MultiTech MTSMC-H5 Cell HSPA+ SocketModem Cell HSPA+, MTSMC-H5 iCell HSPA+ SocketModem iCell HSPA+, MTSMC-H5 -MI-GP, -MI-IP, -GP, -IP,, -U SocketModem Device Guide
Реклама
Реклама
SocketModem® Cell HSPA+
SocketModem® iCell HSPA+
MTSMC-H5 Device Guide
LEGAL NOTICES AND CONTACT INFORMATION
SocketModem Cell HSPA+ and SocketModem iCell HSPA+ MTSMC-H5 Device Guide
S000540, Version G
MTSMC-H5-xx, MTSMC-H5-U-xx, MTSMC-H5-IP-xx, MTSMC-H5-GP-xx, MTSCMC-H5-MI-IP-xx, MTSMC-H5-MI-GP
Copyright
This publication may not be reproduced, in whole or in part, without the specific and express prior written permission signed by an executive officer of
Multi-Tech Systems, Inc. All rights reserved. Copyright © 2016 by Multi-Tech Systems, Inc.
Multi-Tech Systems, Inc. makes no representations or warranties, whether express, implied or by estoppels, with respect to the content, information, material and recommendations herein and specifically disclaims any implied warranties of merchantability, fitness for any particular purpose and non-infringement.
Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of
Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes.
Trademarks
MultiTech is a trademark of and SocketModem, SocketWireless, Universal IP, SocketEthernet IP and the Multi-Tech logo are registered trademarks of
Multi-Tech Systems, Inc. All other brand and product names are trademarks or registered trademarks of their respective companies.
Legal Notices
The MultiTech products are not designed, manufactured or intended for use, and should not be used, or sold or re-sold for use, in connection with applications requiring fail-safe performance or in applications where the failure of the products would reasonably be expected to result in personal injury or death, significant property damage, or serious physical or environmental damage. Examples of such use include life support machines or other life preserving medical devices or systems, air traffic control or aircraft navigation or communications systems, control equipment for nuclear facilities, or missile, nuclear, biological or chemical weapons or other military applications (“Restricted Applications”). Use of the products in such Restricted
Applications is at the user’s sole risk and liability.
MULTITECH DOES NOT WARRANT THAT THE TRANSMISSION OF DATA BY A PRODUCT OVER A CELLULAR COMMUNICATIONS NETWORK WILL BE
UNINTERRUPTED, TIMELY, SECURE OR ERROR FREE, NOR DOES MULTITECH WARRANT ANY CONNECTION OR ACCESSIBILITY TO ANY CELLULAR
COMMUNICATIONS NETWORK. MULTITECH WILL HAVE NO LIABILITY FOR ANY LOSSES, DAMAGES, OBLIGATIONS, PENALTIES, DEFICIENCIES, LIABILITIES,
COSTS OR EXPENSES (INCLUDING WITHOUT LIMITATION REASONABLE ATTORNEYS FEES) RELATED TO TEMPORARY INABILITY TO ACCESS A CELLULAR
COMMUNICATIONS NETWORK USING THE PRODUCTS.
The MultiTech products and the final application of the MultiTech products should be thoroughly tested to ensure the functionality of the MultiTech products as used in the final application. The designer, manufacturer and reseller has the sole responsibility of ensuring that any end user product into which the MultiTech product is integrated operates as intended and meets its requirements or the requirements of its direct or indirect customers.
MultiTech has no responsibility whatsoever for the integration, configuration, testing, validation, verification, installation, upgrade, support or maintenance of such end user product, or for any liabilities, damages, costs or expenses associated therewith, except to the extent agreed upon in a signed written document. To the extent MultiTech provides any comments or suggested changes related to the application of its products, such comments or suggested changes is performed only as a courtesy and without any representation or warranty whatsoever.
Contacting MultiTech
Knowledge Base
The Knowledge Base provides immediate access to support information and resolutions for all MultiTech products. Visit http://www.multitech.com/kb.go.
Support Portal
To create an account and submit a support case directly to our technical support team, visit: https://support.multitech.com
.
Support
Business Hours: M-F, 9am to 5pm CT
Country
Europe, Middle East, Africa:
U.S., Canada, all others:
World Headquarters
Multi-Tech Systems, Inc.
2205 Woodale Drive
Mounds View, Minnesota 55112
Phone: 763-785-3500 or 800-328-9717
Fax: 763-785-9874
By Email [email protected] [email protected]
By Phone
+(44) 118 959 7774
(800) 972-2439 or (763) 717-5863
Warranty
To read the warranty statement for your product, please visit: http://www.multitech.com/warranty.go.
SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide 2
3
CONTENTS
Contents
SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide
CONTENTS
SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide 4
5
CHAPTER 1 – DEVICE OVERVIEW
Chapter 1 – Device Overview
Description
The SocketModem Cell and iCell HSPA+ models are complete, ready-to-integrate communications devices that offer standards-based HSPA+ 21 performance. These quick-to-market communications devices allow developers to add wireless communication and GPS tracking to products with a minimum of development time and expense.
Both models are based on industry-standard open interfaces and use MultiTech’s Universal Socket design. The
SocketModem iCell features the intelligence of the embedded Universal IP stack, which allows for automatic/persistent connectivity for mission critical applications and enhanced M2M functionality.
Product Build Options
Product
MTSMC-H5-MI-GP
MTSMC-H5-MI-IP
MTSMC-H5-GP
MTSMC-H5-IP
MTSMC-H5
MTSMC-H5-U
Description
Global HSPA+ 21M - Data Only, MTS GPS,
Serial, USB, GPIO, Universal IP
Global HSPA+ 21M - Data Only, Serial,
USB, GPIO, Universal IP
Global HSPA+ 21M - Data Only, MTS GPS,
Serial, Universal IP
Global HSPA+ 21M - Data Only, Serial,
Universal IP
Global HSPA+ 21M - Data Only, Serial
Global HSPA+ 21M - Data Only, USB
Region
US
Europe
Canada
Australia
US
Europe
Canada
Australia
US
Europe
Canada
Australia
US
Europe
Canada
Australia
US
Europe
Canada
Australia
US
Europe
Canada
Australia
Developer Kit
MTSMI-UDK Universal Developer Kit Global
SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide
CHAPTER 1 – DEVICE OVERVIEW
Notes:
These units ship without network activation. To connect them to the cellular network, you need a cellular account. For more information, refer to Account Activation for Cellular Devices in the Universal Socket
Developer’s Guide.
GP devices have a dedicated GPS receiver.
MI devices have multiple interfaces.
The complete product code may end in .Rx. For example, MTSMC-H5.Rx, where R is revision and x is the revision number.
All builds can be ordered individually or in 50-packs.
Documentation
The following documentation is available by email to [email protected]
or by using the Developer Guide
Request Form on the multitech.com
Device Guide – This document. Provides model-specific specifications and developer information.
Universal Socket Developer Guide – Provides an overview, safety and regulatory information, design considerations, schematics, and general device information. (S000342)
USB Driver Installation Guide for H5 and G3 Devices – Provides steps for installing USB drivers. (S000533)
AT Command Guide – Use the following AT Command Guides with HSPA devices:
S000574 for H5-xx.R1 Modems
80378ST10091A Rev 9 Telit 3G Modules AT Commands Guide for H5-xx.R2 Modems
S000528 for H5-xx Modems (not .R1 or .R2)
S000457 Universal IP Commands
SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide 6
CHAPTER 3 – SPECIFICATIONS
Chapter 2 – Mechanical Drawing
MTSMC-H5 All Builds
7 SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide
Chapter 3 – Specifications
CHAPTER 3 – SPECIFICATIONS
Technical Specifications
Category
General
Standards
Description
Frequency Bands
Penta-band HSPA+ 21
Quad-band GSM/GPRS/EDGE
SMS is based on CS/Packet-Switched (PS) domain of GSM and WCDMA
USB Interface is CDC-ACM compliant
Penta-band HSPA+: 850/900/1700/1900/2100 MHz
Quad-band GSM/GPRS/EDGE: 850/900/1800/1900 MHz
Speed
Data Speed HSPA+: Up to 21.0 Mbps downlink/5.76 Mbps uplink
EDGE: Up to 296 Kbps downlink/236.8 Kbps uplink
GPRS: Up to 107 Kbps downlink/85.6 Kbps uplink
Interface, Ports
USB Interface
Weight
Dimensions
Connectors
MI builds: USB 2.0 full speed
High speed on other builds: 480 Mbps
Serial Modem Interface Up to 921.6 Kbps
Ports
Physical Description
GPIO ports – MI builds only
0.4 oz. (10g)
Refer to mechanical drawing for details.
Antenna Connector
SIM Holder
Environment
3 surface mount UFL: cellular, GPS, RX diversity
Standard 1.8V and 3V.
Operating Temperature -40° C to +85° C
Storage Temperature -40° C to +85° C
Humidity 20%-90% RH, non-condensing
Power Requirements
Operating Voltage
Input Power
3.3V - 5V
3.3 - 5VDC
IP, M2M, SMS
Supported IP Protocols DNS resolve, FTP client, Ping, POP3 client, PPP (dialout), SMTP client, TCP RAW client & server
M2M Applications
SMS
Universal IP models: Automatic connect/reconnect, device monitor, modem emulation,
Ping & TCP keep alive, wake-up on caller ID, wake-up on ring, GPS tracking (GP model only)
Point-to-Point messaging
Mobile-Terminated SMS
Mobile-Originated SMS
SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide 8
9
CHAPTER 3 – SPECIFICATIONS
Category Description
Certifications, Compliance, Warranty
EMC Compliance
Radio Compliance
FCC Part 15 Class B
FCC Part 15.31 (Co-location)
EN55022 Class B
EN55024
FCC Part 22
FCC Part 24
RSS 132
RSS 133
EN 301 511
EN 301 489-1
EN 301 489-7
EN 301 489-24
Safety Compliance
Network Compliance
Warranty
UL 60950-1 cUL 60950-1
EN 60950-1
AS/NZS 60950-1
PTCRB
AT&T
Two years
Notes:
Radio performance may be affected by temperature extremes. This is normal. The radio is designed to automatically fallback in class and reduces transmitter power to avoid damage to the radio. When this occurs depends on the interaction of several factors, such as ambient temperature, operating mode, and transmit power.
Mounting Hardware
The board has three mounting holes at corners. Use #4 or M3 hardware for mounting the SocketModem to the board. Refer to the Mechanical Drawings for more information.
Recommended Parts
Manufacturer
PEM PennEngineering
RAF Electronic Hardware
RAF Electronic Hardware
Part
Surface Mount Standoff
3/16” Hex Female Standoff
4.5mm Hex Female Standoff
Part Number
SMTSO-M3-4ET
2051T-440-S-12-Zinc
1251-3005-S-12-Zinc
SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide
CHAPTER 3 – SPECIFICATIONS
Device Reset
The SocketModem is ready to accept commands after a fixed amount of time (“X” Time) after power-on or reset.
Model
MTSMC-H5
Time Constant
250 ms
"X" Time
10 seconds
1
The SocketModem may respond to a shorter reset pulse.
Minimum Reset Pulse
1
Maximum Reset Pulse
200 µs Less than 1 second
Powering Down Your Device
CAUTION:
Failing to properly shutdown the device before removing power may corrupt your device's file system.
To properly power down your device, use the following sequence:
1. Issue the AT#SHDN command.
2. Wait 30 seconds.
3. Power off the device. Disconnect power from the device.
Serial Signal DC Electrical Characteristics
Units:
Volts
Applies to the following pins:
Pin Signal Name Pin Signal Name
J33 -RTS
J34 -RXD
J37
J38
-DSR
-CTS
J35 -TXD
J36 -RI
J39 -DCD
J40 -DTR
Minimum Parameter
3.3 Volt Powered
Input Low Level
Input High Level
Output Low Level
Output High Level
5 Volt Powered
Input Low Level
Input High Level
Output Low Level
Output High Level
0
1.5
0
2.35
0
2.3
0
3.7
Maximum
0.55
3.3
0.55
3.3
0.8
5
0.55
5
Absolute Maximum Rating
All models can run with an input voltage of either 3.3V or 5V. The maximum voltage on any signal pin equals the input voltage.
Electrical Characteristics Other Pins
SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide 10
CHAPTER 3 – SPECIFICATIONS
Pin Signal Name
J24
J25
J26
J27
J28
J41
J48
Pin
J49
J50
J51
J58
J61
J63
-RESET
USB VBUS
GND
USB DP
USB DN
GND
GPIO0
Signal Name
GPIO1
GPIO2
GPIO3
-LED LINK
VCC
GND
VIL VIH VOL VOH
Min Max Min Max Min Max Min Max
0.8 2.0 -- -- -- --
-0.3 0.8 2.0 8.7 --
-- -- -- -- --
0.8 2
--
--
--
--
0.3 2.8
--
--
--
0.8
--
2
-- --
-0.3 0.8 2.0 5.5
--
0.3 2.8
-- -- --
0.4 2.9
VIL VIH VOL VOH
Min Max Min Max Min Max Min Max
-0.3 0.8 2.0 5.5 0.4 2.9
-0.3 0.8 2.0 5.5
-0.3 0.8 2.0 5.5
-- -- -- -- 0
--
--
--
--
--
--
--
--
--
--
0.4 2.9
0.4 2.9
0.45 2.85 3.3
--
--
--
--
--
--
Pinout Specifications
Pin Signal Name Logic Level Voltage
1
I/O
J24 –RESET 3.3 – 5.0 I
J25 USB VBUS
J26 GND
J27 USB DP
3.3 – 5.0
GND
3.3
I
GND
I/O
J28 USB DN
J33 –RTS
J34 –RXD
J35 –TXD
J36 –RI
J37 –DSR
J38 –CTS
J39 –DCD
3.3
5.0
5.0
5.0
5.0
5.0
5.0
5.0
I
O
O
O
O
I/O
I
O
J40 –DTR
J41 GND
J48 GPIO0
J49 GPIO1
J50 GPIO2
J51 GPIO3
5.0
GND
3.3
3.3
3.3
3.3
I
GND
I/O
I/O
I/O
I/O
J58 –LED LINK
J61 VCC
3.3
5.0
O
PWR
J63 GND GND GND
1
A hyphen (-) indicates a range of acceptable logic levels.
Description
Device reset (active low)
USB power supply input
Ground
USB data
USB data
Request to send (active low)
Received data (active low)
Transmitted data (active low)
Ring indicator (active low)
Data set ready (active low)
Clear to send (active low)
Data carrier detect (active low)
Data terminal ready (active low)
Ground
User configurable general purpose I/O
User configurable general purpose I/O
User configurable general purpose I/O
User configurable general purpose I/O
Link status (active low, can sink up to 150mA)
DC input power
Ground
11 SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide
CHAPTER 3 – SPECIFICATIONS
Pin 58
Note:
Pin 58 may or may not be available on some SocketModems.
Pin 58 LED Mode
OFF
Operating Status
Subscriber Carrier Mode is OFF or running in SLEEP or ALARM mode.
600 ms ON/600ms OFF No SIM card inserted, no PIN entered, network search in progress, ongoing user authentication, or network login in progress.
75 ms ON / 75 ms OFF /
75 ms ON
3 s OFF
Flashing or Blinking
ON
One or more EDGE/GPRS/CDMA contexts activated. Indicates EDGE/GPRS/CDMA data transfer: When a transfer is in progress, the LED goes on within 1 second after data packets were exchanged.
Flash duration is approximately 0.5 s.
Depending on call type:
Voice Call: Connected to remote party.
Data Call: Connected to remote party or parameter exchange while call is set up or disconnected.
Pin Availability by Build
Pin and Function MI-IP/GP
J24 Reset
J25 USB_VBUS
J26 GND x x x
J27 USB_DP
J28 USB_DN
J33 -RTS x x x
J34 -RXD
J35 -TXD
J36 -RI
J37 -DSR
J38 -CTS
J39 -DCD
J40 -DTR
J41 GND x x x x x x x x
J48 GPIO
J49 GPIO
J50 GPIO
J51 GPIO
J58 -LED LINK
J61 VCC
J63 GND x x x x x x x x x x x x x x x x
IP/GP
x x x x x x x x x x x x x x x
Serial only USB only
x x x x x x x x x x x
SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide 12
CHAPTER 3 – SPECIFICATIONS
Power Measurements
MultiTech recommends that you incorporate a 10% buffer into your power source when determining product load.
MTSMC-H5
Radio Protocol AT command used to set radio function and power mode
Time (sec) to reduced power from command or DTE signal change
Time (sec) to “ready for data connection” from reduced power
Registered Power
Radio Idle, SIM installed and connected to tower
3.3 Volts
GSM850/HSDPA AT+CFUN=1 N/A N/A 30mA
AT+CFUN=5
AT+CFUN=7
5 Volts
GSM850/HSDPA AT+CFUN=1
Approx. 1 second
Approx. 1 second
Approx. 1 second
Approx. 2 seconds
17mA
17mA/30mA
AT+CFUN=5
AT+CFUN=7
N/A
Approx. 1 second
Approx. 1 second
N/A
Approx. 1 second
Approx. 2 seconds
28mA
19mA
17mA/30mA
Radio
Protocol
Measured
Current
(Amps)
Low Power
MS Xmit or Power
Cntrl
Level
3.3 Volts
GSM850 100mA
28
HSDPA 286mA Alternating
Bits
GSM Xmit
Power or
HSDPA Ch
Power
Meas.
(avg)
4.70
N/A
Measured
Current
(Amps)
Half Power
MS Xmit or
Power
Cntrl
Level
104mA 15
288mA Active
Bits
GSM Xmit
Power or
HSDPA Ch
Power
Meas.
(avg)
13
N/A
Measured
Current
(Amps)
Max Power
MS Xmit or
Power
Cntrl
Level
481mA 0
610mA All Up
Bits
5 Volts
GSM850 72mA
28
HSDPA 162mA Alternating
Bits
4.75
N/A
74mA 15
173mA Active
Bits
13.02
N/A
226mA 0
397mA All Up
Bits
Note:
This data is measured using an Agilent call box connected to the cellular radio.
GSM Xmit
Power or
HSDPA Ch
Power
Meas.
(avg)
32.9
N/A
32.88
N/A
13 SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide
CHAPTER 3 – SPECIFICATIONS
Radio
Protocol
Instant Peak TX
Current (Amps)
Peak Reset Current
(InRush) (Amps)
Peak Reset Current
(InRush) Duration
3.3 Volts
GSM850
HSDPA
5 Volts
3.81A
700mA
1.82A
1.82A
3.68ms
3.68ms
GSM850
HSDPA
Notes:
1.73A
390mA
1.95A
1.95A
3.12ms
3.12ms
AT+CFUN=1 used to set radio function and power mode.
Instant Peak Tx: The peak current during a GSM850 transmission burst period or HSDPA connection. This current is handled by bulk capacitance in a design.
Measured Current: The continuous current during a Transmit with the radio transmitter at specified power.
Inrush Current: The input current during power up, or a reset.
Registered Power: Registered to tower. Receive active for SMS. No data is sent.
MTSMC-H5-U
Radio Protocol AT command used to set radio function and power mode
Registered Power Radio Idle, SIM installed and connected to tower
3.3 Volts
GSM850/HSDPA
5 Volts
GSM850/HSDPA
AT+CFUN=1
AT+CFUN=1
62mA
46mA
Radio
Protocol
Measured
Current
(Amps)
Low Power
MS Xmit or
Power
Control
Level
GSM Xmit
Power or
HSDPA Ch
Power
Meas.
(avg)
3.3 Volts
GSM850 126mA 28 4.70
HSDPA 250mA Alternating bits
5 Volts
130mA
Half Power
Measured
Current
(Amps)
MS Xmit or Power
Control
Level
15
294mA Active bits
GSM Xmit
Power or
HSDPA Ch
Power
Meas.
(avg)
13
Measured
Current
(Amps)
492mA
Max Power
MS Xmit or
Power
Control
Level
0
672mA All up bits
GSM850 81mA 28 4.75 89mA 15 13.02 231mA 0
HSDPA 163mA Alternating bits
192mA Active bits
416mA All up bits
Note: This data is measured using an Agilent call box connected to the cellular radio.
GSM Xmit
Powr or
HSDPA Ch
Power
Meas.
(avg)
32.9
32.88
SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide 14
CHAPTER 3 – SPECIFICATIONS
Radio
Protocol
Instant Peak TX
Current (Amps)
Peak Reset Current
(InRush) (Amps)
Peak Reset Current
(InRush) Duration
3.3 Volts
GSM850
HSDPA
5 Volts
3.53A
620mA
2.14A
2.14A
4.80ms
4.80ms
GSM850
HSDPA
Notes:
1.48A
407mA
2.11A
2.11A
3.00ms
3.00ms
The USB model does not have sleep mode.
AT+CFUN=1 used to set radio function and power mode.
Instant Peak Tx: The peak current during a GSM850 transmission burst period or HSDPA connection. This current is handled by bulk capacitance in a design.
Measured Current: The continuous current during a Transmit with the radio transmitter at specified power.
Inrush Current: The input current during power up or a reset.
Registered Power: Registered to tower. Receive active for SMS. No data is sent.
MTSMC-H5-IP
Radio Protocol AT command used to set
Radio Registration Data radio function
Peak Current and power mode
Amplitude during radio registration
Peak Current
Pulse Duration during radio
Time (sec) to
Peak
Registration
(Amps) registration Current Pulse
Radio Idle, SIM installed and connected to tower
(Amps)
3.3 Volts
GSM850
HSDPA
AT+CFUN=1
AT+CFUN=1
2.2A
N/A
.720ms
N/A
54
N/A
0.117mA
0.115mA
5 Volts
GSM850
HSDPA
AT+CFUN=1
AT+CFUN=1
1.11A
N/A
.720ms
N/A
54
N/A
0.078mA
0.078mA
Radio
Protocol
Measured
Current
(Amps)
Low Power
MS Xmit or Power
Cntrl
Level
GSM Xmit
Power or
HSDPA Ch
Power
Meas.
(avg)
3.3 Volts
GSM850 0.173mA 28
4
HSDPA 0.262mA All Down N/A
Measured
Current
(Amps)
Half Power
MS Xmit or
Power
Cntrl
Level
GSM Xmit
Power or
HSDPA Ch
Power
Meas.
(avg)
0.178mA 15 12.4
0.318mA Active N/A
Max Power
Measured
Current
(Amps)
MS Xmit or
Power
Cntrl
Level
GSM Xmit
Power or
HSDPA Ch
Power
Meas.
(avg)
0.566mA 0 31.7
0.804mA All Up N/A
15 SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide
CHAPTER 3 – SPECIFICATIONS
Radio
Protocol
Measured
Current
(Amps)
Low Power
MS Xmit or Power
Cntrl
Level
GSM Xmit
Power or
HSDPA Ch
Power
Meas.
(avg)
5 Volts
GSM850 0.114mA
28 4
HSDPA 0.169mA All Down N/A
Measured
Current
(Amps)
Half Power
MS Xmit or
Power
Cntrl
Level
GSM Xmit
Power or
HSDPA Ch
Power
Meas.
(avg)
0.116mA 15 12.4
0.211mA Active N/A
Max Power
Measured
Current
(Amps)
MS Xmit or
Power
Cntrl
Level
GSM Xmit
Power or
HSDPA Ch
Power
Meas.
(avg)
0.275mA 0 31.7
0.476mA All Up N/A
Note:
This data is measured using an Agilent call box connected to the cellular radio.
Radio
Protocol
Peak Amplitude
TX Current
(Amps) for
GSM850 or Peak
Current for
HSDPA
Peak Current during power up (InRush
Amps)
Peak Current
Duration during powerup
(InRush duration)
Peak Current during Reset
(InRush Amps)
3.3 Volts
GSM850
3.37A 3.84 2.04ms 3.31A
HSDPA
0.856mA 3.84 2.04ms N/A
5 Volts
Peak Current Duration during Reset (InRush
Duration)
0.640ms
N/A
GSM850
HSDPA
Notes:
1.95A
0.536mA
3.78
3.78
2.00ms
2.00ms
1.73A
N/A
0.560ms
N/A
AT+CFUN=1 used to set radio function and power mode.
Instant Peak Tx: The peak current during a GSM850 transmission burst period or HSDPA connection. This current is handled by bulk capacitance in a design.
Measured Current: The continuous current during a Transmit with the radio transmitter at specified power.
Inrush Current: The input current during power up, or a reset.
Registered Power: Registered to tower. Receive active for SMS. No data is sent.
SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide 16
CHAPTER 3 – SPECIFICATIONS
MTSMC-H5-GP
Radio Protocol
AT command used to set
Radio Registration Data radio function
Peak Current and power mode
Amplitude during
Peak Current
Pulse Duration
Time (sec) to
Peak radio registration during radio Registration
(Amps) registration Current Pulse
Radio Idle, SIM installed and connected to tower
(Amps)
3.3 Volts
GSM850
HSDPA
5 Volts
GSM850
HSDPA
AT+CFUN=1
AT+CFUN=1
AT+CFUN=1
AT+CFUN=1
2.37A
N/A
1.2A
N/A
.760ms
N/A
.460ms
N/A
10
N/A
10
N/A
0.24mA
0.241mA
0.155mA
0.155mA
Radio
Protocol
Measured
Current
(Amps)
Low Power
MS Xmit or Power
Cntrl
Level
GSM Xmit
Power or
HSDPA Ch
Power
Meas.
(avg)
3.3 Volts
GSM850 0.308mA 28
3.5
HSDPA 0.395mA All Down N/A
Measured
Current
(Amps)
Half Power
MS Xmit or
Power
Cntrl
Level
GSM Xmit
Power or
HSDPA Ch
Power
Meas.
(avg)
0.313mA 15 12.1
0.457mA Active N/A
Max Power
Measured
Current
(Amps)
MS Xmit or
Power
Cntrl
Level
GSM Xmit
Power or
HSDPA Ch
Power
Meas.
(avg)
0.731mA 0 31.9
1.15mA All Up N/A
5 Volts
GSM850 0.197mA
28 3.5
HSDPA 0.249mA All Down N/A
0.198mA 15 12.1
0.286mA Active N/A
0.358mA 0 31.9
0.678mA All Up N/A
Note:
This data is measured using an Agilent call box connected to the cellular radio.
Radio
Protocol
Peak Amplitude TX
Current (Amps) for
GSM850 or Peak
Current for HSDPA
Peak Current during power up (InRush
Amps)
Peak Current
Duration during powerup (InRush duration)
Peak Current during Reset
(InRush Amps)
3.3 Volts
GSM850
HSDPA
3.56A
1.236A
3.96A
3.96A
2.00ms
2.00ms
2.4A
2.4A
5 Volts
1.92A
0.728mA
3.96A
3.96A
1.88ms
1.88ms
1.2A
1.2A
GSM850
HSDPA
Peak Current
Duration during
Reset (InRush
Duration)
0.760ms
0.760ms
0.400ms
0.400ms
17 SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide
CHAPTER 3 – SPECIFICATIONS
Notes:
AT+CFUN=1 used to set radio function and power mode.
Instant Peak Tx: The peak current during a GSM850 transmission burst period or HSDPA connection. This current is handled by bulk capacitance in a design.
Measured Current: The continuous current during a Transmit with the radio transmitter at specified power.
Inrush Current: The input current during power up, or a reset.
Registered Power: Registered to tower. Receive active for SMS. No data is sent.
MTSMC-H5-MI-IP
Radio Protocol AT command Radio Registration Data used to set radio function
Peak Current and power mode
Amplitude during
Peak Current
Pulse Duration
Time (sec) to
Peak radio registration during radio Registration
(Amps) registration Current Pulse
Radio Idle, SIM installed and connected to tower
(Amps)
3.3 Volts
GSM850
HSDPA
5 Volts
GSM850
HSDPA
AT+CFUN=1
AT+CFUN=1
AT+CFUN=1
AT+CFUN=1
1.9A
N/A
0.911A
N/A
.390ms
N/A
.390ms
N/A
32
N/A
32
N/A
0.123mA
0.123mA
0.081mA
0.081mA
Radio
Protocol
Measured
Current
(Amps)
Low Power
MS Xmit or Power
Cntrl
Level
GSM Xmit
Power or
HSDPA Ch
Power
Meas.
(avg)
3.3 Volts
GSM850 0.179mA 28
3.8
HSDPA 0.265mA All Down N/A
Measured
Current
(Amps)
Half Power
MS Xmit or
Power
Cntrl
Level
GSM Xmit
Power or
HSDPA Ch
Power
Meas.
(avg)
0.185mA 15 12.4
0.321mA Active N/A
5 Volts
GSM850 0.12mA
28 3.8
HSDPA 0.174mA All Down N/A
0.122mA 15
0.211mA Active
12.4
N/A
Max Power
Measured
Current
(Amps)
MS Xmit or
Power
Cntrl
Level
GSM Xmit
Power or
HSDPA Ch
Power
Meas.
(avg)
0.669mA 0 32
0.831mA All Up N/A
0.264mA 0
0.502mA All Up
32
N/A
Note:
This data is measured using an Agilent call box connected to the cellular radio.
SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide 18
CHAPTER 3 – SPECIFICATIONS
Radio
Protocol
Peak Amplitude
TX Current
(Amps) for
GSM850 or Peak
Current for
HSDPA
Peak Current during power up (InRush
Amps)
Peak Current
Duration during powerup
(InRush duration)
Peak Current during Reset
(InRush Amps)
Peak Current Duration during Reset (InRush
Duration)
3.3 Volts
GSM850
HSDPA
5 Volts
2.33A
0.904mA
2.33
2.23
1.41ms
1.41ms
3.31A
N/A
0.400ms
N/A
GSM850
1.22A 2.95 1.68ms 1.23A 0.360ms
HSDPA
Notes:
0.572mA 2.95 1.68ms N/A N/A
AT+CFUN=1 used to set radio function and power mode.
Instant Peak Tx: The peak current during a GSM850 transmission burst period or HSDPA connection. This current is handled by bulk capacitance in a design.
Measured Current: The continuous current during a Transmit with the radio transmitter at specified power.
Inrush Current: The input current during power up, or a reset.
Registered Power: Registered to tower. Receive active for SMS. No data is sent.
MTSMC-H5-MI-GP
Radio Protocol AT command used to set
Radio Registration Data radio function
Peak Current and power mode
Amplitude during radio registration
Peak Current
Pulse Duration during radio
Time (sec) to
Peak
Registration
(Amps) registration Current Pulse
Radio Idle, SIM installed and connected to tower
(Amps)
3.3 Volts
GSM850
HSDPA
AT+CFUN=1
AT+CFUN=1
2.37A
N/A
.400ms
N/A
28
N/A
0.238mA
0.238mA
5 Volts
GSM850
HSDPA
AT+CFUN=1
AT+CFUN=1
1.07A
N/A
.400ms
N/A
28
N/A
0.157mA
0.156mA
19 SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide
CHAPTER 3 – SPECIFICATIONS
Radio
Protocol
Measured
Current
(Amps)
Low Power
MS Xmit or Power
Cntrl
Level
GSM Xmit
Power or
HSDPA Ch
Power
Meas.
(avg)
3.3 Volts
GSM850 0.295mA 28
3.7
HSDPA 0.386mA All Down N/A
Measured
Current
(Amps)
Half Power
MS Xmit or
Power
Cntrl
Level
GSM Xmit
Power or
HSDPA Ch
Power
Meas.
(avg)
0.3mA 15 12.6
0.445mA Active N/A
Max Power
Measured
Current
(Amps)
MS Xmit or
Power
Cntrl
Level
GSM Xmit
Power or
HSDPA Ch
Power
Meas.
(avg)
0.862mA 0 31.8
0.945mA All Up N/A
5 Volts
GSM850 0.195mA
28 3.7
HSDPA 0.253mA All Down N/A
0.198mA 15 12.6
0.290mA Active N/A
0.368mA 0 32.1
0.581mA All Up N/A
Note:
This data is measured using an Agilent call box connected to the cellular radio.
Radio
Protocol
Peak Amplitude TX
Current (Amps) for
GSM850 or Peak
Current for HSDPA
Peak Current during power up (InRush
Amps)
Peak Current
Duration during powerup (InRush duration)
Peak Current during Reset
(InRush Amps)
3.3 Volts
GSM850
HSDPA
2.500A
1.036A
2.18A
2.18A
1.48ms
1.48ms
3.59A
N/A
5 Volts
Peak Current
Duration during
Reset (InRush
Duration)
0.400ms
N/A
GSM850
HSDPA
Notes:
1.560A
0.656mA
2.95A
2.95A
1.60ms
1.60ms
1.51A
N/A
0.400ms
N/A
AT+CFUN=1 used to set radio function and power mode.
Instant Peak Tx: The peak current during a GSM850 transmission burst period or HSDPA connection. This current is handled by bulk capacitance in a design.
Measured Current: The continuous current during a Transmit with the radio transmitter at specified power.
Inrush Current: The input current during power up, or a reset.
Registered Power: Registered to tower. Receive active for SMS. No data is sent.
SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide 20
CHAPTER 3 – SPECIFICATIONS
Additional Information for the MTSMC-H5 Serial Device
Mode
IDLE mode (WCDMA)
AT+CFUN=5
Average (mA)
17ma
IDLE mode (GSM/EDGE
)
AT+CFUN=1 30ma
AT+CFUN=5
Reset hold
AT+CFUN=7
Operative mode (WCDMA)
17ma
13ma
17-30
WCDMA HSPA+ (0dBm) 286
WCDMA HSPA+ (22dBm) 610
Operative mode (EDGE)
EDGE 4TX+2RX
GSM900 PL5
DCS1800 PL0
Operative mode (GSM)
GPRS 4TX+2RX
GSM900 PL5
DCS1800 PL0
495
484
580
438
Mode description
Full Function with power save
Normal mode: full functionality of the module
Full function with power save.
Deep sleep mode. Need to hold unit in reset event until wake up. Disabled TX and RX and AT commands.
Full Function w/periodic power save.
WCDMA data call (Cat 14, TX = 0dBm)
WCDMA data call (Cat 14, TX = 22dBm)
EDGE Sending data mode
GPRS Sending data mode
Set Phone and Registration Functionality +CFUN
AT+CFUN=[<fun>[,<rst>]] Sets the functionality level in the ME.
<fun>
0
Power saving function mode.
+CFUN=0 is not operational. The board wakes it.
1
Mobile full functions with power saving disabled. Default: 1.
4
5
7
<rst>
0
Disable both TX and RX.
Mobile full functions with power saving enabled.
CYCLIC SLEEP mode. In this mode, the serial interface is periodically enabled while CTS is active. If characters are recognized on the serial interface, the ME stays active for 2 seconds after the last character was sent or received. ME exits SLEEP mode only, if AT+CFUN=1 is entered.
Reset flag.
Do not reset the ME before setting it to <fun> function level.
1
Reset the device. The device is fully functional after the reset. This value is available only for <fun> = 1
21 SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide
CHAPTER 3 – SPECIFICATIONS
Notes
Issuing AT+CFUN=4[,0] actually causes the device to perform either a network deregistration or a SIM deactivation.
Enabling power saving reduces power consumption during idle time, thus allowing a longer standby time with a given battery capacity.
To place the device in power saving mode, set the <fun> parameter to value = 5 and the line DTR (RS232) to
OFF.
Once in power saving, the CTS line switch to the OFF status to signal that the device is really in power saving condition.
During the power saving condition, before sending any AT command on the serial line, set the DTR to ON
(0V) to exit from power saving and wait for the CTS (RS232) line to go in ON status.
Power saving does not affect the network behavior of the device. Even during the power save condition the device remains registered on the network and reachable for incoming calls or SMS. If a call comes in during the power save, the device will wake up and proceed normally with the unsolicited incoming call code.
When the device detects a connected USB port, the power saving mode is not allowed.
In CYCLIC SLEEP mode (AT+CFUN=7) CTS line toggles slowly, the toggle delay is about 2 seconds.
In CYCLIC SLEEP mode (AT+CFUN=7) during incoming voice call the CTS line continues to toggle.
GSM Power Saving Modes for Serial Devices
The H5 serial devices provide a function that reduces the power consumption when they are in IDLE state (waiting for a call), allowing a longer activity with a given battery capacity. You can configure the power saving function in several modes as needed.
To verify the power saving modes supported by your device, use the AT+CFUN=? command.
AT+CFUN=?
+CFUN: (0,1,2,4,5,7,9),(0)
OK
AT+CFUN=?
+CFUN: (0,1,2,4,5,7,9),(0, 1)
OK
AT+CFUN=?
+CFUN: (0,1,4,5,7),(0, 1)
OK
Legacy device.
Device supports all modes.
Device in the H5 family.
To select the power saving mode for your device, use the following AT Command:
AT+CFUN=[<fun>[,<rst>]]
Example
Check the current mode:
AT+CFUN?
+CFUN: 1
OK
CFUN = 1, device with full functionality and power saving disabled (factory setting)
SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide 22
CHAPTER 3 – SPECIFICATIONS
RTS Control of Power Mode AT+CFUN=9.
Device in power saving mode, this command forces the module to monitor the RTS control line indicating if the user application (DTE) is ready to receive data from the module (DCE):
RTS OFF: This condition causes the module (DCE) to power down its serial port and stays in CFUN=0 or CFUN=9 mode, in accordance with the entered command.
RTS ON: This condition causes the module (DCE) to power up its serial port and enters CFUN=1 mode (Normal
Operative Mode, factory setting).
DTR Control of Power Mode AT+CFUN=5
In CFUN=5 mode, the module monitors the DTR line, indicating if the user application (running on the DTE) is ready to operate:
DTR OFF: The module enters power saving mode (11- 20ma)
DTR ON: The module detects this control line condition and exits power saving mode.
In AT+CFUN=7 mode, the module forces CTS=OFF when it enters power saving mode. After exiting power saving mode, it forces CTS=ON.
CTS control line indicates permission from the DCE for the DTE to send data to the DCE. When the module is not ready to receive data (e.g.: commands) it ties up the CTS line, when it is ready to receive data it ties down the CTS line. The user application can monitor the CTS control line to check if the module is ready for commands, in accordance with V.24 Standard
Notes
When the module is powered ON the power saving function is disabled (CFUN=1, factory setting) in order to guarantee the data exchange between the H5 device and the user device; for this reason the CFUN mode command should be entered after every power up.
The protocol implementation of the module requires a delay between consecutive activation of CFUN=1 and
CFUN=4 (or vice versa) modes. It is suggested you use a delay of 10 sec.
The power saving function does not affect the network activity of the module. During the power saving mode the module remains registered on the network and reachable for incoming calls or SMS. If a call comes in during the power saving mode, the module will wake up and proceed normally with the unsolicited incoming call code.
Assume that the module is in power saving mode. The paging time range is 0.5 - 2.1 sec, depending on DRX time set by network. When the module wakes up from the power saving mode, it takes a maximum of 150 ms before checking the DTR line coming from the DTE. If a command is received during power saving, the module needs at least 0.5-2.1 sec +150 ms to be ready. Use a delay of at least 2250 ms between opening the port (DTR=ON) and sending commands.
23 SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide
CHAPTER 4 –DEVICE SPECIFIC REGULATORY INFORMATION
Chapter 4 – Device Specific Regulatory Information
The following is device specific FCC and Industry Canada information. For additional approval and regulatory information, see the Universal Socket Developer Guide.
FCC Part 15
FCC Identifier
Equipment Class
Notes
FCC Rule Parts
Approval
RI7HE910
Part 15 Class Computing Device Peripheral
WWAN Module
15B
Single Modular
FCC Grant Parts 22, 24, and 27
FCC Identifier
Equipment Class
Notes
Approval
RI7HE910
PCS Licensed Transmitter
WWAN Module
Single Modular
FCC Rule Parts Frequency Range (MHz) Output Watts Frequency Tolerance Emission Designators
22H
22H
22H
824.2 - 824.2
824.2 - 848.8
826.4 - 846.4
1.995
0.997
0.446
1.0 PM
1.0 PM
1.0 PM
300KGXW
300KG7W
4M20F9W
27
24E
24E
24E
1712.4 - 1752.6
1850.2 - 1909.8
1850.2 - 1909.8
1852.4 - 1907.6
0.226
0.993
0.38
0.243
1.0 PM
1.0 PM
1.0 PM
1.0 PM
4M20F9W
300KGXW
300KG7W
4M20F9W
Power listed is conducted. The maximum antenna gain including cable loss for compliance with radiated power limits, RF exposure requirements and the categorical exclusion requirements of 2.1091 is 5.22 dBi for part 22H,
3.31 dBi for part 24E and 6.45 dBi for part 27. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operated in conjunction with any antenna or transmitter not described under this FCC id, except in accordance with FCC multi-transmitter product procedures. The final product operating with this transmitter must include operating instructions and antenna installation instructions, for end-users and installers to satisfy RF exposure compliance requirements.
Compliance of this device in all final product configurations is the responsibility of the Grantee. Installation of this device into specific final products may require the submission of a Class II permissive change application containing data pertinent to RF Exposure, spurious emissions, ERP/EIRP, and host/module authentication, or new application if appropriate.
This device contains GSM functions that are not operational in the U.S. Territories. This filing is only applicable for
U.S. operations.
SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide 24
CHAPTER 4 –FCC AND INDUSTRY CANADA INFORMATION
Industry Canada
Certification Number/No. de Certification
5131A-HE910
Type of Radio Equipment/Genre de Matériel Advanced Wireless Services Equipment (1710-1755 MHz and
2110-2155 MHz) Cellular Mobile
GSM (824-849 MHz) Modular Approval PCS Mobile
(1850-1910 MHz)
Model/Modele
HE910
Specification/
Cahier des
Charges
RSS133
Issue/
Édition
5.0
RSS133
RSS132
RSS139
5.0
2.0
2.0
RSS133
RSS132
RSS132
5.0
2.0
2.0
From
Frequency/
De Fréquences
1.85 G
1.852 G
824.2 M
1.712 G
1.85 G
826.4 M
824.2 M
To
Frequency/
Á Fréquences
1.91 G
Emission Designation/
Designation
D’émission
241KGXW
Minimum Power Maximum
Power
1.908 G
848.8 M
1.753 G
4M09F9W
248KG7W
4M06F9W
993 mW
243 mW
997 mW
226 mW
993 mW
243 mW
997 mW
226 mW
1.91 G 252KG7W
846.4 M 4M07F9W
848.8 M 240KGXW
380 mW
446 mW
1.995 mW
380 mW
446 mW
1.995 mW
EMC, Safety, and R&TTE Directive Compliance
Hereby, MULTI-TECH SYSTEMS INC, declares that these SocketModem Cell and iCell HSPA+ modules are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
In order to satisfy the essential requirements of 1999/5/EC Directive, the module is compliant with the following standards:
RF spectrum use (R&TTE art. 3.2)
EMC (R&TTE art. 3.1b)
EN 301 511 V9.0.2
EN 301 908-1 V5.2.1
EN 301 908-2 V5.2.1
EN 300 440-2 V1.4.1
(1)
EN 301 489-1 V1.9.2
EN 301 489-3 V1.4.1
(1)
EN 301 489-7 V1.3.1
EN 301 489-24 V1.5.1
Health & Safety (R&TTE art. 3.1a) EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + AC:2011
EN 62311:2008
(1)
Only applicable to MTSMC-H5-MI-GP and MTSMC-H5-IP-GP product version.
25 SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide
CHAPTER 4 –DEVICE SPECIFIC REGULATORY INFORMATION
The conformity assessment procedure referred to in Article 10 and detailed in Annex IV of Directive 1995/5/EC has been followed with the involvement of the following Notified Body:
AT4 wireless, S.A.
Parque Tecnologico de Andalucía
C/ Severo Ochoa 2
295990 Campanillas – Málaga
SPAIN
Notified Body No: 1909
Thus, the following marking is included on the product:
There is no restriction for the commercialization of this device in all European Union countries.
The CE mark is affixed to this product to confirm compliance with the following European Community Directives:
Council Directive 2004/108/EC of 15 December 2004 on the approximation of the laws of Member States relating to electromagnetic compatibility; and
Council Directive 2006/95/EC of 12 December 2006 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits; and
Council Directive 1999/5/EC of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity.
SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide 26
CHAPTER 5 – CARRIER SPECIFIC INFORMATION
Chapter 5 – Carrier Specific Information
Notice for Devices that Use Aeris Radios
One component of your device is a radio. A radio algorithm prevents your device from repeatedly attempting to connect to the network when the radio:
cannot establish a packet data connection or
fails to access the application server.
When writing applications for your devices, ensure that your applications do not interfere with the radio's connection retry algorithm. If you fail to do so, Aeris might block network access for your devices.
After your devices reach the end of their commercial lifespan, you must remove them from the Aeris network. To do so, remove power from the devices and remove their antennas. If your devices continue to attempt to register with the network after you cancel device subscriptions, Aeris can bill you for any traffic generated by those devices.
27 SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide
Chapter 6 – Application Notes
CHAPTER 6 –APPLICATION NOTES
LED Interface
The LED signal indicates the SocketModem working status. Refer to the mechanical drawing for LED locations.
LED 1 – Heartbeat – IP and –GP Builds Only
LED 1 Signal Heartbeat LED
OFF No power to the unit.
Blinking Power on.
LED 2 – Link Status – All Builds
LED 2 Signal Link Status LED
OFF No power to the unit.
ON Continuously lit Powered and connected, but not transmitting or receiving.
Slow blink (-0.2Hz) Powered and searching for a connection.
Faster blink (-3Hz) Transmitting or receiving.
Note:
For non-IP builds, to ensure that the Link Status LED works properly, issue the following AT Command sequence to the GPIO:
AT#GPIO=1,0,2
AT#SLED=2
LED 3 – Signal Strength –IP and –GP Builds Only
LED 3 Signal Signal Strength LED
OFF No signal.
GSM
HSDPA
Blinking
+CSQ
99
99
The faster the LED blinks, the stronger the signal.
1.5 s flash +CSQ
GSM 5-10
HSDPA
600ms flash
GSM
HSDPA
200ms flash
GSM
4-10
+CSQ
11-20
11-20
+CSQ
21-31
HSDPA 21-31
SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide 28
CHAPTER 6 –APPLICATION NOTES
LED 4 – GPS Status – GP Builds
LED 4 Signal GPS Status LED
OFF No power to the unit.
ON Continuously lit
Blinking
Satellite not acquired.
Satellite acquired.
RF Performances
RF performances are compliant with the ETSI recommendation 05.05 and 11.10. The module’s radio transceiver meets the requirements of 3GPP Release 5 & 6. All values indicated are conducted.
Receiver Features
Category
GSM 850 Sensitivity
E-GSM 900 Sensitivity
DCS 1800 Sensitivity
PCS 1900 Sensitivity
UMTS Band I 2100 Sensitivity
UMTS Band II 1900 Sensitivity
UMTS Band V 850 Sensitivity
UMTS Band VI 800 Sensitivity
Description
< -109 dBm
< -106 dBm
< -105 dBm
< -105 dBm
< -109 dBm
< -108 dBm
< -110 dBm
< -110 dBm
Transmitter Features
Category
Maximum output power (GSM 850 / GSM 900)
Description
+32 dBm ± 1 dBm GSMK mode (class 4)
+27 dBm ± 1 dBm 8PSK mode (class E2)
Maximum output power (DCS 1800 / PCS 1900) +29 dBm ± 1 dBm GSMK mode (class 1)
+26 dBm ± 1 dBm 8PSK mode (class E2)
Maximum output power (UMTS Band II 1900, V 850, &VI 800) +23 dBm ± 1 dBm (class 3)
Maximum output power (UMTS Band I 2100) +23 dBm ± 1 dBm (class 3)
RF Connection and Antenna
The RF connector on the SocketModem is a UFL standard type. See the Universal Socket Developer Guide for antenna details.
29 SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide
Frequency Bands
Mode
GSM850
EGSM900
DCS1800
PCS1900
WCDMA850
(band V)
WCDMA900
(band VIII)
WCDMA1700
(band IV)
WCDMA1900
(band II)
WCDMA2100
(band I)
Freq. TX (MHz) Freq. RX (MHz) Channels
824.2- 848.8 869.2 - 893.8 128 - 251
890.0 - 914.8 935.0 - 959.8 0 - 124
880.2 - 889.8 925.2 - 934.8 975 - 1023
1710.2 - 1784.8 1805.2 - 1879.8 512 - 885
1850.2 - 1909.8 1930.2 - 1989.8 512 - 810
826.4 - 846.6
882.4 - 912.6
871.4 - 891.6
927.4 - 957.6
Tx: 4132 - 4233
Rx: 4357 - 4458
Tx: 2712 - 2863
Rx: 2937 - 3088
1710.4 - 1755.6 2112.4 - 2167.6 Tx: 1312 - 1513
Rx: 9662 - 9938
1852.4 - 1907.6 1932.4 - 1987.6 Tx: 9262 - 9538
Rx: 9662 - 9938
1922.4 - 1977.6 2112.4 - 2167.6 Tx: 9612 - 9888
Rx: 10562 - 10838
CHAPTER 6 –APPLICATION NOTES
TX - RX offset
45 MHz
45 MHz
45 MHz
95MHz
80MHz
45MHz
45MHz
400MHz
80MHz
190MHz
SocketModem Cell HSPA and SocketModem iCell HSPA MTSMC-H5 Device Guide 30
Завантажити
Реклама