إعلان
إعلان
Symbol FormBuilder
User Guide
Symbol FormBuilder
User Guide
72E-86281-01
Revision A
November 2006
ii Symbol FormBuilder User Guide
© 2006 by Symbol Technologies, Inc. All rights reserved.
No part of this publication may be reproduced or used in any form, or by any electrical or mechanical means, without permission in writing from Symbol. This includes electronic or mechanical means, such as photocopying, recording, or information storage and retrieval systems. The material in this manual is subject to change without notice.
The software is provided strictly on an “as is” basis. All software, including firmware, furnished to the user is on a licensed basis. Symbol grants to the user a non-transferable and non-exclusive license to use each software or firmware program delivered hereunder (licensed program). Except as noted below, such license may not be assigned, sublicensed, or otherwise transferred by the user without prior written consent of Symbol. No right to copy a licensed program in whole or in part is granted, except as permitted under copyright law. The user shall not modify, merge, or incorporate any form or portion of a licensed program with other program material, create a derivative work from a licensed program, or use a licensed program in a network without written permission from Symbol. The user agrees to maintain Symbol’s copyright notice on the licensed programs delivered hereunder, and to include the same on any authorized copies it makes, in whole or in part. The user agrees not to decompile, disassemble, decode, or reverse engineer any licensed program delivered to the user or any portion thereof.
Symbol reserves the right to make changes to any software or product to improve reliability, function, or design.
Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein.
No license is granted, either expressly or by implication, estoppel, or otherwise under any Symbol
Technologies, Inc., intellectual property rights. An implied license only exists for equipment, circuits, and subsystems contained in Symbol products.
Symbol, Spectrum One, and Spectrum24 are registered trademarks of Symbol Technologies, Inc. Bluetooth is a registered trademark of Bluetooth SIG. Microsoft, Windows and ActiveSync are either registered trademarks or trademarks of Microsoft Corporation. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged.
Symbol Technologies, Inc.
One Symbol Plaza
Holtsville, New York 11742-1300 http://www.symbol.com
Revision History
Changes to the original manual are listed below:
Change
-01 Rev 1
Date
7/2006 BETA
-01 Rev A 11/2006 Symbol initial release.
(HPCM 940366-001, rev. F)
Description
About This Guide iii
iv Symbol FormBuilder User Guide
Table of Contents
About This Guide
Chapter 1: Getting Started
Chapter 2: Using FormBuilder
ii Symbol FormBuilder User Guide
Chapter 3: Security Features
Unsigned Icon with Potential Violation of Requirements ......................................... 3-6
Screen Summary Icon with Potential Violation of Requirements ............................ 3-7
Screen Element Icon with Potential Violation of Requirements .............................. 3-7
Appendix A: Reference Information
Table of Contents iii
Glossary
iv Symbol FormBuilder User Guide
About This Guide
Introduction
This guide should be used by individuals tasked with developing or maintaining customer-specific screens.
Symbol understands that each multi-lane merchant has specific graphic needs. To this end, we have endeavored to build a robust tool capable of giving you the power to implement multiple images and logo branding beyond the standard POS screens.
With FormBuilder, you will be able to create customized components to display on the multi-lane terminals.
These images can include buttons, text boxes, special messages, reminders, and appreciation screens.
NOTE
Screens and windows pictured in this guide are samples and can differ from actual screens.
IMPORTANT This guide includes information about FormBuilder, a Symbol OEM product from Hypercom
Corporation.
Any references in this guide to Hypercom Corporation, Hypercom logo, Hypercom file names and file paths, Hypercom software and terminals reflect hardware and software manufactured by
Hypercom Corporation for Symbol Technologies, Inc.
Using This Document
The assumption has been made that the user has a basic knowledge of Microsoft Windows-based applications and processes. It does not assume any prior experience with the screen building process, and will help assist the user in starting a new project and finalizing it for transfer to the Symbol Multi-Lane terminal.
Chapter Descriptions
Topics covered in this guide are as follows:
•
•
multi-lane terminals.
provides the information about FormBuilder tools how to navigate
FormBuilder to manipulate the various screen elements and commands at a basic level.
vi Symbol FormBuilder User Guide
•
•
provides the FormBuilder security features that allow the user to securely sign the project.
Appendix A, Reference Information
provides reference information used by the developers of the base application programs.
Notational Conventions
The following conventions are used in this document:
•
•
The term “FormBuilder” in this guide refers to software.
Italics are used to highlight the following:
-
Chapters and sections in this and related documents
-
Drop-down list and list box names
-
Check box and radio button names
-
Icons on a screen.
• Bold text is used to highlight the following:
-
Names of windows
-
Dialog box components.
•
• bullets (•) indicate:
-
Action items
-
Lists of alternatives
-
Lists of required steps that are not necessarily sequential
Sequential lists (e.g., those that describe step-by-step procedures) appear as numbered lists.
• Special icons:
NOTE
Notes contain neutral or positive information supplementing the main text. It is often information that applies only to special cases.
IMPORTANT Important statements draw attention to information crucial to using the product successfully. Pay special attention to Important statements.
CAUTION
Cautions advise that a negative result, such as a loss of data, may occur.
WARNING
!
Warnings provide information that is essential to the safety of the user, the equipment, or both. Failure to do as instructed may result in physical damage.
About This Guide vii
Related Documents
For the latest version of this and all payment solution guides go to: http://www.symbol.com/manuals .
viii Symbol FormBuilder User Guide
Service Information
For service information, warranty information, technical assistance or problems with the equipment, contact the regional Symbol Global Customer Interaction Center. Before calling, have the model number, serial number and several bar code symbols at hand.
Call the Global Customer Interaction Center from a phone near the scanning equipment so that the service person can try to troubleshoot the problem. If the equipment is found to be working properly and the problem is reading bar codes, the Support Center will request samples of the bar codes for analysis at our plant.
If the problem cannot be solved over the phone, it may be necessary to return the equipment for servicing. If that is necessary, the Global Customer Interaction Center will provide specific directions.
NOTE
Symbol Technologies is not responsible for any damages incurred during shipment if the approved shipping container is not used. Shipping the units improperly can possibly void the warranty. If the original shipping container was not kept, contact Symbol to have another sent.
If the Symbol product was purchased from a Symbol Business Partner, contact that Business Partner for service.
Global Customer Interaction Center
The addresses and telephone numbers below are provided for you convenience. However, this information can change due to telephone provider updates. For the most up-to-date contact number information, visit: www.symbol.com/contactsupport for a Customer Interaction Center in your area.
Country/Region
United States
Canada
United Kingdom
Asia/Pacific
Australia
Address
Symbol Technologies, Inc.
One Symbol Plaza
Holtsville, New York 11742-1300
Symbol Technologies Canada, Inc.
5180 Orbitor Drive
Mississauga, Ontario, Canada L4W 5L9
Symbol Technologies
Symbol Place
Winnersh Triangle, Berkshire RG41 5TP
United Kingdom
Symbol Technologies Asia, Inc.
(Singapore Branch)
230 Victoria Street #12-06/10
Bugis Junction Office Tower
Singapore 188024
Symbol Technologies Pty. Ltd.
432 St. Kilda Road
Melbourne, Victoria 3004
1-800-653-5350
Telephone
1-866-416-8545 (Inside Canada)
905-629-7226 (Outside Canada)
0800 328 2424 (Inside UK)
+44 118 945 7529 (Outside UK)
Tel: +65-6796-9600
Fax: +65-6337-6488
1-800-672-906 (Inside Australia)
+61-3-9866-6044 (Outside Australia)
About This Guide ix
Country/Region Address
Österreich/Austria Symbol Technologies Austria GmbH
Prinz-Eugen Strasse 70 / 2.Haus
1040 Vienna, Austria
01-5055794-0 (Inside Austria)
Danmark/Denmark Symbol Technologies AS
Dr. Neergaardsvej 3
2970 Hørsholm
Europe/Mid-East
Distributor
Operations
Suomi/Finland
France
Deutschland/
Germany
Italia/Italy
Latin America
Sales Support
Oy Symbol Technologies
Kaupintie 8 A 6
FIN-00440 Helsinki, Finland
Symbol Technologies France
Centre d'Affaire d'Antony
3 Rue de la Renaissance
92184 Antony Cedex, France
Symbol Technologies GmbH
Waldstrasse 66
D-63128 Dietzenbach, Germany
Symbol Technologies Italia S.R.L.
Via Cristoforo Columbo, 49
20090 Trezzano S/N Navigilo
Milano, Italy
2730 University Dr.
Coral Springs, FL 33065 USA
México/Mexico
Nederland/
Netherlands
Telephone
+43-1-5055794-0 (Outside Austria)
7020-1718 (Inside Denmark)
+45-7020-1718 (Outside Denmark)
Contact your local distributor or call +44 118
945 7360
9 5407 580 (Inside Finland)
+358 9 5407 580 (Outside Finland)
01-40-96-52-21 (Inside France)
+33-1-40-96-52-50 (Outside France)
6074-49020 (Inside Germany)
+49-6074-49020 (Outside Germany)
2-484441 (Inside Italy)
+39-02-484441 (Outside Italy)
Symbol Technologies Mexico Ltd.
Torre Picasso
Boulevard Manuel Avila Camacho No 88
Lomas de Chapultepec CP 11000
Mexico City, DF, Mexico
Symbol Technologies
Kerkplein 2, 7051 CX
Postbus 24 7050 AA
Varsseveld, Netherlands
1-800-347-0178 (Inside United States)
+1-954-255-2610 (Outside United States)
954-340-9454 (Fax)
5-520-1835 (Inside Mexico)
+52-5-520-1835 (Outside Mexico)
315-271700 (Inside Netherlands)
+31-315-271700 (Outside Netherlands)
x Symbol FormBuilder User Guide
Country/Region
Norge/Norway
South Africa
España/Spain
Sverige/Sweden
Address
Symbol’s registered and mailing address:
Symbol Technologies Norway
Hoybratenveien 35 C
N-1055 OSLO, Norway
Symbol’s repair depot and shipping address:
Symbol Technologies Norway
Enebakkveien 123
N-0680 OSLO, Norway
+47 2232 4375
Telephone
Symbol Technologies Africa Inc.
Block B2
Rutherford Estate
1 Scott Street
Waverly 2090 Johannesburg
Republic of South Africa
11-809 5311 (Inside South Africa)
+27-11-809 5311 (Outside South Africa)
Symbol Technologies S.L.
Avenida de Bruselas, 22
Edificio Sauce
Alcobendas, Madrid 28108
Spain
“Letter” address:
Symbol Technologies AB
Box 1354
S-171 26 SOLNA
Sweden
91 324 40 00 (Inside Spain)
+34 91 324 40 00 (Outside Spain)
Fax: +34.91.324.4010
Switchboard: 08 445 29 00 (domestic)
Call Center: +46 8 445 29 29 (international)
Support E-Mail:
Visit/shipping address:
Symbol Technologies AB
Solna Strandväg 78
S-171 54 SOLNA
Sweden
Chapter 1
Chapter 1
Chapter 1 Getting Started
Getting Started
Introduction
FormBuilder is a Windows-based tool used to create images for use on Symbol Multi-Lane terminals.
This guide should be used by individuals tasked with developing or maintaining customer-specific screens.
Symbol understands that each multi-lane merchant has specific graphic needs. To this end, we have endeavored to build a robust tool capable of giving you the power to implement multiple images and logo branding beyond the standard POS screens.
With FormBuilder, you are able to create customized components to display on the multi-lane terminals. These images can include buttons, text boxes, special messages, reminders, and appreciation screens.
Installing FormBuilder
The FormBuilder application is found on the FPE32 Developer’s Toolkit CD. FormBuilder can be started by double clicking the FormBuilder icon that is installed on the desktop.
Figure 1-1
FormBuilder icon
1 - 2 Symbol FormBuilder User Guide
Project Flow - Creation to Deployment
FormBuilder
Custom merchant projects and forms are created in FormBuilder.
Packinglist
The packinglist is created when the project is compiled in FormBuilder.
Download Packinglist
The packinglist is downloaded into a terminal using Symbol Terminal
Management Services (HTMS),
FPELoader, or FPE-Sim.
Multi-Lane Terminals
The completed forms are downloaded into live multi-lane terminals.
Figure 1-2
Project Flow
Chapter 2
Chapter 2
Chapter 2 Using FormBuilder
Using FormBuilder
Introduction
In this chapter, users learn the basics of FormBuilder and how to manipulate the various screen elements and commands.
Starting the Application
The Formbuilder application is found on the FPE32 Developer’s Toolkit CD. FormBuilder can be started by double clicking the FormBuilder icon that is installed on the desktop.
Figure 2-1
FormBuilder icon
By default, FormBuilder is installed under Start > Program Files > Hypercom > FormBuilder.
Demo projects are included on the FPE32 Developer’s Toolkit CD. Select the demo project for your terminal type and copy and paste the folder into the FormBuilder directory on your drive. The .vsp file can then be opened from within FormBuilder. Double click the .vsp file to open the project.
NOTE
If you are using Windows 2000, right click the demo_project folder for your terminal type. Select
Properties. Uncheck the read-only box. Click Apply and select Apply changes to this folder,
subfolders and files.
2 - 2 Symbol FormBuilder User Guide
The FormBuilder opening window appears:
Main Menu
Toolbar
Project Tree
File Window
Work Window
Compile, Project, and
Analysis Results tabs
Output Window
Figure 2-2
FormBuilder Opening Window
Navigating within the FormBuilder application is similar to navigating in any Windows
®
-based program.
Choices and commands can be found under the pull down menus in the main menu toolbar.
The FormBuilder main window is divided into several sections. Each section assists in navigating and constructing project information:
The Project File Tree Window is where a user navigates through the project.
The Work Window should be considered a canvas. It is here that the user places elements to create a screen.
The dotted area of a new screen is the blank canvas, and it simulates the terminal screen.
The Output Window displays important messages regarding the project. File paths or error messages are displayed here.
Using FormBuilder 2 - 3
Creating a New Project
To create a new project:
1.
From the FormBuilder main window, select File > New Project. The Create New Project dialog box appears.
Figure 2-3
Create New Project dialog box
2.
Select the Target Platform to identify the type of terminal the new project is designed for.
3.
Select the project path to identify where the project files will be stored.
4.
Type the Project Name, using up to 7 characters.
NOTE
Do not use any spaces in your project name.
5.
Click OK to save the information.
NOTE
FormBuilder automatically saves changes to a project when a screen is closed and when the project is closed.
2 - 4 Symbol FormBuilder User Guide
Screens
This section shows the user how to add screens and sub-screens, insert screens created for other projects, and analyze screen results.
Adding a Screen
The project will have a new screen for every step in the payment processing procedure. For example, a gift card purchase could have four screens:
1. Welcome, please swipe your card.
2. Please select your payment type.
3. Processing.
4. Approved. Thank you.
The following Step-by-Step demonstrates the initial creation of a set of screen files.
To add a screen:
1.
From the FormBuilder main window with your project open, click the Add Screen button on toolbar. The
Add Screen dialog box appears.
Figure 2-4
Add Screen dialog box
2.
Type a new screen name, then click OK, or click OK to accept the default name.
NOTE
Depending on what software (FPE, SCAT, or EFT) you are using to download your project to the terminals, certain screens must have specific names. See
Pre-Defined Screen Names on page A-11
list of the screen names that must be used for the terminals to process correctly.
Using FormBuilder 2 - 5
Importing Screens
FormBuilder allows the user to insert screens created for other projects.
To insert a screen:
1.
Open the project you are modifying.
2.
Select Project > Import > Screen from the main menu bar. The Open dialog box displays.
Figure 2-5
Open dialog box
1.
Browse to the project and screen to be inserted into the current project and click Open. A screen similar to the following displays:
Figure 2-6
Insert Screen box
1.
Enter the name of the screen and click OK. The newly imported screen is added to the bottom of the list of screens in the Project File Tree Window.
NOTE
Depending on what software (FPE, SCAT, or EFT) you are using to download your project to the terminals, certain screens must have specific names. See
Pre-Defined Screen Names on page A-11
list of the screen names that must be used for the terminals to process correctly.
2 - 6 Symbol FormBuilder User Guide
Creating Sub-Screens
Sub-screens are screens that have repetitive graphics or messages that can be used on multiple screens.
Using sub-screens can significantly shorten the project creation time and enhance the final project.
An example of a sub-screen would be a background screen that shows an on-screen logo. Rather than adding that image to every screen in the project, a sub-screen can be created and then applied to one or more screens.
Main Screen
Background
Sub-Screen
Image
Figure 2-7
Main screen with background sub-screen
NOTE
You can create more than one sub-screen for different applications. Multi-images can also be used on sub-screens.
To create and apply a sub-screen:
1.
Select the screen name that is to have a sub-screen added from the list of screens.
2.
Right click the screen name and select Sub-Screen. A dialog box similar to the following opens:
Figure 2-8
Selecting a Sub-Screen
Using FormBuilder 2 - 7
3.
Use the pull down to browse to the appropriate sub-screen and click OK. The sub-screen is now shown nested under the main screen image in the list of screens.
Figure 2-9
Main Screen Image with a Sub-Screen
Alignment Tools
At the bottom of the Work Window are tools used to align, resize, or nudge screen elements. These tools become available when the user selects a screen element. See
for the location of the alignment
tools.
Figure 2-10
Alignment Tools
Alignment Tools
2 - 8 Symbol FormBuilder User Guide
To grab more than one screen element, click the Select tool from the Toolbox, hold down the Control key
[CTRL] and click on each screen element you want to select. A dark border surrounds selected elements.
The Alignment Tools should be highlighted as shown below.
Selected
Not
Selected
Alignment Tools
Figure 2-11
Multiple Element Alignment Tools
NOTE
The Alignment Tools have a roll over menu that describes what each button does.
Toolbox
The Toolbox is a palette of options that allows the user to place elements into the Work Window. The toolbox
displays when an existing project is opened or a new project is started (
IMPORTANT Supported toolbox controls vary depending on the terminal type. For example, the Virtual Keyboard toolbox control is only available for use with touch screen terminals.
Toolbox
Figure 2-12
Toolbox
See
for a closer view of the toolbox controls.
Using FormBuilder 2 - 9
Select
Label
Check Box
Image
Virtual
Keyboard
MSR
Command
Button
Text Box
Option Button
Multi-Image
List Box
Figure 2-13
Toolbox Controls
Available toolbox controls include:
•
•
•
•
•
•
•
•
•
•
•
Select: moves components
Command Button: creates and defines a command button
Label: creates and defines a label for displaying static (non-changing) information
Text Box: creates and defines an edit field for entry of alpha numeric, amount, masked, numeric, PIN, or signature data
Check Box: creates and defines a check box
Option Button: creates and defines an option button
Image: creates and defines an image
Multi-Image: creates sequential images
Virtual Keyboard: creates a virtual keyboard for entry of alpha, alpha-numeric, and numeric characters
List Box: creates and defines a list box to scroll receipt items
MSR: configures Magnetic Stripe Reader (MSR) service properties
2 - 10 Symbol FormBuilder User Guide
Command Buttons
A command button can be used to either prompt customers to an action or to receive certain functional commands from the screens. Command buttons present the customer with choices.
In the example below, the command buttons allow the customer to choose a tender type. When a command button is pressed, return code is sent.
Graphic
Subscreen
Figure 2-14
Command buttons on Tender Type form
To create and configure a Command Button:
1.
Display a screen in the work window.
2.
Click the
Command Button
icon on the toolbox as shown in
Command buttons
Command
Button
Command
Button icon on toolbox
Figure 2-15
Command Button
Using FormBuilder 2 - 11
3.
Place the cursor over the desired start location for the button. Click and hold the left mouse key, drag the cursor to the desired end location for the button, then release the mouse key. An outline of the button is drawn as the cursor moves.
NOTE
If a screen contains more than one command button, each command button must have a different Return
Key. Command Buttons can be used to select amounts, such as 5.00, 10.00, 20.00, and Other. The button labeled Other must be a Function 10. See
.
4.
Double click the Command Button to open the properties box to configure the look and action of the button
(
Property
Editor Title
Element
Caption
Colors
Button
Image (s)
Return
Key
Size of
Element
& Font
Properties Property Values
Figure 2-16
Command Button Properties Box
5.
To add a graphic to a Command Button, set the Button Type property to Picture and add the graphic to the Up Picture or Down Picture properties.
2 - 12 Symbol FormBuilder User Guide
Labels
A label is similar to a text box. It displays static, read-only text. An example would be a label announcing that the lane is closed.
To create and configure a Label:
1.
Display a screen in the work window.
Click the Label icon on the toolbox as shown in
Label icon on toolbox
Label
Figure 2-17
Label with Text
2.
Place the cursor over the desired start location for the Label. Click and hold the left mouse key, drag the cursor to the desired end location for the Label, then release the mouse key. An outline of the Label is drawn as the cursor moves.
NOTE
You can resize and move the Label at any time using standard Windows methods, or by setting the
Width/Height dimensions and X/Y coordinates in the Label properties menu.
3.
Double click the Label to open the Label properties box as shown in
.
Figure 2-18
Label Properties Box
Using FormBuilder 2 - 13
Text Boxes
Text boxes allow customers to enter specific information during a transaction. In the example below, a text box has been designed for a 4 digit PIN (Personal Identification Number) entry.
Graphic
Subscreen
Command buttons
Global prompts
@G1 and
@G2
Text Box screen
Figure 2-19
Text Box on PIN entry type form
To create and configure a Text Box:
1.
Display a screen in the work window.
2.
Click the Text Box icon on the toolbox as shown in
.
Text Box
Text Box icon on toolbox
Figure 2-20
Text Box
3.
Place the cursor over the desired start location for the Text Box. Click and hold the left mouse key, drag the cursor to the desired end location for the Text Box, then release the mouse key. An outline of the Text Box is drawn as the cursor moves.
2 - 14 Symbol FormBuilder User Guide
4.
Double click the Text Box to open the Text Box properties box to configure the look and action of the box
(
Figure 2-21
Text Box Properties Box
Check Boxes
A Check Box is used to send a true or false selection to the application. A Check Box can be set to appear checked on the terminal screen.
To create and configure a Check Box:
1.
Display a screen in the work window.
2.
Click the Check Box icon on the toolbox as shown in
.
Check Box icon on toolbox
Figure 2-22
Check Box
Check Box
Using FormBuilder 2 - 15
3.
Place the cursor over the desired start location for the Check Box. Click and hold the left mouse key, drag the cursor to the desired end location for the Check Box, then release the mouse key. An outline of the
Check Box is drawn as the cursor moves.
NOTE
You can resize and move the Check Box at any time using standard Windows methods, or by setting the
Width/Height dimensions and X/Y coordinates in the Check Box properties menu.
4.
Double click the Check Box to open the Check Box properties box to configure the look and action of the
Figure 2-23
Check Box Properties Box
Option Buttons
An Option Button is used to send a true or false selection to the application. An Option Button can be set to appear selected on the terminal screen.
To create and configure an Option Button:
1.
Display a screen in the work window.
2.
Click the Option Button icon on the toolbox as shown in
Option Button
Option Button icon on toolbox
Figure 2-24
Option Button
2 - 16 Symbol FormBuilder User Guide
3.
Place the cursor over the desired start location for the Option Button. Click and hold the left mouse key, drag the cursor to the desired end location for the Option Button, then release the mouse key. An outline of the Option Button is drawn as the cursor moves.
NOTE
You can resize and move the Option Button at any time using standard Windows methods, or by setting the Width/Height dimensions and X/Y coordinates in the Option Button properties menu.
4.
Double click the Option Button to open the Option Button properties box to configure the look and action of the button (
).
Figure 2-25
Option Button Properties Box
Images
Multi-Lane terminals support the addition of graphical images to enhance the delivery of customized message to customers.
NOTE
FormBuilder is not a graphics editing application. Symbol suggests the use of Adobe Photoshop, Corel
Draw, Microsoft Paint or other digital image editing programs to fine tune the graphics before inserting them into FormBuilder.
The following image formats are supported in Formbuilder: GIF, JPEG, JPG, TIF, TIFF, BMP. Other formats are also supported. Please refer to the Properties box for a list.
Adding an image to the FormBuilder screen is done in two steps. First, you must add an image box to the screen. Think of this as a placeholder. Next, you must open the property box and add the graphic to the image box. The graphic will be associated with only that image box.
Adding an Image Box
To create an Image Box:
1.
Display a screen in the work window.
2.
Click the Image icon on the toolbox as shown in
.
Using FormBuilder 2 - 17
Image
Box
Image icon on toolbox
Figure 2-26
Image Box
3.
Place the cursor over the desired start location for the image. Click and hold the left mouse key, drag the cursor to the desired end location for the image, then release the mouse key. An outline of the Image Box is drawn as the cursor moves.
NOTE
You can resize and move the Image Box at any time using standard Windows methods, or by setting the
Width/Height dimensions and X/Y coordinates in the Image Box properties menu.
Adding a Graphic to the Image Box
To add a graphic to an image box:
1.
Double click the Image Box to open the Image properties box.
2.
Click on the Picture pull down and browse to the image file.
Pull down to browse to the image file.
Figure 2-27
Image Properties Box
2 - 18 Symbol FormBuilder User Guide
3.
Select the graphic to fill the Image Box and click Open.
Figure 2-28
Selecting an Image
The image displays in the Image Box within the Work Window screen (
Figure 2-29
Image Inserted into Image Box
NOTE
GIF animation files cannot be seen in the FormBuilder utility. However, the GIF files will be displayed on the device terminal.
Using FormBuilder 2 - 19
Adding Multi-Images
Multiple images can be displayed in one area of the screen. This feature can be used to show different images or to create a sequence of images that appear on the screen.
NOTE
You can place only one Multi-Image Box on each screen.
Graphic
Subscreen
Multi-image with rotation delay
Figure 2-30
Multiple Images on the Swipe form
To add a multiple images to the Multi-Image Box:
1.
Display a screen in the work window.
2.
Click the Multi-Image icon on the toolbox as shown in
.
Global prompts
Multi-Image
Box
Multi-Image icon on toolbox
Figure 2-31
Multi-Image Box
3.
Place the cursor over the desired start location for the Multi-Image Box. Click and hold the left mouse key, drag the cursor to the desired end location for the Multi-Image Box, then release the mouse key. An outline of the Multi-Image Box is drawn as the cursor moves.
NOTE
You can resize and move the Multi-Image Box at any time using standard Windows methods, or by setting the Width/Height dimensions and X/Y coordinates in the Multi-Image Box properties menu.
2 - 20 Symbol FormBuilder User Guide
4.
Double click the Multi-Image Box to open the Multi-Image Box properties box to configure the look and action of the box.
Browse for multiple images. They will display in the order selected.
Figure 2-32
Multi-Image Box properties Box
5.
In the Properties box, browse for the images you want to load into the Image Box.
NOTE
Only the first seven characters of each image name are shown in the properties box.
6.
Select the image and click Open.
Figure 2-33
Selecting an Image for the Multi-Image Box
The image displays in the Image Box on the Work Window screen.
7.
Select additional images as required for the multi-image display.
Images will rotate in numerical order (Picture 1, Picture 2, etc.) For example, if you wanted to display the rotating phrase Thank you for shopping with each word appearing as one image, you would follow this procedure:
Picture 1: Thank.jpg
Picture 2: you.jpg
Picture 3: for.jpg
Picture 4: shopping.jpg
Each picture would then display on the screen in a rotation pattern.
Using FormBuilder 2 - 21
Virtual Keyboards
The virtual keyboard feature allows for easy global programming for PIN pads, address forms, or other customer input fields. Choose either a standard keyboard layout or customize graphics for a more branded look. The virtual keyboard tool is not available for all terminal types.
Creating a Virtual Keyboard
To create a virtual keyboard:
1.
Display a screen in the work window.
2.
Using the Toolbox, select the Virtual Keyboard icon as shown in
.
Virtual
Keyboard
Virtual
Keyboard icon
Figure 2-34
Virtual Keyboard
3.
Place the cursor over the desired start location for the virtual keyboard in the Work Window. Click and hold the left mouse key, drag the cursor to the desired end location for the virtual keyboard, then release the mouse key. An outline of the virtual keyboard is drawn as the cursor moves.
4.
Double click the virtual keyboard to access the Virtual Keyboard Properties Box.
Figure 2-35
Virtual Keyboard Properties Box
2 - 22 Symbol FormBuilder User Guide
5.
FormBuilder supports a variety of alpha, alpha-numeric, and numeric keyboard formats. In the Property
Box, select which keyboard you need. You can also change the Background and Font colors in the
Property Box.
NOTE
You can resize and move the Virtual Keyboard at any time using standard Windows methods, or by setting the Width/Height dimensions and X/Y coordinates in the Multi-Image Box properties menu.
Creating a Custom Keyboard
Instead of using the standard virtual keyboard, the user may choose to create a custom keyboard.
, below, is an example of a custom keyboard. This customized graphic keyboard includes Command Buttons and a Virtual Keyboard return key.
Figure 2-36
Custom Numeric Keyboard
To create a custom keyboard:
1.
Display a screen in the work window.
2.
Using the Toolbox, create a command button.
3.
Double click the command button to open the Properties Box and note the X and Y pixel size of the button.
4.
Using an graphics editing program, create a custom graphic in the same X and Y pixel size as the command button. This should be button number 1.
NOTE
Should you want the Keyboard to synthesize the button being depressed, you will need to create two images. These will be assigned to the Up Picture and Down Picture options in the Property Box.
5.
In FormBuilder, duplicate the button as required using copy and paste commands.
NOTE
If you are creating a PIN screen, you will have to create an equal number of images to correspond to each numeric button. For example, Button 1 = Image 1, Button 2 = Image 2, and so on.
6.
Layout the numeric keyboard and then double click on Box 1 to access the Property Box.
7.
In the Property Box, you will have the following options to customize:
a.
Button Type (picture or text)
b.
c.
Caption (should be Button1 - do not change)
Up Picture (search for the graphic image you created)
Using FormBuilder 2 - 23
d.
e.
f.
Down Picture (search for the graphic image of a depressed button)
Return Key (select VirtKb)
VirtKbdChar (input the number 1 for button one, 2 for button two, etc.)
8.
Repeat these steps for the remainder of buttons.
NOTE
For buttons like Clear, Enter, Cancel, etc., choose the appropriate Return Key in the Property Box.
Pole Displays
FormBuilder allows you to configure a screen that lists items on the terminal. As each item is entered into the
ECR, the item is displayed in a Label on the terminal. Pole Display codes are used to identify the items. When building the item list on the FormBuilder screen, enter a Pole Display code on the caption line of each Label’s property menu.
NOTE
Pole Displays are signified with the symbol combination @PD# . Up to 30 pole displays can be used in
FormBuilder. The last PD# will be the total.
.
@PD1
@PD2
@PD3
@PD4
@PD5
@PD6
@PD7
Pole Display screen in FormBuilder
Pole Display screen on terminal
Figure 2-37
Pole Display
2 - 24 Symbol FormBuilder User Guide
List Boxes
A List Box is used to scroll receipt items on the terminal. As the item is entered into the ECR, the product is displayed in the list box. The user can add labels containing @PDs for Subtotal, Tax, and Total.
To create and configure a List Box:
1.
Display a FormBuilder screen in the work window.
2.
Click the List Box icon on the toolbox.
List Box
List Box icon on toolbox
Figure 2-38
List Box
3.
Place the cursor over the desired start location for the List Box. Click and hold the left mouse key, drag the cursor to the desired end location for the List Box, and then release the mouse key. An outline of the List
Box is drawn as the cursor moves.
NOTE
You can resize and move the List Box at any time using standard Windows methods, or by setting the
Width/Height dimensions and X/Y coordinates in the List Box properties menu.
Using FormBuilder 2 - 25
4.
Double click the List Box to open the properties box to configure the look and action of the box. Default settings are shown in
Figure 2-39
List Box Properties Box
.
5.
To add a Subtotal, Tax, or Total to the screen, use labels containing @PDs. In the example shown in
, a Total (a label containing @PD1) is added below the receipt items (list box).
List Box and Label on
FormBuilder screen
Figure 2-40
Pole Display and Label Containing @PD1
Terminal screen
2 - 26 Symbol FormBuilder User Guide
Global Prompts
Global Prompts are labels with text @G1–@G4 that allow users to configure text prompts that are displayed on the terminal.
shows a FormBuilder screen and a global prompt properties box.
Figure 2-41
Global Prompt
In the next example, a terminal display screen shows @G1and @G2 global prompts used on a Cashback type form.
Graphic
Subscreen
Global prompts
@G1 and
@G2
Command buttons
Figure 2-42
Global Prompts on Cashback type form
Using FormBuilder 2 - 27
MSR Control
A Magnetic Stripe Reader (MSR), also called a magstripe reader, is a hardware device that reads the information encoded in the magnetic stripe located on the back of a plastic card. The MSR Control allows configuration of the following MSR properties:
•
•
•
•
•
Tracks to read
Successful card swipe criteria that allow the user to specify what tracks must be read to decide whether a swipe was successful
Failed card swipe limit
Whether to enable a Smart Card Reader
Whether to enable a ISO 14443 A/B Card Reader
To configure MSR Control properties:
1.
Display a FormBuilder screen in the work window.
2.
Click the MSR Control icon on the toolbox.
MSR Control
MSR Control icon on toolbox
Figure 2-43
MSR Control
3.
Place the cursor over the desired start location for the MSR Control. Click and hold the left mouse key, drag the cursor to the desired end location for the MSR Control, and then release the mouse key. An outline of MSR Control is drawn as the cursor moves.
NOTE
You can resize and move the MSR Control at any time using standard Windows methods. Only one MSR
Control is allowed on each form and it will be invisible when the screen is displayed on the device.
2 - 28 Symbol FormBuilder User Guide
4.
To configure the action of the MSR Control, double click the MSR Control box. An MSR Control properties dialog box similar to the following is displayed:
Figure 2-44
MSR Control properties dialog box
Using FormBuilder 2 - 29
Project Settings
Project Settings tabs allow the user to access settings including information about packinglists and platforms, legacy compatibility, and screen protector replacement triggers.
To access project settings:
1.
From the main menu toolbar select Project > Settings ... A dialog box similar to the following displays:
Figure 2-45
General Tab
The General tab, shown above in
, provides project name, packinglist version, and platform
information.
2 - 30 Symbol FormBuilder User Guide
1.
Select the Legacy Compatibility tab, shown below in
, to set KSN format, Form Request ‘V’ responses, and DOS-standard file names.
Figure 2-46
Legacy Compatibility Tab
Using FormBuilder 2 - 31
2.
Select the Screen Protection Management tab, shown below in
, to set screen protector replacement triggers. If required, slide the selection bar to customize the settings.
Figure 2-47
Screen Protection Management Tab
2 - 32 Symbol FormBuilder User Guide
lists the options available from the Screen Protection Management tab.
Table 2-1
Screen Protection Management Options
Option
Maximum number of signatures allowed before the screen protector expires
Value
10,000 - 20,000 signature captures
Frequency (in days) in which the user will be reminded to replace the screen protector
1 - 7 days
Maximum number of days that signature capture is allowed after the screen protector expires
0 - 14 days
Maximum number of days that signature capture is allowed after the device detects that the screen protector is not present
0 - 14 days
Number of minutes in which the user will be reminded to install a screen protector
1 - 10 minutes
Example
If this value is set to 10,000, when signature capture number 10,001 is attempted, the application displays a message and will not allow further screen captures until the screen protector is replaced.
If this value is set to 1, the application will prompt the user will be reminded to replace the screen protector each day after the screen protector expires.
If this value is set to 14, on day 15, the application displays a message to replace the screen protector.
If the value is set to 0, signature capture will be disabled on the device immediately after the screen protector expires.
If this value is set to 0 (the default setting), as soon as the screen protector is not present, the signature capture is disabled on the device and will not be enabled until the screen protector is replaced.
If this value is set to 1 and the screen protector is removed, the application displays a message each minute.
IMPORTANT Once signature capture is disabled, the only way to enable signature capture is to replace the screen protector.
The following is an example of a message that may be displayed on the terminal, regarding signature captures:
Screen protector expired. Please replace! Do you wish to replace it right now?
If Yes is selected, the following message is displayed:
Please install screen protector and press OK.
If a new screen protector is installed and OK is selected, the screen displays the following message:
Is a new screen protector installed?
If the new screen protector has been installed and Yes is selected, signature captures are enabled.
Using FormBuilder 2 - 33
Virtual Screens
Virtual screens provide a means of grouping screens and the ability to define the position of a screen within that group. This grouping allows the FPE32 application to rotate screens. Based on business requirements, a screen designer is able to create one or several signature capture screen groups, e.g. one group to request purchase approval in English and another group to request purchase approval in Spanish. See
below as an example of how signature box screens are rotated using virtual screens.
Signature Screen Toggling
Signature screen toggling is rotating the location of the signature box to different locations on the screen to extend the life of the screen or screen protector.
In the following example, the first signature box is positioned at the bottom of the screen (SIGNATURE), the second signature box is positioned at the top of the screen (SIGNATURE1), and the third signature box is positioned in the middle of the screen (SIGNATURE2).
To use signature screen toggling:
1.
Open the project you are modifying.
2.
Create a new screen named SIGNATURE with the signature box at the bottom of the screen. The layout of this screen could be similar to the following screen:
Advertisement
Please sign below.
X _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Figure 2-48
SIGNATURE screen layout
2 - 34 Symbol FormBuilder User Guide
3.
Copy the SIGNATURE screen you created in the previous step, rename it SIGNATURE1, and move the signature box to a different location. In this example, the signature box is positioned toward the top of the
Please sign below.
X _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Advertisement
Figure 2-49
SIGNATURE1 screen layout
4.
Copy the SIGNATURE screen you created in the previous step, rename it SIGNATURE2, and move the signature box to a different location. In this example, the signature box is positioned in the middle of the screen with advertising split above and below the signature box:
Advertisement
Please sign below.
X _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Advertisement
Figure 2-50
SIGNATURE2 screen layout
Using FormBuilder 2 - 35
5.
Select Project > Manage Virtual Screens > Add from the main menu bar. The following dialog box displays:
Figure 2-51
Add Virtual Screen
6.
Enter
SIGNATURE
as the name of the virtual screen.
7.
Select Next. The following dialog box displays screens with at least one signature capture box assigned to it:
Figure 2-52
Add/Remove Screens dialog box
8.
One at a time, select the SIGNATURE, SIGNATURE1, and SIGNATURE2 screens from the Available
Screens list and click the Right Arrow to move the selected screens to the Selected Screens list as
. Use the Up Arrow and Down Arrow to arrange the screens in the order you need
them to transition when the virtual screen is selected, if they are not already in the correct order.
2 - 36 Symbol FormBuilder User Guide
9.
Click Finish. The SIGNATURE virtual screen with its selected screens (SIGNATURE, SIGNATURE1, and
SIGNATURE2) is added to the bottom of the Project File Tree window as shown below in the
example.
Figure 2-53
Virtual screen file in Project File Tree window
Using FormBuilder 2 - 37
Soft Keys
A Soft Key is used to create buttons with configurable text. A soft key code can be used to signify debit/credit buttons or even language selections.
NOTE
The format of soft keys is @B#. There can be up to nine soft keys per screen (@B1-9).
IMPORTANT If there is a soft key button on a screen, but no text has been provided, that button will be hidden and will not display on the terminal.
Soft Key
Figure 2-54
Soft Key Prompts
2 - 38 Symbol FormBuilder User Guide
Fonts
FormBuilder allows you to customize fonts on the terminal screen using HyperFont (.hfont). The FPE32
Developer’s Toolkit CD includes the Hyperfont application and several font files (.ttf). When using downloadable fonts, the fonts will only appear on the device. The fonts are not displayed in the FormBuilder application.Inserting a Font
NOTE
The length of the font name cannot exceed five characters.
1.
Select Project > Import > Font. A dialog box similar to the following opens:
Figure 2-55
Selecting a Font
2.
Select the desired font from the designated folder and click Open.
The font is inserted into the project and is displayed at the bottom of the file tree window.
Adding a Font
The following procedure is an example of how to use Hyperfont with a Text Box. You can also use Hyperfont with Command Buttons, Labels, Check Boxes, and Option Buttons.
1.
Import the desired font file into the project. See the Hyperfont Quick Reference Guide included on the
FPE32 Developer’s Toolkit CD for information on how to create and import a Hyperfont.
2.
Add a Text Box to the screen.
3.
Double click the text box to access the properties menu box.
Using FormBuilder 2 - 39
Figure 2-56
Properties Menu Box
4.
Under the Font option, pull down the menu and select Soft Font . . . A dialog box similar to the following is displayed:
Figure 2-57
Specifying custom fonts in FormBuilder
5.
Select a font from the pull down menu and click OK.
2 - 40 Symbol FormBuilder User Guide
Importing a File
FormBuilder allows the user to import a file. The following example shows how to import a signed .tcms file.
To import a file:
1.
Open the project you are modifying.
2.
Select Project > Import > File from the main menu bar. A dialog box similar to the following displays:
Figure 2-58
Open dialog box
3.
Navigate to the file and click Open. The file is added to the bottom of the Project File Tree window under
Additional files, as shown below in the
example.
Figure 2-59
Imported File under Additional Files
Using FormBuilder 2 - 41
Importing Contactless Firmware
FormBuilder allows the user to import contactless firmware. When a project is compiled, the packinglist contains the firmware file. After the packinglist download completes, the firmware reflash takes place.
To import contactless firmware:
1.
Open the project you are modifying.
2.
Select Project > Import > Contactless Firmware from the main menu bar. The following dialog box displays:
Figure 2-60
Select Contactless Card Reader dialog box
3.
Click Browse to navigate to the contactless card reader firmware.
4.
Select the firmware file and click Open.
5.
Click Next. The following dialog box displays reflash attempts, version number, and check sum:
Figure 2-61
Contactless Firmware dialog box
6.
Make any required changes and click Finish.
2 - 42 Symbol FormBuilder User Guide
Importing an Application
FormBuilder allows the user to import an application. When a project is compiled, the packinglist contains the application. After the packinglist download completes, the application load takes place.
To import an application:
1.
Open the project you are modifying.
2.
Select Project > Import > Application from the main menu bar. The Open dialog box displays.
Figure 2-62
Open dialog box
3.
Navigate to the application and click Open. The application is added to the bottom of the Project File Tree
window under Additional files, as shown below in the
Figure 2-63
Additional files in Project File Tree window
Using FormBuilder 2 - 43
Compiling the Project
After all the screens are finished, compile the project for download. FormBuilder creates a dl (download) folder containing the packinglist. The packinglist, containing the project screens, can be downloaded to a terminal.
NOTE
Each distinct ECR application has a specific method of activating the download and testing the application. Consult the specific ECR application documentation to determine the appropriate download method.
Output Window
Compile status message
Figure 2-64
Compile Option
To compile a project:
1.
Select Project > Compile or click the Compile Project button in the top right corner of the FormBuilder
, above. The result of the compile is shown on the Compile tab of the output window. If there are no errors, a compile succeeded status message appears in the output window.
NOTE
If an error occurs during compilation, an error message appears in the output window.
2 - 44 Symbol FormBuilder User Guide
Analyzing Screens
As a project is analyzed, each screen is searched to find elements that could potentially violate security requirements. For example, a Text Box with a MaxLength value greater than 3 that does not include a PIN
Entry property could violate security requirements and its security icon would be marked in red in the Output
Window as shown in
.
NOTE
for a review of security icons and what they represent.
PASSWORDFRM screen includes at least one sub-screen or screen element that potentially violates security requirements
TextBox1 potentially violates security requirements
Output
Window
Figure 2-65
Potential Violation of Security Requirements
The user can choose to initiate a screen analysis whenever they want or to change settings to analyze screens on startup each time FormBuilder is executed.
To analyze screens:
1.
Select Project > Analyze Screens. A dialog box similar to the following displays:
Figure 2-66
Analyzing Controls dialog box
Using FormBuilder 2 - 45
The analysis results are displayed in the Output Window under the Analysis Results tab at the bottom left corner of the main menu.
Analysis Results
Output Window
Figure 2-67
Analysis Results Window
OR
To analyze screens on startup each time FormBuilder is executed:
1.
Select Tools > Settings and click the General tab if it is not already selected. A dialog box similar to the following displays:
Figure 2-68
General Tab
2.
Select the Analyze Screens at Startup check box.
3.
Click OK.
The next time the project is opened, the analysis results are displayed in the Output Window under the
Analysis Results tab.
2 - 46 Symbol FormBuilder User Guide
Chapter 3
Chapter 3
Chapter 3 Security Features
Security Features
Introduction
In compliance with Payment Card Industry (PCI) and INTERAC security standards, FormBuilder supports screen security features. FormBuilder security features allow the user to securely sign the project. Symbol suggests that every project be signed.
Signing screens involves generating a digital signature and associating that signature with the project it signs.
NOTE
This FormBuilder version signs the project, not the screens individually. The screens are bundled and the bundle is signed.
A certificate is the public key of a key-pair, combined with information identifying the key’s owner and signed by the private key of a certificate authority. A certificate authority is an organization that creates and signs certificates. The signature of the certificate authority provides some guarantee that the public key in the certificate corresponds to the ownership information. A certificate is the online equivalent of an ID card. It can be used to sign files and to verify the origin of a signed file.
During a normal transaction, the system will verify the screen bundle’s signature before a screen is displayed to a customer. Should the signature not match, the PIN Pad application will refuse to display a screen. If a screen project is unsigned, certain limitations will be imposed on the screen display, which depend on the
Security mode (PCI or INTERAC) defined in the terminal Access Control List (ACL) file and limitations posed by corresponding certifications.
IMPORTANT This FormBuilder version supports screen signing for PD47XX platforms only.
3 - 2 Symbol FormBuilder User Guide
Signing Options
Before signing the project, you need to place a copy of the Controller Certificate Authority file and the Terminal
ACL file into the FormBuilder directory. Both of these files have a .crt (security certificate) extension.
Once you have added the Controller Certificate Authority (CA) file and the Terminal ACL file to the FormBuilder directory, verify the security settings in FormBuilder.
To verify the security settings:
1.
Open the FormBuilder project.
2.
Select Tools > Settings and click the Signing Options tab. A dialog box similar to the following displays:
Figure 3-1
Signing Options Tab
3.
Confirm that the Controller CA IP address and Valid From and Valid To dates are correct.
4.
Click OK.
Security Features 3 - 3
Signing a Project
To sign a project:
1.
Open the project.
2.
Ensure that all screens in the Project File Tree Window are closed.
WARNING
!
No screens can be opened for editing or preview at this time. Close and re-open the project to clear any open screens from the work window.
3.
Select Tools > Settings and click the General tab if it is not already selected. A dialog box similar to the following displays:
Figure 3-2
General Tab
4.
Click the Sign after Compilation check box.
IMPORTANT The unsigned icons in the Project File Tree Window change to signed icons when you click Apply in
Step 7 of this procedure, but the screens are not signed until the project is compiled in Step 8 of this procedure. The icons indicate that the signing option has been selected, but not necessarily that the screens have been signed.
5.
To view the screen analysis results in the Output Window, click the Analyze Screens at Startup check box.
6.
From this tab you can also choose whether or not to disable the splash screen that opens before
FormBuilder’s main screen. To disable the FormBuilder splash screen, click the Disable Splash Screen check box.
7.
Click Apply.
8.
Click Compile Project.
NOTE
When project screens are signed, subscreens are also signed. Project tree icons with red checkmarks indicate potential violation requirements.
3 - 4 Symbol FormBuilder User Guide
Revoking a Project Signature
To revoke a signature:
1.
From the open project, select Tools > Settings and click the General tab if it is not already selected. A dialog box similar to the following displays:
Figure 3-3
General Tab
2.
Uncheck the Sign after Compilation check box. The signed icons in the Project File Tree Window change to unsigned icons.
IMPORTANT The signed icons in the Project File Tree Window change to unsigned icons when you click Apply in
Step 3 of this procedure, but the signatures are not revoked until the project is compiled in Step 4 of this procedure. The icons indicate that the signing option has been unchecked, but not necessarily that the screens have been revoked.
3.
Click Apply.
4.
Click Compile Project.
Security Features 3 - 5
Security Icons
Security icons in the Project File Tree Window and the Output window show whether screen or subscreen elements are signed or unsigned and whether they potentially violate Visa PED certification requirements.
Signed Icon with
Potential Violation of
Requirements
Project
File Tree
Window
Signed Icon
Screen includes at least one sub-screen or screen element that potentially violates security requirements
Screen Element potentially violates security requirements
Output
Window
Figure 3-4
Security Icons in Project File Tree Window and Output Window
Signed Icon
. The screens that display this icon to their left in the Project File Tree
Window have been signed.
Figure 3-5
Signed Icon
3 - 6 Symbol FormBuilder User Guide
Unsigned Icon
. The screens that display this icon to their left in the Project File Tree
Window have not been signed.
Figure 3-6
Unsigned Icon
Signed Icon with Potential Violation of Requirements
The signed icon with potential violation of Visa PED security standards is shown in
that display this icon to their left in the Project File Tree Window have been signed but screen elements may not meet Visa PED security standards.
Figure 3-7
Signed Icon with Potential Violation of Requirements
Unsigned Icon with Potential Violation of Requirements
The unsigned icon with potential violation of Visa PED security standards is shown in
. The screens that display this icon to their left in the Project File Tree Window have not been signed and screen elements may not meet Visa PED security standards.
Figure 3-8
Unsigned Icon with Potential Violation of Requirements
Screen Summary Icon
A screen summary icon summarizes the security state of all screen elements within a given screen. If there is
no potential violation of requirements, the icon for a screen summary is shown in
elements within the screens that display this icon to their left in the Output Window meet Visa PED security standards.
Figure 3-9
Screen Summary Icon
Security Features 3 - 7
Screen Summary Icon with Potential Violation of Requirements
The screen summary icon with potential violation of Visa PED security standards is shown in
least one of the screen elements within the screens that display this icon to their left in the Output Window fail to meet Visa PED security standards.
Figure 3-10
Screen Summary Icon with Potential Violation of Requirements
Screen Element Icon
If there is no potential violation of security requirements, the icon for each screen element is shown in
. Screen elements that display this icon to their left in the Output Window meet Visa PED security
standards.
Figure 3-11
Screen Element Icon
Screen Element Icon with Potential Violation of Requirements
The screen element icon with potential violation of Visa PED security standards is shown in
elements that display this icon to their left in the Output Window may not meet Visa PED security standards.
Figure 3-12
Screen Element Icon with Potential Violation of Requirements
3 - 8 Symbol FormBuilder User Guide
A p p e n d i x A
A p p e n d i x A
Reference Information
Reference Information
Introduction
This chapter provides reference information used by the developers of the base application programs.
Information provided includes any variations on the screen output files, including variations on the use of the files.
Output File Name
The screen builder creates and uses a set of files. The packinglist is used to support the download of files to the terminal, each file that a terminal receives is named in the packinglist file.
The primary working files for any given project are a “vsp” file and one or more screen files. The vsp file contains general information about the screen project. The screen files contain information specific to the individual screens. Other files associated with the development of the screens may include graphic files that are included within the screens. These are called “img” files.
The compilation process produces an “scb” file, a packinglist file, and various “pcx” files. The “scb” file contains information the terminal application program uses to display the screens. The location of the various components and the names of the “pcx” files are included. The “pcx” files contain the screen images. If the packinglist has been signed, a “tcms” file is included. The packinglist also contains the names of the completed output files.
Packinglist
When a FormBuilder project is compiled, a packinglist is created or updated and placed in the DL (download) folder. The packinglist consists of a version number, an SCB file, an IMG and a Font file.
NOTE
Some packing lists may not have IMG files. An SCB file is typically listed.
FPE uses the packinglist information to determine which files need to be requested from the host PC.
Symbol provides a general packinglist for users. The user may choose to create a custom packinglist. Please contact your Client Services Manager for more information on a custom packinglist.
A - 2 Symbol FormBuilder User Guide
Sample Packing List
The following is a sample of what is contained in a packinglist
•
•
•
• project.tcms
0452
6KIMG.scb/98 picture.img/3925
Sample Packing List Components Definitions
Table A-1
Sample Packing List Components Definitions
Components Definition
project.tcms
project is the name of the project.
tcms extension indicates the packinglist has been signed.
0452
6KIMG.scb/98 picture.pcx/3925
0452 is the version number of the packinglist.
6KMIG.scb is the name of the scb file.
98 is the size of the scb file.
picture is the name of the pcx file.
3925 is the size of the pcx file.
Appendix A: Reference Information A - 3
Command Button
Property Descriptions
Table A-2
Command Button Property Descriptions
Property
Button Type
Description
Selects what appears on the button, Text or Picture.
Caption
Up Picture
Text that appears on the button when Button Type Text is selected.
Picture that appears on the button when Button Type Picture is selected.
Down Picture
Return Key
VirtKbdChar
Used to show the button in the pressed state.
Assigns a value from the pull-down list that is used by the terminal application when the button is in the pressed state. The value is provided to the terminal application in the Screen Definition
Language.
Command Buttons on the same screen must use different Return Keys.
When a PIN or Signature type screen has a Done or Enter command button, the Command Button
Return Key selection must be set to Done.
Creates a virtual keyboard on the screen. Virtual keyboard is supported on all platforms. It can be used to enter text, digits, and PINs. There are three types of virtual keyboards, alpha, alpha-numeric, and numeric. Fonts are selected from the list of available fonts.
X
Y
Fn Key Mapping Assigns values for function key mapping: Left - 1, Left - 2, Left - 3, Right - 1, Right - 2, Right - 3
Transparent True or False.
ForeColor
BackColor
Color of text on button when BTNType Text is selected. Pull-down list contains all available colors.
Color of button background when BTNType Text is selected. Pull-down list contains all available colors.
Font Font size in pixels of the button caption. Available font sizes are 10x18, 5x7, 6x12, 6x8, and 8x9.
Some fonts are not available on some terminals.
Soft Font: Hyperfont is required to create font files (.hfonts). Font file is added to a project by using the “Insert Font”. The font file used is not shown in FormBuilder, but is displayed on the device screen.
Number of pixels from the left side of the screen to the left edge of the button.
Number of pixels from the top of the screen, to the top edge of the button.
Width
Height
Width of button in pixels.
Height of button in pixels.
A - 4 Symbol FormBuilder User Guide
Return Key Codes
Table A-3
Command Button Return Key Codes
Command Button
Return Key Codes
Transaction Type
Backspace
Cancel
Clear
Done
Next Field
FuncKey1
FuncKey2
FuncKey3
FuncKey4
FuncKey5
FuncKey6
FuncKey7
FuncKey8
FuncKey9
FuncKey10
Credit
Debit
EBT
EBT Food Stamps
EBT Cash Benefits
Check
User 1
User 2
User 3
User 4
ScreenMenu1
ScreenMenu2
ScreenMenu3
ScreenMenu4
ScreenMenu5
ScreenMenu6
VirtualKdb
Scroll Pole Up
Scroll Pole Down
ADA Pin Entry
Q
O
P
M
N
K
L
I
J
G
H
E
F
C
D
A
B
Message Type
0X51
0X1B
0X01
0X49
0X4A
0X4B
0X4C
0X4D
0X4E
0X4F
0X50
0X41
0X42
0X43
0X44
0X45
0X46
0X47
0X48
Tender Type
Appendix A: Reference Information A - 5
Label Property Descriptions
Table A-4
Label Property Descriptions
Property
Caption
Transparent
Static text that appears on the Label.
True or False.
ForeColor
BackColor
Font
Description
Color of caption text on Label. Pull-down list contains all available colors.
Color of Label background. Pull-down list contains all available colors.
Font size in pixels of the Label caption. Available font sizes are 10x18, 5x7, 6x12, 6x8, and 8x9. Some fonts are not available on some terminals.
Soft Font: Hyperfont is required to create font files. (.hfonts). Font files are added to a project by using the “Insert Font”. The font file used are not shown in FormBuilder, but are displayed on the device screen.
X
Y
Width
Height
Number of pixels from the left side of the screen to the left edge of the Label.
Number of pixels from the top of the screen, to the top edge of the Label.
Width of Label in pixels.
Height of Label in pixels.
A - 6 Symbol FormBuilder User Guide
Text Box Property Box Descriptions
Table A-5
Text Box Property Box Descriptions
Property
MaxLength
Description
Maximum number of characters that can be displayed on the Text Box.
Range is 0 to 99.
MinLength
Field Type
Integrated Element
Minimum number of characters that can be displayed on the Text Box.
Range is 0 to 99.
Type of information entry required by the terminal user. Selections are:
PIN Entry - used only with Personal Identification Number (PIN). The application program developer determines the PIN type.
Numeric Entry - numeric only information is entered.
Alphanumeric Entry - alphanumeric information is entered.
Amount Entry - cashback amount is entered.
Signature Entry - used only with signature capture. The terminal user writes their name in the box so it can be captured for a transaction type that requires a signature. Signature Capture properties must be determined by the application developer.
Masked Entry - allows entered digits to be displayed as asterisks(‘*’) on the terminal display, such as a PIN entry. Masked entry does not encrypt the content, but sends it clear to ECR in
FormResponse.
Date - allows selection of date format and separator type.
SSN - allows user to enter a social security number.
Phone - allows user to enter a phone number.
Custom - allows user to specify a custom format for an edit field.
True indicates that the Text Box is contained directly in the compiled screen file. False indicates that the Text Box is called as an attachment to the screen file. The default is True.
X
Y
ForeColor
BackColor
Font
Color of text on the Text Box. Pull-down list contains all available colors.
Color of Text Box background. Pull-down list contains all available colors.
Font size in pixels of text on the Text Box. Available font sizes are 10x18, 5x7, 6x12, 6x8, and
8x9. Some fonts are not available on some terminals.
Soft Font: Hyperfont is required to create font files. (.hfonts). Font files are added to a project by using the “Insert Font”. The font file used are not shown in FormBuilder, but are displayed on the device screen.
Number of pixels from the left side of the screen to the left edge of the Text Box.
Number of pixels from the top of the screen, to the top edge of the Text Box.
Width
Height
Width of Text Box in pixels.
Height of Text Box in pixels.
Appendix A: Reference Information A - 7
Check Box Property Box Descriptions
Table A-6
Check Box Property Box Descriptions
Property
Caption
Checked
Text that appears on the box.
Description
True sets the box checked, or enabled. Default is False (not checked).
Transparent
ForeColor
BackColor
Font
True or False.
Color of text on box. Pull-down list contains all available colors.
Color of box background. Pull-down list contains all available colors.
Font size in pixels of the box caption. Available font sizes are 10x18, 5x7, 6x12, 6x8, and 8x9. All font sizes are not available on all devices.
Soft Font: Hyperfont is required to create font files (.hfonts). Font file is added to a project by using the
“Insert Font”. The font file used is not shown in FormBuilder, but is displayed on the device screen.
X
Y
Width
Height
Number of pixels from the left side of the screen to the left edge of the box.
Number of pixels from the top of the screen, to the top edge of the box.
Width of box in pixels.
Height of box in pixels.
Image Property Descriptions
Table A-7
Image Property Descriptions
Property
Picture
Description
Image that appears in the Picture Box. Use the browse feature to locate and select the image.
X
Y
Number of pixels from the left side of the screen to the left edge of the button.
Number of pixels from the top of the screen, to the top edge of the button.
Width
Height
Image in
Dump
Width of Image Box in pixels.
Height of Image Box in pixels.
True indicates that the Image Box is contained directly in the compiled screen file. False indicates that the
Image Box is called as an attachment to the screen file. The decision whether or not to embed the Image
Box is made by the application program developer and selected here.
Default is True.
A - 8 Symbol FormBuilder User Guide
Multi-Image Property Descriptions
Table A-8
Multi-Image Property Descriptions
Property Description
Rotation Delay Number of seconds each image appears on the screen. Default delay is 3 seconds. To stop image sequencing, set delay to 0.
Picture1-9
X
Y
Width
Height
Image that appears in the Multi-Image Box. Use the browse feature to locate and select the image.
Number of pixels from the left side of the screen to the left edge of the box.
Number of pixels from the top of the screen, to the top edge of the box.
Width of box in pixels.
Height of box in pixels.
Option Button Property Descriptions
Table A-9
Option Button Property Descriptions
Field Name
Caption 51
Length Description
The text to display (max 50 chars + 1 NULL). This field is padded with NULLs to a length of 51 characters.
Group 3
Index
Checked
Transparent
Fore Color
Back Color
Font
X
Y
1
1
3
3
1
3
Group number to which this radio button belongs
(0x01 - 0xFE, if set; otherwise 0xFF)
Index of the radio button within the group
Flag indicating if the radio button is selected or not
True or False
The foreground color for the element
The background color for the element
The main font to use for the element
Width
Height
3
3
3
X position of the element
Y position of the element
Width of the element
Height of the element
Appendix A: Reference Information A - 9
Virtual Keyboard Property Descriptions
Table A-10
Virtual Keyboard Property Descriptions
Field Name
Keyboard Type 3
Length Description
Alpha, Alpha-numeric, or Numeric.
Fore Color
Back Color
3
3
The foreground color for the element.
The background color for the element.
Font
X
Y
Width
Height
1
54
3
3
1
The main font to use for the element.
X position of the element.
Y position of the element.
Width of the element.
Height of the element.
List Box Property Descriptions
Table A-11
Virtual Keyboard Property Descriptions
Field Name
Control Id
Justify
Border
List Box identification number (1-999).
Left, Center, or Right.
Description
Display the List Box with or without a border (True or False).
The color of the border will be the same color of the List Box item text (same color as
).
Max Items
Fill
StepScrolling
StepUpButton
Maximum number of items in List Box.
This property configures the position of the last item scanned. The last item can be displayed at the bottom or at the top. (Bottom or Top).
Number of lines per step when scrolling List Box items.
On devices without a touch screen, it is the function key associated with the corresponding navigation button in StepUpButton and StepDown Button properties.
Used to associate List Box navigation buttons to the function keys used for scrolling up on
PD4700 terminals.
(Left - 1, Left - 2, Left - 3, Right - 1, Right - 2, Right - 3)
StepDownButton
Transparent
PageScrolling
Used to associate List Box navigation buttons to the function keys used for scrolling down on PD4700 terminals.
(Left - 1, Left - 2, Left - 3, Right - 1, Right - 2, Right - 3)
True or False.
Used to designate the number of pages to scroll up or down on PD87xx terminals.
A - 10 Symbol FormBuilder User Guide
Table A-11
Virtual Keyboard Property Descriptions (Continued)
Field Name
ForeColor Foreground color for the List Box.
BackColor
Font
Background color for the List Box.
Main font to use for the List Box.
X
Y
Width
Height
X position of the List Box.
Y position of the List Box.
Width of the List Box in pixels.
Height of the List Box in pixels.
Description
Appendix A: Reference Information A - 11
Pre-Defined Screen Names
The following screen names must be used depending on the software you are using to download the file to your terminals.
FPE Screen Names
Since the FPE application passes the screen name as one of its parameters, almost any screen name can be used. There are, however, a few exceptions. The following table illustrates the pre-defined screen names that must be used.
Table A-12
FPE Screen Names
Screen Name
CLOSEDFRM
Description
Will display at start up in a closed state.
BADSWIPE
FREQSHPFRM
GETTENDFRM
WAITFRM
CBYNFRM
Will display when a card read error occurs.
Customer Activated Mode (CAM) frequent shopper card form.
The tender selection screen in CAM.
Screen displays “Please Wait” in CAM.
Cash back prompt in CAM.
A - 12 Symbol FormBuilder User Guide
SCAT Screen Names
Table A-13
SCAT Screen Names
Screen Name
CBYNFRM
CBBUTTFRM
Cash back prompt.
Cash back buttons.
SWIPEFRM
AMNTFRM
PINFWCR
PINFRM
Description
MSR screen to swipe a card.
Prompts to confirm amount.
Prompts to enter a PIN with credit button.
Prompts to enter PIN with debit button.
GETTENFRM
YNFRM
NUMRFRM
ALFAFRM
1KEYFRM
LANGFRM
PURBALFRM
CLOSEDFRM
SELECTACC
SELECTEBT
SIGNATURE
TENPROMPT
WAITFRM
Prompts tender type selection.
Yes/No prompt screen selection.
Numeric entry screen.
The alpha entry screen.
The press one key screen.
The language selection screen.
The purchase/balance choice screen.
Displays the closed state when the ECR is closed.
The select account form screen.
The select EBT form screen.
The signature capture screen.
Tender type prompt screen.
The “Please Wait” screen.
EFT Screen Names
Table A-14
EFT Screen Names
PD8700
back
PD4700 Signed
bggp
EFTSELACC bggp1
EFTAMNTOK bgg2
EFTCARDER bggpc
EFTCBPROM EFTCLOSED
EFTCOMPLD EFTSLIDE
PD4700 Unsigned
bggp bggp1 bgg2 bggpc
EFTCLOSED
EFTSLIDE
PD4750 Signed
bggp bggpc
EFTCLOSED
EFTSLIDE
EFTPTYPE
EFTENTPIN
PD4750 Unsigned
bggp bggpc
EFTCLOSED
EFTSLIDE
EFTPTYPE
EFTENTPIN
Appendix A: Reference Information A - 13
Table A-14
EFT Screen Names (Continued)
PD8700
EFTENTPIN
PD4700 Signed
EFTPTYPE
PD4700 Unsigned
EFTPTYPE
EFTCLOSED
EFTOVRCB
EFTWAIT
EFTPROCS
EFTREFOK
EFTSELLAN
EFTSIGCAP
EFTSLIDE
EFTENTPIN
EFTAMNTOK
EFTPROCS
EFTCOMPLD
ETREPIN
EFTWAIT
EFTREFOK
EFTNWAMNT
EFTTRANCAN EFTSELACC
EFTPTYPE EFTCARDER
EFTDEFAULT EFTRANCAN backkb EFTSELLANG
EFTCBAMNT EFTOVRCB
EFTNWAMNT EFTCBPROM
EFTREPIN EFTCBAMNT
EFTDEFAULT bggp3
EFTENDPIN
EFTAMNTOK
EFTPROCS
EFTCOMPLD
ETREPIN
EFTWAIT
EFTREFOK
EFTNWAMNT
EFTSELACC
EFTCARDER
EFTRANCAN
EFTSELLANG
EFTOVRCB
EFTCBPROM
EFTCBAMNT
EFTDEFAULT bggp3
PD4750 Signed
EFTAMNTOK
EFTPROCS
EFTCOMPLD
EFTREPIN
EFTWAIT
EFTREFOK
EFTNWAMNT
EFTSELACC
EFTCARDER
EFTTRANCAN
EFTSELLANG
EFTSIGCAP
EFTOVRCB
EFTCBPROM
EFTCBAMNT
EFTDEFAULT
PD4750 Unsigned
EFTAMNTOK
EFTPROCS
EFTCOMPLD
EFTREPIN
EFTWAIT
EFTREFOK
EFTNWAMNT
EFTSELACC
EFTCARDER
EFTTRANCAN
EFTSELLANG
EFTSIGCAP
EFTOVRCB
EFTCBPROM
EFTCBAMNT
EFTDEFAULT
A - 14 Symbol FormBuilder User Guide
Screen Names to Avoid
The terminal uses certain screen names internally, and using them could cause a conflict. Avoid using the following names for your screens:
NOTE
If you must use one of these names, try to alter it slightly to avoid internal terminal conflicts
APPMODEFRM
APPSTRM1
APPSTRM2
CALIBRFRM
CLOSEDFRM
CONNECTECR
CONNECTECR2
CONNECTFRM dl
DOWNLOAD
DSPCONTRAST
DUKPTNEW2
DUKPTNEW3
DWNLDKEYS1
DWNLDKEYS2
ETHERNETFRM
EXCEPTLOG
EXTERNPINPD
FILEBROWSE
HWCONFIG
KEYPADFRM
MSENCNEW
MSENCNEW2
MSENCNEW3
MSENCTEST
MSRTEST
NETSETUP
PLDOWNLOAD
PPPFRM
SERIALCOMM
SERIALCOMM2
STARTUPFAIL
STARTUPFRM
SYSMSGFRM
SYSTMSR
TCPIPCOMM
TERMSETUP
ECRSETUP
DUKPTNEW
Appendix A: Reference Information A - 15
Windows Registry Entries
The following are the default and typical entries in the Windows Registry. These entries are to be used by the developers of the base application programs.
[HKEY_CURRENT_USER\Software\Hypercom\Form Builder]
[HKEY_CURRENT_USER\Software\Hypercom\Form Builder\Current]
“TerminalType”=”L4100”
[HKEY_CURRENT_USER\Software\Hypercom\Form Builder\Recent File List]
“File1”=”C:\ Program Files\Form Builder\Projects\ \hello\ \hello.vsp”
“File2”=”C:\ Program Files\Form Builder\Projects\ \SB Demo\ \SB Demo.vsp”
[HKEY_CURRENT_USER\Software\Hypercom\Form Builder\Run Time]
[HKEY_CURRENT_USER\Software\Hypercom\Form Builder\SDF]
[HKEY_CURRENT_USER\Software\Hypercom\Form Builder\Settings]
“ProjectDir”=”C:\Program Files\Form Builder\Projects”
“SCREENDUMP”=”YES”
“VersionsSCB”=”dword:0X00000000(0)”
“VersionTermSubType”=”dword:0X00000000(0)”
“VersionPackingList”=”dword:0X000000c9(201)”
[HKEY_CURRENT_USER\Software\Hypercom\Form Builder\ToolBox]
“Tool04”=”{D7053240-CE69-11CDA777-00DD01143C57}”
“Tool01”=”{4C599241-6926-101B-9992-00000B65C6F9}”
“Tool02”=”{978C9E23-D4B0-11CE-BF2D-00AA003F40D0}”
“Tool4”=”{346685E3-C383-11CF-A5A4-00AA00A45705}”
“Tool6”=”{8BD21D10-EC42-11CE-9E0D-00AA006002F3}”
[HKEY_CURRENT_USER\Software\Hypercom\POS Builder\UiMetrics]
A - 16 Symbol FormBuilder User Guide
Glossary
Glossary
Glossary
C
Compiler. The function of packaging the completed project for download to terminals.
E
Elements . - This terms applies to any object added to a screen. Also referred to as screen element(s).
F
FPE32. - Symbol’s proprietary software.
I
Images. Can be referred to as graphics.
O
Output Window. - The section of the FormBuilder application that displays necessary data about a project.
P
Packing List . On compilation, FormBuilder creates a packinglist that is then downloaded to the terminals.
Project . - General name used to refer to a group or series of screens created in FormBuilder.
Glossary - 2 Symbol POS Designer User Guide
Project File Tree. - The section of the FormBuilder application that displays each screen in a project. Double clicking on a screen name displays that screen in the Work Window.
Property Box. This is accessed by double clicking on a screen element. In the Property Box changes to the element are made.
R
Return Keys. The key code commands assigned to screen elements.
S
Screen. - This term can be used to refer to either computer or terminals screens created using FormBuilder.
T
Toolbox . This is a floating palette of options that can be moved around the FormBuilder application. The toolbox contains common elements used in building screens.
W
Work Window. - The FormBuilder program is divided into window frames. The Work Window is the section of the application where you add images, boxes, and text.
Symbol Technologies, Inc.
One Symbol Plaza
Holtsville, New York 11742-1300 http://www.symbol.com
72E-86281-01
Revision A - November 2006
تنزيل