LG Panels User Manual
Below you will find brief information for eZ-Net Manager. Monitor Ethernet and Serial connections, compatible with Windows XP and Vista. Extends serial distance using network, and single/group WAN control. With unlimited monitor connections, auto searching, self diagnosis and enabling to schedule the monitor power and input operations.
Advertisement
Advertisement
eZ-Net Manager About eZ-Net Manager eZ-Net Manager allows you to control one or more monitors more easily via Serial and Network. If eZ-Net Manager is installed on your PC, you can control various operations with a few clicks of the mouse. Also, eZ-Net Manager provides self-diagnosis of monitors and convenient upgrades for easier management. Before Use Please read the below carefully before using the eZ-Net Manager Ethernet Controller MCU + Ethernet IEEE 802.3, 10Base- T Flash 60Kbytes, Tx/Rx buffer 8Kbytes eZ-Net Manager Features LAN + Serial Management Program Compatible with Windows XP Professional and Windows Vista 32-bit Edition. Network + Serial Management Program - All-in-one Program - Extends serial distance when using Network. Single/Group WAN Control - Controls both the LAN and WAN networks. - Supports unlimited MONITOR connections. Monitor Auto Searching - Automatically searches a monitor in a same network(Sub network). Self Diagnosis - Real-time monitoring function for the lamp, fan and temperature. Scheduling - Enables to schedule the monitor power and input operations. Easy Tile Mode - Convenient GUI for the Tile Mode settings. F/W Upgrade via Network - Enables to upgrade Ethernet and the monitor F/W via Network. Instant Messaging - Enables to send the message to the monitor. A1 Installation Procedure 1) Monitor Ethernet Environment Establishment Case 1) Using a ethernet cable, connect PC to Monitor directly. Case 2) Using a router(Switch), install via LAN (Local Area Network). Case 3) Using the Internet, install via WAN (Wide Area Network). 2) IP Setup Via Monitor OSD Step 1) Select LAN under [Option] - [Network Setup] - [Network Select]. Step 2) Select DHCP or Manual. Step 3) If Manual: IP settings Step 4) Run Execute to receive an IP address. Step 5) Check the IP address under [Information] - [IP Address]. Network Setup Network Select DHCP Manual ✔ LAN RS232C MENU Manual IP Address Subnet Mask Default Gateway Primary DNS Secondary DNS Execute 192.168.000.003 255.255.255.000 192.168.000.001 169.254.001.001 169.254.001.001 MENU A2 3) eZ-Net Manager Program Installation Step 1) On the main screen of the enclosed CD-ROM, select 'eZ-Net Manager & Guide' ➞ ' eZ-Net Manager', then the installation screen will be automatically displayed. Step 2) eZ-Net Manager Setup will start on the screen. Click 'Next' Step 3) Select a destination folder and click Install. Step 4) eZ-Net Manager program will be installed. Step 5) When installation is completed, the eZ- Net Manager execution icon will be created on screen * To remove the program, execute Uninstall.exe in the destination folder or in Add/Remove Programs, and press the Uninstall button. A3 Login When you start the program, the Login screen is displayed as shown below. If you are starting the program for the first time, the default ID and Password are set as shown below. ID: Administrator Password: 0000 * If you lose your ID or password, uninstall the program and install it again. To change ID and Password, Step 1) Select Security in the toolbar. Step 2) Enter the current ID and Password into Current Setting, and select Set. If the ID and Password are invalid, the warning window appears. Step 3) When the New Setting window is activated, enter a new ID and Password, and click OK. A4 4) The Initial Screen of Management S/W Program 1 3 2 5 4 6 7 1 Tool Bar Contains Search, Settings for network connections, and Help 2 Monitor Register Window Displays searched Monitors and allows creating Monitor groups. 3 Control Tap Displays Monitor control functions. 4 Display Displays the information of a selected Monitor . 5 Status Displays the current status of a selected Monitor . 6 IP Setup Displays and allows changing a selected Monitor 's IP configuration. 7 Diagnosis Displays the real-time status of a selected Monitor . NOTE The [Upgrade] tab is used only for service. A5 Function Description Searches and registers a connected Monitor (Only Ethernet). Enables to select and set up network connections: Ethernet or Serial Enables to manually connect to a selected Monitor (Only Ethernet). Enables to refresh the information on a selected tab. The instant messaging function for the selected monitor Changes ID and Password for login. Displays the program information. Model Name : The model name of a current Monitor Serial Number : The serial number of a current Monitor Monitor SW Version : The monitor software version of a current Monitor LAN SW Version : The Ethernet software version of a current Monitor FAN, LAMP Displays a current Monitor 's fan and lamp status: (normal : OK, anomalous : NG.) Temperature (inside) Displays a current Monitor 's inner temperature. Displays a current Monitor 's overall status: Power (On/Off), Input, Signal, Screen and Volume Mutes, Picture Mode, and Aspect. IP Configuration Method Displays a current Monitor 's IP configuration (DHCP/Static). IP Information Displays a current Monitor 's IP information including MAC Address. A6 Communication Settings Provide an all-in-one program to control both serial port and network connections and improve customer convenience. Step 1) Select Setting on the toolbar; - Enables to select Network or Serial. - The default value is Network. - If Network is desired, just press OK to exit the menu. The leftward information window displays a selected network connection: Network or Serial. Displays operation progress. Step 2) If Serial Port is desired, select Serial and set up the details. 1 Port 2 1 3 2 3 4 4 5 6 5 6 A7 Select a port: COM1 ~ COM9. Default Value: COM1 Baudrate Select a connection speed: 2400 ~ 115200. Default Value: 9600 Data Select a data value: Data5 ~ Data8. Default Value: Data8 Parity Select a parity check: even, odd, none. Default Value: none Stop Select a stop bit: 0 ~ 1. Default Value: 1 Flow Control Select a flow control: Xon/Xoff, hardware, or none. Default Value: none When Communication Setting is changed (Serial <-> Network), You need to exit and restart the program. Click Yes in the popup message to exit the program. If you restart the program, the initial screen for the selected Setting is displayed. When you select Serial, the IDs of monitors supported by default are displayed in the registration window on the left side of the initial screen. You can select the ID of a monitor you want and control it. You can control it by selecting the same MNT number as the Set ID value of the monitor you selected. For MNT0, the Set ID value is 0, and you can control all monitors regardless of monitor Set IDs. However Ack Data cannot be received. A8 MONITOR Search(Only Network) Step 1) Press Search on the toolbar, and then enter an IP address. If an Monitor connection to a PC has been established, selecting SubNet (Broadcast) automatically finds the Monitor without entering the IP address. Step 2) If a desired Monitor has been successfully found, the Monitor information is displayed in the search window. If the network connection is normal, it turns blue as shown in the image. If the network is disconnected, it turns red. Also, it turns yellow if there are any errors in the fan, panel or temperature. * If the monitor does not have valid network information, Direct IP search is not available. A9 Step 3) Selecting the Monitor of a registered IP address loads the Monitor information. Step 4) Searching an inexistent or disconnected Monitor results in failure. A10 Group Settings Step 1) Select Group, right-click and select Make Group. Step 2) Enter a group name and click Set. Step 3) Right-click on a monitor in Single to add to a group and click Add to Group. Drag & Drop Interface: Drag & drop a monitor to add it to the group you want. Step 4) Select a group to add the monitor to. A11 Delete Group To delete a group or delete a monitor from a group, or if you do not want to control a specific monitor in Single, you can delete the monitor easily. Case 1) To delete a group (e.g.: McDonald) Case 2) To delete a monitor from a group (e.g.: 192.168.0.4 in McDonald) Case 3) To delete a monitor from Single If you delete a monitor from Single and it has been added to a group as well, it is also deleted from the group. A12 Display Controls Case 1) For a single Monitor, select a Monitor under the Network Communication window, and then adjust the display settings under a desired tab. Each time a new tab is selected, the main window refreshes, displaying updated information of each function. Case 2) For a group Monitor, select a group and adjust the display settings. As a group contains a multiple Monitor entries, the main window does not refresh or load the most updated information; the displayed information may be different from the current status of a selected group. A13 Selecting the Control tab and adjusting the details instantly updates the display settings. The following options are provided under the Control tab. Toggle Button Types Drop-down Combo Box Types Slide Bar Types Button Types Scheduling Step 1) If an is not set up with a clock, the Schedule tab displays as shown in the example picture; the scheduling function is disabled. A14 Step 2) Set up the clock to the current time, and then press Set. Case 1) To turn on and off at same times everyday, set up the On Time, Off Time, and Input settings. If On is selected for the Every option, every individual day values--from Mon to Sun--automatically set to the same as the everyday settings. Case 2) To set up different on and off times per day, set up each day's OnTime, OffTime, and Input settings individually. On the contrary, if On is selected for a day, the Every option automatically changes to Off. The basic operations are identical to the monitor. A15 Instant Messaging Step 1) Click the Message button in the Tool Bar to open the Message Setting dialog window. The Message Setting dialog window will not open unless you select a monitor and a group. Step 2) Set Message Align and Message Color in the Message Setting dialog window. Step 3) Enter a message in Message Send and click the Send button. * Enter text here. Up to 80 characters are supported. Bottom/Center is the default value for Message Align, and White is the default value for Message Color. * Only English characters and numbers are available. * Clicking the Send button will send the message you entered, whilst clicking the Clear button will delete it. A16 Tile Mode(1) Step 1) Tile Tab's Initial Screen To configure tiles, select Configure the Tile. To adjust the details of created tiles, select Control the Tile. Step 2) Select "Configure the Tile", and then adjust the Matrix Size. The "Set " button activates only after selecting a group name. It also activates when Matrix Size is the same as or smaller than the number of group monitors. A17 Step 3) Allocate monitor numbers to selected monitors. 10.160.160.169s monitor 10.160.160.168s monitor Step 4) Select a group under Group Input and then adjust the Group Matrix. Click on a Monitor to add it to the current Group. A group with multiple inputs can be selected. Selecting and changing an existing group matrix is also available. A18 Tile Mode(2) Step 5) Select a Tile ID. Tile IDs are manually changeable. Depending an the Group Matrix settings, the Tile ID range can be selected from minimum 1 to maximum 25. The default value is 1, starting from the upper left monitor Step 6) Check the new settings, and then select "Apply". If successful, the window displays Monitor Number, Tile ID, Input, and Group Tile Size as shown in the picture below: A19 Step 7) If the changed settings are successfully transmitted, the "Finish" button becomes activated. Pressing Finish moves back to the initial screen. Tile Mode(3) Step 8) Once a group is set up with monitor tiles, the screen moves back to the initial Tile window. A20 Step 9) Adjust the details of selected tiles. Tiles can be adjusted by selecting their group or a monitor under the group. A21 ">
Download
Advertisement
Key features
LAN + Serial Management
Single/Group WAN Control
Monitor Auto Searching
Self Diagnosis
Scheduling of Power/Input
F/W Upgrade via Network
Instant Messaging
Frequently asked questions
The default ID is Administrator and the password is 0000.
Select Security in the toolbar, enter the current ID and Password, and then enter a new ID and Password in the New Setting window.
Press Search on the toolbar and then either enter an IP address or select SubNet (Broadcast) for automatic searching.
Select 'eZ-Net Manager & Guide' ➞ 'eZ-Net Manager' on the CD-ROM, then follow the on-screen instructions.