advertisement
Split System
Cooling
Product Data
XL18i
4TTX8024, 036, 048 & 060
2, 3, 4 & 5 Tons
PUB. NO. 22-1885-01
Features and
Benefits
•
CLIMATUFF™ 2-stage scroll compressor
•
Efficiency up to
18.0 SEER
•
All Aluminum SPINE FIN™ coil
•
WEATHERGUARD™ II top shields unit
•
DURATUFF™ weather proof and rust proof base
•
COMFORT ”R”™ mode approved for better comfort indoors
•
QUICK-SESS™ cabinet, service access and refrigerant connections with full coil protection
•
WEATHERGUARD™ fasteners
•
Glossy corrosion resistant finish tarpaulin gray cabinet with anthracite gray top
•
Internal compressor high/low pressure & temperature protection
•
Liquid line filter/drier
•
Low sound with advanced variable speed fan motor
•
Service valve cover
•
R-410A refrigerant
•
From 70 to 100% capacity modulation
•
100% run test in the factory
•
Low ambient cooling to 55
°
as shipped
•
Extended warranties available
© 2013 Trane 2 22-1885-01
Contents
Features and Benefits 2
General Data
Product Specifications
A-weighted Sound Power Level [dB(A)]
Accessory Description and Usage
AHRI Standard Capacity Rating Conditions
Model Nomenclature
Electrical Data
Dimensions 8
Mechanical Specifications 9
6
7
4
5
5
4
4
22-1885-01 3
General
Data
Product Specifications
Model No. 1
4TTX8024A1000A 4TTX8036A1000A 4TTX8048A1000A 4TTX8060A1000A
Electrical Data V/Ph/Hz
2
Min Cir Ampacity 18 24 28 41
Max Fuse Size (Amps) 20 35 45 60
Compressor CLIMATUFF
®
- SCROLL
No. Used - No. Stages
RL AMPS - LR AMPS
1-2
13 - 52
Outdoor Fan FL Amps
HP
Fan Dia (inches)
CLIMATUFF
®
- SCROLL
1-2
17 - 82
CLIMATUFF
®
- SCROLL
1-2
21.2 - 104
CLIMATUFF
®
- SCROLL
1-2
32.1 - 152.9
0.74 0.74 1.00 1.30
1/8 1/8 1/5 1/3
27.6 27.6 27.6 27.6
Coil
Refrigerant
Spine Fin™ Spine Fin™ Spine Fin™ Spine Fin™
R-410A 9/13-LB/OZ 9/13-LB/OZ 12/9-LB/OZ 12/9-LB/OZ
Line Size - (in.) O.D. Gas
3
Line Size - (in.) O.D. Liquid 3
Dimensions H x W x D (Crated) 53.4 x 35.1 x 38.7
Weight - Shipping
Weight - Net
309
261
57.4 x 35.1 x 38.7
316
266
57.4 x 35.1 x 38.7
328
291
57.4 x 35.1 x 38.7
332
295
Components
Sound
Compressor Sump Heat NO NO NO NO
Optional Accessories: 4
Rubber Isolator Kit
Snow Leg - Base & Cap 4" High BAYLEGS002
Snow Leg - 4" Extension
Hard Start Kit Scroll
Crankcase Heater Kit
Extreme Condition Mounting Kit
BAYISLT101
BAYLEGS003
BAYKSKT260
BAYCCHT302
BAYECMT023
BAYISLT101
BAYLEGS002
BAYLEGS003
BAYKSKT260
BAYCCHT302
BAYECMT004
BAYISLT101
BAYLEGS002
BAYLEGS003
BAYKSKT263
BAYCCHT301
BAYECMT004
BAYISLT101
BAYLEGS002
BAYLEGS003
BAYKSKT263
BAYCCHT301
BAYECMT004
Vertical Discharge Air Kit Base 4 BAYVDTA003
Auto Charge Solenoid Kit BAYCAKT001
Refrigerant Lineset
5
BAYVDTA004
BAYCAKT001
BAYVDTA004
BAYCAKT001
BAYVDTA004
BAYCAKT001
TAYREFLN9* TAYREFLN7* TAYREFLN3* TAYREFLN4*
1 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240.
2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.
3 Standard line lengths - 60'. Standard lift - 25' Suction and Liquid line.
For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0
4 For accessory description and usage, see page 5.
5 * = 15, 20, 25, 30, 40 and 50 foot lineset available.
† . ( † denotes latest revision)
Model
A-Weighted Sound
Power Level [dB(A)]
63 Hz
4TTX8024A1
4TTX8036A1
4TTX8048A1
72
72
73
70
64
70
4TTX8060A1 74 68
Note: Rated in accordance with AHRI Standard 270-2008
Sound Power Level
Full Octave Sound Power [dB]
125 Hz
69
67
67
70
250 Hz
63
65
68
66
500 Hz
66
64
66
69
1000 Hz 2000 Hz 4000 Hz 8000 Hz
60
60
63
66
56
56
56
57
53
54
53
57
48
50
49
53
4 22-1885-01
General
Data
Accessory Description and Usage
Rubber Isolators — 5 rubber donuts to isolate condensing unit from mounting frame or pad. Use on any application where sound transmission needs to be minimized.
Extreme Conditions Mounting Kit — Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial rooftops, etc.
Low Ambient Cooling — For low ambient cooling below 55° see Application Guide APP-APG013-EN.
AHRI Standard Capacity Rating Conditions
AHRI STANDARD 210/240 RATING CONDITIONS —
(A) Cooling 80°F DB, 67°F WB air entering indoor coil,
95°F DB air entering outdoor coil.
(B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil.
(C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil.
(D) Rated indoor airflow for heating is the same as for cooling.
AHRI STANDARD 270 RATING CONDITIONS — (Noise rating numbers are determined with the unit in cooling operation.) Standard Noise Rating number is at 95°F outdoor air.
22-1885-01 5
Model
Nomenclature
Outdoor Units
Refrigerant Type
4 = R-410A
TRANE
Product Type
W = Split Heat Pump
T = Split Cooling
Product Family
Z = Leadership – Two Stage
X = Leadership
R = Replacement/Retail
M or B = Basic
A = Light Commercial
Family SEER
3 = 13 6 = 16 0 = 20
4 = 14 8 = 18
5 = 15 9 = 19
Split System Connections 1-6 Tons
0 = Brazed
Nominal Capacity in 000s of BTUs
Major Design Modifications
Power Supply
1 = 200-230/1/60 or 208-230/1/60
3 = 200-230/3/60
4 = 460/3/60
Secondary Function
Minor Design Modifications
Unit Parts Identifier
4 T T X 8 0 3 6 A 1 0 0 0 A A
Gas Furnaces
T U D 1 B 0 8 0 A 9 H 3 1 A A
Furnace Configuration
TU = Upflow/Horizontal
TD = Downflow/Horizontal
Type
E = 80% Induced Draft Standard
D = 80% Induced Draft Premium
C = 90% Condensing Standard
X = 90% Condensing Premium
H = 95% Condensing Premium
Number of Heating Stages
1 = Single Stage
2 = Two Stage
M = Modulating
Cabinet Width
A = 14.5" Cabinet Width
B = 17.5" Cabinet Width
C = 21.0" Cabinet Width
D = 24.5" Cabinet Width
Heating Input in 1000’s (BTUH)
080 = 80,000 BTUH
Major Design Change
Voltage
9 = 115 Volts / 60 Hertz / Natural Gas
A = 115 Volts / 50 Hertz / Natural Gas
C = 115 Volts / Natural Gas with Communicating System Control
F = 115 Volts / Natural Gas with Integrated Electronic Filter
D = 115 Volts / Natural Gas with Communicating System Control and
Integrated Electronic Filter
Air Capacity for Cooling
Standard PSC Variable Speed High Efficiency
24 = 2 Tons
36 = 3 Tons
42 = 3.5 Tons V5 = 5 Tons
45 = 4 Tons
48 = 4 Tons
54 = 5 Tons
60 = 5 Tons
72 = 6 Tons
V3 = 3 Tons
V4 = 4 Tons
H3 = 3 Tons
H4 = 4 Tons
H5 = 5 Tons
Draft Inducer Speeds
1 = Single Speed
2 = Two Speed
V = Variable Speed
Minor Design Change
Service Digit - Not Orderable
Air Handler
G A M 5 A 0 B 3 6 M 3 1 S A A
Brand
T = Better
G = Good
Product Type
A = Air Handler
Convertability
M = Multi-poise 4-way
F = Upflow Front Return, 3-way
T = 3-way
Product Tier
2 = Good, Entry Level Feature Set
4 = Better, Retail Replacement Mid Effy.
5 = Better, Entry Level High Effy., Multi-Speed
7 = Best, Retail Replacement High Effy.,
Variable-Speed
8 = Best, Retail Ultimate High Effy.,
Variable-Speed
Major Design Change
No Descriptor
0 = Air Handler / Coil
Size (Footprint)
A = 17.5 x 21.5
B = 21.0 x 21.5
C = 23.5 x 21.5
Cooling Size: Air Handler or Coil
0-9 = AH Coil - 1000 BTU’s (18, 24, 30, 36, 42, 48, 60)
Airflow Type & Capability
S = Low Effy PSC, 1-5 - nom. Tonnage (cfm/ton)
M = Mid Effy Multi-Speed, 1-5 - nom. Tonnage (cfm/ton)
H = High Effy Multi-Speed, 1-5 - nom. Tonnage (cfm/ton)
V = High Effy Variable, 1-5 - nom. Tonnage (cfm/ton)
Power Supply
1 = 208-230/1/60
System Control Type
S = Standard - 24 VAC
C = CLII 13.8 VDC
Minor Design Change
Unit Parts Identifier
Heat Pump/
Cooling Coils
4 T X C B 0 3 6 A C 3 H C A A
Refrigerant Type
4 = R-410A
Series
T = Premium (Heat Pump or Convertible Coil)
C = Standard (Cooling Only)
Coil Design
X = Direct Expansion Evaporator Coil
Coil Feature
C = Cased A Coil
A = Uncased A Coil
F = Cased Horizontal Flat Coil
Coil Width (Cased/Uncased)
A = 14.5" /13.3"
B = 17.5" / 16.3"
C = 21.0" / 19.8"
D = 24.5" / 23.3"
H = 10.5"
Refrigerant Line Coupling
0 = Brazed
Nominal Capacity in 1000's (BTUH)
Major Design Change
Efficiency
C = Standard
S = Hi Efficiency (derived from 10 SEER products)
Refrigerant Control
3 = TXV - Non-Bleed
Coil Circuitry
H = Heat Pump
C = Cooling
Airflow Configuration
A = Upflow Only
U = Upflow / Downflow
H = Horizontal Only
C = Convertible - Upflow, Downflow, Left or Right Airflow
Minor Design Change
Service Digit - Not Orderable
6 22-1885-01
Electrical
Data
Schematic Diagrams
(SEE LEGEND)
4TTX8024A, 036A
22-1885-01 7
Printed from D157614P01
Electrical
Data
Schematic Diagrams
(SEE LEGEND)
4TTX8048A, 060A
Printed from D156975P03
8 22-1885-01
Electrical
Data
Schematic Diagrams
LEGEND
22-1885-01 9
Dimensions
4TTX8 Outline Drawing
Note: All dimensions are in MM (Inches).
MODELS
4TTX8024A
4TTX8036A
4TTX8048A
4TTX8060A
BASE
4
4
4
4
A B C D E
1267 (49-7/8) 946 (37-1/4) 870 (34-1/4) 5/8 3/8
1369 (53-7/8) 946 (37-1/4) 870 (34-1/4) 3/4 3/8
1369 (53-7/8) 946 (37-1/4) 870 (34-1/4) 7/8 3/8
1369 (53-7/8) 946 (37-1/4) 870 (34-1/4) 1-1/8 3/8
F
152 (6)
152 (6)
152 (6)
152 (6)
G H J
98 (3-7/8) 219 (8-5/8) 86 (3-3/8)
98 (3-7/8) 219 (8-5/8) 86 (3-3/8)
98 (3-7/8) 219 (8-5/8) 86 (3-3/8)
98 (3-7/8) 219 (8-5/8) 86 (3-3/8)
K
730 (28-3/4)
730 (28-3/4)
730 (28-3/4)
730 (28-3/4)
From Dwg. D152635 Rev. 16
10 22-1885-01
Mechanical
Specifications
General
The 4TTX8 is fully charged from the factory for matched indoor section and up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are
AHRI certified. The unit shall be certified to UL 1995. Exterior is designed for outdoor application.
Casing
Unit casing is constructed of heavy gauge, G60 galvanized steel and painted with a weather-resistant powder paint on all louvers and panels. Corrosion and weatherproof CMBP-G30
DuraTuff™ base.
Refrigerant Controls
Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard.
Compressor
The Climatuff ® 2-stage compressor features internal over temperature and pressure protection and hermetic motor.
Other features include centrifugal oil pump and modular plugs for electrical connections.
Condenser Coil
The outdoor coil provides low airflow resistance and efficient heat transfer.
The coil is protected on all four sides by louvered panels.
Low Ambient Cooling
As manufactured, this unit has a cooling capability to 55°F. For low ambient cooling below 55° see Application Guide
APP-APG013-EN.
22-1885-01 11
Trane www.trane.com
05/13
Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.