Sinumerik – 810T NCnet 7.0 settings Set these parameters on the machine 5010 5011 5012 5013 5016 = = = = = 0 11110101 0 11110101 xx10xxxx (Where x = 0 or 1) RTS line =1 Parameters for the various baud rates For baud rates other than 2400 set as follows: Baud rate 150 300 600 1200 2400 4800 9600 Parameter 11110001 11110010 11110011 11110100 11110101 11110110 11110111 To set the controller in the Drip-feed mode Drip feed is not available on this controller. Set these parameters on the PC Machine details Machine name Control system Machine ID Communication Channel Port Number Folder for PC to Machine transfer Folder for Machine to PC transfer Baud rate Data bits Parity Stop bits Handshake MCH-1 Sinumerik 01 Serial Port Any free COM port) Transmit directory Receive directory 2400 7 Even 2 Hardware General settings Ignore this. Leave all data as it is. Page 1 of 3 Transmit settings Wait period at start of transmission Wait period after transmitting program Size of transmit packet Delay period after each packet Wait for XON before transmitting program Transmit comments? Comment start character Comment end character Translation mode for CR Translation mode for LF Acknowledgement and error (Mode of transmission) ACK/ERR Message start text ACK/ERR Message start text Filter Null Character 10.00 5.0 0 0 No Yes ( ) Transmit as CR Transmit as LF Transmit descriptive message % MPF 1234 M30 Yes NC Program settings Program start string Program end string Characters to transmit at start Characters to transmit at start Number of Characters Number of Characters Receive settings Wait period before receiving program Wait period after receiving program Transmit XON before transmitting program Auto compare and save Acknowledgements and errors Translation mode for CR Translation mode for LF Ignore control characters other than CR-LF Save Program between Start Characters and End Characters Start Program reception after these characters are received End Program reception after these characters are received 45.0 5.0 No Yes Transmit descriptive messages Ignore Save as CRLF Yes No To set the PC in the Drip-feed mode Drip feed is not available on this controller. Page 2 of 3 Cable connections If the PC has 9 pin connector Null modem PC 9 pin Full Handshake CNC 25 pin 1 2 3 4 5 6 7 8 8 2 3 20 7 6 4 5 PC 9 pin CNC 25 pin 1 2 3 4 5 6 7 8 8 2 3 6 7 20 5 4 If the PC has 25 pin connector Null modem PC 25 pin 8 2 3 20 7 6 4 5 CNC 25 pin 8 3 2 20 7 6 4 5 Full Handshake PC 25 pin 8 2 3 20 7 6 4 5 CNC 25 pin 8 3 2 6 7 20 5 4 Page 3 of 3 ">
/
Download
Bare en venlig påmindelse. Du kan se dokumentet lige her. Men vigtigst af alt har vores AI allerede læst det. Den kan forklare komplekse ting i enkle vendinger, besvare dine spørgsmål på ethvert sprog og hjælpe dig med hurtigt at navigere selv de længste eller mest komplicerede dokumenter.
Annonce