PENTAX PCS-200 PCS-225, PCS-215 Electronic Total Station Instruction Manual
PDF
Документ
Реклама
Реклама
PENTAX"
ELECTRONIC TOTAL STATION
PCS-200 SERIES
PCS-225/PCS-215
INSTRUCTION MANUAL
ASAHI PRECISION CO., LTD.
Safety Precautions
Before using this instrument, be sure to read the following precautions
carefully. Pentax cannot be held responsible for problems which result
from failure to observe these precautions.
Г /\ WARNING! В
The following items could cause severe bodily
injury and should be observed at all times.
© Looking directly at the sun without attaching a filter to the telescope can
result in a loss of eyesight. Always use an objective filter when observing
the sun. (When observing the sun, always attach the solar filter, designed
\_ especially for this purpose by Pentax, to the objective lens.) J
/\ CAUTION
The following actions could cause serious dam-
age to the instrument.
© Never remove the hand grip carelessly. If it is detached, reattach it
securely. lf the grip is loosely or incompletely attached, the instrument
could fall and cause a serious injury to occur.
© Make sure not to short the battery terminals. If these are shorted, the
resulting high current would not only damage the battery, but could also start
a fire.
Safety Precautions
Warning!!
© If the telescope is pointed directly at the sun
without an objective lens filter attached, the
internal electronic components could be damaged
by the concentrated energy of the sun. Do not
aim the telescope at the sun without protecting it.
(When making solar observations, always use the
objective lens filter.)
C Never disassemble the instrument or the battery. If
you find a problem, please contact the dealer
where the instrument was purchased, or get in
touch with Pentax.
© lf the instrument or the battery comes in contact
with water, wipe it off as quickly as possible and
set it in a dry place for a while. When it is
completely dry, put it back in the case.
© Always turn off the power when removing the
battery from the instrument. If the battery is
removed with the power left on, the instrument
could be damaged.
© Avoid storing the instrument in locations where
the temperature or humidity is high, or places
which are exposed to direct sunlight.
|
Precautions for inspection x
When inspecting the instrument, make sure to read and observe
the "Inspection and Adjustment" items on pages 73-80 before
beginning the work.
This company is not responsible for damages due to surveying
results obtained from an instrument which has not been inspected.
N
Table of Contents
1-1. Names and Functions of Parts Cee Eee eee Eder eee em ee etre ee teen ee eee eta Era merece 6
1-2. Taking the Instrument Out of the Case rr, 8
1-3. Installing and Charging the Battery sata eea aan ato TAE Arata one oDadidiaaneannameocrocararaT. 9
2-1. Displayed Characters and MarkKs ek EEKEREKRRKRRRREK LEER EREER TER EEFKRTERREK RER FRE ERRRERREEGE 11
2.2 Sample HUSA ONS co vrei eer eee eee eee rea 12
2-3. What the Keys 0 ce ee 13
5-1 ‚ Turning the Power On and Off ema a Eee em aammvianarins eb EA ee aera ee aera 18
5.2 Setting the Vertical 0 Point Manta ad rana tea PaPRrIA EriAtrarer memory nn nararidrarenareemarartor areare APS 1 9
6-1. Measuring the Angle (in Distance Mode) «wri cc 20
6-2. Measuring the Angle (in Angle Mode) «viii ce, 21
6-3. Setting the O Point for the Horizontal Angle eee e 22
6-4. Changing the Horizontal Angle to a Left Rotation ceci 22
6-5. Retaining the Horizontal Angle (HOI) «ori, 23
6-6. Setting a Horizontal Angle of 90° «ero, 24
6-7. Percentage Display (Grade) for the Vertical Angle «vio, 25
Table of Contents
7-2. Centimeter or Millimeter Unit Measurements (Rapid Measurement) "т: 27
7-3. Displaying the Slope Distance and Height Differential еее! 28
8-1. Changing From Distance to Angle Mode UP 29
8-2. Changing From Angle to Distance Mode «oem 30
10-1. Changing the Temperature reece RP SES SES EEE TETE SEE 34
10-2. Changing the Pressure ==: eee eee eee EEG 36
10-3. Changing the Prism Constant (Numeric Key Input). 38
unctions: oe
11-1. About the Special FUnctions -……-wemeereeecee scie eee eee ee 40
11-2. Changing to Special MeasurementS 4446400400044 41
11-3. Distance Stake Out Measurement ei er 42
11-4. Offset Station Measurement ia 45
11-5. Lot Staking Measurement ……<<ercereeeeenmnnmnnn es 48
11-6. Coordinates Measurement -—-----------<…<receccreeresseaseene esse senc ces ces rade ete 50
11-7. Resection Measurement ---…...….…eceeeceeenenenennennennennnnnnennnnnnnmnnenn 52
11-8. Traverse Measurement ---……----.--.-<-<-errecreeccccecrennence re eee ce ces nee cree 54
11-9. Coordinate Stake Out Measurement --------…ececrerieneeecenreneenen center 56
11-10. Remote Distance Measurement EEE RE 58
11-11. Remote Elevation Measurement a 60
Table of Contents
12-2. Initial Settings Mode A rrr aan 61
12-3. Initial Settings MOE B rooms eee 61
12-4. Initial Settings 17/01] -R OR TT 62
12-5, Initial Settings Mode D nero naa ENArTAFEAEAre nad een ren errem ara orton Tar COR Ara rNtamiaa nennimminaraaa AEREA 64
12-6. Initial Settings Mode E CE here aE EE EEE EE EE ed Eh Ae mmm cera a yA TIENAAN aNENrAPaCR anna anadrmarmmeménnarvarma 64
12-7. Accessing Initial Settings A Pearetinracran rare cantas an ta a OE AAA Dore Bed em ame rae aera 65
12-8. Accessing Initial Settings B he Eee Ae ee anoan iaa tana O ENTRE A TAD IF ARA Gn emea men a PRATTN NA ERACEINE 66
12-9. Accessing Initial Settings C EE URG 66
12-10. Accessing Initial Settings D EEE et Et es ehh ee emer rama tra E eR Eira menramEn ONO nava yETEEAd 66
12-1 1 , Example of Changing Initial Settings ee eee EEE EA Ear orbraber rca ra rra NFAFAraNACiEAaladraróo 67
(Selecting Atmospheric Correction)
12-12. Adjusting the LCD Contrast eee sini 68
, Centering and Levelling the Instrument Less 69
, Eyepiece Adjustment and Sighting Er ere het Eat arate eee eee beet ea ties aah ae maaan renee nnn 71
. Attaching and Removing the Tribrach «is 72
14-1,
14-2.
14-3.
14-4.
14-5.
14-6.
14-7.
14-8.
Plate Vials «coco mor ren enr rea ee eee rr era taa ren errar n rotar recerca. 73
Circular I eric rare r einer acer erario rare iee errar er ere reee 74
Inclination of Reticle --- ETE TEEN 75
Perpendicularity of Line of Sight to Horizontal Axis 76
Vertical zero point BE retro TT ES Tf
Optical PIUMMET ATT 78
Offset Constant TRE 79
Beam Axis and Sighting Axis DEEE EEE PE EEE rara narco raaror ra taaa EnrmAAArANtTErOErAOFAtCAatA Aaa. 80
15-1.
15-2.
15-3.
Warning and Error Messages eee eee eee eee eur eee eee aera 81
Atmospheric Correction Naneacan rana nara taareccal ra ara rememaram ida rar Rata RO O NINO EareCaErar ron nnearaarpacro 82
hPa and mmHg Conversion Tables Les Lea 0 deep e rer re nes ea ra era n en ea sem eee eee ee ae ana sera een ANA A IAA 83
Table of Contents
15-4. Deviation When No Atmospheric Correction Is Made === 84
15-5. Atmospheric Refraction and Earth Curvature Correction" 85
15-6. Distance Range anraararecoraradranyrinarmareranermordNrrareareaimenrneersrdbN ce qranene reee treaties een. 86
17-1. MB 07 Specifications +96 siete 89
17-2. MC 04 Specifications rentree seen eee ere eee 89
17-3. HOW 10 ataCh tha MB (7 orem meets EEE 89
17-4. How to charge the MB 07 by means of MC 04 vers 89
o io
onl EA
1. Before Using Your Instrument
1-1. Names and Functions of Parts
—>9 >
Latch button
On-Board Battery
Focusing knob
Eyepiece lens
Telescope tangent screw
Telescope clamp screw
Plate vial
Plate vial
Display panel
Power supply switch
Keyboard
Clamp screw
LS
Date out connector О
Fa) Tangent screw
Co]
ibrach
Externa! NN Tribrach locking lever
Battery connector ES E
mms -
IY = leveling screw
——].];;——————
Circular vial
Bottom plate
PCS-225 (Tribrach Detachable/Display:Dual)
Before Using Your Instrument
Top handle
Collimator
Objective lens N
Um gf =
: i 1
Bottom plate | UN TT
in нд
——]—Ñ—;
PCS-215 (Tribrach Fixed/Dispiay:Single)
Data out connector
Optical plummet
Leveling screw
Before Using Your Instrument ‘
1-2. Taking the Instrument Out and Putting it Back
in the Case
Taking the Instrument Out of the Case
1. Set the case down gently, with the lid facing upwards.
2. Remove the latch while pressing down on the lock
(this is a safety device), and open the lid of the case.
3. Take the instrument out of the case.
Storing the Instrument in the Case
1. Make sure the telescope is fairly level,
and lightly tighten the lock screw that
secure it in place.
2. Line up the housing marks (round yellow
marks on the instrument), and tighten
the horizontal lock screw that secure it in
place.
3. With the housing marks facing forward,
set the instrument gently in the case, not
applying excessive force. ,
4. Close the lid of the case and set the @
clasp.
Lock
(safety device)
Latch
Housing marks
Before Using Your Instrument
1-3. Installing and Charging the Battery
Removing the battery
Always turn off the power when removing the battery from
the instrument. If the battery is removed with the power left
on, the instrument could be damaged.
Pressing down on the latch button at
the top of the battery, remove the
battery from the instrument. On-Board
Installing the battery
Insert the lower end of the battery in
the groove of the side cover and push
the top of the battery into the side
cover until you hear a click.
Amount of charge left in battery
When the power to the instrument is
turned on, a battery icon " Ë " is
displayed at the right of the display
panel so that the amount of charge left
in the battery can be checked.
zum : The instrument can be used for quite a while before the battery
runs down.
Ef e nee A spare battery should be prepared.
The battery should be replaced very soon.
Change the battery The "Change battery" display will turn off about 5 seconds after it is
displayed. Replace the battery with a spare, or charge the battery.
Before Using Your Instrument
Charging
1.Insert the quick charger (MC04) plug into
an ordinary walt socket.
2.When the charger is connected to the battery
which has been removed from the
instrument(using the connectors provided for
the charger and the battery), the pilot lamp
on the charger blinks and charging begins.
3.About 1.5 hours later the pilot lamp will stop
blinking, indicating that the battery is
completely charged.
4.After charging, remove the charger plug
from the AC power supply and disconnect
the charger from the battery.
Precautions when charging
Display panel
complete.
(OThe battery should be charged at room temperature, within a range of +07T to +457.
If charging is done outside of this regulation range, problems could occur.
(If the pilot lamp does not blink even though the charger is connected to the battery,
there may be something wrong with either the charger or the battery.
(Even though a protective circuit to prevent overcharging is built into the quick charger
(MC04), do not leave the charger plugged into the outlet for a long time after charging is
Precautions regarding storage
could be considerably shortened.
The battery should be charged at least once a month!
CA rechargeable battery can normally be charged repeatedly, from 300 to 500 times.
However, if a battery is stored in fully discharged condition, the useful life of the battery
Cn order to ensure that a battery can be used for a long time, it should be charged at
least once a month. The battery should always be charged just before it is used.
Cif the battery capacity has dropped considerably because it has not been used for a
long time, it has been affected by the storage temperature, or for other reasons, one
charging might not be sufficient to fully charge it.If this happens, the battery shouid be
alternately charged and discharged 3 or 4 times before being used.
10
2. Displays and Keybord
2-1. Displayed Characters and Marks
Character/Mark Description
+ mark (asterisk) |
' This is displayed during measurement, while the
instrument is receiving reflected beam from the prism.
SHOT
This shows that shot measurement (one time or several
times) is being used rather than the normal continuous
distance measurement.
—-ICOO COEL
_1G60Occgasol
Dot matrix
This displays distance or angle data and guide
messages in a dot matrix of two rows of 12 characters.
P-30
When the prism constant is set to "— 30mm", [P-30] is
displayed; when the prism constant is "0", [P-0] is
Ocpm
displayed.
This is displayed when the standard temperature of 15 C and air
pressure of 1013 hPa have been set, or when "no correction” has
been selected. When changed to anything other than the standard
temperature or air pressure setting, the display disappears.
[
MI
This indicates how much charge is left in the battery. The
black area changes to white in three stages as the
battery capacity decreases (see page 9).
In
нечто mm
During measurement, a 4mark indicates the horizontal
distance, indicates the slope distance, and dshows the
height differential (or the height).
11
2-2. Sample Illustrations
The keyboard illustrations provided in this manual have been simplified so that
they include only those portions which illustrate the point currently being
discussed.
Actual diagram
— TTT
Of >>
| y 1 29.415m 5 onorr|
| H. ANG 60 °30'20" Е ()
| м. |н.ноко| oser | a | woe
< [> V А e O;
DD COCO GT DD Q
o
Simplified diagram
In these illustrations, the finger shows which key should be pressed.
This means to press the This means to press the
PRM.PSM
> still sounding.
This means to press the
A picture of two fingers means to press the same key twice. Also,
the 4 picture means that if the key is pressed only once a buzzer
Fi” . , .
— E é | will sound, and the key should be pressed again while the buzzer is
Displays and Keyboard
2-3. What the Keys do
The various keys have several functions, as shown below.
RIL | H-HOLD | OSET | MODE
Cone key: This selects the desired mode.
key: This changes the display in sequential order from horizontal
distance to slope distance to height differential.
— 0 SET key: This sets the horizontal angle to 0.
H-HOLDkey: This key holds the horizontal angle shown on the display.
R/L —key:This switches between left and right rotation of the horizontal
angle.
S. FUNC | PPM.PSM ANG-% | ТВК | OK
<] [> Y A I
| _OK key: This initiates the measurement.
| TRK key: This initiates rapid measurement.
ANG" % key: This switches to angle mode.
PPM.PSM :This switches between the temperature, pressure, and
key prism constant input screens.
S.FUNC key: This switches to the special measurement modes.
13
Displays and Keyboard
Key Functions During Measuring Operation
Key
Function
ON/OFF
ON/OFF key: This turns the power on and off alternately.
IV E Y A ©
IO 5
ILLUMINATION key:This turns the lighting on and off
for the LCD panel and the telescope reticle.
<] [= Y А o
IO OD OD
R/L key:Pressing this key switches between left and
right rotation of the horizontal angle.
H- HOLD key:Pressing this key twice retains (holds) the
horizontal angle shown on the display.
O SET key:Pressing this key twice sets the horizontal
angle to 07 00'00".
-d key:Each press of this key changes the distance
display in sequential order from slope distance to height
differential to horizontal distance. In angle mode,
pressing the key changes to distance mode.
OK key:Pressing this key terminates the numeric or
selection input and advances to the next screen.
| Displays and Keyboard
Key Functions During Measuring Operation
к ey |
Function
MODE key:Pressing this key selects modes such as a
special mode or a correction mode.
S. FUNC key:This is used to select the special function modes
(distance stake out, lot staking, offset point, remote elevation,
remote distance, coordinates, resection, traverse,and
coordinate stake out measurements).
PPM.PSM
fe
Ce
0
(>
Do
PPM:PSM key:This enters the mode where the
temperature, pressure, and prism constant can be
corrected.
ANG -% key: This switches between distance and angle
modes. In angle mode, the vertical angle is displayed as
a percentage.
TRK key:This switches between normal measurement (a measurement
time of approximately 2.0 seconds, with display in mm) and rapid
measurement (a measurement time of approximately 0.5 seconds in
centimeters or 0.8 seconds in millimeters).
ESC key:This returns from the various modes to the
normal measurement mode.
When a special measurement mode has been
accessed, pressing the Y or 4 key displays the items
pertinent to that mode in sequential order.
15
Displays and Keyboard
Key Functions During figure input
Key Function
Pressing the € key moves the blinking cursor to the
left., and pressing the } key moves the blinking cursor
to the right.
Each time the ¥ key is pressed, the blinking numeric
value decreases by 1.
Each time the 4 key is pressed, the value increases by
1.
3. Setting Measurement Conditions
With this instrument, a number of conditions such as the prism constant and
atmospheric correction method can be specified in advance. The user can
change the original settings, entered when the instrument is shipped, which are
referred to as "initial settings”. Please see the section on page 61 entitled "Initial
Settings" for more information on these settings.
16
4. Operation Flowchart
The illustration on this page shows the general flow of operations with this instrument.
Set vertical O point
| Shot measurement
|
Continuous measurement
1
Quick-shot Quick-shol
ON OFF Vania
/L H-HOLDÍ O SET | = | ESC
> Y A с
<
RL H-HOLD| 0 SET | « |MODE
a > vo oa 9°
Ges
S. FUNC| PPM: PSM | ANG -%| TRK| OK
<] [> / A 7)
* When the instrument is shipped from the factory, the quick-shot measurement function is
set to ON (the number of measurements is 1). This can be changed in the initial settings if
desired.
17
5. Turning On the Power
5-1. Turning the Power On and Off
A v ANG TT
V. ANG
Power supply key
Hans - PCS-series- =
S. FUNC |PPM.PSM ANG. %
R/L H HOLD| 0SET
PENTAX -- 6
TRK OK ESC
| MODE
After approx. 2 seconds +
ON
DD OIGA DI I H. ANG 85°50'20' =
Pressing the ON/OFF key causes all A |н-носс | 0 SET | |
TURN SCOPE
display segments to light.
After approximately 2 seconds horizontal be initiated.
angle measurement is initiated.
(To turn off the power press the an/off key
once again) (Right page)
@For any measurement other than horizontal angle measurement, the vertical angle index
point should be specified.
@When the power is turned off, the horizontal angle displayed
that when the power is turned on again, that horizontal angle
horizontal angle is no longer necessary, set it back to 0.
@With the auto power off function, the power is turned off automatically if a period of
approximately 10 minutes elapses without any operation.
Horizontal angle (right rotation angle) can
Proceed with setting of Vertical Q point.
4
at that point is retained, so
is displayed. If the previous
To change to left rotation angle of the horizontal angle
To retain (hold) the horizontal angle oi
To set the horizontal angle to Q ve,
For information on the auto power off function ++
ВИ See page 23
paresse sans ne See page 22
verre See page 64
UTR See page 22
18
Turning On the Power
5-2. Setting the Vertical 0 Point
Display
Operation Procedure |
Horizontal Distance symbol.
position |
| Prism constant is — 30mm
TT
P-30
, es Moppm
After the power is turned on, turning the H. ANG 85°39 40" =
. ESC
telescope up and down and passing through RIL IH. HOLD О БЕТ | р |
the horizontal position sets the O point for the
vertical angle and displays a distance mark
4 in the display section. The vertical angle
and distance can now be measured.
O Horizontal angle measurement can be done even if the O point for the vertical angle
has not been set.
@The horizontal angle displayed, when the power is turned on, is that which was displayed
when the power was last turned off. If the previous horizontal angle is no longer necessary,
set it back to 0.
@In some cases, distance measurement can be carried out even if the O point for the
vertical angle has not been set. (This occurs when the telescope passes through the origin
point as the horizontal angle is being measured.)
To change to left rotation angle of the horizontal angle se See page 22
To set the horizontal angle to O 00000 rer See page 22
To measure the vertical angle See pages 20 and 21
To measure a distance EEE EEK EEE EEE See page 26
19
6. Angle Measurements
6-1. Measuring Hl the € Angle in E Distance Mode)
“Display -
1 (This step should be carried out after
the O point of the vertical angle has
been specified.) ¡Mark for Distance mode
a Mopar
— 1 Il =
OSET ÉS HANG О ° 0 О 0 0 El
a= 2 ESC
С © H.HOLD Q SET |
After sighting the first target, press [0 SET]
twice and set the horizontal angle.
4 má?
Sight the second target and read = i | a =
the horizontal angle. HANG 6030 20 E
ESC
RIL |H HoLD| 0 SET | |
À Moppr
ANG 87°05'40" Е
ESC
2 | | a
; Press the key to disply the vertical angle.
Of only the horizontal angle is being measured, the vertical angle O point does not have to
be specified.
O The [0 SET] key cannot be used to set the vertical angle to O.
Of the power is turned off during a measurement, the horizontal angle effective at that point
is retained, so that when the power is turned on again, that horizontal angle is restored.
@ If the restored horizontal angle is no longer necessary, set it back to 0.
To set the уегИса! апа!е 1 ех рой пелеееееенееенененнееннеенеоо) See page 19
To set the horizontal angle to 0 sr. Lana aware tés EEE A EE Ae kde hee meee enemas See page 20
20
‘Angle Measurement
6-2. Measuring the Angle (in Angle Mode)
This is done after the mode has been changed from the distance mode to
the angle mode, as described on page 29.
_ Operation’ Procedure ES Display
os {X V. ANG 90°46 20”
4 ANG 100°00'00" Е
= = = = N
fi RL H. HOLD, 0 RET | ' MODE
After sighting the first target, press [0 SET] No set for H.angle
twice to set the horizontal angle.
2 V. ANG 87°15'40"
Sight the second target, and read the ANO 34%47'20" El
Vertical angle and the horizontal angle. an H LoLD| oser | MODE
@The [0 SET] key cannot be used to set the vertical angle to 0.
@ li the power is turned off during a measurement, the horizontal angle effective at that point
is retained, so that when the power is turned on again, that horizontal angle is restored.
@ If the restored horizontal angle is no longer necessary, set it back to O.
On angle mode, the vertical and horizontal angles are displayed at the same time.
To set the horizontal angle to 0 anaianimarerenrr Ar ANTArAT Em nan erren aan harearerrene arremete See page 22
21
Angle Measurement
6-3. Setting the 0 Point for the Horizontal Angle
P-30
A Moppm
H. ANG 0°00'00" =
ESC
Press the [0 SET] key twice to set the RL H HOLD) OSET— fl |
horizontal angle to 0°00'00". |
@ Only the horizontal angle can be set using the [0 SET] key.
@ The horizontal angle can be set to 0 at any point except when a hold is in effect.
@If the [0 SET] key is pressed by mistake during a measurement, the angle will not be reset
to 0 unless the key is pressed twice. The only thing that happens is that a buzzer sounds,
and when the buzzer stops, operation advances to the next step.
6-4. Changing the Horizontal Angle to Left Rotation
Minus mark
A a
us Hang E2 9929 ' 40" E
| ESC
Pressing the [R/L] key sets the horizontal RL H. HOLD| 0 SET ” |
angle to the opposite rotation of its
current setting.
O The [R/L] key can only be used to switch the horizontal angle.
@To return from a left rotation to a right rotation angle, press the [R/L] key.
@ When the rotation is switched to the left rotation, the order in which targets are sighted also
switches to the opposite order of that for right rotation (sighting moves from the righth and
target to the lefthand target).
22
Angle Measurement
6-5. Retaining the Horizontal Angle (Hold)
Display
tr eae]
Operation Procedure
M + ]
| H HOLD &
a+ А >.30
D Mm < > A Moppm
uns 130°45'20" Е
To hold the displayed value (the horizontal HL HOLD | |
angle), press the [H- HOLD] key twice in
succession. The horizontal angle is fixed
at the present value.
O The [H- HOLD] key cannot be used to hold the vertical angle or the distance.
O To cancel a hold, press the [H- HOLD] key once.
Of the [H-HOLD] key is pressed by mistake during a measurement, the hold will not
be initiated unless the key is pressed twice. The only thing that happens is that a
buzzer sounds, and when the buzzer stops, operation advances to the next step.
23
Angle Measurement
озет 25
<1 > Tv “A © 4 Mopar
IO QRO 5 | =
4 ANG 0°00'00 "Е
ESC
RL [H.HOLD. OSET |
After the first target has been sighted,
press the [0 SET] key twice to set the
horizontal angle to O.
2 P-30
. 4 Moppm
Rotate the instrument in the 90 setting LANG 89°59'20" E
direction and stop when the 90° buzzer ESC
|н. HOLD] 0 SET | |
sounds.
3
P-30
Use the horizontal tangent screw to set | 4 Moppm
the angle to 90°00'00" and then mark the H ANG 90°00'00"
ESC
point, sighted with the telescope, as the RIL Mm HOLD | OSET — | |
setting point.
O The 90" buzzer sounds each time the horizontal angle is within 1' on either side of the 0”,
90°, 180" and 270° points and stops when the angle reaches 20" before or after that
point.
@The initial setting for the 20° buzzer can be set to "OFF".
To turn the 90 buzzer on and off oe me See page 64 :
24
Angle Measurement a
6-7. Percentage Display (Grade) for the Vertical Angle
The vertical angle percentage (grade) can be displayed after the mode has been
changed from the distance mode to the angle mode, as described on page 29.
in Operation Procedure —. Display
SELECT MODE
ESC
ANG. %
Use the [MODE] key to select the mode.
A minus sign (— ) indicates a downward slope.
ANG.% ESC
< > Y А
So ар Оба -1.02%
ESC key mano 359°59'40" E
ESC
Use the [ANG-%] key to display the an | vow) oser |
percentage for the vertical angle.
a downward slope.
@ With the percentage display, the horizon is indicated by 0%, and 45° upward and
downward of the horizon is indicated as 100%.
O To return from a percentage display to a 360° scale, press the [ENT] key.
Of the percentage display exceeds + 100% (+45), the message "EXCESS ANG." is
displayed, and measurement is not possible.
O The "EXCESS ANG" message disappears automatically when the telescope returns within
the100% range.
For the height differential (percentage display) of the distance тео: See page 28
25
7. Distance Measurements
7-1. Millimeter Unit Measurements (Normal Measurement)
Display
/ Mark for Distance mode
1 If the display is in the angle mode, A P-30
. E ИП Opom
change it to the distance mode. (For . = , o
instructions on changing to the - 34 28 40 Е
distance mode, see page 30.) RIL m HOLD | 0 БЕТ «а MODE
PUSH OK MEAS opm
MODE Oppm
I в Y A G =
O O OS a PPM =
S. FUNG | PSM | ANG. % | TRK | OK
Sight the prism with the telescope, and
press the [MODE] key.
3 и песемпо mark of reflected beam
Ge P-30
Aa Opam
< > v
oOo a 34%28'40" E
ESC
R/L H HOLD, O SET | ai |
Press [OK]key to start the distance : +
measurement. When the beam reflected : Shot Number
from the prism reaches the instrument, a
buzzer sounds, and the [+ ] mark is , А P.30
displayed. Shot measurement begins я NT 53.378mMom
automatically.(For information on slope | H. ANG 34%28'40" E
distance and height differential displays, AIL H HOLD! о ВЕТ 4 | MODE
see Horizontal distance: see page 28.)
@ If the Quick Shot function is set to "YES", the distance will be displayed for the first measurement simply by
sighting the prism. (Starting with the second measurement, the [MODE] key has to be pressed.)
Of "Continuous Measurement" has been specified in the initial settings, the distance will be displayed simply
by sighting the prism.
O To measure distances, the 0 point of the vertical angle has to be specified after the power has been turned on.
O Always confirm the constant for the prism being used (see page 38 for instructions on changing the prism
constant).
O The following marks are displayed in the distance mode: horizontal distance 4, slope distance 4, and
height differential 4.
26
Distance Measurements
7-2. Centimeter or Millimeter Unit Measurements
(Rapid Measurement)
5 Operation Procedure
1
Change the display to the distance mode.
(For instructions on changing to the
distance mode, see page 30.)
/ Mark for distance mode
7
\
P-30
M oppm
34 °28 ' 40" Е
RIL H. HOLD | 0SET | dl | MODE
—
=
—
H. ANG
Select the mode by pressing the [MCDE]
key.
PUSH OK MEAS И
PPM.
S. FUNC | PSM | ANG. % | TRK OK
|
Waiting for mode selection.
3
<]
—
0
7
<= >
OC CD
Use the [TRK] key to initiate rapid
measurement. Following this,measurement
will be repeated approximately every 0.5
seconds for centimeter distances and every
0.8 seconds for millimeter distances.
y 53.37mom
НАМ 34 °28 ' 40" Е
| ESC
ВА. |H. HoLD| O SET a |
@ The slope distance and the height differential can be displayed during rapid measurement
by pressing the 4 key.
O To return to the normal measurement mode, press the [ENTER] key.
O For information on selecting the minimum distance display unit for rapid measurement, see
"Initial Settings Mode B" on page 62.
27
Distance Measurement
7-3. Displaying the Slope Distance and Height Differential
— Operation Procedure Display —
1 / Mark for the slope distance
4
À 87 . 655 moe
A, Mopem
Y. ANG 87°05'40" E
Press the key while the horizontal | | | dl | MCDE
distance is displayed to change the
display to the slope distance. Displaying the slope distance and vertical angle
2 = | / Mark for the Height Differential
4 |
~~ P-30
al) 4 . 4 4 3 Moppm
Le 5.07 % Е
Press the .« key while the slope distance RIL H HOLD 0 SET | р” | MODE
is displayed to change the display to the
height differential. Displaying the height and differential and percentage
3 / Mark for Horizontal distance
4 /
/
À — |
ae e 2 87 . 65 5Moppm
COCO TOO Tp CD Y, ANG I = -
I 60°30'20" El
Press the A key while the height ВА HL HOLD CSET — MODE
differential is displayed to change back to | Displaying the horizontal distance and horizontal angle
the horizontal distance display.
OEach time the . key is pressed, the display changes sequentially in the following order:
[horizontal distance] — [slope distance] -- [height differential] — [horizontal distance]. (The
sequence can be changed to the following in the initial settings: [horizontal distance] — [height
differential] — [slope distance] — [horizontal distance]. See page 63 for instructions.)
@ Displays are shown in combination, as follows: horizontal distance + horizontal angle, slope distance
— vertical angle, height differential + % grade. (The combinations can be changed using the initial
settings.See page 63 for instructions.)
Combinations
— Horizontal angle -— Horizontal angle — Horizontal angle
Slope Horizontal Height
distance vertical angle distance — Vertical angle differential — Vertical angle
— Grade (%) — Grade (%) — Grade (%)
28
8. Changing the Measurement Mode
8-1. Changing From Distance to Angle | Mode
‘Operation Procedure
MODE
<1 V
OÍ
Press the [MODE] key to select the mode.
PUSH OK MEAS fom
PPM.
S. FUNG | PSM | ANG. % OK
Waiting for mode selection.
2
Press the [ANG 9%] key to change to the
angle mode.
90°46' 20"
63°25' 40" Е
uu
LE oo] oser |
V. / angle and H.Angle are displayed at a
a V. ANG
| MODE
same time in Angle mode.
O The angle can be measured in the distance mode, but the distance cannot be measured
in the angle mode,
O When the power is turned on, the mode will always be that selected in the initial settings.
To measure an angle enmineroorcarenro aten amsn a nana en
To measure a distance Lea a ae ae aa em a ae na
For initial settings Lara dar a race are sera Recent A ae ae ae
RE See pages 20 and 21
ee a aa ERBE a aa a ae aa aa de a ea a à See page 26
RAIN re SOE page 61
29
Changing the Measurement Mode
8-2. Changing From Angle to Distance Mode
SELECT MODE
| | ANG. % ESC
Press the [MODE] key to select the mode. Waiting for mode selection
2 . | Mark for distance mode
,
| a | 7 P-30
_—9 E _V A O. N—
ES HANG 63°25'40" E
im ESC
R/L A HOLD| O SET a |
Press the A key to change to the distance mode.
@The angle can be measured in the distance mode, but the distance cannot be measured
in the angle mode.
O When the power is turned on, the mode will always be that selected in the initial settings.
To measure an angle A, See pages 20 and 21
To measure a distance ecinanasrcioaae aria rrarareariarercarieracior re imareere rear rveraarm cara trate. See page 26
For initial settings A See page 61
30
9. Selecting the Mode
9-1. Pressing the [MODE] Key (in Distance Mode)
In distance mode, the following four modes can be selected:
1. Special function mode --- Measurement can be carried out using the nine types of
special surveying software noted on page 40.
2. Correction mode ------------- The temperature, atmospheric pressure,and prism constant
can be confirmed, and settings entered or changed.
3. Angle measurement / % mode --- This changes to the angle mode.
4. Rapid measurement mode --- Measurement is carried out at a fast speed of approximately 0.5
seconds in centimeter and 0.8 second in millimeter units.
ion
Procedure | | ) | Display
4
|
A
| MODE PUSH OK MEAS”*
EC =
< > y
D >) CO) CO CO Gp PPM =
1 S. FUNC PSM | ANG. % TRK OK
Press the [MODE] key to select the mode.
2 — —
El SPEC. FUNC.
SELECT BYY E
| | ESC
Dels
Press the [S. FUNC] key to access the special
measurement selection mode. (For information on
the special measurement modes, see page 41.)
Ат № МНН 8 МНН = = = ны № ны eee see Emm Em ees ae Em OS — = "= au = = тонны в ны с ас = DD DD Er UD косе = ож с ==. —
| PPM.FSM OK
o
TEMP: +15°C
PRES: 1013hpa [g
| OK
<= [= Y А
Press the [PPM- PSM] key to display the
temperature, atmospheric pressure, and prism | The temperature and atmospheric pressure
constant. (For information on changing the which were previously entered are displayed.
temperature, atmospheric pressure, and prism
constant, please see pages 34 to 39.)
(Cont. on next page)
31
Selecting the Mode
ANG.
AZ DES М. АМС 8921 40"
pe 127°40'20" E
Press the [ANG -%] key to change to the АЕ H HOLD. O SET | MODE
angle mode. (For information on changing
to the angle mode, see page 29.)
|
= 7 53.37 mm
Use the [TRK] key to switch to the rapid ANG 34%28'40" E
measurement mode, in which measurement | ESC
RL |H. HOLD SET | A
is carried out at a fast sreed of approximately
0.8 seconds in millimeter units. (For
information on the rapid mode, see page 27.)
O Pressing the [ESC] key returns the screen to the status it was in before the mode was
entered.
32
Selecting the Mode
9-2. Pressing the [MODE] Key (in Angle Mode)
This is done after switching from the distance mode to the angle mode, as
described on page 29.
MODE SELECT MODE
<] > Y A
ooo Oo
w | | ANG. % |
Press the [MODE] key to select the mode.
ANG.% _ 1.02%
< > Y A Oo
= = =< H. ANG 359°54'40" E
fn ESC
RL H HOLD, 0 SET |
Using the [ANG %] key, display the
percentage of the vertical angle.
P-30
MM ESC A Opp
< > v А C no [=
© © © с CO H. ANG 359759 40 =
fr ESC
HH. HOLD 0 SET | aa
Use the [M4] key to change to the
distance mode.
Pressing the [ESC] key returns the screen to the status it was in before the [MODE] key was
pressed.
33
10. Correction Mode
10-1. Changing the Temperature
The temperature can only be changed when "Enter" is selected under"PPM
CORR" of "Initial Settings A".
PUSH OK MEAS&®
PPM.
6 РОКС | PSM | ANG- % TRK | ©
Waiting for mode selection
2
Press the [PPM-PSM] key to display the
temperature and atmospheric pressure which
have already been entered. (The temperature
is flashing.)
Flashing
TEMP: +1 ]°c
PRES:1013hpaß®
UT
3
OThe numeric value for the temperature
which is flashing can be changed.
OPress the right [SHIFT] key to move the
flashing numeral to the right, and the left
[SHIFT] key to move it to the left.
Flashing left shift key
NE E V A ©
= Doc
Flashing right shift key
4
To change the flashing value, use the [+] and
[—] keys to increase or decrease the value.
Each time the key is pressed once, the value
changes 9y 1 in the corresponding direction.
Numeric minus key
A
< E M E с
Numeric plus key
5
Use the [SHIFT] key to move the flashing
display to the value to be changed, and
press the [+ ] or [— ] key to change to the
desired value.
Changed Temperature
34
>
TEMP: +22%C€
PRES:1013hpa El
| | |“
Correction Mode
TEMP: +22°C
PRES:1013hpa =
OK
IE A 0 OK
N Waiting for new pressure input (See page
Press the [OK] key to input the updated | 36 for instructions on changing the
temperature. The flashing display moves | pressure)
to the atmospheric pressure value.
O The range of values which can be input for the temperature is from — 30'C to + 60C.
Of the atmospheric pressure does not need to be changed, press the [OK] button to move to
the prism constant. If no change is necessary here, either, press the [OK] key again to
move back to the measurement mode.
@The input temperature is retained when the power is turned off.
O The standard temperature correction is 15°C.
Gif "PPM FIXED" is displayed, the atmospheric correction function has been turned off in
the initial settings,and the temperature and pressure cannot be changed.
If the instrument is used without correcting the temperature, the error will
be approximately — 0.1 mm per 100 m for each + 1C that the temperature
is off from the standard value of 15°C, and will be approximately 3.1 mm per
100 mat — 1 C. (For precise figures, see page 84.)
35
10-2. Changing the Pressure
The atmospheric pressure should be changed after the temperature has been
changed.
Press the [MODE] key to select the mode.
2
PPM.PSM
Press the [PPM- PSM] key to display the
PUSH OK MEASI%
PPM.
S. FUNC PSM ANG. %
TRK OK
Waiting for mode selection
/ Flashing
/
TEMP: Holz °C
PRES: 1013hpa =
3
Press the [OK] key to move the flashing
display to the pressure value.
4
The numeric value for the pressure which is
flashing can be changed.
@Press the right [SHIFT] key to move the
flashing numeral to the right, and the left
[SHIFT] key to move it to the left.
OK
temperature and atmospheric pressure which have | | | |
already been entered. (The temperature is flashing.)
Flashing
TEMP +22°C
PRES: 1013hpa El
OR
Flashing left shift key
NA > VA 0
98-07
Flashing right shift key
5
To change the flashing value, use the [+] and
[—] keys 10 increase or decrease the value.
Each time the key is pressed once, the value
changes by 1 in the corresponding direction.
Numeric minus key
|
< NE A ©
Numeric plus key
36
Correction Mode
6
Use the [SHIFT] key to move the flashing
display to the value to be changed, and PRES: 985hpa =
press the [+] or [—] key to change to the | | OK
TEMP: +22°C
desired value.
= -
PPM
= 14ppm Е
pie | OK
Press the [OK] key to enter the new value
and display the "ppm value”.
SET PRSM
= ; о O —30 —30mm. =
> Y
< © © © | | | | OK
Press the [OK] key to change the "Prism Waiting for prism constant to be changed
Setting" screen. (see page 38 for instructions)
O The input range for the atmospheric pressure is from 600 hPa to 1120 hPa (420 mmHg to
840 mmHg).
Of the prism constant does not need to be changed, press the [OK] key to return to the
normal measurement mode.
O The input pressure value is retained when the power is turned off.
O The standard value for the atmospheric pressure correction is 1013 hPa.
|
If the instrument is used without correcting the pressure, the error will be
approximately —0.3 mm per 100 m for each — 10 hPa that the pressure is
off from the standard vaiue of 1013 hPa. (For precise figures, see page 84.)
37
Correction Mode
10-3. Changing the Prism Constant (Numeric Key Input)
Changes to the prism constant can be made only when "Enter" has been
specified in the initial settings.
peration Procedure Display
Press the [MODE] key to select the mode selection.
PUSH OK MEAS"”%
=
PPM.
S FUNC PSM ANG. % TRK | OK
Waiting for mode selection.
2
PPM.PSM
Press the [PPM-PSM] key to display the
temperature and atmospheric pressure
which have already been entered.
/ Flashing
TEMP: {is °C
PRES:1013hpa Е
|1 |1”
3
Press the [OK] key twice to move the flashing
display to the pressure value ("Prism Setting").
SET PRSM
0 —30 —3jomm.
NA
N
“Flashing
4 The numeric value for the prism constant |
which is flashing can be changed. Press
the right [SHIFT] key to move the flashing
numeral to the right, and the left [SHIFT]
key to move it to the left.
Flashing left shift key
а в У Ао
3 aa
Flashing right shift key
5 To change the flashing value, use the
[+ ] and [—] keys to increase or
decrease the value: Each time the key
is pressed once, the value changes by
1 in the corresponding direction,
Numeric minus key
Об РМО А O
Numeric plus key
38
Correction Mode
“Operation Procedure Display
6
Use the [SHIFT] key to move the flashing SET PRSM
display to the value to be changed, and 0 —30 25 mm. E
press the [+] or [—] key to change to the | | OK
desired value.
7 |
m
34°28'40" =
RIL HOLD | osET | a | MODE
In
Press the [OK] key to enter the new value
and return to the measurement mode.
@® To set the prism constant to "0" or '— 30", the "— 30" and "0" values displayed in the
display section, in addition to the other settings entered using the above keys, can be set
to flashing and the "OK" button pressed to select those constants.
Of "— 30" or "0" has been selected for the prism constant, or "— 30" or "0" has been entered
using key input, the indication "P-30" or "P-0" is displayed at the right end of the display.
Of any setting other than "— 30" or "0" has been entered for the prism constant using key
input, nothing will appear in the display section.
O When the instrument is shipped from the factory, "— 30" has been entered using key input.
O The input value for the prism constant is retained when the power is turned off.
Of "Prism Fixed" is displayed, a fixed prism constant has been selected in the initial
settings, and the value cannot be changed using key input. Change the parameter in the
initial settings to "Enter" to change the value.
39
11. Special Functions
11-1. About the Special Functions
This instrument is equipped with nine types of special surveying programs, making it extremely simple
to carry out the various types of measurement.
O Distance Stake Out measurement
By inputting the distance to be determined by the machine, thedifference between that
distance and the actual measured value is displayed, for extremely fast distance
measurements.
© Lot Staking measurement
The input distances from the designs, or the measured distance, can be divided into N
equal sections, and the separate sections measured.
© Offset Point measurement
This function enables the widths to the right and left of a center line to be measured
easily, by setting an PCS on the center line. {This can only be used for linear
measurements, not on curves.)
© Remote Elevation measurement (REM)
A prism (base point) positioned almost directly underneath the desired location is
measured, to determine the height to the target object. This makes it easy to
determine the heights of objects such as power cables, bridge suspension cables and
large construction objects.
© Remote Distance measurement (RDM)
This function is used to measure the horizontal distance, height differential, slope
distance, and percentage grade between two prisms set at the base point and the
various measurement points.
O Coordinates measurement
This enables the coordinates of a target point to be determined, using the instrument
point as an origin point. Even without using the instrument point as an origin point, the
coordinates of the instrument point can be input and used to determine the coordinate
values of the target paint.
©O Resection measurement
Two known points (A and B) can be measured to determine the instrument point
coordinates.
O Traverse measurement
Based on given "instrument point coordinates and backsight coordinates” or on
"instrument point coordinates and directional angle", the coordinates of a new point
can be determined.
40
© Coordinate stake out
Based on given "instrument point coordinates, backsight coordinates, and measurement point
coordinates” or on “instrument point coordinates, directional angle of the backsight point, and
measurement point coordinates’, three-dimensional coordinate stake out can be carried out.
11-2. Changing to Special Measurements
ой ‘Operation Procedure | | N Display
d
7 PUSH OK MEAS”*
MODE
Ч в У А € =
II S. FUNG PSM ANG. % OK
In distance mode, use the [MODE] key to Waiting for the mode
select the mode. key to select the mode.
2
E SPEC. FUNC. _
= SELECT BYY E
5. FUNC | | | ESC
Press the [S. FUNC] key to select a 4 | Waiting for a special
special function, function to be свеса |
3 | Display Sequence |
| STAKE out |
A key [ кот STAKING |
/
7 [ OFFSET STA. |
/ т
E SR 55 |
Press the Y or 4 key to display the desired LE coor MEAS _
measurement item. | Г RESEG MEAS
J
TRAV MEAS
— (
41
Special Functions
11-3. Distance Stake Out Measurement
By inputting the distance to be determined in advance, the difference between
that distance and the actual measured distance can be displayed. (The input
range for the distance is 0.855 mm - 1999.999 mm, and for the height differential
is — 1999.999 m - 1999.999 m.)
Comparison with design
sa
ga
y Deviation
Elevation
measured
value
|
AT
y “à Deviation
|
ze.
>
Horizontal distance measured value
42
>pecia Functions
pe eration Procedure
1
Select the special function, using the SPEC. FUNC.
ial function, usi =
procedure described on page 41. SELECT BYY E
S. FUNC | ESC
STAKE OUT
< [= W A с =
OO OO Е
5. FUNC | | | OK
Pressing the Y key displays the"Distance
Stake Out" item.
4 SET .DISTANCE™™
AN 9990 000mE
NO |
So
Press the [OK] key. The system waits for
the distance to be input.
4 | EX: Set distance = 123.456m
4 SET .DISTANCE””
4) 0[0j00. 000m =
< > \ А J
> ooo A | | oF
# >
Flashing 4 mark, press the Y key and
then mark 4 changes to be 4, 4 and 4
in sequence.
Press the p key to move the flashing
display to the right. (Pressing the 4 key
moves the flashing display to the left.)
43
Special Functions
Pressing the 4 key increases the flashing digit
by one each time the key is pressed. {Pressing
the ¥ key decreases the flashing digit by one.)
6
La BP vá.
CoO OC CO
In the same way, use the p key to move the
flashing display and the À key to change the
value, until the desired distance has been set.
(The dand Y keys can also be used.)
4 SET.DIST 739
4 0100.000mE
| al”
y SET.DIST 0
4 0123.456mE
|| |“
7
OK
м А D
<] [=
oOo oO
When the desired distance has been input,
press the [OK] key to terminate the setting
process. When the prism is sighted, rapid
measurement begins {in centimeter units).
Move the prism until the value reads 0.00 m.
y SO 123.456m”*
=
5. NS | THK | OK
After a few seconds 4
A SO 123.456m”
-2.50 mE
5. NS | TREK | OK
O The distance displayed with the distance stake out function is the difference between the
distance to be determined (the set distance) and the actual measured distance. (A
negative value is displayed if the actual distance is shorter than the set distance.)
O With the distance stake out function, measurement is carried out automatically at high
speed. Pressing the [TRK] key switches alternately between normal and rapid
measurement speed each time the key is pressed.
O Pressing the [OK] key cancels the distance stake out measurement and returns to the
previous measurement mode.
44
Special Functions
11-4. Offset Station Measurement
The [OFFSET STA.] program is used for easy determination of the widths to the right and left
of a center line, by setting the instrument on the center line.
Overall flow diagram
Select the special function, using the procedure described on page 41.
Use the key to enter the Offset Station mode, and the [OK] key to switch to the center
aim screen.
(Following the guide messages, sight the center stake, and select whether the distance
tothe center stake is to be input or measured.
CENTER
AIM
Base Distance
Enter Measure
- | Select "Enter"
(to input the distance, go
to step (4).
Select "Measure"
(to measure the distance,
go to step ‘&)).
45
Special Functions
To input the distance
If "Enter" is selected, the measurement points of the widths can be determined by inputting
the distance and the width to the center stake as specified by the design.
@input the distance to the center stake, select the direction in which the width stake is to be
set (left or right), and input the width. The design value (horizontal angle) and the distance
are displayed. (For instructions on specifying the values, see steps 4, 5, and 6 on pages 43
and 44, "Distance Stake Out Measurement".)
> _ —
SET | SIDE SELECT OK OFFSET DIST.
DISTANCE LEFT RIGHT | — [i
OK | Design value (horizontal
| angle) and distance are
| displayed
Rotate the instrument in the horizontal direction, set the angle to 0-00'00”, and secure the
horizontal rotation of the instrument.
— — —
Rotate instrument Secure | ОК | Distance to measurement
in horizontal Instrument at | [ point and horizontal distance
direction angle of "0 are displayed
Moving the prism, measure the distance, and set the point at which the distance becomes
"0" as the width.
a "eu | a Select width position
Move prism and Set distance "0 OK o direction and return to
p as measurement т -
measure —_ fan —- distance for next point.
fr |
point
(7Repeat the above procedure starting from (© until all of the necessary points on the left
and right, or the 2nd and 3rd points, have been determined.
O Pressing the [S. FUNC] key during measurement returns to the beginning of the offset
station measurement function. Pressing the [S. FUNC] key once more at this poínt exits the
special functions mode and returns to the normal measurement mode.
46
Special Functions a
To measure the distance
Selecting "Measure" enables the measurement points of the width to be determined by
measuring the distance to the center stake and then inputting the width.
(8)Measure the distance to the center stake, select the direction in which the width stake has
been set {left or right), and input the width. The design value (horizontal angle and thehorizontal
distance) are displayed.(For instructions on specifying the values, see steps 4, 5, and6 on
pages 43 and 44, "Distance Stake Out Measurement”.)
+
Specify distance | Select width ji K
to center stake © position direction
| Specily width
Design value (horizontal
angle and horizontal
distance) are displayed
i
i.
(Continue repeating steps ©) to until all of the necessary measurement points have
been determined.
@Pressing the [S. FUNC] key during measurement returns to the beginning of the offset point
measurement function. Pressing the [S. FUNC] key once more at this point exits the
special functions mode and returns to the normal measurement mode.
47
‘Special Functions
11-5. Lot Staking Measurement
With the lot staking function, the input datum station distance (the linear distance on the
design or the measured linear distance) can be divided into N equal segments and
measured.
Overall flow diagram
LA
\
xance
Gel
siope o
+ Difference in height
ЙА
Fat 1 + 2 + 3
N equal division design value
——— = P01
Horizontal distance = P02
= P03 N times design value
(DSelect the special function, using the procedure described on page 41.
DUse the key to enter the lot staking mode, and the [OK] key to select whether the datum
station distance is to be input or measured.
K 7 Select "Enter"
Datum Stasion O
Distance Enter | (to input the distance,
Measure uu go to step 3)-
Select "Measure" |
(to measure the distance, |
go to step ©).
48
Special Functions
To input the distance
When "Enter" is selected, the distance determined by the design is input, and divided into N
equal segments.
(First, use the key to select the type of distance (horizontal distance, slope distance, or
height differential), and then specify and input the distance to the datum station and the
number of segments.
(For instructions on specifying the values, see steps 4, 5, and 6 on pages 43 and 44,
Select |, Specify | Push the 1, Specify “ox
O
K > Specified distance to
distance distance to OK number of
ist measurement point
To is displayed
type datum station Key segments
(4 )Measure the 1st measurement point (the first segment point).
a. Position the person holding the prism on the line and measure the distance to the prism.
(The design distance and the difference between design and measured are displayed.)
b. Guide the person holding the prism to the point where the range reads 0 m. (The range
changes as the prism moves.)
c. The point where the distance reads 0 is the 1st measurement point.
(5When the 1st measurement point has been specified, press the [OK] key to change the
screen to show the distance to the 2nd measurement point. Specify a number of segments
for the 2nd point in the same way as for the 1st point, and press the [OK] key to exit the lot
staking function and return to the normal measurement mode.
To measure the distance
Select "Measure" to measure the distance to be divided, and to divide it into equal segments.
ln the same way as for step ©, use the key to select the type of distance. Then measure
the distance to the datum station, specify the number of segments, and specify the
measurement point.
| Select |, Measure — — Specity 7 - Repeat steps D-O to
di t | .
| distance Istanc number of na K specify measurement
Pe or a 7 Ponts
7When all of the segments have been measured, press the [OK] key to exit the lot staking
function.
@Pressing the [S. FUNC] key during measurement returns to the beginning of the lot staking
measurement function. Pressing the [S.FUNC] key once more at this point exits the special
functions mode and returns to the normal measurement mode.
49
Special Functions
11-6. Coordinates Measurement
With the coordinates measurement function, the coordinates of any target point can be
determined, using the instrument position as the origin point. If necessary, new instrument
point coordinate values (N, E, Z) can be input, and the coordinate values for the target point
can be determined from the coordinates of the origin point.
Overall flow diagram
-N
Instrument point
(Select the special function, using the procedure described on page 41.
(2Use the key to enter the coordinates measurement mode, and the [OK] key to select
whether the instrument point coordinates which have already been input will be used as
the origin point, or whether new instrument point coordinates will be input. If known
instrument point coordinates are to be used as the origin point, select "Exist", and if
new instrument point coordinates are to be entered, select "Enter".
Select "Exist" (if instrument
point coordinates are known,
go to step @))
S.P, COORD
EXIT ENTER
Select "Enter" (to input
coordinates, go to step (3))
50
Special Functions
To input instrument point
(3'Specify and input the N, E, and Z coordinates for the instrument point.
(For instructions on specifying the values, see steps 4, 5, and 6 on pages 43 and 44, "Distance Stake
Out Measurement")
o I — ESP. | ZS.P. > O
SE BB coordinate coordinate in
a
Г py
To input instrument point
@ Specify and input the N, E, and Z coordinates for the instrument point.
(For instructions on specifying the values, see steps 4, 5, and 6 on pages 43 and 44, "Distance Stake
Out Measurement.)
Rotate Instument in >
horizontal direction and Sight scsi © K sin |
i i | E
specity desired point :
backsight angle Ca
_— Press [OK] to, | Distance to | к
у ” Zcoordinate
displayed
an NandE — 4
measure foresight coordinates
distance point | | displayed er
displayed
Ч
OPressing the [OK] key returns to the screen showing Step 3 so that the next target point can be
measured.
O Pressing the [S. FUNC] key during measurement returns to the beginning of the coordinates
measurement function. Pressing the [S. FUNC] key once more at this point exits the special
functions mode and returns to the normal measurement mode.
51
Special Functions
11-7. Resection Measurement
With the resection measurement, two known points (PA and PB) can be measured to find the
instrument point coordinates.
Overall flow diagram
Design value _
Opposite edge distance mesured voue. |
a
im
Point A E B
\ N /
/ \ | | \
UN 7
N
AN
=>
New point (N,E,Z)
(DSelect the special function, using the procedure described on page 41.
2)Use the key to enter the resection mode, and press the [OK] key to display the screen
where the instrument height is specified. Specify and enter values for the instrument
height, the NA coordinates, the EA coordinates, the ZA coordinates, and the prism height.
(For instructions on specifying the values, see steps 4, 5, and 6 on pages 43 and 44,
"Distance Stake Out Measurement".
| Specify
; instrument height
L
coordinate
52
NPA OK
| coordinate — Im...
Е Р.А
coordinate
Im —
ZP.A |
ок |
Specify prism
height of PA
: Special Functions
Gn the same way, specify and enter values for the NB coordinates, the EB coordinates, the
ZB coordinates, and the prism height.
(For instructions on specifying the values, see steps 4, 5, and 6 on pages 43 and 44, "Distance Stake
Qut Measurement.)
Zar P.B Toc J! EPB > ZP.B
ps coordinate Tal | coordinate
Specify prism — prism
eon ve PB | ox |
—
(Now measure the distance to PA and PB, to display the instrument point coordinates N and E.
| Sight = oK > Distance to = A и + Distance to —* N and E coordinates for
PA | | ho PA is | PBis instrument point are
displayed displayed displayed
Each time the .« key is pressed, the screen "ol changes from [Zcoordinates] to [NE coordinates]
and back to [Z coordinates).
(Pressing [OK] displays the value for the horizontal distance and height. Pressing [OK] again displays
a confirmation message asking if the instrument point is to be stored.
OSelecting "YES" stores the instrument point coordinates and exits the resection function. Selecting
"NO" returns to the beginning of the resection function, at step ©, so that the measurement can be
repeated.
Select YES or NO | K Select — Instrument point point
for instrument es ra are stored
> storage and resection ends
› п ге!
1 see Screen returns to If necessary,
beginning of
repeat
resection ( (step ©)
S. FINO E. Besen function |
O Pressing the [S. FUNC] key during measurement returns to the beginning of the resection
measurement function. Pressing the [S. FUNC] key once more at this point exits the special functions
mode and returns to the normal measurement mode.
53
Special Functions
11-8. Traverse Measurement
With the traverse measurement function, the coordinates of a new point can be determined based on a
known "instrument point coordinates and backsight point coordinates” or “instrument point coordinates
and directional angle”.
Overall flow diagram
Z
+
>. *
x 7
de nn
/ Y 7
TN / ;
SR / IN
У ad -
o 7 т
6 Y 7
Y
4 7
| /
B.S.point 7 /
7 7
TY у <= -
! ’ /
15 /
> CT
A Lama
(IN point Tg <
ae. K1 K2 о
TX “EB OT CA 7
ñ
- 4 [Prism height
с T3
- В
7
(DSetect the special function, using the procedure described on page 41.
Use the key to enter the traverse mode, and press the [OK] key to display the screen where the
"New" or "Continue" measurement method is selected.
a. To begin a new traverse measurement, use the [OK] key to select "New", and go to step 3).
b. To continue a traverse measurement using a different instrument point, use the key to move the
flashing point to "Continue", and press the [OK] key to select the item. The operation then begins
from step (3)
54
Special Functions |
When "New" is selected
With a new measurement, the known instrument point coordinates, to be used, are input as
the instrument point.
@BSpecify and input the known N instrument point coordinates,E instrument point
coordinates, Z instrument coordinates, and instrument height.
(For instructions on specifying the values, see steps 4, 5, and 6 on pages 43 and 44,
"Distance Stake Out Measurement".)
NP COORD > OK [ E S.P COORD oo * er como |
№
a = instrument height |
|
Press [OK] to specify whether the directional angle or the coordinates are to be used as the backsight
point.
a. If "Directional Angle" is selected, rotate the instrument horizontally to display a known directional
angle, and press [OK] to hold the angle.
b. If "NEZ" is selected, specify the known N, E, and Z coordinates, and press [OK] to enter them.
3% The selection is made in the same way as "b" of step 2).
(5)Sight the backsight point and specify the prism height. Then measure the distance tc the front sight
point. The X and Y coordinates for the new point are mn
--» —
Sight г. x Enter pr [енот Г 1 | sight fresiont
backsight ee point
point py
—
Distance to foresight N and E coordinates for
point is displayed foresight point are displayed
XThe key can be used to change the display to the Z coordinates.
(@Pressing [OK] displays a confirmation message asking if the coordinates of the front sight point are to
be stored.
a. Selecting "YES" stores the foresight point coordinates and exits the traverse function.
b. Selecting "NO" returns to the screen where the prism height is specified, at step (3), so that the
measurement can be repeated.
O Pressing the [S. FUNC] key during measurement returns to the beginning of the traverse
measurement function. Pressing the [S. FUNC] key once more at this point exits the special functions
mode and returns to the normal measurement mode.
55
Special Functions
11-9. Coordinate Stake Out Measurement
With the coordinate stake out function, three-dimensional coordinate stake out can be done, based on
known "instrument point coordinates and backsight point coordinates” or "instrument point coordinates
and backsight point directional angle".
Overall flow diagram
Z
4
N
ИА
NB point “Us
` | Prism
\ height
Staking point
Instrument
height
Instrument point /
- E
A
DSelect the special function, using the procedure described on page 41.
2)Use the '¥ key to enter the Coordinate stake out made, and press the [OK] key to display the screen
where the instrument point coordinates are entered.
(3)Enter the known N instrument point coordinates, E instrument point coordinates, Z instrument
coordinates, and instrument height.
(For instructions on specifying the values, see steps 4, 5, and 6 on pages 43 and 44, "Distance Stake
Out Measurement.)
- —
NS P | OK E ES. P >| ox _ - Specity |
COORD COORD instrument
height
56
Special Functions
(Press [OK] to specify whether the directional angle or the coordinates are to be used as the
backsight point.
a. lf "Directional Angle" is selected, rotate the instrument horizontally to display a known directional
angle, and press [OK] to hold the angle.
b.If "NEZ" is selected, specify the known N, E, and Z coordinates of the backsight point, and press
[OK] to enter them.
(The selection is made in the same way as "b" of step (>).
(3)Sight the backsight point and specify the known N, E, and Z coordinates of the measurement
point, and the prism height.
Sight OK > | OK |
backsight | | — Fm
point | Ce jo
height
© Pressing the [OK] key displays the design values calculated from the data input at steps (1) to e
(the horizontal angle and the horizontal distance). Rotate the instrument horizontally until the
angle reads 0°00'00", and lock the horizontal rotation of the instrument at that point.
| oser voue d > Rotate Lock Design value
| nonzonta de can instrument instrument (distance) is
orizona cs ance) | horizontally at angle of 0 displayed
are displayed |
@Specify the measurement point.
a. Position the person with the prism near the measurement point within the sighting range of the
telescope, and sight the prism. Measuring begins automatically, and the difference between the
design value and the measured value is dispiayed.
b.Guide the person with the prism to a point where the distance reads 0. (The distance changesas
the prism moves.)
Cc. The point at which the distance reads "0" serves as the measurement point.
(When the measurement point has been stored, press the [OK] key to confirm the height, and
then press it again to exit the coordinate stake out function.
@ Pressing the [S. FUNC] key during measurement returns to the beginning of the coordinate
stake out function. Pressing the [S. FUNC] key once more at this point exits the special
functions mode and returns to the normal measurement mode.
57
Special Functions
11-10. Remote Distance Measurement
With the remote distance measurement function, the remote distances (horizontal distance,
slope distance, height differential, and percentage grade) between a base point P1 and a
target point Px, as well as a target point Px and another target point Px, are measured.
Overall flow diagram
Siope distance ————= Target
a {Diff
Slope % |! ifference
Base point } ope 70 Вы | in height
TN
Na
\ Pou
MA 20
7
|
+
“Horizontal distance
(LSelect the special function, using the procedure described on page 41.
Use the Wkey to enter the remote distance mode, and press the [OK] display the screen where
the type of measurement can be selected. To measure the remote distance from a base point to
a target point , select [P — Pl, and to measure the remote distances from a base point to a
target point and from one target point to another, select [BP-P-P].
Select remote distance measurement
from base point to target point
| between 2 points (for P — P
| measurement, go to step (3))
Select remote distance measurement
from base point to target point, and
from one target point to another (for
BP-P-P, go to step 5)
58
Special Functions
P - P measurement
When [P - P] is selected, the remote distances from the base point to a target point between two
points are measured.
(3)As instructed by the message, measure the distances to the base point (P1) and the target point (P2).
Sight | Slope distance to , | [| [Slope distance .., Height differential between
hase base point and Sight © |OK
vertical angle are | pp.
point
| toP2and | base point and P2 is
(m vertical angle displayed, along with
displayed are displayed horizontal distance
€ Pressing the fl key displays the slope distance and percent grade.
O Pressing [OK] and sighting a new target point (P3) displays the remote distances from the base
point (P1) to the new target point (P3). Each time the target is changed, the remote distances
from the base point (P1) to the new target point (Px) are displayed.
@® To change the base point, use the [S. FUNC] key to go back to step © of the remote distance
function, and repeat the procedure starting from step (3), "Sight the base point".
@® Pressing the [S. FUNC] key during measurement returns to step ( of the remote distance
measurement function. Pressing the [S. FUNC] key once more at this point exits the special
functions mode and returns to the normal measurement mode.
BP-P-P measurement
With [BP-P-P] measurement, the remote distances from the base point to a target point, and from
the target point to another target point, are measured.
(5)As instructed by the message, measure the distances to the base point (P1) and the target point (P2).
Slope distance to | Gl _,[Slope distance | ,| — Height differential —
base point and Sight | |OK to P2 and between base point and
vertical angle are Po hy vertical angle P2 is displayed, along
displayed are displayed with horizontal distance
(6)Each time the . key is pressed, the display changes in sequence from the height differential to
the slope distance to the percent gradient.
@ Pressing [OK] and sighting a new target point (P3) and displays the remote distances from the
base point (P1) to the new target point (P3), as well as the remote distances (P — P) from the
previous target point (P2) to the new target point (P3). Each time the target is changed, the
remote distances (P — P) from the base point to the new target point and from the previous
target point to the new target point are displayed.
OTo change the base point, return to the (2) R.D.M and use the [S.procedure starting from step &
"Sight the base point”.
O Pressing !he [S. FUNC] key during measurement returns to step 2 of the remote distance
measurement function. Pressing the [S. FUNC] key once more at this point exits the special
functions mode and returns to the normal measurement mode.
59
Special Functions
11-11. Remote Elevation Measurement
With the remote elevation measurement function, a prism can be positioned directly under a target such
as a power cable, where it is impossible to position the prism directly on the target, and the distance to
the target can be measured.
Overall flow diagram
Height
|
{| Y Prism
/ \ height
Horizontal distance
select the special function, using the procedure described on page 41.
@lUse the [v] key to enter the remote elevation mode, and press the [OK] key to display the screen
where the prism height is entered.
(3 Following the guide messages, input the prism height. Then sight the prism and measure the
distance.(For instructions on specifying the values, see steps 4, 5, and 6 on pages 43 and 44,
"Distance Stake Out Measurement")
~ Specify the |_, Se > |, IR |
OK Sight | ; Siope distance -> Prism
prism neigh | the * OK — height(REM)
prism
. | toprismis '
(DAs the telescope is rotated in the upward direction, the perpendicular distance (REM) changes. When
the target point to be measured is sighted accurately, the height (REM) trom the ground to the target
point is displayed.
O Check the height to the target point and then press the [ESC] key to exit the remote elevation
measurement function and return to the normal measurement mode.
@Pressing the [S. FUNC] key during measurement returns to step ) of the remote elevation
measurement function. Pressing the [S. FUNC] key once more at this point exits the special functions
mode and returns to the normal measurement mode.
60
12. Initial Settings
12-1. About Initial Settings
With the PCS-200 series, there are numerous usage conditions which can be selected and specified by
the user. These are called "initial settings".
The initial settings are grouped into five modes, from the A Mode to the E Mode. The user can select
and store the contents of each of these modes, as described below.
When the instrument is shipped from the factory, those settings (at the left end of the screen) are
stored.
If a setting needs to be changed, follow the instructions on page 65, "Accessing the Initial Settings”, and
page 67, "Changing the Contenis of Initial Settings".
12-2. Initial Settings Mode A
IM Selecting the prism constant
This selects whether the input prism constant is to be
— 30 mm (— 30) or 0 mm (0), or whether a setting
selected by the user will be entered from the keyboard.
(Display)
PRSM CONST.
—30 0 ENTER
IM Selecting the atmospheric correction
This selects whether the temperature and atmospheric
pressure measured with the thermometer and barometer PPM CORR
will be entered from the keyboard (Enter), or whether the ENTER! NIL
atmospheric correction wilt normally be fixed at 0 ppm
(NIL) and no atmospheric correction will be used.
Hl Selecting the pressure unit PRES. CORR
This selects whether the input pressure unit will be
hPa, mmHg or "Hg (inch Hg). mmHg “Hg
BB Selecting the atmospheric refraction and earth
curvature correction
This selects whether the correction coefficient for the REF. COEFF.
input atmospheric refraction and earth curvature will be 0.14) 0. 20 NIL
"0.14", "0.2", or "NIL".If "None" is selected, no
correction is carried out.
12-3. Initial Settings Mode B
Hl Selecting the minimum display unit for angles
. Ш Е ANG. DISPLAY
This selects whether the minimum unit in which angles
are displayed will be 10" (COARSE) or 05" (FINE). COARSE FINE
61
Initial Settings
IM Selecting the minimum display unit for distances
This selects whether the minimum unit in which distances
are displayed during rapid (TRK) measurement will be
0.01 m (10 mm) or 0.001 m (1 MM).
Hl Selecting the vertical angle 0 reference
This selects whether the 0 reference point for the vertical
angle will be the zenith 0° (Z), horizontal 0° (H) or
whether the compass scale (COMP) will be used.
NM Selecting the angle type display
This selects whether the angles display in degrees,
minutes and seconds (DEG), grads (GRD), mills
(MIL) or decimal degrees (DEC).
IM Selecting the distance type display
This selects whether the distances display in meters
(M) or feet (FT).
12-4. Initial Settings Mode C
Hl Selecting shot/continuous measurement
(for normal measurement)
This selects whether measurement will be carried out
for the specified number of shots (SHOT) or
continuously (SERIES) until stopped.
Hl Selecting whether quick-shot is used
This is effective only when "SHOT" is selected at the
previous step (for normal measurement), and
selects whether the first measurement will start
automatically when the prism is sighted (ON) or
when the [OK] key is pressed (OFF). If "SERIES" is
selected at the previous step, this parameter is invalid.
Hl Selecting the number of shots
If shot measurement is selected in the Initial Settings
Mode A, this selects the number of shots. A value from
1 time (1) to 9 times (9) may be selected.
Hl Selecting auto measurement with continuous
measurement
If "SERIES" is selected at the previous step, this selects
whether measurement will start automatically when the
prism is started (AUTO) or whether it will start when
the [OK] key is pressed (MANUAL). (If "SHOT" is
selected at the previous step, this parameter is invalid.)
62
TR. DISPLY
10mm: 1mm
V ANG. MODE
Z] H COMP
ANG. UNIT
Deg Grd Mil Dec
DIST. UNIT
m ft.
MEASURE
SHOT. SERIES
QUICK SHOT |
OFF |
SHOT COUNT
123456789
AUTO MEAS.
AUTO” MANUAL
Initial Settings
Hl Selecting shot or continuous measurement
(for rapid measurement)
This selects whether high-speed measurement
"TRACKING" is to be repeated continuously until
stopped (SERIES), or is to be repeated for only
the specified number of shots (SHOT).
Hl Selecting the priority measurement mode
This selects whether the instrument starts from the
distance mode (DIST) or the angle mode (ANG).
Hl Selecting the display angle
(for slope distance displays)
This selects whether the angle displayed when a
slope distance is displayed will be shown as a vertical
angle (VER), as a percent grade (%) or whether a
horizontal angle (HOR) will be displayed.
Bl Selecting the display angle
(for horizontal distance displays)
This selects whether the angle displayed when a
horizontal distance is displayed will be shown as a
horizontal angle (HOR), a vertical angle (VER) or
whether a percent grade (%) will be displayed.
IM Selecting the angle display
(for height differential displays)
This selects whether the angle displayed when a
height differential is displayed will be shown as a
percent grade (%), as a horizontal angle (HOR) or as
a vertical angle (VER).
Hl Selecting the order in which distances are displayed
This selects whether the display switches in the order
of horizontal distance (H) — slope distance (5) —
height differential (Y) each time the = key is
pressed, or whether the order will be horizontal
distance (H) — height differential (V) — slope
distance (S).
TRACKING
SERIES SHOT
INIT. MEAS.
DIST.| ANG.
SLOPE ANG.
—
VER % HOR
Lo ОННО НН
HOR ANG.
HOR| VER %
VER. ANG.
1%! HOR VER
SLOPE REDUC
‚HSV HVS
63
Initial Settings
12-5. Initial Settings Mode D
Hl Adjusting the LCD contrast
The LCD screen can be lightened by pressing the <key
and darkened by pressing the pkey.
Hl Adjusting the brightness of the illumination
The screen can be made brighter by pressing the 4 key
and darker by pressing the pkey.
ll Selecting whether or not a buzzer sounds when
measuring
This selects whether the buzzer sounds (ON) when the
beam returns from the prism, during rapid
measurements, and at other times, or whether no
buzzer sounds (OFF).
Hl Selecting whether or not the 90- buzzer sounds
This selects whether the 90" buzzer sounds (ОМ) or
does not sound (OFF).
Hl Selecting whether or not the horizontal angle is
retained when the power is turned off
This selects whether the horizontal angle is to be
retained (ON) when the power is turned off, or is not to
be retained (OFF).
Hl Selecting whether the Illumination Auto Power
Off function is used
This selects whether the illumination goes off
automatically (ON) or not (OFF) after 10 minutes.
Hl Selecting whether the power is turned off
automatically
This selects whether the power supply goes off
automatically (ON) ornot(OFF) after 10 minutes.
12-6. Initial Settings Mode E
This mode is used to handle communications
With peripheral devices.
IM Selecting the baud rate
This selects whether the baud rate is 12, 24, 48, or 96.
64
LCD DENSFTY
4LOW HIGH >
ILLUMINATION
4 DOWN UP >
EDM BUZZER
ON) OFF
QUAD. BUZZER
ON | OFF
H ANGLE SAVE
ILLUM. OFF
POWER OFF
| ON OFF
BAUD RATE
12] 24 48 96
Initial Settings
Hl Selecting the data bit
This selects whether the data length is 8 bits or 7.
Hl Selecting the parity
This selects whether no parity check is used (NON), an
odd parity check is used (ODD), or an even parity
check is used (EVN).
IM Selecting the stop bit
This selects the number of stop bits used, 1 or 2.
DATA BITS
@ 7
| PARITY
NON] ODD EVN
STOP BITS
12-7. Accessing Initial Settings A
1 Power supply key INIT.SET A
ONOFF,
NU {| |“
) 3
Holding down the <key while turning on
the power brings up the “Initial Settings A"
screen and enters Mode A. The "PRISM
PRSM CONST.
0 ENTER
| |”
CONSTANT" parameter is displayed.
2 OK key
of
МООА Of
E
Selection key
Use the Y or 4 key the necessary
number of times to bring up the desired
item.
65
Holding down the key while turning on the
power brings up the "Initial Settings B"
screen and enters Mode B.
INIT.SET B
Or
y
ANG. DISPLAY
COARSE FINE [g
||
po
Bring up any necessary items using the same procedure as with Mode A.
Holding down the key while turning on
the power brings up the "Initial Settings C"
screen and enters Mode C.
INIT.SET C
o |”
Flashing, 1
\ MEASURE
SHOT SERIES [8
or
||
Bring up any necessary items using the same procedure as with Mode A.
ati
12-10. Accessing Initial Settings D
1 Power key
Holding down the key while turning on the
power brings up the "Initial Settings D"
screen and enters Mode D.
INIT.SET D
| | *
1
LCD DENSITY
4LOW HIGH) E
|| |“
Bring up any necessary items using the same procedure as with Mode A.
66 % To access Mode E, hold down the [@] key while turning on the power.
Initial Settings
12-11. Example of Changing Initial Settings
(Selecting Atmospheric Correction)
As an example of how to change initial settings, we will look at the parameter for selecting the
atmospheric correction in Mode A.
Except for changing the LCD contrast and the illumination brightness in Mode D, all of the settings can
be changed using the same procedure. For instructions on changing the contrast and brightness
parameters in Mode D, please refer to "Adjusting the LCD contrast" on page 68.
INIT.SET A
Use the procedure described in page 65 | | | oF
to access Mode A, where the "PRISM }
CONSTANT" screen is displayed.
PRSM CONST.
0 ENTER
|| a
2 PPM CORR.
Use the Y key to bring up "PPM CORR". ENTER NIL
| Na
3 | \ Flashing
\
OK
ÉSESES PPM CORR.
ENTER NIL =
por
CN
ro
Using the p key, move the flashing | | |
display to the desired item, and then either
press the Y key to move to another item,
or press the [OK] key to exit the selection
function. Normally,when the power supply |
: is tumed on, the "TURN SCOPE" screen |
is displayed. |
To change this to "NIL", move the
flashing display to the"NIL" item.
@ 17 "NIL" is selected for the ppm correction function, or if values of 15°C and 1013 hPa (760
mmHg) are entered from the keyboard, "0 ppm" appears on the display.
Of "ENTER" is selected, enter the temperature and atmospheric pressure, following the
instructions on page 34, under "Correction Mode",
67
Initial Settings
12-12. Adjusting the LCD Contrast
The procedure is shown here for adjusting the contrast of the LCD. The same
procedure can also be used to adjust the brightness of the illumination.
INIT.SET D
jp ||"
When Mode D is accessed by following
the instructions on page 66, the "LCD 4
DENSITY" screen appears.
LCD DENSITY
4LOW HIGH» =
I
2 LCD DENSITY
Each time the pkey Is pressed, the | <dLOW HIGHD [=
contrast lightens. | / ок
3 LCD DENSITY
Pressing the 4 key darkens the contrast. 4 a a = |
O When the appropriate contrast level has been reached, move to another item, or press the
[OK] key to exit the adjustment function.
O Pressing the [OK] key returns to the initial status in effect right after the power supply is
turned on with the "TURN SCOPE" message displayed.
O To move to another selection item, use the Y key or 4 key.
08
13. Preparing for Measurement
13-1. Centering and Levelling the Instrument
Setting up the instrument and the tripod
(DAdjust the tripod so that the height is suitable for observation when the
nstrument is set on the tripod and there is sufficient room to extend and
contract the legs.
(2)Position the tripod so that it is approximately above the station on the ground,
gauging the position visually. Position the tripod shoes firmly on the ground.
(3 Attach the instrument to the Tripod head.
Instrument
/ Bottom Plate
Extend/contract ÿ Tripod head
/ 4 Center screw
ÿ \ Hook
Tripod shoe y
Centering and Leveling with the optical plummet
(D Look through the optical plummet
eyepiece, and rotate the eyepiece knob Center mark
until the center mark can be seen
clearly.
2)Rotate the focusing knob of the optical
plummet and adjust the focus to the
station mark on the ground.
(3)Look through the optical plummet and
tilt the instrument by adjusting the 3 pcs Optical
Leveling screws until the center mark
coincides with the mark on the ground.
(4Adjust the tripod legs to position the
bubble, of the circular vial, to the center.
(Be sure not to put your foot on the tripod
shoe, which may disturb the position of
the tripod.)
plummet
eyepiece
Focusing knob
69
Preparing for Measurement
Leveling with the plate
(UPlace the plate vial in parallel with a line joining
any two leveling screws. Adjust the two leveling 1% lave vials
screws, and position the bubble in the center of I
the vial. To adjust the screws at the same
time,turn them alternately in opposite directions. =)
(ZAdjust the remaining leveling screw so that the L | |
bubble in the other plate vial is positioned in the Hoveling screws
center. (A)
(3)Check to make sure the bubbles in the two plate —
vials are positioned in the center,and if AN Leveling
not,repeat steps © and © until they are ; Serene
centered. A | \
@Rotate the instrument 180° on the vertical axis, .u /)
and check to make sure the bubbles stay ——
N |
centered. (B) —— Plate vials
OSee the arrows in Figs. A and B to determine the relation between the
directionin which the leveling screws are turned and the direction in which the
bubble moves. The bubble moves in the opposite direction from that in which |
the left or right thumb moves.
If the bubbles do not remain centered at step (4, the plate vial needs to be
adjusted. See the instructions on page 73, under section 14-1.
70
Preparing for Measurement
13-2. Eyepiece Adjustment and Sighting
Eyepiece adjustment
Remove the telescope lens cap. a
Zn. . | . , Vetical Line
(2)Paint the telescope in a bright direction, and (Single)
rotate the eyepiece ring all the way in the
counterclockwise direction.
(3)Looking through the eyepiece, rotate the
, : . . — Vetical Line
eyepiece ring clockwise until the reticle / (Double)
: . Horizontal Line
appears at its maximum sharpness.
(reticle)
- Sighting Line
| OWhen looking through the eyepiece in step 3, make sure you can view the
target easily and comfortably, with no eye strain. Attempting to stare at the
reticle can cause parallax and eye fatigue.
Of the field is dark and the reticle is hard to see, press the © key to brighten the
field. For instructions on adjusting the brightness, please refer to page 64,
section 12-5, “Initial Settings Mode D’.
Target sighting
(DPoint the telescope at the target, using the collimator
sight, and tighten the tangent lock knobs.
Looking through the eyepiece, turn the focusing knob
Target
until the target is clearly visible. If the focusing is , Collimator
correct, the reticle will not move in relation to the object j
even when your eye moves slightly left and right. J
GUsing the tangent screws, align the reticle accurately | А |
with the target. Sighting a target
CO Turn the focusing knob to the right to focus on a nearby target, and to the left
to focus on a target which is farther away.
OAt step (2), parallax may interfere with the relation between the reticle and the
target, preventing accurate observation,
OWhen using the tangent screws to sight the target, always turn the tangent
screws in the clockwise direction (to the right). If the screw is turned past the
target point, bring it back past the optimum position and then turn it again in the
clockwise direction to find the proper position.
OThe target should be placed near the vertical center (the reticle) even when
vertical angle measurement is not required. If the target is large, position it
accurately between the two vertical lines to sight It.
71
13-3. Attaching and Removing the Tribrach
With the PCS-225, the tribrach can be detached from the instrument, allowing easy
replacement by a target or prism for functions such as traverse measurements.
Detachment
(DUsing the screwdriver provided as an accessory, loosen the screws that
secure the attachment lever in place.
2JTurn the attachment lever so that the arrow faces upwards.
Lift the instrument off of the tribrach.
Attachment
(UAlign the guide on the bottom of the instrument with the guide slot on the
tribrach, and set the instrument in place on the tribrach.
Turn the attachment lever so that that arrow faces downward. This completes
the attachment procedure.
Be careful never to turn the attachment lever unless necessary.
MTo avoid turning the attachment lever by mistake when it is not necessary to detach the
tribrach, or when transporting the instrument, be sure the screws securing the attachment
lever are tightened with the screwdriver.
BM The instrument can only be attached to the tribrach by aligning the guide with the guide slot.
Instrument
Guide mark
Tribrach
Recessed screw
Tribrach locking lever
72
14. Inspection and Adjustment
14-1. Plate Vials
Inspection
(Place the plate vial in parallel with a line joining any two leveling screws. Adjust
the two leveling screws, and position the bubble in the center of the vial.
(2)Adjust the remaining leveling screw so that the bubble in the other plate vial
is positioned in the center.
(3)XCheck to make sure the bubbles in the two plate vials are positioned in the
center, and if not, repeat steps 1) and 2) until they are centered.
(DLoosen the horizontal lock screw and rotate the instrument 180° on the
vertical axis.
(5)Check to make sure the bubbles stay centered. If so, no further adjustment is
needed.
Leveling screw
— A
| Plate vial
| , | ll / ) 4
\ NN N 7
> Plate vial
Adjustment
(DIf the bubble in the plate vial has moved from the center, adjust the leveling
screw parallel to the plate vial, and bring the bubble back to the center by half
the amount which it has moved.
(Using the adjustment pin, turn the bubble adjustment nut to bring the bubble
the rest of the way back to its correct position.
(3)Rotate the instrument again 180° on the vertical axis, and check to make
sure the bubble stays centered.
Plate vial
Plate vial
Bubble adjustment nut
73
Inspection and Adjustment
14-2. Circular Vial
Inspection
No inspection is necessary if the bubble of the circular vial is in the center after
inspection and adjustment of the plate vials.
Adjustment
If the bubble of the circular vial is not in the center, bring the bubble to the
center by turning the bubble adjusting screws with an adjustment pin.
Circular vial ~~. 5 | |
orl] —
7
Bubble adjustment screws
>
74
Inspection and Adjustment
14-3. Inclination of Reticle
Inspection
DSecure target Point A and sight it with the telescope.
Using the telescope fine adjustment screws, move Point A to the edge of the
field of view (Point A’).
@No adjustment is necessary if Point A moves along the vertical line of the
reticle.
Vertical line 2 Sight axis line
Adjustment
(If Point À is off from the vertical line of the reticle, first remove the eyepiece cover.
Using the adjusting pin, loosen the four reticle adjustment screws
slightly loosening each screw by the same amount, and then rotate the reticle
line around the sight axis and align the vertical line of the sight axis with Point A’.
(3 Tighten the reticle adjustment screws again by the same amount, and repeat
the inspection to make sure the adjustment is correct.
— Reticle adjustment
|
|
SCraws
9 |
| |
|
75
Inspection and Adjustment
14-4. Perpendicularity of Line of Sight to Horizontal
Axis
Inspection
(DPosition a target Point A at a distance 30-50 m away from the instrument, and
sight it with the telescope.
2)Loosen the telescope lock screw and reverse the telescope on the vertical
axis, until a point is sighted at a distance roughly equal to that of Point A. This
is Point B.
(3With the telescope still reversed, loosen the horizontal lock screw, rotate the
instrument around the vertical axis, and sight Point A again.
@Loosen the telescope lock screw and reverse the telescope on the vertical
axis, until a point is sighted at a distance equal to that of Point B. This is Point
C. (Return the telescope to the normal position.)
(No adjustment is necessary if Points B and C are aligned.
~——30~50m——
| © /
A a
30—50m
Adjustment
DIF Points B and C are not aligned, mark Point D at 1/4 the length of the line
BC, from Point C in the direction of Point B.
Using the adjustment pin, rotate the reticle adjustment screws horizontally
opposite each other (see preceding page), and move the reticle to sight Point О.
Repeat the inspection and make sure the adjustment is correct.
76
Inspection and Adjustment
14-5. Vertical 0 Point Error
This item should always be inspected when the adjustments described in sections
14-3 and 14-4 have been carried out.
Inspection
(DSet up the instrument and turn on the power supply.
@ Secure a target Point A at any desired location, sight it with the telescope,
and read the vertical angle y.
Reverse the telescope and rotate the instrument horizontally, sighting Point
A again at the reversal position. Read the vertical angie 2.
4 If y +£ =360", no adjustment is necessary.
+ there is significant deviation d (y + £ = 3607, please contact your local dealer
for adjustment.
77
| Inspection and Adjustment
14-6. Optical Plummet
Inspection
(LSet the instrument on the tripod, and position a sheet of white paper
underneath it with an “X” drawn on it.
@Looking through the eyepiece, move the paper until the center of the “X” is
roughly in the center of the field of view. Secure the paper in that position.
Using the leveling screws, align the center of mark of the optical plummet
telescope with the center of the “X” mark on the paper.
A)Rotate the instrument around the vertical axis, and check through the
eyepiece at each 90° position to see if the center mark is still aligned with the
center of the “X” mark.
If the center mark and the “X” are correctly aligned, no adjustment is necessary.
Optical plummet telescope adjustment screws
Adjustment
(CIF the “X” mark and the center mark are not aligned, first turn the cap on the
focusing knob of the optical plummet telescope in the counter-clockwise
direction and remove it.
CRotate the instrument and, at each 90° position, mark the point sighted with
the telescope on the sheet of paper, labelling the four points A, B, C, and D.
Draw lines connecting the opposite points (A and C, B and D), and mark the
intersecting point as 0.
(VUsing the adjustment pin, turn the four adjustment screws on the telescope to
align the center mark of the telescope with the O point on the paper.
Repeat the inspection starting from step (4) and check to see if the
adjustment is correct.
78
Inspection and Adjustment
14-7. Offset Constant
The offset constant rarely changes, but should be inspected once or twice a
year to make sure that it has not changed.
It can be inspected on a certified base line, or by using the simple procedure
described below.
Inspection
Select a flat location with a linear distance of approximately 100 meters, and
mark Points A, B, and C at approximately 50-meter intervals.
@Set the instrument at Point A and measure distances AB and AC.
@Set the instrument at Point B, and measure distance BC.
The offset constant (K) can be determined using the following equation:
K = AC - (AB + BC).
If the constant K is not close to O in the above inspection, the offset constant needs |
to be changed. Please contact your local dealer for this adjustment.
Instrument Prism Prism
LL naaa hee nana aaa aa na nano 0
Л \ /
fA / \ / \
a / \ /
A B C
Instrument Prism
Л
Л Л
LA aR
A B C
79
Inspection and Adjustment
14-8. Beam Axis and Sighting Axis
Always check to see if the beam axis and sighting axis are correctly aligned
after the adjustments described in sections 14-3 and 14-4 have been carried
Inspection
(Position the prism on the ground, at a point at least 50 meters from the instrument.
(2Accurately sight the center of the prism through the telescope.
(3Turn on the power supply and measure the distance to the prism.
If the light-receiving buzzer sounds immediately and the measurement value
is displayed within a few seconds, no adjustment is needed.
——— ее
!
Bf the instrument does not function as described in step (4), the surveying axis
and sighting axis need to be adjusted. Please contact your local dealer for this
adjustment.
Weather conditions should be as close to optimum as possible for this inspection.
Precautions regarding inspections and adjustments
Be sure to follow all steps in numerical sequence when carrying out
inspections and adjustments.
{With sections 14-3 and 14-4, in particular, make sure the inspection
and adjustment steps are done in proper sequence. Also, when the
adjustments described in sections 14-3 and 14-4 have been carried
out, always do the inspections noted in sections 14-5 and 14-8, and
check that the adjustments have been done correctly.
Always turn adjustment screws in the tightening direction and make
sure they are tightened securely when an adjustment has been
- completed.
After an adjustment has been completed, always repeat the inspection
and make sure the adjustment has been done correctly.
80
15. Appendix
15-1. Warning and Error Messages
45290
4
5
een arar.
3:
SENTI
5
3
E
К
e
хе
A:
5
3!
А a
Become dut
>
SERTE
пра ee
E euro Xp
ES i
Contents
The battery has run down.
The horizontal angle rotation
speed is too fast.
Replace or charge the battery.
Press the [0 SET] key and
start the measurement again.
The vertical angle rotation
speed is too fast.
Turn the telescope and specif
the index point again.
The input data exceeds the
allowable range.
The measurement range has
been exceeded.
A problem has occurred with the
distance measurement section.
“XX” indicates the error number.
Press the [OK] key and enter
the correct data.
Measurement is not possible
in this range.
Try the measurement again,
within the measurement range.
Turn the ON/OFF switch off and
A problem has occurred with the
angle measurement system.
“XX” indicates the error number.
Another problem has occurred
inside the instrument. “XX”
indicates the error number.
then on again. If the error is still
displayed, the instrument needs :
repair.
(Note)
This can sometimes be displayed
as a result of incorrect handling.
Appendix
15-2. Atmospheric Correction
The speed at which light travels through the air varies depending on the
temperature and atmospheric pressure. The PCS-200 series is designed to
measure distances at the speed of light. In order to measure accurately,
atmospheric correction needs to be used. The instrument is designed to correct
for weather conditions automatically if the temperature and pressure are input.
Correction is then carried out based on the following formula.
Calculation formula
79.55626 + P
573.14941 +1 X10
K=(279.75207—
82
K: Atmospheric correction constant
P: Atmospheric pressure (hPa)
t: Temperature ('C)
Distance after atmospheric correction D = Ds (1 + K)
Ds: Measured distance when no atmospheric correction is used
Appendix
15-3. hPa and mmHg Conversion Tables
Converting from hPa to mmHg
hPa | o 10 20 | 30 | 40 | 50 60 | 70 | 80 | 90
500 | 376” 383° 390” 398”, 406° 413 | 430 428 | 435 443°
600 | 450 458 | 465 | 473 | 480 488 | 495 503 510 518
700 | 525 533 | 540 548 | 555 | 563 | 570 578 | 585 | 593
800 | 600 | 608 | 615 | 623 | 630 | 638 645 | 653 660 | 668
900 | 675 | 683 | 690 | 698 705 | 713 | 720 | 728 735 | 743
1000 | 750 | 758 | 765 | 773 , 780 | 788 | 795 | 803 | 810 | 818
1100 | 825 833 840 848 | 855 | 863 | 870 878 885 | 893
1200 | 900 | 908 | 915 923 | 930 | 938 | 945 953 | 960 968 |
Converting from mmHg to hPa
mmHg| 0 | 10 20 | 30 | 40 50 | 60 | 70 | 80 90
400 | 533 547 560 573 587 600 613| 627 | 640 653
500 | 667 680| 693 707 720 733 | 747 760 | 773 | 787
600 | 800| 8131 827! 840' 853, 867) 880 893 907, 920
700 | 933 947| 960 973 987 | 1000 | 1013 | 1027 1040 | 1053
800 |1067 1080 | 1093 1107 | 1120 | 1183 | 1147 1160 | 1173 | 1187
| 900 [1200 1213 1227 1140|1153|1167 1180, 1193 1207 1220
83
Appendix
15-4. Deviation When No Atmospheric Correction Is
Made
When measurement is carried out with no atmospheric correction (with the
settings fixed at a temperature of 15°C and an atmospheric pressure of 1013
hPa or 760 mmHg), the deviation per 100 meters in temperature and pressure
will be as shown in the tables below.
With hPa (15°C, 1013 hPa as standard)
© !Pa| 1200 | 1100 | 1013 ‚ 900 | 800 | 700 | 600 | 500
45 | 20 | —0.5 —26 | —55 | —80 —10.5,—130 —155
35 | 30 | 04 | —18 | —47 | —73 —99 | —125 —154
| 25 | 40 | 14 | —09 | —a0 —66 | —93 —12.0 | —14.6
15 | 52 24 —0,0 | —3.1| —59 | —86 | —11.4| —14.2
5 | 63 35 10 | —22 | —5.1 —8.0 —108| —13,7
-5 | 76 | 47 | 21 | —13 —42 | —72 ,—102 —13.1
| —15 | 90 59 | 32 | —02 | —3.3 | —64 —95 | —126
Unit = millimeter
With mmHg (15°C, 760 mmHg as standard)
o™ 900 800 | 760 | 700 | 600 | 500 | 400
45 | 20 | —13 | —26 —46 | —80 | —113 —146
35 | 30 —04| —18 | —39 —73 —108 —142
25 | 40 | 05 | —09 —31 | —66 —102 —137
15 | 52 | 15 | 00 | —22 | —59 | —96 | —133
| 5| 63 | 25 | 10 | —13 | —51 | —89 | —12.7
-5 | 76 | 37 21 —03 | —42 | —82 | —12.2
—15 | 90 | 49 | 32 | 08 | —33 | —74 | —115
Unit = millimeter
* When the actual pressure is 1013 hPa (760 mmHg) and the temperature is 25 C,conducting
the measurement with the temperature left at 15°C will result in the measurement being
short by 0.9 mm per 100 meters.
84
Appendix
15-5. Atmospheric Refraction and Earth Curvature
Correction
@® Atmospheric refraction and earth curvature correction refers to correcting both
the bending of the light beam caused by atmospheric refraction and the effect
on the height differential and horizontal distance caused by the earth curvature.
@ Correction called “atmospheric refraction and earth curvature correction”is
initiated to correct deviation when the slope distance and vertical angle are
used to determine the horizontal distance and the height differential. With
this instrument, the following formula is used to correct these factors.
@Calculation formula when atmospheric refraction and earth curvature
correction parameter is set to “ON”:
Corrected horizontal distance (H)
LA K-2
2Re
H = S(Cos a + Sin à '
S-Cos a)
Corrected vertical distance (V)
1K
H = S(Sin a + Cos «a - >Re
S-Cos a)
@ Calculation formula when atmospheric
refraction and earth curvature
correction parameter is set to “OFF”;
Re =6,370km
Horizontal distance H' = S-Cos «
Vertical distance V' = S Sin a
S: Slope distance
a: Vertical angle from horizontal
K: Atmospheric refraction coefficient (0.14 or 0.2)
Re: Diameter of earth (6,370 km)
85
Appendix
15-6. Distance Range
Generally speaking, the maximum range which can be measured varies
considerably depending on the atmospheric conditions. For this reason, the
performance tables on the following pages illustrate the values for both optimum
and ordinary weather conditions.
It is extremely difficult to judge when weather conditions are “optimum” and
when they are “ordinary”. With this instrument, the conditions noted below are
used to differentiate between the two situations. (Optimum weather conditions
for surveying are different from ordinary weather conditions, and in surveying
situations, cloudy skies are considered more favorable than sunny skies.)
86
Weather conditions for measurement ranges are based on the following standard values:
Normal:Visibility of approximately 20 km, with slight haze
Good: Visibility of approximately 40 km, overcast, no heat haze and moderate wind
16. Specfications _
Instrument
Telescope
Magnification. 0x
Effective aperture + 45 mm (EDM 45 mm)
Resolving power - J TN
Field of view -- -- + 2.6% (17303
Minimum focus 085 m/2.,8 ft.
Distance Measurement Section
Measuring range Normal Good
1 prism on 800 m/ 2625 ft. (1000 m / 3280 ft.)
3 prism 1200 m /39351t. (1500 m / 4920 ft.)
Ассигасу e Z (3 + 3 ppm x D) mm
Measurement display----8 digits,max. display 99999.999m
Minimum readings
Fine mode ---- - e e mm / L001 В.
TR mode 1 om, 1 mm/.1 ft, .0O1 ft.
Measuring time
Fine mode =. Approx. 2 seconds
TR mode -- Approx, 0.8 seconds (mm)
Measuring system
Normal Measurement repeated automatically
Shot iio
Max. slope distance display -- ~~ 3,000 m
..-. ...- Selectable from 1 to 9 times
Atmospheric correction. Temperature: 1° C / 1° F per step input
(On/Off selection) - - Pressure: 1 mmHg / 0.1 inHg per step input
Prism constant ---0 mm, -30 mm, selectable numeric input
Atmospheric refraction and earth curvature - -- --ON / QFF
Atmospheric refraction coefficient 0.14 /0.2
Distance unit Meter / Feet
Calculation functions +... 46400600060 Distance Stake out
Lot staking
Offset point
Remote elevation measurement
Remote distance measurement
Coordinates
Resection
Traverse
Coordinate stake
Angle Measurement Section
Measuring system ее: Incremental rotary encoder
Detection method ---- -----.--- Horizontal angle- Double
Vertical angle- Single
Minimum display 10" / 5" Selectable
Accuracy (DIN18723)- - Horizontal : Standard deviation 5"
Vertical : Standard deviation 7"
Measuring time ~~ Approx. 0.2 seconds (continuous measuring)
Diameter of encoder 5009 79 MM
Measuring modes ~~ Horizontal angle Right, Left, Hold
Vertical angle Zenith 0%, Horizontal 0%, % , Compass
Display Section
e LCD 2 lines with illumination
PCS-225: Dual
PCS-215: Single
Display combinations Vertical angle/Horizontal angle
% / Horizonta! angle
Horizontal distance / Horizonta! angle
Slope distance / Vertical angle
Height differential / % X
X coordinates / Y coordinates / Z coordinates
Vertical distance / Vertical angle[REM]
Height differential / Horizontal distance [ROM]
Slope distance and %
Sensitivity of Vials
40" 2 mm
ce 8" / 2 mm
Plate vial —
87
Specfications
Optical Plummet
3
D
O
D
(T1
—
La
o
==
=
a
Types of Vertical axis and Tribrach
Vertical axiS Single axis
Tribrach type. PCS-225: Detachable
PCS-215: Fixed
Data Communication
Interface --:::50-0000 5 AS-2326 standard
Baud rate e 1200, 2400, 4800, 9600
Data bits e 5 8 07 7 bits
Parity bit «None, Odd, or Even
Stop bits eee 1/2
Auto Power Off Function
Time setting 10" {On/Off selectable)
Ambient Temperature
Temperature range. 20 ~ 450°C
Tripod Thread
PCS-215/225 5/8" 11 (JIS Type B)
Dimensions and Weights
Instrument (w/o battery) ---- -162(YWx 338(H)x 154(Limm 4.7kg
Case... 2000W)x 250(H)x 440(L)mm 3 kg
On-Board Battery (MBO6
Роууиег вирр! = Rechargeable Ni-Cd battery
Output voltage e 7.2 МОС
Opeation time per charging---Continuous : approx. 4 hours
(Angle/Distance measurement)
Continuous: approx. 15 hours
(Angle measurement only)
Weight == 0,3 Kg
©
8
Battery Chargers
Quick Charger for Internal Use
(MC04)
Input voltage AC 120V
(fer USA)
AC 240V
(for Europe)
Input frequency -----.- e BOBO HZ
Charging time 0 Арргох. 1.0 hour
Ambient usage temperature -—0-+45C
Weight 0.35 kg
17. External Battery (MB07)
In addition to the on-board battery (MB06), the PCS-215/225 can be connected
to a long-term continuous external battery (MB07). If both the on-board battery
(MB06) and external battery (МВО7) are connected to the instrument at the
same time, the power is supplied only from the external battery (MBO7) without
consuming the on-board battery (MB06). The MBO7 can be charged by means
of a MC04 charger.
17-1. MBO7 Specifications
Type === nene ene een Rechargeable Ni-Cd battery
Output voltage +44 er ee EEE cennens 72V
Continuous usage hours per full charge +5 14.5 hours
(Distance & Angle measurement)
54 hours
(Angle measurement only)
“Cable MB45 00er ceraere seras Length 2m
17-2. MC04 Specifications
Input voltage eee eee amer in nremenrar can eEmerm rnIceirererrerenran rc nmimiorar A. AC 120V / 240V
Frequency «rer EEE EEE 50/60 Hz
Charging time ++ pene ease aaa e senna Approx.4 hours
Ambient usage temperature «oe OC- 45C(+32F- +113F)
17-3. How to attach the MB07
Attach the MB07 to the tripod, and connect ther MBO7 to the instrument connector by means of
a MB45 battery cable.
17-4. How to charge the MB07 by means of MC04
(I> Connect the MC04 connector to the MBO7 connector terminal.
(2) Insert the MCO04 plug in a wall outlet (AC 120V/220V,50/60 Hz).
(3) Disconnect the MCO4 connector from the MB07 connector terminal, and unplug the MC04
plug to terminate charging after approx. 4 hours.
Note:
1. The "Auto power off" function can work as well when the MBO7 is used.
2. Please refer to the MBO7 instruction manual when the MB07 is charged.
89
External Power Supply
17-4. Charging the Battery
(DConnect the external battery and the charger (MC22).
Plug the charger into a household outlet (AC 120V / 220V,50/60 Hz).
Turn on the power supply switch on the external battery and check to make
sure the pilot lamp on the charger lights.
[After 14-16 hours, turn off the power supply switch, unplug the charger, and
disconnect the charger and the battery.
Do not charge batteries for longer than 24 hours, as this can damage the battery.
Ef the pilot lamp on the charger does not light when the power supply switch on
the external battery is turned on, either the battery or the charger may have a
problem.
TE) Connector
External battery Charger MC22
External Battery MB22
Note:
The external battery charger MC22 cannot be sold in EU countries.
90
r FL e A A A
1 This device complies with the protection requirement for
residential and commercial areas. If this device is used
| close to industrial areas or transmitters, the equipment
can be influenced by electromagnetic fields.
PENTAX
ASAHI PRECISION CO., LTD.
1-1- 21, Shirako, Wako-shi,
Saitama-ken, 351-0101, Japan
Tel: +81-48-461-5377
Fax:+81-48-466-3979
CE
The CE marking assures that
this product complies with
the requirements of the EC
directive for safety.
06.1995 First edition
03.06 2000 Third edition
TS00304E
Printed in Japan
">
/
Изтегляне
Само приятелско напомняне. Можете да видите документа точно тук. Но най-важното е, че нашият AI вече го е прочел. Той може да обясни сложни неща на прост език, да отговори на вашите въпроси на всеки език и да ви помогне бързо да навигирате дори в най-дългите или най-сложните документи.
Реклама