SmartSat™
Pulse Oximetry Analyzer
Operation Manual
mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
Notices
Shipping Address:
mtk Peter Kron GmbH
Zossener Strasse 41 - 10961 Berlin - GERMANY
Sales & Service,
Technical Support: 0049 - 30 - 69 81 88 40
Facsimile:
0049 - 30 - 69 81 88 49
Email: [email protected]
Web Site:
www.
mtk-biomed.de
In the interest of continued product improvement, all specifications are subject to change without notice.
mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
Revision History
1 May 1995
10 December 1998
14 January 1999
19 August 2002
3 December 2002
10 October 2003
15 December 2003
05 January 2004
Release at revision 00.
Release at revision 01
Release at revision 02
Release at revision 03
Release at revision 04
Release at revision 05
Release at revision 06
Release at revision 07 mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
iii
Revision History iv
mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
Warranty Service & Shipping Instructions
Warranty Service
All repairs on products under warranty must be performed or approved in writing by mtk Peter Kron GmbH
Service personnel. Unauthorized repairs will void the warranty.
Assistance
If the product fails to function properly, or if assistance, service or spare parts are required, contact mtk or send an email. After this form has been submitted, an mtk Representative will help you to solve your problem.
Before contacting, please attempt to duplicate the problem and to check all accessories to ensure that theyare not the cause of the problem. Prior to calling please be prepared to provide:
1. Product Name, Model Number, Serial Number and Software version.
2. Complete description of the problem including the conditions under which the problem occurred. Ideally, a written problem description would be provided, allowing for more efficient handling of your initial service request and the subsequent diagnosis and remedy of the problem.
3. Your institution's complete name and address. Please also provide a contact name and phone number.
4. A purchase order number if the product needs non-warranty service or you are ordering spare parts.
mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
v
Returning a Product for Service
Warranty &Factory Service Instructions
If it is determined that you need to ship the unit back, it is highly recommended that you pack the product in its original shipping carton and packing materials, provided that they are still useable. If the original packaging is not available, select a sturdy corrugated carton large enough to hold whatever items you are returning, and also to allow 4 to 6 inches of packing material on all sides of the items. Whether you use the original packaging or an appropriate substitute, please follow these packing instructions:
1. Remove all hoses, cables, power cords and any other accessories from the instrument and, if possible.
Note: if you are using substitute packaging, it is essential that you seal the instrument in a clean, static free plastic bag or in clean bubble wrap in order to prevent packing material from entering the product.
2. Pack only the accessories you are requested to return; place them in a separate bag.
3. If you are using substitute packaging, create a foundation of 4 to 6 inches of packing material (either bubble wrap or packing "peanuts") at the bottom of the carton.
4. Insert the instrument and the accessory bag into the shipping carton.
5. If you are using substitute packaging, fill the 4 sides and the top of the carton with 4 to 6 inches of packing material (either bubble wrap or packing "peanuts"). Ensure that the instrument and accessory bag are held firmly in place by the packing material.
6. Please place paperwork such as the purchase order, contact info and reasons for return in the top of the carton.
7. Close the carton and securely seal it with tape; since in most cases the carton will have been previously used, it may be necessary to reinforce the original tape on the bottom of the carton.
8. Ship the product via whatever carrier (UPS, FedEx, etc.) is most convenient. However, please be aware that, depending on where you are shipping from, standard UPS ground shipping could take as long as 7 business days. Unless other arrangements are made, mtk will return the repaired product to you via UPS.
Additional Instructions for International Shipments
9. Shipping insurance is optional. Claims for damage to the product during shipping must be initiated by the shipper.
Customers outside the United States must include a "pro-forma invoice" for customs purposes as part of their shipping documents. It is imperative that the name of the product appears exactly as follows:
SmartArm Test Equipment
Or
SmartSat Test Equipment
The use of any other product name could add unnecessary delays when shipping internationally. mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
Table of Contents
Notices..................................................................................................................................... ii
Revision History..................................................................................................................... iii
Warranty Service & Shipping Instructions......................................................................... v
Contents................................................................................................................................. vii
Warranty................................................................................................................................. vii
Precautions............................................................................................................................. ix
Section 1: Introduction......................................................................................................... 1-1
Section 2: Product Description............................................................................................ 2-1
Section 3: Physical Description............................................................................................ 3-1
Section 4: Installation and Operation................................................................................. 4-1
Section 5: Frequently Asked Questions.............................................................................. 5-1
Section 6: Oximeter Compatibility Chart.......................................................................... 6-1
Section 7: Remote Control................................................................................................... 7-1
mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
vii
Warranty
mtk Peter Kron GmbH (mtk) warrants to the purchaser that the SmartSat Pulse Oximetry Analyzer shall be free from defects in material and workmanship for 3 years for U.S. customers and 1 year for international Customers. mtk's sole obligation with respect to any such defect is limited to the repair with new or remanufactured parts, or at mtk's option, replacement of the SmartSat, or refund of the purchase price.
This warranty is made on the condition that prompt notification of a defect is given to mtk within the warranty period. mtk shall have the sole right to determine whether a defect exists.
This warranty extends to the original purchaser only. This warranty does not apply to a SmartSat that has its tamper seals removed or cut, altered, subjected to misuse, negligence, unauthorized repair, or accident, or operated other than in accordance with the instructions.
This warranty represents the exclusive obligation of mtk and the exclusive remedy of the purchaser regarding defects in a SmartSat. This warranty is given in lieu of any expressed or implied warranties,
including the warranty of merchantability or fitness for a particular purpose, which warranties are disclaimed. No person is authorized to modify, in any manner, mtk's obligation described above.
mtk shall not, in any case, be liable for special, incidental, or consequential damages arising from breach of warranty, breach of contract, negligence or any other legal theory.
viii
mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
Precautions
To maintain battery life, it is recommended that the battery be cycled (discharged and fully recharged) after every 30 hours of use. This will provide optimum battery performance throughout the life of the battery.
For optimum SmartSat performance, it is recommended that the SmartSat be allowed to "warm up" for 5 minutes before use.
For accurate results, it is recommended that you use the oximeter interface cables provided with the
SmartSat. If you should damage or misplace these cables, please contact the factory for replacement. Use
of cables other than those provided by mtk may result in inaccurate test results.
mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
ix
x
mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
Section 1. Introduction
General
The SmartSat Pulse Oximetry Analyzer is the first test system available to test both the probe and pulse oximeter independently. This method allows the user to diagnose problems to either the probe or pulse oximeter. The SmartSat has two probe test modes and a SpO2 simulator mode with user programmable
Auto Sequences for automated testing.
The first probe test is the Probe Continuity Test. This tests the probe for opens, shorts, and intermittent probe problems. The Probe Continuity Test provides an electrical integrity test of the probe.
The second probe test is the Probe Sensitivity Test. This tests the sensitivity of the RED and IR LEDS and the ratio of the Red to IR sensitivity. This test is valuable for testing a probe during its functional life. The user can then determine if the probe is within an acceptable sensitivity range.
The SpO2 Simulator tests the pulse oximeter through a complete range. The full featured SpO2 simulator provides the following features: Oxygen Saturation; Pulse Rate; R-Curves for testing pulse oximeters and user programmable Auto Sequences for automated testing.
In addition to these testing features, the SmartSat incorporates a high-resolution graphic display, an internal battery, built in probe test ports and a compact, lightweight enclosure.
Intended Audience
The Operation Manual is intended for end users of the SmartSat Pulse Oximetry Analyzer. It contains installation and operation instructions, applications notes, performance limitations and routine performance verification procedures. To achieve satisfactory results, it is imperative that the operator read this manual thoroughly before attempting to use the SmartSat.
mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
1-1
Section 1. Introduction
Documentation Comments
mtk Peter Kron GmbH has attempted to present all information as clearly and error-free as possible. However, if you detect any errors or omissions, or wish to suggest improvements to the manual, please mail, fax or email your comments to:
mtk Peter Kron GmbH
Zossener Strasse 41
10961 Berlin
GERMANY
Fax: 0049(30) 69 81 88 49
Email: [email protected]
1-2 mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
Section 2. Product Description
Overview
SmartSat Pulse Oximetry Analyzer is a state-of-the-art instrument designed to provide accurate and
reliable performance. The following list presents some of the more salient features of the SmartSat.
• Standardized scientific procedure for electronically testing pulse oximeters.
• The first available Probe Analyzer for probe testing. The Probe Analyzer has two tests: The Probe
Continuity Test and The Probe Sensitivity Test.
• Full featured SpO2 Simulator: Oxygen Saturation and Pulse Rate; Ambient Light; Pulse Modulation
Simulation and user programmable Auto Sequences to automate common test procedures.
• Internal Battery allows testing in remote sites such as ICU, OR and other patient floors.
• 320 x 240 high resolution graphic display allows visualization of waveforms.
mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
2-1
Section 2. Product Description
2-2 mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
Section 3. Physical Description
The SmartSat Pulse Oximetry Analyzer is a microprocessor controlled patient simulator and probe analyzer housed in a compact (8 x 8 x 5 inch) and portable (6 pounds with battery) aluminum case. Performance and technical specifications are listed below.
SpO2 Simulator
Oxygen Saturation (SpO2)
• Range: 0-100%
• Resolution: 1%
• Accuracy: ±0.5% from 70-100%
±1% from 50-69%
R-Curves
• Preset manufacturer's R-curves: BCI, Criticare, Criticare SPOT, Datascope, Datex, Hewlett-Packard,
Masimo, Nellcor, Nihon Kohden, Nonin, Novametrix, Ohmeda and Sensormedics(contact the factory for availability of others)
Pulse Rate
• Range: 20-300 bpm
• Resolution: 1 bpm
• Accuracy: ± 1 from 20-199 bpm
± 2 from 200-300 bpm
Pulse Modulation
• Range: 0.10-20% of nominal amplitude
• Resolution: 1%
• Accuracy: ±1%
Probe Analyzer
Probe Continuity Test
Simultaneous Channels:
• 2 for Nellcor style probes: LED & photodiode circuits
• 3 for Ohmeda style probes: Red LED, IR LED, and photodiode circuits
Probe Connection
• Integral connectors for Nellcor & Ohmeda probes
• Adapters available for other manufacturer's probes mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
3-1
Section 3. Physical Description
General
Display
• Type: backlit graphics LCD (Liquid Crystal Display)
• Resolution: 320h X 240w, 0.36mm dot pitch
• Control: contrast adjustment
Serial Interface
• Type: RS232C, 9 pin D-connector, DCE
• Baud Rate: 1200 bps for Remote Control
• Mode: Remote Control
Printer Interface
• Type: Centronics type connector, 25 pin
Battery
• Type: Nickel Metal Hydride (NimH)
• Voltage: 19.2V
• Capacity: 2.1 Amp-Hour (Approximately 5 to 6 Hours operating Time)
• Charge time: 18 Hours
External Power Supply
• Type: Desk-mount linear
• Input: 120 VAC, 60Hz or 230 VAC, 50Hz or 100 VAC, 60 Hz
• output: 24VDC, 500mA, 6 foot cable
• Safety Agency Approvals: UL, CSA, CE, TUV
Physical
• Case: Aluminum, non skid feet, carry handle
• Dimensions: 8" wide, 8" deep, 5" high
• Weight: 6 pounds (including battery)
3-2 mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
Section 4. Installation & Operation
Unpacking
The SmartSat, manual, and accessories are shipped in one carton. Please note cables may be different, depending on what cables were ordered with SmartSat. Inspect the carton carefully for any signs of damage.
Remove the SmartSat from the carton and inspect the SmartSat. Retain all shipping materials for inspection by the carrier in case of shipping damage or for reshipment. The original carton and packing materials are to be used when the unit is shipped back to mtk for annual calibration.
Contents Checklist
1
1
1
1
1
1
QTY.
1
Checklist
SmartSat Pulse oximetry Analyzer
Service Manual
Nellcor SpO2 Simulation Cable
Ohmeda SpO2 Simulation Cable
External AC Adapter
Detachable Power Cord (US)
Foam Insert Set
Missing Items
If an item is missing or damaged, call Customer Service,
0049(30) 69 81 88 40
Indications and Contradictions
The SmartSat Pulse Oximetry Analyzer is intended for testing pulse oximeters and pulse oximeter probes.
The device is not designed, sold, or intended for use except as indicated.
The SmartSat Pulse Oximetry Analyzer is not to be used on patients either directly or indirectly.
mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
4-1
Section 3. Physical Description
General
Display
• Type: backlit graphics LCD (Liquid Crystal Display)
• Resolution: 320h X 240w, 0.36mm dot pitch
• Control: contrast adjustment
Serial Interface
• Type: RS232C, 9 pin D-connector, DCE
• Baud Rate: 1200 bps for Remote Control
• Mode: Remote Control
Printer Interface
• Type: Centronics type connector, 25 pin
Battery
• Type: Nickel Metal Hydride (NimH)
• Voltage: 19.2V
• Capacity: 2.1 Amp-Hour (Approximately 5 to 6 Hours operating Time)
• Charge time: 18 Hours
External Power Supply
• Type: Desk-mount linear
• Input: 120 VAC, 60Hz or 230 VAC, 50Hz or 100 VAC, 60 Hz
• output: 24VDC, 500mA, 6 foot cable
• Safety Agency Approvals: UL, CSA, CE, TUV
Physical
• Case: Aluminum, non skid feet, carry handle
• Dimensions: 8" wide, 8" deep, 5" high
• Weight: 6 pounds (including battery)
3-2 mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
Section 4. Installation & Operation
The SmartSat Main Menu
The SmartSat Main Menu will be displayed following power-up of the system.
Oximeter
Nellcor
OXYGEN SAT
(SPO2 %)
100
–DataLog–
PULSE RATE
(BPM)
75
PulseMod
5.00%
Probe Continuity
Open
L
E
D
Good
Short
O
T
O
P
H
Open
Good
Short
SglSwp
SpO2s im
F1
Probe-C
F2
Probe-S
F3
Setup
F4
BatChck
F5 MORE PREV
The main display is subdivided into three major windows:
1. Upper window (SpO2 Simulator)
2. Middle window (Graphic Display Measurements)
3. Bottom window(Control Panel Soft-keys)
The SpO2 Simulator features include:
• Oximeter Selection
• Oxygen Saturation (SpO2) ; range 0 to 100%
• Pulse Rate ; range 20-300 bpm
• Pulse Modulation; range 0.10-20%
• Programmable Auto Sequences
The SpO2 Simulator window has 4 main features. The Oximeter field displays the pulse oximeter being tested. The OXYGEN SAT field displays the oxygen saturation simulated. The PULSE RATE field selects the pulse rate simulated. The PulseMod field selects the perfusion of the pulse.
The Graphic Display Measurement (middle) window displays:
• Nellcor and other Two Trace type LED and Photo-diode continuity tracing
• Ohmeda and other Three Trace type RED, IR and Photo-diode continuity tracing
• Programmable Auto Sequences
• Advanced Simulation Features: Arrhythmia, Motion Artifact and Ambient Light, Set Up mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
4-3
Section 4. Installation & Operation
Control Panel Options:
Soft-keys can be utilized to navigate through screens to control all SmartSat features. From the main menu, the following options are available:
• F1 (SpO2Sim) accesses the SpO2 Simulator Menu.
• F2 (Probe-C) activates the probe continuity test
• F3 (Probe-S) activates the probe sensitivity feature.
• F4 (Setup) changes basic setup features.
• F5 (BatChk) Displays Battery Voltage
• MORE - advances the system to the next lower level in the menu tree. If there is no lower level the key will be inactive.
• PREV - returns SmartSat to the previous menu and saves any changes made to SmartSat
4-4 mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
Section 4. Installation & Operation
The SpO2 Simulator Menu
Purpose of SpO2 Simulator Menu: Used on a routine basis for preventive maintenance, quality assurance, trouble shooting and repair of pulse oximeters.
From the main menu, Press F1 (SpO2Sim) to enter the SpO2 Simulator menu. The PREV key will return the system to the main menu.
Oximeter
Nellcor
OXYGEN SAT
(SPO2 %)
100
–DataLog–
PULSE RATE
(BPM)
75
PulseMod
5.00%
Open
L
E
D
Good
Short
P
T
O
H
O
Open
Good
Short
SglSwp
Manual
F1
AutoSeq
F2 F3 F4
F5 MORE
PREV
From the SpO2 Simulator Menu the following options are available:
• F1 (Manual) enters the SpO2 Simulator manual test mode
• F2 (AutoSeq) enters the programmable Auto Sequences Directory
• F3, F4 and F5 are not used on this screen.
• PREV - will step back in the menu tree to the main menu.
• MORE is not used on this screen.
mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
4-5
Section 4. Installation & Operation
The SpO2 Simulator Menu, Manual Mode
Purpose of SpO2 Simulator Menu, Manual Mode: Used on a routine basis for preventive maintenance, quality assurance, trouble shooting and repair of pulse oximeters.
From the SpO2 Simulator Menu, Press F1 (Manual) to enter the SpO2 Simulator menu, manual mode. The
PREV key will return the system to the main menu.
Oximeter
Nellcor
OXYGEN SAT
(SPO2 %)
100
–DataLog–
PULSE RATE
(BPM)
75
PulseMod
5.00%
Probe Continuity
Open
L
E
D
Good
Short
P
T
O
H
O
Open
Good
Short
SglSwp
Advancd
F1
Select
F2
Select
F3
Change+
F4
Change-
F5 MORE
PREV
From the SpO2 Simulator Menu, Manual Mode, the following options are available:
• F1 (Advancd) introduces simulation features such as Arrhythmias, Motion Artifact and Ambient Light
Simulation. Note: When this is pressed, the Probe Continuity Test Window will be replaced with the
Advanced Simulation Mode Screen and return when you utilize the Probe Continuity Test, described in detail on the following page.
• F2 (Select) scrolls cursor upward through the selectable parameters.
• F3 (Select) scrolls cursor downward through the selectable parameters.
• F4 (Change+) changes parameter upward.
• F5 (Change-) changes parameter downward.
• PREV - will step back in the menu tree to the main menu.
• MORE is not used on this screen.
4-6 mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
Section 4. Installation & Operation
The SpO2 Simulation Menu, Advanced
Simulation Mode
Purpose of the SpO2 Simulator Menu's Advanced Simulation Mode: The advanced simulation features can be used for preventative maintenance, quality assurance, trouble shooting and repair of pulse oximeters and pre-purchase evaluations of pulse oximeters.
From the SpO2 Simulator Menu, Manual Mode, Press F1 (Advancd) to enter the SpO2 Simulator Menu,
Advanced Simulation Mode.
Oximeter
Nellcor
OXYGEN SAT
(SPO2 %)
100
–DataLog–
PULSE RATE
(BPM)
75
PulseMod
5.00%
Arrhythmia: Off
Motion Artifact: 0
Ambient Light
DC Level: 5
AC Level: 0
Frequency: Off
Standrd
F1
Select
F2
Select
F3
Change+
F4
Change-
F5 MORE PREV
From the SpO2 Simulator Menu, Advanced Simulation Mode, the following options are available:
• F1 (Standrd) returns SmartSat to standard SpO2 Simulation.
• F2 (Select) scrolls cursor upward through the selectable parameters.
• F3 (Select) scrolls cursor downward through the selectable parameters.
• F4 (Change+) changes parameter upward.
• F5 (Change-) changes parameter downward.
• MORE is not used on this screen.
• PREV will return the system to first screen in the SpO2 Simulation Mode.
mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
4-7
Section 4. Installation & Operation
The SpO2 Simulation Programmable Auto
Sequences Directory
Purpose of Programmable Auto Sequences Directory: Used on a routine basis for preventive maintenance and quality assurance, trouble shooting and repair of pulse oximeters. Each selectable brand of pulse oximeter is represented by an auto sequence test. These can be modified and saved for special testing needs.
From the SpO2 Simulator Menu, selecting F2 (AutoSeq) will place you in the Programmable Auto
Sequences Directory screen. From the Programmable Auto Sequences Directory, the following options are available:
Oximeter
Nellcor
OXYGEN SAT
(SPO2 %)
100
PULSE RATE
(BPM)
–DataLog–
75
PulseMod
5.00%
BCI : 58 - 100
CRITICARE
CSI SPOT
DATASCOPE
DATEX
HP
Programmable AutoSequence Directory
MASIMO
NELLCOR
NELL: 50 - 81
NELLOxiMAX
NONIN
NOVAMETRIX
OHMEDA
OHMD: 50 - 81
SENSORMEDX
TREND LOOP
4 POINTS
PR: 40 - 200
Select
F1
Select
F2 F3
Program
F4
Run
F5 MORE PREV
• F1 (Select) scrolls cursor upward through the auto sequences.
• F2 (Select) scrolls cursor downward through the auto sequences.
• F3 is not used on this screen.
• F4 (Program) modifies auto sequences.
• F5 (Run) selects auto sequence, then press F1 (Start/Stop) to start the auto sequence.
• MORE is not used on this screen.
• PREV - will return
Smart
Sat to the previous screen, pressing PREV multiple times will return
Smart
Sat to the Main Menu.
4-8 mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
Section 4. Installation & Operation
The SpO2 Simulation Programmable Auto
Sequences Directory, Program Mode
Purpose of Programmable Auto Sequences Directory, Program Mode: User can modify and save each auto sequence test for their specific testing requirements.
From the SpO2 Simulation Programmable Auto Sequences Directory, pressing F4 (Program) will place you in the Programmable Auto Sequences Directory, Program Mode screen.
Oximeter
Nellcor
OXYGEN SAT
(SPO2 %)
100
PULSE RATE
(BPM)
–DataLog–
75
PulseMod
5.00%
AutoSeq: Nellcor Oximeter: Nellcor
Step Time Mod Sp02 Rate
1
2
3
4
5
6
20s
20s
20s
20s
20s
20s
5.00
5.00
5.00
5.00
5.00
5.00
100 70
99 70
98 70
97 70
96 70
95 70
7
8
9
10
20s
20s
20s
20s
5.00
5.00
5.00
5.00
94 70
93 70
92 70
91 70
SelectMode: Step / (Use MORE to change)
Change Char
F1
Char
F2
Select
F3
Change+
F4
F5 MORE
PREV
From the Programmable Auto Sequences Screen, Program Mode, the following options are available:
• F1 (<Char) scrolls cursor upward through each character. F1 becomes (Select?) when the cursor is in oximeter:_______ or in the auotsequence itself.
• F2 (Char>) scrolls cursor downward through each character. F2 becomes (Select?) when the cursor is in oximeter:______ or in the autosequence itself.
• F3 (Select < >) scrolls cursor between.
• F4 (Change+) changes the highlighted character and field.
• F5 (Change-) selects auto sequence, then press F1 (Start/Stop) to start the auto sequence.
• MORE is not used on this screen.
• PREV - will return SmartSat to the previous screen, and save any changes made to the programmable autosequence.
mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
4-9
Section 4. Installation & Operation
The SpO2 Simulation Programmable Auto
Sequences Directory, Run Mode
Purpose of Programmable Auto Sequences Directory, Run Mode: Starts the selected autosequence test for their specific testing requirements.
Oximeter
Nellcor
OXYGEN SAT
(SPO2 %)
100
–DataLog–
PULSE RATE
(BPM)
75
PulseMod
5.00%
AutoSeq: Nellcor Oximeter: Nellcor
Step Time Mod Sp02 Rate
1
2
3
4
5
6
7
8
9
10
20s
20s
20s
20s
20s
20s
20s
20s
20s
20s
5.00 100
5.00 99
5.00
5.00
5.00
5.00
98
97
96
95
5.00 94
5.00 93
5.00 92
5.00 91
70
70
70
70
70
70
70
70
70
70
Start
F1 F2 F3 F4 F5 MORE PREV
From the SpO2 Simulation Programmable Auto Sequences Directory, select the desired autosequence and press F5 (Run).
From the Programmable Auto Sequences Directory, Run Mode, the following options are available:
• F1 (Start) starts the selected autosequence test. Press F1 (Stop) to stop test. This switch will toggle between Start/Stop.
• F2 not used in this screen.
• F3 not used in this screen.
• F4 not used in this screen.
• F5 is not used in this screen.
• MORE is not used on this screen.
• PREV - will return SmartSat to the previous screen. Note: You must stop the autosequence by pressing the F1 (Stop) key otherwise the autosequence will continue to run until completed. This allows the user to perform probe testing concurrently with simulation.
Note: When using autosequences, the programmed oximeter type will take precedence and change the oximeter selection displayed at the upper left when the test starts.
4-10 mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
Section 4. Installation & Operation
The Probe Continuity Test Menu
Purpose of Probe Continuity Test: Confirms proper electrical and insulation properties within the pulse oximeter probe. In an intact/normal probe the continuity trace will sweep across the screen within the
GOOD zone. If an open or short connection is detected the trace will shift in the appropriate direction.
When the probe is being tested, the cabling should be gently wiggled as a stress test to check for intermittent abnormal electrical connections. This is useful for intermittent problems, isolating the problems and ruling out human error.
From the main menu, Press F2(Probe-C) to enter the Probe Continuity Test screen. The PREV key will return the system to the main menu.
Oximeter
Nellcor
OXYGEN SAT
(SPO2 %)
100
–DataLog–
PULSE RATE
(BPM)
75
PulseMod
5.00%
Probe Continuity
L
E
D
Open
Good
Short
P
H
O
T
O
Open
Good
Short
SglSwp
Oximtr+
F1
Oximtr -
F2
SwpMode
F3
Center
F4
Reset
F5 MORE
PREV
From the Probe Continuity Test Menu, the following options are available:
• F1 (oximtr+) scrolls upward through the brands of oximeter probes
• F2 (oximtr-) scrolls downward through the brands of oximeter probes
• F3 (SwpMode) toggles between Single Sweep and Repetitive Sweep test modes. Single Sweep stops sweeping on any fault while Repetitive Sweep tests continuously.
• F4 (Center) Centers the baseline waveform on the Good levels on the display and displays the baseline
LED and PhotoDiode voltage drops.
• F5 - Reset will restart the trigger function.
• PREV - returns the user to the main menu.
• MORE - currently not utilized.
mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
4-11
Section 4. Installation & Operation
The Probe Sensitivity Test Menu
Purpose of Probe Sensitivity Test: Determines if the sensory diodes are receiving the appropriate signals. In some cases, cleaning the surface of the LED and sensor lens with a solvent solution will improve probe performance. on the following page, there are some reference values for the Probe Sensitivity Test.
From the main menu, press F3 (Probe-S) to enter the Probe Sensitivity Test Menu. The PREV key will return the system to the main menu.
Oximeter
Nellcor
R
A
T
I
O
R
I
R
E
D
Oximtr+
F1
Oximtr -
F2
OXYGEN SAT
(SPO2 %)
100
PULSE RATE
(BPM)
–DataLog–
75
PulseMod
5.00%
Probe Sensitivity
0
F3 F4 F5 MORE PREV
From the Probe Sensitivity Test menu, the following options are available:
• F1 (Oximtr+) scrolls upward through the brands of oximeter probes.
• F2 (Oximtr-) scrolls downward through the brands of oximeter probes
• F3 , F4 & F5 not currently utilized.
• PREV returns user to the main menu.
• MORE not used in this screen.
4-12 mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
Section 4. Installation & Operation
Probe Sensitivity Test: Reference Values
The values labeled "Typical" in the table below were obtained by averaging the readings obtained by performing the SmartSat's Probe Sensitivity test on a large number of good pulse oximeter probes. The values labeled "Typical Range" are values at which, when the "probe under test" measures outside this range, it should be considered suspect. Since the pulse oximeter manufacturers have thus far declined to provide absolute limits for these ranges, we can not positively state that probes that exceed these limits are "bad."
However, we can state that they deviate significantly from the "typical" probes of that make and model. In general, when evaluating probes using the Probe Sensitivity test, if you obtain a reading outside the limits, you should take into account other factors. For example, multiple readings (such as Red and Ratio) outside the limits or an out-of-limit reading on a probe that is old or looks worn, is probably an indication of a probe that may malfunction under certain clinical conditions.
Probe
Nellcor DS-100A
Ohmeda Clip Tip
Red
Typical
Red
Typical
Range
IR
Typical
158
168
>79
>168
262
268
IR
Typical
Range
>196
>244
Ratio
Typical
60
63
Ratio
Typical
Range
30 to 90
40 to 100 mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
4-13
Section 4. Installation & Operation
The Setup Menu
Allows configuration of Key Beep (on/off), selection of Remote Control or Datalog for the RS-232 port and enter information which will print on a datalogged test report.
Oximeter
Nellcor
OXYGEN SAT
(SPO2 %)
100
PULSE RATE
(BPM)
–DataLog–
75
PulseMod
5.00%
Key Beep: On
Serial Port: DataLog
Printing
Stored Printing: Off
Work Order #:
Oximeter # :
Date:
–
Tested By:
–02
Select
F1
Select
F2 F3
Change+
F4
Change -
F5 MORE
PREV
From the Setup Menu the following options are available:
• F1 (Select) scrolls cursor upward through the selectable parameters.
• F2 (Select) scrolls cursor downward through the selectable parameters.
• F3 is blank when Key Beep and Serial Port parameters are selected. F3 becomes F3 (Char) when Work
Order, Oximeter, Date and Tested By parameters are selected.
• F4 (Change+) changes parameter upward.
• F5 (Change-) changes parameter downward.
• MORE is not used on this screen.
• PREV will return user to the main menu.
4-14 mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
Section 4. Installation & Operation
The Battery Check Menu
Purpose of the SmartSat's Battery Check Menu: Displays SmartSat's battery voltage.
From the Main Menu, Press F5 (BatChk) to enter SmartSat's Battery Check Menu.
Oximeter
Nellcor
OXYGEN SAT
(SPO2 %)
100
–DataLog–
PULSE RATE
(BPM)
75
PulseMod
5.00%
Probe Continuity
Open
L
E
D
Good
Short
P
T
O
H
O
Open
Good
Short
SglSwp
SpO2s im
F1
Probe-C
F2
Bat:19.82V (19.00V=LoBat)
Probe-S Setup BatChck
F3 F4
F5 MORE
PREV
From the Battery Check Menu all Main Menu options are available:
• F1 is not used on this screen.
• F2 is not used on this screen.
• F3 is not used on this screen.
• F4 is not used on this screen.
• F5 (BatChck) displays current battery voltage. Pressing it will turn off/on the battery indicator.
• MORE returns user to the main menu.
• PREV returns user to the main menu.
Note:
1. When connected to the external power supply, the value displayed is the power supply voltage, not the battery voltage.
2. "Low Battery" indicator comes on at approximately 19V as the remaining battery life approaches 1 hour.
3. SmartSat will shut off when the battery discharges to approximately 16V.
mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
4-15
Section 4. Installation & Operation
4-16 mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
Section 5. Frequently Asked Questions
Q: How do I test my probes with the SmartSat?
A: Simply connect a Nellcor, BCI, Nonin or Ohmeda probe into the Nellcor or Ohmeda Probe Analyzer ports on the side of the SmartSat. For other brands of probes, use the appropriate Probe Analyzer Cable and connect it into the Ohmeda Probe Analyzer port. Then connect the probe to the Probe Analyzer cable to test the probe.
Q: Why does the SmartSat test the probe and oximeter independently?
A: During the extensive market research when developing SmartSat, we found that over 96% of all oximetry problems occur within the probe. SmartSat is a "True Test Standard" utilized by major pulse oximetry manufacturers for electrically testing the functional accuracy of pulse oximeters. With both a
SpO2 simulator and Probe Analyzer in one test system, problems are correctly identified and can be repaired. There is no guesswork involved.
Q: What types of probes can be tested?
A: All types of probes (except MRI probes) can be tested with SmartSat:
1. Adult size permanent probes
2. Adult size disposable probes
3. Neonate size permanent probes
4. Neonate size disposable probes
Q: How does the Probe Continuity Test work?
A: The Probe Continuity Test completely checks each probe for open, short, and intermittent failures. The probe can be tested correctly throughout its useful life cycle.
Q: I am using the Probe Sensitivity Test and when I open the finger probe or hold it towards the light, my readings are affected. Why does this happen?
A: When the probe is opened, it separates the LED's and the Photodiode paths. The farther the Photodiode is from the LED's, the less red and infrared light reaches the Photodiode, which affects the readings.
mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
5-1
Section 5. Frequently Asked Questions
Q: What pulse oximeters does SmartSat test?
A: SmartSat works with the following pulse oximeters; BCI, Criticare, Criticare SPOT, Datascope, Datex,
Hewlett-Packard, Masimo, Nellcor, Nihon Kohden, Nonin, Novametrix, Ohmeda and Sensormedics.
Q: How are the R-Curves obtained?
A: Our engineers obtained the information from and worked with each manufacturer to assure a "True Test
Standard" for testing pulse oximeters. We thank those manufacturers for their help. Because of our relationships with these manufacturers through non-disclosures and supplier agreements, we are assured future compatibility by these manufacturers using SmartSats for testing their pulse oximeters throughout their organizations.
5-2 mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
Section 6. Pulse Oximeter Compatibility Chart
The following manufacturers use Nellcor™ technology with their systems:
1.
Philips Medical Systems
2.
Atom Medical Corp.
3.
Baxter Healthcare Corp.
4.
Century Medical Inc.
5.
Colin
6.
GEMedical Services
7.
Welch Allyn
8.
Datascope
9.
Drager
10. Edentec
11. Fukuda Denshi
12. Ivy Biomedical Systems
13. Marquette (Eagle)
14. MDE
15. Mennen Medical
16. Drager
17. Respiroinics
18. CAS Medical Systems
19. Zoll
20. Siemens
21. Sleeptrace/Areca Science
22. SpaceLabs
23. Synetics
24. Schiller
The following manufacturers use Masimo® technology with their systems:
1.
2.
3.
4.
4.
6.
7.
8.
9.
Ohmeda-Medical
Drager
Welch Allyn
Atom Medical
Alaris Medical Systems
Bitmos
Invivo Research
MDE
Mennen Medical
10. Datascope
11. GE Medical Systems
12. Zoll
13. Colin
14. Allegiance
15. Critikon
16. Ivy Biomedical Systems
17. Medtronic
18. Respironics
19. SS Corpulus
20. Getemed
21. Graseby
22. Kohken Medical
23. Mindray
24. Schiller
25. Stephan
26. CAS Medical Systems
27. Nascor Neonatal
28. Hill-Rom mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
6-1
Section 6. Pulse Oximeter Compatibility Chart
6-2 mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
Section 7: Remote Control, Version 0.4
Remote control of the SmartSat‘ by a host computer is possible via an RS-232 serial port located on its right panel. This RS-232 port, a 9-pin female D-shell, is configured as a "DCE," allowing direct connection to the serial port on IBM-compatible computers. Therefore, to connect the SmartSat to an IBM-compatible PC, a standard cable, rather than a null modem cable, should be used. (A CGA video monitor extension cable, readily available in computer stores and mail-order catalogs, can be used. Alternatively, mtk can supply the appropriate cable.)
The serial port on the host computer should be configured with the following communications parameters:
Baud Rate:
Data Bits:
Stop Bits:
Parity:
1200 baud
8
1
None
The SmartSat’s communication protocol is essentially an all-ASCII, all-uppercase format. (The only exceptions are messages that contain waveform datapoints in binary code.) An ASCII format facilitates using popular PC communications software such as Windows Terminal, ProComm or Crosstalk as a
“control console” to interact with the SmartSat. Before developing the remote control software for use in your application, it is recommended that the programmer familiarize themselves with the communications protocol using PC communications software.
To send remote control commands using the Windows 3.11 Terminal program:
• Select the -Communications option under the Settings pulldown menu and set the following:
Baud Rate:
Data Bits:
1200 baud
8
Stop Bits: 1
Parity: None
• Then select the -Terminal Preferences option under the Settings pulldown menu and set the following:
Enable “Local Echo” under “Terminal Modes”
Enable “Outbound” under “CR->CR/LF”
Communication between the SmartSat and the host device consists of two categories:
1) Command messages sent by the host to the SmartSat
2) Response messages sent by the SmartSat to the host
The following pages describe the command messages and response messages in detail.
Please note that if the terminal is receiving repeated strings of “SRP” it is because the SmartSat RS-232 port is set to “DataLog” not “Remote Control” This can be changed via the “Advanced” settings on the SmartSat.
mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
7-1
Section 7. Remote Control, Version 0.3
Generic Command Message Format
[SS] [Command Character] [Data Characters] <cr><lf>
Optional Termination
(ASCII Line Feed)
Termination Character
(ASCII Carriage Return)
Data Field
Command Field
Preamble
Note: Brackets are for documentation only and are not part of the command format.
As shown above, host command messages consist of four (4) fields:
1. Preamble: [SS]
2. Command Field: a single uppercase letter (described below)
3. Data Field: 0 or more bytes (command dependent)
4. Termination Character: <cr> (i.e., hexadecimal “0d”, the ASCII carriage return control code)
5. Optional Termination Character: <lf> (i.e., hexadecimal “0f”, the ASCII line feed control code); Note use this character to improve readability of commands and responses when controlling the SmartSat using PC communications software.
A checksum is not used because it is awkward to generate and transmit checksums with an ASCII terminal.
Message integrity checking is achieved via a structured message format; limit tests for all transmitted data; and command and data acknowledgment.
See the attached table for a list of commands and the associated data field contents.
7-2 mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
Section 7. Remote Control, Version 0.3
Generic Response Message Format
<cr><lf>[SyntaxError]<cr><lf>
As The SmartSat receives and parses the incoming command message, if it encounters an illegal command syntax, it will generate a "SyntaxError" response.
[DataError]<cr><lf>
If the SmartSat encounters an illegal data value, it will generate a "DataError" response.
[SS] [Command Character] [=] [Data Characters] <cr><lf>
After receipt of a valid command and valid data, and after the SmartSat has successfully executed the command, it will acknowledge that fact to the host by echoing the preamble and command field followed by an "=" sign, the data field and the termination character. mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
7-3
Section 7. Remote Control, Version 0.3
Command
K
S
R
O
A
Description
Locks front panel keypad
Sets SpO
2 value
Sets Pulse Rate value
Sets Oximeter Type
Sets Pulse Modulation value scaled at 001=0.05%
Data Field Range
0 = Unlock
1 = Lock
000 to 100
Example
S S K 0 <cr>
S S K 1 <cr>
S S S 0 9 1 <cr>
020 to 300 S S R 0 7 5 <cr>
B=BCI
C=Criticare
P=CSI Spot
D=Datascope
X=Datex
H=HP
M=Masimo
N=Nellcor
Q=N. OxiMax
K=NihonKohden
Z=Nonin
V=Novametrix
O=Ohmeda
S=Sensormedics
S S o B <cr>
000 to 200 S S A 1 1 0 <cr>
Max setting is 200=10.00%
D Sets DC Level of Ambient
Light
000 to 255 S S D 1 0 0 <cr>
7-4 mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
Section 7. Remote Control, Version 0.3
Reserved commands for future use:
Command
T
F
Description
IR Tissue Transmissivity
Red Tissue Transmissivity is set to 0.5 IR Tissue
Transmissivity
Sets Frequency of Ambient
Light (Flicker Frequency)
L Sets AC Level of Ambient
Light (Flicker Level)
Data Field Range
000 to 255
0=Off
1= 60 Hz
2=120Hz
3=121Hz
4= 50 Hz
5=100Hz
6=101Hz
0 to 255
Example
not yet implemented not yet implemented not yet implemented
mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
7-5
Section 7. Remote Control, Version 0.3
SmartSat RS-232 Serial Communications Pin Assignments
5 4 3 2 1
9 8 7 6
9 Pin D-Type Female Connector
Pin Signal
1 (Not Used)
2 Rx (Receive Data, Input to SmartSat)
3 Tx (Transmit Data, Output from SmartSat)
4 DTR (Data Terminal Ready, Input to SmartSat)
5 GND (Signal Ground)
6 DSR (Data Set Ready, Output from SmartSat)
7 (Not Used)
8 DSR (Data Set Ready, Output from SmartSat)
9 (Not Used) mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de
mtk Peter Kron GmbH Medical Test Devices, Software & Services
Zossener Straße 41 10961 Berlin / Germany Tel.: +49 (0)30 / 69 81 88 - 40 Fax: +49 (0)30 69 81 88 - 49
Email: [email protected] www.mtk-biomed.de