advertisement
QuickSpecs
Overview
HP ProLiant ML370 G5 Tower
HP ProLiant ML370 Generation 5
1. Integrated RAID Controller Slot
2. (2) PCI-X 64 Bit/133MHz Slot
3. (6) PCI-Express x4 Slot
4. (8) PC2-5300 Fully Buffered DIMM Slots per memory card -
Standard
5. (8) PC2-5300 Fully Buffered DIMM Slots per memory card -
Optional
6. Dual-Core Intel Xeon processor - Optional
7. Dual-Core Intel Xeon processor - Standard (2 processors standard on all Performance Models)
8. (3) Hot Plug Redundant Fans - Standard
HP ProLiant ML370 G5 Tower call-outs
9. (3) Hot Plug Redundant Fans - Optional
10. System Insight Display (SID)
11. Media Bay Spacer (Tower)/Video Connector (Rack)
12. DVD/CD-ROM Drive
13. Removable Media Bays
14. Front Bezel (Tower Model Only)
15. Hard Drive Bays 1-8 (Serial-attached SCSI (SAS) drives supported - SFF)
16. Hard Drive Bays 9-16 - Optional Drive Cage (Serial-attached
SCSI (SAS) drives supported - SFF)
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 1
QuickSpecs
Overview
HP ProLiant ML370 G5 Rack
HP ProLiant ML370 Generation 5
1. System Insight Display (SID)
2. Video Connector
3. DVD/CD-ROM Drive
4. Removable Media Bays
HP ProLiant ML370 G5 Rack call-outs
5. Hard Drive Bays 1-8 (Serial-attached SCSI (SAS) drives supported - SFF)
6. Hard Drive Bays 9-16 - Optional Drive Cage (Serial-attached
SCSI (SAS) drives supported - SFF)
7. Rack Handles
At A Glance
The flagship ML370 G5 provides industry-leading management, performance and availability in a dual processor expansion server engineered to excel in a variety of environments - from corporate work groups in growing businesses to critical remote sites requiring continuous accessibility and uptime.
Processors:
Dual-core Intel® Xeon™ 5100 & 5000 series processors with 4MB Level 2 cache (2MB per core) for blazing performance
Servers support up to 2 processors (2 processors standard on all Performance models)
Preconfigured Performance models save valuable deployment time at a discounted bundle price
Intel 5000P chipset
Memory:
Maximum 64 GB of PC2-5300 Fully Buffered DIMMs (DDR2-667) running at 667MHz of 4:1 interleaved memory with
Advanced ECC capabilities including Online Spare and Mirrored Memory (8 FB DIMMs per memory card; up to 2 supported)
NOTE: Memory DIMMs in systems with the Front Side Bus (FSB) running at 1333 MHz will run at 667 MHz and in systems with a FSB running at 1066 MHz or 667 MHz the memory DIMMs will run at 533 MHz.
Storage Controller:
Base and Performance Models: Smart Array P400 Controller (SAS RAID)
Entry Models: Smart Array E200 Controller (SAS RAID)
Internal Drive Support:
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 2
QuickSpecs
HP ProLiant ML370 Generation 5
Overview
Up to (16) hot-plug Serial-attached SCSI (SAS) drives supported
(8) drive bays in standard configurations
Optional 8-bay drive cage available for maximum storage support (2nd drive bay cage will require additional SAS controller)
Two open half-height media bays; supports full height internal tape drive
Network Controller:
Embedded Dual NC373i Multifunction Gigabit Network Adapters with TCP/IP Offload Engine, including support for
Accelerated iSCSI through an optional ProLiant Essentials Licensing Kit
Expansion Slots:
Nine total expansion slots
Eight available: (6) PCI-Express x4 and (2) PCI-X 64-Bit/133MHz
USB Ports:
USB 2.0 support
Six total ports: (2) ports up front; (2) ports in back; (2) ports internal (one standard connection and one USB tape connection)
Redundancy:
Optional Hot plug redundant power supplies and cooling fans
Hot plug redundant fans and power supplies included on all Performance models
Management:
New Integrated Lights-Out 2 featuring Integrated Remote Console with KVM over IP performance over shared network access
HP Power Regulator for ProLiant, delivering integrated power monitoring and server level, policy based power management for industry leading energy efficiency and savings on system power and cooling costs
Automatic Server Recovery (ASR), ROM Based Setup Utility (RBSU), HP System Insight Manager, Status LEDs including system health and UID and SmartStart
Systems Insight Display for quick and easy server diagnostics (front drop-down panel)
Form Factor:
5U tower and rack models available (front VGA connection on rack models)
Deployment/Serviceability:
Quick Deploy Rail System includes sliding universal rails, an ambidextrous cable management arm and quick release levers
Tool-less access to all system components for easy in-rack serviceability
Warranty:
Protected by HP Services and a worldwide network of resellers and service providers. Three-year Next Business Day, onsite limited global warranty. Certain restrictions and exclusions apply. Pre-Failure Notification on processors, memory, and hard drives. SATA hard drives have a one-year warranty.
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 3
QuickSpecs
Standard Features
HP ProLiant ML370 Generation 5
NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory
Integrated Models" section.
Dual-Core Intel Xeon Processor 5160 (3.00 GHz, 1333 Front Side Bus (FSB)) Processor
One of the following depending on Model
Dual-Core Intel Xeon Processor 5150 (2.66 GHz, 1333 FSB)
Dual-Core Intel Xeon Processor 5140 (2.33 GHz, 1333FSB)
Dual-Core Intel Xeon Processor 5130 (2.00 GHz, 1333 FSB)
Dual-Core Intel Xeon Processor 5120 (1.86 GHz, 1066 FSB)
Dual-Core Intel Xeon Processor 5110 (1.6 GHz, 1066 FSB)
Dual-Core Intel Xeon Processor 5080 (3.73 GHz, 1066 FSB)
Dual-Core Intel Xeon Processor 5060 (3.2 GHz, 1066 FSB)
Dual-Core Intel Xeon Processor 5050 (3.0 GHz, 667 FSB)
NOTE: Up to 2 processors supported.
NOTE: Performance configurations include two processors.
Cache Memory
One of the following depending on Model
Chipset
4MB (2 x 2MB) Level 2 cache (5000 series)
4MB (1 x 4MB) Level 2 cache (5100 series)
Intel 5000P Chipset
NOTE: For more information regarding Intel chipsets, please see the following URL: http://www.intel.com/products/server/chipsets/ .
Upgradeability Upgradeable to 2 processors
Memory Protection Advanced ECC, Online Spare and Mirroring
NOTE: Mirroring requires optional 2nd memory card.
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 4
QuickSpecs
Standard Features
Memory
One of the following depending on Model
HP ProLiant ML370 Generation 5
Type PC2-5300 Fully Buffered DIMMs (DDR2-667) running at 533 MHz with 4:1 interleaving
NOTE: 4-way interleaving requires optional 2nd memory card.
1 GB (2 x 512 MB) Standard
(Entry Models)
Standard
(Base Models)
Standard
(Performance Models)
Maximum
2 GB (2 x 1 GB)
4 GB (2 x 2 GB)
64 GB (16 x 4 GB with 2 memory cards)
NOTE: Memory DIMMs in systems with the Front Side Bus (FSB) running at 1333 MHz will run at 667
MHz and in systems with a FSB running at 1066 MHz or 667 MHz the memory DIMMs will run at 533
MHz.
Network Controller Embedded Dual NC373i Multifunction Gigabit Network Adapters with TCP/IP Offload Engine, including support for Accelerated iSCSI through an optional ProLiant Essentials Licensing Kit
Expansion Slots Slot
Number
1
2
3
4
5
6
7
Bus Speed
PCI Express x4
64-bit/133MHz PCI-X
64-bit/133MHz PCI-X
PCI Express x4
PCI Express x4
PCI Express x4
PCI Express x4
Bus Device
Number * Number **
PCI
Voltage
6 0 N/A
18
18
14
11
31
28
1
2
0
0
0
0
Notes
3.3 Volt
3.3 Volt
N/A
N/A
Reserved for integrated
RAID controller
Shared bus with slot 3
Shared bus with slot 2
Optional x8 if PCIE expander is installed in slot
4
N/A
N/A Optional x8 if PCIE expander is installed in slot
6
8
9
PCI Express x4
PCI Express x4
25
22
0
0
N/A
N/A Optional x8 if PCIE expander is installed in slot
8
NOTE: x8 cards are supported but will run at x4 speeds. X8 speed can be supported with optional PCIE x4/x8 expansion card option on select slots
*NOTE: Default bus assignment. Inserting cards with PCI bridges may alter the actual bus assignment number.
**NOTE: Slots are enumerated differently based on OS. MS OS's enumerate from lowest to highest
Device ID by bus (starting with the lowest bus).
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 5
QuickSpecs
Standard Features
Storage Controller
One of the following depending on Model
HP ProLiant ML370 Generation 5
Smart Array P400 Controller
NOTE: With 256MB memory module supports RAID 0/1/5.
Available upgrades: 512MB memory module for RAID 0/1/5/6, battery for battery-backed write cache
(BBWC).
Smart Array E200 Controller
NOTE: With 64MB memory module supports RAID 0/1 configurations.
Available upgrades: 128MB memory module for RAID 0/1/5, battery for battery-backed write cache
(BBWC).
Storage Diskette Drive
Optical Drive
One of the following depending on Model
Hard Drives
SCSI (SAS)
None standard
DVD-ROM Drive (Performance Models)
48x IDE CD-ROM Drive (Base and Entry Models)
None standard
576GB
1.15TB
8 x 72GB with standard 8-bay hot plug Serial
SCSI/ATA drive cage
16 x 72GB with optional 2nd SAS drive cage
Remote Management Integrated Lights Out 2 (iLO2) Standard Management:
Virtual Text Remote Console
Virtual Power Button Control
Integrated Remote Console
Dedicated & full function shared network connectivity
Embedded system health
Browser, command line and scripted access
Automatic IP Configuration via DHCP/DNS/WINS
Industry Standard 128-bit Secure Sockets Layer (SSL) and Secure Shell security (SSH)
OS independent hardware health status
IML and iLO Event Logging
Support for 12 user accounts with customizable access privilege
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 6
QuickSpecs
HP ProLiant ML370 Generation 5
Standard Features
Intelligent ManageabilityHP Systems Insight Manager
SmartStart
Management Agent
Redundant ROM
Remote Flash ROM
ROM-Based Setup Utility (RBSU)
Integrated Management Log
Automatic Server Recovery (ASR)
Dynamic Sector Repairing (with Smart Array controller)
Drive Parameter Tracking (with Smart Array controller)
Hot Spare Boot
NOTE: Upon the event of a failed processor in a multi-processing environment, the system will automatically reboot and attempt to use the remaining good processor.
Pre-Failure Warranty (covers processors, SCSI hard drives and memory)
Interfaces
Graphics
Form Factor
ProLiant Essentials
Foundation Pack
Software
Serial 1 (2nd serial and parallel port available via option Kit)
Pointing Device (Mouse) 1
VGA
Keyboard
1 (+1 front VGA on rack models)
1
Network RJ-45 2 iLO 2 remote management 1 port
USB 2.0 Ports 5 (2 on the rear, 2 on the front, 1 internal)
NOTE: Please see the following URL for additional information regarding USB support: http://h18004.www1.hp.com/products/servers/platforms/usbsupport.html
Dedicated USB 2.0 Port 1 (available for DAT USB tape connectivity)
NOTE: Internal USB ports are optimal for the attachment of HP DAT USB
Internal Tape Drives
Integrated ATI ES1000 1280 x 1024 x 16M color (32MB video standard)
Tower and Rack (5U) models available
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 7
QuickSpecs
Standard Features
ProLiant Essentials
Foundation Pack
Software
HP Systems Insight
Manager
SmartStart
Insight Management
Agents
Subscriber's Choice
ROMPaq, support software, and configuration utilities
Insight Diagnostics
HP ProLiant ML370 Generation 5
HP's new HP Systems Insight Manager (HP SIM) helps maximize system uptime and performance and reduce system maintenance costs by providing proactive notification of problems before those problems result in unplanned downtime or reduced productivity. HP SIM are both easy to set up work with the Insight Management Agents, integrated Light-Out and Remote Insight
Light-Outs Edition, and Version Control Agents to deliver robust fault, configuration, and asset management as well as remote administration. With
HP SIM customers will also be able to take advantage of role-based security; the ability to manage ProLiant, Integrity, and HP 9000 systems; and plug-ins for storage, client, printer, and power management as well as server rapid deployment, performance management, and workload management. For more details on HP SIM visit http://www.hp.com/go/hpsim .
SmartStart is a tool that simplifies server setup, providing a rapid way to deploy reliable and consistent server configurations. For more information, please visit the SmartStart Web site at http://www.hp.com/servers/smartstart .
SmartStart version supported (minimum): SmartStart 7.51
The Insight Management Agents form the foundation for HP's Intelligent
Manageability strategy. They provide direct, browser-based access to indepth instrumentation built into HP servers, workstations, desktops, and portables, and send alerts to HP Systems Insight Manager and other enterprise management applications in case of subsystem or environmental failures. For additional information about the Management Agents and other management products from, HP please visit the management Web site at http://www.hp.com/servers/manage .
Subscriber's Choice Driver and Support Alerts/Notifications is a web-based email subscription service that provides automatic delivery of software and driver change notifications for ProLiant products. Sign up at http://www.hp.com/go/subscriberschoice and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis.
The latest software, drivers, and firmware fully optimized and tested for your
ProLiant server and options available in SmartStart or downloadable from
Software and Drivers download pages http://www.hp.com/go/support .
The most advanced configuration analysis, reporting and troubleshooting utilities used by HP and at your fingertips, available in SmartStart.
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 8
QuickSpecs
Standard Features
HP ProLiant ML370 Generation 5
Optional ProLiant Essentials
Value Packs
Optional software offerings that selectively extend the functionality of an
Adaptive Infrastructure to address specific business problems and needs:
Rapid Deployment Pack (RDP) is an automated deployment and provisioning solution for all ProLiant servers. RDP includes the ProLiant
Integration Module featuring ProLiant server pre-configured events for
OS installation, and optimized software drivers, firmware and management agents. Every RDP disc includes 7-day, 10-node trial licenses for evaluation purposes. RDP requires a license for each server deployed and is available for purchase with HP servers. For more information, visit: http://www.hp.com/servers/rdp .
Workload Management Pack - provides easier management of complex environments, improving overall server utilization and enabling Windows 2000 customers for the first time to confidently deploy multiple applications on a single multiprocessor ProLiant Server.
Integrated Lights-Out Advanced Pack - upgrades the Integrated Lights-
Out processor to full virtual presence and control with graphical console and virtual media.
Integrated Lights-Out Select Pack - upgrades the iLO 2 processor with virtual media, power management and enterprise security for text console environments.
Performance Management Pack - identifies and explains hardware performance bottlenecks on ProLiant servers and attached options enabling users to better utilize their valuable resources.
Intelligent Networking Pack - detects and analyzes network bottlenecks or broken network linkages and steers traffic to the optimum route based on network conditions, plus it provides an extra layer of protection. The virus throttle feature of the solution slows the propagation of fast spreading virus
Vulnerability and Patch Management Pack - identifies and remediates software security vulnerabilities due to missing patches as well operating system configurations that can be exploited by viruses, worms, and other blended threats
Virtual Machine Management Pack - provides central management and control of virtual machines from Microsoft and VMware. Integrated approach provides the ability to manage both physical and virtual resources from a single management console.
Server Migration Pack - The Server Migration Pack automates the manual processes required for migrating servers between physical or virtual platforms (P2V, V2P, and V2V).
Accelerated iSCSI Pack - enables the embedded Multifunction network controller to serve as both a NIC and an iSCSI HBA providing access to SAN storage over the same connection used for networking.
Processing of the protocol stack is offloaded to the NIC reducing CPU utilization and greatly improving the speed with which the requests are processed and sent to the network.
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 9
QuickSpecs
Standard Features
HP ProLiant ML370 Generation 5
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to http://www.hp.com/servers/ProLiantessentials or the various ProLiant Essentials Value Pack product
QuickSpecs for more information.
NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/ProLiantessentials .
Industry Standard
Compliance
ACPI 1.0b Compliant
PCI 2.2 Compliant
WOL Support
Microsoft® Logo certifications
PXE Support
Security Power-on password
Keyboard password
Diskette drive control
Diskette boot control
QuickLock, Network Server Mode
Parallel and serial interface control
Administrator's password
Disk configuration lock
Server Power Cords 110V NEMA 12ft. (3.66m) cord included in the United States; localized cables included with geographic specific models in other world regions. IEC 10 ft. (3.05m) cords also included with rack models.
Localized cables included with geographic specific models in other world regions.
Power Supply 800 Watt-CE Mark Compliant Hot Plug Power Supply (1000 Watt high line)
Optional second Power Supply provides redundant capability
NOTE: Please see the "Power Specifications" section later in this document for low line and high line requirements.
UPS and PDU Power
Cord Matrix
Please see the UPS and PDU cable matrix that lists cable descriptions, requirements, and specifications for
UPS and PDU units: ftp://ftp.compaq.com/pub/products/servers/ProLiantstorage/power-protection/powercordmatrix.pdf
.
System Fans Three hot-plug fans standard. Redundant fan kit includes three additional fans.
Required Cabling For external storage cabling information, refer to the Web site at http://h18000.www1.hp.com/products/servers/ProLiantML370/ .
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 10
QuickSpecs
Standard Features
OS Support
HP ProLiant ML370 Generation 5
Microsoft Windows 2000 Server
Windows Server 2003 Server
Novell NetWare
SCO OpenServer and OpenUNIX
LINUX (Red Hat, SuSE, United Linux)
VMware Virtualization Software
NOTE: For more complete and up-to-date information on how to buy server operating systems from HP please visit the OS product site at: http://h18004.www1.hp.com/products/servers/software/OEM.html
NOTE: For a more complete and up-to-date listing of supported OSs and versions, please visit our OS
Support Matrix at: http://www.hp.com/go/supportos
NOTE: For an up-to-date listing of the latest drivers available for the HP ProLiant ML370 G5, please see: http://h18023.www1.hp.com/support/files/server/us/index.html
NOTE: For a more complete and up-to-date information on Linux support, please visit HP Linux Web site at: http://h18000.www1.hp.com/products/servers/linux/hpLinuxcert.html
NOTE: For more information on HP's Certified and Supported ProLiant Servers, please visit the VMware
Server Support Matrix at: http://h18004.www1.hp.com/products/servers/software/vmware/hpvmwarecert.html
The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted servers. The 10000 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the latest processors.
CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear doors, you must allow
830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels of the rack must be a minimum of 2.75 inches (7 cm).
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage.
NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the server, or to the server documentation located in the Support section at the following
URL: http://h18000.www1.hp.com/products/servers/ProLiantdl380/index.html
.
ML370 G5 servers with accommodate both round and square hole rack rails. Telco rack solutions for ProLiant servers are
Round Hole, Third Party or http://www.racksolutions.com/hp .
Telco Racks
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 11
QuickSpecs
Standard Features
HP ProLiant ML370 Generation 5 for Servers and Storage and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking, installation, complex configuration and design services as well as individual factory services, such as image loading, asset tagging, and custom packaging. HP products supported through Factory Express include a wide array of servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000 servers as well as the MSA1000, VA7xxx, EVA, XP, rackable tape libraries and configurable network switches.
For more information on Factory Express services for your specific server model please contact your sales representative or go to http://www.hp.com/go/factory-express .
RoHS Compliant
HP ProLiant Smart
Buys (NA only)
For Resellers in countries/regions with RoHS legislation (see NOTE) (e.g. EU, China, etc.)
The use of the noted material in a solution and subsequent resale of that solution will result in the solution no longer meeting the requirements of RoHS legislation.
NOTE: Directive 2002/95/EC restricts the use of lead, mercury, cadmium, hexavalent chromium, PBBs and PBDEs in electronic products. Countries/regions outside the EU, eg. China, are introducing similar legislation. References to 'RoHS legislation' means requirements of Directive 2002/95/EC or to similar substance restriction legislation enacted by any country/region outside the EU.
The HP Smart Buy program offers mainstream business solutions at competitive prices with excellent availability and superior HP quality. It offers a wide range of industry-leading HP products at compelling prices, allowing you to receive richer configurations with additional options.
NOTE: ProLiant Smart Buys are available in NA only. For detailed specification information on ProLiant
Smart Buys please click on the following link: ftp://ftp.compaq.com/pub/products/servers/smartbuys.pdf
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 12
QuickSpecs
HP ProLiant ML370 Generation 5
Standard Features
Service and Support HP services provide continuous care and support expertise with committed response designed to meet your IT and business needs.
To fully capitalizing on your HP ProLiant servers' capabilities requires a service partner who thoroughly understands your server technology and systems environment. HP Services, an industry leader in provision of multi vender support solutions provides a range of support services designed to meet the varying needs of business. Whether an SMB or large global corporation HP has a ProLiant server support offer to help you speedily deploy and maximize system uptime.
Extended Care - Minimum recommended service support offer designed to ensure customers have access to expert assistance, whenever they need it.
Add services description and part number e.g. ProLiant ML110 3 year 9x5 next business day coverage, excluding holidays - part number.
Committed Care - Cost-effective service options designed to extend HP Services committed response and guaranteed fix times, designed to speed problem resolution.
Add services description and part number e.g. ProLiant ML110 1 3 year 3x5 same business day 4 hour response coverage, excluding holidays - part number.
Committed Response - Highest HP Support service level recommend to help increase IT performance and availability with comprehensive, consistent hardware and software services
Add services description and part number e.g. ProLiant ML110 3 year 24x7 same business day 4 hour response coverage - part number.
Deployment Services - HP Installation and Start Up services designed to take time, risk, and worry out of the deployment of ProLiant servers - and free customers people to focus on what they do best, their business.
Add services description and part number e.g. ProLiant ML110 Installation - part number.
For more information visit: http://www.hp.com/services/proliantservices http://www.hp.com/go/proliant/carepack
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 13
QuickSpecs
Models
HP ProLiant ML370 Generation 5
NOTE: ProLiant Smart Buys are available in NA only. For detailed specification information on ProLiant Smart Buys please click on the following link: ftp://ftp.compaq.com/pub/products/servers/smartbuys.pdf
.
HP ML370 G5
Performance Models
Processor (2) Dual-Core Intel Xeon Processor 5150 (2.66 GHz, 1333 FSB)
Cache Memory
Memory
4MB (1 x 4MB) Level 2 cache - 5100 Series
4 GB (4 x 1 GB); 2 memory cards
Tower Models:
ML370T05 5150
416619-xx1
Network Controller
Storage Controller
Embedded Dual NC373i Multifunction Gigabit NICs
Smart Array P400 Controller with 512MB battery-backed write cache (RAID
0/1/5/6)
Rack Models:
ML370R05 5150
416620-xx1
Hard Drive
Internal Storage
Optical Drive
None ship standard
576GB max - 8 x 72GB SAS drives (with optional hard drives)
DVD-ROM Drive (diskette drive optional)
Form Factor
One of the following depending on Model
Availability
Tower
Rack (5U), (8.75-inch)
Hot Plug Fully Redundant Fans Standard
HP ML370 G5 Base
Models
Tower Models:
ML370T05 5150
417188-xx1
ML370T05 5140
417446-xx1
ML370T05 5060
410635-xx1
Rack Models:
ML370R05 5150
417189-xx1
ML370R05 5140
417447-xx1
ML370R05 5060
410636-xx1
Processor(s)
One of the following depending on Model
Cache Memory
One of the following depending on Model
(1) Dual-Core Intel Xeon Processor 5150 (2.66 GHz, 1333 FSB)
(1) Dual-Core Intel Xeon Processor 5140 (2.33 GHz, 1333 FSB)
(1) Dual-Core Intel Xeon Processor 5060 (3.2 GHz, 1066 FSB)
4MB (1 x 4MB) Level 2 cache - 5100 Series
4MB (2 x 2MB) Level 2 cache - 5000 Series
Memory 2 GB (2 x 1 GB); 1 memory card
Network Controller Embedded Dual NC373i Multifunction Gigabit NICs
Storage Controller
Hard Drive
Smart Array P400 Controller with 256MB cache (RAID 0/1/5)
None ship standard
Internal Storage
Optical Drive
Form Factor
One of the following depending on Model
Availability
576GB max - 8 x 72GB SAS drives (with optional hard drives)
48x CD-ROM Drive (diskette optional)
Tower
Rack (5U), (8.75-inch)
Redundant Power/Fans Optional
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 14
QuickSpecs
Models
HP ML370 G5 Entry
Models
Tower Models:
ML370T05 5120
417444-xx1
Rack Models:
ML370R05 5120
417445-xx1
HP ProLiant ML370 Generation 5
Processor
Cache Memory
(1) Dual Core Intel Xeon Processor 5120 (1.86GHz, 1066 FSB)
2x2MB Level 2 cache (4MB per processor)
Memory 4MB (1 x 4MB) Level 2 cache - 5100 Series
Network Controller Embedded Dual NC373i Multifunction Gigabit NICs
Storage Controller
Hard Drive
Internal Storage
Optical Drive
Form Factor
Availability
Smart Array E200 Controller with 64MB cache (RAID 0/1)
None ship standard
576GB max - 8 x 72GB SAS drives (with optional hard drives)
48x CD-ROM (diskette optional)
Tower
Rack (5U), (8.75-inch)
Redundant Power/Fans Optional
Country Code Key
XX=00
XX=01
XX=03
XX=04
XX=05
XX=20
XX=29
XX=37
XX=42
XX=AA
Tower Code Key
U.S. English
Australia
UK
Germany
France
Brazil
Japan
APD
Europe
PRC
Rack Code Key
U.S. English
N/A
N/A
N/A
N/A
Brazil
Japan
APD
Europe
PRC
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 15
QuickSpecs
HP ProLiant ML370 Generation 5
Configuration Information - Factory Integrated Models (North America only)
NOTE: For Configure to Order requirements within EMEA region, please consult local Sales Contact.
NOTE: HP does not allow factory integration of options into standard models listed above.
Configure-to-order (CTO) servers must start with a CTO Chassis.
NOTE: This product offering does not support HP Factory Express Server Configuration Level 1.
NOTE: FIO indicates that this option only available as a Factory Installable Option.
Step 1: Base Configuration (choose one of the following configurable models)
Models HP ML370 G5 Rack SAS CTO Chassis (North America) 400606-B21
Factory Integrated Model ships with:
Embedded Dual NC373i Multifunction Gigabit NICs
Eight Hot Plug SAS Drive Bays
9 expansion slots - 7 PCI-Express x4 and 2 PCI-X 64-bit 133 MHz
Integrated Lights-Out 2 (iLO2)
800 Watt-CE Mark Compliant Hot Plug Power Supply
Three fans
Rack (5U)
HP ML370 G5 Tower SAS CTO Chassis (North America)
Factory Integrated Model ships with:
Embedded Dual NC373i Multifunction Gigabit NICs
Eight Hot Plug SAS Drive Bays
9 expansion slots - 7 PCI-Express x4 and 2 PCI-X 64-bit 133 MHz
Integrated Lights-Out 2 (iLO2)
800 Watt-CE Mark Compliant Hot Plug Power Supply
Three fans
Keyboard
2-button Mouse
Tower (5U)
400607-B21
Step 1A: Choose SAS Controller (only one of the following)
SAS Controller Smart Array P400/256MB Controller
NOTE: PCI Express
Smart Array P400 Controller/512MB and BBWC
NOTE: PCI Express
HP Smart Array E200/64 Controller
NOTE: PCI Express
HP Smart Array E200/128 Controller
NOTE: PCI Express
Smart Array P600 Controller
NOTE: PCI-X . SA-P600 has internal and external connectors.
405132-B21
411064-B21
409180-B21
411508-B21
337972-B21
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 16
QuickSpecs
HP ProLiant ML370 Generation 5
Configuration Information - Factory Integrated Models (North America only)
Step 2: Choose Required Options (only one of the following from each list)
Processors HP X5160 ML370G5 FIO Kit
HP X5150 ML370G5 FIO Kit
416198-L21
416196-L21
Base Memory
Optical Drives
HP X5140 ML370G5 FIO Kit
HP X5130 ML370G5 FIO Kit
HP X5120 ML370G5 FIO Kit
HP X5110 ML370G5 FIO Kit
HP X5080 ML370G5 FIO Kit
HP X5060 ML370G5 FIO Kit
HP X5050 ML370G5 FIO Kit
NOTE: One additional xxxxxx-B21 processor for each HP ProLiant ML370 server may be ordered.
NOTE: If High Performance Model features are desired, 2nd processor is included in the Performance Pack part numbers in Step 3 below.
1 GB FBD PC2-5300 2 x 512 MB Kit
2 GB FBD PC2-5300 2 x 1 GB Kit
4 GB FBD PC2-5300 2 x 2 GB Kit
8 GB FBD PC2-5300 2 x 4 GB Kit
CD-RW/DVD-ROM Combo Drive Option Kit
HP DVD+R/RW 16X Half Height
DVD-ROM Drive Option Kit
DVD-ROM DRV Kit 16X
CD-ROM 48X FIO
416194-L21
416192-L21
416190-L21
416188-L21
403768-L21
400500-L21
400376-L21
397409-B21
397411-B21
397413-B21
397415-B21
331346-B21
383974-B21
217053-B21
432197-B21
367920-B21
Step 3: Choose Additional Options for Factory Integration
NOTE: For additional options, please refer to the "Options" section below.
Performance Packs The HP ProLiant ML370 G5 Performance Packs are necessary to configure a HP
ProLiant ML370 G5 High Performance Model which includes the latest performance technologies and enterprise class availability features pre-installed for convenience and value. The Performance Pack includes a 2nd processor, redundant fan, power supply, and memory expansion board.
HP ML370G5 5150 HP Pack 430086-B21
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 17
QuickSpecs
Options
HP ProLiant ML370 Generation 5
NOTE: Some options may not be factory configurable. Please contact your local sales representative for additional information.
HP ProLiant ML370
Unique Options
ML370 G5 SAS SFF 8-bay Drive Cage Kit
NOTE: 2nd drive cage requires a storage controller.
401415-B21
403766-B21 ML370 G5 Memory Board Kit
NOTE: 2 Memory Boards required for support of 4:1 interleaving; 2 included with
Performance models.
Tower to Rack Conversion ML370 G5 Kit
X4/X8 PCIE Bus Expander
Hot Plug Redundant Fan ML370 G5 Kit
400899-B21
403724-B21
400693-B21
ProLiant Essentials
Value Pack Software
ProLiant Essentials Integrated Lights-Out Advanced Pack
ProLiant Essentials Integrated Lights-Out Advanced Pack, 1 server
Featuring: sophisticated virtual administration features for ultimate control of servers in the data centers and remote sites.
NOTE: For additional ProLiant Integrated Light-Out Advanced Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11052_div/11052_div.HTML
ProLiant Essentials Integrated Lights-Out Select Pack
263825-B21
ProLiant Essentials Integrated Lights-Out Select Pack, 1 server
Featuring: sophisticated remote control and security features for HP BladeSystem servers and ProLiant ML/DL servers in text console environments.
413119-B21
NOTE: For additional ProLiant Integrated Light-Out Select Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12362_div/12362_div.HTML
ProLiant Essentials Intelligent Networking Pack
ProLiant Essentials Intelligent Networking Pack - Windows Edition, Single Server License
NOTE: For use with a single server. Contains one license with a unique license activation key and documentation.
NOTE: For additional ProLiant Intelligent Networking Pack License Kits please see the
QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12062_div/12062_div.HTML
ProLiant Essentials Intelligent Networking Pack - Linux Edition, Single Server License
NOTE: For additional ProLiant Intelligent Networking Pack - Linux License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12327_div/12327_div.HTML
ProLiant Essentials Performance Management Pack
ProLiant Essentials Performance Management Pack, Single-Server License
NOTE: For use with a single server. Contains one license with a unique license activation key, HP Management CD and documentation.
NOTE: The most recent version of the software can always be downloaded at http://www.hp.com/products/pmp .
372906-B21
397004-B21
306696-B21
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 18
QuickSpecs
Options
HP ProLiant ML370 Generation 5
NOTE: For additional ProLiant Performance Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11925_div/11925_div.HTML
ProLiant Essentials Rapid Deployment Pack
Rapid Deployment Pack, Single-Server License
NOTE: This license allows 1 server to be deployed and managed via RDP.
Rapid Deployment Pack, Single-Server License (Japan)
NOTE: This license allows 1 server to be deployed and managed via RDP.
NOTE: For additional ProLiant Essentials Rapid Deployment Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11053_div/11053_div.HTML
ProLiant Essentials Workload Management Pack
ProLiant Essentials Workload Management Pack, Single Server License
NOTE: For additional ProLiant Workload Management Pack License Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11452_div/11452_div.HTML
ProLiant Essentials Virtualization Management Software
ProLiant Essentials Virtual Machine Management Pack, Single-Server License
NOTE: For use with a single server. Contains one license with a unique license activation key and documentation.
ProLiant Essentials Server Migration Pack, Single-Migration License
NOTE: Contains one license, enabling 1 server migration, with a unique license activation key and documentation.
NOTE: This license allows 1 server to be migrated from a physical server to a virtual machine. Or this license can be used to migrate a virtual machine from one virtualization layer i.e. VMware GSX to a different virtualization layer such as VMware
ESX or Microsoft Virtual Server 2005.
NOTE: For additional ProLiant Essentials Virtualization Management Software License
Kits please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12328_div/12328_div.HTML
ProLiant Essentials Vulnerability and Patch Management Pack
ProLiant Essentials Vulnerability and Patch Management Pack, Single-Server License
NOTE: For use with a single server. Contains one license with a unique license activation key and documentation.
NOTE: For additional ProLiant Vulnerability and Patch Management Pack License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12111_div/12111_div.HTML
ProLiant Essentials Accelerated iSCSI Pack
ProLiant Essentials Accelerated iSCSI Pack, Single Server License
NOTE: For additional Accelerated iSCSI Pack License Kits, please see the QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/12466_div/12466_div.HTML
267196-B21
267196-291
303284-B21
372214-B21
375345-B21
371645-B21
407484-B21
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 19
QuickSpecs
Options
HP ProLiant ML370 Generation 5
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to http://www.hp.com/servers/proliantessentials or the various
ProLiant Essentials Value Pack product QuickSpecs for more information.
NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.hp.com/servers/proliantessentials .
Processor Dual-Core Intel Xeon Processor 5160 (3.00 GHz, 1333 FSB)
Dual-Core Intel Xeon Processor 5150 (2.66 GHz, 1333 FSB)
Dual-Core Intel Xeon Processor 5140 (2.33 GHz, 1333FSB)
Dual-Core Intel Xeon Processor 5130 (2.00 GHz, 1333 FSB)
Dual-Core Intel Xeon Processor 5120 (1.86 GHz, 1066 FSB)
Dual-Core Intel Xeon Processor 5110 (1.6 GHz, 1066 FSB)
Dual-Core Intel Xeon Processor 5080 (3.73 GHz, 1066 FSB)
Dual-Core Intel Xeon Processor 5060 (3.2 GHz, 1066 FSB)
Dual-Core Intel Xeon Processor 5050 (3.0 GHz, 667 FSB)
416198-B21
416196-B21
416194-B21
416192-B21
416190-B21
416188-B21
403768-B21
400500-B21
400376-B21
Memory
Internal Storage
Diskette Drive
Optical Drives
Serial Port Kit
1 GB FBD PC2-5300 2 x 512 MB Kit
2 GB FBD PC2-5300 2 x 1 GB Kit
4 GB FBD PC2-5300 2 x 2 GB Kit
8 GB FBD PC2-5300 2 x 4 GB Kit
ML370 G5 Memory Board Kit
NOTE: 2 Memory Board required for support of 4:1 interleaving; 2 boards included on Performance models.
397409-B21
397411-B21
397413-B21
397415-B21
403766-B21
401415-B21 ML370 G5 SAS SFF 8-bay Drive Cage Kit
NOTE: Optional 2nd drive cage requires a dedicated storage controller.
Floppy Drive ML350/370 G5 Kit
CD-RW/DVD-ROM Combo Drive Option Kit
HP DVD+R/RW 16X Half Height
DVD-ROM DRV Kit 16X
Parallel/Serial Port ML370/350 G5 Kit
409582-B21
331346-B21
383974-B21
432197-B21
401222-B21
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 20
QuickSpecs
Options
Hard Drives
HP ProLiant ML370 Generation 5
SFF SAS - Universal Hot Plug
HP 36GB 3G SAS 10K SFF HDD
HP 72GB 3G SAS 10K SFF HDD
NOTE: Please see the SAS Hard Drive QuickSpecs for Technical Specifications such as capacity, height, width, interface, transfer rate, seek time, physical configuration, and operating temperature: http://h18000.www1.hp.com/products/quickspecs/12244_div/12244_div.HTML
(Worldwide)
SFF SATA Hot Plug
HP 60GB 1.5G SATA 5.4K SFF HDD
NOTE: SATA Drives have a 1-year warranty. Please see the SATA Hard Drive
QuickSpecs for Technical Specifications such as capacity, height, width, interface, transfer rate, seek time, physical configuration, and operating temperature: http://h18000.www1.hp.com/products/quickspecs/12091_div/12091_div.HTML
(Worldwide)
375859-B21
375861-B21
379306-B21
Storage Controllers SAS Controllers
Smart Array P400 Controller
HP Smart Array P400/256MB Controller
NOTE: Supports RAID 0/1/5.
HP Smart Array P400 Controller/512MB and BBWC
NOTE: Supports RAID 0/1/5/6.
512MB Battery-backed cache upgrade
NOTE: Supports the Smart Array P400 Controller.
Battery-backed write cache upgrade
NOTE: Supports the Smart Array P400 Controller.
Smart Array E200 Controller
HP Smart Array E200/128 Controller
HP Smart Array E200/64 Controller
128-MB BBWC (Battery-Backed Write Cache) Enabler
NOTE: Supports the Smart Array E200 Controller, Smart Array 641 Controller, Smart
Array 642 Controller.
Smart Array P600 Controller
HP Smart Array P600 Controller
NOTE: Supports external drive attach.
NOTE: Please see the following SAS Controller QuickSpecs for Technical
Specifications such as PCI Bus, PCI Peak Data Transfer Rate, Protocols supported, Peak
Data Transfer Rate, Channels, Ports, Drives supported, Cache, RAID support, and additional information: http://h18000.www1.hp.com/products/quickspecs/12460_div/12460_div.HTML
(Smart Array E200 Controller) http://h18000.www1.hp.com/products/quickspecs/12400_div/12400_div.HTML
(Smart Array P400 Controller)
405132-B21
411064-B21
405148-B21
383280-B21
411508-B21
409180-B21
351580-B21
337972-B21
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 21
QuickSpecs
Options
HP ProLiant ML370 Generation 5 http://h18000.www1.hp.com/products/quickspecs/12247_div/12247_div.HTML
(Smart Array P600 Controller)
SAS HBA
HP 8 Internal Port SAS HBA with RAID
NOTE: Please see the HBA QuickSpecs for additional information: http://h18004.www1.hp.com/products/quickspecs/12332_div/12332_div.html
SCSI Controllers for External Drive/Storage Support
Smart Array 6402/128 Controller
NOTE: Ultra320 SCSI.
Smart Array 6404/256 Controller
NOTE: Ultra320 SCSI.
Smart Array 642 Controller
NOTE: Ultra320 SCSI.
128-MB BBWC (Battery-Backed Write Cache) Enabler
NOTE: Supports the Smart Array E200 Controller, Smart Array 641 Controller, Smart
Array 642 Controller.
256MB DDR, Battery-Backed Cache Upgrade Kit for SA-6400
NOTE: This 256MB DDR, Battery-Backed Cache upgrade kit supports the Smart Array
6400 series controller only.
Ultra320 Expansion Module for SA-6402
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
NOTE: Please see the following Controller or SCSI Adapter QuickSpecs for Technical
Specifications such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported,
SCSI Peak Data Transfer Rate, Channels, SCSI Ports, Drives supported, Cache, RAID support, and additional information: http://h18000.www1.hp.com/products/quickspecs/11943_div/11943_div.HTML
(Single Channel Ultra320 SCSI HBA) http://h18000.www1.hp.com/products/quickspecs/11587_div/11587_div.HTML
(Smart Array 6400 Series) http://h18000.www1.hp.com/products/quickspecs/12069_div/12069_div.HTML
(Smart Array 642) http://h18000.www1.hp.com/products/quickspecs/10429_div/10429_div.HTML
(SCSI Adapter)
347786-B21
273915-B21
273914-B21
291967-B21
351580-B21
273913-B21
273911-B21
374654-B21
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 22
QuickSpecs
Options
Communications
HP ProLiant ML370 Generation 5
HP NC150T PCI 4-port Gigabit 1000T Combo Switch Adapter
HP NC310F PCI-X 1000SX Gigabit Server Adapter
HP NC320T PCI Express 1000T Gigabit Server Adapter
HP NC340T PCI-X 4-port Gigabit Server Adapter
HP NC370F PCI-X Multifunction 1000SX Gigabit Server Adapter
HP NC370T PCI-X Multifunction 1000T Gigabit Server Adapter
HP NC373F PCI Express Multifunction Gigabit Server Adapter
HP NC380T PCI Express Dual Port Multifunction Gigabit Server Adapter
HP NC1020 PCI 1000T Gigabit Server Adapter
HP NC7170 PCI-X Dual Port 1000T Gigabit Server Adapter
HP NC7170 Low-profile PCI-X Dual Port 1000T Gigabit Server Adapter
HP NC7771 PCI-X 1000T Gigabit Server Adapter
NOTE: Any NIC (except the NC1020) on the option list can be used for redundancy with the embedded Dual NC373i Multifunction Gigabit NICs. When teaming with other NICs or with the embedded NIC, the lack of Jumbo Frames and LSO features on the NC1020 will cause high end NICs to have those features disabled.
367132-B21
368169-B21
367047-B21
391661-B21
374193-B22
374191-B22
394793-B21
394795-B21
353377-B21
313881-B21
383738-B21
290563-B21
Redundant Options Redundant Power Supply 350/370/380 G5 AU Kit
Redundant Power Supply 350/370/380 G5 EU Kit
Redundant Power Supply 350/370/380 G5 JP Kit
Redundant Power Supply 350/370/380 G5 Worldwide Kit
Redundant Power Supply 350/370/380 G5 UK Kit
Redundant Power Supply 350/370/380 G5 US Kit
Hot Plug Redundant Fan ML370 G5 Kit
Tape Drives
NOTE: A separate SCSI Controller is required for connecting SCSI tape drives to this server.
NOTE: For the complete listing of Tape Drive offerings, please see: http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html
For recommended tape drive offerings for this ProLiant server see the following:
USB Tape Drives
HP StorageWorks DAT 72 USB Internal Tape Drive (Carbonite)
Ultrium Tape Drives - Internal, Rack-Mount and Array
HP StorageWorks Ultrium 232 Internal Tape Drive (Carbonite)
HP StorageWorks Ultrium 460 Internal Tape Drive (Carbon)
HP StorageWorks Ultrium 448 Internal Tape Drive (Carbonite)
HP StorageWorks Ultrium 960 Internal Tape Drive (Carbonite)
NOTE: Please see the HP StorageWorks Ultrium Tape Drive QuickSpecs for additional options such as controllers, media, and other related items: http://h18006.www1.hp.com/products/quickspecs/11739_div/11739_div.html
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006
399771-011
399771-021
399771-291
399771-B21
399771-031
399771-001
400693-B21
DW026A
DW064A
Q1518B
DW016A
Q1538A
Page 23
QuickSpecs
Options
HP ProLiant ML370 Generation 5
(Worldwide) http://h18006.www1.hp.com/products/quickspecs/12128_div/12128_div.html
(Worldwide)
For an up-to-date listing of the latest O/S and software support details for HP Ultrium tape drives, please visit: http://www.hp.com/go/connect .
DAT Drives - Internal and Rack-Mount
HP StorageWorks DAT 72 SCSI Internal Tape Drive (Carbon)
NOTE: Please see the DAT Tape Drive QuickSpecs for controllers, media, and other options: http://h18000.www1.hp.com/products/quickspecs/11883_div/11883_div.HTML
(Worldwide)
For an up-to-date listing of the latest O/S and software support details for HP DAT drives, please visit: http://www.hp.com/go/connect
Rack-Mount Tape Drive Enclosures
HP StorageWorks 1U Rack-Mount Kit
NOTE: The 1U Rack-mount Kit can support up to 2 half-height tape drives and is compatible with multiple Single-Ended and LVD SCSI tape drives including DAT 24,
DAT 40, DAT 72, DLT VS80, DLT VS160, Ultrium 215, Ultrium 232, and Ultrium 448 tape drives.
HP StorageWorks 1U USB Rack-Mount Kit
1U USB Cable Option Kit
NOTE: Converts a 1U SCSI rack-mount kit to a USB interface to support the USB tape drives.
HP StorageWorks 3U Rack-Mount Kit
NOTE: The 3U Rack-mount Kit can support up to (2) full-height or (4) half-height tape drives and compatible with multiple Single-Ended and LVD SCSI tape drives including
DAT 24, DAT 40, DAT 72, DLT VS80, DLT VS160, SDLT 320, SDLT 600, Ultrium
215, Ultrium 230, Ultrium 232, Ultrium 460, Ultrium 448 and Ultrium 960 tape drives.
NOTE: Please see the Rack-Mount Tape Drive Kits QuickSpecs for additional information regarding these kits: http://h18000.www1.hp.com/products/quickspecs/10854_div/10854_div.HTML
(Worldwide)
Q1522B
A7445B
A8007A
396114-B21
274338-B22
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 24
QuickSpecs
Options
Tape Autoloaders
HP ProLiant ML370 Generation 5
HP StorageWorks 1/8 Tape Autoloader
HP StorageWorks 1/8 Ultrium 960 Tape Autoloader
HP StorageWorks 1/8 Ultrium 448 Tape Autoloader
HP StorageWorks 1/8 Ultrium 232 Tape Autoloader
1/8 Tape Autoloader Rackmount Kit
NOTE: Required to install the unit in a standard 19-inch rack; includes rails and rackmount instructions.
NOTE: Please reference the 1/8 Tape Autoloader QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs
AF204A
AF203A
AF202A
C9268R
Tape Libraries HP StorageWorks MSL2024 Tape Library
HP StorageWorks MSL2024 1 Ultrium 960 Drive Library
HP StorageWorks MSL2024 1 Ultrium 960 FC Drive Library
HP StorageWorks MSL2024 1 Ultrium 448 Drive Library
HP StorageWorks MSL2024 2 Ultrium 448 Drive Library
HP StorageWorks MSL4048 Tape Library
HP StorageWorks MSL4048 1 Ultrium 448 Drive Library
HP StorageWorks MSL4048 2 Ultrium 448 Drive Library
HP StorageWorks MSL4048 1 Ultrium 960 Drive Library
HP StorageWorks MSL4048 1 Ultrium 960 FC Drive Library
HP StorageWorks MSL4048 2 Ultrium 960 Drive Library
HP StorageWorks MSL4048 2 Ultrium 960 FC Drive Library
HP StorageWorks MSL6000 Tape Library
Ultrium 960 technology
HP StorageWorks MSL6030 1 Ultrium 960 Dr LVDS Library
HP StorageWorks MSL6030 1 Ultrium 960 Dr FC Library
HP StorageWorks MSL6030 2 Ultrium 960 Dr LVDS Library
HP StorageWorks MSL6030 2 Ultrium 960 Dr FC Library
Ultrium 460 technology
HP StorageWorks MSL6030 1 Ultrium 460 Dr LVDS Library
HP StorageWorks MSL6030 1 Ultrium 460 Dr FC Library
HP StorageWorks MSL6030 2 Ultrium 460 Dr LVDS Library
HP StorageWorks MSL6030 2 Ultrium 460 Dr FC Library
NOTE: Please reference the MSL2024, MSL4048 and MSL6000 Tape Library
QuickSpecs at http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at http://www.hp.com/go/ebs .
AG115A
AG326A
AG116A
AG117A
AG320A
AG321A
AG322A
AG324A
AG323A
AG325A
AD606B
AD608B
AD607B
AD609B
AD598B
AD600B
AD599B
AD601B
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 25
QuickSpecs
Options
Software
HP ProLiant ML370 Generation 5
HP DP Express Package for Microsoft Small Business Server
NOTE: To obtain a free licensed copy of HP Data Protector Express for ProLiant edition software, please visit the "Protect Your Data" link accessible from your ProLiant server's
System Management Homepage (SMH) software (SmartStart 7.5 or later).
NOTE: Please see the HP Data Protector Express QuickSpecs for additional information regarding the purchase of HP Data Protector Express software: http://h18000.www1.hp.com/products/quickspecs/12337_div/12337_div.html
(Worldwide)
BB117AP
BB118AA
Cluster Options ProLiant Cluster Starter Kit
NOTE: For additional information regarding the ProLiant Cluster Starter Kit please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11935_div/11935_div.html
(Worldwide)
HP HA/F200 for Entry SAN Cluster
HP HA/F200 for Entry SAN Cluster (Japan)
364023-B21
364026-B22
364026-292
NOTE: For additional information regarding the ProLiant Cluster for Entry Level SAN please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11932_div/11932_div.html
(Worldwide)
NOTE: For configuration/certification options for the HP Parallel Database Cluster for
Oracle RAC please go to: http://www.hp.com/solutions/highavailability/oracle
HP Serviceguard for Linux ProLiant Cluster A.11.16 for SUSE SLES 9 and Red Hat EL 3
& 4 (2 node license cluster kit)
HP Serviceguard for Linux A.11.16 for SUSE SLES9 and Red Hat EL 3 & 4 (single license version)
HP Serviceguard for Linux and Red Hat Global File System - 1 year subscription
305199-B26
307754-B26
T2798AA#001
HP Serviceguard for Linux and Red Hat Global File System - 3 years subscription
NOTE: For additional information regarding the HP Serviceguard for Linux License, please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11518_div/11518_div.html
(Worldwide)
NOTE: For configuration/certification options for HP Serviceguard for Linux please go to: http://www.hp.com/info/sglx
T2798AA#003
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 26
QuickSpecs
Options
StorageWorks
Options
HP ProLiant ML370 Generation 5
NOTE: For the complete listing of Fibre Channel Host Bus Adapters for Windows
2000, Windows Server 2003 and Linux, please see: http://h18006.www1.hp.com/storage/saninfrastructure/hba.html
StorageWorks 2 Gb, 64-bit/133 MHz PCI-X-to-Fibre Channel Host Bus Adapter for
Windows, Linux and Netware
StorageWorks 2 Gb, Dual Port, 64-Bit/133 MHz PCI-X-to-Fibre Channel Host Bus
Adapter Windows, Linux and Netware
HP StorageWorks 2 Gb, single channel, 133 MHz PCI-X-to-Fibre Channel Host Bus
Adapter Windows and Linux
HP StorageWorks 2 Gb, dual channel, 133 MHz PCI-X-to-Fibre Channel Host Bus
Adapter Windows and Linux
HP StorageWorks FC2142SR 4Gb PCI-E HBA for Windows and Linux
HP StorageWorks FC2242SR Dual Channel 4 Gb PCI-E HBA for Windows and Linux
HP StorageWorks FC1142SR 4Gb PCI-E HBA for Windows and Linux
HP StorageWorks FC1242SR Dual Channel 4 Gb PCI-E HBA for Windows and Linux
HP StorageWorks FC2143 4Gb PCI-X 2.0 HBA for Windows and Linux
HP StorageWorks FC2243 4Gb PCI-X 2.0 DC HBA for Windows and Linux
281541-B21
321835-B21
A7388A
A7387A
A8002A
A8003A
AE311A
AE312A
AD167A
AD168A
HP StorageWorks HP StorageWorks Modular Smart Array 20 redundant power supplies.
HP StorageWorks Modular Smart Array 20 Starter Kit
NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies. Includes Smart Array 6402/128 Controller.
NOTE: The Modular Smart Array Enclosure 20 Family supports the SATA 1.5Gb/s
3.5" Hot Plug Hard Drives.
335921-B21
366172-B21
HP StorageWorks HP StorageWorks Modular Smart Array 30 SB
HP StorageWorks Modular Smart Array 30 DB
NOTE: Rack-mountable 14 drive enclosure with dual bus, redundant power supplies.
NOTE: The Modular Smart Array Enclosure 30 Family supports the Wide Ultra3,
Ultra320 Hot Plug Hard Drives.
302969-B21
302970-B21
HP StorageWorks HP StorageWorks Modular Smart Array 50 Enclosure configuration information at http://h18000.www1.hp.com/products/quickspecs/12245_div/12245_div.HTML
(Worldwide)
364430-B21
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 27
QuickSpecs
HP ProLiant ML370 Generation 5
Options
HP StorageWorks
Modular Smart Array
500
HP StorageWorks Modular Smart Array 500 Generation 2
NOTE: Please see the Modular Smart Array 500 Generation 2 QuickSpecs for additional information including configuration steps and additional options needed for a complete solution at: http://h18000.www1.hp.com/products/quickspecs/11956_div/11956_div.HTML
(Worldwide)
335880-B21
HP StorageWorks
Modular Smart Array
1000
HP StorageWorks Modular Smart Array 1000
NOTE: Please see the Modular Smart Array 1000 QuickSpecs for additional options and configuration information at http://h18000.www1.hp.com/products/quickspecs/11033_div/11033_div.HTML
(Worldwide)
201723-B22
HP StorageWorks
Modular Smart Array
1500 cs
Modular Smart Array 1500 Controller Shelf
NOTE: Please see the StorageWorks Modular SAN Array 1500 cs QuickSpecs for additional options and configuration information at: http://www.hp.com/go/MSA1500cs
AA986A
Uninterruptible Power HP UPS R1500 XR (1440VA, 1340 Watt), Low Voltage (NA)
HP UPS R1500 XR (1500VA, 1340 Watt), Low Voltage (Japan)
HP, R1.5kVA UPS, 1U, NA
HP, R1.5kVA UPS, 1U, INTL
HP, R1.5kVA UPS, 1U, JPN/TW
HP UPS R3000 XR (2880VA, 2700 Watt), Low Voltage (NA)
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (NA)
HP UPS R3000 XR (2400VA, 2250 Watt), Low Voltage (Japan)
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (Japan)
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (Int'l - detachable cord)
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A IEC309 Plug)
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A CEE 7/7 SCHUKO
Plug)
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A BS-546 Plug)
HP R3000 VA UPS, 2U, DTC, INTL
HP R3000 VA UPS, 2U, L5-30, NA
HP R3000 VA UPS, 2U, L6-20, NA
HP R3000 VA UPS, 2U, L6-20, JPN
HP R3000 VA UPS, 2U, L5-30, JPN
HP UPS R5500 XR (5000VA, 4500 Watt), High Voltage (NA/Jpn)
HP UPS R5500 XR (6000VA, 5400 Watt), High Voltage (Int'l)
204404-001
204404-B31
204404-291
AF419A
AF418A
AF421A
192186-001
192186-002
192186-291
192186-292
192186-B31
192186-B32
192186-B33
192186-AR1
AF414A
AF422A
AF423A
AF424A
AF425A
326529-D71
326529-B31
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 28
QuickSpecs
Options
HP ProLiant ML370 Generation 5
HP R5500 VA UPS, INTL
HP R5500 VA UPS, NA/JPN
HP UPS R12000 XR, N+ x (12KVA, 12KW), High Voltage (WW)
NOTE: The UPS R12000 XR has a hardwired input and output connection.
AF416A
AF426A
207552-B22
HP Monitored Power
Distribution Unit (PDU)
HP Monitored Power Distribution Unit: Full Rack Version
HP 17.3 kVA S2324 Monitored PDU- dual input, 3-phase, 24A (NA/JPN)
HP 8.3 kVA S1324 Monitored PDU- single input, 3-phase, 24A (NA/JPN)
HP 16.6 kVA S2140 Monitored PDU- dual input, 1-phase, 40A (NA/JPN)
HP 8.6 S1140 Monitored PDU- single input, 1-phase, 40A (NA/JPN)
HP 22.1 kVA S2316 Monitored PDU- dual input, 3-phase, 16A (INTL)
HP 11 kVA S 1316 Monitored PDU- single input, 3-phase, 16A (INTL)
HP 14.7 kVA S2132 Monitored PDU- dual input, 1-phase, 32A (INTL)
HP 7.4 kVA S1132 Monitored PDU- single input, 1-phase, 32A (INTL)
17.3 kVA Monitored PDU Model S2324
8.6 kVA Monitored PDU Model S1324
16.6 kVA Monitored PDU Model S2140
8.3 kVA Monitored PDU Model S1140
22 kVA Monitored PDU Model S2316
11 kVA Monitored PDU Model S1316
14.7 kVA Monitored PDU Model S2132
7.3 kVA Monitored PDU Model S1132
4.9kVA Monitored PDU model S124
7.3kVA Monitored PDU model S132
370959-D71
370960-D71
370961-D71
370962-D71
370963-B31
370964-B31
370965-B31
370966-B31
AF503A
AF504A
AF505A
AF506A
AF507A
AF508A
AF509A
AF510A
AF914A
AF915A
Modular Power Fixed Cord Extension Bars
(up to 32 outlets)
NOTE: 1U/0U mounting brackets shipped with
Fixed Cord PDU (NA/JPN)
NOTE: Four Fixed Cord Extension Bars, and one 24A, HV mPDU L6-30P core.
Fixed Cord PDU (INTL) the unit (optimized for
10000 and 9000 series
NOTE: Four Fixed Cord Extension Bars, and one 32A, HV mPDU IEC-309 core.
racks).
HP Modular Power Distribution Units (mPDU), Low Volt Model, 24A (100-127 VAC)
(NA, Japan)
NOTE: This mPDU (252663-D71) may also be used to connect the low volt model of the UPS R3000 XR.
HP Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240 VAC)
(NA, Japan)
HP Modular Power Distribution Units (mPDU), High Volt Model, 32A (200-240 VAC)
(Int'l)
351655-B21
351655-D72
351655-B31
252663-D71
252663-D72
252663-B31
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 29
QuickSpecs
Options
HP ProLiant ML370 Generation 5
HP Modular Power Distribution Units (mPDU), High Volt Model, 40A (200-240 VAC)
(WW)
NOTE: This mPDU (252663-B21), 40A model has a hardwired input.
HP Modular Power Distribution Units (mPDU), High Volt Model, 16A (200-240 VAC)
(WW)
HP Modular Power Distribution Units (mPDU), High Volt Model, 40A, Attached Cord
(NA/JPN)
HP Modular Power Distribution Units (mPDU), High Volt Model, 40A, Attached Cord
(Int'l)
NOTE: This PDU has a detachable input power cord and allows for adaptability to country specific power requirements. This model may also be used with the high volt
UPSs R3000 XR and R6000 For North America, need to order cable PN 340653-
001.
NOTE: Please see the following Modular Power Distribution Unit (Zero-U/1U Modular
PDUs) QuickSpecs for additional options including shorter jumper cables and country specific power cords: http://h18000.www1.hp.com/products/quickspecs/11041_div/11041_div.HTML
(Worldwide)
252663-B21
252663-B24
252663-D73
252663-B32
HP Rack 5000 Series
(Graphite Metallic)
HP 5642 Rack-Unassembled
NOTE: Please see the HP Rack 5642 QuickSpecs for additional part numbers and
Technical Specifications such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12074_div/12074_div.HTML
(Worldwide)
NOTE: For additional information regarding Rack Cabinets, please see the following
URL: http://www.hp.com/go/rackandpower .
358254-B21
HP Rack 10000 G2
Series
(Carbon/Graphite
Metallic)
10642 G2 (42U) Rack Cabinet - Pallet
10642 G2 (42U) Rack Cabinet - Shock Pallet
10642 G2 (42U) Rack Cabinet - Crated
10642 G2 (42U) Rack Cabinet, with Extension - Shock Pallet
10642 G2 (42U) Rack Cabinet, without door - Shock Pallet
10642 G2 (42U) Rack Cabinet - with Extension, without door - Shock Pallet
10636 G2 (36U) Rack Cabinet - Pallet
10636 G2 (36U) Rack Cabinet - Shock Pallet
10636 G2 (36U) Rack Cabinet - Crated
10636 G2 (36U) Rack Cabinet, with Extension - Shock Pallet
10636 G2 (36U) Rack Cabinet, without door - Shock Pallet
10636 G2 (36U) Rack Cabinet, with Extension, without door - Shock Pallet
NOTE: It is mandatory to use a shock pallet when shipping racks with equipment installed.
AF001A
AF002A
AF003A
AF004A
AF005A
AF006A
AF011A
AF012A
AF013A
AF014A
AF015A
AF016A
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 30
QuickSpecs
Options
HP ProLiant ML370 Generation 5
NOTE: Please see the Rack 10000 G2 QuickSpecs for Technical Specifications such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12402_div/12402_div.HTML
(Worldwide)
NOTE: For additional information regarding Rack Cabinets, please see the following
URL: http://www.hp.com/go/rackandpower .
HP Rack 10000 Series 10642 (42U) Infrastructure Rack (Low Voltage)
(Graphite Metallic)
10642 (42U) Infrastructure Rack (High Voltage)
HP S10614 (14U) Rack Cabinet - Shock Pallet
HP Rack 10842 (42U, 800mm wide) - Pallet
HP Rack 10842 (42U, 800mm wide) - Shock Pallet
HP Rack 10647 (47U) - Pallet
HP Rack 10647 (47U) - Crated
HP Rack 10642 (42U) - Pallet
HP Rack 10642 (42U) - Shock Pallet
HP Rack 10642 (42U) - Crated
HP Rack 10636 (36U) - Pallet
HP Rack 10636 (36U) - Shock Pallet
HP Rack 10636 (36U) - Crated
HP Rack 10622 (22U) - Pallet
HP Rack 10622 (22U) - Shock Pallet
HP Rack 10622 (22U) - Crated
NOTE: xxxxxx-B21 (pallet) used to ship empty racks shipped on a truck. -B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and
Channels). xxxxxx-B23 (crated) used for air shipments of empty racks.
NOTE: It is mandatory to use a shock pallet in order to ship racks with equipment installed. Not all HP equipment is qualified to be shipped in the Rack 10000 series.
NOTE: Please see the Rack 10000 QuickSpecs for Technical Specifications such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/10995_div/10995_div.HTML
(Worldwide)
NOTE: For additional information regarding Rack Cabinets, please see the following
URL: http://www.hp.com/go/rackandpower .
379006-001
379005-001
292302-B22
257415-B21
257415-B22
245160-B21
245160-B23
245161-B21
245161-B22
245161-B23
245162-B21
245162-B22
245162-B23
245163-B21
245163-B22
245163-B23
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 31
QuickSpecs
HP ProLiant ML370 Generation 5
Options
Keyboards and MonitorsTFT7210R Rack Mounted 17" Monitor
NOTE: For a complete list of Monitors please view the following URL: http://www.hp.com/go/kvm .
TFT7600 Rackmount Keyboard Monitor US
TFT7600 Rackmount Keyboard Monitor UK
TFT7600 Rackmount Keyboard Monitor GR
TFT7600 Rackmount Keyboard Monitor FR
TFT7600 Rackmount Keyboard Monitor IT
TFT7600 Rackmount Keyboard Monitor SP
TFT7600 Rackmount Keyboard Monitor DEN
TFT7600 Rackmount Keyboard Monitor NOR
TFT7600 Rackmount Keyboard Monitor SE/FI
TFT7600 Rackmount Keyboard Monitor SWI
TFT7600 Rackmount Keyboard Monitor PORT
TFT7600 Rackmount Keyboard Monitor BEL
TFT7600 Rackmount Keyboard Monitor JPN2
TFT7600 Rackmount Keyboard Monitor RUS
TFT7600 Rackmount Keyboard Monitor INTL
1U Rackmount Keyboard with USB, US
1U Rackmount Keyboard with USB, UK
1U Rackmount Keyboard with USB, GR
1U Rackmount Keyboard with USB, FR
1U Rackmount Keyboard with USB, ITL
1U Rackmount Keyboard with USB, SP
1U Rackmount Keyboard with USB, DEN
1U Rackmount Keyboard with USB, NOR
1U Rackmount Keyboard with USB, SE/FI
1U Rackmount Keyboard with USB, SWI
1U Rackmount Keyboard with USB, PORT
1U Rackmount Keyboard with USB, BEL
1U Rackmount Keyboard with USB, JPN2
1U Rackmount Keyboard with USB, RUS
1U Rackmount Keyboard with USB, INTL
NOTE: For additional information regarding Rack Cabinets, please see the following
URL: http://www.hp.com/go/rackandpower .
348373-B21
AG065A
AG066A
AG072A
AG073A
AG074A
AG075A
AG076A
AG077A
AG078A
AG079A
AG080A
AG081A
AG082A
AG083A
AG084A
AG085A
AG086A
AG052A
AG053A
AG054A
AG055A
AG056A
AG057A
AG058A
AG059A
AG060A
AG061A
AG062A
AG063A
AG064A
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 32
QuickSpecs
HP ProLiant ML370 Generation 5
Options
HP KVM Switch Options2x1x16 IP Console Switch with Virtual Media
4x1x16 IP Console Switch with Virtual Media
2x16 Server Console Switch with Virtual Media
PS/2 Virtual Media Interface Adapter, 1 pack
NOTE: Requires PS/2 and one USB port on server.
Server Console Switch (KVM), 0 x 1 x 8 port
Server Console Switch (KVM), 0 x 2 x 16 port
PS/2 Interface Adapter, 1 pack
PS/2 Interface Adapter, 8 pack
USB Interface Adapter, 1 pack
Serial Interface adapter - 1 Pack with power supply
NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches.
Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm .
HP 1x 4 USB/PS2 KVM Switch, TT (NA/JPN)
AF601A
AF602A
AF600A
AF604A
336044-B21
336045-B21
262588-B21
262587-B21
336047-B21
373035-B21
HP 1x 4 USB/PS2 KVM Switch, TT (AU/NZ)
HP 1x 4 USB/PS2 KVM Switch, TT (UK)
HP 1x 4 USB/PS2 KVM Switch, TT (EU)
HP 1x 4 USB/PS2 KVM Switch, RM (ALL)
371301-D71
371301-011
371301-031
371301-A21
371302-B21
HP PS2 KVM Cable with audio, 6', 2-pack
HP USB KVM Cable with audio, 6', 2-pack
371730-B21
371729-B21
NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm .
Options
HP 48 Port Serial Console Server (worldwide)
Serial Adapter, RJ45-DB9 DCE Female, 1 Pack
Serial Adapter, RJ45-DB9 DCE Female, 8 Pack
NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console
Servers. Additional Serial Adapters and Cat5e cables can be found at the following
URL: http://www.hp.com/go/kvm .
NOTE: For additional information regarding KVM switches, Serial Console servers, rack mount monitors, keyboards and all related options please see the following URL: http://www.hp.com/go/kvm .
AF101A
AF102A
AF103A
AF110A
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 33
QuickSpecs
HP ProLiant ML370 Generation 5
Options
Service and Support
Offerings (HP Care Pack
Hardware Services On-site Service
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic
Services)
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic
Hardware Services 6-Hour Call to Repair On-site Service
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years,
Electronic
Installation & Start-up Services
Hardware Installation, Electronic
Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the
Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-
5pm, M-F, excl. HP holidays, Electronic
Support Plus
Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays, Electronic
Support Plus 24
Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic
Onsite HW support 24x7, 4hr response and SuSE Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic
Onsite HW support 24x7, 4hr response and Red Hat ES Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic
NOTE: For more information, customer/resellers can contact http://www.hp.com/services/carepack .
U4528E
U4529E
U4530E
U4538E
U4539E
U4540E
U4541E
U6311E
U8333E
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 34
QuickSpecs
Memory
HP ProLiant ML370 Generation 5
NOTE: Memory configurations listed do not apply to "Factory Integrated Models".
NOTE: Memory DIMMs in systems with the Front Side Bus (FSB) running at 1333 MHz will run at 667 MHz and in systems with a
FSB running at 1066 MHz or 667 MHz the memory DIMMs will run at 533 MHz.
HP ProLiant ML370 G5 Models
Minimum Memory
1 GB PC2-5300 Fully Buffered DIMMs (DDR2-667) running at 533 MHz (2 x 512 MB)
Maximum Memory Replaced with Optional Memory
Up to 64 GB of memory is available with the removal of the standard 1 GB of memory. With 2 memory cards: 4 GB PC2-5300
Fully Buffered DIMMs (DDR2-667) running at 533 MHz (16 x 4 GB with 2 memory cards).
NOTE: Not all FB DIMM sizes available at product launch.
NOTE: This chart does not represent all possible memory configurations.
NOTE: Memory DIMMs in systems with the Front Side Bus (FSB) running at 1333 MHz will run at 667 MHz and in systems with a
FSB running at 1066 MHz or 667 MHz the memory DIMMs will run at 533 MHz.
Memory
Standard
Maximum
1 GB
64 GB
1 st
card
2 nd
card
1 2 3 4
Slot
5 6 7 8
512 MB Empty Empty Empty 512 MB Empty Empty Empty
4 GB
4 GB
4 GB
4 GB
4 GB
4 GB
4 GB
4 GB
4 GB
4 GB
4 GB
4 GB
4 GB
4 GB
4 GB
4 GB
Following are memory options available from HP:
1 GB FBD PC2-5300 2 x 512 MB Kit
2 GB FBD PC2-5300 2 x 1 GB Kit
397409-B21
397411-B21
4 GB FBD PC2-5300 2 x 2 GB Kit
" 8 GB FBD PC2-5300 2 x 4 GB Kit
397413-B21
397415-B21
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 35
QuickSpecs
Storage
HP ProLiant ML370 Generation 5
A
B, C
1-16
Drive Support
Removable Media
IDE CD-ROM Drive
DVD-ROM Drive Option
Kit (optional)
Quantity
Supported
Up to 2
Up to 2
Position
Supported
A, B
A, B
Controller
Integrated IDE
Integrated IDE
DVD-ROM Drive (Performance Models)/48x IDE
CD-ROM Drive (Base and Entry Models)
DVD-ROM Drive (Performance Models)/48x IDE
CD-ROM Drive (Base and Entry Models)
(16) hot-plug Serial-attached SCSI (SAS) drives supported
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 36
QuickSpecs
Storage
Hard Drives
Serial-ATA (SATA) - Hot Plug Drives
Quantity
Supported
60GB 1.5G SATA 5.4K
Up to 16
HP ProLiant ML370 Generation 5
Position
Supported Controller
1-16 Smart Array P400 Controller
Smart Array E200 Controller
Smart Array P600 Controller
SFF SAS - Hot Plug Drives
Quantity
Supported
36GB 3G SAS 10K
72GB 3G SAS 10K
Up to 16
Position
Supported Controller
1-16 Smart Array P400 Controller
Smart Array E200 Controller
Smart Array P600 Controller
External Storage
Modular Smart Array 20
Family
Modular Smart Array 30
Family
Quantity
Supported
1 per external
VHDCI SCSI connector
1 per external
VHDCI SCSI connector
Position
Supported Host Controller or Adapter
External Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
External Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 642 Controller
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
Smart Array P600 Controller Modular Smart Array 50
Enclosure
Modular Smart Array 500
G2 System
1
1 per external
VHDCI SCSI connector
External
External
Modular Smart Array
1000
Smart Array 642 Controller (used as Host Bus Adapter)
Please see the Modular Smart Array 500 G2 QuickSpecs for the latest list of supported HBAs: http://www.hp.com/go/msa500
Please see the Modular Smart Array 1000 QuickSpecs (URL below) for the latest list of supported HBAs
Modular Smart Array
1500 cs
Please see the
Modular Smart
Array 1000
QuickSpecs link below to determine configuration requirements
Please see the
Modular Smart
Array 1500 cs
QuickSpecs link below to
External
External Please see the Modular Smart Array 1500 cs QuickSpecs (URL below) for the latest list of supported HBAs
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 37
QuickSpecs
HP ProLiant ML370 Generation 5
Storage determine configuration requirements
Modular Smart Array 1000: http://h18000.www1.hp.com/products/quickspecs/11033_div/11033_div.HTML
(Worldwide)
Modular Smart Array 1500 cs: http://www.hp.com/go/MSA1500cs
Tape Drives, Tape Autoloaders, & Tape Libraries
NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Drives listed below, please see the following: http://h18000.www1.hp.com/products/quickspecs/Division/10233.html
(Worldwide)
NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Autoloaders and Tape Libraries listed below, please see the following: http://h18000.www1.hp.com/products/quickspecs/Division/10809.html
(Worldwide)
NOTE: For complete listing of tape drive offerings see http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html
For recommended tape drive offerings for this ProLiant server see the following:
Quantity
Supported
Position
Supported Controller
1 B + C Embedded USB 2.0 Port HP StorageWorks Tape
Drives, Internal
DAT 24 USB
DAT 40 USB
DAT 72 USB
HP StorageWorks Tape
Drives, External
DAT 24 USB
DAT 40 USB
DAT 72 USB
1 External USB 2.0 Port
HP StorageWorks Tape
Drives, Internal
Ultrium 232
Ultrium 448
Ultrium 460
DAT 40
DAT 72
DLT VS80
DLT VS160
SDLT 320
Up to 2 B + C 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 38
QuickSpecs
Storage
HP StorageWorks Tape
Drives, Internal
Ultrium 960
SDLT 600
HP StorageWorks Tape
Drives, External
Ultrium 232
Ultrium 448
Ultrium 460
DAT 40
DAT 72
DLT VS80
DLT VS160
SDLT 320
HP StorageWorks Tape
Drives, External
Ultrium 960
SDLT 600
HP StorageWorks Rackmount Tape Drive
Enclosures
1U Rack-Mount Kit
3U Rack-Mount Kit
1
Up to 2
1 per SCSI channel
1 per SCSI channel
HP StorageWorks
Autoloaders, External
1/8 Tape Autoloader
1 autoloader per
SCSI channel
HP StorageWorks Tape Please reference
Libraries, External
MSL2024 (Ultrium 448 the MSL Tape
Library and 960-based)
MSL4048 (Ultrium 448 and 960-based)
MSL6000 (Ultrium 960
QuickSpecs to determine configuration requirements and 460-based)
MSL6000 (SDLT 600based)
B + C
HP ProLiant ML370 Generation 5
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
External 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
External 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
External 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
External 64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
External Please consult the EBS connectivity matrix at http://www.hp.com/go/ebs for detailed connectivity information.
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 39
QuickSpecs
Power Specifications
HP ProLiant ML370 Generation 5
Part Number 380622-001
Spare Kit 403781-001
Operational Input Voltage Range (V 90 to 264 rms)
Frequency Range (Nominal) (Hz) 47 to 63 (50/60)
Nominal Input Voltage (Vrms)
Max Rated Output Wattage Rating
Nominal Input Current (A rms)
Max Rated Input Wattage Rating
(Watts)
Max. Rated VA (Volt-Amp)
Efficiency (%)
Power Factor
Leakage Current (mA)
Maximum Inrush Current (A peak)
Maximum Inrush Current duration (mS)
NOTES:
100
800
10.0
980
1000
81.5
0.98
0.44
30
3
120
950
8.8
1035
1056
82
0.98
0.52
30
3
208
1000
5.85
1193
1217
84
0.98
0.91
30
3
220
1000
5.5
1186
1210
84
0.98
0.96
30
3
230
1000
5.2
1172
1196
85
0.98
1.00
30
3
240
1000
4.97
1169
1193
85.5
0.98
1.04
30
3
The Active Answers Power Calculator should be used prior to deployment to determine the system power ratings. For proper operation, ensure the nominal input voltage selected (e.g. low line or high line) provides a max rated output wattage rating greater than the system power ratings.
The Active Answers Power Calculator is available via the online tool located at URL: http://h30099.www3.hp.com/configurator/powercalcs.asp
.
To drill down to calculators:
Click on: "ProLiant Servers"
Click on the Server of interest. Example: ML370 G5
Click on: "Power Calculator" link. (You may need to scroll down to see it)
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 40
QuickSpecs
Power Specifications
Power Cords (13 Cord Sets)
Country
APD
APD
APD
Australia
Europe
France
Germany
Japan
PRC
PRC
PRC
UK
US
HP ProLiant ML370 Generation 5
Power Cord Part Number
139867-006
100613-003
100614-003
100611-007
100614-003
100614-003
100614-003
139867-006
139867-006
100613-003
100661-007
100613-003
163719-002
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 41
QuickSpecs
Technical Specifications
HP ProLiant ML370 Generation 5
System Unit - Tower Dimensions (H x W x D) 8.63 x 17.5 x 26.5 in (21.92 x 44.45 x 67.31 cm)
Weight Tower: 1 Processor, 1 hard drive cage, 1
Memory Board, 1 Power
Supply, 1 Controller card,
3 fans
Tower: 1 Processor,
1HDD, 1 Memory Board,
2 Power Supplies, 2
Controller cards, 6 fans
68 lbs (30.84 kg)
77 lbs (34.93 kg)
Input Requirements Range Line Voltage
Rated Input Voltage
Rated Input Frequency
100-132 VAC, 200-240 VAC
7.5A (100VAC), 3.8A (200VAC)
50 to 60 Hz
Rated Input Current
Rated Input Power
735W
1001W (100VAC)
BTU Rating 3,420 BTU/HR
Power Specifications To review typical system power ratings use the Active Answers Power
Calculator which is available via the online tool located at URL: http://h30099.www3.hp.com/configurator/powercalcs.asp
.
To drill down to calculators:
- Click on: "ProLiant Servers"
- Click on the Server of interest. Example: ML370 G5
- Click on: "Power Calculator" link. (You may need to scroll down to see it)
Power Supply Output
Power
Steady State Power
Maximum Peak Power
775W
775W
Temperature Range Operating
Relative Humidity
(non-condensing)
Acoustic Noise
Shipping
Operating
Shipping
Idle
(Fixed Disk Drives
Spinning)
L WAd (BELS)
L pAm (dBA)
Operating
(Random Seeks to Fixed
Disks)
L WAd (BELS)
L pAm (dBA)
41° to 95° F (5° to 35° C)
-40° to 185° F (-40° to 85° C)
5% to 95%
5% to 95%
5.9
41
6.0
42
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 42
QuickSpecs
HP ProLiant ML370 Generation 5
Technical Specifications
System Unit - Rack Dimensions (H x W x D) 8.63 x 17.5 x 26.5 in (21.92 x 44.45 x 67.31 cm)
Weight Rack (no skins): 1
Processor, 1Hard drive cage, 1 Memory Board, 1
Power Supply, 1 Controller card, 3 fans
59 lbs (26.76 kg)
Input Requirements
Rack (no skins): 1
Processor, 2 Hard Drive cages, 1 Memory Board,
2 Power Supplies, 2
Controller cards, 6 fans
Range Line Voltage
Rated Input Voltage
Rated Input Frequency
68 lbs (30.84 kg)
90 to 264 VAC
100 to 240 VAC
47 to 63 Hz
10A (110 V) to 4.8A (220 V)
1001W (100VAC)
Rated Input Current
Rated Input Power
3,420 BTU/HR BTU Rating
Power Supply Output
Power
Steady State Power
Maximum Peak Power
Temperature Range Operating
775W
775W
41° to 95° F (5° to 35° C)
Relative Humidity
(non-condensing)
Shipping
Operating
Shipping
101.7° F (38.7° C) Maximum Wet Bulb
Temperature
Acoustic Noise
-40° to 185° F (-40° to 85° C)
5% to 95%
5% to 95%
Idle
(Fixed Disk Drives
Spinning)
L WAd (BELS)
L pAm (dBA)
Operating
(Random Seeks to Fixed
Disks)
L WAd (BELS)
L pAm (dBA)
5.9
41
6.0
42
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 43
QuickSpecs
HP ProLiant ML370 Generation 5
Technical Specifications
Smart Array P400
Controller
Disk Drive and Enclosure 3G SAS (Serial Attached SCSI)
Interface
1.5G SATA (Serial Advanced Technology Attachment)
SAS Connectors 2 internal (SFF8484) x4 wide port connectors
Cache Memory Speed DDR2-533MHz with 40 or 72-bit wide bus provides up to 4.2 GB/s maximum bandwidth.
Server Interface x8 2.5G PCIe provides 2GB/s maximum bandwidth.
SAS Speed
Cache Memory x8 3G SAS provides 2.4GB/s maximum bandwidth.
40-bit 256MB cache (72-bit 512MB module upgrades available); ECC protection, battery-backed, and transportable
Logical Drives SupportedUp to 32 logical drives
Maximum Logical Drive
Capacity
3 TB (6 x 500GB)
RAID Support RAID 6 with ADG (Advanced Data Guarding) requires Battery Backed Write
Cache Upgrade
RAID 5 (Distributed Data Guarding)
RAID 1+0 (Striping & Mirroring)
RAID 0 (Striping)
Smart Array E200
Controller
Disk Drive and Enclosure 3G SAS (Serial Attached SCSI)
Interface
1.5G SATA (Serial Advanced Technology Attachment)
SAS Connectors 2 internal (SFF8484) x4 wide port connectors
Cache Memory Speed DDR1-266 MHz provides up to 4.2 GB/s maximum bandwidth.
Server Interface
SAS Speed x8 2.5G PCIe provides 2GB/s maximum bandwidth.
x8 3G SAS provides 2.4GB/s maximum bandwidth.
Cache Memory 40-bit 256MB cache (72-bit 512MB module upgrades available); ECC protection, battery-backed, and transportable
Logical Drives SupportedUp to 32 logical drives
Maximum Logical Drive 3 TB (6 x 500GB)
Capacity
RAID Support RAID 6 with ADG (Advanced Data Guarding) requires Battery Backed Write
Cache Upgrade
RAID 5 (Distributed Data Guarding)
RAID 1+0 (Striping & Mirroring)
RAID 0 (Striping)
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 44
QuickSpecs
HP ProLiant ML370 Generation 5
Technical Specifications
Multifunction Gigabit
NICs
Compatibility
10Base-T/100Base-TX/1000Base-TX
IEEE 802.3 10Base-T
IEEE 802.3ab 1000Base-T
IEEE 802.3u 100Base-TX
Data Transfer Method PCI Express, four lanes (x4)
Network Transfer Rate 10Base-T (Half-Duplex) 10 Mb/s
10Base-T (Full-Duplex) 20 Mb/s
100Base-TX (Half-Duplex) 100 Mb/s
Connector
Cable Support
100Base-TX (Full-Duplex) 200 Mb/s
1000BaseTX (Half and
Full-Duplex)
2000 Mb/s
RJ-45
10Base-T
100Base-TX
Categories 3, 4 or 5 UTP; up to 328 ft (100 m)
Category 5 or higher UTP; up to 328 ft (100 m)
1000Base-TX Category 5 or higher UTP; up to 328 ft (100 m)
© Copyright 2006 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel
Corporation.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less.
DA - 12478 Worldwide QuickSpecs — Version 1 — 6/26/2006 Page 45
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement