- Home
- Do-It-Yourself tools
- Power tools
- Paint Sprayer
- Graco
- 308748C Contractor FTx-E Airless Spray Gun
- Owner's manual
advertisement
▼
Scroll to page 2
of 16
INSTRUCTIONS-PARTS LIST 308748 Rev. C This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. INSTRUCTIONS Contractor FTx-E Airless Spray Gun 248 bar (24.8 MPa, 3600 psi) MAXIMUM WORKING PRESSURE Model 239516, Series A Includes RACr DripLesst Guard, 517 size SwitchTipt, and 4-finger trigger. 05963 Model 239516 GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN ECOPYRIGHT 1997, GRACO INC. Graco Inc. is registered to I.S. EN ISO 9001 55440–1441 Table of Contents Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Installation/Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . 5 How to Use the Trigger Safety Latch . . . . . . . . . . . . . 5 How to Use the Gun . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 How to Adjust the Spray Pattern . . . . . . . . . . . . . . . . . . 6 How to Clean the Spray Tip and Clear a Spray Tip Obstruction . . . . . . . . . . . . 7 How to Clean the Filter . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Parts Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Graco Phone Number . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Graco Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Symbols Warning Symbol WARNING This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions. Caution Symbol CAUTION This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions. WARNING EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury. INSTRUCTIONS D This equipment is for professional use only. D Read all instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor. D Do not alter or modify this equipment. Use only genuine Graco parts. D Check equipment daily. Repair or replace worn or damaged parts immediately. D Do not exceed the maximum working pressure of the lowest rated system component. Refer to the Technical Data on page 15 for the maximum working pressure of this equipment. D Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Technical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings. D Do not use 1,1,1–trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents in pressurized aluminum equipment. Such use could result in a chemical reaction, with the possibility of explosion. D Do not use hoses to pull equipment. D Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 66_C (150_F) or below –40_C (–40_F). D Wear hearing protection when operating this equipment. D Do not lift pressurized equipment. D Comply with all applicable local, state, and national fire, electrical, and safety regulations. 2 308748 WARNING INJECTION HAZARD Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury. D Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate medical attention. D Do not point the gun at anyone or at any part of the body. D Do not put your hand or fingers over the spray tip. D Do not stop or deflect leaks with your hand, body, glove or rag. D Do not “blow back” fluid; this is not an air spray system. D Always have the tip guard and the trigger guard on the gun when spraying. D Check the gun diffuser operation weekly. See page 8. D Be sure the gun trigger safety operates before spraying. D Lock the gun trigger safety when you stop spraying. D Follow the Pressure Relief Procedure on page 5 if the spray tip clogs and before cleaning, checking or servicing the equipment. D Tighten all fluid connections before operating the equipment. D Check the hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. Do not repair high pressure couplings; you must replace the entire hose. D Fluid hoses must have spring guards on both ends, to help protect them from rupture caused by kinks or bends near the couplings. MOVING PARTS HAZARD Moving parts can pinch or amputate your fingers. D Keep clear of all moving parts when starting or operating the pump. D Before servicing the equipment, follow the Pressure Relief Procedure on page 5 to prevent the equipment from starting unexpectedly. RECOIL HAZARD Due to the high pressure fluid emitted, a strong recoil action may occur when you trigger this gun. If you are unprepared, your hand could be forced back toward your body or you could lose your balance and fall, resulting in serious injury. 308748 3 WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury. D If there is any static sparking or you feel an electric shock while using this equipment, stop spraying immediately. Do not use the equipment until you identify and correct the problem. D Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being sprayed. D Keep the spray area free of debris, including solvent, rags, and gasoline. D Electrically disconnect all equipment in the spray area. D Extinguish all open flames or pilot lights in the spray area. D Do not smoke in the spray area. D Do not turn on or off any light switch in the spray area while operating or if fumes are present. D Do not operate a gasoline engine in the spray area. D Ground the equipment and the object being sprayed. Refer to your pump instruction manual. TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed. D Know the specific hazards of the fluid you are using. D Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines. D Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and solvent manufacturer. 4 308748 Installation/Operation System Requirements WARNING Keep the wallet-sized warning card provided with this gun with the operator at all times. The card contains important treatment information should an injection injury occur. Additional cards are available at no charge from Graco Inc. WARNING Be sure your system has a bleed-type master air valve (pneumatic pumps only) and a pressure drain valve. These accessories help reduce the risk of serious bodily injury, including fluid injection, splashing in the eyes or on the skin, or injury from moving parts, if you are adjusting or repairing the pump or gun. 1. The bleed-type master air valve (air-powered pumps only) relieves air trapped between this valve and the pump after the air regulator is shut off. Trapped air can cause the pump to cycle unexpectedly. 2. The pressure drain valve assists in relieving fluid pressure in the displacement pump, hose and gun: triggering the gun to relieve pressure may not be sufficient. 3. Strain the fluid you are spraying if it contains particles which could clog the spray tip. Grounding To reduce the risk of static sparking, ground the sprayer and all other spray equipment used or located in the spray area. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Pressure Relief Procedure 1. Engage the gun safety latch. 2. Turn the ON/OFF switch to OFF. 3. Unplug the power supply cord. 4. Disengage the gun safety latch. Hold a metal part of the gun firmly to a grounded metal pail. Trigger the gun to relieve pressure. 5. Engage the gun safety latch. 6. Open the system pressure drain valve. Leave the pressure drain valve open until you are ready to spray again. If you suspect that the spray tip or hose is completely clogged, or that pressure has not been fully relieved after following the steps above, VERY SLOWLY loosen the tip guard retaining nut or hose end coupling to relieve pressure gradually, then loosen completely. Now clear the tip or hose obstruction. How to Use the Gun Trigger Safety 1. To engage the gun trigger safety, turn the latch counterclockwise toward the handle until the detent of the latch locks on and the pin is at a right angle with the gun body. See Fig. 1. 2. To disengage the gun trigger safety, turn the latch clockwise away from the handle to unlock the detent of the latch and turn the pin 180_ from the gun body. PIN WARNING LATCH INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally. Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you: D D D D are instructed to relieve the pressure, stop spraying, check or service any of the system equipment, or install or clean the spray tip. ENGAGED DISENGAGED 7186A Fig. 1 308748 5 Installation/Operation How to Use the Gun 1. Connect a grounded fluid hose to the gun inlet. See Fig. 2 2. With no tip installed, start the pump. Flush the pump according to the instructions supplied with it. Prime the system with the fluid. 3. Follow the Pressure Relief Procedure on page 5. Be sure the gun trigger safety is engaged. See Fig. 1. 7. If adjusting the pressure does not give a good spray pattern, follow the Pressure Relief Procedure on page 5 and then try another tip size. 8. Use a full-open, full-close triggering action. Hold the gun about 12 in. (305 mm) from and at right angles to the work surface. Don’t swing the gun in an arc. Practice to find the best length and speed of stroke. How to Adjust the Spray Pattern 4. Graco Flat Tip Style Driplesst Guard Install the tip (A) and the gasket (B) in the nut of the tip guard (C). Screw the assembly firmly onto the gun. Tighten the assembly with a wrench. See Fig. 2. NOTE: If the gasket (B) is not installed, the gun will leak. 5. Reverse-A-Clean (RAC) IV Model 239516 Install the RAC IV SwitchTip (40) and the tip guard (41). See manual 308644, supplied. See Fig. 2. 1. To adjust the spray pattern direction, follow the Pressure Relief Procedure on page 5. Loosen the tip guard retaining nut (B). Turn the tip guard/ tip groove horizontally (C) for a horizontal pattern and vertically (A) for a vertical pattern. Tighten the nut. See Fig. 3. 2. The spray tip orifice and spray angle determines the coverage and size of pattern. When more coverage is needed, use a larger spray tip rather than increasing fluid pressure. CAUTION 41 The openings in the tip guard reduce paint buildup on the tip guard while spraying. Any damage to the sharp edges of the openings causes paint to collect at that area. Never hang the gun by the tip guard. 40 05965 A KEY A Tip guard shown in position for vertical spray pattern B Retaining nut C Tip guard shown in position for horizontal spray pattern B C B C A Fig. 2 A 6. Start the pump. Adjust the fluid pressure until the spray is completely atomized. Use the lowest pressure necessary to get the desired results. Higher pressure may not improve the spray pattern and will cause premature tip wear and pump wear. 6 308748 05971 Fig. 3 Installation/Operation How to Clean the Spray Tip and Clear a Spray Tip Obstruction WARNING To reduce the risk of fluid injection or splashing in the eyes or on the skin, do not hold a hand, body or rag in front of the spray tip when cleaning or checking a clogged tip. Point the gun toward the ground or into a waste container when checking to see if the spray tip is cleared. DO NOT try to “blow back” paint; this is NOT an air spray gun. DO NOT wipe fluid buildup off the gun or spray tip until pressure is relieved. Cleaning during the day. 1. Follow Pressure Relief Procedure on page 5. 2. Clean the front of the tip frequently during the day to help reduce buildup. Also clean the tip and tip guard at the end of each work day. Use a solventsoaked brush to clean the spray tip. 2. Remove the spray tip and blow out the obstruction by applying air to the front of the spray tip. Or, let the spray tip and gun nozzle soak to dissolve the obstruction. If it won’t dissolve, jar it out by tapping the back of the spray tip against a flat surface. Gun with RAC IV Tip and Guard; Models 239516 1. Lock the gun trigger safety. Rotate the RAC IV tip handle 180_. See Fig. 4. 2. Unlock the gun trigger safety. Trigger the gun into a pail or onto the ground to remove the clog. 3. Lock the gun trigger safety. Rotate the tip handle to the spraying position. 4. If the tip is still clogged, lock the gun trigger safety, shut off the sprayer and disconnect the power source, and open the pressure drain valve to relieve pressure. Clean the spray tip as shown in manual 308644, supplied with the RAC IV. Clearing an obstruction. A If the spray tip clogs while spraying, immediately stop spraying, then: Gun with Standard Flat Tip and Guard 1. Lock the gun trigger safety, open the pressure drain valve. CAUTION Never soak the entire gun in solvent. Prolonged exposure to solvent can ruin the packings. KEY A Handle shown in spraying position. Turn handle 180_ and trigger gun to clear clog. 05966 Fig. 4 308748 7 Installation/Operation How to Check the Gun Diffuser Operation 4. Apply lithium-base grease to the threads of the gun handle (14) and reassemble the gun. Check the diffuser operation weekly. The gun diffuser/ seat (A) breaks up spray and reduces the risk of fluid injection when the tip is not installed. Perform the test below. If it fails, replace the entire Needle Kit, Part No. 218070, as instructed on page 10. Diffuser/seats are not sold separately since the gun will leak if an old needle is used with a new diffuser/seat. A 1. Follow Pressure Relief Procedure on page 5. 05967 2. Remove the tip guard and spray tip. Fig. 5 3. Start the sprayer and adjust it to the lowest pressure. 26 4. Aim the gun into a grounded metal pail while holding it firmly to the pail. Trigger the gun. If the fluid emitted is not diffused into an irregular stream, replace the entire needle kit immediately. See Fig. 5. How to Clean the Filter (See Fig. 6.) 5 Clean the filter assembly (17) daily, as follows: 1. Follow Pressure Relief Procedure on page 5. 12 2. Push up on the trigger guard (12) and swing it away from the trigger (5). 3. Unscrew the gun handle (6) from the housing (26). Remove the filter and clean it in compatible solvent. 8 308748 6 Fig. 6 05968 Installation/Operation How to Flush the Gun WARNING ÄÄ To reduce the risk of serious bodily injury, including splashing fluid in the eyes or on the skin, or static electric discharge when flushing: D Be sure the entire system, including flushing pails, are properly grounded. D Remove the tip guard and spray tip. D Maintain metal to metal contact between the gun and the flushing pail. D Use the lowest possible pressure. Always flush the pump and the gun before the fluid being sprayed can dry in it. NOTE: If it is available, the flushing procedure provided in your pump or sprayer manual should be used instead of this procedure. WARNING Do not spray paint from the gun with the gun safety latch set to the cleaning position. 7. Trigger the gun. Rotate the latch clockwise all the way up to the cleaning position as shown in Fig. 7. Release the trigger. The gun is now in continuous cleaning mode without the need to manually trigger the gun. 8. Aim the gun into the solvent pail. Start the pump at its lowest pressure. Circulate the fluid until the system is thoroughly flushed. 9. Trigger the gun and turn the latch counterclockwise to rotate the pin parallel with the gun. Release the trigger to stop flushing. 10. Follow the Pressure Relief Procedure, page 5. PIN 1. Follow Pressure Relief Procedure on page 5. LATCH 2. Remove the tip guard and spray tip. Soak and clean the parts. 3. Put the pump intake in a grounded pail of water or solvent. 4. Start the pump at its lowest pressure. 5. Trigger the gun into the original pail. When water or solvent appears, release the trigger. 6. Follow the Pressure Relief Procedure, page 5. 07186A Fig. 7 308748 9 Service 4. If the gun handle (6) was removed, hand tighten it into the fluid housing (26); it should fit easily. D 23 C 1 A 5. Adjust the needle before using the gun. Procedure below. 4 6. Be sure the trigger guard and tip guard are installed before using the gun. B Adjusting the needle (See Fig. 9) 1. Engage the gun safety latch. 05970 2. Hold the gun with the nozzle straight up. 1 Torque to 26–32 ft-lb (35–43 N.m) Fig. 8 3. Hold your finger against the trigger with light pressure. Turn the locknut (D) clockwise until you feel the trigger depress slightly. NOTE: The needle (C), diffuser/seat (A), gasket (B) and locknut (D) must be replaced together. They are included in Repair Kit 218070. 4. Turn the adjusting nut 3/4 turn counterclockwise. Disassembly (See Fig. 8 ) 1. Follow the Pressure Relief Procedure on page 5. 2. Remove the tip guard assembly. See Fig. 2. 5. Connect the fluid hose. Install the tip guard and prime the system. Trigger the gun and release it. The fluid flow should stop immediately. Engage the safety latch and try to trigger the gun. No fluid should flow. If the gun fails either test, relieve pressure, disconnect the hose and readjust the needle. 3. Squeeze the trigger while unscrewing the diffuser/ seat (A) and gasket (B). 1 4. Remove the locknut (D) and end cap (23). 5. Tap the rear of the gun with a plastic mallet to push the needle assembly out the front. D Reassembly (See Fig. 8) 1. Guide the threaded end of the needle assembly into the front of the gun. 2. Install the end cap, aligning its guides with the holes in the rear of the gun. Install the locknut (D) loosely. 3. Squeeze the trigger while installing the gasket (B) and diffuser/seat (A). Torque the diffuser seat to 26–32 ft-lb (35–43 N.m). 10 308748 2 1 2 Fig. 9 Engage trigger safety latch Arrows indicate clockwise turn 05972 Service Replace Swivel Reassembly (See Fig. 10) 1. Clean internal thread of handle (6). Disassembly 1. Follow Pressure Relief Procedure on page 5. 2. Push up on trigger guard (12) and swing trigger guard away from trigger (5). 3. Unscrew gun handle (6) from housing (26). Remove filter and clean in compatible solvent. 2. Install guard retainer (42), cushion o-ring (43) and swivel (15). 3. Apply PST pipe seal (included in Swivel Kit 238817) to external thread of swivel (15) that connects to handle (6). 4. Remove swivel (15), guard retainer (42) and cushion o-ring (43). 4. Install swivel (15) into handle (6). Torque swivel to 250 in-lb. 5. Save guard retainer and cushion o-ring. 5. Engage trigger guard (12) to retainer guard (42). 12 6 42 43 15 Fig. 10 05968 308748 11 Parts Drawing Model 239516, Series A 32 26 23 Included with 1 21 33 31 1 n40 18 22n n41 17 20 16 5 37 2 12 6 45 1 2 05962A 42 45 43 15 12 308748 1 Purchase separately 2 Included with 239045 Parts List Model 239516, Series A Ref. No. Part No. Description 1 5 6 11Y 12 15 16 17n 218070 239520 195788 187348 195495 238200 179750 218131 NEEDLE–DIFFUSER/SEAT KIT 4-FINGER TRIGGER (standard) HANDLE, round COVER, warning TRIGGER GUARD SWIVEL, gun SPRING RETAINER FLUID FILTER ASSEMBLY (standard 50 mesh) includes replaceable items 16, 18, 20, 21 18 179731 20 21 179763 179722 Ref. No. Part No. Description 1 1 1 1 1 1 1 1 31 32 33 37 39Y 40n 41n 105334 177538 179737 195419 222385 274517 237859 LOCKNUT; M4 x 0.7 thread TRIGGER STUD ACTUATOR PIN NEEDLE HOUSING WARNING CARD (not shown) SWITCHTIP SPRAY TIP, SZ 517 RAC DripLess Guard 1 1 2 1 1 1 1 See manual 308644 for other tip sizes 1 1 42 43 45 113409 104938 220251 RETAINER, guard O-RING, cushion KIT, tip guard 1 1 1 1 Qty. STRAINER ELEMENT (standard 50 mesh) 22n 23 26 179733 191244 190973 SPRING SPRING RETAINER (color coded blue) 1 (for standard 50 mesh filter) 1 1 1 1 GASKET END CAP FLUID HOUSING Qty. Y Replacement Danger and Warning labels, tags and cards are available at no cost. n Keep these spare parts on hand to reduce down time. 308748 13 Accessories FILTERS 220222 Standard DripLesst Tip Guard. Order flat tip separately. See your distributor for available sizes. 222674 Heavy Duty RACR DripLesst Tip Guard. Order SwitchTip separately. See your distributor for available sizes. 3000 psi (210 bar) Maximum Working Pressure. Adequate filtering is important for a good surface finish and to minimize tip clogging. Elements are available in various mesh sizes. Filter elements and assemblies 224455 Two, 50 mesh elements, (179731) 224456 Two, 100 mesh elements, (179732) 218131 50 mesh filter assembly; includes spring, 50 mesh element and two spring retainers FINE FINISH RAC TIPS 100 mesh filter assembly; includes spring, 100 mesh element and two spring retainers These tips provide and extremely fine finish with more consistent material thickness. See your distributor for available sizes. 218133 TOOLS TIP EXTENSIONS Nylon Brushes Use to thoroughly clean the gun’s fluid passages. 101891 101892 0.375” (9 mm) dia. 0.625” (16 mm) dia. Wrench 171147 Fits all hexes on the gun. TIP GUARDS These tip guards fit all Graco airless spray guns. Choose the one that’s right for your application. One of these tip guards is included with every Graco airless gun. 237859 14 These tip extensions extend tip from the spray gun to spray hard to reach areas. RACR DripLesst Guard. Order SwitchTip separately. See your distributor for available sizes. 308748 223390 12 inch extension 223391 18 inch extension 223392 24 inch extension HEAVY DUTY EXTENSIONS Provides extended spraying for hard to reach applications. 224413 12 inch extension 224414 18 inch extension 224415 36 inch extension 224416 72 inch extension 236406 Includes 18 in. and 36 in. heavy duty extension; RAC IV dripless tip guard; 180_ directional nozzle; and 45_swivel. Technical Data Maximum Working Pressure . . . . . . . . . . . . . . . 248 bar (24.8 MPa, 3600 psi) Fluid Orifice Size . . . . . . . . . . . . . . . 3.18 mm (0.125 in.) Wetted Parts . . . . . . . . . Stainless steel, Polyethylene, Aluminum, Polyurethane, Nylon, PTFE R Brass, Tungsten carbide, UHMW Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 482 g (17 oz.) Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4 npsm(m)swivel Maximum Material Temperature . . . . . . . 50_C (120_F) Sound Data Sound Pressure Level . . . . . . . . . . . . . . . 78 dB(A)*{ Sound Power Level . . . . . . . . . . . . . . . . . . . 87 dB(A){ * Measured at 1 meter { Measured while spraying waterbase paint – gravity 1.36 through a 517 tip at 207 bar (20.7 MPa, 3,000 psi). Per ISO 3744 Graco Phone Number TO PLACE AN ORDER, contact your Graco distributor, or call this number to identify the distributor closest to you: 1–800–690–2894 Toll Free. PTFE R 308748 15 Graco Warranty Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special extended or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance or structures, accessories, equipment or materials not supplied by Graco. This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation. Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale. GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, gas engines, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties. In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise. FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées. ADDITIONAL WARRANTY COVERAGE Graco does provide extended warranty and wear warranty for products described in the “Graco Contractor Equipment Warranty Program”. All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. Sales Offices: Minneapolis, Detroit Foreign Offices: Belgium, Korea, Hong Kong, Japan GRACO INC. 16 308748 P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 PRINTED IN U.S.A. 308748 March 1997, Revised October 1999
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project