GST200-2 Panel Overview
1
1/2-Loop Fire Panel
GST200-2/1 GST200-2
1/2 Loop Addressable Fire Alarm Control
Panel
1 loop or 2 loops,235 devices for 1 st loop,242 device for 2 nd loop
30 zones fire and fault/disable indication
PAS and Acknowledge Function
Dirty detector reporting
Walk test feature
Build in RS485 repeater output, (maximum10 repeaters)
Standard: EN54-2/EN 54-4
Mains supply: 220/230VAC 50/60Hz
Backup battery: 24VDC/22AH
Optional Language version: Portuguese & Hungary
(Keypad, Fascia, LCD text display)
2
Addressable Fire Panel
Optional Components for GST200-2
P-9901A
Micro Thermal Printer
Specification:
Power: 5v (from GST200-2 internal PSU
Communication: Ribbon cable connect to
GST200-2 main board printer port
Support all ASCII character
3
Addressable Fire Panel
Optional Components for GST200-2
LC200
Loop card (2
nd
Loop)
Specification:
Power: 24v (from GST200-2 internal PSU)
Communication: Ribbon cable connect to
GST200-2 main board XS2
Expand one more loop for GST200-2/1 panel
Loop capacity :242 points
4
Addressable Fire Panel
Optional Components for GST200-2
P-9930
GST200-2 Communication Card
Specification:
Powered by GST200-2 main board
RS232 or USB communication Interface between computer and GST200-2 panel
Communication: 20 pin Ribbon cable connect to GST200-2 main board XS2
5
Addressable Fire Panel
Optional Components for GST200-2
P-9940A
RS485 class A network card
Specification:
Powered by GST200-2 main board
Communication: 20 pin Ribbon cable connect to GST200-2 main board XS2 port
Networking interface with all GST intelligent FACP RS485 Class A network
6
Addressable Fire Panel
Optional Components for GST200-2
P-9960
Class B CAN network card
Specification:
Powered by GST200-2 main board
Communication: 20 pin Ribbon cable connect to GST200-2 main board XS2 port
Networking interface with all GST intelligent FACP CAN network
7
Addressable Fire Panel
Optional Components for GST200-2
P-9960A
Class A CAN network card
Specification:
Powered by GST200-2 main board
Communication: 20 pin Ribbon cable connect to GST200-2 main board XS2 port
Networking interface with all GST intelligent FACP CAN network
8
Panel Overview GST-200-2 Structure
Structures
9
Panel Overview GST-200-2 Fascia
Fascia
LCD Display 8x18 Control Buttons LED indicator
Buttons & 32 Zone Indication & Manual
Intervention
Panel Keypad
10
Panel Overview GST-200-2 Internal Parts Overview
Panel PSU
AC Power Filter
Terminal Board
(Loop 1 interface Board)
230V to27V AC Transformer
11
Panel Overview GST-200-2 Internal Parts Overview
Manual Intervention and
Zone Indication Board
Main Board
LED and keypad board
LCD Screen
12
Panel Overview GST-200-2 Internal Wiring Diagram
System
Diagram
RS 232 CARD
(Optional)
Serial port
USB port
XS2
XS3
H L1 H L2
+ +
D1
Network CARD
B2
A2
OTHER FACP
B1
A1
P-9940A
1.2Km bet two panels
B1
A1
B2
A2
XS1
F7.820.913
D1
+ + +
H L3 H L2 H L1
XS1
F7.820.1007
F7.820.1125
H L2
XS2
Loop 2 CARD
(GS200/2/1-Optional)
Loop 2 CARD
(GS200/2/2-Supplied)
XT2 + 2 4 V G N D
H L1 H L3
F7.820.828V1
Loop 1 Board
Terminal Board
(Supplied)
_
X4
HL5
F1
X5
X6
F2
X7
F3
X1
HL2
HL3
X2
HL4
X3
X8
EARTH
A C Input
AC Filter
L G N
+ 5 V G N D G N D + 5 V G N D + 2 4 V + 2 4 V G N D
Power Supply Unit
CHARGER
FAULT
H L1
_ BAT +
OFF
0 I
ON
FUSE
F7.820.829bV1
OFF
0 I
ON
AC 16-30V
XS13
A
B
XS13
24V+
24V-
B AT Fault
AC Fault
5V
GND
Main Control Board
SPEAKE R
E XTE NDE D P ORT
XS7
D17
XS12
SK1
D 4
D 8 D 9
LED P ORT
XS6
P RINTE R PORT
XS11
BACK
LIGHT
+
SPEAKE R
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
H L
H L
+ +
32 Manual Intervention zone and indicator board Printer
G N D + 5 V
Step-down Transformer
24V Batteries
-
12V
+ -
12V
+
13
Panel Overview GST-200-2 External Wiring Diagram
F7.820.828V1
Output to Repeater or Mimic Panel
Monitored
Terminal
Board
No connec tion
Refers to Optional
Network B oard
Loop Out (Out to First Device)
LOOP 1
Loop In (In From Last Device)
OR
4.7Kohm s
EOL
O/P
Output Device with fitted diode
4.7Kohm s
EOL
FPE
Sounder with built-in diode
FPE with fitted diode
FPE
4.7Kohm s
EOL
Sounder with fitted diode
Output Setting refers to Table List on the Manual
Sounder with built-in diode
Terminal/Output Board
X4
HL5
F1
X5
X6
F2
X7
F3
X1
HL2
HL3
X2
HL4
X3
X8
E AR T H
14
Panel Overview GST-200-2 System Diagram
Stand-alone Architecture
GST200-2/1 – Capacities
•235 devices
•1.0 km max loop length
•1.5mm
2
UTP fire cable
15
Panel Overview GST-200-2 System Diagram
Stand-alone Architecture
GST200-2 – Capacities
•Loop 1 -235 devices
•Loop 2 – 242 devices
•1.0 km max loop length
•1.5mm
2
UTP fire cable
16
Panel Overview GST-200-2 Repeater and GMC connection
Stand-alone Architecture
•Built-in Repeater/Mimic Output
• Up to 10 points
• RS485 – 1000meters
• GSTGMC-up to 8 users
• Required P-9930
•RS232- 15 meters
17
Panels Networking
18
Panels Networking
Network
Fire resistance cable, Min. 1.0mm
2
1.5sqmm UTP cable is recommended.
1200 meters total distance for RS485 network Class B connection
1200 meters distance between two panels for RS485 network Class A connection
3500 meters distance for each branch of CAN network.
19
Panels Networking
RS485 Class A Network
•Maximum 99 FACP
•Recommend 32 FACP
RS 232 Card
Network Card RS 485
(P-9945A)
Length between panels1.2 Km (max)
Network Card RS 485
(P-9940A)
Network Card RS 485
(P-9940A)
Built-in Network Card RS 485
(P-9940A)
20
Panels Networking
CAN Class A Network
•Maximum 99 FACP
•Recommend 32 FACP
RS 232 Card
CAN Network Card
(P-9965A)
CAN Network Card
(P-9960A)
Length between panels 3.5Km (max)
CAN Network Card
(P-9960A)
CAN Network Card
(P-9965A)
CAN Network Card
(P-9960A)
21
Panels Networking
CAN Class B Network
Maximum 240 FACP in whole network.
Maximum 112 FACP in each branch
P-9960
P-9965
CAN HUB
CAN100H-4/8/12/16
P-9960
P-9965
Total Cable Length 3.5 Km (max)
P-9960
P-9965
P-9965
P-9960
22
Panels Networking
Fiber Optic Network
•Maximum 99 FACP
•Recommend 32 FACP
RS485 Class B Fiber Optic Network
Fibre Optic
+
P-9940A
(For Single-Mode-25KM)
Interface FIB485S01
+
P-9945A
(For Multi Mode -4.5km)
Interface FIB485M01
+
P-9940A
+
P-9940A
23
Panels Networking
Fiber Optic Network
•Maximum 99 FACP
•Recommend 32 FACP
RS485 Class A Fiber Optic Network
Fibre Optic
+
P-9940A
(For Single-Mode-25KM)
Interface FIB485S01
+
P-9945A
(For Multi Mode -4.5km)
Interface FIB485M01
Fibre Optic
+
P-9940A
+
P-9940A
24
Panels Networking
TCP/IP Network
+
P-9935 TCPIP + NPort5230
+
P-9935 TCPIP + NPort5230
+
NPort5230 + P-9930TCP/IP
TCP/IP
+
NPort5230 + P-9930TCP/IP
25
Product Overview
26
Initiating Device
Digital Intelligent Sensor
DI-9101E
Intelligent Combination Heat
Photoelectric Smoke Detector
Advance digital communication
Drift compensation, reject false alarm from environment changing, dust accumulation and component aging.
Electrically addressed by handheld programmer
Built-in remote indicator output
Special LED blink under certain degree of dirty; fire alarm when 100% dirty
A2R Heat alarming
Magnetic test
LED blink could be optionally disabled
Detector store most recent 5 fire alarms and fault alarms, as well as total number of alarms.
DB-01
Standard Base
C-9314P
Remote Indicator
27
Initiating Device
Digital Intelligent Sensor
DI-9102E
Intelligent Photoelectric
Smoke Detector
Advance digital communication
Drift compensation, reject false alarm from environment changing, dust accumulation and component aging.
Electrically addressed by handheld programmer
Built-in remote indicator output
Special LED blink under certain degree of dirty; fire alarm when 100% dirty
LED blink could be optionally disabled
Magnetic test
Detector store most recent 5 fire alarms, and fault alarms, as well as total number of alarms.
DB-01
Standard Base
C-9314P
Remote Indicator
28
Initiating Device
Digital Intelligent Sensor
Advance digital communication
A1R/A1S/BS Selectable(LPCB)
Electrically addressed by handheld programmer
Built-in remote indicator output
LED blink could be optionally disabled
Magnetic test
Detector store most recent 5 fire alarms, and fault alarms, as well as total number of alarms.
DI-9103E
Intelligent Rate of Rise and
Fixed Temperature Heat
Detector
DB-01
Standard Base
C-9314P
Remote Indicator
29
Initiating Device
Beam Detector
Infrared beam detector
Detection range 8 to 100 meters
Path width 7 meters each side
1 to 4 reflectors for different path length
Standard EN54-12
Electronically addressed by programmer
Additional Fire and Fault dry contact relay output
24VDC supply required
I-9105R
Reflective Beam Detector
30
Initiating Device
Manual Call Points
Semi-flush or Surface mounted
Standard EN54-11
Re-settable (non-breaking glass)
LED indicator
Electronically addressed by handheld programmer
Friendly installation and test
Optional flipping plastic cover (
D-92FC )
Optional weatherproof box(
D-92WPB )
Optional back box for surface mount
DI-9204E
Digital manual Call Point
D-92FC D-92WPB
31
Notification Device
I-9403
Sounder Strobe
16 selectable tone
High sound level
Low/high power consumption modes
Loop powered or external 24VDC
Max. 30 pieces per loop when powered by loop
High intensity LED cluster
Programmable evacuate only or alert/evacuate mode
Standard EN54-3
Electronically addressed by handheld programmer
Easy installation and connection
C-94DB
Optional deep base for I-9403
32
Notification Device
I-9404
Intelligent Sounder
16 selectable tone
High sound level
Low/high power consumption modes
Loop powered or external 24VDC
Max. 30 pieces per loop when powered by loop
Programmable evacuate only or alert/evacuate mode
Standard EN54-3
Electronically addressed by handheld programmer
Easy installation and connection
C-94DB
Optional deep base for I-9404
33
Notification Device
DI-9405
Addressable
Sounder Base
“sandwich” structure
Termination suitable for
“DI” range detectors
Loop powered
Maximum 30 pieces per loop
Three working modes settable (Mode I, II, III, and the latter two available with pre-alarm state).
16 tones of sound.
Electronically addressed. The address and tones can be modified in field.
Tone 14 and 16 are certified by EN54-3.
34
Notification Device
DI-9406
Addressable
Sounder Beacon Base
“sandwich” structure
Termination suitable for
“DI” range detectors
16 selectable tone
Loop powered
Maximum 30 pieces per loop
Three working modes settable (Mode I, II, III, and the latter two available with pre-alarm state).
16 tones of sound and bright flashing light.
Electronically addressed. The address and tones can be modified in field.
Tone 14 and 16 are certified by EN54-3.
35
Interface
Input Interface
I-9300 Input Module
Intelligent single input module
Monitors switch contacts of remote equipment
Loop Powered
Cable monitored
Standard EN54-18
Electronically addressed by handheld programmer
LED status indicator
36
Interface
Input Interface
I-9319 Zone Interface Module
Intelligent zone monitor module
Interface with conventional fire devices
24VDC required
Cable monitored
Standard EN54-18
Electronically addressed by handheld programmer
LED status indicator
37
Interface
Output Interface
I-9301 Single Output Module
Intelligent single output module
24VDC/3A, 110VAC/3A dry contact output – Loop
Powered
Interface with conventional polarized sounders –
24VDC required
LED status indicator
Standard EN54-18
Electronically addressed by handheld programmer
LED status indicator
38
Isolator
Loop Isolator
C-9503 Short Circuit Isolator
Isolates faulty part of the loop in case short circuit
Auto resume when trouble removed
LED status indicator
Standard EN54-17
Not occupy loop address
39
Isolator
Loop Isolator Base
C-9504 E
Base Mount Short Circuit
Isolator
Termination suitable for “I” range detectors
Isolates faulty part of the loop in case short circuit
Auto resume when trouble removed
LED status indicator
Not occupy loop address
40
Isolator
Loop Isolator Base
Termination suitable for “DI” range detectors
Isolates faulty part of the loop in case short circuit
Auto resume when trouble removed
LED status indicator
Not occupy loop address
DC-9504 E
Base Mount Short Circuit
Isolator
41
Programmer
Handheld Programmer
Set address to loop devices
Change parameter setting of loop device
Program graphic repeater panel LEDs
P-9910B Programmer
42
Repeater Panel
GST-852RP
Passive Repeater Panel
Compatible with all GST intelligent fire alarm control panel
Fire Event Display
Local Sounder mute and Scroll alarm buttons
Connect to RS485 repeater loop
43
Repeater Panel
GST-NRP01
Network Repeater Panel
Display network message (Fire, Plant and Fault)
Achieve remote control of systems
Password protected
Connect in GST panel network
A class A network card already pre-installed
44
Repeater Panel
GST-8903
–A1/A2/A3
Graphic Repeater Panel
Up to 100 LED per module
Custom graphical layout
Display individual points and zone wise fire and fault signal
Display individual points action signal.
Connect to RS485 repeater loop (can be mixed with GST852RP)
45
Graphic Station
GST-GMC
Graphic Monitor Center
Display message (Fire, Fault, Action, Disable)
Remote full control and monitor of systems
Multi-level Password protected
Historic data of all the system events
Clock synchronization with panels
Up to 8 users plus the server in a Network
Connect with panel through RS232 cable
46
Configuration, Operation and
Programming
2014 V1.2
System Configuration
To configure a system
1. Decide panel type and quantity. If more than one panel is configured, add network card to each panel.
2. Decide loop quantity. Remember leave at least 20% of loop quantity for future expansion.
3. Calculate power consumption and configure PSU as required.
4. Consider of loop power consumption devices (like sounder base and loop powered sounder). Add more loop cards if needed.
5. Isolators will be required to protect the loop.
6. At least one handhold programmer and one RS232 communication card is required for each commissioning company.
7. Add any necessary accessories as requirement.
48
Addressable Fire Panel
GST200-2 and GST-IFP8Common Character
Large Graphical LCD display
3 alarm outputs, sounder/F.P.E/Alarm Routing
PAS (Positive Alarm Sequence) and Acknowledge function Advanced user friendly programming software including
“fuzzy logic”
Networkable with all GST Intelligent Fire Alarm panels
Enable and Disable function
Dirty detector report function
Walk test function
Optional RS 232 Color Graphics Software
Optional RS485 Network Card
Optional CAN network card
49
System Configuration
Points for system configuration
1. Max. 32 panels in RS485 network
2. Max. 112 panels in one branch of CAN network. Totally Max. 240 panels.
3. Max. 32 devices between two isolators
4. Max. 30 sounder bases and loop powered sounders (in total) in one loop.
5. Each device occupies one single address, except below devices.
Device Address QTY
C-9503 Loop Isolator
C-9314P Remote Indicator
DI-9309 Multi Input Output Interface
I-9406 Sounder Flasher Base
I-9403 Addressable Sounder Flasher
0
0
3 to 18
1 or 2
1 or 2
50
System Loop Parameter
Loop
•
Fire resistance UTP cable, Min. 1.0mm
2
•
1.5mm
2 UTP cable is recommended.
•
1000 meters loop length
51
System Loop Parameter
Loop cable parameter
Cable resistance should be less than 50
Ω
52
System Loop Parameter
Loop cable parameter
Before fix devices on loop, the resistance between 2core should be more than
2M
Ω, ideally 20MΩ
After fix devices on loop, the resistance between 2 core should be more than 1k
Ω
53
System Loop Parameter
Loop cable parameter
Insulation between cable to
Earth should be more than
20M
Ω, ideally 200MΩ
54
GST200-2 Panel Operation
55
Panel Operation GST200-2
Factory default password
Registration : 24220011
User Operator: 11111111
Manager / System: 11111111
56
Panel Operation GST200-2
Browse Menu
1Loop Devices
2 Zone Devices
3 Group Devices
4In Test Mode Zones
5 Com Devices
6 Access
7 Browsing C&E
Loop Devices: View the number of devices per loop and detailed provided with each device
Zone Devices: View the number of Input devices per zone
Group Device: View number of Output devices per zone
Browse
Zone: 001 GND FLR
No: 003 MCP
Sensitivity: Nominal
Left W ing Corridor
In Test Mode Zones: View which zones are in test mode
COM Devices: View the number of Control Panel and Repeater panel connected in the system
Browse
Sum: 003
Repeater01
Net Unit 01
Net Unit 02
Access: Control switch and zone indicator detailed.
Browsing C&E: View the configured sequence of operation
Browse
Equation 001
S0100103+S0100102
=S01***1312 G011433120
Browse
02 Zone (008)
Zone: 01 (001) 003
Zone : 02 (002) 001
Browse
Sum: 032
N01: Zone 01 (001)
N02: Zone 02 (002)
N03: No Define
57
Panel Operation GST200-2
Mode Menu
1 LCD Contrast
2 Display Mode
3 Print Mode
4 PAS Setup
5 Start Devices
6 Stop Devices
LCD Contrast : (0-100) (factory set
– 50)
Display Mode
1 Zone Mode : by zone detail
2 Loop Mode : by point device detail ( default setting)
Print Mode
1 Disable - ( default setting)
2 Only Fire : Automatic print on fire event
3 All History: Pressing Enter when viewing history records can print out the
messages being viewed
PAS Setup * (Positive Alarm Sequence)
1 Disable- ( default setting)
2 Enable
Start Devices (manually start)
Stop Devices (manually stop)
Start UP
Z001C***T13 Sounder
Stop EQ
Z001C125T03 Optical
58
Panel Operation GST200-2
Mode Menu - PAS
System Requirement (NFPA 72:6.8.1.3)
PAS MODE
Fire signal from detector shall be acknowledged at the panel within 15 sec in order to initiate the alarm investigation phase. Trained personnel shall have up to180 sec to investigate.
•Fire signal not acknowledged w/in 15 sec – Outputs (Equation) immediately activated
•Panel not reset during the 180 sec – Outputs (Equation) immediately activated
•Second fire signal during the 180 sec – Outputs (Equation) immediately activated
Notes:
•Press Evac override PAS
•MCP is exempted (BS5839 P1:2.19)
59
Panel Operation GST200-2
Test Menu
TEST [Operator Password required]
1 Display Test - check the LED and LCD
2 Each Zone In Test
1Display Test
2Each Zone In Test
3 Stop a Zone Test 4
Stop All Zone Test
Start a Zone in Test
Zone: 001
3 Stop a Zone Test
4 Stop All Zones Test
TEST MODE LED will on
Corresponded Zone Yellow LED will lit
60
Panel Operation GST200-2
Disable/Enable Menu
1 Disable Devices
1 Each Zone Fully
2 Individual Point 3
All Loop Sounder
4 Use Device Code
2 Enable Devices
1 Each Zone Fully
2 Individual Point
3 All Loop Sounder
4 Use Device Code
1Disable Devices
2 Enable Devices
3 Dis/En-able Output
4Dis/En-able Delays
5 Delete Net Disable
3 Dis/En-able Output
1 Sounder Circuit
2 F.P.E Output
Disabling a Point
Loop: 1 Point : 001
Enable
Z001C125T03 Optical
4 Dis/En-able Delays:
1 Disable - ( default setting)
By address Using device code
2 Enable- Delay in C&E equations will be effective
5 Delete Net Disable to delete not existing disable messages from network
61
Panel Operation GST200-2
System Menu
1 Time/Date
2 Password Change
1 Operator Password (0-8 digit)
2 Manager Password (0-8 digit)
3 Network Setup
1 Net Local Address (panel network address: 1-240)
2 Net Event Display
1Time/Date
2 Password Change
3 Network Setup
4Zone Start Number
5 Customize
6.Initialize System
7.Devices Debug
1 Disable - (default setting)
2 Enable (To show messages coming from network)
4 Zone Start Number
5 Customize
1 Output Set-up
1 Default Output: ( default setting)
Device type 13 Sounder activate at zone wise alarm .
2 C&E Output: The system output will be based on configured C&E equation
2 PAS Delay (000-180 second)* (factory set is 60 seconds)
3 Re-Sound Configurations
1 Another Zone - ( default setting)
2 Self Zone
6 Initialize System* (Not for common operation)
7 Devices debug * (For factory engineer use)
62
Panel Operation GST200-2 Register
GST200-2
1. Press
“System (9)”
2.
Enter the password
“24220011”
(Factory set Commission Password) then Press
“Enter”
(Note:
“-” sign means the panel is set to commissioning mode)
3. Press
“SK1 button” behind the door.
SYSTEM
1Time/Date
2 Password Change
3 Network Setup
4 Zone Start Number
5 Customize
6Initialize System
7 Device Debug
63
GST200-2 Basic software
Configuration
64
GST Definition software installation
GST Definition software installation Flow Chart
1.GST Def.EXE
2.Windows XP. Double click
“GST Def.exe”, default following steps. Till installation finish
3.install USB driver
Software
Installation
Finish
2.Windows Vista or Windows 7, right click
“GST Def. exe” select
“Run as administrator” , default following steps. Till installation finish.
3.Install USB driver
4.Check computer
OS bits (32 bits or
64 bits), install patch file.
5.Right Click patch file. Select
“Run as administrator
” till installation finish
Right click
“My Computer” select
“property”, pop out window general information showing OS bits
65
GST200-2 Panel addressing
GST200-2 Panel addressing Flow Chart
1. GST200-2 panel, in power off condition
2.Connect RS232 communication card to GST200-2 panel
3.Power on
GST200-2 panel
4.Press panel
“System” button
8.Press
“System” button, input password
“24220011 “ Enter
9.Net work setup
7.Panel restart , during starting progress show
“Color Crt OK”
6.Press SK1 button at back of the main board
5.Input password
10.Net local address
11.Set up panel address . Enter to confirm
Note : Address on panel must be same as the panel address on
GST definition program
24220011
66
Basic Software Configuration GST200-2
GST200-2 Definition Flow Chart
1. Power On
GST200-2
2.Connect download card USB cable to computer USB port
3.Run GST
Definition Software
4.Select Com Port
10.Define
Repeater
(Option)
Save and
Download
9. Define
Zone indication and control switch
Save and
Download
8.Define
Cause &
Effect
7. Define devices
(zone , device type and Location)
Save and
Download
Save and
Download
6.Add zone, define zone
Save and
Download
5.Add panel, select panel type and panel address
Fire Alarm Control Panel GST200-2
67
Basic Software Configuration GST200-2
Points should be known before programming GST 200-2
Each devices code include 3 parts:
Device Zone number (3 digit, range 001-060 for GST200-2
Device address (3 digit, range 001-242)
Device type (2 digit) .
For example: 001001 03 means smoke detector (type 03) address 001 in zone 001
The device code is the device unique ID on standalone FACP or whole FACP network. So before addressing and programming devices, below points should be noted:
1. In same zone, in case the devices from different loop or different panel, the device address + device type can not be same as other device
’s. for example: in zone No.1 already has smoke detector address No.1 from loop1, and in this zone has another smoke detector from other loop or other panel, the device address can not be No.1 again. Or if use address No.1, can not given to smoke detector.
2. Device information transferred on network include :
“Device zone number + Device address + Device type (number only, no text)+ device location description.
So the zone information must be downloaded to each network panel, if has the user defined device type text, the description also need download to each panel.
68
Basic Software Configuration GST200-2
Points should be known before programming GST200-2
1. The maximum zone number for GST200-2 is 60, if the panel in network, and whole network zone numbers more than 60. for example 4 GST200-2 panels in network, each panel include
20 zones. Total 80 zones. The commissioning engineer can set the devices in panel No.1 to zone 1 to 20, devices in panel No.2 to zone 21 to 40, devices in panel No.3 in zone 41 to 60. and devices in panel No.4 in zone 1 to 20, then set the start zone number on panel No.4 is 61. then the zone 1 on panel 4 will be displayed as zone 61 on local and network panel.
2.
On GST200-2 panel, the network fire signal cannot use as local panel Cause & Effect condition.
3.
Local panel can send activation command to network. Such as above example if in case fire on panel 1 want to active module on panel No.4, must save cause & Effect on panel No.1, the activation device code must be the displayed number, for example 061001 13. not the local programmed code.
69
Basic Software Configuration GST200-2
Basic Software Configuration
1. Control Panel Detailed
2. Number of Loop
3. Zone Configuration
4. Device Detailed per Loop /Device Type
5. Equation (Cause & Effect)
6. Control Switch & Zone LED
7. Naming Repeater Panel
8. Saving Data
9. Download / Upload
70
Basic Software Configuration GST200-2
1. Control Panel Detailed
•Adding Control Panel
•Click the “FACP Net” icon
•Right-click “FACP” and select
“Add FACP”
•FACP Type: Select the panel part number
•FACPAddress: Address of the panel
•FACP Name: File name reference
•Net: Click if the panels are network
71
Basic Software Configuration GST200-2
2. Number of Loop
Note:
“Once the GST200-2 is selected, the software is automatically show the two loop, no loop configuration is required
.”
72
Basic Software Configuration GST200-2
3. Zone Configuration
Adding a zone
1.Click the
“FACP Zone” icon
2.Right-click
“Panel that will add zone” and select “Add Zone”
3.Or Click the
“New” icon
Note: Max number of zone is 60
Zone ID : Zone number
ForeColor: Font Color
BackColor: Text Highlight Color
Description: Zone name (note: 8 Max character)
Example: Zone example
4.To save click the
“Save” icon
73
Basic Software Configuration GST200-2
4. Device Detailed
Device Configuration per Loop
1.Click the
“FACP Net” icon
2.Click
“Panel to be programmed”
3.Click the
“Loop 1”
Address: 1-242
Loop Number: Loop Assignment
Zone: Zone assignment
Device Type: Selection of device type.
Properties: For output- 0-on/off ;
1-continoues
Location: Device location information
Note: GST200-2 character 32 max: 21 first line; 11 second line
Registered: Once the data is uploaded from the panel, it will indicate TRUE if the particular device is being found or registered in the panel ,otherwise it will indicate False.
4. Click Save icon to save
74
Basic Software Configuration GST200-2
To configure the Device Type
1.Click the
“Panel that will configure
”
2.Click the
“Device Type –icons
3.The
Device Type window will pop-up
4.Select the number to change and type new Device Type name.
Basic Software Configuration GST200-2
5. Equation ( Cause and Effect )
Configuring the Equation
1. Click the
“FACP Net” icon
2. Click
“Panel to be programmed”
3. Click the
“Equation”
4. Click
“NEW” to create a new equation.
5. To save as a new equation click
“Save New”
1. To overwrite original equation click
“Save
Modify
”
2. To save the entire equation click
“Save”
Condition: INPUT DEVICES- 8 digits
Effect: OUTPUT DEVICES
– 8 digits + 2 digits delay time
Logic: AND Logic (x), OR Logic (+)
Fuzzy Logic: Asterisk (* value 1-9)
Delay Time Ratio: 1:10 seconds
76
Basic Software Configuration GST200-2
5. Equation ( Cause and Effect ) cont.
G/S60
242 99 =
G/S60
242 99 99
Zone *Address
(Fuzzy/Amt)
Device Type Zone Address Device Type Delay Time
Condition
G01 020 03
S02 001 11
(By Zone) meaning Address 20 Optical smoke in Zone 1 (By Point)
(Fuzzy Logic)meaning At least 1 (Amount) MCP regardless of address in Zone 2
S** 002 02
(Global)
(Fuzzy Logic) meaning 2(Amount) Heat det. should alarm at same time in the entire area
Effect:
S**001 31 12 meaning latch all lift module after 2 minutes
–regardless of quantity.
Sample Equation:
S01 001 11 + S01 00103 + S0100102 = S0100113 00 S**00113 06
77
Basic Software Configuration GST200-2
6. Control Switch and LED Zones
Programming control switch
1.Click the
“FACP Net” icon
2.Click
“Panel to be programmed”
3.Click the
“Control Switch”
Keys: 1-30
Address of Device to Start: Select the address of a devices/s that wish to control
Zone to Display: Select the zone number that wish to display
Function: The control switch function-auto change
78
Basic Software Configuration GST200-2
7. Naming Repeater or Mimic Panel
1. Click the
“FACP Net” icon
2. Click the
“Repeater” icon
Based on the address of the repeater type the
Description
3. Click
“Save”
Note: Description- up to 8 characters
79
Basic Software Configuration GST200-2
8. Saving and Restoring the Data
Click the
“Database” icon
The Database Operation window will pop out
Click
“Backup Database” to save the data.
Save the data to the required location
Click
“Restore Database” to retrieve the data.
Locate the saved data
80
Basic Software Configuration GST200-2
9. Upload and Download Data
Terminology:
Download: Data transferring from the PC to the Control Panel
Upload : Data transferring from the Control Panel to the PC
3 important things:
1. Registration of RS232 download card (Hardware)
GST200 Series
Press
“System” Enter the password 24220011 Press “Enter”
Press
“SK1 button” behind the door.
(Note: procedure should be done within 25 seconds and HL1 red LED will blink indicates that the card is registered)
2. Set Serial Port number (USB Connection-My computer-Properties-Hardware-Device Manger-Port)
3. Matched the address of the control panel
“Local Address from the GSTDef software “FACP Address”.
To view the control panels address:
Press
“System”
3 Network Set-up
1 Net Local Address
81
Basic Software Configuration GST200-2
Basic PC Connection Procedures
• Panel must be OFF condition while connecting to the 20p ribbon
1.Turn on the panel and perform an auto learn/registration as follows:
2.Press
“System” Enter the password
“24220011” (Commissioning password) then
Press
“Enter”
3.Press
“SK1 button” behind the door.
(Note: procedure should be done within 25 seconds otherwise the control panel will initialize the normal panel reset)
•After the registration HL1 will be flashing continuously
82