EIP CD35 Owner's Manual

Add to my manuals
12 Pages

advertisement

EIP CD35 Owner's Manual | Manualzz

Drawing : - TPC225

Issue : - 3

Date : - 05/01/12

CD35 / CD35P

INDUSTRIAL DEHUMIDIFIER

OWNER’S MANUAL

www.eipl.co.uk

Page 1 of 12

Service Questions: Contact Ebac USA at 1-757 873 6800

Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit sylvane.com

Drawing : - TPC225

Issue : - 3

Date : - 05/01/12

INTRODUCTION

Designed for a wide range of applications, the CD35 is a rugged, compact unit which incorporates its own tank for collected moisture with an automatic shutoff once the tank is fully. Offices, shops, houses, restaurants and storerooms can be protected by this simple answer to humidity control.

The CD35 has a number of special features:

Adjustable humidistat

“Hot Gas” defrost system with solid state controller

Whisper-quiet fan

Water tank with “full” indicator lamp

All galvanized interior

Exterior epoxy powder-coated finish

Four independent heavy-duty castors

Fully enclosed coils

The fan draws the moist air through the cold evaporator coil, which cools the air below its dew point. Moisture forms on the evaporator coil and is collected in the condensate tray, which is equipped with a permanent drain. The cooled air then passes through the hot condenser coil where it is reheated using the same energy removed during the cooling phase, plus the additional heat generated by the compressor. The air is, therefore, discharged from the dehumidifier at a slightly higher temperature with a lower absolute humidity than that which entered. Continuous circulation of air through the dehumidifier gradually reduces the relative humidity within the area.

The CD35 dehumidifier is a rugged, reliable drying unit designed to operate effectively over a broad range of temperature and humidity conditions. An active hot gas defrost system, controlled by an electronic timer, guarantees positive de-icing, thereby optimizing operation at low temperatures.

The unit incorporates a welded and galvanized steel chassis and is finished in an epoxy coating for resilience to damage caused by rough handling.

The CD35 dehumidifier is fitted with an adjustable humidistat to enable you to select the level of dryness that you desire.

Page 2 of 12

Drawing : - TPC225

Issue : - 3

Date : - 05/01/12

SPECIFICATIONS

M

ODEL

: Ebac CD35 / CD35P

H

EIGHT

: 22”

P

C

C

R

R

F

OMPRESSOR

EF

.

A

OWER

AN

C

C

W

D

W

IDTH

EPTH

EIGHT

IRFLOW

S

URRENT

M

UPPLY

(

MAX

OTOR

ONTROL

EFRIGERANT

HARGE

: 13.5”

: 14”

:

CD35 – 57 lbs

CD35P – 63 lbs

: 170 CFM

: 110V/ 60Hz/ 1 ph

):

:

:

CD35 – 4 A

CD35P – 5 A

1/50 HP MagneTek

Totally Enclosed

¼ HP Heavy Duty Fully

Hermetic Tecumseh

: Adjustable Humidistat

: R-134a

: 0.17Kg

C

ONSTRUCTION

F

EATURES

:

:

18 AWG Epoxy Power

Coated galvanized steel

Hot Gas Defrost down to 33 Deg. F

"This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The refrigeration system is hermetically sealed.

The Global Warming Potential (GWP) of refrigerants used in products manufactured by Ebac

Industrial Products Ltd is as follows

R134a – 1300

R407c – 1610

For type and weight of refrigerant contained in this unit, please refer to the product data label"

Page 3 of 12

Drawing : - TPC225

Issue : - 3

Date : - 05/01/12

FEATURES

The Adjustable Humidistat: The adjustable humidistat enables you to maintain the required level of dryness within a room. The humidistat switches off the CD35 when the relative humidity falls to the level predetermined by the position of the humidistat control.

The Water Tank: When the water tank has reached its capacity, a float mechanism will activate a microswitch lever and switch off the machine. The container-full indicator will also illuminate.

Before emptying the water container, disconnect the power supply and allow the dryer to stand for five minutes. Remove the container from the rear of the unit and when emptied, replace, taking care to ensure that the float mechanism is correctly positioned. Restart unit as instructed in the following

Operation section of this manual.

UNPACKING & INSTALLATION

After removing the CD35 from its shipping container, visually check for signs of damage. If there is evidence of damage, do not operate. Call your supplier for advice. Do not discard the packing as it will be useful when transporting the machine in the future.

Wiring: Connect the power cord to a grounded single phase, 15 Amp fused, standard household wall socket.

POSITIONING

Single Room: Position the CD35 in the center of the room to be dried.

However, if a damp patch is particularly apparent, the outlet grille should be directed towards it. If the CD35 cannot be positioned centrally, a minimum space of 6” should be allowed around the dryer.

Several Rooms: To dry a number of rooms simultaneously with the most efficiency, the dryer as to be positioned between the rooms. Ensure that all doors are left ajar allowing a patch for the air to circulate to the unit. An auxiliary circulation fan would be helpful.

Page 4 of 12

Drawing : - TPC225

Issue : - 3

Date : - 05/01/12

SPECIAL FEATURES (where fitted)

CONDENSATE PUMP:

The CD-35 dehumidifier unit can be fitted, either in the factory, or as retro-fit, with a condensate pump. This condensate pump will allow the unit to run unattended, with the condensate run off to a permanent drain and can be used up to 150 feet (50 meters), below the level of a permanent condensate drainage point.

HUMIDISTAT CONTROL:

The CD-35 dehumidifier unit is fitted with a control humidistat which measures the relative humidity of the air within the room. The humidistat incorporates a pointer and scale, which can be adjusted, and set to a relative humidity level that is acceptable to maintain the required conditions within the room. The humidistat controls the on/off function of the dehumidifier. When the relative humidity of the air in the room falls below the set point of the humidistat the dehumidifier will switch off, but when the relative humidity of the air starts to rise again and passes the set point the unit will switch on. The humidistat is used for the on/off function as it is a cost effective method which ensures power is only used when needed.

TEMPERATURE CONTROLLED DEVICE:

The CD-35 dehumidifier unit is fitted with a temperature sensitive device which operates in conjunction with the defrost control. In normal operation the defrost control will come into operation every 45 minutes. This is to ensure that there will be no build up of ice at lower temperatures. At very low temperatures it is still possible for the defrost device not to clear the ice completely from the evaporator coil. To ensure that even at these very low temperatures all the ice is cleared from the coil, the temperature control device will stop the fan (preventing air movement). This will increase the temperature of the evaporator coil even higher, causing all the ice to melt from the coil during the defrost mode. Where year round conditions need to be maintained, the dehumidifier unit will have to operate across a wider range of temperatures. To ensure that the dehumidifier unit operates at its most efficient, the temperature control device will restrict the defrost operation to the times when the ambient temperature falls below 25°C.

Page 5 of 12

Drawing : - TPC225

Issue : - 3

Date : - 05/01/12

WARNING:

• Due to the high pressures within the refrigeration circuit, under no circumstances must direct heat be applied to the evaporator coil in an attempt to remove the build up of ice.

• No attempt should be made to cut open any part of the refrigeration circuit due to high pressures and gas involved.

If the unit is switched off at the mains power supply for any reason, the unit must be allowed to stand at rest for at least three minutes before restarting. Failure to do so may cause the unit to blow the fuses owing to the compressor due to there being a refrigerant imbalance.

Page 6 of 12

Drawing : - TPC225

Issue : - 3

Date : - 05/01/12

ROUTINE MAINTENANCE

WARNING:

ENSURE THAT THE POWER CORD TO THE MACHINE HAS

BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE

MAINTENACE ON ITEMS 1, 2, 3, AND 4.

To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows:

Removal of the cover is achieved by means of four screws at the sides of the unit at base level. With the cover removed all maintenance can be carried out.

1. Clean the surface of the evaporator and condenser coils by blowing the dirt out from behind the fins with compressed air. Hold the nozzle of the air hose away from the coil (approx 6”/150 mm) to avoid damaging the fins. Alternatively, vacuum clean the coils.

WARNING:

DO NOT STEAM CLEAN REFRIGERATION COILS

2. Check that the fan is firmly secured to the motor shaft and that the fan rotates freely. Using mobile DD heavy medium oil, lubricate the motor bearing with 10 drops every 6 months.

3. To check the refrigerant charge, run the unit for 15 minutes and briefly remove the cover. The evaporator coil should be evenly frost coated across its surface. At temperatures above 20°C, the coil may be covered with droplets of water rather than frost. Partial frosting accompanied by frosting of the thin capillary tubes, indicates loss of refrigerant gas or low charge.

4. Check all wiring connections.

I

F ANY OF THE PRECEDING PROBLEMS OCCUR

,

CONTACT THE

E

BAC

S

ERVICE

C

ENTER PRIOR TO CONTINUED OPERATION OF THE UNIT TO

PREVENT PERMANENT DAMAGE

.

Page 7 of 12

Drawing : - TPC225

Issue : - 3

Date : - 05/01/12

REPAIRS

1. Should an electrical component fail, consult the Factory Service

Center to obtain the proper replacement part.

2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory

Service Center prior to initiating this action.

Any competent refrigeration technician will be able to service the equipment. The following procedure must be used: a. The source of the leak must be determined and corrected. b. The machine should be thoroughly evacuated before recharging. c. The unit must be recharged with refrigerant measured accurately by weight. d. For evacuation and recharging of the machine, use the crimped and brazed charging stub attached to the side of the refrigerant compressor.

The charging stub should be crimped and rebrazed after servicing. N

EVER

allow permanent service valves to be fitted to any part of the circuit. Service valves may leak causing further loss of refrigerant gas.

3. The refrigerant compressor fitted to the dehumidifier is a durable unit that should give many years of service. Compressor failure can result from the machine losing its refrigerant gas. The compressor can be replaced by a competent refrigeration technician.

Failure of the compressor can be confirmed by the following procedure: a. Establish that power is present at the compressor terminals using a voltmeter. b. With the power disconnected, check the continuity of the internal winding by using meter across the compressor terminals. An open circuit indicates that the compressor should be replaced. c. Check that the compressor is not grounded by establishing that a circuit does not exist between the compressor terminals and the shell of the compressor.

Page 8 of 12

Drawing : - TPC225

Issue : - 3

Date : - 05/01/12

S

YMPTOM extraction when required

Unit vibrates excessively

Unit inoperative

Little or no airflow

Little or no water

Little or no defrost

TROUBLESHOOTING

C

AUSE

1. No power to unit

1. Loose fan on shaft

2. Fan motor burnt out

3. Dirty refrigeration coils

4. Loose electrical wiring

5. Fuse blown or circuit breaker tripped

1. Insufficient air flow

2. Compressor fault

3. Loss of refrigerant gas

4. Blocked filter dryer

1. Loose compressor

2. Damaged fan

Water flooding inside the machine

1. Drain pipe blocked/frozen

2. Drain pipe too high

3. Crimped or blocked tubing

4. Defective Pump

Hissing noise from the machine

1. Faulty timer

2. Faulty by-pass valve

1. Machine defrosting – normal operation

R

EMEDY

1. Check the power from power supply panel

1. Tighten fan

2. Replace the fan motor

3. See Routine Maintenance

Section

4. Check the wiring diagram to find fault and repair

5. Replace the fuse or reset the circuit breaker

1. Check all of the above

2. Contact the Factory

Service Center

3. Contact the Factory

Service Center

4. Contact the Factory

Service Center

1. Contact the Factory

Service Center

2. Contact the Factory

Service Center

1. Tighten the nuts on the compressor mounts

2. Replace fan

1. Clear the obstruction

2. Ensure that no section of the drain hose is above the level of the water outlet

3. Straighten, clear, or replace tubing

4. Replace pump

N/A

Page 9 of 12

CD35

SPARE PARTS LIST

Drawing : - TPC225

Issue : - 3

Date : - 05/01/12

3050216

1617990

2141095

3021518

3021543

3021544

3022147

3030421

3035773

2018641

1600500

3030275

2013837

Part Number Description

1018611 EVAP COIL ASSY

1137907

2013865

2013866

WATER CONTAINER

MICROSWITCH SUPPORT

MICROSWITCH LEVER

2017707

2131107

2131147

3014272

3020811

3020937

3033033

3035145

3035346

3036636

3040181

HUMIDEX 7 KNOB

HUMIDEX DRAIN TRAY

CONDENSER COIL

CAPILLIARY TUBE .031 Already Cut

BY-PASS VALVE

FILTER DRYER

MICROSWITCH

HUMIDISTAT

PANEL MOUNTED TERMINAL BLOCK

RED LAMP ASSY

FAN BLADE

CASTOR

PCB

MAINS POWER CABLE

COMPRESSOR BOX COVER

OHP

RELAY

COMPRESSOR

SOLENOID COIL

MOTOR

EVAPORATOR COIL

PCB (Pre-95 Model)

110V RELAY (Pre-95 Model)

DRAIN TRAY

Spare parts available online www.EIPLDIRECT.com

Page 10 of 12

Drawing : - TPC225

Issue : - 3

Date : - 05/01/12

LIMITED WARRANTY

Our products carry a one-year unconditional warranty against any defects in workmanship or material. This warranty will cover all parts and labour required to repair your Ebac product. This warranty is invalid if the unit has been abused, damaged, whether intentional or accidental, or if any modifications have been made to the unit.

THE FOREGOING WARRANTY IS EXCLUSIVE AND IS ISSUED IN LIEU OF

ALL OTHER WARRANTIES (WHETHER WRITTEN, ORAL, OR IMPLIED)

INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. EBAC

INDUSTRIAL PRODUCTS, INC. DISCLAIMS ANY LIABILITY FOR

CONSEQUENTIAL DAMAGES, LOST PROFITS, OR INCIDENTAL

DAMAGES FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY

WITH RESPECT TO THE FOREGOING DESCRIBED MERCHANDISE.

For Your Records: Model:____________________

S/N:______________________

Date Received:______________

SAVE THIS SECTION FOR YOUR RECORDS

CLIP AND RETURN THIS CARD

PLEASE NOTE

To ensure that your

Ebac Dehumidifier is accorded the full coverage provided by this warranty, please complete and mail this card at your earliest convenience.

Thank You

WARRANTY REGISTRATION

DATE

MODEL ___________ S/N ________________ RECEIVED ________________

OWNER __________________________________________________________

ADDRESS ________________________________________________________

CITY __________________________ STATE ________ ZIP _______________

COMMENTS ______________________________________________________

_________________________________________________________________

Ebac Industrial Products.

700 Thimble Shoals Boulevard, Suite 109, Newport News, Virginia. 23606-2575

Page 11 of 12

Drawing : - TPC225

Issue : - 3

Date : - 05/01/12

UK Head Office

Ebac Industrial Products Ltd

St Helens Trading Estate

Bishop Auckland

County Durham

DL14 9AD

Tel: +44 (0) 1388 664400

Fax: +44 (0) 1388 662590 www.eipl.co.uk

[email protected]

American Sales Office

Ebac Industrial Products Inc

700 Thimble Shoals Blvd.

Suite 109, Newport News

Virginia, 23606-2575

USA

Tel: +01 757 873 6800

Fax: +01 757 873 3632 www.ebacusa.com

[email protected]

German Sales Office

Ebac Industrial Products Ltd

Miraustra 64 – 66

13509

Berlin

Germany

Tel: +49 3043 557241

Fax: +49 3043 557240 www.eip-ltd.de

[email protected]

Page 12 of 12

Service Questions: Contact Ebac USA at 1-757 873 6800

Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit sylvane.com

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement