Schlage CT500 Universal Access Controller Access Control System Installation & Programming Manual

Below you will find brief information for Access Control System CT500 Universal Access Controller. The CT500 Universal access controller can be interfaced to any Schlage access control devices such as iButton readers or Keypads. The CT500 can also be used with mag-stripe emulation output HID Prox Card readers as well as magnetic stripe card readers. The unit may have been ordered with the PS option (505 power supply in the same enclosure). If it does not have a supply, one will be required. Make sure that the supply chosen will meet the electrical requirements of all components in the system. Note that electrical power gets dissipated over long wire runs so it is important that the equipment be located close to the opening it is controlling.

PDF
Document
Schlage Access Control System CT500 Universal Access Controller Manual | Manualzz

Advertisement

Advertisement

/

Advertisement

Key features

  • Connects to iButton readers, Keypads, mag-stripe and Prox Card Readers

  • Supports up to 500 Codes, Cards or iButtons

  • Can be programmed manually or via computer

  • Supports day/night and 24-hour access modes

  • Includes several configurable timer options

  • Offers a variety of programming and security features

  • Supports door forced/propped alarms

  • Provides Master iButton/Card initialization

  • Allows for keypad/100CAB initialization

  • Supports System 7 programming

Frequently asked questions

The CT500 can hold up to 500 user codes, cards, or iButtons.

The CT500 is compatible with iButton readers, Keypads, mag-stripe readers, and Prox Card readers.

You can program the CT500 manually via a keypad or using computer software. The manual provides detailed instructions for both methods.

The CT500 supports day, night, and 24-hour access modes. You can program cards/iButtons/codes to function during specific times using an external timer.

The CT500 has four adjustable timers: A, B, C, and the Door Propped Delay. You can assign different timers to different user codes, cards, or iButtons.

Follow the instructions in the manual for initializing a Master iButton/Card. This step is crucial for initiating programming and ensuring system security.

You need to install a door position switch and configure the system accordingly. Refer to the manual's instructions for details on wiring and configuration.

Yes, the manual provides steps for erasing the memory and restoring the unit to its factory default settings.

The manual provides a table with error codes and their corresponding meanings. Use this table to diagnose and resolve any programming issues.