TRANE BCI-C BACnet Communication Interface for Chiller Integration Guide
PDF
নথি
বিজ্ঞাপন
বিজ্ঞাপন
Integration Guide BACnet™ Communication Interface for Chiller (BCI-C) for RTWD, RTUD, RTHD, RTAC, CGAM/CXAM, and CGWN/ CCUN SAFETY WARNING Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. May 2011 BAS-SVP05E-E4 Copyright © 2011 Trane. All rights reserved. This document and the information in it are the property of Trane and may not be used or reproduced in whole or in part, without the written permission of Trane. Trane reserves the right to revise this publication at any time and to make changes to its content without obligation to notify any person of such revision or change. Trademarks Trane and its logo are trademarks of Trane in the United States and other countries. All trademarks referenced in this document are the trademarks of their respective owners. Warnings, Cautions, and Notices Warnings, cautions, and notices are provided in appropriate places throughout this document: WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION: Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. It could also be used to alert against unsafe practices. NOTICE: Indicates a situation that could result in equipment or propertydamage-only accidents. 2 BAS-SVP05E-E4 • BCI-C Integration Guide Table of Contents Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 BACnet Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Reference Flowchart to Setup the BCI-C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Required Software and Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Best Practice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Configuring the BCI-C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Using the BACnet Setup Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Using Tracer TU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Understanding the MAC Address and BACnet Device ID . . . . . . . . . . . . . . . . .9 MAC Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 BACnet Device ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Rotary Dial Address Settings for Non-Trane SC Systems . . . . . . . . . . . .10 What To Do After Adding Options or Equipment to the Unit . . . . . . . . . . . . .10 Clearing the Controller and Restoring Factory Defaults to the BCI-C . . .10 Updating the Application Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 Managing Device Units on the Controller Units Screen . . . . . . . . . . . . . . . . .11 Rotary Switches and LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Rotary Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 LEDs Description, Behavior, and Troubleshooting . . . . . . . . . . . . . . . . . . . . .13 BACnet Data Points and Configuration Property Definitions . . . . . . . . . . . . . . . .15 BACnet Protocol Implementation Conformance Statement (PICS) . . . . . . . .15 Standardized Device Profile (Annex L) . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Interoperability Building Blocks (Annex K) . . . . . . . . . . . . . . . . . . . . . . . . .15 Segmentation Capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Object Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 BACnet Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Data Link Layer Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Device Address Binding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Networking Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Character Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Object and Diagnostic Data Points and Corresponding Chiller Models . . . . . .21 BCI-C Alarming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 Additional Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 BAS-SVP05E-E4 • BCI-C Integration Guide 3 Overview The BACnet™ Communication Interface for Chillers (BCI-C) is comprised of a Tracer™ UC400 controller with interface software. It is a non-programmable communications module that allows heating, ventilation, and air-conditioning (HVAC) equipment to communicate on a BACnet communications network. This guide provides: • A brief overview of the BACnet protocol • Flowchart to setup the BCI-C • Getting started • Configuring the BCI-C • A explanation of the BCI-C device rotary switches and LEDs • Data point configuration property definitions • Tables listing object data points • Additional resources • A glossary of terms Note: Users of this guide should have basic knowledge of BACnet protocol. For more detailed information about this protocol, visit the company web site listed under “Additional Resources,” p. 31. BACnet Protocol The Building Automation and Control Network (BACnet and ANSI/ASHRAE Standard 135-2004) protocol is a standard that allows building automation systems or components from different manufacturers to share information and control functions. BACnet provides building owners the capability to connect various types of building control systems or subsystems together for a variety of reasons. In addition, multiple vendors can use this protocol to share information for monitoring and supervisory control between systems and devices in a multi-vendor interconnected system. The BACnet protocol identifies standard objects (data points) called BACnet objects. Each object has a defined list of properties that provide information about that object. BACnet also defines a number of standard application services that are used to access data and manipulate these objects and provides a client/server communication between devices. For more information on BACnet protocol, refer to “Additional Resources,” p. 31. BACnet Testing Laboratory (BTL) Certification The BCI-C supports the BACnet communication protocol and has been designed to meet the requirements of the application-specific control profile. For more details, refer to the BTL web site at www.bacnetassociation.org. 4 BAS-SVP05E-E4 • BCI-C Integration Guide Reference Flowchart to Setup the BCI-C Use the following reference flowchart as a best practice when setting up the BCI-C. The sections that follow describe this flowchart in more detail. Getting Started Install Hardware (Refer to the BCI-C Field Kit Installation Guide [RF-SVN02]) Setup MAC Address (Refer to the subsection, “Understanding the MAC Address and BACnet Device ID,” p. 9) Set Device ID, Baud Rate, and Engineering Units (Refer to “Configuring the BCI-C,” p. 6) Set Analog Ouput Values to Control Chiller, If Desired (Refer to Table 3, p. 21) BAS-SVP05E-E4 • BCI-C Integration Guide 5 Getting Started This section describes the necessary software, tools, and initial tasks that are required for a successful integration. Required Software and Tools The following are required: • Tracer™ BACnet Setup Tool OR Tracer™ TU Service Tool, version 6.0 or higher • A USB cable (for use with Tracer TU) • A 1/8 inch (3 mm) flat-bladed screwdriver Best Practice It is best practice to perform the following tasks in the order in which they are listed: • Install hardware. • Set device addresses on the BCI-C rotary switches (see following section). • Select either wired or wireless communication using the link select switch on the BCI-C. • Configure the BCI-C by using either the Tracer BACnet Setup Tool (BST) or Tracer TU. – The default baud rate is 76,800 bps. – The default software device ID is the MAC address. – The device units do not have defaults; the BST or Tracer TU will display the device units of the controller to which it is connected. Configuring the BCI-C The BCI-C can be configured using either the Tracer™ BACnet Setup Tool or the Tracer™ TU service tool. Note: The BCI-C controller is configured from the factory for use with a typical Tracer SC based systems. Additional configuration is necessary if a baud rate, device ID, or engineering units are needed with the BACnet system being used. Additionally, the BCI-C self-configures its BACnet points to match the unit type upon initial power-up. Using the BACnet Setup Tool This section describes how to configure the BCI-C controller using the Tracer BACnet Setup Tool. Online help is available by clicking the help icon located in upper right portion of the screen. 1. Open the Tracer BACnet Setup Tool and the Controller Settings screen appears (Figure 1). 2. In the Protocol and Controller Units sections, change or keep the default settings for the baud rate, software device ID, and the device units. 3. Click Save. 6 BAS-SVP05E-E4 • BCI-C Integration Guide Configuring the BCI-C Figure 1. BACnet Setup Tool Controller Settings screen Illustration is an example if the unit was connected to a UC400. BAS-SVP05E-E4 • BCI-C Integration Guide 7 Configuring the BCI-C Using Tracer TU This section describes how to first connect to the Tracer TU software and then configure the BCI-C controller. If Tracer TU is not installed, refer to the “Tracer TU Service Tool Getting Started Guide” (TTU-SVN02). Tracer TU software, Version 6.0 or higher, is required. To connect to Tracer TU: 1. Connect the USB cable directly from the laptop to the BCI-C, or to an equipment control panel USB port connected to the controller. Important: If using a PC with multiple USB ports, connect by using the same process outlined below for the same piece of equipment. This is normal operation. Observe existing USB standards for cable length. (For more information go to informational Web sites, such as http://www.USB.org.) 2. Click either the Tracer TU desktop icon or the Tracer TU program item in the Tracer TU group on the Start menu. The Tracer TU splash screen briefly appears followed by the Connect dialog box. Figure 2. Connect dialog box 3. Select the Direct Connection (USB cable) radio button, if it is not already selected. 4. Click the Connect button and the Unit Summary page will appear after successful connection. To configure the BCI-C controller: 1. Select the Controller Settings Utility tab from the vertical tab set located on the right side of the TU window. Note: The content of this screen is based on the type of controller that is connected and the system protocol used to communicate with the controller. 2. Enter a meaningful name for the controller. 3. Click the Controller Units expanding box label to display its contents. 4. Select the preferred units of measure for data communicated across the BACnet link. 5. Click the Protocol expanding box heading to display its contents. 6. Select the preferred Baud Rate in the drop-down list box. 8 BAS-SVP05E-E4 • BCI-C Integration Guide Configuring the BCI-C 7. If a software Device ID is required, check the Use Software Device ID box and enter a BACnet Device ID. 8. Click Save. Understanding the MAC Address and BACnet Device ID MAC Address The MAC address is the rotary dial address. For Trane systems, this address must be between 1 and 127. Although “0,0,0,” is a valid BACnet address, Trane reserves this address for the Tracer SC controller. All devices on the BACnet MS/TP link must be unique. For non-Trane SC systems, see “Rotary Dial Address Settings for Non-Trane SC Systems,” p. 10. BACnet Device ID Tracer SC uses the rotary dial settings (MAC address) to create the BACnet device ID. The Tracer SC adds an SC rotary dial address and a link number to artificially create a unique BACnet Device ID for each node. To manually set rotary dial settings, refer to the section, “Rotary Switches and LEDs,” p. 12. Figure 3 shows how Tracer TU displays the rotary dial settings and the resulting BACnet device ID: • The rotary dials on the BCI-C are set to 30 (0,3,0), which is also the MAC address. • The Tracer SC created a BACnet device ID of 101030. • The Tracer SC address is “0,1,0”. • The BCI-C is installed on link 1. Figure 3. Example showing rotary dial settings and BACnet device ID MAC address BACnet device ID BAS-SVP05E-E4 • BCI-C Integration Guide 9 Configuring the BCI-C Rotary Dial Address Settings for Non-Trane SC Systems For non-Trane SC systems, the Max Master value must be greater than the unique address settings from the rotary dials. Although 999 is possible from the dials, the maximum allowed number by BACnet is 127. The Max Master is not adjustable in Trane SC systems. For example, if the MAC address is 101 and the front-end system has a Max Master value of 100, the device will not be discovered. Many systems have a minimum BACnet Device ID value. Ensure that the Device ID is greater than this value. What To Do After Adding Options or Equipment to the Unit Restoring the BCI-C controller to factory defaults is necessary if the unit setup has changed after the initial self-configuration process. This process is called clearing the controller. For example, an economizer is added to the machine after the initial installation. In order for the BCI-C controller to recognize the economizer, it must be restored to factory defaults. The BCI-C controller self-configures upon initial power-up to match the connected equipment type. This configuration is then permanently stored in the memory of the controller. Through this process, the controller generates the correct list of BACnet points. Clearing the Controller and Restoring Factory Defaults to the BCI-C Clearing the controller is necessary to collect equipment information and reinstall the configuration. Using the BACnet Setup Tool to Clear the Controller and Restore to Factory Defaults 1. Navigate to the Controller Settings screen. 2. Click within the light gray area at the bottom left of the screen just above the Connected indicator. The Clear Controller button appears at the top right of the screen. 3. Click Clear Controller and amessage box appears stating that the configuration will be reset (deleted). 4. Click OK. When the controller is cleared, the Select Device Units message box appears. 5. Click OK and then expand the Controller Units box on the Controller Settings screen. 6. Select the units (SI, IP, or Custom). The controller defaults to Custom after clearing the controller. To use Custom, ensure that all unit options are set correctly. 7. Click Save. Using Tracer TU to Clear the Controller and Restore to Factory Defaults 1. Establish the connection between Tracer TU and the BCI-C controller. 2. Select the Controller Settings Utility tab from the vertical tab set located on the right side of the TU window. 3. On the controller settings page, there is a gray bar at the bottom with the Save/Cancel buttons. Move the cursor near the left edge of the gray bar, keeping the cursor inside the bar; click on this area. A Clear Controller button will appear in the upper right portion of the screen display. 4. Click the Clear Controller button and a pop-up window will appear with a message that asks for confirmation to reset the device. Click Yes. 5. A pop-up window will appear confirming that the controller has been reset and that the controller will be restarted. Click OK. The BCI-C controller is restored to its factory default state after it restarts. 10 BAS-SVP05E-E4 • BCI-C Integration Guide Configuring the BCI-C 6. Follow the steps in “Using Tracer TU,” p. 8 to reconfigure the BCI-C controller. Updating the Application Code The application code in the BCI-C controller can be upgraded in the field by using Tracer TU. Follow the instructions in Tracer TU to upgrade the application code. Managing Device Units on the Controller Units Screen The BCI-C device units can be viewed and managed on the Controller Units screen from either the BACnet Setup Tool or Tracer TU. When the BCI-C first powers up, or after the controller has been cleared, a list of points (the role document) is created from the information supplied to the BCI-C from the CH530 module through the Modbus link. Note: The BCI-C creates the role document immediately (often within one second). Immediately after the points are created, the device units are set and saved and appear on the Controller Units screen. The values that correspond to the device units are set to default to SI values. In some cases, the Custom radio button may be selected; however, the device units will still default to SI. Best Practice: When using Tracer TU to change the Device Units to IP by clearing the controller, it is best to either unplug the Modbus cable to the BCI-C, or to power down the entire unit (the BCIC). By doing this, the BCI-C will not see Modbus traffic. This method will enable the Device Units radio button selection, which allows you to make changes. BAS-SVP05E-E4 • BCI-C Integration Guide 11 Rotary Switches and LEDs This section provides information about the BCI-C rotary switches and LED displays. Rotary Switches There are three rotary switches on the front of the BCI-C device that are used to define a three-digit address when the BCI-C is installed on a BACnet communications network. The three-digit address setting is the BACnet MAC address. Note: All devices are MSTP masters with valid MAC addresses of 001 to 127 for BACnet. Figure 4. Setting rotary switches Before After ADDRESS 90 1 7 8 7 8 90 1 2 3 2 3 2 3 7 8 90 1 4 56 4 56 4 56 x100 x10 x1 Example of before and after setting addresses Each device on the BACnet/ MSTP link must have a unique rotary switch setting, otherwise, communication problems will occur. 78 901 23 Use a 1/8 inch flathead screwdriver to set rotary switches. 456 Important: Note: For details on setting the baud rate, BACnet Device ID, and units of measure, refer to the section, Configuring the BCI-C in the BACnet Communication Interface (BCI-C) Field Kit Installation Guide, RF-SVN02. 12 BAS-SVP05E-E4 • BCI-C Integration Guide Rotary Switches and LEDs LEDs Description, Behavior, and Troubleshooting There are 15 LEDs on the front of the BCI-C unit. However, LEDs BO1 through BO9 are not used for the BCI-C controller. Figure 2 shows the locations of each LED. The following table provides a description of each LED activity, an indication or troubleshooting tips for each, and any notes. Figure 5. LED locations Marquee LED LINK IMC TX RX SERVICE Table 1. LED Activities and Troubleshooting Tips LED Name Activities Indication or Troubleshooting Tip (Denoted in Bullets) Notes Shows solid green when the unit is Indicates normal operation powered and no problems exist Shows solid red when the unit is powered, but represents low power or a malfunction Marquee LED • If low power; could be under voltage or the microprocessor has malfunction. • If malfunction; un-power and then re-power unit to bring the device back up to normal operation. Alarm; when an alarm is triggered, for example, when a point goes Shows blinking red when an alarm into fault condition because of point failure or there is an exists indication of a custom alarm in TGP2 Indicates power is OFF or there is a malfunction LED not lit • OFF or malfunction; cycle the power. BAS-SVP05E-E4 • BCI-C Integration Guide 13 Rotary Switches and LEDs Table 1. LED Activities and Troubleshooting Tips LED Name Activities TX blinks green RX blinks yellow Link and IMC Indication or Troubleshooting Tip (Denoted in Bullets) Blinks at the data transfer rate when the unit transfers data to other devices on the link Blinks at the data transfer rate when the unit receives data from other devices on the link • ON solid yellow; indicates there is reverse polarity Indicates that the controller is not detecting communication LED not lit • Not lit; cycle the power to reestablish communication Shows solid green Service Blinks green Indicates someone has pressed the LED, the controller is not operating normally, or TechView is in Binding View and commanding to the BCI-C to turn On the LED Indicates controllers is not accessing application software • Restore; using TU service tool LED not lit Binary 01 to Binary 09 14 Indicates controller is operating normally Notes TX LED: Regardless of connectivity or not, this LED will constantly blink as it continually looks for devices to communicate to. LED not lit: Determine if, for example, a Tracer™ SC or BACnet device is trying to talk to the controller or if it is capable of talking to the controller. Also determine if the communication status shows down all of the time. Press and hold during power up to place controller into boot code or press and hold for a count of approximately 10 seconds to clear the Device ID. What is Boot Code? When the UC400 is placed into boot code, the system will not run any applications such as trending, scheduling, and TGP2 runtime. Not Used BAS-SVP05E-E4 • BCI-C Integration Guide BACnet Data Points and Configuration Property Definitions The BCI-C device allows certain models of Trane chillers with CH530 controls to communicate with BACnet systems and devices using BACnet MS/TP. This section includes information about: • BACnet protocol implementation conformance statement (PICS) • Object types: descriptions and configuration (refer to Table 2, p. 17) • BACnet protocol: data link layers, device address binding, networking options, and character sets • Object data points and configurations BACnet Protocol Implementation Conformance Statement (PICS) Standardized Device Profile (Annex L) Profile Description Supported Profile BACnet Advanced Application Controller (B-AAC) BACnet Application Specific Controller (B-ASC) 9 BACnet Building Controller (B-BC) BACnet Operator Workstation (B-OWS) BACnet Smart Actuator (B-SA) BACnet Smart Sensor (B-SS) Interoperability Building Blocks (Annex K) Data Sharing Description Supported BIBB Data Sharing-COV-B (DS-COV-B) Data Sharing-ReadProperty-A (DS-RP-A) 9 Data Sharing-ReadProperty-B (DS-RP-B) 9 Data Sharing-ReadPropertyMultiple-B (DS-RPM-B) 9 Data Sharing-WriteProperty-A (DS-WP-A) 9 Data Sharing-WriteProperty-B (DS-WP-B) 9 Data Sharing-WritePropertyMultiple-B (DS-WPM-B) 9 Alarm and Event Management Description Supported BIBB Alarm and Event-ACKI-B (AE-ACK-B) 9 Alarm and Event-Alarm Summary-B (AE-ASUM-B) 9 Alarm and Event-Enrollment Summary-B (AE-ESUM-B) 9 Alarm and Event-Information-B (AE-INFO-B) 9 Alarm and Event-Notification Internal-B (AE-N-I-B) 9 Trending Description Trending-Automated Trend Retrieval-B (T-ATR-B) BAS-SVP05E-E4 • BCI-C Integration Guide Supported BIBB 9 15 BACnet Data Points and Configuration Property Definitions Trending-viewing and Modifying Trends Internal-B (T-VMT-I-B) Device Management Description 9 Supported BIBB Device Management-Backup and Restore-B (DM-BR-B) 9 Device Management-Device Communication Control-B (DM-DCC-B) 9 Device Management-Dynamic Device Binding-A (DM-DDB-A) 9 Device Management-Dynamic Device Binding-B (DM-DDB-B) 9 Device Management-Dynamic Object Binding-B (DM-DOB-B) 9 Device Management-List Manipulation-B (DM-LM-B) 9 Device Management-Object Creation and Deletion-B (DM-OCD-B) 9 Device Management-Private Transfer-A (DM-PT-A) 9 Device Management-Private Transfer-B (DM-PT-B) 9 Device Management-Reinitialize Device-B (DM-RD-B) 9 Device Management-TimeSynchronization-B (DM-TS-B) 9 Segmentation Capability Segmentation Description Segmented Requests/ Window Size: 1 Segmented Responses/ Window Size: 1 16 Supported Segment 9 9 BAS-SVP05E-E4 • BCI-C Integration Guide BACnet Data Points and Configuration Property Definitions Object Types Table 2. Object Type Descriptions and configurations Written(a) Ability to Delete Required Properties Read Properties Analog Input • • • • • • • • Object_Identifier Object_Name Object_Type Present_Value Status_Flags Event_State Out_Of_Service Units • • • • • • • • • • • • • • • • Object_Name Description Out_Of_Service Present_Value Reliability Min_Pres_Value Max_Pres_Value COV_Increment Time_Delay Notification_Class High_Limit Low_Limit Deadband Limit_Enable Event_Enable Notify_Type • • • • • • • • • • • • • • • Description Reliability Min_Pres_Value Max_Pres_Value COV_Increment Time_Delay Notification _Class High_Limit Low_Limit Deadband Limit_Enable Event_Enable Acked_Transitions Notify_Type Event_Time_Stamps Yes Yes, only user created objects Analog Output • • • • • • • • • • Object_Identifier Object_Name Object_Type Present_Value Status_Flags Event_State Out_Of_Service Units Priority_Array Relinquish_Default • • • • • • • • • • • • • • • • • Object_Name Description Out_Of_Service Present_Value Reliability Min_Pres_Value Max_Pres_Value Relinquish_Default COV_Increment Time_Delay Notification_Class High_Limit Low_Limit Deadband Limit_Enable Event_Enable Notify_Type • • • • • • • • • • • • • • • Description Reliability Min_Pres-Value Max_Pres_Value COV_Increment Time_Delay Notification _Class High_Limit Low_Limit Deadband Limit_Enable Event_Enable Acked_Transitions Notify_Type Event_Time_Stamps Yes Yes, only user created objects Analog Value • • • • • • • • Object_Identifier Object_Name Object_Type Present_Value Status_Flags Event_State Out_Of_Service Units • • • • • • • • • • • • • • • Object_Name Description Out_Of_Service Present_Value Reliability Relinquish_Default COV_Increment Time_Delay Notification_Class High_Limit Low_Limit Deadband Limit_Enable Event_Enable Notify_Type • • • • • • • • • • • • • • • Description Reliability Priority_Array Relinquish_Default COV_Increment Time_Delay Notification_Class High_Limit Low_Limit Deadband Limit_Enable Event_Enable Acked_Transitions Notify_Type Event_Time_Stamps Yes Yes, only user created objects Binary Input • • • • • • • • Object_Identifier Object_Name Object_Type Present_Value Status_Flags Event_State Out_Of_Service Polarity • • • • • • • • • • • • • • • Object_Name Description Out_Of_Service Inactive_Text Active_Text Present_Value Reliability Change_Of_State_Count Elapsed_Active_Time Time_Delay Notification_Class Alarm_Value Event_Enable Acked_Transitions Notify_Type • • • • • • • • • • • • • • • • Description Inactive_Text Active_Text Change_Of_State_Time Change_Of_State_Count Time_Of_State_Count_Reset Elapsed_Active_Time Time_Of_Active_Time_Reset Time_Delay Notification_Class Alarm_Value Event_Enable Acked_Transitions Notify_Type Event_Time_Stamps Reliability Yes Yes, only user created objects BAS-SVP05E-E4 • BCI-C Integration Guide Optional Properties Read Ability to Create 17 BACnet Data Points and Configuration Property Definitions Table 2. Object Type Descriptions and configurations (continued) Written(a) Ability to Delete Required Properties Read Properties Binary Output • • • • • • • • • • Object_Identifier Object_Name Object_Type Present_Value Status_Flags Event_State Out_Of_Service Polarity Priority_Array Relinquish_Default • • • • • • • • • • • • • • • • • Object_Name Description Out_Of_Service Inactive_Text Active_Text Present_Value Reliability Change_Of_State_Count Elapsed_Active_Time Minimum_On_Time Minimum_Off_Time Relinquish_Default Time_Delay Notification_Class Event_Enable Acked_Transitions Notify_Type • • • • • • • • • • • • • • • • • • Description Inactive_Text Active_Text Change_Of_State_Time Change_Of_State_Count Time_Of_State_Count_Reset Elapsed_Active_Time Time_Of_Active_Time_Reset Minimum_On_Time Minimum_Off_Time Time_Delay Notification_Class Feedback_Value Event_Enable Acked_Transitions Notify_Type Event_Time_Stamps Reliability Yes Yes, only user created objects Binary Value • • • • • • • Object_Identifier Object_Name Object_Type Present_Value Status_Flags Event_State Out_Of_Service • • • • • • • • • • • • • • • • • • Object_Name Description Out_Of_Service Inactive_Text Active_Text Present_Value Reliability Change_Of_State_Count Elapsed_Active_Time Minimum_On_Time Minimum_Off_Time Relinquish_Default Time_Delay Notification_Class Alarm_Value Event_Enable Acked_Transitions Notify_Type • • • • • • • • • • • • • • • • • • • • Description Inactive_Text Active_Text Change_Of_State_Time Change_Of_State_Count Time_Of_State_Count_Reset Elapsed_Active_Time Time_Of_Active_Time_Reset Priority_Array Relinquish_Default Minimum_On_Time Minimum_Off_Time Time_Delay Notification_Class Alarm_Value Event_Enable Acked_Transitions Notify_Type Event_Time_Stamps Reliability Yes Yes, only user created objects • • • • • • • Object_Name Location Description APDU_Segment_Timeout APDU_Timeout Number_Of_APDU_Retries Backup_Failure_Timeout • • • • • • • • • • • • Location Description Max_Segments_Accepted APDU_Segment_Timeout Max_Master Max_Info_Frames Local_Time Local_Date Configuration_Files Last_Restore_Time Backup_Failure_Timeout Active_COV_Subscriptions None None • • • • • • • Object_Identifier Object_Name Object_Type System_Status Vendor_Name Vendor_Identifier Model_Name Firmware_Revision Application_Software_Version Protocol_Version Protocol_Revision Protocol_Services_Supported Protocol_Object_Types_Supporte d Object_List Max_APDU_Length_Accepted Segmentation_Supported APDU_Timeout Number_Of_APDU_Retries Device_Address_Binding Database_Revision • • • • • • • • • • • • Object_Identifier Object_Name Object_Type Event_Type Notify_Type Event_Parameters Object_Property_Reference Event_State Event_Enable Acked_Transitions Notification_Class Event_Time_Stamps • • • • • • Object_Name Notify_Type Event_Parameters Object_Property_Reference Event_Enable Notification_Class • None Yes Yes, only user created objects • Polarity Device Event Enrollment Object 18 • • • • • • • • • • • • • Optional Properties Read Ability to Create BAS-SVP05E-E4 • BCI-C Integration Guide BACnet Data Points and Configuration Property Definitions Table 2. Descriptions and configurations (continued) Object Type Written(a) Optional Properties Read Ability to Create Ability to Delete Required Properties Read Properties Multistate Input • • • • • • • • Object_Identifier Object_Name Object_Type Present_Value Status_Flags Event_State Out_Of_Service Number_Of_States • • • • • • • • • • • • Object_Name Description State_Text Out_Of_Service Present_Value Reliability Time_Delay Notification_Class Alarm_Values Fault_Values Event_Enable Notify_Type • • • • • • • • • • State_Text Reliability Time_Delay Notification_Class Alarm_Values Fault_Values Event_Enable Acked_Transitions Notify_Type Event_Time_Stamps Yes Yes, only user created objects Multistate Output • • • • • • • • • • Object_Identifier Object_Name Object_Type Present_Value Status_Flags Event_State Out_Of_Service Number_Of_States Priority_Array Relinquish Default • • • • • • • • • • Object_Name Description State_Text Out_Of_Service Present_Value Reliability Time_Delay Notification_Class Event_Enable Notify_Type • • • • • • • • • • State_Text Reliability Relinquish_Default Time_Delay Notification_Class Feedback_Values Event_Enable Acked_Transitions Notify_Type Event_Time_Stamps Yes Yes, only user created objects Multistate Value • • • • • • • • Object_Identifier Object_Name Object_Type Present_Value Status_Flags Event_State Out_Of_Service Number_Of_States • • • • • • • • • • • • • • Object_Name Description State_Text Out_Of_Service Present_Value Reliability Priority_Array Relinquish_Default Time_Delay Notification_Class Alarm_Values Fault_Values Event_Enable Notify_Type • • • • • • • • • • • State_Text Reliability Relinquish_Default Time_Delay Notification_Class Alarm_Values Fault_Values Event_Enable Acked_Transitions Notify_Type Event_Time_Stamps Yes Yes, only user created objects Notification Class • • • • • • • Object_Identifier Object_Name Object_Type Notification_Class Priority Ack_Required Recipient_List • • • • Object_Name Priority Ack_Required Recipient_List None Yes Yes, only user created objects Trend • • • • • • • • • • Object_Identifier Object_Name Object_Type Log_Enable Stop_When_Full Buffer_Size Log_Buffer Record_Count Total_Record_Count Event_State • • • • • • • • • • • • • • Object_Name Log_Enable Start_Time Stop_Time Log_DeviceObjectProperty Log_Interval Stop_When_Full Buffer_Size Log_Buffer Record_Count Notification_Threshold Notification_Class Event_Enable Notify_Type • • • • • • • • • • • • • Yes Yes, only user created objects Start_Time Stop_Time Log_DeviceObjectProperty Log_Interval Stop_When_Full Buffer_Size Notification_Threshold Records_Since_Notification Last_Notify_Record Notification_Class Event_Enable Acked_Transitions Event_Time_Stamps (a)Properties written for Present_Value and Reliability only if Out_of_Service is TRUE. BAS-SVP05E-E4 • BCI-C Integration Guide 19 BACnet Data Points and Configuration Property Definitions BACnet Protocol Data Link Layer Options Supported Option Data Link Layer Description ANSI/ATA 878.1, 2.5 Mb ARCNET (Clause 8) ANSI/ATA 878.1, RS-485 ARCNET (Clause 8), Baud Rate(s) BACnet IP, (Annex J) BACnet IP, (Annex J), Foreign Device ISO 8802-3, Ethernet (Clause 7)(10Base2, 10Base5, 10BaseT, Fiber) LonTalk, (Clause 11), Medium MS/TP Master (Clause 9), Baud Rate(s): 9600, 19200, 38400, 76800, and 115200 @1.5% Nominal Baud Rate 9 MS/TP Slave (Clause 9), Baud Rate(s) Other Point-to-Point, EIA 232 (Clause 10), Baud Rate(s): 9600, 19200, 38400 Point-to-Point, Modem (Clause 10), Baud Rate(s): 9600, 19200, 38400 Device Address Binding Device Address Binding Supported? Static Device Binding Supported 9 Networking Options Networking Descriptions Supported Option Annex H, BACnet Tunneling BACnet/IP Broadcast Management Device (BBMD) Does the BBMD Support Registrations by Foreign Devices? Router Character Sets Indicates support for multiple characters sets, but does not imply that all character sets are supported simultaneously. Maximum supported string length is 64 bytes (any character set). Character Set Descriptions ANSI X3.4 Supported 9 IBM/Microsoft DBCS ISO 10646 (UCS-4) ISO 10646 (UCS2) 9 ISO 8859-1 9 JIS C 6226 20 BAS-SVP05E-E4 • BCI-C Integration Guide Object and Diagnostic Data Points and Corresponding Chiller Models For quick reference, the following tables are listed and sorted two different ways. Tables 3 through 8 are listed by input/output type and sorted by object identifier. These tables provide the user with the units type for each object type. Table 9, p. 27 is sorted by object name and provides a complete list of object names, types, values/ranges, and descriptions. Not all points are available to the user. The available data points are defined during self-configuration and are dependent on the type of equipment. Listed at the bottom of tables 3 through 8 are specific footnotes that correspond to either specific chiller models or object states that are identified by a larger dot or boldface text. Note: The last four columns in each table identifies which chiller model corresponds with each object name. Table 3. Analog Output Object Identifier Object Name Description Dimensionality Valid Range Relinq Default RTWD RTUD RTHD RTAC CGAM/ CXAM CGWN /CCUN Analog Output 1 Chilled Water Setpoint Desired leaving water temperature if chiller is in cooling mode. Temperature 0°F to 75°F (-17.8°C to 23.8°C) 44°F (6.7°C) • • • • • • Analog Output 2 Current Limit Setpoint Sets the maximum capacity that the chiller can use. Percent 0% to 120% 100% • • • • Analog Output 3 Demand Limit Setpoint Sets the maximum capacity that the chiller can use. Percent 0% to 120% 100% • • Analog Output 4 Hot Water Setpoint Desired leaving water temperature if chiller is in heating mode. Temperature 80°F to 140°F (26.7°C to 60°C) • • Analog Output 5 Base Loading Setpoint Capacity level to which the chiller should control when base loading is active. Percent 0% to 100% 120°F (48.9°C) • (a) • (a) • (a) • (b) • 50% (a) Leaving condenser water temperature control. (b) Hot water control with heat pumps in heating mode. Table 4. Analog Input Object Identifier Object Name Description Dimensionality Analog Input, 1 Active Cool/Heat Setpoint Temperature Active chiller water or hot water setpoint. Temperature • • • • Analog Input, 2 Active Current Limit Setpoint Active capacity current limit setpoint. Percent • • • • Analog Input, 3 Active Demand Limit Setpoint Active demand limit setpoint. Percent Analog Input 4 Active Base Loading Setpoint Value of base loading setpoint currently being used by the chiller. Percent Analog Input, 5 Actual Running Capacity Level of capacity that the chiller is currently running at. Percent Analog Input, 6 Evaporator Refrigerant PressureCkt1 Circuit 1 evaporator refrigerant pressure. Pressure Analog Input, 7 Suction Pressure- Ckt 1 Circuit 1 suction pressure. Pressure Analog Input, 8 Suction Pressure- Ckt 1 Circuit 1 suction pressure. Pressure Analog Input, 9 Evaporator Refrigerant PressureCkt 2 Circuit 2 evaporator refrigerant pressure. Pressure Analog Input, 10 Suction Pressure- Ckt 2 Circuit 2 suction pressure. Pressure BAS-SVP05E-E4 • BCI-C Integration Guide RTWD RTUD RTHD RTAC CGAM/ CXAM CGWN /CCUN • • • • • • • • • • • • • • • • • • • • • 21 Object and Diagnostic Data Points and Corresponding Chiller Models Table 4. Analog Input (continued) Object Identifier Object Name Analog Input, 11 Suction Pressure- Ckt 2 Analog Input, 12 Evaporator Saturated Refrigerant Temperature- Ckt 1 Circuit 2 evaporator refrigerant temperature. Temperature Analog Input, 13 Suction Saturated Refrigerant Temperature- Ckt 1 Circuit 1 suction refrigerant temperature. Temperature Analog Input, 14 Evaporator Saturated Refrigerant Temperature- Ckt 2 Circuit 2 evaporator refrigerant temperature. Temperature Analog Input, 15 Suction Saturated Refrigerant Temperature- Ckt 2 Circuit 2 suction refrigerant temperature. Temperature Analog Input, 16 Condenser Refrigerant PressureCkt 1 Circuit 1 condenser refrigerant pressure. Pressure Description Circuit 2 suction pressure. Dimensionality RTWD RTUD RTHD RTAC Pressure • • • • • • • • Discharge Pressure- Ckt 1 Circuit 1 discharge pressure. Pressure Analog Input, 18 Condenser Refrigerant PressureCkt 2 Circuit 2 condenser refrigerant pressure. Pressure Analog Input, 19 Discharge Pressure- Ckt 2 Circuit 2 discharge pressure. Pressure Analog Input, 20 Condenser Saturated Refrigerant Temperature- Ckt 1 Circuit 1 condenser refrigerant temperature. Temperature Analog Input, 21 Discharge Saturated Refrigerant Temperature- Ckt 1 Circuit 1 discharge refrigerant temperature. Temperature Analog Input, 22 Condenser Saturated Refrigerant Temperature- Ckt 2 Circuit 2 condenser refrigerant temperature. Temperature Analog Input, 23 Discharge Saturated Refrigerant Temperature- Ckt 2 Circuit 2 discharge refrigerant temperature. Temperature Analog Input, 24 Unit Power Consumption The power being consumed by the chiller. Power Analog Input, 25 Local Atmospheric Pressure Local atmospheric pressure. Pressure • • • Analog Input, 26 Starts- Compressor 1A Number of starts for compressor 1A. • • • Analog Input, 27 Starts- Compressor 1B Number of starts for compressor 1B. • Analog Input, 28 Starts- Compressor 2A Number of starts for compressor 2A. Analog Input, 29 Starts- Compressor 2B Number of starts for compressor 2B. Analog Input, 30 Starts- Compressor 1C Analog Input, 31 Analog Input, 32 • CGWN /CCUN • • • • • • • • • • Analog Input, 17 • CGAM/ CXAM • • • • • • • • • • • • • • • • • • • • • • • • • • • • Number of starts for compressor 1C. • • Starts- Compressor 2A Number of starts for compressor 2A. • • Starts- Compressor 2B Number of starts for compressor 2B. • • Analog Input, 33 Starts- Compressor 2C Number of starts for compressor 2C. • • Analog Input, 34 Run Time- Compressor 1A Total run time of compressor 1A. Time • • • • • Analog Input, 35 Run Time- Compressor 1B Total run time of compressor 1B. Time • • • • • Analog Input, 36 Run Time- Compressor 2A Total run time of compressor 2A. Time • • • Analog Input, 37 Run Time- Compressor 2B Total run time of compressor 2B. Time • • • Analog Input, 38 Run Time- Compressor 1C Total run time of compressor 1C. Time • • Analog Input, 39 Run Time- Compressor 2A Total run time of compressor 2A. Time • • Analog Input, 40 Run Time- Compressor 2B Total run time of compressor 2B. Time • • Run Time- Compressor 2C Total run time of compressor 2C. Time • • Analog Input, 41 22 • • • • • (a) • (a) • BAS-SVP05E-E4 • BCI-C Integration Guide Object and Diagnostic Data Points and Corresponding Chiller Models Table 4. Analog Input (continued) Object Identifier Object Name Description CGAM/ CXAM CGWN /CCUN Analog Input, 42 Airflow Percentage- Circuit 1 Approximate airflow percentage of circuit 1. Percent • • • • Analog Input, 43 Airflow Percentage- Circuit 2 Approximate airflow percentage of circuit 2. Percent • Analog Input, 44 Evaporator Entering Water Temp Temperature of the water entering the evaporator. • • • Temperature • • • • • • Analog Input, 45 Evaporator Leaving Water Temp Temperature of the water leaving the evaporator. Temperature • • • • • • Analog Input, 46 Condenser Entering Water Temp Temperature of the water entering the condenser. Temperature • • • • Analog Input, 47 Condenser Leaving Water Temp Temperature of the water leaving the condenser. Temperature Analog Input, 48 High Side Oil PressureCompressor 1A • • • • Pressure of the oil at the high side of compressor 1A. Pressure • • • Analog Input, 49 High Side Oil PressureCompressor 1B Pressure of the oil at the high side of compressor 1B. Pressure • • • Analog Input, 50 High Side Oil PressureCompressor 2A Pressure of the oil at the high side of compressor 2A. Pressure • • • Analog Input, 51 High Side Oil PressureCompressor 2B Pressure of the oil at the high side of compressor 2B. Pressure • • • Analog Input, 52 Oil Temp- Compressor 1A Temperature of the oil in compressor 1A. Temperature • Analog Input, 52 Oil Temp- Compressor 1B Temperature of the oil in compressor 1B. Temperature • Analog Input, 54 Oil Temp- Compressor 2A Temperature of the oil in compressor 2A. Temperature • Analog Input, 55 Oil Temp- Compressor 2B Temperature of the oil in compressor 2B. Temperature • Analog Input, 56 Refrigerant Disch Temp- Ckt 1 Temperature of the refrigerant being discharged from Ckt 1. Temperature Analog Input, 57 Outdoor Air Temperature Outdoor air temperature. Temperature • • Analog Input, 58 Condenser Control Output Percentage of condenser water flow being requested by the chiller. Percent • • • Analog Input, 59 Phase AB Voltage- Compressor 1A Phase AB voltage, compressor 1A. Voltage • • • • Analog Input, 60 Phase BC Voltage- Compressor 1A Phase BC voltage, compressor 1A. Voltage • • • • Analog Input, 61 Phase CA Voltage- Compressor 1A Phase CA voltage, compressor 1A. Voltage • • • • Analo5 Input, 62 Phase AB voltage, Phase AB Voltage- Compressor 1B compressor 1B. Voltage • • • Analog Input, 63 Phase BC Voltage- Compressor 1B Phase BC voltage, compressor 1B. Voltage • • • Analog Input, 64 Phase CA Voltage- Compressor 1B Phase CA voltage, compressor 1B. Voltage • • • Analog Input, 65 Phase AB Voltage- Compressor 2A Phase AB voltage, compressor 2A. Voltage • • • Analog Input, 66 Phase BC Voltage- Compressor 2A Phase BC voltage, compressor 2A. Voltage • • • Analog Input, 67 Phase CA Voltage- Compressor 2A Phase CA voltage, compressor 2A. Voltage • • • Analog Input, 68 Phase AB Voltage- Compressor 2B Phase AB voltage, compressor 2B. Voltage • • • Analog Input, 69 Phase BC Voltage- Compressor 2B Phase BC voltage, compressor 2B. Voltage • • • Analog Input, 70 Phase CA Voltage- Compressor 2B Phase CA voltage, compressor 2B Voltage • • • Analog Input, 71 Line 1 Current (in Amps)Compressor 1A Line 1 Current (in Amps)Compressor 1A Current • • BAS-SVP05E-E4 • BCI-C Integration Guide Dimensionality RTWD RTUD RTHD RTAC • • • • • • • 23 Object and Diagnostic Data Points and Corresponding Chiller Models Table 4. Analog Input (continued) Object Identifier Dimensionality RTWD CGAM/ CXAM CGWN /CCUN • • • • • • • • • • • • • • • • • Object Name Description RTUD RTHD RTAC Analog Input, 72 Line 2 Current (in Amps)Compressor 1A Line 2 Current (in Amps)Compressor 1A Current • • • • Analog Input, 73 Line 3 Current (in Amps)Compressor 1A Line 3 Current (in Amps)Compressor 1A Current • • • • Analog Input, 74 Line 1 Current (in Amps)Compressor 1B Line 1 Current (in Amps)Compressor 1B Current • • • Analog Input, 75 Line 2 Current (in Amps)Compressor 1B Line 2 Current (in Amps)Compressor 1B Current • • • Analog Input, 76 Line 3 Current (in Amps)Compressor 1B Line 3 Current (in Amps)Compressor 1B Current • • • Analog Input, 77 Line 1 Current (in Amps)Compressor 2A Line 1 Current (in Amps)Compressor 2A Current • • • Analog Input, 78 Line 2 Current (in Amps)Compressor 2A Line 2 Current (in Amps)Compressor 2A Current • • • Analog Input, 79 Line 3 Current (in Amps)Compressor 2A Line 3 Current (in Amps)Compressor 2A Current • • • Analog Input, 80 Line 1 Current (in Amps)Compressor 2B Line 1 Current (in Amps)Compressor 2B Current • • • Analog Input, 81 Line 2 Current (in Amps)Compressor 2B Line 2 Current (in Amps)Compressor 2B Current • • • Analog Input, 82 Line 3 Current (in Amps)Compressor 2B Line 3 Current (in Amps)Compressor 2B Current • • • Analog Input, 83 Line 1 Current (%RLA)Compressor 1A Line 1 Current (%RLA)Compressor 1A Percent • • • • Analog Input, 84 Line 2 Current (%RLA)Compressor 1A Line 2 Current (%RLA)Compressor 1A Percent • • • • Analog Input, 85 Line 3 Current (%RLA)Compressor 1A Line 3 Current (%RLA)Compressor 1A Percent • • • • Analog Input, 86 Line 1 Current (%RLA)Compressor 1B Line 1 Current (%RLA)Compressor 1B Percent • • • Analog Input, 87 Line 2 Current (%RLA)Compressor 1B Line 2 Current (%RLA)Compressor 1B Percent • • • Analog Input, 88 Line 3 Current (%RLA)Compressor 1B Line 3 Current (%RLA)Compressor 1B Percent • • • Analog Input, 89 Line 1 Current (%RLA)Compressor 2A Line 1 Current (%RLA)Compressor 2A Percent • • • Analog Input, 90 Line 2 Current (%RLA)Compressor 2A Line 2 Current (%RLA)Compressor 2A Percent • • • Analog Input, 91 Line 3 Current (%RLA)Compressor 2A Line 3 Current (%RLA)Compressor 2A Percent • • • Analog Input, 92 Line 1 Current (%RLA)Compressor 2B Line 1 Current (%RLA)Compressor 2B Percent • • • Analog Input, 93 Line 2 Current (%RLA)Compressor 2B Line 2 Current (%RLA)Compressor 2B Percent • • • Analog Input, 94 Line 3 Current (%RLA)Compressor 2B Line 3 Current (%RLA)Compressor 2B Percent • • • Analog Input, 95 Number of Circuits Number of Circuits None • • • Analog Input, 96 Number of Compressors, Ckt 1 Number of Compressors, Ckt 1 None • • Analog Input, 97 Number of Compressors, Ckt 2 Number of Compressors, Ckt 2 None • Analog Input, 98 Chiller Design Capacity Design Capacity of the Chiller None • (a) Power meter. 24 BAS-SVP05E-E4 • BCI-C Integration Guide Object and Diagnostic Data Points and Corresponding Chiller Models Table 5. Multistate Output Object Identifier Object Name Description Relinq Default Multi-State Output, 1 Chiller Mode Command Mode of operation of the chiller. 1 = Cool Object States 1 = HVAC _Cool 2 = HVAC_Heat 3 = HVAC_Ice (a) 4 = Not Used RTWD RTUD RTHD RTAC CGAM/ CXAM CGWN /CCUN • • • • • • RTWD RTUD RTHD RTAC CGAM/ CXAM CGWN /CCUN (a) Chiller should be selected for ice making. Table 6. BCI-C Object Identifier Multistate Input Object Name Description Object States Multi-State Input, 1 Running Mode Indicates the primary running mode of the chiller. 1 2 3 4 5 Multi-State Input, 2 Operating Mode Indicates the primary operating mode of the chiller. Multi-State Input, 3 MP Communication Status Multi-State Input, 4 Refrigerant Type = = = = = Chiller Chiller Chiller Chiller Chiller Off in Start Mode in Run Mode in Pre-shutdown Mode in Service Mode • • • • • • 1 = HVAC_Cool 2 = HVAC_Heat 3 = HVAC_Ice (a) 4 = Not Used • • • • • • Do Not Use This Point Do Not Use This Point • • • • • • Refrigerant type. 1 2 3 4 5 6 7 • • • • • • • • • • • • = = = = = = = R-11 R-12 R-22 R-123 R-134A R407C R-410A Multi-State Input, 5 Model Information Indicates the model type of the chiller. 1 = RTA 2 = CVH 3 = CVG 4 = CVR 5 = CDH 6 = RTH 7 = CGW 8 = CGA 9 = CCA 10 = RTW 11 = RTX 12 = RTU 13 = CCU 14 = CXA 15 = CGC 16 = RAU Multi-State Input, 6 Cooling Type Cooling type of the condenser. 1 = Water Cooled 2 = Air Cooled • • • • • • Location where chiller was manufactured. 1 = Field Applied 2 = La Crosse 3 = Pueblo 4 = Charmes 5 = Rushville 6 = Macon 7 = Waco 8 = Lexington 9 = Forsyth 10 = Clarksville 11 = Ft. Smith 12 = Penang 13 = Colchester 14 = Curitiba 15 = Taicang 16 = Taiwan 17 = Epinal 18 = Golbey • • • • • • Multi-State Input, 7 Manufacturing Location (a) Chiller should be selected for ice making. BAS-SVP05E-E4 • BCI-C Integration Guide 25 Object and Diagnostic Data Points and Corresponding Chiller Models Table 7. Binary Output Object Identifier Object Name Description Binary Output, 1 Chiller Auto Stop Command Binary Output, 2 Relinq Default Object States RTWD Allows the chiller to run if True conditions for running are met. Inactive = Stop Active = Auto • • • Remote Diagnostic Reset Command Resets remotely diagnostics that can be reset. False Inactive = No Reset Request Active = Reset Request • • • Binary Output, 3 Base Loading Auto/ On Request Requests chiller to use base loading. False Inactive = Auto Active = On Binary Output, 4 Noise Reduction Request Requests chiller to enter mode to reduce noise. False Inactive = Normal Active = Reduced Noise Table 8. RTUD RTHD CGAM/ CXAM CGWN/ CCUN • • • • • • RTAC • • • • Binary Input Object Identifier Object Name Description Object States Binary Input, 1 Run Enabled Indicates if the chiller is available to run or is currently running. Inactive = Stop Active = Auto • • • • • • Binary Input, 2 Local Setpoint Control Indicates if the chiller is being controlled by local setpoints instead of BAS setpoints. Inactive =Remote Control Active = Local Control • • • • • • Binary Input, 3 Capacity Limited Indicates if conditions may exist that prevent the chiller from reaching setpoint. Inactive = Not Limited Active = Limited • • • • • • Binary Input, 4 Chiller Running State Indicates if the chiller is running or stopped. Inactive = Off Active = On • • • • • • Binary Input, 5 Condenser Water Flow Status Condenser water flow status. Inactive = No Flow Active = Flow • • • Binary Input, 6 Maximum Capacity Indicates if all available chiller capacity is being used. Inactive = Off Active = On • • Binary Input, 7 Head Relief Request Indicates if the chiller is asking an Inactive = Off outside system to provide more heat Active = On rejection from the condenser water loop. • • Binary Input, 8 Base Loading Active Indicates if the base loading control method is currently being used. Inactive = Inactive Active = Active Binary Input, 9 Compressor 1A Running Indicates if compressor 1A is running. Inactive = Off Active = Running • • Binary Input, 10 Compressor 1B Running Indicates if compressor 1B is running. Inactive = Off Active = Running • Binary Input, 11 Compressor 2A Running Indicates if compressor 2A is running. Inactive = Off Active = Running Indicates if compressor 2B is running. Inactive = Off Active = Running Indicates if compressor 1C is running. Binary Input, 12 Compressor 2B Running Binary Input, 13 Compressor 1C Running Binary Input, 14 Compressor 2A Running Binary Input, 15 Compressor 2B Running RTWD RTUD RTHD RTAC CGAM/ CGWN CXAM /CCUN • • • • • • • • • • • • • • • • • Inactive = Off Active = Running • • Indicates if compressor 2A is running. Inactive = Off Active = Running • • Indicates if compressor 2B is running. Inactive = Off Active = Running • • • • • • • Binary Input, 16 Compressor 2C Running Indicates if compressor 2C is running. Inactive = Off Active = Running Binary Input, 17 Evaporator Water Pump Request Indicates a request from the chiller to turn on the evaporator water pump. Inactive = Off Active = On Binary Input, 18 Water Pump Request Indicates a request from the chiller to turn on the water pump. Inactive = Off Active = On Binary Input, 19 Condenser Water Pump Request Indicates a request from the chiller to turn on the condenser water pump. Inactive = Off Active = On • • Binary Input, 20 Noise Reduction Active Indicates if the chiller is in a state where noise is being reduced. Inactive = Off Active = On • • Binary Input, 21 Defrost Mode (or in Defrost) Indicates if one or more circuits are in a defrost mode. Inactive = Not in Defrost Active = Defrost Binary Input, 22 Evaporator Water Flow Status Indicates if water is flowing through the evaporator. Inactive = No Flow Active = Flow • • • • • • Binary Input, 23 Alarm Present Indicates if an alarm is active. Inactive = No Alarm Active = Alarm • • • • • • 26 • • • • • • • • • • (a) (a) BAS-SVP05E-E4 • BCI-C Integration Guide Object and Diagnostic Data Points and Corresponding Chiller Models Table 8. Binary Input (continued) Object Identifier Object Name Description Object States RTWD RTUD RTHD RTAC CGAM/ CGWN CXAM /CCUN Binary Input, 24 Shutdown Alarm Present Indicates if a shutdown alarm is active. Inactive = No Alarm Active = None • • • • • • Binary Input, 25 Last Diagnostic Indicates last diagnostic for the chiller. Inactive = Off Active = On • • • • • • (a) Available only on heat pumps. Table 9. All Object Types Sorted by Object Name (Refer to previous tables for detailed descriptions of objects) Object Identifier(a) Object Name Description Analog Input 4 Active Base Loading Setpoint Value of base loading setpoint currently being used by the chiller. Analog Input, 1 Active Cool/Heat Setpoint Temperature Active chiller water or hot water setpoint. Analog Input, 2 Active Current Limit Setpoint Active capacity current limit setpoint. Analog Input, 3 Active Demand Limit Setpoint Active demand limit setpoint. Analog Input, 5 Actual Running Capacity Level of capacity that the chiller is currently running at. Analog Input, 42 Airflow Percentage- Circuit 1 Approximate airflow percentage of circuit 1. Analog Input, 43 Airflow Percentage- Circuit 2 Approximate airflow percentage of circuit 2. Binary Input, 23 Alarm Present Indicates if an alarm is active. Binary Input, 8 Base Loading Active Indicates if the base loading control method is currently being used. Binary Output, 3 Base Loading Auto/On Request Requests chiller to use base loading. Analog Output 5 Base Loading Setpoint Capacity level to which the chiller should control when base loading is active. Binary Input, 3 Capacity Limited Indicates if conditions may exist that prevent the chiller from reaching setpoint. Analog Output 1 Chilled Water Setpoint Desired leaving water temperature if chiller is in cooling mode. Binary Output, 1 Chiller Auto Stop Command Allows the chiller to run if conditions for running are met. Binary Output, 1 Chiller Auto Stop Command Allows the chiller to run if conditions for running are met. Analog Input, 98 Chiller Design Capacity Design capacity of the chiller. Binary Input, 4 Chiller Running State Indicates if the chiller is running or stopped. Binary Input, 9 Compressor 1A Running Indicates if compressor 1A is running. Binary Input, 10 Compressor 1B Running Indicates if compressor 1B is running. Binary Input, 13 Compressor 1C Running Indicates if compressor 1C is running. Binary Input, 11 Compressor 2A Running Indicates if compressor 2A is running. Binary Input, 14 Compressor 2A Running Indicates if compressor 2A is running. Binary Input, 12 Compressor 2B Running Indicates if compressor 2B is running. Binary Input, 15 Compressor 2B Running Indicates if compressor 2B is running. Binary Input, 16 Compressor 2C Running Indicates if compressor 2C is running. Analog Input, 58 Condenser Control Output Percentage of condenser water flow being requested by the chiller. Analog Input, 46 Condenser Entering Water Temp Temperature of the water entering the condenser. Analog Input, 47 Condenser Leaving Water Temp Temperature of the water leaving the condenser. Analog Input, 16 Condenser Refrigerant Pressure- Ckt 1 Circuit 1 condenser refrigerant pressure. Circuit 2 condenser refrigerant pressure. Analog Input, 18 Condenser Refrigerant Pressure- Ckt 2 Analog Input, 20 Condenser Saturated Refrigerant Temperature- Ckt 1 Circuit 1 condenser refrigerant temperature. Analog Input, 22 Condenser Saturated Refrigerant Temperature- Ckt 2 Circuit 2 condenser refrigerant temperature. Binary Input, 5 Condenser Water Flow Status Condenser water flow status. Binary Input, 19 Condenser Water Pump Request Indicates a request from the chiller to turn on the condenser water pump. Multi-State Input, 6 Cooling Type Cooling type of the condenser. Analog Output 2 Current Limit Setpoint Sets the maximum capacity that the chiller can use. Binary Input, 21 Defrost Mode (or in Defrost) Indicates if one or more circuits are in a defrost mode. BAS-SVP05E-E4 • BCI-C Integration Guide 27 Object and Diagnostic Data Points and Corresponding Chiller Models Table 9. All Object Types Sorted by Object Name (Refer to previous tables for detailed descriptions of objects) (continued) Object Identifier(a) Object Name Analog Output 3 Demand Limit Setpoint Sets the maximum capacity that the chiller can use. Analog Input, 17 Discharge Pressure- Ckt 1 Circuit 1 discharge pressure. Analog Input, 19 Discharge Pressure- Ckt 2 Circuit 2 discharge pressure. Analog Input, 21 Discharge Saturated Refrigerant Temperature- Ckt 1 Circuit 1 discharge refrigerant temperature. Analog Input, 23 Discharge Saturated Refrigerant Temperature- Ckt 2 Circuit 2 discharge refrigerant temperature. Analog Input, 44 Evaporator Entering Water Temp Temperature of the water entering the evaporator. Analog Input, 45 Evaporator Leaving Water Temp Temperature of the water leaving the evaporator. Analog Input, 9 Evaporator Refrigerant Pressure- Ckt 2 Circuit 2 evaporator refrigerant pressure. Analog Input, 6 Evaporator Refrigerant Pressure- Ckt1 Circuit 1 evaporator refrigerant pressure. Description Analog Input, 12 Evaporator Saturated Refrigerant Temperature- Ckt 1 Circuit 2 evaporator refrigerant temperature. Analog Input, 14 Evaporator Saturated Refrigerant Temperature- Ckt 2 Circuit 2 evaporator refrigerant temperature. Binary Input, 22 Evaporator Water Flow Status Indicates if water is flowing through the evaporator. Binary Input, 17 Evaporator Water Pump Request Indicates a request from the chiller to turn on the evaporator water pump. Binary Input, 7 Head Relief Request Indicates if the chiller is asking an outside system to provide more heat Analog Input, 48 High Side Oil Pressure- Compressor 1A Pressure of the oil at the high side of compressor 1A. Analog Input, 49 High Side Oil Pressure- Compressor 1B Pressure of the oil at the high side of compressor 1B. Analog Input, 50 High Side Oil Pressure- Compressor 2A Pressure of the oil at the high side of compressor 2A. Analog Input, 51 High Side Oil Pressure- Compressor 2B Pressure of the oil at the high side of compressor 2B. Analog Output 4 Hot Water Setpoint Desired leaving water temperature if chiller is in heating mode. Binary Input, 25 Last Diagnostic Indicates the last diagnostic for the chiller. Analog Input, 83 Line 1 Current (%RLA)- Compressor 1A Line 1 Current (%RLA)- Compressor 1A Analog Input, 86 Line 1 Current (%RLA)- Compressor 1B Line 1 Current (%RLA)- Compressor 1B Analog Input, 89 Line 1 Current (%RLA)- Compressor 2A Line 1 Current (%RLA)- Compressor 2A Analog Input, 92 Line 1 Current (%RLA)- Compressor 2B Line 1 Current (%RLA)- Compressor 2B Analog Input, 71 Line 1 Current (in Amps)- Compressor 1A Line 1 Current (in Amps)- Compressor 1A Analog Input, 74 Line 1 Current (in Amps)- Compressor 1B Line 1 Current (in Amps)- Compressor 1B Analog Input, 77 Line 1 Current (in Amps)- Compressor 2A Line 1 Current (in Amps)- Compressor 2A Analog Input, 80 Line 1 Current (in Amps)- Compressor 2B Line 1 Current (in Amps)- Compressor 2B Analog Input, 84 Line 2 Current (%RLA)- Compressor 1A Line 2 Current (%RLA)- Compressor 1A Analog Input, 87 Line 2 Current (%RLA)- Compressor 1B Line 2 Current (%RLA)- Compressor 1B Analog Input, 90 Line 2 Current (%RLA)- Compressor 2A Line 2 Current (%RLA)- Compressor 2A Analog Input, 93 Line 2 Current (%RLA)- Compressor 2B Line 2 Current (%RLA)- Compressor 2B Analog Input, 72 Line 2 Current (in Amps)- Compressor 1A Line 2 Current (in Amps)- Compressor 1A Analog Input, 75 Line 2 Current (in Amps)- Compressor 1B Line 2 Current (in Amps)- Compressor 1B Analog Input, 78 Line 2 Current (in Amps)- Compressor 2A Line 2 Current (in Amps)- Compressor 2A Analog Input, 81 Line 2 Current (in Amps)- Compressor 2B Line 2 Current (in Amps)- Compressor 2B Analog Input, 85 Line 3 Current (%RLA)- Compressor 1A Line 3 Current (%RLA)- Compressor 1A Analog Input, 88 Line 3 Current (%RLA)- Compressor 1B Line 3 Current (%RLA)- Compressor 1B Analog Input, 91 Line 3 Current (%RLA)- Compressor 2A Line 3 Current (%RLA)- Compressor 2A Analog Input, 94 Line 3 Current (%RLA)- Compressor 2B Line 3 Current (%RLA)- Compressor 2B Analog Input, 73 Line 3 Current (in Amps)- Compressor 1A Line 3 Current (in Amps)- Compressor 1A Analog Input, 76 Line 3 Current (in Amps)- Compressor 1B Line 3 Current (in Amps)- Compressor 1B Analog Input, 79 Line 3 Current (in Amps)- Compressor 2A Line 3 Current (in Amps)- Compressor 2A Analog Input, 82 Line 3 Current (in Amps)- Compressor 2B Line 3 Current (in Amps)- Compressor 2B Analog Input, 25 Local Atmospheric Pressure Local atmospheric pressure. Binary Input, 2 Local Setpoint Control Indicates if the chiller is being controlled by local setpoints instead of BAS setpoints. 28 BAS-SVP05E-E4 • BCI-C Integration Guide Object and Diagnostic Data Points and Corresponding Chiller Models Table 9. All Object Types Sorted by Object Name (Refer to previous tables for detailed descriptions of objects) (continued) Object Identifier(a) Object Name Multi-State Input, 7 Manufacturing Location Location where chiller was manufactured. Binary Input, 6 Maximum Capacity Indicates if all available chiller capacity is being used. Indicates the model type of the chiller. Description Multi-State Input, 5 Model Information Multi-State Input, 3 MP Communication Status Communication status. Binary Input, 20 Noise Reduction Active Indicates if the chiller is in a state where noise is being reduced. Binary Output, 4 Noise Reduction Request Requests chiller to enter mode to reduce noise. Analog Input, 95 Number of Circuits Number of Circuits Analog Input, 96 Number of Compressors, Ckt 1 Number of Compressors, Ckt 1 Analog Input, 97 Number of Compressors, Ckt 2 Number of Compressors, Ckt 2 Analog Input, 52 Oil Temp- Compressor 1A Temperature of the oil in compressor 1A. Analog Input, 52 Oil Temp- Compressor 1B Temperature of the oil in compressor 1B. Analog Input, 54 Oil Temp- Compressor 2A Temperature of the oil in compressor 2A. Analog Input, 55 Oil Temp- Compressor 2B Temperature of the oil in compressor 2B. Multi-State Input, 2 Operating Mode Indicates the primary operating mode of the chiller. Analog Input, 57 Outdoor Air Temperature Outdoor air temperature. Analog Input, 59 Phase AB Voltage- Compressor 1A Phase AB voltage, compressor 1A. Analo5 Input, 62 Phase AB Voltage- Compressor 1B Phase AB voltage, compressor 1B. Analog Input, 65 Phase AB Voltage- Compressor 2A Phase AB voltage, compressor 2A. Analog Input, 68 Phase AB Voltage- Compressor 2B Phase AB voltage, compressor 2B. Analog Input, 60 Phase BC Voltage- Compressor 1A Phase BC voltage, compressor 1A. Analog Input, 63 Phase BC Voltage- Compressor 1B Phase BC voltage, compressor 1B. Analog Input, 66 Phase BC Voltage- Compressor 2A Phase BC voltage, compressor 2A. Phase BC voltage, compressor 2B. Analog Input, 69 Phase BC Voltage- Compressor 2B Analog Input, 61 Phase CA Voltage- Compressor 1A Phase CA voltage, compressor 1A. Analog Input, 64 Phase CA Voltage- Compressor 1B Phase CA voltage, compressor 1B. Analog Input, 67 Phase CA Voltage- Compressor 2A Phase CA voltage, compressor 2A. Analog Input, 70 Phase CA Voltage- Compressor 2B Phase CA voltage, compressor 2B Analog Input, 56 Refrigerant Disch Temp- Ckt 1 Temperature of the refrigerant being discharged from Ckt 1. Multi-State Input, 4 Refrigerant Type Refrigerant type. Binary Output, 2 Remote Diagnostic Reset Command Resets remotely diagnostics that can be reset. Binary Input, 1 Run Enabled Indicates if the chiller is available to run or is currently running. Analog Input, 34 Run Time- Compressor 1A Total run time of compressor 1A. Analog Input, 35 Run Time- Compressor 1B Total run time of compressor 1B. Analog Input, 38 Run Time- Compressor 1C Total run time of compressor 1C. Analog Input, 36 Run Time- Compressor 2A Total run time of compressor 2A. Analog Input, 39 Run Time- Compressor 2A Total run time of compressor 2A. Analog Input, 37 Run Time- Compressor 2B Total run time of compressor 2B. Analog Input, 40 Run Time- Compressor 2B Total run time of compressor 2B. Analog Input, 41 Run Time- Compressor 2C Total run time of compressor 2C. Multi-State Input, 1 Running Mode Indicates the primary running mode of the chiller. Binary Input, 24 Shutdown Alarm Present Indicates if a shutdown alarm is present. Analog Input, 26 Starts- Compressor 1A Number of starts for compressor 1A. Analog Input, 27 Starts- Compressor 1B Number of starts for compressor 1B. Analog Input, 30 Starts- Compressor 1C Number of starts for compressor 1C. Analog Input, 28 Starts- Compressor 2A Number of starts for compressor 2A. Analog Input, 31 Starts- Compressor 2A Number of starts for compressor 2A. BAS-SVP05E-E4 • BCI-C Integration Guide 29 BCI-C Alarming Table 9. All Object Types Sorted by Object Name (Refer to previous tables for detailed descriptions of objects) (continued) Object Identifier(a) Object Name Description Analog Input, 29 Starts- Compressor 2B Number of starts for compressor 2B. Analog Input, 32 Starts- Compressor 2B Number of starts for compressor 2B. Analog Input, 33 Starts- Compressor 2C Number of starts for compressor 2C. Analog Input, 7 Suction Pressure- Ckt 1 Circuit 1 suction pressure. Analog Input, 8 Suction Pressure- Ckt 1 Circuit 1 suction pressure. Analog Input, 10 Suction Pressure- Ckt 2 Circuit 2 suction pressure. Analog Input, 11 Suction Pressure- Ckt 2 Circuit 2 suction pressure. Analog Input, 13 Suction Saturated Refrigerant Temperature- Ckt 1 Circuit 1 suction refrigerant temperature. Analog Input, 15 Suction Saturated Refrigerant Temperature- Ckt 2 Circuit 2 suction refrigerant temperature. Analog Input, 24 Unit Power Consumption The power being consumed by the chiller. Binary Input, 18 Water Pump Request Indicates a request from the chiller to turn on the water pump. (a) AI=Analog Input, AO=Analog Output, AV=Analog Value, BI=Binary Input, BO=Binary Output, MI=Multistate Input, MO=Multistate Output BCI-C Alarming The BCI-C unit has three binary input points that are used for communicating alarms and one binary output point that is used to reset alarms remotely. Those inputs and output points are: • BI 23; Alarm Present– This object indicates if any alarms are active regardless of severity. A notification will be sent to any recipients of the Information Notification Class object when the point transitions from No Alarm to Alarm. • BI 24; Shutdown Alarm Present– This object indicates if any alarms that result in the shutdown of the chiller are active. A notification will be sent to any recipients of the Critical Notification Class object when the point transitions from No Alarm to Alarm. • BI 25; Last Diagnostic– The active text of this object will reflect the description of the last diagnostic to occur on the chiller. • BO 2; Remote Diagnostic Reset Command– This object is used to remotely reset diagnostics on the chiller. Immediately after commanding this point value to 1, the BCI-C will send the reset command to the chiller and set this point value back to 0 and clear the priority array. Note: Not all diagnostics are able to be reset remotely. Some will require local reset at the chiller front panel. 30 BAS-SVP05E-E4 • BCI-C Integration Guide Additional Resources Use the following documents and links as additional resources: • BACnet™ Communication Interface for Chillers (BCI-C) Field Kit Installation Guide (RF-SVN02) • Product support online: • www.bacnet.org • www.bacnetassociation.org • www.ashrae.org • Tracer TU Help online • Tracer™ BACnet™ Terminator Installation Instructions (X39641151-01) • Tracer™ TU Service Tool Getting Started Guide (TTU-SVN02) (X39641083) • Tracer™ TU Service Tool for Water-cooled CenTraVac™ Chillers with Tracer AdaptiView™ Control Programming Guide (CTV-SVP02) Note: For further assistance, contact your local Trane sales office. BAS-SVP05E-E4 • BCI-C Integration Guide 31 32 BAS-SVP05E-E4 • BCI-C Integration Guide Glossary A ASHRAE See American Society of Heating, Refrigeration, and Air-conditioning Engineers American Society of Heating, Refrigeration, and Airconditioning Engineers An international organization of 50,000 persons with chapters throughout the world. The Society is organized for the sole purpose of advancing the arts and sciences of heating, ventilation, air conditioning and refrigeration. It benefits the public with its research, standards writing, continuing education, and publications. advocates BACnet protocol for use in system-level control devices. Device A device is a standard BACnet object as defined by ASHRAE Standard 135-2004.The Tracer UC800 contains the BACnet object. Device ID The Device ID is used to uniquely identify each BACnet Device and it can be in the range of 0 to 4194302. There cannot be more than one device using the same Device ID. Each of the sample applications operate as a device and requires its own device id which defaults to zero. B I BACnet™ See Building Automation Control Network Interoperability The ability to integrate equipment from different vendors into a comprehensive automation and control system. In addition, digital communications between products designed independently, but designed to the same communication standard. BACnet Interoperability Building Blocks A block of BACnet application services that tells vendors what BACnet services must be implemented to provide specific device functionality. The BIBBs are grouped together into BACnet device profiles. BACnet Object An abstract representation of the physical point or points where data is input from or output to an I/O device. Each object may have several BACnet properties that describe the status of that object. P Protocol A set of rules (language) that governs the exchange of data over a digital communications system. Baud Rate The number of signaling elements that occur each second during electronic data transmission. At slow speeds, baud indicates the number of bits per second that are transmitted. For example, 500 baud means that 500 bits are transmitted each second (abbreviated 500 bps). At higher speeds, multiple bits may be encoded with each electrical change. For example, 4,800 baud may allow 9,600 bits to be sent each second. Data transmission rates at high speeds are generally expressed in bits per second (bps) rather than baud. For example, a 9,600 bps modem may operate at only 2,400 baud. BIBB See BACnet Interoperability Building Blocks Building Automation Control Network (BACnet and ANSI/ASHRAE Standard 135-2004) An interoperable protocol developed specifically for the building controls industry. The American National Standards Institute named it as a standard and Trane BAS-SVP05E-E4 • BCI-C Integration Guide 33 Glossary BAS-SVP05E-E4 • BCI-C Integration Guide 34 Glossary 35 BAS-SVP05E-E4 • BCI-C Integration Guide Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, Trane offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.Trane.com. Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. © 2011 Trane. All rights reserved. Produced on post-consumer recycled paper BAS-SVP05E-E4 23 May 2011 using environmentally friendly print practices Supersedes BAS-SVP05C-E4 May 2010 that reduce waste. ">
/
ডাউনলোড
শুধু একটি বন্ধুত্বপূর্ণ অনুস্মারক। আপনি এখানে সরাসরি নথিটি দেখতে পারেন। তবে সবচেয়ে গুরুত্বপূর্ণ, আমাদের এআই ইতিমধ্যে এটি পড়েছে। এটি জটিল বিষয়গুলিকে সহজ শর্তে ব্যাখ্যা করতে পারে, যেকোনো ভাষায় আপনার প্রশ্নের উত্তর দিতে পারে এবং এমনকি দীর্ঘতম বা সবচেয়ে জটিল নথিগুলিকে দ্রুত নেভিগেট করতে আপনাকে সহায়তা করতে পারে।
বিজ্ঞাপন