bad sectors, ensuring data integrity.

Smart Array Cache Tracking monitors integrity of controller cache, allowing pre-failure preventative maintenance.

Environment Tracking for External Storage System: Monitors fan speed and cabinet temperature of

Modular Smart Array Enclosures.

Fault Recovery

Ease of Use

HP SSD SmartPath

HP SmartCache

Minimizes downtime, reconstructs data, and facilitates a quick recovery from drive failure

Recovery ROM: This feature provides unique redundancy that protects from a ROM image corruption. A new version of firmware can be flashed to the ROM while the controller maintains the last known working version of firmware. If the firmware becomes corrupt, the controller will revert back to the previous version of firmware and continue operating. This reduces the risk of flashing firmware to the controller.

On-Line Spares: There is no limit to the number of spare drives that can be installed prior to drive failure. If a failure occurs, recovery begins with an On-Line Spare and data is reconstructed automatically.

DRAM ECC corrects against single bit data and address corruption.

Consistency and Upgradeability make the Smart Array family unique in the industry:

GUI based configuration, management and diagnostic software tools

Common data format between generations of products

Data migration between servers and external Modular Smart Array enclosures

The HP SSD Smart Path feature included in the Smart Array software stack improves Solid State Disk (SSD) read performance. The Smart Array driver chooses the optimum path to access each SSD. With up to 4x better SSD read performance, HP SSD Smart path chooses the optimum path to the SSD and accelerates reads for all RAID levels and RAID 0 writes. HP SSD Smart Path Requires updated firmware, drivers, and configurable utility available here: www.hp.com/go/HPSSDSmartPath . HP SSD Smart Path is ideal for read intensive workloads and is included as a base feature on HP Smart Array P-series controllers. The following operating systems are supported by the HP SSD Smart Path feature

Microsoft Windows 2008 Server

Microsoft Windows 2008 R2 Server

Microsoft Windows 2012 Server

The HP SmartCache licensed feature is a controller-based read caching solution in a DAS environment that caches the most frequently accessed data ("hot" data) onto lower latency SSDs to dynamically accelerate application workloads. HP SmartCache is supported on HP ProLiant Gen8 servers with one of the following controllers: P420i, P420, P421, P822 and P721m. HP SmartCache is an included feature on the P822 and

DA - 14341 Worldwide — Version 12 — April 18, 2014 Page 7

QuickSpecs

Standard Features

HP Smart Array P822 Controller

P721m/2G FBWC. The HP SmartCache architecture is flexible and supports any HP ProLiant Gen8 supported HDD for bulk storage and any HP ProLiant Gen8 supported SSD as an accelerator.

The basic HP SmartCache architecture is comprised of the following three elements:

Bulk storage:

The first element is the bulk storage device, which is any supported HDD attached to the HP Smart Array controller.

Accelerator

: The second element, the accelerator, is a faster/lower latency SSD device that caches data.

Metadata:

The final element is metadata, information held in a relatively small storage area that maps the location of information residing on the accelerator and bulk storage devices.

HP SmartCache is deployed and managed through the same management tool for HP Smart Array - the HP

Array Configuration Utility (ACU). For more information please visit www.hp.com/go/smartcache

Warranty

The warranty for this device is 3 years parts only.

Pre-Failure Warranty

: Drives attached to the Smart Array Controller and monitored under Insight Manager are supported by a Pre-Failure (replacement) Warranty. For complete details, consult the HP Support

Center or refer to your HP Server Documentation.

Warranty Upgrade Options

Response - Upgrade on-site response from next business day to same day 4 hours

Coverage - Extend hours of coverage from 9 hours x 5 days to 24 hours x 7 days

Duration - Select duration of coverage for a period of 1, 3, or 5 years

Warranty upgrade options can come in the form of Care Packs, which are sold at the HP System level this product attaches too

DA - 14341 Worldwide — Version 12 — April 18, 2014 Page 8

QuickSpecs

Compatibility

Servers

HP Smart Array P822 Controller

For up to date compatibility, please see the following URL for complete Smart Array P800/512MB

Controller compatibility and support information: http://h18006.www1.hp.com/products/servers/proliantstorage/arraycontrollers/index.html

Operating Systems

Software Suite

Microsoft Windows Server

Microsoft Windows Server Hyper-V

Red Hat Enterprise Linux (RHEL)

SUSE Linux Enterprise Server (SLES)

VMware

NOTE:

For more information on HP's Certified and Supported ProLiant Servers for OS and Virtualization

Software and the latest listing of software drivers available for your server and Smart Array RAID controller, please visit our Support Matrix at: http://www.hp.com/go/ossupport

NOTE: For more Linux OS support and certification information, please visit: http://h18004.www1.hp.com/products/servers/linux/

All Smart Array products share a common set of configuration, management and diagnostic tools. This software consistency of tools reduces the cost of training for each successive generation of product and takes much of the guesswork out of troubleshooting field problems. These tools lower the total cost of ownership by reducing training and technical expertise necessary to install and maintain HP server storage.

HP Systems Insight Manager

(SIM)

Provides the basic management features of system discovery and identification, single-event view, inventory data collection, and reporting

Monitors over 1200 system wide parameters

Smart Array performance monitoring

Smart Array drive fault prediction

HP Array Configuration Utility

(ACU)

Powerful Web based configuration utility for all Smart Array controllers

Provides a graphical view of HP drive array configurations

Allows for management of multiple arrays over a secure Internet connection from anywhere in the world

Easy to use Wizards for configuration

Command line interface (ACU-CLI) also available

Runs offline for all supported operating systems

Runs online on Windows and linux

For online configuration on NetWare, use CPQONLIN

HP Option ROM Configuration for Arrays

(ORCA)

ROM-based utility accessed by pressing F8 during system power up

View, create, and delete arrays and logical volumes and assign an online spare drive

Select the boot controller

For more advanced array configurations, use ACU

HP Array Diagnostic Utility

(ADU)

In depth diagnostic and reporting utility for all Smart Array controllers

Integrated with ACU

Runs offline for all supported operating systems

Runs online for Windows and Linux

HP Smart Array SAS/SATA Event Notification Service

(CISSESRV)

DA - 14341 Worldwide — Version 12 — April 18, 2014 Page 9

QuickSpecs

Compatibility

HP Smart Array P822 Controller

Provides event notification to the Windows Server 2003 and Windows Server 2008 system event log and HP ProLiant integrated management log

HP Smart Array Advanced

Pack 2.0

(license key included with P822)

RAID 6 (Advanced Data Guarding) protects against failure of any two drives. RAID 6 requires a minimum of four drives. ADG can tolerate multiple simultaneous drive failures without downtime or data loss and is ideal for applications requiring large logical volumes, because it can safely protect a single volume of up to 56 disk drives. RAID 6 also offers lower implementation costs and greater usable capacity per U than RAID 1.

RAID 60 (RAID 6+0) allows administrators to split the RAID 6 storage across multiple external boxes.

RAID 60 requires a minimum of eight drives. RAID 60 is a nested RAID method that uses RAID 0 block-level striping across multiple RAID 6 arrays with dual distributed parity. With the inclusion of dual parity, RAID 60 will tolerate the failure of two disks in each spanned array without loss of data.

Advanced Capacity Expansion automates higher capacity migration using capacity transformation to remove logical drives by shrinking and then expanding them online. Standard drive migration and expansion remain unchanged.

Mirror Splitting and Recombining. Mirror splitting is a task that splits an array with one or more RAID

1 or RAID 1+0 logical drives into two identical new arrays with RAID 0 logical drives. This is useful for administrators who want to replicate a configuration or need to build a backup before performing a risky operation. Using the ACU, administrators can also recombine a split mirrored array.

Drive Erase completely erases physical disks or logical volumes. This capability is useful when decommissioning, redeploying, or returning hard drives. Provides three patterns:

One pass erase: Write zeros

Two pass erase: Write random data, then zeros

Three pass erase: Write random data, random data, then zeros

Video On Demand Performance Optimization optimizes performance of video on demand and improves latency during video streaming. Provides controls for:

RAID 6/60 Alternate Inconsistency Repair Policy

RAID 5/6/50/60 Degraded Mode Performance Optimization

Physical Drive Request Elevator Sort

Monitor and Performance Analysis Delay

Maximum Drive Request Queue Depth

HP SmartCache - controller base caching to improve workload performance available when updating to the latest HP firmware. Please see www.hp.com/go/smartcache for more details

NOTE:

HP SmartCache requires the following: Min 1 or 2 GB FBWC module along with HP ProLiant

Gen8 supported HDD(s) and SSD(s) for more information visit: www.hp.com/go/smartcache

DA - 14341 Worldwide — Version 12 — April 18, 2014 Page 10

QuickSpecs

Service and Support

Service and Support

HP Smart Array P822 Controller

HP Technology Services

HP Technology Services offers you technical consultants and support expertise to solve your most complex infrastructure problems. We help keep your business running, boost availability, and avoid downtime.

Protect your business beyond warranty with HP Care Pack Services

When you buy HP Options, it's also a good time to think about what level of service you may need. HP Care

Pack services provide total care and support expertise with committed response choices designed to meet your IT and business need.

HP Foundation Care services deliver scalable support-packages for HP industry-standard servers and software. You can choose the type and level of service that is most suitable for your business needs. New to this portfolio is HP Collaborative Support. If you are running business critical environments, HP offers

Proactive Care or Critical Advantage. These services help you deliver high levels of application availability through proactive service management and advanced technical response.

Here is the support service recommendation from the Foundation Care and Proactive Care portfolio. For customized support service solution, HP can work with you to tailor a service solution for your unique support requirements using broader services portfolio of Foundation Care and Proactive Care.

Recommended HP Care Pack Services for optimal satisfaction with your HP product

Recommended Services 3-Year HP 24x7 4 hour Response, Proactive Care

Helps optimize your systems and delivers high levels of application availability through proactive service management and advanced technical response. A skilled Technical Manager will own your query or issue end to end until resolved, delivering a single point of contact for you

OR

3-Year HP 24x7 4 hour Response, HP Collaborative Support

Provides problem resolution support across the stack of HW, firmware, and HP and 3rd party SW. In case the issue is with 3rd party SW, HP does known issue resolution. If HP cannot solve the issue, it will contact the third-party vendor and create a problem incident on your behalf http://h20195.www2.hp.com/V2/GetPDF.aspx/4AA3-8232ENW.pdf

HP Installation of ProLiant Add On Options Service

This easy-to-buy, easy-to-use HP Care Pack service helps ensure that your new HP hardware or software is installed smoothly, efficiently, and with minimal disruption of your IT and business operations

DA - 14341 Worldwide — Version 12 — April 18, 2014 Page 11

QuickSpecs

HP Smart Array P822 Controller

Service and Support

Related HP Care Pack Services to enhance your HP product experience

Related Services 3-Year HP 24x7 4 hour Response, Proactive Care

Helps optimize your systems and delivers high levels of application availability through proactive service management and advanced technical response. A skilled Technical Manager will own your query or issue end to end until resolved, delivering a single point of contact for you

OR

3-Year HP 24x7 4 hour Response, Hardware Support Onsite Service

Provides you with rapid remote support and if required an HP authorized representative who will arrive on site any time and day of the year to begin hardware maintenance service within 4 hours of the service request being logged http://h20195.www2.hp.com/V2/GetPDF.aspx/5982-6547EEE.pdf

3-Year HP 6-hour Onsite Call-to-Repair, HP Collaborative Support

Offers customers a single point of contact for server problem diagnosis, hardware problem resolution to return the hardware in operating condition within 6 hours of the initial service request to the HP Global

Solution Center, and basic software problem diagnosis, fault isolation, and resolution if available to HP.

http://h20195.www2.hp.com/V2/GetPDF.aspx/4AA3-8232ENW.pdf

HP Proactive Select Service

Provides a flexible way to purchase HP best-in-class consultancy and technical services. You can buy

Proactive Select Service Credits when you purchase your hardware and then use the credits over the next

12 months. http://h20195.www2.hp.com/V2/GetPDF.aspx/4AA2-3842ENN.pdf

Insight Remote Support

Provides 24 X 7 remote monitoring, proactive notifications, and problem resolution. Learn more http://www.hp.com/go/insightremotesupport

HP Support Center

Personalized online support portal with access to information, tools and experts to support HP business products. Submit support cases online, chat with HP experts, access support resources or collaborate with peers. Learn more http://www.hp.com/go/hpsc

HP's Support Center Mobile App * allows you to resolve issues yourself or quickly connect to an agent for live support. Now, you can get access to personalized IT support anywhere, anytime.

HP Insight Remote Support and HP Support Center are available at no additional cost with a HP warranty,

HP Care Pack or HP contractual support agreement.

*HP' Support Center Mobile App is subject to local availability

Parts and materials

HP will provide HP-supported replacement parts and materials necessary to maintain the covered hardware product in operating condition, including parts and materials for available and recommended engineering improvements. Supplies and consumable parts will not be provided as part of this service; standard warranty terms and conditions apply. Parts and components that have exceeded their maximum supported lifetime and/or the maximum usage limitations as set forth in the manufacturer's operating manual or the technical product data sheet will not be provided, repaired or replaced as part of this service.

DA - 14341 Worldwide — Version 12 — April 18, 2014 Page 12

QuickSpecs

HP Smart Array P822 Controller

Service and Support

Warranty / Service

Coverage

For ProLiant servers and storage systems, this service covers HP-branded hardware options qualified for the server, purchased at the same time or afterward, internal to the enclosure, as well as external monitors up to 22" and tower UPS products; these items will be covered at the same service level and for the same coverage period as the server unless the maximum supported lifetime and/or the maximum usage limitation has been exceeded. Coverage of the UPS battery is not included; standard warranty terms and conditions apply.

The defective media retention service feature option applies only to Disk or eligible SSD/Flash Drives replaced by HP due to malfunction. It does not apply to any exchange of Disk or SSD/Flash Drives that have not failed. SSD/Flash Drives that are specified by HP as consumable parts and/or that have exceeded maximum supported lifetime and/or the maximum usage limit as set forth in the manufacturer's operating manual or the technical data sheet are not eligible for the defective media retention service feature option.

For more information

To learn more on services for HP ESSN Options, please contact your HP sales representative or HP

Authorized Channel Partner. Or visit: http://www.hp.com/services/proliant or www.hp.com/services/bladesystem

DA - 14341 Worldwide — Version 12 — April 18, 2014 Page 13

QuickSpecs

Related Options

HP Smart Array P822 Controller

NOTE:

This is a list of supported options. Some may be discontinued.

Hard Drives HP SAS Hot Plug SmartDrive Carriers for Gen8 Servers only

SAS Hot Plug with SmartDrive SFF (2.5-inch) Enterprise Drives

HP 1.2TB 6G SAS 10K rpm SFF (2.5-inch) SC Enterprise 3yr Warranty Hard Drive

HP 900GB 6G SAS 10K rpm SFF (2.5-inch) SC Enterprise 3yr Warranty Hard Drive

HP 600GB 6G SAS 10K rpm SFF (2.5-inch) SC Enterprise 3yr Warranty Hard Drive

HP 450GB 6G SAS 10K rpm SFF (2.5-inch) SC Enterprise 3yr Warranty Hard Drive

HP 300GB 6G SAS 10K rpm SFF (2.5-inch) SC Enterprise 3yr Warranty Hard Drive

HP 300GB 6G SAS 15K rpm SFF (2.5-inch) SC Enterprise 3yr Warranty Hard Drive

HP 146GB 6G SAS 15K rpm SFF (2.5-inch) SC Enterprise 3yr Warranty Hard Drive

SAS Hot Plug SmartDrive SFF (2.5-inch) Midline Drives

HP 1TB 6G SAS 7.2K rpm SFF (2.5-inch) SC Midline 1yr Warranty Hard Drive

HP 500GB 6G SAS 7.2K rpm SFF (2.5-inch) SC Midline 1yr Warranty Hard Drive

SAS Hot Plug SmartDrive LFF (3.5-inch) Enterprise Drives

HP 600GB 6G SAS 15K rpm LFF (3.5-inch) SC Enterprise 3yr Warranty Hard Drive

HP 450GB 6G SAS 15K rpm LFF (3.5-inch) SC Enterprise 3yr Warranty Hard Drive

SAS Hot Plug SmartDrive LFF (3.5-inch) Midline Drives

HP 4TB 6G SAS 7.2K rpm LFF (3.5-inch) SC Midline 1yr Warranty Hard Drive

HP 3TB 6G SAS 7.2K rpm LFF (3.5-inch) SC Midline 1yr Warranty Hard Drive

HP 2TB 6G SAS 7.2K rpm LFF (3.5-inch) SC Midline 1yr Warranty Hard Drive

HP 1TB 6G SAS 7.2K rpm LFF (3.5-inch) SC Midline 1yr Warranty Hard Drive

NOTE:

Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/12244_div/12244_div.html

(Worldwide)

HP 6G SATA Hard Drives

6G SATA Hot Plug with SmartDrive SFF (2.5-inch) Midline (MDL) Drives

HP 1TB 6G SATA 7.2K rpm SFF (2.5-inch) SC Midline 1yr Warranty Hard Drive

HP 500GB 6G SATA 7.2K rpm SFF (2.5-inch) SC Midline 1yr Warranty Hard Drive

6G SATA Hot Plug with SmartDrive LFF (3.5-inch) Midline (MDL) Drives

HP 4TB 6G SATA 7.2k rpm LFF (3.5-inch) SC Midline 1yr Warranty Hard Drive

HP 3TB 6G SATA 7.2K rpm LFF (3.5-inch) SC Midline 1yr Warranty Hard Drive

HP 2TB 6G SATA 7.2K rpm LFF (3.5-inch) SC Midline 1yr Warranty Hard Drive

HP 1TB 6G SATA 7.2K rpm LFF (3.5-inch) SC Midline 1yr Warranty Hard Drive

HP 500GB 6G SATA 7.2K rpm LFF (3.5-inch) SC Midline 1yr Warranty Hard Drive

6G SATA Non-hot Plug LFF (3.5-inch) Midline (MDL) Drives

HP 3TB 6G SATA 7.2K rpm LFF (3.5-inch) Non-hot plug Midline 1yr Warranty Hard Drive

HP 2TB 6G SATA 7.2K rpm LFF (3.5-inch) Non-hot plug Midline 1yr Warranty Hard Drive

HP 1TB 6G SATA 7.2K rpm LFF (3.5-inch) Non-hot plug Midline 1yr Warranty Hard Drive

HP 500GB 6G SATA 7.2K rpm LFF (3.5-inch) Non-hot plug Midline 1yr Warranty Hard

Drive

NOTE:

Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/13021_div/13021_div.html

(Worldwide)

697574-B21

652589-B21

652583-B21

652572-B21

652564-B21

652611-B21

652605-B21

652749-B21

652745-B21

652620-B21

652615-B21

695510-B21

652766-B21

652757-B21

652753-B21

655710-B21

655708-B21

693687-B21

628061-B21

658079-B21

657750-B21

658071-B21

628065-B21

659339-B21

659337-B21

659341-B21

DA - 14341 Worldwide — Version 12 — April 18, 2014 Page 14

QuickSpecs

Related Options

HP Smart Array P822 Controller

HP Solid State Drives (SSD)

6G SATA Value Endurance Hot Plug SFF (2.5-inch) Enterprise Boot Solid State Drives

HP 120GB 6G SATA Value Endurance SFF 2.5-in SC Enterprise Boot 3yr Wty Solid State

Drive

HP 80GB 6G SATA Value Endurance SFF 2.5-in SC Enterprise Boot 3yr Wty Solid State

Drive

6G SATA Value Endurance Hot Plug LFF (3.5-inch) Enterprise Boot Solid State Drives

HP 120GB 6G SATA Value Endurance LFF 3.5-in SC Enterprise Boot 3yr Wty Solid State

Drive

HP 80GB 6G SATA Value Endurance LFF 3.5-in SC Enterprise Boot 3yr Wty Solid State

Drive

6G SATA Value Endurance Hot Plug SFF (2.5-inch) Enterprise Value Solid State Drives

HP 800GB 6G SATA Value Endurance SFF 2.5-in SC Enterprise Value 3yr Wty Solid State

Drive

HP 480GB 6G SATA Value Endurance SFF 2.5-in SC Enterprise Value 3yr Wty Solid State

Drive

HP 240GB 6G SATA Value Endurance SFF 2.5-in SC Enterprise Value 3yr Wty Solid State

Drive

6G SATA Value Endurance Hot Plug LFF (3.5-inch) Enterprise Value Solid State Drives

HP 800GB 6G SATA Value Endurance LFF 3.5-in SC Enterprise Value 3yr Wty Solid State

Drive

HP 480GB 6G SATA Value Endurance LFF 3.5-in SC Enterprise Value 3yr Wty Solid State

Drive

HP 240GB 6G SATA Value Endurance LFF 3.5-in SC Enterprise Value 3yr Wty Solid State

Drive

6G SATA ME Hot Plug SFF (2.5-inch) Enterprise Mainstream Solid State Drives

HP 800GB 6G SATA Mainstream Endurance SFF 2.5-in SC Enterprise Mainstream 3yr Wty

Solid State Drive

HP 400GB 6G SATA Mainstream Endurance SFF 2.5-in SC Enterprise Mainstream 3yr Wty

Solid State Drive

HP 200GB 6G SATA Mainstream Endurance SFF 2.5-in SC Enterprise Mainstream 3yr Wty

Solid State Drive

HP 100GB 6G SATA Mainstream Endurance SFF 2.5-in SC Enterprise Mainstream 3yr Wty

Solid State Drive

6G SATA ME Hot Plug SFF (3.5-inch) Enterprise Mainstream Solid State Drives

HP 800GB 6G SATA Mainstream Endurance LFF 3.5-in SC Enterprise Mainstream 3yr Wty

Solid State Drive

HP 400GB 6G SATA Mainstream Endurance LFF 3.5-in SC Enterprise Mainstream 3yr Wty

Solid State Drive

HP 200GB 6G SATA Mainstream Endurance LFF 3.5-in SC Enterprise Mainstream 3yr Wty

Solid State Drive

HP 100GB 6G SATA Mainstream Endurance LFF 3.5-in SC Enterprise Mainstream 3yr Wty

Solid State Drive

6G SAS ME Hot Plug SFF (2.5-inch) Enterprise Mainstream Solid State Drives

HP 800GB 6G SAS Mainstream Endurance SFF 2.5-in SC Enterprise Mainstream 3yr Wty

Solid State Drive

717965-B21

734360-B21

718171-B21

734362-B21

717973-B21

717971-B21

717969-B21

718189-B21

718183-B21

718177-B21

691868-B21

691866-B21

691864-B21

691862-B21

691860-B21

691856-B21

691854-B21

691852-B21

690829-B21

DA - 14341 Worldwide — Version 12 — April 18, 2014 Page 15

QuickSpecs

Related Options

HP Smart Array P822 Controller

HP 400GB 6G SAS Mainstream Endurance SFF 2.5-in SC Enterprise Mainstream 3yr Wty

Solid State Drive

HP 200GB 6G SAS Mainstream Endurance SFF 2.5-in SC Enterprise Mainstream 3yr Wty

Solid State Drive

6G SAS SLC Hot Plug SFF (2.5-inch) Enterprise Performance Solid State Drives

HP 400GB 6G SAS SLC SFF (2.5-inch) SC Enterprise Performance 3yr Warranty Solid

State Drive

HP 200GB 6G SAS SLC SFF (2.5-inch) SC Enterprise Performance 3yr Warranty Solid

State Drive

NOTE:

Please see the QuickSpecs for Technical Specifications and additional information: http://h18000.www1.hp.com/products/quickspecs/14038_div/14038_div.html

(Worldwide)

NOTE:

Go to the HP Hard Drive Compatibility table for complete drive compatibility information ( http://www.hp.com/products/harddiskdrives ). Using hard drives in unsupported configurations will result in voiding the warranty and could result in damage to the drive and/or loss of data.

NOTE:

The components of a storage subsystem (e.g. the drive, the HBA/controller, firmware, and the server backplane) should operate at the same data transfer rate or the system bandwidth will be negotiated down to an acceptable level for all components.

NOTE:

Hard drives have either a one year or three year warranty; refer to the specific hard drive QuickSpecs for details.

690827-B21

690825-B21

653082-B21

653078-B21

Modular Storage Array Disk Enclosures

HP D6000 Disk Enclosure

HP D6000 Dual I/O Module Disk Enclosure

NOTE:

Please see the QuickSpecs for additional information and a list of compatible hard drives: http://h18000.www1.hp.com/products/quickspecs/14419_div/14419_div.html

HP D2000 Disk Enclosures

HP D2600 Disk Enclosure

NOTE:

Supports 12 LFF drives, and SAS 6 Gb/s and SATA 3 Gb/s.

HP D2700 Disk Enclosure

NOTE:

Supports 25 SFF drives, and SAS 6 Gb/s and SATA 3 Gb/s.

NOTE:

Please see the QuickSpecs for additional information and a list of compatible hard drives: http://h18000.www1.hp.com/products/quickspecs/13404_div/13404_div.html

QQ695A

AJ940A

AJ941A

DA - 14341 Worldwide — Version 12 — April 18, 2014 Page 16

QuickSpecs

Related Options

Tape Storage

HP Smart Array P822 Controller

Tape Libraries

HP StorageWorks MSL8096 2 LTO-4 Ultrium 1760 SAS Drive Library

SAS Cables for Tape Drives and Automation

HP Mini-SAS Cable for LTO Internal Tape Drive

NOTE:

Use this cable to connect HP Ultrium 448, 920, 960, 1760 and1840 SAS internal tape drives to Mini-SAS (SFF8087) ports. This replaces the existing cable connecting the

HBA/controller to the disk backplane. This replacement cable has three channels for disks and 1 channel for the tape drive (SFF8482 port).

HP SAS Min-Min 1x-2M Cable Assembly Kit

NOTE:

Use this cable to connect HP SAS external tape devices to HP SAS controllers with external Mini-SAS (SFF8088) connectors.

HP SAS MIN-MIN 1X-4M Cable Assembly Kit

NOTE:

Use this cable to connect HP SAS external tape devices to HP SAS controllers with external Mini-SAS (SFF8088) connectors.

HP SAS MIN-MIN 3X1X-5M Cable Assembly Kit

NOTE:

This split cable connects internally to SAS Hard Drive Cage (3 channels) and externally to the tape drive (1channel) with other connector attaching to the controller.

The external cable, for the drive, requires a PCI slot to exit the server.

HP 2m External Mini-SAS to 4x1 Mini-SAS Cable

NOTE:

One cable is required for every four drives. Use this cable to connect HP MSL SAS

Tape Libraries to Mini-SAS (SFF8088) ports.

HP 4m External Mini-SAS to 4x1 Mini-SAS Cable

NOTE:

One cable is required for every four drives. Use this cable to connect HP MSL SAS

Tape Libraries to Mini-SAS (SFF8088) ports.

AH382A

AP746A

AE470A

AE465A

AG452A

AN975A

AN976A

Mini SAS to Mini SAS

Cables

HP Mini SAS Straight to Left 33in Cable Assembly

HP Mini SAS Straight to Straight 37in Cable Assembly

HP Double Mini SAS Y 36in Cable Assembly

662899-B21

662897-B21

662901-B21

DA - 14341 Worldwide — Version 12 — April 18, 2014 Page 17

QuickSpecs

Technical Specifications

HP Smart Array P822 Controller

Dimensions

(excluding bracket)

PCI Card Size

PCI Label

PCI Link Rate

6.6 in x 4.4 in x 0.7 in (16.8 cm x 11.1 cm x 1.8 cm)

Full-height, 1/2 length, PCIe stand-up board

PCIe3 x8 (i.e., x8 mechanical, up to x8 electrical) x8 8 GT/s PCI-e (8 GB/s maximum bandwidth in each direction)

SAS/SATA Connectivity

2 Mini SAS 4i connectors

4 Mini SAS 4x connectors

SAS/SATA Link Rate

SAS protocol: 6 Gb/s, 3 Gb/s, or 1.5 Gb/s

SATA protocol: 6 Gb/s or 3 Gb/s

SAS/SATA Performance

Controller supports a maximum of 14.4GB/s maximum bandwidth in each direction (allocated across all the connectors)

RAID Cache

2 GB capacity (not all of which is available for user data)

64-bit data width with 8-bit error correcting code (ECC)

Flash-backed on power loss

Tether to capacitor pack

Removable

RAID Cache Bus Speed

Software upgradeable

Firmware

Maximum Drive Count

DDR3-1600

Yes

227 drives

System Memory

Addressing

64-bit, supporting servers memory space greater than 4 GiB

RAID Support

RAID 0 (Striping)

RAID 1 (Mirroring)

RAID 1+0 (Striping & Mirroring)

RAID 5 (Distributed Data Guarding)

RAID 6 (Advanced Data Guarding)

RAID 50

RAID 60

RAID 1 ADM (Advanced Data Mirroring)

Upgradeable Firmware

Flashable ROM with redundant firmware images

Environment-friendly

Products and Approach

End-of-life Management and Recycling

Hewlett-Packard offers end-of-life HP product return, trade-in, and recycling programs in many geographic areas. For trade-in information, please go to: http://www.hp.com/go/green . To recycle your product, please go to: http://www.hp.com/go/green or contact your nearest HP sales office.

Products returned to HP will be recycled, recovered or disposed of in a responsible manner.

The EU WEEE directive (2002/95/EC) requires manufacturers to provide treatment information for each product type for use by treatment facilities.

This information (product disassembly instructions) is posted on the Hewlett

Packard web site at: http://www.hp.com/go/green . These instructions may be used by recyclers and other WEEE treatment facilities as well as HP OEM customers who integrate and re-sell HP equipment.

DA - 14341 Worldwide — Version 12 — April 18, 2014 Page 18

QuickSpecs

Technical Specifications

© Copyright 2014 Hewlett-Packard Development Company, L.P.

HP Smart Array P822 Controller

The information contained herein is subject to change without notice. Microsoft and Windows are registered trademarks or trademarks of Microsoft Corporation in the U.S. and/or other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.

For hard drives, 1GB = 1 billion bytes. Actual formatted capacity is less.

DA - 14341 Worldwide — Version 12 — April 18, 2014 Page 19